Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Permit D09-264 - JAMAL MARKET - SHELVING
JAMAL MARKET 14643 TUKWILA INTERNATIONAL BL D09 -264 CityOf Tukwila Parcel No.: 0040000865 Permit Number: D09 -264 Address: 14643 TUKWILA INTERNATIONAL BL TUKW Issue Date: 02/10/2010 Suite No: Permit Expires On: 08/09/2010 Tenant: Name: JAMAL MARKET Address: 14643 TUKWILA INTERNATIONAL BL , TUKWILA WA Owner: Name: OBRIEN TIMOTHY M Address: 14217 59TH AVE S , TUKWILA WA 98188 Phone: Contact Person: Name: GIRL DEVARAJU Address: 4815 S 146 ST , TUKVVILA WA 98168 Phone: 425 -736 -2810 Contractor: Name: OWNER AFFIDAVIT - SHAHID HAQ Address: 1432 1ST AVE , SEATTLE WA 98101 Phone: 206 - 622 -1521 Contractor License No: Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Inspection Request Line: 206 431 - 2451 Web site: http: / /www.ci.tukwila.wa.us doc: IBC -10/06 DEVELOPMENT PERMIT DESCRIPTION OF WORK: REMOVE SOME INTERIOR BEARING AND NON - BEARING WALLS FOR SHELVING INTERNATIONAL GROCERY STORE. EXISTING USE WAS MEXICAN GROCERY STORE Value of Construction: $10,000.00 Fees Collected: $442.74 Type of Fire Protection: NONE International Building Code Edition: 2006 Type of Construction: V -B Occupancy per IBC: 0019 * * continued on next page ** Expiration Date: D09 -264 Printed: 02 -10 -2010 Public Works Activities: Channelization / Striping: N Curb Cut / Access / Sidewalk / CSS: N City oikI'ukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Inspection Request Line: 206 - 431 - 2451 Web site: http: / /www.ci.tukwila.wa.us Permit Number: D09 - 264 Issue Date: 02/10/2010 Permit Expires On: 08/09/2010 Fire Loop Hydrant: N Number: 0 Size (Inches): 0 Flood Control Zone: Hauling: N Start Time: End Time: Land Altering: Volumes: Cut 0 c.y. Fill 0 c.y. Landscape Irrigation: Moving Oversize Load: Start Time: End Time: Sanitary Side Sewer: Sewer Main Extension: Private: Public: Storm Drainage: Street Use: Profit: N Non - Profit: N Water Main Extension: Private: Public: Water Meter: N Permit Center Authorized Signature: Signature: -� Print Name: ) U A a doc: IBC -10/06 Date: ` 0 -- ( V I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this development permit. Date: �— \ o 1 \ This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. D09 -264 Printed: 02 -10 -2010 1: ** *BUILDING DEPARTMENT CONDITIONS * ** • • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us PERMIT CONDITIONS Parcel No.: 0040000865 Permit Number: D09 -264 Address: 14643 TUICWILA INTERNATIONAL BL TUKW Status: ISSUED Suite No: Applied Date: 12/17/2009 Tenant: JAMAL MARKET Issue Date: 02/10/2010 2: No changes shall be made to the approved plans unless approved by the design professional in responsible charge and the Building Official. 3: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center (206/431- 3670). 4: All permits, inspection records, and approved plans shall be at the job site and available to the inspectors prior to start of any construction. These documents shall be maintained and made available until final inspection approval is granted. 5: All construction shall be done in conformance with the approved plans and the requirements of the International Building Code or International Residential Code, International Mechanical Code, Washington State Energy Code. 6: Insulating materials, where exposed as installed in buildings of any type of construction, shall have a flame spread index of not more than 25 and a smoke development index of not more than 450. Where facings are installed in concealed spaces in buildings of Type HI, IV, or V construction, the flame spread and smoke - developed limitations do not apply to facings, that are installed behind and in substantial contact with the unexposed surface of the ceiling, wall or floor finish. 7: Notify the City of Tukwila Building Division prior to placing any concrete. This procedure is in addition to any requirements for special inspection. 8: All wood to remain in placed concrete shall be treated wood. 9: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the Cityof Tukwila Permit Center. 10: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206- 431 - 3670). 11: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. 12: All food preparation establishments must have Seattle /King County Department of Public Health sign -off prior to opening or doing any food processing. Arrangements for final Health Department inspection shall be made by calling Seattle/King County Department of Public Health, (206/296- 4928), at least three working days prior to desired inspection date. On work requiring Health Department approval, it is the contractor's responsibility to have a set of plans approved by the agency on the job site. 13: ** *FIRE DEPARTMENT CONDITIONS * ** doc: Cond -10/06 D09 -264 Printed: 02 -10 -2010 • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us 14: The attached set of building plans have been reviewed by the Fire Prevention Bureau and are acceptable with the following concerns: 15: The total number of fire extinguishers required for an ordinary hazard occupancy with Class A fire hazards is calculated at one extinguisher for each 1,500 sq. ft. of area. The extinguisher(s) should be of the "All Purpose" (2A, 20B:C) dry chemical type. Travel distance to any fire extinguisher must be 75' or less. (IFC 906.3) (NFPA 10, 3 -2.1) 16: Portable fire extinguishers, not housed in cabinets, shall be installed on the hangers or brackets supplied. Hangers or brackets shall be securely anchored to the mounting surface in accordance with the manufacturer's installation instructions. Portable fire extinguishers having a gross weight not exceeding 40 pounds (18 kg) shall be installed so that its top is not more than 5 feet (1524 mm) above the floor. Hand -held portable fire extinguishers having a gross weight exceeding 40 pounds (18 kg) shall be installed so that its top is not more than 3.5 feet (1067 mm) above the floor. The clearance between the floor and the bottom of the installed hand -held extinguishers shall not be less than 4 inches (102 mm). (IFC 906.7 and IFC 906.9) 17: Fire extinguishers shall not be obstructed or obscured from view. In rooms or areas in which visual obstruction cannot be completely avoided, means shall be provided to indicate the locations of the extinguishers. (IFC 906.6) 18: Extinguishers shall be located in conspicuous locations where they will be readily accessible and immediately available for use. These locations shall be along normal paths of travel, unless the fire code official determines that the hazard posed indicates the need for placement away from normal paths of travel. (IFC 906.5) 19: Fire extinguishers require monthly and yearly inspections. They must have a tag or label securely attached that indicates the month and year that the inspection was performed and shall identify the company or person performing the service. Every six years stored pressure extinguishers shall be emptied and subjected to the applicable recharge procedures. If the required monthly and yearly inspections of the fire extinguisher(s) are not accomplished or the inspection tag is not completed, a reputable fire extinguisher service company will be required to conduct these required surveys. (NFPA 10, 4 -3, 4 -4) 20: Egress doors shall be readily openable from the egress side without the use of a key or special knowledge or effort. (IFC 1008.1.8.3 subsection 2.2) 21: Dead bolts are not allowed on auxiliary exit doors unless the dead bolt is automatically retracted when the door handle is engaged from inside the tenant space. (IFC Chapter 10) 22: Door handles, pulls, latches, locks and other operating devices on doors required to be accessible by Chapter 11 of the