Loading...
HomeMy WebLinkAboutPermit PG09-134 - US BANKUS BANK 151 ANDOVER PK E EXPIRED 06 -14 -10 PGO9-134 Parcel No.: 0223100038 Address: Suite No: 151 ANDOVER PK E TUKW CitAf Tukwila Tenant: Name: US BANK Address: 151 ANDOVER PK E , TUKWILA WA Owner: Name: U S BANK CORPORATE PROPS Address: 2800 E LAKE ST , LAKE0012 Contact Person: Name: JOFFRE SECHIER Address: 6802 S 220 ST , KENT WA Contractor: Name: COMFORT MECHANICAL INC Address: 6617 S 193 PL, #P -105 , KENT, WA Contractor License No: COMFOMI015LA Value of Plumbing /Gas Piping: Fees Collected: Plumbing Bathtub or combination bath/shower 0 Bidet 0 Clothes washer, domestic 0 Dental umt, cuspidor 0 Dishwasher, domestic, with independent drain 0 Drinking fountain or water cooler (per head) 0 Food -waste grinder, commercial 0 Floor drain 0 Shower, single head trap 0 Lavatory 0 Wash fountain - Receptor, indirect waste 0 Sinks 0 Urinals 0 Water Closet 0 doc: UPC -7/07 Department of Community Development 6300 Southcenter Boulevard, Suite # 100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Inspection Request Line: 206 - 431 -2451 Web site: http: / /www.ci.tukwila.wa.us DESCRIPTION OF WORK: INSTALL 1 -1/2 INCH GALVANIZED IRON PIPE TO ROOFTOP UNIT $1,250.00 $115.00 • PLUMBING /GAS PIPING PERMIT FIXTURE TYPE AND OUANTITY 0 * *continued on next page ** Permit Number: Issue Date: Permit Expires On: Phone: Phone: 425 251 -9840 Phone: 425 - 251 -9840 Expiration Date: 06/01/2010 PG09 -134 11/25/2009 05/24/2010 Uniform Plumbing Code Edition: 2006 International Fuel Gas Code Edition: 2006 Plumbing (cont.) Building sewer and each trailer park sewer 0 Rain water system - per drain (inside bldg) 0 Water heater and /or vent 0 Industrial waste treatment interceptor, including its trap and vent, except for kitchen type grease interceptors 0 Repair or alteration of water piping and/or water treatment equipment 0 Repair or alteration of drainage or vent piping 0 Medical gas piping system serving (1 -5) inlets /outlets for a specific gas 0 Medical gas piping (6 +) inlets /outlets 0 Gas Piping Gas piping outlets (0 -5) 1 Gas piping outlets (6 +) 0 PG09 -134 Printed: 11 -25 -2009 Permit Center Authorized Signature: governing this work will be complied w The granting o construction\r Signature: Print Name: doc: UPC -7/07 this t he City o Department of Community Development 6300 Southcenter Boulevard, Suite # 100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Inspection Request Line: 206 - 431 -2451 Web site: http: / /www.ci.tukwila.wa.us S.,6v Permit Number: PG09 -134 Issue Date: 11/25/2009 Permit Expires On: 05/24/2010 if Date: 1(I7 I hereby certify that I have read and ex d this • ermit and know the same to be true and correct. All provisions of law and ordinances ether specified herein or not. mit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating for ce of work. I am authorized to sign and obtain this plumbing /gas piping permit. Date: % This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. PG09 -134 Printed: 11 -25 -2009 Parcel No.: 0223100038 Address: Suite No: Tenant: US BANK • 1 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us 151 ANDOVER PK E TUKW 1: ** *PLUMBING AND GAS PIPING * ** PERMIT CONDITIONS Permit Number: Status: Applied Date: Issue Date: PG09 -134 ISSUED 11/12/2009 11/25/2009 2: No changes shall be made to applicable plans and specifications unless prior approval is obtained from the Tukwila Building Division. 