HomeMy WebLinkAboutPermit 91-01-R - GRUNDSTEIN LEON / GENCOR DEVELOPMENT - NORTH HILL OFFICE BUILDING REZONE91-1-r 5900 southcenter boulevard
91-01-cpa
GENCOR DEVELOPMENT NORTH HILL OFFICE BUILDING REZONE
ZONING CODE AMENDMENT
COMPREHENSIVE PLAN AMENDMENT
COMPREHENSIVE LAND USE PLAN AMENDMENT
COMPREHENSIVE LAND USE PLAN AMENDMENT
COMPREHENISVE PLAN AMENDMENT
6200 Southcenter Boulevard • Tukwila, Washington 98188
C)
M E M O R A N D U M
TO: Rick Beeler, Planning Director
FROM: Ron Cameron, City Engineer
DATE: January 9, 1992
SUBJECT: North Hill Office Rezone - Environmental ZONING CODE AMENDMENT COMPREHENSIVE PLAN AMENDMENT COMPREHENSIVE LAND USE PLAN AMENDMENT
Per the attached November 19, 1991 Memorandum, the North Hill rezone
iaas approved, based on 430 ADT. As stated in the 11/19/91
Memorandum, we need to approve future development with that limit in
mind and require monitoring of ADT peak on a quarterly basis for the
first two years and annually thereafter. If the monitoring program
identifies the 430 limit being exceeded, the development shall be
required to provide the necessary corrections to reduce the ADT
volume below the 430 limit.
It is my understanding, the original SEPA determination provided a
225 ADT limit. Per review of the March 28, 1990 Entranco Engineers
study and January 30, 1991 trip generation comparison (Entranco
Project No. 90809 -6) 430 ADT limit was accepted. Therefore,
recommended is SEPA be modified to allow adjustment from 225 ADT to
430 ADT with the above monitoring conditions provided as a
requirement. The change in ADT does not have a significant impact
nor warrant any SEPA modifications other than establishment of the
monitoring program (at the developer's sole expense).
Attachment: North Hill Study 11/19/91 Memorandum
xc: Phil Fraser
John Pierog
Jack Pace
'Development File: North Hill Office
Read File
PF /amc:l0:nohills
Phone: (206) 433-1800 • City Hall Fax (206) 433 -1833
[JAN 14 1992
CITY OF TUKWILA
PLANNING DEPT.
John W. Rants, Mayor
3111E
1- -----
JAN 14 1992
CITY OF TUKWILA
PLANNING DEPT.
CC: Phil Fraser
John Pierog
Jack Pace
City of Tukwila
PUBLIC WORKS DEPARTMENT
6300 Southcenter Boulevard
Tukwila, Washington 98188
(206) 433 -0179
Ross A. Eornst, P.E. Director
File: North Hills Office Development
MEMORANDUM
TO: Rick Beeler, Planning Director
FROM: Ron Cameron, City Engineer
DATE: November 19, 1991
SUBJECT: North Hills Office Rezone
1<o(
The North Hills rezone was approved based on 430 ADT. The approval
recommendation is based on that limit. As stated 4 -5 times to Council.
We need to approve future development with that limit and require monitoring of
ADT, peak on quarterly basis first 2 years, then annually. Correction to limit
to the 430 required.
RMC /kjp
Attachment: North Hills Study
Collision Diagram presented at Council
January 9, 1992
City of Tukwila
6200 Southcenter Boulevard • Tukwila, Washington 98188
Leon Grundstein
750 6th Street South, Suite 200
Kirkland, WA 98033
SUBJECT: North Hill Office Building, 5900 Southcenter Blvd.
(PC No. 89 -399) Revised Submittal Deadline
Dear Mr. Grundstein:
It has come to my attention that past deadlines for the submission of
the information and revised plans requested by John Pierog of this
office, in his December 10th letter, will not be met.
During a telephone conversation you had with John on 1/3/92 you
indicated that you thought you could have your resubmittal ready by
January 20, 1992. I realize that the vacation of the easement upon
which the proposed building would encroach may take some time to
finalize. However, prior to that time, a written commitment to that
effect between the parties involved will suffice for our purposes.
We are requesting that you direct whatever effort is necessary to
have your submittal to this office no later than January 20, 1992.
If you are not able to meet this deadline, the permit application
package we now have will be returned to the City Department of
Community Development.
Also, please note the Department of Community Development requires
the Traffic Analysis be amended with the following:
The mitigated Determination of Non - Significant issued on
October 1, 1990 shall include the changes in the ADT from
225 to 430 ADT. Also the applicant /owner shall provide,
at their expense, monitoring of ADT peaks on a quarterly
basis for the first two years, then annually, by a qualified
Traffic Engineer, and transmit the results of each monitoring
to the City Engineer.
Phone: (206) 433 -1800 • City Hall Fax (206) 433 -1833
John W. Rants, Mayor
If I can be of assistance or if you have any questions concerning the
above, please call me at 433 -0179.
Sincerely,
Phil Fraser
Senior Engineer
Public Works Department
xc: John Pierog, Associate Engineer
Darren Wilson, Assistant Planner
Duane Griffin, Building Official
Permit Coordinator
Development File: North Hill Office
Read File
PF /amc:9:office
CITY OF TUKWILA
AN ORDINANCE OF THE CITY COUNCIL OF THE CITY
OF TUKWILA, WASHINGTON, RELATING TO ZONING
CLASSIFICATION FOR "NORTH HILLS OFFICE"
AMENDING TUKWILA MUNICIPAL CODE CHAPTER
18.08.030 (AMENDING CERTAIN PROVISIONS OF
ORDINANCE NO. 1247)
WHEREAS, the proposed zoning complies with the Tukwila Comprehensive Plan
designation of commercial; and
WHEREAS, the City Council adopted the Findings and Conclusions contained in the
Staff Report, dated September 26, 1991, for approval of a rezone classification from P.O.
(Professional Office) to C -1 (Neighborhood Retail); and
WHEREAS, the City Council reviewed and approved a zoning classification of C -1
(Neighborhood Retail) on October 21, 1991; and
WHEREAS, the amendments set forth below are necessary to correct the Tukwila
Zoning Map as orig adopted in Ordinance No, 1247, 1982);
NOW, THEREFORE, THE CITY COUNCIL OF THE CITY OF TUKWILA,
WASHINGTON, DO HEREBY ORDAIN AS FOLLOWS:
Section 1. Zoning Map Amendment, The Tukwila Zoning Map originally adopted in
Ordinance No. 1247 is hereby amended to include the area known as North Hills Office,
bounded at 5900 Southcenter Boulevard, except that property currently containing the North
Hills Apartments (as shown on Attachment C). A rezone classification of C -1 (Neighborhood
Retail) is hereby adopted for the aforementioned North Hills Office area.
Section 2. Severability. If any section, sentence, clause or phrase of this ordinance
should be held to be invalid or unconstitutional by a court of competent jurisdiction, such
invalidity or unconstitutionality shall not affect the validity or constitutionality of any other
section, sentence, clause or phrase of this ordinance.
Section 3. Effective Date. This ordinance shall take effect and be in full force five (5)
days after publication of the attached summary which is hereby approved.
PASSED BY THE CITY C_ OLj�iCIL C TY OF TUKWILA, WASHINGTON,
at a Regular Meeting thereof this' day o 1991.
ATTEST /AUTHENTICATED: -
' -cL G -cam
(3ne E. Cantu, City Clerk
APPROVED AS TO FORM:
OFFICE OF THE CITY ATTORNEY:
B J 1/1 11
FILED WITH THE C ' 'Y CLERK: 1 / - N - 7/
PASSED BY THE C COUNCIL; / / • 9 �/
PUBLISHED: //- 7- 7/
EFFECTIVE DATE: / /- i2- 1/
ORDINANCE NO.: no /U
WASHINGTON
NO. _16/10
an Dusen, Mayor
16710 0 3 5 "Z - °0
0 35'/
L 351700 ozoZ 000
O
}
iwyST
Go..G. Q!r
G....At+
•a+nT•
'ALT.
arK.L�r s .i
Cla.7R'
�.wfrri.rT
Y
ATTA
r .
LCM /clh
11/21/84
WASHINGTON
ORDINANCE NO. 2,
•
••
tvc — 4
G t
a TY OF TUKWHJz
0
85/01/ti
RE:�:L F
CA'= I1SL
AN ORDINANCE OF THE CITY OF TUKWILA, WASHING-
TON, AMENDING THE OFFICIAL ZONING MAP ADOPTED
PURSUANT TO SECTION 18.08.030 OF THE TUKWILA
MUNICIPAL CODE BY RECLASSIFYING CERTAIN PROP-
ERTY WITHIN THE CITY KNOWN AS THE NORTH HILL
REZONE PROPERTY FROM HIGH DENSITY MULTIPLE
RESIDENCE (RMH) TO PROFESSIONAL OFFICE (P -0).
