Loading...
HomeMy WebLinkAboutPermit PG09-052 - RAINIER INDUSTRIESRAINIER IN UST IES PGO9-052 18375 OLYMPIC AV S Parcel No.: 7888900130 Address: Suite No: Tenant: Name: RAINIER INDUSTRIES Address: 18375 OLYMPIC AV S , TUKWILA WA Owner: Name: RAINIER INDUSTRIES LTD Address: 18375 OLYMPIC AV S , TUKWILA WA Contact Person: Name: CHRISTINE JOHNSON Address: PO BOX 249 , AUBURN WA Contractor: Name: AUBURN MECHANICAL INC Address: PO BOX 249 , AUBURN, WA Contractor License No: AUBURMI163BA DESCRIPTION OF WORK: INSTALL 3/4" RPBA FOR GRAY WATER LINE RUNNING FROM BATCH OVEN. RPPA IS A WATTS 009. GAS PIPING FOR BATCH OVEN. INCLUDES ALSO A SUMP PUMP INSTALLATION. Value of Plumbing /Gas Piping: Fees Collected: doc: UPC -7/07 18375 OLYMPIC AV S TUKW Cityf Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us $9,000.00 $205.00 Plumbing Bathtub or combination bath/shower Bidet Clothes washer, domestic Dental unit, cuspidor Dishwasher, domestic, with independent drain Drinking fountain or water cooler (per head) Food -waste grinder, commercial Floor drain Shower, single head trap Lavatory Wash fountain Receptor, indirect waste Sinks Urinals Water Closet PLUMBING /GAS PIPING PERMIT FIXTURE TYPE AND QUANTITY * * continued on next page ** Permit Number: Issue Date: Permit Expires On: Phone: Phone: 253 - 838 -9780 Phone: (253)838 -9780 Expiration Date: 09/12/2010 PG09 -052 07/02/2009 12/29/2009 Uniform Plumbing Code Edition: 2006 International Fuel Gas Code Edition: 2006 Plumbing (cont.) 0 Building sewer and each trailer park sewer 0 0 Rain water system - per drain (inside bldg) 0 0 Water heater and /or vent 0 0 Industrial waste treatment interceptor, including 0 its trap and vent, except for kitchen type 0 grease interceptors 0 0 Repair or alteration of water piping and/or water 0 treatment equipment 0 0 Repair or alteration of drainage or vent piping 0 0 Medical gas piping system serving (1 -5) 0 inlets /outlets for a specific gas 1 0 Medical gas piping (6 +) inlets /outlets 0 0 Gas Piping 0 Gas piping outlets (0 -5) 1 0 Gas piping outlets (6 +) 0 PG09 -052 Printed: 07 -02 -2009 Permit Center Authorized Signature: I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permi construction or the pe Signature: Print Name: doc: UPC -7/07 Joe_ City ofTukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206- 431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us • Permit Number: PG09 - 052 Issue Date: 07/02/2009 Permit Expires On: 12/29/2009 Date: -0 9 not presume to give authority to violate or cancel the provisions of any other state or local laws regulating of work. I am authorized to sign and obtain this plumbing /gas piping permit. ^� Date: / " - 3 5 This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. PG09 -052 Printed: 07 -02 -2009 Parcel No.: 7888900130 Address: Suite No: Tenant: RAINIER INDUSTRIES 1: ** *PLUMBING AND GAS PIPING * ** • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us 18375 OLYMPIC AV S TUKW PERMIT CONDITIONS Permit Number: Status: Applied Date: Issue Date: PG09 -052 ISSUED 06/01/2009 07/02/2009 2: No changes shall be made to applicable plans and specifications unless prior approval is obtained from the Tukwila Building Division. 3: All permits, inspection records and applicable plans shall be maintained at the job and available to the plumbing inspector. 4: All plumbing and gas piping systems shall be installed in compliance with the Uniform Plumbing Code and the Fuel Gas Code. 5: No portion of any plumbing system or gas piping shall be concealed until inspected and approved. 6: All plumbing and gas piping systems shall be tested and approved as required by the Plumbing Code and Fuel Gas Code. Tests shall be conducted in the presence of the Plumbing Inspector. It shall be the duty of the holder of the permit to make sure that the work will stand the test prescribed before giving notification that the work is ready for inspection. 7: No water, soil, or waste pipe shall be installed or permitted outside of a building or in an exterior wall unless, adequate provision is made to protect such pipe from freezing. All hot and cold water pipes installed outside the conditioned space shall be insulated to minimum R -3. 8: Plastic and copper piping running through framing members to within one (1) inch of the exposed framing shall be protected by steel nail plates not less than 18 guage. 9: Piping through concrete or masonry walls shall not be subject to any load from building construction. No plumbing piping shall be directly embedded m concrete or masonry. 10: All pipes penetrating floor /ceiling assemblies and fire - resistance rated walls or partitions shall be protected in accordance with the requirements of the building code. 11: Piping in the ground shall be laid on a firm bed for its entire length. Trenches shall be backfiIled in thin layers to twelve inches above the top of the piping with clean earth, which shall not contain stones, boulders, cinderfill, frozen earth, or construction debris. 12: The issuance of a permit or approval of plans and specifications shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the Plumbing Code or Fuel Gas Code or any other ordinance of the jurisdiction. 13: ** *PUBLIC WORKS DEPARTMENT CONDITIONS * ** 14: PROPOSED RPPA AND SUMP PUMP SHALL BE INSTALLED PER MANUFACTURERS SPECIFICATIONS. 15: THE RPPA SHALL BE TESTED ON ANNUAL BASIS BY A CERTIFIED BACKFLOW TESTER AT OWNERS EXPENCE. doc: Cond -10/06 PG09 -052 Printed: 07 -02 -2009 doc: Cond -10/06 0 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us * *continued on next page ** PG09 -052 • Printed: 07 -02 -2009 • 0 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us I hereby certify that I have read these conditions and will comply with them as outlined. All provisions of law and this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provision of any other work construction or the performan = _.._work. Signature: Print Name: c) - / h Giq doc: Cond -10/06 PG09 -052 Date: 7r _z - / ordinances governing or local laws regulating Printed: 07 -02 -2009 CITY OF TUKWIN Community Development Department Public Works Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www.ci.tulcwila.wa.us abIo .451 .3(t 1O SITE LOCATION Site Address: 3M- 019 rip 1 C� *v S Tenant Name: .,a I r I ✓ Ind S Property Owners Name: AC .0 S S IZ h am✓ -1'1'1 �X S Mailing Address: 1 'e3 `4 35 O l y YYl p *i iiV€- S CONTACT PERSON - who do we contact when your permit is ready to be issued Name: E -Mail Address: Christine Johnson Mailing Address: P.O. Box 249 E -Mail Address: christine @auburnmechanical.com Company Name: Auburn Mechanical, Inc. Mailing Address: P.O. Box 249 Contact Person: Christine Johnson Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. * *Please Print ** E -Mail Address:_ christine @auburnmechanical.com Contractor Registration Number: Al IRI IRMI183RA Q:\Applications\Forms- Applications On linen- 2006 - Permit Application.doc Revised: 9 -2006 bh Building Permit No. Mechanical Permit No. Plumbing/Gas Permit No. a, 0Sz Public Works Permit No. Project No. (For ofce use only) King Co Assessor's Tax No.: 1 &9 t<] 1 0 0 1 e' - I Suite Number: Floor: New Tenant: ❑ Yes a..No Lt.._ C., T t.kbut la WA `h ?1 t ?X City State Zip Day Telephone:_ 253 -838 -9780 Auburn WA Auburn Fax Number: 253- 833 -1384 GENERAL CONTRACTOR INFORMATION — (Contractor Information for Mechanical (pg 4) for Plumbing and Gas Piping (pg 5)) WA ;` state Day Telephone: 253 - 838 -9780 Fax Number: 253 - 833 -1384 Expiration Date: 9/12/08 ARCHITECT OF RECORD - All plans must be wet stamped by Architect of Record Company Name: Mailing Address: City Contact Person: Day Telephone: E -Mail Address: Fax Number: State 98071 98071 Zip ENGINEER OF RECORD - All plans must be wet stamped by Engineer of Record Company Name: g ap 1 c En 9 I n F V 1 r Mailing Address: Zip State City Contact Person: Day Telephone: Fax Number: Page 1 of 6 Fixture Type: Qty Fixture Type: Qty Fixture Type: Qty Fixture Type: Qty Bathtub or combination bath/shower Drinking fountain or water cooler (per