3: All permits, inspection records and applicable plans shall be maintained at the job and available to the plumbing inspector. 4: All plumbing and gas piping systems shall be installed in compliance with the Uniform Plumbing Code and the Fuel Gas Code. 5: No portion of any plumbing system or gas piping shall be concealed until inspected and approved. 6: All plumbing and gas piping systems shall be tested and approved as required by the Plumbing Code and Fuel Gas Code. Tests shall be conducted in the presence of the Plumbing Inspector. It shall be the duty of the holder of the permit to make sure that the work will stand the test prescribed before giving notification that the work is ready for inspection. 7: Piping through concrete or masonry walls shall not be subject to any load from building construction. No plumbing piping shall be directly embedded in concrete or masonry. 8: All pipes penetrating floor /ceiling assemblies and fire - resistance rated walls or partitions shall be protected in accordance with the requirements of the building code. 9: The issuance of a permit or approval of plans and specifications shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the Plumbing Code or Fuel Gas Code or any other ordinance of the jurisdiction. doc: Cond -10/06 * *continued on next page ** PG09 -134 Printed: 11 -25 -2009 • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us I hereby certify that I have read these conditions and will comply with them as outlined. All provisions of law and this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provision of any other work construction he performance of work. Signature: Print Name: ac4 doc: Cond - PG09 -134 Date : L1C ordinances governing or local laws regulating Printed: 11 -25 -2009 CITY OF TUKWILA Community Development Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http: //www. ci. tukwila. wa. us SITE LOCATION Site Address: IS , 1 Tenant Name: US Property Owners Name: � Mailing Address: ^-. CONTACT PERSON - Who do we contact when your permit is ready to be issued Name: a �� .7c1$V" Mailing Address: E -Mail Address: Company Name: Mailing Address: Contact Person: E -Mail Address: , 1 PLUMBING / GAS PIPING CONTRACTOR INFORMATION PLUMBING / GAS PIPING PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. * *Please Print ** C yh> hng.0 . • (b1N■ Contractor Registration Number: t'vWC L6 ARCHITECT OF RECORD - All plans must be wet stamped by Architect of Record Company Name: Mailing Address: City Contact Person: _ Day Telephone: E -Mail Address: Fax Number: ENGINEER OF RECORD - All plans must be wet stamped by Engineer of Record Company Name: Mailing Address: City Contact Person: Day Telephone: E -Mail Address: Fax Number: H:\Applications\Ponns- Applications On Line\2009 Applications \1 -2009 - Plumbing -Gas Piping Permit Application.doc Revised: 1 -2009 bh Plumbing/Gas Permit No. Project No. King Co Assessor's Tax No.: vD .1 ' 0003 Suite Number: City Day Telephone: ,QW'J City Fax Number: New Tenant: ❑ Yes State Floor: State Zip Zip City State Q Zip Day Telephone: LI — 1 — Fax Number: L OS Expiration Date: 610'0t e t 6 6 State State i Zip Zip 0 Page 1 of 2 Fixture Type: Qty Fixture Type: Qty Fixture Type: Qty Fixture Type: Qty Bathtub or combination bath/shower Bidet Clothes washer, domestic Dental unit, cuspidor Dishwasher, domestic, with independent drain Drinking