Loading...
HomeMy WebLinkAboutPermit D09-262 - CASCADE CONTAINERS - CLEARWIRECASCADE CONTAINERS CLEARWIRE 1231 ANDOVER PK W D09 -262 Parcel No.: 3523049074 Address: 1231 ANDOVER PK W TUKW Suite No: City of Tukwila Tenant: Name: CASCADE CONTAINERS - CLEARWIRE Address: 1231 ANDOVER PK W , TUKWILA WA Owner: Name: KMBR LLC B % CASCADE CONTAI Address: 1232 ANDOVER PARK W , TUKWILA WA 98188 Phone: Contact Person: Name: TODD GERRISH Address: 8760 122 AV NE , KIRKLAND WA 98033 Phone: 206 498 -6891 Contractor: Name: BOSS CONSTRUCTION SERVICES LLC Address: PO BOX 251 , PACIFIC WA 998047 Phone: (253)863 -3881 Contractor License No: BOSSCSL981C2 Value of Construction: Type of Fire Protection: Type of Construction: doc: IBC -10/06 Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Inspection Request Line: 206 - 431 - 2451 Web site: http: / /wwwci.tukwila.wa.us $25,000.00 DEVELOPMENT PERMIT * *continued on next page ** Permit Number: D09 -262 Issue Date: 12/30/2009 Permit Expires On: 06/28/2010 Expiration Date: 02/22/2010 DESCRIPTION OF WORK: INSTALLATION OF (3) ANTENNAS, (3) M/W, AND (3) RRU'S IN A STEALTH ENCLOUSRE ON THE ROOF OF THE BUILDING. ONE RADIO CABINET TO BE INSTALLED INSIDE THE ENCLOSURE WITH THE ANTENNAS. Fees Collected: $893.19 International Building Code Edition: 2006 Occupancy per IBC: S2 D09 -262 Printed: 12 -30 -2009 Public Works Activities: Charmelization / Striping: N Curb Cut / Access / Sidewalk / CSS: N Fire Loop Hydrant: N Number: 0 Flood Control Zone: Hauling: N Start Time: Land Altering: Landscape Irrigation: Moving Oversize Load: Sanitary Side Sewer: Sewer Main Extension: Storm Drainage: Street Use: Water Main Extension: Water Meter: Permit Center Authorized Signature I hereby certify that I have read an governing this work will be complie The granting oft perms does not pre construction or perfgn�; e •f Signature: Print Name: doc: IBC -10/06 City oftukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Inspection Request Line: 206 - 431 -2451 Web site: http: / /www. ci.tukwila.wa.us N /0 eca Volumes: Cut 0 c.y. Private: Profit: N Private: Date: • Permit Number: Issue Date: Permit Expires On: Size (Inches): 0 End Time: Fill 0 c.y. Start Time: End Time: Public: Non - Profit: N Public: Date: 1 9 d b iDC) D09 -262 12/30/2009 06/28/2010 ned thi • ermit and know the same to be true and correct. All provisions of law and ordinances whether specified herein or not. e to give authority to violate or cancel the provisions of any other state or local laws regulating I am authorized to sign and obtain this development permit. This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. D09 -262 Printed: 12 -30 -2009 Parcel No.: 3523049074 Address: Suite No: Tenant: 1: ** *BUILDING DEPARTMENT CONDITIONS * ** 7: ** *FIRE DEPARTMENT CONDITIONS * ** doc: Cond -10/06 • a City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us 1231 ANDOVER PK W TUKW CASCADE CONTAINERS - CLEARWIRE PERMIT CONDITIONS Permit Number: Status: Applied Date: Issue Date: D09 -262 ISSUED 12/16/2009 12/30/2009 2: No changes shall be made to the approved plans unless approved by the design professional in responsible charge and the Building Official. 3: All permits, inspection records, and approved plans shall be at the job site and available to the inspectors prior to start of any construction. These documents shall be maintained and made available until final inspection approval is granted. 4: All construction shall be done in conformance with the approved plans and the requirements of the International Building Code or International Residential Code, International Mechanical Code, Washington State Energy Code. 5: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206- 431 - 3670). 6: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. 8: The attached set of building plans have been reviewed by the Fire Prevention Bureau and are acceptable with the following concerns: 9: Install a clearly labeled, readily visible and accessible EMERGENCY POWER OFF SWITCH. at the equipment. 10: The total number of fire extinguishers required for an ordinary hazard occupancy with Class A fire hazards is calculated at one extinguisher for each 1,500 sq. ft. of area. The extinguisher(s) should be of the "All Purpose" (2A, 20B:C) dry chemical type. Travel distance to any fire extinguisher must be 75' or less. (IFC 906.3) (NFPA 10, 3 -2.1) 11: Portable fire extinguishers, not housed in cabinets, shall be installed on the hangers or brackets supplied. Hangers or brackets shall be securely anchored to the mounting surface in accordance with the manufacturer's installation instructions. Portable fire extinguishers having a gross weight not exceeding 40 pounds (18 kg) shall be installed so that its top is not more than 5 feet (1524 mm) above the floor. Hand -held portable fire extinguishers having a gross weight exceeding 40 pounds (18 kg) shall be installed so that its top is not more than 3.5 feet (1067 mm) above the floor. The clearance between the floor and the bottom of the installed hand -held extinguishers shall not be less than 4 inches (102 mm). (IFC 906.7 and IFC 906.9) 12: Fire extinguishers shall not be obstructed or obscured from view. In rooms or areas in which visual obstruction cannot be completely avoided, means shall be provided to indicate the locations of the extinguishers. (IFC 906.6) 13: Extinguishers shall be located in conspicuous locations where they will be readily accessible and immediately available for use. These locations shall be along normal paths of travel, unless the fire code official determines that the hazard posed indicates the need for placement away from normal paths of travel. (1FC 906.5) D09 -262 Printed: 12 -30 -2009 14: Fire extinguishers require monthly and yearly inspections. They must have a tag or label securely attached that indicates the month and year that the inspection was performed and shall identify the company or person performing the service. Every six years stored pressure extinguishers shall be emptied and subjected to the applicable recharge procedures. If the required monthly and yearly inspections of the fire extinguisher(s) are not accomplished or the inspection tag is not completed, a reputable fire extinguisher service company will be required to conduct these required surveys. (NFPA 10, 4 -3, 4 -4) 15: Contact The Tukwila Fire Prevention Bureau to witness all required inspections and tests. (City Ordinances #2050 and #2051) 16: Any overlooked hazardous condition and/or violation of the adopted Fire or Building Codes does not imply approval of such condition or violation. 17: These plans were reviewed by Inspector 511. If you have any questions, please call Tukwila Fire Prevention Bureau at (206)575 -4407. 18: ** *PLANNING DIVISION COMMENTS * ** 19: Clearwire shall obtain a business license for this location prior to final approval. doc: Cond -10/06 • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us * * continued on next page ** • D09 -262 Printed: 12 -30 -2009 I hereby certify that I have read these conditions and will comply with them as outlined. All provisions of law and this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provision of any other work construction or the performance of work. Signature: Print Name: • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us (LM:14--N fle doc: Cond -10/06 D09 -262 Date: / c / / ordinances governing or local laws regulating Printed: 12 -30 -2009 CITY OF TUKWILA Community Development Department Public Works Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www.ci.lukwila.wa.us • • Building 'Permit No. Mechanical PermifNo. 4Plunibing/Gas Permit No. .4Public Works Permit No. Project - No. /(For office Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. * *Please Print ** �- 304i01 King Co Assessor's Tax No.: Site Address: 12-3 k p.wtoO" -' P.AR-1C W 1:44-wtic. t W A Suite Number: N/A Floor: NVA. Tenant Name: C(,tSC0.4 -. C o ✓t 4rA{ net/ a New Tenant: ❑ Yes ❑ ..No Property Owners Name: K Mace- I LLL Mailing Address: I Z3Z Avndooe r \�- ,-0C t,�1 - 11.A..w. le.. City W A State c9 Zip fCONTACT -:who do we contactwhen;your permitlissreadyto'beiissued Name: ' acv -v-t t Day Telephone: 7OG l i95 - -48W Mailing Address: `S1 Liz O 1ZZ "so Ave- r4E k,tr \du- 4...e.l W A 4$'033 City State Zip E -Mail Address^To -ke-t - Gevrt-41^. 'e. C,a%05.4 pr.. Conn Fax Number: '4ZS- (orl \ - (0Zo \ tG- ENERA'LCONTRACTOR QNffORMATION (ContractorrldfOrmatimilfor' Mechanical.(pg 4) GasPiping.(pg:5)) Company Name: T ) Mailing Address: City Contact Person: Day Telephone: E -Mail Address: Fax Number: Contractor Registration Number: Expiration Date: State Zip ARt 111TECT OF RECORD - All plans must be*etstamped.by Architect of Record ' •' F ' Company Name: Mailing Address: City Contact Person: Day Telephone: E -Mail Address: Fax Number: ENGINEER RECORD - All plans -must be wet stamped by:Engineer of Record Company Name: A` SA►1 Erui mar_ r tni Mailing Address: 525 uuevk 11"'` Contact Person: Ti vin Wdl,ck erg E% etn C 9' State Zip or- VIP/ State Day Telephone: SN /- 338 - qz/ Zip E -Mail Address:4wolete " CL 014' Sa r` e ip, rw. i CO'I I Fax Number: H:Applications \Forms - Applications On Line\2009 Applications \I -2009 - Permit Application.doc Revised 1 -2009 bh Page 1 of 6 ••••',.... • 4 '' `�"f . .0 : ° ', , :,m -f. U fa, 'Existing a a . ,••• ..,. • . , .q � , : k �• Interior Remodel X ,; - 7Addition to . .Existing: • g;, . ' ")Structure , '•� New . Wylie of . •. • Construction per - h - ' •IBC Typei f .: t Occu anc er P yP :IBC .'. ti 1S Floor /2 iEloor ... �......_. ,'` :,,,; 1 ,d :: ` 1 'Floors 'thru : -- - 'Basement ' t, Accessory .Structw t - :a?tc.r -0 :AttaCheirGarage ,DetachedKGarage • Attached Carport :. , Detached,Carport CoveredDeck . - 1.1ncovered:Dedk; ' i •" - '' ' • • 'BUILDING PERMIT INFORMATION - 206431 -3670 Valuation of Project (contractor's bid price): $ Z OUO Existing Building Valuation: $ Scope of Work (please provide detailed information): NS4- satl��.v.■ b f / '1 3A 1'Ii . i '.&5, 3 teq w.�� 3 WU's 1 1--t a S t∎ e c U lo s rt 0n1 4'L4 C car{ —ft.t • () JE /6 Co-lot/0a -Iv &. leis 11«( i41( eta E..) dos wc L1/4)1 Will there be new rack storage? ❑ Yes 171.. No If yes, a separate permit and plan submittal will be required. 4EroviderAlllBuildingFAreasiin • 'Square Footage Below PLANNING DIVISION: Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) *For an Accessory dwelling, provide the following: Lot Area (sq ft): Floor area of principal dwelling: Floor area of accessory dwelling: *Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard: Compact: Handicap: Will there be a change in use? ❑ Yes ❑ No If `yes ", explain: FIRE PROTECTION/HAZARDOUS MATERIALS: ❑ Sprinklers ❑ Automatic Fire Alarm ❑ None ❑ Other (specify) Will there be storage or use of flammable, combustible or hazardous materials in the building? ❑ Yes ❑ No If 'yes', attach list of materials and storage locations on a separate 8 -1/2 "x I1 " paper including quantities and Material Safety Data Sheets. SEPTIC SYSTEM ❑ On -site Septic System — For on -site septic system, provide 2 copies of a current septic design approved by King County Health Department. H :ApplicationsTonns- Applications On Line\2009 Applications \1-2009 - Pemut Applicnhion.doc Revised: 1 -2009 bh Page 2 of 6 Date Application Accepted: 21 j j D) D Date Application Expires: 541rai Y Y � � S Staff Initials PERMIT APPLICATION NOTES — Applicable to all permits in this application Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. Building and Mechanical Permit The Building Official may grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). Plumbing Permit The Building Official may grant one extension of time for an additional period not exceeding 180 days. The extension shall be requested in writing and justifiable cause demonstrated. Section 103.4.3 Uniform Plumbing Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER R AITHORIZED A ENT: Signature: [ _ k I - Print Name: 1 Oda Gex r t Sh Mailing Address: g1 1L lZZ1.31J AVE N E H:\Applications\Fonns- Applications On Line\2009 Applications \I -2009 - Permit Application.doc Revised. 