Loading...
HomeMy WebLinkAboutPermit PG09-016 - COSTCO - DELI REMODELCOSTCO DELI REMODEL 400 COSTCO DR PG09 -016 Parcel No.: 2523049063 Address: Suite No: Tenant: Name: COSTCO DELI REMODEL Address: 400 COSTCO DR , TUKWILA WA Contact Person: Name: GARRY ROESTEL Address: PO BOX 760 , NORTH BEND WA Contractor: Name: ROESTEL'S MECHANICAL INC Address: PO BOX 760 , NORTH BEND WA Contractor License No: ROESTMI121PU Value of Plumbing /Gas Piping: Fees Collected: doc: UPC -10/06 400 COSTCO DR TUKW CityllIf Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us Owner: Name: SADE PAUL +ELEANOR Address: 585 POINT SAN PEDRO RD , SAN RAFAEL CA DESCRIPTION OF WORK: NEW PLUMBING AND GAS PIPING FOR DELI ROTISSERIE AREA $89,000.00 $532.25 Plumbing Bathtub or combination bath/shower Bidet Clothes washer, domestic Dental unit, cuspidor Dishwasher, domestic, with independent drain Drinking fountain or water cooler (per head) Food -waste grinder, commercial Floor dram Shower, single head trap Lavatory Wash fountain Receptor, indirect waste Sinks Urinals Water Closet PLUMBING /GAS PIPING PERMIT FIXTURE TYPE AND QUANTITY * *continued on next page ** Permit Number: Issue Date: Permit Expires On: Phone: Phone: 425 - 888 -6300 Phone: 425 -888 -6300 Expiration Date: 11/14/2009 PG09 -016 03/09/2009 09/05/2009 Uniform Plumbing Code Edition: 2006 International Fuel Gas Code Edition: 2006 Plumbing (cont.) 0 Building sewer and each trailer park sewer 0 0 Rain water system - per drain (inside bldg) 0 0 Water heater and /or vent 0 0 Industrial waste treatment interceptor, including 0 its trap and vent, except for kitchen type 0 grease interceptors 0 0 Repair or alteration of water piping and /or water 4 treatment equipment 0 0 Repair or alteration of drainage or vent piping 0 0 Medical gas piping system serving (1 -5) 1 inlets /outlets for a specific gas 1 4 Medical gas piping (6 +) inlets /outlets 1 8 Gas Piping 0 Gas piping outlets (0 -5) 4 0 Gas piping outlets (6 +) 0 PG09 -016 Printed: 03 -09 -2009 Permit Center Authorized Signature: doc: UPC -10/06 City ofTukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the d - I am authorized to sign and obtain this plumbing /gas piping permit. I CI (° 7 Signatur- — Date: Print Name: Permit Number: PG09 -016 Issue Date: 03/09/2009 Permit Expires On: 09/05/2009 Date: ` --0 This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. PG09 -016 Printed: 03 -09 -2009 Parcel No.: 2523049063 Address: Suite No: Tenant: • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us 400 COSTCO DR TUKW COSTCO DELI REMODEL 1: ** *PLUMBING AND GAS PIPING * ** PERMIT CONDITIONS Permit Number: Status: Applied Date: Issue Date: PG09 -016 ISSUED 02/12/2009 03/09/2009 2: No changes shall be made to applicable plans and specifications unless prior approval is obtained from the Tukwila Building Division. 3: All permits, inspection records and applicable plans shall be maintained at the job and available to the plumbing inspector. 4: All plumbing and gas piping systems shall be installed in compliance with the Uniform Plumbing Code and the Fuel Gas Code. 5: No portion of any plumbing system or gas piping shall be concealed until inspected and approved. 6: All plumbing and gas piping systems shall be tested and approved as required by the Plumbing Code and Fuel Gas Code. Tests shall be conducted in the presence of the Plumbing Inspector. It shall be the duty of the holder of the permit to make sure that the work will stand the test prescribed before giving notification that the work is ready for inspection. 7: No water, soil, or waste pipe shall be installed or permitted outside of a building or in an exterior wall unless, adequate provision is made to protect such pipe from freezing. All hot and cold water pipes installed outside the conditioned space shall be insulated to minimum R -3. 8: Plastic and copper piping running through framing members to within one (1) inch of the exposed framing shall be protected by steel nail plates not less than 18 guage. 9: Piping through concrete or masonry walls shall not be subject to any load from building construction. No plumbing piping shall be directly embedded in concrete or masonry. 10: All pipes penetrating floor /ceiling assemblies and fire - resistance rated walls or partitions shall be protected in accordance with the requirements of the building code. 11: Piping in the ground shall be laid on a firm bed for its entire length. Trenches shall be backfilled in thin layers to twelve inches above the top of the piping with clean earth, which shall not contain stones, boulders, cinderfill, frozen earth, or construction debris. 12: The issuance of a permit or approval of plans and specifications shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the Plumbing Code or Fuel Gas Code or any other ordinance of the jurisdiction. 13: ** *PUBLIC WORKS DEPARTMENT CONDITIONS * ** 14: Sewer (grease waste line) construction outside the building shall be performed under permit D08 -515. doc: Cond -10/06 * *continued on next page ** PG09 -016 Printed: 03 -09 -2009 • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us I hereby certify that I have read these conditions and will comply with them as outlined. All provisions of law and this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provision of any other work construction or the performance of work. Signature. Print Name: urf- doc: Cond -10/06 PG09 -016 Date: 3 1 Ct (v ordinances governing or local laws regulating Printed: 03 -09 -2009 Name: Company Name: Mailing Address: Company Name: Mailing Address: Company Name: Mailing Address: CITY OF TUKWILA Community Development Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://Www.ci.tukwila.wa.us PLUMBING / GAS PIPING PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. * *Please Print ** SITE LOCATION ciao Co Assessor's Tax No.: %� S2 3 0 °l d 6 "3 ( Site Address: tiao COS $ '6 Or Ile i k i U..a. (,,)4 Tenant Name: Property Owners Name: H C o VA.!. -t E L eG. no r Mailing Address: SfrS 9611Vt SaM 9"'A r6 la. San P.a*C40( C ot 1 City State Zip CONTACT PERSON - Who do we contact when your permit is ready to be issued t�Za•S-�•� rnctw( - -�t/\C n Mailing Address: P O I Z•ak Gd MjiV rX. E -Mail Address: po Cke- - 1 Lo G -( (a0-%lirA C73FS MKhan:GU(0MS Cdwl Contact Person: E -Mail Address: n Contractor Registration Number: at) YA p lmu l i U 1, l 2 'r`, f Ill L. Contact Person: E -Mail Address: -t'C, C a3o gripers/Se Di?. Contact Person: E -Mail Address: H: \Applications\Forms - Applications On Line\2009 Applications \I -2009 - Plumbing -Gas Piping Permit Application.doc Revised: 1 -2009 bh Plumbing/Gas Permit No. Tioq,-- .0 cc/ Project No. (For office use only) garN Suite Number: New Tenant: Day Telephone: City Fax Number: City Fax Number: i Floor: Yes 'O-r gSg- - 4306 State State State . No Zip PLUMBING / GAS PIPING CONTRACTOR INFORMATION 43A- is-d4T State Zip Day Telephone: $- c{1 S - 65 % - C 3 dd0 L(2S'_ & &s- - 6342\\ Expiration Date: ARCHITECT OF RECORD - All plans must be wet stamped by Architect of Record 41s Zip City Day Telephone: Fax Number: ENGINEER OF RECORD - All plans must be wet stamped by Engineer of Record REsoc Zip City Day Telephone: Fax Number: Page 1 of 2 Fixture Type: Qty Fixture Type: Qty Fixture Type: Qty Fixture Type: Qty Bathtub or combination bath/shower Bidet Clothes washer, domestic Dental unit, cuspidor Dishwasher, domestic, with independent drain Drinking fountain or water cooler (per head) Food -waste grinder, commercial Floor Drain _ Shower, single head trap Lavatory Wash fountain Receptor, indirect waste 4 Sinks Urinals Water Closet Building sewer and each trailer park sewer Rain water system — per drain (inside building) Water heater and/or vent Industrial waste treatment interceptor, including trap and vent, except for kitchen type grease interceptors Each grease trap (connected