fountain or water cooler (per head) Food -waste grinder, commercial Floor Drain Shower, single head trap Lavatory Wash fountain Receptor, indirect waste Sinks Urinals Water Closet Building sewer and each trailer park sewer Rain water system — per drain (inside building) Water heater and/or vent Industrial waste treatment interceptor, including trap and vent, except for kitchen type grease interceptors Each grease trap (connected to not more than 4 fixtures - <750 gallon capacity) Grease interceptor for commercial kitchen ( >750 gallon capacity) Repair or alteration of water piping and/or water treatment equipment Repair or alteration of drainage or vent piping Medical gas piping system serving 1 -5 inlets/outlets for a specific gas Each additional medical gas inlets /outlets greater than 5 Backflow protective device other than atmospheric -type vacuum breakers 2 inch (51 mm) diameter or smaller Backflow protective device other than atmospheric -type vacuum breakers over 2 inch (51 nun) diameter Each lawn sprinkler system on any one meter including backflow protection devices Atmospheric -type vacuum breakers not included in lawn sprinkler backflow protections (1 -5) Atmospheric -type vacuum breakers not included in lawn sprinkler backflow protections over 5 Gas pip' o tlets / , \J ( `J l Q 1 1 r Valuation of Project (contractor's bid price): $ 1 O Scope of Work (please provide detailed info ation): -- IsiNS - \ 0 A\ (6 t 6).VAA--1" Pest- Building Use (per Int'l Building Code): Occupancy (per Int'l Building Code): Utility Purveyor: Water: Sewer: Indicate type of plumbing fixtures and/or gas piping outlets being installed and the quantity below: PERMIT APPLICATION NOTES - Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may grant one extension of time for an additional period not to exceed 180 days. The extension shall be requested in writing and justifiable cause demonstrated. Section 103.4.3 International Plumbing Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING O OR A THORIZED AGENT: c rr ✓ 1 \� Mailing Address: (..03 bR dJ, Signature: Print Name: I Date Application Accepted: Ith2,101 Date Application Expires: H:\ApplicationsTorms- Applications On Line\2009 Applications \1 -2009 - Plumbing -Gas Piping Permit Application.doc Revised: 1 -2009 bh City ail 12110 Date: � c`V • if c-�IJU Day Telephone: ' - L s --, 2 s (� , LA- State Zip Staff Initials: 6 age 2 of 2 Parcel No.: 0223100038 Address: 151 ANDOVER PK E TUKW Suite No: Applicant: US BANK Receipt No.: R09 -01894 Initials: User ID: Payee: JEM 1165 ACCOUNT ITEM LIST: Description doc: Receiot -06 GAS - NONRES • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us COMFORT MECDHANICAL, INC. TRANSACTION LIST: Type Method Descriptio Amount Payment Check 13875 92.00 Authorization No. RECEIPT 0 Payment Amount: $92.00 Account Code Current Pmts 000.322.103.00.00 92.00 Total: $92.00 Permit Number: PG09 -134 Status: APPROVED Applied Date: 11/12/2009 Issue Date: Payment Date: 11/25/2009 09:47 AM Balance: $0.00 PAYME.. T RECEIVED Printed: 11 -25 -2009 RECEIPT NO: R09 -01793 Initials: JEM Payee: COMFORT MECHANICAL, INC. SET TRANSACTIONS: Set Member M09 -145 PG09 -134 TOTAL: ACCOUNT ITEM LIST: Description PLAN CHECK - NONRES Ci, of Tukwila, Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http: //www. ci. tukwila. wa. us SET RECEIPT User ID: 1165 Total Payment: 127.22 SET ID: S000001321 SET NAME: Tmp