Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Permit PG09-126 - PACIFIC POWER TECH
PACIFIC POWER TECH 1120 AN OVER PK E EXPIRED 06 -19 -10 PGO9-126 Parcel No.: 2623049098 Address: Suite No: Contact Person: Name: KEN HOVDE Address: PO BOX 24024 , SEATTLE WA Contractor: Name: K MECHANICAL Address: PO BOX 24024 , SEATTLE WA Contractor License No: KMECHML912MP Value of Plumbing /Gas Piping: Fees Collected: 1120 ANDOVER PK E TUKW Plumbing Bathtub or combination bath/shower Bidet Clothes washer, domestic Dental unit, cuspidor Dishwasher, domestic, with independent drain Drinking fountain or water cooler (per head) Food -waste grinder, commercial Floor drain Shower, single head trap Lavatory Wash fountain Receptor, indirect waste Sinks Urinals Water Closet doc: UPC -7/07 Citylif Tukwila Tenant: Name: PACIFIC POWER TECH, LLC Address: 1120 ANDOVER PK E , TUKWILA WA Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http://www.citukwila.wa.us Owner: Name: LEUTHOLD DONALD W Address: 7275 W MERCER WAY , MERCER ISLAND WA $8,740.00 $115.00 I PLUMBING /GAS PIPING PERMIT DESCRIPTION OF WORK: FURNISH AND INSTALL 2" GAS PIPING, VALVES, REGULATORS, SUPPORT HARDWARE, AND PRESSURE TEST. FIXTURE TYPE AND QUANTITY * *continued on next page ** Permit Number: Issue Date: Permit Expires On: Phone: Phone: 206 903 -1100 Phone: 206 903 -1100 Expiration Date: 07/17/2011 PG09 -126 11/02/2009 05/01/2010 Uniform Plumbing Code Edition: 2006 International Fuel Gas Code Edition: 2006 Plumbing (cont.) 0 Building sewer and each trailer park sewer 0 0 Rain water system - per drain (inside bldg) 0 0 Water heater and /or vent 0 0 Industrial waste treatment interceptor, including 0 its trap and vent, except for kitchen type 0 grease interceptors 0 0 Repair or alteration of water piping and/or water 0 treatment equipment 0 0 Repair or alteration of drainage or vent piping 0 0 Medical gas piping system serving (1 -5) 0 inlets /outlets for a specific gas 0 0 Medical gas piping (6 +) inlets /outlets 0 0 Gas Piping 0 Gas piping outlets (0 -5) 2 0 Gas piping outlets (6 +) 0 PG09 -126 Printed: 11 -02 -2009 Permit Center Authorized Signature: I hereby certify that I have read and e governing this work will be complied The granting of thi a 't does not pres • e to give authority to violate or cancel the provisions of any other state or local laws regulating construction or a pe ance of work. I am authorized to sign and obtain this plumbing /gas piping permit. Date: NOV 2 Z. Signature: Print Name: doc: UPC -7/07 City o?Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us ami 'th, K i 1-40vbE M Permit Number: PGO9 -126 Issue Date: 11/02/2009 Permit Expires On: 05/01/2010 Date: I(_l(A ed th permit and know the same to be true and correct. All provisions of law and ordinances whether specified herein or not. This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. PG09 -126 Printed: 11 -02 -2009 Parcel No.: 2623049098 Address: Suite No: Tenant: • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us 1120 ANDOVER PK E TUKW PACIFIC POWER TECH, LLC 1: ** *PLUMBING AND GAS PIPING * ** PERMIT CONDITIONS • Permit Number: Status: Applied Date: Issue Date: 2: No changes shall be made to applicable plans and specifications unless prior approval is obtained from the Tukwila Building Division. 3: All permits, inspection records and applicable plans shall be maintained at the job and available to the plumbing inspector. 4: All plumbing and gas piping systems shall be installed in compliance with the Uniform Plumbing Code and the Fuel Gas Code. 5: No portion of any plumbing system or gas piping shall be concealed until inspected and approved. PG09 -126 ISSUED 10/27/2009 11/02/2009 6: All plumbing and gas piping systems shall be tested and approved as required by the Plumbing Code and Fuel Gas Code. Tests shall be conducted in the presence of the Plumbing Inspector. It shall be the duty of the holder of the permit to make sure that the work will stand the test prescribed before giving notification that the work is ready for inspection. 