to not more than 4 fixtures - <750 gallon capacity) Grease interceptor for commercial kitchen ( >750 gallon capacity) Repair or alteration of water piping and/or water treatment equipment Repair or alteration of drainage or vent piping Medical gas piping system serving 1 -5 inlets/outlets for a specific gas Each additional medical gas inlets /outlets greater than 5 Backflow protective device other than atmospheric -type vacuum breakers 2 inch (51 mm) diameter or smaller Backflow protective device other than atmospheric -type vacuum breakers over 2 inch (51 mm) diameter Each lawn sprinkler system on any one meter including backflow protection devices Atmospheric -type vacuum breakers not included in lawn sprinkler backflow protections (1 -5) Atmospheric -type vacuum breakers not included in lawn sprinkler backflow protections over 5 Gas piping outlets ��`� - ewe. I Valuation of Project (contractor's bid price): $ pn6. Scope of Work (please provide detailed information): Rec.) QL 'Zt Qe 1.: (e6"1 i SS°r • L°. BUILDING OWNEWQR AUTHORIZED AGENT: Signature: Date Application Accepted: 1�/� a�` I V Building Use (per Intl Building Code): Occupancy (per Intl Building Code): Utility Purveyor: Water: Sewer: Indicate type of plumbing fixtures and/or gas piping outlets being installed and the quantity below: PERMIT APPLICATION NOTES - Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may grant one extension of time for an additional period not to exceed 180 days. The extension shall be requested in writing and justifiable cause demonstrated. Section 103.4.3 International Plumbing Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND 1 AM AUTHORIZED TO APPLY FOR THIS PERMIT. Date Application Expires: H:Wpplications \Forms - Applications On Line\2009 Applications \I =2009 - Plumbing -Gas Piping Permit Applicatiou.doc Revised: 1 =2009 bh Date: Print Name: l rCoe 1 �'l 724 -\ Day Telephone: 4 ES — CI do nn �__ Mailing Address: \ 7 0. gOr 'h (A) - Cf t s City State Zip Staff Initials: Page 2 of 2 Payee: ROESTELS MECHANICAL • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us TRANSACTION LIST: Type Method Descriptio Amount r1nr.• Rar.Aint -f A Payment Check 031043 .07 ACCOUNT ITEM LIST: Description PHOTOCOPIES /DUP SERVICES RECEIPT Parcel No.: 2523049063 Permit Number: PG09 -016 Address: 400 COSTCO DR TUKW Status: PENDING Suite No: Applied Date: 02/12/2009 Applicant: COSTCO DELI REMODEL Issue Date: Receipt No.: R09 -00273 Payment Amount: $.07 Initials: WER Payment Date: 02/18/2009 11:17 AM User ID: 1655 Balance: $0.00 Account Code Current Pmts 000/341.690 .07 Total: $.07 PAYMENT RECEIVED Printpd (19 -1R- 9(1(14 Receipt No.: R09 -00237 Payee: ROESTEL'S MECHANICAL INC ACCOUNT ITEM LIST: Description GAS - NONRES PLAN CHECK - NONRES PLUMBING - NONRES • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us RECEIPT Parcel No.: 2523049063 Permit Number: PG09 -016 Address: 400 COSTCO DR TUKW Status: PENDING Suite No: Applied Date: 02/12/2009 Applicant: COSTCO DELI REMODEL Issue Date: Initials: WER Payment Date: 02/12/2009 04:09 PM User ID: 1655 Balance: $0.00 TRANSACTION LIST: Type Method Descriptio Amount Payment Check 031043 532.25 Account Code Current Pmts 000.322.103.00.0 000/345.830 000.322.103.00.0 Total: $532.25 Payment Amount: $532.25 92.00 101.25 339.00 PAYMENT RECEIVED doc: Receiot -06 Printed: 02 -12 -2009 Project: 00s7 0 o DE l_t Type of Inspection: F i'� l - Pt«t 6- Address: L / 0 U N es-rt-c' v n 2• Date Called: Special Instructions: . Date Wanted: `5 aI — 69 fa p.m. Requester: Phone No: Zofo- - I,-It2t kci., Approved per applicable codes. COMMENTS: INSPECTION RECORD Retain a copy with permit PC-j b 1 INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 1- 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)43} - 3f Corrections required prior to approval. ?/'-' / 4,1co r7 $60.00 REINSPECTION'FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: Date: COMMENTS: p a . Type of Inspection; /2 * - / AI di/' " ‘44S 1) 0 , ,z c4/ A ?' 7 4' -- /24/>(5 4 ) ,t -" u.) c;c c.A-) 4 — i Special Instructions: Date Wanted: — /_ p 5 f) i2 `,,,y 6 ` u _s. — iv' Phone No: Project:] l ' 104- Type of Inspection; /2 * - / AI di/' " ‘44S Address: • yDd g37CIO 0 —. Date Called: Special Instructions: Date Wanted: — /_ p 5 t��q . p.m. Requester: Phone No: t,d y - a/4. INSPECTION RECORD Retain a copy with permit ION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 INSPE Approved per applicable codes. Corrections required prior to approval. Date: —. ❑ $6 u 0 REINSPECTION FEE RE( UIREtif. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Pro'e Ces "nd .G° 1; �),r Ty a of Ins Action: / =p, Ai t---7 / -- , ° /0/414 Address: 4/4 (1 le 0 -/)f - Date Called: Special Instructions: Date Wanted: G a.m. Requester: Phone No: ./2 - 69 -39/7 y INSPECTION RECORD Retain a copy with permit PEK NO. INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 ❑ Approved per applicable codes. Corrections required prior to approval. COMMENTS: .10 9:? 0 9 /A 7 ," A Ins Da e; $ • i s 0 REINSPECTION ' EE RE. IRED. Prior to inspection/fee must be p. at 6300 Southcenter Blv.., Suite 100. Call to schedui. 'reinspection. Receipt No.: (Date: r COMMENTS: © Type of spection; , 4/6/ % 4- �- ' , 0 a 61 ..,,, 1. I i3w t1 - la A1S — ► r� S 4 l (O+4 -- "V tom. Date Wanted: 19-- 9 - d C j a.m. p.m. 13 4) 1 4 ', Phone No ?o6 -2,5 // 2 / j6J A `ic...4 1A";.-1-t .3.-..N- \ ‘ t }c.4,0 --() 6.E w Project: / t2 ( L) / ^ s, Type of spection; , 4/6/ % 4- �- ' Address: yvd ( () Date Called: __ Special Instructions: Date Wanted: 19-- 9 - d C j a.m. p.m. Requester: Phone No ?o6 -2,5 // 2 / INSPECTION RECORD Retain a copy with permit _1_19RECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 1- 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 El Approved per applicable codes. Corrections required prior to approval. INSPECTION FEE EQUI ' ED. Pr'or to inspection, fee must be 6300 Southcenter Blv ., ui - 100 Call to schedule reinspection. Recei . No.: Date: Project: OS`CC�v ' Of°IIr Type of Inspection: G ech (rl � (iJcN I A d ess: ' 'kbb O c� - do p2 Date Called: Special Instructions: Date 3 nte C ` 0ci / . �p� Requester: Phone No: o - 8`]S - -q Z7 INSPECTION NO. INSPECTION RECORD Retain a copy with permit Pro -or Co PERMIT NO. • CITY OF TUKWILA BUILDING DIVISION is 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 1/4 4p2 .. ) , proved per applicable codes. Corrections required prior to approval. 1i COMMENTS: C /2 2/4/%/ /6VAli ( � k ° ./Y-( A y Na7c , IL) 54' m1 / l! veft I/ Inspec,Cpr: $6 p, AAA JCL .00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be Id at 6300 Southcenter Blv , Suite 100. Call to schedule reinspection. Receipt No.: Date: r6 Date: COMMENTS: ) Airs ,' -f ;,r.' ,i ��l Address: 4 0 (A1 A " C p/d ve-4 Special Instructions: Date Wanted: �a.m �Q p.m. Requester: Phone 31, I A k A ,,&S --PA - (ilrk '' PAL - l w ,- iS - � . ( st ‘ 5 f -v''-. cJ &N,-t J AJP A .Z 1 . : ice. / r t° Z 1 0 � -. $ k t ) — - - r v t vt 4-Ea tslkr s -.v_ o\ AfPrI1Je-k- .Li r� ri u , . l l . . S & " r7 k_ Z. ‘1. , 41 2s. kC 1 .S T a 6 Id 1 7.o -. ■ _ A I 1 Projects / i i e AA 6 U Type o I S M J k Address: 4 0 Date Called: Special Instructions: Date Wanted: �a.m �Q p.m. Requester: Phone 31, -'1 ,*( INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION r 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 Eli Approved per applicable codes. Date: El $60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: `Date: r 1 —oo C Corrections required prior to approval. 1 P , MU LVAN NY 03.03.09 Jennifer Marshall City of Tukwila 6300 Southcenter Blvd., Ste. #100 Tukwila, WA 98188 Re: Subject: Correction Letter #1 • • G2 D E S I G N A T WORK Tukwila, WA Costco Remodel Highway 60 and Interstate 94 Mettawa, IL 60045 Permit Application Number: PG09 -016 MulvannyG2 Project Number: 93- 0440 -20 Dear Jennifer: Please find responses to the plumbing /gas plan review of the Costco Wholesale Warehouse Remodel in Tukwila, WA below. 