Loading...
HomeMy WebLinkAboutPermit PG09-129 - PRIME ALLIANCERIME ALLIANCE 12720 GATEWAY DR Parcel No.: 2716000070 Address: Suite No: 12720 GATEWAY DR TUKW City Of Tukwila Tenant: Name: PRIME ALLIANCE Address: 12720 GATEWAY DR , TUKWILA WA Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www:ci.tukwila.wa.us Owner: Name: RREEF AMERICA REIT II CORP/ Address: PO BOX 4900 #207 , SCOTTSDALE AZ Contact Person: Name: JOE PAPERNIK Address: 222 ANDERSON RD UNIT H , MT VERNON WA PLUMBING /GAS PIPING PERMIT Contractor: Name: CITY PLUMBING INC Address: 222 ANDERSON RD UNIT A , MOUNT VERNON WA Contractor License No: CITYPI *955KJ DESCRIPTION OF WORK: MOVE EXISTING SINK 7 FEET Value of Plumbing /Gas Piping: Fees Collected: Plumbing Bathtub or combination bath/shower Bidet Clothes washer, domestic Dental unit, cuspidor Dishwasher, domestic, with independent drain Drinking fountain or water cooler (per head) Food -waste grinder, commercial Floor drain Shower, single head trap Lavatory Wash fountain Receptor, indirect waste Sinks Urinals Water Closet doc: UPC -7/07 $1,450.00 $58.00 FIXTURE TYPE AND QUANTITY * *continued on next page ** Permit Number: Issue Date: Permit Expires On: Phone: Phone: 360 - 661 -5568 Phone: 360 416 -6653 Expiration Date: 08/01/2010 PG09 -129 11/03/2009 05/02/2010 Uniform Plumbing Code Edition: 2006 International Fuel Gas Code Edition: 2006 Plumbing (cont.) 0 Building sewer and each trailer park sewer 0 0 Ram water system - per drain (inside bldg) 0 0 Water heater and /or vent 0 0 Industrial waste treatment interceptor, including 0 its trap and vent, except for kitchen type 0 grease interceptors 0 0 Repair or alteration of water piping and/or water 0 treatment equipment 0 0 Repair or alteration of drainage or vent piping 0 0 Medical gas piping system serving (1 -5) 0 inlets /outlets for a specific gas 1 0 Medical gas piping (6 +) inlets /outlets 1 0 Gas Piping 0 Gas piping outlets (0 -5) 0 0 Gas piping outlets (6 +) 0 PG09 -129 Printed: 11 -03 -2009 Permit Center Authorized Signature: Signature: __ Print Name: doc: UPC -7/07 City ot Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us Permit Number: PG09 -129 Issue Date: 11/03/2009 Permit Expires On: 05/02/2010 Date: Date: / I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the perf • - an of k. I am authorized to sign and obtain this plumbing /gas piping permit. This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. PG09 -129 Printed: 11 -03 -2009 Parcel No.: 2716000070 Address: Suite No: Tenant: PRIME ALLIANCE 1: ** *PLUMBING AND GAS PIPING * ** • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us 12720 GATEWAY DR TUKW PERMIT CONDITIONS Permit Number: Status: Applied Date: Issue Date: PG09 -129 ISSUED 11/03/2009 11/03/2009 2: No changes shall be made to applicable plans and specifications unless prior approval is obtained from the Tukwila Building Division. 3: All permits, inspection records and applicable plans shall be maintained at the job and available to the plumbing inspector. 4: All plumbing and gas piping systems shall be installed in compliance with the Uniform Plumbing Code and the Fuel Gas Code. 5: No portion of any plumbing system or gas piping shall be concealed until inspected and approved. 6: All plumbing and gas piping systems shall be tested and approved as required by the Plumbing Code and Fuel Gas Code. Tests shall be conducted in the presence of the Plumbing Inspector. It shall be the duty of the holder of the permit to make sure that the work will stand the test prescribed before giving notification that the work is ready for inspection. 7: No water, soil, or waste pipe shall be installed or permitted outside of a building or in an exterior wall unless, adequate provision is made to protect such pipe from freezing. All hot and cold water pipes installed outside the conditioned space shall be insulated to minimum R -3. 8: Plastic and copper piping running through framing members to within one (1) inch of the exposed framing shall be protected by steel nail plates not less than 18 guage. 9: Piping through concrete or masonry walls shall not be subject to any load from building construction. No plumbing piping shall be directly embedded in concrete or masonry. 