head) Wash fountain Gas piping outlets I Bidet Food -waste grinder, commercial Receptor, indirect waste y ■ 0 Uv C.t 4tv ( l 1 c f Clothes washer, domestic Floor drain Sinks Dental unit, cuspidor Shower, single head trap Urinals Dishwasher, domestic, with independent drain Lavatory Water Closet Building sewer or trailer park sewer Rain water system — per drain (inside building) Water heater and/or vent Additional medical gas inlets /outlets — six or more Industrial waste pretreatment interceptor, including its trap and vent, except for kitchen type grease interceptors Repair or alteration of water piping and/or water treating equipment Repair or alteration of drainage or vent piping Medical gas piping system serving one to five inlets/outlets for specific gas Q:\Applications\Fonns- Applications On Line\3 -2006 - Permit Application.doc Revised: 9 -2006 bh • 0 PLUMBING AND GAS PIPING PERMIT INFORMATION - 206 - 431 -3670 PLUMBING AND GAS PIPING CONTRACTOR INFORMATION Company Name: Aubum Mechanical, Inc. Mailing Address: P.O. Box 249 Auburn WA 98071 wit Stale Zip Contact Person:_ Christine Johnson Day Telephone: 253 -838 -9780 E -Mail Address: christine a(�,auburnmechanical.com Fax Number: 253 - 833 -1384 Contractor Registration Number: AUBURMI163BA Expiration Date: 9/12/08 3 000 Valuation of Plumbing work (contractor's bid price): $ Valuation of Gas Piping work (contractor's bid price): $ Scope of Work (please provide detailed information): Ifl - ►►ln 3/4 " RPP)tti -Foy q(4 w *rr Imp_ twining from b'd +c'i bu ctIx . P i s 2 SU S o o 9 ol etc � '�"r✓� o ve n Building Use (per Int'I Building Code): Occupancy (per Int'l Building Code): Utility Purveyor: Water: Sewer: Indicate type of plumbing fixtures and/or gas piping outlets being installed and the quantity below: Page 5 of 6 PERMIT APPLICATION NOTES — Applicable to all permits in this application Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING Signature: Building and Mechanical Permit The Building Official may grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). Plumbing Permit The Building Official may grant one extension of time for an additional period not exceeding 180 days. The extension shall be requested in writing and justifiable cause demonstrated. Section 103.4.3 Uniform Plumbing Code (current edition). 1 R O AUTH Print Name: Christine Johnson Mailing Address: P.O. Box 249 Q:Wpplications\Fomss- Applications On Line U-2006 - Permit Application.doc Revised: 9 -2006 hh Day Telephone: 253 - 838 -9780 Auburn WA Date: State 98071 I Date Application Accepted: Cp-1 -09 Date Application Expires: Staff Initials: iiti 1 Page 6 of 6 Parcel No.: 7888900121 Address: 18435 OLYMPIC AV S TUKW Suite No: Applicant: RAINIER INDUSTRIES Receipt No.: R09 -00816 Payee: AUBURN MECHANICAL t Q City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us Initials: WER Payment Date: 06/01/2009 03:15 PM User ID: 1655 Balance: $0.00 TRANSACTION LIST: Type Method Descriptio Amount Payment Check 0010173 205.00 Authorization No. ACCOUNT ITEM LIST: Description GAS - NONRES PLAN CHECK - NONRES PLUMBING - NONRES RECEIPT Account Code Current Pmts 000.322.103.00.0 000/345.830 000.322.103.00.0 Permit Number: PG09 -052 Status: PENDING Applied Date: 06/01/2009 Issue Date: Payment Amount: $205.00 92.00 41.00 72.00 Total: $205.00 E, ECERVE doc: Receiot -06 Printed: 06 -01 -2009 Project: nl el �r►G�i- fS s Type of I spear n: e� t''I►ct Address: 183 DIt-rl1r3Ic 45 Date Called: 07/06/09 Special Instructions: C )5; 1/11'k -pi, U f i 0 1 1Spc t f yi\ Date Wanted: 0 WO 7 / 0 9 a. i. . Requester: . Phone No: (34 096,-9 6 INSPECTION NO. INSPECTION RECORD Retain a copy with permit p605.--as PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 ri Approved per applicable codes. Corrections required prior to approval. COMMENTS: Inspector: ep 5 Date: -7 1 - to l n $60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Recei pt_ No.: 'Date: si,Mti_ . ..�.�h•_J..�tae..Sn�eb.,�r _ -_ _ ... ...: Yd:i ..:�.t....k .►.. .�- COMMENTS: C / Type of Inspection: ^( L // ` / / Address: 1 3 ? S -j M nr c. 14- Date Called:* /' [ �� r .' n ..�� „""" - S. l vWnn 1 1 Special Instructions: / / /� A i \ TIS 1_,..-z.“-- ft ( e_jf _ Requester: Phone No 3y6,17 i (I —C%- 4,4 (! L. v�o fGL- N k kr e f A J e,ef \k f A. A ho `,'✓ir D - Pro C((� C / Type of Inspection: ^( L // ` / / Address: 1 3 ? S -j M nr c. 14- Date Called:* /' [ �� r .' n ..�� „""" - S. l vWnn 1 1 Special Instructions: / / /� Date Wanted: a.m r 7 -o ff Requester: Phone No 3y6,17 pt? $ °/ PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 0TL INSPECTION NO. INSPECTION RECORD Retain a copy with permit Approved per applicable codes. Corrections required prior to approval. Inspector: Date: 67. 0 $60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: IDate: 6 Proj$ct: • n t e- - 41-4 'type of Inspectk . n ( 4,,,01,..t & Address: ( 3 3 15 o 1/2 i ?: .p n Date Called: i g. J K I CAx P,- Special Instructions: o3'1 1 0 it RPa 6r e Date Wanted: _ aa.. `_' Requ Phone No: f,400 3 q ( - 1 9240 INSPECT r ON NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 INSPECTION RECORD Retain a copy with permit pproved per applicable codes. Corrections required prior to approval. COMMENTS: PrSrls I A- 1,4Je, CivIA IA...1 A f Cf I t Insp¢ctor: Date: 1 v S El $60.00 REINSPECTION FEE REQUIRED. to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: 'Date: INITIAL TEST PASSED DCVAIRPBA DCVA /RPBA RPBA PVBA/SVBA CHECK VALVE NO.1 CHECK VALVE NO.2 OPENED AT Y- 3 PSI AIR INLET OPENED AT PSI[ #1 CHECK 9- C PSII AKED • 9- G PSI( LEAKED • C � PSI AIR GAP OK? j DID NOT OPEN • FAILED • NEW PARTS AND REPAIRS CLEAN REPLACE PART CLEAN REPLACE PART CLEAN REPLACE PART CHECK VALVE HELD AT PSIC • • • • • • LEAKED • • • • • • • CLEANED ❑ • • • • • • REPAIRED • TEST AFTER REPAIRS OPENED AT PSIC AIR INLET PSID LEAKED • PSI LEAKED • PSI #1 CHECK PSIC CHK VALVE PSID PASSED • FAILED • FROM: AUBURN MECHANICAL, INC. ADDRESS: P.O. BOX 249 AUBURN, WA 98001 (253) 838 -9780 / (253) 929 -1426 ACCOUNT # BACKFLOW PREVENTION ASSEMBLY TEST REPORT JOB # pex tr ' P &act 65 NAME OF PREMISE ea o / ' TA9da $ `fir i e S Commercial Il Residential ❑ SERVICE ADDRESS /8375 ci fri P;c 19Ve _ S. CITY _ t14 ii w1 Ott, ZIP ygllie3 CONTACT PERSON PHONE ( ) FAX ( ) LOCATION OF ASSEMBLY yyj < a tecl to Bac& Side_ 6e w i 13c1) DOWNSTREAM PROCESS Pre Ssaar w 6 i e.( DCVA ❑ RPBA £iY PVBA ❑ OTHER Itd NEW INSTALL 4XISTING ❑ REPLACEMENT ❑ OLD SER. # PROPER INSTALLATION? YES L9'NO ❑ MAKE OF ASSEMBLY too I S I E S MODELo 9p13 4 7 1 - - - SERIAL NO. 13 (9 /3(o) SIZE '+/ 7 AIR GAP INSPECTION: Required minimum air gap separation provided? Yes No ❑ Detector Meter Reading REMARKS: LINE PRESSURE YO PS CONFINED SPACE ?t'? TESTERS SIGNATURE: TESTERS NAME PRINTED: ( f (5 tr pJ er REPAIRED BY: r I I9 !? CERT. NO. 8 3/02— DATE 7- ro - 'J TESTERS PHONE # (23 ) f i DATE FINAL TEST BY: CERT. NO. DATE CALIBRATION DATE LOI /eibbAUGE #C945 MODEL = 3 SERVICE RESTORED? YES L`J' NO ❑ 1 certify that this report is accurate, and 1 have used WAC 246- 290 -490 approved test methods and test equipment. . , t. mo•i- • • .1:II ' 4 3. S '3AV OldNIA10 REVIE CODE COMPLIANCE 4PPROVED JUN 2 6 2009 city of Tukwila wtt- BUIWIVIVISION 15431- Oly—t1;c A El 111.11.111• ....(1 _Lit . • A - .1 –I -. :: 1 —Fel ,, . i i . ,.........4.4..., —__-- - -- .....,24......)...,+e , ... Elm •— LI' . , • u r- - • 19 :1 _ jirlIr LI 1 - '1; .7. e • •• ' 3 1 6 , t : dv "* .4.) ' ••••• .4., . , . -.L.2 •S ... .,. , ...1 — 9 — • lik .4. 214 elf ill ,:3 . 