Loading...
HomeMy WebLinkAboutPermit PG09-037 - KHAN DEVELOPMENTKHAN DEVELOPMENT 13815 MACAD M Parcel No.: 3229200005 Address: Suite No: Tenant: Name: Address: Owner: Name: Address: Cityif Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us 13815 MACADAM RD S TUKW KHAN DEVELOPEMENT 13815 MACADAM RD S , TUKWILA WA SANDHU SUKHCHAIN S 12813 53RD DR SE , EVERETT WA Contact Person: Name: DAN PARO Address: 5917 195 ST NE #3 , ARLINGTON WA Contractor: Name: SOUND VIEW PLUMBING INC Address: 15000 40 AVE NE STE 1 , MARYSVILLE WA Contractor License No: SOUNDVP033NF DESCRIPTION OF WORK: REPLACE AND REPAIR BROKEN SEWER AND /OR WATER PIPE Value of Plumbing /Gas Piping: Fees Collected: $105.00 Plumbing Bathtub or combination bath/shower Bidet Clothes washer, domestic Dental unit, cuspidor Dishwasher, domestic, with independent drain Drinking fountain or water cooler (per head) Food -waste grinder, commercial Floor drain Shower, single head trap Lavatory Wash fountain Receptor, indirect waste Sinks Urinals Water Closet doc: UPC -10/06 FIXTURE TYPE AND QUANTITY * *continued on next page ** PLUMBING /GAS PIPING PERMIT Permit Number: Issue Date: Permit Expires On: Phone: Phone: 425 - 760 -6444 Phone: 360 - 658 -6020 Expiration Date: 06/13/2009 PG09 -037 04/10/2009 10/07/2009 $0.00 Uniform Plumbing Code Edition: 2006 International Fuel Gas Code Edition: 2006 Plumbing (cont.) 0 Building sewer and each trailer park sewer 0 0 Rain water system - per drain (inside bldg) 0 0 Water heater and /or vent 0 0 Industrial waste treatment interceptor, including 0 its trap and vent, except for kitchen type 0 grease interceptors 0 0 Repair or alteration of water piping and /or water 0 treatment equipment 0 0 Repair or alteration of drainage or vent piping 0 0 Medical gas piping system serving (1 -5) 0 inlets /outlets for a specific gas 0 0 Medical gas piping (6 +) inlets /outlets 1 0 Gas Piping 0 Gas piping outlets (0 -5) 0 0 Gas piping outlets (6 +) 0 PG09 -037 Printed: 04 -10 -2009 Permit Center Authorized Signature: Signature: Print Name: )4 /" /dX doc: UPC -10/06 City oPTukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us Permit Number: PG09 -037 Issue Date: 04/10/2009 Permit Expires On: 10/07/2009 ALL Date: Lk -tO'0 f I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of t s permit do s not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or performs a of work. I am authorized to sign and obtain this plumbing /gas piping permit. Date:7 1 / d —01 This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. PG09 -037 Printed: 04 -10 -2009 Parcel No.: 3229200005 Address: Suite No: Tenant: 1: ** *PLUMBING AND GAS PIPING * ** 5: No portion of any plumbing system or gas piping shall be concealed until inspected and approved. doc: Cond -10/06 • • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us 13815 MACADAM RD S TUKW KHAN DEVELOPEMENT PERMIT CONDITIONS * *continued on next page ** Permit Number: Status: Applied Date: Issue Date: PG09 -037 ISSUED 04/10/2009 04/10/2009 2: No changes shall be made to applicable plans and specifications unless prior approval is obtained from the Tukwila Building Division. 3: All permits, inspection records and applicable plans shall be maintained at the job and available to the plumbing inspector. 4: All plumbing and gas piping systems shall be installed in compliance with the Uniform Plumbing Code and the Fuel Gas Code. 6: All plumbing and gas piping systems shall be tested and approved as required by the Plumbing Code and Fuel Gas Code. Tests shall be conducted in the presence of the Plumbing Inspector. It shall be the duty of the holder of the permit to make sure that the work will stand the test prescribed before giving notification that the work is ready for inspection. 7: No water, soil, or waste pipe shall be installed or permitted outside of a building or in an exterior wall unless, adequate provision is made to protect such pipe from freezing. All hot and cold water pipes installed outside the conditioned space shall be insulated to minimum R -3. 8: Plastic and copper piping running through framing members to within one (1) inch of the exposed framing shall be protected by steel nail plates not less than 18 guage. 9: Piping through concrete or masonry walls shall not be subject to any load from building construction. No plumbing piping shall be directly embedded in concrete or masonry. 10: All pipes penetrating floor /ceiling assemblies and fire - resistance rated walls or partitions shall be protected in accordance with the requirements of the building code. 11: Piping in the ground shall be laid on a firm bed for its entire length. Trenches shall be backfilled in thin layers to twelve inches above the top of the piping with clean earth, which shall not contain stones, boulders, cinderfill, frozen earth, or construction debris. 