1. Plans shall be stamped and signed by a WA State Professional Engineer. (2) stamped and signed copies of sheet M -1 & M -2 are enclosed. 2. Provide rotisserie output information, how many chickens and /or meals per day. The average output of the rotisserie is 350 chickens per day / 2,450 per week. 3. What is the size of the existing outside grease interceptor? Please provide supporting calculations assuring that the existing grease interceptor has adequate grease handling capacity to accommodate the proposed deli /rotisserie. Please see response from the Mechanical Engineers (attached) 4. Floor sinks and floor drains in deli and rotisserie area shall tie into the grease interceptor line, refer to the attached mark -up. Please see response from the Mechanical Engineers (attached) 425.463.2000 425.463.2002 1110 112TH AVENUE NE I SUITE 500 I BELLEVUE, WA I 98004 MulvannyG2.com Tukwila, WA Costco Remodel 03.03.09 Page 2 of 2 Should you require any additional information regarding this matter, please contact me at 425.463.1585. Thank you. Sincerely, Travis Morton Project Manager TM /jm c: Ferguson Construction: Greg Williams • • h: \costco\93 \93- 0440- 20\ 02 _correspondence\204Jurisdiction \permit comments \pg09 -016 Itr #1.dco.doc March 2, 2009 1 T.E., Inc. Mulvanny G2 Architecture 1110 -112 Ave NE, #500 Bellevue, WA 98004 425 - 463 -2000 Attn: Travis Morton Re: Costco Wholesale — Tukwila, WA Deli & Rotisserie Remodel (TEI#08 -299, MA #93- 0440 -20) 830 North Riverside Drive, Suite 200 Renton, Washington 98057 Phone: 206 - 241 -2012 / FAX: 206 - 241 -3101 www.tei - engineering.com Dear Travis, The following are the Mechanical comments to the Public Works Dept.: 1. Plans shall be stamped and signed by a WA State Professional Engineer. Response: (2) copies of sheet M -1 & M -2 are enclosed. 2. Provide rotisserie output information, how many chickens and /or meals per day. Response: (By owner) 3. What is the size of the existing outside grease interceptor? Please provide supporting calculations assuring that the existing grease interceptor has adequate grease handling capacity to accommodate the proposed deli /rotisserie. Response: The supporting calculation and size of existing grease interceptor are shown on plan M -1 with cloud. 4. Floor sinks and floor drains in deli and rotisserie area shall tie into the grease interceptor line, refer to the attached mark -up. Response: The existing floor drain and one new floor sink are connected to existing waste line which connects to another existing grease interceptor at north side of building. See plan M -1 and M -2 with clouds. If you have further questions, please call our office. Sincerely, James Shen 299MBD 01:doc February 26, 2009 Garry Roestel PO Box 760 North Bend, WA 98045 • Chy of Tukwila Department of Community Development Jack Pace, Director RE: CORRECTION LETTER #1 Plumbing/Gas Piping Permit Application Number PG09 -016 Costco Deli Remodel — 400 Costco Dr Dear Mr. Roestel: This letter is to inform you of corrections that must be addressed before your plumbing /gas piping permit(s) can be approved. All correction requests from each department must be addressed at the same time and reflected on your drawings. I have enclosed comments from the Public Works Department. At this time the Building Department has no comments. Public Works Department: Joanna Spencer at 206 431 -2440 if you have questions regarding the attached memo. Please address the attached comments in an itemized format with applicable revised plans, specifications, and /or other documentation. The City requires that two (2) complete sets of revised plans, specifications and /or other documentation be resubmitted with the appropriate revision block. In order to better expedite your resubmittal, a `Revision Submittal Sheet' must accompany every resubmittal. I have enclosed one for your convenience. Corrections /revisions must be made in person and will not be accepted throu>;h the mail or by a messenger service. If you have any questions, please contact me at (206) 433 -7165. Sincerely, ifer M •• rshall it Technician e File: PG09 -016 P:\Permit Center \Correction Letters \2009\PG09 -016 Correction Letter #1.DOC jem Jim Haggerton, Mayor 6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone: 206 - 431 -3670 • Fax: 206 - 431 -3665 DATE: February 18, 2009 PERMIT NO: PG09 -016 P: joanna/comments 1 PG09 -016 PUBLIC WORKS DEPARTMENT COMMENTS PROJECT: COSTCO Deli Remodel 400 Costco Dr PLAN REVIEWER: Contact Joanna Spencer (206) 431 -2440 if you have any questions regarding the following comments. 1) Plans shall be stamped and signed by a WA State Professional Engineer. 2) Provide rotisserie output information, how many chickens and/or meals per day. 3) What is the size of the existing outside grease interceptor? Please provide supporting calculations assuring that the existing grease interceptor has adequate grease handling capacity to accommodate the proposed deli/rotisserie. 4) Floor sinks and floor drains in deli and rotisserie area shall tie into the grease interceptor line, refer to the attached mark -up. ACTIVITY NUMBER: PG09 -016 DATE: 03 -03 -09 PROJECT NAME: COSTCO DELI REMODEL SITE ADDRESS: 400 COSTCO DR Original Plan Submittal X Response to Correction Letter # 1 Response to Incomplete Letter # Revision # After Permit Issued DEPARTMENTS: -5_71 Building I Islo Public Works DETERMINATI OF COMPLETENESS: (Tues., Thurs.) Complete Comments: Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: TUES /THURS RO TING: Please Route Structural Review Required REVIEWER'S INITIALS: APPROVALS OR CORRECTIONS: Documents/routing slip.doc 2 -28 -02 ' PERMIT COORD COPY • PLAN REVIEW /ROUTING SLIP Fire Prevention Structural Incomplete n DATE: DATE: Planning Division Permit Coordinator Not Applicable No further Review Required Approved Approved with Conditions Not Approved (attach comments) n Notation: REVIEWER'S INITIALS: u DUE DATE: 03-05-09 n DUE DATE: 04 -02-09 Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: • • MIT WORD C PLAN R VIEW /ROUTING SLIP ACTIVITY NUMBER: PG09 -016 DATE: 02 -12 -09 PROJECT NAME: COSTCO DELI REMODEL SITE ADDRESS: 400 COSTCO DR X Original Plan Submittal Response to Correction Letter # Response to Incomplete Letter # Revision # After Permit Issued DEPARTMENTS: Building Division MO ublic Works Complete Please Route Documents /routing slip.doc 2 -28 -02 TUES/THURS ROUTING: APPROVALS OR CORRECTIONS: Fire Prevention Structural DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Incomplete Planning Division n Permit Coordinator DUE DATE: 02 -17 -09 Not Applicable Comments: Li n Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: Structural Review Required No further Review Required Permit Center Use Only rrn P CORRECTION LETTER MAILED: vi g t Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW Staff Initials: REVIEWER'S INITIALS: DATE: DUE DATE: 03 -17-09 Approved In Approved with Conditions U Not Approved (attach comments) L Notation: REVIEWER'S INITIALS: DATE: Date: Q3/O.3 /0Q Contact Person: Sheet Number(s): L4 -1 , Mt- 2 Entered in Permits Plus on City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206-431-3665 Web site: hrrp :Iiwww.ci.tukwila.wa.us 1 REVISION SUBMITTAL 1 Revision submittals must be submitted in person at the Permit Center. Revisions will not be accepted through the mail, fax, etc. ❑ Response to Incomplete Letter # ® Response to Correction Letter # ❑ Revision # after Permit is Issued Project Name: Costco Deli Remodel Plan Check/Permit Number: PG09 -016 CRY OF TuKWIJ A MAR 03 2009 ❑ Revision requested by a City Building Inspector or Plans Examiner PERMIT CENTER Project Address: 400 Costco Dr �R MO Phone Number: 12 5. 