International Building Code shall not require tight grasping, tight pinching or twisting of the wrist to operate. (IFC 1008.1.8.1) 23: Exit hardware and marking shall meet the requirements of the International Fire Code. (IFC Chapter 10) 24: Exits and exit access doors shall be marked by an approved exit sign readily visible from any direction of egress travel. Access to exits shall be marked by readily visible exit signs in cases where the exit or the path of egress travel is not immediately visible to the occupants. Exit sign placement shall be such that no point in an exit access corridor is more than 100 feet (30,480 mm) or the listed viewing distance for the sign, whichever is less, from the nearest visible exit sign. (IFC 1011.1) 25: Every exit sign and directional exit sign shall have plainly legible letters not less than 6 inches (152 mm) high with the principal strokes of the letters not less than 0.75 inch (19.1 mm) wide. The word "EXIT" shall have letters having a width not less than 2 inches (51 mm) wide except the letter "I ", and the minimum spacing between letters shall not be less than 0.375 inch (9.5 mm). Signs larger than the minimum established in section 1011.5.1 of the International Fire Code shall have letter widths, strokes and spacing in proportion to their height. The word "EXIT" shall be in high contrast with the background and shall be clearly discernible when the exit sign illumination means is or is not energized. If an arrow is provided as part of the exit sign, the construction shall be such that the arrow direction cannot be readily changed. (IFC 1011.5.1) doc: Cond -10/06 D09 -264 Printed: 02 -10 -2010 • • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http://www.ci.tukwila.wa.us 26: Exit signs shall be illuminated at all times. To ensure continued illumination for a duration of not less than 90 minutes in case of primary power loss, the sign illumination means shall be connected to an emergency power system provided from storage batteries, unit equipment or on -site generator. (IFC 1006.1, 1006.2, 1006.3) 27: Means of egress, including the exit discharge, shall be illuminated at all times the building space served by the means of egress is occupied. The means of egress illumination level shall not be less than 1 foot -candle (11 lux) at the floor level. The power supply for the means of egress illumination shall normally be provided by the premise's electrical supply. In event of a power failure an emergency power system shall provide power for a duration of not less than 90 minutes and shall consist of storage batteries, unit equipment or on -site generator. (IFC 1006.1, 1006.2, 1006.3) The path of egress shall require emergency lighting until exit discharge is accomplished. 28: Aisles leading to required exits shall be provided from all portions of the building and the required width of the aisles shall be unobstructed. (IFC 1013.4) 29: All electrical work and equipment shall conform strictly to the standards of the National Electrical Code. (NFPA 70) 30: The maximum flame spread class of finish materials used on interior walls and ceilings shall not exceed that set forth in Table No. 803.5 of the International Building Code. 31: New and existing buildings shall have approved address numbers, building numbers or approved building identification placed in a position that is plainly legible and visible from the street or road fronting the property. These numbers shall contrast with their background. Address numbers shall be Arabic numbers or alphabet letters. Numbers shall be a minimum of 4 inches (102mm) high with a minimum stroke width of 0.5 inch (12.7mm). (IFC 505.1) 32: Contact The Tukwila Fire Prevention Bureau to witness all required inspections and tests. (City Ordinances #2050 and #2051) 33: Any overlooked hazardous condition and/or violation of the adopted Fire or Building Codes does not imply approval of such condition or violation. 34: These plans were reviewed by Inspector 511. If you have any questions, please call Tukwila Fire Prevention Bureau at (206)575 -4407. doc: Cond -10/06 * * continued on next page ** D09 -264 Printed: 02 -10 -2010 • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us I hereby certify that I have read these conditions and will comply with them as outlined. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provision of any other work or local laws regulating construction or the performance of work. Signature: \-\ G.�1_ Print Name: doc: Cond -10/06 Date: .-*2 \ 6 ` 1 0 D09 -264 Printed: 02 -10 -2010 • CITY OF TUKWILA Community Development Department Public Works Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www.citukwila.wa.us Tenant Name: 6F1 Wn' L ` t1Lv V—u+ 27tr1 bevy rck) 0 Mailing Address: 4%. 1 S ' 1 6:7-k4 i �t s cq Name: E -Mail Address: t '7 2. akoa v VIA •l GENERAL CONTRACTOR INFORMATION — (Contractor Information for Mechanical (pg 4) for Plumbing and Gas Piping (pg 5)) Company Name: Mailing Address: E -Mail Address: Revised: 1 -2009 bh • Building Permit No. bo q -..2.. ip 9 Mechanical Permit No. Plumbing/Gas Permit No. Public Works Permit No. Project No. 1 R s 0q 1 Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. * *Please Print ** SITE LOCATION \ King Co Assessor's Tax No.: 0 64t66o n $(o S Site Address: I 41 i ( 4(,45 `roLailk l 6 imeibtie s sun 1� U t Floor: New Tenant: ❑ Yes ❑ ..No Property Owners Name: Mailing Address: City (For office use only) State Z ip CONTACT PERSON - who do we contact when your permit is ready to be issued Day Telephone: +2s- 730-SS v )c 6 /6 2 City ��ppyy�� State Fax Number: Z ip Company Name: Mailing Address: City State Zip Contact Person: Day Telephone: E -Mail Address: Fax Number: Contractor Registration Number: Expiration Date: ARCHITECT OF RECORD - All plans must be wet stamped by Architect of Record Company Name: Mailing Address: State City Contact Person: Day Telephone: E -Mail Address: Fax Number: Zip ENGINEER OF RECORD - All plans must be wet stamped by Engineer of Record S �oa av i( ok‘ Pot 1 41 WQr Wfr 4100 Zip Contact Person: f° l A44. Vl Day Telephone: 45_ 441111 h eh ?INCe,ivl C a wait OL4,Fax Number: 'ZOO- �'1 4 j - 5332.. H:WpplicationsWorms- Applications On Line\2009 Applications\ 009 - Permit applicafic Page 1 of 6 BUILDING PERMIT INFOION — 206 - 431 -3670 Valuation of Project (contractor's bid price): $ 10 00 D Scope of Work (please provide detailed information): R e m ov\P. _C crn e I n 1 LOOM Vi e o"` C .A„d ko ) e . kAm., to- is Y 4-s C a v` P .fl -ore . � Will there be new rack storage? ❑ Yes CI H:\Applications \Forms - Applications On Line\2009 Applications \I -2009 - Permit Applicanon.doc Revised: 1 -2009 bh Existing Building Valuation: $ 12- 0 0 .. No If yes, a separate permit and plan submittal will be required. Provide All Building Areas in Square Footage Below PLANNING DIVISION: Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) *For an Accessory dwelling, provide the following: Lot Area (sq ft): "T q- 2. I CO Floor area of principal dwelling: 2- L-P U Floor area of accessory dwelling: *Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard: i S Compact: Handicap: 2- Will there be a change in use? ❑ Yes Er No If "yes ", explain: FIRE PROTECTION/HAZARDOUS MATERIALS: ❑ Sprinklers ❑ Automatic Fire Alarm 111' None ❑ Other (specify) Will there be storage or use of flammable, combustible or hazardous materials in the building? ❑ Yes No If `yes', attach list of materials and storage locations on a separate 8 -1/2 "x 11" paper including quantities and Material Safety Data Sheets. SEPTIC SYSTEM ❑ On -site Septic System - For on -site septic system, provide 2 copies of a current septic design approved by King County Health Department. Page 2 of 