12: The issuance of a permit or approval of plans and specifications shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the Plumbing Code or Fuel Gas Code or any other ordinance of the jurisdiction. PG09 -037 Printed: 04 -10 -2009 • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us I hereby certify that I have read these conditions and will comply with them as outlined. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provision of any other work or local laws regulating construction or the „performance of work. Signature: Print Name: doc: Cond -10/06 /9 etJ 4120 Date: PG09 -037 Printed: 04 -10 -2009 Contact Person: E -Mail Address: • CITY OF TUKWILA Community Development Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www.ci.tukwila.wa.us Tenant Name: U N K ND ui Name: P■ iNLO PLUMBING / GAS PIPING PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. * *Please Print ** SITE LOCATION p King Co Assessor's Tax No.: 3)21 ' 0 0 0 c Site Address: 1 3 O 1 . 5 V Ne, Pt b (A\ S J CX 1 Suite Number: Floor: Property Owners Name: Mailing Address: CONTACT PERSON - Who do we contact when your permit is ready to be issued Mailing Address:.`="i (7 19s SY Jo E. 3 State Zip E -Mail Address: Fax Number: V - Y7 73 O 2- Company Name: 5 co P•3b FiN IAAiSt 3 b ( &DC_ Mailing Address: T 5 3 IZUoG7dN wet 9 ZZ-3 State Zip Contact Person: 0 .oLT $.1NN iJl-- E -Mail Address: b U I £ui 1 4 - 7" O E,&2.1 bA) • to l/✓`• Contractor Registration Number: 553 t■-)b \RC' 33 N F ARCHITECT OF RECORD y All plans must be wet 'stamped by Architect of Record. Company Name: Mailing Address: H:Upplications\Forms- Applications On Line12009 Applications \1 -2009 - Plumbing -Gas Piping Permit Application. doe Revised: 1.2009 bh Plumbing /Gas Permit No. ?o7-6 Project No. (For office use only) City City New Tenant: ❑ Yes ❑ ..No State State Zip Day Telephone: y2 S — 76O - tl (NV �rw ATON wA 98 City Day Telephone: 3 60 - ( ( - 7 4 ( O0 Fax Number: 3(„o - (17y q - ! 3 6 Z Expiration Date: 6- (3 "a 9 Zip City Day Telephone: Fax Number: . ENGINEER OF RECORD - All plans must be wet stamped by Engineer of Record Company Name: Mailing Address: City State Zip Contact Person: Day Telephone: E -Mail Address: Fax Number: Page 1 of 2 Fixture Type: Qty Fixture Type: Qty Fixture Type: Qty Fixture Type: Qty Bathtub or combination bath/shower Bidet Clothes washer, domestic Dental unit, cuspidor Dishwasher, domestic, with independent drain Drinking fountain or water cooler (per head) Lavatory Food -waste grinder, commercial Wash fountain Floor Drain Receptor, indirect waste Shower, single head trap Sinks Urinals Water Closet Building sewer and each trailer park sewer Each grease trap (connected to not more than 4 fixtures - <750 gallon capacity) Medical gas piping system serving 1 -5 inlets /outlets for a specific gas Rain water system — per drain (inside building) Water heater and/or vent Industrial waste treatment interceptor, including trap and vent, except for kitchen type grease interceptors Repair or alteration of drainage or vent piping Grease interceptor for commercial kitchen ( >750 gallon capacity) Repair or alteration of water piping and/or water treatment equipment Each additional medical gas inlets /outlets greater than 5 Backflow protective device other than atmospheric -type vacuum breakers 2 inch (51 mm) diameter or smaller Backflow protective device. other than atmospheric -type vacuum breakers over 2 inch (51 mm) diameter Each lawn sprinkler system on any one meter including backflow protection devices Atmospheric -type vacuum breakers not included in lawn sprinkler backflow protections (1.5) Atmospheric -type vacuum breakers not included in lawn sprinkler backflow protections over 5 Gas piping outlets PERMIT APPLICATION NOTES - • Valuation of Project (contractor's bid price): $ 7 5-o Q G Scope of Work (please provide detailed information): t ACS. A&j 12_4-1p A 1 R TZLA / ^J L./NE S 0 N`r & -1 r. 6 ,')k - Pt. Ae.c__. a KV_IP A/C_ >.v Building Use (per Int'l Building Code): Occupancy (per Int'l Building Code): Utility Purveyor: Water: Indicate type of plumbing fixtures and /or gas piping outlets being installed and the quantity below: Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may grant one extension of time for an additional period not to exceed 180 days. The extension shall be requested in writing and justifiable cause demonstrated. Section 103.4.3 International Plumbing Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING 0 Signature: 1/ � t/te&, 0-"Ar_ Date: q— id ^ 4 Print Name: i JIQ4 1• A-2 Day Telephone: Da Tele hone: `715 - 76 0 - 6' "NV Mailing Address: 51 1 7 — 1 75 7/4 sr P 3 Aetbv W A 982 73 Date Application Accepted: R OR A HORIZED AGENT: Date Application Expires: H:Wpplications\Forms- Applications On Line12009 Applications1l -2009 - Plumbing -Gas Piping Permit Application doc Revised: 1-2009 bh Sewer: city State Zip Staff Initials: Page 2 of 2 Parcel No.: 3229200005 Address: 13815 MACADAM RD S TUKW Suite No: Applicant: KHAN DEVELOPEMENT Payee: SOUIND VIEW PLUMBING ACCOUNT ITEM LIST: Description PLUMBING - RES • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us TRANSACTION LIST: Type Method Descriptio Amount Payment Check 13959 45.00 Authorization No. RECEIPT Receipt No.: R09 -00555 Payment Amount: $45.00 Initials: WER Payment Date: 04/10/2009 11:49 AM User ID: 1655 Balance: $0.00 Account Code Current Pmts 000.322.103.00.0 45.00 Total: $45.00 Permit Number: PG09 -037 Status: PENDING Applied Date: 04/10/2009 Issue Date: PAYMENT RECEIVED doc: Receiot -06 Printed: 04 -10 -2009 Project: \ // A' #A9.erkt Type of Inspection: 1 ,• 4 Address: / 3 G3i % may ' - "4' , Je Date Called: c Special Instructions: /v 3u Date,Wanted: , ? 7. 05 p.m. Requester: Phone No: 1 7/25- y7 -c30 0 INSPECTION RECORD Retain a copy with permit INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 P60i -d3 7 PERMIT NO. (206)431 -3670 I XI Approved per applicable codes. 0 Corrections required prior to approval. ' COMMENTS: 7 (7 ,;J/' % Assmal Receipt No.: Date a2— .00 REINSPECTION F. E REQU .° ED. Prior to inspection, fee must be aid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Date: era COMMENTS: kto - S,J, Si e. I• ,.4 '..A 'z) 1 , i '/l't O, -) I .1 •. J - 2 r' " VIAi 7 -1. ) r`■O 1 4 ,E 7-J r A nr a 4 r :7 d d AId7 I(f\ .D U :r p.'14) /(,o(A - re I AJ _ 4"t4 .1_,I r) ,„... `T ~J �(S ( I D ! , • ' -s e err l . / 0 ` iT` i5 -Surf A •. f. dt-P.4 b• /,JA - rf / � 1 1 C & ,(-P 4_;,11( rut Special Instructions: D 3319(-1 AC - � � — ei : A' '\ A '� i ; -3is -301 ' Air./ ) - , , , i •-, : r ‘):'..r : A . -/ �� a.m. � ~ Requester: Project: T o Inspectio Address: . 1 3.x(S 4, n .o Called: Special Instructions: D 3319(-1 AC - � � — ei : A' '\ A '� i ; -3is -301 Date Wanted: -/ �� a.m. � ~ Requester: Phone No: 42 - '7 60 -64441 INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION le- 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 ❑ Approved per applicable codes. 1) (961 - O 3 7 Corrections required prior to approval. . Inspect I: f 2 ( d ? El $60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: Date: _ Project: /<7 AJ .Of (/ Type of Inspection: / "/4 / -- �ht et, 6 Address: /3 5/ S 41A,444mi9'i ,Q Date Called: Special Instructions: Date Wanted: '- / 6 - ec +�ttt,`. p.m. Requester: Phone No: y25 76 a - Yl'U INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 El Approved per applicable codes. Corrections required prior to approval. COMMENTS: ,mt ec ,f a''FSS Re•eipt No.: 'Date: Date: $ .00 REINSPEC ION FEE REQ ' ED. Pri to inspection, fee st be id at 6300 Southcenter Blvd., Sui e 100. all to schedule rei pection. License Name Type Specialty 1 Specialty 2 Effective Date Expiration Date Status DAYNNPW087M0 DAY N NIGHT PLBG OF WENAT INC CONSTRUCTION CONTRACTOR GENERAL UNUSED 7/20/1992 7/1/1999 ARCHIVED Name Role Effective Date Expiration Date TREMMEL, CURTIS J Cancel Date 01/01/1980 Bond Amount TREMMEL, TAMMY J 2 01/01/1980 3 384643 TREMMEL, MARY L Until Cancelled 01/01/1980 JOHNSON, PHIL 05/16/2002 01/01/1980 OHIO Bond Bond Company Name Bond Account Number Effective Date Expiration Date Cancel Date Impaired Date Bond Amount Received Date 2 OHIO CAS INS CO 3 384643 06/01 /2002 Until Cancelled $12,000.00 05/16/2002 OHIO Untitled Page General /Specialty Contractor A business registered as a construction contractor with LEtI to perform construction work within the scope of its specialty. A General or Specialty construction Contractor must maintain a surety bond or assignment of account and carry general liability insurance. Business and Licensing Information Name Phone Address Suite /Apt. City State Zip County Business Type Parent Company SOUND VIEW PLUMBING INC 3606586020 15000 40TH AVE NE STE 1 MARYSVILLE WA 98271 SNOHOMISH Corporation UBI No. Status License No. License Type Effective Date Expiration Date Suspend Date Specialty 1 Specialty 2 601784464 ACTIVE SOUNDVP033NF CONSTRUCTION CONTRACTOR 8/6/1997 6/13/2009 GENERAL UNUSED Other Associated Licenses Business Owner Information Bond Information • • Page 1 of 2 https: // fortress .wa.gov /lni/bbip/Detail.aspx 04/10/2009