6"C .156'5 Summary of Revision: TIE M -1 AND At-2 bRNtALTACa'c nave t3rJN RFJTSF0 54rttl - rl REriuF6TEO Ile'•. ' :♦ CAPFtCrTY O THE 7 T PTOQ ARE' 1 w iq A5 oiFt t A5 U; RrFT.c,rrsnI 74-1, 7 'F Su UF' r;.: L1:1\17-7 . R0 OutP*C i ATrakii 1 rtr,'ro tO J 44 T CT LFITFR "Cloud" or highlight all areas of revision including date of revision Received at the City of Tukwila Permit Center by: \applications\forms- applications on line\rcvision submittal Created: 8 -13 -2004 Revised: Bond Bond Company Name Bond Account Number Effective Date Expiration Date Cancel Date Impaired Date Bond Amount Received Date 5 COLONIAL AM CAS Et SURETY OF MD LPM406621 9 05/16/2004 Until Cancelled $12,000.00 05/17 /2004 4 CBIC SA9312 11/14/2001 Until Cancelled 06/27/2004 $12,000.0011/13 /2001 3 CBIC SA9312 05/16/1997 11 /14/2001 $6,000.00 2 MARKEL INS CO 86245250 10/23/199610/23/199705/21/1997 $6,000.00 1 CBIC 655195 10/23/198810/23 /1996 $6,000.00 Name Role Effective Date Expiration Date ROESTEL, GARRY J 01/01/1980 ROESTEL, TERRY D 01/01/1980 Untitled Page Business Owner Information • General /Specialty Contractor A business registered as a construction contractor with Ls*I to perform construction work within the scope of its specialty. A General or Specialty construction Contractor must maintain a surety bond or assignment of account and carry general liability insurance. Business and Licensing Information Name Phone Address Suite /Apt. City State Zip County Business Type Parent Company ROESTEL'S MECHANICAL INC 4258886300 PO BOX 760 NORTH BEND WA 98045 KING Corporation UBI No. Status License No. License Type Effective Date Expiration Date Suspend Date Previous License Next License Associated License Specialty 1 Specialty 2 601047475 ACTIVE ROESTMI121 PU CONSTRUCTION CONTRACTOR 10/31/1988 11/14/2009 ROESTMI131 P3 STONENL940NP GENERAL UNUSED Bond Information Insurance Information https://fortress.wa.gov/lni/bbip/Detail.aspx?License=ROESTMI121PU Page 1 of 2 03/09/2009 GAS SIZE CHART PRESSURE IN WC 7 PRESSURE DROP 0.5 MAX DEVELOPED LENGTH (FEET) 100 PIPE SIZE ( UPC ) MAX LOAD (MBH) 1/2" 3/4" 47 3/4" 1" 98 1" 1 -1/4" 185 1-1/4" 1 -1 /2" 380 1-1/2" 2" 570 2" 2-1/2" 1,098 2-1/2" 3" 1,750 3" 4" 3,093 4" 6" 6,309 6" 8" 18,483 8„ 37,976 GAS SIZE CHART PRESSURE PSI 2 PRESSURE DROP PSI TO 1.0 MAX DEVELOPED LENGTH (FEET) 500 PIPE SIZE( UPC ) MAX LOAD (MBH) 1/2" 182 3/4" 380 1" 716 1 -1/4" 1,471 1 -1 /2" 2,204 2" 4,244 2-1/2" 6,764 3" 11,958 4" 24,390 6" 71,449 8" 146,801 0 rr) 0 0 ) MD 0 0 c`J 0 0 0 0 _ N 0 L_L_ 0 0 0 O 0 0 0 0 0 0 0 0 00 O 0 0 0 0 00 0 0 PLUMBING GENERAL NOTES THC FOLLOWING NOTES APPLY TO ENTIRE PLAN AS APPLICABLE. % MINI UM UNLESS OTHERWIS E NO DDfiNS` PIPIM ST C �iv1‘D l BE` 4PED - AT"` 1. ALL WASTE OTHERWISE I COT 2'- / Iq/ Co"-- L/ ` --1-€""ec v`' el #5.e a 2. SURFACE MOUNTED PIPING 1A7Z11 pikig_ AND CONDUIT OF ALL TYPES SHALL BE CONCEALED WITHIN WALLS, FLOORS, CEILINGS (INCLUDING CONDENSATE DRAIN LINES, WATER HEATER PRESSURE RELIEF LINES AND SODA LINES) 3. ALL DIMENSIONS TO COLUMN LINES. 4. INSULATE ALL INTERIOR STORM DRAIN INCLUDING OVERFLOW PIPING, HOT & COLD WATER PIPING AND CONDENSATE PIPING PER SPECIFICATION SECTION 15250. 5. MOUNT ALL OVERHEAD PIPING 6" MAXIMUM FROM BOTTOM OF JOIST OR GIRDER IN MAIN SALES AREA. DO NOT BLOCK LIGHTING & SKYLIGHTS. 6. APPLICABLE PLUMBING CODE: 2006 UPC 7. PAINT ALL METAL & PVC PIPING EXPOSED TO WEATHER PER SPEC SECTION 09900 8. COORDINATE WITH G.C. FOR INSULATION REQUIREMENTS AT EXTERIOR WALLS FOR AREAS ADJACENT TO PLUMBING LINES AREA NEW CHICKEN ROTISS. /DELI. TOTAL GREASE INTERCEPTOR CALCULATIONS FIXTURE NUMBER DFU 3 COMP SINK E -23 1 8 2 COMP SINK E -12 1 3 1 COMP SINK E -16 1 3 SKEWER (WB -1) 1 8 FLOOR DRAIN (D -1) 3 1 2 6 HAND SINK 6 TRENCH DRAIN(TD -10) 2 TOTAL DFU 8 3 3 8 3 12 16 53 USING 2006 UPC TABLE 10 -3, INTERCEPTOR WILL BE SIZED AT 1250 GALLONS. THE EXISTING GREASE INTERCPTOR IS 1500 GALLONS AND IS ADEQUATE TO USE. 17_37771 :r -r- I GAS CALCULATIONS EXISTING GAS LOAD CD 2PSI LINE 3,730,000 BTUH NEW GAS LOAD 412,000 BTUH TOTAL NEW LOAD 4,142,000 BTUH EXISTING 6" GAS LINE IS SUFFICIENT. MECHANICAL PLAN NOTES SEE 8 BBLE FOR SPECIFIC REFERENCE ON PLAN MC TO LOCATE ROOF PENETRATIONS AND ROOF CURB FOR G.C. PENETRATIONS SHALL BE SUCH THAT SUPPLY, RETURN AND /OR EXHAUST DUCT DROPS CAN EXTEND STRAIGHT DOWN TO CEILING SPACE OR DIFFUSER PACKAGE. COORDINATE EQUIPMENT LOCATION WITH LIGHTS, BLDG. STRUCTURE, PIPING, SWAY BRACING AND SKYLIGHTS. SEE ARCHITECTURAL, STRUCTURAL AND ELECTRICAL PLANS. LOCATE SALES FLOOR AC UNITS BETWEEN RACKS. REQUIRED CLEARANCE FOR ROOFTOP UNIT IS SHOWN. RELOCATION OF ANY UNIT FROM WHERE SHOWN ON PLAN SHALL BE APPROVED BY ARCHITECT PRIOR TO UNIT INSTALLATION. PIPING TO BE THRU THE BASE /CURB, ROUGH —IN PER DETAILS PRIOR TO SETTING EQUIPMENT. LOCATE ALL FLOOR CLEAN OUTS OUTSIDE OF FORKLIFT DRIVE AISLE (UNDER RACKING OR WITHIN 18" OF WALL) FOR SALES FLOOR WASTE LINES SEE 41/M-4 FOR CLEAN OUT OFFSET. RUN PIPING IN ROOF TRUSS SPACE. DO NOT RUN PIPING BELOW SKYLIGHTS OR AT AN ANGLE. PIPING TO BE PARALLEL OR PERPENDICULAR TO JOIST OR GIRDER. EXISTING GAS METER — VERIFY CAPACITY WITH PSE CONTACT CUSTOMER SERVICE © 1 -858 -321 -7779 r PLUMBING PLAN NOTES SEE BUBBLE ON PLAN FOR SPECIFIC REFERENCE. r _ 1 0 (E)3" 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 I G EXISTING GAS METER CO 2 PSI EXI TING GAS METER @ 7 "W.C. (E)4" ON ROOF (1,705 MBH) 1. M.C. SHALL ASSURE ALL ROOF TOP EQUIPMENT IS LABELED CORRECTLY AND MATCH CALLOUTS ON PLAN ON THE INSIDE & OUT OF THE BUILDING. THIS INCLUDES TRANE UNITS & EXHAUST FANS, LABELS SHOULD BE IN 6" BLOCK Lb, IIERING IN BLACK COLOR AND LOCATED WHERE EASILY VISIBLE FROM THE ROOF HATCH. 2. MAINTAIN A MINIMUM OF 10' -0" BETWEEN EXHAUST OUTLET AND UNIT FRESH AIR INTAKE. 3. COORDINATE ALL MECHANICAL DUCTWORK LOCATIONS WITH ELECTRICAL EQUIPMENT. NO DUCTWORK WILL BE ALLOWED TO RUN OVER THE TOP OF ELECTRICAL DISTRIBUTION EQUIPMENT OR PANELS. 4, INSTALLATION INSTRUCTIONS FOR ALL LISTED EQUIPMENT SHALL BE PROVIDED TO THE FIELD INSPECTOR AT TIME OF INSPECTION. 5, DIMENSIONS ARE TO COLUMN LINES. 6. APPLICABLE MECHANICAL CODE: 8008 IMC 8. RUN ALL SUPPLY, RETURN AND EXHAUST DUCTS AND FLUES BETWEEN THE ROOF AND CEILING SPACE STRAIGHT WITH INTERNAL INSULATION. NO ANGLES OR OFFSETS. CONTACT ARCHITECT TO RESOLVE ANY CONFLICTS WITH STRUCTURE. MECHANICAL GENERAL NOTES G (E)6" ON TRUSS SPACE I G G G (E) l HS 0 ( E)FCO - (E)GREASE INTERCEPTOR (15 0 GA ONS) E)SCO 1 7 r 0ffi E) J VTR L 1E1 0 1 (412 MBH) (E)GREASE INTERCEP (1250 GALLONS) ! (E "GW EXISTIN UP TO - (E)4 "GW (E)4 "GW G (E)4" ON TRUSS SPACE G G MAIN s ALE: 1 = 1 – G /02/09 r ECHANICAL PLAN 0 G ------ - - - - -- 0 - -- -4 _. _ G I - - -1 0 ( E)SCO H 0 9 (5, ° (E)2 -1/2" ON ROOF (0 MBH) - r Aj 3/02/09 0 (E)271/2" (5751 MBH) G G (E)2 -1/2" ON ROOF (775 MBH) G (E)4" ON ROOF (1,305 MBH) 1" (E) (400 (E)4" ON ROOF (1,705 MBH) (E)1 -1/2" (230 MBH) 4 — CONNECT NEW 1 "G TO EXISTING 1 -1/4" AT ATHIS POINT. CO ECT NEW 6" GW —LINE--TO 6" GW LINE APPROX. HERE. FIELD VERIFY EXACT LOCATION AND SIZE. (E)1- 1/2" (1501 MBH) \- (E)1 - 1/2" (150 MBH) (E)2" ON R (200 MBH) G G N ROOF OF r _ -- _ r .1 1 -1 /2" L - J J - 0 0 L RE DER Fe7, Woe 713 J SE pETTjIL R TISSERIETOVEN ( 03 MBH) 1" GAS DN (TYP. OF 4) r. 1 1 3/02/09 ir Permit N Plan review appro Approval of constr the violation of an of approved Field 1-1/2 „ G B y ROOF Date: FOR HVAC WORK N HIS AREA, SEE "DELI- & - - - -- ROTISSERIE HVAC SHEET M -2 FOR PLUMBING, WASTE & VENT WORK IN THIS AREA, SEE "DELI & .._ ROTISSERIE PLUMBING, - WASTE & VENT PLAN ', SHEET M -2 — L_– c it ity Of Tukwila �[ VISION X ECCANPY EXISTING TWO WATER HEATERS, 74 & 80 GALLONS, TO REMAIN P�09�ot1:49 I is subject to errors and omissions. tion documents does not authorize dopted code or ordinance. Receipt ions is acknowledged: \ _VIEWED FOR DE CO!APLIANInF APPROVED MAR 0 0 20Il9 City of Tukwila BUILDING DIyISION CORRECTION LTR# X REVISIONS No changes shall be made to the scope of work without prior approval of Tukwila Building Division. .3vis ;Lns will require a new plan submittal rf °= insiude additional plan review fees. RECEIVED MAR 0 5 7009 TUKWILA PUBLIC WORKS RECEIVED CITY OF TUKWILA MAR 0 3 2009 PERMIT CENTER 1 0 H H z U) ' w w 0 z 0 Z w L � _ � Ld w LI. 0. 