6 Existing Interior Remodel Addition to Existing Structure New Type of Construction per IBC Type of Occupancy per IBC 1 Floor 2 4 L t S -- v-v - - - , - o p 5 -13 Gi as yam 2nd Floor 3 Floor Floors thru Basement Accessory Structure* Attached Garage Detached Garage Attached Carport Detached Carport Covered Deck -- - - - - -- -- -- - - - - Uncovered Deck BUILDING PERMIT INFOION — 206 - 431 -3670 Valuation of Project (contractor's bid price): $ 10 00 D Scope of Work (please provide detailed information): R e m ov\P. _C crn e I n 1 LOOM Vi e o"` C .A„d ko ) e . kAm., to- is Y 4-s C a v` P .fl -ore . � Will there be new rack storage? ❑ Yes CI H:\Applications \Forms - Applications On Line\2009 Applications \I -2009 - Permit Applicanon.doc Revised: 1 -2009 bh Existing Building Valuation: $ 12- 0 0 .. No If yes, a separate permit and plan submittal will be required. Provide All Building Areas in Square Footage Below PLANNING DIVISION: Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) *For an Accessory dwelling, provide the following: Lot Area (sq ft): "T q- 2. I CO Floor area of principal dwelling: 2- L-P U Floor area of accessory dwelling: *Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard: i S Compact: Handicap: 2- Will there be a change in use? ❑ Yes Er No If "yes ", explain: FIRE PROTECTION/HAZARDOUS MATERIALS: ❑ Sprinklers ❑ Automatic Fire Alarm 111' None ❑ Other (specify) Will there be storage or use of flammable, combustible or hazardous materials in the building? ❑ Yes No If `yes', attach list of materials and storage locations on a separate 8 -1/2 "x 11" paper including quantities and Material Safety Data Sheets. SEPTIC SYSTEM ❑ On -site Septic System - For on -site septic system, provide 2 copies of a current septic design approved by King County Health Department. Page 2 of 6 PERMIT APPLICATION NOTES — Applicable to all permits in this application Value of Construction - In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review - Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. Building and Mechanical Permit The Building Official may grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). Plumbing Permit The Building Official may grant one extension of time for an additional period not exceeding 180 days. The extension shall be requested in writing and justifiable cause demonstrated. Section 103.4.3 Uniform Plumbing Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OR AUTHORIZED AGENT: Signature: ,_� „K. Print Name: �'r74■ 11 t_�f Mailing Address: 112 I S - 1 161 I k Date Application Accepted: Date Application Expires: Staff Initials: H:\Applications\Forms- Applications On Line\2009 Applications \I -2009 - Permit Application.doc Revised: 1 -2009 bh Date: Day Telephone: UICIAI ( LA- City State Zip Page 6 of 6 Parcel No.: 0040000865 Permit Number: D09 -264 Address: 14643 TUKWILA INTERNATIONAL BL TUKW Status: APPROVED Suite No: Applied Date: 12/17/2009 Applicant: JAMAL MARKET Issue Date: Receipt No.: R10 - 00224 Initials: User ID: Payee: WER 1655 SHAHID HAQ • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us TRANSACTION LIST: Type Method Descriptio Amount Payment Check 3497 270.10 Authorization No. ACCOUNT ITEM LIST: Description BUILDING - NONRES STATE BUILDING SURCHARGE Account Code Current Pmts 000.322.100 640.237.114 RECEIPT Total: $270.10 Payment Amount: $270.10 Payment Date: 02/10/2010 10:19 AM Balance: $0.00 265.60 4.50 PAYMENT RECEIVED doc: Receipt -06 Printed: 02 -10 -2010 Receipt No.: R09 - 02013 Initials: User ID: Payee: WER 1655 ACCOUNT ITEM LIST: Description SHAHID UL HAQ PLAN CHECK - NONRES • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Fax: 206 - 431 -3665 Web site: http://www.ci.tukwila.wa.us Payment Check 3484 172.64 Authorization No. TRANSACTION LIST: Type Method Descriptio Amount RECEIPT Parcel No.: 0040000865 Permit Number: D09 -264 Address: 14643 TUICWILA INTERNATIONAL BL TUKW Status: PENDING Suite No: Applied Date: 12/17/2009 Applicant: JAMAL MARKET Issue Date: Payment Amount: $172.64 Account Code Current Pmts 000.345.830 172.64 Total: $172.64 Payment Date: 12/17/2009 11:01 AM Balance: $270.10 PAYMENT ECEIVED doc: Receipt -06 Printed: 12 -17 -2009 Project Type Of Ins' ti : Address: 4(Q45 la--g Date ailed: Spe ial Instructions: • Date Wanted: �] �/ ! i ` � 7 . a.m. Requester: Pone No: INSPECTION O. INSPECTION RECORD Retain a copy with permit 6300 Southcenter Blvd.; #100, Tukwila.- WA 98188 Permit Inspection Request Line (206) 431 -2451 °3°'" PERMIT N0. CITY OF. TUKWILA BUILDING DIVISION I°=' (206) 431 =3670 ri REINSPECTION FEE REQUIR D. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. J Approved per applicable codes. Corrections required prior to approval. COMMENTS: r- r4 er-Arr 0-(1 . A ►. .r ( £k1 rc 4, f � f P55 t-' -o -- r0 0 , e'Sf 'Date: q Project: & MA Type of Inspection: 4 " Address: Da ally it t Sp Date Wanted :. ++''a Fes• Requester: Phone No: Approved per applicable codes. • INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING' DIVISION g 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206)'431 -3 Permit Inspection Request Line (206) 431 -2451 0 0 6 1 orrections required prior to approval. COMMENTS: lam+ , r — Litt re _ttlj G (/\ PrJ a \ -f'1 €trrrr t A p r: Inspeyfor: Date: ❑ REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. COMMENTS: 1.1e4 A-rk A J efAri E 01 OAP \`r Ak t e e."1 rte 4"rc, O ('C�i . c A-0 4- A Aspe 7 � �' - c..T rye( ,'PA A PP `n4 6.0 rree_.7- mot. rejir I)/\ 1,J +4 i' t' 6,-6 d (-0 , ( K r 2_e -:/‘_r pPe P)n - 71 er :s n d_ J Ee I L_t 6.4 KA ^. ce 464ide f4 ar- . � I DA .S % le l M� Jf AJe 2,4" ((e lri r6 Cf..- A t H ) P r . n L L e ,® 8J It J n AO X.: (( A /7 (...,.)‹ t Project: m 41 A „ rex Type of Inspection: Address: I. 5 T 1'r 8, Date all 1...: ' A U, r a .! Specs l Instructions: r C. � JS il. I D�� --� A Or{ ` Sl A `CC d inar fl g-e) -4- l.�ll,) 1 ": 13d5- Date Wanted: ,„�`�` =�Q `IV p.m. equester: Phone No: " inspector k INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 ❑ Approved per applicable codes. INSPECTION RECORD Retain a copy with permit r"1-" 1Date:c_33,,j o r� a� -z dl - PERMIT NO. ` I ` + ' (206)431 -3670 Corrections required prior to approval. $60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. 1 Receipt No.: (Date: r Project:- � A ! A ( M is r Type of Inspection: I I R–Dis le- t . ^ ,-T-Aru(,. Address: 1.4t (43 7 Date Called: Special Instructions: 7 Date Wanted: -----_ - a,p„ 3 -t•v —(J P.m. Requester: Phone N !l �� 234 -28 • Approved per applicable codes. INSPECTION RECORD Retain a copy with permit INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 Ooh -2101 PERMIT NO. .+ (206)431 -3670 Corrections required prior to approval. COMMENTS: Inspector: otU)( Date Iv -t D EJ $60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: Date: COMMENTS: Mme 0l< 0 - –Adr Atk. C -v(. Aft br ( e (- -8 i L e; (.1 - - -i15� < : . r A s p c, :' z1 1 � Date Called: SSA a y - A by /t1' (' 1 v' p 6.(.,Df Specie Instructions: . o-.� .L.� / mac e A L) L on SN,. t i ° J/\ p.m. Requester: Phone No: 1 ZS- 13( -Zki0 Proj AAIA Mme Type of Inspection: , � Address: 11 113 � Date Called: Specie Instructions: . Date Wanted: y - /mom s p.m. Requester: Phone No: 1 ZS- 13( -Zki0 INSPECTION 0. INSPECTION RECORD Retain a copy with permit PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 Approved per applicable codes. Corrections required prior to approval. Inspec or: rr Date: \ _ —, o 17 $60.00 REINSPECTION FEE REQ 1 UIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. (Receipt No.: !Date: COMMENTS: frO I YA. 3 t - P i Ae A It 2_•- a. i aeiss NC • - T~D T1 P i 1- i nee ( P is( aci r—) . (We) A . ) A op e3 f A SLI ' V ) . ' � ;' ef? -P r Y 1 D /. ti 4, -- cLe AeficAK %_S ,A5 4 a Aft P,7 a - Te poST7 ii l; 4-504,o 4,4 s t S r 014 4 'veep- 04 I" pC S`1`t___ A r u , - J jo, 0 13.e,it Le S p e..1. r A sgoo, kz W J n 4-(I %14 "Lcr A Pt B(0 , Pr „ i e m A L. l i t o r i `a d` Type o I c , Address: 43 Date Called: Special Instructions: Date Wanted: — pm. Requester: Pho7 t 3 co r' C) 1�3 ID Approved per applicable codes. Doc- INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 orrections required prior to approval. n $60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Insp ctor: }Date3, Receipt No.: 'Date: COMMENTS: , A �N Type of fspect1-rt: � D i Address: r 144 e . 