Loading...
HomeMy WebLinkAboutPermit D09-270 - EWC GROUP - TENANT IMPROVEMENTEWC GROUP 4i0 ANDOVER PK E D09 -270 City dkukwila Parcel No.: 0223400071 Permit Number: D09 -270 Address: 410 ANDOVER PK E TUKW Issue Date: 01/11/2010 Suite No: Permit Expires On: 01/05/2011 Tenant: Name: EWC GROUP Address: 410 ANDOVER PK E , TUKWILA WA Owner: Name: R2R INVESTMENTS LLC Address: 7979 S 180TH ST , KENT WA 98032 Phone: Contact Person: Name: FRED BARBER Address: 7979 S 180 ST , KENT WA 98032 Phone: 206 - 310 -9007 Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone : 206-431-3670 Fax: 206 - 431 -3665 Web site: http://wriiwci.tukwila.wa.us Contractor: Name: OWNER AFFIDAVIT - FRED BARBER Address: Phone: Contractor License No: DEVELOPMENT PERMIT DESCRIPTION OF WORK: PREVIOUS PERMIT ISSUED FOR HANDICAPPING EXISTING BATHROOM, REMOVING OFFICE WALL, PAINT HANDICAPPED PARKING AND EMERGENCY EXIT LIGHTING. PERMIT D08 -259. REPLACE WOODEN FORKLIFT RAMP WITH ASPHALT RAMP REVISION #1 TO ADD EMERGENCY LIGHTING, PATH OF EGRESS, AND NEW SOUTH DOOR ALONG WITH A STAIR LANDING AND STAIRS. Value of Construction: $6,000.00 Fees Collected: $502.62 Type of Fire Protection: SPRINKLERS /AFA International Building Code Edition: 2006 Type of Construction: Occupancy per IBC: 0024 doc: IBC -7/07 * *continued on next page ** • Expiration Date: D09 -270 Printed: 12 -28 -2010 Public Works Activities: Channelization / Striping: N Curb Cut / Access / Sidewalk / CSS: N doc: IBC -7/07 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Inspection Request Line: 206- 431 -2451 Web site: http: / /www.ci.tukwila.wa.us r Fire Loop Hydrant: N Number: 0 Size (Inches): 0 Flood Control Zone: Hauling: N Start Time: End Time: Land Altering: Volumes: Cut 0 c.y. Fill 0 c.y. Landscape Irrigation: Moving Oversize Load: Start Time: End Time: Sanitary Side Sewer: Sewer Main Extension: Private: Public: Storm Drainage: Street Use: Profit: N Non - Profit: N Water Main Extension: Private: Public: Water Meter: N Permit Number: DO9 -270 Issue Date: 01/11/2010 Permit Expires On: 01/05/2011 Permit Center Authorized Signature: I Date: )-" ) — , I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or,theperformance of work. I am authorized to sign and obtain this development permit. Signature: -' Date: t Z) 2 8 Print Name: f 6Zt:� (N This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. D09 -270 Printed: 12 -28 -2010 Parcel No.: Address: Suite No: Tenant: Name: Address: Owner: Name: Address: Phone: Contact Person: Name: Address: Phone: Value of Construction: Type of Fire Protection: Type of Construction: doc: IBC -10/06 0223400071 410 ANDOVER PK E TUKW Cit" 11 f Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Inspection Request Line: 206 - 431 - 2451 Web site: http: / /www.ci.tukwila.wa.us EWC GROUP 410 ANDOVER PK E , TUKWILA WA R2R INVESTMENTS LLC 7979 S 180TH ST , KENT WA 98032 FRED BARBER 7979 S 180 ST , KENT WA 98032 206 - 310 -9007 Contractor: Name: OWNER AFFIDAVIT - FRED BARBER Address: Phone: Contractor License No: DESCRIPTION OF WORK: PREVIOUS PERMIT ISSUED FOR HANDICAPPING EXISTING BATHROOM, REMOVING OFFICE WALL, PAINT HANDICAPPED PARKING AND EMERGENCY EXIT LIGHTING. PERMIT D08 -259. REPLACE WOODEN FORKLIFT RAMP WITH ASPHALT RAMP $6,000.00 SPRINKLERS /AFA DEVELOPMENT PERMIT * *continued on next page ** D09 -270 Permit Number: Issue Date: Permit Expires On: Expiration Date: Fees Collected: International Building Code Edition: Occupancy per IBC: D09 -270 01/11/2010 07 /10/2010 $322.62 2006 0024 Printed: 01 -11 -2010 Public Works Activities: Channelization / Striping: N Curb Cut / Access / Sidewalk / CSS: N City OPTukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Inspection Request Line: 206 - 431 - 2451 Web site: http: / /www.ci.tukwila.wa.us Permit Number: D09 -270 Issue Date: 01/11/2010 Permit Expires On: 07/10/2010 Fire Loop Hydrant: N Number: 0 Size (Inches): 0 Flood Control Zone: Hauling: N Start Time: End Time: Land Altering: Volumes: Cut 0 c.y. Fill 0 c.y. Landscape Irrigation: Moving Oversize Load: Start Time: End Time: Sanitary Side Sewer: Sewer Main Extension: Private: Public: Storm Drainage: Street Use: Profit: N Non - Profit: N Water Main Extension: Private: Public: Water Meter: N Permit Center Authorized Signature: I hereby certify that I have read and governing this work will be complie The granting of this permit does not pre doc: IBC -10/06 FQ D59 xami with, Date: oil l2 ed this permit and know the same to be true and correct. All provisions of law and ordinances hether specified herein or not. e to give authority to violate or cancel the provisions of any other state or local laws regulating construction performance of work. I am authorized to sign and obtain this development permit. Signature: Date: 1 l 2.310 Print Name: This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. D09 -270 Printed: 01 -11 -2010 Parcel No.: 0223400071 Address: 410 ANDOVER PK E TUKW Suite No: Tenant: EWC GROUP 1: ** *BUILDING DEPARTMENT CONDITIONS * ** • • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206- 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us PERMIT CONDITIONS Permit Number: D09 -270 Status: ISSUED Applied Date: 12/30/2009 Issue Date: 01/11/2010 2: No changes shall be made to the approved plans unless approved by the design professional in responsible charge and the Building Official. 3: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center (206/431- 3670). 4: All permits, inspection records, and approved plans shall be at the job site and available to the inspectors prior to start of any construction. These documents shall be maintained and made available until final inspection approval is granted. 5: All construction shall be done in conformance with the approved plans and the requirements of the International Building Code or International Residential Code, International Mechanical Code, Washington State Energy Code. 6: Remove all demolition rubble and loose miscellaneous material from lot or parcel of ground, properly cap the sanitary sewer connections, and properly fill or otherwise protect all basements, cellars, septic tanks, wells, and other excavations. Final inspection approval will be determined by the building inspector based on satisfactory completion of this requirement. 7: There shall be no occupancy of a building until final inspection has been completed and approved by Tukwila building inspector. No exception. 8: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206- 431 - 3670). 9: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206- 431 - 3670). 10: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. 11: The total number of fire extinguishers required for an ordinary hazard occupancy with Class A fire hazards is calculated at one extinguisher for each 1,500 sq. ft. of area. The extinguisher(s) should be of the "All Purpose" (2A, 20B:C) dry chemical type. Travel distance to any fire extinguisher must be 75' or less. (IFC 906.3) (NFPA 10, 3 -2.1) 12: Portable fire extinguishers, not housed in cabinets, shall be installed on the hangers or brackets supplied. Hangers or brackets shall be securely anchored to the mounting surface in accordance with the manufacturer's installation instructions. Portable fire extinguishers having a gross weight not exceeding 40 pounds (18 kg) shall be installed so that its top is not more than 5 feet (1524 mm) above the floor. Hand -held portable fire extinguishers having a gross weight exceeding 40 pounds (18 kg) shall be installed so that its top is not more than 3.5 feet (1067 mm) above the floor. The clearance between the floor and the bottom of the installed hand -held extinguishers shall not be less than 4 inches (102 mm). (IFC 906.7 and IFC 906.9) doc: Cond -10/06 D09 -270 Printed: 12 -28 -2010 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us 13: Fire extinguishers shall not be obstructed or obscured from view. In rooms or areas in which visual obstruction cannot be completely avoided, means shall be provided to indicate the locations of the extinguishers. (IFC 906.6) 14: Extinguishers shall be located in conspicuous locations where they will be readily accessible and immediately available for use. These locations shall be along normal paths of travel, unless the fire code official determines that the hazard posed indicates the need for placement away from normal paths of travel. (IFC 906.5) 15: Fire extinguishers require monthly and yearly inspections. They must have a tag or label securely attached that indicates the month and year that the inspection was performed and shall identify the company or person performing the service. Every six years stored pressure extinguishers shall be emptied and subjected to the applicable recharge procedures. If the required monthly and yearly inspections of the fire extinguisher(s) are not accomplished or the inspection tag is not completed, a reputable fire extinguisher service company will be required to conduct these required surveys. (NFPA 10, 4 -3, 4 -4) 16: Egress doors shall be readily openable from the egress side without the use of a key or