Loading...
HomeMy WebLinkAboutPermit D09-250 - KEY BANK - REROOFKEY BANK REROOF 3434 S 152 ST D09 -250 Parcel No.: 0041000495 Address: 3434 S 152 ST TUKW Suite No: Tenant: Name: KEY BANK - REROOF Address: 3434 S 152 ST , TUKVVILA WA City Tukwila Owner: Name: KEY BANK OF WASHINGTON Address: C/0 FIRST AMER TAX VALUATN , PO BOX 560807 75356 Phone: Contact Person: Name: KIEL LUNSFORD Address: 8005 SE 28 ST , TUKWILA WA 98188 Phone: 206 510 -3605 Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Inspection Request Line: 206 - 431 -2451 Web site: http: / /www.ci.tukwila.wa.us Contractor: Name: BAYLEY CONSTRUCTION A GEN. PTNSHP Address: PO BOX 9004 , MERCER ISLAND, WA 98040 -9004 Phone: 206 - 621 -8884 Contractor License No: BAYLECG034JC DEVELOPMENT PERMIT Permit Number: D09 -250 Issue Date: 12/17/2009 Permit Expires On: 06/15/2010 Expiration Date: 12/31/2009 DESCRIPTION OF WORK: REMOVAL OF EXISTING ASPHALT SHINGLE ROOFING DOWN TO EXISTING SHEATHING. APPLY 40 LB FELT PAPER TO SHEATHING AND ICE & WATER SHEILD AS INDICATED . INSTALL GAF 50 YR ASPHALT SHINGLES AND REPLACE GUTTERS AS SHOWN. Value of Construction: $20,375.00 Fees Collected: $773.07 Type of Fire Protection: International Building Code Edition: 2006 Type of Construction: VB Occupancy per IBC: 0008 doc: IBC -10/06 * *continued on next page ** D09 -250 Printed: 12 -17 -2009 Public Works Activities: Channelization / Striping: N Curb Cut / Access / Sidewalk / CSS: N Permit Center Authorized Signature: Signature: Print Name: doc: IBC -10/06 City oftukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Inspection Request Line: 206 - 431 - 2451 Web site: http: / /wwwci.tukwila.wa.us Fire Loop Hydrant: N Number: 0 Size (Inches): 0 Flood Control Zone: Hauling: N Start Time: End Time: Land Altering: Volumes: Cut 0 c.y. Fill 0 c.y. Landscape Irrigation: Moving Oversize Load: Start Time: End Time: Sanitary Side Sewer: Sewer Main Extension: Private: Public: Storm Drainage: Street Use: Profit: N Non - Profit: N Water Main Extension: Private: Public: Water Meter: N Date: I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the perfo ce of wor q I amrithorj£d to sign and obtain this development permit. [ArkiLL7r,1 Permit Number: D09 -250 Issue Date: 12/17/2009 Permit Expires On: 06/15/2010 Date: i2/ 7 /v5 This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. D09 -250 Printed: 12 -17 -2009 Parcel No.: 0041000495 Address: Suite No: Tenant: doc: Cond -10/06 3434 S 152 ST TUKW KEY BANK - REROOF 1: ** *BUILDING DEPARTMENT CONDITIONS * ** • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us PERMIT CONDITIONS Permit Number: Status: Applied Date: Issue Date: D09 -250 ISSUED 11/25/2009 12/17/2009 2: No changes shall be made to the approved plans unless approved by the design professional in responsible charge and the Building Official. 3: All permits, inspection records, and approved plans shall be at the job site and available to the inspectors prior to start of any construction. These documents shall be maintained and made available until final inspection approval is granted. 4: All construction shall be done in conformance with the approved plans and the requirements of the International Building Code or International Residential Code, International Mechanical Code, Washington State Energy Code. 5: Prior to final inspection for this building permit, a copy of the roof membrane manufacturer's warranty certificate shall be provided to the building inspector. 6: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. * *continued on next page ** D09 -250 Printed: 12 -17 -2009 • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us I hereby certify that I have read these conditions and will comply with them as outlined. All provisions of law and this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provision of any other work construction or the performance of work. Signature: Print Name: k, tz Lu.vsr —�20 doc: Cond -10/06 D09 -250 /2 7/1) 9 Date: � i ordinances governing or local laws regulating Printed: 12 -17 -2009 CITY OF TUKWILA Community Development Department Public Works Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www.ci.tukwila.wa.us SITE LOCATION Site Address: 3434 S. 152nd St, Seattle, WA 98188 Tenant Name: KeyBank Property Owners Name: KeyBank Mailing Address: 2025 Ontario St., 4th Floor Name: Kiel Lunsford Mailing Address: 8005 SE 28th St. E -Mail Address: Kiel @Bayley.net Company Name: Bayley Construction Mailing Address: 8005 SE 28th St. Contact Person: Kiel Lunsford E - Mail Address: Kiel @Bayley.net Contractor Registration Number: BAYLECG0034JC Company Name: Jacobs Mailing Address: 250 E. Broad St., Suite 1150 Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. * *Please Print ** Contact Person: Pat Farrell E -Mail Address: Patrick.Farrell @ jacobs.com Company Name: Jacobs Mailing Address: 250 E. Broad St., Suite 1150 Contact Person: Pat Farrell E -Mail Address: Patrick.Farrell @jacobs.com H:Wpplcations\Por ms- Applications On Line\2009 Applications \1 -2009 - Permit Application.doc Revised: 1 -2009 bh PO -2) Building Permit No. Mechanical Permit No. Plumbing/Gas Permit No. Public Works Permit No. Project No. (For office use only) King Co Assessor's Tax No.: Suite Number: Floor: New Tenant: ❑ Yes ® ..No Cleveland, City CONTACT PERSON - who do we contact when your permit is ready to be issued Day Telephone: (206) 510 -3605 Mercer Island, WA 98040 City State Fax Number: ( 343 -7728 GENERAL CONTRACTOR INFORMATION — (Contractor Information for Mechanical (pg 4) for Plumbing and Gas Piping (pg 5)) Mercer Island, City State Day Telephone: (206) 510 -3605 Fax Number: (206) 343 -7728 Expiration Date: ARCHITECT OF RECORD - All plans must be wet stamped by Architect of Record Columbus, City State Day Telephone: (614) 437 -4300 Fax Number: (614) 437 -4304 ENGINEER OF RECORD - All plans must be wet stamped by Engineer of Record Columbus, WA. State City State Day Telephone: (614) 437 -4300 Fax Number: (614) 437 -4304 98188 Zip Zip WA 98040 Zip OH 43215 Zip OH 43215 Zip Page 1 of 6 • • BUILDING PERMIT INFORMATION - 206 - 431 -3670 Valuation of Project (contractor's bid price): $ 20,375 Existing Building Valuation: $ Scope of Work (please provide detailed information): Removal of existing asphalt shingle roofing down to existing Shea — h�� i •�s� . A pp H L-10119 .-e4 vPX fi0 5 hr -E1 ice A water 2s iral C A-F ay Phz� 1 1 - 6 t /j12.\ 4 ve 2 ► 3 Le �t H t'.v s 2 S Will there be new rack storage? ❑ Yes D.. No If yes, a separate permit and plan submittal will be required. Provide All Building Areas in Square Footage Below PLANNING DIVISION: Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) *For an Accessory dwelling, provide the following: Lot Area (sq ft): Floor area of principal dwelling: Floor area of accessory dwelling: *Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard: Compact: Handicap: Will there be a change in use? ❑ Yes ❑ No If "yes ", explain: FIRE PROTECTION/HAZARDOUS MATERIALS: ❑ Sprinklers ❑ Automatic Fire Alarm ❑ None ❑ Other (specify) Will there be storage or use of flammable, combustible or hazardous materials in the building? ❑ Yes ❑ No If `yes', attach list of materials and storage locations on a separate 8 -1 /2 "x 11 " paper including quantities and Material Safety Data Sheets. SEPTIC SYSTEM ❑ On -site Septic System — For on -site septic system, provide 2 copies of a current septic design approved by King County Health Department. H:\ApplicationsWorms- Applications On Line\2009 Applications \1 -2009 - Permit Application.doc Revised: 1 -2009 bh Page 2of6 Existing Interior Remodel Addition to Existing Structure New Type of Construction per IBC Type of Occupancy per IBC 1 Floor 2 Floor Floor Floors thru Basement Accessory Structure * Attached Garage Detached Garage Attached Carport Detached Carport Covered Deck Uncovered Deck • • BUILDING PERMIT INFORMATION - 206 - 431 -3670 Valuation of Project (contractor's bid price): $ 20,375 Existing Building Valuation: $ Scope of Work (please provide detailed information): Removal of existing asphalt shingle roofing down to existing Shea — h�� i •�s� . A pp H L-10119 .-e4 vPX fi0 5 hr -E1 ice A water 2s iral C A-F ay Phz� 1 1 - 6 t /j12.