HomeMy WebLinkAboutPermit PG09-019 - HEATHERWOOD APARTMENTSHEATHERWOOD APTS 5841 S 152 ST PGO9-019 Parcel No.: Address: Suite No: Tenant: Name: Address: doc: UPC -10/06 1157200380 5841 S 152 ST TUKW Contact Person: Name: RORY MACIASKYK Address: 211 185 PL SW , BOTHELL WA DESCRIPTION OF WORK: REPLACE 16 WATER HEATERS IN BUILDING 'D'. Value of Plumbing /Gas Piping: Fees Collected: Plumbing Bathtub or combination bath/shower Bidet Clothes washer, domestic Dental unit, cuspidor Dishwasher, domestic, with independent drain Drinking fountain or water cooler (per head) Food -waste grinder, commercial Floor drain Shower, single head trap Lavatory Wash fountain Receptor, indirect waste Sinks Urinals Water Closet Citylf Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us HEATHERWOOD APARTMENTS 5841 S 152 ST , TUKWILA WA Owner: Name: TUKWILA REALTY LLC Address: C/O SUHRCO RESIDENTIAL , 2010 156TH AVE NE STE 100 Contractor: Name: EMERALD CITY PLUMBING INC Address: 211 185 PL SW , BOTHELL WA Contractor License No: EMERACP964DJ $16,000.00 $300.00 FIXTURE TYPE AND OUANTITY * *continued on next page ** PLUMBING /GAS PIPING PERMIT Permit Number: Issue Date: Permit Expires On: Phone: Phone: 425 - 776 -3344 Phone: 425 -776 -3344 Expiration Date: 03/08/201D PG09 -019 02/19/2009 Uniform Plumbing Code Edition: 2006 International Fuel Gas Code Edition: 2006 Plumbing (cont.) 0 Building sewer and each trailer park sewer 0 0 Rain water system - per drain (inside bldg) 0 0 Water heater and /or vent 16 0 Industrial waste treatment interceptor, including 0 its trap and vent, except for kitchen type 0 grease interceptors 0 0 Repair or alteration of water piping and /or water 0 treatment equipment 0 0 Repair or alteration of drainage or vent piping 0 0 Medical gas piping system serving (1 -5) 0 inlets /outlets for a specific gas 0 0 Medical gas piping (6 +) inlets /outlets 0 0 Gas Piping 0 Gas piping outlets (0 -5) 0 0 Gas piping outlets (6 +) 0 PG09 -019 Printed: 02 -19 -2009 Permit Center Authorized Signature: Signature Print Name/ 1 L • 111. doc: UPC -10/06 City ofTukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us Permit Number: PG09 -019 Issue Date: 02/19/2009 Permit Expires On: yrawioi Date: 2- i 9 9 1 I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of wor • . I am authorized to sign and obtain this plumbing /gas piping permit. / /9 C� Dat // l 4 / Ski _11/ This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. PG09 -019 Printed: 02 -19 -2009 Parcel No.: 1157200380 Address: 5841 S 152 ST TUKW Suite No: Tenant: doc: Cond -10/06 • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us HEATHERWOOD APARTMENTS 1: ** *PLUMBING AND GAS PIPING * ** PERMIT CONDITIONS * *continued on next page ** Permit Number: Status: Applied Date: Issue Date: PG09 -019 ISSUED 02/19/2009 02/19/2009 2: No changes shall be made to applicable plans and specifications unless prior approval is obtained from the Tukwila Building Division. 3: All permits, inspection records and applicable plans shall be maintained at the job and available to the plumbing inspector. 4: All plumbing and gas piping systems shall be installed in compliance with the Uniform Plumbing Code and the Fuel Gas Code. 5: No portion of any plumbing system or gas piping shall be concealed until inspected and approved. 6: All plumbing and gas piping systems shall be tested and approved as required by the Plumbing Code and Fuel Gas Code. Tests shall be conducted in the presence of the Plumbing Inspector. It shall be the duty of the holder of the permit to make sure that the work will stand the test prescribed before giving notification that the work is ready for inspection. 7: No water, soil, or waste pipe shall be installed or permitted outside of a building or in an exterior wall unless, adequate provision is made to protect such pipe from freezing. All hot and cold water pipes installed outside the conditioned space shall be insulated to minimum R -3. 8: Plastic and copper piping running through framing members to within one (1) inch of the exposed framing shall be protected by steel nail plates not less than 18 guage. 