10: All pipes penetrating floor /ceiling assemblies and fire - resistance rated walls or partitions shall be protected in accordance with the requirements of the building code. 11: Piping in the ground shall be laid on a firm bed for its entire length. Trenches shall be backfilled in thin layers to twelve inches above the top of the piping with clean earth, which shall not contain stones, boulders, cinderfill, frozen earth, or construction debris. 12: The issuance of a permit or approval of plans and specifications shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the Plumbing Code or Fuel Gas Code or any other ordinance of the jurisdiction. doc: Cond -10/06 * *continued on next page ** PG09 -129 Printed: 11 -03 -2009 Signature: Print Name: • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us I hereby certify that I have read these conditions and will comply with them as outlined. All provisions this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provision of any construction or the performance of work. doc: Cond -10/06 PG09 -129 Date: H g — v/ of law and ordinances governing other work or local laws regulating Printed: 11 -03 -2009 SITE LOCATION - Site Address: Tenant Name: I'r'i 1/ a a LP Property Owners Name: leg CE: f v R e.L� co , pO 72 Cc ?�'7 �crll Mailing Address: CONTACT PERSON - Who do we contact when your permit is ready to be issued ' PQ.. ?Wlrlc Mailing Address: Name: E -Mail Address: E -Mail Address: Company Name: Mailing Address: CITY OF TUKWILA Community Development Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www.ci.tukwila.wa.us PLUMBING / GAS PIPING PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. • * *Please Print ** ) 2720 Air Contact Person: ? p e -v 1.1.1 r 1( (phi r . 509 ee. 1 j - Contractor Registration Number: r A T ) 4 Contact Person: E -Mail Address: Contact Person: E -Mail Address: H: \Applications\Porms=Applications On Line \2009 Applications \1-2009 - Plumbing -Gas Piping Permit Application.doc Revised: 1 -2009 bh Plumbing /Gas Permit No. " PC q— p_ef Project No. (For office use only) King Co Assessor's Tax No.: 61 00' 007 0 Suite Number: /OS Floor: / New Tenant: � Yes ❑..No R City Fax Number: 1j6! State City State Zip - cll(-- Gla.s"l PLUMBING GAS : PIPING CONTRACTOR ;INFORMATIO Company Name: Cpl ?!U.L14,6 .1-c- L , r / Mailing Address: ?i2_ (A/4z, E rt,l,.I f A- Yf r' �N V 4 Lut L `�� Q a7 2 , City State Day Telephone: — CYO Fax Number: — b G 61 Expiration Date: 0 Day Telephone: C O (o ea / 1A Vert _AA 9tZ7 State State Zip Zip ARCHITECT RECORD - All plans must be wet stamped by Architect of Record Company Name: Mailing Address: Zip City Day Telephone: Fax Number: ENGINEER OF,RECORD - All plans must be wet stamped by Engineer of Record Zip City Day Telephone: Fax Number: Page 1 of 2 Fixture Type: Qty Fixture Type: Qty Fixture Type: Qty Fixture Type: Qty Bathtub or combination bath/shower Bidet Clothes washer, domestic Dental unit, cuspidor Dishwasher, domestic, with independent drain Drinking fountain or water cooler (per head) Food -waste grinder, commercial Floor Drain Shower, single head trap Lavatory Wash fountain Receptor, indirect waste Sinks it Urinals Water Closet Building sewer and each trailer park sewer Rain water system – per drain (inside building) Water heater and /or vent Industrial waste treatment interceptor, including trap and vent, except for kitchen type grease interceptors Each grease trap (connected to not more than 4 fixtures - <750 gallon capacity) Grease interceptor for commercial kitchen ( >750 gallon capacity) Repair or alteration of water piping and /or water treatment equipment 1 1 Repair or alteration of drainage or vent piping ' t 1 Medical gas piping system serving 1 -5 inlets /outlets for a specific gas Each additional medical gas inlets /outlets greater than 5 Backflow protective device other than atmospheric -type vacuum breakers 2 inch (51 mm) diameter or smaller Backflow protective device other than atmospheric -type vacuum breakers over 2 inch (51 mm) diameter Each lawn sprinkler system on any one meter including backflow protection devices Atmospheric -type vacuum breakers not included in lawn sprinkler backflow protections (1 -5) Atmospheric -type vacuum breakers not included in lawn sprinkler backflow protections over 5 Gas piping outlets • , ' PERMIT APPLICATION NOTES ° '° , Valuation of Project (contractor's bid price): $ /Y Scope of Work (please provide detailed information): - J-/C-- F y . / Building Use (per Int'I Building Code): Occupancy (per Int'I Building Code): Utility Purveyor: Water: Indicate type of plumbing fixtures and/or gas piping outlets being installed