7: Plastic and copper piping running through framing members to within one (1) inch of the exposed framing shall be protected by steel nail plates not less than 18 guage. 8: Piping through concrete or masonry walls shall not be subject to any load from building construction. No plumbing piping shall be directly embedded in concrete or masonry. 9: All pipes penetrating floor /ceiling assemblies and fire - resistance rated walls or partitions shall be protected in accordance with the requirements of the building code. 10: Piping in the ground shall be laid on a firm bed for its entire length. Trenches shall be backfilled in thin layers to twelve inches above the top of the piping with clean earth, which shall not contain stones, boulders, cinderfill, frozen earth, or construction debris. 11: The issuance of a permit or approval of plans and specifications shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the Plumbing Code or Fuel Gas Code or any other ordinance of the jurisdiction. doc: Cond -10/06 * * continued on next page ** PG09 -126 Printed: 11 -02 -2009 Signature: Print Name: doc: Cond -10/06 N fiNna • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www:ci.tukwila.wa.us I hereby certify that I have read these conditions and will comply with them as outlined. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provision of any other work or local laws regulating construction or the uerformance of work. Date: NOV Z 200 PG09 -126 Printed: 11 -02 -2009 SITE LOCATION Site Address: Property Owners Name: Mailing Address: 7Z Name: ihl 4-\O\i Mailing Address: PO UO)\ 2�-0Z9- E -Mail Address: K NAC-tE rIF1•1NW. CbM Company Name: K MEeHANIc_S - LPL Mailing Address: PO YoC Z Contact Person: E -Mail Address: Contractor Registration Number: MCCti ° 11 Z1"1P Company Name: Mailing Address: CITY OF TUKWILA Community Development Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 httn://www.ci.tukwila.wa.us PLUMBING / GAS PIPING PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. * *Please Print ** 117-0 AN OK C=AST l..kklA l0�-b A1�5117 i 21AST b FN BOVt KEhI Cam'. MARtyC,tr s1T K\U . can Contact Person: _ E -Mail Address: H :ApplicationsWor ns- Applications On lane \2009 Applications \I -2009 - Plumbing -Gas P iping Permit Application.doc Revised: 1.2009 bh Plumbing /Gas Permit No. 1 i' ©"j -- Project No. (For office use only) King Co Assessor's Tax No.: a(02-.304 - C \093 -0 3 Suite Number: Floor: Tenant Name: Piaci FIG PGVIE . �EcH I LLC- New Tenant: ❑ Yes ® .. No .,Q . 6 .41,14 City State CONTACT PERSON - Who do we contact when your permit is ready to be issued Day Telephone: Z0(c) 903 \ l0( City State Zip Fax Number: Zb(„, 903 1 \lb PLUMBING/ GAS PIPING CONTRACTOR INFORMATION.::: City State Zip Day Telephone: Z.C& ° 105 1100 Fax Number: Z06 X03 I 1 1 to Expiration Date: 1 11\ 2.01 I ARCHITECT. OF RECORD- All plans must be wet stamped by Architect of Record State Cit Day Telephone: Fax Number: ENGINEER OF -All plans must be wet stamped by Engineer of Record Company Name: NONE Mailing Address: City Contact Person: - Day Telephone: E -Mail Address: _ Fax Number: State Zip Zip Zip Page I of 2 Fixture Type: Qty Fixture Type: Qty Fixture Type: Qty Fixture Type: Qty Bathtub or combination bath/shower Bidet Clothes washer, domestic Dental unit, cuspidor Dishwasher, domestic, with independent drain Drinking fountain or water cooler (per head) Food -waste grinder, commercial Floor Drain Shower, single head trap Lavatory Wash fountain Receptor, indirect waste Sinks Urinals Water Closet Building sewer and each trailer park sewer Rain water system - per drain (inside building) Water heater and /or vent Industrial waste treatment interceptor, including trap and vent, except for kitchen type grease interceptors Each grease trap (connected to not more than 4 fixtures - <750 gallon capacity) Grease interceptor for