11L e ::t. .CU OF / - c 1 - J/k E ` e(Cr IA .. �.0Qat M r 5 4 , A 8 b tr. e . to £TP Requester: Phone No: -4 TS (e - 2_i(10 Proje AA ( , A �N Type of fspect1-rt: � D i Address: r 144 e �S ( Date Called: Special Instructions: Date Wanted: ,�a mom�. Z _ 2,4 _ 4 0 Lr�:%� Requester: Phone No: -4 TS (e - 2_i(10 INSPECTION RECORD n Z Retain a copy with permit PERMIT NO. INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 Approved per applicable codes. Inspec!or: 0 Corrections required prior to approval. 1 0ate 11 4 - / O ❑ $60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. 'Receipt No.: 'Date: r COMMENTS: (R'i'ip Of AI- C©L ✓SAS ikRA- �ro ik0 - it � ir 6LP, gir LJ ?_ - j' 5% ,>C 2.-4F/v1 DF p A tt---.-vj Y •:. 0 tr r roa'f-1,-t 1 - mat 0 o ur (414( 6A- (-i r ,i, a l er F T', kl ; Nr ec:{ � `ru -e.r`F� boar _ I ^ A1 I �n ` c1 I I Pro' 4090•4 / i�4.� Type of Inspection: oi• /h/ G Ad: : dr f�6'TJ Date Called: Special Instructions: 2_ ?S/9 g. del 14S e.. vd Date Wante : a? .23//0 �a. R equester: Mfg. 23 G - 26'/7) #k INSPECTION NO. CITY OF TUKWILA BUILDIIsi'G DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 Approved per applicable codes. Receipt No.: INSPECTION RECORD Retain a copy with permit Date: v PERMIT NO. (206)431 -3670 Corrections required prior to approval. • ector: ❑ $60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Syite 100. Call to schedule reinspection. Ins Date: rj Project: �+a �� Type of Inspection: Ate,„ r, j AA, ,, 7v A Address: /9916, Suite #: .. Contact Person: rpoto4 Tagil I..-- Special Instructions: Phone No.: 7 Needs Shift Inspection: Sprinklers: /' Fire Alarm: Hood & Duct: Monitor: Pre -Fire: Permits: Occupancy Type: D INSPECTION NUMBER INSPECTION RECORD Retain a copy with permit CITY OF TUKWILA FIRE DEPARTMENT 444 Andover Park East, Tukwila, Wa. 98188 206- 575 -4407 Inspector: Approved per applicable codes. Word /Inspection Record Form.Doc 1/13/06 •t PERMIT NUMBERS Corrections required prior to approval. COMMENTS: (0),r Q a.n % 3A Scel02 �9//;`0 Hrs.: 0 n $80.00 REINSPE ON FEE REQUIRED. You will receive an invoice from the City of Tukwila Finance Department. Call to schedule a reinspection. T.F.D. Form F.P. 113 COMMENTS: ' Type of Inspection: P V C • c tr t Hood & Duct: d Address: / L i �,4 5— -r-r r SUM #:. Contact Person: S'MA.,LI r r ct E1L- c04: 1 .eI) . 3 Special Instructions: Phone No.: C te -42 1 extirnr hei-) - tctIbb - 00. re d - d - + - - ;Cc reii::.` Kean ic...+ boott2 C' u.v.r.G.A -( hOK luo 1.0c -le.; .w, h i—c ► - • s Project: rJ Type of Inspection: P V C • c tr t Hood & Duct: SA-14,14A_ MiAl-e- Address: / L i �,4 5— -r-r r SUM #:. Contact Person: S'MA.,LI r r ct 1 Special Instructions: Phone No.: Needs Shift Ins pection: Sprinklers: Fire Alarm: , Hood & Duct: Monitor: Pre -Fire: Permits: Occupancy Type: ri per applicable codes. Wont /Inspection Record Form.Doc 1/13/06 INSPECTION RECORD Retain a copy with permit CITY OF TUKWILA FIRE DEPARTMENT INSPECTION NUMBER . . • PERMIT NUMBERS 444 Andover Park East, Tukwila, Wa. 98188 206- 575 -4407 orrections required prior to approval. Inspector: Date: 4 - Hrs.: $80.00 REINSPECTION FEE REQUIRED. You will receive an invoice from the City of Tukwila Finance Department. Call to schedule a reinspection. T.F.D. Form F.P. 113 COMMENTS: /1Dt2(4, Type of Inspection: / 1 `r-e - P P146 Address: I le 6 ci Suite #: • TT 3 Contact Person. S WA Fit T) r c Special Instructions: • Phone No.: o 04.- 9 L- 4t j Permits: Occu pancyType: 1Nt 8- / L - , J I . . O. 4> VVV , Q.-- y ou k4 t. - 4 ) ,r eiVCr - 'I V 1{. • ... 6 . 1 ' - ......_ . - -- -•- . iV S 7 0-1 A.A 4n6- 8*.... to pie RCt -., ic, 4 Project: aevriA.At. /1Dt2(4, Type of Inspection: / 1 `r-e - P P146 Address: I le 6 ci Suite #: • TT 3 Contact Person. S WA Fit T) r c Special Instructions: • Phone No.: o 04.- 9 L- 4t j Needs Shift Inspection: Sprinklers: Are Alarm: Hood & Duct: Monitor: • Pre -Fire: Permits: Occu pancyType: INSPECTION NUMBER INSPECTION RECORD Retain a copy with permit CITY OF TUKWILA FIRE DEPARTMENT PERMIT NUMBERS 444 Andover Park East, Tukwila, Wa. 98188 206 -575 -4407 Approved per applicable codes. CEJC2rrections required prior to approval. Date: , 6 //v Hrs.: t $80.00 REINSPECTION FEE REQUIRED. You will receive an invoice from •the City of Tukwila Finance Department. Call to schedule a reinspection. Word/Inspection Record Forrn.Doc 1/13/06 T.F.D. Form F.P. 113 COMMENTS: /Sprinklers: T e of In ection: ` r t ' N+4 Z--- Address: )4( 3 --rig \ Suite #: ', • Contact Person: S/ p, Ft 1 c HA q Special Instructions: ..., . 1 1 / Co I vy 10.4-e. C" N ' : i r d! S —Co l )1 t "J 6../ ' ' Lo _4(_ s a7 ?" ' /# 4 W; .y a k tw i ts A 0Apt) G A --, A 1 S JJ /] ! 1 f Cali? C C - -- 4144 ^z► or+l - - _I C k,('' -; 4.1 T.. 5 tellT-_P ft 0 i f ! f Yt ti. i - c , r t C: a! 4epL 1/815 S /V 4 .: �...._._, , 1 Ya41 t % l IA) r l 3 1 1 4. ; Project: Z3 L m�kJ- /Sprinklers: T e of In ection: ` r t ' N+4 Z--- Address: )4( 3 --rig \ Suite #: ', Monitor: - Contact Person: S/ p, Ft 1 c HA q Special Instructions: ..., . 1 1 Phone No.: Dot - St a..- 6/oo Needs Shift Inspection: /Sprinklers: Are Alarm: Hood & Duct: Monitor: - Pre -Fire: Permits: i Occupancy Type: INSPECTION NUMBER CITY OF TUKWILA FIRE DEPARTMENT 444 Andover Park. East, Tukwila. Wa. 98188 - 206 - 575 -4407 Approved per applicable codes. INSPECTION RECQRD Retain a copy with permit PERMIT NUMBERS (Corrections required prior to approval. Ins pector: Date: c , p /n • Firs.. $80.00 REINSPECTION FEE REQUIRED. You will receive an invoice from ity of Tukwila Finance Department. Call to schedule a reinspection. Word/Inspection Record Form.Doc 1/13/06 T.F.D. Form F.P. 113 Project: t! / �AM�( / e y Type of Inspection: F /V 14 L Address: )> ,/� 7 3 Suite*: J ` 7 Monitor: 1 Contaerson: 1 Special Instructions: • Occupancy Type: Phone No.: $ g2c r.- G C? b Needs Shift Inspection: Sprinklers: Fire Alarm: Hood & Duct: Monitor: Pre -Fire: Permits: i • • Occupancy Type: sr. • INSPECTION NUMBER INSPECTION RECORD Retain a copy with permit nog- 0 .69. PERMIT NUMBERS 5 f CITY OF TUKWILA FIRE DEPARTMENT 444 Andover Park East, Tukwila, Wa. 98188' 206- 5754407 Approved per applicable codes. Word /Inspection Record Form.Doc 1/13/06 ri Corrections required prior to approval. COMMENTS: s_+ roe 1-4bt 4) k At -i i '.kr Cn..PrQ ( fr 7 t k Inspector: cri 0- Date: 1/9,0/0 v Hrs.: V $80.00 REINSPECTION FEE REQUIRED. You will receive an invoice from t e i ty of Tukwila Finance Department. Call to schedule a reinspection. T.F.D. Form F.P. 113_ Project: ]2 Iv\iNt..... 1A Ar Type of Ins action: '' itnet L Address: Suite #: 1 - ( '- 3 ` , I ,g , t Person: Contac Person Monitor: Special Instructions: Pre -Fire: Phone No.: b, Needs Shift Inspection: Sprinklers'. Fire Alarm: Hood & Duct: ` Monitor: ' -- Pre -Fire: Permits: Occupancy Type: ,r INSPECTION NUMBER • .. INSPECTION RECORD Retain a copy with permit CITY OF TUKWILA FIRE DEPARTMENT 444 Andover Park East, Tukwila, Wa. 98188 206 -575 -4407 Approved per applicable codes. Word /Inspection Record Form.Doc 1/13/06 PERMIT NUMBERS s iA Corrections required prior to approval. COMMENTS: 15, )(0,1 - 7 Lof ZIi 7.2 t CO fr,/lpi C IA Ck 23 ( z9 1 _2_,5 2_(0 ' . , . ,_ f ..sue 4.bv, , . %) e dc-v. ci `l b 1 l l3 aro Inspector 5 Date: zl tz Hrs.: 1 45 $80:00 REINSPECTION FEE REQUIRED: You will an invoice from he City of Tukwila Finance Department. Call to schedule a reinspection. T.F.D. Forrn F.P. 113 Ali Amin, P.E. Consulting Engineer 5400 Carillon Point, 4th floor Kirkland, WA 98033 Ph: (425) 463 -7961 Fax: (206) 973 -5332 email: aamin.engineering @gmail.com Project: Description: bOct 24 $•%-t-i f'TAQ - rENE wr a rnI>govt mE,rT Date: VII 0 b-9 Proj No: 0 1 - 3g A Do F .De 5.T Cro c GR r T C /YC. 6EA -1 PRMVMIT GENIE- E FILE COPY bE5;CN o 1= B AtY1 , Pa _......VA pt.. - O P = 1 0 _ lo" S ,,=a" 1.6 OPLZ j ef 80rPR1 = r2 31.0" LIVE Lo Au . as 1 ,-L . f>E AD low : IS Pi( P',F 4o Un;boy Lo . 