7.•'f';i
WHEREAS, the Tukwila Planning Commission cor;lucted a
L)
V) public hearing for the purpose of considering a proposal to revise
r4 the zoning classification of certain property from high density
v 11 , multiple residence (RMH) to professional office (P -O) known as the
OD
North Hill Rezone, City File No. 84 -11 -R, and at the conclusion of
said hearing and after deliberations upon the proposed rezone the
Planning Commission forwarded its recommendation to the City
Council, and
WHEREAS, the City Council . also conducted a public
hearing on the proposed zoning map amendment which was held on
November 26, 1984, and at the .: onclusion of said hearing having
determined that the proposed zoning map amendment should be made,
WHEREAS, the City's Responsible Official has determined
that the proposed zoning map amendment will not result in signi-
ficant impacts upon the environment and a final declaration of
nonsignificance has been issued, now, therefore,
THE CITY COUNCIL OF THE CITY OF TUKWILA, WASHINGTON, DO
ORDAIN AS FOLLOWS:
Section 1. The City's official zoning map adopted pur-
suant to Section 18.08.030 of the Tukwila Municipal Code is hereby
amended by revising the zoning classification of certain property
within the City described on Exhibit A, attached hereto and incor-
porated herein by this reference as if set forth in full, commonly
known as the North Hill Property, City File No. 84 -11 -R, from high
density multiple residence (RMH) to professional office (P -O).
40391
►:4 4.4:; • OC
55
BY
Section 2. The findings and conclusions of the City
Council with respect to the zoning map amendment implemented by
this ordinance are attached as Exhibit B and are incorporated
herein as if set forth in full.
Section 3. The City Planning Director is hereby
instructed to revise the City's official zoning map in accordance
with Section 1 of this ordinance.
Section 4. This ordinance shall be in full force and
effect five (5) days after passage and publication as provided by
law.
• PASSED BY THE CITY COUNCIL OF THE CITY OF TUKWILA,
WASHINGTON, at a regular meeting thereof this 17th day of
December , 1984.
ATTEST /AUTHENTICATED:
• CT Y CL RK, mAXINi ANDERSON
APPROVED AS TO FORM:
OFFICE 9 THE CITY ATTORNEY:
FILED ITH THE CITY CLERK: 5/9/84
PASSED BY THE CITY COUNCIL: 12/17/84
PUBLISHED: 12/26/84
EFFECTIVE DATE: 12/31/
ORDINANCE NO. 1339
APPROVED:
M 0 , " Y L. VAN DUSEN
EXHIBIT A TO ORDINANCE 1339
THAT PORTION OF LOT 11 OF INTERURBAN ADDITION TO SEATTLE, AS PER VOLUME 10
OF PLATS, PAGE 55, RECORDS OF KING COUNTY, LYING NORTH OF THE NORTHERLY
LINE OF PRIMARY STAlE HIGHWAY ROUTE 1, AS CONVEYED TO THE STATE OF
WASHINGTON, BY DEED RECORDED UNDER RECORDING NO. 5473599;
EXCEPT THE EAST 450.86 FEET AND THE NORTH 255.03 FEET THEREOF;
SUBJECT TO AND TOGETHER WITH EA3EMENTS AS RECORDED IN KING CO. A.F.
#6007217 AND #7502130412, RESTRICTIONS AND RESERVATIONS OF RECORD, IF ANY.
SITUATED IN THE CITY OF TUKWILA, COUNTY OF KING, STATE OF WA.
C
EXHIBIT B TO ORDINANCE NO. 1339
Findings & Conclusions of Tukwila City Council
Concerning the North Hill Associates Rezone
I.
FINDINGS
A. Western Pacific Properties is proposing to develop a three
story office building consisting of approximately 14,500
square feet on the vacant property immediately east of the
existing Arco AM -PM Mini Mart at approximately 5900 South -
center Blvd. Currently, the property is being utilized for
an informal parking lot. In order to accomplish the proposal
the applicant is requesting rezoning of the property from the
existing zoning of High Density Multiple Residence (RMH) to
the Professional Office (P -O) zoning classification. The
w4 property which is the subject of the rezone request consists
OI of approximately .87 acre of a 1.94 acre parcel owned by
C the applicant.
wi
wl B. Board of Architectural Review of the specific design of the
building and site plan will occur subsequent to the final
action on the rezone.
C. The Comprehensive Land Use Plan Map designate the subject
property "Commercial" without specific development considera-
tions.
D. A Final Declaration of Nonsignificance was issued for the
proposal.
E. The property adjacent_ to the subject property on the west is
zoned Local Retail (C -1) and is designated "Commercial" with-
out special development considerations by the Comprehensive
Land Use Plan Map. The property immediately to the north of
the subject property is zoned Multiple Residence High Density
(RMH) and is designated by the Comprehensive Land Use Plan
map as high density residential without special development
considerations. This property is also owned by the appli-
cant. The property to the east of the subject property is
also designated high density residential without special
development considerations. The present zoning of this prop-
erty is Low Density Apartments (R -4). The subject property
is bordered on the south by Southcenter Boulevard which is
adjacent to the I -405 freeway.
F. An Arco Mini Mart has been constructed on the property adja-
cent to the subject property on the west. Other adjacent
properties are undeveloped. An office building development
is located to the east of the easterly abutting property.
G. A hillside and retaining wall are located at the northern
end of the subject property. The remainder of the subject
property was excavated some time ago and is presently rela-
tively flat.
II.
CONCLUSIONS
A. The proposed zoning reclassification is in conformity with
the City's Comprehensive Land Use Policy Plan, the provisions
of Title 18 of the Tukwila Municipal Code and in general will
serve the public interest. Specifically, the proposed
reclassification is consistent with the following goals and
policies of the Comprehensive Land Use Policy Plan:
1. General Goals: Goals 1, 5 and 6 (pages 12 and 13).
2. Natural Environment: Goals 1, 2 and 3 (page 15); Objec-
tive 1, Policies 1 and 3 (page 24); Objective 3 (page
25); Policies 1, 2, 3 and 4 (page 26); Objective 6 (page
28); Policy 1 (page 29); Objective 8 (page 30).
3. Open Space: Goal I (page 16); Policy 1 (page 34).
4. Commerce /Industry: Goals 1, 2 and 3 (page 18); Objec-
tive 1, Policies 1 and 2 (page 60); Objective 3,
Policies 1 and 2 (page 64); Objective 4 (page 65);
Policies 1, 2 and 3 (page 65); Objective 6, Policies
1 and 3 (page 67).
B. The proposed zoning reclassification has been supported by
submittal of architectural site plans showing proposed devel-
opment and its relationship to surrounding areas. The pro-
posed development is consistent and compatible with surround-
ing zoning and development, including the multi - family devel-.
opment to the north, as a result of natural separation pro-
vided by the hillside to the north of the property, scale of
the proposed development, access points and proposed land-
scaping.
C. The proposed reclassification is compatible with the City's
Comprehensive Land Use Policy Plan. The applicant is there-
fore not required to demonstrate need for the request pur-
suant to Section 18.84.030(3) of the Tukwila Municipal Code.
. D. The proposed office development will result in less traffic
impact than multi - family development under the existing
zoning.
- 2 -
City of Tukwila
PUBLIC WORKS DEPARTMENT
6300 Southcenter Boulevard
Tukwila, Washington 98188
(206) 433 -0179
Ross A. Earnst, P.E. Director
File: North Hills Office Development
MEMORANDUM
TO: Rick Beeler, Planning Director
FROM: Ron Cameron, City Engineer
DATE: November 19, 1991
SUBJECT: North Hills Office Rezone
The North Hills rezone was approved based on 430 ADT. The approval
recommendation is based on that limit. As stated 4 -5 times to Council.
We need to approve future development with that limit and require monitoring of
ADT, peak on quarterly basis first 2 years, then annually. Correction to limit
to the 430 required.
RMC /kjp
Attachment: North Hills Study
Collision Diagram presented at Council
CC: Phil Fraser
John Pierog
Jack Pace
ENTRANCO
November 4, 1991
Mr. Ron Cameron
Traffic Engineer
City of Tukwila
6300 Southcenter Boulevard, Suite 101
Tukwila, Washington 98188
Re: Collision Diagram at the Intersection Vicinity of Southcenter Boulevard/
North Hills Apartments Driveway
Entranco Project No. 90809 -06
Dear Ron:
Enclosed you will find the collision diagram summary for the Southcenter Boule-
vard /North Hills Apartments driveway intersection and mid -block segments between
Macadam Road and 61st Avenue South. This diagram was completed based on the •
request from Tukwila City Council for review of historical accident data in the study
area. The data reviewed includes all accidents reported to the City of Tukwila during
the three -year time period of October 1988 to October 1991.
The table below shows a summary of the accident analysis conducted for the refer-
enced location.
Accident Type October 1989 October 1990 October 1991
EB Rear End 8 6 10
WB Rear End 2 2 6
SB Left Turn 7 4 3
SB Right Turn 0 1 0
Miscellaneous 2 0 5
Totals 19 13 24
Please feel free to call me if you have any questions regarding this information.
Sincerely,
ENTRANCO
• Ara1 ~!!