1 -2009 bh Date: la 27 / Day Telephone: 20(o - Qa- 4:8q I rklawo W w 98013 City State Zip Page 6 of 6 Parcel No.: 3523049074 Permit Number: D09 -262 Address: 1231 ANDOVER PK W TUKW Status: PENDING ' Suite No: Applied Date: 12/16/2009 Applicant: CASCADE CONTAINERS - CLEARWIRE Issue Date: Receipt No.: R09 - 02005 Initials: User ID: JEM 1165 Payee: CLEARWIRE LEGACY LLC TRANSACTION LIST: Type Method Descriptio Amount Payment Check 00151364 893.19 Authorization No. ACCOUNT ITEM LIST: Description BUILDING - NONRES PLAN CHECK - NONRES STATE BUILDING SURCHARGE • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us RECEIPT • Payment Amount: $893.19 Account Code Current Pmts 000.322.100 000.345.830 640.237.114 Total: $893.19 Payment Date: 12/16/2009 10:41 AM Balance: $0.00 538.60 350.09 4.50 PAYMENT RECEIVED doc: Receiot -06 Printed: 12 -16 -2009 P ect: Se �( Type of Inspection: Address: -t23\ -Aaskai tA i Date Called: Special Instructions: Date Wanted: 3 , i '- t v p.m. Requester: Phone No: INSPECTION RECORD Retain a copy with permit INS CTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION t 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -36 Approved per applicable codes. D Corrections required prior to approval. [COMMENTS: l pi - k Ci.e." lr A t l A cttorr:: 1 $60.00 REINSPECTIO FEE REQUIRE . Prior to inspection, fee must be paid at 6300 Southcente Blvd., Suite 100. Call to schedule reinspection. Receipt No.: Da: �c_2 — tom Date: Project: I Type of Inspection: \ Address: I' Z 3 + 4Abou r I n/ Date Called: ._--- Special Instructions: G l a /' � • ' P Date Wanted: -� ` / �' �, -- I p.m. Requester: Phone No: Z ( <4 2. INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION f - 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -36 Approved per applicable codes. El Corrections required prior to approval. f. COMMENTS: Inspecto $61.00 J EINSPECTION FEE REQUIR pail a 6300 Southcenter Blvd., Suite Receip$.IVo.: 04 '&j W - 1 "JO k % w ( ---�1 Date: Prio to inspection, fee must be 00. Call to schedule reinspection. 'Date: Do g- 2 Project: � C � Ae2 -5 Type of Inspe f t /t7 Address: Date Called: Special Instructions: ` C ( et I 0 .A-e, Date Wanted: ` (� _ / v 6.7 p.m. Requester: Phone yo - e -5423 PERMIT NO. CITY OF TUKWILA BUILDING DIVISION INSPECTION NO. INSPECTION RECORD Retain a copy with permit 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 Approved per applicable codes. Corrections required prior to approval. COMMENTS: ,.o C,Yri4'3 Inspector: Date 3 11 El $60.00 REINSPECTION #EE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: 'Date: Prrojnnectt:�� A ,� l al #J L- 6A�OA. A. PUS pection: Type of =ion / on AA , ell Address : 1231 Anoev� t,JeJ Date Called: Special Instructions: C leb T t,/J ' l ` f , I-Afit1 Date Wanted: -, C m Requester: tllJ1��P11 n A (,,,A ` , A. e.,4 Phone eN No: � 7 ? � C ky75:v INSPECTION RECORD 0 I tain a copy with permit (� INSPECZ NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 COMMENTS: Inspe Date: z - z5 - lb Approved per applicable codes. ❑ Corrections required prior to approval. fl $604 REINSPECTION EE REQUIRED. Prior to inspection, fee must be paid t 6300 Southcenter Blvd., Sulte 100. Call to schedule reinspection. Receipt No.: Date: Project: . f19.rMAa� nCA/r 4 i,ve4.$ -i A#'w, Type of Inspection: z' ,fair - /OA.,57 0. Address: , 42.'? 4 nlJO.Q ,J/L Gc Called: Special Instructions: Date Wanted: ■ — i7 —‘/ P Requester: /1/ .177 Phone 5 2 ` S4/2 y�5 � 3 069 -2 !o2 INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION ( rte 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -360 CO ENTS: 4 spector: / Date - / 7 — /0 REINSPECTION E REQUIRED. Prior to inspection, fee must be t 6300 Southcenter c lvd., Suite 100. Call to schedule reinspection. Re No.: IDate: Approved per applicable codes. ❑ Corrections required prior to approval. Project: Sprinklers: T of Inspection Address: t .. 3 a... Suite #: f -P 0 Contact Person: (). ` 01-iw Special Instructions: Occupancy Type: Phone N o`: Needs Shift Inspection: Sprinklers: Fire Alarm: Hood & Duct: Monitor: Pre -Fire: Permits: Occupancy Type: INSPECTION NUMBER Andover Park East Tukwila Wa 981 206 -575 -4407 Et-Approved per applicable codes. COMMENTS: C f $80.00 REINSPECTION FEE REQUIRED. You will receive an invoice from the City of Tukwila Finance Department. Call to schedule a reinspection. Word /Inspection Record Form.Doc INSPECTION RECORD Retain a copy with permit CITY OF TUKWILA FIRE DEPARTMENT 1/13/06 PERMIT NUMBERS Corrections required prior to approval. T.F.D. Form F.P. 113 i ARTISAN ENGINEERING, LLC 325 West 13 Avenue Eugene, Oregon 97401 -3402 Phone: 541- 338 -9488 Fax: 541- 338 -9483 www.artisanengineering.com November 23, 2009 Mr. Kevin Michael Cascadia PM, LLC 3322 South Bay Road Olympia, WA 98506 Re: Dear Kevin: Sinperely, Design Stealth Shroud and Check Existing Fa) aliggyisvpruse Building at 1232 Andover Park West in Tukwila, WA for the Clearwire Cabinef and Antenna Installation (WA TAC0420 Kent Business) We appreciate your recent request to assist you with the Construction Drawings for the installation of Clearwire antennas in a roof - mounted stealth shrouded structure at 1232 Andover Park West in Tukwila, Washington. We also designed the support beams for the radio equipment cabinet inside the base of the roof mounted assembly. The design is based on the zoning drawings and equipment plan that you emailed to us last month and on the information gathered during the site visit in September. The existing structure is a large concrete walled warehouse building with a panelized wood framed roof. The attached design is for a 10 -foot wide by 14 -foot tall shroud on faux chimney that is constructed with FRP material that is transparent to the antennas mounted inside of it. This chimney structure is anchored to the roof with 6x sleeper through bolted and connected to strong back beams under the existing roof panels. These new beams will carry the corner posts of the stealth shroud to the existing 4x roof beams and underlying 8- inch glulam girder. The new shroud will be placed above a concrete wall which was the original concrete end wall. The radio cabinet will be mounted on a pair of 6x beams spanning between the roof mounted sleeper beams. We have designed the anchorage of the stealth chimney to the roof using a wind speed of 120 mph (3 second gusting) at Exposure C. This wind load determined the size and spacing of the steel thru -bolts into the roof framing. We have also designed the anchorage of the cabinet to the beams using the appropriate site specific factor for seismic forces . based on the current Washington State Building Code (IBC 2006, 2 Amendment) as adopted by the State of Washington. Please refer to the attached calculations and to the submitted construction drawings. We have not designed the FRP members or panels as this is a proprietary component designed by others. We appreciate the opportunity to assist yo f • . the project. If you have any additional questions, comments, or concerns plea Timothy Wolden, PE Principal, Artisan Engineering, LLC Jk REVIEWED FOR CODE COMPLIANCE APPROVED DEC 2 4 2009 City of Tukwila RECEIVED_ CITY OF TU LA DEC 16 2009 PERMIT CENTER ARTISAN ENGINEERING, LLC 325 W. 13th Avenue Eugene, Oregon 97401 -3402 Tel (541) 338 -9488 • Fax (541) 338 -9483 www.artisanengineering.com Job No.: (pct: 55 Page : J of: 3 By: / Date: �� ^i �l i q C 4-2-0 Project: S4-.e v•-1 , JF�rvcm, \a' 4 s cv5vAcL stalk, t 1h-w g/-e-v•- (ti,) Loy15 s v\;, 5(pa- ) / 1/ 1 S 6 x = 3 4/Cl x 5 IBS 3L �- S(9-70!f- (9 > 20D• Specific Gravity Lag Screw Unthreaded Shank Diameter, D G 1/4" 5/16" 3/8" 7/16" 1/2" 5/8" 3/4" 7/8" 1" 1 -1/8" 1 -1/4 0.73 e.1 0"1 ..� :! r:.#` -s r - 0.68 i' - '°f d - _p Dy6 li 397 $ ii }.�j > 3t 357 7• ' W 1 9u : 469 ,„�9' ~450 £ trS� 1 j'-ki C -_.7� 422 '� 7'1' <- P f .1`3 <. 538 f5'16':> � .> , 484 ,•f l t47ai 604 ,4 579 �` tt' 543 5319'.� 1 . x r -'j1690,...',.: 668 :,.....640 600 ,� '587= 789 ',';;`,7:5.7,=:.4z. 709 j . 905 88 5 _ ` :, -. .�. .r ' 813 �`.5 .; 2796. 1016 i ",974 * f `f •a7�3 913 i� 893. tp 1123 ,,,�` -�' ��Q��aY..t� -,1,�f 1009 9:. ? 9$:fi,., 1226 . 141,6A ,i ii$ ^ ., �... ..t- 1103 t" + t t0i7tg� 132' �; T °l: R 119: rod' 6 0.58 ` % I �- '`t``'` . 0 5 5 5..QQl� b..11.tF',t .9 ) , ... -- 0 5 1 ,,,�.5��2-• ,,::: Olb01k 8cj,�iK�ss��'•g, ai�t,.,..a,..(L��t 281 . 0 / 260 r iJ ) 232 7 -.Z5r, � .t. -�. 4� 332 h V`t 3,0,7' 4. . �Li. i � � 274 , 6n.•n. ,6$ 381 1 r+ )x � 3'14 M£ , 0 , y.•Gt' 428 395 351 ` 342 P 4 . .z,,.i. .. ,t 473 f �,CJ . 1 390 .�� -. ` , : -.. 559 1 516•' a 461 4471 .W, �..0 641 d .: 592 528 ; s °$1:3;. ° .... 719 It'664.',; d ,:. 593 Cc �5.7.6,�';:r' 795 1 -"' � 1,134'. t ..b 656 63..t� 869 ? 802b1' ) l � 716 695 941 ! 1 yM1 '8 77. ' i ,,. 0.49 �. •.e 2 9 , of ' ;;.;,0 4'1��? . 0.46 n r; ,0,44P.A 218 t .c ,' 2 45 � 199 ,)`86'S 258 z, ��''���� ,: „ 235 3 220 296 r s F «27,$ti 4 t�•t ROM 269 ° '''.1Z.:-ix,,, t 332 5 � 9 -� t�9�3,; . a 302 X283 " ;' 367 434 ` �4 8•s,'' . a.. R t 4. 395 F369 . ` 498 ° ., � ,. �� ° .. �: V •/. . . ! 453 423 '. s p 559 � 6 5 ` ..y �� 508 .,,•4 .x` 617 I � ..�..:� 562 ` g525g4'i 674 634.,., 613 ` , 55 731 68� 66• 1f62 5. '� < r �� �9 334 w>, 3120 .,i 0.43 �:� + t � 0.41 0240V 179 ,>a, t��a173_'�� 167 , . 161` 212 �2USt�.... 198 19 0, , 243 . f _ , r235� I 226 ; 218< 273 , , ,,. . �� 254 2451 ., 302 Lr;- �. 281 hiP71 357 <f. 3. ` �= �..... 332 .i320 409 r' "3 .95 r , ,.. 381 „ 459 '0, � 428 . 412:. 508 ° '"4 1 ��� .�0.��- 473 't4551f 554 yS3$ t . 35J.; � 516 e;';44941;'5.i; 60 t X37, 55 ;t`5'3 0.39 :k.t; . , ,cm.. ,:: "r 0.37 ; .ti 0 6 ;;;, 0.35 ♦ ti ;w4 \i' . s0 - 155 ;.'. 449 143 •r . 7 132 a g v'.�� 1:109 IM10 183 1 ;;,1'76 169 �.' . ;,,. 156 � ):� 210 vv!-,-,x,227.:._,: 194 6:06., , � 179 L P i 7 i .,2149i 236 218 :209 :..:: 200 r r d•i 1.67. . 261 ;45'1§ _ 241 ; 222 11$5: - : .. 308 ' r. 296`' 285 f 111::: , 262 9 118 ,4 353 . '340 ; , : 326 .. 5 . 300 � T ,P "• 2`50: 397 38t., 367 ,; 352 337 �d 1,2.8: �' { 438 : ' ,42 a 405 389 # 373 -k r ;11 xT 479 :4611:11.949 443 '4256 � „iA 407 . �..qt., ,t � e 09 51 47 44 : 44 'E • . 0 • „ •_ 11.2 Withdrawal Design Values 11.2.1 Lag Screws 11.2.1.1 The withdrawal design values, in lbs. /in. of penetration, for a single lag screw inserted in side grain, with the lag screw axis perpendicular to the wood fibers, shall be determined from Table 11.2A or Equation 11.2 -1, within the range of specific gravities and screw diameters given in Table 11.2A. Tabulated nominal design values, W, shall be multiplied by all applicable adjustment factors (see Table 10.3.1) to obtain allowable design values, W'. W= 1800G (11.2 -1) Table 11.2A Lag Screw Withdrawal Design Values (W) Tabulated withdrawal design values (W) are in pounds per inch of thread penetration into side grain of main mem Length of thread penetration in main member shall not include the length of the tapered tip (see Appendix I 1. Tabulated withdrawal design values (W) for lag screw connections s \ A 424 _ n 11 be multiplied by all applicable adjustment factors (see T a bl e 10.3 AMERICAN WOOD COUNCIL 2 �3 11.2.1.2 When lag screws are loaded in withdr from end grain, nominal withdrawal design value shall be multiplied by the end grain factor, C = 0.7 11.2.1.3 When lag screws are loaded in withdrl the allowable tensile strength of the lag screw at tht (root) section shall not be exceeded (see 10.2.3). ARTISAN ENGINEERING, LI C 325 W. 13th Avenue Eugene, Oregon 97401 -3402 Tel (541) 338 -9488 • Fax (541) 338 -9483 www.artisanengineering.com JobNo.: (o 5" `6 By: Page : of: 3 Date: ` / I Project: 6 9J_L cfi.A01 ?Q 4 - ( Sid to (ri) . (dqo -<)cQ eck A, • 11- 5 Vv , _3 C_46L. .aes-kC *x. t() Vv-ks- .- V-toc 1).r I\4 1-'- B ,021.-•ms") -., , - . 37 1 r)t, P Z 2w 0 QosA , (iA C In- D 19 • ) 2,9 V-�� 4 2�) Z 55, G A — C _ 6 1 - C L J C z bvvy -4"v s z 'SO yvt'' LLfbz_ e . - f3EAM 4 PURL /6,1 5 .HeoULE MARK SIZE r'Pt caroBE,¢ . In "tc,tou vo o 4 ).3a05 , 21 ct) OZ. C O c a g°3 C1.)1 x'L443' 9 " V/9 v 2 9 "x24'4," 4L. LAM_ • 4L.GLAM. 44. 4.4/4. , 11.., 3 6 G CrhT• o . 'k " • T IN. 219 "! 31' +" 9°x24 V6' Gt. LAM. • 1"+5S" • /e " !' 