4• 46oPL NV AMIN REVIEWED FOF CODE COMPLIAN m . APP CAVED FEB 0 2010 . 0'I ' rn 0, Sh N . ION St CityofTjjj1a = s ` 43 sip' � - BUI DING mimic AL l: l 13t UsE' 6, 6 , D F - i . R Co Lu ■ N5 W r r+1 T O B A5'U. A G A- 6 4. 8 -- 164 Po sr eiNv a d 6 12 - 1 621 .54,,w L, i A-IV D po u R 21-00 x 2,,",,, 8" eoNGRE -re 4019T Cr () WI 1 4. # 4 L%.A wAir D�..o .,4' �4 s.... .4 aimuuA Ali Amin, P.E. Consulting Engineer 5400 Carillon Point, 4th floor Kirkland, WA 98033 Ph: (425) 463 -7961 Fax: (206) 973 -5332 email: aamin.engineering @gmail.com Project: Description: bOct 24 $•%-t-i f'TAQ - rENE wr a rnI>govt mE,rT Date: VII 0 b-9 Proj No: 0 1 - 3g A Do F .De 5.T Cro c GR r T C /YC. 6EA -1 PRMVMIT GENIE- E All Amin, PE (425) 463 -7961 BeamChek v2007 licensed to:. Reg # 201 -175 TI Tukwila store - Shahed roof beam Selection Conditions Data Attributes Actual Critical Status Ratio Values Adjustments Loads 5 -1 /8x 10 -1/2 GLB 24F -V4 DF /DF Lu = 0.0 Ft NOS 2001 Min Bearing Area R1= 3.7 in R2= 3.7 in (1.5) DL Defl= 0.24 in Recom Camber= 0.37 in Beam Span 11.0 ft Beam Wt per ft 0 # Reaction 1 TL 2420 # Reaction 2 TL 2420 # Bm Wt Included 0 # Maximum V 2420 # Max Moment 6655'# Max V (Reduced) 2035 # TL Max Defl L / 360 TL Actual Defl L / 541 Section (in') Shear (in TL Defl (in) 94.17 53.81 0.24 33.28 12.72 0.37 OK OK OK 35% 24% 67% Fb (psi) Fv (psi) E (psi x mil) Fc I (psi) Reference Values 2400 240 1.8 650 Adjusted Values 2400 240 1.8 650 Cv Volume Cd Duration Cr Repetitive Ch Shear Stress Cm Wet Use 1.000 1.00 1.00 1.00 1.00 N/A 1.00 1.00 1.00 CI Stability 1.0000 Rb = 0.00 Le = 0.00 Ft Kbe = 0.0 Uniform Load A Uniform TL: 440 = A Date: 12/15/09 R1 = 2420 R2 = 2420 SPAN = 11 FT Uniform and partial uniform loads are lbs per lineal ft. Public Health Seattle & King Coun �1 • 2010 APPLICATION TO OPERATE A PERMANENT FOOD SERVICE ESTABLISHMENT BUSINESS NAME AND ADDRESS jrA-W � L IVA R2wc l y 6y S- I� 1 N G 2NAci t o t f 10 •V\I{LA v - I \6g Email ADDRESS S nu� C • CoN1 MAILING ADDRESS (if different from above) PLEASE RETURN COMPLETED FORM WITH PAYMENT TO: Public Health - Seattle & King County Downtown Environmental Health 401 - S` Avenue, Suite 1100E Seattle, WA 98104 Name of owner: g \ -t-k -■ 1'v') 14 L {{ Address of owner: O MasterCard O Discover Lig Soom Or F r • City and Zip code: I u k I i -A-W/t 1 (9 . ytime phone number: t,2o( IS 2 6 1 0 0 OFFICE USE ONLY TOTAL FEE DUE PERMIT YEAR IS APRIL 1 THROUGH MARCH 31ST REQUIRED INFORMATION: Does your establishment qualify as a chain? Yes Required 2008 Food Code Changes can be found at: www. kingcounty.gov/health/healthyeating/ A "chain food establishment" is one of at least 15 establishments doing business under the same name, collectively having at least $1 million in gross annual sales and offering substantially the same menu items (80% or more) by number, and at least 15 locations nationwide, regardless if under the same ownership or type of ownership. If a general food service facility, indicate current seating capacity 0 are potentially hazardous foods served? Yes N Is time as temperature control used? Yes _ No Is a Jtighly susceptible population served? Yes No jr If seasonal, list dates of operation: Opening WA Closing N /A•- If grocery store, number of check -out stands Z If you changed facility name, previous name: 10ormation O Check or Money Order PAYABLE TO: SKCDPH 0 Amount Charged: $ . Print Name on Credit Card: O VISA Card Billing Address & ZIP CARD NUMBER CARD EXPIRES / Refit reriipEst o pred card) LTR# PERMIT RECORD ID (PR #) FACILITY NUMBER (FM) C t )' OWNER NUMBER (OW #) PROGRAM ELEMENT (PEP) PLAN REVIEW -SR (SR #) _ VARIANCE -SR (SR #) CHECK NUMBER 31' APPROVED ❑ SIGNED DATE FEE SCHEDULE (See reverse side of this form) PRORATION FEES Operating 4 or fewer months- 25% of fee Operating more than 4 and up to 7 months- 50% of fee Operating more than 7 and up to 10 months- 75% of fee Operating more than 10 and up to 12 months- 100% of fee . $ e - LA. PL,e,v, P ear e.i Permit Infor ❑ Permit Ren O New Opera ❑ Change of R Ownership 1 Classificatio DATE 1 -- Z p 1 0 3 Digit Code (on back): Date No DISAPPROVED ❑ ECEOVE JAN 29 2010 TOWN ENV1ROMENTAt HEALTH TOF PUBLIC ~IEALT IMPORTANT MESSAGE TO APPLICANT: Failure to fully complete form may result in it being returned for completion. Your signature to this form attests to the accuracy of the information and that the food code will be complied with. Renewal applications are mailed each year in February. This office should be notified of any change in your mailing address. If you do not receive a renewal application by February 28 please notify this office at the phone number listed on the back of this form. Late fees are charged if permits are not renewed prior to expiration. SIGNED Payment Cash (In- person only. Do not mail cash) -- _RECEIVED JAN 29 2010 PERMIT CENTER tO ' 1 2 4 9 January 6, 2010 Giri Devarajo 4815 S 146 St Tukwila, WA 98168 Bill Rambo Permit Technician encl File No. D09 -264 W:\Perrnit Center \Correction Letters\2009\D09 -264 Correction Letter #1.DOC • • RE: CORRECTION LETTER #1 Development Permit Application Number D09 -264 Jamal Market —14643 Tukwila International BI Jim Haggerton, Mayor Department of Community Development Jack Pace, Director Dear Mr. Devarajo, This letter is to inform you of corrections that must be addressed before your development permit(s) can be approved. All correction requests from each department must be addressed at the same time and reflected on your drawings. I have enclosed comments from the Building Department. At this time the Fire, Planning, and Public Works Departments have no comments. Building Department: Allen Johannessen at 206 433 -1763 if you have questions regarding the attached memo. Please address the attached comments in an itemized format with applicable revised plans, specifications, and /or other documentation. The City requires that four (4) sets of revised plans, specifications and /or other documentation be resubmitted with the appropriate revision block. In order to better expedite your resubmittal, a `Revision Submittal Sheet' must accompany every resubmittal. I have enclosed one for your convenience. Corrections /revisions must be made in person and will not be accepted through the mail or by a messenger service. If you have any questions, please contact me at (206) 431 -3670. Sincerely, 6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 o Phone: 206 - 431 -3670 0 Fax: 206 - 431 -3665 Building Division Review Memo • Date: January 6, 2010 Project Name: Jamal Market Permit #: D09 -264 Plan Review: Allen Johannessen, Plans Examiner Tukwila Buildi I g Division Allen Johannessen, Plan Examiner The Building Division conducted a plan review on the subject permit application. Please address the following comments in an itemized format with revised plans, specifications and/or other applicable documentation. (GENERAL NOTE) PLAN SUBMITTALS: (Min. size 11x17 to maximum size of 24x36; all sheets shall be the same size). (If applicable) Structural Drawings and structural calculations sheets shall be original signed wet stamped, not copied.) 