01— w 0 U 0 w� 0 0 0 w Z 1- 1— 0 I — 0 ct l — z w 0 07 0 w w T 0 HVAC PLAN NOTES SEE BUBBLE ON PLAN FOR SPECIFIC REFERENCE. SEE MECHANICAL SCHEDULES TO VERIFY CONTROL TYPE, REQUIRED INTERLOCKS AND CONTRACTOR RESPONSIBILITY TO FURNISH AND /OR INSTALL. SEE SCHEDULE FOR MOUNTING HEIGHT. GENERAL NOTES THE FOLLOWING NOTES APPLY TO ENTIRE PLAN AS APPLICABLE. 1. M.C. SHALL ASSURE ALL ROOF TOP EQUIPMENT IS LABELED CORRECTLY AND MATCH CALLOUTS ON PLAN, INSIDE & OUT OF THE BUILDING. THIS INCLUDES TRANE UNITS & EXHAUST FANS. 2. MAINTAIN A MINIMUM OF 10` -0" CLEARANCE BETWEEN EXHAUST OUTLET AND UNIT FRESH AIR INTAKE. THIS CLEARANCE CAN BE REDUCED TO 5' FOR EXHAUST DISCHARGED AWAY FROM INTAKE OPENING. 3. COORDINATE ALL MECHANICAL DUCTWORK LOCATIONS WITH ELECTRICAL EQUIPMENT. NO DUCTWORK WILL BE ALLOWED TO RUN OVER THE TOP OF ELECTRICAL DISTRIBUTION EQUIPMENT OR PANEL. PER NEC REQUIREMENTS. 4. RUN ALL SUPPLY, RETURN AND EXHAUST DUCTS BETWEEN THE ROOF AND CEILING SPACE STRAIGHT WITH INTERNAL INSULATION. NO ANGLES OR OFFSETS. CONTACT ARCHITECT TO RESOLVE ANY CONFLICTS WITH STRUCTURE. S7 U CNI LC) mD 0) C 07 0 (D 0 0 (1) 0 0 0 U O 1-- -kkTrz 0 0 U U) 0 0) 0) O ( O 0) 5" 00 O O REMOVE EXIST. TRANSFER FAN AND DUCT WORK. 8/8 DUCT UP TO ROOF. SEE DETAIL ON /OFF SWITCHES 12 M-3 13 SEE DETAIL 16/16 DUC UP TO UNIT ON ROOF M-3 SCALE: 1/8" = 1' —O" III ROTISSEFjIE I111 n SCALE: 1/8" = 1' -0" F -1 EE -2 DELI & ROTISSERIE HVAC DEMO PLAN GOOSE NECK WITH 16/16 SCREENED OPENING. SEE DETAIL 7 12/12 EG91 DELI 110 CD (E)EF-1 TO REMAIN (E) MEAT PREP 2 3' ROTISSERI EXIST. EXHAUST FAN AND DUCTWORK TO I3E REMOVED, CAP CURB APPROX. HERE. E -24 DISH PREP DELI & ROTISSERIE HVAC PLAN SEE DETAIL 1 M -3 ROTISSERIE EXHAUST HOOD (SOIC) C.C. PROVIDE STAINLESS S FILLER BETWEEN HOOD AN (TYP. OF 2) 10 0 0 , EL CEILING. DEMO & CAPOFF EXIST. AIR LINE APPROX. HERE. FIELD VERIFY LOCATION. E -12 SEE DETAIL 2 —COMP SINK 3/4" H &CW DN E -1 EXISTING 2" GAS ON ROOF SEE DETAIL HAND SINK 1/2" H &CW DN (TYP. OF 2) 3/4" CW DN. TO WATER FILTER FOR COMBI OVENS. SEE 3/4" HW DN. TO OVENS SEE DETAIL TYP, OF 4. FOR CONTINUATION SEE "MAIN MECHANICAL PLAN ", SHEET M -1.1. (E) SLICING DELI. (E) CHICKEN ROTISS. 1 "(02 DELI & ROTISSERIE PLUMBING DEMO PLAN SCALE: 1/8" = 1' -0" PLUMBING PLAN NOTES C1 RUN PIPING IN ROOF TRUSS SPACE. DO NOT RUN PIPING BELOW SKYLIGHTS. DO NOT RUN AT AN ANGLE. CID SLOPE FLOOR AT 1% FOR DIAMETER OF 8' -0 ". M.C. TO ROUGH IN PLUMBING FOR 2'X2' SAW CUT AS DIMENSIONED. P—TRAP INLET TO BE MIN 24" DEEP. COORDINATE WITH REFRIGERATION CONTRACTOR TO SET DRAINS 1/2 EXPOSED FOR FINAL INSTALLATION. – ROTISSERIE PREP C_112� r E -1,) SEE DETAIL HAND SINK 1/2" H &CW DN SEE DETAIL CHICKEN PREP SINK 1/2" H &CW DN DISH PREP CONNECT NEW 3 /4 "CW, 3 /4 "HW, & 1 /2 "HWC TO EXISTING 1" CW, 1" HW, & 1 /2 "HWC APPROX. HERE. FIELD VERIFY EXACT LOCATION AND SIZE. DELI & ROTISSERIE PLUMBING PLAN CALE: 1/8" = 1'— 11 0 SEE BUBBLE ON PLAN FOR SPECIFIC REFERENCE. (E)1" CW (E)1" HW (E)1 /2" HWC { E -1 ) SEE DETAIL HAND SINK 1/2" H &CW DN REMOVE EXISTING 3 /4 "H &CW BELOW CEILING AND CAP PIPING ABOVE CEILING. E -1 ) SEE DETAIL HANG SINK 1/2" H &CW DN 3 4" 1 0� 0 GENERAL NOTES THE FOLLOWING NOTES APPLY TO ENTIRE PLAN AS APPLICABLE. ©4-16 A.F.F. © +12 A.F.F. SEE DETAIL POWERSOAK SINK W MIXING VALVE FOR DETERGENT PACKAGE 3/4" H &CW DN CAD 2 LOCATIONS PROVIDE NEW 3" VTR- AS REQUIRED FOR COMBINED WASTE & VENT SYSTEM CONNECT NEW 3" SS T EXIST. 4" SS APPROX. HERE. FIELD VERIFY EXACT LOCATION AND SIZE. SEE DETAIL ( E)4" C 1 1 1 1 1 1111111111111 —Z SEE SHEET M -1 FOR 4" WASTE TO EXISTING GREASE INTERCEPTOR (E)4" E SLICIN LELQ_,–M<_EN ROTISI I 1. SURFACE MOUNTED PIPING WILL NOT BE ACCEPTABLE. PIPING AND CONDUIT OF ALL TYPES SHALL BE CONCEALED WITHIN WALLS, FLOORS, CEILINGS (INCLUDING CONDENSATE DRAIN LINES, WATER HEATER PRESSURE RELIEF LINES AND SODA LINES). 2. INSULATE ALL INTERIOR DRAIN PIPING, HOT & COLD WATER PIPING, AND CONDENSATE PIPING PER SPECIFICATION SECTION 15250 3, PROVIDE ALL HAND SINKS WITH SYMMONS #4 -10 MIXING VALVE LOCATED BELOW SINK TO REDUCE WATER TEMPERATURE TO 110'F. 4, ALL NON —HAND SINKS ARE SERVED BY 140'F HOT WATER. POST WARNING SIGNS READING "CAUTION! 140T HOT WATER ". 5. HW STOP TO ROUGH IN ON LEFT, CW STOP TO ROUGH IN ON RIGHT. 6. ALL DIMENSIONS TO COLUMN LINES. RO (E)4" ( ISSERIE Ak T pit! M -4 FOR CONTINUATION SEE "MAIN MECHANICAL PLAN ", SHEET M -1.1. (E)3" VENT DELI & ROTISSERIE WASTE & VENT DEMO PLAN SCALE: 1/8" = 1' -0" 7. SURFACE MOUNTED PIPING WILL NOT BE ACCEPTABLE. PIPING AND CONDUIT OF ALL TYPES SHALL BE CONCEALED WITHIN WALLS, FLOORS, CEILINGS (INCLUDING CONDENSATE DRAIN LINES, WATER HEATER PRESSURE RELIEF LINES AND SODA LINES). 8. ALL VENTS ON THE COMBINATION WASTE & VENT SYSTEM SHALL BE SUPPLIED WITH WALL CLEANOUTS. 9. ALL FLOOR SINKS AND FLOOR DRAINS THAT SERVE THE COMBINATION WASTE & VENT SYSTEM SHALL BE PROVIDED WITH A P —TRAP TWO SIZES LARGER THAN THE FLOOR DRAIN OR FLOOR SINK IT IS SERVING. 10. SEE EQUIPMENT SCHEDULE FOR TRAP ARM SIZE AND VENT SIZE. 11, ALL VERTICAL OFFSETS ON COMBINATION WASTE AND VENT (CWV) TO BE AT 45` TD -20) SEE DETAIL ROTISSERIE P "EP WB -1 WALL BOX FOR SKEWER CLEANER. SEE DETAIL ( 23' -5" 3" VTR DAYLIGHT INDIRECT WASTE FROM OVEN TO TRENCH DRAIN. SEE DETAIL DELI & ROTISSERIE WASTE & VENT PLAN SCALE: 1/8' = 1' -0" CAP EXISTING WASTE LINES BELOW FLOOR. REMOVE EXISTING DRAIN AND ASSOCIATED WASTE & VENT LINES ABOVE FLOOR. KEEP 3"VENT LINE THROUGH ROOF FOR NEW VENT CONNECTION. 9' -8" 3 /O / Os REVIEWED FOR CODE COMPLIANCE APPROVED MAR 0 6 2009 City of Tukwila BUILDING DIVISION (? \ov RECEIVED CITY OF TUKWILA MAR 0 3 2009 PERMIT CENTER 0 z0 z � 0 ww w 0 LL 0 0 0 w v) 2 m2 > : 0 w o- I— 0 I_. 0 0 I LL I— `` cL 0 0 0 PLUMBING FIXTURE SCHEDULE CONTRACTOR PROVIDED SYMBOL DESCRIPTION MFR. /MODEL WASTE VENT COLD W. HOT W. SPECIFICATIONS DETAIL SERVES NOTES PRAEVEtION BACKFLOW FLOOR DRAIN STAINLESS CSDFS .COM CSDFS -R -4 10 -50.S 4" 2" . 1 -1/2" 1 -1/2" HEAVY DU'L'Y, 1/2 STAINLESS STEEL SLOTTED GRATE WITH 12 GA TYPE 304 STAINLESS STEEL BODY, ANCHOR TABS, NO -HUB OUTLET, STAINLESS STEEL SEDIMENT BASKET. DRILL AND TAP UPPER FRAME FOR TRAP PRIMER AS REQUIRED. 1/P� -4.1 MEAT, BAKERY, DELI FOOD SERVICE, ROTISSERIE (8) (13) N/A D -1� L AG S FLOOR SINK DRAIN STAINLESS DRAINS.COM CSDSINK12X12X12 1 /2PIFDS 4" 2" ARTMENT PREP.) UNIVERSAL INDIRECT SINK WASTE, 12" SQUARE EXTRA DEEP 14GA STAINLESS STEEL RECEPTOR. DOME BOTTOM STRAINER, . PERFORATED 1/2 GRATE AND INTERNAL FLANGE. 3 -4.1 MEAT, BAKERY, DELI FOOD SERVICE (13) N/A D - D 4 MEAT PREP (1) (2) FLOOR CLEAN OUT ZURN ZN- 1400 -HD SEE PLAN AJUSTABLE FLOOR CLEANOUT, DURA- COATED CAST IRON BODY, WITH GAS AND WATERTIGHT ABS TAPERED THREAD PLUG, AND HEAVY DUTY TOP WITH POLISHED NICKEL BRONZE VENEER COVER. 5/P -41 N/A CO 22/M -4 FLOOR CLEAN OUT ZURN ZN- 1400 --HD SEE PLAN E -1 FLOOR CLEAN OUT WITH HEAVY DUTY POLISHED NICKEL BRONZE TOP. COMBI OVEN AGA FOOD SERVICE N/A (_ FCO ) FFS HB-:2) HOSE BIBB WATTS SC8 -4 l� ( 2) (3) 1 4 2) LH -BS BP AV� SEE PLAN +12 ", WALL SILL, SILLCOCK WITH HAND WHEEL CH ICKEN PP E /SINK (2) H _ B L AVB S 2" 1/2" THERMOSTATIC MIXING VALVE SYMMONS SAFETYMIX- VISU -TEMP 4- 500VT- X-CHKS 13 /M -4 CHICKEN PREP 1/2" 1/2" PRESSURE- BALANCING MIXING VALVE WITH INTEGRAL THERMOMETER AND ADJUSTABLE CHECK /SERVICE STOPS. AT 3 COMP SINK - MIXING VALVE MOUNTED AT 76" A.F.F., AND TEMPERED WATER FROM MIXING VALVE AT 16" A.F.F. BELOW 3 COMP SINK AT PAN WASHER WALL- TEMPERED WATER 0+60" A.F.F. FROM NEARBY 3- COMPARTMENT SINK MIXING VALVE. 