1 .T . " ...r 1#5;fleld Wee •— 1 • • Oute,ri• AIEWLIO REVISIONS No changes shall be made to the scope_ — — o - f - vvork - without - prier-approval of Tukwila Building Division. Tr: Revisions wiH require a new plan submittal ,••• r t:J f .? aciditional plan review fees. ••••• 3AY OldNI•110 Z1 3 0 3 7 3' 3 3 3 3 ------------- 2_004 Rawl 6 3 -, sot RECEN CM OF TU • NI{ 2 3 PERMI C - 1J tvulete„ LA 09 TER CORRECTION LTR# - 1 F ccvl iTov i */ (1 t �� • 34 x 9$ FAN OUTLET 0 ' CLEAR CF'E�INC . • a, ,7 /FLOC-7' SACK CAP EXHAJST STACK 10 "9I (M NIM„M),3 ABOVE RCOF\ JNE ROOF EL A,NGF & RAN SKIRT SQUARE -TO- ROUND � FI "ING 0 ' C -EAR 0 END VIF -',,N / DOOR SWING J / o .1 / 6 -2' / RFC RC AIR r DIS ON / ll •^ / CLEAR' HE CH- REC'D CLEARANCE REVISIONS No changes shall be made to the scope of work without prior approval of Tukwila Building Division. NOTE: Revisions will require a new plan submittal i and may include additional plan review fees EC RCJ_A NC ODERA - .NC TEMPERA THERMCCOUDLE C - O_ 0 0 Lc 26 OVEN .D (52; 3x6 x3 NOZZLES J SE` W 24;'W ( AVG.) 3000 `YP. FX -AUS cAN Aop r Stock •71■111s:wa: C 26 -5' '\ PLAN VIEW 9' -6" - 1. EL S.tDF_° OONNEC ON. NA - uRAL GAS 2100 CFH. ( DRCOANE 840 CFH) MA N E_ECTR CA_ ENC'_0S ,RE./ CONTROL °ANE_ - ELD LOCA - E ELECTRICAL J CT ON \ 5'DE VIEW 9 -3' Aoo -ex NEC RC' A R Stock C.U.. NOZZLES PE „RN • AR OPENING FM GAS 'RAIN I H "G- TEMR. LIMIT `- IERMCC0JP_E OEN "ED <D_R NOZZLE AS SHOWN CCMBuST•CN A cIL -ERS • • 2' -6" T 1 OVEN I D. . - YP r COMBUSTION A R FLCW REV# REVISION DATE BY SUPPLY GAS PRESSURE REVISION INFORMATION BATCH OVEN SPECIFICATIONS: RECIRCULATING FAN 21 "FC,, 114,500 SCFM © 1 .7" SP MOTOR 10 HP' 11750 RPM, ODP EXHAUST FAN , GP -PLR, 1 22, 1400 ACFM 1 "SP ©70'F MOTOR 1 HP' 1'750 RPM, ODP BURNER CAPACITY 3.5 FE, MAXON NP -L 2,100',000 BTU /Hr GAS TRAIN DOWN- REGULATOR (IF REVD) FACTORY MUTUAL, 1.5" NPT 14 "W,C, (MINIMUM, ©Full Flow) 5 P511 (MAXIMUM) BY OTHERS FUEL HEATING VALUE NATURAL GAS or PROPANE. 1000 BTu /CU.FT. 2500 BTU' /CU'.FT., ELECTRICAL SERVICE' 1460V/3PH /60HZ ELECTRICAL CONTROL PANEL "UL" LISTED CONTROL OPTION'S STACK' KIT ALTI TUDE II LESS THAN 1000 FT. MAX. POWDER LOADING 145 LB/BATCH MAX. SOLVENT LOADING MINIMUM PRE - IGNITION PURGE OPERATING TEMPERATURE WALL, ROOF, B.BOX PANELS 0.63 GAL /BATCH 12 MINUTES © 1400 CFM EXHAUST 450'F 20 GA., ALUMINIZED OVER 6" INSULATION EXHAUST STACK /ROOF FLASHING CLEAR WORK OPENING FIRE PROTECTION ACCESS LADDERS, MEZZANINES, PERSONNEL GUARD RAILS ILE COPY PROVIDED BY RAPID, SPIRAL PIPE & ROOF SEAL BY OTHERS 1 0'W x, 10'H x 25'L BY OTHERS BY OTHERS NOTES: 1) THE SAFETY STANDARD FOR INDUSTRIAL OVENS, NEPA 86, REQUIRES THIS OVEN BE LOCATED SO AS TO KEEP TEMPERATURES AT COMBUSTIBLE FLOORS, CEILINGS, AND WALLS BELOW 1607. EQUIPMENT OWNER' AND END USER ARE RESPONSIBLE FOR THE RISKS ASSOCIATED WITH POTENTIAL EXPOSURE OF NEARBY COMBUSTIBLE SURFACES TO TEMPERATURES EXCEEDING 160'F, FOR AVOIDING THE OCCURRENCE OF SUCH EXPOSURE, AND FOR SATISFYING ALL LOCAL, NATIONAL AND OTHER' APPLICABLE CODES. 2) PROPER OPERATIONAL CHECKS OF FLAME DETECTOR MUST BE MADE IF USED FOR 24 HR /DAY OPERATION 3) REFER TO SAFETY LABEL. ON CONTROL PANEL FOR, FURTHER CONDITIONS OF USE OF THIS EQUIPMENT OVEN FLOOR F Permit No. ® 052, 7 -,7 City Of Tbkwila BUILDING DIVISION NONE' PI n review approval is subject to errors and omissions. 4p . royal of construction documents does not authorize tr 2 • violation of any adopted code or ordinance. Receipt a pproved Field . : < d moons is acknowledged: REVIEWED FOR CODE COMPLI APPROVED JUN 26 2009 City of Tukwila BUILDING DIVISI RECEIVE ' JUN 012009 PEHMIT CENTS REL# RELEASE DATE I BY RELEASE INFORMATION DESCRIPTION: COMMENTS: FILE LOCATION:' FOR: PROCESSING NOTE: - THIS DRA'MNG IN DESIGNI AND DETAIL`, IS' THE PROPERTY' OF RAPID ENGINEERING, AND MUST NOT BE USED EXCEPT, IN CONNECTION WITH Ol'.R WORK ALL THE RIGHTS OF DESIGN AND INVENTION ARE RESERVED BY RAPID ENGINEERING SCALE: PLOT RATO: RAPID ENGIN HERI DRAWN: CHECKED: COMSTOCK PARK,MICH 4932' DATE: SO #: DWG if WO #. REVISION G T SHEET Job me Job cation Engin er Appr JUN 2 6 2009 BUILDING DIVISION TUKWILA PUDLIC WORKS Series 009 Reduced Pressure Zone Assemblies Sizes: 1 /4" - 3" (8 - 80mm) Series 009 Reduced Pressure Zone Assemblies are designed to protect potable water supplies in accordance with national plumbing codes and water authority requirements. This series can be used in a variety of installations, including the prevention of health hazard cross connections in piping systems or for con- tainment at the service line entrance. This series features two in -line, independent check valves, cap- tured springs and replaceable check seats with an intermediate relief valve. Its compact modular design facilitates easy mainte- nance and assembly access. Sizes 1 /4" - 1" (8 - 25mm) shutoffs have tee handles. Features • Single access cover and modular check construction for ease of maintenance • Top entry - all internals immediately accessible • Captured springs for safe maintenance • Internal relief valve for reduced installation clearances • Replaceable seats for economical repair • Bronze body construction for durability 1/4" - 2" (8 - 50mm) • Fused epoxy coated cast iron body 21/2" and 3" (65 and 80mm) • Ball valve test cocks — screwdriver slotted 1/4" - 2" (8 - 50mm) • Large body passages provides low pressure drop • Compact, space saving design • No special tools required for servicing Specifications A Reduced Pressure Zone Assembly shall be installed at each potential health hazard location to prevent backflow due to backsiphonage and /or backpressure. The assembly shall con- sist of an internal pressure differential relief valve located in a zone between two positive seating check modules with cap- tured springs and silicone seat discs. Seats and seat discs shall be replaceable in both check modules and the relief valve. There shall be no threads or screws in the waterway exposed to line fluids. Service of all internal components shall be through a single access cover secured with stainless steel bolts. The assembly shall also include two resilient seated isolation valves, four resilient seated test cocks and an air gap drain fitting. The assembly shall meet the requirements of: USC Manual 8th Editiont; ASSE Std. 1013; AWWA Std. C511; CSA B64.4. Shall be a Watts Regulator Co. Series 009. tDoes not indicate approval status. Refer to Page 2 for approved sizes & models. PeasorrAllf kin RECEIVED Approval JUN-0-1-2009 Contractor's P.O. No Representative Contractor Test Cock No 3 Ball Type Test Cocks Test Cock No 2 First Check Module Assembly Relief Valve Assembly FILE COPY Now Available WattsBox;lnsulated Enclosures. For more information, send for literature ES -WB. IMPORTANT INQUIRE WITH GOVERNING AUTHORITIES FOR LOCAL INSTALLATION REQUIREMENTS !ISO, 9001 MP ; 11121 '/2" 009QT 2" 009M2QTHC ES -009 PERMIT GENTEP Test Cock No. 4 Second Check Module Assembly Water Outlet WATrS® REGULATOR USA: 815 Chestnut St., No. Andover, MA 01845 -6098; www.wattsreg.com Canada: 5435 North Service Rd., Burlington, ONT L7L 5H7; www.wattscda.com Watts product specifications in U.S. customary units and metric are approximate and are provided for reference only. For precise measurements, please contact Watts Technical Service. Watts reserves the right to change or modify product design, construction, specifications, or materials without prior notice and without incurring any obligation to make such changes and modifications on Watts products previously or subsequently sold. tI MODEL I for 909, 009 and 993 sizes DRAIN OUTLET in. min in. I DIMENSIONS A mm in. ( B mm !WEIGHT I lbs. kgs. 909AG -A ' /4 -1/4" 009, '/ 13 21/4 60 31/4 79 .625 .28 3 /4 009M2/M3 909AG -C 3 /4 -1' 009/909, 1 25 31/4 83 4'/8 124 1.50 .68 1' -11/2' 009M2 909AG -F 1V4" -2' 009M1, 2 51 4 111 6 171 3.25 1.47 1'/4 -3" 009/909, 2' 009M2, 4 "-6" 993 909AG -K 4' -' 909, 3 76 6%8 162 9 243 6.25 2.83 8 " -10' 909M1 909AG -M 8' -10' 909 4 102 7 187 11'A 394 15.50 7.03 909EL -A '/4 -'/z' 009, 3/4' 009M2/M3 - - - - - - - - 909EL-C 3 /4 -1" 009/909. - - 2% 60 2%8 60 .38 .17 * 909EL -F 11/4"-2' 009M1, - - 3%8 92 3% 92 2 .91 1'/4 -2' 009/909, 2' 009M2. 