\ 4 ve 2 ► 3 Le �t H t'.v s 2 S Will there be new rack storage? ❑ Yes D.. No If yes, a separate permit and plan submittal will be required. Provide All Building Areas in Square Footage Below PLANNING DIVISION: Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) *For an Accessory dwelling, provide the following: Lot Area (sq ft): Floor area of principal dwelling: Floor area of accessory dwelling: *Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard: Compact: Handicap: Will there be a change in use? ❑ Yes ❑ No If "yes ", explain: FIRE PROTECTION/HAZARDOUS MATERIALS: ❑ Sprinklers ❑ Automatic Fire Alarm ❑ None ❑ Other (specify) Will there be storage or use of flammable, combustible or hazardous materials in the building? ❑ Yes ❑ No If `yes', attach list of materials and storage locations on a separate 8 -1 /2 "x 11 " paper including quantities and Material Safety Data Sheets. SEPTIC SYSTEM ❑ On -site Septic System — For on -site septic system, provide 2 copies of a current septic design approved by King County Health Department. H:\ApplicationsWorms- Applications On Line\2009 Applications \1 -2009 - Permit Application.doc Revised: 1 -2009 bh Page 2of6 • PERMIT APPLICATION NOTES — Applicable to all permits in this application Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. Building and Mechanical Permit The Building Official may grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). Plumbing Permit The Building Official may grant one extension of time for an additional period not exceeding 180 days. The extension shall be requested in writing and justifiable cause demonstrated. Section 103.4.3 Uniform Plumbing Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER O • AL Signature: Kiel L.nsfor Print Name: Mailing Address: 8005 SE 28th St I Date Application Accepted: u I ,J 1 0 H:\Applications\ Forms - Applications On Line \2009 Applications \1 -2009 - Permit Application.doc Revise& 1 -2009 bh Date Application Expires: • Date: / /p /Os Day Telephone: (206) 510 -3605 Mercer Island, WA 98040 City State Zip Staff Initials: Page 6 of 6 Parcel No.: 0041000495 Address: 3434 S 152 ST TUKW Suite No: Applicant: KEY BANK - REROOF Receipt No.: R09 -01905 Initials: JEM Payment Date: 11/25/2009 03:00 PM User ID: 1165 Balance: $0.00 Payee: KIEL G LUNSFORD TRANSACTION LIST: Type Method Descriptio Amount Payment Credit Crd VISA - Authorization No. 00501C ACCOUNT ITEM LIST: Description BUILDING - NONRES PLAN CHECK - NONRES STATE BUILDING SURCHARGE • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us Account Code Current Pmts 000.322.100 000.345.830 640.237.114 RECEIPT 773.07 Total: $773.07 • Permit Number: D09 -250 Status: PENDING Applied Date: 11/25/2009 Issue Date: Payment Amount: $773.07 465.80 302.77 4.50 PAYMENT RECEIVED doc: Receiot -06 Printed: 11 -25 -2009 COMMENTS: AA ( i l� A.-- f( " r .ej AC iq r o J f- j - C`I .g 6 ? WP L J (iJtr L/e , S ,r.A, f 1cPJ per ice__ ,.. A p nD 0 3 f Date C — . Special Instructions: Date Wanted: ,. a.m " Requester: __._ n 1 i A Project:], �f �/� J, /�' Type of ( , �� (I � Address: 3'431 S. (-c& f Date C — . Special Instructions: Date Wanted: ,. a.m " Requester: Phone No: INSPECTION RECORD Retain a copy with permit Doq- 2 S c) PERMIT NO. INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter #100, Tukwila, WA 98188 (206)431 -3670 Approved per applicable codes. EJ Corrections required prior to approval. I 1 �S - r Insp tor: ❑ $60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: Date: ti Timberline® Select 4OTM FILE COPY Permit No. PM -1 Plan review approval is subject to errors and omissions. Approval of construction documents does not authorize the violation of any adopted code or ordinance. Receipt of approved Field Cop wledged: By Date: City Of 1Ukwila BUILDING DIVISION . pop Sell Sheet TM SEPARATE PERMIT REQUIRED FOR: ti Mechanical Electrical Plumbing 'Gas Piping City of Tukwila BUILDING DIVISION E� IEWED FOR COMPLIANCE APPROVED DEC 0 1 2009 K C BUILDING � " Mwila G DIVISION REVISIONS No changes shall be made to the scope of work without prior approval of Tukwila Building Division NOTE: Revisions will require a new pI[ n F;lhm ttal and may include addit;onal �.r; .• f_ RECEIVED CITY OF TUKVVII.A NOV 2 7 2009 PERMIT CENTER Quality You Can Trust Since 1886... From North America's Largest Roofing Manufacturer bo`I -X50 Roofing Solutions: Why Use a System - Quality Shingles ,susii„06. Premium Architectural Shingles J! "Popular Choice For A Classic Wood Shake Look" The unique "Shadow Accent" effect results in maximum dimensionality and depth! (Featured nationwide except the Northeast) In the Northeast only,Timberline Select 40TM Shingles are produced with the unique "Color Tones" look, which results in a more highly contrasted appearance. for HOMEOWNERS for PROFESSIONALS Click image above to view Timberline 40 Shadow Accent shingles on a house. Click image above to view Timberline 40 Color Tones shingles on a house. • Popular Choice... Timberline® Select 40TM Shingles are 17% heavier and thicker *, promoting longer life and extended durability. • Fantastic Appearance...Featuring the distinctive Shadow AccentTM effect, resulting in a classic wood shake appearance. • Safer... Class A fire and wind ratings from Underwriters Laboratories — the highest ratings possible. • High Performance...Heavyweight design and extra - strong Micro Weave® Core make it a popular choice in the Timberline® Series — America's most popular architectural shingles! • Stays In Place...Dura Grip® adhesive seals each shingle tightly and reduces the risk of shingle blow -off. Shingles confidently warranted to withstand winds up to 80 mph!** • Peace Of Mind...40 - year ltd. transferable warranty with Smart Choice® Protection for the first five yearSnon-prorated material and Installation labor coverage)." • Perfect Finishing Touch...Use distinctive TIMBERTEX® Ridge Cap shingles(in the West, use PacificRIDGETM or Universal Ridge Cap Shingles; In the Southeast, use Universal Ridge Cap Shingles) • More Referrals... People will know that you're installing America's #1- selling laminated shingles! • Less Chance Of Call - Backs...Durable, wind resistant shingle offers superior (80 mph) ltd. wind warranty!** 'Versus Timberline® 30 shingles See ltd. warranty for complete coverage and restrictions Specifications for Timberline Select 4OTM • Heavyweight Design • 40 -Year Ltd. Transferable Warranty • Smart Choice® Protection for the first 5 years • 80 mph Ltd. Wind Warranty • Fiberglass Asphalt Shingle • Listed Class A Fire -UL 790 • Passes UL 997 Wind Test • Passes 110 mph Wind Test • Algae- EaterT'• Protection available in certain areas (check sample board for details) • CSA Al23.5 -98 • ASTM D7158, Class H • ASTM D3018 Type 1 • ASTM 03161 Type 1 • ASTM 03462" • Dade County Approved (select plants) • Meets Wisconsin Administrative Code • Texas Department Of Insurance • Approx 64 Pieces/Square (Metric) • Approx. 78 Pieces/Square (English) • 4 Bundles/Square • Approx. 256 Nads/Square (Metric) • Approx 312 Nails/Square (English) • 5 5/8" Exposure (Metric) • 5" Exposure (English) • Product is manufactured to meet or exceed ASTM 03462; values from subsequent testing may vary depending on storage conditions. For Distinctive Ridge Cap Shingles, use matching TIMBERTEX® or Paci1IcRIDGETm Ridge Cap Shingles Applies to Timberline Select 40 White Shingles Only. Fl 13 -1/4" x 39 -3/6° Metric 12" x 36- 15/16" English Timberline® Select 40TM shingles are available nationwide 1 I N Self- Adhered Roofing Underlayment For Premium Roof Leak Protection Description Grace Ice & Water Shield has been the premier self - adhesive underlayment product used in domestic roof protection under shingles for more than 20 years. It has performed in the critical areas under the most severe climatic conditions to protect against wind driven rain and the effects of ice dam build up beneath the shingles. Because of the unique properties of Grace Ice & Water Shield, these benefits are also applicable in its use under a wide range of metal roofing materials, on low and high slope designs. Grace Ice & Water Shield is a premier membrane composed of two waterproofing materials - an aggressive rubberized asphalt adhesive backed by a layer of high density cross laminated polyethylene. The rubberized asphalt surface is backed with a foldless release paper that protects its adhesive quality. During application, the release paper is easily removed, allowing the rubberized asphalt to bond tightly to the roof deck. In addition, embedded in the membrane is a "split- release on demand" feature called RIPCORD. The membrane is supplied in 20 metre rolls, 1 metre in width. etion.com gracec 4," Ot C f :ffet i ; Grace Ice & Water Shie Features and Benefits • Easy to Handle and Apply The self - adhesive membrane bonds firmly to the roof deck without heat or special adhesives. Water cannot