special knowledge or effort. (IFC 1008.1.8.3 subsection 2.2) 17: Dead bolts are not allowed on auxiliary exit doors unless the dead bolt is automatically retracted when the door handle is engaged from inside the tenant space. (IFC Chapter 10) 18: Door handles, pulls, latches, locks and other operating devices on doors required to be accessible by Chapter 11 of the International Building Code shall not require tight grasping, tight pinching or twisting of the wrist to operate. (IFC 1008.1.8.1) 19: Exit hardware and marking shall meet the requirements of the International Fire Code. (IFC Chapter 10) 20: Exits and exit access doors shall be marked by an approved exit sign readily visible from any direction of egress travel. Access to exits shall be marked by readily visible exit signs in cases where the exit or the path of egress travel is not immediately visible to the occupants. Exit sign placement shall be such that no point in an exit access corridor is more than 100 feet (30,480 mm) or the listed viewing distance for the sign, whichever is less, from the nearest visible exit sign. (IFC 1011.1) 21: Every exit sign and directional exit sign shall have plainly legible letters not less than 6 inches (152 mm) high with the principal strokes of the letters not less than 0.75 inch (19.1 mm) wide. The word "EXIT" shall have letters having a width not less than 2 inches (51 mm) wide except the letter "I", and the minimum spacing between letters shall not be less than 0.375 inch (9.5 mm). Signs larger than the minimum established in section 1011.5.1 of the International Fire Code shall have letter widths, strokes and spacing in proportion to their height. The word "EXIT" shall be in high contrast with the background and shall be clearly discernible when the exit sign illumination means is or is not energized. If an arrow is provided as part of the exit sign, the construction shall be such that the arrow direction cannot be readily changed. (IFC 1011.5.1) 22: Exit signs shall be illuminated at all times. To ensure continued illumination for a duration of not less than 90 minutes in case of primary power loss, the sign illumination means shall be connected to an emergency power system provided from storage batteries, unit equipment or on -site generator. (IFC 1006.1, 1006.2, 1006.3) 23: Emergency lighting facilities shall be arranged to provide initial illumination that is at least an average of 1 foot -candle (11 lux) and a minimum at any point of 0.1 foot -candle (1 lux) measured along the path of egress at floor level. Illumination levels shall be permitted to decline to 0.6 foot -candle (6 lux) average and a minimum at any point of 0.06 foot -candle (0.6 lux) at the end of the emergency lighting time duration. A maximum -to- minimum illumination uniformity ratio of 40 to 1 shall not be exceeded. (IFC 1006.4) 24: Aisles leading to required exits shall be provided from all portions of the building and the required width of the aisles shall be unobstructed. (IFC 1013.4) 25: Gates serving the means of egress system shall comply with the requirements of the International Fire Code. Gates used doc: Cond -10/06 D09 -270 Printed: 12 -28 -2010 doc: Cond -10/06 s City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci. tukwila.wa.us * *continued on next page ** • as a component in a means of egress shall conform to the applicable requirements for doors. (IFC 1008.2) 26: Maintain sprinkler coverage per N.F.P.A. 13. Addition/relocation of walls, closets or partitions may require relocating and/or adding sprinkler heads. (IFC 901.4) 27: Sprinklers shall be installed under fixed obstructions over 4 feet (1.2 m) wide such as ducts, decks, open grate flooring, cutting tables, shelves and overhead doors. (NFPA 13- 8.6.5.3.3) 28: All new sprinkler systems and all modifications to existing sprinkler systems shall have fire department review and approval of drawings prior to installation or modification. New sprinkler systems and all modifications to sprinkler systems involving more than 50 heads shall have the written approval of Factory Mutual or any fire protection engineer licensed by the State of Washington and approved by the Fire Marshal prior to submittal to the Tukwila Fire Prevention Bureau. No sprinkler work shall commence without approved drawings. (City Ordinance No. 2050). 29: Maintain fire alarm system audible /visual notification. Addition/relocation of walls or partitions may require relocation and/or addition of audible /visual notification devices. (City Ordinance #2051) 30: All new fire alarm systems or modifications to existing systems shall have the written approval of The Tukwila Fire Prevention Bureau. No work shall commence until a fire department permit has been obtained. (City Ordinance #2051) (IFC 104.2) 31: All electrical work and equipment shall conform strictly to the standards of the National Electrical Code. (NFPA 70) 32: The maximum flame spread class of finish materials used on interior walls and ceilings shall not exceed that set forth in Table No. 803.5 of the International Building Code. 33: This review limited to speculative tenant space only - special fire permits may be necessary depending on detailed description of intended use. 34: Any overlooked hazardous condition and/or violation of the adopted Fire or Building Codes does not imply approval of such condition or violation. 35: These plans were reviewed by Inspector 511. If you have any questions, please call Tukwila Fire Prevention Bureau at (206)575 -4407. D09 -270 Printed: 12 -28 -2010 • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Fax: 206-431-3665 Web site: http: / /www.ci.tukwila.wa.us I hereby certify that I have read these conditions and will comply with them as outlined. All provisions of law and this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provision of any other work construction or the performance of work. Signature: Print Name: Lp 2_ 0 doc: Cond-10/06 D09 -270 Date: (7_ J 8 ` 200t ordinances governing or local laws regulating Printed: 12 -28 -2010 Parcel No.: 0223400071 Address: 410 ANDOVER PK E TUKW Suite No: Tenant: EWC GROUP 1: ** *BUILDING DEPARTMENT CONDITIONS * ** a w City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http://www.ci.tukwila.wa.us PERMIT CONDITIONS Permit Number: D09 -270 Status: ISSUED Applied Date: 12/30/2009 Issue Date: 01/11/2010 2: No changes shall be made to the approved plans unless approved by the design professional in responsible charge and the Building Official. 3: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center (206/431- 3670). 4: All permits, inspection records, and approved plans shall be at the job site and available to the inspectors prior to start of any construction. These documents shall be maintained and made available until final inspection approval is granted. 5: All construction shall be done in conformance with the approved plans and the requirements of the International Building Code or International Residential Code, International Mechanical Code, Washington State Energy Code. 6: Remove all demolition rubble and loose miscellaneous material from lot or parcel of ground, properly cap the sanitary sewer connections, and properly fill or otherwise protect all basements, cellars, septic tanks, wells, and other excavations. Final inspection approval will be determined by the building inspector based on satisfactory completion of this requirement. 7: There shall be no occupancy of a building until final inspection has been completed and approved by Tukwila building inspector. No exception. 8: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the Cityof Tukwila Permit Center. 9: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206- 431 - 3670). 