set/Initialized Activities Amount 104.22 23.00 104.22 TRANSACTION LIST: Type Method Description Amount Payment Check 13832 127.22 TOTAL: 127.22 Account Code Current Pmts 000.345.830 TOTAL: Payment Date: 11/12/2009 127.22 127.22 PAYMENT RECEIVED COMMENTS: 7 0 / , l}, 3 -35-(,a Type of Inspection: A?dp h - / ", --kc Gtv i.0kA L - EA f I'S :04- a. is PS: Date Called: k fh1-e (f 4rE J A S - i/k CSC c - r;k--e I -or' r-;./A.11 *- it.,-- �s r e c4,,,,._. N s) A . a.m. 0 Aca („)i.ple kflt-e, JJ,16;r5 A' SEA( A .9 /ke.A rAT. , A 4.4 Phone No: r -y<] f5 : u �t_.- . t A`t ( / ,'r — �1 A 1 A Project: 2,/5 A,% ,%/-C Type of Inspection: A?dp h - / ", ‘A S Address: / 5/ 4 A✓)a 4 Pe E Date Called: Special Instructions: 3 ����, ot p AID f oO G '�� �! Date Wanted: ��— /4 - . mss a.m. Requester: Phone No: INSPECTION NO. INSPECTION RECORD Retain a copy with permit PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 Approved per applicable codes. Corrections required prior to approval. n $60.00 REINSPECTION FEE REOUIRED1Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Inspec or: Date: I z_ /6_ (i f Receipt No.: Date: 1a JOFFRE SECHIER 6802 S 220 ST KENT WA 98032 RE: Permit No. PG09 -134 151 ANDOVER PK E TUKW Dear Permit Holder: In reviewing our current records, the above noted permit has not received a final inspection by the City of Tukwila Building Division. Per the International Building Code, International Mechanical Code, Uniform Plumbing Code and /or the National Electric Code, every permit issued by the Building Division under the provisions of these codes shall expire by limitation and become null and void if the building or work authorized by such permit has not begun within 180 days from the issuance date of such permit, or if the building or work authorized by such permit is suspended or abandoned at any time after the work has begun for a period of 180 days. Your permit will expire on 06/14/2010. Based on the above, you are hereby advised to: 1) Call the City of Tukwila Inspection Request Line at 206 - 431 -2451 to schedule for the next or final inspection. Each inspection creates a new 180 day period. -or- 2) Submit a written request for permit extension to the Permit Center at least seven (7) days before it is due to expire. Address your extension request to the Building Official and state your reason(s) for the need to extend your permit. The Building Code does allow the Building Official to approve one extension of up to 180 days. If it is determined that your extension request is granted, you will be notified by mail. In the event you do not call for an inspection and /or receive an extension prior to 06/14/2010, your permit will become null and void and any further work on the project will require a new permit and associated fees. Thank you for your cooperation in this matter. Sincerely, Bill Rambo Permit Technician File: Permit File No. PG09 -134 Jim Haggerton, Mayor epartment of Community Development Jack Pace, Director 6300 Southcenter Boulevard, Suite #100 o Tukwila, Washington 98188 o Phone: 206 - 431 -3670 0 Fax: 206 - 431 -3665 ACTIVITY NUMBER: PG09 - 134 DATE: 11 -12 -09 PROJECT NAME: US BANK SITE ADDRESS: 151 ANDOVER PK E X Original Plan Submittal Response to Correction Letter # Response to Incomplete Letter # Revision # After Permit Issued DEPARTMENTS: �� rr Bui ng D'visi it Public Works Complete Comments: APPROVALS OR CORRECTIONS: Approved ❑ Approved with Conditions Notation: REVIEWER'S INITIALS: Documents/routing slip.doc 2 -28 -02 • PERMIT cooRDcoPY PLAN REVIEW/ROUTING SLIP Fire Prevention Incomplete n n DATE: DATE: Planning Division ❑ Structural ❑ Permit Coordinator ❑ DETERMINATION OF COMPLETENESS: (Tues., Thurs.) DUE DATE: 11-17-09 Not Applicable Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: TUES /THURS ROUTING: Please Route Structural Review Required ❑ No further Review Required U REVIEWER'S INITIALS: Not Approved (attach comments) U n DUE DATE: 12-15-09 Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: License Name Type Specialty 1 Specialty 2 Effective Date Expiration Date Status FIVESM *01 OJT FIVE STAR MECHANICAL CONSTRUCTION CONTRACTOR GENERAL UNUSE 4/30/19994/30/2010 ACTIVE CO.MFOP'064D2 COMFORT PLUS CONSTRUCTION CONTRACTOR AIR CONDITIONING AIR HEAT,VENTILATION,EVAPORAT 3/22/1994 3/21/2000 ARCHIVED FIVESSE941KU FIVE STAR ENERGY SOLUTIONS CONSTRUCTION CONTRACTOR GENERAL UNUSE 5/24/2006 5/24/2008 EXPIRED Pond Bond Company Name Bond Account Number Effective Date Expiration Date Cancel Date Impaired Date Bond Amount Received Date 2 COLONIAL AM CAS >* SURETY OF MD LPM4041162 06/01/2002 n Cancelled $6,000.00 05/15/2002 1 COLONIAL AM CAS & SURETY OF MD LPM4041162 06/01/1999 06/01/2002 $4,000.00 Name Role Effective Date Expiration Date JACKSON, SHIRLEY A 01/01/1980 JACKSON, HERB J 01/01/1980 Untitled Page General /Specialty Contractor A business registered as a construction contractor with LEtI to perform construction work within the scope of its specialty. A General or Specialty construction Contractor must maintain a surety bond or assignment of account and carry general liability insurance. Business and Licensing Information Name Phone Address Suite /Apt. City State Zip County Business Type Parent Company COMFORT MECHANICAL INC 4252519840 6802 SO. 220TH STREET KENT WA 98032 KING Corporation UBI No. Status License No. License Type Effective Date Expiration Date Suspend Date Specialty 1 Specialty 2 601954041 ACTIVE COMFOMI015LA CONSTRUCTION CONTRACTOR 6/1/1999 6/1/2010 HTG /VENT /AIR CONDITIONING UNUSED Other Associated Licenses Business Owner Information Bnnd Information r Insurance Information • 1 Page 1 of 2 1111 ps: // fortress .wa.gov /lni /bbip /Detail.aspx 11/25/2009 # Brand Model Ton Trial CFM OSA CFM Econo. SP Cap. Cool EER Btuh -In Btuh -Out AFUE Weight 1 Trane YFD241 20 8,000 1600 0 -100% 0.5 265,550 11 400,000 324,000 81 3228# ms '• 1C2001 Kiy 7 0,14 wt{it11.1 1 IC 20 2101Ce `Wia1:1n4m+a,�•�awrnp'liaM' Cowro�icafra m.^4Wor utlk 1ryp n il nutl w 11 h∎Jr4 411 11 unp ea p t mil 1 ' T1ff 1p1 1/A Ilti441atttal:Z iwr,b ... 1inA1u19 , 2,114 bt '6 1 1 :11 r � a k?+1Ff9' i'k f1`.'Fi$1 i /01 444� r � {- 111 �aY• 'r . !FTr 43 19 ...P11gm.. mA aa9x?? 0223100031 0223100003 King County Assessor information for parcel number 0223100038 Taxpayer name Mailing address Address(es) at this parcel 151 ANDOVER PARK E 98188 Legal description ANDOVER INDUSTRIAL PARK # 2 LESS W 402.01 FT LESS N 235 FT ASSESSOR DATA 0223100033 0223100034 0;23100033 SITE PLAN MAPQVEST. • • f l 'x y 20CY�tdnpi2'u'eat.lno.:._. :. VICINITY MAP —. 