Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Permit D09-269 - CARTERS BABIES AND KIDS - TENANT IMPROVEMENT
CARTERS BABIES & KIDS 17250 SOUTHCENTER PY SUITE 144 D09 -269 Parcel No.: 7888920020 Address: 17250 SOUTHCENTER PY TUKW Suite No: Tenant: Name: CARTERS BABIES AND KIDS Address: 17250 SOUTHCENTER PY, STE 144 , TUKWILA WA Owner: Name: WIG PROPERTIES LLC -SS Address: 4811 134TH PL SE , BELLEVUE WA 98006 Phone: Contact Person: Name: BRYANT DANIEL Address: 225 OAKLAND RD , SOUTH WINDSOR CT 06074 Phone: 860 783 -5670 Contractor: Name: LAKEVIEW CONSTRUCTION INC Address: PO BOX 308 , PLEASANT PRAIRIE, WI 53158 Phone: 414 657 -4222 Contractor License No: LAKEVCI072KC DESCRIPTION OF WORK: SALES AREA: ENTRY MAT, WOOD PLANK FLOORING, BASE, SURFACE MOUNTED STANDARDS, FLOOR FIXTIRES, CEILING - HALIDE TRACK FIXTURES (B1) & SEMI RECESSED WALL WASH FIXTURE (B), SPEAKERS (S). STOCKROOM/OFFICE: SURFACE MOUNTED STANDARDS AND FLOOR FIXTURES. (ELECTRICAL AND MECHANICAL WORK UNDER SEPARATE PERMIT). Value of Construction: $55,000.00 Fees Collected: $1,589.82 Type of Fire Protection: NONE International Building Code Edition: 2006 Type of Construction: UB Occupancy per IBC: 0019 doc: IBC -10/06 City�f Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Inspection Request Line: 206- 431 -2451 Web site: http://www.citukwila.wa.us DEVELOPMENT PERMIT * *continued on next page ** • Permit Number: D09 -269 Issue Date: 01/27/2010 Permit Expires On: 07/26/2010 Expiration Date: 01/13/2011 D09 -269 Printed: 01 -27 -2010 Public Works Activities: Channelization / Striping: N Curb Cut / Access / Sidewalk / CSS: N City oftukwila • Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Inspection Request Line: 206 - 431 -2451 Web site: http: / /www.ci.tukwila.wa.us Permit Number: D09 -269 Issue Date: 01/27/2010 Permit Expires On: 07/26/2010 Fire Loop Hydrant: N Number: 0 Size (Inches): 0 Flood Control Zone: Hauling: N Start Time: End Time: Land Altering: Volumes: Cut 0 c.y. Fill 0 c.y. Landscape Irrigation: Moving Oversize Load: Start Time: End Time: Sanitary Side Sewer: Sewer Main Extension: Private: Public: Storm Drainage: Street Use: Profit: N Non - Profit: N Water Main Extension: Private: Public: Water Meter: Permit Center Authorized Signature: N Date: I hereby certify that I have read and ed this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complie • whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating constru on or the perfo anc .f work. I am authorized to sign and obtain this development permit. Signature: '4MV `--- -- Date: / ) //O Print Name: �C4,. ■ 1 1 -- A-e€ r/ This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. doc: IBC -10/06 D09 -269 Printed: 01 -27 -2010 Parcel No.: 7888920020 Address: Suite No: Tenant: 1: ** *BUILDING DEPARTMENT CONDITIONS * ** • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http://www.ci.tukwila.wa.us 17250 SOUTHCENTER PY TUKW CARTERS BABIES AND KIDS PERMIT CONDITIONS Permit Number: Status: Applied Date: Issue Date: D09 -269 ISSUED 12/22/2009 01/27/2010 2: No changes shall be made to the approved plans unless approved by the design professional in responsible charge and the Building Official. 3: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center (206/431- 3670). 4: All permits, inspection records, and approved plans shall be at the job site and available to the inspectors prior to start of any construction. These documents shall be maintained and made available until final inspection approval is granted. 5: All construction shall be done in conformance with the approved plans and the requirements of the International Building Code or International Residential Code, International Mechanical Code, Washington State Energy Code. 6: There shall be no occupancy of a building until final inspection has been completed and approved by Tukwila building inspector. No exception. 7: A Certificate of Occupancy shall be issued for this building upon final inspection approval by Tukwila building inspector. 8: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the Cityof Tukwila Permit Center. 9: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206- 431 - 3670). 10: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. 11: ** *FIRE DEPARTMENT CONDITIONS * ** 12: The attached set of building plans have been reviewed by the Fire Prevention Bureau and are acceptable with the following concerns: 13: The total number of fire extinguishers required for an ordinary hazard occupancy with Class A fire hazards is calculated at one extinguisher for each 1,500 sq. ft. of area. The extinguisher(s) should be of the "All Purpose" (2A, 20B:C) dry chemical type. Travel distance to any fire extinguisher must be 75' or less. (IFC 906.3) (NFPA 10, 3 -2.1) 14: Portable fire extinguishers, not housed in cabinets, shall be installed on the hangers or brackets supplied. Hangers or brackets shall be securely anchored to the mounting surface in accordance with the manufacturer's installation instructions. Portable fire extinguishers having a gross weight not exceeding 40 pounds (18 kg) shall be installed so that its top is not more than 5 feet (1524 mm) above the floor. Hand -held portable fire extinguishers having a gross doc: Cond -10/06 D09 -269 Printed: 01 -27 -2010 • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http://www.ci.tukwila.wa.us weight exceeding 40 pounds (18 kg) shall be installed so that its top is not more than 3.5 feet (1067 mm) above the floor. The clearance between the floor and the bottom of the installed hand -held extinguishers shall not be less than 4 inches (102 mm). (IFC 906.7 and IFC 906.9) 15: Fire extinguishers shall not be obstructed or obscured from view. In rooms or areas in which visual obstruction cannot be completely avoided, means shall be provided to indicate the locations of the extinguishers. (IFC 906.6) 16: Extinguishers shall be located in conspicuous locations where they will be readily accessible and immediately available for use. These locations shall be along normal paths of travel, unless the fire code official determines that the hazard posed indicates the need for placement away from normal paths of travel. (IFC 906.5) 17: Fire extinguishers require monthly and yearly inspections. They must have a tag or label securely attached that indicates the month and year that the inspection was performed and shall identify the company or person performing the service. Every six years stored pressure extinguishers shall be emptied and subjected to the applicable recharge procedures. If the required monthly and yearly inspections of the fire extinguisher(s) are not accomplished or the inspection tag is not completed, a reputable fire extinguisher service company will be required to conduct these required surveys. (NFPA 10, 4 -3, 4 -4) 18: Egress doors shall be readily openable from the egress side without the use of a key or special knowledge or effort. (IFC 1008.1.8.3 subsection 2.2) 19: Dead bolts are not allowed on auxiliary exit doors unless the dead bolt is automatically retracted when the door handle is engaged from inside the tenant space. (IFC Chapter 10) 20: Door handles, pulls, latches, locks and other operating devices on doors required to be accessible by Chapter 11 of the International Building Code shall not require tight grasping, tight pinching or twisting of the wrist to operate. (IFC 1008.1.8.1) 21: Exit hardware and marking shall meet the requirements of the International Fire Code. (IFC Chapter 10) 22: Exits and exit access doors shall be marked by an approved exit sign readily visible from any direction of egress travel. Access to exits shall be marked by readily visible exit signs in cases where the exit or the path of egress travel is not immediately visible to the occupants. Exit sign placement shall be such that no point in an exit access corridor is more than 100 feet (30,480 mm) or the listed viewing distance for the sign, whichever is less, from the nearest visible exit sign. (IFC 1011.1) 23: Every exit sign and directional exit sign shall have plainly legible letters not less than 6 inches (152 mm) high with the principal strokes of the letters not less than 0.75 inch (19.1 mm) wide. The word "EXIT" shall have letters having a width not less than 2 inches (51 mm) wide except the letter "I ", and the minimum spacing between letters shall not be less than 0.375 inch (9.5 mm). Signs larger than the minimum established in section 1011.5.1 of the International Fire Code shall have letter widths, strokes and spacing in proportion to their height. The word "EXIT" shall be in high contrast with the background and shall be clearly discernible when the exit sign illumination means is or is not energized. If an arrow is provided as part of the exit sign, the construction shall be such that the arrow direction cannot be readily changed. (IFC 1011.5.1) 24: Exit signs shall be illuminated at all times. To ensure continued illumination for a duration of not less than 90 minutes in case of primary power loss, the sign illumination means shall be connected to an emergency power system provided from storage batteries, unit equipment or on -site generator. (IFC 1006.1, 1006.2, 1006.3) 25: Means of egress, including the exit discharge, shall be illuminated at all times the building space served by the means of egress is occupied. The means of egress illumination level shall not be less than 1 foot -candle (11 lux) at the floor level. The power supply for the means of egress illumination shall normally be provided by the premise's electrical supply. In event of a power failure art emergency power system shall provide power for a duration of not less than 90 minutes and shall consist of storage batteries, unit equipment or on -site generator. (IFC 1006.1, 1006.2, 1006.3) The path of egress shall require emergency lighting until exit discharge is accomplished. doc: Cond-10/06 D09 -269 Printed: 01 -27 -2010 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http://www.citukwila.wa.us 26: Aisles leading to required exits shall be provided from all portions of the building and the required width of the aisles shall be unobstructed. (IFC 1013.4) 27: Maintain sprinkler coverage per N.F.P.A. 13. Addition/relocation of walls, closets or partitions may require relocating and/or adding sprinkler heads. (IFC 901.4) 28: Sprinklers shall be installed under fixed obstructions over 4 feet (1.2 m) wide such as ducts, decks, open grate flooring, cutting tables, shelves and overhead doors. (NFPA 13- 8.6.5.3.3) 29: All new sprinkler systems and all modifications to existing sprinkler systems shall have fire department review and approval of drawings prior to installation or modification. New sprinkler systems and all modifications to sprinkler systems involving more than 50 heads shall have the written approval of the W.S.R.B., Factory Mutual, Industrial Risk Insurers Kemper or any other representative designated and /or recognized by the City of Tukwila, prior to submittal to the Tukwila Fire Prevention Bureau. No sprinkler work shall commence without approved drawings. (City Ordinance #2050) 30: A fire alarm system is required for this project. The fire alarm system shall meet the requirements of N.F.P.A. 72 and City Ordinance #2051. 31: Local U.L. central station supervision is required. (City Ordinance #2051) 32: Maintain fire alarm system audible /visual notification. Addition/relocation of walls or partitions may require relocation and/or addition of audible /visual notification devices. (City Ordinance #2051) 33: All new fire alarm systems or modifications to existing systems shall have the written approval of The Tukwila Fire Prevention Bureau. No work shall commence until a fire department permit has been obtained. (City Ordinance #2051) (IFC 104.2) 34: An electrical permit from the City of Tukwila Building Department Permit Center (206- 431 -3670) is required for this project. 35: All electrical work and equipment shall conform strictly to the standards of the National Electrical Code. (NFPA 70) 36: The maximum flame spread class of finish materials used on interior walls and ceilings shall not exceed that set forth in Table No. 803.5 of the International Building Code. 37: In order to provide you with the fastest police and fire protection under emergency conditions, please post your suite, room or apartment number in a conspicuous place near the main entry door. (IFC 505.1) 38: This review limited to speculative tenant space only - special fire permits may be necessary depending on detailed description of intended use. 39: Contact The Tukwila Fire Prevention Bureau to witness all required inspections and tests. (City Ordinances #2050 and #2051) 40: Any overlooked hazardous condition and/or violation of the adopted Fire or Building Codes does not imply approval of such condition or violation. 41: These plans were reviewed by Inspector 511. If you have any questions, please call Tukwila Fire Prevention Bureau at (206)575 -4407. 42: Sheet A 3.1 Signage shown is not approved as part of this permit. A separate sign permit must be acquired prior to any sign installation. 43: Sheet A 6.1 - HVAC system must be sized and located to be screened while viewed from the adjacent sidewalks around the doc: Cond -10/06 D09 -269 Printed: 01 -27 -2010 site's perimeter. doc: Cond -10/06 010 • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us * * continued on next page ** D09 -269 Printed: 01 -27 -2010 I hereby certify that I have read these conditions and will comply with them as outlined. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provision of any other work or local laws regulating construction or the performance of work. Print Name: doc: Cond -10/06 • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http://www.ci.tukwila.wa.us Date: /2 2`/ D09 -269 Printed: 01 -27 -2010 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us CERTIFICATE OF OCCUPANCY This certificate is issued pursuant to the requirements of Section 110.2 of the 2006 edition of the International Building Code. At the time of issuance, this structure or portion thereof has been inspected for compliance with the requirements of this code for the occupancy and division of occupancy and the use for which the proposed occupancy is classified. Building Permit No.: D09 -269 Occupant /Tenant: CARTERS BABIES AND KIDS Building Address: 17250 SOUTHCENTER PY, SUITE NO. 144 Parcel No.: 7888920020 Property Owner: WIG PROPERTIES LLC -SS 4811 134TH PL SE , BELLEVUE WA 98006 Use: RETAIL Occupancy Group /Division: M Type of Construction: IIB Automatic Sprinkler System: Provided: Y Required: Y Design Occupant Load: 112 ( A/P1' . ? BUILDING O FIICIA DATE THIS CERTIFICATE TO BE CONSPICUOUSLY POSTED ON THE PREMISES CITY OF TUKWILA Community Development Department Public Works Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http: // wtw.ci.tukwila. SITE LOCATION King Co Assessor's Tax No.: 14Q 1,2- ^ 0 Oi Site Address: Southcenter Square, 17250 Southcenter Parkway Suite Number: 144 Floor: 1 Carters babies and kids Tenant Name: Property Owners Name: Wig Properties, LLC Mailing Address: 4811 134th PL SE • Building Permit No. Mechanical Permit No. Plumbing/Gas Permit No. Public Works Permit No. Project No. (For office use only) Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. * *Please Print ** Bellevue City New Tenant: m Yes ❑ ..No WA State 98006 Zip CONTACT PERSON — who do we contact when your permit is ready to be issued • • . • Name: Bryant Daniel Mailing Address: 225 Oakland road E -Mail Address: bdaniel @cadd - tech.com • GENERAL CONTRACTOR INFORMATION, - (Contractor Info for Mechanical (pg 4) for: Plumbing• and Gas Piping (pg 5)) . . Company Name: Mailing Address: Contact Person: E -Mail Address: Contractor Registration Number: ARCHITECT OF RECORD - All plans must be wet stamped by Architect of Record Company Name: Kenneth L. Butts Architect A.I.A Mailing Address: 124 Stagecoach Road Contact Person: Kenneth Butts E -Mail Address: kbaia @adelphia.net Company Name: Donn Penn Consulting Engineers Mailing Address: 635 Westport Parkway H:Wpplicatious\Fonns- Applications On Line \2009 Applications \I -2009 - Permit Appthcation.doc Revised: 1 -2009 blt Day Telephone: (860) 783 -5670 South Windsor CT City State Fax Number: (860) 783 -5680 City Day Telephone: Fax Number: Expiration Date: Bei1 Canyon ENGINEER OF RECORD - All plans must be wet stamped by Engineer of Record Grapevine State CA City State Day Telephone: (818) 999 -4272 Fax Number: (818) 999 -4321 City State Contact Person: Donn Penn Day Telephone: (817) 410 -2858 E -Mail Address: Fax Number: (817) 251 -8411 06074 Zip Zip 91307 Zip TX 76051 Zip Page 1 of 6 BUILDING PERMIT INFORMATION - 206 - 431 -3670 Valuation of Project (contractor's bid price): $ 55,000 Existing Building Valuation: $ Scope of Work (please provide detailed information): Sales area: entry mat, wood plank flooring, base, surface mtd. standards, floor fixtures, Ceiling - Halide track fixtures (B1) & semi recessed wall wash fixture (B), Speakers (S), Stockroom /Office: surface mounted. standards, floor fixtures Will there be new rack storage? ❑ Yes 0.. No If yes, a separate permit and plan submittal will be required. Provide All Building Areas in Square Footage Below PLANNING DIVISION: Single family building footpnnt (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) *For an Accessory dwelling, provide the following: Lot Area (sy ft): Floor area of principal dwelling: Floor area of accessory dwelling: *Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard: Compact: Handicap: Will there be a change in use? ❑ Yes ❑ No If "yes ", explain: FIRE PROTECTION/HAZARDOUS MATERIALS: ❑ Sprinklers ❑ Automatic Fire Alarm m None ❑ Other (specify) Will there be storage or use of flammable, combustible or hazardous materials in the building? ❑ Yes ❑ No If "yes', attach list of materials and storage locations on a sept 8-1/2" .r 11" paper including quantities and Material Safety Data Sheets SEPTIC SYSTEM ❑ On -site Septic System — For on -site septic system, provide 2 copies of a current septic design approved by King County Health Department. H:tApplications\Forms- Applications On Line Applications \1 -2009 - Pemut Appltcatton:doe Revised: 1 -2009 bit Page 2 of 6 Existing Interior Remodel Addition to Existing Structure New Type of Construction per IBC Type of Occupancy per IBC Is' Floor I IB M Vi Floor 3` Floor Floors thru Basement Accessory Structure* Attached Garage Detached Garage Attached Carport Detached Carport Covered Deck Uncovered Deck BUILDING PERMIT INFORMATION - 206 - 431 -3670 Valuation of Project (contractor's bid price): $ 55,000 Existing Building Valuation: $ Scope of Work (please provide detailed information): Sales area: entry mat, wood plank flooring, base, surface mtd. standards, floor fixtures, Ceiling - Halide track fixtures (B1) & semi recessed wall wash fixture (B), Speakers (S), Stockroom /Office: surface mounted. standards, floor fixtures Will there be new rack storage? ❑ Yes 0.. No If yes, a separate permit and plan submittal will be required. Provide All Building Areas in Square Footage Below PLANNING DIVISION: Single family building footpnnt (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) *For an Accessory dwelling, provide the following: Lot Area (sy ft): Floor area of principal dwelling: Floor area of accessory dwelling: *Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard: Compact: Handicap: Will there be a change in use? ❑ Yes ❑ No If "yes ", explain: FIRE PROTECTION/HAZARDOUS MATERIALS: ❑ Sprinklers ❑ Automatic Fire Alarm m None ❑ Other (specify) Will there be storage or use of flammable, combustible or hazardous materials in the building? ❑ Yes ❑ No If "yes', attach list of materials and storage locations on a sept 8-1/2" .r 11" paper including quantities and Material Safety Data Sheets SEPTIC SYSTEM ❑ On -site Septic System — For on -site septic system, provide 2 copies of a current septic design approved by King County Health Department. H:tApplications\Forms- Applications On Line Applications \1 -2009 - Pemut Appltcatton:doe Revised: 1 -2009 bit Page 2 of 6 I Date Application Accepted: 1 �I L� I �� Date Application Expires: l/lx [ 7_ , Staff Initials: A I r PERMIT APPLICATION NOTES — Applicable to all permits in this application Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. Building and Mechanical Permit The Building Official may grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). Plumbing Permit The Building Official may grant one extension of time for an additional period not exceeding 180 days. The extension shall be requested in writing and justifiable cause demonstrated. Section 103.4.3 Uniform Plumbing Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING O R OR AUT ORIZED AGENT: Signature: • Print Name: Bryant Daniel Mailing Address: Cadd Tech Design, Inc., 225 Oakland Rd,Suite 105 H:\Applications \Forms- Applications On Line\2009 Applications \1 -2009 - Permit Application.doc Revised: 1 -2009 bi, City Date: I) • 2('7 • 0Q Day Telephone: (860) 783 -5670 South Windsor CT 06074 State Zip Page 6 of 6 Receipt No.: R10 -00132 Initials: User ID: Payee: JEM 1165 ACCOUNT ITEM LIST: Description BUILDING - NONRES STATE BUILDING SURCHARGE City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Fax: 206 - 431 -3665 Web site: http://www.ci.tukwila.wa.us Parcel No.: 7888920020 Permit Number: D09 -269 Address: 17250 SOUTHCENTER PY TUKW Status: APPROVED Suite No: Applied Date: 12/22/2009 Applicant: CARTERS BABIES AND KIDS Issue Date: LAKEVIEW CONSTRUCTION INC. TRANSACTION LIST: Type Method Descriptio Amount Payment Check 244856 965.30 Authorization No. Account Code Current Pmts 000.322.100 640.237.114 RECEIPT Total: $965.30 • Payment Amount: $965.30 Payment Date: 01/27/2010 10:17 AM Balance: $0.00 960.80 4.50 PAYMENT RECEIVED doc: Receipt -06 Printed: 01 -27 -2010 Receipt No.: R09 -02041 Payee: CADD TECH DESIGN, INC ACCOUNT ITEM LIST: Description PLAN CHECK - NONRES City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us TRANSACTION LIST: Type Method Descriptio Amount Payment Check 282 624.52 Authorization No. RECEIPT Total: $624.52 Parcel No.: 7888920020 Permit Number: D09 -269 Address: 17250 SOUTHCENTER PT TUICW Status: PENDING Suite No: Applied Date: 12/22/2009 Applicant: CARTER'S Issue Date: Payment Amount: $624.52 Initials: JEM Payment Date: 12/22/2009 03:40 PM User ID: 1165 Balance: $965.30 Account Code Current Pmts 000.345.830 624.52 PAYMENT RECEIVED doc: Receipt -06 Printed: 12 -22 -2009 Project: p L ' 1�✓�1 -S j4 9•It.J i f�'+ 5 Type of Inspec ' on: , 1 F rUtJ t i �1 Address: . t `? 2.S 56 . f.,fr to,d4 Date Called: E L� (. Special Instructions: ./ late Wanted �S' / ' a.m. p.m. Requester: Phone 71 ^ / -kl 7i INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 A p proved per applicable codes. Corrections required prior to approval. COMMENTS: . l w( s a-- A P Insp or: Date: EJ $60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: 'Date: COMMENTS: t) new._ ci o 4:IN (L00/ e rte. dre Address: sss: t f 2. s' 0 P t`s — Z d deo Pod, f2 L . u ems c. t` 1,.m 0 k /9( ' --•r LW-- i . -0 IS c a - -- iJ d 3 .7 C) to b l :. n ? l�Q kit )t 4( t k J, �N 6 J 1 A[ hr' 5(AN I I Requester: Phone No: _ &,E(4 _ o a .s-j Project: A C (Av- c! J� r t s A k .4s ( d Type o spectig(n: O / p M Y v 1 �(., , At, dre Address: sss: t f 2. s' 0 56 p ew Date Called: Sp Instruc G ecial G n r / . 5 ,../ Afrt eto°° Date Wanted:3 _ I 0 s ` i Requester: Phone No: _ &,E(4 _ o a .s-j INSPECTION NO. El Approved per applicable codes. INSPECTION RECORD Retain a copy with permit o off' -z q PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 Corrections required prior to approval. Inspect r: Date: s -4- / 3 ri $60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. 