Sher • n D. G •'• ng ./
Project Engineer
SDG:dcn
Enclosures
WASHINGTON • ARIZONA • CALIFORNIA
Accident Data Summary
(October 1988 to October 1991)
ENGINEERS • SCIENTISTS • PLANNERS • SURVEYORS
12 Month Period Endino
10200 NE 8TH STREET. SUITE 300
BELLEVUE. WA 98004
(206) 454-5603
FAX: (206) 454.0220
ti U.•._. v./
1•30
f -1L• t1
1710
t k / IV
r - #5
#73s
SYMBOLS
9 1-7, 4- 91 ,
• I` ;7(6
Z.Iio
tr -21-
1 1 5 0
11- 91-111 )t
Ic a
-+ Moving VCi11cIC
» > docking Vehicle
-a- -- Non- Involved Vehicle
?F --- Pedestrian
L� Parked Vehicle
o Fixed Object
O Fatal Accident
O Injury Accident -
TYPES OF COLLISIONS
- -t -- Reor End
-- �---�- Head On
. — Side Swipe
•fib` Out of Control
_b • Left Turn
i t- Right Angle
. ri4
SHOW FOR EACH
ACCIDENT
I. Day, Dote and Time
2. Weather and Rood
Surface - if Unusual
Condition Existed
3. Nile — If Between
Dusk and Dawn
I D
S
S oirrvIcMpsC Svc ; --?
(Name)
INTERSECTION 1J°a7H Dias pFtrvelo
and - sv u - s1iCeNTEP 13 LVD
PERIOD "JAW. (3I — oa: ctt
from 0 ittCS
to
Fxr• :I >
YI oa I
/ DM
SYMBOLS
k 1-t--9 0
141
1/- t
1135
11.13.4
•73Y
)
-� Moving Vehicle
+ » > Backing Vehicle
-4-- -- Non - Involved Vehicle
)f- --- Pedestrian
Parked Vehicle
0 Fixed Object
O Fatal Accident
0 Injury Accident
E +r- IS
nz�
TYPES OF COLLISIONS
- f-t-s— Rear End
• Head On
Side Swipe
fib` Out of Control
Left Turn
. r Right Angle
/1-12 -fo
/Lio
l 7 -1s -qo
SHOW FOR EACH
ACCIDENT
1. Day, Date and Time
2. Weather and Road
Surface - if Unusual
Condition Existed
3. Nile - if Between
Dusk and Down
x� tr-+t-9D A >
1311 0 rho
4•11
150
12
h1?
/110-90 X —fit
1210
trio tIttNtf SWQ _.
(Nome
I NTERSECTION_RbatLii ssz u)fl1
and tstirV JMVD
PERIOD...7&A -3 � q
f rom__Di1 ES
to ZLI t flfS
/frar
13 eo
3 ' s.° it
rtie
ryry
1
!r
SYMBOLS
-•—• Moving Vehicle
Backing Vehicle
-a - -- Non - Involved Vehicle
Pedestrian
Pocked Vehicle
Fixed Object
Fatal Accident
0 Injury Accident
TYPES OF COLLISIONS
-�—tr Rear End
-4-4-- Head On
<= Side Swipe
-°rt►` Out of Control
_�..r Left Turn
Right Angle
SHOW FOR EACH
ACCIDENT
Day, Date and Time
2. Weather and Rood
Surface 7 if Unusual
Condition Eicisted
3, Nile - if Between
Dvsk and Dawn
s -11 -n
lsso
•
I•rY•1? x
IT'D
Nye
A >
•
r 11 - 1` -114
n•t
(Name
PERIOD ccr 66 — Ca— 69
INTERSECTION t gini 1Ittks vRtrEuxr(
and. iJ 3(-E 11 .f ''•
from OiIKS
to 2rlcQif
BACKGROUND
October 21, 1991
City Council
.TO:
FROM: Darren,Wilson, DCD`
RE:
Rezone Approval North Hills Office (91-1-R) from PO
(Professional Office) to C -1 (Neighborhood Retail),
located at 5900 Southcenter Boulevard.
Since 1984, there have been three different'
for this site. The last project raCApp
r ral�SRevi.M °fen �rjuly 5, x1990 f or
�A a
IAttachssen C reflect the app roved? : 'r' i p
/On June ;18, 1990,x, the City ��Councils appro; .,
request for a k waiver from the sensitive ,ar
sen i
that °the re quest s could°'be" process d.
design proposals
► � thek�taoard H of
is bii`i ding.
4111 ' D�Cr x,1990, the CittrCouncil
request r for ,a , resone from UP-O '
(:Neighborhood >atita i) die;�to tr affic is p a �t
10 J anuary 3.0 rrf19.9 the
information, ' pert a i ning ,to : t
Entranco Engineers, Inc..
3Ron ICaareronk dats4 Sept
4i11 , have Fmeaaur o
C)
t h�ipplicant' : s
u a s moratorium 'so
V14P Meant,' s
lice) 66 C -1`
tional
hen traffic =analysis, prepared, by
ms�so from , th Cit ed Engin er,
?� 1991 wit' ted" °:that a -t m rezone
ratfic ." >r (See Attachment
MEMORANDUM
To The City Council
91 -1 -Rs N. Hills.Office
Page 2
' R&ZONIVCRITERI11, > .
The burden of proof in demonstrating that the change is
appropriate lies solely upon the proponent. Generally, the .
more dramatic the change, the greater: will be the burden of
showing that the proposed change is in conformance with the
Comprehensive Plan as implemented by the Zoning Ordinance.
The proponent must clearly show why the rezone application
should be granted. The 3 rezone criteria contained in the
Zoning Code section 18.84.030 and 3 criteria based upon case
law study.
TIC 18.84.030 (1) The use change in zoning requested shall be
in conformity with the adopted Comprehensive Land Use Policy
Plan, the provisions of this title, and public interest;
TIC 18.84 030 (2) The use or , change : in zoning requested in . the
zoning map or this title for the establishment of commercial,
industrial, or residential use shall be supported by an
architectural site plan showing the proposed developsrnt and
its. relationship to surrounding area as set forth in the
application form
T1C;' 18.84.030, (3) When tha request is not in . agr�esaent 'with
the Comprehensive Land :Use Policy Plan, the applicant shall
provide evidence to the' City Council's satisfaction that there
.is :an additional need for. the request land Classification;
(4) Significant changes•'have .occurred -in the character,
conditions or surrounding neighborhood • that justify Or
:.otherWise subetantiats the_ proposed rezone..
(5) The proposed rusone is in the best::interest''of the public
health, safety,: and welfare as compared:to hardship,. such as
diainutioa. property value, ieposed on the individual
property owner.
(6 The •unimproved subject property is, unsuitable, for the
purpose, for which.' it has , been coned, considered in the context
of the length of tier the property has remained unimproved and'
land developsent in the surrounding area.
MBNORANDUK
To The City Council
91 -1 -Rs N. 8ills'
Page 3
<: RaUOMai . .. PROCEDDRES
.Section .18::,84: :0.50 Rosonok Procedures s City Council 1�iction.
"lollowinq:tha'hiaring the:city council may.. accept, reject or
g.iimodifyA<the ,i- recommendation of the planning commission or. :the
,C ty.,.council,� may refer the Matter to the planning commission
!for,,th ir` reconsideration. If the applications returned to .
th .n nq : commission for reconsideration, and .the
application' is returned to the city council shall grant, 'deny,
or.amnd the planning commission recommendation within thirty
A 4°'
�l ,nom 6. days : a itmr receipt of the recommendation.
e
• \16- rs, PLANNING COMMISSION
14710 ` I jd' Based on the Findings and ,Conclusions contained in the Staff
• ft Report, the Planning Coos isaion recommended. approval . by- the City
R�
ice(
� • A / �+►
OAP 04 , efit° fra tt,ple.
• AA to'
oqc 04= **tit ob
o itA t o ,s
f " to& "'"
ttio'
Planning Commission Minutes
September 26, 1991
91-1-R North Hills Office
Darren Wilson presented the staff report. Staff stated that the applicant for this project,
Gencor, is requesting a rezone from P.O. (Professional Office), to C-1 (Neighborhood
Retail). The site is located at 5900 Southcenter Blvd. (North Hills Office/Gencor
Development). The Comprehensive Plan designation for this area is commercial and the
existing zoning is P There was a Mitigated Determination of Non-Significance issued in
October 1990.
Approximately a year ago the Planning Commission recommended approval of the rezone
however, the City Council denied the rezone due to the traffic analysis. The applicant has
come back and submitted additional information pertaining to the traffic analysis and the
concerns of the City CounciL Staff stated that the rezone complies with the Comprehensive
Land Use Policy Plan, in addition, the rezone is not considered to be detrimental to the
public welfare. This site received Board of Architectural Review site plan approval in July
of 1990 and the plan will comply with the C-1 zoning designation. Through the
Environmental Review process, there were no significant impacts that were identified,
however, it is a steep site. The Council approved the waiver from the Sensitive Areas
Ordinance to process the SEPA determination. The applicant has provided additional
landscaping, as well as a geo-technical soils report that exceed the SAO requirements as they
are today. Ron Cameron, City of Tukwila Engineer, has provided a letter which 'indicates
that the rezone will not have any measurable effects on traffic. This rezone would not ;
create spot zoning.
This site is unique in that to the north is a steep slope, but is buffered by, the multi-family
development, to the east is landscaping which serves as a buffer between the existing office
building, and to the west are commercial uses. With regard to the requirement differences
between P.O. and C-1, the height requirements in P.O. are the same as that required in C-
1; the landscaping requirements in P.O. exceed that required in C-1, the applicant has
provided additional landscaping which exceeds the C-1 requirements; the parking
requirements in P.O. and Col are exactly the same, with the exception that if the commercial
proposal adds a restaurant, then the parking requirements would increase based upon the
square footage of the restaurant area and at this time, the commercial request does not
include any restaurant development. As a recommendation, the staff recommends that the
Planning Commission adopt the findings and conclusions of the staff report and recommend
approval of the request from P.O. to C-1.