10: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. doc: Cond -10/06 * * continued on next page ** D09 -270 Printed: 01 -11 -2010 N City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http://www.ci.tukwila.wa.us I hereby certify that I have read these conditions and will comply with them as outlined. All provisions of law and this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provision of any other work construction or the performance of work. Signature: Print Name: F 0 64120 r > L� doc: Cond -10/06 D09 -270 Date: t 11) 7 .010 ordinances governing or local laws regulating Printed: 01 -11 -2010 SITE LOCATION Site Address: y JO AN 000E12 Pfl (21-< l: � RC)O P LAIC Property Owners Name: R2_ C k =•N STin Et'4 I S t Mailing Address: - 19 - 7 i S• I 86" S 1 1.4 ENT City Tenant Name: Name: Fr'REIN APO ER Mailing Address: - 79 - 79 S. e © H S• E -Mail Address: FRED 1 3 12 2.G L M s N• C.O M Company Name: Mailing Address: Via, CITY OF TUKWIL - Community Development Department Public Works Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www.ci.tukwila.wa.us Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. * *Please Print ** Contact Person: E -Mail Address: Contractor Registration Number: Company Name: Mailing Address: Contact Person: E -Mail Address: Company Name: Mailing Address: Contact Person: E -Mail Address: H: \Applications\Porms- Applications On Line\2009 Applications \I -2009 - Permit Application.doc Revised: 1.2009 bh Building Permit No. /()O 9 Mechanical Permit No. 2,70 Plumbing /Gas Permit No. Public Works Permit No. Project No. For office use only), King Co Assessor's Tax No.: Oa-�3'- 0 `" 001 I Suite Number: City Fax Number: New Tenant: Floor: tit) State State State Yes ❑..No Zip CONTACT PERSON - who do we contact when your permit is ready to be issued Day Telephone: (2.0G) 3 JO - gin 07 IBC F 1%1 i Ui A c 1 SO 3 Z State Zip (Li25) a 57- 353) GENERAL CONTRACTOR INFORMATION — (Contractor Information for Mechanical (pg 4) for Plumbing and Gas Piping (pg 5)) Zip City Day Telephone: Fax Number: Expiration Date: ARCHITECT OF RECORD - All plans must be wet stamped by Architect of Record Zip City Day Telephone: Fax Number: ENGINEER OF RECORD - All plans must be wet stamped by Engineer of Record State Zip City Day Telephone: Fax Number: Page 1 of 6 BUILDING PERMIT INFORIIION- 206 - 431 -3670 Valuation of Project (contractor's bid price): $ 1 O CEO. OD Existing Building Valuation: $ I l CIO C ea .00 Scope of Work (please provide detailed information): pReuro i S MT 1 1" U E n F= D " Not'Cicke.a3=4G s5TL C3RTFfRoDM f.ZFrto(J 4c oFrzr - PA -Iii 7‘ 4 a 14r c PE(2 rill D - 2.59 Will there be new rack storage? It Yes 0.. No If yes, a separate permit and plan submittal will be required. Provide All Building Areas, in Square Footage Below PLANNING DIVISION: Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) *For an Accessory dwelling, provide the following: Lot Area (sq ft): Floor area of principal dwelling: Floor area of accessory dwelling: *Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard: Compact: Handicap: Will there be a change in use? ❑ Yes ❑ No If "yes ", explain: FIRE PROTECTION /HAZARDOUS MATERIALS: Per Sprinklers Automatic Fire Alarm ❑ None ❑ Other (specify) ❑ No Safety Data Sheets. Will there be storage or use of flammable, combustible or hazardous materials in the building? Yes If "yes', attach list of materials and storage locations on a separate 8 -1/2" x 11 " paper including quantities and MaterigL SEPTIC SYSTEM Department. H: Wpplications\Forms- Applications On Line \2009 Applications \1 -2009 - Permit Application. doc Revised: 1 -2009 bh f P OPRNg :'bQ ❑ On -site Septic System — For on -site septic system, provide 2 copies of a current septic design approved by King County Health Page 2 of 6 Existing Interior Remodel Addition to Existing Structure New Type of ` Construction per IBC Type of Occupancy per IBC 1 Floor 2 Floor 3 Floor Floors thru Basement Accessory Structure* Attached Garage Detached Garage Attached Carport Detached Carport Covered Deck Uncovered Deck BUILDING PERMIT INFORIIION- 206 - 431 -3670 Valuation of Project (contractor's bid price): $ 1 O CEO. OD Existing Building Valuation: $ I l CIO C ea .00 Scope of Work (please provide detailed information): pReuro i S MT 1 1" U E n F= D " Not'Cicke.a3=4G s5TL C3RTFfRoDM f.ZFrto(J 4c oFrzr - PA -Iii 7‘ 4 a 14r c PE(2 rill D - 2.59 Will there be new rack storage? It Yes 0.. No If yes, a separate permit and plan submittal will be required. Provide All Building Areas, in Square Footage Below PLANNING DIVISION: Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) *For an Accessory dwelling, provide the following: Lot Area (sq ft): Floor area of principal dwelling: Floor area of accessory dwelling: *Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard: Compact: Handicap: Will there be a change in use? ❑ Yes ❑ No If "yes ", explain: FIRE PROTECTION /HAZARDOUS MATERIALS: Per Sprinklers Automatic Fire Alarm ❑ None ❑ Other (specify) ❑ No Safety Data Sheets. Will there be storage or use of flammable, combustible or hazardous materials in the building? Yes If "yes', attach list of materials and storage locations on a separate 8 -1/2" x 11 " paper including quantities and MaterigL SEPTIC SYSTEM Department. H: Wpplications\Forms- Applications On Line \2009 Applications \1 -2009 - Permit Application. doc Revised: 1 -2009 bh f P OPRNg :'bQ ❑ On -site Septic System — For on -site septic system, provide 2 copies of a current septic design approved by King County Health Page 2 of 6 PERMIT APPLICATION NOTES - Applicable to all permits in this application Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. Building and Mechanical Permit The Building Official may grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). Plumbing Permit The Building Official may grant one extension of time for an additional period not exceeding 180 days. The exten on shall be requested in writing and justifiable cause demonstrated. Section 103.4.3 Uniform Plumbing Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNE AUTHORIZED AGENT: Signature: �' t Print Name: f12tc. eft Ro �1Z_.. Mailing Address: `i -f `t 5 . 1 Date Application Expires: Lc 30- I v Date Application Accepted: I d.—�10.... D H:\Applications\Forms- Applications On Line12009 Applications \I -2009 - Permit Application.doc Revised: 1.2009 bh Day Telephone: City Date: 1 .7- 12ct / 200 5 (2 dc9) 31 o- ioo'7 0JA 980 State Zip Staff Initials: pi,e I Page 6 of 6 Fixture Type: YP Qty Fixt Type: YP Fi re Type: YP Qty Fixture Type: Qty Bathtub or combination bath/shower Bidet f ■thes washer, domestic Dental unit, cuspidor Dishwasher, domestic, with independent drain Drinking fountain or water cooler (per head) ood -waste grinder, t mercial Floor Drain Shower, single head trap Lavatory fountain Receptor, indirect waste Sinks Urinals Water oset Building sewer and each trailer park sewer Rain water system — per drain (inside building) Water heater and/or nt Industrial : ste treatment interceptor, luding trap and vent, exc for kitchen type grease inte ptors Each grease trap (connected to not more than 4 fixtures - <750 gallon capacity) Grease interceptor for commercial kitchen ( >750 gallon capacity) Repair or al tion of water pip', • and /or water treatmen quipment Repair or alteratir of drainage or vent pi. • Medical gas piping system serving 1 -5 inlets /outlets for a specific gas Each additional medical gas inlets /outlets greater than 5 Bac •w protective de e other than . ospheric -type vacuum eakers 2 inch (51 mm) diameter or smaller Backflow protective devi other than atmospheric -typ- vacuum breakers over 2 inch (51 mm) diameter Each lawn sprinkler system on any one meter including backflow protection devices Atmospheric -type vacuum breakers not included in lawn sprinkler backflow protections (1 -5) Atmospheric -type vacuum breakers not included in lawn sprinkler backflow protections over 5 Gas piping outlets PLUMBING AND GAS PIPING . IRMIT INFORMATION - 206 -431 -3%, , 0 PLUMBING AND GAS PIPING CONTRACTOR INFORMATION Company Name: Mailing Address: City State Zip Day Telephone: Fax Number: Expiration Date: Contact Person: E -Mail Address: Contractor Registration Number: Valuation of Project (contra .r's bid price): $ Scope of Work (please provide -tailed information): Building Use (per Int'l Building Code): Occupancy (per Int'l Building Code): Utility Purveyor: Water: Indicate type of plumbing fixtures and /or gas piping out! being install and the quantity below: H:Wpplications\Forms- Applications On- Line\2009 Applications \1-2009 Permit Application.doc Revised: 1 -2009 bh Page 5 of 6 Parcel No.: 0223400071 Address: 410 ANDOVER PK E TUKW Suite No: Applicant: EWC GROUP Receipt No.: R12 -02575 Payee: SPECIALTY WIPERS INC Payment Credit Crd VISA Authorization No. 02694G ACCOUNT ITEM LIST: Description BUILDING INVESTIGATION City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.TukwilaWA.gov TRANSACTION LIST: Type Method Descriptio Amount RECEIPT Initials: LAW Payment Date: 09/11/2012 10:28 AM User ID: 1632 Balance: $0.00 63.00 Account Code Current Pmts 000.322.800 63.00 Total: $63.00 Permit Number: D09 - 270 Status: ISSUED Applied Date: 12/30/2009 Issue Date: 01/11/2010 Payment Amount: $63.00 der: Rereint -06 Printed: 09 -11 -2012 Parcel No.: 0223400071 Address: 410 ANDOVER PK E TUKW Suite No: Applicant: EWC GROUP Receipt No.: R09 -02066 Initials: User ID: Payee: WER 1655 TRANSACTION LIST: Type Method Descriptio Amount Payment Check 1377 322.62 Authorization No. ACCOUNT ITEM LIST: Description R 2 R INVESTMENTS BUILDING - NONRES PLAN CHECK - NONRES STATE BUILDING SURCHARGE • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us Account Code Current Pmts 000.322.100 000.345.830 640.237.114 RECEIPT Total: $322.62 Permit Number: D09 -270 Status: PENDING Applied Date: 12/30/2009 Issue Date: Payment Amount: $322.62 Payment Date: 12/30/2009 09:08 AM Balance: $0.00 192.80 125.32 4.50 PAYMENT RECEIVED doc: Receiot -06 Printed: 12 -30 -2009 Parcel No.: 0223400071 Address: 410 ANDOVER PK E TUKW Suite No: Applicant: EWC GROUP Receipt No.: R10 - 02566 Initials: User ID: Payee: loc: Receiot -06 WER 1655 FRED BARBER TRANSACTION LIST: Type Method Payment Credit Crd VISA Authorization No. FINANCE I;CCOUNT ITEM LIST: Description PLAN CHECK - NONRES City of Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Fax: 206 - 431 -3665 Web site: 'http : / /www.ci.tukwila.wa.us Descriptio Amount Account Code 000.345.830 RECEIPT 180.00 Total: $180.00 Permit Number: Status: Applied Date: Issue Date: Payment Amount: $180.00 D09 -270 ISSUED 12/30/2009 01/11/2010 Payment Date: 12/28/2010 09:17 AM Balance: $0.00 Current Pmts 180.00 City of Tukwila 6200 Southcenter Blvd, Tukwila, WA 1 Finance Department 1036201 -1 12/28/2010 BR1 T108 Tue Dec28,2010 09 :23AM Trans #6 -7 6 $183.30 DCDGEN - DCD Permits Plus General Fund ID: IOT LOGISTICS Secondary ID: FRED BARBER 7 $180.00 DCDGEN - DCD Permits Plus General Fund ID: EWC GROUP Secondary ID: FRED BARBER 2 ITEM(S): TOTAL: $363.30 Visa PAID $363.30 www.ci.tukwila.wa.us 206- 433 -1835 bf:Fe - 27 0 INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION C 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431 =3670 Permit Inspection Request Line (206) 431 -2451 Project: FajC a1oiIP Address:_ {. APf Special Instructions: Type of Inspection: N PA Date Called: Date Wanted: { � 1 Requester: a.m. PM- Phone No: Approved per applicable codes. El Corrections required prior to approval. / r COMMENTS: p pf ).AN 1,014 412 Insp ctor: Date:9 14 REINSPECTION FEE'REQUIRED. Prior to next inspection, fee must be . paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. COMMENTS: Type of Inspection: N ei L 0 6 7 f Lam. / ( ' .; " Date Called: . 