41 1 Receipt No.: 'Date: Project: G a (40. Sprinklers: Fire Alarm: Type of Inspection: Address: i 7 2 3", 5c 'Z es s: i Suite #: /cjy ' -Permits: t Person: , Special Instructions: . Phone No.: .Needs Shift Inspection: . Sprinklers: Fire Alarm: Hood & Duct: Monitor: Pre -Fire: -Permits: Occupancy Type: " • Approved per applicable codes. Inspector: iv 3f3 Word /Inspection Record Form.Doc 1/13/06 INSPECTION RECORD Retain, a copy with permit INSPECTION NUMBER PERMIT NUMBERS CITY OF TUKWILA FIRE DEPARTMENT 444 Andover Park East, Tukwila, Wa. 98188 206 =57 -4407 Corrections required prior to approval. COMMENTS: ) . I Date: 3 /L /l/ Hrs.: $80.00 REINSPECTION FEE REQUIRED. You will receive an invoice from the City of Tukwila Finance Department. Call to schedule a reinspection: T.F.D. Form F.P. 113 03/05/2013 ©8:30 2b28573102 03/0412010 20:12 FAX 310 390 4321 KEEN Burrs March 4, 2010 NEKNEiN 1.9L71"ftl • pCYfl :,.:..: ... ,..':. TEt AiA� 2- y' Tf, GECOaCM BE1. l ANY0N. C4U"CW+IACW61•pi10Ne 07ar974 R:UC wig) O3• City of Tukwila Community Dev. Dept. / public Wanks Dept. Permit Center 6300 Southatu.a Boulevard, Suite 00 Tukwila, WA 98188 Attn: Carol RE: Review Comments Carters # T D Sou.thcenter Square 0250 Soutbcenter Parkw Tukwila, WA 95188 Y IENN BUTTS ALA LAKEVIEW CONSTRUCTIN V Dear Carol: Herewith we are responding to your walk thru comments on March 4, 2010. The rear service door does not regnire a titre rating. This response letter will serve to amend The ounent construction do i uuaems. (End of Commas) I hope you Dud the response to yon comment acceptable as we fully intend to comply with it requirements of the City of Tukwila and all local and state codes. Very truly yours, Kenneth Butts, Architect AlA ios REGISTERED ARCHITECT KENNETH L. ?L17 STATE OF WASHINGTON 47&1002 PAGE 02/02 2006 Washinton State Energy Code Compliance Form Space Calculation Space Type: Space Area (sf): 4000 sf Retail Allowed Wattage per Table 15 -1: 1.5 Space Allowed Wattage: 6000 W /sf W Description Lamp Mark Fixture Wattage Fixture Quantity Total I ( 2) 541W T-5 A 2) 54 tW T=5 2) 32 W T-8 2)32WT -8 ) 70W 70W 2 W T-8 F Merchandise Display Allowance Total = 7874 W Space Type: Retail Allowance Wattage per Table 15 -1 footnote 10: 1.5 W /sf Display Area (sf): 1312 Merchandise Display Allowance Wattage: 1968 W Total Allowance REVIEWED FOR CODE COMPLIANC E APPROVED City of Tukwila I BUILDING nwMSinN FILE COPY Nn. Space Allowed Wattage: erchandise Display Allowance Wattage: Total Allowance: RECEIVED CITY OF Ti UKWI A DEC 22 M PERMIT CENTER 9D1- 2ia1 1,2EPARTME Pub A r Pu b iorks Complete Vj Comments: DETERMINATION OF COMPLETENESS: (Tues., Thurs.) REVIEWER'S INITIALS: -to APPROVALS OR CORRECTIONS: • JEW GOORD C ye' PLAN REVIEW /ROUTING SLIP Structural Incomplete ❑ ACTIVITY NUMBER: D09 -269 DATE: 12 -22 -09 PROJECT NAME: CARTERS BABIES AND KIDS SITE ADDRESS: 172 SOUTHCENTER PY, STE 144 X Original Plan Submittal Response to Incomplete Letter # Response to Correction Letter # Revision # after Permit Issued 4/ AAPC ir/ 11 " Fire Prevention anning 'vision n Permit Coordinator ❑ DUE DATE: 12-24-09 Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: TUES/THURS ROUTING: Building Please Route 5, Structural Review Required ❑ No further Review Required n DATE: Not Applicable DUE DATE: 01-21-10 Approved ❑ Approved with Conditions ❑ Not Approved (attach comments) ❑ Notation: REVIEWER'S INITIALS: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: Documents/routing slip.doc 2 -28 -02 DATE: C Bond Bond Company Name Bond Account Number Effective Date Expiration Date Cancel Date Impaired Date Bond Amount Received Date 4 TRAVELERS & STY CO OF AMER 400MJ9662 04/23/2006 Until a Cancelled n 01/01/1980 ARCHIVED $12,000.0002/17 /2006 3 USF &G 46013010271937 01/01/2002 04/23/2006 $12,000.00 01/11/2002 2 USF &G CO 46013010271937 04 /23/1998 01/01/2002 $6,000.00 1 USF &G CO 46011010271937 04/23/1993 04/23/1998 $6,000.00 License Name Type Specialty 1 Specialty 2 Effective Date Expiration Date Status STATECC113B3 STATE CONST CORP OF S E WISC CONSTRUCTION CONTRACTOR GENERAL UNUSED 1/23/198912/9/1993 01/01/1980 ARCHIVED Name Role Effective Date Expiration Date SUNDAY, EUGENE R PRES 01/01/1980 MOON, KENT A VP 01/01/1980 SUNDAY, EUGENE R SECRETARY 01/01/1980 MOON, KENT A TREASURER 01/01/1980 Untitled Page General /Specialty Contractor A business registered as a construction contractor with L &I to perform construction work within the scope of its specialty. A General or Specialty construction Contractor must maintain a surety bond or assignment of account and carry general liability insurance. Business and Licensing Information Name Phone Address Suite /Apt. City State Zip County Business Type Parent Company LAKEVIEW CONSTRUCTION INC 4146574222 10505 CORPORATE DR, #200 PLEASANT PRAIRIE WI 53158 OUT OF STATE Corporation UBI No. Status License No. License Type Effective Date Expiration Date Suspend Date Specialty 1 Specialty 2 601447862 ACTIVE LAKEVCI072KC CONSTRUCTION CONTRACTOR 5/3/1993 1/13/2011 GENERAL UNUSED Other Associated Licenses Business Owner Information Bond Information • I Page 1 of 2 https:// fortress .wa.gov /lni /bbip/Detail.aspx 01/27/2010 • • RESPONSIBILITY SCHEDULE NOTES: a) CONSTRUCT ON. ANY D SCREPANG E SHALL BE REPORTED TO TENAN CONSTRUCTION ROJEC T MANAGER. BEGINNING DESCRIPTION DIVISION 01000 - GENERAL LANDLORD BUILDING PERMIT SUBMITTAL LANDLORD BUILDING PLAN GHEGK FEES LANDLORD BUILDING PERMIT FEES TENANT BUILDING PERMIT SUBMITTAL TENANT BUILDING PLAN CHECK FEES TENANT BUILDING PERMIT FEES DEMOLITION LANDLORD GLEAN -UP #I AT TURN -OVER TENANT G.G. FINAL CLEAN -UP #I AT TURN -OVER TENANT G.G. FINAL GLEAN -UP #2 AT PRE - OPENING NEUTRAL PIERS AND MALL BULKHEAD OTHER PERMITS, FEES, INSURANCE TEMPORARY POWER TEMPORARY BARRICADES TEMPORARY BARRICADE GRAPHICS TRASH REMOVAL/DISPOSAL AND DUMPSTERS DUMPSTER AT TURNOVER FINAL INSPECTIONS AND CERTIFICATE OF OCCUPANCY DIVISION 03000 - CONCRETE WORK CONCRETE TRENCH FOR NEW PLUMBING CONCRETE TRENCH FOR GASHDESK POWER CONCRETE POUR BACK FOR LEAVE OUT DIVISION 05000 - METALS DEMISING PARTITION FRAMING DEMISING PARTITION FURRING TOILET ROOM WALL FRAMING STOCKROOM WALL FRAMING OFFICE WALL FRAMING COLUMN ENCLOSURE FRAMING MASONRY WALL METAL FURRING DIVISION 06000 - WOOD AND PLASTICS ROUGH CARPENTRY, TENANT WORK, INTERIOR WOOD TRIM, TENANT WORK BLOCKING (FIRE RETARDANT LUMBER 4 PLYWD) AIR INFILTRATION BARRIER SEALANT AND CAULKING FIRE STOPPING ROOF NG/FLASHI NG WATERPROOF MEMBRANE "WET AREAS" DIVISION 08000 — DOORS 4 WINDOWS STOREFRONT ENTRY DOORS STOREFRONT ALUMINUM FRAMING AND GLASS INTERIOR DOORS, FRAMES, INTERIOR DOOR LEVER 5ET5 REAR SERVICE DOOR, FRAME 4 HARDWARE REAR SERVICE DOOR EXIT DEVICE SYSTEM A -OK SECURITY LOCKS AND GORES DIVISION 09000 - FINISHES CEILING SUSPENSION SYSTEMS ACOUSTICAL TILES (SALES) ACOUSTICAL TILES (NON - SALES) GYP. BD. CEILING (SALES) GYPSUM WALL BOARD (DEMISING PARTITION) GYPSUM WALL BOARD (HG TOILET ROOM PARTITIONS) GYPSUM WALL BOARD (STOCK ROOM PARTITION) GYPSUM WALL BOARD (COLUMN ENCLOSURES) GYPSUM WALL BOARD (OFFICE/HALL) GYPSUM WALL BOARD (MOP SINK AREA) SALES AREA FLOORING SHEET VINYL FLOORING (TOILET ROOM) VCT (OFFICE /STOCK/HALL) WALL BASE (SALES) VINYL BASE (OFF I GE/STOCK/HALL) REDUCER STRIPS, ADHESIVE, ETC. FLOOR PREP, INCLUDING LEVELING FLOOR PROTECTION PAINTING, FINISHING SALES AREA PAINTING, FINISHING NON -SALES AREA CORNER GUARDS DIVISION 10000 - SPECIALTIES STOREFRONT ILLUMINATED SIGNS BLADE SIGN INTERIOR 5IGN5 LOGO 510115 "COMING SOON" SIGN EMPLOYMENT "NOW HIRING" 5IGN5 TOILET ACCESSORIES (OTHER THAN NOTED BELOW) TOILET ACCESSORIES : PAPER TOWEL HOLDER, TOILET PAPER HOLDER, SOAP DISP. STORAGE CABINET KOALA CHANGING STATION TOILET ROOM UTILITY CABINET H.G. GRAB BARS ACCESSIBILITY SIGNAGE FIRE EXTINGUISHERS DIVISION 11000 - EQUIPMENT SHOPPER TRACK SECURITY SYSTEM P05 EQUIPMENT "GASH REGISTERS" COMPUTER SYSTEMS REFRIGERATOR / MICROWAVE / LOCKERS / BREAK TABLE SAFE AUDIO EQUIPMENT AND SPEAKERS DIVISION 12000 - FURNISHINGS GASHDESK FLOOR FIXTURES SURFACE MOUNT WALL STANDARDS HARDWARE AND BRACKETS FOR STANDARDS ROLLING SAFETY LADDER HARDWARE STORAGE UNIT OFFICE COUNTERS G.G. SUPPLY • • • • • • • • • • DIVISION 01000 - THERMAL d MOISTURE PROTECTION FIBERGLASS BATT INSULATION • • • • INSTALL • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • GARTERS SUPPLY • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • INSTALL • • • • • • • • • • • • • LANDLOR AS-IS • • • • • • • • • • • • • • • BY LL • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • REMARKS BY TENANTS PERMIT VENDOR G.G. SHALL PICK UP PERMIT AND PERMIT FEES BUILDING PERMIT FEES N/A COORDINATE WITH STORE MANAGER EXISTING IF REQUIRED FOR STOREFRONT WORK G.G. TO EMPTY DUMPSTER PRIOR TO MERCHANDISE ARRIVAL COORDINATED WITH TENANTS ARCHIGTEGT N/A EXISTING EXISTING GENERAL WHERE REQUIRED BY NEW WORK WHERE ANY NEW REQUIRED N/A SEE DOOR SCHEDULE, SEE DOOR SCHEDULE, SEE DOOR SCHEDULE, SEE DOOR SCHEDULE, SEE DOOR SCHEDULE N/A SEE SHEET AI.2 FOR SPECIFICATION TENANT SIGN CONTRACTOR TENANT SIGN CONTRACTOR INTERIOR GRAPHICS BY TENANT VENDOR INTERIOR GRAPHICS BY TENANT VENDOR LANDLORD TO INSTALL LANDLORD TO INSTALL LANDLORD TO INSTALL WHERE REQUIRED INSTALL BY TENANT VENDOR G.G. TO COORDINATE WITH CHECKPOINT INSTALL BY TENANT VENDOR GOMM WORKS, CONTRACTED BY G.G. INSTALL BY TENANT VENDOR GOMM WORKS, CONTRACTED BY G.G. BOLT TO FLOOR WITH EXPANSION ANCHORS INSTALL BY TENANT VENDOR DESCRIPTION DIVISION 15000 - MECHANICAL HVAG EQUIPMENT "ROOF TOP" ROOF WORK AND EQUIPMENT CURBS HVAG DISTRIBUTION, DUCTWORK DIFFUSERS EXHAUST FANS AND VENTING STOCKROOM UNIT HEATER SMOKE DETECTORS FIRE SPRINKLER MAIN SPRINKLER SYSTEM SPRINKLER SYSTEM MODIFICATIONS PLUMBING FIXTURES (TOILET ROOMS) DRINKING FOUNTAIN WATER AND SEWER STUB SANITARY PIPING DOMESTIC WATER PIPING ACCESS PANELS WATER HEATER MOP SINK, MOP HANGER AND HOSE DIVISION 16000 - ELECTRICAL ELECTRICAL SERVICE CONDUIT TO TENANT SPACE ELECTRICAL SERVICE ELECTRICAL PANELS TRANSFORMER FIRE ALARM SYSTEM EMERGENCY LIGHTING EXIT SIGNS FLUORESCENT LIGHT FIXTURES FLUORESCENT LAMPS AGGENT LIGHT FIXTURES ACCENT LIGHT LAMPS THERMOSTATS WIRING, CIRCUITING, RECEPTACLES, SWITCHES WIRING, CIRCUITING, RECEPTACLES, SWITCHES WIRING AND CONNECTION OF GASHWRAP TIME CLOCK, FOR STOREFRONT SIGN ALL LOW VOLTAGE TELEPHONE AND DATA GAT -5 WIRING SHOPPER TRACK (J -BOX 4 CONDUIT) SHOPPER TRACK (GABLE) TELEPHONE CONDUIT AND PULL STRING WIRING TELEPHONE SERVICE LIGHTING SPECIALTY STORE LIGHTING 35 INDUSTRIAL PARK RD. GENTERBROOK, GT Larry De Francesco (860) 161- 0110x204 FLOORING 5G5 FLOORING SYSTEM 530 S. MAIN ST. SUITE 110 ORANGE, GA '12868 BARRY SCHWARTZ (114) 542 -2146 PROJECT DATA / DIR PROJECT NAME: PROJECT DESCRIPTION: TENANT COORDINATOR: TENANT: CODE SUMMARY APPLICABLE CODES: BUILDING CODE: MECHANICAL CODE: PLUMBING CODE: ELECTRICAL CODE: ENERGY CODE: ACCESSIBILITY: 100 SALES AREA 101 HALLWAY 102 H.G. TOILET ROOM WOMENS 103 H.G. TOILET ROOM MENS 104 OFFICE 105 STOCK ROOM TOTAL: 3301 S.F. 108 5.F. 58 S.F. 64 S.F. - 13 S.F. 5q6 5.F. G.G. SUPPLY INSTALL • • • • • • CLAUDINE SIEDLER WIG PROPERTIES LLG 4811 -134TH PLAGE SE BELLEVUE, WA .18006 CHAPTER 10 MEANS OF EGRESS OCCUPANCY CALCULATIONS: TABLE 1004.1.1 ROOM OCCUPANT ROOM DESCRIPTION AREA FACTOR 30 0 0 0 100 300 • • • • • • • • • CARTERS RETAIL W5161 KENNEDY DRIVE FOND DU LAG, WI 54135 Ms. Brenda Schainske Project Manager TEL: (120) 332 -0420 GARTERS SUPPLY INSTALL • • • OCCUPANT LOAD 110 0 0 0 1 2 4,000 S.F. 112 • LANDLORD AS-IS BY LL • • • 2 EXITS REQUIRED YES NO NO NO NO NO YE5 EGRESS WIDTH PER OCCUPANT: TABLE 1005.1 INCHES PER PERSON I.) EGRESS COMPONENTS (WITH SPRINKLERS) 0.15 INCHES PER OCCUPANT x 112 OCCUPANTS = 11 INCHES (REQUIRED) 2.) ACTUAL WIDTH PROVIDED THROUGH FRONT: THROUGH FRONT AREA (PAIR 3' -O:" DOORS = 68" CLEAR 3.) ACTUAL WIDTH PROVIDED THROUGH REAR: THROUGH REAR (I) 3' -0" DOOR = 34" CLEAR TOTAL EGRESS WIDTH PROVIDED: =102" CLEAR • • • • • • • • • • • • • • • • • • • • • • • • • • N/A REMARKS N/A TENANT VENDORS: Date: 17,-3,1-per WOOD FIXTURES LEIDEN CABINET COMPANY 2385 EDISON BOULEVARD TWINSBURG, OH 44081 Mike Hopp (330) 425 -8555 SIGNS IMAGE CONSULTING SERVICES 1115 Donwe I I S. Euclid, OH 44121 Patrick O'Dea (440) c151- cicilq ECTORY: CARTERS, SPACE NO. 144 PROJECT COORDINATOR: AOUTHGENTER SQUARE 11250 SOUTHGENTER PKWY TUKWILA, WA '18188 CHILDRENS CLOTHING STORE AND RELATED APPAREL TENANTS ARCHITECT: TENANTS ENGINEER: BUILDING DEPT.: 2006 International Building Gode- Chapter 51 -50 WAG 2006 International Mechanical Code (IMG 06)- Chapter 51 -52 2006 Uniform Plumbing Code (Chapters 51 -56 and 51 -51 WAG) 2008 National Electrical Code (NFPA 10) 2006 Washington State Energy Gode - Chapter 51 -II WAG 2003 ICG /ANSI A111.1 1015.2.1 TWO EXIT ACCESS DOORWAYS: Exception #2 Not located less than one third of the overall diagonal dimension of the area being served. FILE COPY Permit No., n_ire. 240q Pan review approval is subject to errors and omissions. Approval of construction documents does lot authorize tho violation of any adopted code or ordinance. Receipt r> �, I :. : S J0 : I 1 b.1 I s 1 • I I owledged: EXISTING EXISTING By Rate: / 2/ (0 NEW SERVICE SEE ELECTRICAL DRAWINGS. NEW SERVICE SEE ELECTRICAL DRAWINGS. NEW BY LANDLORD NEW BY LANDLORD SEE LIGHT FIXTURE SCHEDULE SEE LIGHT FIXTURE SCHEDULE, RETAIL AREA TO BE GLG MOUNTED SEE LIGHT FIXTURE SCHEDULE SEE LIGHT FIXTURE SCHEDULE SEE LIGHT FIXTURE SCHEDULE SEE LIGHT FIXTURE SCHEDULE TENANT SPEC, LIGHTSTAT MODEL THE -POI ALL LANDLORD ITEMS SEE E -I AND E -2 ALL TENANT ITEMS SEE E -I AND E -2 SEE ELECTRICAL DRAWING E -2 City Of iUlkwila BUILDING DIVISION G.G. TO CONTRACT WITH GOMM WORKS FOR INSTA G.G. TO CONTRACT WITH GOMM WORKS FOR INSTA EXISTING, G.G. TO RELOCATE IF REQUIRED G.G. TO COORDINATE WITH TENANT FOR PHONE SERVICE LOCKS / A -OK SECURITY DOOR HDW. (811) 265 -2100 Gar lgoa-oksecurity LOW VOLTAGE GOMM - WORKS, LLG CONTRACTOR 3550 ANNAPOLIS LAND N. PLYMOUTH, MN 55441 Tel. 136- 852 -3100 DON KAMM GADD TECH 225 Oakland Rd., Sulte 105 South Windsor, GT 06014 Tel. (860) 183 -5610 KENNETH L. BUTTS, ARCHITECT 124 STAGE COACH ROAD BELL CANYON, GA .11301 TEL: (818) qqq -4212 FAX: (818) -qqq -4321 DONN PENN, CONSULTING ENGINEER 635 WESTPORT PARKWAY, SUITE 300 GRAPEVINE, TEXAS 16051 Tel. 811 -410 -2858 DEPARTMENT OF COMMUNITY DEVELOPMENT 6300 SOUTHGENTER GLVD, #100 TUKWILA, WA '18188 ATT: BUILDING OFFICIAL (206) 431 -3655 BUILDING DATA: !NAG USE GROUP: CONSTRUCTION TYPE: IIB GROSS FLOOR AREA: OCCUPANCY LOAD: SPRINKLER: FIRE ALARM: FIRE EXTINGUISHERS: TABLE 4 -I RETAIL OR WHOLESALE STORES WATER CLOSET: MALE I:1 -100 PROVIDED I FEMALE I:I -25 PROVIDED SERVICE SINK: NOT REQUIRED PROVIDED: I w Approved Bv: (M) Mercantile 4,000 S.F. 112 Yes NFPA 13 Yes NFPA 12 Yes NFPA 10 MINIMUM PLUMBING FIXTURES (EXISTING) 2006 UNIFORM PLUMBING CODE, CHAPTER 4 SEPARATE PERMIT REQUIRED FOR: i0 Mechanical Electrical plumbin as Piping City of Tukwila BUILDING DIVISION 412.5 Facilities in Mercantile and Business Occupancies Serving Customers TABLE "A" OCCUPANT LOAD FACTOR GROUP "M" 200 / 4000 S.F. = 20 PERSONS 10 MALE / 10 FEMALE LAVATORY: ONE FOR EVERY TWO WATER CLOSETS PROVIDED 2 PROVIDED MALE : I PROVIDED FEMALE : I DRINKING FOUNTAINS: O:1 -30 NOT REQUIRED PROJECT DRAW ARCHI c 17 TUKW PROJECT KEY PL GARTERS SOUTHGENTER SG TUKWILA, WAS 1 I&18 SPACE NO. 144 PLANNING APPROVED _._...�. No changes can be made. to these tans without approval from the Planning Division of DCD AO.I L AI.I AI.2 F A 13 AI.4 F A2.I A3.2 A33 A4.I A4.2 A5.I M.E.P El E2 E4 E5 MI 1016.1 MAXIMUM TRAVEL: 250 feet sprinklered 10Ic1.1 MINIMUM NUMBER OF EXITS: 1-500 Occupants / 2 Exits required babies and kids SOUTHCENTER SQUARE 250 SOUTHCENTER PKWY ILA, WA AREA 4,000 SO/FT TENANT SPACE No 144 AN arter's UARE $24. VAtilitkit.14:4M1 CROUP. VIM BalrftICIEWM4 PARXWAY iaNeuf ei 111 —161 emipt p At, - F, 41 7:54.1•5, SouthcenterSim REVISIONS No changes shall be made to the scope of work without prior approval of Tulovila !vision. NG INDEX NOTE: Revisions will require a new_plansuhmittai TECTURAL and may Include additional plan review fees. socevaattenactis ITLE, INDEX, KEY PLAN, RESPONSIBILITY SCHEDULE, PROJECT ATA OOR SCHEDULE, DOOR TYPES AND DOOR HARDIA1ARE, GENERAL ONTRAGTOR NOTES EASEOUTLINE FLOOR AND STRUCTURE PLAN ONSTRUCTION PLAN (LANDLORD WORK) LOOR FINISH PLAN / FINISH SCHEDULE / ROOM FINISH SCHEDULE ALL STANDARDS INSTALLATION PLAN REFLECTED CEILING PLAN STOREFRONT ELEVATIONS, DETAILS, EXTERIOR SIGNS SALES AREA, ELEVATIONS, KEY PLAN TOILET ROOM, PART PLAN E$ ELEVATIONS STOCKROOM Et OFFICE, PART PLAN, ELEVATIONS INTERIOR SECTIONS AND DETAILS INTERIOR SECTIONS AND DETAILS STOCKROOM SHELVIN6 DETAILS ROOF PLAN / HVAG UNIT INSTALLATION ENGINEERING LECTRICAL DETAILS 01A1 VOLTAGE DIAGRAMS ELECTRICAL SPECIFICATIONS FLOOR PLAN - MECHANICAL WORK M2 MECHANICAL SPECIFICATIONS PI FLOOR FLAN - PLUMBING WORK REVIEWED FOR CODE COMPLIANCE APPROVED ( T BUILDING DIVIRinni RECEIVED CITY OF TUKVVILA DEC 2 2 2009 PERMIT CENTER po°t--2e°■ DATE: II/IS/09 DRAWN: STAFF CHECKED: KB KENNETH L. BUTTS ARCHITECT AIA 124 STAGECOACH ROAD BELL CANYON, CA 91307 (818) 999-4272 REGISTERED KENN L. BUTTS STATE OF WASHINGTON CADDTECti 225 OAKLAND RAM, WITE 105 1EL: MO 183-5610 SOUTH 111114D5OR, CT 06014 MX: (860) 183-5680 13C 0 8 2009 w co • W t 0 < STORE NUMBER #TBD REVISIONS 'A'-ISSUE: LANDLORD COMMENTS DATE: 12/1/09 DATE DATE DATE SHEET TITLE wro -D C 8 .1) TTTLE SHEET SCALE NONE SHEET NUMBER HARDWARE SCHEDULE .r SUPPLY INSTALL 0 EXISTING AS IS, FIELD VERIFY • FURNISH & INSTALL BY G.C. 0 FURNISH BY TENANT & INSTALL BY G.C. 0 FURNISH & INSTALL BY LANDLORD WOG J.11N O 11VH O t TOILET ROOM C I STOCKROOM IO O O REAR EXIT LATCH :E FUNCTION LOCK S9N IH EXISTING (VERIFY) 0 HEAD TYPE JAMB SIZE REMARKS WIDTH 0 THK. MAT. AS PROVIDED BY ENTRY DOOR MANUFACTURER EX EX I CD STOREFRONT ENTRY PAIR 3� -p�� 7' -p" Iy2 PR. 42' X 4,I ' STANDARD WEIGHT, FULL - MORTISE, 5 KNUCKLE, BALL- BEARING HINGES WITH US26D FINISH, BOMMER 4SBB5000 -450 -652, OR EQUAL ALUM. GLASS ® ® ® ® 0 ENTRY --- (I) FULL MORTISE, THREE KNUCKLE SPRING HINGE MOUNT IN CENTER (FINISH US260) EX EX 4 I/2" EXISTING ENTRY DOOR SYSTEM BY LANDLORD, A -OK LOCK INSTALLED BY G.G. LL LL I ® SALES TO HALL WITH NON REMOVEABLE SECURITY PINS 0 I -3/4" W S OO G D PLAM PL-2 MEGA METAL 0 NONE LEVER 511X V SI?J1N� EXISTING (VERIFY) 0 B B 7 1/4" TENANT G.G. TO LAMINATE DOOR WITH WHITE PLASTIG LAMINATE LL LL 2 0 PUSH /PULL PROVIDED BY ENTRY DOOR MANUFACTURER 3' -O" 7' -0" I - 3/4" WO S.G. OD PAINT PT -2 M EGA ETAL PT PAINT -2 NONE A -OK LOCK • - ° 5 B B o DOOR, FRAME AND HARDWARE BY LANDLORD, LL LL BATTERY - ALARMED PANIC DEVICE, DETEX VALUE SERIES V4OXEB O HALL TO STOCKROOM 3 ' - O" 8' - O" I -3/4" 0 PAINT PT -2 MEGA METAL A -OK MORTISE CYLINDER W/ LAZY L GAM NONE LEVER PASSAGE - -- D 0 B I / LATCH PROTECTOR, IVES #LG7, OR EQUAL LL LL I ® OFFICE DOOR 3 ' -O" 0 I -3/4" S.C. WOOD WIDE -ANGLE PEEPHOLE, IVES #618, B26D FINISH, OR EQUAL I6GA METAL PAINT PT -2 NONE LEVER ENTRY 0 B B THRESHOLD AND WEATHER - STRIPPING 0 DOOR, FRAME AND HARDWARE BY LANDLORD, EX EX I 0 3' -O" 7' -O" DOOR PULL, IVES 1 -6, US26D FINISH, OR SIMILAR HOLLOW METAL INSUL PAINT PT -2 MEGA METAL PAINT PT -2 ALUM. 0 ENTRY 10 MIN. G EX EX 7 I/4" EXISTING BUILDING STANDARD SERVICE DOOR, FRAME. PROVIDE ALL REQUIRED HARDWARE. SEE HARDWARE SCHEDULE. S15H91V - 1 V >901 EXISTING (VERIFY) ALL TO BE MEDIUM, COMMERCIAL LOCKS WITH LEVER HANDLES: 0 0 0 • LEVER SET: PASSAGE LATCH (BOTH LEVERS ALWAYS UNLOCKED), SCHLAGE #SIOD, NEPTUNE DESIGN, 626 FINISH, OR EQUAL 0 0 ENTRANCE LOCK (TURN- BUTTON INSIDE, KEY OUTSIDE), SCHLAGE #S5IPD, NEPTUNE DESIGN, 626 FINISH, OR EQUAL 0 REPLACEMENT LOCK BY A -OK, CYLINDER PROVIDED BY TENANT LEVER SET: PRIVACY LOCK (PUSH- BUTTON LOCK), SCHLAGE #540D, NEPTUNE DESIGN, 626 FINISH, OR EQUAL ® STANDARD 4" ALU.M DOOR PULLS PROVIDED BY G.G. KICK PLATES CLOSERS EXISTING (VERIFY) 0 MOUNT CLOSER ON INSIDE OF DOOR 0 0 0 0 AS PROVIDED BY ENTRY DOOR MANUFACTURER 0 BARRIER -FREE, SURFACE- MOUNTED DOOR CLOSER, NORTON #1601BF -681, ALUMINUM FINISH, OR EQUAL 0 0 0 0 0 REVIEWED FOF EXISTING (VERIFY) CODE COMPLIAN MOUNT ON PUSH SIDE OF DOORS ONLY 8) APPROVED 8 "H. X 34 "W. STAINLESS STEEL KICK PLATE, IVES 148400 532D -8X34, OR EQUAL 0 0 0 0 36 "H. X 36 "W. STAINLESS STEEL KICK PLATE JAN 0 ( 2010 DOOR STOPS EXISTING (VERIFY) FLOOR DOME STOP (FIELD VERIFY CONDITION), IVES 44FS436 (WITHOUT THRESHOLD) OR IVES #FS438 (WITH THRESHOLD OR UNDERCUT), FINISH . U526D, OR EQUAL 0 0 ® CityofTukwila WALL STOP WITH CONCAVE BUMPER, IVES #WS407GGV, US26D FINISH, OR EQUAL BUILDING DIvISI( KICK -DOWN HOLDER, IVES #FS452 -4, US26D FINISH, OR EQUAL • • • • . •• DOOR SILENCERS (INSTALL 3 PER DOOR), IVES #SR64, GRAY, OR EQUAL 0 0 0 0 0 HINGE PIN DOOR STOP: - SURE LOG (SATIN CHROME) DOOR SCHEDULE SUPPLY INSTALL QTY SY DESCRIPTION USE /TYPE FINISHED SIZE DOOR FRAME LATCH :E FUNCTION LOCK EIRE LABEL DOOR TYPE JAMB TYPE HEAD TYPE JAMB SIZE REMARKS WIDTH FIGHT. THK. MAT. EX EX I CD STOREFRONT ENTRY PAIR 3� -p�� 7' -p" 1_3/4" ALUM. GLASS ALUM. ALUM. D CYLINDER ENTRY --- A EX EX 4 I/2" EXISTING ENTRY DOOR SYSTEM BY LANDLORD, A -OK LOCK INSTALLED BY G.G. LL LL I ® SALES TO HALL 3' -O" 8' -O" I -3/4" W S OO G D PLAM PL-2 MEGA METAL PAINT P2 NONE LEVER PASSAGE - -- D B B 7 1/4" TENANT G.G. TO LAMINATE DOOR WITH WHITE PLASTIG LAMINATE LL LL 2 0 HC TOILET RM DOO 3' -O" 7' -0" I - 3/4" WO S.G. OD PAINT PT -2 M EGA ETAL PT PAINT -2 NONE LEVER PRIVACY - ° 5 B B 4 7/8" DOOR, FRAME AND HARDWARE BY LANDLORD, LL LL I O HALL TO STOCKROOM 3 ' - O" 8' - O" I -3/4" 5 • G • WOOD PAINT PT -2 MEGA METAL PAINT PT -2 NONE LEVER PASSAGE - -- D B B I / DOOR, FRAME AND HARDWARE BY LANDLORD, LL LL I ® OFFICE DOOR 3 ' -O" 7' - O" I -3/4" S.C. WOOD PAINT PT-2 I6GA METAL PAINT PT -2 NONE LEVER ENTRY B B B 4 7/8" DOOR, FRAME AND HARDWARE BY LANDLORD, EX EX I REAR EXIT 3' -O" 7' -O" I -3/4" HOLLOW METAL INSUL PAINT PT -2 MEGA METAL PAINT PT -2 ALUM. PANIC/ BAR ENTRY 10 MIN. G EX EX 7 I/4" EXISTING BUILDING STANDARD SERVICE DOOR, FRAME. PROVIDE ALL REQUIRED HARDWARE. SEE HARDWARE SCHEDULE. COMPLIANCE NOTES FOR DOORS: I. ) DOORS: GENERAL SHALL MEET THE REQUIREMENTS OF THE BUILDING CODE 4 CURRENT EDITION OF THE LIFE SAFETY CODE. 2.) REGARDLESS OF THE OCCUPANT LOAD SERVED, EXIT DOORS SHALL BE OPERABLE FROM THE INSIDE WITHOUT ANY SPECIAL KNOWLEDGE OR EFFORT, MANUALLY OPERATED EDGE OR SURFACE MOUNTED FLUSH BOLTS AND SURFACE BOLTS OR ANY OTHER TYPE OF DEVICE THAT MAY BE USED TO CLOSE OR RESTRAIN THE DOOR OTHER THAN BY OPERATION OF THE LOCKING DEVICE SHALL NOT BE USED. WHERE EXIT DOORS ARE SUED IN PAIRS AND APPROVED AUTOMATIC FLUSH BOLTS ARE USED THE DOOR LEAF HAYING AND AUTOMATIC FLUSH BOLTS SHALL HAVE NO DOOR KNOB OR SURFACE MOUNTED HARDWARE. THE UNLATCHING OF ANY LEAF SHALL NOT REQUIRED MORE THAN ONE OPERATION. 3.) DOOR HARDWARE. HANDLES, PULLS, LATCHES, LOCKS AND OTHER OPERATING DEVICES ON ACCESSIBLE DOORS SHALL HAVE A SHAPE THAT IS EASY TO GRASP WITH ONE HAND AND DOES NOT REQUIRED TIGHT GRASPING, TIGHT PINCHING OR TWISTING OF THE WRIST TO OPERATE LEVER - OPERATED MECHANISMS, PUSH -TYPE MECHANISMS, AND U- SHAPED HANDLES ARE ACCEPTABLE DESIGNS. WHEN SLIDING DOORS ARE FULLY OPEN, OPERATING HARDWARE SHALL BE EXPOSED AND USABLE FROM BOTH SIDES. HARDWARE REQUIRED FOR ACCESSIBLE DOOR PASSAGE SHALL BE MOUNTED NO HIGHER THAN 48" (1220 MM) ABOVE FINISHES FLOOR. 4.) CLEAR WIDTH. DOOR WAYS SHALL HAVE A MINIMUM CLEAR OPENING OF 32 IN. (815 MM) WITH THE DOOR OPEN 10 DEGREES, MEASURED BETWEEN THE FACE OF THE DOOR AND THE OPPOSITE STOP. DOOR TYPES O r EXSTING DOO JAMB AND HEADER (2) 20 GA. MTL. STUDS (TYP. JAMBS) 2 X FRT WOO BUCK (TYP. JAMBS) JAMB ANCHOR TYPE A PAIR OF 3' -O" X 7' -0", ALUMINUM / TEMPERED GLASS ENTRY DOORS JAMB AND HEAD TYPES 7 1/4" OR 4 1/8" HEAD TYPE "B" EXISTING ALUMINUM /TEMPERED GLASS ENTRY DOOR. PUSH PULL SETS 6" OR 3 5/8" STEEL STUD WALL W/ 5/8" TYPE "X" GYP. GYP. BD. EACH SIDE 16 GA. PREFINISHED METAL FRAME, STOP, 4 CASING. DOOR 6" OR 3 5/8" STEEL STUD WALL W/ 5/8" TYPE "X" GYP. BD. EACH SIDE JAMB TYPE "B" DOOR JAMB ANCHOR 16 GA. PREFIN!SHED METAL FRAME, STOP, 4 CASING. 2 X FRT WOOD BUCK (TYP. ® JAMBS) (2) 20 GA. MTL. STUDS (TYP. @ JAMBS) PT -2 METAL FRAME SOLID GORE WOOD DOOR SEE SGHED. FOR FINISH. 2 4 " BRUSHED STAINLESS LEVER SET. SEE HARDWARE SGHED. N 8" X 34" BRUSHED STAINLESS STEEL KICK TYPE B 3' -0" x 7' -o I 3/4" SOLID GORE WOOD FLUSH DOOR 5.) MANEUVERING CLEARANCES AT DOORS. FLOOR WITHIN THE REQUIRED CLEARANCES SHALL BE LEVEL AND CLEAR. 6.) THRESHOLDS AT DOORWAYS. THRESHOLDS AT DOORWAYS SHALL NOT EXCEED 3/4 IN. (11 MM) IN HEIGHT FOR EXTERIOR SLIDING DOORS OR 1/2 IN. (15MM) FOR OTHER TYPES OF DOORS. RAISED THRESHOLDS AND FLOOR LEVEL CHANGES AT ACCESSIBLE DOORWAYS SHALL BE BEVELED WITH A SLOPE NO GREATER THAN 1:2. - 1.) DOOR CLOSURES, IF A DOOR HAS A CLOSER, THEN THE SWEEP PERIOD OF THE CLOSER SHALL BE ADJUSTED SO THAT FROM AN OPEN POSITION OF 10 DEGREES, THE DOOR WILL TAKE AT LEAST 3 SECONDS TO MOVE TO A POINT 3 IN. (15 MM) FROM THE LATCH, MEASURED TO THE LEADING EDGE OF THE DOOR. 8.) DOOR OPENING FORGES. THE MAXIMUM FORGE FOR PUSHING OR PULLING OPEN A DOOR SHALL BE AS FOLLOWS: (I) FIRE DOORS SHALL HAVE THE MINIMUM OPENING FORGE ALLOWABLE BY THE APPROPRIATE ADMINISTRATIVE AUTHORITY. (2) OTHER DOORS. (a) EXTERIOR HINGED DOORS: (RESERVED). (b) INTERIOR HINGED DOORS: 5 Ibf (22.2N). (C) SLIDING OR FOLDING DOORS: 5 Ibf (22.2N). THESE FORGES DO NOT APPLY TO THE FORGE REQUIRED TO RETRACT LATCH BOLTS OR DISENGAGE OTHER DEVICES THAT MAY HOLD THE DOOR IN A CLOSED POSITION. METAL FRAME PEEP HOLE VIEWER PANIC DEVICE HOLLOW METAL DOOR TYPE C 3' -O" X 7' -0 13/4" HOLLOW METAL FLUSH DOOR CLOSER PT -2 8" X 34" BRUSHED STAINLESS STEEL KICK O c0 CLOSER PT -2 f -" PL -2 TYPE D 3 ' -O" X S' -O" 13/4" SOLID GORE WOOD FLUSH DOOR METAL FRAME SOLID GORE WOOD DOOR SEE SGHED. FOR FINISH. BRUSHED STAINLESS LEVER SET. SEE HARDWARE SGHED. 8" X 34" BRUSHED STAINLESS STEEL KICK GENERAL ACCESSIBILITY AND LIFE SAFETY: I. EVERY EXIT DOOR SHALL BE OPENABLE FROM THE INSIDE WITHOUT THE USE OF A 1. PROVIDE EXIT SIGNS AND DIRECTIONAL EXIT SIGNS AT LOCATIONS SHOWN KEY, TOOL, OR SPECIAL KNOWLEDGE OR EFFORT. SPECIAL LOCKING DEVICES SHALL BE OF AN APPROVED TYPE. 2. EXIT DOORS (INCLUDING EXISTING DOORS) SHALL NOT BE LESS THAN 36" IN WIDTH 8. AND NOT LESS THAN 6' -8" IN HEIGHT. PROJECTIONS INCLUDING PANIC HARDWARE, SHALL NOT REDUCE THE OPENINGS TO LESS THAN 32" IN CLEAR WIDTH. 