Mr. Flesher asked what site was to the west of this proposal.
Staff indicated that the 'Denny's" restaurant and "A.M./P.M." store.
Mr. Haggerton asked why the Council did not approve the rezone.
ATTACHMENT B
ENTRANCO
October 16, 1991
Mr. Ron Cameron
City Engineer
City of Tukwila
6300 Southcenter Boulevard, Suite 101
Tukwila, Washington 98188
Re: Supplemental Traffic Analysis for the Proposed North
Hills Development Site in Tukwila, Washington
Entranco Project No. 90809 -06
Dear Ron:
Existing Conditions
WASHINGTON • ARIZONA • CALIFORNIA
ENGINEERS • SCIENTISTS • PLANNERS • SURVEYORS
10900 NE 8TH STREET, SUITE 300
BELLEVUE, WA 98004
(206) 454.5600
FAX: (206) 454 -0220
RECEIVED
OCT1 6 1991
TUKWILA
PUBLIC WORKS
This letter documents the supplementary traffic analysis performed at your request
for the North Hills Development site in Tukwila, Washington. The proposed site is lo-
cated on the north side of Southcenter Boulevard west of the 61st Avenue South
bridge and adjacent to the existing Arco AM /PM Mini Mart site. The existing North
Hills Apartment access driveway separates the Arco site from the proposed site.
(Refer to figure 1 of March 28, 1990 letter report; appended hereto.)
A previous study for the site was conducted in March 1990 assuming a general of-
fice use for the development (see attached March 28, 1990 letter report). The pro-
posed use has been revised for general retail, thereby, constituting the request for
this supplemental analysis.
Access to the site will remain via a single access driveway that will ingress and
egress the North Hills Apartment driveway. The previous study (referenced above)
for the general office use mentions an additional access driveway on Southcenter
Boulevard, however, this driveway has since been eliminated from the site plan for
its current proposed use.
The existing conditions for the adjacent arterial street system has remained for the
most part unchanged, although, it would not be unreasonable to assume that some
background growth in traffic volumes may have occurred in the past year.
A significant change, however, has been made to the laning designation for west-
bound Southcenter Boulevard. Since the traffic impact analysis was conducted for
the proposed general office use, the laning on Southcenter Boulevard has been
modified to allow traffic in the westbound lane just south of the north curb lane ac-
cess to northbound 1 -5. This revision is significant because traffic destined for 1 -5
now distribute more evenly between the curb lane and adjacent lane, thereby, lower-
ing the traffic volumes in the curb lane and creating more available gaps to access
Southcenter Boulevard from the North Hills Apartments driveway. This would be
most beneficial for site traffic destined westbound on Southcenter Boulevard or from
the North Hills Apartments.
€'.
Planning Commission Minutes
September 26, 1991
Staff stated that the rezone was denied by the Council because they wanted additional
information regarding the . traffic analysis. The applicant, ` in turn, has provided the
information which was : required by the City Engineer and they do not feel that the
rezone would have any measurable impacts on traffic.
Leon Grundstein, Gencor Development, 750 6th St S., Kirkland, WA:
He stated that the retail proposal they have planned for the site would compliment the uses
on the hillside due to the vast number of residential : units. He stated it was not their intent .
to put in a restaurant. The building is designed to accommodate. either professional use or
retail use such as a dry cleaner or insurance office. The only issue which arose when the
proposal went to the City Council, was does the retail use promote additional traffic, and
Mr. Grundstein stated that in fact it reduces the net amount of traffic which goes in and out
of the site due to pass -by traffic,
Sherman Gong, Entraco Engineers, Consultant for Gencor•.
A traffic analysis was conducted in March, 1990 based on a office use and found that there
were insignificant impacts to the street system. Then earlier this year, Mr. Grundstein
requested another study based on a commercial use. Again, they found that the traffic that
would be generated by a retail use would be approximately the same as that of a office use
Mr. Malin asked what the duration of the second analysis was.
Mr. Gong stated that the analysis typically analyzes the peak hour conditions on any given
day.
Mr. Malina asked how the traffic figures were generated.
Mr. Gong stated that the traffic . numbers are based on rates that are published in the
Institute of Transportation Engineers Manus
Steve Friedman, Gencor Development, 750 6th St. S., Kirkland, WA:
He stated that they had the traffic analysis when they approached the Planning Commission
the first time, however, the Planning Commission never asked for the information, therefore
it never entered the record. The traffic information then couldn't be discussed at the City
Council meeting because it wasn't in the record for the Planning Commission and new
information was not allowed to be submitted.
Don Moody, 1401 57th Ave. S.:
Mr. Moody stated that he was a real estate agent and he wanted to confirm that the demand
for commercial use sites is high in comparison to that of office use.
Planning Commission Minutes
September 26, 1991
Rich Cato
Mr. Cato stated that his father has been in Tukwila for over 50 years and has been planning
for his retirement. Their income was based on the earnings from this piece of property. Mr.
Cato stated that commercial usage of the site would be better than the office usage.
Mr. Flesher closed the public hearing at 9:19 p.m.
MR. MAUNA MOVED TO APPROVE 91 -1 -R: NORTH HILLS OFFICE, TO ACCEPT
STAFF'S RECOMMENDATIONS AND ADOPT ITS FINDINGS AND CONCLUSIONS
AND RECOMMEND APPROVAL OF THE REQUEST FROM P.O. TO C-1. MR. GOMEZ
SECONDED THE MOTION; MOTION PASSED UNANIMOUSLY.
Mr. Flesher called for a ten minute recess at 9:20 p.m.
ENTRANCO
September 26, 1991
North Hills Office Building Site
Tukwila, Washington
Entranco Project No. 90809 -06
AM Peak
Noon Peak
PM Peak
Daily
AM Peak
Noon Peak
PM Peak
C
WASHINGTON • ARIZONA • CALIFORNIA
TRIP GENERATION SUMMARY
9,000 SF Building Site
Table 1
North Hills Driveway Volumes
Office Use
Total In Out
Table 2
Level of Service Summary
(1990 with Development)
Office Use
LOS E (83)
LOS E (99)
ENGINEERS • SCIENTISTS • PLANNERS • SURVEYORS
10900 NE 8TH STREET, SUITE 300
BELLEVUE, WA 98004
(206) 454-5600
FAX: (206) 454.0220
Retail Use
Total In Out
25 22 3 *40 (28) 20 (14) 20 (14)
18 9 9 *29 (20) 15 (1Q) 14 (10)
27 4 23 43 (30) 22 (15) 22 (15)
225 430 (301) - - - - - -
Estimated
Note: Volumes in parentheses under "Retail Use" represent "pass -by" volumes
based on a 30 percent reduction factor.
Retail Use
LOS E (90)
LOS B (5.31)
LOS E (96)
LOS B (7.14) **
With Signalization
City of Tukwila
PUBLIC WORKS DEPARTMENT
6300 Southcenter Boulevard
Tukwila, Washington 98188
(206) 433 -0179
Ross A. Earnst, P.E. Director
TO: Jack Pace
FROM: Ron Cameron
DATE: September 20, 1991
SUBJECT: North Hills Office Rezone
RC /kjp
File: North Hills Office
MEMORANDUM
SE P 2 199/
North Hills Office rezone will not have a measurable affect on traffic. The
Southcenter Boulevard existing noon and p.m. peak volumes are 2250 and 2650.
The office or retail development will be about 18 or 20 noon and 27 or 30 p.m.
trips respectively.
The difference of less than 5 per hour on over 2000 is imperceptible. The
driveway volumes would have a difference of about 10, still imperceptible and
making no difference in LOS.
Additional evaluation is being prepared to determine the plus and minus of
combining driveways and will be presented next week.
CITY OF TUKWILA
6200 SOUTHCENTER BOULEVARD, TUti (VILA, WASHINGTON 98188 PHONE # (2061433.1800 Gary L. VanDusen, Mayor
STAFF REPORT
TO THE PLANNING COMMISSION
Prepared September 20, 1991
HEARING DATE: September 26, 1991
FILE NUMBER: 91 -1 -R North Hills Office Building
APPLICANT: Leon Grundstein, Gencor Development Inc.
REQUEST: Rezone from P- O: (Professional ; Office) to C -1; (Neighborhood
Retail)
LOCATION: 5900 Southcenter Blvd.
ACREAGE: 1.75 Acres
COMPREHENSIVE
PLAN DESIGNATION: Commercial
ZONING DISTRICT: P -O Professional Office
SEPA
DETERMINATION: MDNS Issued' on October ;1,, >1990 :: =
ATTACHMENTS: A. Vicinity Comprehensive Land Use Map
B. Vicinity Zoning Map
C. Site Plan
Staff Report to the 91 -1 -R: North Hills Office
Planning Commission Page 2
VICINITY /SITE INFORMATION
FINDINGS
Existing Development: There are no existing structures on the property.