4"-6" 993 * 909EL -H 2 009/909 - - - - - - - - Vertical Available Models: 1 /4" - 2" (8 - 50mm) Suffix: QT - quarter -turn ball valves S - bronze strainer LF - without shutoff valves AQT - elbow fittings for 360° rotation 3 /4" - 2" (20 - 50mm) only PC - internal Polymer Coating LH - locking handle ball valves (open position) SH - stainless steel ball valve handles HC - 21/2" inlet/outlet fire hydrant fitting (2" valve) Prefix: C - clean and check strainer 3 / 4 " - 1 " (20 - 25mm) only U - union connections (see ES-U009) Available Models: 21/2" - 3" (65 - 80mm) Suffix: NRS - non -rising stem resilient seated gate valves OSY - UL/FM outside stem and yoke resilient seated gate valves S -FDA - FDA epoxy coated strainer QT -FDA - FDA epoxy coated quarter -turn ball valve shutoffs LF - s - without shutoff valves cast iron strainer Note: The installation of a drain line is recommended. When installing a drain line, an air gap is necessary (see ES -AG). Materials: 1 /4" - 2" (8 - 50mm) Bronze body construction, silicone rubber disc material in the first and second check plus the relief valve. Replaceable poly- mer check seats for first and second checks. Removable stain- less steel relief valve seat. Stainless steel cover bolts. Standardly furnished with NPT body connections. For optional bronze union inlet and outlet connections, specify prefix U (Yz" - 2 "(15 - 50mm)). Series 009QT furnished with quarter turn, full port, resilient seated, bronze ball valve shutoffs. Air Gaps and Elbows Materials: 21/2" and 3" (65 - 80mm) • (FDA approved) Epoxy coated cast iron unibody with bronze seats • Relief valve with stainless steel seat and trim • Bronze body ball valve test cocks Pressure / Temperature Series 009 - 2" (8 - 50mm) is suitable for supply pressure up to 175psi (12 bars). Water temperature: 33 °F - 180 °F ( -3 °C - 75 °C). Sizes 21/2" and 3" (65 and 80mm) are suitable for supply pressures up to 175psi (12 bars) and water temperature at 110 °F (43 °C) continuous, 140 °F (60 °C) intermittent. Standards USC Manual 8th Editions ASSE No. 1013 AW WA C511 -92 CSA B64.4 IAPMO File No. 1563. tDoes not indicate approval status. See below for approved models. Approvals ASSE, AWWA, CSA, IAPMO Approved by the Foundation for Cross- Connection Control and Hydraulic Research at the University of Southern California. Approval models QT, AQT, PC, NRS, OSY. UL Classified 3 /4" - 2" (20 - 50mm) (LF models only) 21/2" and 3" (65 and 80mm) with OSY gate valves. A B B MODEL I SIZE (ON) in. mm in. A mm in. B mm in. I C mm DIMENSIONS (approx.) D in. mm in. L mm in. I !I I M mm in. N mm I WEIGHT Ibs. kgs. 009QT" 1/4 8 10 250 4 117 3 86 11/4 32 51/2 - - - - - 4.50 2.0 009QT" 3 /4 10 10 250 4 117 3 86 1% 32 5'/ 140 - - - - 4,50 2.0 009QT" / 15 10 250 4 117 3 86 1 32 5% 140 - - - - 4.50 2.0 009M3QT *' 3 /4 20 10 273 5 127 3' 89 112 38 6 171 - - - - 5.75 2.6 009M2QT" 1 25 16 425 51/2 140 3 76 2 64 91/2 241 - - - - 12.25 5.6 009M2QT" 1 32 17 441 6 150 31/2 89 212 64 11 3 /8 289 - - - - 14.62 6.6 009M2QT* 1 40 171/4 454 6 150 31/2 89 21h 64 11'/8 283 - - - - 16.32 7.4 009M2QT* 2 50 21% 543 7 197 41/2 114 31/4 83 13'/ 343 - - - - 30.00 13.6 0090T -S 14 8 10 250 6 150 3 86 114 32 51/2 140 2 60 212 64 5.50 2.5 0090T -S 3 /s 10 10 250 6 150 3 86 11/4 32 512 140 2% 60 2'/ 64 5.50 2.5 009QT -S 12 15 10 250 6 150 3 86 114 32 512 140 2 70 214 57 5.50 2.5 009M3QT -S 3 /4 20 10 273 614 159 3 89 112 38 6 171 3 81 2 70 7.75 3.5 009M2QT -S 1 25 16 425 7 197 3 76 2 64 9 241 3 95 3 76 15.25 6.9 009M2QT -S 1'/4 32 17 441 7 197 31/ 89 2 64 11%8 289 4'/16 113 312 89 20.19 9.2 009M2QT -S 1' 40 17 454 7 197 31/2 89 21/2 64 1118 283 41/4 124 4 102 20.32 9.3 009M20T -S 2 50 21 543 81/4 210 41/2 114 314 83 13'% 343 5 151 5 127 36.87 16.7 MODEL SIZE DN in. mm in. A mm in. C mm in. I DIMENSIONS D mm (APPROX E in. mm .) in. I L mm I in. I . R mm in. U mm WEIGHT lbs. kgs. 009LF 2 65 - - - - 4 114 - - 18% 460 - - 10 270 76 34.5 0090SY 2 65 331/4 845 151/4 403 4% 114 16 416 18 460 7 197 10% 270 166 75.3 009NRS 2 65 331/4 845 11% 289 41/2 114 16 416 18 460 7 197 10%s 270 161 73.0 0090T 21/2 65 33'/4 845 6 152 4' 114 16 416 18'/e 460 7 197 10% 270 150 68.0 009LF 3 80 - - - - 4'% 114 - - 18 460 - - 10 270 76 34.5 0090SY 3 80 34 870 181/2 470 41/2 114 16 422 1816 460 8 222 10% 270 198 89,8 009NRS 3 80 34 870 12 324 41/2 114 16 422 18 460 8 222 10% 270 191 86.6 009QT 3 80 34 870 7 178 4 114 16 422 18 460 8% 222 10 270 158 71.7 Dimensions and Weight: 1/4" - 2 rr (8 - 50mm) 009 Suffix HC - Fire Hydrant Fittings dimension `A = 25 (637mm) '• Approved by the Foundation for Cross - Connection Control and Hydraulic Research at the University of Southem Califomia. Dimensions and Weight: 2 and 3" (65 and 80mm) 009 { I C open STRAINER SIZE DIMENSIONS'(appro .) WEIGHT M mm 10 254 N in. mm 6'f 165 Nit in. mm 9 248 2 in. mm 2'/ 65 3 80 10'/8 257 tClearance for servicing Ibs. kgs. 8 12,7 7 178 10 254 34 15.4 Watts G -4000 Series QT - Ball Valves Capacity Performance as established by an independent testing laboratory. 1 /a" (8mm) 009QT kPa psi 138 20 117 17 96 14 76 1 55 8 35 5 AP kPa psi 138 20 117 17 96 14 76 11 55 8 35 5 AP 0 kPa psi 172 25 138 20 103 15 69 10 35 5 AP0 kPa psi 207 30 165 24 124 18 83 12 41 6 0 0 0 2 AP 07.6 kPa psi 207 30 172 25 138 20 103 15 69 10 35 5 0 0 AP 0 ES -009 0325 .25 .60 .75 3/4" (10mm) 009QT '/z" (15mm) 009QT * 2.5 5 7.5 10 3 8 9 5 19 28.5 38 47.5 5 7.5 1.5 2.3 3/4" (20mm) 009M3QT * 12.5 1.17 .95 1.9 2.9 3 8 4.5 .25 .50 .75 1.25 1.50 25 3.1 gpm .95 1.9 2.9 3.8 4.8 5.7 9.4 11.8 1pm 15 gpm 57 Ipm 15 fps 4.6 mps 6 10 14 18 22 26 30 34 38 42 46 gpm 23 38 53 68 84 99 114 129 144 160 175 1pm 7.5 15 fps 2.3 4.6 mps 1" (25mm) 009M2QT 5 10 20 30 40 50 60 70 80 gpm 19 38 76 114 152 190 228 266 304 Ipm 7.5 15 fps 2.3 4.6 mps *Typical maximum system flow rate (7.5 feet/sec., 2.3 meters/sec.) 1' /" (32mm) 009M2QT kPa psi 172 25 138 20 103 15 69 10 35 5 gpm 0 0 Ipm AP 0 0 kPa psi 207 30 172 25 138 20 103 15 69 10 35 5 0 0 AP O 0 kPa psi 207 30 172 25 138 20 103 15 69 10 35 5 0 0 AP 0 20 0 76 kPa psi 172 25 138 20 103 15 69 10 35 5 0 0 AP 0 kPa psi 172 25 138 20 103 15 69 10 35 5 0 0 © Watts Regulator Co., 2002 10 20 30 40 50 38 76 114 152 190 5 7.5 10 1.5 2.3 3.0 11/2" (40mm) 009M2QT 10 20 30 40 50 60 70 80 90 100 110 120 gpm 38 76 1 4 152 190 228 266 304 342 380 418 456 Ipm 5 7.5 10 15 fps 1.5 2.3 3.0 4.6 mps 40 60 152 228 5 1.5 2" (50* mm) 009M2QT 70 228 266 15 4.6 60 80 gpm 304 Ipm fps mps 80 100 120 140 160 180 200 gpm 304 380 456 532 608 684 760 1pm 7.5 10 15 fps 2.3 3.0 4.6 mps 21/2"(65mm) 009 25 50 75 100 125 150 175 200 225 250 gpm 05 10- 295 380 475 570 665 760 885 950 Ipm 5 7.5 10 15 fps 1.5 2.3 3.0 4.6 mps 3" (80mm) 009 0 25 50 75 100 125 150 175 200 225 250 275 300 325 gpm AP 0 95 190 285 380 475 570 665 760 855 950 1045 11401235 Ipm 5 7.5 10 fps 1.5 2.3 3.0 mps Printed in U.S.A. Jun. 22. 2009 3:37AM REVIEWED FOR CODE COMP APPROVED JUN 2 6 2009 `iacrrrP S /919 coon= here Wads du or pstriallon. Conedt factory melding eseepscdeu or COMPARE THESE FEATURES • Durable Cast Iron construction. • Model 140 features a Non - Clogging engineered them* plastic vortex impeller design and passes W spherical solids. • Model 145 features an engineered thermoplastic single vane lmpeler design end passes % ephericei solds. • Motor - 60 Hz, 345D RPM, oB- filled, hermetically sealed, automatic reset, thermal overload protected. • Available In both single or double shalt seal designs. • Carbon/Ceramic seats. • Assembled with Stainless Steel bolts. • Upper sleeve and lower bail bearing running in bath of ail. • 20 ft UL Listed Neoprene card with molded plug cap and ground win:. • 1W NPT vertical discharge. • Stainless steel llftMg handle. • BN and SE models tnciude a variable level float switch and 114 X T PVC adapter ?Hong. • Operates at temperatures to 1301 (54•C) in effluent or dewalining applicsions. • Conoslon resistant powder coated epoxy finish. Note: The sizing of effluent systems normally requires variable level flogs) controls and property sized basins to rr..hteve required pumping cycles or dosing timers with nonautomatic pumps. PUMP [11 MML TO: P.Q BOX 16341 City of Tukwila L&, KY 40?56�T4r STOP TD: 3649 r.'anBltrar Road BUILDING DIVISIOl ; '" S2g-MP • MX (502) '74-3624 Manddelhnets of.. . RE !. ?`L: ,a„ow S /.9 ' ' JUN 2b2009 TUKWILA PUBLIC WORKS Ferguson WOODINVILl- PLUMBING No.9718 P. NAIL TO O. BOX 1634?