3. HEIGHT OF THRESHOLDS AT EXIT DOORS SHALL BE 1/2" MAXIMUM. 4. CARPET PILE HEIGHT SHALL BE 1/2" MAXIMUM. 5. AISLES LEADING TO REQUIRED EXITS SHALL HAVE A MINIMUM WIDTH OF 44 ". S. GLASS DOORS, ADJACENT PANELS, AND ALL GLAZED OPENINGS WITHIN 24" OF ADJACENT FLOORS SHALL BE TEMPERED GLASS. GENERAL CONTRACTORS RESPONSIBILITIES: I. THE CONTRACTOR 15 RESPONSIBLE FOR ALL COORDINATION BETWEEN SUBCONTRACTORS BASED ON ENTIRE SET OF DOCUMENTS. NO EXTRA COMPENSATION WILL BE GIVEN TO A BIDDER OR SUPPLIER WHO HAS BID FROM AN INCOMPLETE SET OF CONSTRUCTION DOCUMENTS. IN CASE OF INCONSISTENCIES OR DISCREPANCIES BETWEEN DRAWINGS THE MOST STRINGENT NOTE OR CONDITION SHALL APPLY AND THE CONTRACTOR SHALL NOTIFY THE OWNER AND THE ARCHITECT IMMEDIATELY OF SUCH DISCREPANCIES. 2. IT 15 THE RESPONSIBILITY OF THE CONTRACTOR TO FIELD VERIFY EXISTING SITE CONDITIONS AND DIMENSIONS PRIOR TO STARTING CONSTRUCTION. CONDITIONS SHOWN ON THESE DOCUMENTS ARE BASED ON INFORMATION SUPPLIED BY THE LANDLORD. 3. THE CONTRACTOR IS RESPONSIBLE FOR MAINTAINING A CURRENT SET OF CONSTRUCTION DRAWINGS ON SITE DURING CONSTRUCTION. THE CONTRACTOR SHALL INDICATE ON THESE PLANS ALL APPROVED CHANGES TO THE WORK. THIS SET OF DRAWINGS SHALL BE TURNED OVER TO THE OWNER WHEN THE PROJECT 15 COMPLETE. 4. IF ANY ERRORS, DISCREPANCIES OR OMISSIONS APPEAR ON THESE DRAWINGS, SPECIFICATIONS OR OTHER CONTRACT DOCUMENTS, THE CONTRACTOR SHALL CONTACT THE OWNER AND THE ARCHITECT. 5. NO MATERIAL SUBSTITUTIONS WILL BE ALLOWED UNLESS SUBMITTED IN WRITING TO THE OWNER FOR APPROVAL IN WRITING. NOTIFICATION MUST BE SUBMITTED WITHIN 10 WORKING DAYS OF CONTRACT AWARD. 6. THE CONTRACTOR IS REQUIRED TO PROVIDE A LIST OF ALL SUBCONTRACTORS TO BE USED AND SUBMIT THIS LIST TO THE OWNER WITHIN 10 WORKING DAYS OF CONTRACT AWARD. PROVIDE A COPY OF THIS LIST TO THE STORE MANAGER. 1. REFER TO TENANT / CONTRACTOR RESPONSIBILITY SCHEDULE FOR WORK RESPONSIBILITY. THIS SCHEDULE HAS PRECEDENCE OVER DRAWINGS AND SPECIFICATIONS. 8. THE CONTRACTOR 15 RESPONSIBLE FOR CHECKING IN AND VERIFYING ALL SHIPMENTS OF OWNER SUPPLIED MATERIALS. THIS INCLUDES VERIFYING PACKING LISTS AGAINST ORDER FORMS AND BILLS OF LADING. IF THIS 15 NOT DONE THE CONTRACTOR WILL BEAR THE COST OF ANY EXPEDITED FREIGHT CHARGES TO MEET THE CONSTRUCTION SCHEDULE. CONTRACTOR IS RESPONSIBLE FOR FILING DAMAGE REPORTS AND MUST MAINTAIN PACKING MATERIALS FOR SHIPMENT OF DAMAGED ITEMS. q. THE CONTRACTOR SHALL KEEP ALL HANDBOOKS AND PAPERWORK INCLUDING ALL PACKING SLIPS AND BILLS OF LADING IN A MARKED ENVELOPE. THIS ENVELOPE 15 TO BE TURNED OVER TO THE STORE MANAGEMENT. 10. THE CONTRACTOR SHALL DELIVER TO THE OWNER A COPY OF THE CERTIFICATE OF OCCUPANCY, UNCONDITIONAL LIEN WAIVERS, WARRANTIES, GUARANTEES AND EQUIPMENT OPERATION MANUALS. THE ORIGINAL CERTIFICATE OF OCCUPANCY TO BE FRAMED AND MOUNTED AT STORE MANAGER'S DESK. II. THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE CLEAN UP OF ALL TRADES. 12. THESE DRAWINGS ARE NOT TO BE SCALED. 13. THESE DRAWINGS ARE NOT TO BE ALTERED IN ANY WAY WITHOUT WRITTEN AUTHORIZATION THE OWNER AND OWNERS ARCHITECT. 14. MAINTAIN EGRESS AT ALL TIMES DURING STORE OPERATION. 15. COORDINATE CONSTRUCTION TIME AND NOISE REQUIREMENTS WITH LANDLORD. 16. THE CONTRACTOR SHALL PROVIDE PROTECTIVE COVERING OF ALL EQUIPMENT, MERCHANDISE, CARPET, ETC. 1. ON THE FLOOR PLAN. EXIT SIGNS SHALL HAVE A MAXIMUM 6" HIGH BY 3/4" STROKE BLOCK LE I I I=RS ON A CONTRASTING BACKGROUND. EXIT SIGNS SHALL BE INTERNALLY ILLUMINATED BY TWO ELECTRIC LAMPS OR SHALL BE OF APPROVED SELF - LUMINOUS TYPE. IF TWO LAMPS ARE USED, POWER SUPPLY TO ONE OF THE LAMPS SHALL BE PROVIDED BY THE PREMISES WIRING SYSTEM. POWER SUPPLY TO THE OTHER LAMP SHALL BE FROM STORAGE BATTERIES. THE SYSTEM SHALL BE INSTALLED IN ACGORDANCE WITH THE NATIONAL ELEGTRIG CODE. EMERGENCY LIGHTING SHALL BE PROVIDED FROM AN EMERGENCY POWER SYSTEM AND SHALL PROVIDE A VALUE OF ONE FOOT CANDLE AT FLOOR LEVEL. 17. UPON COMPLETION OF CONSTRUCTION, IT WILL BE THE RESPONSIBILITY OF THE CONTRACTOR TO GLEAN ALL FINISH SURFACES/FIXTURES PER MANUFACTURER'S INSTRUCTIONS AND TO EMPLOY THE SERVICES OF A PROFESSIONAL GLEANING COMPANY TO ASSURE THE TENANT AN ABSOLUTELY GLEAN STORE. FINAL CLEANING 15 TO BE PERFORMED NO MORE THAN ONE DAY PRIOR TO MERCHANDISE ARRIVAL. IF AN UNTIDY STORE IS TURNED OVER, THE TENANT RESERVES THE RIGHT TO EMPLOY SIMILAR GLEANING SERVICES AND TO DEDUCT THE COST PLUS 10% FROM THE BALANCE OF THE CONTRACTORS CONTRACT SUM. IS. COORDINATE ALL ACTIVITIES WITH MALL MANAGEMENT PRIOR TO START OF CONSTRUCTION. INTERRUPTION OF SERVICES TO THE SHOPPING CENTER / MALL OR OTHER TENANTS SHALL BE HELD TO A MINIMUM. COORDINATE SUCH INTERRUPTIONS WITH THE LANDLORD. EXISTING SERVICES WHICH ARE IN ANY WAY AFFECTED BY THE PERFORMANCE OF THIS WORK SHALL BE PROTECTED AND MAINTAINED. THIS INCLUDES UTILITY SERVICES FOR THE SHOPPING CENTER / MALL OR OTHER TENANTS THAT ORIGINATE IN OR PASS THROUGH THE SAID SPACE Iq. G.G. TO PROVIDE AND COORDINATE INSTALLATION OF TEMPORARY BARRICADES, AND DUST AS REQUIRED BY THE BUILDING OWNER. 20. INSTALL TEMPORARY ENTRANCE, DOORS FRAMES HOW. WHERE REQUIRED BY BUILDING OWNER. 21. ALL CONSTRUCTION TO CONFORM TO ALL APPLICABLE CODES AND ALL APPLICABLE ORDINANCES. 22. ALL DIMENSIONS ARE TO FINISH FACE OF WALL, UNLESS OTHERWISE NOTED. 23. ALL WOOD CONSTRUCTION ASSOCIATED WITH THIS WORK SHALL BE FIRE RESISTANT TREATED (FRT). ALL NEW FRAMING AT STOREFRONT AND ABOVE CEILING SHALL BE NON - COMBUSTIBLE. 24. CONTRACTOR SHALL COORDINATE GUTTING OF SLAB (IF REQUIRED) WITH MALL OPERATIONS MANAGER PRIOR TO BEGINNING WORK. 25. CONTRACTOR SHALL BE RESPONSIBLE FOR COORDINATING ALL THEIR WORK AND THE WORK OF THEIR SUBCONTRACTORS WITH STRUCTURE AND SHELL BUILDING ELEMENTS. CONTRACTOR SHALL IMMEDIATELY NOTIFY THE OWNER AND ARCHITECT OF ANY SIGNIFICANT DISCREPANCIES OWNERS DRAWINGS AND BUILDING SHELL. 26. CONTRACTOR TO PROVIDE FIRE EXTINGUISHERS AS REQUIRED. PROVIDE BLOCKING AS REQUIRED. VERIFY QUANTITY AND LOCATION WITH LOCAL OFFICIALS. 21. CONTRACTOR WILL RELOCATE / MODIFY EXISTING SPRINKLERS AND ADD NEW SPRINKLERS AS REQUIRED. COORDINATE WITH MALL MANAGEMENT PRIOR TO STARTING THIS WORK 25. CONTRACTOR SHALL BE RESPONSIBLE FOR GUTTING OF STUDS, INSERTS AND BLOCKING. 2q. CONTRACTOR TO PROVIDE FULL FLOOR PREP AS REQUIRED TO RECEIVE NEW FINISHES. ALL MAJOR FLOOR PREP. MUST BE BROUGHT TO THE ATTENTION OF THE BUILDING MANAGER PRIOR TO THE COMMENCEMENT OF SAID INORK. AS REQUIRED. 30. POS MATERIALS AND INSTALLATION BY TENANT. 31. TELEPHONE SERVICE TO PHONE PANEL BY TENANT ALL OTHER INORK REQUIRED BY G.G. (I.E. PHONE JACKS, EGT.) 32. CONTRACTOR SHALL BE RESPONSIBLE FOR COORDINATION OF ALL CEILING INORK WITH CEILING PLAN AND ELECTRICAL LIGHTING PLAN. 33. ELECTRICAL CONTRACTOR SHALL BE RESPONSIBLE FOR COORDINATION OF LIGHTING WITH CEILING PLAN AND ELECTRICAL LIGHTING PLAN. 34. ELECTRICAL CONTRACTOR SHALL BE RESPONSIBLE FOR PROVIDING AND INSTALLING ALL LIGHT FIXTURE SUPPORTS. 35. THE GENERAL CONTRACTOR AND FIXTURE CONTRACTOR SHALL COORDINATE WITH THE INSTALLATION OF ALL FIXTURE CONTRACTOR SUPPLIED ITEMS. 36. THE G.G. WILL BE RESPONSIBLE FOR THE COORDINATION, UNLOADING, STORING SECURITY, AND PLACEMENT OF ALL OWNER SUPPLIED ITEMS. E IV DATE: JOB NO: DRAWN: CHECKED: 3405 11/15/09 09 -066 STAFF KB KENNETH L. BUTTS ARCHITECT AIA 124 STAGECOACH ROAD BELL CANYON, CA 91307 (818) 999 -4272 REGISTERED ITECT i ENN L. BUTTS STATE OF WASHINGTON ( AD DTz ri D• E • S• I • G• N 225 OAKLAND RAOD, SUI1E 105 ?EL: (860)183 -5610 SOIIIN WINDSOR, CT 06014 FAX: (860)183-5680 DEC 0 8 2009 W �- cc a vZ C ,0 LU CC 0 d- W = < d- r Z D WOQ O U ( J z I 0 U O D CO - F- 'IV- ISSUE DATE 'Cr- ISSUE DATE ISSUE DATE L CD 141a co V STORE NUMBER #TBD REVISIONS 'A'- ISSUE: LANDLORD COMMENTS DATE: I2/1/09 RECEIVED CITY OF TUKWILA DEC 2 2 2009 PERMIT CENTER SHEET TITLE DOOR SCHEDULE DOOR TYPES DOOR HARDWARE SCALE NOTED SHEET NUMBER C1.2 TOTAL AREA 4,000 Sq. Ft. WALL TYPE SCHEDULE: DETAIL SYM DESCRIPTION NONE A) EXISTING EXTERIOR WALLS: • . ' . A. EXISTING EXTERIOR MASONRY WALLS FULL HEIGHT. EXTERIOR E.I.F.S., INTERIOR FULL HEIGHT METAL FURRING BATT INSULATION AND GYP. BD. NONE A.) EXISTIN 3HR TENANT DEMISING WALL: EXSITING FULL HEIGHT METAL STUDS 16" O.G., FIBERGLASS BATT INSULATION, AND (3) LAYERS OF 5/8" TYPE "X" GYP. BD. FULL HEIGHT TO UNDERSIDE OF ROOF DECK. EQUAL TO 3HR UL DESIGN U41q. at ' ' -- ' A DECK HEIGHT AT REAR 22' -O" A.F.F. fit 0 EXISTING GAS METER BANK O A • • EX 28" BAR JOIST EX 28" BAR JOIST EX 28" BAR JOIST EXISTING DOMESTIC WATERLINE ABOVE EX 28" BAR JOIST 4 1 EX 28" BAR JOIST EX 28" BAR JOIST EX 28" BAR JOIST 3 II EXISTING REAR EXTERIOR WALL GOMPLETELY FURRED WITH GYP. BD. TO THE DECK EXISTING SLAB LEAVE OUT EXISTING 69 GAS LINE ABOVE 4 1 EXISTING 3HR RATED COLUMN AND TRUSS GIRDER ENCLOSURE LEASE OUTLINE STRUCTURE PLAN SCALE: 3/16T =1' -0" - 14' -IOi" +/- 8' -O" LEASE DIMENSION SCALE: 3/16" =1' -0' 2 EX 28" BAR JOIST EX 28" BAR JOIST EX 28" BAR JOIST EX 28" BAR JOIST EX 28" BAR JOIST EX 28" BAR JOIST EX 28" BAR JOIST EXISTING 3HR RATED DEMISING WALL TENANT SPACE NO. 144 4,000 SO/FT EXISTING CONCRETE SLAB THROUGH -OUT I — PROPOSED DEMISING WALL DEMISING WALL LEASE OUTLINE FLOOR PLAN EXISTING FRONT EXTERIOR WALL COMPLETELY FURRED WITH GYP. BD. TO THE DECK / / / / / / / / / / / / 14‘ EX 14 BAR JOI \ \ / // i EX 14" BAR JOIST EX 14" BAR JOIST EX 14" BAR JOIST EX 14" BAR JOIST DECK HEIGHT AT FRONT 23' -6" A.F.F. \ L4_1 / GENERAL STRUCTURE NOTES: GENERAL 2 4 LEASE PLAN NOTES: GENERAL: THIS TENANT SPACE IS A GOLD SHELL, THE FOLLOW KEYED NOTES DESCRIBES THE EXISTING CONDITIONS. STOREFRONT: INTERIOR: 2 3 1 41 5 1 61 THIS SPACE 15 OPEN TO STRUCTURE DELIVERED TO TENANT. LANDLORD DESIGNATED ROOF TOP EQUIPMENT LOCATIONS. (3) EXISTNG J -BOXES MOUNTED TO BOTTOM OF BAR JOIST FOR FUTURE TENANT SERVICES, ELECTRICAL, TEL, FIRE ALARM. EXISTING SPRINKLER BRANCH PIPING ABOVE WITH HEADS TURNED UP TO THE DECK (TYP.). D09 2b9 EXISTING STOREFRONT ALUMINUM FRAMING GLASS AND ENTRY DOORS. EXISTING CONCRETE SLAB FLAT AND SMOOTH READY TO ACCEPT NEW TENANT FINISHES. SLAB LEAVE OUT LANDLORD G.G. TO COMPLETE THE SLAB AND IN -FILL WITH VAPOR BARRIER, WELDED WIRE FABRIGK AND CONCRETE. EXISTING 3HR RATED TENANT DEMISING WALL EQUAL TO UL 4HR DESIGN NUMBER U4Iq. EXISTING REAR EXTERIOR WALL CONSTRUCTION WITH BATT INSULATION AND GYP ED. FULL HEIGHT TO UNDERSIDE OF DECK. EXISTING REAR SERVICE DOORS WITH BUILDING STANDARD HARDWARE. REVIEWED FOR CODE COMPLIANCE APPROVED JAN 0 6 2010 City of Tukwila BUILDING DIVIRIfMI RECEIVED CITY OF TUKWILA DEC 2 2 2009 PERMIT CENTER DATE: JOB NO: DRAWN: CHECKED: 3405 I (/1/09 09-06 STAFF KB KENNETH L. BUTTS ARCHITECT AIA 124 STAGECOACH ROAD BELL CANYON, CA 91307 (818) 999 -4272 REGISTERED CL CT KENNET Ft L. BUTTS STATE OF WASHINGTON (ADDTr1 D• E • S• I • G• N 225 OAKLAND RAM, MBE 105 TEL: (060) 183 -5610 801114 weOR CT 06014 FAX: (860)183-5680 DEC 0 8 2009 Y W CC cc W 00 r � ^ Z � CO W V / CCU d' I I < t z � . 2 I— O C) ILO as O CO I—Co STORE NUMBER %TBD REVISIONS 'A'- ISSUE: LANDLORD COMMENTS DATE: 12/1/09 'B' -ISSUE DATE 'C'- ISSUE DATE 'D'- ISSUE DATE SHEET TITLE N - a C to N :a SCALE 3/16 " = 1 - 0 " SHEET NUMBER A0.1 LEASE OUTLINE FLOOR AND STRUCTURE PLAN v WALL TYPE SCHEDULE: DETAIL SYM DESCRIPTION NONE A ) A) EXISTING EXTERIOR WALLS: 4 EXISTING EXTERIOR MASONRY WALLS FULL HEIGHT. EXTERIOR E.I.F.S., INTERIOR FULL HEIGHT METAL FURRING BATT INSULATION AND GYP. BD. I/A4.1 A.) EXISTING 3HR TENANT DEMISING WALL: EXSITING FULL HEIGHT METAL STUDS 0 16" O.G., FIBERGLASS BATT INSULATION, AND (3) LAYERS OF 5/8" TYPE "X" GYP. BD. FULL HEIGHT TO UNDERSIDE OF ROOF DECK. EQUAL TO 3HR UL DESIGN U41c1. 0 � :.... 2/A4.1 A) A.) NEW DEMISING WALL: IHR RATED 6" X 2OGA METAL STUDS g 16" O.G. , FIBERGLASS SOUND BATT INSULATION WITH 5/8 "X" TYPE X GYP. BD. FULL HEIGHT TO UNDERSIDE OF ROOF DECK. EQUAL TO UL DESIGN U -465. 3/A4.I 4/A4.1 1/A4.1 /A4.1 7 A) A) INTERIOR PARTITIONS: (SMOKE PARTITON) ' ' ' ' 6" X 2OGA METAL STUDS 0 16" O.G. WITH 5/8" TYPE "X" GYP. BD. FULL HEIGHT TO UNDERSIDE OF DECK. I/A4.2 A , ) A.) INTERIOR PARTITION: 1�������11 6 X 2OGA METAL STUDS 0 16 O.G. W/ 5/8 �� TYPE MR GYP. BD. TO 6 �� ABOVE FINISHED CEILING. SEE SPECIFIC DETAILS FOR BRACING. 6/A4.1 a /A4.1 2/A4.2 P `• ) A) INTERIOR PARTITIONS: 3 5/8" X 20GA METAL STUDS 0 16" O.G. W 5/8" TYPE "X" GYP. BD. TO 6" ABOVE FINISHED CEILING. USE TYPE "MR" GYP. P. IN ALL WET AREA'S. SEE SPECIFIC DETAILS FOR BRACING. 10 OFFICE 104 73 SQ Fi' =2X STOCK ROOM 105 396 SQ FT= 10Z HALL 101 108 SQ /FT =4Z _ mma 133831 BSI MI 843931 MS OM C3301 EMS MS IMO ISES MS RES BM EISS MS MS KM ISM IIESS 15/331 HC TOILET WOMENS ROOM 102 58 SQ /FT =17. IN SLAB CONDUITS BY L.L. EXISTING 3HR RATED COLUMN ENCLOSURE SCALE: 1/4' - T-0' SALES AREA 100 3301 SQ /FT= 82% CONSTRUCTION PLAN OUTLINE OF GASHWRAP °N- 0 i HC TOILET MENS ROOM 103 64 SQ /FT -1% _ 7' -O" 1' -4" CONSTRUCTION PLAN NOTES: LANDLORD WORK EXISTING ALUMINUM AND GLASS STOREFRONT AND ENTRY DOORS TO REMAIN. SALES FLOOR: 100 2 3 4 5 6 7 a1 LEASE DIMENSION EXISTING 3HR RATED TENANT DEMISING WALL, LANDLORD TO PREP FOR PAINT FINISH. PROVIDE NEW IHR RATED TENANT DEMISING WALL, LANDLORD TO PREP FOR PAINT FINISH. LANDLORD TO TRENCH CONCRETE SLAB FOR IN SLAB CASH DESK CONDUITS. SEE ELECTRICAL DRAWINGS FOR REQUIRED CONDUITS. PATCH AND REPAIR CONCRETE FLOOR AS REQUIRED. LANDLORD SHALL PREPARE THE CONCRETE SLAB READY FOR NEW TENANT FLOOR FINISH, THE SLAB SHALL BE LEVEL AND SMOOTH READY FOR TENANT'S FLOOR FINISH INSTALLATION. LANDLORD TO PROVIDE INSTALL SALES STOCK PARTITION ALONG WITH DOOR, FRAME AND HARDWARE, SEE DOOR SCHEDULE. LANDLORD TO PROVIDE COLUMN ENCLOSURES TO MINIMUM DIMENSIONS TO 6" ABOVE FINISHED CEILING. LANDLORD TO PROVIDE METAL STUD AND GYP. BD. CORNER FILLERS TO DIMENSIONS INDICATED TO 6" ABOVE FINISHED CEILING. 57' -a LAN ORTH HALL: 101 a TOILET ROOM: 102 AND 103 Q I I 12 LANDLORD TO PROVIDE NEW HALL PARTITIONS COMPLETE WITH DOOR, FRAME AND HARDWARE AS SHOWN. LANDLORD TO PROVIDE HANDICAPPED COMPLIANT TOILET ROOMS, COMPLETE WITH PARTITIONS, DOORS, PLUMBING FIXTURES. FINISHES AND ACCESSORIES. SEE DETAILS SHEET A33 OFFICE: 104 FcTi LANDLORD TO PROVIDE NEW OFFICE PARTITIONS COMPLETE WITH , DOOR FRAME, AND HARDWARE. IANDLORD TO COORDINATE WITH ELECTRICAL DRAWINGS AND PROVIDE REQUIRED ELECTRICAL DEVICES, TEL/ FAX DEVICE AS REQUIRED. SEE SHEET A3.4 STOCKROOM: 105 LOCATION FOR ELECRIGAL SERVICE, EQUIPMENT AND TELEPHONE. PROVIDE BACK BOARD FOR TEL. AND SECURITY SYSTEM INSTALLATION. SEE ELECTRICAL DRAWINGS FOR COMPLETE INFORMATION. LANDLORD TO PROVIDE AND INSTALL MOP SERVICE SINK AND HOT WATER HEATER AS SHOWN. SEE PLUMBING DRAWINGS. 1 eie o e ® 13 141 151 S S S S • COORDINATE WITH ELECTRICAL DRAWINGS AND STOCKROOM ELEVATIONS FOR THE BREAK COUNTER REQUIRED ELECTRICAL DEVICES AND SPECIFIC INSTALLATION LOCATIONS. SEE SHEET A3.4 FOR DETAILS. PROVIDE COMPLETE IN -FILL FOR SLAB LEAVEOUT, INCLUDING VAPOR BARRIER, WELDED WIRE MESH AND CONCRETE, FIELD VERIFY EXACT EXTENTS. REAR SERVICE DOORS ARE EXISTING TO REMAIN. S \ \ e r 7 V d N N /A\ ALL 1NORK BY LANDLORD UNDER LANDLORD PERMIT. S � ■ 7 • • • S S S REVIEWED FOR DE COMPLIANCE APPROVED JAN 0 6 2010 City of Tukwila ILDING DIVISION RECEIVED CITY OF TUKINILA DEC 22 2110q PERMIT CENTER DATE: 11/15/09 JOB NO: 09 -0&& DRAWN: STAFF CHECKED: KB 340 KENNETH L. BUTTS ARCHITECT AIA 124 STAGECOACH ROAD BELL CANYON, CA 91307 (818) 999 -4272 REGISTERED C ECT KENNETH 1. BUTTS STATE OF WASHINGTON (A D • E • S• I • G• N 225 OAKLAND RAOD, SUITE 105 TEL: (860)183-5610 5011114UNC5OR CT 06014 FAX (860)183 -5680 DEC 0 ri Q W vzr COWw, <71- D • NOQz w e H 0 : U Ne - 0 4 1• 1 L I :1 V STORE NUMBER SHEET TITLE %TBD REVISIONS 'A'- ISSUE: LANDLORD COMMENTS DATE: 12/7/09 'B'- ISSUE DATE 'C'- ISSUE DATE ISSUE DATE CONSTRUCTION PLAN SCALE 1/4' -1-0' SHEET NUMBER All FINISH SCHEDULE �����7 -./- PAINT SYMBOL LOGATION TYPE STYLE /DESCRIPTION MFG. MFG. # REMARKS SALES FLOOR, OFFICE PAINT EXTRA WHITE PAINT: SATIN LATEX SHEEN SUPERPAINT SERIES SHERWIN WILLIAMS 7006 PROVIDE PRIMER AND (2) FINISH GOATS OF PAINT BY LANDLORD, "LEVEL 3 FINISH" PTI HALL, STOCK AND TOILET ROOMS PAINT EXTRA WHITE PAINT: SEMI GLOSS SHEEN SUPERPAINT SERIES SHERWIN WILLIAMS 1006 PROVIDE PRIMER AND (2) FINISH GOATS OF PAINT. UNLESS NOTED OTHERWISE BY LANDLORD, "LEVEL 3 FINISH" PT2 FLOOR FINISHES MARK LOCATION TYPE COLOR / STYLE/ DESGRIPTION MFG. MFG. # R - - SALES AREA SOLID VINYL VINYL WOOD FLOORING: MONTANAN PLANKS, SIZE 7.24" x 3 X I/8" EARTH WERKS &MP aal6 SUPPLIED AND INSTALLED BY TENANT FGI SALES AREA SOLID VINYL VINYL WOOD FLOORING: MONTANAN PLANKS, SIZE 7.24" x 3"7.34" X I/8" W EARTH ERKS GMP Ga14 SUPPLIED AND INSTALLED BY TENANT FG2 TOILET ROOM SHEET VINYL SHEET VINYL - SAND BAR ARMSTRONG 88053 SUPPLIED AND INSTALL BY LANDLORD, COVE UP THE WALL 6", FG3 HALL, OFFICE AND STOCK VINYL TILE SAND DUNE 12" X 12" X I/8" VCT AZROGK V8T3 SUPPLIED AND INSTALL BY LANDLORD FG4 FG5 STOREFRONT ENTRY MAT REGESSED WALK OFF MAT GARTERS T.B.D. SUPPLIED AND INSTALLED BY TENANT WALL BASE SYMBOL LOCATION TYPE STYLE /DESCRIPTION MFG. MFG. # REMARKS SALES AREA WOOD 1/2 X 4" WOOD BASE WITH 1/2" GUATER ROUND POPLAR MILLSHOP SHOP PRIME AND PAINTED WHITE PT -2 B -I HALL, OFF IGE AND STOCK SOLID VINYL 6" HIGH COVE BASE (GANVAS) JOHNSONITE 4411 SUPPLIED AND INSTALLED BY TENANT B -2 B -3 GASHDESK GOVE BASE 4" HIGH BASE JOHNSONITE BL T SUPPLIED AND INSTALLED BY TENANT FRP WAINSCOT SYMBOL LOCATION TYPE STYLE / DESGRIPTION MFG. MFG. # REMARKS FRP -I RESTROOM, SEE ELEVATION FRP FRP PANELS, WHITE MARLITE P -I00 BY LANDLORD, PROVIDE ALL TRIM $ ACCESSORIES PLASTIC LAMINATE SYMBOL LOCATION TYPE STYLE /DESCRIPTION MFG. MFG. # REMARKS PL -I SALES STOCK DOOR/ SALES SIDE PLASTIC LAMINATE DESIGNER WHITE IN ILSONART 0354 -60 APPLY TO SALES 5 1 DE OF STOCK DOOR FULL HEIGHT BY G.G. CORNER GUARDS LOCATION TYPE STYLE /DESCRIPTION MFG. MFG. No. REMARKS ALL NON SALES AREA OUTSIDE CORNERS METAL I I/8" X I I/8" BRUSHED ALUMINUM CORNER GUARDS CORNER PROTECTOR MXI OR EQUAL HCPI48.B SUPPLIED AND INSTALLED BY G.G. INSTALL ON ALL OUTSIDE NONE SALES AREA CORNERS. I4' -7" 6.1 HC TOILET WOMENS ROOM 102 SO/FT •1% 14'-10" LEASE DIMENSION FLOOR FINISH PLAN SCALE: 1/4' - T-0' 5 -a" PLAN NORTH "LEVEL 3" NOTE AD p FLOOR FINISH NOTES: LANDLORD WORK SALES FLOOR: 100 1.1 LANDLORD TO PAINT SALES AREA (PTI) PER TENANT DRAWINGS. SEE FINISH SCHEDULE FOR PAINT SPEC, HALL: 101 2.1 LANDLORD TO PAINT HALL (PT2) AND INSTALL (FRP) PER TENANT DRAWINGS. SEE FINISH SCHEDULE FOR SPEC. SEE ELEV SHEET A3.2 LANDLORD TO INSTALL THE VGT IN THE HALL, SEE PLAN LANDLORD TO INSTALL THE VINYL COVE BASE THROUGHOUT THE HALL, D SEE PLAN. H.C. TOILET ROOMS: 102 AND 103 3.1 4.1 5.1 6.1 LANDLORD TO PAINT TOILET ROOMS (PT2) AND INSTALL (FRP) PER TENANT DRAWINGS. SEE FINISH SCHEDULE FOR SPEC. SEE ELEV SHEET A3.3. LANDLORD TO INSTALL THE SHEET VINYL WITH INTEGRATED 6" BASE THROUGHOUT THE TOILET ROOM AREA, SEE PLAN. OFFICE: 104 LANDLORD TO PAINT OFFICE (PT2) PER TENANT DRAWINGS. SEE FINISH SCHEDULE FOR PAINT SPEC. LANDLORD TO INSTALL THE VGT IN THE OFFICE, SEE PLAN. 1.1 8.1 a.l LANDLORD TO INSTALL THE VINYL COVE BASE IN THE OFFICE, SEE PLAN. STOCKROOM: 105 10.1 I I.1 12.1 LANDLORD TO PAINT STOCKROOM (PT2) PER TENANT DRAWINGS. SEE FINISH SCHEDULE FOR PAINT SPEC. LANDLORD TO INSTALL THE VGT IN THE STOCK ROOM, SEE PLAN. LANDLORD TO INSTALL THE VINYL COVE BASE IN THE STOCK ROOM, SEE PLAN. ALL WORK BY LANDLORD UNDER LANDLORD PERMIT. B.1 ' FLOOR FINISH NOTES: TENANT G.C. WORK SALES FLOOR: 100 2 3 TENANT VENDOR TO INSTALL VINYL WOOD PLANK FLOORING IN SALES AREA AS DIMENSIONED, SEE PLAN TENANT VENDOR TO INSTALL RECESSED ENTRY MATT TENANT G.G. TO INSTALL SUPPLIED BASE THROUGHOUT THE SALES FLOOR AREA. SEE DETAIL #3 THIS SHEET FLOOR FINISH INSTALLATION: GENERAL: A. ALL FLOOR COVERINGS SHALL BE INSTALLED PER MANUFACTURERS STANDARD DETAILS AND SPECIFICATIONS. THE FLOORING CONTRACTOR IS RESPONSIBLE FOR VERIFYING THAT THE CONDITION OF THE BASE FLOOR MEETS THE MANUFACTURES INSTALLATION REQUIREMENTS PRIOR TO THE INSTALLATION OF THE FLOORING MATERIAL, THE FLOORING CONTRACTOR SHALL PERFORM A CALCIUM CHLORIDE TEST IN ACCORDANCE WITH MFG REQUIREMENTS AND ASTM I86a. IF MOISTURE CONTENT OF FLOOR EXCEEDS THE MFG RECOMMENDED ALLOWANCES. THE FLOORING CONTRACTOR SHALL PROVIDE THE RECOMMENDED SURFACE PREPARATION PER THE MFG'S SPECIFICATIONS. D. THE GENERAL CONTRACTOR 15 RESPONSIBLE TO PREPARE THE EXISTING FLOOR FOR THE PROPER INSTALLATION OF THE FLOOR COVERING MATERIALS INDICATED ON THE PLAN. CONSULT MANUFACTURES SPECIFICATIONS FOR SURFACE PREPARATION REQUIREMENTS FOR EACH FINISH LISTED IN THE FINISH SCHEDULE. E. FLOORING SHALL BE NON -SLIP IN ACCORDANCE WITH THE ILLINOIS ACCESSIBILITY CODE, SECTION 400.310 (A) 5. CORRIDOR WIDTH SHALL COMPLY WITH IBC SECTION 1004.3.2.2. B. G. z 0 z I w w N r- _�� 1118.1 • a.1 OFFICE 104 73 SOIFT °27. 5.116.1 • ■I : . - • EME11111111111.girn mmmeerrATAIIII II 1 • Ir NW 1111111ANCI 1 �IIIII / r r M �I J I 1 19. ANI A <.\ ■ J mdzimm i ‘AVIIIIIMMIIIIIIIIIIM I. in III, - � '�',-_� 1 AM& 40‘ Illr" 4& _IIIIIIII INIAIMIIIIIMM AIMII\ AIMMMIIMIP Mr AMIN ur ,�► ♦ AIM/ 1111141111111111111W !raw r te� ' Mai 1 M 1111111 MIND2 mommumwdo HC TOILET MENS ROOM 103 64 SQ /FT =1% ■ 1 1 1 - PT -2 FRPI FG3 tt 58 PT -2 FRPI FG3 7' -0" • 10.1 11.1 12.1 I FG 4 .) PT- 2 0 N N • N N \ N N N \ N N N N \ N N N N N N \ N N \ \ \ N N \ N N \ N N N N N N G N P N N N N N N \ N N N N N 3 N \ \ \ \ \ N 15 -4 N N N N N N N N N N \ N N N \ N N \ N \ N N N F. ALL THRESHOLDS AND FLOOR TRANSITION SHALL BE 1/2" MAX. HEIGHT. , , , , , , , City of Tukwila BUILDING DIVISION THRESHOLD FG -5 FG2 VINYL REVIEWED FOR CCDE COMPLIANCE APPROVED JAN 0 6 2010 EXIST. GONG SLAB. PREPARE SMOOTH ff LEVEL TO ACCEPT NEW FLOOR FINISHES MAT TRANSITION DETAIL SCAM 3 -T-0' TOILET RM BASE DETAIL SCALE 3' -T-0' NON -SALES BASE DETAIL SCALE! 3' • T-0' SALES BASE DETAIL SCALE 3' JOHNSONITE # GTA -45 -G, SANDLE WOOD TRANSI • • � .•.`. h . VINYL TRANSITION DETAIL SCALE 3' -T-0' FG2 FG4 VINYL OR Y.G.T. - VGT FRP NAINSGOT FG3 FG3 B -I PT -I PT -I BOTTOM DOOR RAIL 5-2 FG4 N WALL FINISH PER ELEV. VGT FLOORING WALL FINISH PER ELEV. T -6 SHOE MOLDING CAULK AS REG. FLOOR FINISH - SCHEDULED FG5 MAT 0:1°11i,,!. ilill 0,1 ",!I ,Illil' WALK -OFF MAT FGI FG3 VINYL EXTERIOR GONGRETE INALK RECEIVED CITY OF TUKVVILA TRANSITION DETAIL DEC 2 2 2009 PERMIT CENTER DATE: 11/15/09 JOB NO: 09-06(2 DRAWN: STAFF CHECKED: KI3 3405 KENNETH L. BUTTS ARCHITECT AIA 124 STAGECOACH ROAD BELL CANYON, CA 91307 (818) 999-4272 REGISTERED KENNETH L. BUTTS STATE OF WASHINGTON CADDR(11 225 OAKUM) RAOC, NE 105 1E.: (960) 183-5610 SOUTH 1114,50R, CT 0b014 FAX: (860)183-5690 • Er W L 0 NOQz 0 tV SHEET TITLE 0 ma to STORE NUMBER itTBD REVISIONS 'A' ISSUE: LANDLORD COMMENTS DATE: 12/1/09 DATE rDATE 'Di ISSUE DATE R.00R FINISH PLAN SCALE SHEET NUMBER A1.2 HARDWARE FOR SALES AREA STANDARDS LOCATION cc LLl m am CL Z a fY Nd18 El3d /kW aavaNnis dO 'oN TOTAL PIECES No. OF STNDS DESCRIPTION REMARKS END GAP EG5 -SG 1 8 20 FIXED NUMBER CENTER SHELF BRACKET GFGI3SG GRI2 SS3O120GSH 45 FIXED NUMBER LEFT SHELF BRACKET w /CUP GFLHI2SGP24 SPLIGER FOR REGT. TUBING RE /5P 24 FIXED NUMBER LEFT SHELF BRAGKET GFLHI3SGP24 41 +15 6' DISPLAY HANDRAIL 67 FIXED NUMBER RIGHT SHELF BRACKET w /CUP GFRHI2SGP24 63 24 FIXED NUMBER RIGHT SHELF BRAGKET GFRHI3SGP24 67 FIXED NUMBER 3" HVY DTY BRKT REGT TBG -SATIN CHROME GR3 -SG 7 82 514 12" HVY DTY BRKT REGT TBG -SATIN CHROME GRI2 -SG I 82 82 3 ", 12" COMBO BRKT W/SM SATIN GHROME RHDUBI2SG 30 FIXED NUMBER 12" FADEOUT FOR WALL STND -SATIN CHROME RRI2 -SG 10 FIXED NUMBER a" SADDLE MOUNT HOOK SATIN CHROME HISG 8 82 656 2' DISPLAY HANDRAIL, W/ WELDED END GAP RE26EG45G 120 FIXED NUMBER 3' DISPLAY HANDRAIL, W/ WELDED END GAP RE36EG4SG 60 FIXED NUMBER 4' DISPLAY HANGRA I L RE45G 40 FIXED NUMBER 4' DISPLAY HANDRAIL, W/ WELDED END GAP RE48EG4SG 112 FIXED NUMBER 5' DISPLAY HANDRAIL, W/ WELDED END GAP RE6OEG4SG 20 FIXED NUMBER 12" FADEOUT REG HOZ MNT SATIN CHROME RH /12 -SG 10 82 820 SADDLE w/PUGK SATIN CHROME SPII2SGPIO 80 FIXED NUMBER HARDWARE FOR NON -SALES AREA STANDARDS LOCATION W Ic m am z SNO1LO3S .9 a2d /'JLLO SNO11O3S .9 dO 'oN QTY./ PER STND No. OF STNDS TOTAL PIECES DESCRIPTION STOCK AREA END GAP FOR REGT TBG w /I" EXT EG5 1 8 SS3O120GSH 28 56 12" HVY DUTY BRAGKET/REGT TUBING GRI2 SS3O120GSH 4 1 28 116 SPLIGER FOR REGT. TUBING RE /5P 1 1 41 +15 6' DISPLAY HANDRAIL RE6 1 1 63 DESCRIPTION OFFICE /RECEMNG AREA 12" SHELF KNIFE BRACKET GSBLI2 36 WALL STANDARDS LOCATION DESCRIPTION PART QTY REMARKS PERIMETER WALL SALES AREA 8' SURFACE MOUNT STANDARD w/ WHITE FINISH 5530�f6G5H 82 G.G. TO SUPPLY ALL MOUNTING HARDWARE PERIMETER WALL STOCK AREA 10' SURFAGE MOUNT STANDARD w/ ZING FINISH SS3O120GSH 28 G.G. TO SUPPLY ALL MOUNTING HARDWARE BREAK AERA STOGK AREA 6' SURFACE MOUNT STANDARD w/ ZING FINISH SS3O120GSH 4 G.G. TO SUPPLY ALL MOUNTING HARDWARE OFFICE AREA 4' SURFACE MOUNT STANDARD w/ ZING FINISH 553048GSH 4 G.G. TO SUPPLY ALL MOUNTING HARDWARE -N- 0 C OFFICE 104 73 SQ /FT =2/ O J 5 9 / (8) IO'L. SURFACE MTD. STANDARDS @ 24" O.G. 1' -2" I' 2" 14' -10" LEASE DIMENSION 54' -O" (36) 8'L SURFACE MTD. STANDARDS @ 24" O.G. WALL STANDARDS INSTALLATION PLAN �II1 I` PLAN SCALE: 1/4' •. T-O' I �1�, NORTH 10' -0" WALL STANDARDS INSTALLATION NOTES: TENANT WORK SALES FLOOR: 100 HALL: 101 2 INSTALL PROVIDED 8' LONG SURFACE MOUNTED STANDARDS AS INDICATED IN THE PLAN. PROVIDE HILTI TODDLERS # 00314508, ALL SCREW HEADS ARE TO BE SPRAY PAINTED WHITE TO MATCH THE WALL STANDARDS NO SHELVING REQUIREMENTS TOILET ROOM: 102 AND 103 3 INSTALL PROVIDED CABINETS OVER WATER CLOSETS. GENERAL NOTES: / OFFICE: 104 0 STOCKROOM: 105 5 61 I. STANDARDS TO BE INSTALLED USING HILTI TODDLERS # 00314508 2. WHITE FINISH STANDARDS IN SALES AREA WITH HARDWARE INSTALLED 3. INSTALL HANGBAR AT TOP OF STANDARDS THROUGHOUT SALES AREA (COORDINATE WITH TENANT FOR EXACT LOCATION. 