seep under the membrane. Watertight seams are easily formed. RIPCORD is a unique, patented feature that makes Grace Ice & Water Shield easier to apply by giving the applicator "split - release on demand." Faster application of the membrane in the straight - aways, as well as ease of membrane positioning in detailed areas (valleys, around dormers, etc), are just some of the benefits. • Foldless Release Paper The foldless release paper provides multiple performance enhancements: fewer edge catches, 180° pull- back, ease of membrane cutting (single cuts) and membrane positioning, quicker one -man installs and, therefore, an easier, more productive release. OR ANCE APPROVED DEC 0 1 2009 Construction Products Property Value Test Method Color Gray -Black Thickness, Membrane 1.02 mm (40 mil) ASTM D3767 Method A Tensile Strength, Membrane 1720 kN /m (250 psi) ASTM D412 (Die C Modified) Elongation, Membrane 250% ASTM D412 (Die C Modified) Low Temperature Flexibility Adhesion to Plywood Unaffected @ -29 °C ( -20 °F) 525 N/m (3.0 lbs /in. width) ASTM D1970 ASTM D903 Permeance (max) 2.9 ng/m Pa (0.05 Perms) ASTM E96 Material Weight Installed (max) 1.3 kg /m (0.3 lb /ft ASTM D461 Features & Benefits Easy to Handle and Apply: The self adhesive membrane bonds firmly to the roof deck without heat or special adhesives. Water cannot seep under the membrane. Watertight seams are easily formed. RIPCORD is a unique, patented feature that makes Grace Ice & Water Shield easier to apply by giving the applicator a "split - release on demand." Faster application of the membrane in the straight - aways, as well as ease of membrane positioning in detailed areas (valleys, around dormers, etc), are just some of the benefits. PRODUCT DATA Roll Length Roll Width Roll Size Packaging Roll Weight Rolls per Pallet PERFORMANCE PROPERI'1ES Ice Dams Wind Driven Rain 22.9 m (75 ft) 914 mm (36 in.) 20.9m ft corrugated cartons 27.9 kg (61.4 lbs) 35 Water from melting snow over the heated portion of the house runs down the roof, It freezes at the cold eave and an ice dam begins to form preventing drainage. Sloped roofs are not waterproof. They protect structures by shedding rain water. Foldless Release Paper: The foldless release paper provides multiple performance enhancements: fewer edge catches, 180° pull -back, ease of membrane cutting (single cuts) and membrane positioning, quicker one -man installs and, therefore, an easier, more productive release. Aesthetically Pleasing: Unlike other forms of ice dam protection, Grace Ice & Water Shield is concealed by the finished roof- ing, preserving the architectural appearance of the roof. Seals Around Nails: The rubberized asphalt layer in 11.0 m (36 ft) 914 mm (36 in.)' 10.4 m (108 ft corrugated cartons 15.3 kg (33.6 lbs) 25 As the ice dam grows, water is trapped behind It and backs up under the shingles. Eventually It reaches the roof deck and leaks through, damaging the Interior of the structure. Storm driven winds can cause sloped roof coverings to lift. Ram can then be easay driven under the roof covering directly to the unprotected roof deck where ft causes leaks and damage to the Interior of the structure. Grace Ice & Water Shield seals around roofing nails, resisting leakage caused by water back- up behind ice dams, or from wind - driven rain. Dual Barrier Protection: Rubberized asphalt and poly- ethylene are combined to form two waterproofing barriers providing maximum protection. Membrane Will Not Crack, Dry Out or Rot: Grace Ice & Water Shield resists attacks from fungus and bacteria; maintaining its inte- grity for long lasting protection. Protects Under All Standard Sloped Roof Coverings: Grace Ice & Water Shield protects under slate, tile, cedar shakes or metal, as well as under conventional asphalt shingles. Slip Resistant Surface: Grace Ice & Water Shield has a slip resistant embossed surface to maximize traction and safety for applicators. Grace Ice & Water Shield resists this leakage because of the seal around the fasteners, ability to make watertight laps, and the membrane's bond to the deck. Grace Ice & Water Shield applied beneath the sloped roof covering helps prevent wrnd- dnven ram from entering the structure. Seals around nails or fasteners. Fully adheres to deck, resisting leaks from wind -driven rain or water backup due to ice dams. Proven Track Record: Grace Ice & Water Shield is the name brand in roofing underlayments with a 25 year track record of protecting roofs from ice dams and wind- driven rain. Reroofable: Unlike some granular surfaced membranes, Grace Ice & Water Shield will not adhere to the underside of the exposed roof covering. Grace Ice & Water Shield can be applied over the old Grace underlayment (except over Grace Basik ®) in retrofit applications, making reroofing easier, less costly (since there is no need for removing the existing underlayment), more durable and environmentally friendly (as the structural deck remains intact avoiding the need to purchase additional wood decking). Grace Technical Support: Grace Ice & Water Shield is backed by a team of local technical support personnel that help ensure every application goes smoothly. Guidelines for Use Grace Ice & Water Shield is used as an underlayment for sloped roofs to resist water penetration due to water back- up behind ice dams or wind - driven rain. Grace Ice & Water Shield also offers leak protection in trouble prone spots like valleys, skylights, protrusions and other flashing areas. Ice Dams Grace Ice & Water Shield should be used in conjunction with designs which minimize ice dam formation. In cold climates, it is particularly important to provide proper insulation and ventilation to reduce the size of ice dams and to avoid interior condensation. Cathedral ceilings must include ventilation between rafters to allow for air flow to a ridge vent. Well ventilated cold roof designs are particularly important in alpine regions to reduce the size of ice dams which could contribute to structural damage. Several variables will influence the height of ice dams and the membrane coverage required. 1. Climate - The annual snow fall will affect the amount of membrane needed. 2. Slope - On a low slope, ice dams will extend farther inward from the roof edge. 3. Overhang - A wide overhang will require more membrane to reach the appropriate point on the roof. 4. Insulation and Ventilation - A very well insulated building with a cold, well ventilated attic will have smaller ice dams. 5. Valleys - Any valleys formed by projections such as dormers or roof direction changes are likely to trap more snow and cause larger ice dams. 6. Exposure - A northern exposure or shaded areas will generally contribute to larger ice dams. While gutters may make it easier for an ice dam to start, large dams can occur on roofs with no gutters. Removing snow from a roof edge or installing heat cables may not prevent ice dam formation, but may shift the location of the ice dam. Under certain conditions, a dam can form at the edge of the remaining snow. Local building codes should be consulted for specific requirements. Installation Procedure Surface Preparation Install Grace Ice & Water Shield directly on a clean, dry, continuous structural deck. Some suitable deck materials include plywood, wood composition, wood plank, metal, concrete, or gypsum sheathing. Remove dust, dirt, loose nails, and old roofing materials. Protrusions from the deck area must be removed. Decks shall have no voids, damaged, or unsupported areas. Repair deck areas before installing the membrane. Prime concrete, masonry surfaces and Dens -Glass Gold® with Perm -A- Barrier® WB Primer. Prime wood composition and gypsum sheathing with Perm -A- Barrier WB Primer if adhesion is found to be marginal (refer to Technical Letter 12). Apply Perm -A- Barrier WB Primer at a rate of 6 -8 m (250 -350 ft /gal). Priming is not required for other suitable surfaces provided that they are clean and clry. Membrane Installation Apply Grace Ice & Water Shield only in fair weather when the air, roof deck, and membrane are at temperatures of 5 °C (40 °F) or higher. Apply roof covering material at temper- atures of 5 °C (40 °F) or higher. Cut the membrane into 3 -5 m (10 -15 ft) lengths and reroll loosely. Peel back 300 -600 mm (1 -2 ft) of release liner, align the membrane, and continue to peel the release liner from the membrane. Press the membrane in place with heavy hand pressure. Side laps must be a minimum of 90 mm (3.5 in.) and end laps a minimum of 150 mm (6 in.). For