• Whet KY 4028611347 SHIP TO: 3649 Cane Run Road • Louisville. KY 402f1 -1961 x502) 178.2731- 1 (10x) 9284 • FAX (0021 ?14.3624 140/4140 8145/4145 Cast Iron Series (For Pump Prefix identification see News & Views 0052) "FL Y Y FOR SEPT1C TANK - LOW PRESSURE PIPE (LPP) AND ENHANCED FLOW STEP SYSTEMS EFFLUENT OR DEWATERING PUMPS SUBMERSIBLE 1W' NPT DISCHARGE ; POWDER COATED le �per■oee MODELS AVAILABLE • Marea6c (Models SS IL Sp • I HP or UV (14014140) - cc HP, 1Ph 1151► 04514146) Madat 0N140 and BN74S Single Seal Pumps Model 4140 and 4149 Double Seal Pumps Iwo Model 140 and 145 Single Seer Pumps 11YOFT JUN 2 3 PERMIT CE CO Copyright 2008 Zoeller Co. Al rights reserved. CORRECTION LTR# FILE COPY • 1 visit our web site: www.soeller.com SECTION: 2.20.045 FlWi1592 12116 Superset 0305 MLA 1110 9TER ocz 14014140 & 14514145 MODELS Control Selection Model Model Volts - Ph Mode Amps Simplex Duplex 141'40 E140 1144110 ? Ma LNb : 12.0' _1 ..or 2 ' 3 E4140 230 1 Non 6 .0 ' 1 or2 3 BN140 BN4140 115 1 Auto 12.0 ' — 1E140 13E4140 230 1 Auto 5.0 ' _ — N145 N4145 115 1 Non 13.0 1 or 2 3 BN145 BN4145 115 1 Auto 13,0 • — Jun. 22. 2009 3:3BAM Ferguson W0001NVItl— PLUMBING a u MAP P2121omAtacECURVE swami 01014Or112414S >. . • >r� • 1• • v MOO w ✓ ~ umr • m NDerErleeNTE TOTAL DYNAMIC HEAD/FLOW PER MINUTE EFFLUENTAND DEWATERING Awl '651100 W SO so 48 45 171 os 155 80 10 01 umma0 MADEI ha Man 15,01147 X108 °• `to °" 19 15 42 28 30 40 so 6.1 7.5 4.1 122 112 60 102 MU MVMeot 14014140 14514145 m CONSULT FACTORY FOR SPECIAL APPLICATIONS • Electrical alternators, for duplex systems, are available end supplied wllh an alarm. • Mechanical alternators, for duplex systems. are available with or without alarms. • Control alarm systems ere available for 1 phase pumps used in simplex system. Sae FM0732. • variable level control switches we amiable for oontroUiing single phase systems. • Double piggyback variable level Bost switches are available brvadabte level long cycle controls. • Sealed Qwik -Box available for outdoor installations. See FM1420. • Refer to FM0506 for applications above 130°F (54'C). 'Single piggyback switch Included. OPTIONAL PUMP STAND PIN 104213 • Reduces potential clogging by deists • Replaces rocks or bride under the pump. • Made of durable, noncorrosive ABS. • Raises pump r Off bottom of basin. • Provides the abirdy b raise intake by adding sectors of 114' or 2' PVC piping. • Attaches securely b pump. • Aocommodaws sump, dewatsdng and Cued applications. NOTE: Vide Sure neat is free from obstruction. SELECTION GUIDE 1. For autometic use single piggyback variable level float switch or double piggyback variable level Boat winch. Refer to FM0477. 2. See FM1228 for sorest model of simplex control panel. 3. See FM0712 for correct model of duplex control panel. RESERVE POWERED DESIGN For unusual conditions a reserve safety factor Is engineered into the design of every Zoeller pump. 0 Copyright 2000 Zoaner Co. AS rights reserved. No. 9118 P. 2 Sd91■>Se21 DES∎gn Weiyhl a?, Ib5. II Douala Seal OW inn thicighl 63 1b5. 48105140adon alcontalLMOtao4444cmand M0 801 • sedans 8b ',stirad rsanpd aecUkIII . AO dadrioal and ,e.1y mesa Mould be rolio•ed bWudim me gaL1 nceM Nbiaud Mao Cade (NEC) and the Oeeype50aa 9e1Ely add Mato Ant AVM. MODEL 140/4140 145/4145 Fe31 Me's Gal. liters Gel' - Ut91s 4A . ;;;114C:. M ._48 01 : - 232 10 3.0 50 303 50 .B 15 4.6 73 TJfi 56 213 !; 20 (1 66 250 53 201 25 7,6 49 223 49 186 30 9.1 49 105 45 , 171 40 12.2 28 106 35 933 50 15.2 — -- 26 99 60 _ 11.3 •- 16 e1 $h,q�ot Head. 503052V 741(T2k0 Jun. 22. 2009 3:38AM Ferguson WOODINVIll—PlUMBING No. 9718 P. 4 Zoeller Pump Company Page 1 of l Total Dynamic I-lead /Flow Per Minute http : / /www.zoellerpumps. corn/ ImageDisplay. aspx ?ProductID= 94&ImageName=72tdh1 6/22/2009 Jun. 22. 2009 3:38AM Ferguson W000INVILL— PLUMBING No. 9718 P. 3 Zoeller k'ump Company Page 1 of 1 Pump Performance Curve Models 140/4140, 145, 4145 IS http: / /www. zoellerpumps. cotta/ lmageDisplay. aspx ?Product1D= 94&ImageName72curve 1 6/22/2009 4;/E. Zi -oz*s Joe Primm From: Sent: To: Go: Subject: Attachments: Christine Johnson Wednesday. June 10.2009 4:18 PM Joe Primm Benjamin Parker FW: Rainier industries x18435 Olympic Ave S PGO9 052 Joanna Spar car.vct From: Joanna Spencer [maiRo:jspencer@d.tukw0a.wa.us) Sent: Wednesday, June 10, 2009 4:16 PM To: Christine Johnson Subject Rainier Industries 018435 Olympic Ave 5 PG09 -052 Christine - L / • 1) Please clarify: b the proposed RPPA Installed b In -can ns or /'i - r r?; Uhl ��riic'.�rerJ for Premise Isolation. 2) Premise isolation is required by Gty cross- connection program. Domestic water RPPA for premise isolation sha0 be Installed outside the building In a freeze protection enclosure downstream of the existing domestic water meter, located In a planting strip. A separate PW Type C construction permit is n quired. PW wO send a letter to the building owner addressing this requirement. 3) Is the grey water being pumped now or does R need to be pumped es a result of the 0. 4)Row muds waste b being generated ? Call out says please clarify what are we connectconnecting. rmeng. 5) Label oven location on plan. s�F L/ . Dr/ ar t/ Joanna Spencer Development Engineer City of Tukwila Public Works Department 6300 Southcenter BI d., Suite 100 Tukwila, WA 98188 -2544 phone: 206-431-2440 fax: 206431 -3665 tch oven Installation? *OMSK GA- A9/C4 „ �iyS.rU i vi "connect _Lo existing 4" waste; ertG 14,/,/ /CMG IT �h 0 aaretSFITaeG(U C nniotti da"4/ W4rel; sce/f r U O P 1 / RA S & L 1. iM 4, 471O -7D #M"‘" 0 �!!/! LU4ra //b vr S .I y +` Cht<e- Q ),' 4( (4x) AM.& Dfi C6n"eca1 7D 4 70' 4 zee” a ,u 7//v /d i /cur15 d CJ �nS // a¢y, w LU Qom® — c u- W o W2O co 8 c" ft CC8 w J [ 0 tag 5 caE >p M m N �O = U 0 w 0$ / W �yC CC C O U J IfX Joe Primm From: ) Sent: To: Subject: From: Russell Clegg [mailto:russellc @rainier.com] Sent: Friday, June 19, 2009 4:07 PM To: 'jr @finishingequipment.com' Cc: Brian Rowinski; David Taquino Subject: Existing Natural Gas Equipment Rainier Industries Good afternoon JR, This is a list of existing equipment at our facility that uses natural gas. RTU# 1 Lennox 5GA 480S2 input BTU 500,000 Total RTU# 2 Lennox TGA 180S2BM input BTU 360,000 IR 1 Space Ray infrared heater LTU 225 -50N5 input BTU 250,000 (total 8 units) IR 2 Space Ray infrared heater LTU 175 -40N5 input BTU 175,000 (total 1 lunits) If I can provide any additional information please call my cell @ (206) 228 -5500 Russell JR Rogers [finishingequipment @msn.com] Monday, June 22, 2009 8:10 AM Joe Primm FW: Existing Natural Gas Equipment Rainier Industries 1 IF]LE COPY REVIEWED FOR CODE COMPLIANC APPROVED JUN 2 6 2009 City of Tukwila BUILDING DIVISION RECEIVED JUN 2 5 2009 TUKWILA PUBLIC WORKS RECEIVED CITY OF TUKWILA JUN 2 3 2009 PERMIT CENTER CORRECTION LTR# 1 - Joe Primm From: JR Rogers [finishingequipment @msn.com] Sent: Monday, June 22, 2009 9:03 AM To: Joe Primm Subject: FW: Existing Natural Gas Equipment Rainier Industries Here is the additional data. The meter is American Meter AL 2300 Rated for 5,000 CFH @ 2PSI The oven uses 2,100 MBTU @ 7" W.C. If you add up the total BTU of the equipment below and add the oven the total is 6,885,000 BTU From: Russell Clegg [mailto:russellc @rainier.com] Sent: Friday, June 19, 2009 4:07 PM To: 'jr @finishingequipment.com' Cc: Brian Rowinski; David Taquino Subject: Existing Natural Gas Equipment Rainier Industries Good afternoon JR, This is a list of existing equipment at our facility that uses natural gas. RTU# 1 Lennox 5GA 480S2 input BTU 500,000 Total RTU# 2 Lennox TGA 180S2BM input BTU 360,000 IR 1 Space Ray infrared heater LTU 225 -50N5 input BTU 250,000 (total 8 units) IR 2 Space Ray infrared heater LTU 175 -40N5 input BTU 175,000 (total 11 units) If I can provide any additional information please call my cell @ (206) 228 -5500 Russell Joe Primm , From: Sent: To: Subject: Attachments: Attached is the pumps specs. Hope this helps. SCAN-4987_000 JR Rogers [finishingequipment @msn.com] Monday, June 22, 2009 2:24 PM Joe Primm FW: Emailing: SCAN - 4987_000 SCAN- 4987_000.pdf Based upon the pipe size, head pressure and distance it will flow up tQ 10 gpm. The pressure washer flows