7/M -4 MEAT & BAKERY DELI (ECOlAB DISPENSER) N/A HARDT EQUIP INDIRECT TRENCH DRAIN LENGTH =5,10,20 LENGTH =15 25 STAINLESS DRAINS.COM SD6X1 SLOTTED 3" 2" DISH PREP` (1) (2) 14 GA STAINLESS STEEL BODY WITH 1/4" STAINLESS STEEL SLOTTED GRATE, PRO VIDE WITH SDSB SEDIMENT BASKET, 6" WIDE 4/M -4 MEAT PREP ROTISSERIE 8 { ) N/A (TD -25) POWER SOAK SYSTEMS INDIRECT 2 - 2" WALL BOX GUY GRAY SSWB -82170 2" 2" 64/M -4 3/4" ©38„ INSTALL WALL BOX 0 +38" ABOVE FINISHED FLOOR. WITH WATTS N9 -CD BACKFLOW PREVENTION 28/M -4 DISH PREP. L}-I S WB -1 ROTISSERIE HOOD OVEN PLUMBING FIXTURE SCHEDULE — SUPPLIED BY OWNER INSTALLED BY CONTRACTOR (SOIC) 1 NOT USED 2 ALL HOSE BIBBS TO HAVE NON - REMOVABLE BACKFLOW PREVENTION DEVICES- TAMPER PROOF VACUUM BREAKER. 3 WATER HEATERS TO HAVE RIGID CONNECTIONS & CONSTRAINTS TO RESIST SEISMIC MOTION. 4 NOT USED 5 NOT USED n NOT USED NOT USED PROVIDE TRAP PRIMER. (9) NOT USED (10) NOT USED (11) NOT USED (12) NOT USED HAZARD TYPE BACKFLOW POTENTIAL LH - LOW HAZARD HH - HIGH HAZARD BS - BACK SIPHONAGE BP - BACK PRESSURE BACKFLOW PREVENTION RPZ - REDUCED PRESSURE PRINCIPLE BACK FLOW PVB - PRESSURE VACUUM BREAKER AG AIR GAP AVB - ATMOSPHERIC VACUUM BREAKER FRESH LINE EQUIPMENT SCHEDULE ARCH. NUMBER SYMBOL DESCRIPTION MFR. /MODEL WASTE VENT COLD W. HOT W. COMMENTS DETAIL SERVES NOTES BACKFLOW EF -11,12 EXHAUST FAN HAND SINK UNIVERSAL 1 -1/2" 1 -1/2" 1/2" 1/2" BRACKET FISHER},F1Y3174 STAINLESS 3816 G005ENECK,SPOUTWALL 6/M -4 DELI & ROTISSERIE ( 1) (3) L AG S +. `I SOOT) SINK) ARTMENT PREP.) UNIVERSAL INDIRECT 2" 2 ' + 3/4" 3/4" 98" X 35--1 /2 X 43" TYPE 304 STAINLESS STEEL, WITH DRAIN BOARDS AND UNDERSHELVES, FISHER 2210 PRE -RINSE W/ ADD -A- FAUCET, AND (2) LEVER DRAIN. 9/M -4 . MEAT PREP (1) (2) LAG S Ian ROTISSERIE OVEN HARDT 1 2" / OVEN WITH HOOD, 120 MBH, CONTRACTOR SHALL INSTALL HOOD AND CONNECT PLUMBING TO OVENS USING FLEXIBLE HOSE CONNECTION. GAS LINE SHALL BE AGA APPROVED. 22/M -4 ROTISSERIE (1) (2) (4) (5) LH-- A BVJBP I3 E -1 COMBI OVEN AGA FOOD SERVICE (2)3/4" OVEN WITH HOOD, CONTRACTOR SHALL INSTALL HOOD AND CONNECT PLUMBING TO OVENS USING FLEXIBLE HOSE CONNECTION. 22/M -4 ROTISSERIE l� ( 2) (3) 1 4 2) LH -BS BP AV� ( E -14) CH ICKEN PP E /SINK UNIVERSAL INDIRECT 2" 2" 1/2" 1/2" STAINLESS STEEL, ADJ. LEGS W /8" CENTER FAUCET, LEVER WASTES. 13 /M -4 CHICKEN PREP (1) HH-BS �E -16� g4 BIN) HARDT EQUIP INDIRECT 3/4 SKEWER CLEANER WITH 3/4 DRAIN HOSE TO RISER PIPE. 120V/10, 20 AMP W/ 6 FT POWER CORD AND RESTRAINING CABLE. 28 M--4 / DISH PREP` (1) (2) LH -BS AVB (E- 19�r ' POWER SOAK SINK POWER SOAK SYSTEMS INDIRECT 2 - 2" -- 2 2" 3/4" 3/4" . SEE' POWER SOAK SINK DETAIL # 64 FOR DIMENSIONS - TYPE 304 STAINLESS STEEL WITH DRAIN BOARDS. INCLUDED (2) IPS FAUCETS #KN34-8014 -PS, (1) IPS PRE -RINSE #K53- 5500 -PS, (3) IPS ROTARY BALL DRAINS #DBN -9100. 64/M -4 MEAT & BAKERY DELI (1) (3) S AG LAG tTY CO ROTISSERIE HOOD OVEN CAPTIVEAIRE ODEL 7824ND, E.T.L. LISTED 3054804 -001 TYPE 1 HOOD WITH FILTERS & LIGHTS, 18 GA. STAINLESS STEEL CONSTRUCTION 1/M -3 ROTISSERIE (1) N/A - � E 24 (1) EQUIPMENT .FURNISHED BY THE OWNER. THE MECHANICAL CONTRACTOR SHALL ROUGH -IN PLUMBING, INSTALL AND CONNECT ALL SERVICES. ALL P- TRAPS, TAILPIECES, ESCUTCHEONS AND STOP VALVES SHALL BE FURNISHED AND INSTALLED BY MECHANICAL CONTRACTOR. (2) CONTRACTOR SHALL RECEIVE, UNCRATE SET & CONNECT. (3) PROVIDE RIGHT & LEFT SPLASH GUARDS IN MEAT PREP. ONLY. (4) EQUIPMENT SUPPLIED AND INSTALLED BY VENDOR(S.I.V.). THE MECHANICAL CONTRACTOR SHALL ROUGH-IN PLUMBING AND PROVIDE SHUTOFF VALVES AND ESCUTCHEONS. VENDOR TO MAKE ALL FINAL CONNECTIONS. (5) NOT USED HAZARD TYPE BACKFLOW POTENTIAL LH - LOW HAZARD HH - HIGH HAZARD BS - BACK SIPHONAGE BP -- BACK PRESSURE BACKFLOW PREVENTION RPZ - REDUCED PRESSURE PRINCIPLE BACK FLOW PVB - PRESSURE VACUUM BREAKER AG - AIR GAP AVB -- ATMOSPHERIC VACUUM BREAKER EXHAUST FAN /RADIANT HEATER EQUIPMENT SCHEDULE SYMBOL ITEM SERVES MFR /# PENN DX11 S DESCRIPTION 320 CFM 0 0.25' SP. 1300 NOM. RPM. CONTROLLED BY WATER PROOF 30 MINUTE TIMER SW. PROVIDED BY E.C. 2782 CFM 0 1.4 A ESP. PROVIDE WITH FLOATING HINGE. CONTROLLED BY ON /OFF SW. PROVIDED BY E.C. UL 762 LISTED ELECT. 1 /10HP 120V/10 1-1/2 HP 208V/30 WEIGHT 36# 142# REFERENCE 12/M -3 13/M --3 REMARKS 12" SQ. ROOF OPENING 20" SQ. ROOF OPENING 24 MINIMUM CURB HEIGHT NOTES (1) (2) (5) (1) (3) (4) (7) EF -7 EXHAUST FAN DELI EF -11,12 EXHAUST FAN ROTISSERIE OVENS PENN FX18BH GENERAL NOTES: ALL SWITCHES AND T -STATS MOUNTED AT 42" AFF UNLESS OTHERWISE NOTED SEE DESCRIPTION FOR RESPONSIBLE CONTRACTOR, DO NOT ADJUST SPEED CONTROLLERS BELOW 60% OF FAN MOTOR SPEED SCHEDULE NOTES (SEE COLUMN ON RIGHT FOR APPLICABILITY): (1) ROOF CURB PROVIDED BY G.G. (2) PROVIDE BACKDRAFT DAMPER. (3) ANSUL SYSTEM IS PROVIDED BY G.C. G.C. TO CONTACT APPROVED SUB - CONTRATORS FOR ANSUL SYSTEM INSTALLATION. (4) COORDINATE WITH ANSUL SYSTEM AND FIRE ALARM INSTALLER FOR INTERLOCK WITH OVEN /EXHAUST FAN. (5) NO ADJUSTMENT OF AIR FLOW REQUIRED FOR AIR BALANCING. PROVIDE ALL OTHER MEASUREMENTS PER SPECIFICATION. (6) NOT USED (7) MONITORED BY BMS, BROKEN BELT INDICATOR LIGHT IN ROTISSERIE AND FOOD SERVICE. (8) NOT USED 0 1) oa 0 i v 0 c.0 CD 0 LY 0) 0) (NI 0 0) 0) N 0) N CO 0 0 ETL LISTING — # 3054804-001 MODEL 7824ND 137 " X 78 " X 24" TYPE I WITH FILTERS & LIGHTS HOOD -18GA. STAINLESS STEEL NOTE: OBTAIN APPROVAL FROM ARCHITECT FOR OFFSETS GREATER THAN 3' OR ANGLES GREATER THAN 15' - DUCT MUST BE SLOPED AT 2% MINIMUM BACK TO HOOD, SUPPLY CLEANOUTS AT ELBOWS & EVERY 12' OF HORIZONTAL DUCT, AND CONNECTION AT EXHAUST FAN MAY REQUIRE I E ING. AIR FLOW FORMULA (PER UL LISTING): Q = 25OxL = 250(11.4 FT) = 2,854 CFM MIN. DUCTS DUCT SIZE: 16" x 16" = 1.78 SQUARE FEET NUMBER OF DUCTS: 1 STATIC PRESSURE & EXHAUST FAN EXHAUST FAN CFM: 2,854 CFM EXHAUST DUCT VELOCITY: 1,605 FPM STATIC PRESSURE: DUCTS 0.31" GREASE FILTER 0.77" 10% SF 0.11" TOTAL S.P. 1.19" MAKE—UP AI SUPPLIED FROM MAIN SALES AC UNITS. CLEARANCES HOOD OVERHANG BEYOND • EQUIPMENT: FRONT SIDES CLEARANCE 6" 6 „ DISTANCE FROM OUTSIDE EDGE OF HOOD TO SURROUNDING MATERIALS: FILTERS FILTER SIZE: 16 "X2O "= 1.73SQ. FT.(USABLE AREA) 16 "X 16 "= 1.35SQ. FT. (USABLE AREA) NUMBER OF FILTERS: 6X16 "X20 ", 1X16 "X16" TOTAL FILTER AREA: 6 X 1.73 = 10.38 SQ. FT.(USABLE AREA) 1 X 1.35 = 1.35 SQ. FT.(USABLE AREA) AIR VELOCITY: 2,854 CFM / 11.73 SQ. FT. = 243 FPM SCALE: NONE REASE TROUGH TRANSITION M=L'illinallIrlF1111111111111111111111=11=111111111101 UPBLAST TYPE EXHAUST REASE TROUGH ONE HOUR RATED FIRE WRAP ASSEMBLY BY G.C. SEE ARCH. AND STRUCTURAL DRAWINGS —AUTO MAN TANK FOR ANSUL SYSTEM. MOUNT ABOVE CEILING SUPPORT AS REQUIRED BY M.C. SEE STRUCTURAL DRAWINGS CAPTIVE -AIRE HOODS ARE BUILT IN COMPLIANCE WITH NFPA 996 NSF UL 710 & ULC710 STANDARDS E.T.L. LISTED 3054804 -001 10' -0" CEILING WALL 100W VAPOR PROOF INCANDESCENT LIGHT HANGING ANGLE MANUAL PULL STATION. COORDINATE W /FIRE WALL ALARM SYSTEM ROTISSERIE OVEN BY COSTCO FRONT ELEVATION FIELD CUT EXHAUST OPENING ALONG FRONT OF HOOD TO MINIMIZE OFFSETS IN DUCTWORK. COORDINATE WITH STRUCTURAL FRAMING INSTALLER TO RELOCATED SUPPORT JOIST TO AVOID DUCTWORK. NOTES: HOOD SHALL BE INSTALLED COMPLETE WITH FIRE SUPPRESSION SYSTEM AND SOLENOID VALVE AT FUEL LINE OF EQUIPMENT. AUTOMATIC FIRE EXTINGUISHING SYSTEM SHALL BE INTERCONNECTED TO THE FUEL SOURCE & ARRANGED TO AUTOMATICALLY SHUTOFF EQUIPMENT UNDER THE HOOD WHEN THE SYSTEM IS ACTUATED. SHUTOFF VALVES OR SWITCHES SHALL BE OF A TYPE THAT REQUIRES MANUAL OPERATION TO RESET. FIRE SUPPRESSION SYSTEM, INSTALLED BY G.C., SHALL BE CAPABLE OF SENDING AN ALARM SIGNAL TO THE MONITORING SERVICE WHEN ACTUATED. ALL SOLENOID VALVES, FUEL SHUTOFFS & EQUIPMENT INTERLOCKS AND SWITCHES SHALL BE THE RESPONSIBILITY OF THE MECHANICAL CONTRACTOR. ALL REQUIRED OFFSETS FOR FLUE AND EXHAUST DUCTS BETWEEN OVEN AND ROOF PENETRATION TO BE MADE ABOVE FINISHED CEILING. FIRE SUPPRESSION SYSTEM SHALL NOT RUN HORIZONTALLY WITHIN EXPOSED HOOD CAPTURE CAVITY. ALL ANSUL /INTERLOCKS AND ASSOCIATED WIRING (SHUNT TRIP BREAKERS OR RELAYS) ARE THE RESPONSIBILITY OF MECHANICAL CONTRACTOR. 