9 "x 24 xv 4t. LA M. I • - 8 • 9" 9 "1/24 4 4[.64M.o v.' 4 " . S" 9"x2' 4.44M, „ a' - 1 9"x I,,'/4 0-CAM. . Oi74” t 7/6 9 "x21 fig" 4t, (.4 M. ', ` "4 "a C6n n" q "X 27 C'g' 4G. GA M. 0 2." - 4 x 1 v twee ,goo{ hl .n f IO TE se I.wa 9. f o • NJTE: CAMBLR CANTI -ILV6R GNDf CV B5 'S. C' T(10 C 1 /a " ABOVE 1 TA J4sNT LINO AT Sup Fo RT PQo- DUCE Ls lb"? N' C.A././071,:t_ '"F•1 coven A BovE• I 1 CNT V,PJO1 • • p'e NORTH JMT--,i • ul 10'•�3" _,... P -/ P./ P -/ P -/ P -/ - -/ -/ P -I W V 4 V `o' 0 P -/ d P- P./ P -/ - I P -/ P -I P -/ `0 (k) Ia nll� 0 • JC tif fi Lc) efr CAI r Too of eooF 1 :∎; { R dr• $0.5E' e Ul SSl1S S41. -1) P -I P -I P -/ P -/ -/ TgP o P 156 kV, P -/ j✓ �ti P -/ P -/ P -I 41 P�l 1 U P -/ P - I P-/ P -/ f I p -I P -, P -I . P--, ACTIVITY NUMBER: D09 -262 DATE: 12 -16 -09 PROJECT NAME: CASCADE CONTAINERS - CLEARWIRE SITE ADDRESS: 1231 ANDOVER PK W X Original Plan Submittal Response to Correction Letter # Response to Incomplete Letter # Revision # after Permit Issued DEPARTMENTS: -61 d 4 Building Division J ,Ns N /A- 1- .' Public Work DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete Comments: REVIEWER'S INITIALS: APERMITCOORD Y f PLAN REVIEW /ROUTING SLIP APPROVALS OR CORRECTIONS: Approved ❑ Approved with Conditions Notation: REVIEWER'S INITIALS: Documents/routing slip.doc 2 -28 -02 Fire Prevention um— Structural n Incomplete n DATE: Planning Division Permit Coordinator DUE DATE: 12-17-09 Not Applicable TUES/THURS ROUTING: Please Route Structural Review Required ❑ No further Review Required n DATE: Not Approved (attach comments) ❑ C Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: DUE DATE: 01-14-10 Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: Bond Bond Company Name Bond Account Number Effective Date Expiration Date Cancel Date Impaired Date Bond Amount Received Date 1 DEVELOPERS SURETY a INDEM CO 857070C 02/20/2002 Until Cancelled 4/11/2002 ARCHIVED $12,000.00 02/22/2002 License Name Type Specialty 1 Specialty 2 Effective Date Expiration Date Status BOSSCS *006JK BOSS CONSTRUCTION SERVICES CONSTRUCTION CONTRACTOR GENERAL UNUSED 4/12/2000 4/11/2002 ARCHIVED Name Role Effective Date Expiration Date BRENDEN, MICHAEL T PARTNER /MEMBER 02/22/2002 Amount Insurance Company Name Policy Number Effective Date Expiration Date Cancel Date Impaired Date Amount Received Date Untitled Page 6 • General /Specialty Contractor A business registered as a construction contractor with LEtI to perform construction work within the scope of its specialty. A General or Specialty construction Contractor must maintain a surety bond or assignment of account and carry general liability insurance. Business and Licensing Information Name Phone Address Suite /Apt. City State Zip County Business Type Parent Company BOSS CONSTRUCTION SERVICES LLC 2538633881 PO BOX 251 PACIFIC WA 98047 KING Limited Liability Company UBI No. Status License No. License Type Effective Date Expiration Date Suspend Date Specialty 1 Specialty 2 602178221 ACTIVE BOSSCSL981C2 CONSTRUCTION CONTRACTOR 2/22/2002 2/22/2010 GENERAL UNUSED Other Associated Licenses Business Owner Information Bond Information Insurance Information https://fortress.wa.gov/lni/bbip/Detail.aspx Page 1 of 2 12/30/2009 REVIEWED FOR CODE COMPLIANCE APPROVED DEC 2 4 2G�i City() ; SUBMITTAL D� �- PROJECT CONTACTS WA- TAC0420 KENT BUSINESS CONSTRUCTION DRAWINGS SUBMITTAL / REVISIONS NO. DATE INIT DESCRIPTION 01 8 -30-09 JP ZD SUBMITTAL SITE ADDRESS 1232 ANDOVER PARK W. TUKWILLA, WA 98188 APN: 3523049074 SITE ADDRESS: LATITUDE LONGITUDE' JURISDICTION APN GROUND ELEVATION STRUCTURE HEIGHT OCCUPANCY GROUP CONSTRUCTION TYPE - ZONING 1232 ANDOVER PARK W TUKWILA, WA 98188 47" 26' 30.89" N 122 15' 13.44" W TUKWILA, WA 3523049074 20' AMSL 44' AGL B V-B C - COMMERCIAL PROJECT DATA AR GOVERNING CODES IBC -2003, INTERNATIONAL BUILDING CODE W/ LOCAL AMENDMENTS NEC -2005, NATIONAL ELECTRICAL CODE INS IALLA[ION IS UNMANNED AND NOT FOR HUMAN HABITATION. T REQUIR PER ADA REVISIONS No chances shall be made to the scope of work without prior approval of Tukwila Building Division. NOTE: Revisions will require a new plan submittal I ai plan review fees. ,,.,i... Ic w��i{�p t j authorize APPLICANT CLEARWIRE US LLC 4.400 CARILLON POINT KIRKLAND, WA 98033 PROPERTY OWNER COMMENCEMENT TERRACE ASSOCIATION LLC 29 ST. HELENS AVENUE TACOMA, WA 98402 PH: 206.282.1103 CONSULTING ENGINEER ARTISAN ENGINEERING 11M WOLDEN PE 325 WEST 13TH AVE. EUGENE, OR 97401 PH: 541.338.9488 SITE AQUISMON CONSULTANT CASCADIA PM 8760 122ND AVENUE, NE KIRKLAND, WA 98033 NICKI KERSWILL PH: 425.443.1055 ZONING CONSULTANT CASCADIA PM 5501 NE 109TH COURT, SUITE A -2 VANCOUVER, WA 98662 NOAH GROZDIN PH: 971.285.6645 CONSTRUCTION MANAGEMENT CASCADIA PM 8760 122ND AVENUE, NE KIRKLAND, WA 98033 TODD GERRISH PH: 206.498.6891 SEPARATE PERM REQUIRED FO . PROJECT SUMMARY Mechanical Elecbicai Plumbing Gas Piping City of Tukwila BUILDING DIVISIO THIS PROJECT INCLUDES THE FOLLOWING SCOPE OF WORK 1. PROPOSED CONSTRUCTION OF A WMMAX TELECOMMUNICATIONS FACILITY ON THE ROOFTOP OF AN EXISTING SINGLE STORY WAREHOUSE BUILDING. 2. PROPOSED INSTALLATION OF RF TRANSMISSION EQUIPMENT AND ANTENNAS WITHIN A 10'X10'X14' CONCEALMENT STRUCTURE ON TOP OF THE EXISTING BUILDING. 3. PROPOSED INSTALLATION OF CLEARWIRE RF EQUIPMENT IN A 25 "X25'X54" CABINET MOUNTED ON SLEEPERS CONNECTED TO THE ROOFTOP OF THE EXISTING BUILDING. 4. PROPOSED INSTALLATION OF (3) PANEL, (3) MICROWAVE, (3) RRU'S & (1) GPS CLEARWIRE ANTENNA/S TO BE MOUNTED WITHIN THE WALLS OF THE CONCEALMENT STRUCTURE. 5. PROPOSED INSTALLATION OF A NEW 100A ELECTRICAL SERVICE. SHEET DRAWING INDEX DESCRIPTION T -1 TRLE SHEET A -1 SITE PLAN A -2 ENLARGED SITE PLAN A -3 ELEVATIONS A -3.1 ELEVATIONS A-4 EQUIPMENT DETAILS A-4.1 EQUIPMENT PLATFORM DETAIL A -5 ANTENNA DETAILS A-6 STEALTH STRUCTURAL PLAN '' -7 ROOF PLAN -1 ELECTRICAL SITE PLAN -2 ELECTRICAL POWER RISER DIAGRAM -3 ELECTRICAL DETAILS N-1 GENERAL NOTES N-2 GENERAL NOTES -N-3 GENERAL NOTES N-4 GENERAL NOTES WA- TAC0420 CELL SITE RECEIVED CITY OF TUKWILA DEC 16 2009 PERMIT CENTER poov 21v2 DRIVING DIRECTIONS HEAD 1 -5 N TOWARD SEATTLE TAKE EXIT 153 FOR SOUTHCENTER PARKWAY AND MALL 0.1 MI KEEP RIGHT AT THE FORK, FOLLOW SIGNS FOR TUKWILLA/SOUTHCENTER PKWY S AND MERGE ONTO SOUTHCENTER PKWY 1.2 MI TURN LEFT AT S 180TH ST 0.3 MI TURN LEFT AT ANDOVER PARK W DESTINATION WILL BE ON THE RIGHT 4.46 FT 1232 ANDOVER PARK W, TUKWILA, KING, WASHINGTON 98188 SITE PLAN TAX PARCEL# 3523049092 TAX PARCEL# 3523049103 TAX PARCEL# 3523049120 . \ TAX PARCEL# 3523049119 (E) WAREHOUSE / DISTRIBUTION BUILDING TAX PARCEL# 3523049085 (E) BLDG. SECTION X LINES OF (E) BLDG. ADDITION a (E) BLDG. SECTION _ LINES FROM AS -BUILT DRAWINGS S 180TH ST TAX PARCEL# 3523049055 330' ± — -cJ PROJECT AREA SCALE: 1" = 60' (11X17) SCALE: 1" = 30' (22X34) TAX PARCEL# 3523049072 TAX PARCEL# . 3523049095 TAX PARCEL# 352304HYDR CO DE C E O w Ag Ep E APPl00VFD DEC 2 4 1009 B City of Tukwila RECEIV CITY OF KWILA /C J PERMIT CENTER 30' NOTE SITE PLAN NOT FROM SURVEY. 60' 120' clea rw're Cascadia \PM 8760 122ND AVE, NE KIRKLAND, WA 98033 PH: (425) 828 -1008 PROJECT NO.: DRAWN BY: CHECKED BY: 2313 KKN JP SITE NO. WA- TAC0420 SITE NAME KENT BUSINESS SITE ADDRESS 1232 ANDOVER PARK W TUKWILLA, WA 98188 APN: 3523049074 SHEET TITLE SITE PLAN SHEET NO. A -1 SUBMITTAL I REVISIONS NO. DATE INIT DESCRIPTION 01 8 -30-09 JP ZD SUBMITTAL SITE PLAN TAX PARCEL# 3523049092 TAX PARCEL# 3523049103 TAX PARCEL# 3523049120 . \ TAX PARCEL# 3523049119 (E) WAREHOUSE / DISTRIBUTION BUILDING TAX PARCEL# 3523049085 (E) BLDG. SECTION X LINES OF (E) BLDG. ADDITION a (E) BLDG. SECTION _ LINES FROM AS -BUILT DRAWINGS S 180TH ST TAX PARCEL# 3523049055 330' ± — -cJ PROJECT AREA SCALE: 1" = 60' (11X17) SCALE: 1" = 30' (22X34) TAX PARCEL# 3523049072 TAX PARCEL# . 3523049095 TAX PARCEL# 352304HYDR CO DE C E O w Ag Ep E APPl00VFD DEC 2 4 1009 B City of Tukwila RECEIV CITY OF KWILA /C J PERMIT CENTER 30' NOTE SITE PLAN NOT FROM SURVEY. 60' 120' clea rw're Cascadia \PM 8760 122ND AVE, NE KIRKLAND, WA 98033 PH: (425) 828 -1008 PROJECT NO.: DRAWN BY: CHECKED BY: 2313 KKN JP SITE NO. WA- TAC0420 SITE NAME KENT BUSINESS SITE ADDRESS 1232 ANDOVER PARK W TUKWILLA, WA 98188 APN: 3523049074 SHEET TITLE SITE PLAN SHEET NO. A -1 ► 1R) 4X6 SLEEPERS r (E) ROOF DECK - 1 ASPHALT ROOF 1 I ENLARGED SITE PLAN ► ► (N) CLEARWIRE RF ANTENNA, ► MW & RRU MOUNTED TO CONCEALMENT STRUCTURE - SECTOR 0' - RED ► RE: A-5, A-6 I (N) RF TRANSPARENT ANTENNA ► CONCEALMENT STRUCTURE RE: A-6 & A -7 (N) 25"X25"X 54" RF EQUIPMENT CABINET MOUNTED TO 4"x6" SLEEPERS W/ OPTIONAL PLINTH RE: A-4 (N) CLEARWIRE RF ANTENNA, MW & RRU MOUNTED TO CONCEALMENT STRUCTURE - SECTOR 240' - YELLOW RE: A -5, A-6 CAUTION: DUE TO THE AGE OF THE BUILDING THERE IS POTENTIAL FOR THE PRESENCE OF LEAD BASED PAINT & ASBESTOS CONTAMINATED MATERIALS. CONTRACTOR TO VERIFY ANTENNA RAD CENTERS & SECTORS WITH RF ENGINEER PRIOR TO INSTALLATION. 00 4.. CABINET RE: E-3 2-3/813 SCH. 40 ANT. MOUNT PIPE W 1-3/8" UNITSTRUT SUPPORT CHANNEL @ TOP & MIDDLE, TYP. ► ► ► ► r (E) ROOF DECK - ASPHALT ROOF (N) 2-3" CONDUITS FOR FIBER AND COAX FROM TELCO BOX ON EQUIPMENT CABINET TO RRU'S AND MWS - MOUNT ON SLEEPERS ACROSS ROOF DECK & UP FRP STRUCTURE. FIELD ROUTE PER BEST PRACTICE. ROUTE TO POWER SOURCE FIELD MOUNT DISCONNECT TO FRP STRUCTURE (N) CLEARWIRE RF ANTENNA, MW & RRU MOUNTED TO CONCEALMENT STRUCTURE - SECTOR 120' -BLUE RE: A -5, A-0 FRP 4X4 VERT. & BASE PLATE RE: A-6, A -7 I SCALE: 1/2" = 1'-0" (11X17) 0' SCALE: 1" = 1'-0" (22X34) ► 3'X4' ACCESS DOOR (E) BLDG. SECTION LINE "L" r (E) ROOF DECK - ASPHALT ROOF RECEIVED CITY OF TUKWILA DEC 16 2009 PERMIT CENTER CODE REVIEWED FOR APPROVED DEC COVED DE C 2 4 209 Ci ty of Tukwila BUILDING DIVISInr`' 1 W E NOTE SITE PLAN NOT FROM SURVEY. clearw're Cascadia\ PM 8760 122ND AVE, NE KIRKLAND, WA 98033 PH: (425) 828 -1008 PROJECT NO.: DRAWN BY: CHECKED BY: EXPIRES 6/9/ 2313 KKN JP SITE NO. WA -TAC 0420 SITE NAME KENT BUSINESS SITE ADDRESS 1232 ANDOVER PARK W. TUKWILLA, WA 98188 APN: 3523049074 SHEET TITLE ENLARGED SITE PLAN SHEET NO. A -2 SUBMITTAL / REVISIONS O. DATE INIT DESCRIPTION 0 1 8-30-09 JP ZD SUBMITTAL ► 1R) 4X6 SLEEPERS r (E) ROOF DECK - 1 ASPHALT ROOF 1 I ENLARGED SITE PLAN ► ► (N) CLEARWIRE RF ANTENNA, ► MW & RRU MOUNTED TO CONCEALMENT STRUCTURE - SECTOR 0' - RED ► RE: A-5, A-6 I (N) RF TRANSPARENT ANTENNA ► CONCEALMENT STRUCTURE RE: A-6 & A -7 (N) 25"X25"X 54" RF EQUIPMENT CABINET MOUNTED TO 4"x6" SLEEPERS W/ OPTIONAL PLINTH RE: A-4 (N) CLEARWIRE RF ANTENNA, MW & RRU MOUNTED TO CONCEALMENT STRUCTURE - SECTOR 240' - YELLOW RE: A -5, A-6 CAUTION: DUE TO THE AGE OF THE BUILDING THERE IS POTENTIAL FOR THE PRESENCE OF LEAD BASED PAINT & ASBESTOS CONTAMINATED MATERIALS. CONTRACTOR TO VERIFY ANTENNA RAD CENTERS & SECTORS WITH RF ENGINEER PRIOR TO INSTALLATION. 00 4.. CABINET RE: E-3 2-3/813 SCH. 40 ANT. MOUNT PIPE W 1-3/8" UNITSTRUT SUPPORT CHANNEL @ TOP & MIDDLE, TYP. ► ► ► ► r (E) ROOF DECK - ASPHALT ROOF (N) 2-3" CONDUITS FOR FIBER AND COAX FROM TELCO BOX ON EQUIPMENT CABINET TO RRU'S AND MWS - MOUNT ON SLEEPERS ACROSS ROOF DECK & UP FRP STRUCTURE. FIELD ROUTE PER BEST PRACTICE. ROUTE TO POWER SOURCE FIELD MOUNT DISCONNECT TO FRP STRUCTURE (N) CLEARWIRE RF ANTENNA, MW & RRU MOUNTED TO CONCEALMENT STRUCTURE - SECTOR 120' -BLUE RE: A -5, A-0 FRP 4X4 VERT. & BASE PLATE RE: A-6, A -7 I SCALE: 1/2" = 1'-0" (11X17) 0' SCALE: 1" = 1'-0" (22X34) ► 3'X4' ACCESS DOOR (E) BLDG. SECTION LINE "L" r (E) ROOF DECK - ASPHALT ROOF RECEIVED CITY OF TUKWILA DEC 16 2009 PERMIT CENTER CODE REVIEWED FOR APPROVED DEC COVED DE C 2 4 209 Ci ty of Tukwila BUILDING DIVISInr`' 1 W E NOTE SITE PLAN NOT FROM SURVEY. clearw're Cascadia\ PM 8760 122ND AVE, NE KIRKLAND, WA 98033 PH: (425) 828 -1008 PROJECT NO.: DRAWN BY: CHECKED BY: EXPIRES 6/9/ 2313 KKN JP SITE NO. WA -TAC 0420 SITE NAME KENT BUSINESS SITE ADDRESS 1232 ANDOVER PARK W. TUKWILLA, WA 98188 APN: 3523049074 SHEET TITLE ENLARGED SITE PLAN SHEET NO. A -2 SCALE: 1" = 20'-0" (11X17) SCALE: 1" = 10' (22X34) (N) CLEARWIRE ANTENNAS 43'-0" AGL (N) CLEARWIRE MICROWAVES 41'-0" AGL (E) ACCESS LADDER NORTH ELEVATION EAST ELEVATION 10 (N) 10 'X 10' X 14'-0", RF TRANSPARENT, CONCEALMENT STRUCTURE FOR CLEARWIRE TELECOMMUNICATIONS EQUIPMENT - FINNISH TO MATCH EXISTING BUILDING RE A-0 (N) ANTENNA, MW & RRU MOUNTED TO HORIZ. ANTENNA MOUNTING PIPES LOCATED AT TOP AND MIDDLE OF FRP STRUCTURE: A -5, A-0 (N) CLEARWIRE RF EQUIPMENT CABINET MOUNTED TO 2X6 SLEEPERS CONNECTED TO ROOF DECK RE: A -4, A -7 (N) CLEARWIRE ANTENNAS 43' -0" AGL (N) CLEARWIRE MICROWAVES 41'-0" AGL (E) WAREHOUSE / DISTRIBUTION BUILDING REVIEWED FOR CODE COMPLIANCE APPROVED DEC 2 4 2009 City of Tukwila i'WDING DIVISION 10'-0" (TYP) U (N) ACCESS DOOR RE: A-S (N) 10 'X 10' X 14' -0", RF TRANSPARENT, CONCEALMENT STRUCTURE FOR CLEARWIRE TELECOMMUNICATIONS EQUIPMENT - FINNISH TO MATCH EXISTING BUILDING RE A-S (N) ANTENNA, MW & RRU MOUNTED TO HORIZ ANTENNA MOUNTING PIPES LOCATED AT TOP AND MIDDLE OF FRP STRUCTURE: A-5, A-0 (N) CLEARWIRE RF EQUIPMENT CABINET MOUNTED TO 2X6 SLEEPERS CONNECTED TO ROOF DECK RE: A-4, A -7 GRADE -225' SCALE: 1" = 20'-0" (11X17) SCALE: 1" = 10'-0" (22X34) (E) WAREHOUSE / DISTRIBUTION BUILDING III iii in m nI GRADE -225' (E) ACCESS LADDER RECEIVED CITY OF TUKWILA DEC 16 2009 PERMIT CENTER NOTE CONTRACTOR TO VERIFY RAD CENTERS AND SECTORS WITH RF ENGINEER PRIOR TO ANTENNA INSTALLATION. 