and the quantity below: Value of Construction – In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review – Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may grant one extension of time for an additional period not to exceed 180 days. The extension shall be requested in writing and justifiable cause demonstrated. Section 103.4.3 International Plumbing Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING 0 Date Application Accepted: AUT D AGENT: Signature: Print Name: �DC� �b ,,'� r s Mailing Address: 22- t �fttr H:Wpplications\Forms- Applications On Line12009 Applications\1 -2009 - Plumbing -Gas Piping Permit Application.doc Revised: 1-2009 bh • City State Sewer: Date: Day Telephone: 3 6 , 1) - CeC, / - S'S' 6 S M.-i ItAv&LA aSZ73 Zip Date Application Expires: Staff Initials: Page 2 of 2 Parcel No.: 2716000070 Address: 12720 GATEWAY DR TUKW Suite No: Applicant: PRIME ALLIANCE Receipt No.: R09 -01728 Initials: User ID: Payee: WER 1655 JOE PAPERNIK TRANSACTION LIST: Type Method Descriptio Amount Payment Credit Crd VISA - Authorization No. 003907 ACCOUNT ITEM LIST: Description PLUMBING - NONRES • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Fax: 206 - 431 -3665 Web site: http://www.ci.tulcwila.wa.us RECEIPT 58.00 Payment Amount: $58.00 Account Code Current Pmts 000.322.103.00.00 58.00 Total: $58.00 Permit Number: PG09 -129 Status: PENDING Applied Date: 11/03/2009 Issue Date: Payment Date: 11/03/2009 11:29 AM Balance: $0.00 PAYMENT ECEIVED doc: Receiot -06 Printed: 11 -03 -2009 Project: Pr te , n. �l� ype o Type Inspection: RA a( pl,,Avt6.4f Date Called: Address: / 27 j 6 �A- Special Instructions: I 4 0 3 1 ? 6- Q Z fAvie- S, Al k Date Wanted: 1 2 - 4 `O '��a rpm p.m. Requester: Phone No: 2..,i) Co — Si 0 —1 7 72 ( 3 INSPECTION NO. INSPECTION RECORD Retain a copy with permit PERMIT NO. CITY OF TUKWILA BUILDING DIVISION ; --4 1 2-- 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 Approved per applicable codes. Corrections required prior to approval. COMMENTS: pp rM:r oky Inspeclr: A4 .,) Date: /1-4- o I El $60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: Date: 1 Pro}gct: , + Type of Inspectign: Address: ( 7 � W�y02. Date Called G r a ,_„ _ ' JdC* �- Special Instructions: �/ / �r A.[ JIG � � t'�-- co Fee. ok _ / // Date Wanted: I ! 's`U /f p.m. Requester: Phone No:, ?.o Si 0 ' 7�2� INSPECTION RECORD Retain NO. PERMIT NO. etain a copy with permit CITY OF TUKWILA BUILDING DIVISION t 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 El f Approved per applicable codes. 0 Corrections required prior to approval. COMMENTS: / Ir(spector: Date: C /, 1l� 7 ❑ $60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be • paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: Date: License Name Type yp Specialty 1 p y Specialty 2 p y Effective Date Expiration Date Status CITYM * *019CE CITY MECHANICAL CONSTRUCTION CONTRACTOR PLUMBING WATER CONDITIONING EQUIPMENT 2/5/1999 2/1/2000 ARCHIVED WITTMP *954L9 WITTMAL PLUMBING CONSTRUCTION CONTRACTOR PLUMBING WELDING 6/29/2005 6/29/2007 EXPIRED CITYPMI985M3 CITY PLUMBING 8 MECHANICAL INC CONSTRUCTION CONTRACTOR BOILER /STEAM FIT /PROC PIPING PLUMBING 8/1/2002 8/1/2006 INACTIVE Name Role Effective Date Expiration Date PAPERNIK, JOSEPH III PRESIDENT 05/11/2005 Bond Amount BERKMAN, RICHARD L VICE PRESIDENT 05/11/2005 LPM4071975 Bond Bond Company Name Bond Account Number Effective Date Expiration Date Cancel Date Impaired Date Bond Amount Received Date 3 COLONIAL AM CAS 8 SURETY OF MARYLAND LPM4071975 08/01/2006 Until Cancelled $6,000.00 07/28/2006 ACCREDITED Untitled Page • General /Specialty Contractor A business registered as a construction contractor with L81 to perform construction work within the scope of its specialty. A General or Specialty construction Contractor must maintain a surety bond or assignment of account and carry general liability insurance. Business and Licensing Information Name Phone Address Suite /Apt. City State Zip County Business Type Parent Company CITY PLUMBING INC UBI No. 3604166653 Status 222 ANDERSON RD UNIT A MOUNT VERNON WA 98273 SKAG IT Corporation License No. License Type Effective Date Expiration Date Suspend Date Specialty 1 Specialty 2 602218839 ACTIVE CITYPI *955KJ CONSTRUCTION CONTRACTOR 5/11/2005 8/1/2010 PLUMBING UNUSED Other Associated Licenses Business Owner Information Bond Information Page 1 of 2 https: // fortress .wa.gov /lni/bbip /Detail.aspx 11/03/2009