valley and ridge application, peel the release liner, center the sheet 1 over the valley or ridge, drape, and press it in place. Work from the center of the valley or ridge outward in each direction and start at the low point and work up the roof. Alternatively, starting with a full roll of membrane, unroll a 1 -2 m (3 -6 ft) piece of membrane leaving the release liner in place. Align the membrane and roll in the intended direction of membrane application. Carefully cut the release liner on top of the roll in the cross direction being careful not to cut the membrane. Peel back about 150 mm (6 in.) of the release liner in the opposite direction of the intended membrane application exposing the black adhesive. Hold the release liner with one hand and pull the roll along the deck with the release liner, leaving the applied membrane behind. Use the other hand to apply pressure on the top of the roll. Stop frequently to press the membrane in place with heavy hand pressure. When finished with the roll go back to the beginning, reroll and pull the remaining release paper from the material, finishing the installation. For successive membrane courses, align the edge of the release liner with the dashed line provided on the surface of the membrane to achieve the 90 mm (3.5 in.) side lap. Consistent with good roofing practice, install the membrane such that all laps shed water. Always work from the low point to the high point of the roof. Apply the membrane in valleys before the membrane is applied to the eaves. Following placement along the eaves, continue application of the membrane up the roof. The membrane may be installed either vertically or horizontally. Use smooth shank, electro- plated galvanized nails for fastening shingles to get the best seal. Hand nailing generally provides a better seal than power- activated nailing. If nailing of the membrane is necessary on steep slopes during hot weather, backnail and cover the nails by over- lapping with the next sheet. Extend the membrane on the roof deck above the highest expected level of water back- up from ice dams and above the highest expected level of snow and ice on the wall sheathing on vertical side walls (dormers) and vertical front walls for ice dam protection. Consider a double layer of membrane in critical areas, such as along the eaves or in valleys, in climates where severe ice dams are anticipated. Apply the membrane to the entire roof deck for wind -driven rain protection. Apply a new layer of Grace Ice & Water Shield directly over the old Grace underlayment in retrofit applications following the standard membrane applica- tion procedure. Place metal drip edges or wood starter shingles over the membrane. Precautions and Limitations • Slippery when wet or covered by frost. • Consistent with good roofing practice, always wear fall protection when working on a roof deck. • Release liners are slippery. Remove from work area immediately after membrane application. • Do not leave permanently exposed to sunlight. Cover within 30 days. • Do not fold over the roof edge unless the edge is pro - tected by a drip edge, gutter or other flashing material. • Do not install on the chamfered edges of wood plank. • Do not install directly on old roof coverings. • Certain product applications are prohibited in hot desert areas in the Southwestern United States. Check with your Grace Construction Products representative. • Check with the manufacturer of the metal roofing system for any special requirements when used under metal roofing. Do not install directly under roof coverings especially sensitive to corrosion, such as zinc, without providing proper ventilation. • Do not install under copper, Cor -Ten ®, or zinc metal roofing in high altitudes. These roofs can reach extremely high temperatures due to the low reflectivity, high absorption, and high conductivity of the metals. Use Grace Ultra for these roof types. Check with your Grace Construction Products representative. • Provide proper roof insulation and ventilation to help reduce ice dams and to minimize condensation. Grace Ice & Water Shield is an air and vapor barrier. • Repair holes, frshmouths, tears, and damage to membrane with a round patch of membrane extending past the damaged area 150 mm (6 in.) in all directions. If fasteners are removed leaving holes in the membrane, it must be patched. The membrane may not self -seal open fastener penetrations. • Do not install fasteners through the membrane over unsupported areas of the structural deck, such as over the joints between adjacent structural panels. • Due to its slight asphaltic odor, do not apply where the membrane is exposed to interior living space. Refer to product literature for more complete information. • Not compatible with EPDM; use Grace Ultra for tie -ins (refer to Technical Letter 5). • Not compatible with polysulfides, flexible PVC, or high concentrations of resin (pitch). For more information, refer to Technical Letter 5. Use Grace Ice & Water Shield on all of these You know the "danger zones" where most roof leaks happen. Protect those areas with Grace Ice & Water Shield, and you create a self - sealing barrier that neither melting snow nor wind - driven rain can penetrate through or travel beneath. It takes surprisingly little Grace Ice & Water Shield to make danger zones safe. It adds very little to the cost of a Rake Edge Confined Rake Edge Door Low Slope Area Eave Code Compliance Grace Ice & Water Shield meets the following standards: • Underwriters Laboratories Inc. Class A fire classification under fiber- glass shingles and Class C under organic felt shingles (per ASTM E108/UL 790) • Underwriters Laboratories Inc. Classified Sheathing Material Fire Resistance Classification with Roof Designs: P225, P227, P230, P237, P259, P508, P510, P512, P514, P701, P711,P717, P722, P723, P732, P734, P736, P742, P803, P814, P818,P824 Grace Ice & Water Shield' Skylight Valley Chimney Ridge • International Conference of Building Officials (ICBO -ES) Report No. 3997 • Southern Building Code Congress International (SBCCIPST & ESI) Report No. 941338 • Building Officials and Code Administrators (BOCA -ES) Evaluation Report No. 94 -33 • Miami -Dade County NOA 99- 1108.05 • Canadian Construction Materials Centre (CCMC) 12693 -R • U.S. Department of Housing and Urban Development (HUD) Materials Release 1056e • City of Los Angeles RR 25330 critical areas roofing job, but the benefits of using it are obvious ... and important. That's why it's an easy sell. The more danger zones a sloped roof has, the more sense it makes to use Grace Ice & Water Shield. It neutralizes the danger zones in a way felts can't. Hip Dormer Windows Grace Vycor Plus Self- Adhered Flashing Application Guidelines Grace Ultra Grace Ice & Water Shield* Grace Select Grace Basik* Desert Southwest United States e 0 0 O* Under Copper, Zinc or Cor -Ten® In High Altitude Climates • 0 Under Architectural Metal Roofs 0 0 0 Roofing In High Altitude /Alpine Region Premium Protection From Severe Ice Dams * 0 0 0 As A Vapor Barrier 0 e e 0 As A Temporary Roof (see product specific appropriate exposure guidelines) 0 0 0 0 GRACE UNDERLAYMENTS PRODUCT SELECTION MATRIX *For application on wood substrates only 0 Best 0 Good For Technical Assistance call toll free at 866 - 333 -3SBM (3726). Visit our web site at www.graceconstruction.com 0 Not Recommended W. R. Grace & Co.-Conn. 62 Whittemore Avenue Grace In. & Water Shield. Basik. Perm -A- Barrier and Vycor are registered trademarks and RIPCORD is a trademark of W. R. Grace & Co. -Conn. Cor -Ten is a registered trademark assigned to USX Corporation Dens -Glass Gold is a registered trademark of G-P Gypsum Corporation We hope the mformatioa here will be helpful. It is based on data and knowledge considered to be true and accurate and rs offered for the users' constdcranan, ravesnga ton and verification, but we do not warrant the results to be obtained Please read all statements, recommendations or suggestions in conjunction with our conditions of sale, which apply to all goods supplied by us. No statement, recommendation or suggestion is intended for any use which would infringe any patent or copyright. W. R. Grace & Co.-Coon., 62 Whittemore Avenue, Cambridge, MA 02140. In Canada, Grace Canada, Inc.. 294 Clements Road, West, Ajax, Ontario, Canada LIS 3C6. These products may be covered by patents or patents pending Copyright 2004. W. R. Grace & Co.