10' 20' clearw're Cascadia\ PM 8760 122ND AVE, NE KIRKLAND, WA 98033 PH: (425) 828.1008 EXPIRES 6,/ PROJECT NO.: DRAWN BY: CHECKED BY: 2313 KKN JP SITE NO. WA- TAC0420 SITE NAME KENT BUSINESS SITE ADDRESS 1232 ANDOVER PARK W. TUKWILLA, WA 98188 APN: 3523049074 SHEET TITLE ELEVATIONS SHEET NO. A -3.0 3 SUBMITTAL I REVISIONS O. DATE DESCRIPTION 01 8-30-09 IINIT1 JP ZD SUBMITTAL SCALE: 1" = 20'-0" (11X17) SCALE: 1" = 10' (22X34) (N) CLEARWIRE ANTENNAS 43'-0" AGL (N) CLEARWIRE MICROWAVES 41'-0" AGL (E) ACCESS LADDER NORTH ELEVATION EAST ELEVATION 10 (N) 10 'X 10' X 14'-0", RF TRANSPARENT, CONCEALMENT STRUCTURE FOR CLEARWIRE TELECOMMUNICATIONS EQUIPMENT - FINNISH TO MATCH EXISTING BUILDING RE A-0 (N) ANTENNA, MW & RRU MOUNTED TO HORIZ. ANTENNA MOUNTING PIPES LOCATED AT TOP AND MIDDLE OF FRP STRUCTURE: A -5, A-0 (N) CLEARWIRE RF EQUIPMENT CABINET MOUNTED TO 2X6 SLEEPERS CONNECTED TO ROOF DECK RE: A -4, A -7 (N) CLEARWIRE ANTENNAS 43' -0" AGL (N) CLEARWIRE MICROWAVES 41'-0" AGL (E) WAREHOUSE / DISTRIBUTION BUILDING REVIEWED FOR CODE COMPLIANCE APPROVED DEC 2 4 2009 City of Tukwila i'WDING DIVISION 10'-0" (TYP) U (N) ACCESS DOOR RE: A-S (N) 10 'X 10' X 14' -0", RF TRANSPARENT, CONCEALMENT STRUCTURE FOR CLEARWIRE TELECOMMUNICATIONS EQUIPMENT - FINNISH TO MATCH EXISTING BUILDING RE A-S (N) ANTENNA, MW & RRU MOUNTED TO HORIZ ANTENNA MOUNTING PIPES LOCATED AT TOP AND MIDDLE OF FRP STRUCTURE: A-5, A-0 (N) CLEARWIRE RF EQUIPMENT CABINET MOUNTED TO 2X6 SLEEPERS CONNECTED TO ROOF DECK RE: A-4, A -7 GRADE -225' SCALE: 1" = 20'-0" (11X17) SCALE: 1" = 10'-0" (22X34) (E) WAREHOUSE / DISTRIBUTION BUILDING III iii in m nI GRADE -225' (E) ACCESS LADDER RECEIVED CITY OF TUKWILA DEC 16 2009 PERMIT CENTER NOTE CONTRACTOR TO VERIFY RAD CENTERS AND SECTORS WITH RF ENGINEER PRIOR TO ANTENNA INSTALLATION. 10' 20' clearw're Cascadia\ PM 8760 122ND AVE, NE KIRKLAND, WA 98033 PH: (425) 828.1008 EXPIRES 6,/ PROJECT NO.: DRAWN BY: CHECKED BY: 2313 KKN JP SITE NO. WA- TAC0420 SITE NAME KENT BUSINESS SITE ADDRESS 1232 ANDOVER PARK W. TUKWILLA, WA 98188 APN: 3523049074 SHEET TITLE ELEVATIONS SHEET NO. A -3.0 3 N WEST ELEVATION SOUTH ELEVATION (N) CLEARWIRE ANTENNAS 43' -0" AGL (N) CLEARWIRE MICROWAVES 41'-0• AGL 1a-a' (N) 10 'X 10' X 14'-0", RF TRANSPARENT, CONCEALMENT STRUCTURE FOR CLEARWIRE TELECOMMUNICATIONS EQUIPMENT - FINNISH TO MATCH EXISTING BUILDING RE: A-6 (N) ANTENNA, MW & RRU MOUNTED TO HORIZ. ANTENNA MOUNTING PIPES LOCATED AT TOP AND MIDDLE OF FRP STRUCTURE: A -5, A-6 (N) CLEARWIRE RF EQUIPMENT CABINET MOUNTED TO 2X6 SLEEPERS CONNECTED TO ROOF DECK RE: A-4, A-7 t7 d G (E) WAREHOUSE / DISTRIBUTION BUILDING SCALE: 1" = 20-0" (11X17) SCALE: 1" = 10'-0(22X34) (N) ANTENNA, MW & RRU MOUNTED TO HORIZ ANTENNA MOUNTING PIPES LOCATED AT TOP AND MIDDLE OF FRP STRUCTURE: A-5, A-0 (N) CLEARWIRE RF EQUIPMENT CABINET MOUNTED TO 2X6 SLEEPERS CONNECTED TO ROOF DECK RE: A -4, A-7 (N) CLEARWIRE ANTENNAS 43'-0• AGL (N) CLEARWIRE MICROWAVES 41' -0• AGL GRADE -22.5 RECEIVED CITY OF T pMALA lira 1 62009 PERMIT CENTER I SCALE: 1" = 20-0" (11X17) SCALE: 1" = 10'-0" (22X34) 20' FIEVIEWED FO CODE COMPLIANCE APPROVE DEC 2 4 2009 City of Tukwila BUILDING DIVISION (E) WAREHOUSE / DISTRIBUTION BUILDING 20' NOTE CONTRACTOR TO VERIFY RAD CENTERS AND SECTORS WITH RF ENGINEER PRIOR TO ANTENNA INSTALLATION. 10' 20' 10' (N) 10'X 10' X 14-0", RF TRANSPARENT, CONCEALMENT STRUCTURE FOR CLEARWIRE TELECOMMUNICATIONS EQUIPMENT - FINNISH TO MATCH EXISTING BUILDING RE: A-6 (E) ACCESS LADDER GRADE -225 20' clearw're Cascadia\ PM 8760 122ND AVE, NE KIRKLAND, WA 98033 PH: (425) 828 -1008 f XPIR =_S 6/9/ / f PROJECT NO.: DRAWN BY: CHECKED BY: 2313 KKN JP SUBMITTAL / REVISIONS IN O. DATE 1INITI DESCRIPTION 01 B-30-09 I JP I ZD SUBMITTAL SITE NO. WA- TAC0420 SITE NAME KENT BUSINESS SITE ADDRESS 1232 ANDOVER PARK W. TUKWILLA, WA 98188 APN: 3523049074 SHEET TITLE ELEVATIONS SHEET NO. A -3. EQUIPMENT PLAN OPTIONAL PLINTH HVAC UNIT EQUIPMENT CABINET 2' -1" EQUIP. CABINET w ; ,. . Irr a L POWER RECEPTACLE ELECTRICAL PANEL TELCO BOX GPS ANTENNA (PREFERRED LOCATION) NOTE: ANCHOR CABINET TO SLEEPERS & / OR OPTIONAL PLINTH WITH (4) 1/2" SIMPSON STRONG BOLT OR TITEN HD WITH 3-1/4" EMBED., ONE AT EACH CORNER. -SEE THIS SHEET FOR PLINTH DETAIL SCALE: 3/8" = 1'-0" (11X17) SCALE: 3/4" = 1'-0" (22X34) -ci ...:` :.. .... • DDB tfel/Bured I7ir;. aeti F tl•L• A4etiruml .•• 1•�.� .. '.a EQUIPMENT CABINET HVAC UNIT EQUIPMENT ELEVATIONS NOT USED TYP. GPS FIELD TO VERIFY LOCATION TELCO BOX 2 - 3"DIA SCH. 40 PVC TELCO CONDUIT EQUIPMENT CABINET HVAC' UNIT MOUNT EQUIP. CAB. TO (N) SLEEPERS & / OR OPTIONAL PLINTH TYP. GPS FIELD TO VERIFY LOCATION O EQUIPMENT CABINET ELEVATION O EQUIPMENT CABINET ELEVATION TYP. GPS C FIELD TO VERIFY LOCATION REVIEWED FOR CODE COMPLIANCE APPROVED DEC 2 4 2009 NOT USED TYP. GPS FIELD TO VERIFY LOCATION EQUIPMENT CABINET ELECTRICAL PANEL O EQUIPMENT CABINET ELEVATION O EQUIPMENT CABINET ELEVATION A POWER RECEPTACLE 2" DIA SCH. 40 PVC POWER CONDUIT TELCO BOX 2 - 3 "D1A SCH. 40 PVC TELCO CONDUIT EQUIPMENT CABINET HVAC UNIT SCALE: 3/8" = 1'-0" (11X17) SCALE: 3/4" = 1'-0" (22X34) 2313 KKN JP clearw're Cascadia\ PM 8760 AVE, NE KIRKLAND, WA 98033 PH: (425) 828 -1008 I PROJECT NO.: DRAWN BY: CHECKED BY: SITE NO. WA- TAC0420 SITE NAME KENT BUSINESS SITE ADDRESS 1232 ANDOVER PARK W. TUKWILLA, WA 98188 APN: 3523049074 SHEET TITLE EQUIPMENT DETAILS SHEET NO. A -4 SUBMITTAL / REVISIONS O. DATE DESCRIPTION 01 8-30-09 1INITI JP ZD SUBMITTAL EQUIPMENT PLAN OPTIONAL PLINTH HVAC UNIT EQUIPMENT CABINET 2' -1" EQUIP. CABINET w ; ,. . Irr a L POWER RECEPTACLE ELECTRICAL PANEL TELCO BOX GPS ANTENNA (PREFERRED LOCATION) NOTE: ANCHOR CABINET TO SLEEPERS & / OR OPTIONAL PLINTH WITH (4) 1/2" SIMPSON STRONG BOLT OR TITEN HD WITH 3-1/4" EMBED., ONE AT EACH CORNER. -SEE THIS SHEET FOR PLINTH DETAIL SCALE: 3/8" = 1'-0" (11X17) SCALE: 3/4" = 1'-0" (22X34) -ci ...:` :.. .... • DDB tfel/Bured I7ir;. aeti F tl•L• A4etiruml .•• 1•�.� .. '.a EQUIPMENT CABINET HVAC UNIT EQUIPMENT ELEVATIONS NOT USED TYP. GPS FIELD TO VERIFY LOCATION TELCO BOX 2 - 3"DIA SCH. 40 PVC TELCO CONDUIT EQUIPMENT CABINET HVAC' UNIT MOUNT EQUIP. CAB. TO (N) SLEEPERS & / OR OPTIONAL PLINTH TYP. GPS FIELD TO VERIFY LOCATION O EQUIPMENT CABINET ELEVATION O EQUIPMENT CABINET ELEVATION TYP. GPS C FIELD TO VERIFY LOCATION REVIEWED FOR CODE COMPLIANCE APPROVED DEC 2 4 2009 NOT USED TYP. GPS FIELD TO VERIFY LOCATION EQUIPMENT CABINET ELECTRICAL PANEL O EQUIPMENT CABINET ELEVATION O EQUIPMENT CABINET ELEVATION A POWER RECEPTACLE 2" DIA SCH. 40 PVC POWER CONDUIT TELCO BOX 2 - 3 "D1A SCH. 40 PVC TELCO CONDUIT EQUIPMENT CABINET HVAC UNIT SCALE: 3/8" = 1'-0" (11X17) SCALE: 3/4" = 1'-0" (22X34) 2313 KKN JP clearw're Cascadia\ PM 8760 AVE, NE KIRKLAND, WA 98033 PH: (425) 828 -1008 I PROJECT NO.: DRAWN BY: CHECKED BY: SITE NO. WA- TAC0420 SITE NAME KENT BUSINESS SITE ADDRESS 1232 ANDOVER PARK W. TUKWILLA, WA 98188 APN: 3523049074 SHEET TITLE EQUIPMENT DETAILS SHEET NO. A -4 MANUFACTURER: KATHREIN PART NUMBER 840 -10054 LENGTH: 42" WIDTH: 12.7" DEPTH: 2.8" WEIGHT: 20 lbs ANTENNA DETAILS 25.1" 3 I RRU DETAILS MANUFACTURER:HUAWEI PART NUMBER: RRU -3702 LENGTH: 19.1" (484 mm) WIDTH: 14.7" (374 mm) DEPTH: 6.2" (158 mm) MANUFACTURERANDREW PART NUMBER P2F -52 DIAMETER: 25.1" DEPTH: 8.2" OFFSET 12.7 WEIGHT: 18.71bs MOUNTING BRACKET FURNISHED WITH ANTENNA BY MANUFACTURER MICROWAVE DETAIL SCALE: NTS SCALE: NTS SCALE: NTS SCALE: NTS 3.74" 4 I GPS DETAIL (N) PIPE MOUNT SEE DETAIL 8/A-5. MICROWAVE ANTENNA REFERENCE DETAIL ALL MW ANTENNA INSTALLATION SHALL BE IN ACCORDANCE WITH MANUFACTURES SPECIFICATION AND CLEARWIRE DOCUMENT "METHODS AND PROCEDURES FOR CLEARWIRE BASE STATIONS. CLEARWIRE CONSTRUCTION INSTALLATION GUIDE - WIMAX", LATEST REVISION. 6 I M/W MOUNTING MAN UFACTURER:TRIMBLE PART NUMBER ACUTIME GOLD MOUNTING BRACKET: V9171 WEIGHT: 5.4 oz (154g) SCALE: NTS SCALE: NTS (E) PIPE MOUNT - CONTRACTOR TO VERIFY 3" DIA. MIN - SCHEDULE 40, HOT DIPPED GALVINIZED - IF REQUIRED REMOVE AND REPLACE 2 -3/8 "0X60" MOUNTING PIPE MICROWAVE MOUNTING HARDWARE BY MICROWAVE MANUFACTURER MICROWAVE (3 TYPICAL) ANTENNA MOUNTING HARDWARE BY ANTENNA MANUFACTURER RRU (3 TYPICAL) RRU MOUNTING HARDWARE BY RRU MANUFACTURER ANTENNA (3 TYPICAL) ANTENNA MOUNTING HARDWARE BY ANTENNA MANUFACTURER 3 "X5" ANGLE CROSSOVER 2 -3/8"0 OD TO 2 -3/8" OD HOT DIP GALVANIZED STEEL U -BOLTS INCLUDED ANDREW PART# XA -2020 NOTE: CONTRACTOR TO VERIFY RAD CENTERS AND SECTORS WITH RF ENGINEER PRIOR TO ANTENNA INSTALLATION. 2 -3/8 "0 SCH. 40 ANT. MOUNT PIPE W 1-3/8" UNITSTRUT SUPPORT CHANNEL @ TOP 8 MIDDLE, TYP, RE: A-6 ciea rw're Cascadia\ PM 8760 122ND AVE, NE KIRKLAND, WA 98033 PH: (425) 828 -1008 EXPIRES 6/9/ / ) SITE NO. WA- TAC0420 KENT BUSINESS SITE ADDRESS 1232 ANDOVER PARK W TUKWILLA, WA 98188 APN: 3523049074 SHEET TITLE ANTENNA DETAILS SHEET NO. ANTENNA MOUNTING SCALE: NTS SCALE: NTS SCALE: NTS SECTOR SECTION SCALE: 1/7 = 1'-0" (11X17) SCALE: 1" = 1'-0" (22X34) MOUNTING BRACKET FURNISHED WITH ANTENNA ALTERNATE IF NOT FURNISHED: KATHREIN SCALA UNIVERISAL TILT BRACKET ALL ANTENNA INSTALLATION SHALL BE IN ACCORDANCE WITH MANUFACTURES SPECIFICATION AND CLEARWIRE DOCUMENT "METHODS AND PROCEDURES FOR CLEARWIRE BASE STATIONS, CLEARWIRE CONSTRUCTION INSTALLATION GUIDE - WIMAX", LATEST REVISION. NOT USED REVIEWED FOR CODE COMPLIANCE IAPPRfvED DEC 2 4 tuud suBMRTAL. 1 REVISIONS I NC . DATE INIT DESCRIPTION 01 8-30-09 I JP ZD SUBMITTAL SUBMITTAL I REVISIONS 0. DATE DESCRIPTION 01 8-30-09 IINIT1 JP ZD SUBMITTAL 4 N io FRP L-GIRT PER DETAIL 1/ -. TYP. MW02 PANEL (MATCH EXISTING BUILDING) 3/810 STAINLESS STEEL LAG SCREW TO GIRT @ 18" O.C. (E) ROOF DECK 1 SECTION VIEW OUTRIGGER PER DR 2/- TYP. (2) 5/8"0 FRP THREADED ROD WI ISOPLAST NUTS, TYP. 4"X4"X3/8" FRP TUBE COLUMN, W/ COLUMN CAP, TYP. OF (4) 5/8"0 FRP THREADED ROD & NUT @ ALL FRP LOCATIONS 5/8"0 STEEL THRU BOLT PER DTL 3/ -, TYP. (E) ROOF DECK TUBE STEEL SLEEVE & BASE PLATE PER DTL 3/ -, TYP. SCALE: 1/2" = 1'-0" (11X17) SCALE: 1" = 1'-0" (22X34) 2 2 -318"0 SCH. 40 ANT. MOUNT PIPE W 1 -3/B" UNITSTRUT SUPPORT CHANNEL @ TOP & MIDDLE. TYP. REVIEWED FOR CODE COMPLIANCE * PgaflvWD DEC 2 4 L J9 City of Tukwila BUILDING DIV(S1Onl RECEIVED CITY OF TUKWILA DEC 16 2009 PERMIT CENTER SCALE: 12" = 1'-0" (11X17) SCALE: 1" = 1'-0" (22X34) 3 BASE PLATE DETAIL 3/8" THK GUSSET & ALL CORNERS, TYP. 4 "X4"X3/8" FRP TUBE COLUMN, W/ COLUMN CAP, TYP. OF (4) L4X4X3/8 FRP HORIZ. BRACING, TYP. 5/8 "0 FRP THREADED ROD & NUT @ ALL FRP LOCATIONS \ 3' WIDEx 4' TALL FRP ACCESS PANEL X4X3/8 FRP L-GIRT @ PANEL TOP & BOTTOM, TYP. LA4X4X3/8 FRP OUTRIGGER, TYP. MWO2 PANEL (MATCH EXISTING BUILDING) TOP VIEW SECTION "A" 2 1/4" 1 1/2" A A 1 1 3/16 518"0 THRU 2X 0 i 11/16 "0 THRU HSS4-1/2X4- 12X3/16 NOTE: BASE PLATE SECURE TO (N) 6"X8" W/ 5/8 "0 X 6" LAG BOLTS PLAN VIEW SCALE: 1" = 1'-0" (11X17) SCALE: 2" = 1'-0" (22X34) clea rw're Cascadia\ PM 8760 122ND AVE, NE KIRKLAND, WA 98033 PH: (425) 828 -1008 r 9 c 0 E >:PIR =S rrig���� PROJECT NO.: DRAWN BY: CHECKED BY: 2313 KKN JP SITE NO. WA- TAC0420 SITE NAME KENT BUSINESS SITE ADDRESS 1232 ANDOVER PARK W TUKWILLA, WA 98188 APN: 3523049074 SHEET TITLE STEALTH STRUCTURAL PLAN SHEET NO. A -6 (N) 2,44" BRACING SECURE TO (E) 2-k4" W/ A-34 CUPS (TYP) 3 3/4" N (TYP) EQUIPMENT CABINET HVAC UNIT 7 a (E) B-1 SECTION UNE (E) 8" CONC. WALL (N) HU610 -TF CUP TYP. 1/2"(3 X8" (§) EACH END OF 6x6 CABINET SUPPORT INTO 6x8 SLEEPER (N) 8X6 PT CABINET SUPPORT BM III (N) 8X8 SLEEPERS (FLASH AND ROOF OVER AS NECESSARY) Ill (N) 6"X10" BELOW III 1/2"0 THRD ROD (14" O.C. (TYP) (N) HUS810 HANGER (g 4X16 BEAM II (E) 4"X16" BASE PLATE : A-6 (E) 2"X4" 24" O.C. NOTE: SITE PLAN NOT FROM SURVEY. WE PLAN VIEW @ SHROUD ANCHORAGE SCALE: 3/8" = 1 (11X17) 0' SCALE: 3/4"" 1 (22X34) 1' 2 4' • • IIN 011 (E) ROOF T-8" RECEIVED OF TUK 111-1:1 6 2009 PERMIT CENTER RtVIEWED FOR CODE COMPLIANCE APPROVED DEC 2 4 2uu9 City of Tukwila BUILDING DIVISION SECURE 6x6 PT TO (N) 6")(8" PT W/ 1/2"0 x B" LAG BOLTS EACH END (N) 6X8 SLEEPERS (TYP) (N) 6X10 W/ HUS610 HANGER (HU610 - TF CONC WALL) (E) 4"X16" (E) 2"X4" (11 24" O.C. 6x10 BEAM BELOW CUT 2x4 PANEL FRAMING AS NECESSARY 1/2"0 THRD ROD (g) 24" 0.C. (TYP) (E) 8-3/4" X 27" GLB 2 ROOF SECTION VIEW AT SHROUD ANCHORAGE SCALE: 3/8' = 1'47' (11X17) S CALE: 3/4"" 1'-0" (22X34) clearw're Cascadia\ PM 8760 122ND AVE, NE KIRKLAND, WA 98033 PH: (425) 828-1008 - • 14) . • vt) s• I , ,/ 111101 Ea i lI 1110•14.V11401:17■M SUBMITTAL / REVISIONS Imo seelli inn milMIN:11:4gaINEMIl 111.11 111:50E•111 MIA 11W41111 SITE NO. WA-TAC0420 SITE NAME KENT BUSINESS SITE ADDRESS 1232 ANDOVER PARK W. TUKVVILLA, WA 98188 APN: 3523048074 SHEET TITLE ROOF PLAN SHEET NO. A-7 SUBMITTAL / REVISIONS O. IN DATE INIT DESCRIPTION 0 8-30-09 I JP 1 ZD SUBMITTAL CONTRACTOR GENERAL NOTES 1. CONTRACTOR WILL PROVIDE ALL LABOR, MATERIALS, TOOLS, EQUIPMENT, SAFETY EQUIPMENT, TRANSPORTATION, AND SERVICES NECESSARY TO COMPLETE ALL THE WORK OUTLINED IN ALL THE DRAWINGS, SPECIFICATIONS, SCOPE OF WORK., BILL OF MATERIALS, AND ANY OTHER DOCUMENT ISSUED BY CLENTS REPRESENTATIVE AND THE WIRELESS SERVICES COMPANY. 