11' -5 Rotisserie Oven Hood & Exhaust Fan Detail 9" MIN T a E E HOOD PLAN VIEW EXHAUST FAN. SEE DETAIL VENTED CURB 16x16 16 GA. BLACK STEEL. ALL SEAMS & JOINTS WELDED BY M.C. AUTOMAN TANK FOR ANSUL SYSTEM MOUNT ABOVE CEILING. 16" U.L. CLASSIFIED BAFFLE -TYPE GREASE FILTERS. SLOPED GREASE DRAIN WITH REMOVABLE CUP. ROTISSERIE OVEN END : ELEVATION m " FIELD CONNECTION- m CIO ADJACENT HOOD BIRD SCREEN FAN BASE ROOF EXHAUST FAN SCALE: NONE 1-1/2" X 1- 1 /2" X 1/8" L REFRIGERATION PANEL NOTE; MECHANICAL CONTRACTOR SHALL INSTALL EXHAUST GRILLE WITH REMOVABLE SCREWS FOR OWNER TO TAKE OFF FOR .CLEANING. CURB SEE SCHEDULE FOR PROVIDER BACK DRAFT DAMPER TITUS EXHAUST GRILLE ALUMINUM DUCT, SIZE PER PLAN REFRIGERATION BOX CEILING CENTRIFUGAL EXHAUST FAN, SEE SCHEDULE SHEET METAL EXHAUST DUCT UNLESS OTHERWISE NOTED ON PLANS DUCT THRU MEAT /DELI CEILING SCALE: NONE INSULATE EXHAUST DUCT UP THROUGH ROOF ALUMINUM DUCT, SIZE PER PLAN 1-1/2" X 1--1 /2" X 1/8" L REFRIGERATION PANEL EXHAUST GRILLE HINGE FOR FILTER ACCESS NOTE: MECHANICAL CONTRACTOR SHALL INSTALL GRILLE WITH REMOVABLE SCREWS FOR OWNER TO TAKE OFF FOR CLEANING. DISHROOM TRANSFER DUCT DETAIL MIN. 40" DISCHARGE 1/16" STAINLESS STEEL WIRE ROPE TO ALLOW FAN TO OPEN TO 90' FAN BASE PROVIDE HASP WITH COTTER PIN TO SECURE OPEN END OF HINGED FAN (TYP OF 2) SEE SCHEDULE FOR MINIMUM REQUIRED CURB HEIGHT AND SUPPLIER NOTE: GREASE TRAP, HINGE KIT, AND MINIMUM 40" DISCHARGE FROM ROOF DECK FOR UL 762 FANS ONLY. TITUS EXHAUST GRILLE INSULATE DUCT UP THROUGH CEILING 1" FILTER FRAME 1/4" PUROLATOR A5SS304 FILTER SUPPLIED BY M.C. INSULATION LOCATE INFRONT OF SINK REFRIGERATION BOX .CEILING 1/4 TURN SCREW GREASE TROUGH MATERIAL PER OTHER DETAIL EXTEND DUCT UP TO FAN INLET AND EXTERIOR BASE OF TOP CURB T . CENTRIFUGAL EXHAUST FAN, SEE SCHEDULE FLOATING HINGE VENTED CURB FOR TYPE I HOOD EXHAUST ROOF DECK ROOF' EXHAUST FAN SCALE: NONE ,, 24/48 1113101111 CONT. TYP. CFM DB DG WB MBH ESP EG RG CD RA SA CDF RGF CD FP RGFP CO VD MBS M.0 G.c HVAC LEGEND AIR DUCT - FIRST # IS SIDE SHOWN FLEXIBLE DUCT CONNECTION TURNING VA SUPPLY DUCT NE UP RETURN DUCT UP SUPPLY DUCT DOWN RETURN DUCT DOWN AIR VOLUME DAMPER CEILING DIFFUSER SQUARE TO ROUND DUCT TRANSITION FIRE DAMPER (FD) CONDENSATE DRAIN AIR CONDITIONER #1 THERMOSTAT THERMOSTAT (W /LOCKING COVER) SENSOR HUMIDISTAT CARBON DIOXIDE CONTINUATION TYPICAL CUBIC FEET PER MINUTE DRY BULB TEMPERATURE DOOR GRILLE WET BULB TEMPERATURE 1,000 BRITISH THERMAL UNITS /HR. EXTERNAL STATIC PRESSURE EXHAUST GRILLE RETURN GRILLE CEILING DIFFUSER RETURN AIR SUPPLY AIR CEILING DIFFUSER WITH FIRE DAMPER RETURN GRILLE WITH FIRE DAMPER CEILING DIFFUSER FOOD PREPARATION RETURN GRILLE FOOD PREPARATION CLEAN OUT VOLUME DAMPER METAL BUILDING SUPPLIER MECHANICAL CONTRACTOR GENERAL CONTRACTOR REVIEWED FOR CODE COMPLIANCE APPROVED MAR 0 6 2009 City of Tuicwlla BUILDING DIVISION F,C E V G DEC 152008 FER GUSON CONSTRUCTION UCTION SEATTLE, WA 98108 03 0 el CC >- cc z a, w 0 0 0 tn 0 0 0 cL zo 0 RECEIVED FEB 12 2009 PERMIT GENTTF MATERIAL CLEARANCE. FRONT . NON - COMBUSTIBLE 0" 0" SIDES NONCOMBUSTIBLE BACK 1 HOUR RATED FIRE RESISTANT 3 " TOP OPEN TO WAREHOUSE 1 A" 0 1) oa 0 i v 0 c.0 CD 0 LY 0) 0) (NI 0 0) 0) N 0) N CO 0 0 ETL LISTING — # 3054804-001 MODEL 7824ND 137 " X 78 " X 24" TYPE I WITH FILTERS & LIGHTS HOOD -18GA. STAINLESS STEEL NOTE: OBTAIN APPROVAL FROM ARCHITECT FOR OFFSETS GREATER THAN 3' OR ANGLES GREATER THAN 15' - DUCT MUST BE SLOPED AT 2% MINIMUM BACK TO HOOD, SUPPLY CLEANOUTS AT ELBOWS & EVERY 12' OF HORIZONTAL DUCT, AND CONNECTION AT EXHAUST FAN MAY REQUIRE I E ING. AIR FLOW FORMULA (PER UL LISTING): Q = 25OxL = 250(11.4 FT) = 2,854 CFM MIN. DUCTS DUCT SIZE: 16" x 16" = 1.78 SQUARE FEET NUMBER OF DUCTS: 1 STATIC PRESSURE & EXHAUST FAN EXHAUST FAN CFM: 2,854 CFM EXHAUST DUCT VELOCITY: 1,605 FPM STATIC PRESSURE: DUCTS 0.31" GREASE FILTER 0.77" 10% SF 0.11" TOTAL S.P. 1.19" MAKE—UP AI SUPPLIED FROM MAIN SALES AC UNITS. CLEARANCES HOOD OVERHANG BEYOND • EQUIPMENT: FRONT SIDES CLEARANCE 6" 6 „ DISTANCE FROM OUTSIDE EDGE OF HOOD TO SURROUNDING MATERIALS: FILTERS FILTER SIZE: 16 "X2O "= 1.73SQ. FT.(USABLE AREA) 16 "X 16 "= 1.35SQ. FT. (USABLE AREA) NUMBER OF FILTERS: 6X16 "X20 ", 1X16 "X16" TOTAL FILTER AREA: 6 X 1.73 = 10.38 SQ. FT.(USABLE AREA) 1 X 1.35 = 1.35 SQ. FT.(USABLE AREA) AIR VELOCITY: 2,854 CFM / 11.73 SQ. FT. = 243 FPM SCALE: NONE REASE TROUGH TRANSITION M=L'illinallIrlF1111111111111111111111=11=111111111101 UPBLAST TYPE EXHAUST REASE TROUGH ONE HOUR RATED FIRE WRAP ASSEMBLY BY G.C. SEE ARCH. AND STRUCTURAL DRAWINGS —AUTO MAN TANK FOR ANSUL SYSTEM. MOUNT ABOVE CEILING SUPPORT AS REQUIRED BY M.C. SEE STRUCTURAL DRAWINGS CAPTIVE -AIRE HOODS ARE BUILT IN COMPLIANCE WITH NFPA 996 NSF UL 710 & ULC710 STANDARDS E.T.L. LISTED 3054804 -001 10' -0" CEILING WALL 100W VAPOR PROOF INCANDESCENT LIGHT HANGING ANGLE MANUAL PULL STATION. COORDINATE W /FIRE WALL ALARM SYSTEM ROTISSERIE OVEN BY COSTCO FRONT ELEVATION FIELD CUT EXHAUST OPENING ALONG FRONT OF HOOD TO MINIMIZE OFFSETS IN DUCTWORK. COORDINATE WITH STRUCTURAL FRAMING INSTALLER TO RELOCATED SUPPORT JOIST TO AVOID DUCTWORK. NOTES: HOOD SHALL BE INSTALLED COMPLETE WITH FIRE SUPPRESSION SYSTEM AND SOLENOID VALVE AT FUEL LINE OF EQUIPMENT. AUTOMATIC FIRE EXTINGUISHING SYSTEM SHALL BE INTERCONNECTED TO THE FUEL SOURCE & ARRANGED TO AUTOMATICALLY SHUTOFF EQUIPMENT UNDER THE HOOD WHEN THE SYSTEM IS ACTUATED. SHUTOFF VALVES OR SWITCHES SHALL BE OF A TYPE THAT REQUIRES MANUAL OPERATION TO RESET. FIRE SUPPRESSION SYSTEM, INSTALLED BY G.C., SHALL BE CAPABLE OF SENDING AN ALARM SIGNAL TO THE MONITORING SERVICE WHEN ACTUATED. ALL SOLENOID VALVES, FUEL SHUTOFFS & EQUIPMENT INTERLOCKS AND SWITCHES SHALL BE THE RESPONSIBILITY OF THE MECHANICAL CONTRACTOR. ALL REQUIRED OFFSETS FOR FLUE AND EXHAUST DUCTS BETWEEN OVEN AND ROOF PENETRATION TO BE MADE ABOVE FINISHED CEILING. FIRE SUPPRESSION SYSTEM SHALL NOT RUN HORIZONTALLY WITHIN EXPOSED HOOD CAPTURE CAVITY. ALL ANSUL /INTERLOCKS AND ASSOCIATED WIRING (SHUNT TRIP BREAKERS OR RELAYS) ARE THE RESPONSIBILITY OF MECHANICAL CONTRACTOR. 11' -5 Rotisserie Oven Hood & Exhaust Fan Detail 9" MIN T a E E HOOD PLAN VIEW EXHAUST FAN. SEE DETAIL VENTED CURB 16x16 16 GA. BLACK STEEL. ALL SEAMS & JOINTS WELDED BY M.C. AUTOMAN TANK FOR ANSUL SYSTEM MOUNT ABOVE CEILING. 16" U.L. CLASSIFIED BAFFLE -TYPE GREASE FILTERS. SLOPED GREASE DRAIN WITH REMOVABLE CUP. ROTISSERIE OVEN END : ELEVATION m " FIELD CONNECTION- m CIO ADJACENT HOOD BIRD SCREEN FAN BASE ROOF EXHAUST FAN SCALE: NONE 1-1/2" X 1- 1 /2" X 1/8" L REFRIGERATION PANEL NOTE; MECHANICAL CONTRACTOR SHALL INSTALL EXHAUST GRILLE WITH REMOVABLE SCREWS FOR OWNER TO TAKE OFF FOR .CLEANING. CURB SEE SCHEDULE FOR PROVIDER BACK DRAFT DAMPER TITUS EXHAUST GRILLE ALUMINUM DUCT, SIZE PER PLAN REFRIGERATION BOX CEILING CENTRIFUGAL EXHAUST FAN, SEE SCHEDULE SHEET METAL EXHAUST DUCT UNLESS OTHERWISE NOTED ON PLANS DUCT THRU MEAT /DELI CEILING SCALE: NONE INSULATE EXHAUST DUCT UP THROUGH ROOF ALUMINUM DUCT, SIZE PER PLAN 1-1/2" X 1--1 /2" X 1/8" L REFRIGERATION PANEL EXHAUST GRILLE HINGE FOR FILTER ACCESS NOTE: MECHANICAL CONTRACTOR SHALL INSTALL GRILLE WITH REMOVABLE SCREWS FOR OWNER TO TAKE OFF FOR CLEANING. DISHROOM TRANSFER DUCT DETAIL MIN. 40" DISCHARGE 1/16" STAINLESS STEEL WIRE ROPE TO ALLOW FAN TO OPEN TO 90' FAN BASE PROVIDE HASP WITH COTTER PIN TO SECURE OPEN END OF HINGED FAN (TYP OF 2) SEE SCHEDULE FOR MINIMUM REQUIRED CURB HEIGHT AND SUPPLIER NOTE: GREASE TRAP, HINGE KIT, AND MINIMUM 40" DISCHARGE FROM ROOF DECK FOR UL 762 FANS ONLY. TITUS EXHAUST GRILLE INSULATE DUCT UP THROUGH CEILING 1" FILTER FRAME 1/4" PUROLATOR A5SS304 FILTER SUPPLIED BY M.C. INSULATION LOCATE INFRONT OF SINK REFRIGERATION BOX .CEILING 1/4 TURN SCREW GREASE TROUGH MATERIAL PER OTHER DETAIL EXTEND DUCT UP