Surrounding Land Use: To the west is the Arco service station/Mini -Mart, to the
east is vacant land, to the north above the site is the North Hills Apartments and
to the south is Southcenter Boulevard, I -405 and the Southcenter Mall.
Terrain: Due to previous grading activities, the site contains two "separate level
benches" stepping up the hill with the northern portion of the site containing the
steep slopes and remaining vegetation.
Vegetation: Previous grading activities on the site have stripped the vegetation
except for the northern portions of the site which contains steep slopes with an
average grade of 13.5 percent.
Access: This site has direct access from Southcenter Boulevard. The access is
shared with the North Hills Apartment residence and the AM/PM Mini -Mart.
BACKGROUND
On April 26, .1984, a request for .a.Rezone (file no. 84 -11 -R) for this property was
requested by Don Moody, President of Western Pacific Properties. He requested a
rezone from RMH (High Density Residence) to P-0 (Professional Office). The
Planning Commission recommended approval and the City Council approved the
request.
Since 1984, there has been three different design proposals for this site. The last
project was approved by the Board of. Architectural Review on July 5, 1990 for, an
office building. Attachment C,:reflects the approved site plan.
On June 18, 1990, the City Council approved the applicant's request for a waiver
from the sensitive areas moratorium so that the rezone request could be
processed.
In December 1990; the City Council denied the applicant's request for a rezone
from P -O (Professional Office) to C -1 (Neighborhood Retail) due to the traffic
analysis.
Staff Report to the
Planning Commission ,Page 3
91 -1 -R: North Hills Office
Since December 1990, the applicant has provided additional information
pertaining to the traffic analysis, prepared by Entranco Engineers, Inc..
REZONE CRITERIA
The burden of proof in demonstrating that the change is appropriate lies solely
upon the proponent. Generally, the more dramatic the change, the greater will be
the burden of showing that the proposed change is in conformance, with the
Comprehensive Plan as implemented by the. Zoning Ordinance. .The proponent
must show in a clear and precise manner why the rezone application should be
granted. The 3 rezone criteria contained in the Zoning Code and 3 criteria based
upon case law are shown below in bold, along with applicant and staff discussion
of relevant facts.
TMC 18.84.030 (1) The use change in zoning requested shall be in conformity with the adopted
Comprehensive Land Use Policy Plan, the provisions of this title, and the public interest;
Applicant's Response
"While perhaps not unforeseen, rapid multi- family growth in the immediate area
of our proposal has created a need for adjacent public services."
Staff's Response
The Comprehensive Land Use Plan designates the property as Commercial. The
request is to rezone the property from P -O (Professional Office) to C -1
(Neighborhood Retail.) The Comprehensive Plan states:
Economic Development Issues - Compatability
Policy 1., p.60 Encourage the grouping of uses which will mutually
and economically benefit each other or provide
necessary services.
"Most business land uses, when grouped, complement one another since the
cliental drawn to one will generally frequent others. Advantages are also present
for the grouping of warehouse or industrial areas. This policy is intended to
encourage this planned grouping of complementary uses and thereby maximize the
drawing power or reputation of each grouping. This concept could minimize
business failures and promote prosperity in the business community."
Economic Development Issues - Compatability
Policy 2., Page 60 Allow for the location of new commercial and
industrial areas and the expansion of existing ones
Staff Report to the
Planning Commission
91 -1 -R: North Hills Office
Page 4
when this expansion is compatible with surrounding land use and not detrimental
to the public welfare.
"Just as the City strives to provide land for the location of new business, so should
it provide the opportunity for existing businesses to expand. Due to Tukwila's
location, transportation systems, level land and local services, the City is an
attractive area for the location of commerce and industry. The City has vacant
lands that can accommodate additional location of new business or the relocation
or expansion of local businesses."
Economic Development Issues - Growth
Policy 8., Page 62 Encourage a diversity of business uses to promote maximum
occupancy.
"As the economy fluctuates, various segments of the business community are
helped or hindered more than others. This policy encourages diversity of business
uses to promote maximum occupancy in order to avoid vacant non - productive
building. Vacant buildings slow down the flow of property tax collections and
adversely affect the City and property owner's ability to do financial planning."
The polices encourage the grouping of uses which will mutually and economically
benefit each other or provide necessary services. This area functions as a self
contained commercial node, the rezone request would enlarge a relatively small
regional and neighborhood retail site.
TMC 18.84.030 (2) The use or change in zoning requested in the zoning map or this title for the
establishment of commercial, industrial, or residential use shall be supported by an architectural site plan
showing the proposed development and its relationship to surrounding area as set forth in the application
form;
Applicant's Response
"Please see attached site plan."
Staff's Response
The proposed 9,640 square foot, 1 -story building received Board of Architectural
Review approval with conditions on July 5, 1990. The approved site plan complies
with or exceeds C -1 development standards in the zoning code.
Applicant's Response
Staff's Response
Applicant's Response
Staff's Response
Staff Report to the 91 -1 -R: North Hills Office
Planning Commission Page 5
TMC 18.84.030 (3) When the request is not in agreement with the Comprehensive Land Use Policy Plan,
the applicant shall provide evidence to the City Council's satii/action flunt there is an additional need for
the requested land classification.
"Following per City of Tukwila Comprehensive Land Use Policy Plan;
Goal 1; It would seem in the best interest of public welfare to offer public services
in the form of general retail/commercial easily accessible (within walking distance)
to a multi - family core. Goal 5; In response to extreme topography, we have
recessed our building into the sites hillside. Goal 6; With the viable Dennys and
Arco developments to the west, our proposal follows a local land use pattern that
is balanced in supplying a demand. Goal 8; Please see Goal 6 response above in
commercial development, effective location with efficient user access will
determine whether a business will succeed or fail. Dennys and Arco remain very
viable businesses."
The request is in conformance with the Comprehensive Land Use Policy Plan
Map designation of Commercial.
(4) Significant changes have occurred in the character, conditions or surrounding neighborhood that
justify or otherwise substantiate the proposed rezone.
"Rapid multi - family growth in the immediate region has created a need for
adjacent public services, in the interest of viable business practice which in turn
will serve the public welfare. We are proposing an attractive, well scaled 9,640
square foot commercial structure."
In 1986, then adjacent site did receive a Comprehensive Plan Map change from
High Density Residential to Office and a rezone from R -4 (Low Apartments) to
PO (Professional Office). The site of the rezone (File numbers 86 -65 -CPA and
86 -66 -R: Kato) fronts on 62nd Avenue South, is located above the subject site and
remains developed with a single family home.
The road classification for Southcenter Boulevard from the "S" line bridge to
Interurban Avenue S. has changed form collector arterial to principal arterial.
Staff's Response
Applicant's Response
Staff's Response
91 -1 -R: North Hills Office
Staff Report to the
Planning Commission Page 6
(5) The proposed rezone is in the best interest of the public health, safety, and welfare as compared to
the hardship, such as diminution of property value, imposed on the individual property owner.
Applicant's Response
"Please see #1 above. Our proposal serves the public welfare in answering a need.
Office demand has leveled off, therefore, the only hardship in this case would be
returning to a larger office structure."
The request for C -1 from P -O is consistent with the Comprehensive Land Use
Policy Plan Map designation. The C -1 (Neighborhood Retail) would be an
extension of the existing adjacent zoning. The subject site is also compatible
topographically and visually with the adjacent commercial development.
As stated by Ron Carmen, City Engineer, "North Hills Office rezone will not have
a measurable affect on traffic. The Southcenter Boulevard existing noon and pm
peak volumes are 2250 and 2650. The office or retail development will have
about 18 or 20 noon and 27 or 30 pm trips respectively. The difference of less
than 5 per hour on over 2000 is imperceptible. The driveway volumes would have
a difference of about 10, still imperceptible and making no difference in LOS.
Additional evaluation is being prepared to determine the plus and minus of
combining driveways and will be presented next week."
(6) The unimproved subject property is unsuitable for the purpose for which it has been zoned, considered
in the context of the length of time the property has remained unimproved and land development in the
surrounding area.
"Please see #1 above Re: Land Development, and item #2 above Re: Office Use.
Additionally, this particular site is small and steep, much better suited to
commercial use requiring glazing on the street side only, versus office which
typically requires glazing on all sides."
The topography of this parcel separates it from the adjacent office and residential
areas. The commercial business node along Southcenter Boulevard is adjacent to
the subject site which shares the same driveway or access to Arco -Mini Mart.
Ey hoed P$oR. +L 474
CONCLUSIONS
Staff conclusions are summarized below under the six criteria.
nteria 2: �
riteria 3 " }
91 -1 -R: North Hills Office
Staff Report to the
Planning Commission Page 7
This parcel has been zoned P -O (Professional Office) since 1984.
All sites within the P -O districts along Southcenter Boulevard are fully developed
with the exception of the subject site and the 1986 Kato rezone site.
The rezone request conforms with the adopted Comprehensive Land Use Policy Plan
Map which, designates the site as Commercial.
The request is in conformance with Policy #1 (page. 60) of the Comprehensive Land
Use Policy Plan since the rezone will be an expansion of the neighboring commercial
zoning district. The new commercial site will provide economic opportunities that could
mutually benefit the existing business and the new business will benefit from the
neighboring ones.
This request also complies with Policy #2 (page 60) of the Comprehensive Land Use
Policy Plan because the expansion of the existing commercial area is compatible with the
surrounding land uses and will not be considered detrimental to the public welfare.