4. TENANT PROVIDED GRAPHICS TO BE INSTALLED (COORDINATE EXACT LOCATION WITH TENANT). 5. ALL STANDARDS IN SALES AREA TO BE MOUNTED 12" A.F.F. (NO EXCEPTIONS). CONTACT COORDINATE WITH OWNER IF FLOOR IS NOT LEVEL. (3) IO'L. SU,EAG MTD. STANDARDS ® 24" O.G. 4' -0" 3 1 HC TOILET MENS ROOM 103 64 SQ /FT =1% HALL 101 108 SO /FT -4Z 14' -0" HC TOILET WOMENS ROOM 102 58 SQ /FT =1% (28) 8'L SURFACE MTD. STANDARDS ' 24" O.G. SALES AREA 100 3301 SO/FT= 82% INSTALL 4' LONG SURFACE MOUNTED STANDARDS AND PLASTIC LAMINATE SHELVING OVER MANAGERS DESK AS SHOWN IN ELEVATION. SEE SHEET A3.4 INSTALL 10' AND 6' LONG SURFACE MOUNTED STANDARDS AND ALL REQUIRED HANGBARS AND ACCESSORIES AND INDICATED. SEE FIXTURE PLAN SHEET AI.4 AND STOCKROOM ELEVATIONS SHEET A3.4 SEE DETAIL 6/A5.I FOR HANG BAR INSTALLATION. INSTALL NEW EXCALIBUR SHELVING UNIT AS SHOWN. SEE MFG'S INFORMATION MANUAL FOR COMPLETE INSTALLATION DETAILS. GENERAL ASSEMBLY INFORMATION SEE SHEET A5.I / / / / / z O N z 1 R EVIEWED FOR CODE COMPLIANCE A PPROVED J AN 0 6 2010 City of Tukwila BUILDING DIVISION RECEIVED CITY OF TUKWILA DEC 2 2 2009 PERMIT CENTER DATE: JOB NO: DRAWN: CHECKED: 11/1 09 -066 STAFF KB KENNETH L. BUTTS ARCHITECT AIA 124 STAGECOACH ROAD BELL CANYON, CA 91307 (818) 999 -4272 KENNETH L. BUTTS STATE OF WASHINGTON (ADDTzti D• E • S• I • G• N 225 OAKLAND RAM, 81111E 105 1EL: (860)183 -5610 SOU1N WWDBOR, CT 06014 FAX: (860)183-5680 DEC 0 8 2009 LIJ A- Mcc D co W 0 Z vl W 40 • N1/4.,<Z W � D N � � O D O- ,N I- I- (0 CD 4• V STORE NUMBER %TBD REVISIONS 'A'- ISSUE: LANDLORD COMMENTS DATE: 12/1/05 'B' -ISSUE DATE 'C' -ISSUE DATE 'D'- ISSUE DATE SHEET TITLE WALL STANDARDS INSTALLATION PLAN SCALE 114 - 1 SHEET NUMBER A1.3 N C to TOTAL AREA 4,000 Sq. Ft. AREA BREAK DOWN AREA SO. FT. X SALES AREA 3301 mod - - '�0 HALL 108 H.G. TOILET RM5 58 H.G. TOILET RMS 64 OFFICE 73 STOCK ROOM 105 3a6 TOTAL: 4,000 SQ. FT. 100% FLOOR FIXTURING / MILLWORK SCHEDULE ACCESSORIES FOR FLOOR FIXTURES MARK TYPE DESCRIPTION MFG. I SUPPLIER PART QTY REMARKS V c13i a_ : Z 3HJ 11Xd dad /MD S3dfLLXd AO '°N TOTAL PIECES RETAIL AREA RXTURES F-1 MILLWORK GASHIARAP/BAGKINRAP MILLSHOP X 1 BLUE COVE BASE "B3" ENTIRE INSIDE AND OUTSIDE DESCRIPTION FLOOR RXTURES REMARKS F -2 MILLWORK ACCESSORY FIXTURE MILLSHOP X 0 BLUE COVE BASE "33" ENTIRE INSIDE AND OUTSIDE 36" ADD ON HANDRAIL SATIN CHROME KH5SGPK4 I 14 14 F-3 MILLWORK MULTI PURPOSE MILLSHOP X 6 54" GARMENT RETRIEVER P48 5 FIXED NUMBER COLLAPSIBLE GARMENT RACK RGS /I OR RG5 /2 5 FIXED NUMBER F -4 MILLWORK TALL MULITI -UNIT FIXTURE MILLSHOP X O ROUNDER SUPPORT SATIN CHROME (each) RSUPSG 4 30 q0 F -5 METAL ROUND RAGK FIXTURE FIXTURE VENDOR K52381^IDSGWG + 8 +8 = SIDE WALK FIXTURES RUBBER MALLET RM /I 2 FIXED NUMBER COUNTER TOP METAL T -STAND TSDSN 4 FIXED NUMBER F -6 METAL 4 -WAY FIXTURE FIXTURE VENDOR KISOBRKTSGWG 30 SATIN CHROME 16" TWIST ON ARM FOR F -6 TVI 4 30 6 10 F-7 MILLWORK I -BEAM MILLSHOP X 4 BLACK LOCKING CASTER FOR F -5/F -6 TW4 -38 I 44 44 4" SLATWALL HOOK SW/H4 20 FIXED NUMBER F -8 MILLWORK NESTING TABLE FIXTURE FIXTURE VENDOR X 4 SUPPLIED BY VENDOR • F-10 MILLWORK LEGO TABLE tt CHAIR FIXTURE FIXTURE VENDOR X I SUPPLIED BY VENDOR ASSEMBLED IN FIELD HARDWARE INCLUDED RETAIL SHELVING F-1 MILLWORK PLATFORM FIXTURE FIXTURE VENDOR X 2 SUPPLIED BY VENDOR DEPARTMENT DEPARTMENT GOAL ACTUAL DESIGN WG -1 METAL GRAPHIC DISPLAY GRID I x 5 WHITE WIRE GRID FIXTURE VENDOR 15GRDW 3 ASSEMBLED IN FIELD TOTAL �_ (44) 4 SECTIONS = 176 L.F. (3a) 4' SECTIONS = 156 L.F. fit 0 1 OFFICE 104 73 SQ FT =2X 10 I I r STOCK ROOM 105 396 SO/FT= 10% 6I o HC TOILET MENS ROOM 103 64 SQ /FT =1X NNW MN MI NM MI MIL if- NM MI 5 108 SO /FT =4X HALL 101 6I HC TOILET WOMENS ROOM 102 58 SQ /FT -1X / //N • i - N � No I 1 CLEARANCE / / 8' -0" CO = >- Tx) O / �� \ ( I CD L 1 z 8' -0" INFANT GIRLS i / LEASE DIMENSION F -6 F -7 III F -7 F-6 n 74' -I0" 28' -0" FIXTURE PLAN UMW-VC F -6 F -6 w 4 w F -6 F -6 TODDLER GIRLS n F -6 n F -6 F -6 F -6 PLAN NORTH 1 I SALES AREA 100 3301 SO/FT= 82X 0 m z I F -6 \� / / u u F-7 O m F -6 n BABY BOYS 28' -O" F-6 F-6 ,•. \ / i•. \ //\\ \\ FIXTURE PLAN NOTES: TENANT WORK SALES AREA: 100 2 3 4 I HALL: 101 5 F-6 F-6 F -6 F-6 F-6 F-6 INSTALL PROVIDED SURFACE MOUNTED STANDARDS, HITLI TODDLERS FOR EACH 8' -O" SALES AREA STANDARD, COORDINATE WITH STORE MANAGER FOR INSTALLATION OF ALL PERIMETER HARDWARE AND SHELVES. SEE STANDARDS INSTALLATION PLAN SHEET A -13 ASSEMBLE AND INSTALL ALL TENANT SUPPLIED FLOOR FIXTURES. A MAIN ACCESS AISLE FROM THE STOREFRONT ENTRY TO THE HALL DOOR SHALL BE PROVIDED 44" WIDE, THE MINIMUM WIDTH OF DISPLAY AISLES SHALL BE 36 ". G.G. TO INSTALL GASHDESK AS DIMENSIONED. HANDICAP CHECK OUT COUNTERS SHALL BE PROVIDED AT A SECTION OF THE GOUNTER THAT 15 AT LEAST 36" LONG AND NO MORE THAN 34" HIGH FOR BOTH EMPLOYEES AND CUSTOMERS. FIRE EXTINGUISHER SHALL BE 10 L.B. MULTIPURPOSE DRY CHEMICAL (GLASS A,B,G) RATED NOT LESS THAN 2A -IOBC MOUNTED 36" A.F.F. MAX. TRAVEL DISTANCE SHALL NOT BE MORE THAN 15 FEET PER NFPA 10 NO FIXTURING REQUIREMENTS THIS AREA. n u 56 BABY GIRLS \ \ 6 n V 7 \ \ i F -6 F -6 n \ \ tl ICI 41 rtr I_ RI HC TOILET ROOM WOMENS: 102 HC TOILET ROOM MENS: 103 6 INSTALL ALL TENANT SUPPLIED ACCESSORIES WITH -IN TOILET ROOMS AS NOTED, COORDINATE WITH FIXTURE SCHEDULE AND ELEVATIONS. SEE SHEET A3.3 OFFICE: 104 1 INSTALL PROVIDED OFFICE COUNTERS, INSTALL WALL STANDARDS AND SHELVES. SEE ELEVATIONS SHEET A3.4 STOCKROOM: 105 8 a 10 II 12 IS INSTALL ALL PROVIDED STOCKROOM WALL STANDARDS AND BRACKETS. HITLI TODDLERS FOR EACH 10' -0" STOCK AREA STANDARDS. SEE STANDARDS INSTALLATION PLAN SHEET AI.2 AND STOCKROOM ELEVATIONS SHEET A3.4 INSTALL SUPPLIED BREAK TABLE AND HALL MOUNTED CORK BOARD INSTALL MICROWAVE, REFRIG. AND WALL MOUNTED GLOGK INSTALL LOCKERS, ATTACH TO WALL USING HILTI TODDLER SYSTEM. INSTALL PROVIDED HARDWARE BIN. INSTALL SHELVING SYSTEM PER SHEET A5.I i i N N z O z w 4 1) 09 2 CODE FOR ODE COMPLIANCE APPROVED JAN 0 6 2010 City of Tukwila BUILDING DIVISION CITY OF TUKWILA DEC 2 2 2009 PERMIT CENTER DATE: JOB NO: DRAWN: CHECKED: 3405 11/15/09 09 -055 STAFF KB DEC 0 8 2009 W a- cc W co U z °° Woo ac U D • W0Qz U w I— O U D N � CD F r CD CD CO KENNETH L. BUTTS ARCHITECT AIA 124 STAGECOACH ROAD BELL CANYON, CA 91307 (818) 999 -4272 K`� L. B T TS STATE OF WASHINGTON REGISTERED AIZGHITE T (ADDTzti • E • S• I • G• N 225 OAKLAND RAOD, SUITE 105 111: (860)183 -5610 SOUTH 13.0508, CT 06014 f4X: (860)183-5680 ma C l0 STORE NUMBER SHEET TITLE %TBD REVISIONS 'A' - ISSUE: LANDLORD COMMENTS DATE: 12/1/05 'B'- ISSUE DATE 'C' -ISSUE DATE 'D'- ISSUE DATE FLOOR FIXTURING / FA I WORD PLAN SCALE 1/4' -T-0' SHEET NUMBER A1.4 TOTAL AREA 4,000 Sq. Ft. 4.1 5.1 ROOM 101 HEIGHT 10' -0" HEIGHT 10' -ON MISC. ACT TYPE CL1 MISC. ACT 7.I 8.I ROOM HEIGHT TYPE CL1 MISC. ACT 7.1 MS .11 ROOM 102 HEIGHT TYPE CL1 MISC. ACT EQUAL HEIGHT 10' -ON TYPE CL1 MISC. ACT. EQUAL I I.1 12.1 1511 HEIGHT DECK MISC. OPEN ROOM TYPE 105 CL2 X/1 O 1- F 8' -O" F I Y1 F SEISMIC, SEPARATION JOINT PER DETAIL SG / A4.2 REFLECTED CEILING PLAN SCALE: 1/4' CEILING TYPES: CLi ICL2 A. SALES AREA SUSPENDED ACOUSTICAL CEILING: USG "DONN DX" 15/16 ", 2 X 4 TEE GRID SUPPLIED AND INSTALLED BY G.G. ACOUSTICAL TILES: 2 X 4 X 5/5" USG "FISSURED" (SQ) 44562 SUPPLIED AND INSTALLED BY L.L. SEE INSTALLATION DETAIL 8/A4.2 OPEN TO STRUCTURE CEILING MISC. CEILING LEGEND: TENANTS SECURITY CAMERA DOME SUPPLY AIR REGISTER, SEE MECHANICAL DRAWINGS RETURN AIR REGISTER, SEE MECHANICAL DRAWINGS FIRE PROTECTION NOTES: SPRINKLER SYSTEMS: B AN AUTOMATIC FIRE SPRINKLER SYSTEM 15 EXISTING WITHIN THIS SPACE. THE LANDLORD SHALL MODIFY THE SYSTEM AS REQUIRED FOR THE SPACE CONFIGURATION. MODIFICATIONS SHALL BE DESIGNED AND INSTALLED BY A LICENSED SPRINKLER CONTRACTOR, WHO SHALL PREPARE DESIGN / SHOP DRAWINGS OF THE SYSTEM AND SUBMIT SUCH DRAWINGS TO THE LANDLORD AND BUILDING AND FIRE DEPARTMENTS FOR APPROVAL PRIOR TO FABRICATION AND INSTALLATION. ALL WORK SHALL BE DONE IN ACCORDANCE WITH NFPA, STANDARD 13, AND ANY OTHER STATE OR LOCAL CODES HAVING JURISDICTION. -THE LANDLORD SHALL HIRE THE SPRINKLER CONTRACTOR FOR THE MODIFICATIONS. -THE SPRINKLER CONTRACTOR SHALL PREPARE COMPLETE SHOP DRAWINGS AND SUBMIT TO LANDLORD, AND FIRE DEPARTMENT FOR APPROVAL. - SPRINKLER CONTRACTOR SHALL APPLY FOR AND ACQUIRE ALL REQUIRED PERMITS FROM FIRE MARSHALS OFFICE AS REQUIRED PRIOR TO INSTALLATION OF THE SYSTEM. - SPRINKLER HEADS IN THE ACOUSTICAL CEILINGS SHALL BE SEMI RECESSED W/ CHROME TRIM - ALL HEADS SHALL BE CENTERED IN CEILING TILES. - SPRINKLER HEADS IN GYP. BD CEILINGS SHALL BE FULLY RECESSED WITH WHITE POP OFF COVERS FIRE ALARM SYSTEMS: FIRE ALARM SYSTEM SHALL BE SUPPLIED AND INSTALLED BY THE LANDLORD IN ACGORADNCE WITH NFPA 12. CEILING PLAN NOTES: LL WORK SALES FLOOR: 100 1.1 HALL: 101 4.1 6.1 HC TOILET ROOM WOMENS: 102 HC TOILET ROOM MENS: 103 LANDLORD TO SUPPLY AND INSTALL 2 X 4 ACOUSTICAL CEILING AS SHOWN. LANDLORD TO SUPPLY AND INSTALL 2 X 4 FLUORESCENT LIGHT FIXTURES 'Al" AS SHOWN. OFFICE: 104 8.1 a.1 10.1 Ea LANDLORD TO SUPPLY AND INSTALL NEV ACOUSTICAL CEILING SYSTEM AS SHOWN. LANDLORD TO SUPPLY AND INSTALL EXIT LIGHT FIXTURES "X" AS SHOWN. LANDLORD TO SUPPLY AND INSTALL NEW 2 X 4 FLUORESCENT LIGHT FIXTURES "A" AND "A/EM" AS SHOWN. LANDLORD TO SUPPLY AND INSTALL 2 X 4 ACOUSTICAL CEILING AS SHOWN. LANDLORD TO SUPPLY AND INSTALL 2 X 4 EMERGENCY LIGHT FIXTURE "Al/EM" AS SHOWN. LANDLORD TO SUPPLY AND INSTALL EXIT LIGHT FIXTURES "X" AND "X /I AS SHOWN. LANDLORD TO SUPPLY AND INSTALL 2 X 4 ACOUSTICAL CEILING AS SHOWN. LANDLORD TO SUPPLY AND INSTALL 2 X 4 FLUORESCENT LIGHT FIXTURE "AI" AS SHOWN. STOCKROOM: 105 OPEN STRUCTURAL CEILING AS SHOWN. LANDLORD TO SUPPLY AND INSTALL 4' FLUORESCENT LIGHT FIXTURES "F" AS SHOWN. 131 LANDLORD TO INSTALL EXIT LIGHT FIXTURES "X" AND EMERGENCY LIGHT FIXTURES "Y" AS SHOWN. MISCL. LANDLORD TO PROVIDE AND INSTALL REAR SERVICE DOOR BUZZER SYSTEM ABOVE CEILING AT GASHWRAP, AND IN STOCKROOM JUST OUTSIDE THE OFFICE. \ ALL WORK BY LANDLORD UNDER LANDLORD PERMIT. CEILING PLAN NOTES: TENANT WORK STOREFRONT: 0 SALES FLOOR: 100 0 O I in y NEW EXTERIOR 51GNS BY TENANT SIGN CONTRACTOR UNDER SEPARATE PERMIT. JUNCTION BOX FOR POWER BY LANDLORD., SEE ELECTRICAL DRAWINGS. G.G. TO INSTALL PROVIDED STOREFRONT WIRE GRID POSTER TRACK SYSTEM. SEE INSTALLATION DETAIL 1/A4.2 G.G. TO INSTALL TRACK MOUNTED "BI" METAL HALIDE. G.G. TO INSTALL SEMI RECESSED WALL WASH ACCENT LIGHTING FIXTURES "B" ALONG THE PERIMETER AS INDIGATED MUSIC SYSTEM SPEAKERS AND WIRE PROVIDED BY TENANT. LOW VOLTAGE SYSTEM VENDOR TO INSTALL SYSTEM. INSTALLATION DIAGRAM PROVIDED WITH SPEAKERS. ALL SPEAKERS ARE FLUSH MOUNTED TO CEILING. G.G. SHALL INSTALL POWER AND J -BOX FOR SPEAKER WIRE BACK AT THE MANGERS OFFICE ONLY. u bOq- z�q REVIEWED FOR CODE COMPLIANCE APPROVED JAN 0 6 2010 City of Tukwila B UILDING DIIISInW CITY OF TUKWILA DEC 2 2 ?..009 PERMIT CENTER DATE: JOB NO: DRAWN: CHECKED: REGISTERED A• s i'� ETH L. BUTTS STATE OF WASHINGTON 3405 11/15/09 09 -066 STAFF KB ( D• E • S• I • G• NI 115 OAKLAND RAOD, 5UITE 105 1EL (860)183 - 5610 SOUTH WINDSOR, CT 06014 FAX: (860)183 -5680 DEC 0 8 2009 W a-- L` cc Q W �Zr W oo CC 0 r • WO ((Li I- 0 U D N � O :D cL CD F— O) KENNETH L. BUTTS ARCHITECT AIA 124 STAGECOACH ROAD BELL CANYON, CA 91307 (818) 999 -4272 SHEET TITLE STORE NUMBER SCALE 1/4' - T SHEET NUMBER A2.1 %TBD REVISIONS 'A'- ISSUE: LANDLORD COMMENTS DATE: 12/7/09 -ISSUE DATE 'C'- ISSUE DATE 'D' -ISSUE DATE RER.ECTED C:EUNG PLAN LIGHT FIXTURE SCHEDULE SYM MARK DESGRIPTION MFG CATALOG* LAMP TYPE VOLTAGE MOUNTING QTY REMARKS A 2x4 FLUORESCENT FIXTURE (2) LAMP HIGH OUTPUT T -5 METALUX 2AG - 254W T5 -UNV (2) 54W /T -5 3500K UNIV RECESSED 44 SUPPLIED /INSTALLED BY L.L. 0 A /EM 2x4 FLUORESCENT FIXTURE (2) LAMP HIGH OUTPUT T -5, WITH EMERGENCY BALLAST AND GO MINUTE BATTERY BACK -UP METALUX 2AG - 2541A1T5 -UNV (2) 54W/T -5 3500K UNIV RECESSED 6 SUPPLIED /INSTALLED BY L.L. -104 ''`y` Al 2x4 FLUORESCENT FIXTURE WITH PRISMATIC DIFFUSER METALUX 2GR8- FA232A- UNIV -EB81 (2) 32W -T8 UNIV RECESSED 3 SUPPLIED /INSTALLED BY L.L. 0 MEM 2x4 FLUORESCENT FIXURE WITH PRISMATIC DIFFUSER WITH EMERGENCY BALLAST AND d10 MIN. BATTERY METALUX 2GR8- FA232A- UNIV -EM -EBB1 (2) 321A1-T8 UNIV RECESSED I SUPPLIED /INSTALLED BY L.L. A. • °r B SEMI RECESSED WALL WASH FIXTURE GON - TECH RA8470MHE - IOW /EB -11 UNIV RECESSED 21 TENANT SUPPLIED /INSTALLED BY G.G. B1 /X' TRACK MOUNTED METAL HALIDE WALL WASHER, MOUNTED IN SINGLE CIRCUIT TRACK, COLOR WHITE GON -TECH GTL7017WW -P -LF- 100 -UV - 11 -I� UNIV TRACK MOUNT (4) heads (I) 16' TRK TENANT SUPPLIED /INSTALLED BY G.G. F 4' (2) LAMP FLUORESCENT STRIP METALUX SNF -132- UNV -EB81 (I) 32WTS RUBBER COATED SHATTER PROOF LAMPS UNIV SUSPENDED 7 SUPPLIED /INSTALLED BY L.L. I I x LED EDGE -LIT EXIT SIGN WITH c10 MIN BATTERY BACK -UP NAVILITE NXESB NXESBIRAAES INCLUDED UNIV UNIVERSAL 2 SUPPLIED /INSTALLED BY L.L. �_A X/1 STANDARD LED EXIT SIGN WITH q0 MIN BATTERY BACK -UP ASTRALITE TP- U- R -W -EM INCLUDED UNIV UNIVERSAL I SUPPLIED /INSTALLED BY L.L. ■■I Y DOUBLE HEAD EMERGENCY WITH qo MIN BATTERY BACK - UP HIGHLITES HL -qO -DL INGULDED UNIV SURFACE SUSPENDED 2 SUPPLIED /INSTALLED BY L.L. SEE PLAN FOR LOCATION ® S AUDIO SPEAKERS RECESSED 8 TENANT SUPPLIED /INSTALLED BY G.G. 4.1 5.1 ROOM 101 HEIGHT 10' -0" HEIGHT 10' -ON MISC. ACT TYPE CL1 MISC. ACT 7.I 8.I ROOM HEIGHT TYPE CL1 MISC. ACT 7.1 MS .11 ROOM 102 HEIGHT TYPE CL1 MISC. ACT EQUAL HEIGHT 10' -ON TYPE CL1 MISC. ACT. EQUAL I I.1 12.1 1511 HEIGHT DECK MISC. OPEN ROOM TYPE 105 CL2 X/1 O 1- F 8' -O" F I Y1 F SEISMIC, SEPARATION JOINT PER DETAIL SG / A4.2 REFLECTED CEILING PLAN SCALE: 1/4' CEILING TYPES: CLi ICL2 A. SALES AREA SUSPENDED ACOUSTICAL CEILING: USG "DONN DX" 15/16 ", 2 X 4 TEE GRID SUPPLIED AND INSTALLED BY G.G. ACOUSTICAL TILES: 2 X 4 X 5/5" USG "FISSURED" (SQ) 44562 SUPPLIED AND INSTALLED BY L.L. SEE INSTALLATION DETAIL 8/A4.2 OPEN TO STRUCTURE CEILING MISC. CEILING LEGEND: TENANTS SECURITY CAMERA DOME SUPPLY AIR REGISTER, SEE MECHANICAL DRAWINGS RETURN AIR REGISTER, SEE MECHANICAL DRAWINGS FIRE PROTECTION NOTES: SPRINKLER SYSTEMS: B AN AUTOMATIC FIRE SPRINKLER SYSTEM 15 EXISTING WITHIN THIS SPACE. THE LANDLORD SHALL MODIFY THE SYSTEM AS REQUIRED FOR THE SPACE CONFIGURATION. MODIFICATIONS SHALL BE DESIGNED AND INSTALLED BY A LICENSED SPRINKLER CONTRACTOR, WHO SHALL PREPARE DESIGN / SHOP DRAWINGS OF THE SYSTEM AND SUBMIT SUCH DRAWINGS TO THE LANDLORD AND BUILDING AND FIRE DEPARTMENTS FOR APPROVAL PRIOR TO FABRICATION AND INSTALLATION. ALL WORK SHALL BE DONE IN ACCORDANCE WITH NFPA, STANDARD 13, AND ANY OTHER STATE OR LOCAL CODES HAVING JURISDICTION. -THE LANDLORD SHALL HIRE THE SPRINKLER CONTRACTOR FOR THE MODIFICATIONS. -THE SPRINKLER CONTRACTOR SHALL PREPARE COMPLETE SHOP DRAWINGS AND SUBMIT TO LANDLORD, AND FIRE DEPARTMENT FOR APPROVAL. - SPRINKLER CONTRACTOR SHALL APPLY FOR AND ACQUIRE ALL REQUIRED PERMITS FROM FIRE MARSHALS OFFICE AS REQUIRED PRIOR TO INSTALLATION OF THE SYSTEM. - SPRINKLER HEADS IN THE ACOUSTICAL CEILINGS SHALL BE SEMI RECESSED W/ CHROME TRIM - ALL HEADS SHALL BE CENTERED IN CEILING TILES. - SPRINKLER HEADS IN GYP. BD CEILINGS SHALL BE FULLY RECESSED WITH WHITE POP OFF COVERS FIRE ALARM SYSTEMS: FIRE ALARM SYSTEM SHALL BE SUPPLIED AND INSTALLED BY THE LANDLORD IN ACGORADNCE WITH NFPA 12. CEILING PLAN NOTES: LL WORK SALES FLOOR: 100 1.1 HALL: 101 4.1 6.1 HC TOILET ROOM WOMENS: 102 HC TOILET ROOM MENS: 103 LANDLORD TO SUPPLY AND INSTALL 2 X 4 ACOUSTICAL CEILING AS SHOWN. LANDLORD TO SUPPLY AND INSTALL 2 X 4 FLUORESCENT LIGHT FIXTURES 'Al" AS SHOWN. OFFICE: 104 8.1 a.1 10.1 Ea LANDLORD TO SUPPLY AND INSTALL NEV ACOUSTICAL CEILING SYSTEM AS SHOWN. LANDLORD TO SUPPLY AND INSTALL EXIT LIGHT FIXTURES "X" AS SHOWN. LANDLORD TO SUPPLY AND INSTALL NEW 2 X 4 FLUORESCENT LIGHT FIXTURES "A" AND "A/EM" AS SHOWN. LANDLORD TO SUPPLY AND INSTALL 2 X 4 ACOUSTICAL CEILING AS SHOWN. LANDLORD TO SUPPLY AND INSTALL 2 X 4 EMERGENCY LIGHT FIXTURE "Al/EM" AS SHOWN. LANDLORD TO SUPPLY AND INSTALL EXIT LIGHT FIXTURES "X" AND "X /I AS SHOWN. LANDLORD TO SUPPLY AND INSTALL 2 X 4 ACOUSTICAL CEILING AS SHOWN. LANDLORD TO SUPPLY AND INSTALL 2 X 4 FLUORESCENT LIGHT FIXTURE "AI" AS SHOWN. STOCKROOM: 105 OPEN STRUCTURAL CEILING AS SHOWN. LANDLORD TO SUPPLY AND INSTALL 4' FLUORESCENT LIGHT FIXTURES "F" AS SHOWN. 131 LANDLORD TO INSTALL EXIT LIGHT FIXTURES "X" AND EMERGENCY LIGHT FIXTURES "Y" AS SHOWN. MISCL. LANDLORD TO PROVIDE AND INSTALL REAR SERVICE DOOR BUZZER SYSTEM ABOVE CEILING AT GASHWRAP, AND IN STOCKROOM JUST OUTSIDE THE OFFICE. \ ALL WORK BY LANDLORD UNDER LANDLORD PERMIT. CEILING PLAN NOTES: TENANT WORK STOREFRONT: 0 SALES FLOOR: 100 0 O I in y NEW EXTERIOR 51GNS BY TENANT SIGN CONTRACTOR UNDER SEPARATE PERMIT. JUNCTION BOX FOR POWER BY LANDLORD., SEE ELECTRICAL DRAWINGS. G.G. TO INSTALL PROVIDED STOREFRONT WIRE GRID POSTER TRACK SYSTEM. SEE INSTALLATION DETAIL 1/A4.2 G.G. TO INSTALL TRACK MOUNTED "BI" METAL HALIDE. G.G. TO INSTALL SEMI RECESSED WALL WASH ACCENT LIGHTING FIXTURES "B" ALONG THE PERIMETER AS INDIGATED MUSIC SYSTEM SPEAKERS AND WIRE PROVIDED BY TENANT. LOW VOLTAGE SYSTEM VENDOR TO INSTALL SYSTEM. INSTALLATION DIAGRAM PROVIDED WITH SPEAKERS. ALL SPEAKERS ARE FLUSH MOUNTED TO CEILING. G.G. SHALL INSTALL POWER AND J -BOX FOR SPEAKER WIRE BACK AT THE MANGERS OFFICE ONLY. u bOq- z�q REVIEWED FOR CODE COMPLIANCE APPROVED JAN 0 6 2010 City of Tukwila B UILDING DIIISInW CITY OF TUKWILA DEC 2 2 ?..009 PERMIT CENTER DATE: JOB NO: DRAWN: CHECKED: REGISTERED A• s i'� ETH L. BUTTS STATE OF WASHINGTON 3405 11/15/09 09 -066 STAFF KB ( D• E • S• I • G• NI 115 OAKLAND RAOD, 5UITE 105 1EL (860)183 - 5610 SOUTH WINDSOR, CT 06014 FAX: (860)183 -5680 DEC 0 8 2009 W a-- L` cc Q W �Zr W oo CC 0 r • WO ((Li I- 0 U D N � O :D cL CD F— O) KENNETH L. BUTTS ARCHITECT AIA 124 STAGECOACH ROAD BELL CANYON, CA 91307 (818) 999 -4272 SHEET TITLE STORE NUMBER SCALE 1/4' - T SHEET NUMBER A2.1 %TBD REVISIONS 'A'- ISSUE: LANDLORD COMMENTS DATE: 12/7/09 -ISSUE DATE 'C'- ISSUE DATE 'D' -ISSUE DATE RER.ECTED C:EUNG PLAN TENANTS SIGN: (INTERNALLY ILLUMINATED REVERSE CHANNEL LETTERS:) MOUNTED TO STOREFRONT RACEWAY. STOREFRONT SECTION SCAL B V4' - T-0' NEW BLADE SIGN 2 -O " k REVESE GUT WHITE VINYL WINDOW GRAPHICS BY SIGN CONTRACTOR ;1- N WINDOW VINYL TYPE "B" 1 yr -r-O' babies and kids WINDOW VINYL TYPE "A" 1 V2' -r-0' REVESE GUT WHITE VINYL WINDOW GRAPHICS BY SIGN CONTRACTOR Carter's i 2' -3" 1' -10 1/8" I' -4 3/4" k carter' babies and kids 36" MAX. T.O. MULLION LEV. q' -6" T.O. SLAB ELEV. 0' -0" k REVERSE GUT - VINYL WINDOW GRAPHICS "A" SCALE. 1/4' E STOREFRONT ELEVATION BLADE SIGN UNISTRUT CHANNEL BY LANDLORD DOUBLED -FACED SIGN PANEL B.O. SIGN 7' -4" A.F.F. MIN. BE 1111111111111111111111111111111111 REVERSE GUT - VINYL WINDOW GRAPHICS "A" �T.0. STOREFRONT ELEV. 2O' -q" 0 T.O. MULLION LEV. q' -6" T.O. MULLION LEV. q' -6" T.O. SLAB ELEV. 0' -0" EXISTING STOREFRONT MASONRY FACADE BLACKOUT EXISTING TRANSOM WINDOWS 4b111MIM p arzu IIIIIIIIIIIIIIIIIIIIIII 4 EMI � ■ I M I 11611 ,.... mo"""w" �" , s I IIMEEME EIElli r wwww 0111111 IMMINOMMON 11111 - 11111111111 111111111111111111111 11111111111111111111111111111111111 TENANTS SIGN: (INTERNALLY ILLUMINATED CHANNEL LETTERS:) MOUNTED TO STOREFRONT NON EXPOSED RAGEWAY. SIGN CONTRACTOR TO PROVIDE SHOP DRAWINGS IN ACCORDANCE WITH ALL LANDLORD CRITERIA. SUBMIT SHOP DRAWINGS TO THE LANDLORD FOR APPROVAL PRIOR TO FABRICATION. ALL SIGNS TO BE IN ACCORDANCE WITH MALL CRITERIA AND LOCAL REQUIREMENTS AND TO BE INSTALLED UNDER SEPARATE PERMIT. REVERSE GUT - VINYL WINDOW GRAPH IGS "A" u - REVERSE GUT VINYL WINDOW GRAPHICS "3" BLADE II SIGN II FTFITTITTITF14114I- 1-1- I+1- ITTla -1- 141 -1=1 =1 1T.;lT R I 1ittjl�iiIIIIitIttIUI tl liti EXISTING GLASS STOREFRONT SCALE1/4' -T-0' LJ SCALD 1/4' T-0' STOREFRONT PLAN PITT HI STOREFRONT ELEVATION 7 i i 7 , / / V, V\ - EXISTING STOREFRONT FAGADA r i r '������ 7 � 7 , 7 r � LUA 7 7 #4 \\\\\ \ \ \ \ \ \ \ \ \ \ 7 i i 7 r r / bo9. REVIEWED FOR CODE COMPLIANCE APPROVED JAN 0 6 2010 City of Tukwila BUILDING DIVISION L - -- CITY OF TUKWILA DEC 2 2 2009 PERMIT CENTER DATE: 11/15/09 JOB NO: 09 -066 DRAWN: STAFF CHECKED: KB 3405 DEC 0 8 2009 W o- cc Q Co O z ° - ° woo CC U r z � • w0 U co H O U N � O�: �c1 CO — HVJ KENNETH L. BUTTS ARCHITECT AIA 124 STAGECOACH ROAD BELL CANYON, CA 91307 (818) 999 -4272 REGISTERED ITECT ENNETH L. BUTTS STATE OF WASHINGTON (ADDTu D• E • S• I • G• N 225 OAKLAND RAOD, SUITE 105 /EL: (860)183 -5610 50111H WINDSOR, CT 06.014 FAX (860)183 -5680 . L- CD Nia co L V SHEET TITLE A3.1 STORE NUMBER %TBD REVISIONS 'A'- ISSUE: LANDLORD COMMENTS DATE: 12/7/09 'B' -ISSUE DATE 'C'- ISSUE DATE 'D '- ISSUE DATE STOREFRONT PLAN ELEVATION AND SECTION SCALE 1/4' - r-o• SHEET NUMBER \\ \ X18 O -7 \ : 1 2 3 8 0-7 ‘\ \ �,,2 PT -2 PT -2I DOOR FRAME TYP. E z z z HANDICAPPED AND GENDER SIGNS SEE DETAIL "A" (A3.3) un INTERIOR ELEVATION SCALD 1/4' - r-C PT -2 FRP -I B -2 8C LE.1/4 - r-r FRP -I B -2 PT -2 L INTERIOR ELEVATION PT -2 L DOOR FRAME TYP. 0 O KEY PLAN SCALE: V3' - T-W —FRP I N HALLNAY BY LANDLORD AT TENANT COST. B.O. GLG. lO' -O" A.F.F. O B.O. GLG. 10' -O" A.F.F. 9 7 4- PT -2 9 DOOR 4 FRAME TYP. 1=E INTERIOR ELEVATION 8cALB 1/4' - r-7 PT -2 FRP -I 5-2 PT -2 t PT -2 5 -2 DOOR 4 FRAME INTERIOR ELEVATION 8CALEa 1/4' - r-V B.O. GLG. IO' -O" A.F.F. P. B.O. GLG. IO' -O" A.F.F. 9 9 d- O zo 9 r = "WHITE" PT -I 1 B -1 "WHITE" PT -I 8CALIE va' - r-V B -I 0\ INTERIOR ELEVATION 4 2\b. L.123 "WHITE" PT -I A B -I "WHITE" PT -I A 5 -I 5 -I B.O. GLG. 10' -O" A.F.F. "WHITE" PT -I 9 O INTERIOR ELEVATION BcuE! 1/4 - r-C INTERIOR ELEVATION SCALB 1/4' - r-O 3CALEf 1/4' - f-a' "WHITE" PT -I 5 -I INTERIOR ELEVATION "WHITE" PT -I "WHITE" PT -I INTERIOR ELEVATION =LBW W - r-C PLI "WHITE" PT -I PT -2 bO92b 1 HEVIEWED FOR CODE COMPLIANCE APPROVED JAN 0 6 2010 City of Tukwila ....••• w•.A .1.f Hp I# I B.O. GLG. 10' -0" A.F.F. T.O. 5TND5 q' -o" A.F.F. T.O. STNDS '1' -O" A.F.F. 9 O O B.O. GLG. lo' -O" A.F.F. L� B.O. GLG. 10' -O" A.F.F. 9 B.O. STNDS I' -O" A.F.F. r ` 9 B.O. GLG. IO' -O" A.F.F. B.O. STNDS I' -O" A.F.F. .F\ O T.O.5TND5 Q' -O" A.F.F. 9 B.O. STNDS I' -O" A.F.F. 0 RECEIVED CITY OF TUKWILA DEC 2 2 2009 PERMIT CENTER DATE: JOB NO: DRAWN: CHECKED: 340 11/15/09 09-066 STAFF KB KENNETH L. BUTTS ARCHITECT AIA 124 STAGECOACH ROAD BELL CANYON, CA 91307 (818) 999 -4272 REGISTERED ECT E ' ETH L. BUTTS STATE Of WASHINGTON (ADDTczri D• E • S • I • G• N 225 OAKLAND RAOD, SUITE 105 TEL: (860)183-5610 SOUTH WIN080R, CT 06014 FAX: (860)183-5680 DEC 0 8 2009 W � W j~co co v Z W oo ar U d - W =Qt Z � O Q2 _j � N Ne O D STORE NUMBER %TBD REVISIONS 'A'- ISSUE: LANDLORD COMMENTS DATE: 12/7/09 'V'- ISSUE DATE 'C' - ISSUE DATE 'D'- ISSUE DATE SHEET TITLE SALES AREA AND OORRDOR ELEVATIONS SCALE 114 - O ' SHEET NUMBER A3.2 N C ld :12 to TC L - T SCHEDULE v 1VI I MENT / ACCESSORIES MARK DESCRIPTION. MOUNTING MFG. MFG. NO. REMARKS CLOTHING HOOK PUCKS VITREOUS CHINA WALL HUNG LAVATORY (WHITE) GOMPLETE WITH, FAUCET, STOPS, DRAIN P -TRAP AND WALL HANGER. FAUCET WALL AMERICAN STANDARD D EGL YN GERAMIX 0321 . 0 - f5 2000.100 E AND SUPPLIED SUPPLI NE L.L. O LOCKING TOILET ROOM WALL CABINET MILLSHOP VITREOUS CHINA WATER CLOSET: ELONGATED BOWL, SEAT, 4 TRIM lb GPF, WITH SUPPLY, STOP, AND WHITE OPEN FRONT SEAT FLOOR TOTO DRAKE SERIES CST SUPPLIED AND INSTALLED BY L.L. C TOILET PAPER HOLDER SURFACE KIMBERLY CLARK Og604 SUPPLIED BY TENANT INSTALLED BY G.G. 0 PAPER TOWEL DISPENSER SURFACE KIMBERLY CLARK 0*1765 SUPPLIED BY TENANT INSTALLED BY G.G. 'rye SOAP DISPENSER SURFACE KIMBERLY CLARK *12145 SUPPLIED BY TENANT INSTALLED BY G.G. 512 24" X 36" FRAMED MIRROR SURFACE BOBRIGK B- 165/2436 SUPPLIED AND INSTALLED BY L.L. © 36" HORIZ. GRAB BAR SURFACE BOBRIGK B -6806 X 36 �� SUPPLIED AND INSTALLED BY L.L. GBI ® 42" HORIZ. GRAB BAR SURFACE BOBRICK B -6806 X 42" SUPPLIED AND INSTALLED BY L.L. €3 . 18" VERTICAL GRAB BAR SURFACE BOBRIGK B -6806 X18" SUPPLIED AND INSTALLED BY L.L. MOP SINK FAUCET - SEE SHEET A3.3 FLOOR WALL STERN- WILLIAMS AMERICAN STANDARD MTB -2424 #8344.112 SUPPLIED AND INSTALLED BY L.L. © PLUMBING FIXTURE NOTE I.) REFER TO PLUMBING SPECIFICATIONS SHEET FOR ADDITIONAL INFORMATION. GENERAL NOTES FOR NEW TOILET ROOMS: I.) ANY EXPOSED PLUMBING SHALL BE WRAPPED w/ HANDICAPPED APPROVED WHITE VINYL DRAIN COVERS SUPPLIED AND INSTALLED BY G.G. 2.) REST ROOM VINYL TILE ON FLOOR SHALL COMPLY TO FED. SPEC. L- F -4 (3) TYPE II GRADE A. 3.) IN ADDITION, CLASS 'A' MARLITE F.R.P. UP TO 48" A.F.F. - COLOR = WHITE USE MATCHING MARLITE EDGINGS 4 CORNERS. SEAL PERIMETER OF F.R.P. W/ CLEAR SILICONE SEALANT. TYPICAL FOR ALL INTERIOR TOILET ROOM WALLS. 