2. THE CONTRACTOR SHALL COMPLY WfTH ALL LOCAL AND NATIONAL CODES, LAWS, ORDINANCES, REGULATIONS, SAFETY REGULATIONS. ALL OSHA REGULATIONS, ALL PUBLIC AND MUNICIPAL AUTHORITIES, AND ANY UTILITY COMPANY REGULATIONS AND DIRECTIVES. 3. ALL MATERIALS SUPPLIED BY THE CLIENTS REPRESENTATIVE REPRESENTATIVE, AND THE CONTRACTOR, SHALL BE INSTALLED IN ACCORDANCE WITH ALL LOCAL AND NATIONAL CODES, LAWS, ORDINANCES, REGULATIONS AND PER MANUFACTURERS RECOMMENDATIONS. 4. ANY CONTRACTOR SUBMITTING BIDS ON ANY OF THE WORK IS REQUIRED TO VISIT EACH SITE PRIOR TO THE BID SUBMITTAL AND FAMILIARRE HIMSELF/HERSELF WITH THE EXISTING CONDITIONS AND UNDERSTAND THE SCOPE OF WORK INTENDED FOR THE PROJECT. THIS WILL BE PERFORMED AT THE CONTRACTORS EXPENSE. 5. THE DRAWINGS AND SPECIFICATIONS ARE A GENERAL DIRECTIVE FOR THE COP OF WORK EXACT DIMENSIONS AND LOCATIONS MAY CHANGE IN THE FIELD.' CONTRACTOR IS TO VERIFY THE DIMENSIONS AND LOCATIONS AND REPORT AND ALL DISCREPANCIES TO CLIENTS REPRESENTATIVE PRIOR TO COMMENC SPECIFICATIONS, DOES NOT EXCUSE R THE CONTRACTOR FROM COMPLETING E PROJECT AND IMPROVEMENTS IN ACCORDANCE WITH THE INTENT OF THESE DOCUMENTS. 8. ALL WORK AND MATERIALS FURNISHED BY THE CONTRACTOR SHALL HAVE A WRITTEN 18 MONTH WARRANTY STARTING AT THE ACCEPTANCE OF THE SITE FROM CLIENTS REPRESENTATIVE. 9. THE CONTRACTOR SHALL HAVE DESIGNATED A MANAGER ON SITE AT ALL TIMES THAT ANY WORK IS BEING PERFORMED. A SUB - CONTRACTOR IS NOT DEFINED AS A DESIGNATED MANAGER. 10. THE CONTRACTOR SHALL PROVIDE A SCHEDULED LIST OF ALL SUB - CONTRACTORS, WHICH SHALL INCLUDE ADDRESSES, CELL PHONE NUMBERS, HOME PHONE NUMBERS, VERIFICATION OF INSURANCE. ANY AND ALL PERTINENT LICENSES, AND AN ACCURATE SCHEDULE FOR THE PROJECT PRIOR TO THE ISSUANCE OF AN NTP. 11. THE CONTRACTOR IS TO KEEP A COMPLETE AND UP- TO-DATE SET OF THE DRAWINGS, SPECIFICATIONS, SCOPE OF WORK AND BILL OF MATERIAL ON THE SITE AT ALL TIMES. THIS WILL BE REFERENCED AS THE AS -BUILT DRAWINGS AND MUST BE KEPT CURRENT ON A DAILY BASIS. THIS IS IN ADDITION TO THE PERMIT SET. 12. A NEW AND CLEAN SET OF CONTRACT DOCUMENTS WILL BE ISSUED TO THE CONTRACTOR NEAR THE COMPLETION OF THE PROJECT TO BE USED TO TRANSFER THE INFORMATION FROM THE FIELD COPY OF AS -BUILT DRAWINGS TO THE NEW COPY. THIS NEEDS TO BE SUBMITTED TO CLIENTS REPRESENTATIVE WITH THE CLOSEOUT DOCUMENTS. 13. ON ANY CO -LOCATION SITE, THE CONTRACTOR AND ANY AND ALL ASSIGNS ARE NOT TO USE EXISTING POWER OR TAMPER WITH ANY EQUIPMENT BELONGING TO ANY OTHER CARRIER FAILURE TO ADHERE TO THIS WILL CAUSE IMMEDIATE DISMISSAL OF THE CONTRACTOR FROM THE PROJECT. 14. THE CONTRACTOR IS RESPONSIBLE FOR SCHEDULING ALL INSPECTIONS AND TESTING REQUIRED FOR EACH PROJECT. A 48 -HOUR NOTIFICATION TO CLIENTS REPRESENTATIVE IS REQUIRED FOR ALL INSPECTIONS AND TESTING. A FIELD COPY OF ALL INSPECTION AND TESTING REPORTS AS WELL AS TRUCK TICKETS MUST BE SUBMITTED TO CLIENTS REPRESENTATIVE WITHIN 24 HOURS OF THE INSPECTION OR TEST. 15. THE CONTRACTOR IS RESPONSIBLE TO VERIFY ALL MATERIAL ISSUED TO HIM/HER, AND TO REPORT ANY SHORTAGES AND DISCREPANCIES TO CLIENTS REPRESENTATIVE AT THE TIME OF ISSUANCE THE CONTRACTOR SHALL STORE THESE MATERIALS PROPERLY, ACCORDING TO THE MANUFACTURER'S RECOMMENDATIONS AND IN A MANNER THAT WILL NOT VOID THE WARRANTY ON ANY ITEM. IF ANY ITEM IS DAMAGED OR UNUSABLE DUE TO IMPROPER HANDLING AND STORAGE, THE CONTRACTOR WILL REPLACE TT AT HIS/HER EXPENSE 16. THE CONTRACTOR IS RESPONSIBLE TO FURNISH PROPER FACILITIES FOR THE WORKERS ON EACH PROJECT FOR THE DURATION OF THAT PROJECT. 17. THE CONTRACTOR IS RESPONSIBLE TO MAINTAIN THE PRESENT CONDITION OF ANY EXISTING BUILDINGS, LANDSCAPING, FENCING, EQUIPMENT, WALKS, DRIVES, AND ATTACHMENTS. IF ANY DAMAGE SHOULD OCCUR, THE CONTRACTOR IS RESPONSIBLE TO RESTORE THE DAMAGE TO A BETTER OR NEW CONDITION. ODE COMP1 A PP V PART 1 - PROJECT GENERAL NOTES 1.1 SCOPE OF WORK A. PROVIDE ALL LABOR, MATERIAL TOOLS, EQUIPMENT, TRANSPORTATION AND SERVICES NECESSARY FOR AND INCIDENTAL TO COMPLETION OF ALL WORK AS INDICATED ON THE DRAWINGS AND / OR AS SPECIFIED HEREIN. 12 DRAWING USE AND INTERPRETATION . A. THE DRAWINGS ARE DIAGRAMMATIC AND INDICATE THE GENERAL ARRANGEMENT OF SYSTEMS AND EQUIPMENT UNLESS INDICATED OTHERWISE BY DIMENSIONS OR DETAILS. EXACT EQUIPMENT LOCATIONS AND ROUTINGS, ETC. SHALL BE GOVERNED BY ACTUAL FIELD CONDITIONS AND /OR INSTRUCTIONS OF THE ENGINEER AND /OR CLIENTS REPRESENTATIVE. 1.3 COMPLETE SYSTEMS A. GENERAL FURNISH AND INSTALL ALL MATERIALS AS REQUIRED FOR COMPLETE SYSTEMS, WHETHER SPECIFICALLY INDICATED OR NOT. ALL SYSTEMS SHALL BE COMPLETELY ASSEMBLED, TESTED, ADJUSTED, DEMONSTRATED TO BE READY FOR OPERATION PRIOR TO CLIENTS REPRESENTATIVE'S ACCEPTANCE 1.4 S%QAES AND REGULATIONS FI LL: COMPLY WITH ALL GOVERNING FEDERAL, STATE AND LOCAL LAWS, ODES, RULES AND REGULATIONS. WHERE THE CONTRACT CEED THESE REQUIREMENTS, THE CONTRACT DOCUMENTS SHALL N 0 CASE SHALL WORK BE INSTALLED CONTRARY TO OR BELOW LEGAL STANDARDS. B. UTILITIES: COMPLY WITH ALL APPLICABLE RULES. RESTRICTIONS, AND DEC 4 2�`I:ICIU OF THE UTILITY COMPANIES SERVING THE PROJECT SITE-/ 6. ALL SITES SHALL BE KEPT CLEAN AND FREE OF DEBRIS ON A DAILY TRASH AND MATERIALS NO LONGER BEING USED AT THE SITE MUST BE R BASIS. EMO D AND PROPERLY DISPOSED OF ON A DAILY BASIS. ANY EXCESS MATERIAL WILL E RETURNED TO CLIENTS REPRESENTATIVE AND DELIVERED TO THE WAREHOU NG FACILITY PER THE DIRECTION OF CLIENTS REPRESENTATIVE. 7. THE CONTRACTOR SHALL NOT PROCEED WITH ANY WORK AT THE SITE PRIG T A NOTICE TO PROCEED (NW) HAS BEEN ISSUED AND A PRE - CONSTRUCTION • BUILDING DI STANDARDS MEETING AT THE SITE HAS TAKEN PLACE � T PUBLISHED STANDARDS OF THE FOLLOWING ASSOCIATIONS C. NON - COMPLIANCE: SHOULD ANY WORK BE PERFORMED WHICH IS FOUND NOT TO COMPLY WITH ANY OF THE ABOVE, CONTRACTOR SHALL PROVIDE ALL WORK AND City of TukiPiiit COSTS NECESSARY TO CORRECT THE DEFICIENCIES. ORGANIZATIONS SHALL BE FOLLOWED AND APPLIED WHERE APPLICABLE, AS MINIMUM REQUIREMENTS. 1) (ANSI) AMERICAN NATIONAL STANDARDS INSTITUTE. 2) (ASTM) AMERICAN SOCIETY FOR TESTING AND MATERIALS. 3) (ETL) ELECTRICAL TESTING LABORATORY. 4) (ICEA) INSULATED CABLE ENGINEERS ASSOCIATION. 5) (IEEE) INSTITUTE OF ELECTRICAL AND ELECTRONIC ENGINEERS. 6) (NBFU) NATIONAL BOARD OF FIRE UNDERWRITERS. 7) (NEMA) NATIONAL ELECTRICAL MANUFACTURERS ASSOCIATION. 8) (NESC) NATIONAL ELECTRIC SAFETY CODE. 9) (NFPA) NATIONAL FIRE PROTECTION ASSOCIATION. 10) (UL) UNDERWRITER'S LABORATORIES. 11) (BOCA) BUILDING OFFICIALS 8 CODE ADMINISTRATORS. 12) (NEC) NATIONAL ELECTRICAL CODE. 1.6 PERMITS A. GENERAL ALL PERMITS REQUIRED BY ALL APPLICABLE AGENCIES, WILL BE OBTAINED BY SUBCONTRACTOR. 1.7 MAINTAINING SITE CONDITIONS THE CONTRACTOR IS RESPONSIBLE FOR MAINTAINING A NEAT AND ORDERLY PROJECT SITE. REMOVE AND DISPOSE OFF SITE ALL RUBBISH, WASTE, LITTER AND ALL FOREIGN SUBSTANCES IN A LEGAL MANNER. REMOVE PETRO- CHEMICAL SPILLS, STAINS, AND OTHER FOREIGN DEPOSITS IN COMPLIANCE WITH OSHA REGULATIONS. RETURN ALL SURFACES TO ORIGINAL CONDITION. 1.8 CONCRETE 1, ALL MATERIALS, LABOR, AND METHODS SHALL CONFORM TO ALL APPLICABLE ASTM AND ACI STANDARDS AND REQUIREMENTS. IT IS THE CONTRACTOR'S RESPONSIBILITY TO INSURE THAT ALL STANDARDS ARE MET, AND TO BE ABLE TO PRODUCE THE VERIFICATION OF THESE ITEMS UPON REQUEST. 2. THE CONTRACTOR SHALL SCHEDULE ALL INSPECTIONS AT THE TESTING LABORATORY, AND INFORM CLIENTS REPRESENTATIVE WITHIN 24 HOURS OF THE INSPECTION OR TEST. THE TEST WILL INCLUDE SLUMP, AIR ENTRAINMENT, TEMPERATURE, AND TEST CYLINDERS. A TOTAL OF FIVE CYLINDERS SHALL BE TAKEN DURING EACH POUR OR FOR EACH 50 YARDS IF THE POUR IS OVER 50 YARDS. THE FIRST CYLINDER WILL BE BROKEN AT 3-1/2 DAYS, A SECOND AT 7 DAYS, A THIRD AT 14 DAYS AND A FOURTH AT 28 DAYS. THE LAST CYUNDER WILL BE KEPT SEPARATELY FOR FUTURE USE IF NECESSARY. 3. ALL CONCRETE FOR THE PROJECT SHALL HAVE A 28-DAY STRENGTH OF 4,000 PSI AND A SLUMP OF 5" MAXIMUM WITH THE MIXTURE PROPORTIONS MEETING THE ASTM AND ACI REQUIREMENTS. ALL ADMIXTURES AND MATERIALS USED FOR THE CONCRETE MIXTURE SHALL ALSO CONFORM TO THE PROPER ASTM REQUIREMENTS. RECEIVED CITY OF TUKWILA DEC 16 2009 4. THE CONTRACTOR WILL INSTRUCT THE CONCRETE SUPPLIER TO HAVE AN APPROVED PLASTICIZER ON THE TRUCK TO AID IN THE POURING AND PLACING OF PIERS AND FOUNDATIONS. 5. AIR ENTRAINING AGENT SHALL BE USED IN ANY CONCRETE EXPOSED TO FREEZING TEMPERATURES. 6. THE CONTRACTOR IS RESPONSIBLE FOR ALL EMBEDMENT LOCATIONS, SIZES, AND PROPER ANCHORING TO HOLD THE ITEMS IN PLACE ACCURATELY. 7. THE CONTRACTOR WILL SUPPLY AND USE A RELEASING AGENT ON ALL FORMS. ANY ATTACHMENT TO EXISTING CONCRETE AREAS WILL BE DONE WITH SMOOTH DOWELS AT 18" 0/C WITH A MINIMUM 6" EMBEDMENT IN EACH DIRECTION AND AN APPROVED BONDING AGENT TO BE APPLIED TO THE EXISTING SURFACE. 8. ALL EXPOSED CONCRETE WILL HAVE A UNIFORM FINISH AND BE SLOPED FOR DRAINAGE OFF THE SURFACE UNLESS OTHERWISE NOTED IN THE PLANS OR SPECIFICATIONS. 9. THE CONTRACTOR SHALL PROTECT THE CONCRETE FROM ANY ADVERSE WEATHER CONDITIONS; PREMATURE DRYING AND MECHANICAL INJURY TO INSURE PROPER CURING. 10. THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE USE AND CONTROL OF ANY MECHANICAL EQUIPMENT TO INSURE THE PROPER PLACEMENT OF THE CONCRETE TO PREVENT ANY VOIDS OR GAPS 1.9 METALS 1. ALL LABOR, MATERIALS, FABRICATION AND WORKMANSHIP SHALL CONFORM TO THE CODES AND STANDARDS OF ASTM AND AWS. 2. ALL WORK SHALL BE DONE BY A CERTIFIED WELDER THE CONTRACTOR SHALL SUBMIT A COPY OF THE CERTIFICATION TO CLIENTS REPRESENTATIVE 3. ALL STEEL USED SHALL BE HOT DIPPED GALVANIZED. 1.10 ANTENNAS AND CABLES 1. THE CONTRACTOR IS RESPONSIBLE FOR THE PROPER STORAGE AND HANDLING OF ALL MATERIALS ONCE THEY HAVE BEEN RELEASED FROM THE WAREHOUSE. 2. INSTALLATION OF ALL MATERIALS SHALL BE DONE IN STRICT ADHERENCE TO MANUFACTURER'S RECOMMENDATIONS. 3. TOWER TECHNICIANS MUST BE CURRENT ANDREWS CERTIFIED FOR CABLE CONNECTOR INSTALLATIONS. 4. THE CONTRACTOR SHALL RUN ALL LINES AND CONDUITS IN A NEAT, ORDERLY AND STRAIGHT FASHION PROVIDING ANCHORING AS RECOMMENDED BY THE MANUFACTURER AND WHEREVER NECESSARY TO SUPPORT THE LINES PROPERLY. 1.11 WARRANTIES PERMIT CENTER MONTHS OR AS STATED ELSEWHERE IN THE CONTRACT. 1. THE CONTRACTOR SHALL WARRANTY ALL GENERAL WORK FOR A MINIMUM OF 18 2. ROOF WARRANTY: ALL WORK ON ROOFS SHALL BE PERFORMED IN FULL COMPLIANCE WITH THE ROOF MANUFACTURER AND CONTRACTOR SHALL OBTAIN WRITTEN VERIFICATION FROM ROOF MANUFACTURER THAT THE WARRANTY REMAINS VALID AFTER CONSTRUCTION. 1.12 ELECTRICAL 1. THE CONTRACTOR IS RESPONSIBLE FOR ALL PERMITTING, FILING, AND FEES IN CONJUNCTION WITH THE PROJECT. 2. THE CONTRACTOR SHALL SCHEDULE ALL NECESSARY INSPECTIONS WITH THE PROPER AUTHORITIES AND INFORM THE PROJECT MANAGEMENT COMPANY 24- HOURS IN ADVANCE. ALL TICKETS AND INSPECTION VERIFICATIONS WILL BE SUBMITTED TO CLIENTS REPRESENTATIVE WITHIN 24 HOURS AFTER THE INSPECTION HAS TAKEN PLACE 3. ALL LABOR AND MATERIAL SHALL CONFORM TO ALL LOCAL, STATE, AND NATIONAL CODES, RULES, REGULATIONS AND STANDARDS. 