022310t1MW Map of 151 Andover Park E Tukwila, WA by MapQuest .frotti \3 154th at _9103rd t-- k U S BANK CORPORATE PROPS 2800 E LAKE ST LAKE0012 MINNEAPOLIS MN Fan* Fun Gnu 4 w I I • 55406 r 200m 01 30 n. '"f ,t o 1 3 /, tip, ���.. ti. ,/ Map Data ¢2009NAYTE9 C1 TeleA33a Parcel number 0223100038 Tax Account number 022310003805 Levy code 2390 Jurisdiction TUKWILA Present: use..._ . Bank Appraised value $920,200 ,116 Page 2 of 2 HVAC Equipment Schedule. (New) HVAC Equipment Schedule (Existing) ... Brand Lennox SEPARATE PERMIT REQUIRED FOR: Mechanical Electrical Plumbing ❑ Gas Piping City of Tukwila BUILDING DIVISION Model CHP11 -2753 Ton 20 Total CFM 8,000 EQUIPMENT SCHEDULE OSA CFM 1600 Econo. 0- 100% SP 0.5 PROJECT DESCRIPTION: 1. REPLACE (1) EXISTING 20 -TON ROOFTOP HEAT PUMP UNIT WITH NEW 20 -TON ROOFTOP GAS PACKAGED AIR CONDITIONING UNIT WITH ECONOMIZER. 2. EXISTING AIR DISTRIBUTION BEING REUSED NO WORK ". 3. PROVIDE AND INSTALL NEW 7 -DAY PROGRAMMABLE THERMOSTAT. GENERAL NOTES: 1. ECONOMIZER TO PROVIDE 100% OUTSIDE AIR WITH PARTIAL COOLING. 2, THERMOSTAT TO PROVIDE MINIMUM 5° DEADBAND. 3 INSTALL GFCI OUTLET WITHIN 25' OF UNIT. 4. ROUTE CONDENSATE TO SPLASH BLOCK. 5. PROVIDECOMMISIONING REPORT WITH OPERATIONS AND MAINTENANCE MANUALS. 6. VERIFY ALL DUCT DIMENSIONS PRIOR TO INSTALLATION. 7. ALL DUCT DIMENSIONS ARE CLEAR INSIDE DIMENSIONS. Ca • Cool 240,000 EER 8.3 Btuh -In ROOF ACCESS 0 ROOF PLAN (NTS) RTU -1 Btuh -Out AFUE Weight 3375# 1.5" GAS LINE TO METER 4 110' TO METER REVISIONS No changes shall be de amain a to the scope of work without prior approval of Tukwila Building Division. NOTE: Revisions will require a new plan submittal and may include additional plan review fees. REVIEWED FO CODE COMPLIANCE AP nnvE NOV 2 3 2009 City of Tu kwila BUILDING Iinsinlil EVIEWED FO . CO`ECOMPLI/ '4 CE . onewe JUN 14 2010 Ci of Tukn il1II JEa n lt1iioi/1p PELF COPIr Permit No. V 61) «� Plan review approval is subject to errors and omissions. Approval of construction documents does not authorize the violatio • an adopted code or ordinance. Receipt of approve 1 id 13� conditions Is acknowledged: City of lU BUILDING DIVISION RECEIVED CITY OF TUKWILA NOV , 1 2009 PERMIT CENTER REVISIONS DATE: SCALE 1 DRAWN: CHECKED: J 8 1 7 D C LU 0 CO Model No. CHP11.2763 Line voltage data - 00 Hz - 3 phase 200V . 230V 480V Compressors (2) Rated load amps (total) 39. (79.0) . 39.5/39.5 179.01 . 20.4/20.4 (40.81 Locked rotor amps (total) 229/229 (458,0) 229/229 (408.0) 116/116 . (232.0) Outdoor Coil • Fan Motors (21 Full Toad amps (total) 12.9 10.4 5.6 Locked rotor amps (total) 30 28 . 13.2 Indoor Coil Blower Motor Horsepower 6 7.1/2 • 6 7 -1/2 5 7 -1/2 Full load amps 17.6 263 15.2 22.0 7.6 11 Locked rotor amps 100.0 180.0 90.0 127.0 45.0 64.0 Optional Exhaust Fan Motor (No.) Horsepower 13)- 1/4 (3) - 1/4 (3) - 1/4 Full Toad amps (total) 4.2 4.2 22 . Locked rotor amps (total) 9.8 . 9.8 4.9 Recom. max. • fuse size (amps) Less Exhaust Fans 150 150 150 160 .. 70 70 With Exhaust Fans 150 150 150 • 160 70 . 70 Unit Power Factor . Less Exhaust Fans .88 .87 . :•: .87 .88 .87 With Exhaust Fens : .88 .87 .88 . .87 .88 .87 •Minimum Circuit Ampacity Leas Exhaust Fans 120.0 . 127.0 115.0 122,0 60.0 63.0 With Exhaust Fans 124.0 132.0 119.0 126.0 62.0 65.0 Electric Heat Model No. & Net Weight No. of Steps Volts input kw Input 8tuh Output . Total Unit & Eleotrio Heat Minimum Circuit Am aclty 5 hp 7.1/2 hp Oversized Motor Total unit watts 200 20.8 71,000 201.0 209.0 210 23.0 78,500 Unit Mounted Disconnect High Temperature Heating Ratings Power Exhaust 95.0 lb Hinged Doors 2 220 25.2 86,000 Powered Convenience Outlet tECH11. 