-Conn. GIWS -0■07 Printed in USA IAI4 FA/L1/3M `a printed on recycled paper Construction Products • PERMIT COORD COPY PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER: D09 - 250 DATE: 11 -27 -09 PROJECT NAME: KEY BANK REROOF SITE ADDRESS: 3434 S 152 ST X Original Plan Submittal Response to Incomplete Letter # Response to Correction Letter # Revision # after Permit Issued DEPARTMENTS: ' l � B ding i Public Works Complete Comments: A_ k AVA Fire Prevention Structural DETERMINATION OF COMPLETENESS: (Tues., Thurs.) DUE DATE: Planning Division Permit Coordinator Incomplete ❑ Not Applicable 12 -01 -09 Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: TUES /THURS ROUTING: Please Route n Structural Review Required ❑ REVIEWER'S INITIALS: APPROVALS OR CORRECTIONS: 11 Approved Notation: REVIEWER'S INITIALS: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Documents/routing slip.doc 2 -28 -02 Approved with Conditions No further Review Required ❑ DATE: DUE DATE: 12 -29-09 Not Approved (attach comments) ❑ DATE: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: Bond Bond Company Name Bond Account Number Effective Date Expiration Date Cancel Date Impaired Date Bond Amount Received Date 2 SAFECO INS CO OF AMERICA 5890663 01/01/2002 Until Cancelled 12/31 /2000 ARCHIVED $12,000.00 12/06/2001 1 SAFECO INS CO 5890663 01/28/1997 01/01/2002 $6,000.00 License Name Type Specialty 1 Specialty 2 Effective Date Expiration Date Status ROBEREB375N0 ROBERT E BAYLEY CONSTR INC CONSTRUCTION CONTRACTOR GENERAL UNUSED 8/20/1963 12/31 /2000 ARCHIVED Name Role Effective Date Expiration Date BAYLEY KEY MEMBERS INC PARTNER 01/01/1980 BAYLEY HOLDINGS INC PARTNER 01/01/1980 Untitled Page General /Specialty Contractor • • A business registered as a construction contractor with Lftl to perform construction work within the scope of its specialty. A General or Specialty construction Contractor must maintain a surety bond or assignment of account and carry general liability insurance. Business and Licensing Information Name BAYLEY CONST A GEN UBI No. 601771879 PARTNRSHP Phone 2066218884 Status ACTIVE Address PO BOX 9004 License No. BAYLECG034JC Suite /Apt. License Type CONSTRUCTION CONTRACTOR City MERCER ISLAND Effective Date 4/3/1997 State WA Expiration 12/31/2011 Date Zip 980409004 Suspend Date County KING Specialty 1 GENERAL Business Type Partnership Specialty 2 UNUSED Parent Company her Associated Licenses Business Owner Information Bond Information Insurance Information I Insurancel Company Policy Number Effective Expiration Page 1 of 3 CancellImpaired Amount l Received https: // fortress .wa.gov /lni/bbip/Detail.aspx 12/1 7/2009 SPECIFICATIONS SECTION 05 5213 - PIPE AND TUBE RAILINGS (CONT.) D. PROVIDE ANCHORS AND OTHER COMPONENTS AS REQUIRED TO ATTACH TO STRUCTURE, MADE OF SAME MATERIALS AS RAILING COMPONENTS UNLESS OTHERWISE INDICATED; WHERE EXPOSED FASTENERS ARE UNAVOIDABLE PROVIDE FLUSH COUNTERSUNK FASTENERS. 1. FOR ANCHORAGE TO CONCRETE, PROVIDE INSERTS TO BE CAST INTO CONCRETE, FOR BOLTING ANCHORS. 2 FOR ANCHORAGE TO MASONRY, PROVIDE BRACKETS TO BE EMBEDDED IN MASONRY, FOR BOLTING ANCHORS. 3. FOR ANCHORAGE TO STUD WALLS. PROVIDE BACKING PLATES, FOR BOLTING ANCHORS. 4. POSTS: PROVIDE ADJUSTABLE FLANGED BRACKETS. E PROVIDE SLIP-0N NON -WELD MECHANICAL FITTINGS TO JOIN LENGTHS, SEAL OPEN ENDS, AND CONCEAL EXPOSED MOUNTING BOLTS AND NIIT5, INCLUDING BUT NOT LIMITED TO ELBOWS, TSHAPES, SPLICE CONNECTORS, FLANGES, ESCUTCHEONS, AND WALL BRACKETS. 203 ALUMINUM MATERIALS A ALUMINUM PIPE: SCHEDULE 40; ASTM B 429B 429M, ASTM B 241B 24154. OR ASTM B 483B 48354. NON -WELD MECHANICAL FITTINGS ( RUSH SET SCREWS). STRAIGHT SPLICE CONNECTORS. 2.04 ALUMINUM FINISHES A CLASS NATURAL ANODIZED FINISH: MAMA 611 AAM12C22A41 CLEAR ANODIC COATING NOT LESS THAN 0.7 MILS THICK B. CLASS !COLOR ANODIZED FINISH: MAMA 611 AA7Al2C22A42 INTEGRALLY COLORED ANODIC COATING NOT LESS THAN 0.7 MILS THK2C PART3 EXECUTION 101 PREPARATION A APPLY ONE COAT OF BITUMINOUS PAINT TO CONCEALED ALUMINUM SURFACES THAT WILL BE IN CONTACT WITH CEMENTRIOUS OR DISSIMILAR MATERIALS. 3.02 ERECTION TOLERANCES A MAXIMUM VARIATION FROM PLUMB, OFFSET FROM TRUE AUGNMENT AND OUT OF POSITION: 1/4 INCH SECTION 06 1000 - ROUGH CARPENTRY PART1 GENERAL 101 SECTION INCLUDES A STRUCTURAL DIMENSION LUMBER FRAMING, NON-STRUCTURAL DIMENSION LUMBER FRAMING, ROUGH OPENING FRAMING FOR DOORS, WINDOWS, AND ROOF OPENINGS, UNDERLAYMENT, ROOF - MOUNTED CURBS. ROOFING HAILERS, PRESERVATIVE TREATED W000 MATERIALS, FIRE RETARDANT TREATED WOOD MATERIALS, COMMUNICATIONS AND ELECTRICAL ROOM MOUNTING BOARDS, CONCEALED WOOD BLOCKING, NAILERS, FURRINGS, SUPPORTS AND GROUNDS. PART PRODUCTS 201 GENERAL REQUIREMENTS A DIMENSION LUMBER COMPLY WI H PS 20 AND REQUIREMENTS OF SPECIFIED GRADING AGENCIES. 1. SPECIES: DOUGLAS RR -ARCH. UNLESS OTHERWISE INDICATED. 2. GRADING AGENCY: ANY GRADING AGENCY WHOSE RULES ARE APPROVED BY THE BOARD OF REVIEW, AMERICAN LUMBER STANDARD COMMITTEE (W W WALSC.ORG) AND WHO PROVIDES GRADING SERVICE FOR THE SPECIES AND GRADE SPECIFIED, PROVIDE LUMBER STAMPED WITH GRADE MAR( UNLESS OTHERWISE INDICATED. B. LUMBER FABRICATED FROM OLD GROWTH TIMBER IS NOT PERMITTED. C. PROVIDE SUSTAINABLY HARVESTED WOOD; SEE SECTION 016000 FOR REQUIREMENTS D PROVIDE WOOD HARVESTED WITHIN A 500 MILE RADIUS OF THE PROJECT SITE FOR LOCALLYSOURCED PRODUCTS. 202 CONSTRUCTION PANELS A SUBFLOORING: APA RATED SHEATHING. 1. EXPOSURE CUSS: EXTERIOR 2. SPAN RATING: 32)16 INCHES. 3. THICKNESS: 3)5 INCH, NOMINAL B. WALL SHEATHING: APA STRUCTURAL I RATED SHEATHING, EXTERIOR EXPOSURE CLASS, AND AS FOLLOWS 1. SPAN RATING: 24,0. 2. THICKNESS: 1/2 INCH, NOMINAL C. WALL SHEATHING: PLYWOOD, PS I, GRADE C-0. EXPOSURE I. D COMMUNICATIONS AND ELECTRICAL ROOM MOUNTING BOARDS: INTERIOR GRADE, AO PLYWOOD ; 3/4 INCH THICK FLAME SPREAD INDEX OF 25 OR LESS, SMOTE DEVELOPED INDEX OF 450 OR LESS, WHEN TESTED IN ACCORDANCE WITH ASTM E 64. E. OTHER APPLICATIONS: 1. CONCEALED PLYWOOD. PS 1, CC PLUGGED. EXTERIOR GRADE 2. EXPOSED PLYWOOD: PS 1, A-0, INTERIOR GRADE 203 ACCESSORIES A FASTENERS AND ANCHORS: 1. METAL AND FINISH: HOT -DIPPED GALVANIZED STEEL PER ASTM A 153/A 15354 FOR HIGH HUMIDITY AND PRESERVATIVE- TREATED WOOD LOCATIONS, UNFINISHED STEEL ELSEWHERE. 2. DRYWALL SCREWS: BUGLE HEAD, HARDENED STEEL POWER DRIVEN TYPE, LENGTH THREE TIMES THICKNESS OF SHEATHING. 1 AN01065. TOGGLE BOLT TYPE FOR ANCHORAGE TO HOLLOW MASONRY. B. SUBFLOOR GLUE: WATERPROOF, WATER BASE, NR CURE TYPE, CARTRIDGE DISPENSED. 2.04 FACTORY WOOD TREATMENT A TREATED LUMBER AND PLYWOOD: COMPLY WITH REQUIREMENTS OF AWPA U1 - USE CATEGORY SYSTEM FOEW0000i TREATMENTS DETERMINED BY USE CATEGORIES. EXPECTED SERVICE CON0ITKNS, AND SPECIFIC APPLICATIONS. 1. FIRE - RETARDANT TREATED WOOD: MARK EACH PIECE OF WOOD WDH PRODUCERS STAMP INDICATING COMPUANCE WITH SPECIFIED REQUIREMENTS. 2. PRESERVATIVE- TREATED WOOD: PROVIDE LUMBER AND PLYWOOD MARKED OR STAMPED BY AN ALSC- ACCREDDED TESTING AGENCY, CERTIFYING LEVEL AND TYPE OF TREATMENT W ACCORDANCE WITH AWPA STANDARDS PART3 EXECUTION 3.51 BLOCKING, NATTERS, AND SUPPORTS A PROVIDE FRAMING AND BLOCKING MEMBERS AS INDICATED OR AS REQUIRED TO SUPPORT FINISHES, FIXTURES, SPECIALTY RESTS, AND TRIM B. IN METAL STUD WALLS, PROVIDE CONTINUOUS BLOCKING AROUND DOOR AND WINDOW OPENINGS FOR ANCHORAGE OF FRAMES, SECURELY ATTACHED TO STUD FRAMING. C. W WALLS, PROVIDE BLOCKING ATTACHED TO STUDS AS BACKING AND SUPPORT FOR WALL - MOUNTED RENS. UNLESS ITEM CAN BE SECURELY FASTENED TO IWO OR MORE STUDS OR OTHER METHOD OF SUPPORT I5 EXPLICITLY INDICATED. D SPECIFICALLY. PROVIDE THE FOLLOWING NONSTRUCTURAL FRAMING AND BLOCKING: 1. CABINETS AND SHELF SUPPORTS. WALL BRACKETS, HANDRAILS. GRAB BARS, TOILET ROOM ACCESSORIES, DOOR STOPS, WALL PANELNG AND TRIAL CHALKBOARDS, BULLETIN BOARDS AND MARKER BOARDS. 3.02 ROOF - RELATED CARPENTRY A COORDINATE INSTALLATION OF ROOFING CARPENTRY WITH DECK CONSTRUCTION, FRAMING OF ROOF OPENINGS, AND ROOFING ASSEMBLY INSTALLATION. B. PROVIDE PRESSURE TREATED WOOD CURBS AT ALL ROOF OPENINGS EXCEPT WHERE SPECIFICALLY INDICATED OTHERWISE. FORM CORNERS BY ALTERNATING LAPPING SIDE MEMBERS. SECTION 081000- ROUGH CARPENTRY (CONT.) 3.03 CLEANING A WASTE DISPOSAL COMPLY WITH THE REQUIREMENTS OF LOCAL BUILDING ORDINANCES. 1. COMPLY WITH APPLICABLE REGULATIONS. 2. DO NOT BURN SCRAP ON PROJECT SITE OR BURN SCRAPS THAT HAVE BEEN PRESSURE TREATED. 3. DO NOT SEND MATERIALS TREATED WITH PENTACHLOROPHENOL CCA OR ACA TO CO. GENERATION FACILITIES OR - WASTE -TO- ENERGY' FACILITIES. B DO NOT LEAVE ANY WOOD, SHAVINGS, SAWDUST, ETC. ON THE GROUND OR BURIED IN FILL C. PREVENT SAWDUST MID WOOD SHAVINGS FROM ENTERING THE STORM DRAINAGE SYSTEM. SECTION 06 2000 - FINISH CARPENTRY PMT GENERAL 1.01 SECTION INCLUDES A FINISH CARPENTRY ITEMS, WOOD DOOR FRAMES, GLAZED FRAMES, WOOD CASINGS AND MOLDINGS. 