commercial kitchen ( >750 gallon capacity) Repair or alteration of water piping and/or water treatment equipment Repair or alteration of drainage or vent piping Medical gas piping system serving 1 -5 inlets /outlets for a specific gas Each additional medical gas inlets /outlets greater than 5 Backflow protective device other than atmospheric -type vacuum breakers 2 inch (51 mm) diameter or smaller Backflow protective device other than atmospheric -type vacuum breakers over 2 inch (51 mm) diameter Each lawn sprinkler system on any one meter including backflow protection devices Atmospheric -type vacuum breakers not included in lawn sprinkler backflow protections (1 -5) Atmospheric -type vacuum breakers not included in lawn sprinkler backflow protections over 5 Gas piping outlets 2. Date Application Accepted: to - I O ! Date Application Expires: 61-1 1 I 1 ° Staff Initials: I • Building Use (per Int'l Building Code): Occupancy (per Int'l Building Code): Utility Purveyor: Water: COY` Cf — 71.) • Valuation of Project (contractor's bid price): $ 14O t) U)1 t- Scope of Work (please provide detailed information): FU .)--1t 2" CAS PT' \N b R>;000 o,225 , sup 'c r s hazDv/.etzc, SU T 44-07) UNIT E7z ,• . 2. Sewer: crr?' C. iO J'l A Indicate type of plumbing fixtures and /or gas piping outlets being installed and the quantity below: PERMIT APPLICATION NOTES Value of Construction - In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review - Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may grant one extension of time for an additional period not to exceed 180 days. The extension shall be requested in writing and justifiable cause demonstrated. Section 103.4.3 International Plumbing Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. Mailing Address: BUILDING 0 mil' OAt1AJTHORIZED AGENT: Signature: Print Name: K 1-1E" 1.11 PO Pt( 2_402A- Date: OGT- f, 2C)O°) Day Telephone: 2.010 `10 1O0 HAApplications \Forms - Applications On Line \2009 Applications \I -2009 - Plumbing -Gas Piping Permit Application.doc Revised 1 -2009 bh City W4\ 'in 121 State Zip Page 2 of 2 • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site http: / /www.ci.tukwila.wa.us RECEIPT Parcel No.: 2623049098 Permit Number: PG09 -126 Address: 1120 ANDOVER PK E TUKW Status: APPROVED Suite No: Applied Date: 10/27/2009 Applicant: PACIFIC POWER TECH, LLC Issue Date: Receipt No.: R09 -01721 Initials: JEM Payment Date: 11/02/2009 04:12 PM User ID: 1165 Balance: $0.00 Payee: K MECHANICAL LLC TRANSACTION LIST: Type Method Descriptio Amount Payment Check 2046 92.00 Authorization No. ACCOUNT ITEM LIST: Description GAS - NONRES Account Code Current Pmts 000.322.103.00.00 92.00 Total: $92.00 Payment Amount: $92.00 PAYMENT RECEIVED doc: Receiot -06 Printed: 11 -02 -2009 Copy Reprinted on 10 -27 -2009 at 15:35:31 10/27/2009 RECEIPT NO: R09 -01687 Initials: JEM User ID: 1165 Total Payment: 78.82 Payee: K MECHANICAL LLC SET ID: S000001316 SET NAME Temporary Set SET TRANSACTIONS: Set Member M09 -138 PG09 -126 TOTAL: ACCOUNT ITEM LIST: Description PLAN CHECK - NONRES Ci/ of Tukwila. Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206-431-3665 Web site: http: //www. ci. tukwila. wa. us Amount 55.82 23.00 23.00 SET RECEIPT 000.345.830 TOTAL: Payment Date: 10/27/2009 TRANSACTION LIST: Type Method Description Amount Payment Check 2036 78.82 TOTAL: 78.82 Account Code Current Pmts 78.82 78.82 PAYMENT RECEIVED Pr ct: .-- /P�h. )f �C 7 /F /Cv 4w�i7 o Type r f Inspectio : f- / Al 4 / 6 A S Address: / /.Z4 ANdw /2 P f Date Called: Special Instructions: Date Wanted: /.2 -,� /- E . p.m. Requester: Phone No: O 3 INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3 ❑ Approved per applicable codes. Corrections required prior to approval. COMMENTS: V)),rfi,94:im (2 U5 13 (0 4.548 As fs.3 60 0 REINSPECTI01I FEE REQUIRED. Pri to inspection, fee rfiust be at 6300 Southcenter Blvd., Suite 100 all to schedule reinspection. Re ipt No.: Date: /- Date: P ect: , � Vi r (PC k TypeRf Inspection: R(1 .