4. ALL EQUIPMENT, WIRING, AND MATERIALS MUST HAVE A UL LABEL 5. ALL WORK SHALL BE DONE BY QUALIFIED AND EXPERIENCED JOURNEYMEN AND PERFORMED IN A WORKMANLIKE MANNER AND SHALL PROCEED IN AN ORDERLY MANNER SO AS NOT TO HOLD UP THE PROGRESS OF THE PROJECT. 6. THOROUGHLY TEST ALL LINES, FEEDERS, EQUIPMENT, AND DEVICES WITH MAXIMUM LOADS TO ASSURE PROPER OPERATION. 7. CONDUITS AND FITTINGS FOR OUTSIDE APPLICATIONS SHALL BE RIGID OR NON - METALLIC UNLESS OTHERWISE NOTED. CONDUITS AND FITTINGS FOR INSIDE BUILDING RUNS ABOVE CEILINGS SHALL BE EMT. SUPPORT ALL CONDUITS WITHIN 3 FEET OF ALL JUNCTION BOXES AND AT 8 -FOOT INTERVALS OR LESS AS NEEDED WITH APPROVED ANCHORING DEVICES. clearw're 8760 122ND AVE, NE KIRKL.4ND, WA 98033 PH: (425) 828 -1008 _.: • 1i r {k X r ti' 1 • d� $. allt , % `'SS r:r7 y j r . PROJECT NO.: DRAWN BY: CHECKED BY: 2313 KKN JP SITE NO. WA- TAC0420 SITE NAME KENT BUSINESS SITE ADDRESS 1232 ANDOVER PARK W. TUKWILLA, WA 98188 APN: 3523049074 SHEET TITLE GENERAL NOTES SHEET NO. GN -1 Cc. SUBMITTAL / REVISIONS NO.I DATE f INITI DESCRIPTION 01 8-30-09 JP ZD SUBMITTAL I ( 8. ALL WIRES SHALL BE COPPER; USE OF ALUMINUM CONDUCTORS WILL NOT BE PERMITTED. SEE ELECTRICAL PLANS FOR SIZING AND LOCATIONS. USE PROPER SIZE CONNECTORS PER LOCAL STATE, AND NATIONAL CODES. 9. CONDUCTOR LENGTHS SHALL BE CONTINUOUS FROM TERMINATION TO TERMINATION WITHOUT SPLICES. 10. PROVIDE PULL BOXES WHERE SHOWN AND WHERE REQUIRED BY CODES AND UTILITY COMPANIES. 11. ALL CONDUIT ROUGH IN SHALL BE COORDINATED WITH THE MECHANICAL EQUIPMENT TO AVOID LOCATION CONFLICTS. CONTRACTOR SHALL VERIFY ALL LOCATIONS. 12. ALL WIRES SHALL BE TAGGED AT ALL PULL BOXES, J- BOXES, EQUIPMENT BOXES, AND CABINETS WITH APPROVED PLASTIC TAGS. 13. ALL BREAKERS IN LOAD CENTER SHALL BE IDENTIFIED WITH TYPE WRITTEN LABELS NEATLY PLACED ALONG SIDE OF THE BREAKER. 14. ALL GROUND BUS BARS SHALL BE A MINIMUM SIZE OF 114" X 4" X 20" UNLESS ACCOMMODATE THE REQUIRED NUMBER OF GROUNDING CONNECTIONS. THE HARDWARE SECURING ALL GROUND BARS SHALL BOND THEM TO THE STRUCTURE TO WHICH THEY ARE FASTENED. 15. ANY PENETRATIONS THROUGH WALLS, CEILINGS, FLOORS, ROOFS OR ANY OTHER SURFACE SHALL BE CORE DRILLED AND CLOSED WITH A UL RATED FIRE SAFING ASSEMBLY. IF A FIRE RATING IS NOT REFERRED TO ON THE DRAWINGS, THEN THE CONTRACTOR SHALL ASSUME A 1 -HOUR RATING. 16. THE MATERIALS AND EQUIPMENT INFORMATION ON THESE DRAWINGS IS BASED ON THE BEST AVAILABLE INFORMATION AT THE TIME THE DRAWINGS WERE ISSUED. CHANGES MAY OCCUR, AND THE CONTRACTOR SHALL VERIFY ALL ITEMS PRIOR TO PLACEMENT, AND MAKE ANY CORRECTIONS WITHOUT FURTHER COST TO CLIENTS REPRESENTATIVE. 17. ALL UNDERGROUND CONDUITS SHALL BE SCHEDULE 40 PVC. ALL SWEEPS OR BENDS, AND ABOVE- GROUND CONDUITS SHALL BE RIGID GALVANIZED STEEL OR PVC SCHEDULE 80. ALL CONDUITS NOT TERMINATING INTO A CLOSED AREA MUST BE SEALED TO PREVENT ENTRY OF ANY MOISTURE OR FOREIGN OBJECTS. ALL CONDUIT RISERS TO INCLUDE SLIP TYPE EXPANSION JOINT. GROUNDING 1. THE CONTRACTOR SHALL VERIFY WITH CLIENTS REPRESENTATIVE THAT ALL CONDUIT SYSTEMS, EQUIPMENT, DEVICES, PANELS, LINES, TRAYS, BRIDGES, PLATFORMS, AND ANY /ALL ITEMS ARE GROUNDED PROPERLY. 2. THE GROUNDING SYSTEM CONNECTIONS SHALL BE MADE WITH EXOTHERMIC WELDS AND /OR MECHANICAL TWO-LUG COMPRESSION CONNECTORS AS INDICATED ON PLANS. USE ONLY STAINLESS STEEL SCREWS, BOLTS WASHERS, AND NUTS FOR FASTENING. 3. CLEAN SURFACES THOROUGHLY BEFORE APPLYING GROUND LUGS OR CLAMPS. IF SURFACE IS COATED, THE COATING MUST BE REMOVED DOWN TO THE BARE METAL AFTER THE COATING. HAS BEEN REMOVED, APPLY A NON - CORROSIVE APPROVED COMPOUND TO THE CLEANED SURFACE AND INSTALL LUGS OR CLAMPS. WHERE GALVANIZING IS REMOVED FROM METAL, IT SHALL BE PAINTED OR TOUCHED UP WITH COLD GALVANIZING PAINT SUCH AS GLAVMOX OR EQUAL 4. ALL CLAMPS, SLEEVES, AND SUPPORTS USED TO SUPPORT OR CHANNEL THE GROUNDING SYSTEM CONDUCTORS AND PVC CONDUITS SHALL BE PVC TYPE NON - CONDUCTIVE. DO NOT USE METAL BRACKETS OR SUPPORTS THAT WOULD FORM A COMPLETE RING AROUND ANY GROUNDING CONDUCTOR. 5. ALL GROUNDING CONNECTIONS SHALL BE COATED WITH T &B KOPR SHIELD ANTI -CORROSIVE AGENT. NO SUBSTITUTIONS ARE PERMITTED. VERIFY THE PRODUCT WITH CLIENTS REPRESENTATIVE PRIOR TO USAGE. 6. GROUND THE ANTENNA BASES, FRAMES, CABLE TRAYS AND RACKS, AND ANY OTHER METALLIC COMPONENTS WITH #2 GROUNDING CONDUCTORS, AND CONNECT TO THE SURFACE - MOUNTED GROUND BARS. CONNECTION DETAILS SHALL BE PERFORMED PER THE MANUFACTURER'S SPECIFICATIONS AND RECOMMENDATIONS. 7. THE ANTENNA CABLES SHALL BE GROUNDED AT THE TOP AND BOTTOM OF THE VERTICAL RUN FOR LIGHTNING PROTECTION. THE ANTENNA CABLE SHIELD SHALL BE BONDED TO A COPPER GROUND BUS AT THE LOWERMOST POINT OF A VERTICAL RUN JUST BEFORE IT BEGINS TO BEND TOWARD THE HORIZONTAL PLANE. WIRE RUNS TO GROUND SHALL BE KEPT AS STRAIGHT AND SHORT AS POSSIBLE. THE ANTENNA CABLE SHIELD SHALL BE GROUNDED JUST BEFORE ENTERING THE CELL CABINET. ANY ANTENNA CABLES OVER 200 FEET IN VERTICAL LENGTH SHALL ALSO BE EQUIPPED WITH ADDITIONAL GROUNDING AT MID-POINT. 8. THE CONTRACTOR, UPON COMPLETION OF THE GROUNDING SYSTEM, SHALL SCHEDULE A TEST OF THE SYSTEM. CLIENTS REPRESENTATIVE' REPRESENTATIVE WILL BE INFORMED 48 HOURS IN ADVANCE OF THE TEST. PART 2 - PRODUCTS 2.1 GENERAL A. GENERAL REQUIREMENTS: ALL MATERIALS AND EQUIPMENT SHALL BE IN ACCORDANCE WITH CONTRACT DOCUMENTS AND STANDARD PRODUCTS OF THE VARIOUS MANUFACTURERS, WITH ALL MATERIALS AND EQUIPMENT TO BE NEW, CLEAN, UNDAMAGED, AND FREE OF DEFECTS AND CORROSION. B. ACCEPTABLE PRODUCTS: THE PRODUCT OF A SPECIFIED OR APPROVED MANUFACTURER WILL BE ACCEPTABLE ONLY WHEN THE PRODUCT COMPLIES WITH OR IS MODIFIED AS NECESSARY TO COMPLY WITH ALL REQUIREMENTS OF THE CONTRACT DOCUMENTS. C. COMMON ITEMS: WHERE MORE THAN ONE OF ANY SPECIFIC ITEM IS REQUIRED, ALL SHALL BE OF THE SAME TYPE AND MANUFACTURER. D. UL USTING: ALL MATERIALS AND EQUIPMENT SHALL BE UNDERWRITERS LABORATORIES (UL) LISTED AND LABELED, WHERE UL STANDARDS AND LISTINGS EXIST FOR SUCH MATERIALS OR EQUIPMENT. 2.2 RACEWAY SYSTEMS A. RACEWAY SIZING: AS REQUIRED BY NEC (MINIMUM)1MTH OVERSIZED RACEWAYS AS INDICATED ON DRAWINGS. MINIMUM CONDUIT SIZE 3/4 - INCH, UNLESS INDICATED OTHERWISE. B. RACEWAY TYPES: RIGID GALVANIZED STEEL CONDUIT, ELECTRICAL METALLIC TUBING (EMT), FLEXIBLE STEEL CONDUIT, LIQUID -TIGHT FLEXIBLE STEEL CONDUIT, SCHEDULE 40 HEAVY WALL AND SCHEDULE 80 EXTRA - HEAVY WALL RIGID NON- METAWC (PVC) CONDUIT, CONFORMING TO APPUCABLE ANSI, NEMA AND UL STANDARDS. C. FITTINGS: ALL RACEWAY FITTINGS (EXCEPT FOR RIGID NON-METALLIC CONDUIT) TO BE STEEL OR MALLEABLE IRON, AND UL -LISTED FOR THE INTENDED APPLICATION. EMT FITTING TO BE COMPRESSION TYPE. D. OUTLET BOXES (SURFACE MOUNTED): CADMIUM PLATED CASTOR MALLEABLE IRON. E. PULL AND JUNCTION BOXES AND WIREWAYS: USE AS INDICATED AND REQUIRED. JUNCTION BOXES FOR GENERAL INDOOR USE (DRY LOCATIONS) TO BE OF GALVANIZED CODE GAUGE STEEL CONSTRUCTION MINIMUM 4" SQUARE x 1 1/2" DEEP WITH SCREW -ON COVERS. WIREWAYS TO BE UL LISTED, SHEET STEEL CONSTRUCTION WITH SCREW -ON COVERS. FOR EXTERIOR AND DAMP OR WET INDOOR LOCATIONS, USE BOXES AND WIREWAYS APPROVED FOR SUCH USE. F. PIPE SLEEVES: RIGID STEEL CONDUIT OR IRON PIPE G. CONDUIT SEALS FOR CAST -IN -PLACE CONCRETE APPLICATIONS - ACCEPTABLE MANUFACTURERS: 0-2/GEDNEY TYPE "FSK"; THUNDERLINE CORPORATION "LINK SEAL" WITH 'LINK SEAL WALL SLEEVE. FOR CORE -DRILLED AND PRE -CAST OPENING APPLICATIONS - ACCEPTABLE MANUFACTURERS: O-Z / GEDNEY TYPE "CSML" THUNDERUNE CORP. "LINK SEAL" H. SWEEPS: ALL SWEEPS FOR COMMUNICATION EQUIPMENT OR INTO CONCRETE PAD SHALL BE MIN. 24" RADIUS. 2.3 CONDUCTORS - 600 VOLT AND BELOW A GENERAL SINGLE - CONDUCTOR 98% CONDUCTIVITY, ANNEALED, UNCOATED COPPER CONDUCTORS WITH 600 -VOLT RATED TYPE "THHN/THWN' INSULATION. B. CONNECTORS: NYLON SHELL INSULATED METALLIC SCREW -ON CONNECTORS FOR #14 -#10 AWG, AND BOLTED PRESSURE OR COMPRESSION TYPE LUGS AND CONNECTORS WITH INSULATING COVERS FOR #8 AWG AND LARGER 2.4 HANGERS AND SUPPORTS A. GENERAL ALL HANGERS, SUPPORTS, FASTENERS AND HARDWARE SHALL BE HOT -DIPPED GALVANIZED OR EQUIVALENT CORROSION RESISTANCE BY TREATMENT, AND SHALL BE MANUFACTURED PRODUCTS DESIGNED FOR THE APPLICATION. B. TYPES: HANGERS, STRAPS, RISER SUPPORTS, CLAMPS, U- CHANNEL THREADED RODS, ETC. AS INDICATED OR REQUIRED. 2.5 ELECTRICAL IDENTIFICATION A. NAMEPLATES: THREE -LAYER LAMINATED PLASTIC WITH MINIMUM 3/16" HIGH WHITE ENGRAVED CHARACTERS ON BLACK BACKGROUND AND PUNCHED FOR MECHANICAL FASTENING. B. FASTENERS: SELF - TAPPING STAINLESS -STEEL SCREWS NUMBER 10-32 STAINLESS STEEL MACHINE SCREWS WITH NUTS AND FLAT LOCK WASHERS. C. UNDERGROUND WARNING TAPE: SIX -INCH WIDE POLYETHYLENE TAPE, PERMANENTLY BRIGHT COLORED WITH CONTINUOUS - PRINTED LEGEND INDICATING GENERAL TYPE OF UNDERGROUND LINE BELOW AND "CAUTION". COLORS AS FOLLOWS: 1) RED = ELECTRIC, 2) ORANGE = COMMUNICATIONS. D. MARKING PENS: PERMANENT, WATERPROOF, QUICK DRYING BLACK INK ACCEPTABLE MANUFACTURERS: SANFORD FINE POINT "SHARPIE," OR EQUAL E. WIRE TAGS: VINYL OR VINYL -CLOTH SELF - ADHESIVE WRAPAROUND TYPE INDICATING APPROPRIATE CIRCUIT NUMBER, ETC. 2.7 GROUNDING A. SYSTEM DESCRIPTION: GROUNDING NETWORK SYSTEM SHALL ESTABLISH AN EARTH RESISTANCE TO THE REFERENCE GROUND POINT NOT TO EXCEED 5 FOR BUILDING, CONSISTING OF BONDING OF STRUCTURE AND OTHER MET, OBJECTS INCLUDING GROUNDING ELECTRODES AND INTERCONNECTING CONDUCTORS. THIS SHALL BE PERFORMED WITH THE 3 POINT TEST METHO B. MATERIAL - INDICATED AS FOLLOWING: 1. WATER SERVICE METALLIC PIPE 2. BUILDING STEEL 3. CONDUCTORS: COPPER STRANDED OR SOLID TINNED BARE SIZE AS IND 4. GROUND RODS: 5/8" DIA. X 10'-0" LONG COPPER CLAD GROUND ROD 5. CHEMICAL GROUND RODS: XIT GROUND ROD 10'-0" STRAIGHT SHAFTTY 6. COMPRESSION: HYGROUND AS MANUFACTURED BY FCI BURNDY. CON SHALL BE PROTECTED FROM CORROSION AS MANUFACTURED BY ZRC C PRODUCTS CO., AS NEEDED. 7. CONNECTIONS: DOUBLE HOLE LUGS FOR ALL MECHANICAL CONNECTI 8. EXOTHERMIC: CADWELD WITH PROPER MOLDS 2.8 SAFETY SWITCHES A. GENERAL: HEAVY DUTY HORSEPOWER RATED, FULLY ENCLOSED, FUSIBLE (WITH REJECTION FUSE CLIPS) OR NON -FUSED AS INDICATED, QUICK -MAKE, QUICK BREAK SWITCHING MECHANISM INTERLOCKED WITH COVER, AND NEMA1 ENCLOSURE FOR DRY LOCATIONS, AND NEMA 3R ENCLOSURE FOR OUTDOOR LOCATIONS, UNLESS INDICATED OTHERWISE. SWITCHES TO BE LABELED AS "SUITABLE FOR USE AS SERVICE ENTRANCE EQUIPMENT", WHERE REQUIRED. B. RATINGS; VOLTAGE, PHASES, AMPERAGES AND FUSING AS INDICATED. C. IN THE FUSED CONFIGURATION, SWITCHES SHALL HAVE AN INTERRUPTING CAPACITY OF AT LEAST 100,000 AMPS SYMMETRICAL AT SIX HUNDRED (600) VOLTS WHEN USED WITH CLASS RK5 TIME DELAY CURRENT LIMITING FUSES, AND 200,000 AMPS SYMMETRICAL AT 600 VOLTS WHEN USED WITH CLASS RK1 CURRENT LIMITING FUSES. D. GUARDS: LINE SHIELD GUARDS TO PREVENT CONTACT WITH LIVE PARTS. E CONTACTS: SILVER ALLOY; SWITCH BLADES SHALL BE DE- ENERGIZED IN THE OPEN POSMON. F. LUGS: SOLDERLESS TYPE. G. REJECTION FUSE CLIPS: PROVIDE FOR FUSIBLE SWITCHES (30-600A) TO PREVENT THE INSTALLATION OF CLASS H AND CLASS K NON-CURRENT- LIMITING FUSES. H. ACCEPTABLE MANUFACTURER: GENERAL ELECTRIC, SQUARE D, SIEMENS, OR EQUIVALENT. 2.9 FUSES A. UL CLASS RK1, 250 VOLT OR 600 VOLT AS REQUIRED FOR SYSTEM VOLTAGE, DUAL ELEMENT, TIME DELAY, CURRENT - LIMITING, 200,000 AIC, AMPERE RATINGS AS INDICATED. SIZE AND QUANTITY AS INDICATED ON POWER DIAGRAM. B. ACCEPTABLE MANUFACTURERS: BUSSMANN "FUSETRON", OR EQUAL BY FERRAZ SHAWMUT. 2.10 CIRCUIT BREAKERS A. GENERAL MOLDED CASE WITH THERMAL AND MAGNETIC TRIPS UNLESS INDICATED OTHERWISE. MINIMUM 10,000 AMPS INTERRUPTING CAPACITY, HIGHER RATINGS AS INDICTED OR REQUIRED BY AVAILABLE FAULT CURRENT. B. CIRCUIT BREAKERS FOR EXISTING EQUIPMENT SHALL BE FROM THE SAME MANUFACTURER AS THE ORIGINAL EQUIPMENT. 2.11 LOAD CENTER / PANELBOARDS A TWO -ROW CIRCUIT BREAKER WITH MAINS, RATINGS AND BRANCH DEVICES AS INDICATED. B. MINIMUM 10,000 AIC FOR 208V/240V UNLESS OTHERWISE NOTED. C. LOCKABLE COVER, COPPER BUS. D. LOAD CENTER SHALL HAVE MAIN CIRCUIT BREAKER (LOCKABLE IN ON & OFF POSITIONS). E. COPPER BUS BARS (ALUMINUM COMPONENTS IN ELECTRICAL DEVICES IS PROHIBITED), ISOLATED NEUTRAL BUS AND FULL SIZE GROUNDING BUS. 2.12 DEVICES: A. SWITCHES: 20AMP, 120 -277 VOLTS, A.C. ONLY TOGGLE TYPE, SINGLE POLE, DOUBLE POLE, 3 -WAY, OR 4 -WAY TIMER STYLE AS INDICATED OR REQUIRED. F. ACCEPTABLE MANUFACTURERS: GENERAL ELECTRIC, SQUARE D, SIEMENS, OR EQUIVALENT. REVIEWED F CO DE COMPLIAN APPROV DEC 2 4 2009 ATED E CTIONS MICAL f N Cityof T ukwila UIIDIN DIV CITYOF LA D EC 1 6 2009 PERMIT CENTER clearw're O .