The request is in conformance with the Comprehensive Land Use Policy #8 (page 62)
the C -1 zone will allow a greater diversity of businesses on the site either commercial or
office because of Tukwila's cascade zoning. This will promote maximum occupancy of
the new building , the ability for expansion of new businesses, and the expansion of
relatively small commercial area.
The applicant has provided a site ; plan, approved . by the . Board of Architectural Review
on July 5, 1990. The approved site plan will comply with C -1 zoning standards.
The request is in conformance with the Comprehensive Land; Use Policy Plan Map
designation of . Commercial.
Staff Report to the 91-1-R: North Hills Office
Planning Commission Page 8
• This parcel had a Co Mprehensive-Plan Map change from7High Density Residential to
Office and a Rezone from R-4'to hi-1986. Also Southcenter Boulevard has changed
from :a collector arterial to a principal aiterial.
ough the Environmental review process there were no significant impacts identified. 1,
The City Engineer noted that the rezone will not have a measurable. affect on traffic.:,
Given the Comprehensive Plan designation of this parcel, the rezone would not create a
spot zone. It will be an extension of the existing commercial area.
The parcel is physically separated by the steep slopes from the residential development
,tg,thenorth and office; development to the east. The rezone would provide a logical
„.,
expansion of the existing commercial develop along Southcenter,Blvd. E mo pi 411 dAsf
hInd5 74/4
P 1 : 0 6 65 i4 te.27 it4 /e1N0, 40. /ti r
RECOMMENDATIONS , f , rne. 44 ez .
, /rie•etteti.
The Planning Staff recommends that the Planning Commission adopt the findings (4z
Conclusions of the ,staff report and recommend approval of the,request-from PO.to
II •
MA); ,11 1,0));
111 tiaai
(UP ;; ; ) 4 111 40
•
•••
• • • ''•
% • • • • • • • • • •
'
710:-.5
1 11
a
r61. '‘
1
t t •
f •....•••••••
tr.v.v.r.r.11 1
3••••••••••••4
7=7
" • 71•70
• ;
•••••••••••••••
r • • • • • • • • • • •"" t
IA,==.7...14,
• •••••••••••••••« , ,
II
1 ...•.1.4••••■■•••••■■ ,
••••••••...•••••• : :
•
• ". •„ 1 -
••••• .;
\\
••'"":
k
FSITA
. • • 51 \
$ • • •• • • • •4 ti
• • a • 111
• • • • • •;
,
It'. • • 1.61.(i \
Op • • 46 , 4 !„ .u. • L- 1 t
i
•• 4 1 s
F.;•.
'
F. • • a • 8 4•
..1 0
... iee•TA ' . - T
\
' . . • V•
o
\
, i '.m a es•e ' is zt's 11
- '.,.,
8 - • • ai. .,
• • • • • •- • •
• • • • •:-• / • it
•
• • • • • •
••••,.., • RAI • •
... .
•
........ •
-,•••••%. •
...... 7. ...... • • • •'.• • •
"••
••••••••wr
s•••°
\\
\s‘ •
t tLL
.... ..2 ... :
.. •
. .. g' 7.71,A
. .
\ \,.
' \i ", ...-.........• ..... ..
ss.. . ..
sN. ••,?-- .. .., ...
JECT SIT
(4(ft
ki
1 g0:.
)... •
..1.4,:; ...
...,, A .r.i. •
-...•.
.. •• • ......
•...•,„...
''''!'li:
•....--;,...•...--...
,. .....-.,.....,
41 I•
.....
•-... .......,. •
lt,.. \...,
---,,,, ..fl •
L •• • i
4:
6 0 \ !
•4.. '...!
,
4.* •■••••••■•
' ' •-• .. -;,
- . ..
..:
.. ,- " i " i : iiLiir= im„ iri .
••••••••• . .
/-:•••••en•••• • 4-- ..-.
i • • • •••••••••••••••• Op . . -,.•• .... .,, ..: ,.';;./•
;"••••••••••••••••••••aVesa•••40:••• 811:•••••
''a • • • • • •••••••••.%•aseemsuaaassa.ves.••••••••11
•.:.± .al-V•8•68••••M• • • • I s a n a le a s a • o • a • a • u • a y a s a s a it a s s a a a a p
i s • • Me . • 0 • me
iaaaa8eOlielalealleollaumais es e a
imeim • • pp a
i•sus.VW••••••••••• ••••S
••aa•••••••••••te• • • • • il
,, • • • • • • e a-. ..... s
• s...v....i
f ............. • eiteems•••••••••• •sal, ..•
... c 1 • • • • • • • se........e.....• •
••••••••••• ig s
!` 1 s ............... • • • • • • • • •••••••••esp
•' 7 • a•-••••••-••••••••
'• ;••••••••••••••••••••••••••••1
;•••••••••••••••••••••••••••••
as s•s••••••••••••• ••••••••••p
: ' I • • • • • ••••
0 • • ••••••••••••••• • •
- ••••••••• ••••••••••••••••••••
'.:.• ••••••••••••••••••••••••••••••
• 1 ;„•asseasaaaanaanameawayasamaseassaaanaremeameasaaaaap
7 i i Isms • • • • • • • •_•_•
• • • • • miumpenew
.-.1 1••••••••••••••••••••••••••aar..••1.
mw••••••••••••••••••••••••••••••••°........ •• . •••• •1
. . ..
6 14 AVC
*:c
Gc:0- CET.
r.
1•71:1.. •
--4
IS
AT TA
• Goa.V.so-Alb.L.V
7
410"" _ 49 , 644 ,
: red •qpit
January 30, 1991
Mr. Ron Cameron
City Engineer
City of Tukwila
6300 Southcenter Boulevard, Suite 101
Tukwila, Washington 98188
Re: Trip Generation Comparison for Retail Land Use
Versus Office Land Use
Entranco Project No. 90809 -06
Dear Ron:
ENTRANCO ENGINEERS, INC.
LAKE WASHINGTON PARK BUILDING (206) 827 -1300
5808 LAKE WASHINGTON BOULEVARD N.E., KIRKLAND, WA 98033
This letter outlines the trip generation comparison conducted for the previously
proposed 9,000 square foot North Hills Office Building in Tukwila, Washington. The site
is located on the north side of Southcenter Boulevard west of the 61st Avenue South
Bridge and adjacent to the existing Arco AM /PM Mini Mart site.
A traffic impact analysis was previously conducted for the proposed North Hills Office
Building in March 1990 by Entranco Engineers, Inc. The results of the analysis showed
that the proposed site under a "general office" land use scenario would generate 225
vehicle trips per day with 27 occurring during the p.m. peak hour.
In comparison, a trip generation analysis conducted for the same proposed site under
a "general retail" land use scenario would generate a gross total of 430 (estimated via
10 times the peak rate, due to lack of a daily vehicle trip rate) vehicle trips per day with
43 occurring during the p.m. peak hour. However, under a retail land use scenario, the
trip generation to the site includes "new" trips as well as "passby" trips. Assuming a
passby reduction factor of 30 percent, then the actual number of new "net" trips
generated to the site is 301 vehicle trips per day with 30 occurring during the p.m. peak
hour. A conservative 30 percent passby factor was assumed to produce a worst case
value since the range of passby factors, according to studies conducted and published
by the Institute of Transportation Engineers (ITE), have been found to be 30 to 60
percent, depending on the size of the facility. These studies have shown that the
smaller the facility (e.g., retail strip mall compared to a regional shopping center,) the
higher the passby factor.
(Reference: "A Methodology for Consideration of Pass -By Trips in Traffic Impact
Analyses for Shopping Centers" , Steven A. Smith, ITE Journal, August 1986.)
Since the net number of retail trips generated during the p.m. peak hour (30) is only
three trips greater than that generated by the originally proposed office use (27), then
no significant additional impacts are expected with the conversion of the site from office
to retail use.
EVERETT OFFICE 516 SEATTLE -FIRST NATIONAL BANK BUILDING (206) 258 -6202
1602 HEWITT AVENUE, EVERETT. WA 98201
V •
Mr. Ron Cameron
January 30, 1991
Page Two
We trust that this additional analyses will assist you and Gencor Development in
gaining approval for the land use conversion proposal. Please call if you have any
questions or concerns regarding the information presented in this document.
Sincerely,
ENTRANCO ENGINEERS, INC.
' 0111111
Project Manage
Sherman D. Go
SDG:ckm
March 28, 1990
Mr. Ron Cameron
City Engineer
City of Tukwila
6300 Southcenter Boulevard, Suite 101
Tukwila, Washington 98188
Re: Traffic Impact Study for the Proposed North Hills Office
Building in Tukwila, Washington
Entranco Project No. 90809 -06
Dear Ron: .
This letter outlines the traffic impact analysis performed for the North Hills Office Build-
ing in Tukwila, Washington. The proposed site is located on the north side of South -
center Boulevard west of the 61st Avenue South Bridge and adjacent to the existing
Arco AM /PM Mini Mart site. The proposed development will consist of 9,000 square
feet of general office space. Two access driveways are planned to ingress and egress
the site. One driveway will access the site from Southcenter Boulevard and the other
driveway will access the existing North Hills Driveway.