275 -30 Adapter Curb 230 27.5 93,900 209.0 215.0 (135 lbs.) 240 30.0 102,400 Stage 1 . 2880.0 lb 2203.0 Ib 440 25.2 85,000 604.0 lb 57" 35 " 1 460 27.5 93,900 105.0 108.0 5.75 • 480 30.0 102,400 RPM tinge 780 -986 (ttt300 - 780) Optional Factory Installed t0rivea 200 31.3 106,800 238.0 .246.0 210 34.5 117,700 200/230/460v -3ph RPM range 900 - 1070 Indoor Coil 3 220 37.8 129,000 1/2 - 4 tECH11- 275-45 230 41.3 141,000 252.0 259.0 (145 lbs.) 240 45.0 153,600 15 Outdoor Coll Fans Diameter (In.) & No. of blades 440 37.8 129,000 (2) 6800 Motor horsepower 2 460 41.3 141,000 126.0 130.0 (2) 1 -1/4 (11) 16 x 20 x 1 No. & size of (ihera (in.) 480 45.0 153,600 \11 Optional Electric Heat Model No. , 200 41.7 142,300 277.0 285.0 210 48.0 157,000 Horizontal RMFH11 -276 (440 lbs.) Optional Economizer & Controls - (Net weight) . 4 220 50.4 172,000 • . Optional ., Power Exhaust: Dampers Mori&. No. - 1Net weight) tECH11. 275 -65 PED11- 276 230 55.1 188,100 297.0 304.0 1145 lbs.) 240 60.0 204,800 (3) 1/4 =MIINV Watts input (total) - 440 50.4 172,000 • and Optional Calling Supply Ret Air Diffuser (Net weight) Step -down 2 460 55.1 188,100 148.0 151.0 Transition 480 60.0 204,800 Optional Fresh Optional Automatic Electrical characteristics Air Damper & Filter Size (in.) - (Net weight) OAD11.275 (115 lbs.) 1 - 28 x 31 x 1 200 52.1 177,700 318.0 326.0 210 57.4 196,000 5 220 63.0 215,000 • tECH11. 275-75 230 68.9 235,000 342.0 349.0 1155 lbs.) 240 75.0 255,900 440 63.0 216,000 3 460 68.9 235,000 169.0 173.0 480 . 75.0 255,900 1ECH11- 275-90 8 200 62.5 213,300 367.0 386.0 210 68.9 235,000 (155 Ibs.) Accessory Accessory Economizer 80.0 lb Motorized Outside Air Damper Cooling Ratings Manual Outside air Damper Oversized Motor Total unit watts High Efficiency Motor 28,800 High Static Drive Thru the Base Electrical Integrated Part Load Value Unit Mounted Clrcul Breaker 8:3 Unit Mounted Disconnect High Temperature Heating Ratings Power Exhaust 95.0 lb Hinged Doors Total unit watts Zone Sensor 24,700 LPG Conversion Ka Powered Convenience Outlet Low Temperature Heating Ratings Adapter Curb 850.0 lb BASE UNIT WEIGHTS CORNER WEIGHTS CENTER OF GRAVITY SHIPPING NET . 2.1 Refrigerant (221 charge Stage 1 . 2880.0 lb 2203.0 Ib 701.0 Ib 675.0 Ib 421.01b 604.0 lb 57" 35 " Model Number CHP11-2753 Cooling Ratings Cooling Capacity (Btuh) 240,000 Total unit watts 28,800 EER (Btuh /Watts) 8. Integrated Part Load Value 8:3 • ARI Standard 340 Ratings High Temperature Heating Ratings Total capacity (Stub) 240,000 Total unit watts 24,700 C.O.P. 2,8 Low Temperature Heating Ratings Total capacity (8tuh) 134,000 Total unit watts 18,700 CA, P. . 2.1 Refrigerant (221 charge Stage 1 . 34 lbs. 0 oz. Stage 2 31 lbs. 0 oz. Indoor Cop Blower and Drive Selection Blower wheel nominal diameter x width (in.) 15 x 16 . Factory Inetelled tDrives Nominal motor horsepower 6 Maximum usable horsepower 5.75 • Voltage & Phase 200 /230 /480v -3ph RPM tinge 780 -986 (ttt300 - 780) Optional Factory Installed t0rivea Nominal motor horsepower 7.1/2 Maximum usable horsepower 8.63 Voltage & Phase 200/230/460v -3ph RPM range 900 - 1070 Indoor Coil Net face erea`(eq. ft.) 23.6 Tube diameter lin.) & No. of rows 1/2 - 4 Fine par Inch 15 Outdoor Coil Net (ace are (sa. h.) 38.9 Tube diameter (in.) & No. of rows 1/2 - 4 Fine par inch 15 Outdoor Coll Fans Diameter (In.) & No. of blades 12) 26 - 5 Air volurne (cfm) (2) 6800 Motor horsepower (2) 1 Motor watts 12) 1000 Condensate