a max of 4 gpm. A float -will turn Qn. pFf OA4s.ump pump .when- the level rises about 9" i the 3' cubic sump", Not 'mu h Original Message From: Alisa Betts [mailto:alisab @indair.net] Sent: Monday, June 22, 2009 2:13 PM To: jr @finishingequipment.com Subject: Emailing: SCAN - 4987_000 The message is ready to be sent with the following file or link attachments: Note: To protect against computer viruses, e-mail programs may prevent sending or receiving certain types of file attachments. Check your e-mail security settings to determine how attachments are handled. Joanna Spencer - RE: Re: Rainier Industries @18435 Olympic Ave S PG09 -052 From: To: Date: Subject: CC: Attachments: Joanna, "JR Rogers" "'Joanna Spencer ' , "Dave 06/29/2009 9:11 AM RE: Re: Rainier Industries "'Joe Primm "' , "'Joe Primm "" , Haberman" , 3 71 - @18435 Olympic Ave S PG09 -052 Page 1 of 3 Attached it the King County Metro Industrial Waste Water discharge application what we have submitted for Rainier Industries. Our King County contact for this permit is Mr. Dave Haberman, he is fully aware of the project and was on site this last week for a preliminary inspection. Dave is currently waiting for us to complete the installation of the equipment and plumbing do he can proceed with the issuance of their permit. Please let me know if you have any further questions. Best Regards J.R. Rogers Finishing Equipment NW Div. Industrial Air Systems Inc 17739 15th Ave NE Shoreline WA 98155 Cell 425 - 754 -3934 Office 206 - 363 -0119 This transmission and the information contained in it is privilege and confidential and is intended only for the use of the individual named above. If the reader of this message is not the addressee, you are hereby notified that any review, use, dissemination, distribution, or coping of this transmission or its contents is strictly prohibited. From: Joe Primm [ mailto :JoePrimm @AuburnMechanical.com] Sent: Monday, June 29, 2009 8:38 AM P4 0 9- asz file: / /C:\Documents and Settings \joanna.TUKWILA\Local Settings \Temp\XPgrpwise \4A... 06/29/2009 To: jr @finishingequipment.com Subject: FW: Re: Rainier Industries @18435 Olympic Ave S PG09 -052 JR, here is another snag on Rainier Industries. Would you mind calling the Arnauld Girard at 206- 263 -3012 and get his approval? He may ask what is in the gray water and you would no more than me on this. Thanks Joe Primm From: Christine Johnson Sent: Monday, June 29, 2009 8:34 AM To: Joe Primm; Joe Holden Cc: Benjamin Parker Subject: FW: Re: Rainier Industries @18435 Olympic Ave S PG09 -052 From: Joanna Spencer [mailto :jspencer @ci.tukwila.wa.us] Sent: Friday, June 26, 2009 11:05 AM To: Christine Johnson Subject: Fwd: Re: Rainier Industries @18435 Olympic Ave S PG09 -052 Christine, Would you please contact KC Industrial Waste, Mr Arnauld Girard @ 206 263 -3012 for Authorization approval to discharge grey water from the batch oven to sanitary sewer. Submit a copy of authorization approval letter to PW. Thanks, Joanna Spencer Development Engineer City of Tukwila Public Works Department 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 -2544 phone: 206 - 431 -2440 fax: 206 - 431 -3665 jspencer @ci.tukwila.wa.us »> Joanna Spencer 06/11/2009 9:10 AM »> Thank you Christine. Joanna Page 2 of 3 »> "Christine Johnson" <ChristineJohnson @AuburnMechanical.com> 06/11/2009 8:21 AM »> Joanna, Please see the attached comments regarding permit number PG09 -052. Please let mek know if you have file: / /C:\Documents and Settings \j oanna.TUKWILA\Local Settings \Temp\XPgrpwise \4A... 06/29/2009 any questions. Thank you, Joe Christine Johnson 1 Project Engineer 1 Auburn Mechanical 1P 253.838.97801F 253.929.1426 1 www.auburnmechanical.com From: Joe Primm Sent: Thursday, June 11, 2009 7:48 AM To: Christine Johnson Subject: FW: Message from KMBT_C451 When Performance Counts Page 3 of 3 Here are the corrections for City of Tukwila, see if this will work ok? Line item #2 Premise Isolation. This is not in our scope. The work is all inside building. From: copier @auburnmechanical.com [mailto :copier @auburnmechanical.com] Sent: Thursday, June 11, 2009 12:46 AM To: Joe Primm Subject: Message from KMBT_C451 file: / /C:\Documents and Settings \joanna.TUKWILA\Local Settings \Temp\XPgrpwise \4A... 06/29/2009 ESICOMES IlfaMERESAFICaSLOVIC Industrial Waste Program Wastewater Discharge Permit Application King County Department of Natural Resources and Parks Wastewater Treatment Division PG0S-062 PRIMARY PERSON TO BE CONTACTED ABOUT THIS J.R. Rogers APPLICATION: Sales/ Engineering Name 17739 15` Ave NE BUSINESS MAILING ADDRESS: 18375 Olympic Ave S Title (e.g., President, Consultant, On -Site Manager) (425) 754 -3934 Mailing Address Seattle, WA 98155 Telephone No. (425) 754 -3934 City, State jr @finishingequipment.com Zip Code 24 -Hour Emergency Phone No. (206) 206 -129 E -Mail Address Zip Code FAX No. SECONDARY PERSON TO BE CONTACTED ABOUT THIS Brian Rowinski APPLICATION: VP Name 18375 Olympic Ave S BUSINESS MAILING ADDRESS: 18375 Olympic Ave S Title (e.g., President, Consultant, On -Site Manager) (425) 251 -1800 Mailing Address Tukwila, WA 98188 Telephone No. (206) 423 -2735 City, State brianrArainier.com Zip Code 24 -Hour Emergency Phone No. (425) 251 -5065 APPLICANT BUSINESS AND /OR PROJECT NAME: Rainier Industries Ltd. ADDRESS OF SITE DISCHARGING WASTEWATER: (If no address, indicate cross streets.) 18375 Olympic Ave S BUSINESS MAILING ADDRESS: 18375 Olympic Ave S Site Address Seattle, WA 98188 Mailing Address Seattle, WA 98188 City, State Zip Code City, State Zip Code You will find detailed instructions for completing each section of this application and each required exhibit in the enclosed packet, "Wastewater Discharge Permit Application Instructions and Guidelines." Review the entire application and instruction packet carefully before completing any part of the application. • Submit one application for each site. • King County Industrial Waste (KCIW) does not require an application fee. Once KCIW determines that you require a permit, KCIW will bill you prior to issuing you a draft permit, • Answer all questions and include the required exhibits. Incomplete applications will be returned to you. • If you do not have an answer for the requested information, indicate so and explain why. • Indicate "N /A" if a section does not apply to your operations. • Use additional pages, if needed. • Send three copies of the completed application and exhibits to: .113 King County Industrial Waste 130 Nickerson Street, Suite 200 Seattle, WA 98109 -1658 King County Wastewater Discharge Permit Application Business Activity ' Type of Product or Brand Name Daily Quantities Average Maximum Various Products Wave Guide 8 24 E -Mail Address I FAX No. 1. NATURE OF BUSINESS Briefly describe your business and the main activities producing wastewater at the applicant site (type of processing, manufacturing, service, remediation). Manufature of of various products. This is being installed specifially for aluminum parts. The parts are to be cleaned in a manual wash booth prior to powder coating them. Attached is a Doc showing the proposed wash system. 2. PERTINENT IDENTIFICATION NUMBERS AND PERMITS Standard Industrial Classification (SIC) 2394' EPA WAD No. Water /Sewer Agency City of Tukwila and Account No. 15 - 0140 - 0000 Water Meter No(s). 