(at-1 :_‘, .1 -1. Address: l 120 A>J t )6JQ8 .p lL Date Called: Special Instructions: . Date Wanted: x.2- 14) a.m. Requester: Phone No: Zvi:— ( 3 l e — e `-{c -c INSPECTION NO. INSPECTION RECORD Retain a copy with permit PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)4 -3670 44 Approved per applicable codes. El Corrections required prior to approval. COMMENTS: 46)0 Inspector: IDatx REINSPECTION F REQUIRED rior to inspection, fee must be at 6300 Southcenter lvd., Suite 100. Call to schedule reinspection. R ---Ipt Date: A C E A 325 -31-44 B 325-3148-44 C 325- 5AL-66 D 325- SAL600 -66 D 325- 5AL600 -88 E 3 -1010 AEVIEWE R CODE COMPLIANCE APPRf VED OCT 2 City of Tukwila BUILDING DIVISION 1/2" x 1/2" 34 "x3/4" 3/4" 1-1/4" 1 -1/4" FILE COPY GAS PRESSURE REGULATORS • Use with natural, mixed, manufactured, LP or LP gas /air mixtures in residential, commercial and industrial applications • Housings are rugged aluminum die castings, and all internal parts are carefully selected and corrosion - resistant • Adjustable within spring range • Pound to inches regulators where adequate inlet pressures are available • Feature high leverage valve linkage to deliver positive deadend lock -up and precise regulating control from full flow down to pilot flows • Self- aligning valve made of Nitrile rubber • Includes automatic vent limiting device with all regulators except L39 - 085 and 1.86 -521 • L39 - 085 and L86 - 521 must be vented if being used indoors • L39 L39 L39 - 084 and L86 - 521 are equipped with over - pressure protection devices (OPD) complying with new ANSI codes for 5 lb. gas pressure • L39 -011 protects breather hole from rain, snow, dust and other foreign matter; not a vent limiting device Specifications: • Maximum inlet pressure: 1.37 - 535 and L37 - 730 CSA rated for 2 or 5 PSI • Maxitrol tested for 10 PSI • Emergency exposure limits: 65 PSI inlet side only • Ambient temperature: -40 °F to +205 °F • Standard spring range: 7" to 11" W.C. Note: All Maxitrol appliance regulators should be installed and operated in accordance with Maxitrol's 'Safety Warning° bulletin (included with product). The latest ANSI Standard for Line Pressure Regulators (221.80) requires that an over - pressure protection device (OPD) be used on any regulator designed for use with 5 lb. gas. Check with your local code officials to see if this applies in your area. 2 Lbs. 5 Lbs. 2 Lbs. 5 Lbs. 5 Lbs. 2 Lbs. 5 Lbs. Veit 145 338 690 Tapped 1/8" NPT 12A09 Upright Tapped 1/8" NPT 12A09 Upright Tapped 3/8" NPT 12A39 Upright Tapped 3/8" NPT 12A39 Upright Tapped 3/8" NPT 12A39 Upright Tapped 1/2" NPT — Mult-Poise Tapped 1/2" NPT — Multi -Poise LARGE LOCAL INVENTORIES 250 583 1191 No Yes No Yes Yes No Yes Order # 1.37 -535 139.982 137-730 L39-053 139.084 139 -085 1.88 -521 139-011 LIST PRICE mRXrFROL A G Order # 137 -535 137-730 L39 -085 43A11 92.71 118.40 317.70 31270 230.79 946.94 1 RECEIVED 13.n CITY OF TUKWLA OCT 2 7 2009 ,HERMIT CENTER 1 1 12J0 KEN HOVDE PO BOX 24024 SEATTLE WA 98124 RE: Permit No. PG09 -126 1120 ANDOVER PK E TUKW Dear Permit Holder: -or- Sincerely, Bill Rambo Permit Technician File: Permit File No. PG09 -126 Department of Community Development Based on the above, you are hereby advised to: Thank you for your cooperation in this matter: Jim Haggerton, Mayor Jack Pace, Director In reviewing our current records, the above noted permit has not received a final inspection by the City of Tukwila Building Division. Per the International Building Code, International Mechanical Code, Uniform Plumbing Code and /or the National Electric Code, every permit issued by the Building Division under the provisions of these codes shall expire by limitation and become null and void if the building or work authorized by such permit has not begun within 180 days from the issuance date of such permit, or if the building or work authorized by such permit is suspended or abandoned at any time after the work has begun for a period of 180 days. Your permit will expire on 06/19/2010. 