drain slze mpt (in.) 1 l (2) 1 -1/4 (11) 16 x 20 x 1 No. & size of (ihera (in.) Net weight of basic unit fibs.) (1 Package) 2900 \11 Optional Electric Heat Model No. , ECH11 -275 kw input range 30- 45- 60-75.90 . Optional Roof Mounting Frame - (Net weight) Standard RMF11.276131lbs.) Horizontal RMFH11 -276 (440 lbs.) Optional Economizer & Controls - (Net weight) . ' REM011M -276 (290 lbs.) Optional Gravity Exhaust Damper - (Net weight) - GED11 -276 (30 lbs.) • . Optional ., Power Exhaust: Dampers Mori&. No. - 1Net weight) PED11- 276 Exhaust Fens. Diameter (in.) & No. of blades (3) 18 - 5 Total air volume (cfm) 7050 Motor horsepower (3) 1/4 =MIINV Watts input (total) - 1100 • and Optional Calling Supply Ret Air Diffuser (Net weight) Step -down RT01I.275 1403 Ibe.) Flush FD1I- 275 (363 lbs.) Transition .SRT11 -276 (80 Ibs.) Optional Fresh Optional Automatic Electrical characteristics Air Damper & Filter Size (in.) - (Net weight) OAD11.275 (115 lbs.) 1 - 28 x 31 x 1 OADI1 Damper Kit - (Net weight) 88G13 (15 Ibe.) 200 to 460 volt - 60 hertz - 3 phase Voyager YCD Items: YCD_ -1 (This item Is not 'In Job') 7/13/2009 8:21:20 AM CORNER WEIGHT WEIGHT DATA BASE UNIT: ECONOMIZER: RIGGING AND CENTER OF GRAVITY NEW UNIT): #2203 #80 POWER EXHAUST: #95 ADAPTER CURB: #850 TOTAL W /ACC: #3328 Comfort Mechanical - WFB Tukwila INSTALLED OPTIONS NET WEIGHT DATA 0 TRANS" NOTE: 1. CORNER WEIGHTS ARE GIVEN FOR INFORMATION ONLY. 2. TO ESTIMATE SHIPPING WEIGHT OF OPTION /ACCESSORIES ADD 5 LBS TO NET WEIGHT. 3. NET WEIGHT OF OPTIONAL ACCESSORIES SHOULD BE ADD TO UNIT WEIGHT WHEN ORDERING FACTORY INSTALLED ACCESSORIES. 4. WEIGHTS FOR OPTIONS NOT LISTED ARE < 5 LBS. 5. WEIGHT ARE OF BASE UNIT ONLY. FOR TOTAL WEIGHT, 10 DIGIT FACTORY INSTALLED OPTION (ECONOMIZER AND /OR OVERSIZED MOTOR OR FIOP /ACCESSORY WEIGHT MUST BE ADDED. TOPSS Dimension Drawing ALLW ELHTS AND D1iENSDNS ARE APPROXIMATE. CERTFED PRNTS ARE AVAIABLE UPON REQUEST. Page: 4 SPECIFICATIONS *Rated In accordance with /RI Standard 340. • Cooling Ratings - 95°F outdoor sir temperature and 80 °F db /67 °F wb entering Indoor coil sir, minimum external duct static pressure. High Temperature Hs:ting Ratings - 47°F db /43°F wb outdoor air temperature and 70 °F db entering Indoor call air. Low Temperature Heating Ratings - 17 °F db /15°F wb outdoor air temperature and 70 °F db entering Indoor coil dr. tUsing total air volume end system static pressure requirernenttt determine from blower performance tables rpm and motor output required. ttMotor pulley turnlshed with unit for field Installation, If rsquked. WEIGHT DATA (EXISTING UNIT): BASE UNIT: #2900 ELECTRIC HEAT: #155 ECONOMIZER: #290 EXHAUST DAMPER #30 TOTAL W /ACC: #3375 -31f ELECTRICAL DATA 'Refer to National Electrical Code manual to determine wire, fuse and disconnect she requirements. NOTE - Extremes of operating range are plug and minus 10% of line voltage. • OPTIONAL ELECTRIC HEAT DATA 'Refer to National Electrical Code manual to determine wire, fuse and disconnect she requirements. Use wires suhabie for at least 167 °F. 1 May be used with two stage control. - 31g - REVIEvvED FOR CODE COMPLIANCE app oven Li 2 3 Luu9 City of Tukwila BUILDING nlnngInN JUN .142010 �GoR- �3y RECEIVED . CITY OF TUKWILA NOV 1.2 2009 PERMIT CENTER r REVISIONS Z <0 ii Iw L L.) i F.... 0 o: II': Li isk 0 4 3 U mi 0 W oo -; D (3- 0 ) I- [ < Z act' Q D J m Q Y D F- DATE; SCALE •DRAWN CHECKED M2