4.) PROVIDE NON - COMBUSTIBLE FRT IN WALL BLOCKING, IN ALL LOCATIONS OF EQUIPMENT AND ACCESSORIES REQUIRED TO BE WALL MOUNTED. 5.) REFER TO ACCESSIBLE ACCESSORY INSTALLATION DIAGRAMS THIS PAGE FOR ALL TOILET ROOM ACCESSORY INSTALLATION. --- �_.-- — — HC TOILET ROOMS CC -4 MISC. BABY CHANGING STATION KOALA X 2 SUPPLIED BY TENANT VENDOR INSTALLED BY TENANT G.G. CC -5 MISC. CLOTHING HOOK PUCKS FIXTURE VENDOR X 5 SUPPLIED BY TENANT VENDOR INSTALLED BY TENANT G.G. CC-7 MILLWORK LOCKING TOILET ROOM WALL CABINET MILLSHOP X 2 SUPPLIED BY TENANT VENDOR INSTALLED BY TENANT G.G. to ACCESSIBLE INSTALLATION DIAGRAMS DISPOSAL =W) 'KOALA' BRAND ,LL MTD. FOLD )WN FURN. BY \IANT INST. BY G.G., E DETAIL 8/A5.I G. TO USE CLEAR \ULK AROUND 7RNER SHELF 4 -IANGING STATION G.G. TO CLEAR CAULK AROUND MIRROR (NEW) PAPER TOWEL HOLDER MIRROR LAVATORY INSULATE HOT WATER FRP -I PT -2 t F -3 TOILET ROOM ELEVATION SCN.e va' SCALE 1/4 - T-c" PT -2 BABY GNAN&INS STATION 0 I N FRP -I J 4 DRAIN LINES TO PROTECT AGAINST CONTACT. NO SHARP OR ABRASIVE SURFACES UNDER LAV. TOILET ROOM ELEVATION -3 AGGESSIBLE TOILET PAPER LIGHT ACCESSIBLE 50AP HAND DUPLEX DISPENSER SWITCH CONTROLS DISPENSER TOWEL RECEPTACLE DISPENSER B.O. GLG. 8' -O" A.F.F. T.O. FRP 4' -O" A.F.F. \ 0 B.O. GLG. 8' -O" A.F.F. (NEW) CABINET T.O. FRP \ 4' -O" A.F.F. GRAB BAR 9 (NEW) WATER CLOSET • El 9 ►n \D.P. < FRP -I F -3 PT -2 \P -2 • - DP TOILET ROOM ELEVATION sCALB 1/4' PT -2 FRP -I F -3 B.O. GLG. 8' -O" A.F.F. T.O. FRP 4' -0" A.F.F. \ O 9 zo TOILET ROOM ELEVATION SCAL 1/4' \ \ \DP (NEW) CABINET (NEW) PAPER TOWELHOLDER GRAB BARS (NEW) WATER CLOSET (NEW) 'KOALA' BRAND WALL MTD. FOLD DOWN FURN. BY TENANT INST. BY G.G., SEE DETAIL 8/A5.1 G.G. TO USE CLEAR CAULK AROUND CORNER SHELF 4 CHANGING STATION z_ I F -3 MAXIMUM BOWLI DEPTH 6 1/2" I I 30" MIN LAVATORY PLAN scare 1/4' - T-o BABY GHANSING STATION \l PT -2 PT -2 FRP- as n FRP -I F -3 TOILET ROOM ELEVATION TOILET ROOM ELEVATION SCAL V4' -1-U' X z - � RI N \ \ \ B.O. GLG. -0 G.G. TO CLEAR CAULK AROUND MIRROR T.O. FRP 4' -0" A.F.F. MIRROR 9 LAVATORY RI B.O. GLG. 8' -O" A.F.F. INSULATE HOT WATER 4 DRAIN LINES TO PROTECT AGAINST CONTACT. NO SHARP OR ABRASIVE SURFACES UNDER LAY. T.O. FRP 4' -0" A.F.F. \ 0 dJ 9 MAXIMUM BOWL DEPTH 6 /2" O d3 \ MIN. LAVATORY SECTION z S J / MIN KNEE GL.- �II MAX TO= GLR. I (NEW) GOAT HOOK FIXTURE (2) (NEW) VERT. GRAB BAR GRAB BARS HAND OPERATED WRIST BLADE STYLE FAUCET ALL EXPOSED PIPING TO BE INSULATED (NEW) TOILET PAPER HOLDER n - SURFACE MO PAPER DISP. CONTINUOUS I 12" )NT TOILET SHALL PERMIT ' APER FLOW PT -2 F -3 LAVATORY 4 MIRROR ELEV. B.O. G LG. 1 8' -O " A.F.F (NEW) VERT. GRAB BAR T.O. FRP 4' -0" A.F.F. \ GRAB BARS �- • (NEW) Q TOILET d PAPER t HOLDER TOILET ROOM ELEVATION SCALB V4' - r- PT-2 FRP -I F -3 TOILET ROOM ELEVATION sCAL : va' -1-o - TOILET ROOM SY LANDLORD UNDER LANDLORD PERMIT. - REVISED LAYOUT FOR FOR CLEAR FLOOR SPACE REQUIREMENTS AT WATER CLOSET B.O. GLG. 8' -0" A.F.F. (NEW) GOAT HOOK FIXTURE (3) T.D. FRP 4' -6" A.F.F. 9 9 dJ FLOOR MOUNT WATER CLOSET ELEV. - REVISED FOR FRP TO A HEIGHT OF 48" A.FF. KOALA CHANGING STATION INSTALL Si TENANT G.G. 8 - P-0" ACCESSIBILITY SIGNS PER DETAILS "A" ABOVE in ?" MIN g" MAX 36" FLOOR MOUNT WATER CLOSET ELEV. 14' -l" JG J HAND OPERATED FLUSH CONTROL OPEN SIDE X I ADA REQUIREMENTS RESTROOM SIGNAGE PER GENDER ACCESSIBLE SIGN DETAILS 8Ca-EI V4' 4-0' 3' -5" GB l' -o" 533 rY / \ / / N. L / ACCESSIBILITY SIGNS PER DETAILS "A" ABOVE CUSTOMER CARE TOILET ROOM / HC TOILET ROOM PLANS SCALE: Vr - V-o" MITE KOALA CHANGING STATION INSTALL BY TENANT G.G. REVIEWED ' R ODECOMPLIA CE APPROVE JAN 0 6 20 CityofTu la UILDING DIVI Ifli� RECEIVED CITY OF TUKWILA DEC 2 2 2009 PERMIT CENTER DATE: JOB NO: DRAWN: CHECKED: 11/15/09 STAFF KB DEC 0 8 2009 W 0 - CC cc W 0 Z r Cn W 00 CC U 0) d. Q • WOQ U �J I O : U � O Cn r �-' Cn KENNETH L. BUTTS ARCHITECT AIA 124 STAGECOACH ROAD BELL CANYON, CA 91307 (818) 999 -4272 REGISTERED RCHITECT (ADDTzri D• E • S • 1 • G• N 225 OAKLAND RAOD, SUITE 105 1PL (860) 183 -5610 scum awscR, CT 06014 FAX (860)183-5680 STORE NUMBER %TBD REVISIONS '4' ISSUE: LANDLORD COMMENTS DATE: 12/7/09 'B' - ISSUE DATE 'C'- ISSUE DATE 'p' -ISSUE DATE SHEET TITLE N - 0 G l0 ta .C1 H.C. CUSTOMER CARE AREA PLAN AND ELEVATIONS SCALE AS NOTED SHEET NUMBER A3.3 TOTAL AREA 4,000 Sq. Ft. STOCKROOM /OFRCE MARK TYPE DESCRIPTION MFG. / SUPPLIER OTY REMARKS SE-1 MISG. EMPLOYEE BREAK TABLE OFFICE SUPPLY VENDOR I SUPPLIED BY VENDOR SE-2 MISO. MICROWAVE OFFICE SUPPLY VENDOR I SUPPLIED BY VENDOR SE-3 MISC. REFRIGERATOR OFFICE SUPPLY VENDOR I SUPPLIED BY VENDOR SE-4 METAL LOCKERS OFFICE SUPPLY VENDOR I BY VENDOR, ATTACH TO WALL SE-5 METAL FLOOR SHELVING VENDOR 6 SUPPLIED BY VENDOR SE-6 METAL ROLLING SAFETY LADDER VENDOR I NOT SHOWN IN PLAN SE-7 MISC. DRY ERASER BOARD OFFICE SUPPLY VENDOR I SUPPLIED BY VENDOR SE-8 MISG. WALL MOUNT CLOCK OFFICE SUPPLY VENDOR 2 OFFICE AND STOCK AREA, SUPPLIED BY VENDOR SE-9 MILLWORK HARDWARE BIN MILLSHOP I SUPPLIED BY VENDOR SE MILLWORK MANAGER'S DESK MILLSHOP I SUPPLIED BY VENDOR, ADD GROMMETS SE 11 MISG. FRAMED CORK BRD. OFFICE SUPPLY VENDOR 2 SUPPLIED BY VENDOR SE-12 MILLWORK I8" W ROLLED CORK BRD. MILLSHOP I SUPPLIED BY VENDOR SE-13 METAL (4) DRAW FILE CABINET OFFICE SUPPLY VENDOR I SUPPLIED BY VENDOR SE-14 METAL (2) DRAW FILE CABINET OFFICE SUPPLY VENDOR I SUPPLIED BY VENDOR SE -15 METAL SAFE OFFICE SUPPLY VENDOR I SUPPLIED BY VENDOR COUNTER SECTION SCALE T4-0' T SCALE 1/4•4 -0' PT -2 SE-8 4' -3" 4' -5" SE-11 CORK BOARD B2 OFFICE ELEVATION COMPUTER Ll B.O. CEILING IO' -O" A.F.F. O I O PLAM zo I 2' -O" 3/4" WHITE PLAM. (PL- I) I -I/8" WHITE (PLAM, EB) O I d- ROLLED CORK N PT -2 (2) QUAD REGPT. (I) DATA, (I) .1-SOX OFFICE ELEVATION SCALE V4'4-0' B.O. CEILING 10' -0" A.F.F. (4) 12 "D X ciS" L PLAM. SHELF. EDGE BANDED GUT TO FIT 24 "D X 48 "L PLAM. GOUNTEP PLAM. SHELF SUPPORTS QUAD REGPT. 0 J -BOX SPK ! WIRES O (I) DEDICATED QUAD REGPT. (I) QUAD (I) DATA W/ 3 PORTS ENS UM MSS EMI SCALE vr--O' 1 = 1 eats O SE-15 SCALE V4'4-o' T.O. STANDARD 4' SURFACE MOUNTED STANDARDS 12" WOOD SHELF BRACKET OFFICE DESK ELEVATION PT -2 1 ' ,....- 4' -5"_ B2 B.O. STANDARD N OFFICE ELEVATION B.O. CEILING 10' -0" A.F.F. 2' -O" SHELF MOUNTED AT 5' -6" A.F.F. SUPPLIED AND INSTALLED BY G.G. O I O REAR ANCHOR CLEAT SCALE T4-0' 2' -O" OPEN BACK COUNTER SECTION PT -2 SE-13 52 SCALE I/4'4 -0' INTERIOR ELEVATION SCALE ¥4• -T-o' OFFICE ELEVATION PT -2 t B2 SUPPORT LEDGER B.O. CEILING IO' -O" A.F.F. 9 O T.O. PAINT 14' -O" A.F.F. T.O. STNDS 12' -3" A.F.F. B.O. STNDS 2' -3" A.F.F. B.D. DECK 21' -II I /2" A.F.F. T.O. PAINT 14' -0" A.F.F. T.O. STNDS I2' -3" A.F.F. 9 O B.O. STNDS 2' -3" A.F.F.= N PT2 D9'OR 4 / - � R B IM i�r t 1 n PT -2 52 8CaB114''4-0' EXTENTS OF FRP AT MOP SIN FRP -I INTERIOR, BACK, SIDES AND FRONT r SE-4 ,® 1® REF. 3C 3 EMPLOYEE LOCKERS BOLTED TO WALL INTERIOR ELEVATION CORK BOARD PT -2 SE-8 SE ft BREAK TABLE SE-1 B2 IN ' I S ' ELEVATION SCALE SE-2 MIC. 1* I B.O. DECK 21' -II 1/2" A.F.F. T.O. PAINT 14' -O" A.F.F.= tr T.O. STNDS I2' -3" A.F.F. 9 O B.O. STNDS 2' -3" A.F.F.= N N ti B.O. DECK 21' -II 1/2" A.F.F. NEW PANELS AND TRANS. BY L.L SCALE 1I4'4 -0' PT -2 \PT2 INTERIOR ELEVATION B2 B.O. DECK 21' -II 1/2" A.F.F. T.O. PAINT 14' -0" A.F.F. 9 PT -2 52 INTERIOR ELEVATION SCALE 1/4 4r (I) J -BOX (I) IG DUPLEX REGPT. 2'X3' PLYWOOD BACKBOARD FOR SECURITY EQUIPMENT SCALE V4• -T-0' B2 PT -2 ■ ET2 INTERIOR ELEVATION B.D. DECK 21' -II 1/2" A.F.F. T.O. PAINT I4' -0" A.F.F.= tr T.O. STNDS - 12' -3" A.F.F 9 0 B.O. STNDS 2' -3" A.F.F.= N " B. DECK 21' -II 1/2" A.F.F. T.O. PAINT 14' -O" A.F.F. 9 REVIE�VE ' NCE C ODE COM APPROVED J AN 0 6 2010 C ity of T BUILDING DI if oRgi • SE-13 r;'_,. i • • • r 4 i NEI 0 0 0 4/ SE-11 'OFFICE 104 73 SO /1T -2x //\ EEO N,I / 8 ' - D " 0 0 Q I ® SE14 7 STOCK ROOM 105 396 SO/FT= 10X KEY PLAN SCALE V4• -T-0• CITY OF TUKWILA DEC 2 2 2009 PERMIT CENTER DATE: JOB NO: DRAWN: CHECKED: 34 5 DEC 0 8 2009 I I/15/09 09 -066 STAFF KS / W 0 - CC cc W oo r O ^ z M � V,W00 D • NOQZ O ( I V 0 "D ci C0 KENNETH L. BUTTS ARCHITECT AIA 124 STAGECOACH ROAD BELL CANYON, CA 91307 (818) 999 -4272 11 . 1 !4 REGISTERED TECT KEN ETH L. BUTTS STATE OF WASHINGTON CADD D• E • • I • G• N 225 OAKLAND RAOD, SUITE 105 TEL: (860) 183 -5610 SCUM WINDSOR, CT 06014 FAX (860)183 -5680 SHEET TITLE SCALE NOTED SHEET NUMBER A3.4 STORE NUMBER #TBD REVISIONS '4 ISSUE: LANDLORD COMMENTS DATE: 12/1/09 'B'- ISSUE DATE 'C'- ISSUE DATE 'D'- ISSUE DATE STOCKROOM AND OFFICE ELEVATIONS 3 5/8" X 200A RUNNER TRACK SECURED TO WALL STUDS BOBRIGK MOP HANGER #B223X24, MOUNT OVER SINK BY G.G. PROVIDE IN WALL BLOCKING FOR FAUCET 3 5/8" X 20 GA METAL STUDS 0 8" D.G. WITH 5/8" MO ISTURE RESISTANT GYP. P. TYPE "MR" GYP. BD. AND FRP FINISH TO UNDERSIDE OF HATER HEATER PLATFORM 3' LONG MOP SINK HOSE BY G.G. MOP SINK 3 5/8" X 20GA TRACK CONT INUOUS (2) #I SCREWS TO EA. METAL STUD SECURED TO SLAB 9 dJ WATER HEATER RETAIL 10' -0" A.F.F. ACOUSTICAL CEILI T.O. STANDARD q' -O" A.F.F. 8' GARGY #1204 SURFACE MOUNTED STANDARDS @ 24" O.G. G.G. TO SUPPLY AND INSTALL WITH HILTI TOGGLERS #00314508 12" O.G.. VERTICALLY B.O. STANDARD 1' -0" A.F.F. FLOOR ELEV T.O. STANDARD 12' -3" A.F.F. 10' GARGY #1204 SURFACE MOUNTED STANDARDS @ 36" O.G. G.G. TO SUPPLY AND INSTALL WITH HILTI #00314508 TOGGLERS 12" O.G.. VERTICALLY 6" X I BGA METAL STUDS ® 16" O.G. 5/8" TYPE "X" GYP. BD. FULL HEIGHT STOCK SIDE B.O. STANARD 2' -3" A.F.F. B.O. ACT. GLG. 10' -0" A.F.F. 6" X I 8GA METAL STUDS © 16" O.G. 5/8" TYPE "X" GYP. BD. FULL HEIGHT STOCK SIDE OFFICE 6" X 18GA (EXISTING) BUILT UP ROOF SYSTEM RIGID INSUL. AND MEMBRANE ROOF OVER METAL DECK, AND STRUCTURE STEEL BAR JOISTS. TRACK CONTINUOUS (2) #I0 SCREWS TO EA. METAL STUD SECURED TO SLAB W/ POWDER AGUTATED FASTENERS Imo\ r \ 0 / WALL SECTION BCALBT -T -O (EXISTING) BUILT UP ROOF SYSTEM RIGID INSUL. AND MEMBRANE ROOF OVER METAL DECK, AND STRUCTURE STEEL BAR JOISTS. 182141 1E1:21 L WALL SECTION 1 L. TRACK TO DECK 3 5/8" X 2OGA RUNNER TRACK SECURED TO WALL STUDS B.O. DECK 1' -O 3 5/8" X 2OGA METAL STUDS 4 AND RUNNER TRACKS 8" O.G. 5/8" MOISTURE RESISTANT GYP. BD. BOTH SIDES AND 3/4" FRT PLYWOOD DECK FOR WATER HEATER FRP -I FINISH AT INTERIOR FRP FINISH INSERT 6" TRACK BLOCKING 0 - 0 " FLOOR ELEV 0' -0" O r B.O. ROOF DECK 0 23' -q" TO 21' -I1 Y2" A.F.F. GYP. BD. TO 6" ABOVE CEILING ON SALES SIDE B.O. ACT. GLG. 9- i m m i N 6" X 18GA METAL STUDS 0 16" O.G. 5/8" TYPE "X" GYP. D. FULL HEIGHT STOCK SIDE 6" X IBGA TRACK CONTINUOUS (2) #10 SCREWS TO EA. METAL STUD SECURED TO SLAB W/ POWDER AGUTATED FASTENERS 6" X 18GA STOCK ROOM STOCK ROOM TRACK CONTINUOUS (2) #I SCREWS TO EA. METAL STUD SECURED TO SLAB W/ POWDER AGUTATED FASTENERS SCALE T - T -o' (EXISTING) BUILT UP ROOF SYSTEM RIGID INSUL. AND MEMBRANE ROOF OVER METAL DECK, AND STRUCTURE STEEL BAR JOISTS. 0 L rat) MU WA IMM WALL SECTION 6' X 180 ' TRACK ONTINUO. TO NDESIDE v. DECK I WALL SECTION 8CAL8 T - T-O• ACOUSTICAL GEILING HALL OFFICE (EXISTING) BUILT UP ROOF SYSTEM RIGID INSUL. AND MEMBRANE ROOF OVER METAL DECK, AND STRUCTURE STEEL BAR JOISTS. TRACK TO DECK ACOUSTICAL CEILING 8' GARGY #1204 SURFACE MOUNTED STANDARDS @ 24" O.G. G.G. TO SUPPLY AND INSTALL WITH HILTI TOGGLERS #00314508 12" O.G.. VERTICALLY RETAIL INSERT 6" TRACK BLOCKING INSERT 6" TRACK BLOCKING B.O. ROOF DECK 0 23' -1" TO 21' -II Y2" A.F.F. GYP. BD. TO 6" ABOVE CEILING ON SALES SIDE B.O. ACT. GLG. 10' -0" A.F.F. FLOOR ELEV 0' -D" B.O. ROOF DECK 25' -q" TO 21' -I1 Y2" A.F.F. GYP. BD. TO 6" ABOVE GEILING ON SALES SIDE B.O. ACT. GLG. 10' -0 " A.F.F. T.O. STANDARD q -O " A.F.F. B.O. STANDARD 1' -0" A.F.F. FLOOR ELEV 0' -O" O 9 dJ 9- i 0 O EXISTING BAR JOISTS INHERE THEY OCCUR TOP OF INTERSECTION PARTITION BEYOND GOUSTICAL CEILING 3 5/8" X 2OGA METAL STUDS @ 16" O.G. 5/8" TYPE "X" GYP. BD. OFFICE 3 5/8" X 2OGA TRACK CONTINUOUS (2) #1 SCREWS TO EA. METAL STUD SECURED TO SLAB 6" X IBGA TRACK CONTINUOUS TO UNDESIDE OF DECK FULL HEIGHT IHR RATED DEMISING WALL: 6" X IBGA METAL STUDS @ 16" D.G. W/ SOUND BATT INSULATION AND 5/8" TYPE "X" GYP. BD. FULL HEIGHT TO UNDERSIDE OF DECK TENANT SIDE PER UL DESIGN U -465 ADJACENT TENANT 6" X 18GA TRACK CONTINUOUS (2) #10 SCREWS TO EA. METAL STUD SECURED TO SLAB W/ POWDER AGUTATED FASTENERS r I L (EXISTING) BUILT UP ROOF SYSTEM RIGID INSUL. AND MEMBRANE ROOF OVER METAL DECK, AND STRUCTURE STEEL BAR JOISTS. ?MI IPMS — P WALL SECTION 8CALE' T - T-O• 136531 02331 MI ISM 3 5/8" X 205A METAL TRACK WITH #1 SCREWS CH SIDE TO EA. STUD (EXISTING) BUILT UP ROOF SYSTEM RIGID INSUL. AND MEMBRANE ROOF OVER METAL DECK, AND STRUCTURE STEEL BAR JOISTS. SCALE: T - T-O• WALL SECTION n PARTITION TO 6" ABOVE CEILING ACOUSTICAL CEILING HALL 10' -0" A.F.F. ACOUSTICAL CEILING B.O. ROOF DECK T.O. PARTITION 10' -6" A.F.F. B.O. ACT. GLG. 10' -0 " A.F.F. FLOOR ELEV 0' -0" B.O. ROOF DECK 23' -q" TO 21 Y2" A.F.F. EXISTING BAR JOISTS WHERE THEY OGGUR B.O. ACT. GLG. T.O. STANDARD q -O" A.F.F. 8' GARGY #1204 SURFACE MOUNTED STANDARDS @ 24" O.G. G.G. TO SUPPLY AND INSTALL WITH HILTI TOGGLERS #00314508 12" O.G.. VERTICALLY RETAIL B.O. STANDARD 1' -0" A.F.F. 23' -q" TO 21' -II Y2" A.F.F. 9 i O 9 c0 9 FLOOR ELEV 0' -O" z 0 O O dJ B.O. ACT. GLG. 8 ' -O" A.F.F. 6" X 18GA METAL STUDS © 16" O.G. 5/8" TYPE "X" GYP. BD. FULL HEIGHT STOCK SIDE TOILET ROOM 6" X IBGA TRACK CONTINUOUS (2) #10 SCREWS TO EA. METAL STUD SECURED TO SLAB W/ POWDER AGUTATED FASTENERS EXISTING TRACK TO STRUCTURE ABOVE EXISTING 3HR RATED DEMISING WALL: METAL STUDS @ 16" O.G. W/ SOUND BATT INSULATION AND (5) LAYERS OF 5/8" TYPE "X" GYP. BD. FULL HEIGHT TO UNDERSIDE OF DECK BOTH SIDES PER UL DESIGN U -41q ADJACENT TENANT EXISTING TRACK TO SLAB (EXISTING) BUILT UP ROOF SYSTEM RIGID INSUL. AND MEMBRANE ROOF OVER METAL DECK, AND STRUCTURE STEEL BAR JOISTS. �I 6 ' X 18G ^ TRACK 1.:1÷ ` \ ONT1NUO� TO i , �NOESIDE •• DECK I WALL SECTION SCALE. T - TAT (EXISTING) BUILT UP ROOF SYSTEM RIGID INSUL. AND MEMBRANE ROOF OVER METAL DECK, AND STRUCTURE STEEL BAR JOISTS. WALL SECTION SCAB 1 -T-O' RETAIL INSERT 6" TRACK BLOCKING 1- L ACOUSTICAL CEILING' RETAIL B.O. ROOF DECK 23'- 1" TO 21' -II Y2" A.F.F. GYP. BD. TO 6" ABOVE CEILING ON SALES SIDE B.O. ACT. GLG. 10' -O" A.F.F. ACOUSTICAL CEILING T.O. STANDARD q' -O" A.F.F. 8' GARGY #1204 SURFACE MOUNTED STANDARDS © 24" D.G. G.G. TO SUPPLY AND INSTALL WITH HILTI TOGGLERS #00514508 12" O.G.. VERTICALLY B.O. STANDARD I' -O" A.F.F. FLOOR ELEV 0' -0" B.O. ROOF DECK 0 25' -q" TO 21' -I1 Y2" A.F.F. EXISTING BAR JOISTS WHERE THEY OCCUR B.O. ACT. GLG. 10' -0" A.F.F. T.O. STANDARD 1' -O" A.F.F. 8' GARGY #1204 SURFACE MOUNTED STANDARDS @ 24" O.G. G.G. TO SUPPLY AND INSTALL WITH HILTI TOGGLERS #00314508 12" O.G.. VERTICALLY RECEIVED CITY OF TUKWILA DEC 22 2009 PERMIT CENTER B.O. ST I' -O" A. FLOOR 0' -O 9 O i 9 9 REVIEWED FOR IODECOMPLIANCE F. APPROVE JAN 0 6 21310 ELEV City of Tukwila BUILDING DIV SIDN DATE: 11/1/09 JOB NO: 09 -066 DRAWN: STAFF CHECKED: KB KENNETH L. BUTTS ARCHITECT AIA 124 STAGECOACH ROAD BELL CANYON, CA 91307 (818) 999 -4272 3405 REGISTERED AR .H O Vb- ENNETH L. BUTTS STATE OF WASHINGTON (ADDTE(11 D• E • S• I • G• N 225 OAKLAND RAOD, 5U11E 105 TEL: (860) 183-5610 SOUTH WPb50R, CT 06014 PAX: (860)183-5680 DEC 0 8 2009 " W CC cc W oo �Z� W� W ��� Z T D • I A 0 <C2 Y 0 N rH(n 3i) CD 4-0 14 MI ' L V STORE NUMBER SHEET TITLE %TBD REVISIONS 'A'- ISSUE: LANDLORD COMMENTS DATE: 12/7/09 'B' -ISSUE DATE 'C'-ISSUE DATE 'D' ISSUE DATE INTERIOR SECTIONS SCALE r - r-o• SHEET NUMBER A4.1 VERTICAL STRUT SCHEDULE EMT CONDU 1/2" EMT CONDUIT UP TO 5' -10" 3/4" EMT GONDUIT UP TO 1' -8" I" EMT CONDUIT UP TO '1' -Q" METAL STUDS SINGLE 1 5/8" MTL. STUD (20 GA.) UP TO 12' -0" BACK TO BAGK 1 5/8" MTL. STUD (20 GA.) UP TO 15' -0" SINGLE 2 1/2" MTL. STUD (20 GA.) UP TO 13' -6" BAGK TO BACK 2 1/2" MTL. STUD (20 GA.) UP TO 15' -0" CEILING HOOK ASSEMBLY FROM MERGHANDISING INVENTIVES ITEM #1510L AND #151OR (4 EA. REQUIRED PER GRID SUSPENDED ACOUSTICAL GE IL ING "5" HOOK FROM "MERGHANDISING INVENTIVES" ITEM #1045RI.10 GALVANIZED DOUBLE G -HOOKS LENGTH AS REQUIRED FOR HEIGHT "MERCHANDISING IVENTIVES" AVAILABLE 4" - 36" LONG GRAPHIC HANGING SYSTEM TO BE UTILIZED EXISTING STRUCTURE: STEEL BAR JOISTS, WITH BUILT UP ROOF SYSTEM METAL DECK, RIGID INSUL. AND MEMBRANE ROOF IBGA DEEP LEG SLIP TRACK WITH #10 SCREWS AT EACH STUD EACH SIDE UPPER MOST PUNCH -OUT SCALE 3• - T -0• 0I I' -6" 0 1 I 0 C PVC DRAWING HOLDER DETAIL 12 SCALE NITS I'X WI I TE TRACK TO DECK DETAIL 4" PVC GLEANOUT PLUG 4" PVC PINY GLEANOUT ADAPTER 4" 2 -HOLE PVG CLAMP 4 "X30 "L PVG PIPE AT ON BACKER BOARD O FRTPLAYWOOD BACKER m BOARD PAINTED 4" 2 -HOLE PVG CLAMP 4" PVG GAP SLIP 12" WHITE WIRE GRID �ANEL, H 3" SOS, FROM EC ONOGO � # G1N15 :::szs o9',so • r yere,:���o °� v°.�: %.• a °OAS °. o° �a��° .g: °:s °. ° � a.F°.� °.° vy®'�`��eo:.°?.�*:* ►�1� l • TRACK LIGHTING STOREFRONT DISPLAY WINDOW STOREFRONT POSTER GRID INSTALL DETAIL SCALE 1 Vr - T-o' ' -� 18GA TRACK TO DECK WITH (2) #IO SCREWS TO EACH FLUTE 0 48" O.G. GYP. BD. PER SECTION DEFLECTION GAP FIRE SAFE INSULATION IN DECK FLUTES AT RATED PARTITIONS METAL STUDS PER SECTION HORIZ. BRIDGING: 1 1/2" GOLD ROLLED CHANNEL CONTINUOUS SECURE TO EA. 16" 0.G. STUD W/ 2" X 2" X 16GA CLIP ANGLES (2) #IO PWH SCREWS EA. GONNEC1 PER STUD MANUFACTURES REQUIREMENTS EXISTING STRUCTURE. STEEL BAR JOISTS, WITH BUILT UP ROOF SYSTEM METAL DECK, RIGID INSUL. AND MEMBRANE ROOF IBGA DEEP LEG SLIP TRACK WITH #10 SCREWS AT EACH STUD EACH SIDE UPPER MOST PUNCH -OUT GYP. BD. PER SECTION ACOUSTGAL CEILING SEISMIC. SPLAY WIRES ARE TO BE FOUR 12 GAGE WIRES ATTACHED TO THE MAIN BEAM. WIRES ARE ARRAYED ci0 DEGREE'S FROM EACH OTHER AND AT AN ANGLE NOT EXCEEDING 45 DEGREES FROM THE PLANE OF THE CEILING. 12 GUAGE SESMIG SPLAY WIRES WITH 4 TIGHT TURNS IN 1 1/2" - TYP. TOP BOTTOM SPLAY WIRES ARE TO BE WITHIN 2" OF CONNECTION OF THE VERTICAL STRUT TO SUSPENDED CEILING. SCALE r - T -o• SCALE 3• - T-Q SCALE 3• - T-0• LATERAL FORGE BRACING SHALL BE 12' O.G. MAX. AND BEGIN NO FURTHER THAN 6' FROM WALLS PER SCHEDULE ABOVE TRACK TO DECK DETAIL TOP TRACK DETAIL A TRACK TO SLAB DETAIL GROSS RUNNER SCALE: N TS CONCRETE SLAB NOTES: I. ALL WIRE CONNECTIONS MINIMUM 3 TURNS IN 1 1/2" FOR 12 GA WIRE, 3 TURNS IN 3" FOR I GA WIRE, TYPICAL 2. MINIMUM 1/8" LEDGE ANGLE AT PERIMETER 3. INCLUDE SPACE BARS OR OTHER SUITABLE SYSTEM, SUCH AS RETENTION CLIPS OR POP RIVETS, TO KEEP PERIMETER COMPONENTS FROM SPREADING APART 4. RUNNER SYSTEM TO HAVE INTEGRAL GROSS /MAIN RUNNER CLIPS, IF NO INTEGRAL CLIPS PRESENT, PROVIDE MANUF. STD. SEISMIC LOCKING CLIP OR PIN AT GROSS/MAIN RUNNER INTERSECTIONS 5. APPROXIMATELY 45 DEGREE SPLAY WIRES TO ALL BE ATTACHED TO MAIN RUNNER 6. BRACING TO OGGUR @ 12' -O" O.G. EACH WAY OR FOR EVERY 144 SQ. FT. OF CEILING AREA. SEISMIC BRACING DETAILS ACOUSTICAL CEILING ISOMETRIC DETAIL SCALE NTS + -45 18GA STEEL STRAPS @ 48" O.G. TO (2) DECK FLUTES WITH (2) #IO SCREWS TO EACH FLUTE METAL STUDS PER SECTION HORIZ. BRIDGING: I 1/2" GOLD ROLLED CHANNEL CONTINUOUS SECURE TO EA. 16" O.G. STUD W/ 2" X 2" X I6GA CLIP ANGLES (2) #IO PWH SCREWS EA. CONNEGTIOP PER STUD MANUFACTURES REQUIREMENTS 20 GA TRACK PER SECTION DETAIL AGOUSTGAL CEILING MTL. STUDS PER SECTION METAL STUDS AT 16" O.G. W/ GYPSUM BOARD PER SECTION DETAIL 20 GA. MTL. TRACK PER SECTION DETAIL + -45 MAX. 'SECTION' HILTI X -ZF # 32 P8/36M (0.145" SHANK DIA) FASTENERS © 16" O.G. (OR EQUAL) VERTICAL STRUGT BRACING PER SCHEDULE 12 GA. OR HEAVIER HANGER WIRES 012' -0" O.G. EACH WAY + -45 + -45 MAIN RUNNER 9 + -45 B.0. ACT. GLG 8' -0" A.F.F. MAX. 'PLAN' 12 GUAGE VERTICAL HANGER WIRES @ 4' -0" O.G. EACH WAY WITH 3 TIGHT TURNS IN 1 1/2" - TYP. TOP /t BOTTOM MAIN RUNNERS 3 5/8" X 20GA METAL TRACK WITH #IO SCREWS EACH SIDE TO EA. STUD ACOUSTICAL CEILING 3 5/8" X 20GA METAL STUDS © 16" O.G. 5/8" TYPE "X" GYP. BD. TOILET ROOM 5 5/8" X 20GA TRACK CONTINUOUS (2) #10 SCREWS TO EA. METAL STUD SECURED TO SLAB GROSS RUNNER MAIN RUNNER GROSS RUNNERS SCALE T - T-0• WALL SECTION HANGER WIRE FOR CEILING AREAS EXGEEEDING 2500 SQ /FT, A SEISMIC SEPARATION JOINT SHALL BE PROVIDED. SEE CEILING PLAN FOR JOINT LOCATION. SUSPENDED CEILING GRID / SEISMIC SEPARATION JOINT SCALE M8 • SUSPENDED CEILING GRID / UNATTACHED WALL MOLDING SCALE M8 SCALE Nib NOTE: U5 HEAVY DUTY GRID AS REQUIRED ::11"x":":::"" ":"::1111 1 1111""""1111" 1111 1 1111 1 1111""1111""" 1111 1 1111 HALL * o I I .. o Qa 3� MIN 8 MAX GAP 2 , CLOSURE ANGLE METAL STUDS PER SECTION " AX MAIN "TEE" CLOSURE ANGLE / METAL STUDS PER SECTION PARTITIONS TO 6" ABOVE CEILING 2" (EXISTING) BUILT UP ROOF SYSTEM RIGID INSUL. AND MEMBRANE ROOF OVER METAL DECK, AND STRUCTURE STEEL BAR JOISTS. NOTE: US HEAVY DUTY GRID AS REQUIRED MAIN "TEE" NOTE: U5 HEAVY DUTY GRID AS REQUIRED MAIN "TEE" SUSPENDED CEILING GRID / FIXED WALL MOLDING B.O. ROOF DECK 25 TO 21' -II Y2" A.F.F. T.O. PARTITION 10' -5" A.F.F. B.O. ACT. GLG. 10' -0" A.F.F. FLOOR ELEV O' -O• TS O O N T L TOP OF INTERSECTING PARTITION BEYOND 6" X 20GA TRACK CONTINUOUS (2) #10 SCREWS TO EA. METAL STUD ACOUSTICAL CEILING 8' -0" @ TOILET ROOM 6" X 20GA METAL STUDS @ 16" O.G. WITH 5/8" TYPE "MR" GYP. BD. TOILET ROOM 6" X 20GA TRACK CONTINUOUS (2) #10 SCREWS TO EA. METAL STUD SECURED TO SLAB MAIN RUNNER VERTICAL STRUT © 8' -0" X12 O.G. MINIMUM - SEE DETAIL 10/A4.3 FIXTURE NI VERTICAL HANGER WIRE 0 EA. CORNER CONNECTED TO STRUCTURE ABOVE NOTES: I. A HEAVY DUTY T -BAR GRID SYSTEM MUST BE USED. • 2. THE MAIN AND GROSS RUNNERS SHALL BE TIED TOGETHER TO PREVENT TWISTING. 3. ALL WIRE CONNECTIONS MINIMUM 3 TURNS IN 11/2" FOR 12 GA WIRE, 3 TURNS IN 3" FOR ci GA WIRE, TYP. 4. SPRINKLER HEADS AND OTHER PENETRATIONS OF THE SUSPENDED CEILING SHALL HAVE A 2" OVERSIZE RING, SLEEVE, OR ADAPTOR THROUGH THE CEILING TILE TO ALLOW FOR FREE MOVEMENT OF AT LEAST I" IN ALL HORIZONTAL DIRECTIONS. 5. IF SUSPENDED CEILING EXCEEDS 2500 SF, THERE SHALL BE A SEPARATION JOINT OR A FULL HEIGHT WALL PARTITION SEPARATING THE SUSPENDED CEILING INTO AREAS LESS THAN 2500 SF. SEE CEILING PLAN AND DETAIL 8G ACOUSTICAL CEILING PLAN DETAIL SCALE NTS MI REM MS 11.1 tegill Mai (EXISTING) BUILT UP ROOF SYSTEM RIGID INSUL. AND MEMBRANE ROOF OVER METAL DECK, AND STRUCTURE STEEL BAR JOISTS. WALL SECTION SCALE T -T-0• 12 GA. VERTICAL HANGER WIRE 48" 0.G. EA. WAY MINIMUM L PARTITIONS TO 6" ABOVE CEILING TOILET ROOM GROSS RUNNER SLIP JOINT B.O. ROOF DECK 23' -Q" TO 21' -II Y2 A.F.F. T.O. PARTITION 10' -6" A.F.F. ACOUSTICAL CEILING 8' -O" @ HALL T.O. PARTITION 8' -6" A.F.F. B.O. ACT. GLG. 8' -O" A.F.F. REVIEWE FOR CODE COMPLIANCE APPROVED JAN 0 6 2010 O i City of Tukwila BUILDING DlvlSlfN RECEIVED CITY OF TUKWILA DEC 2 2 2009 PERMIT CENTER FLOOR ELEV 0' -0" z4 DATE: JOB NO: 09 -066 DRAWN: STAFF CHECKED: KB 34.5 DEC 0 8 2009 • 11/1/09 W 0 - CC cc D co Q W rr Z v, V/ CC U d. Z � • W0 Uw H V D LO al OD CM KENNETH L. BUTTS ARCHITECT AIA 124 STAGECOACH ROAD BELL CANYON, CA 91307 (818) 999 -4272 1 H L. BUTTS STATE OF WASHINGTON REGISTERED CHITECT i (A DDTcz t1 D• E • S • I • G• N 215 OAKLAND RAM, SUITE 105 1EL: (860)183 -5610 SO1n4 WD'D50R,CT 06014 FAX (860)183 -5680 H - D C to STORE NUMBER %TBD REVISIONS 'A'- ISSUE: LANDLORD COMMENTS DATE: 12/1/09 'B'- ISSUE DATE 'C'- ISSUE DATE 'D'- ISSUE DATE SHEET TITLE DETALS SCALE AS NOTED SHEET NUMBER A4.2 NOTES: 1. WC DUTY WEFIKTURE STORAGE CAPACITY: NOO PER LEVEL E. BENT STEEL PLATE ASTM ANTO KIR SHAPE Fy - W00 PIE GRADE NN N. ALL BOLTS ANA (UNLESS OTIMIT MEE NOTED). 4. INSTALL (1) FNLTI IOMK BOLT N ANCHOR PER LOOT FIATS, ICC IBIIMNNN OR APPROVED OQWL. 5. CONCRETE 4• THOU GOODPM. 