1.02 QUALITY ASSURANCE A GRADE MATERIALS IN ACCORDANCE WITH THE FOLLOWING 1. LUMBER GRADING AGENCY: CERTIFIED BY ALSC. 2. PLYWOOD: CERTIFIED BY THE AMERICAN PLYWOOD ASSOCIATION. 3. HARDWOOD LUMBER GRADING: NHU GRADING RULES. B FABRICATOR QUALIFICATIONS: COMPANY SPECIALIZING IN FABRICATING THE PRODUCTS SPECTRE) IN THIS SECTION WITH MINIMUM 5 YEARS OF DOCUMENTED EXPERIENCE 1.03 REGULATORY REQUIREMENTS A CONFORM TO APPLICABLE CODE FOR FIRE RETARDANT REQUIREMENTS. PART2 PRODUCTS 201 MATERIALS - GENERAL A UNLESS OTHERWISE INDICATED PROVIDE PRODUCTS OF OUALITY SPECIFIED BY AWI ARCHITECTURAL WOODWORK QUALITY STANDARDS ILLUSTRATED FOR PREMIUM GRADE 202 LUMBER MATERIALS A HARDWOOD LUMBER , SAWN, MAXDAUM MOISTURE CONTENT OF 6 PERCENT SURABLE FOR STAIN FINISH 203 SHEET MATERIALS A SOFTWOOD PLYWOOD EXPOSED TO VIEW: HARDWOOD FACE SPECIES AS INDICATED, PLAIN SAWN, VENEER CORE; PS 1 GRADE A-B; GLUE TYPE AS RECOMMENDED FOR APPLICATION. 204 ADHESIVE A ADHESIVE: TYPE RECOMMENDED BY LAMINATE MANUFACTURER TO SUR APPUCATION. 205 FASTENERS A FASTENERS: OF SIZE AND TYPE TO SUIT APPLICATION; FINISH AS INDICATED IN CONCEALED AND EXPOSED LOCATIONS. B. CONCEALED JOINT FASTENERS: THREADED STEEL. 2.06 ACCESSORIES A LUMBER FOR SHIMMING. BLOCKING.0. B. SAFETY GLASS: LAMINATED GLASS COMPLYING WITH 16 CFR 1201 AND ANSI Z97.1; CLEAR NOMINALLY 6 W4 THICK C. STAIN AND SATIN FIMSH: REFER 10 FINISH SCHEDULE D. WOOD FILLER SOLVENT BASE, TINTED TO MATCH SURFACE FINISH COLOR PART 3 EXECUTION 3.01 ERECTION TOLERANCES A MAXIMUM VARIATION FROM TRUE P050 06: 1/16 INCH. B. MAXIMUM OFFSET FROM TRUE ALIGNMENT WTM ABUT7WG MATERIALS 1/32 11401. SECTION 064100 - ARCHITECTURAL WOOD CASEWORK PART GENERAL 1.01 SECTION INCLUDES A SPECIALLY FABRICATED CABINET UNITS, COUNTERTOPS, CABINET HARDWARE,FACTORY FINISHING AND PREPARATION FOR INSTALLING UTILITIES. 1.02 QUALITY ASSURANCE A PERFORM WORK IN ACCORDANCE WITH AWOAWMAC ARCHITECTURAL WOODWORK QUALITY STANDARDS ILLUSTRATED. PREMIUM QUALITY. UNLESS OTHER QUALITY 15 INDICATED FOR SPECIFIC ITEMS. B. MANUFACTURER QUALIFICATIONS: COMPANY SPECIALIZING IN MANUFACTURING THE PRODUCTS SPECIFIED IN THIS SECTION WITH MINIMUM 5 YEARS OF DOCUMENTED EXPERIENCE. C. MANUFACTURER QUALIFICATIONS: MEMBER IN G000 STANDING OF THE ARCHITECTURAL WOODWORK INSTITUTE (AWL) OR THE ARCHITECTURAL WOODWORK MANUFACTURERS ASSOCIATION OF CANADA (AWTUC) AND FAMILIAR WITH THE AWIAWMAC OSI. D. QUALITY CERTIFICATION: PROVIDE INSPECTION AND QUALITY CERTIFICATION OF COMPLETED CUSTOM CABINETS IN ACCORDANCE WITH AWNAWMAC QUALITY CERTFCATION PROGRAM. PART2 PRODUCTS 2.01 MANUFACTURERS A AS PROVIDED BY OWNER B. SUBSTITUTIONS: SEE SECTION 016000 • PRODUCT REQUIREMENTS. 2.02 LUMBER MATERIALS A SOFTWOOD LUMBER NIST PS 20; GRADED IN ACCORDANCE WITH AWIAWMAC ARCHITECTURAL WOODWORK QUALITY STANDARDS ILLUSTRATED, GRADE 1I0101054; AVERAGE MOISTURE CONTENT OF 5-10 PERCENT. B. HARDWOOD LUMBER NHL/ GRADED IN ACCORDANCE WITH AW1AWMAC ARCHITECTURAL WOODWORK QUALITY STANDARDS ILLUSTRATED, GRADE II/CUSTOM: AVERAGE MOISTURE CONTENT OF 5-10 PERCENT 203 PANEL MATERIALS A SOFTWOOD FACED PLYWOOD: B. EXPOSED SURFACES: NIST PS 1: APA AA GRADE, PWNSU(ED REDWOOD FACE VENEER INTERIOR RATED ADHESIVES, CORE OF PARTICLEBOARD, MEDIUM DENSITY FIBERBOARD OR ENGINEERED COMBINATION, THICKNESS AS INDICATED, C HARDWOOD FACED PLYWOOD: HPVA HP -1; GRADED IN ACCORDANCE WTM AWIAWMAC ARCHITECTURAL WOODWORK QUALITY STANDARDS ILLUSTRATED, CORE OF PARTIC1E90AR0, MEDIUM DENSITY FIBERBOARD, STRAWBOARD, OR ENGINEERED COMBINATION; TYPE OF GLIB RECOMMENDED FOR SPECIFIC APPLICATION: THICKNESS AS REQUIRED: WITH FACE VENEER 0. PARTICLEBOARD: ANSI A208.1; MEDIUM DENSITY INDUSTRIAL TYPE AS SPECIFIED IN AWIAWMAC ARCHITECTURAL WOODWORK QUALITY STANDARDS ILLUSTRATED, COMPOSED OF WOOD CUPS BONDED WITH INTERIOR GRADE ADHESIVE UNDER HEAT AND PRESSURE; SANDED FACES: THICKNESS AS REQUIRED; USE FOR COMPONENTS INDICATED ON DRAWINGS. E MEDIUM DENSITY FIBERBOARD (MDFI ANSI A208.2 TYPE AS SPECIFIED IN AWL/AMMO ARCHITECTURAL WOODWORK QUALITY STANDARDS ILLUSTRATED; COMPOSED OF WOOD FIBERS PRESSURE BONDED WITH MOISTURE RESISTANT ADHESIVE TO SUIT APPLICATION; SANDED FACES; THICKNESS AS REWIRED. 1. USE FOR PANTED COMPONENTS AND CONCEALED COMPONENTS. F. HARDWOOD EDGE6ANDING: USE SOLID HARDWOOD 60076 I DING MATCHING SPECIES, COLOR GRAN, AND GRADE FOR EXPOSED PORTIONS OF CABINETRY. 2.04 LAMINATE MATERIALS A MANUFACTURERS: 1. WIL50NART INTERNATIONAL INC WWW WILSONART.COM. B. HIGH PRESSURE DECORATIVE LAMINATE MPG.): NEMA LD 3. TYPES AS RECOMMENDED FOR SPECIFIC APPUCATIONS AND AS FOLLOWS 1. HORIZONTAL SURFACES: HGS, 0.048 INCH NOMINAL THICKNESS, THROUGH COLOR COLORS AS SCHEDULED, FINISH AS SCHEDULED. 2. VERTICAL SURFACES: VG5, 0.028 1501 NOMINAL THICKNESS, THROUGH COLOR COLORS AS SCHEDULED, FINISH AS SCHEDULED. SECTION 06 4100 - ARCHREC1URAL WOOD CASEWORK (CONT.) 3. FLAME RETARDANT SURFACES: HGF, 0.048 INCH NOMINAL THICKNESS, THROUGH COLOR COLORS AS SCHEDULED, FINISH AS SCHEDULED. 4, CABINET LINER CTS, 0.020 INCH NOMINAL THICKNESS, THROUGH COLOR COLORS AS SCHEDULED, FINISH AS SCHEDULED. 205 ACCESSORIES A ADHESIVE: TYPE RECOMMENDED BY FABRICATOR TO SUIT APPLICATION. B. FASTENERS: SIZE AND TYPE TO SUIT APPLICATION, THREADED CONCEALED JOINT FASTENERS, AND GROMMETS. C. BOLTS, NUTS, WASHERS, LAGS, PINS, AND SCREWS: OF SIZE AND TYPE TO SUIT APPLICATION; GALVANIZED OR CHROME- PLATED FINISH IN CONCEALED LOCATIONS AND STAINLESS STEEL OR CHROME-PLATED FINISH IN EXPOSED LOCATIONS. 206 HARDWARE A HARDWARE BHMA A156.9, TYPES AS RECOMMENDED BY FABRICATOR FOR QUALITY GRADE SPECIFIED. B. ADJUSTABLE SHELF SUPPORTS' STANDARD SIDE - MOUNTED SYSTEM USING MULTIPLE HOLES FOR PIN SUPPORTS AND COORDINATED SELF RESTS, SATIN CHROME FINISH, FOR NOMINAL 1 INCH SPACING ADJUSTMENTS. C. DRAWER AND 0000 PULLS: V SHAPED WIRE PULL. STEEL WITH SATIN FINISH, 4 INCH CENTERS D. CABINET LOCKS: KEYED CYLINDER TWO KEYS PER LOCK STEEL WITH CHROME FINISH. E. CATCHES. F. DRAWER SLIDES: 1. TYPE: STANDARD EXTENSION. COMMERCIAL GRADE, SIDE MOUNTED, INTEGRAL STOP AND SELF CLOSING. G. HINGES: EUROPEAN STYLE CONCEALED SELF-CLOSING TYPE, STEEL WITH POLISHED FINISH. 207 SUE FINISHING MATERIALS A STAIN, SHELLAC. VARNISH AND FINISHING MATERIALS: AS INDICATED ON DRAWINGS AND SECTION 099000. B. FINISHING: SITE FINISHED AS SPECIFIED ON DRAWINGS AND SECTION 09 9000. PART 3 EXECUTION 3.01 ADJUSTING A ADJUST INSTALLED WORK 3.02 CLEANING A CLEAN CASEWORK COUNTERS, SHELVES, HARDWARE. FITTINGS, AND FIXTURES. SECTION 07 2100 - THERMAUSOUND INSULATION PART 1 GENERAL 1.01 SECTION INCLUDES A BOARD INSULATION AND 841700 AL VAPOR RETARDER AT CAVITY WALL CONSTRUCTION, PERIMETER FOUNDATION WALL, AND UNDERSIDE OF FLOOR SLABS, B. BATT INSULATION AND VAPOR RETARDER W EXTERIOR WALL, CEILING. AND ROOF CONSTRUCTION C. BATT INSULATION FOR FILLING PERIMETER WINDOW AND DOOR SHIM SPACES AND CREVICES IN EXTERIOR WALL AND ROOF. D. BATT/SOUND INSULATION FOR INTERIM WALLS. PART 2 PRODUCTS 201 MANUFACTURERS A INSULATOR: 1. OWENS CORNINGWWW OWENSCORMNG.00 2. CERTAINTEED CORPORATION- WWW.CERTAINTEED.COM 3. DOW CHEMICAL COMPANY- WWW.DOWSTYROFOAM.COM 4. SUBSTITUTIONS: SEE SECTION 01 600)- PRODUCT REW0EMENTS. 2.02 BOARD INSULATION MATERIALS A EXTRUDED POLYSTYRENE BOARD INSULATION ASTM C 578. TYPE X EXTRUDED POLYSTYRENE BOARD WITH EITHER NATURAL SKIN OR CUT CELL SURFACES; WITH TUE FOLLOWING CHARACTERISTICS: 1.RAME SPREAD INDEX 7508 LESS, WHEN TESTED W ACCORDANCE WITH ASTM E 84. 2 SMOKE DEVELOPED INDEX: 450 OR LESS. WHEN TESTED W ACCORDANCE WITH ASTM E 64. 3 BOARD THICKNESS: 1 -12 INCHES. B. POLYISOCYANURATE BOARD INSULATOR; RIGID CELLULAR FOAM, COMPLYING WITH ASTM C 1289; TYPE L ALUMINUM FOIL BOTH FACES; CLASS 1, NON- REINFORCED FOAL CORE 1. FLAME SPREAD INDEX 7508 LESS, WHEN TESTED W ACCORDANCE WITH ASTM E M. 2 SMOKE DEVELOPED D DEK 450 OR LESS, WHEN TESTED IN ACCORDANCE WITH ASTM E 84. 3. BOARD THICKNESS: 2INCH. 203 BATT INSULATION MATERIALS A BATT INSULATION: ASTM C 665; PREFORMED BATT; FRICTION FIT, CONFORMING TO THE FOLLOWING: 1.00MBUSTIBILITY: NONCOMBUSTIBLE WHEN TESTED IN ACCORDANCE WITH ASTM E 136, EXCEPT FOR FACING. IF ANY. 2. THICKNESS: INCH AS REQUIRED BY CODES AND INDICATED ON DRAWINGS. 3. FACING: UNFACED. 4 FACING: ALUMINUM FOIL, ONE SIDE SECTION 07 3113 - ASPHALT SHINGLES PART 1 GENERAL 1.01 SECTION INCLUDES A ASPHALT SHINGLE ROOFING, FLEXBLE SHEET MEMBRANES FOR EAVE PROTECTION, UNDERLAYMENT, AND VALLEY PROTECTION AND ASSOCIATED METAL FLASHINGS AND ACCESSORIES. 