7_ -- 0,z2- - Date Wanted: . Requester: ... Z ,J p.i . - - pe f75 . - /Z ) e4 le-n/ iTt 4 0 4 -- xi , 4-- At 7--lq— i3 1 /7L d t-4 /$ , a / Project: - 'ct1C_ 6 ,?d i Type of Inspection: N ei L Add ,dress: y Date Called: . Special Instructions: 2 ;a, Date Wanted: . Requester: ... Phone No: INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431 -3670 Permit Inspection Request Line (206) 431 -2451 j Approved per applicable codes. ;y'v ,270 Corrections required prior to approval. .� Inspector Date: REIN ` SPECTION FEE REQ !RED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. Proje L.— L !/(.'. C *v Type of Inspection )1G- Address: , Date Called: Special IrFstfuctions /:00 Date Wanted:. �� L ��I c---. Pm. Requester: zsofr Phone N/ N 3 /49 -51227 Approved per applicable codes. rt INSPECTION RECORD Retain a copy with permit P f CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431 -3670 Permit Inspection Request Line (206) 431 -2451 PERMIT NO. COMMENTS: Meid ) a / - - 5 , , ez ,e ,: ( 1 3 .4.4)-11 / Corrections required prior to approval. n REINS CTION FEE UIRED. Prior to next inspection, fee m'c f be paid at 6300 Southcen -r Blvd.. Suite 100. Call to schedule reinspection. COMMENTS: Type of Inspection: ' f /)l" ei..4.+E >ss ,,r.4 40"- /S ---'' ,,otze r ` ilni ii.-- d1 Date Wanted :. ., Pte• lam / 3) -At,v40,..- Requester: , e.),/ .)-xe-d b. / 1— Phone No: 4 . •Zs ,z .,4"....t.< , „ii ,4 . . A . t .r 1. a . iri C 1 ,1 / Project: Type of Inspection: Address: Da e Called:. if Speua uctions: 3 :OR � G r : Date Wanted :. ,.-1,10 ,I a.m. Requester: , Phone No: INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431 -3670 Permit Inspection Request Line (206) 431 -2451 Approved per applicable codes. INSPECTION RECORD Retain a copy with permit L - 27cf PERMIT NO. Corrections required prior to approval. ❑ REIN PECTION REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspectioh. COMMENT / s--r..1) /0 IJJ �/ . • 1 S AJ &�- Ba f ( Jut o Jt -.' '()r . �s ,,�f J �- 4 � efrk () [..tj ll ' ^ c � " � � - " � ( - - / � .' f-fl J T1 £4 F 53f : Jpe , 7 L L 1 t! S'C -)4f;d; /2 t J .f ! . AC17 I , ./Gt e � 0 / 41A l1 T 11 ;L ,v v`- l />J.C_4 - (_ lA — !_p - Cr - :,r ,j t ..L - -- T.,_ /1 `rt - Q Ace - T-4; (1A G_„/ -ef4 . 1 " C r.'��� i � �1. ...11 � I, - t V (/� I i . L,r rs As 7l c , ,),,JAJLr ' ;.S cA CA61 & � c.;a�t AA efft ?13 k eel) [)fj 0 Pe At 1 MY Idly Project: �) �` V e _W� Type of Ic m 1.� , q / 'f'ch1tAr l C] Address: -1 ( 0 Akioo /U.f E. Date Called: Special Instructions: f� J^� )) Fir-e_ r 1(E4 k•L Date Wanted:. ?- lA — a.m. Requester: Z i&i rm ATI J Phone No: { r a INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. Ai CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 tr_. (206) 431 -367 Permit Inspection Request Line (206) 431 -2451 Approved per applicable codes. (Date Z' s� REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Inspector: 0 r Project: F_I& Q C., f26iP Type of Inspection: F'1 . Address: "I 1 0 A Nivc 12, Piz. Date Called: . Special Instructions: Date Wanted: a. Requester: Phone No: ,,166- 3IO -97O7 INSPECTION RECORD Retain a copy with permit ' ..7 . INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431 -3670 Permit Inspection Request Line (206) 431 -2451 D Approved per applicable codes. Corrections required prior to approval. COMMENTS: 3 \ F 40 4, PPQ pL0.l d,,,300A! P 44AF R4O * OCC/ Li Co 441 rYQ G —' aJb c o/C • Date: •. 7—' S - I ', aa� • SPECTION FEE REQUI D. Prior to nest inspection.. fee. must; her. at 6300 Southcenter Blvd.. Suite 100. Call to schedulereihspect{oni;, COMMENTS: A c C.'sS : ( P w c f zi 3J- AaS .--e. ) J`e V n i 'LS ! 'e , S et( ,/�� 1i- 1 1:/ e_ i - (t t, re / (uSP 7V 1 0 'M / AA-J ( 7O WA- ( — rl ;s Lo e ;,,��' Z1' k ;1 -- 1-e i 77" k . � - ( .... A -�J 4 P e CLr ✓�'1f k JiT C 7y., „t dc-61” / i at c r ■ 4 00 CI 2 , EA— A,re , t be I J L) C1' — ,'DT d v i / /',1,t o - dt-t Et: S 1 »A DJ( /(“-k Av7 DE, r4 . 5 ) in 4,t Ai e . '-SS : W T {s 7 /'o r) L-t S`j A� f e 01 L_n-'r.ii ,5I) C 0 C.() a.m. c .,4L. (ic L A U p-rs 0 kJ/ , '-4 z i Q. A v Project: ` / Type of InSpe t ` , ioti Address: -4( o 00 ✓�'1f k Date Called: Special Instructions: Date Wanted: a.m. Requester: Phone N 061 -2"7i INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 Approved per applicable codes. Corrections required prior to approval. Insp ctor: Date: `?-f.(d El $60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: Date: 7 V. �t-4- ,t 6 — ,. (Z e J -., 6 OM p A-: de- c erf,'4 i. pit: fc-- - , e 9 erf ..(4 ._ -‘-- Al * p ix .4--er Date Called: t k i-e 6: 0= p (t,M :� iPtIlli F_ 3-t 019 0.ek_ik-S DA A Date Wanted: - 7 - I -/0 a.m. 'T i? L €SS, ge _ ____ 1 yen AM i ei1 eit (. 1 PI I .c uJL c ),,,eLr & 5.fiA ; Nrr A0 A Ale-X. a C 6lp ;1GT S' g 6 d 1 1 ' .r- � J j 3 el /Mt Project: ul� Gi J�p Type nspection: , ( ,A u. i Address: 4(0 (0 Al 176<l'er Date Called: Special Instructions: Ivad c-i-elf - 1./`'7 1...,T. #l? . • Date Wanted: - 7 - I -/0 a.m. Requester: Phone No: n INSPECTION NO. p Approved per applicable codes. INSPECTION RECORD Retain a copy with permit PERMIT NO. CITY OF TUKWILA BUILDING DIVISION td• 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 Corrections required prior to approval. Instfector: 1 I / !• Date:1 $60.00 2EINSPECTION FEE REQUITED. Prior to inspection, fee must be paid at 6360 Southcenter Blvd:, Suite 100. Call to schedule reinspection. Receipt No.: Date: P Project: _ 10 C-7 Q � rr0 c ar Type of Inspect 'cf Irt , J c.. E l res Address: Li/0 Suite #: if t o 6 Contact Person: Special Instructions: Occupancy Type: Phone No.: Needs Shift Inspection: Sprinklers: Fire Alarm: Hood & Duct: Monitor: Pre -Fire: Permits: Occupancy Type: '/ INSPECTION NUMBER INSPECTION RECORD Retain a copy with permit CITY OF TUKWILA FIRE DEPARTMENT bo q - a7o PERMIT NUMBERS 444 Andover Park East. Tukwila, Wa. 98188 206 - 575 -4407 4 2 6\pproved per applicable codes. Corrections required prior to approval. COMMENTS: - 1 vJ L —off C c s $ cA-N Lx►v %CR.) OA O+ 1 LI Inspector: a Date: Hrs.: j $100.00 REINSPECTION FEE REQUIRED. You will receive an invoice from the City of Tukwila Finance Department. Call to schedule a reinspection. Billing Address Attn: I Company Name: Address: City: State: I Zip: Word /Inspection Record Form.Doc 6/11/10 T.F.D. Form F.P. 113 COMMENTS: /� yrroc.,c vo Type of Inspection: 1 f -P 55 Address: �.J p Suite #: __ (( p r Contact Person: Special Instructions: Phone No.: Pre -Fire: ' Permits: N, Occupancy Type: 401 1 . 0 F, , c `7 Lei , 4.,( f �r �T (!e p(PC i 0_ C_`.!u e ( i 1 C. `( �(' f ( l Q 7 r l( (7, i 4 Y / f / 9 WI 17 { "f'.eArd u k S 4,01 ic, i , IlltA.,( FIX I- 390, s , J Project: _ Etc ( /� yrroc.,c vo Type of Inspection: 1 f -P 55 Address: �.J p Suite #: __ (( p r Contact Person: Special Instructions: Phone No.: Needs Shift Inspection: Sprinklers: Fire Alarm: Hood & Duct: Monitor: Pre -Fire: ' Permits: N, Occupancy Type: INSPECTION NUMBER CITY OF TUKWILA FIRE DEPARTMENT 444 Andover Park East, Tukwila, Wa. 98188 Approved per applicable codes. Billing Address Word /Inspection Record Form.Doc INSPECTION RECORD Retain a copy with permit 6/11/10 .Q 70 PERMIT NUMBERS 206 - 575 -4407 Corrections required prior to approval. Inspector: Hrs.. . / Date: 3 / e f n $100.00 REINSPECTION FEE REQUIRED. You will receive an invoice from the City of Tukwila Finance Department. Call to schedule a reinspection. Attn: State: Address: City: Company Name: Zip: T.F.D. Form F.P. 113 COMMENTS: Type of Inspection: EA._ Fire Alarm: Address: t.//0 4- p E Suite #: Contact Person: Veded 1 S-t c) & S ?oof 1%J E'(4 - "ii- 4i , Special Instructions: Phone No.: ° U Ojvd4„-- 1;y1 i-. ia11 _ bee; 4 k: k . -- 1 ' ik) /24 : N- per- fin) Project: , - • EAR_ 61,-01,10 Type of Inspection: EA._ Fire Alarm: Address: t.