� PROJECT NO.: 2313 DRAWN BY: KKN CHECKED BY: JP SITE NO. WA- TAC0420 SITE NAME KENT BUSINESS SITE ADDRESS 1232 ANDOVER PARK W TUKWILLA, WA 98188 APN: 3523049074 SHEET TITLE GENERAL NOTES SHEET NO. GN-2 B. RECEPTACLES: 20 AMP, 125V, NEMA 5-208V DUPLEX TYPE FOR INDOOR MOUNTED. USE STAINLESS STEEL COVER. FOR OUTDOOR OR WET LOCATION MOUNTED, USE DEVICE RATED FOR USE. PROVIDE GFCI TYPE WITH SOLID STATE GROUND FAULT SENSING 8 5 MA TRIP FOR OUTDOOR OR WET LOCATIONS. C. AUXILIARY POWER (GENERATOR INLET): PROVIDE 3 -POLE, 4W, 125/250 VOLT FLANGED INLET, BACKBOX AND CLOSURE PLUG AT EXTERIOR OF BUILDING WALL (APPLETON #AJA20033 -200RS WITH MATCHING BACKBOX AND CLOSURE PLUG). 2.13 CABLE TRAY A PROVIDE A COMPLETE CABLE TRAY SYSTEM WITH BENDS, FITTINGS. ACCESSORIES, ETC. AS REQUIRED. B. DESCRIPTION: ALUMINUM ALLOY CONSTRUCTION. TYPE: LADDER WITH 17 MAXIMUM SPACING. DEPTH: MINIMUM 4 ", WIDTH: AS INDICATED ON DRAWINGS, (MINIMUM 12" HORIZONTAL RUNS, MINIMUM 6" VERTICAL RUNS). SUPPORT SPAN: B FOOT MINIMUM, UNLESS OTHERWISE NOTED. LOADING: 100 POUNDS/FOOT. RADIUS: 36" MINIMUM, (SMALLER RADIUS MAY BE PERMITTED IF APPROVED BY CLIENTS REPRESENTATIVE). COVER: VENTILATED .063 ALUMINUM, PROVIDE WHERE INDICATED. C. GROUNDING: BOND ALL TRAY SECTIONS USING #2 AWG BARE COPPER GROUND. D. ACCEPTABLE MANUFACTURERS: NEWTON INSTRUMENTS OR EQUIVALENT 2.14 SURGE SUPPRESSION A PRODUCTS MANUFACTURED BY ATLANTIC SCIENTIFIC. B. FURNISHED BY CASCADIA. INSTALLED BY CONTRACTOR. 2.15 TRANSFORMER A GENERAL- PURPOSE DRY -TYPE TRANSFORMERS SHALL BE ACCORDING TO NEMA TR 1, FACTORY- ASSEMBLED, GENERAL - PURPOSE, AIR - COOLED. PROVIDE TWO TAPS, FOR DE- ENERGIZED TAP - CHANGING OPERATION. INSULATE WITH CLASS 220 INSULATION AND RATE FOR 150 DEGREES C RISE AT CONTINUOUS OPERATION AT RATED KVA B. TRANSFORMER SURFACE TEMPERATURE RISE TO BE LIMITED TO A MAXIMUM OF 65 DEGREES C. C. PROVIDE TERMINAL ENCLOSURE. WITH COVER, TO ACCOMMODATE PRIMARY AND SECONDARY COIL WINDING CONNECTIONS AND ELECTRICAL SUPPLY RACEWAY TERMINAL CONNECTOR. D. CUSHION TRANSFORMER COIL AND CORE ASSEMBLY FROM ENCLOSURE WITH VIBRATION ISOLATION SUPPORTS. E. PAINT WITH LIGHT GREY ENAMEL F. TRANSFORMER SHALL BE PAD MOUNTED (PROVIDE HOUSEKEEPING PAD ACCORDING TO MFRS RECOMMENDATIONS). PART 3 - EXECUTION 3.1 GENERAL A THE INSTALLATION OF ALL WORK SHALL BE IN ACCORDANCE WITH THE INTENT OF THE CONTRACT DOCUMENTS. B. INSTALLATION REQUIREMENTS: ALL MATERIALS AND EQUIPMENT SHALL BE INSTALLED AS RECOMMENDED BY THE RESPECTIVE MANUFACTURERS, BY MECHANICS EXPERIENCED AND SKILLED IN THEIR TRADE, IN A NEAT AND WORKMANLIKE MANNER IN ACCORDANCE WITH THE STANDARDS OF THE TRADE, AND SO AS NOT TO VOID ANY WARRANTY OF UL LISTING. C. ADMINISTRATION AND SUPERVISION: ALL WORK SHALL BE PERFORMED UNDER THE CONTRACTOR'S DIRECT SUPERVISION, USING SUFFICIENT AND QUALIFIED PERSONNEL AS NECESSARY TO COMPLETE THE WORK IN ACCORDANCE WITH THE PROGRESS SCHEDULE. THE CONTRACTOR SHALL ASSIGN ONE OR MORE COMPETENT SUPERVISORS WHO SHALL HAVE AUTHORITY TO ACCEPT AND EXECUTE ORDERS AND INSTRUCTIONS, AND WHO SHALL COOPERATE WITH THE OTHER CONTRACTORS AND SUBCONTRACTORS, THE ENGINEER, AND CLIENTS REPRESENTATIVE IN ALL MATTERS TO RESOLVE CONFLICTS AND AVOID DELAYS. D. MINIMUM MOUNTING HEIGHT: INSTALL EXPOSED RACEWAY AND ALL OTHER EQUIPMENT (EG. LIGHTING FIXTURES) WITH NOT LESS THAN T-6" CLEAR TO FINISHED FLOOR, UNLESS INDICATED OR APPROVED OTHERWISE, AND EXCLUDING RACEWAY AND EQUIPMENT MOUNTED ON WALLS. E. DIMENSIONS AND CLEARANCES: FIELD MEASURE ALL DIMENSIONS AND CLEARANCES AFFECTING THE INSTALLATION OF ELECTRICAL WORK, IN RELATION TO ESTABLISHED DATUM, BUILDING OPENINGS AND CLEARANCES, AND WORK OF OTHER TRADES, AS CONSTRUCTION PROGRESSES. 3.2 EXAMINATION 0. CONDITIONS VERIFICATION: EXAMINE THE AREAS AND CONDITIONS UNDER WHICH THE WORK IS TO BE PERFORMED, AND IDENTIFY ANY CONDITIONS DETRIMENTAL TO THE PROPER AND TIMELY COMPLETION OF THE WORK DO NOT PROCEED UNTIL UNSATISFACTORY CONDITIONS HAVE BEEN CORRECTED. 3.3 MOUNTING HEIGHTS A. GENERAL INDICATED HEIGHTS ARE MEASURED FROM THE CENTER OF THE DEVICE OUTLET BOX TO THE FINISHED FLOOR OR GRADE, UNLESS INDICATED OTHERWISE. REQUEST INSTRUCTIONS FOR MOUNTING HEIGHTS NOT INDICATED. B. DEVICES: SWITCHES - 48" A.F.F. I RECEPTACLES -18" A.F.F. I THERMOSTAT - 48" A.F.F. 3.4 HOLES, SLEEVES, AND OPENINGS A GENERAL PROVIDE ALL HOLES, SLEEVES, AND OPENINGS REQUIRED FOR THE COMPLETION OF WORK, AND RESTORE ALL DAMAGED SURFACES TO MATCH SURROUNDING SURFACES. MAINTAIN INTEGRITY OF ALL FIRE AND SMOKE RATED BARRIERS USING APPROVED FIRESTOPPING SYSTEMS. WHEN CUTTING HOLES OR OPENINGS, OR INSTALLING SLEEVES, DO NOT CUT, DAMAGE OR DISTURB STRUCTURAL ELEMENTS OR REINFORCING STEEL UNLESS APPROVED IN WRITING BY THE PROJECT STRUCTURAL ENGINEER B. CONDUIT PENETRATIONS: SIZE CORE DRILLED HOLES S SPACE OF NOT LESS THAN 1/4" AND NOT MORE THAN 1" IS CONDUIT. WHEN OPENINGS ARE CUT IN LIEU OF CORE DR. ROUGH OPENING. SIZE SLEEVES TO PROVIDE AN ANNULAR THAN 1/4" AND NOT MORE THAN 1" AROUND THE CONDUIT, AROUND SLEEVE TO MATCH SURROUNDING SURFACES. 3.5 RACEWAY SYSTEMS A UNLESS INDICATED OTHERWISE, USE RACEWAY TYPES ' FOLLOWS: B. OVERHEAD MOUNTING: ATTACH OVERHEAD MOUNTED EQUIPMENT TO STRUCTURAL FRAMEWORK OR SUPPORTING METAL FRAMEWORK DO NOT MAKE ATTACHMENTS TO STEEL ROOFING, STEEL FLOORING OR CEILING MINERAL TILE C. WALL MOUNTING: SUPPORT WALL MOUNTED EQUIPMENT BY MASONRY, CONCRETE BLOCK METAL FRAMING OR SUB - FRAMING. D. EXTERIOR WALLS: MOUNT ALL EQUIPMENT LOCATED ON THE INTERIOR OR EXTERIOR BUILDING WALLS, AT LEAST ONE INCH AWAY FROM WALL SURFACE, USING SUITABLE SPACERS. E. STRUCTURAL MEMBERS: DO NOT CUT, DRILL OR WELD ANY STRUCTURAL MEMBER EXCEPT AS SPECIFICALLY APPROVED BY THE ENGINEER. F. INDEPENDENT SUPPORT: DO NOT SUPPORT MATERIALS OR EQUIPMENT FROM OTHER EQUIPMENT, PIPING, DUCTWORK OR SUPPORTS FOR SAME. G. TEMPORARY CONDITIONS: DO NOT ATTACH TO OR SUPPORT ELECTRICAL WORK FROM REMOVABLE OR KNOCKOUT PANELS OR TEMPORARY WALLS OR PARTITIONS. H. RACEWAY SUPPORTS: RIGIDLY SUPPORT ALL RACEWAY WITH MAXIMUM SPACINGS PER NEC, AND SO AS TO PREVENT DISTORTION OF ALIGNMENT DURING PULLING OPERATION. USE APPROVED HANGERS, CLAMPS AND STRAPS FOR INDIVIDUAL RUNS. DO NOT USE PERFORATED STRAPS OR TIE WIRES. WHERE MULTIPLE PARALLEL RACEWAYS ARE RUN TOGETHER, USE TRAPEZE TYPE HANGER ARRANGEMENT MADE FROM U -CHANNEL AND ACCESSORIES, SUSPENDED BY THREADED RODS, AND ALLOW AT LEAST 25% SPARE CAPACITY FOR FUTURE INSTALLATION OF ADDITIONAL RACEWAYS. RIGIDLY ANCHOR VERTICAL CONDUITS SERVING FLOOR - MOUNTED OR "ISLAND" TYPE EQUIPMENT MOUNTED AWAY FROM WALLS WITH METAL BRACKET OR RIGID STEEL CONDUIT EXTENSION SECURED TO FLOOR. HEWED FOR COMPLIANCE DY DEC 2 4 2009 1) OUTDOORS, EXPOSED: RIGID GALVANIZED STEEL COND RESISTANT SCHEDULE 40, WHERE NOT SUBJECT TO PHYSI 2) LIQUID TIGHT FLEXIBLE STEEL CONDUIT: USE WHERE FL CONNECTIONS ARE REQUIRED IN DRY, DAMP, WET, OR OIL L- CONNECTIONS TO TRANSFORMERS, VIBRATING EQUIPMENT, EQUIPMENT REQUIRING MINOR ADJUSTMENTS IN POSITIONS, AND FOR FINAL CONNECTIONS TO ALL MOTORS AND SIMILAR EQUIPMENT. 3.6 HANGERS AND SUPPORTS A. GENERAL RIGIDLY SUPPORT AND SECURE ALL MATERIALS, RACEWAY AND EQUIPMENT TO BUILDING STRUCTURE USING HANGERS, SUPPORTS AND FASTENER SUITABLE FOR THE USE, MATERIALS AND LOADS ENCOUNTERED. PROVIDE ALL NECESSARY HARDWARE. PROVIDE CONDUIT SUPPORTS AT MAXIMUM 5 FEET ON CENTER 'AL of Tukwila iTJ Dlvlcln�o I. MISCELLANEOUS SUPPORTS: PROVIDE ANY ADDITIONAL STRUCTURAL SUPPORT STEEL BRACKETS, ANGLES, FASTENERS AND HARDWARE AS REQUIRED TO ADEQUATELY SUPPORT ALL ELECTRICAL MATERIALS AND EQUIPMENT. J. ONE HOLE STRAPS SHALL NOT BE USED FOR CONDUITS LARGER THAN 3/4 INCH. RECEIVED CITY OF TUKV ILA DEC 16 2009 PERMIT CENTER 3.7 EQUIPMENT CONNECTIONS A. VERIFICATION: OBTAIN AND REVIEW SHOP DRAWINGS, PRODUCT DATA AND MANUFACTURER'S INSTRUCTIONS FOR EQUIPMENT FURNISHED BY OTHERS. EXAMINE ACTUAL EQUIPMENT TO VERIFY PROPER CONNECTION LOCATIONS AND REQUIREMENTS. B. ROUGH -IN: PROVIDE ALL REQUIRED CONDUIT, BOXES, FITTINGS, WIRE, CONNECTORS AND MISCELLANEOUS ACCESSORIES, ETC., AS NECESSARY TO ROUGH IN AND MAKE THE FINAL CONNECTIONS TO ALL EQUIPMENT REQUIRING ELECTRICAL CONNECTIONS. IN GENERAL MOTORS AND EQUIPMENT SHALL BE WIRED IN CONDUIT TO A JUNCTION BOX (OR SAFETY SWITCH) NEAR THE UNIT, AND FROM THERE TO THE UNIT IN FLEXIBLE METAL OR LIQUID TIGHT FLEXIBLE STEEL CONDUIT. C. CONNECTIONS: PROVIDE PROPERLY SIZED OVERLOAD AND SHORT CIRCUIT PROTECTION FOR ALL EQUIPMENT CONNECTED, WHETHER FURNISHED UNDER THIS CONTRACT OR BY OTHERS. VERIFY PRIOR CONNECTIONS WITH MANUFACTURER'S PUBLISHED DIAGRAMS AND COMPLY WITH SAME VERIFY THAT EQUIPMENT IS READY FOR ELECTRICAL CONNECTIONS, WIRING AND ENERGIZATION, PRIOR TO PERFORMING SAME. D. CONTROL WIRING: PROVIDE ALL CONTROL WIRING TO REMOTE DEVICES OR EQUIPMENT, AS INDICATED OR REQUIRED. MODIFY EQUIPMENT CONTROL WIRING, INSTALL OR DISCONNECT JUMPERS, ETC., AS REQUIRED. 3.8 IDENTIFICATION A. GENERAL LOCATE NAMEPLATE MARKING, OR OTHER IDENTIFICATION MEANS ON OUTSIDE OF EQUIPMENT OR BOX FRONT COVERS WHEN ABOVE CEILINGS AND WHEN IN MECHANICAL OR ELECTRICAL EQUIPMENT ROOMS OR OTHER UNFINISHED AREAS, AND ON INSIDE OF FRONT COVER WHEN IN FINISHED ROOMS / AREAS. USE CONTRACT DOCUMENT DESIGNATIONS FOR IDENTIFICATION UNLESS INDICATED OTHERWISE. B. NAMEPLATES: PROVIDE NAMEPLATE ENGRAVED WITH EQUIPMENT DESIGNATION FOR EACH SAFETY SWITCH, PANELBOARD, TRANSFORMER, MOTOR STARTER, AND ALL OTHER EQUIPMENT, ETC. C. UNDERGROUND WARNING TAPE: DURING TRENCH BACKFILLING FOR EACH UNDERGROUND ELECTRICAL TELEPHONE, SIGNAL AND COMMUNICATIONS LINE, PROVIDE A CONTINUOUS UNDERGROUND WARNING TAPE LOCATED DIRECTLY ABOVE LINE, AT SIX TO EIGHT INCHES BELOW FINISHED GRADE D. MARKING PEN LABELING: MARK EACH JUNCTION AND PULL BOX INDICATING SOURCE DESIGNATION AND CIRCUIT NUMBER(S) FOR THE ENCLOSED CONDUCTORS. E. LABEL ALL WIRES AND CABLES AT EVERY POINT OF TERMINATION AND IN ALL PULL BOXES AND JUNCTION BOXES. FOR POWER CIRCUITS, APPLY WIRE TAGS INDICATING APPROPRIATE CIRCUIT OR FEEDER NUMBER TO EACH CONDUCTOR PRESENT IN DISTRIBUTION PANEL AND PANELBOARD GUTTERS, AND TO EACH CONDUCTOR IN PULL AND JUNCTION BOXES. F. LOAD CENTER CIRCUIT DIRECTORIES: AT COMPLETION OF PROJECT, ACCURATELY COMPLETE EACH PANELBOARD CIRCUIT DIRECTORY CARD, IDENTIFYING LOAD SERVED OR "SPARE" OR "SPACE" FOR EACH CIRCUIT POLE. WHEN MODIFYING, ADDING OR DELETING CIRCUITS AT AN EXISTING PANELBOARD, UPDATE THE EXISTING (OR PROVIDE NEW) CIRCUIT DIRECTORY CARD TO ACCURATELY REFLECT FINAL CONDITIONS. 3.9 GROUNDING SYSTEM A. EXAMINATION VERIFY THAT SURFACES ARE READY TO RECEIVE WORK AND THAT THE FIELD MEASUREMENTS ARE AS SHOWN ON SHOP DRAWINGS. B. INSTALLATION - INSTALL AS INDICATED ON THE DRAWINGS AND AS REQUIRED: 1) GROUNDING NETWORK SYSTEM SHALL INCLUDE ELECTRICAL TRENCHING, BACKFILL AND COMPACTION PER THIS SECTION; GROUNDING WIRE, GROUNDING ELECTRODES AND ALL NECESSARY MATERIALS AND LABOR REQUIRED TO COMPLETE THE SPECIFIED SYSTEM. 2) ALL GROUND CONNECTIONS SHALL CONFORM TO IEEE STD 837 AND /OR UL467 PROTECTED FROM CORROSION AS NOTED ON DWGS. USE CADWELD OR DOUBLE LUG FOR OUTDOORS ABOVE AND BELOW GRADE, INDOORS, AND ON ROOF INSTALLATIONS, AS INDICATED ON PLANS. 3) ALL CLAMP CONNECTIONS SHALL BE MADE ACCESSIBLE FOR INSPECTION. USE ONLY WHERE SPECIFIED. 4) ALL UNDERGROUND CONNECTIONS SHALL BE INSPECTED BY THE CLIENTS REPRESENTATIVES REPRESENTATIVE PRIOR TO BACKFILLING. 5) IF ROCK IS ENCOUNTERED, GROUND ROD SHALL BE INSTALLED IN A 2 INCH DIAMETER DRILLED HOLE TO THE REQUIRED DEPTH AND BACKFILLED WITH APPLICATIONS OF MAGNESIUM SULFATE OR COPPER SULFATE. 6) GROUNDING WIRE SHALL NOT BEND LESS THAN 90° IN ANY LOCATION WITH A MINIMUM BEND RADIUS OF 8". clearw're Cascadia\ PM 8760 122ND AVE, NE KIRKLAND, WA 98033 PH: (425) 828 -1008 PROJECT NO.: DRAWN BY: CHECKED BY: 2313 KKN JP SUBMITTAL! REVISIONS NO. 01 DATE 8-30-09 INIT JP DESCRIPTION ZD SUBMITTAL SITE NO. WA- TAC0420 SITE NAME KENT BUSINESS SITE ADDRESS 1232 ANDOVER PARK W. TUKWILLA, WA 98188 APN: 3523049074 SHEET TITLE GENERAL NOTES SHEET NO. GN -3 09 • 7) PROVIDE CORROSION PROOFING PAINT ON SURFACES EXPOSED DURING INSTALLATION. 8) ALL BELOW GROUND CONNECTIONS SHALL BE CADWELD. PROVIDE CORROSION PROTECTION TO CONNECTION AREA IF INDICATED. 9) ALL ABOVE GROUND CONNECTIONS SHALL BE BOLTED CLAMP. BURNDY CONNECTIONS SHALL NOT BE USED FOR EXTERIOR GROUNDING, UNLESS NOTED. 