EXISTING CONDITIONS
ENTRANCO ENGINEERS, INC.
LAKE WASHINGTON PARK BUILO f2061 827.1300
5836 LAKE WASHINGTON BOULEVARD N.E.. KIRKLAND. WA 98033
Southcenter Boulevard will provide the primary access route to the proposed site. It is
currently a five lane east -west minor arterial with two lanes in each direction and a cen-
ter left turn lane. The speed limit is currently signed for 30 mph.
The existing North Hills Driveway serves the 54 unit North Hills Apartments complex
just north of the proposed office building site and the Arco AM/PM Mini Mart The Arco
facility operates with two other existing driveways along with the North Hills Driveway. A
noon peak (12:00 = 1:00 p.m.) and p.m. peak (4:00 - 5:00 p.m.) hour turn movement
count was conducted for the North Hills and Arco driveways on March 19th and 20th.
1990 by Entranco Engineers. The City of Tukwila Engineering staff provided the exist-
ing traffic volume data for Southcenter Boulevard. Figure 1 shows the 1990 existing
traffic volumes at the Southcenter Boulevard/North Hills Driveway intersection.
Traffic flow operations were also observed during the noon and p.m. peak hours. The
observations showed no significant operational problems except for the westbound
queue from the Macadam Road / Southcenter Boulevard intersection which occasionally
extends from the intersection back beyond the North Hills Driveway. This queue was
observed during the noon and p.m. peak period, although the noon peak queue did not
occur with the frequency or the length of the p.m. peak. No queues were observed in
the center left turn lane during either peak period.
Mr. Ron Cameron
March 28, 1990
Page Two
TRAFFIC FORECASTS
The intersections of Southcenter Boulevard /61st Avenue South and Southcenter Boule-
vard /Macadam Road are presently controlled by signalization. With a traffic signal lo-
cated on either side of the North Hills Driveway, gaps are created on Southcenter Bou-
levard which allow the outbound traffic from Arco or the North Hills Apartment to enter
the traffic stream. The gap opportunities on Southcenter Boulevard, however, do not al-
ways occur simultaneously for the eastbound and westbound direction, therefore, vehi-
cles currently attempting a left turn eastbound from the Arco or North Hills driveways
used the center left turn lane as a refuge before merging into the eastbound traffic.
This behavior is not uncommon for driveways which access a five lane urban arterial
facility.
Table 1 summarizes the total number of trips which the proposed office building will
generate during the noon and p.m. peak hour. These p.m. peak hour trip generation
values are based on the total gross square feet of floor area and the rates published in
the Institute of Transportation Engineers' "Trip Generation Manual", 4th Edition, Sep-
tember 1987. The noon peak hour generation values were based on a 12 -hour (6:00
a.m. to 6:00 p.m.) driveway volume count at an existing office park. The proportion of
noon peak trips to p.m. peak trips of the existing office park was applied to the North
Hills Office generation to determine the noon peak project volumes. Figure 2 shows
the project - generated traffic volumes for the noon and p.m. peak hours.
General Office (ITE Code 710)
(9.000 sq. ft.)
P.M. Peak Hour
Noon Peak Hour
Table 1
Trip Generation Summary
Daily Enter Exit Total
•
225 4 23 27
9 9 18
The proposed North Hills Office Building will generate a total of 225 average daily vehi-
cle trips with 27 trips occurring during the p.m. peak hour and 18 trips during the noon
peak hour.
Trip distribution of the project generated trips were based on the existing turn move-
ment volume counts conducted by Entranco for the Arco and North Hills Apartments
driveways, and the reported trip distribution in the North f -1111s Apartments Traffic Study
performed by Entranco in December 1987. The project generated trips were distribut-
ed evenly (eastbound and westbound) on Southcenter Boulevard for the noon peak
generated trips and approximately 60 percent westbound and 40 percent eastbound for
the p.m. peak generated trips. Although the proposed project site has two planned ac-
cess driveways, all of the project generated trips for either peak hour were assigned to
the shared Arco and apartments driveway as a worst case condition since the planned
Southcenter Boulevard driveway was designated for right -in /right -out access only. Fig-
ure 3 shows the 1990 total traffic volumes with project generated traffic at the access
driveway and study intersection.
Mr. Ron Cameron
March 28, 1990
Page Three
TRAFFIC IMPACT ANALYSIS
Table 2
Level of Service Summary
A level of service (LOS) analysis was conducted for the intersection of Southcenter
Boulevard /North Hills Driveway during the noon and p.m. peak hours under existing and
future conditions. All LOS calculations followed the methodology outlined in the 1985
"Highway Capacity Manual". Table 2 summarizes the results of the LOS analysis.
Peak Period 1990 Existina 1990 With Project
Reserve Reserve
Capacity Capacity
Unsianalized LOS (veh. /hr.) LOS - (veh. /hr.)
Noon Peak E 71 E 83
P.M. Peak D 102 E 99
Delay Delay
Sianalized LOS (sec. /veh.) LOS (sec. /veh.)
Noon Peak N/A N/A B 5.27
P.M. Peak N/A N/A B 7.02
The results of the LOS analysis shows that the intersection currently operates at LOS E
and LOS D for the noon and p.m. peak hours, respectively. With the addition of the
North Hills Office Building generated traffic, the LOS analysis indicates that the noon
peak hour LOS will remain at LOS E. The analysis for the p.m. peak hour indicates that
the LOS will deteriorate from a LOS D to LOS E with the project generated traffic. The
LOS analysis for an unsignalized intersection, however, does not take into account the
gaps created by the adjacent traffic signals on Southcenter Boulevard at Macadam
Road and 61st Avenue South. The LOS was also analyzed assuming the intersection
would be signalized. A LOS B was obtained for both the noon and p.m. peak periods.
As a result of the LOS E obtained for the p.m. peak hour with project volumes, a signal
warrant analysis was conducted for the intersection. Signal warrants I and II of the
"Manual of Uniform Traffic Control Devices" (MUTCD) were analyzed for the intersec-
tion. Since 24 -hour counts were not available for all approaches, the signal warrant
analysis used the projected average daily volumes as the criteria for the analysis. The
volume requirements for average daily traffic volumes were interpolated from the Wash-
ington State Design Manual and the values given in the MUTCD. The analysis indicat-
ed that the volume requirements for the major road would be met for both warrants,
however, the projected volumes on the minor road (North Hills Driveway) with project
generated traffic did not meet the volume requirements for either warrant. Therefore,
signalization of the Southcenter Boulevard /North Hills Driveway intersection is not war-
ranted nor recommended at this time.
Mr. Ron Cameron
March 28, 1990
Page Four
A queue analysis was also performed for the Southcenter Boulevard /North Hills Drive-
way intersection under stop sign control and signalization. The analysis was conduct-
ed for both the noon and p.m. peak hours using the projected future volumes with the
proposed project. The analysis of the intersection under stop sign control assumed a
"wait interval" of two minutes for the critical turn movements. The analysis of the inter-
section under signalization assumes a cycle length of 60 seconds with green time allo-
cated proportionally to the approach volumes. Table 3 summarizes the results of the
queue analysis.
Table 3
Queue Analysis Summary
Queue Length Queue Length
Critical Movement Peak Period Unsionalized (ft.) Sionalized (ft.)
Eastbound Left Turn Noon 44 22
Eastbound Left Turn P.M. 44 22
Southbound Left Turn Noon 66 44
Southbound Left Turn P.M. 66 44
The results of the queue analysis project that the eastbound left turn movement vol-
umes from Southcenter Boulevard will create a queue of 44 feet for both the noon and
p.m. peak hours under stop sign control. The southbound left turn movement volumes
from the North Hills Driveway will create a queue length of 66 feet under stop sign con-
trol during both the noon and p.m. peak hours. The queue analysis was also conduct-
ed for the intersection assuming signalization. A projected queue of 22 feet will be ex-
perienced for the eastbound left turn movement from Southcenter Boulevard during
both the noon and p.m. peak hours. The southbound left turn movement from the North
Hills Driveway will experience a projected queue of 44 feet for both peak periods.
The planned access driveway from the proposed site at the North Hills Driveway is lo-
cated 75 feet north of the intersection, therefore, the 66 foot queue created by the
southbound left turn volumes will not interfere with the operations at the planned drive-
way under stop sign control. The 44 foot queue projected for the eastbound left turn
movement from Southcenter Boulevard will occasionally block left turning vehicles from
Arco's East Driveway, however, the recent driveway counts conducted by Entranco for
the Arco driveways indicate that 60 percent of Arco's customers use the Arco West
Driveway, therefore impacts to the Arco East Driveway will be minimal.
The Southcenter Boulevard extension to Grady Way will increase traffic on Southcenter
Boulevard approximately 4 percent according to the "Southcenter. Boulevard Environ-
mental Assessment Study" conducted by Entranco Engineers, February 1983. This
growth will occur with or without the proposed North Hills Office Building. Since the trip
generation from the project is minimal, the Southcenter Boulevard extension will have
negligible influence on the distribution of project- generated traffic.
Mr. Ron Cameron
March 28, 1990
Page Five
SUMMARY
The proposed North Hills Office Building will generate a total of 225 average daily vehi-
cle trips with 18 and 27 trips occurring during the noon and p.m. peak hours, respec-
tively.