//0 4- p E Suite #: Contact Person: • Special Instructions: Phone No.: Needs Shift Inspection: Sprinklers: Fire Alarm: Hood & Duct: Monitor: Pre -Fire: Permits: Occupancy Type: r INSPECTION NUMBER CITY OF TUKWILA FIRE DEPARTMENT Approved per applicable codes. INSPECTION RECORD Retain a copy with permit Dog- .7• PERMIT NUMBERS 444 Andover Park East, Tukwila, Wa. 98188 206 - 575 -4407 -.Corrections required prior to approval. Inspector: Date: 6/i 1 H $100.00 REINSPECTION FEE REQUIRED. You will receive an invoice from the City of Tukwila Finance Department. Call to schedule a reinspection. . Billing Address Attn: Address: City: Company Name: State: I Zip: Word /Inspection Record Form.Doc 6/11/10 T.F.D. Form F.P. 113 FILE COPY Permit No. STRUCTURAL DESIGN FOR NEW MAN DOOR AND STEEL EXIT STAIRS FOR EWC GROUP, INC. PCL WAREHOUE PLAN 410 ANDOVER PARK E TUKWILA, WA 98188 November 11, 2010 [B &T Project No. 10107] B & T Design & Engineering, Inc. P.O. Box 595 • Issaquah, WA 98027 • Office: 425 - 557 -0779 • RECEIVED CITY OF TUKWILA NOV 16 2010 PERMIT CENTER REVIEWED FOR CODE COMPLANCE PPD AVED NUV 19 2010 City of Tukwila BUILDING DIVISION i � wr N Fax: 425.557 -0705 12 ° r B&T Design & Engineering, Inc. 10107 - 410 Andover Park E (425) 557 -0779 Stair Loading & Criteria Stringers: DL (psf) = LL (psf) = Duration Factor = Additional DL (pif) = 5 1.00 1.0 Member: Horizontal Length (ft) = Total uniform design Toad (pif) = 218 Maximum Bending force (K -ft) = 0.85 Maximum End Reaction (K) = 0.61 1 5.58 Material Properties: Fy (ksi) = E (ksi) = Max. Deflection [L/ ?] = Stair Width (ft) = Tread (in) = Riser (in) = a (deg) = Try: 50 : 29,000 360 4.00 11.0 6.85 31.9 I MC10x8.4 I Sx (in "3) = 6.39 Okay Sreq'd (inA3) = 0.31 Ix (in "4) = 31.9 Okay Ireq'd (in"4) = 1.44 Wt (plf) = 8.4 Steel Stair Design Page 1 11/10/2010 B&T Design & Engineering, Inc. (425) 557 -0779 Landing: Member: Length (ft) = T.W. (ft) = P (lb) = furthest distance from support "a" (ft) = 609 4.0 Total uniform design load (plf) = 157 Maximum Bending force (K -ft) = 0.80 Maximum End Reaction (K) = 0.88 Member: Length (ft) = T.W. (ft) = P (lb) _ furthest distance from support "a" (ft) = Total uniform design load (plf) = 297 Maximum Bending force (K -ft) = 0.93 Maximum End Reaction (K) = 0.74 5.0 2.75 0:0 10107 - 410 Andover Park E TN: T C6x8.2 Sx (in "3) = 4.35 Okay Sreq'd (in"3) = 0.29 Ix (in "4) = 13.1 Okav Ireq'd (in04) = 0.46 Wt (plf) = 8.2 C6x8.2 Sx (in "3) = 4.35 Okav Sreq'd (in "3) = 0.33 Ix (in "4) = 13.1 Okay Ireq'd (in "4) = 0.86 Wt (plf) = 8.2 Steel Stair Design Page 2 11/10/2010 B&T Design & Engineering, Inc. (425) 557 -0779 Handrails: Posts: height (ft) = Max horizontal post spacing (ft) = Top rail design Toad (plf) = 68 Maximum Bending force (K -ft) = 0.60 Maximum Reaction at base (K) = 0.20 I 3 2.5 0 10107 - 410 Andover Park E Try: I 1 -1/4" STD I Sx (in ^3) = 0.235 Okav Ix (in "4) = 0.195 Okav Wt (plf) = 2.27 Sreq'd (in "3) = 0.22 Ireq'd (in^4) = 0.18 Steel Stair Design Page 3 11/10/2010 B&T Design & Engineering, Inc. (425) 557 -0779 10107 - 410 Andover Park E Panel Opening Page 1 11/10/2010 i ■ x�•.1J •tit I C LIZ Fl St4DO WALL- , 5I lJ Y: - G• 91' CASE, AG14.1 'rdP1t 5N:1\jESr Gf N E OFF CC #2 t d Rs t .y4 . *� r - �(i - :.. $.�. � �', r �liv 1Ef WicEinni= 1 1111Enall �il:9� g1_ lSS - :TnTaDZ bi: 1 '�.tt+In- n A[r!6r^.'IRhi!1r..'J ;t - ._......wcaear;3;r . .-,_+ ,; ..y. .d4til; ..; . fkcc ghTnnaor1 $ N STa't nlrc L I ayc a3 3,3 1 _ 3)" . �t8o�t h ';AN 1 V ' Loh 7 • I• 70 orn n Fri CM Y :D7 (= M o < -1 FIX/1 0 1-40N(J1CA I' TT H 36 OFFICE 1 C 3O" UP rc R'ULt. t AIa.S. 511 �G�!�.�,. 4-a SMILE t ROD -. 441- q,. 0 1 � c " .1x IGO co • 3 1 car 0 • a o era 0 4 • • DA _ R c; K1 - Pi t7z) 13.p 11 "oEI=ARA E PERMIT- REQUIRED FOR- -- Mechanical 14 Electrical Plimbing c 1 • z m — .._ _ KAN ,. (Aix/ J -' te ) u E- 2.430 R Gv�r1 4 ceeyviply AD 4 Goles ctiov40fr 5 f 4 -02, • r..) R" PAGE • • • • • • 39 �d sa,vDs 5 il c - .):.1 _L. id "5 1 rd 1-11111N-Id , f'f v41.101S .L , \x'S / H ^,s N11 r-id d — e 100L1 \u - ':t n tZ:hGtd - O•ZZ z EC.r.ru ,Q = '717: ALL r-4 i -_) . ■?.1 PZ nd( 7 irvoo ill ;A`di 3;OH „Ln, S'IZ fi '54 . 7 „431 x >t „81 z�anc � cv\ 1 \ bcJ 7\1-'1•4 Sd „Z J /A C)vd r ?■ FA • � � � 0 - '® - Q Ull WIC I— C co UM co �, � Z ' ® CC ® M I 1 a�lr�wd. •',tVO „0.. >A4:P •s. I d 1 m r R c 0 U r a Ul 0 0 i+ b - Frr i;eAvLet Fr e B, 12 0 efx,,.P...133 US B g U "" 4° 76 M - _ cn Id ai -/ _a-Crn rz., = > " D 7. i'iuvrvt) LA'n(A.) 411 P 13.\070 GaooG 002e,,r- Ac 1-4, A+ "-HD P1=- • Tu 4 c- PLANO BROS. PAVING, INC. P.O. BOX 2295 RENTON, WASH. 98056 J1 i. 3) 0 PAGE PLANO BROS. PAVING, INC. P.O. BOX 2295 RENTON, WASH. 98056 09 -04 -2012 FRED BARBER 7979 S 180 ST KENT WA 98032 RE: Permit No. D09 -270 EWC GROUP 410 ANDOVER PK E TUKW Dear Permit Holder: City of Tukwila In reviewing our current records, the above noted permit has not received a final inspection by the City of Tukwila Building Division. Per the International Building Code, International Mechanical Code, Uniform Plumbing Code and/or the National Electric Code, every permit issued by the Building Division under the provisions of these codes shall expire by limitation and become null and void if the building or work authorized by such permit has not begun within 180 days from the issuance date of such permit, or if the building or work authorized by such permit is suspended or abandoned at any time after the work has begun for a period of 180 days. Your permit will expire on 10/14/2012. Based on the above, you are hereby advised to: Jim Haggerton, Mayor -or- Department of Community Development Jack Pace, Director 1) Call the City of Tukwila Inspection Request Line at 206 -431 -2451 to schedule for the next or final inspection. Each inspection creates a new 180 day period, provided the inspection shows progress. 2) Submit a written request for permit extension to the Permit Center at least seven (7) days before it is due to expire. Address your extension request to the Building Official and state your reason(s) for the need to extend your permit. The Building Code does allow the Building Official to approve one extension of up to 180 days. If it is determined that your extension request is granted, you will be notified by mail. In the event you do not call for an inspection and/or receive an extension prior to 10/14/2012, your permit will become null and void and any further work on the project will require a new permit and associated fees. Thank you for your cooperation in this matter. Sincerely, Bill Rambo Permit Technician File: Permit File No. D09 -270 6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone 206 -431 -3670 • Fax 206-431 -3665 FRED BARBER 7979 S 180 ST KENT WA 98032 RE: Permit No. D09 -270 EWC GROUP 410 ANDOVER PK E TUKW Dear Permit Holder: In reviewing our current records, the above noted permit has not received a final inspection by the City of Tukwila Building Division. Per the International Building Code, International Mechanical Code, Uniform Plumbing Code and/or the National Electric Code, every permit issued by the Building Division under the provisions of these codes shall expire by limitation and become null and void if the building or work authorized by such permit has not begun within 180 days from the issuance date of such permit, or if the building or work authorized by such permit is suspended or abandoned at any time after the work has begun for a period of 180 days. Your permit will expire on 02/22/2012. Based on the above, you are hereby advised to: The Building Code does allow the Building Official to approve one extension of up to 180 days. If it is determined that your extension request is granted, you will be notified by mail. In the event you do not call for an inspection and/or receive an extension prior to 02/22/2012, your permit will become null and void and any further work on the project will require a new permit and associated fees. Thank you for your cooperation in this matter. Sincerely, 1) Call the City of Tukwila Inspection Request Line at 206 -431 -2451 to schedule for the next or final inspection. Each inspection creates a new 180 day period, provided the inspection shows progress. -or- 2) Submit a written request for permit extension to the Permit Center at least seven (7) days before it is due to expire. Address your extension request to the Building Official and state your reason(s) for the need to extend your permit. Bill Rambo Permit Technician File: Permit File No. D09 -270 • City of Tukwila Department of Community Development Jack Pace, Director Jim Haggerton, Mayor 6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone: 206 - 431 -3670 • Fax: 206 - 431 -3665 FRED BARBER 7979 S 180 ST KENT WA 98032 RE: Permit No. D09 - 270 410 ANDOVER PK E TUKW Dear Permit Holder: In reviewing our current records, the above noted permit has not received a final inspection by the City of Tukwila Building Division. Per the International Building Code, International Mechanical Code, Uniform Plumbing Code and/or the National Electric Code, every permit issued by the Building Division under