1) Call the City of Tukwila Inspection Request Line at 206 - 431 -2451 to schedule for the next or final inspection. Each inspection creates a new 180 day period. 2) Submit a written request for permit extension to the Permit Center at least seven (7) days before it is due to expire. Address your extension request to the Building Official and state your reason(s) for the need to extend your permit. The Building Code does allow the Building Official to approve one extension of up to 180 days. If it is determined that your extension request is granted, you will be notified by mail. In the event you do not call for an inspection and /or receive an extension prior to 06/19/2010, your permit will become null and void and any further work on the project will require a new permit and associated fees. 6300 Southcenter Boulevard, Suite #100 0 Tukwila, Washington 98188 o Phone: 206 - 431 -3670 0 Fax: 206 - 431 -3665 ACTIVITY NUMBER: PG09 - 126 DATE: 10 -27 -09 PROJECT NAME: PACIFIC POWER TECH, LLC SITE ADDRESS: 1120 ANDOVER PK W X Original Plan Submittal Response to Correction Letter # Response to Incomplete Letter # Revision # After Permit Issued DEPARTMENTS: t iding heri • Public Works Complete le Incomplete ❑ Comments: TUES/THURS ROUTING: Please Route n Structural Review Required REVIEWER'S INITIALS: APPROVALS OR CORRECTIONS: Documentshouting slip.doc 2 -28 -02 1 PERMIT COORD COPY. PLAN REVIEW/ROUTING SLIP Fire Prevention ❑ Structural Planning Division Permit Coordinator DETERMINATION OF COMPLETENESS: (Tues., Thurs.) DUE DATE: 10-29-09 Not Applicable Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: No further Review Required DATE: DATE: Approved Approved with Conditions le Not Approved (attach comments) ❑ Notation: REVIEWER'S INITIALS: DUE DATE: 11-26-09 Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: Bond Bond Company Name Bond Account Number Effective Date Expiration Date Cancel Date Impaired Date Bond Amount Received Date 1 HARTFORD FIRE INS CO 52BSBFL8065 06/29/2009 Until Cancelled $12,000.00 07/17/2009 Insurance Company Name Policy Number Effective Date Expiration Date Cancel Date Impaired Date Amount Received Date 1 NAVIGATORS INS CO 4610090412 06/29/2009 06/29/2010 $1,000,000.00 07/17/2009 Name Role Effective Date Expiration Date HOVDE, KENNETH A PARTNER /MEMBER 07/17/2009 Untitled Page • 0 General /Specialty Contractor A business registered as a construction contractor with Lai to perform construction work within the scope of its specialty. A General or Specialty construction Contractor must maintain a surety bond or assignment of account and carry general liability insurance. Business and Licensing Information Name Phone Address Suite /Apt. City State Zip County Business Type Parent Company K MECHANICAL LLC 2069031100 PO BOX 24024 SEATTLE WA 98124 KING Limited Liability Company UBI No. Status License No. License Type Effective Date Expiration Date Suspend Date Specialty 1 Specialty 2 602923387 ACTIVE KMECHML912MP CONSTRUCTION CONTRACTOR 7/17/2009 7/17/2011 GENERAL UNUSED Business Owner Information Bond Information Insurance Information https://fortress.wa.gov/lni/bbip/Detail.aspx Page 1 of 1 11/02/2009 Parcel #: 262304- 9098 -03 Legal Description: SE 26 23 4 Begining on the south line of the SE 1/4 of the SE 1/4 166.46 feet west of the SE corner thence N 01 -47 -29 E 213.76 feet to the point of beginning, thence N 88 -12 -31 W 253 feet to the east line of Andover Park East, thence N 01 -47 -29 E 207 feet, thence S 88 -12 -31 E 253 feet, thence S 01 -47 -29 W 207 feet to the point of beginning less recorded railroad right of way. Scope of Work: Coordinate the installation of a new natural gas survice to the subject building with Puget Sound Energy and Potelco Construction. Furnish and install interior fuel line piping, valves, regulators and unit heater appliances for the purpose of