680066430 & 69207595 Current King County Permit No. Date Business Started at this Site 07/08 Environmental Control Permits Issued for Applicant Site: 1. DAILY AND SEASONAL VARIATIONS Average Number of Operating <; Days /Year 254 303 Circle Days You General y Discharge and Provide Number of Hours Discharging on Those Days Mon 2 12 Tue 2 12 Wed 2 12 Thur 2 12 Fri 2 12 Sat 2 12 Sun Holiday Number of mployees /Shift Day 120 120 Night Swing 2. BUSINESS ACTIVITIES AND PRODUCTS Business activities include manufacturing, processing, and remediation activities. King County Wastewater Discharge Permit Application Brand Name Chemical or Actual Name Purpose Daily Quantities Used Tank Volume n - Average Maximum Coral Chemical Flash Clene 1414 Alkaline Cleaner Clean the parts 20 Gallons 30 55 3% Coral Chemical pH Minus Buffer discharge prior to pumping to drain 1.5 3 55 .5 3. RAW MATERIALS AND CHEMICALS USED IN THE PROCESS 4. INDUSTRIAL WASTEWATERS DISCHARGED TO KING COUNTY SEWERS (1) Enter a brief description and assign a number for each process (add more lines if necessary). Also show these process numbers in Exhibits A and B. (2) Indicate frequency of discharge; either continuously discharged when generated, or stored and discharged in batches. Process Number 1 2 Process That Generates Wastewater Pressure Washing of Parts Rinse Substances Discharged to the Sewer Alkaline Cleaner & water Rinse Water Type of Pretreatment Cleaning Rinse Frequency o Discharge' (Continuous or batch) Continuous thought the day Continuous thought the day Daily Quantity Discharged In Gallons Average 960 400 Maximum 2500 1000 5. LIQUID WASTES AND SLUDGES REMOVED BY MEANS OTHER THAN KING COUNTY SEWERS Enter annual, monthly, or daily volume, or volume of each removal. Indicate unit of measurement. Type of Waste /Substance Means of Removal Frequency Volume King County Wastewater Discharge Permit Application King County Wastewater Discharge Permit Application . ill �lj .V :iLuk :Y'iR`•* `SxTIL'A�i: ?+ SG9 Type of Consumption /Discharge . Water In: Water Out: Water Use Water Discharge or Loss Water Source (1) Average (gals /day) Maximum (gals /daY) Discharge Point (2) Average (gals /day) Maximum (gals /day) Industrial processing water /wastewater a 1360 4800 a 1250 4800 Contact cooling water Non - contact cooling water Boiler and cooling tower feed /blowdown Water incorporated into product Sanitary water /wastewater a 3,125 4000 a 3,125 4000 Industrial storm water Plant washing water /wastewater a 50 100 a 50 100 Construction dewatering Groundwater remediation Site Irrigation Evaporation — — Other: (please indicate) TOTALS: — 4535 8,900 — 4,425 8,900 R BALANCE TABLE ter the appropriate letter for the water source: City Service b.) Private Well c.) Reclaimed Water d.) Raw Materials e.) Industrial Storm Water f.) Groundwater (2) Enter the appropriate letter for the discharge point: a.) Sewer b.) Storm Drain c.) Receiving Water d.) Waste Hauler e.) Evaporation f.) Product If the discharge is entering the sewer, also indicate the side sewer (ss) number, if available. You must provide documentation of the water balance calculations provided in this table. (See directions for Exhibit I.) (3) King County Wastewater Discharge Permit Application .. + 's.433k:ipic.101414!1OCIA , .MINI : w a = r�.iA7* e9e= • SaaggiffaBerP SitSEZEIEitaft 6. PROPOSED DURATION OF WASTEWATER DISCHARGE: 10 years King County Wastewater Discharge Permit Application ttii rM .x Please see instructions for information on how to complete the following exhibits: 61113724T"' nriti Ws] iniCERGEESKISIBAIMMESSMMERMIEEMMILA Exhibit A: Schematic Flow Diagram (required) Exhibit B: Site Layout (required) Exhibit C: Planned Changes in Pretreatment or Waste Disposal Practices Exhibit D: Analytical or Historical Data Exhibit E: Spill Prevention and Containment Plan Exhibit F: Tank Capacities and Concentrations Exhibit G: Hydrogeologic Reports for Groundwater Remediation Exhibit H: Engineering Report (Required only if you have wastewater pretreatment systems or are intending to install such systems.) Exhibit 1: Documentation of Water Balance Calculations 5 I certify under penalty of law that this document and all attachments were prepared under my direction or supervision in accordance with a system designed to ensure that qualified personnel properly gather and evaluate the information submitted. Based on my inquiry of the person or persons who manage the system, or those persons directly responsible for gathering the information, the information submitted is to the best of my knowledge and belief, true, accurate, and complete. I am aware that there are significant penalties for submitting false information, including the possibility of fine and imprisonment for knowing violations. J.R. Rogers Printed Name Sales Egnineerinq Title Signature Date This information is available in alternative formats for people with disabilities on request at 206 - 263 -3000 (voice) or 711 (TTY). King County Wastewater Discharge Permit Application Auburn "Mechanical City of Tukwila 6300 Southcenter Blvd Suite #100 Tukwila, Wa 981 Re: Permit Application # PG09 -052 Building Division Review Memo answers Project Name: Rainier Industries June 22nd 2009 • Gas Piping for building is feed by American Meter AL 2300 rated 5,000 CFH@ 2 PSI Existing service has RTU #1 Lennox 500,000BTU RTU #2 Lennox 360,000 BTU Space heater 250,000 BTU (total 8 units) Space heater 175,000 BTU (total 11 units) New Batch oven being installed @ 2,1000 BTU @ 7" W.C. = for entire building 6,885,000 BTU is feed from our 2 "PSI meter • Length of gas service from Meter to batch oven is 200ft • Sump pump specs is enclosed in this letter • Water supply to the wash booth is now drawn on drawings. • Isometric drawing is provided, showing how we plan on doing our connections to both its sump pump and over to our Point of connection at sewer line by bathroom area. AUBURN MECHANICAL, INC. Thank you, Joe Primm Service Plumbing Superintendant (253) 838 -9780 www auburnmechanical.com 2623 West Valley Highway North P.O. Box 249 Auburn, Washington 98071 P 253.838.9780 v June 17, 2009 Christine Johnson PO Box 249 Auburn, WA 98071 Dear Ms. Johnson, • CiofTu Department of Community Development RE: CORRECTION LETTER #1 Plumbing /Gas Piping Permit Application Number PG09 -052 Rainier Industries — 18435 Olympic Ave S This letter is to inform you of corrections that must be addressed before your plumbing /gas piping permit(s) can be approved. All correction requests from each department must be addressed at the same time and reflected on your drawings. I have enclosed comments from the Building and Public Works Departments. Building Department: Dave Larson, at 206 431 -3678, if you have questions regarding the attached memo. Public Works Department: Joanna Spencer at 206 431 -2440 if you have questions regarding the attached memo. Please address the attached comments in an itemized format with applicable revised plans, specifications, and /or other documentation. The City requires that two (2) complete sets of revised plans, specifications and /or other documentation be resubmitted with the appropriate revision block. In order to better expedite your resubmittal, a `Revision Submittal Sheet' must accompany every resubmittal. I have enclosed one for your convenience. Corrections /revisions must be made in person and will not be accepted through the mail or by a messenger service. If you have any questions, please contact me at (206) 431 -3670. Bill Rambo Permit Technician encl File: PG09 -052 W:\Permit Center\Correction Letters \2009\PG09 -052 Correction Letter #1.DOC wer Jim Haggerton, Mayor Jack Pace, Director 6300 Southcenter Boulevard, Suite #100 0 Tukwila, Washington 98188 0 Phone: 206- 431 -3670 0 Fax: 206 - 431 -3665 Budding Division Review Memo • 0 Date: June 8, 2009 Project Name: Rainier Industries Permit #: PG08 -052 Plan Review: Dave Larson, Senior Plans Examiner Tukwila Building D ivision Dave Larson, Senior Plan Examiner The Building Division conducted a plan review on the subject permit application. Please address the following comments in an itemized format with revised plans, specifications and/or other applicable documentation. (GENERAL NOTE) PLAN SUBMITTALS: (Min. size 11x17 to maximum size of 24x36; all sheets shall be the same size). (If applicable) Structural Drawings and structural calculations sheets shall be original signed wet stamped, not copied.) 1. Please provide gas pipe sizing information. Total BTU load on 3 inch main line from meter, including new and existing equipment, gas pressure, and the length of pipe from the meter to the new powder coat oven. 2. The water supply and gray water return to the sanitary sewer is shown on the plans as connecting to the powder coat oven. Was this supposed to be for the wash booth. Please revise plans or verify that this is correct as shown. 