1/4 1 /16 2 " MIN. EMBEDMENT 0 SHELVING CONNECTION TO CONCRETE SLAB SCALE NIS OF CHANGING STATION " OVE LL WIDTH 32" 1O.G. 6" O.G. 6" O.G. I i 1 SCALE VT 1 RECI D PER FOOT PLATE NOTES: I. MOUNT BABY CHANGING STATION AS PER MANUFACTURER'S INSTRUCTIONS 2. BED HEIGHT TO BE 33" FROM FLOOR WHEN INSTALLED WITH THESE DIMENSIONS MOUNTING HOLES DASHED LINES INDICATE DOUBLE STEEL STUDS @ BABY CHANGING STATION SUPPORT - CONNECT STUDS TOGETHER 8 SECURELY ANCHOR @ TOP BOTTOM. MIN. STUD SIZE, 3 5 /8 ", 20 GA. BABY CHANGING TABLE DETAIL DASHED LINES INDICATE STEEL STUD FRAMING IN EXISTING WALL ATTACH POST TO FOOTPLATE W/ (1) EA. #10 X 5/8" SELF DRILLING SCREW HILTI TOGGLERS @ EACH HOLE OF STANDARD 10' STANDARDS @ 36" 0.G. PARTICLE BOARD SHELF SCALE 1 VT - T-O GALVANIZED STEEL END CHANNELS ADJUSTMENTS, 2" 0.G. (TYP) GALVANIZED STEEL END POST DETAIL * SHELF SPACING DETAIL A STOCKROOM HANG RODS SCALE, 1Vr -T-0' CONNECTION DETAIL (TYP.) SCALE: NM SHELVES TO BE SPACED 50 (1) SLOTS IN UPRIGHT ARE VISIBLE BETWEEN BRACKETS HANG ROD BRACKET FIRST HANG ROD TO START AT HIGHEST POSSIBLE POINT, MAINTAIN MIN. IS" BELOW CEILING OR SPRINKLER HEAD HANG RODS TO BE SPACED SO (-1) SLOTS IN STANDARD ARE VISIBLE BETWEEN BRACKETS RECTANGULAR HANG ROD IN S' LENGTHS, GUT TO FIT, USE SPLICERS AS REQUIRED. HANG ROD MAY NOT EXTEND PAST LAST STANDARD. SCALE NM HORIZONTAL BRACE DETAIL 5 /e" THICK PARTICLE BOARD BRACING, ATTACH WITH (4) Yz" DIA. BOLTS, (2) PER ENDS © 3" 0.G. NOTE: ALL PARTICLE BOARD TO BE FIRE RETARDANT 16 GA. BACK TO BACK CLIP OR #12 TEL SCREWS @ 24" O.G. (BACK TO BACK CLIP) 4 -O" TYPICAL 10' HIGH X 24" DEEP STOCK UNIT SCALE NIS SCAIr NTS 0 1 0 1 SCALE Ur - T-O' 4' -O" TYPICAL 10 STOCK UNIT CONFIGURATION TYPICAL 10' STOCK UNIT DETAIL (CUT TO FIT) 4' -O" IS GA. STEEL END CHANNEL 3 /4" THICK PARTICLE BOARD SHELF 17 GA. BACK BRACE STOCK UNIT HEIGHT 10' -O" # OF SHELVES ADJUSTMENTS AREA, 2" 0.C. TYP. GALVANIZED STEEL POST PARTICLE BOARD SHELF SHELVES TO BE SPACED 50 (5) SLOTS IN UPRIGHT ARE VISIBLE BETWEEN BRACKETS PROVIDE BENT STEEL ANGLE, EXPANSION BOLTED TO CONCRETE SLAB AND SCREWED TO VERTICAL SHELVING POST. (AT EACH POST BASE TYP. SEE DETAIL) SHELVES TO BE SPACED 50 (8) SLOTS IN STANDARD ARE VISIBLE BETWEEN BRACKETS 2'-0" bo9 2V1 REVIEWED FOR CODE COMPLIANCE APPROVED JAN 0 6 2010 City of Tukwila BUILDING DIIIIq m RECEIVED CITY OF TUKWILA DEC 2 2 2009 PERMIT CENTER DATE: 11/15/09 JOB NO: 09 -066 DRAWN: STAFF CHECKED: KB KENNETH L. BUTTS STATE OF WASHINGTON 405 KENNETH L. BUTTS ARCHITECT AIA 124 STAGECOACH ROAD BELL CANYON, CA 91307 (818) 999 -4272 REGISTERED R ITECT (ADDTzt D• E • S • I • G• 215 OAKLAND RAOD, SUITE 105 1EL (860)183-5610 SOUTH WINDSOR GT 06014 FAX (860)183 -5680 DEC 0 8 2009 STORE NUMBER %TBD REVISIONS '4' ISSUE: LANDLORD COMMENTS DATE: 12/7/09 'B' -ISSUE DATE 'G'- ISSUE DATE ' -ISSUE DATE SHEET TITLE STOCKROOM SHELVING DETALS SCALE NOTED SHEET NUMBER A5.1 in C l0 (EX) ROOF DECK (EX) BAR JOIST C4X5.4 -6" BLOCKING TO BLOCK UP CURB. 3/I6 (TYP. 4 CORNERS) 3/16 (E) ROOF DECK L4 "X4 "XX1 /4" X6" JOIST CLIPS (TYP.) (E) BAR JOIST 4" CANT STRIP 4 RIGID INSLUATION BY ROOFER SINGLE PLY MEMBRANE ROOFING PATCH Sr ROOFER C4X5.4 - BLOCKING TO BLOCK UP CURB. (TYP. 4 CORNERS) NOTE ALL ROOFING CHANGES 4 PENETRATIONS ARE TO BE DONE IN ACCORDANCE WITH APPROVED ROOFING MANUFACTURES ROOFING SYSTEM INSTALLED. THE CURB FURNISHED AND INSTALLED BY G.G. SHALL BEAR DIRECTLY ON STRUCTURAL STEEL, NOT METAL DECK MECHANICAL UNIT MUST SET LEVEL. C4X5.4 -6" BLOCKING TO BLOCK UP CURB. (TYP. 4 CORNERS) HVAC UNIT PER EACH LOCATION STL. ANGLE UNIT FRAME SECURE TO CURB WITH 3/16" LAG BOLTS 51 24" O.C. STEEL ANGLE SUPPORT L 4" X WELDED TO ROOF SECURE ROOF CURB STEEL ANGLE W/ 3/8" THRU -BOLTS 24' O.C. L 2" X 2" X 1/4" JOIST STRUT EA. LOAD POINT MECHANICAL CURB L2 "X2 "X1 /4" JOIST STRUT 41 EA. LOAD POINT 3/16 3/16 3/16 / 3/16 3/16 3/16 3/16 I>_< 3/16 3/16 STEEL ANGLE FRAME CURB SUPPORT L 4" X 4" X 1/4" WELDED TO ROOF FRAMING. SECTION AT HVAC UNIT SCALE: 1 1/2' =T -0' ><1 3/16 3/16 SECTION e HVAC UNIT SCALE: 11/2' =1' -0' L2 "X2 "X1 /4" - JOIST STRUT 6 EA. LOAD POINT MECHANICAL CURB C4X5.4 -6" BLOCKING TO BLOCK UP CURB. (TYP. 4 CORNERS) L 4" X 4" X X 1/4" X 6" JOIST CLIPS (TYP.) (E) BAR JOIST L 2" X 2" X 1/4" JOIST STRUT 6 EA. LOAD POINT 3/16 3/16 (E) ROOF DECK TOP OF CURB TO BE LEVEL AT ALL FOUR CORNERS VERIFY ROOF SLOPE IN THE FIELD 3/16 3/16 > < MING. TO / 3/8 24' O.C. 0 • 1 s 0 1 i II .1 1, ,,1 1 1 1 9, I ii g ., 1 , 4 , ., 423Mr=0KM="AMM=MERG=71:4 EX 28" BAR JOIST EX 28" BAR JOIST EX 28" BAR JOIST LOCATION FOR NEW TENANT HVAC UNIT EQUIPMENT WEIGHT 5 TON UNIT / (825 LB5) I EX 28" BAR JOIST EX 28" BAR JOIST EX 28" BAR JOIST EX 28" BAR JOIST cc) m ROOF PLAN SCALE: 118' =1' -0' SCALE: 1/2' =1' —O' 3/16 3/16 • EX 28" BAR JOIST EX 28" BAR JOIST EX 28" BAR JOIST EX 28" BAR JOIST EX 28" BAR JOIST EX 28" BAR JOIST IA A6.1 LOCATION FOR. NE TENANT HVAG UNIT EQUIPMENT WEIGHT - 1.5 TON UNIT / (1428 LBS) I EX 28" BAR JOIST L 4" X 4" X X 1/4" X 6" JOIST CLIPS (TYP.) PART ROOF PLAN HVAC UNIT 6' -62" L4 "X4 "XX1 /4" X JOIST CLIPS (TYP.) PART ROOF PLAN HVAC UNIT SCALE: 1/2' =1' —O' PLAN ORTH 6 EX 14" BAR JOIST \ I EX 14" BAR JOIST Ex 14" BAR JOIST - EX 14" BAR JOIST EX 14" BAR JOIST 2' -2" 3/I6 3/16 3/16 3/16 TO FACE OF SUPPORT • 'XI/ -" "x 114" i I L 4" X 4" X X 1/4" X 6" JOIST CLIPS (TYP.) JOIST iiOh��ll ■_._._■ ■ ■■ ( 2 : JO 5 Ank Nor 3/16 3/16 3/16 Ark 3/16 O 3/16 3/16 2' -2" TO FACE OF SUPPORT L4 "X4 "XX1 /4" X6" JOIST CLIPS (TYP.) 3/16 bO 2 \\* : I I I" 3/16 V O -IN !L I O Lu l_ O REVIEWED FOR CODE COMPLIANCE APPROVED JAN 0 6 2010 City of Tukwila BUILDING DIUlclnn,' RECEIVED CITY OF TUKWILA DEC 2 2 2009 PERMIT CENTER DATE: II/15/09 JOB NO: 09 -066 DRAWN: STAFF CHECKED: KB 3405 KENNETH L. BUTTS ARCHITECT AIA 124 STAGECOACH ROAD BELL CANYON, CA 91307 (818) 999 -4272 KENNETH L. BUTTS STATE OF WASHINGTON (ADDTzt D• E • S• I • G• N 225 OAKLAND RAOD, SUITE 105 TEL: (860)183 - 5610 SOUTH WINDSOR, CT 06014 FAX: (860) 183 DEC 0 8 2009 • REGISTERED I�RCHITECT W 0 - CC cc L W L OZ r coL oCU WI< t H —�r NOQz O � = J E O 0 O N E co rl — CO STORE NUMBER %TBD REVISIONS 'A'- ISSUE: LANDLORD COMMENTS DATE: 12/1/09 'B' -ISSUE DATE 'C'- ISSUE DATE 'D'- ISSUE DATE SHEET TITLE ROOF PLAN/ HVAC UNIT INSTALLATION SCALE AS NOTED SHEET NUMBER A6.1 (R�'U - CHEDULE (FIXTURE INDICATED WITH CLOUD BELOW ARE BY LANDLORD - ACCENT LTG. BY TENANT) 5YM MARK DESCRIPTION MFG CATALOG# LAMP TYPE VOLTAGE MOUNTING REMARKS A • TPUT T -5 2 T FLUORESCENT FIXTURE (2) LAMP HIGH METALUX 2AC- 254WT5 -UNV 3500K (2) 54 -5 UNIV RECESSED SUPPLIED /INSTALLED BY L.L. 0 A►/EM -• 4 FLUORESCENT FIXTURE (2) LAMP HIGH • ■ TPUT T -5, WI' EMERGENCY BALLAST AND q 0 MINUTE BATTERY BACK-UP METALUX 2AG- 254WT5 -UNV (2) 54WT -5 3500K UNIV RECESSED SUPPLIED /INSTALLED BY L.L. w '_ Al 2 . FLUORESCENT FIXTURE W PRISMATIC. DIFFUSER METALUX 2688- FA232A- UNIV -EB5I (2) 321 -T8 UNIV RECESSED SUPPLIED /INSTALLED BY L.L. 0 1 _ Al /EM 4 FLUORESCENT FIXURE WITH PRISMATIC • IFFUSER WITH EMERGENCY BALLAST AND q0 MIN. BATTERY METALUX 2688- FA232A- UNIV- EM -EBBI (2) 321^1-T8 UNIV RECESSED SUPPLIED /INSTALLED BY L.L. pr _ I B SEMI RECESSED WALL WASH -- rl1RE CON-TECH RA54 -0MHE 10W/E8 -I UNIV RECESSED TENANT SUPPLIED /INSTALLED BY G.G. (M B1/)I TRACK MOUNTED METAL HALIDE WALL ! ' 4 A 4 IER, MOUNTED IN SINGLE CIRCUIT TRACK, COLOR WHITE CON-TECH GTL7017WW- P- LF- 1 UV 00- TOWED-IT UNIV ANT TENANT SUPPLIED /INSTALLED BY G.G. a B 1 b b B 3 a a B 1 1 b F ) LAMP FLUORESCENT STRIP METALUX 5NF -132- UNV -EB81 (I) 321T ' RUBBER COATED SHATTER PROOF LAMPS UNIV SUSPENDED SUPPLIED/INSTALLED BY L.L. X EDGE - LIT EXIT 516N NAVILITE NXESB INCLUDED UNIV UNIVERSAL SUPPLIED /INSTALLED BY L.L. q0 MIN BATTERY BACK -UP NDARD LED EXIT SIGN q0 MIN BATTERY BACK -UP r ASTRALITE TP- U- R -1 -EM INCLUDED UNIV UNIVERSAL SUPPLIED / INSTALLED BY L.L. ��■ B 1—I \-.._.....-N Y UBLE HEAD EMERGENCY WITH q0 MIN BATTERY BACK - UP HIGHLITES HL-c10-DL INGULDED UNIV SUSPENDED SUPPLIED /INSTALLED BY Li. SEE PLAN FOR LOCATION 8 AUDIO SPEAKERS RECESSED TENANT SUPPLIED /INSTALLED BY G.G. 0 O ` �� f • e —1 f — —1 f— —1 f 9 I■ WITCH BANK -SEE ( f SWITCHING D:T'AIL 1 i 0 : ABOVE 11 Al /EM p... . A /EM A A A /EM A A A /EM 1 1114, \ 0 .. .. 15 15 / 15 a 1 b 3 15 b 3 a 1 15 a 1 - ' - — II - ■ / B ` 15 I i a IS f 9 ' P "A "1,3 -15 • 4N EL "A " 1. A .._ - A A A A A A A A' 13,15 I '' �.. e. _ - - 13 \ a 1 b 3 a 1 b 3 a 1 b 3 a 1 b 3 "A" 9 : 7 , , 1 "A " 5 - 7 - 15 liri F A A A A A A II A A' _ - - _ - - - _ - - - I I I - - _ "A "S i� _ A _....I.1 ,_....I.1 UMW" U. IRES IN 13 13 5 d 7 � - d 7 c 5 d 7 c 5 4 h 6 UIT AS I : IF LOCAL " WITH Y- B c 5 I :::: I Ilir 13 f 9 I F F A /EM A A A /EM A A A /EM A A I U :. - Rk " 4, . . . . _ - _ - - _ _ .�� i, ...., .... ■ ' J ' �_ :..: .... .... 13 13 15 c 5 d 7 15 d 7 c 5 15 I 6 g 4 : - SECURITY DOME I ;; (TYPICAL FOR 4) - U.. . ... I / V I . ... .... 3 / 15 13 a 1 — ■— I : ::: 'NIP" ■ ..■ I ... B - B B B B B B B B :::: P AI I Al ■..■ /AI W FAO F F f 9 e 11 f 9 e 11 f 9 e f 9 h 6 4 U..'. 11 A A A A A A A A I A g ... _ _ _ ■ - .. - - W. _= U U .. . 1 ... - - 11111111 - ■..■ ■..■ ■..■ 13 13 DAYUGHTING REQUIREMENT -4 NOTE: SEC ARCHITECTURAL RCP FOR LI6HT FIXTURE QUANTITIES NEW P (BY LL CONNECT EMERGENCY FIXT REAR AREAS TO SAME CIRC GENERAL LIGHTING AHEAD C SWITCHING IN ACCORDANCE N.E.C. AS REQURED FLOOR PLAN - LIGHTING WORK SCALE. va• - ra• +46 AFF O 0 0 • 0 2 -GANG LIGHT SWITCH - COVERPLATE O 0 0 0 0 0 0 ALES LIG I 0 SALE LIGHTIN G 0 I UGHTING SALES PROVIDE PERMANENT, TYPED LABELS AS SHOWN. 0 I SALES LIGHTING SWITCHING DETAIL NOT TO SCALE 6 -GANG LIGHT SWITCH COVER PLATE pe 0 ACCENT UGHTING 0 ACCENT UGHTING O 1 I LANDLORD WORK UNDER LANDLORD PERMIT CLARIFICATION OF LOCATION RUN EXTRA WIRE FOR GROUND (BY LL) (TYPICAL) SWITCH CONCEALED FROM VIEW (BY LL) J -BOX L FOR SIGN (BY DAYLIGHTING REQUIREMENT CURRENT UMITING DEVICE TO ALLOW MAXIMUM OF 300 W = = = = bo9 )4,1 O RECEIVED CITY OF TUKWILA DEC 2 2 2009 PERMIT CENTER DATE: 11/x/09 JOB NO: m9 - 066 DRAWN: STAFF CHECKED: DP a PO' Q -0 C u m tu STORE NUI�ER #TBD REVISIONS 'A' - ISSUE / \ LANDLORD WORK UNDER LANDLORD PERMIT DATE 12/6/09 'B'- ISSUE DATE 'G' - ISSUE DATE SHEET TITLE FLOOR PLAN LIGHTING WORK SCALE 1/4'=1 - 0' SHEET NUMBER E1.0 - 4 - o II o Al ■ • 1 ■I I I■ 1 1 _ _ - - + + I'I _ _ I O I I O • a B 1 b b B 3 a a B 1 1 b b B 3 a B 1 b b B 3 a a B B NOTE: SEC ARCHITECTURAL RCP FOR LI6HT FIXTURE QUANTITIES NEW P (BY LL CONNECT EMERGENCY FIXT REAR AREAS TO SAME CIRC GENERAL LIGHTING AHEAD C SWITCHING IN ACCORDANCE N.E.C. AS REQURED FLOOR PLAN - LIGHTING WORK SCALE. va• - ra• +46 AFF O 0 0 • 0 2 -GANG LIGHT SWITCH - COVERPLATE O 0 0 0 0 0 0 ALES LIG I 0 SALE LIGHTIN G 0 I UGHTING SALES PROVIDE PERMANENT, TYPED LABELS AS SHOWN. 0 I SALES LIGHTING SWITCHING DETAIL NOT TO SCALE 6 -GANG LIGHT SWITCH COVER PLATE pe 0 ACCENT UGHTING 0 ACCENT UGHTING O 1 I LANDLORD WORK UNDER LANDLORD PERMIT CLARIFICATION OF LOCATION RUN EXTRA WIRE FOR GROUND (BY LL) (TYPICAL) SWITCH CONCEALED FROM VIEW (BY LL) J -BOX L FOR SIGN (BY DAYLIGHTING REQUIREMENT CURRENT UMITING DEVICE TO ALLOW MAXIMUM OF 300 W = = = = bo9 )4,1 O RECEIVED CITY OF TUKWILA DEC 2 2 2009 PERMIT CENTER DATE: 11/x/09 JOB NO: m9 - 066 DRAWN: STAFF CHECKED: DP a PO' Q -0 C u m tu STORE NUI�ER #TBD REVISIONS 'A' - ISSUE / \ LANDLORD WORK UNDER LANDLORD PERMIT DATE 12/6/09 'B'- ISSUE DATE 'G' - ISSUE DATE SHEET TITLE FLOOR PLAN LIGHTING WORK SCALE 1/4'=1 - 0' SHEET NUMBER E1.0 KEY NOTES (LANDLORD WORK) 0 PROVIDE (4) 3/4" CONDUITS, (1) DEDICATED P.O.S. CIRCUIT, (1) FOR GENERAL POWER CIRCUIT, (1) CAT 5 CABLE AND PHONE UNE. (1) SPARE. ROUTE CONDUITES AS SHOWN ON PLAN DOWN WALL OR COLUMN, STUB CONDUIT INTO FLOOR MOUNTED JUNCTION BOX. ROUTE FLEXIBLE CONDUIT THROUGH CABINET BASE TO EACH RECEPTACLE. COORDINATE EXACT CONFIGURATION WITH TENANT REP. AND EXACT LOCATION WITH FIXTURE INSTALLER. (ALL LOW VOLTAGE WIRING SHALL BE INSTALLED BY TENANT VENDER AS CONTRACTED BY G.C.) 0 PROVIDE 3/4" CONDUIT WITH PULLWIRE FROM CASH /WRAP TO TELEPHONE BACKBOARD IN STOCKROOM. 0 QUAD RECEPTACLE AND J —BOX FLUSH MOUNTED IN WALL AT 72" AFF. ROUTE 1" EMPTY CONDUIT WITH PULLWIRE FROM J —BOX TO 6" ABOVE CEILING FOR SPEAKER CABLES. SPEAKER CABLES ABOVE CEILING SHALL BE IN CONDUIT OR SHALL BE PLENUM RATED. VERIFY SOUND SYSTEM EQUIPMENT AND REQUIREMENTS WITH SYSTEM SUPPUER. ® PROVIDE A QUAD RECEPTACLE, GENERAL QUAD RECEPTACLE, FOR GENERAL PURPOSE POWER AT THE RECEMNG DESK, LOCATED AT 3' -2" A.F.F. ® DUPLEX IG RECEPTACLE FLUSH MOUNTED VERTICAL AT 10' -0" AFF FOR SECURITY SYSTEM. 10 SUPPLY AND INSTALL THE FOLLOWING SERVICE BELL SYSTEM. a ) EDWARDS #88) EDWARDS #852 85 PUSSHASFONMMOUNTED AT 48" AVE AT REAR DOOR c) EDWARDS #340 -4G5 BELL MOUNTED ABOVE COORIDOR CEILING d) EDWARDS #340 -405 BELL MOUNTED ABOVE CASH/WRAP CEIUNG 0 FIELD VERIFY EXACT LOCATION OF LANDLORD TELEPHONE SERVICE STUB —IN AND EXTEND AS REQUIRED FOR CONNECTION TO TENANT TELEPHONE EQUIPMENT. PROVIDE 3/4" PLYWOOD BACKBOARD FOR MOUNTING OF NEW ELECTRICAL AND TELEPHONE EQUIPMENT, SIZE AND SECURE AS REQUIRED. PROVIED ISOLATED GROUND DUPLEX RECEPTACLE FOR POWER TO TELEPHONE EQUIPMENT. BY LANDLORD. 1© PROVIDE A QUAD IG RECEPTACLE FOR COMPUTER SYSTEM, LOCATED AT 3' -2" A.F.F. 14 RJ31x JACK FOR CHECKPOINT /SECURITY SYSTEM. KEY NOTES (TENANT WORK) 0 THE CIRCUITES USED TO POWER THE CASH REGISTERS /COMPUTERS SHALL NOT BE USED FOR ANY OTHER PURPOSE. CIRCUITS SHALL NOT SHARE NEUTRAL OR GROUND WITH OTHER EQUIPMENT. SEPARATE POWER, NEUTRAL AND ISULATED GROUND WIRES MINIMUM SIZE #12 AWG SHALL BE RUN TO THE CIRCUIT BREAKER PANEL BOARD WHERE GROUND WIRE SHALL BE TIED TO THE GROUND TERMINAL ISOLATED FROM NEUTRAL DO NOT USE CONDUIT FOR GROUNDING AS THIS MAY NOT BE CONTINUOUS. CASH REGISTER CIRCUIT SHALL BE RUN IN SEPARATE CONDUIT. RECEPTACLES SHALL BE HUBBEL #IG -5362 ORANGE. ® DEVICES SURFACE MOUNTED ON CABINET INTERIOR AT 12" AFF. FIELD VERITY LOCATION OF CABINET SHELVING PRIOR TO INSTALLATION. LANDLORD WORK UNDER LANDLORD PERMIT RUN 2 CAT 5 NETWORK CABLES FROM RJ45 JACKS AT CASHWRAP TO RJ45 JACKS AT RECEMNG TABLE IN STOCKROOM. PROVIDE 18" CABLES AT EACH LOCATION FOR CONNECTION OF CASH/WRAP HUB AND RECEIVING COMPUTER. CABLES TO BE PLENUM RATED IF NOT INSTALLED IN CONDUIT. MOUNTED AT 3' -2" A.F.F. (ALL LOW VOLTAGE WIRING SHALL BE INSTALLED BY TENANT VENDER AS CONTRACTED BY G.C.) TGC TO RUN AN EXTRA CABLE THROUGH THE CEILING AND LEAVE IT COILED FOR FUTURE USE. ALARM SYSTEM WIRING TO BE BY VENDOR. JUNCTION BOX FOR SHOPPERTRAK ORBIT. COORDINATE EXACT LOCATION IN FIELD WITH SHOPPERTRAK REPRESENTATIVE. PROVIDE (1) CAT 5 PLENUM RATED CABLE IN 3/4" CONDUIT FROM ORBIT LOCATION AT FRONT DOOR TO CONTROLLER LOCATION AT MAIN TEL /DATA BACKBOARD. CABLE IS BELDEN #1701A. LEAVE SUFFICIENT SLACK AT EACH J —BOX FOR CONNECTION (15' -0" MIN. PER MANUFACTURER'S RECOMMENDATIONS) (ALL LOW VOLTAGE WIRING SHALL BE INSTALLED BY TENANT VENDER AS CONTRACTED BY G.C.) ZONE ADDRESSABLE MODULE (TYPICAL) SPRINKLER TAMPER SWITCH EOLR. SPRINKLER — FLOW SWITCH S S S V V V • V • V • • • • NI • • • STROBE ONLY (TYPICAL FOR 3) NEW HORN /STROBE MOUNTED 80" TO BOTTOM OF DEVICE OR 6" FROM CEIUNG — WHICHEVER IS GREATER (TYPICAL FOR 6) NEW PULL STATION (TYPICAL FOR 3) m (MOUNTED 48" MAX A.F.F. TO CENTERUNE OF DEVICE) EOLR 18 TSP (TYPIC it SIGNAUNG DEVICES AWG CU FIRE ALARM INTERFACE FOR CONNECTION TO LANDLORD'S CENTRAL FIRE ALARM SYSTEM FIRE ALARM SCHEMATIC NOT TO SCALE EOLR L NEW CEIUNG MOUNTED SMOKE DETECTOR (TYPICAL FOR 6) EOLR DUCT MOUNTED SMOKE DETECTOR (TYPICAL FOR 2) INITIATING DEVICES EXTEND AND CONNECT TO LANDLORD MAIN ARE ALARM SYSTEM AS REQUIRED. C COORDINATE WITH LANDLORD ALL CONNECTIONS TO LANDLORD'S SYSTEM. (BY LL) DEDICATED DUPLEX RECEPTACLE HUBBELL#IG -5362 ORANGE FOR CASH REGISTER COMPUTER AT 12" AFF EXTRA WIRE ;4‘VflUN FOR GROUND (TYPICAL) 3/4 TO TTB "C. IN FLOOR 10 "A " 26,28 '. "A" 22 �L %/' ©© STUB —U (TYPICAL) ENERAL USE QUADPLEX HUBBELL #5362 —WHI AT 12" AFF FLEXIBLE CONDUIT IN CABINET BASE CASH DESK WIRING DETAIL SCALE' 1/4• - 1-0• PUSH BUTTON RECEPTACLE FOR REFRIGERATOR (15" A.F.F.) NEW PANEL "A" —ew (BY LL) RECEPTACLE FOR MICROWAVE (36" A. F.F.) UNIT HEATER SUSPENDED FROM ABOVE FLOW AND TAMPER SWITCH SHALL BE — INSTALLED AS PART OF FIRE ALARM SYSTEM BY LANDLORD— VERIFY EXACT LOCATION AND MOUNTING REQUIREMENTS IN FIELD. — 1'A"12,18 "A "14,16 / / TO' BUZZER AN 37,39,41 3— #12- 1/2"C. NEW WATER HEATER ABOVE MOP SINK SEE SHEET E4 FOR SCHEMATIC LAYOUT OF LOW VOLTAGE INTERFACES DETAIL FURNISH AND INSTALL NEW STOBE ONLY (TYPICAL —BY LL) K38,40,4 FURNISH AND INSTALL NEW CEILING MOUNTED SMOKE DETECTOR (TYPICAL —BY LL) — #8 -1 /2"C. NEW DISCONNECT - WITCH #2 ON ROOF (BY 1) (60/45, NEMA 3R) NEW A.. UNIT #2 ON ROOF I 'Or 75 FIRE ALARM IN RFACE (BY LL) J 75 s SPEAKER (TYPICAL) SEE CASH DESK DETAIL THIS SHEET FOR WIRING INFORMATION IN THIS AREA SPEAKER WIRE (TYPICAL) "A "32,34,3 3—#8-1/2"C. FLOOR PLAN - MISCELLANEOUS ELECTRIC WORK SCALE. 1/4• - 1-0° FURNISH AND INSTALL NEW PULL STATION (TYPICAL —BY LL) FURNISH AND INSTALL NEW ACCESSABLE SMOKE DETECTOR IN RETURN DUCT. PROVIDE AND INSTALL WIRING TO FAN INTERLOCK. (TYPICAL —BY LL; CAT 5 CABUNG WITH WHIP TO JB AT T.T.B:■•■, IT —NEW A.C. UNIT #1 ON ROOF 15' -10" —ALL DEVICES SHALL BE A MINIMUM 75 CANDELLA AND SHALL COMPLY WITH NFPA 72 AND ALL OTHER STATE AND LOCAL REQUIREMENTS. `A "10 RECEPTACLE MOUNTED --1 (TYPICAL SHOW WINDOW (TYPICAL FOR 2 —BY LL) O f J LANDLORD WORK UNDER LANDLORD PERMIT 01-- bl RECEIVED CITY OF TUKWILA DEC 2 2 2009 PERMIT CENTER DATE: I1/IB /09 JOB NO: 09 - 066 DRAWN: STAFF CHECKED: DP I ' Pg dig Q Wa- cc cc a �z Woo cc 0°) U• � t a d �rF —Cn L L CO V SHEET TITLE H - 0 - 0 C to m .0 l0 .0 SCALE 1/4' -1' - O' SHEET NUMBER E2.0 STORE NUMBER REVISIONS #TBD 'A' -ISSUE A LANDLORD WORK UNDER LANDLORD PERMIT PATE 12/6/09 'B' -ISSUE DATE 'C' -I88UE DATE FLOOR PLAN MISCELLANEOUS ELECTRIC WORK PANEL NEW PANEL "A" BY LL LUGS MAIN 225 AMP 120/208 VOLT 3 PHASE 4 WIRE BREAKER 200 AMP USE CKT. NO. LOAD BKR SIZE A B C BKR SIZE LOAD CKT. NO. USE SALES AREA LIGHTS 1 1188 20 20/i 1200 2 SIGN i III 01 A �-� III =1111 IN II III oi ill di a � N 3 972 394 4 STORE FRONT LIGHTS 5 1080 394 6 i 7 864 280 8 TRACK LIGHTING ACCENT LIGHTS 9 700 360 10 SHOW WINDOW RECPT. 11 630 1200 12 MICROWAVE REAR AREA LIGHTS 13 714 180 14 SECURITY SYSTEM =IIII -1111 _01 EM /NIGHT LIGHTS 15 727 500 16 TTB RECPT. 011 01 ok 1 a i �-� ^� i i ��� a i ^ ^ T.E. FANS 17 180 /3 660 18 REFRIGERATOR REC. DESK IG 19 360 - 20 SPARE REC. DESK RECPT. 21 360 1440 22 CASH DESK RECPT. HOT WATER HEATER 23 1500 360 24 HVAC RECPT. MANAGERS DESK IG 25 500 1 000 26 CASH REGISTER MANAGERS DESK RECPT 27 360 1000 28 i � A SOUND SYSTEM 29 500 - 30 SPARE SHOPPER TRACK SYSTEM 31 1000 4 5 /3 5200 32 GENERAL RECPT. 33 1440 5200 34 A.C. UNIT #1 TOILET ROOM RECPT. 35 360 20 5200 36 37 1666 3 /3 3543 38 UNIT HEATER 39 1666 3543 40 A.C. UNIT # 41 1666 , I 3543 42 TC1 TC1 TC1 TC1 TC2 TC2 * * " *" INDICATES PANEL LOCKS "TC #" INDICATES TIME CLOCK 2" RIGID INSULATION PANEL DIRECTORY PHASE A: 17695 WATTS PHASE B: 18662 WATTS PHASE C: 17273 WATTS TOTAL: 53630 WATTS GROUND PER NEC CONCRETE ENCASED ELECTRODE SPECIAL NOTE: IG AND GA RECEPTACLES SHALL BE RATED AT 20 AMPERES AND SHALL HAVE A DEDICATED INSLUATED GREEN GROUND WIRE, THE GROUND WIRE SHALL BE RUN CONTINUOUS AND UNSPLICED BETWEEN THE DEVICE AND THE PANEL GROUND BUS FILL VOID WITH FIBERGLASS INSULATION 1" CONDUIT ROOF DECK — (VERIFY EXACT CONSTRUCTION AND PENETRATE AS REQUIRED) BUILDING WATER (2) -3/4 "X10' STEEL SERVICE GROUND RODS PIPING BALANCE: 7.44 % GALVANIZED SHEET METAL HOOD SHEET METAL OR FLEX —TUBE COLLAR WOOD NAILER— PROVIDE FASTNERS 24" O.C. MAX. 26 GA. COUNTERFLASHING CONDUIT THRU ROOF DETAIL NOT TO SCALE TC3 TC2 TC2 TC3 GROUNDING SHALL CONSIST OF COPPER CONDUCTORS IN CONDUIT WITH BOLTED, OR BRAZED, CONNECTION TO EACH ILLUSTRATION BELOW FOR THE NEUTRAL GROUNDING AND BONDING SHALL COMPLY WITH NEC ARTICLES 230 & 250. ALL METALLIC RACEWAYS SHALL BE GROUNDED SUGGESTED SERVICE GROUND DETAIL NOT TO SCALE 12' MIN. ROOF FELTS AND FLASHING PAWL "A" FEEDER LCL signage, general lighting, cash register, unit heater, etc_ s ham-window or entry. lighting (at shauwwindaw) track lighting xtrack lighting(showirroindauu) xx a.c. equipment(rtu. ahu, cu. etc.)- •80 volt "x ac. equipment(rtu, ahu, GU. etc.) -203 volt Sub Total NON LCL water heater. sensormatic, traffic counter, misc.. etc, xxx receptacles x"`ss how windaru lighting requirement in feeder only) Sub Total TOTAL INPUT 10333 2+30 iR a 723 12258 27 FACTOR 1.25 1.25 75 75.00 831,3$ 300.28 1 1 VA 13575 350 0 1200 0 26227 41355 12253 r 21218 62573 4a7 to - total amperage egauls r� 208 wit • total amperage egauis 75.3 173.7 GRADE " Track calculated per 2005 NEC Article 220.43(3) "x MCA used includes 125% of largest motor per 2005 NEC Article 223.13(A) xnx . c: alculated P er2005NEC A.rk rcIe220tW istl0kta 100%, Allather 506 "" $hauwwindo>tu lighting calculated er 99 NEC Article 220:. 43 ....................2001lA per LF afshaouundow minus actual lighting installed NEW METER FOR SPACE BY LL r, EX. METER SOCKET FOR SPACE PROVIDED BY LL EX. 200 AMP DISCONNECT FOR SPACE PROVIDED BY LL RISER DIAGRAM NOTES 1. CONTRACTOR SHALL OBTAIN AVAILABLE FAULT CURRENT RATING AND PROVIDE PROTECTION FOR MAIN CIRCUIT BREAKER AND ALL BRANCH DEVICES AS REQUIRED. 2. CONTRACTOR TO MAINTAIN ALL REQUIRED CLEARENCES PER ARTICLE 110 -26 NEC APPROX. 125' -0" TIMECLOCK #1 FOR AUTOMATIC LIGHTING CONTROL /SHUTOFF IN ACCORDANCE WITH THE 2006 WASHINTON STATE ENERGY CODE TIMECLOCK #1 FOR AUTOMATIC LIGHTING CONTROL /SHUTOFF IN ACCORDANCE WITH THE 2006 WASHINTON STATE ENERGY CODE TYPE r .. \ 'G GFI WP V V I T.T.B. SERVICE TO SPACE TO BE 120/208 VOLT, 3PH, 4W., 200 AMP BY LANDLORD (4— #3/0 -2" C. MIN. —SEE NOTE 3 BELOW) SYMBOLS AND ABBREVIATIONS RECESSED INCANDESCENT FIXTURE SINGLE POLE SWITCH DUPLEX WALL RECEPTACLE QUADRAPLEX ISOLATED GROUND RECEPTACLE GROUND FAULT QUADRAPLEX WALL RECEPTACLE QUADRAPLEX WALL RECEPTACLE WEATHERPROOF RECEPTACLE JUNCTION BOX TELEPHONE TELEPHONE /DATA OUTLET DATA OUTLET TELEPHONE CONDUIT TELEPHONE TERMINAL BOARD O 8 3— #8- 1/2"C. MIN. (BY LL) OUTLET ELECTRIC RISER DIAGRAM NOT TO SCALE 10- 3— #8- 1/2"C. MIN. (BY LL) NEW PANEL "A" 3. AT TIME OF DESIGN 1 3/4" CONDUIT PRESENTLY EXISTS TO SPACE. SERVICE SIZE, WIRE SIZE, TYPE, AND INSTALLATION IS UNKNOWN. CONTRACTOR TO VERIFY EXISTING SERVICE AND INSTALLATION TO SPACE IS ADEQUATE WITH THE NEW DESIGN MINIMUM SERVICE SIZE, WIRE SIZES, ETC SHOWN ABOVE IN THE DIAGRAM. IF ANY PORTION OF EXISTING INSTALLATION IS INADEQUATE PER THE NEW DESIGN, CONTRACTOR SHALL INSTALL TO ACCOMODATE THE DESIGN. (BY LL) NEW TIME CLOCK (TYPICAL FOR 3) 0 S S S lI S HOME RUN CONDUIT EX EXISTING TO REMAIN EXR EXISTING RELOCATED SHTR SHOPPERTRACK D DATA T TELEPHONE F FAX M MODEM OCCUPANCY SWITCH LL LANDLORD INSTALLED oC FIRE ALARM SYMBOLS AND ABBREVIATIONS SMOKE DETECTOR (SIMPLEX #4098 -9714) DUCT SMOKE DETECTOR (SIMPLEX #4098 -9756) PULL STATION (SIMPLEX #4099 -9001) 75 EXACT REQUIREMENT A F FOR DEVICES WITH SSIMPLEXX, —9351 — COORDINATE S INDICATES CANDELLA RATING OF DEVICE 0 SPEAKER STROBE (EQUAL TO SIMPLEX SERIES 4903 -9451 — COORDINATE 7 ; EXA REQUIREMENT FOR DEVICES WITH SIMP `L INDICATES CANDELLA RATING OF DEVICE 1 4—NEW DISCONNECT SWITCH #1 ON ROOF BY LL (60/50, NEMA 3R MIN.) NEW A.C. UNIT #1 ON ROOF (BY LL) NEW DISCONNECT SWITCH #2 ON ROOF BY LL (60/45, NEMA 3R MIN.) NEW A.C. UNIT #2 ON ROOF (BY LL) A LANDLORD WORK UNDER LANDLORD PERMIT CLARIFICATION FOR MAIN LUG ONLY PUSHBUTTON [�B BUZZER Q TRANSFORMER MCA MINIMUM CIRCUIT AMP MOCP MAXIMUM OVERCURRENT PROTECTION CONDUIT ABOVE FLOOR CONDUIT BELOW FLOOR MARKS INDICATE NUMBER OF WIRES TIMECLOCK #1 FOR AUTOMATIC LIGHTING CONTROL /SHUTOFF IN ACCORDANCE WITH THE 2006 WASHINTON STATE ENERGY CODE toc ,2&,t7 0 4,0 q,p_ 4/0 4 $4 RECEIVED CITY OF TUKINILA DEC 22 lung PERMIT CENTER DATE: 11119/09 JOB NO: 09 - 066 DRAWN: 8TAFF CHECKED: DP -ISSUE DATE 'C' -ISSUE DATE Q -0 REVISIONS 'A' -ISSUE A LANDLORD WORK UNDER LANDLORD PERMIT DATE 12/6/09 SHEET TITLE ELECTRICAL DETAILS SCALE 1/4' @1' - 0' SHEET NUMBER E3.0 CKUP UNIT REGIS1ER 1 UNE 2 HUB CASHWRAP REGiS1ER 2 8" RADIUS PROVIDE COVER PLATES COLOR SELECTED BY ARCHITECT REGISTER 3 CASH .GP PQS LIE1 CIRCUIT LINE 2 LDMARK PRINTER 1ELEPHONE UNE 1 SCHEMATIC LAYOUT OF LOW VOLTAGE INTERFACES NOT TO SCALE BUSHING WITH PULL STRING STUBBED TO ACCESSIBLE LOCATION ABOVE CEIUNG (1) 1" CONDUIT TO ACCESSIBLE SPACE IN CEILING (2) GANG DEEP BACK BOX WITH SINGLE GANG EXTENSION BOX 18" AFF— VERIFY WITH ARCHITECT SCANNER BACK OFFICE PC PRINTER MANAGER'S OFFICE RECEIVING DESK FAX CEILING FLOOR NOTE: TYPICAL WHEN ANY OF THE FOLLOWING SYMBOLS Y , V AND SZ ARE SHOWN ON PLAN. PROVIDE AS SHOWN ABOVE TELEPHONE /DATA RISER DETAIL NOT TO SCALE MODEM MANAGER'S DESK TELCO DEMARK 581( OR T)SL FRAME RJ-31X FOR ALARM FROM TTB: RECEIVING DESK HAS 4 BOXES. (1) RJ45 FOR UNK TO CASH WRAP, (1) FOR UNE 1, (1) FOR UNE 2, FOR 56 K CIRCUIT UNE 1 GOES TO THE MANAGER'S OFFlCE, THE RECEIVING DESK AND THE CASH WRAP VIA THE RECEIVING DESK. UNE 2 GOES TO THE CASH WRAP AND THE RECEIVING DESK UNE 3 GOES TO THE MANAGER'S OFFICE FAX MACHINE RECEIVING DESK DATA/TELEPHONE FACEPLATE REQUIREMENTS REGISTER 1 1 L2 # # ## ■rnr iL = - I r 5ii POS1 [i0 POS2 1 RECEIVING DESK SHOPPERTRAK [ POWER DATA 1 O l I REGISTER4 (®) D MANAGER'S OFFICE l I Li #### L3-FAX Mrn I (c) 1 4 p4K% Q4, RECEIVED CITY OF TUKWILA ni:C 2 2 7009 PERMIT CENTER DATE: I1/5/09 JOB NO: 09 66 DRAWN: STAFF CHECKED: DP a 1 Q -0 W �- a W ao �Z� W� w � � � Z � T (N 0 <C2 LO N V,T11-V, 'S' -ISSUE DATE 'C' -ISSUE PATE L co V 41) 0 0 co :a U) a, co MORE NUMBER #TBD REVISIONS 'Ai LANDLORD WORK UNDER LANDLORD PERMIT PATE 12/6/09 SHEET TITLE LOW VOLTAGE DIAGRAMS SCALE 1/4 " -1' — O' SHEET NUMBER E4.0 [ 1 I L1 #### L2 #### I CIRCUIT I I.::!.