9: Piping through concrete or masonry walls shall not be subject to any load from building construction. No plumbing piping shall be directly embedded in concrete or masonry. 10: All pipes penetrating floor /ceiling assemblies and fire - resistance rated walls or partitions shall be protected in accordance with the requirements of the building code. 11: Piping in the ground shall be laid on a firm bed for its entire length. Trenches shall be backfilled in thin layers to twelve inches above the top of the piping with clean earth, which shall not contain stones, boulders, cinderfill, frozen earth, or construction debris. 12: The issuance of a permit or approval of plans and specifications shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the Plumbing Code or Fuel Gas Code or any other ordinance of the jurisdiction. PG09 -019 Printed: 02 -19 -2009 • • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us I hereby certify that I have read these conditions and will comply with them as outlined. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provision of any other work or local laws regulating construction or the performance of work. Signature: Print Name: doc. Cond -10106 t(AA)N ti�aSL Aivut Mat u Date: PG09 -019 Printed: 02 -19 -2009 E -Mail Address: Contact Person: E -Mail Address: CITY OF TUKWILA Community Development Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www.ci.tukwila.wa.us PLUMBING / GAS PIPING PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. * *Please Print ** SITE ;LOCATION King Co Assessor's Tax No.: / / 57 ? Qt ) Site Address: ` V 2' 1 I CO _. �� Suite Number 3A t Floor: Tenant Name: Property Owners Name: Mailing Address:J g I S , 2 Company Name: ex-2;0A C{ Mailing Address: p9 1 ( 1 X �� Contractor Registration Number: 0 C e & 4 r� (For office use on 1y) New Tenant: ❑ Yes O-No a X 17 R14 T i11 City State Zip 6(/(-) ig fate Zip Day Telephone: 4-. Fax Number: CONTACT PERSON - Who do we contact when your permit is ready to be issued (C Name: I� A A aac_ t 5 l y Da Telephone: Z.C�(o -- i F — CD1 (C� g Mailin Add I( ` $ S'J t bO� City 7 State / Zip h /G_ Fax Number: '42J "77 1� Expiration Date: / �V ARCHITECT OF RECORD 4 All plans must be wet stamped by Architect of Reord. Company Name: Mailing Address: City Contact Per : Day Telephone: E- . Address: Fax Number: ENGINEER OF RECORD - All plans must be wet stamped by Engineer of Record Company Name: Mailing Address: City Contact Pers. . Day Telephone: E- - Address: Fax Number: H:\Applications\Fonns- Applications On Line\2009 Applications \I -2009 - Plumbing -Gas Piping Permit Application.doc Revised: 1.2009 bh State State Zip Zip Page 1 of 2 A Fixture Type: Qty Fixture Type: Qty Fixture Type: Qty Fixture Type: Qty Bathtub or combination bath/shower Bidet Clothes washer, domestic Dental unit, cuspidor Dishwasher, domestic, with independent drain Drinking fountain or water cooler (per head) Food -waste grinder, commercial Floor Drain Shower, single head trap Lavatory Wash fountain Receptor, indirect waste Sinks Urinals Water Closet Building sewer and each trailer park sewer Rain water system – per drain (inside building) — `fir / % Water heater and/or vent 1 W e e /, / ( / r J /1 Industrial waste treatment interceptor, including trap and vent, except for kitchen type grease interceptors Each grease trap (connected to not more than 4 fixtures - <750 gallon capacity) �j Grease interceptor for commercial kitchen ( >750 gallon capacity) Repair or alteration of water piping and/or water treatment equipment Repair or alteration of drainage or vent piping Medical gas piping system serving 1 -5 inlets/outlets for a specific gas Each additional medical gas inlets /outlets greater than 5 Backflow protective device other than atmospheric -type vacuum breakers 2 inch (51 mm) diameter or smaller Backflow protective device other than atmospheric -type vacuum breakers over 2 inch (51 mm) diameter Each lawn sprinkler system on any one meter including backflow protection devices Atmospheric -type vacuum breakers not included in lawn sprinkler backflow protections (1 -5) Atmospheric -type vacuum breakers not included in lawn sprinkler backflow protections over 5 Gas piping outlets Valuation of Project (contractor's bid price): $ (y / t/ v° Scope of Work (please provide detailed information): Building Use (per Int'l Building Code): Occupancy (per Int'I Building Code): Utility Purveyor: Water: Indicate type of plumbing fixtures and /or gas piping outlets being installed and the quantity below: PERMIT APPLICATION NOTES - Value of Construction – In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review – Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may grant one extension of time for an additional period not to exceed 180 days. The extension shall be requested in writing and justifiable cause demonstrated. Section 103.4.3 International Plumbing Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWN OR A, THORIZ GENT: ..44 Signature / i4C/1 a( Print Name: L i ( Address: 0 ,?/ H:1Appliwtionfforms•Apphcations On Line 2009 Applications1l -'009 • Plumbing -Gas Piping Permit Appli cation doe Revised 1.2009 bh ,. Sewer: Day Telephone: City Date: o2 /0 ` 0 7 T?s LJ/ 9' Di State Zip Date Application Accepted: 1 q -- 0 y Date Application Expires: Staff 13ials: Page 2 of 2 RECEIPT NO: R09 -00287 Initials: BLH User ID: ADMIN Payee: EMERALD CITY PLUMBING SET ID: S000001173 SET NAME: Tmp set/Initialized Activities SET TRANSACTIONS: Set Member Amount PG0:970 Y9 PG09 -020 PG09 -021 TOTAL: ACCOUNT ITEM LIST: Description PLUMBING - NONRES City of Tukwila, Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206-431-3665 Web site: http : /hvww. ci. tukwila. wa. us 300:00 196.00 170.00 300.00 SET RECEIPT Paymi Total TRANSACTION LIST: Type Method Description Amount Payment Check 6086 666.00 TOTAL: 666.00 0905101-1 0 111 02/20/2n09 001 101 DCD Permit_ Plus - General Fund $666.00 Account Code Current Pmts 000.322.103.00.0 666.00 TOTAL: 666.00 City of Tukwila 6200 Southcenter Blvd, Tukwila, WA 1 Finance Department 0905101 -1 02/20/2009 BR1 T101 Fri Feb20,2009 11:28AM Trans #1 -11 11 $666.00 DCDGEN - DCD Permits Plus - General Fund 1 ITEM(S): TOTAL: $666.00 Check (006086) PAID $666.00 www.ci,tukwila.wa.us 206 - 433 -1835 COMMENTS: Prf/A :I (.jam, f C 4 Wk._ V 1 04 e nD — Date Called: j. J D ate Wanted: { V- Phone No: ..,66 7 /(g - o //G un■r.S 7 D3 77a1 i ut i ( 5 303, s-6 Li A-- () 3j 3 °L— (-v 7 24 s _, . �' /!�( / () Z t 2_ S i4IQE 1Afp e.€ ,6k , Projec : /-,/,A�hi el Type of Inspection , J✓� / ,- 4 Address; 83 y/ s is2 6.4 Date Called: Special Instructions: • Z J ' / ) D ate Wanted: Requester: Phone No: ..,66 7 /(g - o //G PERMIT NO. CITY OF TUKWILA BUILDING DIVISION r 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 INSPECTION' NO. INSPECTION RECORD Retain a copy with permit Approved per applicable codes. Corrections required prior to approval. Inspg ctor: Date :_ / 0 � 9 ❑ $60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: Date: X 07 r7 Bond Bond Company Name Bond Account Number Effective Date Expiration Date Cancel Date Impaired Date Bond Amount Received Date 1 STATE FARM FIRE Et CAS CO 98CT66135 03/05/2004 Until Cancelled $12,000.00 03/08/2004 Name Role Effective Date Expiration Date MACIASZYL, RORY T PRESIDENT 03/11/2004 Amount MACIASZYK, MARCI L SECRETARY 03/11/2004 98BCP4458 Insurance Company Name Policy Number Effective Date Expiration Date Cancel Date Impaired Date Amount Received Date 6 STATE 98BCP4458 12/07/200812/07 /2009 $1,000,000.0010 /27/2008 FARM Untitled Page General /Specialty Contractor A business registered as a construction contractor with LEtJ to perform construction work within the scope of its specialty. A General or Specialty construction Contractor must maintain a surety bond or assignment of account and carry general liability insurance. Business and Licensing Information Name Phone Address Suite /Apt. City State Zip County Business Type Parent Company EMERALD CITY PLUMBING INC 4257763344 211 185TH PL SW BOTHELL WA 980126219 SNOHOMISH Corporation UBI No. Status License No. License Type Effective Date Expiration Date Suspend Date Previous License Next License Associated License Specialty 1 Specialty 2 602305181 ACTIVE EMERACP964DJ CONSTRUCTION CONTRACTOR 3/8/2004 3/8/2010 EMERACP015B7 GENERAL UNUSED Business Owner Information Bond Information Insurance Information • • Page 1 of 2 https: // fortress .wa.gov /lni/bbip /Detail.aspx ?License= EMERACP964DJ 02/19/2009