3. Please provide pump specs for gray water sump. Should there be questions concerning the above requirements, contact the Building Division at 206 -431- 3670. No further comments at this time. DATE: June 16, 2009 PROJECT: Rainier Industries 18435 Olympic Ave S PERMIT NO: PG09 -052 PLAN REVIEWER: Contact Joanna Spencer (206) 431 -2440 if you have any questions regarding the following comments. 1) On your plan clearly label location of proposed batch oven and pipe material for 1" pumped grey water. 2) Provide a brief narrative of subject grey water characteristics, and obtain an Authorization to Discharge to Sanitary Sewer from the King County Industrial Waste Division, if required. Please contact Mr. Arnaud J. Girard, Industrial Waste Investigator at (206) 263 -3012 to start the process. A copy of Industrial Waste Permit or discharge approval letter shall be submitted to Public Works. 3) Submit specifications and cut sheet for the proposed pump. 4) Add a detail showing how and where this pump will be installed. 5) The City has determined that the building has deficiencies on the domestic water service. A Reduced Pressure Principle Assembly (RPPA) shall be installed immediately downstream of the permanent Water Meter for premise isolation. Installation at another location requires the Public Works Director's approval. The RPPA shall be installed in a Hot Box/Rock or equal freeze protection enclosure anchored into a minimum 4" thick concrete pad. A separate letter was mailed to the property owner, Access Road Partners LLC addressing premise isolation requirement. P: Joanna/PG09 -052 • 1 PUBLIC WORKS DEPARTMENT COMMENTS DATE: June 10, 2009 PROJECT: Rainier Industries 18435 Olympic Ave S PERMIT NO: PG09 -052 PLAN REVIEWER: Contact Joanna Spencer (206) 431 -2440 if you have any questions regarding the following comments. 1) Please revise your plans per June 10, 2009 e-mail copied below: From: Joanna Spencer To: Christine @auburnmechanical.com Date: 06/10/2009 4:16 PM Subject: Rainier Industries @18435 Olympic Ave S PG09 -052 Attachments: Joanna Spencer.vcf Christine - 1) Please clarify: is the proposed RPPA installed for in- premise or for premise isolation. 2) Premise isolation is required by City cross -connection program. Domestic water RPPA for premise isolation shall be installed outside the building in a freeze protection enclosure downstream of the existing domestic water meter, located in a planting strip. A separate PW Type C construction permit is required. PW will send a letter to the building owner addressing this requirement. 3) Is the grey water being pumped now or does it need to be pumped as a result of the batch oven installation? 4)How much waste is being generated ? Call out says "connect to existing 4" waste "; please clarify what are we connecting. 5) Label oven location on plan. Joanna Spencer Development Engineer City of Tukwila Public Works Department 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 -2544 phone: 206 -431 -2440 fax: 206 - 431 -3665 jspencerOci.tukwila.wa. us P: joanna/comments 1 PG09 -0524 • 0 PUBLIC WORKS DEPARTMENT COMMENTS ACTIVITY NUMBER: PG09 -052 DATE: 06 -23 -09 PROJECT NAME: RAINIER INDUSTRIES SITE ADDRESS: OLYMPIC AV S Original Plan Submittal Response to Incomplete Letter # X Response to Correction Letter # 1 Revision # After Permit Issued DEPARTMENTS: &ini sion te Public Wbrks C Complete C Comments: DETERMINATION OF COMPLETENESS: (Tues., Thurs.) APPROVALS OR CORRECTIONS: Documents/routing slip.doc 2 -28 -02 � PERMIT COORD COPS PLAN REVIEW/ROUTING SHIP Fire Prevention Structural Incomplete Approved n Approved with Conditions Notation: REVIEWER'S INITIALS: DATE: DATE: Planning Division Permit Coordinator DUE DATE: 06-25-09 Not Applicable Permit Center Use Only INCOMPLETE LETTER MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: LETTER OF COMPLETENESS MAILED: TUES /THURS ROUTING: Please Route NI Structural Review Required u No further Review Required n REVIEWER'S INITIALS: DUE DATE: 07-23-09 Not Approved (attach comments) u Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: ACTIVITY NUMBER: PG09 -052 PROJECT NAME: RAINIER INDUSTRIES SITE ADDRESS: 18435 OLYMPIC AVE S X Original Plan Submittal Response to Correction Letter # DATE: 06 -01 -09 Response to Incomplete Letter # Revision # After Permit Issued DEPART ENT DL- 014 Building D'Ivisio �1S Ckpvm Public Works Complete Comments: PLAN REVIEW /ROUTING SLIP DETERMINATION OF COMPLETENESS: (Tues., Thurs.) • Permit Center Use Only INCOMPLETE LETTER MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: LETTER OF COMPLETENESS MAILED: TUES/THURS ROUTING: Please Route 01 Structural Review Required REVIEWER'S INITIALS: APPROVALS OR CORRECTIONS: Documents/routing slip.doc 2 -28 -02 Fire Prevention Structural Incomplete Approved Approved with Conditions Notation: REVIEWER'S INITIALS: DUE DATE: 06-04-09 DATE: DATE: Planning Division Permit Coordinator Not Applicable No further Review Required DUE DATE: 07 -02 -09 Not Approved (attach comments) n Permit Center Use Only l CORRECTION LETTER MAILED: l0 11 Departments issued corrections: Bldg Fire ❑ Ping ❑ PWr Staff Initials: l/ Date: 6/23/2009 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 - 431 -3665 Web site: http: //www.ci.tukwila.wa.us Revision submittals must be submitted in person at the Permit Center. Revisions will not be accepted through the mail, fax, etc. Plan Check/Permit Number: ❑ Response to Incomplete Letter # ® Response to Correction Letter # 1 ❑ Revision # after Permit is Issued ® Revision requested by a City Building Inspector or Plans Examiner Project Name: Rainier Industries \applications\forms- applications on line\revision submittal Created: 8- 13.2004 Revised: PGO9 -052 RECEiver, env of T wun A JUN 2 3 2009 PERMIT CENTER Project Address: 18435 Olympic Avenue South Contact Person: Joe P r i mm Phone Number: 2 0 6 - 7 3 0- 421 I Summary of Revision: Attached are pictures documenting the existence of a premise isolation hot box. Also enclosed are the general notes listed on the building division review memo reviewed by Dave Larson. Items 1 -3 have been addressed and resolved in this document. Sheet Number(s): 1 "Cloud" or highlight all areas of revision including date of revision Received at the City of Tukwila Permit Center by: ❑ Entered in Permits Plus on WJLVA Q \ Bond Bond Company Name Bond Account Number Effective Date Expiration Date Cancel Date Impaired Date Bond Amount Received Date 3 FIDELITY Et DEPOSIT CO OF MD LPM804721809/01/2001 UNUSED Until Cancelled 02/06/2009 ARCHIVED $12,000.0009/12 /2001 2 FIDELITY Et DEPOSIT CO OF MD LPM8047218 09/01/1996 09/01/2001 $6,000.00 1 HARTFORD ACCIDENT Et INDEM CO N5050309 01/01/1984 09/01/1996 09/23/1996 $6,000.00 License Name Type Specialty 1 Specialty 2 Effective Date Expiration Date Status AUBURMI184LA AUBURN MECHANICAL INC CONSTRUCTION CONTRACTOR PLUMBING UNUSED 6/1/19821/1/1984 02/06/2009 ARCHIVED Name Role Effective Date Expiration Date THODAY, DAVID V PRESIDENT 01/01/1980 THODAY, STACY A PRESIDENT 01/01/1980 JOHNSON, KIM SECRETARY 02/06/2009 Untitled Page General /Specialty Contractor A business registered as a construction contractor with LEtI to perform construction work within the scope of its specialty. A General or Specialty construction Contractor must maintain a surety bond or assignment of account and carry general liability insurance. Business and Licensing Information Name Phone Address Suite /Apt. City State Zip County Business Type Parent Company AUBURN MECHANICAL INC 2538389780 PO BOX 249 AUBURN WA 98071 KING Corporation UBI No. Status License No. License Type Effective Date Expiration Date Suspend Date Specialty 1 Specialty 2 600074968 ACTIVE AUBURMI163BA CONSTRUCTION CONTRACTOR 1/1/1984 9/12/2010 GENERAL UNUSED Other Associated Licenses I Business Owner Information Bond Information Insurance Information I 1 • 1 1 1 0 I 1 Page 1 of 2 I https: // fortress .wa.gov /lni/bbip /Detail.aspx 07/02/2009