-:I, I POS 1 POS 2 - I 1 () I CKUP UNIT REGIS1ER 1 UNE 2 HUB CASHWRAP REGiS1ER 2 8" RADIUS PROVIDE COVER PLATES COLOR SELECTED BY ARCHITECT REGISTER 3 CASH .GP PQS LIE1 CIRCUIT LINE 2 LDMARK PRINTER 1ELEPHONE UNE 1 SCHEMATIC LAYOUT OF LOW VOLTAGE INTERFACES NOT TO SCALE BUSHING WITH PULL STRING STUBBED TO ACCESSIBLE LOCATION ABOVE CEIUNG (1) 1" CONDUIT TO ACCESSIBLE SPACE IN CEILING (2) GANG DEEP BACK BOX WITH SINGLE GANG EXTENSION BOX 18" AFF— VERIFY WITH ARCHITECT SCANNER BACK OFFICE PC PRINTER MANAGER'S OFFICE RECEIVING DESK FAX CEILING FLOOR NOTE: TYPICAL WHEN ANY OF THE FOLLOWING SYMBOLS Y , V AND SZ ARE SHOWN ON PLAN. PROVIDE AS SHOWN ABOVE TELEPHONE /DATA RISER DETAIL NOT TO SCALE MODEM MANAGER'S DESK TELCO DEMARK 581( OR T)SL FRAME RJ-31X FOR ALARM FROM TTB: RECEIVING DESK HAS 4 BOXES. (1) RJ45 FOR UNK TO CASH WRAP, (1) FOR UNE 1, (1) FOR UNE 2, FOR 56 K CIRCUIT UNE 1 GOES TO THE MANAGER'S OFFlCE, THE RECEIVING DESK AND THE CASH WRAP VIA THE RECEIVING DESK. UNE 2 GOES TO THE CASH WRAP AND THE RECEIVING DESK UNE 3 GOES TO THE MANAGER'S OFFICE FAX MACHINE RECEIVING DESK DATA/TELEPHONE FACEPLATE REQUIREMENTS REGISTER 1 1 L2 # # ## ■rnr iL = - I r 5ii POS1 [i0 POS2 1 RECEIVING DESK SHOPPERTRAK [ POWER DATA 1 O l I REGISTER4 (®) D MANAGER'S OFFICE l I Li #### L3-FAX Mrn I (c) 1 4 p4K% Q4, RECEIVED CITY OF TUKWILA ni:C 2 2 7009 PERMIT CENTER DATE: I1/5/09 JOB NO: 09 66 DRAWN: STAFF CHECKED: DP a 1 Q -0 W �- a W ao �Z� W� w � � � Z � T (N 0 <C2 LO N V,T11-V, 'S' -ISSUE DATE 'C' -ISSUE PATE L co V 41) 0 0 co :a U) a, co MORE NUMBER #TBD REVISIONS 'Ai LANDLORD WORK UNDER LANDLORD PERMIT PATE 12/6/09 SHEET TITLE LOW VOLTAGE DIAGRAMS SCALE 1/4 " -1' — O' SHEET NUMBER E4.0 ELECTRICAL EQUIPMENT AND MATERIAL UNIT HEATER: TRANE #UHEC- 052AACA, HORIZONTAL, 5 KW, 208 VOLT, 3 PH., 60 HZ, COMPLETE WITH HORIZONTAL WALL /CEILING SWIVEL MOUNTING BRACKET, 24 VOLT CONTROL TRANSFORMER AND ROOM THERMOSTAT. PANEL A: SQUARE D TYPE NQODCU SURFACE MOUNTED COPPER BUS, BOLTED CIRCUIT BREAKER PANELBOARD, 120/208 VOLT, 3 PH., 4 WIRE. A.C. UNIT DISCONNECT SWITCH: HEAVY DUTY SINGLE THROW SAFETY SWITCH, 3 POLE, 60 AMP, 240 VOLT, FUSIBLE, WITH FUSES AS SHOWN IN PLAN AND NEMA 3R ENCLOSURE. SQUARE D #H322. A.C. UNIT DISCONNECT SWITCH: HEAVY DUTY SINGLE THROW SAFETY SWITCH, 3 POLE, 60 AMP, 240 VOLT, FUSIBLE, WITH FUSES AS SHOWN IN PLAN AND NEMA 3R ENCLOSURE. SQUARE D #H322. TIME CLOCK #1: TORK #W -4001, 4PST, 40 AMP, 120 VOLT, WITH 7 DAY DIAL, WITH MANUAL OVERRIDE AND 24 HOUR RESERVE POWER FEATURE IN ACCORDANCE WITH THE 2001 IECC. TIME CLOCK #2: TORK #W -300L, 3PST, 40 AMP, 120 VOLT, WITH 7 DAY DIAL, WITH MANUAL OVERRIDE AND 24 HOUR RESERVE POWER FEATURE IN ACCORDANCE WITH THE 2001 IECC. TIME CLOCK #3: DPST, 40 AMP, 120 VOLT, WITH 7 DAY DIAL, WITH RESERVE POWER FEATURE. TORK #W220L. RECEPTACLES: HUBBELL #5362. GROUND FAULT RECEPTACLES: HUBBELL #GF_5362. ISOLATED GROUND RECEPTACLES: HUBBELL #IG -5362. "QUAD" RECEPTACLES: TWO (2) HUBBELL #5362 DUPLEX RECEPTACLES IN A COMMON JUNCTION WITH A 4 GANG COVER PLATE. CASH REGISTER RECEPTACLES: TWO (2) HUBBELL #IG -5362 DUPLEX RECEPTACLES IN A COMMON JUNCTION BOX WITH A 4 GANG COVER PLATE. TELEPHONE /MODEM OUTLETS: HUBBELL TYPE RJ11 WITH COVER PLATE. DATA OUTLETS: HUBBELL TYPE RJ45 WITH COVER PLATE. SINGLE POLE SWITCHES: HUBBELL #HBL -1221. THREE WAY SWITCHES: HUBBELL #HBL- 1223_I. OCCUPANCY SWITCHES: LEVITON, MODEL #PR180 -1 LA OR EQUAL COVERPLATES: HUBBELL, COLOR TO BE COORDINATED WITH OWNER AND /OR ARCHITECT. PUSHBUTTON: EDWARDS #1786C_B. SIGNAL TRANSFORMER: EDWARDS #596. BUZZERS: EDWARDS #15_OAJ. DUCT SMOKE DETECTOR: SIMPLEX #4098 -9686. PORCELEIN CEILING MOUNTED LAMP HOLDER: GENERAL ELECTRIC, MODEL #GE- 5740 -7 FOR USE WITH SWITCH, COMPLETE WITH 100 WATT TYPE "A" LAMP. ELECTRICAL WORK NOTES 1. ENTIRE INSTALLATION SHALL BE MADE IN STRICT ACCORDANCE WITH LANDLORD'S REQUIREMENTS. 2. THE SPACE IS NEW AND HAS NOT PREVIOUSLY BEEN OCCUPIED. REMOVE EXISTING LIGHTING FIXTURES, SWITCHES, JUNCTION BOXES, CONDUIT, WIRE, ETC., NOT REQUIRED FOR THE NEW INSTALLATION. UNUSED FIXTURES SHALL BECOME THE PROPERTY OF THE ELECTRICAL CONTRACTOR AND SHALL BE PROMPTLY REMOVED FROM THE SITE. 3. FURNISH AND INSTALL A NEW 120/208 VOLT 3PH., 4W. 200 AMP SERVICE TO THE SPACE FROM THE LANDLORD ELECTRICAL LOCATION, INCLUDING BUT NOT UMITED TOO, MAIN DISCONNECT, METER, METER SOCKET, CONDUIT, WIRING, ETC. 4. NEW SERVICE SHALL BE A PART OF THE ELECTRICAL CONTRACT. COORDINATE ALL REQUIRED WORK AT DISTRIBUTION LOCATION WITH LANDLORD TO ENSURE COMPATIBILITY/ACCEPTABILITY/AVAILABILITY OF SERVICE AS RE UIRED D INDICATED. Q AN IF ANY ISSUES ARISE WITH REGARD TO SERVICE SIZE AND AVAILABILITY OF CERTAIN SIZED DISTRIBUTION EQUIPMENT, CONTACT ARCHITECT AND /OR ENGINEER PRIOR TO BID FOR DISPOSITION. BASE BID SHALL INCLUDE ALL REQUIRED WORK AT LANDLORD'S DISTRIBUTION LOCATION AND SHALL BE COMPLETE IN EVERY ASPECT AS REQUIRED TO ACCOMMODATE NEW SERVICE. NO EXTRAS WILL BE ALLOWED FOR WORK NOT INCLUDED IN BASE BID. LANDLORD WORK UNDER LANDLORD PERMIT 5. FURNISH AND INSTALL ONE (1) 120/208, 200 AMP, 42 CIRCUIT ELECTRICAL PANEL WITH MAIN LUG ONLY. 6. THE CONTRACTOR SHALL FURNISH AND INSTALL TWO (2) NEW A.C. UNITS ON ROOF ABOVE THE SPACE. ELECTRICAL CONTRACTOR SHALL FURNISH AND INSTALL ALL POWER WIRING, CONDUITS, DISCONNECT SWITCHES, OVERCURRENT PROTECTION, ETC. FOR THE NEW A.C. SYSTEMS AS SHOWN AND REQUIRED FOR A COMPLETE INSTALLATION AS REQUIRED. 7. CONNECT ALL CIRCUITS TO PANEL AS REQUIRED. ALL CIRCUITS SHALL BE ARRANGED ON THE PANEL IN STRICT ACCORDANCE WITH THE NUMBERS SHOWN ON THE DRAWINGS. NO VARIATION OR DEVIATION FROM THE DRAWING WILL BE ACCEPTED. ANY CHANGE IN CIRCUITING DUE TO ACTUAL FIELD CONDITION MUST BE APPROVED BY THE ENGINEER PRIOR TO AFFECTING THE CHANGE. ANY WORK PERFORMED ASIDE FROM THAT SHOWN, INDICATED OR IMPLIED MUST BE APPROVED BY THE PROJECT MANAGER AND /OR ENGINEER BEFORE STARTING. ALL UNUSED CIRCUITS SHALL BE UTIUZED AS SPARES. 8. VERIFY SIZE, LOCATION AND WIRING REQUIREMENTS FOR ALL EQUIPMENT WHICH WILL BE UTILIZED. REPORT ANY DISCREPANCIES, FROM THAT CALLED FOR ABOVE, TO THE ARCHITECT AND /OR ENGINEER FOR DISPOSITION. 9. MAINTAIN ALL REQUIRED CLEARANCES AT ALL ELECTRICAL EQUIPMENT, INCLUDING, BUT NOT UMITED TOO DISCONNECT SWITCH(ES) AND ELECTRICAL PANELS, IN STRICT ACCORDANCE WITH N.E.C. ARTICLE 110. RELOCATE ANY /ALL EQUIPMENT AND ASSOCIATED POWER (INCLUDING RECEPTACLES, WIRING, CONDUIT, ETC.) THAT CONFLICTS WITH THE REUSE OF THIS EQUIPMENT IN THEIR PRESENT LOCATIONS AS REQUIRED. CONTACT THE PROJECT MANAGER TO COORDINATE THIS PORTION OF THE WORK IF REQUIRED. 10.TEMPERATURE CONTROL WORK WILL BE A PART OF THE MECHANICAL CONTRACT. ALL CONTROL WIRING SHALL BE IN CONDUIT. 11.FURNISH AND INSTALL NEW TELEPHONE TERMINAL BOARD IN LOCATION SHOWN. NEW TELEPHONE TERMINAL BOARD SHALL BE 12" X 24" PLYWOOD, 3/4" THICK, MOUNTED ON WALL, READY TO RECEIVE TELEPHONE EQUIPMENT. 12.AFTER CONSTRUCTION IS COMPLETE, FIELD VERIFY THE EXTENT OF ALL EQUIPMENT IN ALL AREAS AND ENSURE THAT ALL CONNECTIONS AND OR INTERFACES BETWEEN DEVICES IN THE VARIOUS AREAS OF THE BUILDING ARE MET AS REQUIRED. CONTACT FIELD REPRESENTATIVE TO COORDINATE THIS PORTION OF THE WORK AS APPLICABLE. 13. PROVIDE TEMPORARY WIRING AS REQUIRED WHILE SERVICE IS BEING INSTALLED TO ALLOW FOR LIGHTING AND POWER FOR CONSTRUCTION PURPOSES. WHEN INSTALUNG NEW SERVICE, KEEP SHUTDOWN TIME TO A MINIMUM. 14. SEE ARCHITECTURAL DRAWINGS FOR UGHT FIXTURE SCHEDULE, EXACT LOCATION OF CEILING GRID, LIGHT FIXTURES, ETC. 15.REFER TO CARTERS RETAIL REQUIRED DELIVERY CONDITION DOCUMENT, SCHEDULE A FOR CLARIFICATION ON ANY ISSUES NOT MENTIONED IN CONTRACT DOCUMENTS. IF CONFLICTS OCCUR BETWEEN CONSTRUCTION DOCUMENTS AND SCHEDULE A, CONTACT THE ARCHITECT AND /OR ENGINEER FOR DISPOSITION PRIOR TO BID OR INSTALLATION. CLARIFICATION TELEPHONE GENERAL NOTES 1. FURNISH AND INSTALL A 2' X 3' X 3/4" TELEPHONE TERMINAL BOARD WITH DEDICATED RECEPTACLE AND CIRCUIT WITH ISOLATED GROUND FOR USE WITH THE TELEPHONE SYSTEM. VERIFY SYSTEM GROUNDING AND ALL OTHER REQUIREMENTS WITH LOCAL TELEPHONE COMPANY. 2. COMMUNICATIONS CONTRACTOR SHALL INSTALL A COMPLETE AND OPERABLE TELEPHONE SYSTEM. SAID CONTRACTOR SHALL SUPPLY ALL LABOR, PREMISE WIRE, WIRE BLOCKS, TELEPHONE JACKS AND OTHER NECESSARY APPURTENANCES TO COMPLETE IN EVERY DETAIL. 3. SYSTEM SHOWN IS SCHEMATIC AND EXACT LOCATION SHALL BE DETERMINED BY ALL SITE CONDITIONS. 4. TELEPHONE CABLES SHALL BE INSTALLED IN CONDUIT (WHERE REQUIRED) ABOVE THE SUSPENDED CEILING. IN INSTANCES WHERE PLENUM INSTALLATIONS ARE ACCEPTABLE - CABLING RUN THROUGHOUT STORE IN THE PLENUM AREA SHALL BE SHIELDED/TEFLON COATED, SUITABLE FOR INSTALLATION IN A PLENUM SPACE - EITHER WAY, ORDERLY RUNS AND ATTACHMENT TO JOISTS ARE REQUIRED. SAID CONTRACTOR SHALL CONFIRM ALL REQUIREMENTS WITH OWNER, GENERAL CONTRACTOR AND LOCAL CODE AUTHORITY BEFORE INSTALUNG ANY CABLE. 5. OWNER WILL HAVE A FIVE (5) LINE SYSTEM. COORDINATE ALL REQUIREMENTS WITH THE LOCAL UTILITY. A. LINES 1 THROUGH 5 WILL BE USED FOR VOICE, FAX OR MODEM AS DIRECTED BY THE OWNER. REFERENCES TO NUMBERS 6 -8 (9) ON THE SCHEMATICS ARE FOR OTHER LOW VOLTAGE SYSTEMS IN THE SPACE PROVIDED BY OTHERS. 6. GENERAL CONTRACTOR SHALL PROVIDE TEMPORARY TELEPHONE SERVICE FOR USE BY OWNER AND SELF DURING CONSTRUCTION. CONNECTION FEES AND SERVICE FEES SHALL BE PAID BY GENERAL CONTRACTOR. 7. GENERAL CONTRACTOR SHALL COORDINATE WITH THE OWNER AND LOCAL UTILITY COMPANY (IF REQUIRED) TO SUPPLY THE TELEPHONES THROUGHOUT THE SPACE FOR THE PROJECT. ELECTRICAL WORK NOTES - GENERAL 1. THE ENTIRE INSTALLATION SHALL BE MADE IN STRICT ACCORDANCE WITH THE LANDLORD'S REQUIREMENTS. 2. ELECTRICAL WORK SHALL BE COMPLETE IN EVERY DETAIL AND ALL MISCELLANEOUS ITEMS OF MATERIAL AND LABOR NECESSARY TO COMPLETE THE WORK DESCRIBED, SHOWN OR REASONABLY IMPUED ON DRAWINGS OR SPECIFICATIONS SHALL BE INCLUDED IN THE CONTRACT. CONTRACTOR SHALL MAKE MINOR ADJUSTMENTS TO THE WORK WHERE REQUESTED BY THE TENANT, WHEN SUCH ADJUSTMENTS ARE NECESSARY TO PROPER OPERATION AND WITHIN THE INTENT OF THE CONTRACT. 3. ELECTRICAL CONTRACTOR SHALL VISIT THE SITE AND VIEW ALL EXISTING CONDITIONS BEFORE SUBMITTING A PROPOSAL FOR THE WORK AS DESCRIBED AND SHOWN. NO EXTRAS WILL BE ENTERTAINED FOR FAILURE TO MAKE THIS VISIT. 4. ELECTRICAL CONTRACTOR SHALL ACCEPT SOLE AND COMPLETE RESPONSIBILITY FOR CONDITIONS OF THE JOB SITE, INCLUDING SAFETY OF ALL PERSONS AND PROPERTY DURING PERFORMANCE OF THE WORK. 5. CONFORM TO GENERAL CONTRACTOR'S SCHEDULE AND INSTRUCTIONS THROUGHOUT THE DURATION OF THE PROJECT AS REQUIRED TO COMPLY IN EVERY WAY NECESSARY. AT NO TIME SHALL ANY WORK BE UNDERTAKEN WHICH SHALL INTERFERE WITH THE NORMAL OPERATION OF BUSINESS. ANY SHUTDOWN MUST OCCUR AFTER REGULAR BUSINESS HOURS AND MUST BE CLEARED WITH THE MANAGEMENT WITH PROPER PRIOR NOTICE GIVEN TO THE OWNER'S REPRESENTATIVE. 6. CONTRACTOR SHALL NOTIFY THE ARCHITECT AND /OR ENGINEER OF ERRORS, OMISSIONS OR DISCREPANCIES BEFORE CONSTRUCTION OR FABRICATION OF AFFECTED WORK, OR, FAIUNG SUCH NOTICE, SHALL BE RESPONSIBLE FOR CORRECTING SAME WITHOUT COST TO TENANT, ARCHITECT OR ENGINEER. 7. ORDER EQUIPMENT ON A TIMELY BASIS (WITHIN 5 DAYS OF RECEIPT OF CONTRACT) TO MAINTAIN CONSTRUCTION SCHEDULE. 8. SUBMIT FIVE (5) COPIES OF SHOP DRAWINGS OF ALL EQUIPMENT FOR REVIEW BY THE ENGINEER /ARCHITECT. ONE (1) COPIES WILL BE RETAINED FOR RECORD. ONLY FURNISH SYSTEMS, EQUIPMENT AND MATERIAL IN COMPLIANCE WITH APPROVED SHOP DRAWINGS. 9. WORK SHALL INCLUDE STARTUP OF ALL SYSTEMS, FURNISHING OF OPERATING AND MAINTENANCE INSTRUCTIONS, WARRANTEE FOR ALL EQUIPMENT AND ONE YEAR GUARANTEE OF ALL WORKMANSHIP, COMMENCING ON DATE OF ACCEPTANCE BY THE TENANT. 10.WORK SHALL ALSO INCLUDE FULL ONE (1) YEAR MAINTENANCE, PARTS AND SERVICE CONTRACT FOR ALL EQUIPMENT FURNISHED UNDER THE CONTRACT. 11.ALL WIRE SHALL BE COPPER. MINIMUM SIZE #12 AWG. ALL CONDUCTORS #10 AND SMALLER SHALL HAVE TYPE "THHW" INSULATION. CONDUCTORS LARGER THAN #10 SHALL HAVE TYPE "THHN" INSULATION. 12.ALL WIRE SHALL BE IN CONDUIT AND SHALL BE CONCEALED FROM VIEW. EXPOSED CONDUIT SHALL BE INSTALLED IN STRAIGHT LINES PARALLEL WITH OR PERPENDICULAR TO COLUMN ONES OR BEAMS AND SHALL BE SEPERATED BY AT LEAST 3" INCHES FROM DOMESTIC WATER LINES WHENEVER ALONG SIDE OR ACROSS SUCH ONES. ROMEX IS NOT PERMITTED. FLEXIBLE CONDUIT OR TYPE MC CABLE MAY BE USED FOR FIXTURE AND EQUIPMENT CONNECTIONS ONLY, AND WHERE SO USED SHALL BE GROUNDED WITH A SEPERATE FULL SIZED GREEN GROUNDING CONDUCTOR. FLEXIBLE CONDUIT CONNECTIONS SHALL BE UMITED TO 3' -0" IN LENGTH. CONDUIT EXPOSED TO WEATHER SHALL BE RIGID. ALL OTHER CONDUIT SHALL BE EMT. CONDUIT FITTINGS SHALL BE COMPRESSION OR THREADED TYPE, USE OF SET SCREW FITTINGS IS NOT ACCEPTABLE. 13.CONDUIT IN FINISHED AREAS SHALL BE CONCEALED. CONDUIT IN UNFINISHED AREAS MAY BE EXPOSED. 14.HOME RUNS OVER 100' IN LENGTH SHALL BE #10 WIRE. 15.CONTRACTOR SHALL ENSURE THAT ENTIRE INSTALLATION IN ACCORDANCE WITH N.E.C. ARTICLE 110 -26 AND THAT ALL REQUIRED OPERATING AND MAINTENANCE CLEARANCES ARE MAINTAINED AND ACCOUNTED FOR. ADJUSTMENTS TO LAYOUT SHOWN TO ACCOMMODATE CLEARANCE REQUIREMENTS SHALL BE DISCUSSED WITH ARCHITECT AND /OR ENGINEER SO AS TO MINIMIZE IMPACT ON OTHER SYSTEMS. CONTACT ARCHITECT AND /OR ENGINEER FOR DISPOSITION. 16.CONTRACTOR SHALL OBTAIN AVAILABLE FAULT CURRENT RATING AND PROVIDE PROTECTION FOR MAIN CIRCUIT BREAKER AND BRANCH DEVICES AS REQUIRED. 17.SEAL ALL PENETRATIONS THROUGH WALLS, CEILINGS, FLOORS, ETC. SO THAT THEY ARE AIR, WATER AND FIRE TIGHT. 18.PROVIDE ENGRAVED BAKEUTE NAMEPLATES FOR ALL ELECTRICAL SERVICE EQUIPMENT INCLUDING DISCONNECT SWITCHES, PANELS, PUSHBUTTONS AND STARTERS. 19.LIGHTING CIRCUITS WHICH ARE SWITCHED AT PANELS SHALL BE FITTED WITH TYPE "SWD" BREAKERS SUITABLE FOR SWITCHING SERVICE. 20.FURNISH AND INSTALL TYPEWRITTEN PANEL DIRECTORY(IES). IDENTIFY AND LABEL ALL ELECTRICAL SERVICE EQUIPMENT. FURNISH AND INSTALL AN ENGRAVED NAMEPLATE ON THE WALL ABOVE THE SINGLE RECEPTACLE IN THE REAR AREA FOR HANDHELD STEAMER IDENTIFYING IT AS SUCH. 21.FURNISH TWO (2) COPIES OF THE ELECTRIC RISER DIAGRAM AND PANEL DIRECTORY(IES) TO THE TENANT FOR REVIEW AND APPROVAL, OR SUBMIT A LETTER TO THE TENANT CONFIRMING THAT THE SYSTEM WAS INSTALLED AS PER PLANS AND SPECIFICATIONS. 22.FURNISH ALL EQUIPMENT MANUALS AND WARRANTIES TO TENANT AT THE COMPLETION OF THE PROJECT. 23.FURNISH AND INSTALL PANEL LOCKS WHERE SHOWN ON THE DRAWINGS. 24.WIRE EMERGENCY BALLAST AND BATTERY LIGHTS ON SAME CIRCUIT IN AREA AND AHEAD OF LOCAL SWITCHING. 25.EXTERIOR SIGNAGE WILL BE FURNISHED AND INSTALLED BY SIGN CONTRACTOR. CONNECT TO SIGNS AND PROVIDE POWER AS REQUIRED FOR A COMPLETE INSTALLATION. COORDINATE THIS PORTION OF THE WORK WITH THE SIGN CONTRACTOR AND LANDLORD AS REQUIRED. 26.SOME LIGHTING FIXTURES WILL BE FURNISHED BY THE OWNER. PROCURE UGHTING FIXTURES FROM OWNER AND INSTALL THEM IN THE LOCATIONS SHOWN AS REQUIRED. CONTACT THE OWNER'S REPRESENTATIVE PRIOR TO SUBMITTING A PROPOSAL TO DETERMINE WHICH FIXTURES (IF ANY) ARE NOT FURNISHED BY THE OWNER. INSTALL ALL FIXTURES (OWNER FURNISHED AND CONTRACTOR FURNISHED) AS REQUIRED FOR A COMPLETE INSTALLATION. LEAVE PROTECTIVE COVERING /FILM IN PLACE ON FIXTURES UNTIL FINAL CLEAN -UP. INSTALL LIGHTING FIXTURES IN RATED CEILING SO AS TO MAINTAIN INTEGRITY OF RATING. REPLACE ANY LAMPS THAT HAVE EXPIRED DURING CONSTRUCTION AND MAKE ALL ADJUSTMENTS TO FIXTURES FOR DIRECTION AS REQUIRED PRIOR TO COMPLETION. 27.SWITCHES, NOT OTHERWISE CALLED OUT, SHALL BE MOUNTED 4'_6" ABOVE FLOOR. 28.RECEPTACLES AND TELEPHONE OUTLETS IN SALES AREA SHALL BE MOUNTED AT 18" A.F.F. UNLESS NOTED. RECEPTACLES AND COVERS SHALL BE AS CALLED FOR IN THE SPECIFICATIONS. 29.ALL COVERPLATES FOR ALL DEVICES SHALL BE AS REQUIRED TO MATCH ADJACENT FINISHES - COORDINATE WITH ARCHITECT. 30.VERIFY EXACT LOCATION OF OUTLETS AND DEVICES WITH OWNER'S REPRESENTATIVE PRIOR TO INSTALLATION. FURNISH AND INSTALL OUTLET BOXES, DEVICES, COVERPLATES AND FLANGES AS REQUIRED. 31.IG AND GFI RECEPTACLES SHALL BE RATED AT 20 AMPERES AND SHALL HAVE A DEDICATED INSULATED GREEN GROUND WIRE, THE GROUND WIRE SHALL BE RUN CONTINUOUS AND UNSPUCED BETWEEN THE DEVICE AND THE PANEL GROUND BUS. 32.MOUNTING HEIGHTS OF EQUIPMENT NOT SPECIFICALLY CALLED FOR ARE NOTED ON ARCHITECTURAL DRAWINGS - SEE ARCHITECTURAL DRAWINGS TO COORDINATE. 33.SUPPORT ALL FIXTURES ACROSS CEILING TEES OR FROM STRUCTURE ABOVE. IN NO CASE SHALL CEILING TILES OR PLASTER CEILING SUPPORT ANY FIXTURES. 34.SEE ARCHITECTURAL DRAWINGS FOR EXACT LOCATION OF CEIUNG GRID, UGHT FIXTURES, ETC. AND SYMBOLS LIST, FIXTURE SCHEDULE, NOTES AND OTHER SPECIFICATION REQUIREMENTS. 35.THE OWNER WILL FURNISH AND INSTALL A COMPUTER SYSTEM (CASH REGISTERS AND COMPUTERS) FOR THE SPACE. CONTRACTOR SHALL FURNISH AND INSTALL CONDUITS WITH CATEGORY 5 CABLING FROM ONE LOCATION TO ANOTHER (VARIOUS PLACES) IN ALL LOCATIONS SHOWN ON THE DRAWINGS - EITHER IN PLAN OR IN THE SCHEMATIC WIRING DIAGRAM DETAIL. CATEGORY 5 CABLING PROVIDED SHALL BE PROVIDED WITHOUT CONNECTORS ON THE ENDS AND WITH 10' -0" SLACK WHIPS AT EACH END FOR OWNER'S USE (VENDOR WILL ULTIMATELY MAKE CONNECTIONS). IN INSTANCES WHERE PLENUM INSTALLATIONS ARE ACCEPTABLE - CABLEING RUN THROUGHOUT STORE IN THE PLENUM AREA SHALL BE SHIELDED/TEFLON COATED, SUITABLE FOR INSTALLATION IN A PLENUM SPACE. 36.THE OWNER WILL FURNISH AND INSTALL A TRAFFIC COUNTER SYSTEM (SHOPPERTRAK - ORBIT SYSTEM) FOR THE SPACE. CONTRACTOR SHALL FURNISH AND INSTALL CONDUITS WITH CATEGORY 5 CABLING FROM ONE LOCATION TO ANOTHER (VARIOUS PLACES) IN ALL LOCATIONS SHOWN ON THE DRAWINGS - EITHER IN PLAN OR IN THE SCHEMATIC WIRING DIAGRAM DETAIL CABLE SHALL INSTALLED WITH 15' -0" TO 20' -0" SLACK AT EACH END. CATEGORY 5 CABLEING SHALL BE AS FOLLOWS: 4 PAIRS, 24 AWG, SOLID CONDUCTORS, TWISTED PAIRS, 7 X 32 TINNED COPPER, 12.5 Pf, 110 OHMS, CL2 PLENUM RATED - BERK -TEK CABLE #230247 (SOUD PLENUM) OR BELDEN CABLE #1701A (BONDED, SOLID TWISTED PAIRS, PLENUM) OR EQUAL. IN INSTANCES WHERE PLENUM INSTALLATIONS ARE ACCEPTABLE - CABLEING RUN THROUGHOUT STORE IN THE PLENUM AREA SHALL BE AS MENTIONED BEFORE AND SHIELDED/TEFLON COATED, SUITABLE FOR INSTALLATION IN A PLENUM SPACE. 37.GENERAL PURPOSE RECEPTACLES SHALL BE MOUNTED 18" ABOVE FINISHED FLOOR AS REQUIRED WITH THE ELECTRICAL FEEDS TO EACH RECEPTACLE INSTALLED DOWN IN THE WALL. SEE ARCHITECTURAL DRAWINGS FOR ALL HEIGHTS, DIMENSIONS AND CONFIGURATIONS OF DEVICES NOT INDICATED ON THESE DRAWINGS. REFERENCE SAME DRAWINGS FOR EQUIPMENT NOT IDENTIFIED. 38.VERIFY EXACT LOCATION OF OUTLETS AND DEVICES WITH OWNER'S REPRESENTATIVE PRIOR TO INSTALLATION. FURNISH AND INSTALL OUTLET BOXES, DEVICES, COVERPLATES AND FLANGES AS REQUIRED. 39.SUPPORT ALL FIXTURES WITH UNISTRUT AS REQUIRED. 40. NOT USED. 41.WORK SHALL INCLUDE STARTUP OF ALL SYSTEMS, FURNISHING OF OPERATING AND MAINTENANCE INSTRUCTIONS, AND ONE YEAR GUARANTEE, COMMENCING ON DATE OF ACCEPTANCE BY THE TENANT. 42. FURNISH ALL MATERIAL AND EQUIPMENT AS SPECIFIED, EXCEPT WHERE SPECIFIC APPROVAL FOR SUBSTITUTION IS GIVEN BY THE TENANT. 43.PROPOSAL SHALL BE BASED ON SPECIFIED MATERIAL AND EQUIPMENT. IN ORDER TO PROMOTE COMPETITION, HOWEVER, BIDDERS ARE ENCOURAGED TO SUBMIT ALTERNATE PROPOSALS ON ANY ALTERNATE MATERIALS AND /OR EQUIPMENT THEY WISH TO PROPOSE, INCLUDING ANY PRICE CHANGES EFFECTED BY ACCEPTANCE OF ALTERNATES. 44.COST OF ANY CHANGES REQUIRED BY OTHER TRADES DUE TO SUBSTITUTION OF ALTERNATE EQUIPMENT SHALL BE INCLUDED IN THE ALTERNATE PROPOSAL 45.ALTERNATE PROPOSALS WILL BE ACCEPTED OR REJECTED BEFORE ISSUANCE OF CONTRACTS. NO CHANGES WILL BE ALLOWED AFTER THE CONTRACT IS SIGNED. 46.UPON COMPLETION OF WORK, PREPARE LIGHTING AND POWER PROJECT RECORD AS- BUILTS. PRESENT THE COMPLETED DRAWINGS TO THE OWNER. AS -BUILT DRAWINGS SHALL INCLUDE ALL BRANCH CIRCUIT WORK, ANY PANELBOARD INFORMATION, FINAL SWITCHING, ETC. 47.ALL PENETRATIONS THROUGH FIRE RATED ASSEMBLIES SHALL BE FIRE PROOFED TO THE SAME OR GREATER RATING THAN THAT OF THE ASSEMBLY. WHERE CONFLICT OCCURS, NOTIFY THE ARCHITECT. 48.ALL FUSES 600 AMPERES OR LESS SHALL BE UL LISTED, CLASS RK1 OR J, LOW -PEAK, DUAL ELEMENT, TIME DELAY, 600 VOLT. ACCEPTABLE MANUFACTURES ARE BUSSMAN, GOULD OR SHAWMUT. 49.VERIFY LOCAL CONDITIONS AT SITE. 50.COMPLY WITH ALL APPLICABLE CODES. 51.SECURE AND PAY FOR ALL REQUIRED PERMITS 52.THE TENANT MAY HIRE AN INDEPENDENT CONTRACTOR /INSPECTOR TO VERIFY THE PROPER INSTALLATION OF THE COMPLETE ELECTRICAL SYSTEM AS PER PLANS AND SPECIFICATIONS. SHOULD THERE BE ANY DISCREPANCIES IN THE INSTALLATION, THE CONTRACTOR WILL BE NOTIFIED IN WRITING AND HAVE TEN (10) WORKING DAYS TO RECTIFY THE ERRORS. IF THE TENANT DECIDES IT IS NECESSARY TO VERIFY THAT THE DEFICIENCIES HAVE BEEN CORRECTED BY MEANS OF A REINSPECTION, THE COST OF A REINSPECTION (PLUS 10 %) WILL BE DEDUCTED FROM THE FINAL CONTRACT INVOICE. A F A 'g9 4 19 k% i bk 4 /1/0 QC/i 44 RECEIVED CITY OF TUKWILA DEC ?. 2 ?I109 PERMIT CENTER DATE: 11/15 /09 JOB NO: 09 - 066 DRAWN: STAFF CHECKED: DP Q -0 WO- CC Q W 0 Z co r COWCo CCU W =4 Z " W 0 <O I- ' O ^ V � LO cd O cn r 1' co SHEET TITLE SCALE 1/4 "=1' - O' E5.0 SHEET NUMBER STORE HUMBER %TBD REVISIONS 'A' - ISSUE 1\ LANDLORD WORK UNDER LANDLORD PERMIT DATE 12/6/09 '8' -ISSUE DATE 'G' -ISSUE PATE ELECTRICAL SPECIFICATIONS FAN SCHEDULE (BY LANDLORD) UNIT NO. MANUFACTURER MODEL CFM PRESSURE DROP INCHES WC. DRIVE WATTS /HP RPM VOLTAGE CONTROL NOTES EF -1 GREENHECK SP -7 100 1/8" DIRECT 80 W. 950 120 SWITCH 1 EF -2 GREENHECK SP -7 100 1/8" DIRECT 80 W. 950 120 SWALL CIT H 1 NOTES; FAN WITH INTEGRAL BACKDRAFT DAMPER(AS REQ.) & DISCONNECT SWITCH. 1. COMPLETE HVAC UNIT SCHEDULE (BY LANDLORD) MARK NEW A.C. UNIT 11 NEW A.C. UNIT 12 MFR. AND MODEL NO. TRANE YSC092 TRANE YSCO60 NOMINAL TONS 7.5 5 SA CFM 3000 2000 OSA CFM 700 310 COOLING CAPACITY SENSIBLE (MBH) 70.92 45.84 TOTAL (MBH) 88.95 58.28 SEER/ EEROARI 11.2 13.0 HEATING CAPACITY INPUT (MBH) 120 60 OUTPUT (MBH) 97.2 48.0 ELECTRICAL VOLT 208 208 PH. 3 3 EVAP. FAN FLA 6.3 5.0 COMPRESSORS QTY. 2 1 RLA 11.9 10.2 17.6 LRA CONDENSER FAN QTY. 1 1 HP FLA 3.85 2.50 MIN. CIRCUIT 43.30 29.50 APPROX. OPER. (LEIS.) 1428 825 REMARKS 1O LOW AMBIENT CONTROL TO 0' 0 STANDARD EFFICENCY MODEL COMPLETE WITH ECONOMIZER CYCLE AND ALL FACTORY SAFETY AND OPERATING CONTROLS O PROVIDE 5 YEAR COMP. WARRANTY ® CONTRACTOR MAY SUBSTITUTE EQUIPMENT OF ANOTHER MANUFACTURER PROVIDED IT MEETS THE RATED CAPACRIES AND DESIGN REQUIREMENTS OF THE SCHEDULED OR SPECIFIED EQUIPMENT SUBJECT TO THE APPROVAL OF THE ENGINEER. SUBSTITUTE EQUIPMENT SHALL NOT EXCEED ELECTRICAL O PROVIDE 2" THICK THROWAWAY FILTERS REQUIREMENTS OR PHYSICAL SIZE OF SCHEDULED EQUIPMENT. MECHANICAL CONTRACTOR SHALL BE RESPONSIBLE FOR COORDINATING M.O.C.P. WITH ELECTRICAL CONTRACTOR FOR ANY EQUIPMENT SUBSTITUTIONS. 0 PROVIDE VIBRATION ISOLATORS FOR CURB MOUNTING AND ROOF CURB AS REQUIRED AIR DEVICE SCHEDULE (BY LANDLORD) MARK A B C D E F G SERVICE SUPPLY SUPPLY SUPPLY SUPPLY RETURN RETURN RETURN/ TRANSFER TYPE SQUARE SQUARE SQUARE RECETANGLE SQUARE SQUARE SQUARE MODULE /FACE SIZE 24" X 24- 24" X 24" 12" X12" 8" X6" BORDER 24" X 24" 12" X 12" SEE PLAN ( +2" EA. DIM.) BACKPAN 18'X18" 18"X18" 9"X9" CORE AREA SEE PLAN SEE PLAN SEE PLAN MFGR. & MOD. NO. TITUS TDCA TUTUS TDCA TITUS TDCA TUTUS 272RS TUTUS 50F TUTUS 5OF TUNS 350FL BORDER TYPE 3 - LAY-IN 3 - LAY-IN 3 - LAY-IN 1 3 - LAY-IN 3 - LAY-IN 1 - SURFACE PATTERN 4 -WAY 2 -WAY STRAIGHT 2 -WAY CORNER DOUBLE DEFLECTION NOTES 2,4,7 2,4,7 2,4,7 1,7,9 10 10 10 COMMENTS COMPLETE WITH SHEET METAL, WALL SLEEVE AND TAMPER PROOF SCREEN NOTES: 1. PROVIDE WITH AG -35 -AA OPPOSED BLADE VOLUME DAMPER (RECT. 272RS & 23RL) 2. PROVIDE WITH MODEL EG EQUALIZING GRID 3. PROVIDE WITH MODEL AG -95 OPPOSED BLADE VOLUME DAMPER (SQUARE) 4. PROVIDE WITH MODEL AG -75 OPPOSED BLADE VOLUME DAMPER (ROUND) 5. PROVIDE WITH TRM PLASTER FRAME 6. PROVIDE WITH RUSKIN MODEL CFD ARE DAMPER 7. LIMIT FLEXIBLE DUCT CONNECTION TO 5' -0" MAXIMUM 8. PROVIDE WITH TITUS MODEL MPI37 INSULATED PLENUM (DO NOT SUPPLY FOR BLANK SECTIONS) 9. PROVIDE PREFAB PLASTER FRAME FOR MOUNTING 10. PROVIDE WITH MODEL AG -15 -AA VOLUME DAMPER (RETURN RECT. 50F) AIR QUANTITY (CFM) FLEXIBLE DUCT CONNECTION SIZE SYMBOLS AND ABBREVIATIONS CFM CD RAR S.A. R.A. O.A. F O EX EXR N V. W. D.C.W. H.W. CUBIC FEET PER MINUTE CEILING DIFFUSER RETURN AIR REGISTER SUPPLY AIR RETURN AIR OUTDOOR AIR THERMOSTAT SMOKE DETECTOR EXISTING TO REMAIN EXISTING RELOCATED NEW VENT WASTE DOMESTIC COLD WATER HOT WATER SPRINKLER NOTES (BY LL): -WITH REGARD TO OBSTRUCTIONS TO SPRINKLER HEADS - GENERAL CONTRACTOR IS RESPONSIBLE FOR A COMPLETE AUTOMATIC FIRE PROTECTION SPRINKLER SYSTEM, INCLUDING SPRINKLER MAINS, BRANCHES, HEADS, ETC. - ADDITIONAL HEADS MAY BE REQUIRED OUTSIDE THE 'NORMAL' PATTERN TO HELP ACCOUNT FOR OBSTRUCTIONS FROM FLOOR (PARTITION WALLS) & CEILING - PLEASE CHECK REQUIREMENTS OF ANY ADDITIONAL HEADS TO COMPLY WITH NFPA 13, SECTION 5- 6.5.1.2 & 5- 6.5.2.3 AS REQUIRED. - CERTIFIED SPRINKLER CONTRACTOR SHALL SUBMIT ACTUAL DESIGN DRAWINGS AS REQUIRED BY ALL REVIEWING AGENCES - LAYOUT SHOWN IS TO BE USED AS A GUIDELINE ONLY AND REPRESENTS A MINIMUM INSTALLATION FURNISH AND INSTALL NEW GAS METER ON REAR OF BUILDING TO SERVE SPACE AS REQUIRED. (BY LL) 12X12 NEW (BA AND UNIT 2 SA TO 2 310 C N ROC F 00 CFH 24X24 EXTE CON VERI LOCA (TYPI D AND CONNECT NEW 1" ENSATE DRAIN TO SANITARY. EXACT CONNECTION ION IN FIELD. AL FOR 2 -BY LL) -NEW S IN RA (TYPICA A.C. UNIT ; 1 ON ROOF LANCE SA TO 3000 CFM D OA TO 700 CFM) �. OKE DETECTOR UCT FOR 2 -BY LL) NEW 8"93 TOILET EXHAUST DUCT UP THROUGH ROOF (BY LL) EX. TENANT GAS STUB IN SPACE VERIFY EXACT LOCATION IN FIELD (BY LL) 24X24 NEW 1/2" GAS PIPE TO LANDLORD PROVIDED GAS METER - SEE NOTE 2 NOTE 1: FURNISH AND INSTALL GAS COCK /SHUTOFF /PRESSURE REGULATOR AT A.C. UNIT AS REQUIRED NOTE 2: GAS PIPING SIZE BASED ON ASSUMED TOTAL LENGTH OF 100' -0" ® 2 PSI - ADJUST AS REQUIRED FOR DIFFERENT LENGTH SUBSTITUTION OF ROUND DUCTWORK IS ACCEPTABLE ALL WORK COMPLETED SHALL COMPLY WITH THE 2006 WASHINGTON STATE ENERGY CODE INCLUDING THE COMMISSIONING REQUIREMENTS OF SECTION 1416.2 IF APPLICABLE. FLOOR PLAN - MECHANICAL WORK SCALE. 