10) ALL GROUND CONNECTIONS TO THE GROUND BAR SHALL BE MADE WITH DOUBLE HOLE HYDRAULICALLY INDENTED LUGS, EXCEPT FOR TWO CADWELDS, AS SHOWN ON PLANS. 11) WHERE GROUND CONNECTIONS ARE MADE, THE CONTACT POINTS ARE TO BE CLEANED AND MADE FREE OF FOREIGN MATERIALS, SUCH AS PAINT AND CORROSION, TO ENSURE AN ADEQUATE BOND. 12) ALL GROUNDING AND BONDING INSTALLATIONS AND CONNECTIONS SHALL COMPLY WITH CLEARWIRE WIRELESS SERVICES ELECTRICAL AND GROUNDING SPECIFICATIONS. 13) ALL MECHANICAL GROUNDING CONNECTIONS MADE THROUGHOUT THESE DRAWINGS SHALL BE MADE WITH KOPR-SHIELD. THERE IS NO EQUIVALENT FOR THESE ANTIOXIDATION COMPOUNDS. NO OTHER COMPOUND WILL BE ACCEPTED. COAT ALL WIRES BEFORE LUGGING. COAT ALL SURFACES BEFORE CONNECTING. C. FIELD QUALITY CONTROL - FIELD INSPECTION AND TESTING WILL BE PERFORMED AS REQUIRED: 1) THE CONTRACTOR SHALL VERIFY THAT THE SYSTEM IS EFFECTIVELY GROUNDED, MEETS NEC ARTICLE 250 REQUIREMENTS, AND IS ACCEPTABLE TO THE LOCAL UTILITY AND LOCAL AUTHORITY HAVING JURSDICTION. 2) THE CONTRACTOR SHALL MAKE ALL MEASUREMENTS REQUIRED TO TEST THE GROUNDING NETWORK SYSTEM. SYSTEM SHALL BE TESTED AT THE TIME OF INSTALLATION. 3) THE GROUNDING NETWORK SYSTEM TEST PROCEDURE SHALL COMPLY WITH NFPA 78 THREE POINT TECHNIQUE FOR GROUND RESISTANCE, EXCEPT AS MODIFIED HEREIN. 4) CONTRACTOR SHALL VERIFY THE ADEQUACY OF THE INSTALLED SYSTEM. CONTRACTOR SHALL CONDUCT SITE RESISTANCE TO EARTH GROUNDING TESTING" SYSTEM 5) RECORD GROUND RESISTANCE PER CLEARWIRE WIRELESS COMPANY'S STANDARD. INSTALLED OHMS. 6) TEST SHALL BE WITNESSED BY CLIENTS REPRESENTATIVE SHALL ACHIEVE A GROUND RESISTANCE OF LESS THAN 5 OHMS. TEST RESULTS SHALL BE SUBMITTED ON THE "GROUND RESISTANCE TEST FORM" TO THE CLIENTS REPRESENTATIVE REPRESENTATIVE 7) SUBMIT 2 COPIES OF THE GROUND RESISTANCE TEST FORM TO THE CLIENTS REPRESENTATIVE REPRESENTATIVE. 3.10 CHECKOUT, TESTING, AND ADJUSTING A CORRECTION/REPLACEMENT: AFTER TESTING BY CONTRACTOR, CLIENTS REPRESENTATIVE, OR ENGINEER CORRECT ANY DEFICIENCIES, AND REPLACE MATERIALS AND EQUIPMENT SHOWN TO BE DEFECTIVE OR UNABLE TO PERFORM AT DESIGN OR RATED CAPACITY. B. POWER CONDUCTORS: CONTRACTOR SHALL CONDUCT A CONTINUITY & INSULATION TEST ON CONDUCTORS BETWEEN SERVICE DISCONNECT SWITCH 8 POWER CABINET. C. GROUNDING - IEEE FALL OF POTENTIAL TESTS: CONDUCT TEST WITH A AEMC MODEL #4500 TESTER. THE METHOD OF USING TWO AUXILIARY GROUND RODS (AS DESCRIBED IN I.E.E.E. STANDARD #81 - 1983, PART 1) SHALL BE USED. THE AUXILIARY TEST RODS MUST BE SUFFICIENTLY FAR AWAY FROM THE RODS SO THAT THE REGIONS IN WHICH THEIR RESISTANCE IS LOCALIZED DO NOT OVERLAP. 3.11 SYSTEMS DEMONSTRATION A. INSTRUCT CLIENTS REPRESENTATIVE'S REPRESENTATIVE(S) IN THE START -UP, OPERATION AND MAINTENANCE OF ALL ELECTRICAL SYSTEMS AND EQUIPMENT AS REQUESTED BY THE CLIENTS REPRESENTATIVE REPRESENTATIVE. 3.12 CLEANING AND TOUCH -UP PAINTING A GENERAL: PERIODICALLY REMOVE FROM THE PROJECT SITE, ALL WASTE, RUBBISH AND CONSTRUCTION DEBRIS ACCUMULATED FROM CONSTRUCTION OPERATIONS. THE PREMISES SHALL BE LEFT CLEAN AND FREE OF ANY DEBRIS AND UNUSED CONSTRUCTION MATERIALS PRIOR TO FINAL ACCEPTANCE. B. ELECTRICAL EQUIPMENT: REMOVE ALL DUST, DIRT, DEBRIS, MORTAR, WIRE SCRAPS, RUST, AND OTHER FOREIGN MATERIALS FORM THE INTERIOR AND EXTERIOR OF ALL ELECTRICAL EQUIPMENT AND ENCLOSURES, AND WIPE DOWN. CLEAN ACCESSIBLE CURRENT CARRYING ELEMENTS AND INSULATORS PRIOR TO ENERGIZING. 3.13 COAXIAL CABLE INSTALLATION A. THE COAXIAL CABLE SIZE SHALL BE AS SHOWN ON DRAWINGS. B. COAXIAL CABLE SUPPORTS. 1) SUPPORT COAXIAL CABLES INSIDE MONOPOLES WITH "KELLEM" GRIP TYPE PRODUCTS. 2) SECURE AND SUPPORT COAXIAL CABLES ON OPEN WAVEGUIDES STRUCTURAL TOWERS. 3) SECURE AND SUPPORT COAXIAL CABLES ON ICE BRIDGES AS INDICATED ON DRAWINGS. C. COAXIAL CABLE GROUNDING: 1) THE COAXIAL CABLES SHALL BE GROUNDED TO BUS BAR(S) AT THE ANTENNAS USING THE GROUNDING KITS AS SPECIFIED ON THE DRAWINGS. 2) THE COAXIAL CABLES SHALL BE GROUNDED TO A BUS BAR AT THE BOTTOM OF THE TOWER OR MONOPOLE USING THE GROUNDING KITS SPECIFIED ON THE DRAWINGS. 3) THE COAXIAL CABLES SHALL BE GROUNDED TO A BUS BM AT THE BULKHEADS USING THE GROUNDING KITS AS SPECIFIED ON THE DRAWINGS. 3.14 TELEPHONE SERVICE A GENERAL: ARRANGE WITH THE UTILITY COMPANY AND CLEARWIRE WIRELESS FOR A TIMELY INSTALLATION OF THE T -1 SERVICE. COMPLY WITH AND COORDINATE ALL REQUIREMENTS OF THE UTILITY COMPANY. B. CLIENTS REPRESENTATIVE WILL ORDER THE T -1 SERVICE. C. CONTRACTOR WILL ARRANGE FOR T -1 SERVICE INSTALLATION AND PAY FOR ASSOCIATED UTILITY CHARGES. 3.15 ELECTRICAL SERVICE A GENERAL: ARRANGE WITH THE UTILITY COMPANY AND CLEARWIRE WIRELESS SERVICES FOR A TIMELY INSTALLATION OF THE TEMPORARY ELECTRIC SERVICE (IF REQUIRED) AND PERMANENT ELECTRIC SERVICE COMPLY WITH AND COORDINATE ALL REQUIREMENTS OF THE UTILITY COMPANY. B. CLIENTS REPRESENTATIVE WILL ORDER THE ELECTRIC SERVICE. C. CONTRACTOR WILL ARRANGE FOR ELECTRIC SERVICE INSTALLATION AND PAY FOR ASSOCIATED UTILITY CHARGES. D. ARRANGE FOR AN INSPECTION OF THE ELECTRICAL SERVICE BY THE AUTHORITY HAVING JURISDICTION. OBTAIN A CERTIFICATE OF INSPECTION. FURNISH A COPY OF CERTIFICATE TO CLEARWIRE WIRELESS AND A COPY TO THE UTILITY COMPANY. E. COORDINATE METER SOCKET REQUIREMENTS WITH CLEARWIRE WIRELESS SERVICES AND ELECTRIC UTILITY. F. GROUNDING: PROVIDE GROUNDING ELECTRODE SYSTEM FOR THE SERVICE, PER THE NEC, PER UTILITY COMPANY REQUIREMENTS, AND AS INDICATED. G. SHORT CIRCUIT RATINGS: PROVIDE EQUIPMENT WITH HIGHER FAULT CURRENT RATINGS AS NEEDED TO MATCH UTILITY COMPANY AVAILABLE FAULT CURRENT. REVIEWED FOR CODE COMPLIANCE APPRME ) DEC 2 4 [uIJ City of Tukwila BUILDING flI lI Inwi RECEIVED CITY OF TUKWILA DEC 16 2009 PERMIT CENTER clear-w're Cascadia\ PM 8760 122ND AVE, NE KIRKLAND, WA 98033 PH: (425) 828 -1008 EXPIRES 6/ PROJECT NO.: 2313 DRAWN BY: KKN CHECKED BY: JP SITE NO. WA -TAC 0420 SITE NAME KENT BUSINESS SITE ADDRESS 1232 ANDOVER PARK W. TUKWILLA, WA 98188 APN: 3523049074 SHEET TITLE GENERAL NOTES SHEET NO. GN-4 SUBMITTAL / REVISIONS NO. DATE INIT DESCRIPTION 01 8 -30-09 JP ZD SUBMITTAL • 7) PROVIDE CORROSION PROOFING PAINT ON SURFACES EXPOSED DURING INSTALLATION. 8) ALL BELOW GROUND CONNECTIONS SHALL BE CADWELD. PROVIDE CORROSION PROTECTION TO CONNECTION AREA IF INDICATED. 9) ALL ABOVE GROUND CONNECTIONS SHALL BE BOLTED CLAMP. BURNDY CONNECTIONS SHALL NOT BE USED FOR EXTERIOR GROUNDING, UNLESS NOTED. 10) ALL GROUND CONNECTIONS TO THE GROUND BAR SHALL BE MADE WITH DOUBLE HOLE HYDRAULICALLY INDENTED LUGS, EXCEPT FOR TWO CADWELDS, AS SHOWN ON PLANS. 11) WHERE GROUND CONNECTIONS ARE MADE, THE CONTACT POINTS ARE TO BE CLEANED AND MADE FREE OF FOREIGN MATERIALS, SUCH AS PAINT AND CORROSION, TO ENSURE AN ADEQUATE BOND. 12) ALL GROUNDING AND BONDING INSTALLATIONS AND CONNECTIONS SHALL COMPLY WITH CLEARWIRE WIRELESS SERVICES ELECTRICAL AND GROUNDING SPECIFICATIONS. 13) ALL MECHANICAL GROUNDING CONNECTIONS MADE THROUGHOUT THESE DRAWINGS SHALL BE MADE WITH KOPR-SHIELD. THERE IS NO EQUIVALENT FOR THESE ANTIOXIDATION COMPOUNDS. NO OTHER COMPOUND WILL BE ACCEPTED. COAT ALL WIRES BEFORE LUGGING. COAT ALL SURFACES BEFORE CONNECTING. C. FIELD QUALITY CONTROL - FIELD INSPECTION AND TESTING WILL BE PERFORMED AS REQUIRED: 1) THE CONTRACTOR SHALL VERIFY THAT THE SYSTEM IS EFFECTIVELY GROUNDED, MEETS NEC ARTICLE 250 REQUIREMENTS, AND IS ACCEPTABLE TO THE LOCAL UTILITY AND LOCAL AUTHORITY HAVING JURSDICTION. 2) THE CONTRACTOR SHALL MAKE ALL MEASUREMENTS REQUIRED TO TEST THE GROUNDING NETWORK SYSTEM. SYSTEM SHALL BE TESTED AT THE TIME OF INSTALLATION. 3) THE GROUNDING NETWORK SYSTEM TEST PROCEDURE SHALL COMPLY WITH NFPA 78 THREE POINT TECHNIQUE FOR GROUND RESISTANCE, EXCEPT AS MODIFIED HEREIN. 4) CONTRACTOR SHALL VERIFY THE ADEQUACY OF THE INSTALLED SYSTEM. CONTRACTOR SHALL CONDUCT SITE RESISTANCE TO EARTH GROUNDING TESTING" SYSTEM 5) RECORD GROUND RESISTANCE PER CLEARWIRE WIRELESS COMPANY'S STANDARD. INSTALLED OHMS. 6) TEST SHALL BE WITNESSED BY CLIENTS REPRESENTATIVE SHALL ACHIEVE A GROUND RESISTANCE OF LESS THAN 5 OHMS. TEST RESULTS SHALL BE SUBMITTED ON THE "GROUND RESISTANCE TEST FORM" TO THE CLIENTS REPRESENTATIVE REPRESENTATIVE 7) SUBMIT 2 COPIES OF THE GROUND RESISTANCE TEST FORM TO THE CLIENTS REPRESENTATIVE REPRESENTATIVE. 3.10 CHECKOUT, TESTING, AND ADJUSTING A CORRECTION/REPLACEMENT: AFTER TESTING BY CONTRACTOR, CLIENTS REPRESENTATIVE, OR ENGINEER CORRECT ANY DEFICIENCIES, AND REPLACE MATERIALS AND EQUIPMENT SHOWN TO BE DEFECTIVE OR UNABLE TO PERFORM AT DESIGN OR RATED CAPACITY. B. POWER CONDUCTORS: CONTRACTOR SHALL CONDUCT A CONTINUITY & INSULATION TEST ON CONDUCTORS BETWEEN SERVICE DISCONNECT SWITCH 8 POWER CABINET. C. GROUNDING - IEEE FALL OF POTENTIAL TESTS: CONDUCT TEST WITH A AEMC MODEL #4500 TESTER. THE METHOD OF USING TWO AUXILIARY GROUND RODS (AS DESCRIBED IN I.E.E.E. STANDARD #81 - 1983, PART 1) SHALL BE USED. THE AUXILIARY TEST RODS MUST BE SUFFICIENTLY FAR AWAY FROM THE RODS SO THAT THE REGIONS IN WHICH THEIR RESISTANCE IS LOCALIZED DO NOT OVERLAP. 3.11 SYSTEMS DEMONSTRATION A. INSTRUCT CLIENTS REPRESENTATIVE'S REPRESENTATIVE(S) IN THE START -UP, OPERATION AND MAINTENANCE OF ALL ELECTRICAL SYSTEMS AND EQUIPMENT AS REQUESTED BY THE CLIENTS REPRESENTATIVE REPRESENTATIVE. 3.12 CLEANING AND TOUCH -UP PAINTING A GENERAL: PERIODICALLY REMOVE FROM THE PROJECT SITE, ALL WASTE, RUBBISH AND CONSTRUCTION DEBRIS ACCUMULATED FROM CONSTRUCTION OPERATIONS. THE PREMISES SHALL BE LEFT CLEAN AND FREE OF ANY DEBRIS AND UNUSED CONSTRUCTION MATERIALS PRIOR TO FINAL ACCEPTANCE. B. ELECTRICAL EQUIPMENT: REMOVE ALL DUST, DIRT, DEBRIS, MORTAR, WIRE SCRAPS, RUST, AND OTHER FOREIGN MATERIALS FORM THE INTERIOR AND EXTERIOR OF ALL ELECTRICAL EQUIPMENT AND ENCLOSURES, AND WIPE DOWN. CLEAN ACCESSIBLE CURRENT CARRYING ELEMENTS AND INSULATORS PRIOR TO ENERGIZING. 3.13 COAXIAL CABLE INSTALLATION A. THE COAXIAL CABLE SIZE SHALL BE AS SHOWN ON DRAWINGS. B. COAXIAL CABLE SUPPORTS. 1) SUPPORT COAXIAL CABLES INSIDE MONOPOLES WITH "KELLEM" GRIP TYPE PRODUCTS. 2) SECURE AND SUPPORT COAXIAL CABLES ON OPEN WAVEGUIDES STRUCTURAL TOWERS. 3) SECURE AND SUPPORT COAXIAL CABLES ON ICE BRIDGES AS INDICATED ON DRAWINGS. C. COAXIAL CABLE GROUNDING: 1) THE COAXIAL CABLES SHALL BE GROUNDED TO BUS BAR(S) AT THE ANTENNAS USING THE GROUNDING KITS AS SPECIFIED ON THE DRAWINGS. 2) THE COAXIAL CABLES SHALL BE GROUNDED TO A BUS BAR AT THE BOTTOM OF THE TOWER OR MONOPOLE USING THE GROUNDING KITS SPECIFIED ON THE DRAWINGS. 3) THE COAXIAL CABLES SHALL BE GROUNDED TO A BUS BM AT THE BULKHEADS USING THE GROUNDING KITS AS SPECIFIED ON THE DRAWINGS. 3.14 TELEPHONE SERVICE A GENERAL: ARRANGE WITH THE UTILITY COMPANY AND CLEARWIRE WIRELESS FOR A TIMELY INSTALLATION OF THE T -1 SERVICE. COMPLY WITH AND COORDINATE ALL REQUIREMENTS OF THE UTILITY COMPANY. B. CLIENTS REPRESENTATIVE WILL ORDER THE T -1 SERVICE. C. CONTRACTOR WILL ARRANGE FOR T -1 SERVICE INSTALLATION AND PAY FOR ASSOCIATED UTILITY CHARGES. 3.15 ELECTRICAL SERVICE A GENERAL: ARRANGE WITH THE UTILITY COMPANY AND CLEARWIRE WIRELESS SERVICES FOR A TIMELY INSTALLATION OF THE TEMPORARY ELECTRIC SERVICE (IF REQUIRED) AND PERMANENT ELECTRIC SERVICE COMPLY WITH AND COORDINATE ALL REQUIREMENTS OF THE UTILITY COMPANY. B. CLIENTS REPRESENTATIVE WILL ORDER THE ELECTRIC SERVICE. C. CONTRACTOR WILL ARRANGE FOR ELECTRIC SERVICE INSTALLATION AND PAY FOR ASSOCIATED UTILITY CHARGES. D. ARRANGE FOR AN INSPECTION OF THE ELECTRICAL SERVICE BY THE AUTHORITY HAVING JURISDICTION. OBTAIN A CERTIFICATE OF INSPECTION. FURNISH A COPY OF CERTIFICATE TO CLEARWIRE WIRELESS AND A COPY TO THE UTILITY COMPANY. E. COORDINATE METER SOCKET REQUIREMENTS WITH CLEARWIRE WIRELESS SERVICES AND ELECTRIC UTILITY. F. GROUNDING: PROVIDE GROUNDING ELECTRODE SYSTEM FOR THE SERVICE, PER THE NEC, PER UTILITY COMPANY REQUIREMENTS, AND AS INDICATED. G. SHORT CIRCUIT RATINGS: PROVIDE EQUIPMENT WITH HIGHER FAULT CURRENT RATINGS AS NEEDED TO MATCH UTILITY COMPANY AVAILABLE FAULT CURRENT. REVIEWED FOR CODE COMPLIANCE APPRME ) DEC 2 4 [uIJ City of Tukwila BUILDING flI lI Inwi RECEIVED CITY OF TUKWILA DEC 16 2009 PERMIT CENTER clear-w're Cascadia\ PM 8760 122ND AVE, NE KIRKLAND, WA 98033 PH: (425) 828 -1008 EXPIRES 6/ PROJECT NO.: 2313 DRAWN BY: KKN CHECKED BY: JP SITE NO. WA -TAC 0420 SITE NAME KENT BUSINESS SITE ADDRESS 1232 ANDOVER PARK W. TUKWILLA, WA 98188 APN: 3523049074 SHEET TITLE GENERAL NOTES SHEET NO. GN-4