1.02 QUALITY ASSURANCE A PERFORM WORK IN ACCORDANCE WITH 211E RECOMMENDATIONS OF NRCA STEEP ROOFING MANUAL B. PRODUCTS REQUIRED TO COMELY WITH FORE RESISTANCE CRRBUA lA LISTED AND LABELED 1.03 ENVIRONMENTAL REQUIREMENTS A DO NOT INSTALL SHINGLES OR EAVE PROTECTION MEMBRANE WHEN SURFACE TEMPERATURES ARE BELOW 45 DEGREES F. 1.04 EXTRA MATERIALS A SEE SECTION 01 6000 - PRODUCT REQUIREMENTS, FOR ADDITIONAL PROVISIONS B. PROVIDE 405E OF EXTRA SHINGLES OF EACH COLOR SPECIFIED. PART2 PRODUCTS 201 SHINGLES A MANUFACTURERS: 1. GAF MATERIALS CORPORATION: WLNW.GAF.COM. 2. OVENS CORNING CORP: VWNV.OWENSCORNWG.COM. 3. SUBSTITUTIONS. SEE SECTION 016000 • PRODUCT REQUREMENTS B. ASPHALT SHINGLES' ASPHALT-COATED GLASS FELT, MINERAL GRANULE SURFACED, COMPLYING WITH ASTM D 3461 CLASS A FIRE RESISTANCE WITH MIN.4076 MANUFACTURERS WARRANTY. 1. SELFSEAIJNG TYPE, SQUARE. 034.0R TO BE SELECTED FROM MANUFACTURERS STANDARDS. 2.02 ACCESSORIES A NABS: STANDARD ROUND WIRE SHINGLE TYPE. OF HOT -DIPPED ZINC COATED STEEL 12 GAGE 0.105 INCH SHANK DIAMETER 3/8 INCH HEAD DIAMETER OF SUFFICIENT LENGTH TO PENETRATE THROUGH ROOF SHEATHING OR 314 INCH INTO ROOF SHEATHING OR DECKING B. STAPLES: STANDARD WIRE SHINGLE TYPE, OF HOT DIPPED LNC COATED STEEL 16 GAGE, 0.62 INCH DIAMETER 15/16 INCH CROWN WIDTH, OF SUFFICIENT LENGTH 70 PENETRATE THROUGH ROOF SHEATHING OR 314 INCH INTO ROOF SHEATHING OR 060K160. C. PLASTIC CEMENT: ASTM D 4586, ASPHALT ROOF CEMENT. SECTION 07 3113 - ASPHALT SHINGLES (CONT.( D. LAP CEMENT: FIBRATED CUTBACK ASRULLT TYPE, RECOMMENDED FOR USE IN APPLICATION OF UNDERLAYMENT, FREE OF TOXIC SOLVENTS. E RIDGE VENTS: PLASTIC, EXTRUDED WITH VENT OPENINGS THAT DO NOT PERMIT DIRECT WATER OR WEATHER ENTRY: FLANGED TO RECEIVE SHINGLES 203 METAL FLASHINGS A METAL 714541NGS: PROVIDE SHEET PETAL EAVE EDGE, GABLE EDGE, RIDGE, RIDGE VENTS, OPEN VALLEY FUSHWG. CHIMNEY FLASHING, DORMER FLASHING. AND OTHER FLASHING INDICATED. 1. FORM FLASHINGS TO PROFILES INDICATED ON DRAWINGS. PART 3 FECIMON 3.01 INSTALLATION - EAVE PROTECTION MEMBRANE A INSTALL EAVE PROTECTION MEMBRANE FROM EAVE EDGE TO MINIMUM 4 FT UP -SLOPE BEYOND INTERIOR FACE OF EXTERIOR WALL. B. APPLY 41NCH WIDE BAND OF PLASTIC CEMENT OVER DECK FLANGE OF EAVE EDGE FLASHINGS, AND EMBED MN 18 INCH WIDE STRIP OF EAVE PROTECTION MEMBRANE. PLACE STARTER STRIP WITH EAVE EDGE FLUSH WITH FACE OF FLASHINGS. SECURE IN PLACE. LAP ENDS MINIMUM 6INCHES. C. APPLY LAP CEMENT AT RATE OF APPROXIMATELY 1 154 GAL/103 SD. FT OVER STARTER STRIP. D. STARTING FROM LOWER EDGE OF 015015R STRIP, LAY ADDITIONAL 36 INCH WIDE STRIPS IN LAP CEMENT. TO PRODUCE A TWO PLY MEMBRANE. WEATHER LAP PLIES MINIMUM 19 INCHES AND NAIL W PLACE. LAP ENDS MINIMUM 6 INCHES. STAGGER END JOINTS OF EACH CONSECUTIVE PLY. 302 INSTALLATION • UNDERLAYMENT A AT ROOF SLOPES LESS THAN 4:12 INSTALL TWO LAYERS OF UNDERLAYMENT OVER ENTIRE ROOF AREA WITH ENDS AND EDGES WEATHER LAPPED MINIMUM 4 INCHES. STAGGER ENO LAPS OF EACH CONSECUTIVE LAYER. NAIL IN PLACE. B. ITEMS PROJECTING THROUGH OR MOUNTED ON ROOF: WEATHER UP AND SEAL WATERTIGHT WITH PLASTIC CEMENT. 303 INSTALLATION - METAL FLASHING AND ACCESSORIES A INSTALL FLASHINGS W ACCORDANCE WITH NRCA REQUIREMENTS. B. WEATHER LAP JOINTS MINIMUM 21NCHES AND SEAL WEATHER TIGHT WITH PLASTIC CEMENT. C. SECURE IN PLACE WITH NAILS AT 12 INCHES ON CENTER. CONCEAL FASTENINGS. D. ITEMS PROJECTING THROUGH OR MOUNTED ON ROOFING: FLASH AND SEAL WEATHER TIGHT WITH PU5T1C CEMENT. 3.04 INSTALLATION - SHINGLES A INSTALL SHINGLES IN ACCORDANCE WITH MANUFACTURER'S INSTRUCTIONS. 1. FASTEN INDIVIDUAL SHINGLES USING 2 NAILS PER SHINGLE, OR AS REWIRED BY CODE, WHICHEVER IS GREATER 2. FASTEN STRIP SHINGLES USING 4 NAGS PER STRIP. OR AS REQUIRED BY CODE, WHICHEVER IS GREATER B. PLACE SHINGLES IN STRAIGHT COURSING PATTERN WITH 51NCH WEATHER EXPOSURE TO PRODUCE OOLELE DOPINESS OVER FULL ROOF AREA PROVIDE DOUBLE COURSE OF SHINGLES AT EAVES. C. PROTECT FIRST COURSE OF SHINGLES 3/4 1601 BEYOND FASCIA BOARDS. D. EXTE140 SHINGLES 1/2 INCH BEYOND FACE OF GABLE EDGE FASCIA BOARDS. SECTION 07 5300 • EIASTOMERIC MEMBRANE ROOFING PART 1 GENERAL 101 SECTION INCLUDES A ELASFOMERIC ROOFING MEMBRANE, ADHERED CONVENTIONAL APPUCAT ON, FLAT AND TAPERED INSULATION, VAPOR RETARDER DECK SHEATHING. FLASHINGS, ROOF CANT STRIPS, STACK BOOTS, ROOFING EXPANSION JOINTS, AND WALKWAY PADS. 102 QUALITY ASSURANCE A PERFORM WORT( IN ACCORDANCE WITH NRCA ROOFING AND WATERPROOFING MANUAL AND MANUFACTURER'S INSTRUCTIONS B. MANUFACTURER WAUFICA1ONS: COMPANY SPECIALIZING IN MANUFACTURING THE PRODUCTS SPECIFIED IN THIS SECTION WITH MINIMUM 5 YEARS OF DOCUMENTED EXPERIENCE. C. APPUCATOR QUALIFICATIONS: COMPANY SPECIALIZING W PERFORMING THE WORK OF THIS SECTION WITH MINIMUM 5 YEARS DOCUMENTED EXPERIENCE AND APPROVED BY MANUFACTURER 103 ENVIRONMENTAL REQUIREMENTS A DO NOT APPLY ROOFING MEMBRANE DURING UNSUITABLE WEATHER 6. DO NOT APPLY ROOFING MEMBRANE WHEN AMBIENT TEMPERATURE IS BELOW 40 DEGREES F OR ABOVE 90 DEGREES F. C. DO NOT APPLY ROOFING MEMBRANE TO DAMP OR FROZEN DECK SURFACE OR WHEN PRECIPRATION I5 EXPECTED OR OCCURRING. D. DO NOT EXPOSE MATER/NS VULNERABLE TO WATER OR SUN DAMAGE IN QUANTITIES GREATER THAN CAN BE WEATHERPROOFED THE SAME DAY. 104 WARRANTY PART 2 PRODUCTS 201 MANUFACTURERS A EPDM MEMBRANE MATERIALS (60 MIL): 1. CARLISLE SYNTEC INCORPORATED: WWV/.CAPoJSLESYNTEC.COM 2. FIRESTONE BUILDING PRODUCTS CO WWW.FIRESTONEEPCOCON. 3. GENFLE5 ROOFING SYSTEMS: VAVW.GENFLEX.COM. 4. SUBSTRUTIONS: SEE SECTION 016000 - PRODUCT REQUIREMENTS. B. INSULATION: 1. GAF MATERIALS CORPORATION: *500.051.0554 . 2. DOW CHEMICAL CO WWW.DOW.COM. 3. OWENS CORNING CORP: WWW.OWENSCORNING.COM 4. SUBSTITUTIONS: SEE SECTION 016000 • PRODUCT REQUIREMENTS. 202 ROOFING - UNBALLASTEDA PIJC*IWNS A ELASTOMERIC MEMBRANE ROOFING: COMPLY WITH NRCA SPECIFICATION PATE OVER 1/2 DENS DECK SHEATHING AND RIGID INSULATION. B. ROOFING A:0E!BLY REOURE!E/TS: 1. ROOF COVERING EXTERNAL FIRE - RESISTANCE CLASSIFCATION: UL CUSS A 2 FACTORY MUTUAL CLASSIFICATION CLASS I AND WINDSTORM RESISTANCE OF I-90. W ACCORDANCE WITH FM DS 1 -28. 3. INSULATION THERMAL VALUE (R), MINOJUMAS REQUIRED BY BUILDING CODES. C. ACCEPTABLE INSULATION TYPES • CONSTANT THICKNESS APPLICATION. AIY OF THE TYPES SPECIFIED. 1. MINIMUM 2 LAYERS OF POLYISOCYANURATE BOARD. 203 ACCESSORIES A STACK BOOTS. PREFABNICA TELL FLEXIBLE 6001 AND COLLAR FOR PPE STACKS THROUGH MEMBRANE; SANE MATERIAL AS MEMBRANE B. CANT AND EDGE STRIPS: WOOD FIBERBOARD. COMPATIBLE WITH ROOFING MATERIALS; CANTS FORMED T045 DEGREE ANGLE. C. SHEATHING ADHESIVE NONCOMBUSTIBLE TYPE FOR ADHERING GYPSUM SHEATHING TO METAL DECK D. SHEATHING JOINT TAPE PAPER TYPE. SELF ADHERING. E INSULATION JOINT TAPE GLASS FIBER REINFORCED TYPE AS RECOMMENDED BY INSULATION MANUFACTURER COMPATIBLE WITH ROOFING MATERIALS; 6 INCHES WIDE; SELF ADHERING. F. IN5IAATION FASTENERS: APPROPRIATE FOR PURPOSE INTENDED AND APPROVED BY ROOFING MANUFACTURER G. MEMBRANE ADHESIVE: AS RECOMMENDED BY MEMBRANE MANUFACTURER H. SURFACE CONDITIONER FOR ADHESIVES. COMPATIBLE WITH MEMBRANE AND ADHESIVES. I WSIIUTION ADHESIVE AS RECOMMENDED BY INSULATION MANUFACTURER. J. ROOFING NAILS: NON- FERROUS TYPE, SIZE AND CONFIGURATION AS REWIRED TD 5117 APPLICATION. K STRIP REGLET DEVICES: GALVANIZED STEEL MAXIMUM Pr/SSwl F LENGTHS PER LOCATION WITH ATTACHMENT FLANGES. L SEALANTS: AS RECOMMENDED BY MEMBRANE MANUFACTURER SECTION 07 5300 - ELASTOMERC MEMBRANE ROOFING (CONT.) PART3 EXECUTION 3.01 FIELD QUALITY CONTROL A SEE SECTION 01 4000 - QUALITY REQUIREMENTS, FOR GENERAL REQUIREMENTS FOR FIELD QUALITY CONTROL AND INSPECTION. B. REQUIRE SITE ATTENDANCE OF ROOFING AND INSULATION MATERIAL MANUFACTURERS DAILY DURING INSTALLATION OF THE WORK 302 CLEANING A REMOVE BITUMINOUS MARKINGS FROM FINISHED SURFACES. B. W AREAS WHERE FINISHED SURFACES ARE SOILED BY WORK OF THIS SECTION, CONSULT MANUFACTURER OF SURFACES FOR CLEANING ADVICE AND CONFORM TO THEIR DOCUMENTED INSTRUCTIONS. C. REPAIR OR REPLACE DEFACED OR DAMAGED FINISHES CAUSED BY WORK OF THIS SECTION. 3.03 PROTECTION OF FINISHED WORT( SECTION 07 6200- SHEET METAL FLASHING AND TRIM PART1 GENERAL 1.01 SECTION INCLUDES A FABRICATED SHEET METAL REM5, INCLUDING FU5HINGS. COUNTER FLASHINGS, GUTTERS. DOWNSPOUTS, SHEET METAL ROOFING, AND OTHER REAS INDICATED IN SCHEDULE, REGLETS AND PRECAST CONCRETE SPLASH PADS. 102 QUALITY ASSURANCE A PERFORM WORT( IN ACCORDANCE WITH SMACNA ARCHITECTURAL SHEET METAL MANUAL REQUIREMENTS AND STANDARD DETAILS, EXCEPT AS OTHERWISE INDICATED. B. FABRICATOR AND INSTALLER QUALIFICATIONS COMPANY SPECIALIZING IN SHEET METAL WORK WITH 5 YEARS OF DOCUMENTED EXPERIENCE PART PRODUCTS 201 SHEET MATERIALS A PRE-FINISHED GALVANIZED STEEL ASTM A 653AA 653M, WITH 0980215 ZINC COATING; MINIMUM 0.02 INCH THICK BASE METAL SHOP PRECOATED WITH MODIFIED SILICONE COATING. 