the provisions of these codes shall expire by limitation and become null and void if the building or work authorized by such permit has not begun within 180 days from the issuance date of such permit, or if the building or work authorized by such permit is suspended or abandoned at any time after the work has begun for a period of 180 days. Your permit will expire on 07/04/2011. Based on the above, you are hereby advised to: Sincerely, 1) Call the City of Tukwila Inspection Request Line at 206 - 431 -2451 to schedule for the next or final inspection. Each inspection creates a new 180 day period, , provided the inspection shows progress. -or- 2) Submit a written request for permit extension to the Permit Center at least seven (7) days before it is due to expire. Address your extension request to the Building Official and state your reason(s) for the need to extend your permit. The Building Code does allow the Building Official to approve one extension of up to 180 days. If it is determined that your extension request is granted, you will be notified by mail. In the event you do not call for an inspection and/or receive an extension prior to 07/04/2011, your permit will become null and void and any further work on the project will require a new permit and associated fees. Thank you for your cooperation in this matter. A),9 Bill Rambo Permit Technician File: Permit File No. D09 -270 • City of Tukwila Jim Haggerton, Mayor Department of Community Development Jack Pace, Director ' 6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone: 206 - 431 -3670 • Fax: 206- 431 -3665 January 3, 2011 Fred Barber 7979 S 180 St Kent, WA 98032 Dear Mr. Barber, Sincerely, • . ity f Tu u 'ila File: Permit No. D09 -270 Department of Comm r nit,' RE: Request for Extension Development Permit No D09 -270 EWC Group — 410 Andover Pk E 1? Jim Haggerton, Mayor evelopment Jack Pace, Director This letter is in response to your written request for an extension to Permit Number D09 -270. The Building Official has reviewed your letter and considered your request to extend the above referenced permits. The City of Tukwila Building Division will be extending your permits an additional 180 days from the date of expiration, through July 4, 2011, as requested. If you should have any questions, please contact our office at (206) 431 -3670. W:\Permit Center\Extension Letters \Pennits\2009\D09 -270 Permit Extension.doc 6300 Southcenter Boulevard, Suite #100 0 Tukwila, Washington 98188 0 Phone: 206 - 431 -3670 o Fax: 206 - 431 -3665 T�6 13C) C1. &ENE 2L EAS t.X"TtTh O • • n o roz crcpr Fto G: T o T H ti. 11 41 N K c j :?K, TO 6-X7"-C--Alt, poem I^ ik4r10a gy /So v4p III 01 -03 -0011 r4 n Qn 270 bVE To a k .f'G.Z P i- P a a -TT FIECENED OF 'DEC 2 8 Z010 9 FAMIT CENTS; ■►-es l -S- t 0 I Oy 1 1 1 4 -17 - FRED BARBER 7979 S 180 ST KENT WA 98032 RE: Permit No. D09 -270 410 ANDOVER PK E TUKW Dear Permit Holder: Sincerely, -or- Bill Rambo Permit Technician File: Permit File No. D09 -270 • Dep rtment ; j Comm 1 i mild Development In reviewing our current records, the above noted permit has not received a final inspection by the City of Tukwila Building Division. Per the International Building Code, International Mechanical Code, Uniform Plumbing Code and/or the National Electric Code, every permit issued by the Building Division under the provisions of these codes shall expire by limitation and become null and void if the building or work authorized by such permit has not begun within 180 days from the issuance date of such permit, or if the building or work authorized by such permit is suspended or abandoned at any time after the work has begun for a period of 180 days. Your permit will expire on 01/05/2011. Based on the above, you are hereby advised to: 1) Call the City of Tukwila Inspection Request Line at 206 - 431 -2451 to schedule for the next or final inspection. Each inspection creates a new 180 day period, , provided the inspection shows progress. 2) Submit a written request for permit extension to the Permit Center at least seven (7) days before it is due to expire. Address your extension request to the Building Official and state your reason(s) for the need to extend your permit. The Building Code does allow the Building Official to approve one extension of up to 180 days. If it is determined that your extension request is granted, you will be notified by mail. Thank you for your cooperation in this matter. Jim Haggerton, Mayor In the event you do not call for an inspection and /or receive an extension prior to 01/05/2011, your permit will become null and void and any further work on the project will require a new permit and associated fees. Jack Pace, Director 6300 Southcenter Boulevard, Suite #100 0 Tukwila, Washington 98188 • Phone: 206 - 431 -3670 a Fax: 206 - 431 -3665 FRED BARBER 7979 S 180 ST KENT WA 98032 Dear Permit Holder: IIP RE: Permit No. D09 -270 410 ANDOVER PK E TUKW • Department of Community Development In reviewing our current records, the above noted permit has not received a final inspection by the City of Tukwila Building Division. Per the International Building Code, International Mechanical Code, Uniform Plumbing Code and /or the National Electric Code, every permit issued by the Building Division under the provisions of these codes shall expire by limitation and become null and void if the building or work authorized by such permit has not begun within 180 days from the issuance date of such permit, or if the building or work authorized by such permit is suspended or abandoned at any time after the work has begun for a period of 180 days. Your permit will expire on 07/10/2010. Based on the above, you are hereby advised to: Jim Haggerton, Mayor Jack Pace, Director 1) Call the City of Tukwila Inspection Request Line at 206 - 431 -2451 to schedule for the next or final inspection. Each inspection creates a new 180 day period. -or- 2) Submit a written request for permit extension to the Permit Center at least seven (7) days before it is due to expire. Address your extension request to the Building Official and state your reason(s) for the need to extend your permit. The Building Code does allow the Building Official to approve one extension of up to 180 days. If it is determined that your extension request is granted, you will be notified by mail. In the event you do not call for an inspection and /or receive an extension prior to 07/10/2010, your permit will become null and void and any further work on the project will require a new permit and associated fees. Thank you for your cooperation in this matter. Sincerely, C Bill Rambo Permit Technician File: Permit File No. D09 -270 6300 Southcenter Boulevard, Suite #100 0 Tukwila, Washington 98188 0 Phone: 206 - 431 -3670 0 Fax: 206 - 431 -3665 ACTIVITY NUMBER: D09 -270 PROJECT NAME: SITE ADDRESS: EWC GROUP, INC. 410 ANDOVER PK E DATE: 11116/10 Original Plan Submittal Response to Incomplete Letter # Response to Correction Letter # X Revision # 1 after Permit Issued DEPARTMENTS: Building Division II Pi lt'clNork " Ai 11 DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete VI Comments: Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: TUES /THURS ROUTING: Building Please Route REVIEWER'S INITIALS: APPROVALS OR CORRECTIONS: HERMIT COORD COPY PLAN REVIEW /ROUTING SLIP Structural Incomplete Approved n Approved with Conditions Notation: REVIEWER'S INITIALS: Documents/routing slip.doc 2 -28 -02 4� ,��,� li—t0 P N�/� «. II � t1 tre Preventi Pan ning Division Structural Review Required n No further Review Required n Permit Coordinator DUE DATE: 11/18/10 DATE: Not Applicable n DUE DATE: 12/16/10 Not Approved (attach comments) DATE: Permit Center use O CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials:_ _ DEPARTMENTS: A?Ilding ivision ►� � �� - •0 Pu Ic Wor s Documents /routing slip.doc 2 -28 -02 r ! PE PLAN REVIEW /ROUTING SLIP DATE: 12 -30 -09 ACTIVITY NUMBER: D09 -270 PROJECT NAME: EWC GROUP SITE ADDRESS: 410 ANDOVER PK E X Original Plan Submittal Response to Incomplete Letter # Response to Correction Letter # Revision # After Permit Issued ire Preven ion Structural DETERMINATION OF COMPLETENESS: (Tues., Thurs.) DUE DATE: 12 -31 -09 Complete ❑ Incomplete ❑ Comments: Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: TUES/THURS ROUTING: Please Route ❑ Structural Review Required 1 No further Review Required REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: Approved ❑ Approved with Conditions Notation: s ti M Planning Division U Permit Coordinator Not Applicable DUE DATE: 01 -28 -10 Not Approved (attach comments) ❑ REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: REVISION NO. DATE RECEIVED STAFF INITIALS ISSUED DATE STAFF INITIALS 1 It UAW ►, -a4- (o Summary of Revision: 1 1(L Received by: REVISION NO. DATE RECEIVED STAFF INITIALS ISSUED DATE STAFF INITIALS 1 It UAW ►, -a4- (o Summary of Revision: 1 1(L Summ. of Revision: t A► 1.0. .AA ,. . i ■ A • .A. •k i . ' _ i'A trar r Received by fl 13 A,4 0 Et REVISION NO. DATE RECEIVED STAFF INITIALS ISSUED DATE STAFF INITIALS Summary of Revision: Received by: REVISION NO. DATE RECEIVED STAFF INITIALS ISSUED DATE STAFF INITIALS Summary of Revision: Received by: REVISION NO. DATE RECEIVED STAFF INITIALS ISSUED DATE STAFF INITIALS Summary of Revision: Received by: REVISION NO. DATE RECEIVED STAFF INITIALS ISSUED DATE STAFF INITIALS Summary of Revision: Received by: PROJECT NAME: SITE ADDRESS: REVISION LOG PERMIT NO: -- 210 ORIGINAL ISSUE DATE: Ot[ t I 10 (please print) (please print) (please print) (please print) (please print) Revision submittals must be submitted in person at the Permit Center. Revisions will not be accepted through the mail, fax, etc. Date: t k ` O 1 O Project Name: Project Address: Contact Person: r Summary of Revision: Entered in Permits Plus on H:Wpplications\Forms- Applications On Line\2010 Applications 7 -2010 - Revision Submitial.doc Crested: 8 -13 -2004 Revised: 7 -2010 4 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Web site: http: //www.ci.tukwila.wa.us Plan Check/Permit Number: ❑ Response to Incomplete Letter # ❑ Response to Correction Letter # 1;5.5 Revision # t after Permit is Issued ❑ Revision requested by a City Building Inspector or Plans Examiner F; 6fir-c) r.ic, Sheet Number(s): - _. - "Cloud" or highlight all areas of revision including date of revision REVISION SUBMITTAL D01- 2'l0 ; L4 OV 16 2010 P fturce iren Phone Number: (cCs) -7 7 f czizsi /tc 1 S)en -k Received at the City of Tukwila Permit Center by: STATE OF WASHINGTON) COUNTY OF KING ) r CITY OF TUKWILA Department of Community Development 6300 Southcenter Boulevard, Tukwila, WA 98188 Telephone: (206) 431 -367o FAX (206) 431 -3665 E - mail: tukplanc ci.tukwila.wa.us AFFIDAVIT IN LIEU OF CONTRACTOR REGISTRATION ss. Permit Center /Building Division 206 431 -3670 Public Works Department 206 433 -0179 Planning Division 206 431 -3670 PERMIT NO: DDS --2-1 D FRED g ,g`C,-, states as follows: [please print name] 1. I have made application for a permit from the City of Tukwila, Washington. 2. I understand that state law requires that all building construction contractors be registered with the State of Washington. The exceptions to this requirement are stated under Section 18.27.090 of the Revised Code of Washington, a copy of which is printed on the reverse side of this Affidavit. I have read or am familiar with RCW 18.27.090. 3. I understand that prior to issuance of a permit for work which is to be done by any contractor, the City of Tukwila must verify either that the contractor is registered by the State of Washington, or that one of the exemptions stated under RCW 18.27.090 applies. 4. In order to provide verification to the City of Tukwila of my compliance with this requirement, I hereby attest that after reading the exemptions from the registration requirement of RCW 18.27.090, I consider the work authorized under this permit to be exempt under number I; , and will therefore not be performed by a registered contractor. 5. I understand that the licensing provision of RCW 19.28.161 through 19.28.271 shall not apply to persons making electrical installations on their own property or to regularly employed employees working on the premises of their employer. The proposed electrical work is not for the construction of a new building for rent, sale or lease. I understand that I may be waiving certain rights that I might otherwise have under state law in any decision to engage an unregistered contractor to perform construction work. Owner /Owner's Agent* Signed and sworn to before me this day of V.ante NOTARY PUBLIC in and for the State of Washington Residing at C4f10, Name as commissioned: My commission expires: , County 7 'I L° /I ttfr D5 - -a9 -/ ,20 • 18 27,090 Exemptions. The registration provisions of this chapter do not apply to: IS 1. An authorized representative of the United States government, the state of Washington, or any incorporated city, town, county, township, irrigation district, reclamation district, or other municipal or political corporation or subdivision of this state; 2. Officers of a court when they are acting within the scope of their office; 3. Public utilities operating under the regulations of the utilities and transportation commission in construction, maintenance, or development work incidental to their own business; 4. Any construction, repair, or operation incidental to the discovering or producing of petroleum or gas, or the drilling, testing, abandoning, or other operation of any petroleum or gas well or any surface or underground mine or mineral deposit when performed by an owner or lessee; 5. The sale of any finished products, materials, or articles of merchandise that are not fabricated into and do not become a part of a structure under the common law of fixtures; 6. Any construction, alteration, improvement, or repair of personal property performed by the registered or legal owner, or by a mobile /manufactured home retail dealer or manufacturer licensed under chapter 46.7o RCW who shall warranty service and repairs under chapter 46.70 RCW; 7. Any construction, alteration, improvement, or repair carried on within the limits and boundaries of any site or reservation under the legal jurisdiction of the federal government; 8. Any person who only furnished materials, supplies, or equipment without fabricating them into, or consuming them in the performance of, the work of the contractor; 9. Any work or operation on one undertaking or project by one or more contracts, the aggregate contract price of which for labor and materials and all other items is less than five hundred dollars, such work or operations being considered as of a casual, minor, or inconsequential nature. The exemption prescribed in this subsection does not apply in any instance wherein the work or construction is only a part of a larger or major operation, whether undertaken by the same or a different contractor, or in which a division of the operation is made into contracts of amounts less than five hundred dollars for the purpose of evasion of this chapter or otherwise. The exemption prescribed in this subsection does not apply to a person who advertises or puts out any sign or card or other device which might indicate to the public that he or she is a contractor, or that he or she is qualified to engage in the business of contractor; 10. Any construction or operation incidental to the construction and repair of irrigation and drainage ditches of regularly constituted irrigation districts or reclamation districts; or to farming, dairying, agriculture, viticulture, horticulture, or stock or poultry raising; or to clearing or other work upon land in rural districts for fire prevention purposes; except when any of the above work is performed by a registered contractor; 11. An owner* who contracts for a project with a registered contractor, except that this exemption shall not deprive the owner of the protections of this chapter against registered and unregistered contractors. The exemption prescribed in this subsection does not apply to a person who performs the activities of a contractor for the purpose of leasing or selling improved property he or she has owned for less than twelve months; 12. Any person working on his or her own property, whether occupied by him or her or not, and any person working on his or her personal residence, whether owned by him or her or not but this exemption shall not apply to any person who performs the activities of a contractor on his or her own property for the purpose of selling, demolishing, or leasing the property; 13. An owner* who performs maintenance, repair, and alteration work in or upon his or her own properties, or who uses his or her own employees to do such work; 14. A licensed architect or civil or professional engineer acting solely in his or her professional capacity, an electrician certified under the laws of the state of Washington, or a plumber certified under the laws of the state of Washington or licensed by a political subdivision of the state of Washington while operating within the boundaries of such political subdivision. The exemption provided in this subsection is applicable only when the person certified is operating within the scope of his or her certification; 15. Any person who engages in the activities herein regulated as an employee of a registered contractor with wages as his or her sole compensation or as an employee with wages as his or her sole compensation; 16. Contractors on highway projects who have been prequalified as required by RCW 47.28.070, with the department of transportation to perform highway construction, reconstruction, or maintenance work; 17. A mobile /manufactured home dealer or manufacturer who subcontracts the installation, set -up, or repair work to actively registered contractors. This exemption only applies to the installation, set -up, or repair of the mobile /manufactured homes that were manufactured or sold by the mobile /manufactured home dealer or manufacturer; 18. An entity who holds a valid electrical contractor's license under chapter 19.28 RCW that employs a certified journeyman electrician, a