1/4 - 1 LIGHTS HAVE BEEN REMOVED FOR CLARITY PURPOSES - SEE ARCH. RCP AND /OR SHEET E1.0 FOR EXACT LOCATIONS OF LIGHTING FIXTURES. A LANDLORD WORK UNDER LANDLORD PERMIT 6 9 RECEIVED CITY OF TUKWILA DEC 2 2 2009 PERMIT CENTER DATE: 11/i/09 JOB NO: 09 -066 DRAWN: STAFF CHECKED: PP 'B' -ISSUE PATE 'C' -ISSUE PATE W CC cc d�o COWco Wi<4 Z c s I 0 <CZ ca N � y, T r V, S1ORE NUMBER #TBD SHEET TITLE REVISIONS 'A'- ISSUE LANDLORD WORK UNDER LANDLORD PERMIT DATE 12/6/09 FLOOR PLAN MECHANICAL WORK SCALE 1/4' -1' - 0' SHEET NUMBER M1.0 MECHANICAL EQUIPMENT AND MATERIAL A.C. UNITS: SEE A.C. UNIT SCHEDULE. A.C. UNIT CONTROLS (WALL MOUNTED THERMOSTAT): LIGHTSTAT, MODEL# THE -POI SETBACK THERMOSTAT. EXHAUST FANS: SEE EXHAUST FAN SCHEDULE. CEILING DIFFUSERS: SEE AIR DEVICE SCHEDULE. RETURN AIR REGISTERS: SEE AIR DEVICE SCHEDULE. DUCTWORK: RIGID: GALVANIZED SHEET METAL, IN ACCORDANCE WITH ASHRAE AND SMACNA REQUIREMENTS FOR LOW PRESSURE DUCTWORK (1" WC). FLEXIBLE (IF USED): WIREMOLD TYPE WCK OR EQUAL FLEXIBLE CLASS 1 AIR DUCT, METALIZED POLYESTER FILM LAMINATED ON STEEL WIRE REINFORCING, WITH 1.5" THICK, 3/4 LB DENSITY FIBERGLASS INSULATION AND FIRE RETARDENT REINFORCED VAPOR BARRIER (HI- VINYL) AND SHALL MEET NFPA 90A AND UL STANDARD 181. DUCTWORK INSULATION (SUPPLY): WRAP IN ACCORDANCE WITH THE FOLLOWING: WRAP: 1.5" THICK, 3/4 LB. DENSITY FIBERGLASS INSULATION WITH VAPOR BARRIER JACKET. MECHANICAL WORK NOTES 1. ENTIRE INSTALLATION SHALL BE MADE IN STRICT ACCORDANCE WITH LANDLORD'S REQUIREMENTS. 2. THE SPACE IS NEW AND HAS NOT PREVIOUSLY BEEN OCCUPIED. REMOVE ALL EQUIPMENT, DUCTWORK, PIPING, DIFFUSERS, ETC., IN THE SPACE PRESENTLY AND NOT REQUIRED FOR THE NEW INSTALLATION. 3. FURNISH AND INSTALL ONE (1) NEW TOILET EXHAUST FAN IN EACH TOILET ROOM AND EXTEND DUCT TO EXISTING LANDLORD PROVIDED TOILET EXHAUST DUCT AS SHOWN. 4. FURNISH AND INSTALL TWO (2) NEW A.C. UNITS ON THE ROOF (SEE SCHEDULE FOR SIZING, MAKE, MODEL, ETC.) IN THE LANDLORD'S PRE - DESIGNATED AREAS (VERIFY LOCATION IN FIELD - THERE ARE FOUR (4) PAINTED AREAS ON THE ROOF DECK FROM BELOW, TWO (2) LOCATIONS HAVE BEEN SELECTED FOR USE) FOR THE SPACE INCLUDING BUT NOT LIMITED TOO, DUCTWORK THROUGHOUT THE SPACE, DIFFUSERS, REGISTERS, ETC. 5. MECHANICAL CONTRACTOR SHALL BE RESPONSIBLE FOR MODIFYING THE EXISTING ROOF STRUCTURE AS REQUIRED TO ACCOMMODATE THE NEW INSTALLATIONS. MECHANICAL CONTRACTOR SHALL ENLIST THE SERVICES OF A REGISTERED PROFESSIONAL STRUCTURAL ENGINEER TO REVIEW AND CERTIFY THE PROPOSED MODIFICATIONS PRIOR TO AFFECTING ANY WORK, IF REQUIRED. ANY DRAWINGS AND /OR SPECIFICATIONS REQUIRED BY THE BUILDING DEPARTMENT AND /OR LANDLORD FOR THE PROPOSED MODIFICATIONS SHALL BE PROVIDED BY THE MECHANICAL CONTRACTOR. ANY AND ALL DESIGN, CERTIFICATION AND SUBMITTALS REQUIRED FOR THIS WORK SHALL BE BY THE CONTRACTOR AT THE CONTRACTOR'S EXPENSE. 6. FURNISH AND INSTALL NEW DUCTWORK, DIFFUSERS AND REGISTERS AS SHOWN AND SPECIFIED. FURNISH AND INSTALL VOLUME DAMPERS AT ALL NEW BRANCH TAKEOFFS. 7. ALL NEW SUPPLY AIR DUCTWORK SHALL BE WRAPPED WITH THE INSULATION SPECIFIED ABOVE. WRAP SHALL BE INSTALLED IN STRICT ACCORDANCE WITH MANUFACTURER'S RECOMMENDATIONS. DUCT SIZES SHOWN ARE INSIDE CLEAR DIMENSION AND SHALL BE ADJUSTED IF REQUIRED TO ACCOUNT FOR METHOD OF INSULATION. 8. DUCT SIZES SHOWN ARE INSIDE CLEAR DIMENSION AND SHALL BE ADJUSTED IF REQUIRED TO ACCOUNT FOR METHOD OF INSULATION. 9. TEMPERATURE CONTROLS, INCLUDING WIRING, SHALL BE PART OF THE MECHANICAL CONTRACT. FURNISH AND INSTALL IN LOCATIONS SHOWN. 10.FIBERGLASS DUCTWORK IS NOT PERMITTED. 11.FLEXIBLE DUCTWORK MAY BE USED FOR VERTICAL DIFFUSER CONNECTIONS ONLY AND SHALL BE LIMITED IN LENGTH TO 5' -0" MAX. 12.ALL DUCTWORK SHALL CONFORM TO THE LATEST EDITION OF SMACNA STANDARDS AND RECOMMENDATIONS. 13.FIRE STOP ALL PENETRATIONS THROUGH FIRE RATED PARTITIONS (IF REQUIRED) IN STRICT ACCORDANCE WITH ALL APPLICABLE STATE AND LOCAL CODES. VERIFY EXACT METHOD OF FIRE AND MOISTURE CONTROL WITH LANDLORD AND /OR ARCHITECT. 14.SEE ARCHITECTURAL DRAWINGS FOR LIGHT FIXTURE SCHEDULE, EXACT LOCATION OF CEILING GRID, LIGHT FIXTURES, ETC. FIRE PROTECTION WORK 1. FIRE PROTECTION WORK SHALL BE A PART OF THE MECHANICAL CONTRACT. THE SPRINKLER SYSTEM SHALL BE INSTALLED AS REQUIRED TO ACCOMMODATE NEW PARTITIONING AND NEW CEILINGS. SPRINKLER HEAD LOCATIONS SHALL BE REVIEWED AND APPROVED BY A CERTIFIED SPRINKLER SUBCONTRACTOR PRIOR TO INSTALLATION, ETC. SPRINKLER SUBCONTRACTOR SHALL FURNISH AND INSTALL NEW AS REQUIRED. ADJUST INSTALLATION AS DESCRIBED BELOW FOR PROPER COVERAGE, MINIMUM INSTALLATION REQUIREMENTS, ETC. 2. ALL SPRINKLER HEADS IN AREAS WITH FINISHED CEILINGS ("PUBLIC" AREAS - SALES AREA, FITTING ROOMS, ETC.) SHALL BE SEMI - RECESSED PENDANT TYPE WITH WHITE FINISH. SPRINKLER HEADS IN "WORK" AREAS (STOCK ROOM, TOILET ROOM, ETC.) SHALL BE ROUGH BRASS PENDANT TYPE WITH HEAD GUARDS. 3. COVERAGE FOR THE SPRINKLER HEADS SHOWN SHALL BE NO GREATER THAN 130 SF AND SHALL BE VERIFIED BY A CERTIFIED SPRINKLER SUBCONTRACTOR. 4. CERTIFIED SPRINKLER SUBCONTRACTOR SHALL INCLUDE LAYOUT DRAWINGS AND ALL REQUIRED LANDLORD AND AGENCY APPROVALS AS PART OF HIS WORK. SPRINKLER SUBCONTRACTOR'S SUBMITTAL SHALL INCLUDE, BUT NOT BE LIMITED TO, THE FOLLOWING AS REQUIRED TO OBTAIN ALL APPROVALS: A. SPECIFICATIONS FOR ALL PIPING, PIPE FITTINGS, GATE VALVES, DRAIN VALVES, CHECK VALVES, PIPING SUPPORTS, VALVE HOSE CONNECTIONS, ALL IDENTIFICATION AND SIGNAGE AS REQUIRED TO ACCOMPLISH ALL TESTS, ETC. B. APPROVED HYDRAULIC CALCULATIONS PRIOR TO COMMENCING WORK. C.DENSITY AS REQUIRED FOR THE INSTALLATION AND IN ACCORDANCE WITH ACCEPTED DESIGN STANDARDS. D. ISO APPROVAL PRIOR TO COMMENCING WORK. E. TESTING AND TEST CONNECTIONS. F. COMPLIANCE WITH ALL DRAWINGS AND SPECIFICATIONS. G.PERMITS AND BUILDING DEPARTMENT FILINGS. H.WRENCHES: FURNISH TWO (2) SPANNER WRENCHES FOR EACH TYPE AND SIZE OF VALVE CONNECTION AND FIRE HOSE COUPLING. 5. LAYOUT OF SPRINKLERS SHALL BE IN CAREFUL COORDINATION OF THE DRAWINGS, DETERMINING PROPER ELEVATIONS, LOCATIONS, ETC. COORDINATE WITH OTHER WORK, INCLUDING INTERFACE WITH LANDLORD'S MAINS, ETC. 6. SPRINKLER SUBCONTRACTOR SHALL COMPLY WITH THE LATEST NFPA, STATE UNIFORM FIRE PREVENTION AND BUILDING CODES AS REQUIRED. 7. SPRINKLER SUBCONTRACTOR SHALL HAVE A MINIMUM OF FIVE (5) YEARS EXPERIENCE IN THE INSTALLATION OF FIRE SPRINKLER SYSTEMS. 8. DELIVER THREE (3) SETS OF APPROVED SPRINKLER DRAWINGS TO TENANT. 9. COORDINATE WITH SPRINKLER COMPANY FOR SUBMISSION OF A TEST REPORT TO THE LOCAL FIRE AGENCY STATING THAT SYSTEM IS IN GOOD WORKING ORDER AND IS OPERATIONAL. TEMPERATURE CONTROL WORK 1. THE GC WILL FURNISH A LIGHTSTAT THERMOSTAT FOR CONTROL OF ALL NEW A.C. UNITS (MODEL #TME -POI). 2. TEMPERATURE CONTROLS SHALL BE A PART OF THE MECHANICAL WORK. FURNISH AND INSTALL ALL COMPONENTS, INCLUDING THERMOSTATS, TIME CLOCK, ELECTRIC WIRING, ETC., REQUIRED FOR A COMPLETE SYSTEM. 3. ALL CONTROL WIRING SHALL BE INSTALLED IN CONDUIT. 4. FURNISH AND INSTALL APPROPRIATE CONTROL OR ENSURE IT EXISTS FROM THE MANUFACTURER FOR FRESH AIR AND RETURN AIR DAMPERS TO EACH UNIT AS REQUIRED FOR PROPER BALANCING. COORDINATE WITH EQUIPMENT SUPPLIER. 5. FURNISH AND INSTALL A SEVEN DAY TIME CLOCK, WHICH SHALL SET THE SYSTEM ON "DAY' OR "NIGHT" CYCLE. 6. ON DAY CYCLE: A. SUPPLY FAN RUNS CONTINUOUSLY. B. ON A RISE IN SPACE TEMPERATURE AND CALL FOR COOLING IN THE AREA, THE COOLING CYCLE SHALL BE ENERGIZED AND CONTINUE TO OPERATE UNTIL THE THERMOSTAT IS SATISFIED. C.ON A FALL IN SPACE TEMPERATURE AND CALL FOR HEATING IN THE AREA, THE HEATING CYCLE SHALL BE ENERGIZED AND CONTINUE TO OPERATE UNTIL THE THERMOSTAT IS SATISFIED. 7. ON NIGHT CYCLE: A. SUPPLY FAN OFF. B. FRESH AIR DAMPER CLOSED. C.COOLING CYCLE INOPERATIVE. D. ON A FALL IN SPACE TEMPERATURE AND CALL FOR HEATING IN THE AREA, THE HEATING CYCLE SHALL BE ENERGIZED AND CONTINUE TO OPERATE UNTIL THE THERMOSTAT IS SATISFIED. 8. CONTROLS SHALL BE INSTALLED COMPLETE AS A SUBCONTRACT TO THE MECHANICAL CONTRACT BY A CONTRACTOR SPECIALIZING IN TEMPERATURE CONTROLS. INSTALLATION BY ANYONE OTHER THAN A CONTROL SUBCONTRACTOR WILL NOT BE PERMITTED. 9. FURNISH AND INSTALL A SMOKE DETECTOR IN THE RETURN AIR DUCT AT THE NEW A.C. UNITS THAT WILL SHUT THE UNIT DOWN WHEN SMOKE IS SENSED. MECHANICAL WORK NOTES - AIR FILTERS 1. ON THE DAY OF STORE CONSTRUCTION COMPLETION/TURNOVER, THE AIR CONDITIONING EQUIPMENT FILTERS, IF ANY, (WHETHER NEW CONSTRUCTION OR EXISTING) SHALL BE REPLACED WITH NEW FILTERS. MECHANICAL WORK NOTES - GENERAL 1. MECHANICAL WORK SHALL BE COMPLETE IN EVERY DETAIL AND ALL MISCELLANEOUS ITEMS OF MATERIAL AND LABOR NECESSARY TO COMPLETE THE WORK DESCRIBED, SHOWN OR REASONABLY IMPLIED ON DRAWINGS OR SPECIFICATIONS SHALL BE INCLUDED IN THE CONTRACT. CONTRACTOR SHALL MAKE MINOR ADJUSTMENTS TO THE WORK WHERE REQUESTED BY THE TENANT, WHEN SUCH ADJUSTMENTS ARE NECESSARY TO PROPER OPERATION AND WITHIN THE INTENT OF THE CONTRACT. 2. MECHANICAL CONTRACTOR SHALL VISIT THE SITE AND VIEW ALL EXISTING CONDITIONS BEFORE SUBMITTING A PROPOSAL FOR THE WORK AS DESCRIBED AND SHOWN. NO EXTRAS WILL BE ENTERTAINED FOR FAILURE TO MAKE THIS VISIT. 3. MECHANICAL CONTRACTOR SHALL ACCEPT SOLE AND COMPLETE RESPONSIBILITY FOR CONDITIONS OF THE JOB SITE, INCLUDING SAFETY OF ALL PERSONS AND PROPERTY DURING PERFORMANCE OF THE WORK. 4. CONFORM TO GENERAL CONTRACTOR'S SCHEDULE AND INSTRUCTIONS THROUGHOUT THE DURATION OF THE PROJECT AS REQUIRED TO COMPLY IN EVERY WAY NECESSARY. 5. CONTRACTOR SHALL NOTIFY THE ARCHITECT AND /OR ENGINEER OF ERRORS, OMISSIONS OR DISCREPENCIES BEFORE CONSTRUCTION OR FABRICATION OF AFFECTED WORK, OR, FAILING SUCH NOTICE, SHALL BE RESPONSIBLE FOR CORRECTING SAME WITHOUT COST TO TENANT, ARCHITECT OR ENGINEER. 6. ORDER EQUIPMENT ON A TIMELY BASIS (WITHIN 5 DAYS OF RECEIPT OF CONTRACT) TO MAINTAIN CONSTRUCTION SCHEDULE. 7. SUBMIT FIVE (5) COPIES OF SHOP DRAWINGS OF ALL EQUIPMENT FOR REVIEW BY THE ENGINEER /ARCHITECT. ONE (1) COPIES WILL BE RETAINED FOR RECORD. ONLY FURNISH SYSTEMS, EQUIPMENT AND MATERIAL IN COMPLIANCE WITH APPROVED SHOP DRAWINGS. 8. WORK SHALL INCLUDE STARTUP OF ALL SYSTEMS, FURNISHING OF OPERATING AND MAINTENANCE INSTRUCTIONS, WARRANTEE FOR ALL EQUIPMENT AND ONE YEAR GUARANTEE OF ALL WORKMANSHIP, COMMENCING ON DATE OF ACCEPTANCE BY THE TENANT. 9. WORK SHALL ALSO INCLUDE FULL ONE (1) YEAR MAINTENANCE, PARTS AND SERVICE CONTRACT FOR ALL EQUIPMENT FURNISHED UNDER THE CONTRACT. 10.ON ALL AIR CONDITIONING EQUIPMENT WHICH INCLUDES COMPRESSORS (ROOFTOP, SPLIT SYSTEMS, ETC.), INCLUDE AN EXTENDED FOUR (4) YEAR WARRANTY FOR THE COMPRESSOR. 11.VOLUME DAMPERS, SPLITTERS AND DEFLECTORS SHALL BE INSTALLED IN ALL DUCTS TO PERMIT ACCURATE BALANCING OF SYSTEM. THE DAMPERS, SPLITTERS AND DEFLECTORS SHALL BE ADJUSTED TO SATISFY THE HVAC REQUIREMENTS OF THE CONDITIONED SPACE AND LOCKED IN PLACE AS REQUIRED. 12.WORK SHALL ALSO INCLUDE TESTING AND BALANCING OF A.C. SYSTEM BY A CERTIFIED BALANCING CONTRACTOR. CONTRACTOR SHALL SUBMIT COPIES OF TEST AND BALANCE REPORTS SHOWING DETAILED RESULTS OF WORK, INCLUDING, BUT NOT LIMITED TO THE FOLLOWING: FLOW READINGS, STATIC PRESSURES, TEMPERATURE READINGS, MOTOR AMPERAGE, BALANCING OF AIR QUANTITIES TO PLAN REQUIREMENTS, ETC. AS REQUIRED. MAKE ALL ADJUSTMENTS AS REQUIRED TO PROVIDE DESIGN AIR FLOW. 13.FURNISH ALL EQUIPMENT MANUALS AND WARRANTIES TO TENANT AT THE COMPLETION OF THE PROJECT. 14.WHERE APPUCABLE, FURNISH AND INSTALL VIBRATION ISOLATION AS REQUIRED TO REDUCE, LIMIT OR REMOVE ALL VIBRATIONS FOR ALL MOVING EQUIPMENT. VIBRATION ISOLATION SHALL BE IN ACCORDANCE WITH ASHRAE RECOMMENDATIONS. 15.PROVIDE ENGRAVED BAKELITE NAMEPLATES FOR ALL MECHANICAL EQUIPMENT INCLUDING TENANT'S NAME AND SPACE NUMBER. LETTERS SHALL BE 2" HIGH OR AS REQUIRED BY THE LANDLORD. 16.ALL FABRICATED COMPONENTS (CONTRACTOR OR MANUFACTURER) OF THE OUTSIDE AIR, SUPPLY AIR, RETURN AIR AND EXHAUST AIR SYSTEMS SHALL BE CONSTRUCTED AND INSTALLED AIR TIGHT. THE INSTALLED SYSTEMS SHALL BE PRESSURE TESTED AS REQUIRED. 17.NOT USED. 18.FURNISH TWO (2) COPIES OF AS BUILT DRAWINGS OF THE A.C. SYSTEM TO THE OWNER FOR REVIEW AND APPROVAL, OR SUBMIT A LETTER TO THE OWNER CONFIRMING THAT THE SYSTEM WAS INSTALLED AS PER PLANS AND SPECIFICATIONS. 19.ALL WORK AND EQUIPMENT SHALL BE CLEANED TO THE SATISFACTION OF THE OWNER BEFORE TURNING PROJECT OVER TO THE OWNER. 20.SEAL ALL PENETRATIONS THROUGH WALLS, CEILINGS, FLOORS, ETC. SO THAT THEY ARE AIR, WATER AND FIRE TIGHT. 21.FURNISH AND INSTALL ACCESS PANELS FOR ALL CONCEALED EQUIPMENT, FIRE DAMPERS, PIPING VALVES, CLEANOUTS, ETC. ACCESS PANELS SHALL BE OF SUFFICIENT SIZE TO PROVIDE ADEQUATE WORKING CLEARANCE AND ACCESS. 22.FURNISH ALL MATERIAL AND EQUIPMENT AS SPECIFIED, EXCEPT WHERE SPECIFIC APPROVAL FOR SUBSTITUTION IS GIVEN BY THE TENANT. 23.PROPOSAL SHALL BE BASED ON SPECIFIED MATERIAL AND EQUIPMENT. IN ORDER TO PROMOTE COMPETITION, HOWEVER, BIDDERS ARE ENCOURAGED TO SUBMIT ALTERNATE PROPOSALS ON ANY ALTERNATE MATERIALS AND /OR EQUIPMENT THEY WISH TO PROPOSE, INCLUDING ANY PRICE CHANGES EFFECTED BY ACCEPTANCE OF ALTERNATES. 24.COST OF ANY CHANGES REQUIRED BY OTHER TRADES DUE TO SUBSTITUTION OF ALTERNATE EQUIPMENT SHALL BE INCLUDED IN THE ALTERNATE PROPOSAL. 25.ALTERNATE PROPOSALS WILL BE ACCEPTED OR REJECTED BEFORE ISSUANCE OF CONTRACTS. NO CHANGES WILL BE ALLOWED AFTER THE CONTRACT IS SIGNED. ANY UNAUTHORIZED CHANGES TO THE DESIGN AND LAYOUT MAY BE REQUIRED TO BE REMOVED AT CONTRACTOR'S EXPENSE IF DEEMED NECESSARY BY THE ARCHITECT, ENGINEER OR OWNER'S REPRESENTATIVE. 26.VERIFY LOCAL CONDITIONS AT SITE. 27.COMPLY WITH ALL APPUCABLE CODES. 28.SECURE AND PAY FOR ALL REQUIRED PERMITS. 29.SEE REFLECTED CEILING PLAN FOR EXACT LOCATION OF CEILING GRID, LIGHT FIXTURES, ETC. 30.ALL INSULATION MATERIALS, INCLUDING, BUT NOT LIMITED TOO DUCT INSULATION AND PIPING INSULATION SHALL HAVE A FLAME SPREAD RATING OF 25 OR LESS (ON THE FLAME SPREAD TEST SCALE) AND SMOKE DEVELOPMENT OF 50 OR LESS (ON THE SMOKE TEST SCALE) OR AS DEFINED BY NFPA 255 STANDARD METHOD OF TESTING OF SURFACE BURNING CHARACTERISTICS OF BUILDING MATERIALS, LOCAL CODES AND LOCAL AUTHORITIES HAVING JURISDICTION. 31.DIELECTRIC UNIONS SHALL BE USED TO CONNECT DISSIMIUAR METALS OR METAL PIPING SHALL HAVE METAL CONNECTIONS ON EACH END THREADED TO MATCH THE ADJACENT PIPING. METAL COMPONENTS SHALL BE SEPARATED BY A NYLON INSULATOR TO PREVENT CURRENT FLOW BETWEEN DISSIMILAR METALS. UNIONS SHALL BE SUITABLE FOR THE SYSTEM OPERATING PRESSURES AND TEMPERATURE WELD TYPE: ASTM A -234. RECEIVED CITY OF TUKWILA DEC 2 2 2009 PERMIT CENTER DATE: 1V•/09 JOB NO: m9 - 066 DRAWN: STAR CHECKED: DP Nig imgg - o 4-0 L co V STORE NUMBER #TBD REVISIONS W- ISSUE /\ LANDLORD WORK UNDER LANDLORD PERMIT PATE 12/6/09 '16' -ISSUE DATE 'C' -ISSUE DATE SHEET TITLE In 0 C co .12 0 MECHANICAL SPECIFICATIONS SCALE 1/4' =1' - 0' SHEET NUMBER M2.0 1/2" CW 11% CW 1/2" HW EXPANSION TANK CW ., /CW 1/27 HW 1/2" CW 1/2" HW - NEW 6 GALLON WATER HEATER ON WALL ABOVE MOP SINK COLD WATER PIPING TO SPACE BY LANDLORD NEW COLD WATER PIPING IN SPACE CAPPED BY LANDLORD - CONNECT NEW PIPING TO TOILET ROOMS IN SPACE AS REQUIRED NEW COLD WATER PIPING IN SPACE CAPPED BY LANDLORD - CONNECT NEW PIPING TO TOILET ROOMS IN SPACE AS REQUIRED ALL PLUMBING IS BY THE LANDLORD AND IS SHOWN FOR INFORMATION ONLY PART PLANS - PLUMBING WORK SCALE va - ra 3/4" EXPANSION TANK ALL PLUMBING IS BY THE LANDLORD AND IS SHOWN FOR INFORMATION ONLY 1/2" MOP SINK WATER PIPING DIAGRAM NOT TO SCALE DRAIN PAN RELIEF VALVE WATER HEATER ON WALL ABOVE MOP SINK 1" DRAIN DOWN TO MOP SINK WITH APPROVED AIR GAP NEW 4" SANITARY PIPE CAPED IN SPACE - CONNECT NEW PIPE AS REQUIRED. NEW 4" SANITARY PIPE TO SPACE BY LANDLORD NEW 4" VTR THROUGH FLOOR (TYPICAL) W.C. J " " ALL PLUMBING IS BY THE LANDLORD AND IS SHOWN FOR INFORMATION ONLY 1 1/2" NEW 4" SANITARY PIPE TO SPACE BY LANDLORD -0 " 1 1/2" " MOP SINK PLUMBING EQUIPMENT AND MATERIAL LAVATORIES: AMERICAN STANDARD #0124.024 "COMRADE', 20" X 18", WITH #2385.049 FAUCET, SUPPUES, STOPS, DRAIN, P_TRAP AND WALL HANGER. WATER CLOSETS: TOTO #CST744SL -ADA "DRAKE", 16.5" HIGH, FLOOR MOUNTED, 1.6 GPM FLUSH, WITH SUPPLY, STOP AND WHITE OPEN FRONT SEAT, LESS COVER. MOP SINK: MUSTEE #63M, FLOOR MOUNTED, 24" X 24 ", COMPLETE WITH INTEGRAL 3" BRASS DRAIN, STAINLESS STEEL DOME WITH STRAINER AND SCREWS AND #8344.112 AMERICAN STANDARD FAUCET WITH TOP BRACE, STOPS AND VACUUM BREAKER. BOTTLE WATER COOLER: GE #GXCF25HBS, 5 GALLON BOTTLE OR EQUAL WATER HEATER: STATE #LDE- 6 -10MS, ELECTRIC, 16 GPH 0 100o RISE, 6 GALLON STORAGE, 1,650 WATTS, 120 VOLT, 1 PH, 60 HZ. EXPANSION TANK: STATE, MODEL ETC -2X, COMPLETE WITH TANK FITTING AS REQUIRED. PIPING MATERIALS: DOMESTIC WATER: TYPE L HARD TEMPER COPPER WITH WROUGHT SWEAT FITTINGS. WASTE & VENT: STANDARD WEIGHT CAST IRON WITH HUB AND SPIGOT FITTINGS. PIPE INSULATION: DOMESTIC WATER: 1" THICK, 3/4 LB. DENSITY FIBERGLASS WITH VAPOR BARRIER JACKET. PLUMBING WORK NOTES 1. ENTIRE INSTALLATION SHALL BE MADE IN STRICT ACCORDANCE WITH LANDLORD'S REQUIREMENTS. 2. THE SPACE IS NEW AND HAS NOT PREVIOUSLY BEEN OCCUPIED. REMOVE ALL EQUIPMENT, PIPING, ETC., IN THE SPACE PRESENTLY AND NOT REQUIRED FOR THE NEW INSTALLATION. 3. TWO (2) NEW TOILET ROOMS SHALL BE CONSTRUCTED. FURNISH AND INSTALL NEW PLUMBING FIXTURES, INCLUDING LAVATORIES, WATER CLOSETS, FLOOR DRAINS, ETC., IN THE LOCATIONS SHOWN. CONNECT WATER AND WASTE PIPING TO EXISTING LANDLORD PROVIDED PIPING IN SPACE AND EXTEND TO NEW FIXTURE LOCATIONS. EXTEND NEW VENT PIPE UP THROUGH ROOF. VERIFY EXACT LOCATION OF ALL STUBS AND LENGTH OF NEW PIPING REQUIRED IN FIELD PRIOR TO BID. BASE BID SHALL INCLUDE ALL PIPING NECESSARY FOR A COMPLETE INSTALLATION AND CONNECTION TO ALL PROVIDED STUBS. 4. FURNISH AND INSTALL NEW WATER HEATER THAT WILL BE MOUNTED ON THE WALL ABOVE THE MOP SINK IN ACCORDANCE WITH THE DETAIL ON THE DRAWING - WATER HEATER SHALL NOT BE MOUNTED OR SUPPORTED BY DEMISING WALL, THIS WILL NOT BE ACCEPTED. NEW WATER HEATER SHALL BE MOUNTED IN A GALVANIZED DRAIN PAN, 6" DEEP. PRESSURE/TEMPERATURE REUEF VALVE AND THE DRAIN PAN SHALL BE PIPED TO THE MOP SINK WITH APPROVED AIR GAP AS REQUIRED. 5. CUT AND PATCH THE FLOOR TO INSTALL NEW WASTE PIPING, AS REQUIRED. " NEW 4" SANITARY PIPE CAPED IN SPACE - CONNECT NEW PIPE AS REQUIRED. CO WASTE AND VENT PIPING DIAGRAM NOT TO SCALE PLUMBING WORK NOTES - GENERAL 1L LANDLORD WORK UNDER LANDLORD PERMIT REMOVED FLOOR DRAINS AND CORRECTED WATER HEATER INSTALLATION NOTES /SCOPE 1. PLUMBING WORK SHALL BE COMPLETE IN EVERY DETAIL AND ALL MISCELLANEOUS ITEMS OF MATERIAL AND LABOR NECESSARY TO COMPLETE THE WORK DESCRIBED, SHOWN OR REASONABLY IMPLIED ON DRAWINGS OR SPECIFICATIONS SHALL BE INCLUDED IN THE CONTRACT. CONTRACTOR SHALL MAKE MINOR ADJUSTMENTS TO THE WORK WHERE REQUESTED BY THE TENANT, WHEN SUCH ADJUSTMENTS ARE NECESSARY TO PROPER OPERATION AND WITHIN THE INTENT OF THE CONTRACT. 2. PLUMBING CONTRACTOR SHALL VISIT THE SITE AND VIEW ALL EXISTING CONDITIONS BEFORE SUBMITTING A PROPOSAL FOR THE WORK AS DESCRIBED AND SHOWN. NO EXTRAS WILL BE ENTERTAINED FOR FAILURE TO MAKE THIS VISIT. 3. PLUMBING CONTRACTOR SHALL ACCEPT SOLE AND COMPLETE RESPONSIBILITY FOR CONDITIONS OF THE JOB SITE, INCLUDING SAFETY OF ALL PERSONS AND PROPERTY DURING PERFORMANCE OF THE WORK. 4. CONFORM TO GENERAL CONTRACTOR'S SCHEDULE AND INSTRUCTIONS THROUGHOUT THE DURATION OF THE PROJECT AS REQUIRED TO COMPLY IN EVERY WAY NECESSARY. 5. CONTRACTOR SHALL NOTIFY THE ARCHITECT AND /OR ENGINEER OF ERRORS, OMMISSIONS OR DISCREPENCIES BEFORE CONSTRUCTION OR FABRICATION OF AFFECTED WORK, OR, FAIUNG SUCH NOTICE, SHALL BE RESPONSIBLE FOR CORRECTING SAME WITHOUT COST TO TENANT, ARCHITECT OR ENGINEER. 6. ORDER EQUIPMENT ON A TIMELY BASIS (WITHIN 5 DAYS OF RECEIPT OF CONTRACT) TO MAINTAIN CONSTRUCTION SCHEDULE. 7. SUBMIT FIVE (5) COPIES OF SHOP DRAWINGS OF ALL EQUIPMENT FOR REVIEW BY THE ENGINEER /ARCHITECT. ONE (1) COPIES WILL BE RETAINED FOR RECORD. ONLY FURNISH SYSTEMS, EQUIPMENT AND MATERIAL IN COMPLIANCE WITH APPROVED SHOP DRAWINGS. 8. WORK SHALL INCLUDE STARTUP OF ALL SYSTEMS, FURNISHING OF OPERATING AND MAINTENANCE INSTRUCTIONS, WARRANTEE FOR ALL EQUIPMENT AND ONE YEAR GUARANTEE OF ALL WORKMANSHIP, COMMENCING ON DATE OF ACCEPTANCE BY THE TENANT. 9. WORK SHALL ALSO INCLUDE FULL ONE (1) YEAR MAINTENANCE, PARTS AND SERVICE CONTRACT FOR ALL EQUIPMENT FURNISHED UNDER THE CONTRACT. 10.FURNISH ALL EQUIPMENT MANUALS AND WARRANTIES TO TENANT AT THE COMPLETION OF THE PROJECT. 11.WHERE APPLICABLE, FURNISH AND INSTALL VIBRATION ISOLATION AS REQUIRED TO REDUCE, UM IT OR REMOVE ALL VIBRATIONS FOR ALL MOVING EQUIPMENT. VIBRATION ISOLATION SHALL BE IN ACCORDANCE WITH ASHRAE RECOMMENDATIONS. 12.ALL WORK AND EQUIPMENT SHALL BE CLEANED TO THE SATISFACTION OF THE OWNER BEFORE TURNING PROJECT OVER TO THE OWNER. 13.SEAL ALL PENETRATIONS THROUGH WALLS, CEILINGS, FLOORS, ETC. SO THAT THEY ARE AIR, WATER AND FIRE TIGHT. 14.FURNISH AND INSTALL ACCESS PANELS FOR ALL CONCEALED EQUIPMENT, FIRE DAMPERS, PIPING VALVES, CLEANOUTS, ETC. ACCESS PANELS SHALL BE OF SUFFICIENT SIZE TO PROVIDE ADEQUATE WORKING CLEARANCE AND ACCESS. 15.PROVIDE SHUT OFF VALVES IN THE SUPPLY PIPING TO EACH FIXTURE. FURNISH AND INSTALL AN ACCESSIBLE SERVICE VALVE ON ALL BRANCH PIPING. 16.FURNISH AND INSTALL CHAMBER SHOCK ABSORBERS AS SHOWN TO PREVENT NOISE AND DAMAGE DUE TO WATER HAMMER. 17.FURNISH AND INSTALL PRESSURE REGULATOR ON THE INCOMING WATER SERVICE IF SERVICE PRESSURE EXCEEDS 80 PSI. EXPANSION TANK (AMTROL MODEL AST -5 COMPLETE WITH ALL FITTINGS FOR A COMPLETE INSTALLATION) GATE VALVE (TYPICAL) CW 3/4" 3/4" T & P RELIEF VALVE VACUUM BREAKER III i- 3 REFER TO ARCHITECTURAL DRAWINGS SHEET A4.1 DETAIL 8 FOR INSTALLATION SPECIFICS, ETC. 18.FURNISH AND INSTALL ALL PIPE HANGERS, CARRIERS, SADDLES, AND SUPPPOTS TO PROPERLY SUPPORT AND PROTECT ALL PIPING IN THE SPACE AS REQUIRED. HANGERS FOR HORIZONTAL PIPING WHERE PIPING IS TO BE INSULATED BE LARGE ENOUGH TO PASS INSULATION AND SHALL BE ELCEN FIG. 12 CLEVIS TYPE, WITH MEANS FOR VERTICAL ADJUSTMENT. INSTALL HANGERS AS FOLLOWS: PIPE SIZE HANGER ROD SIZE MAXIMUM SPACING 1/2" TO 1" 3/8" 8' -0" O.C. 1 -1/4" TO 2" 3/8" 10' -0" O.C. 2-1/2" AND ABOVE 1/2" 10' -0" O.C. 19.VERIFY LOCATION, DEPTH AND SIZE OF EXISTING SANITARY SEWER AT SITE. CONNECT AS REQUIRED. SEWER SHALL BE INSTALLED WITH 1/4" PITCH PER FOOT AND OUTSIDE SEWER SHALL BE INSTALLED WITH MINIMUM OF 3' -0" COVER. 20.FURNISH ALL EQUIPMENT MANUALS AND WARRANTIES TO TENANT AT THE COMPLETION OF THE PROJECT. 21.ALL WORK AND EQUIPMENT SHALL BE CLEANED TO THE SATISFACTION OF THE OWNER BEFORE TURNING PROJECT OVER TO THE OWNER. 22.FURNISH AND INSTALL TRAP PRIMERS ON ALL FLOOR DRAINS. 23.FURNISH ALL MATERIAL AND EQUIPMENT AS SPECIFIED, EXCEPT WHERE SPECIFIC APPROVAL FOR SUBSTITUTION IS GIVEN BY THE TENANT. 24.PROPOSAL SHALL BE BASED ON SPECIFIED MATERIAL AND EQUIPMENT. IN ORDER TO PROMOTE COMPETITION, HOWEVER, BIDDERS ARE ENCOURAGED TO SUBMIT ALTERNATE PROPOSALS ON ANY ALTERNATE MATERIALS AND /OR EQUIPMENT THEY WISH TO PROPOSE, INCLUDING ANY PRICE CHANGES EFFECTED BY ACCEPTANCE OF ALTERNATES. 25.COST OF ANY CHANGES REQUIRED BY OTHER TRADES DUE TO SUBSTITUTION OF ALTERNATE EQUIPMENT SHALL BE INCLUDED IN THE ALTERNATE PROPOSAL 26.ALTERNATE PROPOSALS WILL BE ACCEPTED OR REJECTED BEFORE ISSUANCE OF CONTRACTS. NO CHANGES WILL BE ALLOWED AFTER THE CONTRACT IS SIGNED. ANY UNAUTHORIZED CHANGES TO THE DESIGN AND LAYOUT MAY BE REQUIRED TO BE REMOVED AT CONTRACTOR'S EXPENSE IF DEEMED NECESSARY BY THE ARCHITECT, ENGINEER OR OWNER'S REPRESENTATIVE. 27.VERIFY LOCAL CONDITIONS AT SITE. 28.COMPLY WITH ALL APPLICABLE CODES. 29.SECURE AND PAY FOR ALL REQUIRED PERMITS. 30.SEE REFLECTED CEILING PLAN FOR EXACT LOCATION OF CEIUNG GRID, LIGHT FIXTURES, ETC. 31.ALL INSULATION MATERIALS, INCLUDING, BUT NOT UMITED TOO DUCT INSULATION AND PIPING INSULATION SHALL HAVE A FLAME SPREAD RATING OF 25 OR LESS (ON THE FLAME SPREAD TEST SCALE) AND SMOKE DEVELOPMENT OF 50 OR LESS (ON THE SMOKE TEST SCALE) OR AS DEFINED BY NFPA 255 STANDARD METHOD OF TESTING OF SURFACE BURNING CHARACTERISTICS OF BUILDING MATERIALS, LOCAL CODES AND LOCAL AUTHORITIES HAVING JURISDICTION. 32.DIELECTRIC UNIONS SHALL BE USED TO CONNECT DISSIMIUAR METALS OR METAL PIPING SHALL HAVE METAL CONNECTIONS ON EACH END THREADED TO MATCH THE ADJACENT PIPING. METAL COMPONENTS SHALL BE SEPARATED BY A NYLON INSULATOR TO PREVENT CURRENT FLOW BETWEEN DISSIMILAR METALS. UNIONS SHALL BE SUITABLE FOR THE SYSTEM OPERATING PRESSURES AND TEMPERATURE WELD TYPE: ASTM A -234. a HW - N - UNION (TYP.) WATER HEATER 2" WIDE 20 GA SHEET METAL BAND, SECURE TO WALL FOR SEISMIC BRACING WHERE REQUIRED BY CODE GALV. DRIP PAN 1" DRAIN TO FLOOR DRAIN WITH APPROVED AIR GAP WATER HEATER PIPING DETAIL NOT TO SCALE b 2 ci RECEIVED CITY OF TUKWILA DEC 2 2 2009 PERMIT CENTER DATE: 11M/09 JOB NO: 09 DRAWN: STAFF CHECKED: PP s Q o NZ W � CC cc �Z� cc W wi<4 K LO cci C ON F- f11 a) :mg 4 .1/ co .1 V %TBD REVISIONS 'A' -ISSUE 0 LANDLORD WORK UNDER LANDLORD PERMIT PATE 12/6/09 'S' -ISSUE DATE 'G' -ISSUE DATE SHEET TITLE FLOOR PLAN PLUMBING WORK SCALE 1/4' -1' - O" SHEET NUMBER P1.0