1. MODIFED SIUCONE POLYESTER COATING: PIGMENTED ORGANIC COATING SYSTEM. MAMA 2603; BAKED ENAMEL FINSH SYSTEM; 00.06 AS SCHEDULED B. ALUMINUM ASTM B 209 (75TM B 20954(/ 0.032 INCH THICK; ANODIZED FINISH OF 00106 AS SELECTED. C. PRE-FINISHED ALUMINUM: ASR/ B 209 (/5751 B 209M); 0.032 INCH THICK PLAIN FINISH SHOP PRE COATED WITH FLUOROPOLYMER COATING OF COLOR AS SELECTED. 1. FLUOROPOLYMER COATING: HIGH PERFORMANCE ORGANIC FINISH, AMU 2604; MULTIPLE COAT, THERMALLY CURED FLUOROPOLYMER FINISH SYSTEM: COLOR AS SCHEDULED. 202 ACCESSORIES A FASTENERS: GALVANIZED STEEL WITH SOFT NEOPRENE WASHERS. PRIMER ZINC CHROMATE TYPE. SEALANT: SPECIFIED IN SECTION 079005, PLASTIC CEMENT: ASTM D 4586, TYPE 1, REGLET9: SURFACE MOUNTED GALVANIZED STEEL, SOLDER: ASTM 6 32 203 GUTTER AND DOWNSPOUT FABRICATION A GUTTERS: SMACNA ARCHITECTURAL SHEET METAL MANUAL, RECTANGULAR PROFILE B. DOWNSPOUTS: RECTANGULAR PROFILE. C. GUTTERS AND DOWNSPOUTS: SIZE FOR RAINFALL INTENSITY DETERMINED BY A STORM OCCURRENCE OF 1 IN 5 YEARS IN ACCORDANCE WITH MAGNA ARCHITECTURAL SHEET METAL MANUAL. D. ACCESSORIES: PROFILED TO SUIT GUTTERS AND DOWNSPOUTS. 1. GUTTER SUPPORTS: BRACKETS. 2 DOWNSPOUT SUPPORTS: BRACKETS. E. SPLASH PADS: PRECAST CONCRETE TYPE, OF SIZE AND PROFILES INDICATED; MINIMUM 3000 MAT 28 DAYS. WITH 54)534 M 5 PERCENT AIR ENTRAINMENT F. DOWNSPOUT BOOTS: PLASTIC. G. SEA METAL JOINTS. SECTION 07 8400 - FIRESTOPPING PART 1 GENERAL 1 01 SECTION INCLUDES A FIRESTOPPING MAIERULS. B. FIRESTOPPING OF ALL PENETRATIONS AND INTERRUPTIONS TO FIRE RATED ASSEMBLIES, WHETHER INDICATED ON DRAWINGS OR NOT, AND OTHER OPENINGS INDICATED. 1 02 QUALITY ASSURANCE A FIRE TESTING: PROVIDE FIRESTOPPING ASSEMBUES OF DESIGNS WHICH PROVIDE THE SCHEDULED FIRE RATINGS WHEN TESTED IN ACCORDANCE WITH METHODS INDICATED. 1 LISTING IN TIE CURRENT -YEAR CLASSIFICATION OR CERTIFICATION BOOKS OF UL FM, OR ITS (WARNOCK HERSEY) WILL BE CONSIDERED AS CONSTITUTING AN ACCEPTABLE TEST REPORT. 2 SUBMISSION OF ACTUAL TEST REPORTS IS REQUIRED FOR ASSEMBLIES FOR VOUCH NONE OF THE ABOVE SUBSTANTIATION EXISTS. B. MANUFACTURER QUALIFICATIONS: COMPANY SPECULQNG IN MANUFACTURING THE PRODUCTS SPECIFIED IN THIS SECTOR 11TH MINIMUM 5 YEARS DOCUMENTED EXPERIENCE C. INSTALLER OW WFICATIONS COMPANY SPECIAUZING W PERFORMING THE WORK OF THUS BECTON AND 1 APPROVED BY FACTORY MUTUAL RESEARCH UNDER FM STANDARD 4991. APPROVAL OF FIRESTOP CONTRACTORS. 2 WITH MINIMUM 3 YEARS DOCUMENTED EXPERIENCE INSTAWNG WORK OF THIS TYPE. 3. ABLE TO SHOW AT LEAST 5 SATISFACTORILY COMPLETED PROJECTS OF COMPARABLE SIZE AND TYPE. 4. APPROVED BY FIRESTOPPING MANUFACTURER. D. INSTALLING MECHANICS QUALIFICATIONS: TRAINED BY RRESTO7PING MANUFACTURER AND ABLE TO PROVIDE EVIDENCE THEREOF PART 2 PRODUCTS 2.01 FRESTOPPING 555516L ES A FIRESTOPPING: ANY MATERIAL MEETING REQUIREMENTS. t . FIRE RATINGS: SEE DRAWINGS FOR REQUIRED SYSTEMS AND RATINGS B. FIRESTOPPING AT UNINEULATED METALLIC PIPE MD CONDUIT PENETRATIONS, OF DIAMETER 4 INCHES OR LESS. ANY MATERIAL MEETING REQUIREMENTS. C. FIRESTOPPING AT COMBUSTIBLE PPE AND CONDUIT PENETRATIONS, OF DIAMETER 4 INCHES OR LESS: ANY MATERIAL MEETING REQUIREMENTS. D. 181570 RNG AT UNINSULATED METALLIC PIPE AND CONDUIT PENETRATIONS. OF DIAMETER 4 INCHES OR LESS: ANY MATERIAL MEETING REQUIREMENTS. E FIRESTOPPING AT CABLE TRAY PENETRATIONS: ANY MATERIAL MEETING REQUIREMENTS. F. 1RESTOPPING AT CABLE PENETRATIONS, NOT IN CONDUIT OR CABLE TRAY: CAULK OR PUTTY, G. FIRESTOPPING AT CONTROL JOINTS (WITHOUT PENETRATIONS): ANY MATERIAL MEETING REWIREMENI5. H. FIRESTOPPING BETWEEN EDGE OF FLOOR SUB AND CURTAIN WAIL (WITHOUT P60451 110505 GLASS FIBER OR MINERAL FIBER S4F4NG W0UUTION. 202 MATERIALS A FIRESTOPPING SEALANTS: PROVIDE ONLY PRODUCTS HAVING LOWER VOLATILE ORGANIC COMPOUND (AC) CONTENT THAN REQUIRED BY SOUTH COAST AIR QUALITY MANAGEMENT DISTRICT RULE 60.1168 B. EIASTOMERIC SIUCONE FIRESTOPPING: SINGLE COMPONENT SIUCONE ELASTOMERIC COMPOUND AND COMPATIBLE SIUCONE SEALANT C. FOAM FIRESTOPPPING: SINGLE COMPONENT FOAM COMPOUND D. FIBER COMPOUND FIRESTOPPING. FORMULATED COMPOUND MIXED WITH INCOMBUSTIBLE NON-ASBESTOS RBERSi E PEER FWESTOP MINERAL FIBER INSUATION USED N COMLUNCTION WITH ELASTOMERC SURFACE SEALER FORMING NRTGNT BOND TO OPENING. DISCLAIMER: NOT ALL SPECIFICATION SECTIONS APPLY TO THIS LOCATION. JACOBS 250 E. BROAD ST., SURE 1150, COLUMBUS, OH 43215 (614) 437.4300 FAX (614) 437-4304 REVIEWED FOR CODECOMPLIANCE- APPROVED DEC 0 1 20U9 City ofct kwiIa BUILDING DIVIQInn' RECEIVED CITY OF TUKVVI ILA NOV 2 7 2009 PERMIT CENTER Client: 0 KeyBank 2025 ONTARIO ST, 4TH FLOOR CLEVELAND, OHIO 44115 Project: 2008 BRANCH MODERNIZATION PROGRAM PID# 3872 RIVERTON HEIGHTS 3434 SOUTH 152ND ST. SEATTLE, WA 98188 No. 0 B A Date 06-25 -09 05-05-09 04 -09-09 Designed By: PDX Issue/Revision ISSUE FOR CONSTRUCTION ISSUE FOR PERMIT BID DESIGN DEVELOPMENT Drawn By KAH Checked By: MKS Project No.: F5W86602 Scale; AS NOTED Sheet Title; SPECIFICATIONS b0°I - 2S1) Drawing No.: G -103 _ANDS OF HAWLE" E'd'ER.R!SES, INC. PARCEL NG. 00 KNC CC. F.C.S NO. 2000021 ASPHALT S. 152ND STREET (50' PUBLIC RIGHT —OF —WAY) O ARCHITECTURAL SITE PLAN 1 SCALE 1,22 P.O.B. SURVEYOR'S DESCRIPTION GENERAL NOTES O SHEET KEYNOTES 1. ALL NOTES ARE FOR REFETWCE ONLY MESS NOTED 1. EGSTING ArrPSSOI F PARKING SPACE 0111ERIMSE, 2. SIGNS ARE TO BE INSTALLED BY LICENSED SIGN CONTRACTOR UNDER A SEPARATE SIGN PERMIT. / O oi 50. / / REVIEvvED FOR CODE COMPLIANCE APPPAvFD DEC ( hug City of Tukwila BUILDING oImInN 0 10' 20' 40' 60' NORTH SCALE 1'= 20' JAC 250 E. BROAD ST., SURE 1150, COLUMBUS, OH 43215 (614) 437-4300 FAX (614) 437-4304 RECEIVED CITY OF TUKI ILA NOV 2 7 2009 PERMIT CENTER Client: 0, KeyBank 2025 ONTARIO ST, 4TH FLOOR CLEVELAND, OHIO 44115 Project: 2008 BRANCH MODERNIZATION PROGRAM PI D# 3872 RIVERTON HEIGHTS 3434 SOUTH 152ND ST. SEATTLE, WA 98188 No. 0 B A Date 06-25-09 04-09.09 Designed By: PDX Issue /Revision ISSUE FOR CONSTRUCTION 05-05-09 ISSUE FOR PERMIT / BID DESIGN DEVELOPMENT Drawn By: KAH Checked By: MKB Project No.: F5W86602 Scale: AS NOTED Sheet Title: ARCHITECTURAL SITE PLAN Drawing No.: AS -100 mom ........•••••••rnmenamammum C) SOUTH-ELEVATION SCALE 1 /13 GRACE ICE AND WATER SHIELD FULL ROLL-TO EMEND MINDAUM OF 4 GUTTER EDGE EXLSTING ROOF SHEATHING .040 KUMINUM BOX GLTTER VERIFY SIZE 64 RELD, GUTTER TO 86 07280 TO BE SUPPORTED BY GUTTER FORM AND SHALL NOT SAG FINISH 70 66 (MK BRONZE. Danko BOX GUTTER FORM, REPLACE AS NECESSARY AND UNE WITH GRACE ICE AND WATERSHIELD P6105 10 INSTALLATION OF GLTTIER NORTH-ELEVATION C) GUTTER DETAIL SCALE 1 NEW SHINGLES GRACE ICE AND WATER SHIELD EXTEND FROM GUTTER OVER DRIP EDGE A MINIMUM Of 640 AUJMINUM DRIP EDGE FINISH KYNAR 500004110 OUTUNE OF EOSTING FASCIA GUTTER DROP TO EXTEND FULL LENGTH REQUIRED TO BE SINGLE PIECE FROM GUTTER TO DOWN SPOUT DIFFI MINUMIN OVER LAP AT DOWNSPOUT TO BE 4. DROP TO BE FORMED WITH PITTSBURGH LOCK AND SEALED TO BE WATER norm O EAST-ELEVATION SCALE tre WEST - ELEVATION SCALE: irr-v-o• GENERAL SHEET NOTES 1. ALL DITERIOR BRICK SURFACE SHALL BE PRESSURE WASHED W/ REQUIRED SCIVENTS. 0 SIGNS ARE TO PE INSTALLED BY UCENSED SIGN CONTRACTOR UNDER A SEPARATE SIGN PERMIT. 0 SHEET KEYNOTES 1. NEW IN-UNE LED SIGNAGE 0 NEW .040 ALUMINUM BOX GUTTER SEE DETAIL 6/A.201 3. NEW SURROUND *7 *164 4. NEW DIMENSIONAL SHINGLE ROOF-COLOR COOL BARKWOOD-COLOR 70 88 CONRRMF_D BY KEY BANK ASSUME FULL TEAR OFF, CONTRACTOR TO DISPOSE OF SH 6. APPLY WINDOW FRAI TO INTERIOR SIDE OF EXISTING WINDOW GLAZING. REFER TO SSORES UNDER SPECIFICATIONS SECTION 04 8, GLAZING 7. POWER WASH aTERIOR BRICK A 11. NEW .032 ALUMINUM DOWNSPOUT SIZE TO MATCH COSTING, FINISHED KYNAR 500 DARK BRON:a REVIEWED FOR CODE COMPLIANCE APDanvED DEC 0 1 2H9 City of Tukwila BUILDING DIVISION - ••■•••••• JACOBS 250 E. BROAD ST., SUITE 1150, COWMBUS, OH 43215 (614) 437-4300 FAX (614) 4374304 Client . RECEIVED CITY OF TUKWILA NOV ?72009 • KeyBank 2025 ONTARIO ST, 4TH FLOOR CLEVELAND, OHIO 44115 Project: 2008 BRANCH MODERNIZATION PROGRAM PID# 3872 RIVERTON HEIGHTS 3434 SOUTH 152ND ST. SEATTLE, WA 98188 No. 1 0 Date 06-19-09 06-25-09 Designed By: PDX Issue/Revision PERMIT COMMENT ISSUE FOR CONSTRUCTION 13 I 05-05-09 ISSUE FOR PERMIT /BID A 104-09-09 I DESIGN DEVELOPMENT • Drawn By: KAH Checked By: MKB Project No. F5W86602 Scale: AS NOTED Sheet Title: EXTERIOR ELEVATIONS Drawing No.: A-201