1. The plans show a saw and sink which appears to be a prep area for the processing of meat products behind the display case. A King County Public Health permit shall be required prior to issuing this permit. Please provide an approved King County Health permit. 2. The plan shows a beam with posts installed. Show a concrete footing and post at the North end of the beam where the beam ends at the North wall. Should there be questions concerning the above requirements, contact the Building Division at 206 -431- 3670. No further comments at this time. December 27th, 2009 City of Tukwila Attn: Dave Larson RE: Tenant Improvement for Jamal Market Determination of completeness Memo dated December 24 2009 Permit no.D09/264 Mr. Dave Larson, Following is the response to your correction letter dated 12- 22 -09. 1) Per our phone conversation yesterday the 28 we proposed to remove one non Load bearing wall and part of bearing wall. These walls have sheet rock that does not extend all way up to roof, so these walls do not resist any lateral load. By removing these walls we are not altering the lateral resisting system. 2) Added foundation sheet no. A2.1 which shows the footing locations and connection details for the beam and column. 3) Same as above Please do not hesitate to call me at 425 -463 -7961 or email me at aamin.engineering(amail.com if I could be of any further assistance. Sincerely; Ali Amin, P.E. I EXPIRES 5/24/ f„efti • Ali Amin, P.E. Structural Engineer 16304 81st PI NE Kenmore, WA 98028 Ph: (425) 463 -7961 INCOMPLETE LTR # .J� bo 21p9 • RECEIVED DEC 30 PERMIT CENTS!- December 22, 2009 Giri Devarajo 4815 S 146 St Tukwila, WA 98168 RE: Letter of Incomplete Application # 1 Development Permit Application D09 -264 Jamal Market — 14643 Tukwila International BI Dear Mr. Devarajo, Bill Rambo Permit Technician Enclosures File: D09 -264 • it 1✓ "t, '� _ 2 ,Y fir' _� CY a W:\Permit Center \Incomplete Letters\2009\D09 -264 Incomplete Ltr # 1.DOC wer Department of Community Development Jack Pace, Director This letter is to inform you that your permit application received at the City of Tukwila Permit Center on December 17, is determined to be incomplete. Before your application can continue the plan review process the following items from the following department need to be addressed: Building Department: Dave Larson at 206 431 -3678 if you have any questions concerning the attached comments. Please address the comment above in an itemized format with applicable revised plans, specifications, and /or other documentation. The City requires that four (4) sets of revised plans, specifications and /or other documentation be resubmitted with the appropriate revision block. In order to better expedite your resubmittal a `Revision Submittal Sheet' must accompany every resubmittal. I have enclosed one for your convenience. Revisions must be made in person and will not be accepted through the mail or by a messenger service. If you have any questions, please contact me at the Permit Center at (206) 431 -3670. Jim Haggerton, Mayor 6300 Southcenter Boulevard, Suite #100 a Tukwila, Washington 98188 0 Phone: 206 - 431 -3670 o Fax: 206 - 431 -3665 Determination of Completeness Memo Date: December 22, 2009 Project Name: Jamal Market Permit #: D09 -264 Plan Review: Dave Larson, Senior Plans Examiner Tukwila Building Division Dave Larson, Sen Plan Examiner The Building Division has deemed the subject permit application incomplete. To assist the applicant in expediting the Department plan review process, please forward the following comments. (GENERAL NOTE) PLAN SUBMITTALS: (Min. size 11x17 to maximum size of 24x36; all sheets shall be the same size). (If applicable) Structural Drawings and structural calculations sheets shall be original signed wet stamped, not copied.) 1. The interior bearing and non - bearing walls to be removed may be resisting lateral loads. Please provide a lateral load analysis to justify the removal of these walls. If additional lateral resisting elements are added to replace the removed walls, please add details to plans. 2. Please provide a foundation plan to show location of new 2 X 2 footings mentioned in the structural calcs. 3. The plans need to include specific connection details and hardware such as post to beam, post to footing and beam to existing roof. Should there be questions concerning the above requirements, contact the Building Division at 206 - 431 -3670. No further comments at this time. DEPARTMENTS: L Building Division Public Works ❑ TUES/THURS ROUTING: Please Route Documents /routing slip.doc 2 -28 -02 • PLAN REVI REVIEWER'S INITIALS: ACTIVITY NUMBER: D09 -264 DATE: 01 -29 -10 PROJECT NAME: JAMAL MARKET SITE ADDRESS: 14643 TUKWILA INTERNATIONAL BL Original Plan Submittal Response to Incomplete Letter # X Response to Correction Letter # 1 Revision # After Permit Issued Fire Prevention Structural DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete Incomplete ❑ Not Applicable ❑ Comments: Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: Structural Review Required APPROVALS OR CORRECTIONS: Approved n Approved with Conditions Notation: REVIEWER'S INITIALS: TING SLIP ❑ Permit Coordinator DUE DATE: 02 -02 -10 ❑ No further Review Required DATE: DUE DATE: 03 -02 -10 DATE: Planning Division Not Approved (attach comments) ❑ Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: • • PLAN R IE /ROUTING SLIP ACTIVITY NUMBER: D09 -264 DATE: 12 -30 -09 PROJECT NAME: JAMAL MARKET SITE ADDRESS: 14643 TUKWILA INTERNATIONAL BL Original Plan Submittal X Response to Incomplete Letter # 1 Response to Correction Letter # Revision # After Permit Issued DEPAR MENTS: uilding ivision Public Works Complete Structural DETERMINATION OF COMPLETENESS: (Tues., Thurs.) DUE DATE: 12-31-09 Incomplete Comments: Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: TUES /THURS ROUTING: Please Route y"' Structural Review Required REVIEWER'S INITIALS: APPROVALS OR CORRECTIONS: Documents /routing slip.doc 2 -28 -02 m� r, 12 'l ire Prevention u n ❑ Permit Coordinator No further Review Required DATE: Planning Division Not Applicable n DUE DATE: 01 -28-10 n Approved n Approved with Conditions ^ Not Approved (attach comments) Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only to -1 LETTER MAILED: I ' to I Departments issued corrections: Bldg Fire ❑ Ping ❑ PW ❑ Staff Initials: by( b DEPARTMENTS: ecb U q Building Division ti Ili --061 blic W k Complete TUES /THURS ROUTING: Please Route Documents /routing slip.doc 2 -28 -02 • • OE I PLAN REVIEW /ROUTING SLIP n ACTIVITY NUMBER: D09 -264 DATE: 12 -17 -09 PROJECT NAME: JAMAL MARKET SITE ADDRESS: 14643 TUKWILA INTERNATIONAL BL X Original Plan Submittal Response to Incomplete Letter # Response to Correction Letter # Revision # After Permit Issued Fire Prevention Structural DETERMINATION OF COMPLETENESS: (Tues., Thurs.) DUE DATE: 12 -22 -09 Incomplete Comments: Permit Center Use Only INCOMPLETE LETTER MAILED: 1. LETTER OF COMPLETENESS M9ILED: Departments determined incomplete: Bldg- Fire ❑ Ping ❑ PW ❑ Staff Initials: Structural Review Required APPROVALS OR CORRECTIONS: Approved I I Approved with Conditions sri Planning Division Permit Coordinator Not Applicable No further Review Required REVIEWER'S INITIALS: DATE: DUE DATE: 01 -19 -10 Notation: REVIEWER'S INITIALS: DATE: Not Approved (attach comments) n Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: REVISION SUBMITTAL i Revision submittals must be submitted in person at the Permit Center. Revisions will not be accepted through the mail, fax, etc. Date: City of Tukwila ❑ Response to Incomplete Letter # Response to Correction Letter # ❑ Revision # after Permit is Issued ❑ Revision requested by a City Building Inspector or Plans Examiner Project Name: 3m(- YYl frR ? E T Project Address: V 14-6 - ` k � U( .1 ✓1i J B1 Z Contact Person: 1' Phone Number: c2O9 ' S 2. IC I CO Summary of Revision: Sheet Number(s): "Cloud" or highlight all areas of revision including date of revision Received at the City of Tukwila Permit Center by: / -� r"a- Entered in Permits Plus on \applications \forms- applications on Tine \revision submittal Created: 8 -13 -2004 Revised: 1 -2009 • • Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206- 431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us Plan Check/Permit Number: P 0R - 264_ apt ...0 UPli PERMIT GEN -1'ER • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us Revision submittals must be submitted in person at the Permit Center. Revisions will not be accepted through the mail, fax, etc. Date: 12 . 