certified residential specialty electrician, or an electrical trainee meeting the requirements of chapter 1g.28,RCW to perform plumbing work that is incidentally, directly, and immediately appropriate to the like -in -kind replacement of a household appliance or other small household utilization equipment that requires limited electric power and limited waste and /or water connections. An electrical trainee must be supervised by a certified electrician while performing plumbing work. • Per Washington State Department of Labor and industries, lessee has been interpreted to be equivalent to owner for the purpose of these exemptions. FE t G PY No, Per mft N Plan review approval is subject to errors and omissions. Approval of construction documents does not authorize the violation of any adopted code or ordinance. Receipt of approved and coalitions is acknowledged: By Data: .s 2 12 42010 City Of Tukwila BUILDING DIVISION 'RESERVED PARKING PAR cp.Q pow !MOUNTED VAN AfxLiML� FINISH GRADE • PARKING STALL TYPICAL ACCESSIBLE PARKING SIGNAGE NO SCALE REVISIONS No r arrges shall be m de to the scope Gi z` without prior approval of '" ;'°s° ^wila Building Division. - 1vs inns will require a new plan submittal gay inc;ude additional plan review fees. INTERNATIONAL SIGN OF ACCESSIBILITY LETTERING PER ICC /ANSI A117.1 CHAPTER 7 LETTERING SHALL BE WHITE ON A BLUE BACKGROUND SIGN TO BE POSTED ON VAN ACCESSIBLE STALL ONLY SEPARATE PERMIT REQUIRED FOR Iel Mechanical Mlectrical 'i''lumbing Cedas Piping City of Tukwila B:' WING DIVISION 0 i i ID (El EXIT DOOR & STAIR TO GRADE INTERNATIONAL SYMBOL OF ACCESS PAINTED ON PAVING (E) PLC STORAGE RIMER SEPARATE PERMITI (E) EWC STORAGE SITE PLAN 10 20 SCALE: r=20' 40 le) ASPHALT RAMP SIGN MARKED W/ INTERNATIONAL SYMBOL OF ACCESS & BEARS THE WORDS "STATE DISABLED PARKING PERMIT REQUIRED ". SIGN SHALL BE 60" MINIMUM ABOVE PARKING SPACE GRADE TO BOTTOM OF SIGN. LOCATE ADDITIONAL SIGN STATING "VAN ACCESSIBLE" BELOW PREVIOUS SIGN. - N C RECEIV D CITYOFTU LA NOV 17 2010 PERMIT CENTER NEW GATE IN le) FENCE NEW COMPACTED GRAVEL PATH TO GATE NEW EXIT DOOR & STAIR TO FINISHED GRADE /_ (E) FENCE REVIEWED FOR CODE COMPLIANCE APPROIVED NOV 19 2010 tL U4- City of Tukwila BUILDING DIVISION REVISION N CC z < w () P CC OD clg° w O W O > CC 14 0 w § u ( 03 CC CI he Z Li 0 U ur 0_ PROJECT DATE DRAWN CHKD. SHEET 10107 LIGHTING LEGEND MARK FIXTURE DESCRIPTION WATTS/ FIXTURE 4 LAMP T5H0 LIGHT FIXTURE 216 1Q1 LIGHTED EXIT SIGN N/A II!$ tor . ..di / 1 / A r ___/ EXIT PATH /Z./if ' , //— TYPICAL EMERGENCY LIGHTING PER NOTE 2. 48' -0" 65' -0" 165' -0" 0 0 0 65' -0" F/51.1 S1.1 SIM NEW 2 X 4 • c.c. l i INFILL WALL NEW COMPACTED GRAVEL PATH PROJECT 10107 DATE 11/16/10 0 N Q N N N N 191 (EI EWC OFFICE 50' -O" EXITING NOTES: 1. ALL EXITS TO THE EXTERIOR OF THE BUILDING SHALL bE ILLUMINATED AND SIGNED PER 2006 IBC SECTIONS 1006 & 1011. THESE EXITS ARE DENOTED BY 1191) ON THE PLAN. PROVIDE DIRECTIONAL EXIT SIGNS AND PLACE THEM SO THAT EXIT SIGNS ARE READILY VISIBLE FROM ANY DIRECTION OF EGRESS TRAVEL PER 2006 IBC SECTION 1011.1. PLACE EXIT SIGN SUCH THAT NO POINT IN AN EXIT ACCESS CORRIDOR IS MORE THAN 100 FEET FROM THE NEAREST VISIBLE EXIT SIGN. PROVIDE (2) BULB BACKUP, TYPICAL. (9) BULB BACKUP REQUIRED AT EACH DOORWAY. 2. PROVIDE EMERGENCY POWER TO THE REQUIRED EGRESS ILLUMINATION FIXTURES PER 2006 IBC SECTION 1006.9. PROVIDE EMERGENCY POWER AT ALL EXIT ACCESS PATHWAYS. EXIT STAIRWAYS PER 2006 IBC SECTION 1006.9. EMERGENCY POWER SYSTEM SHALL PROVIDE POWER FOR A MINIMUM OF 90 MINUTES. LEGEND • s EXISTING RACKS 65' -0" 245' -0" 65' -0" FLOOR PLAN 3/32" = 1' -0" NEW EXIT DOOR PLAN VIEW B /S1.1 2 . 0 95' -0" 65' -0" NEW GATE a O • (E) EXIT DOOR STAIR REVIEWED FOR CODE COMPLIANCE A P DQnVED NUV 19 2010 City of Tukwila BUILDING DIVISION RECEIVED CITY OF TUKwLA NOV 17 2010 PERMIT CENTER SHEET : A2.1 1/4" PLATE W/— (2) 1/2 "• X 3 1/2" WEDGE ANCHORS 1 1/4" DETAIL "a" (E) WOOD COL NEW 4 X 12 TOP PLATE W/ NEW SIMPSON L70 CLIPS EA SIDE ITYP) (E) DBL PLATE SECTION DETAIL "f" (E) ROOFING (E) 4 X PURLINS (E) FIRE RETARDENT VINYL SHEETING (NEW FIRE RETARDENT VINYL SHEETING O SIM CONDITION) C10 X 15.3 W/ 5/8"1 X 3 1/2" WEDGE ANCHORS 0 36 "o.c. NEW 4 X 12 TOP PLATE BETWEEN (E) COLS (E) 2 X 4 0 24 "o.c. STUD WALL W/ 1/2" PLYWOOD EA SIDE BETWEEN IEI 10 X 10 BLDG COLUMMS (NEW 2 X 4 • 24 "o.c. STUD WALL W/ 1/2" PLYWOOD EA SIDE • SIM CONDITION) (E) 1/2"1 X 4 1/2" WEDGE ANCHORS 0 24 "o.c. (NEW 1/2 "/ X 4 1/2" WEDGE ANCHORS 0 24 "o.c. • SIM CONDITION) (E) 5" SLAB ON GRADE (E) CONC WALL 3/16 SECTION NEW MANDOOR W/ STEEL FRAME CUT OUT NEW MAN DOOR 24 "/ OPENING SECTION 1 1/2" SECTION - 1 1/4"t (SCHED 'FOi' HORIZ 1 1/4"1 (SCHED 40) CONT HANDRAIL EA SIDE OF STAIR (NO HANDRAIL 0 SIM CONDITION) -1 1/4 "1 (SCHED 40) VERTICAL -1 1/4 "e (SCHED 40) HORIZ RY -WELD STEEL BAR OR APPROVED EQUAL GRATING (3/4" X 1/8" FOR 2' -6" SPAN) (10 -W -4) 3/8" X 0' -5" SQ PLATE X3X3 /16 HSS W/ (4) 1/2 "e X 3" W.H.S. GUARDRAIL PER SECTION D /S1.1 C6 PER PLAN 24 "e (2500 PSI) SONOTUBE -RY -WELD STEEL BAR OR APPROVED EQUAL GRATING (3/4" X 1/8" FOR 2' -6" SPAN) (10 -W -4) r-4X3X1/4 "XO' -6" W/ (2) 3/8 "e X 3" WEDGE ANCHORS & (2) 3/8"1 (A307) BOLTS 3' -0" EQ 1/4 VE ICAL 1 "1 (SCHED 40) VERTICAL 0 5 1 /4 "o.c. MAX 1 1/4 "e (SCHED 40) HORIZ 3.7/8" MAX CLR -C6 PER PLAN 1 1/4 "1 (SCHED 40) CONT HANDRAIL EA SIDE OF STAIR & LANDING HSS COL PER PLAN SECTION HANDRAIL _ EXTENSION F/81.1 D Q MC10 X 8.4 E/51.1 N N ea cp x x RY -WELD STEEL BAR c OR APPROVED EQUAL 12" STEEL RY -WELD r- GRATING (3/4" X 1/8" FOR STAIR TREAD 2' -6" SPAN) (10 -W -4) s BALANCE OF INFORMATION PER SECTIONS C /S1.1 bi E /S1.1 D/S1.1 1 / C/S1.1 RY -WELD STEEL BAR ---� OR APPROVED EQUAL GRATING (3/4" X 1/8" FOR 2' -6" SPAN) (10 -W -4) NEW MANDOOR & STEEL FRAME CUT OUT STAIR FRAMING PLAN F /51.1 C6 PER PLAN---' 12" STEEL RY -WELD STAIR TREAD I 1 1/2 X 1 1/2 X 3/16" X 0' -8" ANGLE TO SUPPORT STEEL STAIR TREADS MC PER PLAN F /S1.1 OPP C/S1.1 5' -0" 1 6 TREADS 0 11" • 1" GRATE OVERHANG • 5' -7" —1 1/4 11 1 (SCHED 40) VERTICAL 12" SECTION MC10 X 8.4 1 1/41 (SCHED 40) VERTS 0 5 1 /4 "o.c. MAX 1 1/4 "1 (SCHED 40) CONT HANDRAIL EA SIDE OF STAIR b LANDING 1' -6" X 1' -6" • — (12 GA) RISER PLATES (TACK WELD TO STRINGERS !A SIDE) 1/21 X 8" ANCHOR BOLTS 1/4" X 1 1/2" PLATE 1/4" X 3" PLATE (2) #4 EA WAY REVIEWED FOR — CODE COMPLIANCE APP OWED NOV 1 MO 3/4• . 1 0 N SHIEST : tii&I 0. 1 Cipn In Ell/ p� i la: g 1 DElaGN ik 10107 NH JT 11/16/10 S1.1 w U w CD CD 3 cc a. p I p 0 LT - 1 k . C 1/4" PLATE W/— (2) 1/2 "• X 3 1/2" WEDGE ANCHORS 1 1/4" DETAIL "a" (E) WOOD COL NEW 4 X 12 TOP PLATE W/ NEW SIMPSON L70 CLIPS EA SIDE ITYP) (E) DBL PLATE SECTION DETAIL "f" (E) ROOFING (E) 4 X PURLINS (E) FIRE RETARDENT VINYL SHEETING (NEW FIRE RETARDENT VINYL SHEETING O SIM CONDITION) C10 X 15.3 W/ 5/8"1 X 3 1/2" WEDGE ANCHORS 0 36 "o.c. NEW 4 X 12 TOP PLATE BETWEEN (E) COLS (E) 2 X 4 0 24 "o.c. STUD WALL W/ 1/2" PLYWOOD EA SIDE BETWEEN IEI 10 X 10 BLDG COLUMMS (NEW 2 X 4 • 24 "o.c. STUD WALL W/ 1/2" PLYWOOD EA SIDE • SIM CONDITION) (E) 1/2"1 X 4 1/2" WEDGE ANCHORS 0 24 "o.c. (NEW 1/2 "/ X 4 1/2" WEDGE ANCHORS 0 24 "o.c. • SIM CONDITION) (E) 5" SLAB ON GRADE (E) CONC WALL 3/16 SECTION NEW MANDOOR W/ STEEL FRAME CUT OUT NEW MAN DOOR 24 "/ OPENING SECTION 1 1/2" SECTION - 1 1/4"t (SCHED 'FOi' HORIZ 1 1/4"1 (SCHED 40) CONT HANDRAIL EA SIDE OF STAIR (NO HANDRAIL 0 SIM CONDITION) -1 1/4 "1 (SCHED 40) VERTICAL -1 1/4 "e (SCHED 40) HORIZ RY -WELD STEEL BAR OR APPROVED EQUAL GRATING (3/4" X 1/8" FOR 2' -6" SPAN) (10 -W -4) 3/8" X 0' -5" SQ PLATE X3X3 /16 HSS W/ (4) 1/2 "e X 3" W.H.S. GUARDRAIL PER SECTION D /S1.1 C6 PER PLAN 24 "e (2500 PSI) SONOTUBE -RY -WELD STEEL BAR OR APPROVED EQUAL GRATING (3/4" X 1/8" FOR 2' -6" SPAN) (10 -W -4) r-4X3X1/4 "XO' -6" W/ (2) 3/8 "e X 3" WEDGE ANCHORS & (2) 3/8"1 (A307) BOLTS 3' -0" EQ 1/4 VE ICAL 1 "1 (SCHED 40) VERTICAL 0 5 1 /4 "o.c. MAX 1 1/4 "e (SCHED 40) HORIZ 3.7/8" MAX CLR -C6 PER PLAN 1 1/4 "1 (SCHED 40) CONT HANDRAIL EA SIDE OF STAIR & LANDING HSS COL PER PLAN SECTION HANDRAIL _ EXTENSION F/81.1 D Q MC10 X 8.4 E/51.1 N N ea cp x x RY -WELD STEEL BAR c OR APPROVED EQUAL 12" STEEL RY -WELD r- GRATING (3/4" X 1/8" FOR STAIR TREAD 2' -6" SPAN) (10 -W -4) s BALANCE OF INFORMATION PER SECTIONS C /S1.1 bi E /S1.1 D/S1.1 1 / C/S1.1 RY -WELD STEEL BAR ---� OR APPROVED EQUAL GRATING (3/4" X 1/8" FOR 2' -6" SPAN) (10 -W -4) NEW MANDOOR & STEEL FRAME CUT OUT STAIR FRAMING PLAN F /51.1 C6 PER PLAN---' 12" STEEL RY -WELD STAIR TREAD I 1 1/2 X 1 1/2 X 3/16" X 0' -8" ANGLE TO SUPPORT STEEL STAIR TREADS MC PER PLAN F /S1.1 OPP C/S1.1 5' -0" 1 6 TREADS 0 11" • 1" GRATE OVERHANG • 5' -7" —1 1/4 11 1 (SCHED 40) VERTICAL 12" SECTION MC10 X 8.4 1 1/41 (SCHED 40) VERTS 0 5 1 /4 "o.c. MAX 1 1/4 "1 (SCHED 40) CONT HANDRAIL EA SIDE OF STAIR b LANDING 1' -6" X 1' -6" • — (12 GA) RISER PLATES (TACK WELD TO STRINGERS !A SIDE) 1/21 X 8" ANCHOR BOLTS 1/4" X 1 1/2" PLATE 1/4" X 3" PLATE (2) #4 EA WAY REVIEWED FOR — CODE COMPLIANCE APP OWED NOV 1 MO 3/4• . 1 0 N SHIEST : tii&I 0. 1 Cipn In Ell/ p� i la: g 1 DElaGN ik 10107 NH JT 11/16/10 S1.1 w U w CD CD 3 cc a.