TO FAN INLET AND EXTERIOR BASE OF TOP CURB T . CENTRIFUGAL EXHAUST FAN, SEE SCHEDULE FLOATING HINGE VENTED CURB FOR TYPE I HOOD EXHAUST ROOF DECK ROOF' EXHAUST FAN SCALE: NONE ,, 24/48 1113101111 CONT. TYP. CFM DB DG WB MBH ESP EG RG CD RA SA CDF RGF CD FP RGFP CO VD MBS M.0 G.c HVAC LEGEND AIR DUCT - FIRST # IS SIDE SHOWN FLEXIBLE DUCT CONNECTION TURNING VA SUPPLY DUCT NE UP RETURN DUCT UP SUPPLY DUCT DOWN RETURN DUCT DOWN AIR VOLUME DAMPER CEILING DIFFUSER SQUARE TO ROUND DUCT TRANSITION FIRE DAMPER (FD) CONDENSATE DRAIN AIR CONDITIONER #1 THERMOSTAT THERMOSTAT (W /LOCKING COVER) SENSOR HUMIDISTAT CARBON DIOXIDE CONTINUATION TYPICAL CUBIC FEET PER MINUTE DRY BULB TEMPERATURE DOOR GRILLE WET BULB TEMPERATURE 1,000 BRITISH THERMAL UNITS /HR. EXTERNAL STATIC PRESSURE EXHAUST GRILLE RETURN GRILLE CEILING DIFFUSER RETURN AIR SUPPLY AIR CEILING DIFFUSER WITH FIRE DAMPER RETURN GRILLE WITH FIRE DAMPER CEILING DIFFUSER FOOD PREPARATION RETURN GRILLE FOOD PREPARATION CLEAN OUT VOLUME DAMPER METAL BUILDING SUPPLIER MECHANICAL CONTRACTOR GENERAL CONTRACTOR REVIEWED FOR CODE COMPLIANCE APPROVED MAR 0 6 2009 City of Tuicwlla BUILDING DIVISION F,C E V G DEC 152008 FER GUSON CONSTRUCTION UCTION SEATTLE, WA 98108 03 0 el CC >- cc z a, w 0 0 0 tn 0 0 0 cL zo 0 RECEIVED FEB 12 2009 PERMIT GENTTF REF. DRAIN SIZE ® D -3 D -4 2" 4" D -7 2" g D-3 3 D -4 4" D -7 3" 0 v v 0 SLOPE FLOOR 1% FOR A DIAM. OF 8' -0 ". TRAP PRIMER CONNECTION 3" OUTLET 3" P -TRAP INCREASE P -TRAP & TRAP ARM TO 4" WHEN CONNECTED TO CWV. FLOOR DRAIN TYPE D-1 SCALE: NONE 36" 1/2" 2X4 BLOCKING IN WALL HAND SINK E -1, F-4 SCALE: NONE OFFSET TO TRENCH DRAIN SCALE NONE PLAN VIEW PIPING WITHIN WALL SIDE ELEVATION SINK FURNISHED WITH: GOOSENECK SPOUT KNEE OR FOOT VALVES 1-1/2" WASTE TAILPIECE WALL BRACKET OR PEDESTAL PLUMBING ROUGH IN: 0 1 /2 "HW WALL STOP 0 +16" B® 1 /2 "CW WALL STOP 0 +16" C® 1-1/2" WASTE 0 20" ®D MC TO PROVIDE SYMMONS 4 -10 MIXING VALVE TO REDUCE WATER TEMPERATURE TO 110 F ON ALL HAND SINKS LOCATED IN THE DELI, MEAT, ROTISS AND BAKERY CEILING ROTISS OVENS LEVER WASTES PLUMBING ROUGH IN: O 1/2" HW WALL STOP 0 +16" ® 1/2" CW WALL STOP 0 +16" ®C w/ OR W/0 DRAIN BOARD(SEE PLAN) 0 1/2" TEMPERED WATER HB-2 0 +16" FOR DETERGENT PKG. 0 VISU -TEMP MIXING VALVE +76" FLOOR TRENCH DRAIN SEE PLAN FOR LOCATION SINK FURNISHED WITH: ELEVATION ELEVATION CHICKEN PREP SINK E-16 SCALE: NONE NOTE: OVEN DRAIN PIPE AND VENTING SUPPLIED AND INSTALLED BY OVEN VENDOR. M.C. TO PROVIDE OFFSET TO INDIRECT WASTE AS REQUIRED COORDINATE WITH OVEN INSTALLER OVEN INDIRECT WASTE CONNECTION CONCRETE FLOOR TOPPING PER ARCH. DWG'S FIN. FLOOR P TRAP & TRAP ARM M.0 TO PROVIDE WARNING SIGN ABOVE SPLASHGUARD READING "CAUTION! 140T HOT WATER" FINISH FLOOR DISPLAY CASE LOOR SINK HALF EXPOSED 24" MIN FOR DRAINS REQUIRING BLOCK OUT SEE PLAN FOR LOCATION OUTLET SIZE® ELEVATION 1 FLOOR SINK D-3 D-- 4, D-7 SCALE: NONE -- dililll FLOOR SINK ' r FINISHED FLOOR PROVIDE 1" MIN. AIR GAP O . • e , ' ■Ir RIM SET FLUSH PROVIDE OFFSET AS REQUIRED TO LOCATE DRAIN 1/2 EXPOSED COORDINATE WITH REFRIGERATION CONTRACTOR FOR FINAL LOCATION TRAP & ARM SIZE B® CAST IRON LONG SWEEP 1/4 BEND OR CAST IRON COMB, "Y" & 1/8 BEND. DIRECTION OF FLOW INTERIOR FLOOR CLEANOUT COUNTER FLASHING SLEEVE VENT THRU ROOF WALL SCALE: NONE 1' -2" 2' -2" 1' -2" 9 " ` SCALE: NONE MECHANICAL GAS SHUTOFF VALVE ACTUATED BY ANSUL SYSTEM VALVE LOCATED ABOVE CEILING IN ACCESSIBLE LOCATION ABOVE COOLER BOX. (TYP. OF 2) GAS & WATER SIZED PER PLAN CONCEALED IN WALL \ 1 - — —.DIRT LEG F". v FLEXIBLE GAS LINE (TYP.) FLEXIBLE WATER LINE (TYP,) SIDE ELEVATION ROTISSERIE OVEN PIPING DETAIL 1/8 C.I. BEND LONG SWEEPS\ ELBOW TO EXTEND UP TO FINISHED FLOOR — 45' SANITARY 'Y' TO OFFSET CLEANOUT LOCATION OUT OF DRIVE AISLES FLEXIBLE NEOPRENE FLASHING SLEEVE BY ROOFING CONTRACTOR VENT THRU ROOF 3/4" CW N.O.: NORMALLY OPEN VALVE TO PROVIDE CW TO COMBI OVEN, BUT WILL BE CLOSED IF ROTISSERIE OVEN IS INSTALLED. N.C.: NORMALLY • CLOSED VALVE BUT WILL BE OPEN IF ROTISSERIE OVEN IS INSTALLED. CLEANOUT COVER REQUIRED TO BE HEAVY DUTY CAST IRON WITH NICKEL VENEER TOP - CLEAN POLISH AFTER INSTALLATION NOTE: DO NOT LOCATE FCO IN AISLES OFFSET CLEANOUS AS REQUIRED CLEANOUTS MAY BE LOCATED: - BELOW RACKS -TO EXIT DOOR PATH - WITHIN 18" OF REFRIGERATED CASE OR EXTERIOR WALL 6" MIN (EXISTING 2 7 "WC) 3/4" HW CEILING -- -' WALL FLOOR SANITARY SEWER MAIN ON SALE FLOOR. COORDINATE LOCATION TO AVOID STRUCTURAL FOOTINGS AND 45' CONE BELOW FOOTING SALES FLOOR CLEAN OUT OFFSET DETAIL SCALE: NONE N,O. ohl . C. DAYLIGHT DRAIN LINE TO TRENCH DRAIN 3/4" CW TO EACH OVEN CONCEALED IN WALL (TYP OF 2) 3/4" CW _ P1 COMBI OVENS 1 3/4" CW SCALE: NONE SINK FURNISHED WITH: FAUCET LEVER WASTES PLUMBING ROUGH IN: 3/4" HW WALL STOP 0 +16" e 3/4" CW WALL STOP 0 +16" (Q DRAIN BOARD (E -12 ONLY) SCALE: NONE a F 1/2" H &CW BEHIND BACKSPLASH BY M.C. PLAN 1 ELEVATION FLOOR SINK TWO COMP. TSINK E-12 PROVIDE INDIVIDUA PRV FOR EACH OVEN SCREENED 180' VENT ABOVE ROOF (TYP.) PLAN VIEW M.0 TO PROVIDE WARNING SIGN READING "CAUTION! 140'F HOT WATER" INDIRECT DRAIN POWER SOAK SINK SCALE: NONE FLOOR SINK PROVIDE BACKFLOW PREVENTION AT WATER CONNECTION PER SCHEDULE (TYP.) CLEANOUT COVER REQUIRED TO BE HEAVY DUTY CAST IRON WITH NICKEL VENEER TOP M.0 TO PROVIDE WARNING SIGN ABOVE SPLASHGUARD READING "CAUTION! 140'F HOT WATER" WASTE MANIFOLD BY CONTRACTOR • • 4 3/4" HW 1 N f iQ DETERGENT PKG. BY OTHERS FLOOR SINK E LEVATION VIEW 3 CAST IRON EXTENSION SAME SIZE AS SEWER UP TO 4" DIAMETER N BUILDING DRAIN SIZE PER PLANS to (NEW 1 "@ 2PSI) SHUT OFF ROTATE VALVE TOWARD CONNECTION ON OVEN. FIELD VERIFY LOCATION OF OVEN CONNECTION. (TYP.) ROTISSERIE OVENS (TYP. OF 3) SINK FURNISHED WITH: - FAUCETS - LEVER WASTES PLUMBING ROUGH IN: ®A 3/4" HW WALL STOP 0+10" 3/4" CW WALL STOP 0 +10" 0 VISU -TEMP MIXING VALVE 0 +72" O HB -2 +16" A.F.F. FOR DETERGENT PACKAGE 0 RUN 2" W. TO FLOOR SINK O MANIFOLD 2" WASTE DAYLIGHT TO FLOOR SINK SURFACE MOUNTED HOSE BY VENDOR —RIGHT WALL 1/2" HW TO EACH OVEN CONCEALED IN WALL (TYP OF 6) 1" GAS STUBBED OUT OF WALL (TYP OF 8) DIRT LEG WASTE MANIFOLD BY CONTRACTOR - TYP. 2. PROVIDE 1" MIN. AIR GAP (TYP.) 5' Fl OWE* 89008 5' 89008 5' SCALE: NONE MEAT PREP MEI P55325 © 144" ® 37" • N/A I' 12" ®J N/A 0 60" O 24" 0 24" O 22" O N/A O 20,E O 47" 1 8 " 6 0 . DIMENSIONS g F LOW FLO , 89008 1 fir/ 89008 1 w -DB 1 7.88 /TA BOTTOM OUTLET 3" NO -HUB 5' 89008 15' / 5' 4` 5' .r 5' ! END CAP 1:1> _ _. A c= FL OW ('IYP• OF 2) *� 4, 5' 5' (TD -1 o FLOW END CAP 89008 89008 (TYP OF 2) INV 8 INV.= w/ -DB IN ' 88 BOTTOM OUTLET 3" NO-HUB END CAP {{�� (TYP. OF 2) I NV. 69 FLOW INV.= 8.50 w/ -08 7.88 BOTTOM OUTLET 3" NO -HUB 20' W/ -DB IRV BOTTOM OUTLET 3" NO -HUB FRONT ELEVATION SKEWER CLEANER 25' FLOW 89008 w/ -DB / 1 88 80TT M OUTLET 3" NO --HUB Z -890 X— SECTION DISH PREP METCRAFT PS5132 166" 37 12" 24" 12" 66" 20" 24" 30" 24" 20" 55" W/ -RFS -OI. GASKETS WII 1 ADR APPROX. 1/8" PER 401NT TO LENGTH OF ENTI8E RUN 7 " 5 -1/2 4 " 3" TRENCH DRAIN TD-5 10 15, 20 & 25 SCALE: NONE 3/4" HW M.0 TO PROVIDE WARNING SIGN READING "CAUTION! 140'F HOT WATER" PROVIDE BACKFLOW PREVENTION ON WATER SUPPLY PER SCHEDULE (TD -1 INV.= 8.50 4" MIN. 5' a sto w 5' 89008 1 89007 5 ' 4' FLOW 89008 (TD -20 788 END CAP (NP. OF 2) INV.= 20" GRATE I GRATE REFERENCE CUTTING GRATE IS NOT NECESSARY REMOVE (1) SECTION IN ROTISSERIE AREA TO ALLOW CLEAR SPACE FOR OVENS TO DRAIN. ITOP ELEVATION INVERT VIEW SECTION 4" MIN. TRAP & ARM WALL / CEILING SK- OGMA15 -12 SK- O8MA15-13 (TD -25 t INV.= 7.25 END CAP (TYP. OF 2) DRAIN HOOK 4" MIN ABOVE TOP OF UNIT SIDE ELEV ATION 38" A.F.F. REVIEWED FOR CODE COMPLIANCE APPROVED MAR 0 6 2U09 City of Tukwila BUILDING DIVISION Q E 11 DEC 1 5 2008 FERGUSON U .;; I'I.yUCTI ©N SEATTLE, WA 98108 w 0 00 0 0 N C? 3 ZLd 6 LL U 0 D 033 a w 0 FTC- 8 5 rn 0 one z o 0 g c3 E° CV 0 in I rn ; p oci) c‘,/ 14 co x co I telEIVED FEB 12 2000 PERMIT CENTER