3 0 • O Plan Check/Permit Number: D09 -264 ® Response to Incomplete Letter # 1 ❑ Response to Correction Letter # ❑ Revision # after Permit is Issued ❑ Revision requested by a City Building Inspector or Plans Examiner Project Name: Jamal Market Project Address: 14643 Tukwila International BI Contact Person: \applications \forms - applications on line\revision submittal Created: 8 -13 -2004 Revised: Steven M. Mullet, Mayor Steve Lancaster, Director a 1 g i vsRbone Number: LOA 7 r. 16 28 1 Q Summary of Revision: C- N CITY OF TUKWIIA DEC 0 2009 • Sheet Number(s): "Cloud" or highlight all areas of revision including date of revision Received at the City of Tukwila Permit Center by: J" Entered in Permits Plus on CITY OF TUKWILA Department of Community Development 6300 Southcenter Boulevard, Tukwila, WA 98188 Telephone: (206) 431 -367o FAX (206) 431 -3665 E - mail: tukplanCa ci.tukwila.wa.us AFFIDAVIT IN LIEU OF CONTRACTOR REGISTRATION STATE OF WASHINGTON) ) ss. COUNTY OF KING ) l9 A-18 [please print name] , states as follows: 1. I have made application for a permit from the City of Tukwila, Washington. 2. I understand that state law requires that all building construction contractors be registered with the State of Washington. The exceptions to this requirement are stated under Section 18.27.090 of the Revised Code of Washington, a copy of which is printed on the reverse side of this Affidavit. I have read or am familiar with RCW 18.27.090. 3. I understand that prior to issuance of a permit for work which is to be done by any contractor, the City of Tukwila must verify either that the contractor is registered by the State of Washington, or that one of the exemptions stated under RCW 18.27.090 applies. 4. In order to provide verification to the City of Tukwila of my compliance with this requirement, I hereby attest that after reading the exemptions from the registration requirement of RCW 18.27.090, I consider the work authorized under this permit to be exempt under number . and will therefore not be performed by a registered contractor. 5. I understand that the licensing provision of RCW 19.28.161 through 19.28.271 shall not apply to persons making electrical installations on their own property or to regularly employed employees working on the premises of their employer. The proposed electrical work is not for the construction of a new building for rent, sale or lease. I understand that I may be waiving certain rights that I might otherwise have under state law in any decision to engage an unregistered contractor to perform construction work. Owner /Owner's Agent* Signed and sworn to before me this N .∎\‘\\ \11111 A. 1 1 1 i SJg10N F A,�'l =:k ° AI p � i U _ _ (n i , % I o day of C , 20 1 n 'si up w ow - I PERMIT NO: '0 2 - ( e 1 �ctie. Gj l� �( N ;r - ` PUBLIC in and for the State of Washington Residing at kloo/ Name as commissioned: My commission expires: Permit Center /Building Division 206 431 -3670 Public Works Department 206 433 - 0179 Planning Division 206 431 -3670 , County / p5 - -1 18.27.090 Exemptions. The registration provisions of this 1. An authorized representative of the United States government, the state of Washington, or any incorporated city, town, county, township, irrigation district, reclamation district, or other municipal or political corporation or subdivision of this state; 2. Officers of a court when they are acting within the scope of their office; 3. Public utilities operating under the regulations of the utilities and transportation commission in construction, maintenance, or development work incidental to their own business; 4. Any construction, repair, or operation incidental to the discovering or producing of petroleum or gas, or the drilling, testing, abandoning, or other operation of any petroleum or gas well or any surface or underground mine or mineral deposit when performed by an owner or lessee; 5. The sale of any finished products, materials, or articles of merchandise that are not fabricated into and do not become a part of a structure under the common law of fixtures; 6. Any construction, alteration, improvement, or repair of personal property performed by the registered or legal owner, or by a mobile /manufactured home retail dealer or manufacturer licensed under chapter 46.70 RCW who shall warranty service and repairs under chapter 46.70 RCW; 7. Any construction, alteration, improvement, or repair carried on within the limits and boundaries of any site or reservation under the legal jurisdiction of the federal government; 8. Any person who only furnished materials, supplies, or equipment without fabricating them into, or consuming them in the performance of, the work of the contractor; 9. Any work or operation on one undertaking or project by one or more contracts, the aggregate contract price of which for labor and materials and all other items is less than five hundred dollars, such work or operations being considered as of a casual, minor, or inconsequential nature. The exemption prescribed in this subsection does not apply in any instance wherein the work or construction is only a part of a larger or major operation, whether undertaken by the same or a different contractor, or in which a division of the operation is made into contracts of amounts less than five hundred dollars for the purpose of evasion of this chapter or otherwise. The exemption prescribed in this subsection does not apply to a person who advertises or puts out any sign or card or other device which might indicate to the public that he or she is a contractor, or that he or she is qualified to engage in the business of contractor; 10. Any construction or operation incidental to the construction and repair of irrigation and drainage ditches of regularly constituted irrigation districts or reclamation districts; or to farming, dairying, agriculture, viticulture, horticulture, or stock or poultry raising; or to clearing or other work upon land in rural districts for fire prevention purposes; except when any of the above work is performed 0 chapter do not apply to: by a registered contractor; ii. An owner* who contracts for a project with a registered contractor, except that this exemption shall not deprive the owner of the protections of this chapter against registered and unregistered contractors. The exemption prescribed in this subsection does not apply to a person who performs the activities of a contractor for the purpose of leasing or selling improved property he or she has owned for less than twelve months; 12. Any person working on his or her own property, whether occupied by him or her or not, and any person working on his or her personal residence, whether owned by him or her or not but this exemption