heating the assembly shop and warehouse areas. Remove existing electrical unit heaters and safe off existing circuits. co W cO 0 I- > -0 0 4" ach adule 40 w conduit. slued w/ 30" !mum{ s:Dyer— 4' x 6' x 3' deep work pit for Potelco Office Site Plan PL = 253.00' PL = 253.00' 4' x 10' x 3' deep work pit for Potelco New Meter Location Pacific Power Tech 1120 Andover Park East Tukwila, WA 98118 Warehouse Assembly SCALE: 1/16" = 1' -0" FILE COPY Permit No. �Goq 1 alp Plan review approval Is subjeatoerrors and omissions. Approval of construction documents does not authorize the violation of : ► adopted code or ordnance. Receipt of approved "- ; • • k, : , conditions is acknowledged: " ►.._ By Date: NON! 2 ?Cr5 city Of Tlukwila BUILDING DIVISION REVISIONS No changes shall be made to the sco pe of work without prior approval of Tukwila Building Division. NOTE: Revisions will require a new plan submittal and may include additional plan review fees. REVIEWED FOR CODE COMPLIANCE APPROVED OCT 2 9 2009 RECEIVED CITY OF TUKWILA OCT 2 7 'film PERMIT CENTER 47 City of Tukwila BUILDING CIVISIf1N PG)01--12.(0 I V15[ON5: Sheet: K Mechanical, LLC PO Box 24024 Seattle, WA 98124 3 Ken Hovde T= (206) 903 -1100 F= (206) 903 -1116 Contractor License: KMECHML 912MP T -1 of 3 Pate: October 14, 2009 ® 32' 32' 32' 3' -6" f X North Shop Warehouse / Reflected Ceiling / Floor Plan New Meter Location Vertical 2" schedule 40 to roof structure, secure tea strut and strap. Horizontal 2" schedule 40 black pipe support at each roof structure perlln. side lam bracket, rod and pear hanger assembly, see T-3 for material detail. NEY 4x14 roof structure pedin, typical. 3/4 tee and service to valve/ regulator, typical of two locations. 2" Cap - future offset and wall penetration for future unit heat. South Warehouse / Shop SCALE: 1/8" = 1 -0" Exterior Dock PG REVIEWED FOR CODE COMPLIANCE APPROVED OCT 2 9 2009 City of Tukwila BUILDING DIVI InM RECEIVED CITY OF TUKWILA OCT 2 7 2009 PERMIT CENTER f V1510N5; K Mechanical LLc P.O. Box 24024 Seattle, WA 98124 Ken Hovde T= (206) 903 -1100 F= (206) 903 -1116 Contractor License: KMECHML 912MP Sheet, T -2 of 3 bate, October 14, 2009 Gas service line underground - see site plan T -1 48' 48' 24' Office Q ©© Piping & Equipment Riser Diagram Roof Plan North Warehouse / Shop 0 New Meter Location 10" Vent with roof repair, typical 2 places 0 South Warehouse / Shop No Scale Unit Heater Pressure Reg. Gas Valve Gas Meter Fuel Line Fuel Line Cap End SCALE: 1/16" = 1' -0" Modine Maxitrol Parker /equal PSE 2" nominal 3/4" Nominal 2" Nominal PD350SA0111 325 -AL -66 60Ib - 3/4 w/ test port 1000 - 2 psi Schedule 40, black Schedule 40, black Future off -set & continuance 2" sched 40 gas line exisitng roof structure Horizontal pipe hanging assembly @ 8' -0" o.c. min Vertical pipe support detail Modine Unit Heater unit heater control valve Vertical pipe support detail 2" rigid strut strap w/ two 3/8 x3.25 wedge anchor, 2 assemblies on vertical 2" schedule 40 fuel line exterior building wall, north elevation to meter set 2' -6" 3/8 x 3 lag bolt with lock washer and strut "L" bracket. 3/8 threaded rod with flat washer & double nut lock down each end 2" rigid pear hanger 3/4 flex line Scale: 1/2" = 1' -0" T3 B Scale: 1/2" = 1' -0" T3 10" round vent single wall, 26ga., screw 4ea & seal PG V-- Pio 10" vent globe 10" vent, 26 gage Thimble & flat roof Jack w/ storm collar, torch down roof repair fuel pressure regulator - 2 psi Scale: 1/2" = 1' -0" 3/4 x 4 sediment catch 3 0-- 2" fuel line Existing roof structure 3/4 schedule 40 pipe to unit heater, typical of two heaters 3/4 gas valve rated for 60Ib w/ test port REVIEWED FOR CODE COMPLIANCE APPROVED OCT 2 9 2009 City of Tukwila BUILDING DiVIslllN RECEIVED CITY OF TUKWILA OCT 2 2009 PERMIT CENTER MVISION5: Sheet: of 3 Pate: October 14, 2009 K Mechanical LLc P.O. Box 24024 Seattle, WA 98124 Ken Hovde T= (206) 903 -1100 F= (206) 903 -1116 Contractor License: KMECHML 912MP T -3