shall not apply to any person who performs the activities of a contractor on his or her own property for the purpose of selling, demolishing, or leasing the property; 13. An owner* who performs maintenance, repair, and alteration work in or upon his or her own properties, or who uses his or her own employees to do such work; 14. A licensed architect or civil or professional engineer acting solely in his or her professional capacity, an electrician certified under the laws of the state of Washington, or a plumber certified under the laws of the state of Washington or licensed by a political subdivision of the state of Washington while operating within the boundaries of such political subdivision. The exemption provided in this subsection is applicable only when the person certified is operating within the scope of his or her certification; 15. Any person who engages in the activities herein regulated as an employee of a registered contractor with wages as his or her sole compensation or as an employee with wages as his or her sole compensation; 16. Contractors on highway projects who have been prequalified as required by RCW 47.28.070, with the department of transportation to perform highway construction, reconstruction, or maintenance work; 17. A mobile /manufactured home dealer or manufacturer who subcontracts the installation, set -up, or repair work to actively registered contractors. This exemption only applies to the installation, set -up, or repair of the mobile /manufactured homes that were manufactured or sold by the mobile /manufactured home dealer or manufacturer; 18. An entity who holds a valid electrical contractor's license under chapter 19.28 RCW that employs a certified journeyman electrician, a certified residential specialty electrician, or an electrical trainee meeting the requirements of chapter 19.28 RCW to perform plumbing work that is incidentally, directly, and immediately appropriate to the like -in -kind replacement of a household appliance or other small household utilization equipment that requires limited electric power and limited waste and /or water connections. An electrical trainee must be supervised by a certified electrician while performing plumbing work. • Per Washington State Department of Labor and Industries, lessee has been interpreted to be equivalent to owner for the purpose of these exemptions. Pio changes sha REVISIONS ft be made to the scope of work without prior approval of Tukwila Building Division. NOT: revisions will require a new plan submitt?I r : r.•6:fvon= EB , SITE PLAN NiTs Perm Plan review approval Is to ens and mist= hpproval of constniction documents doss not authorize the violation of any adopted outs or odnanos. Receipt of approved Field Copy and cations is acknovAedoed: D 0 • city 0? ligievIIIE PARKING FciAIILDING DIVISION BUILD ING IN LOT AND IN FRONT OF T1-4E STORE TENANT IMPROVEMENT SHOUJN HATCHED SQ. FOOTAGE: 2445 SQ FT. HEATING: FORCED AIR 1 0- 1)09-- 210J4 FELE MP17 HopaatAkti 4 SEPARATE PERMIT REQUIRED FOR: artlechanicel allectrical U mb s kts PIPM1 RECEIVED • DEC 17 2009 PERMIT CENT& PROIJECT DATA City of Tu Bl DIVIS SITE ADDRESS: 14643 414645 TUKWILA INTERNATIONAL BLVD. PARCEL NO. 0040000565 REVIEWED FOR CODE COMPLIANCE APPROVED FEB O 2010 tA4 City of Tukwila BUILDING DIVISIMI U 0 0 (.4 E a.) — N • 0 DATE: JOB NO: SHEET Al NEW 3068 STOREDOOR LOCATION —\ 3 -0 3 -0 SGD PROJECT DATA ELEC. PANEL 14' -3 REMOVE EXISTING DOOR AND FILL IN WALL LEGEND EXISTING WALLS WALL TO BE REMOVED c NEW WALLS EiMEMEM PARCEL NO. 0040000865 SQ. FOOTAGE: 2445 SQ FT. HEATING: FORCED AIR OCCUPANCY CLASSIFICATION: MERCANTILE GROUP M TYPE OF CONSTRUCTION TYPE V -B � I i 0 (-1 , REMOVE WALL ti- 01/ ID,NEL --_! EXISTING COLUMN CONC. SLAB EL= +4 NEW DOOR LOCATION SITE ADDRESS: 14543 4 14645 TUKWILA INTERNATIONAL BLVD. 5 -I /3x10 1/2 G 4' 5 IN C bIL TANK 1ST FLOOR PLAN SCALE 1/S' =1 -0' CC DUCTING ABOVE PROJECT DESCRIPTION: REMOVE SOME INTERIOR WALLS BOTH NON - BEARING AND BEARING FOR LAYOUT OF SHELVING AND DISPLAY FOR AN INTERNATIONAL GROCERY STORE . THE EXISTING USE WAS A MEXICAN GROCERY STORE BD 3(c 68 h' +1 II II II II 3/S° 5 -I/ NEW 6x6 COLUMN _TaIEW_RAMP 4 ..RISE EP NC. r LAB II 0005 10' -10 3/S° 10' -10 3 /S° CONC. SLAB EL= +0 EXISTING I- 4IGI -I WINDOWS WIDE SIDEWALK\ MOVE EXIST. BRG. WALL 5- 1/8x10 -I/2 GLB� II u C - -- FLOOR PLAN SYMBOL LEGEND 0 ui IL WALL TO BE REMOVED (TYP) ABA66 POST BASE 4 BC5 COLUMN CAP PER ENGINEER (TYP) CEILING MOUNTED SELF - ILLUMINATED EXIT SIGN AS SHOWN PER PLANS WALL MOUNTED SELF - ILLUMINATED EXIT SIGN AS SHOWN PER PLANS FIRE EXTINGUISHER IN CABINET REVIEWED FOR CODE COMPLIANCE APPROVED FEB 0 9 2010 City of Tukwila BUILDING DIVISION EMERGENCY LIGHTING PER CODE, FLUORECSENT FIXTURE, WALL MOUNTED WITH FULL CABINET AND LENSE. PROVIDE (1) FOOTCANDLE MINIMUM ILLUMINATION AT ALL CORRIDORS, STAIRS, EXITS AND OTHER NON - RESIDENTIAL SPACES WITH AUTOMATIC EMERGENCY SYSTEM BACK -UP IN THE EVENT OF POWER FAILURE RECEWVEr DEC 17 2009 PERMIT CENTE J Q <I= w LLS w Ce Z w w 0 IZ F Z z w • • 1- U O DATE: JOB NO: SHEET A2 10' 10 3/8" FOUNDATION PLAN SCALE 1/8° =1' -0° INCOMPLETE LTR# L DD — 2 67 L/ ED SAW CUT 4 POUR 2 '- 0'x2 -0'x8' CONC. FTG. W/ (4) *4 REBAR EACH WAY p-- �ABA66 POS BASE 4 BCe POST CAP TYPICAL 10' -10 3/5" 10'-10 3/8" EXISTING 2x6 RAFTERS see slavE 4 REVIEWED FOR CODE COMPLIANCE APPROVED FEB 0 9 2010 City of Tukwila BUILDING DIVISION 1-125 TO EACH RAFTER 5- 1/8x10 -1/2 GLB C6 COLUMN CAP WITH (12) 16d NAILS z--- ABA66 POST BASE 8 -16d NAILS 5/8° DIA. x 6' THREADED ROD RECEIVE X342009 24 FTG w/ PERMIT CENTEr (4) 4 EA. WAY DATE: JOB NO: SHEET [ A2.1 2X4 EXTERIOR WALLS GRADE TORCH DOWN ROOF OVER 2x6 RAFTERS AT 24' O.G. CONC. SLAB ON EXISTING BEARING WALL W/ THICKENED SLAB REMOVED EXISTING BEARING WALL AND INSTALL GLB PER PLAN MASONRY WALL CONSTRUCT ION / r- BUILDING SECTION SCALE 1/4' REVIEWED FOR CODE COMPLIANCE APPROVED FEB 0 9 2010 City of Tukwila BUILDING DIVISIMI RECEWWEP DES 17 2009 PERMIT CENTE -. 0 0 DATE: JOB NO: SHEET A3 SAW D ISPLAY CASE REG MINI CART CART I Ii CHECKOUT IJV 1ST FLOOR PLAN FIXTURE LAYOUT SCALE 1/8' =1 0 4 ' 8 ' SHELVES SHELVES 1s' OD 0 / SHELVES REVIEWED FOR CODE COMPLIANCE APP OVER) FEB 0 2010 City of Tukwila BUILDING DIVISION RECEIVED DEC 172009 PERMIT CENTEI b U 0 E 0 N O R,0;_ ;4 N DATE: JOB NO: SHEET A4 NEW 3068 STOREDOOR SGD LOCATION —\ 3 -0 ELEC. PANEL 14' -3' 3 -0 RE MOVE EXISTING DOOR AND FILL IN WALL LEGEND EXISTING WALLS WALL TO BE REMOVED c NEW WALLS ■ 3 -0 Co 3 - , REMOVE WALL 1 1 i IE_ R�F�oV LD, CL EXISTING COLUMN CONC. SLAB EL= +4 NEW DOOR LOCATION PROIJECT DATA bIL TANK LB 1ST FLOOR PLAN SCALE 1/S°:1'—�° DUCTING ABOVE Do NEW 4x5 COLUMN 3 5 -1 /= GLB SITE ADDRESS: 146.43 4 14645 TUKWILA INTERNATIONAL BLVD. PARCEL NO. 0040000865 SQ. FOOTAGE: 2445 SQ FT. HEATING: FORCED AIR 68 NEW RAMP 1:12 4' RISE CONC. SLAE3 EP : EL= +0 NC. rLAB EXISTING HIGH WINDOWS WIDE SIDEWALKM ZMOVE EXIST. E3RG. WALL STOR. 3/8" 10' -10 3/8° 1 -10 3/8° . 1] U U- 3 -0 C PROVIDE 24'x24'x8' CONC PAD W/ (4) *4 EA. WAY AT (4) LOCATIONS . WALL TO BE REMOVED (TYP) FLOOR PLAN SYMBOL LEGEND ® CEILING MOUNTED SELF - ILLUMINATED EXIT SIGN AS SHOWN PER PLANS WALL MOUNTED SELF - ILLUMINATED ® EXIT SIGN AS SHOWN PER PLANS FIRE EXTINGUISHER IN CABINET CORRECTION LTR #_11_, D09- 2 by REVIEWED FOR CODE COMPLIANCE VED FEB 0 2010 City of Tukwila BUILDING DIVISInM EMERGENCY LIGHTING PER CODE, FLUORECSENT FIXTURE, WALL MOUNTED WITH FULL CABINET AND LENSE. PROVIDE (I) FOOTCANDLE MINIMUM ILLUMINATION AT ALL CORRIDORS, STAIRS, EXITS AND OTHER NON - RESIDENTIAL SPACES WITH AUTOMATIC EMERGENCY SYSTEM BACK -UP IN THE EVENT OF POWER FAILURE RECEIVE r JAN 292010 PERMIT CENTEI REVISION DATE I -19 -I0 CORRECTION PER CITY DATE: JOB NO: SHEET A6