A level of service analysis was conducted for the Southcenter Boulevard /North Hills
Driveway intersection during the noon and p.m. peak hours with the project generated
volumes. A LOS E was obtained for both peak periods with the additional volumes.
A signal warrant analysis was performed for both peak periods to determine if a traffic
signal should be installed to improve the operations of the intersection. Signal warrants
l and II were evaluated for the future intersection volumes. The analysis showed that
neither warrant would be met.
The queue analysis performed for the eastbound left turn movement from Southcenter
Boulevard and the southbound left turn movement from the North Hills Driveway
showed that these critical movements would experience a queue of 44 feet and 66 feet,
respectively. These projected queue lengths will have negligible impacts to the adja-
cent driveway operations.
Based on the above analysis results, we suggest the following recommendations to en-
hance the safety and operational efficiency of the intersection and adjacent driveways:
• Paint a crosswalk for the North leg of the Southcenter Boulevard/North Hills
Driveway intersection.
• Repaint the existing striping on Southcenter Boulevard to clearly identify the cen-
ter left turn lane.
• Monitor the Southcenter Boulevard/North Hills Driveway intersection with future
development to determine the implementation of a traffic signal.
We trust that this traffic analysis for the North Hills Office Building development will as-
sist you and Gencor Development. Inc. in gaining approval for their proposed project.
If you have any questions or concerns regarding the information in this document,
please do not hesitate to call.
Sincerely,
ENTRANCO ENGINEERS, INC.
Sherman D. Goong
Project Engineer
Attachments:
Figure 1 - 1990 Existing Traffic Volumes
Figure 2 - Project Generated Volumes
Figure 3 - 1990 Total Traffic Volumes with North Hills Office Bldg.
.-5Z 1 (»i-z1) (2 WZ 1 )
r s- coo .s,---9szi
1
Itk ,rrit 1
I kall - 1
I W.1 /SIN A Ni .1.. it I
ay- LI:epsiNN-INlyi I
0 .,, 61 ,/ 1 Nitl.,,
a.u W-/0
'YkZ,k
( Y?
C
al) S. a7 LijQ C �Z �
S'T71 H HJ -?loft/
E-- (9
(
>,
�•�d -It4
V44 /wbd I -�.r rwl�a2t
Q I ANs'ij
4sz1
Qv w I I
w.a /w►d �.c rwrcait
b � I 07vi AN t tzsca
a „s a��o
S-n i r Ms-VoN
k
l
33
0
> >
e g
2 L
x
x
January 30, 1991
e
Mr. Ron Cameron
City Engineer
City of Tukwila
6300 Southcenter Boulevard, Suite 101
Tukwila, Washington 98188
Re: Trip Generation Comparison for Retail Land Use
Versus Office Land Use
Entranco Project No. 90809 -06
Dear Ron:
ENTRANCO ENGINEERS, INC.
LAKE WASHINGTON PARK BUILDING 12061 827.1300
5808 LAKE WASHINGTON BOULEVARD N.E.. KIRKLAND. WA 98033
This letter outlines the trip generation comparison conducted for the previously
proposed 9,000 square foot North Hills Office Building in Tukwila, Washington. The site
is located on the north side of Southcenter Boulevard west of the 61st Avenue South
Bridge and adjacent to the existing Arco AMIPM Mini Mart site.
A traffic impact analysis was previously conducted for the proposed North Hills Office
Building in March 1990 by Entranco Engineers, Inc. The results of the analysis showed
that the proposed site under a `general office" land use scenario would generate 225
vehicle trips per day with 27 occurring during the p.m. peak hour.
In comparison, a trip generation analysis conducted for the same proposed site under
a "general retail" land use scenario would generate a gross total of 430 (estimated via
10 times the peak rate, due to lack of a daily vehicle trip rate) vehicle trips per day with
43 occurring during the p.m. peak hour. However, under a retail land use scenario, the
trip generation to the site includes new trips as well as "passby" trips. Assuming a
passby reduction factor of 30 percent, then the actual number of new net trips
generated to the site is 301 vehicle trips per day with 30 occurring during the p.m. peak
hour. A conservative 30 percent passby factor was assumed to produce a worst case
value since the range of passby factors, according to studies conducted and publishea
by the institute of Transportation Engineers (ITE), have been found to be 30 to 60
percent, depending on the size of the facility. These studies have shown that the
smaller the facility (e.g.,' retail strip mall compared to a regional shopping center,) the
higher the passby factor.
(Reference: "A Methodology for Consideration of Pass -By Trips in Traffic Impact
Analyses for Shopping Centers ". Steven A. Smith. ITE Journal. August 1986.)
Since the net number of retail trips generated during the p.m. peak hour (30) is only
three trips greater than that generated by the originally proposed office use (27), then
no significant additional impacts are expected with the conversion of the site from office
to retail use.
f'r `••F81: ..u:N e,a;.ONA: RANd rU4 ^■N:. •;.431: ". r:::
Evitsi ,, t,4 .-C +�•
Mr. Ron Cameron
January 30, 1991
Page Two
Sherman D. Goong
Project Manager
SDG :ckm
ENTRANCO ENGINEERS, INC.
We trust that this additional analyses will assist you and Gencor Development in
gaining approval for the land use conversion proposal. Please call if you have any
questions or concerns regarding the information presented in this document.
Sincerely,
,/ •
4... ..... 4
-
NI 014 4,4)))4
4(4 (laa4a((((
)4 4. 44/• 41/40))Mni.;
a . 1'((4 tagro((0((((((a
:V.:SA:LI 1
F.V.V4 \
gal \
1 1 I l i \ k f t l ,
%.•••••••.% i t '
1 \ .,
....••••••••
z b0 .7: 0•1 = ••••••••••
11
"
F 16:€0:• it t 1 t I • • ..'.
:A::: .. . • • ..... •1.1, •• • : ••"...«.: : 1 k . I t
••••••••••••••.“ i • . . • ,
VA .7 : .......:A 1 '. %:•.-
•••••••••14=1 ' • , i k k'
V.V.V.V.V..• ••••.. • •
......... , : ; ‘ \ S
,..••.V.AVAVAVA .. : t
••• ••••••■••
....... '...'.• 7•04 7 '', \ .
' • 1 . \ d 1\ ‘
a 1 } ' •
••••• 1 s
T•74 1 ‘ ‘ \ \
I:: ••:::. At
3•:
K \ \ 1 \
r- ••••••••
pr9....., \ \
:•••.: 1.
„..
• • • • • \
• •—, 1 \ 1
\ \ \\ '
• ''' 4. \\ • . , ''''..:
:: iii i i• ° Mt ,
• • • ft) ‘ 1 %
m • III;. '
1 1 1 : : ::.: :1 eliene % \
., .,........ • • -,--
4 -a_..,. A l ' 4 AV\ '‘.^:' '''.
• • •,, 1
‘••••\ -‘s•
\ ,,, St „; - --------- ' -4 .\
. ,
V ...
--2,P.P..!:
7P" 'a . .‘f a fill ...il'•"•"!„,
p.,...,■c-----:-.T.'-- i 1
.
if ?• ;1..
.l I -sii z :
• . ..I f f • • a • a •• •a,- !,- • • •1
; I , t i •.•. 1
\ \ •‘‘.\\ \\'', • - • • -, N,
..... ..
8 el 0
• •
.. :,,,...,.,•, , l
\ \ s ,,-,-,...,..,
: • — :\
A . .‘ .v--.":.■.''. .' 4811 :
• i ;,. ■e e • • 11.11P t... '''., t V \ ::;•„ In •
, :;1 0 • e IDAlo ••• II,
F- ' 4 •
' ' • • • • • • • • • •'•
t A • • • • • •11 ▪ 4.84 4
't ' la WI!
's.. -‘r
<
•
•
•
.RQ JET Si
•
.....
• • •-, , „ „.
•
•
• •
• ‘s
• • "
\II: _____, 7 - . ,1j . :,/..,/,,/ 4:••••••• -
1 ,7 • • , ; .' • / le s a li e ll w %:■ . . ....... ,, .- ,
-141,:si '' a 11. • miLa
' "'s••••••aastasses. , .
ei
;1 . ,. I • • • • • • • • • • • •
+ i i :: /1■11•8•••••••%6•8•618.85 • • II • • • • & •••••s••••••••• Ils.
• Mail MISIBIS• •
1 • , i. ii:•:•:••••:••••••••••:11:•:•••••••••••••:•:••••:•:••■•••••••%•••:11.,
t!
:.,• , t •• Il •• • •.• ••••••••••••••• ••• • • ••••• • • • • • 8
; •a•••••••••••••• • • • • • • ••• ••••••• • •613811.111••••• 1
!••••••111,11•••• ••••••••••••••••••
•Isatitia••••••••••••it••11 WIRE ti. I
. • • a • • • • IF • II•11 II •••••••••••Vea•011.0.15.01Was.i
t
1 1 , : • : 1 . .:i i - f imeagassesswesaviessasessasesows...... 4 . a • s o:
t..t,
‘
Il li i ':,; issmeassymeessommansmosemenammeammusasommesessimafe
\
It i. ; c I ::: i • • • • • it se• it- s e
Y 1 1 .,7 1. i i : ....t ;It EV atosta••••••••••••••• EP
11 t iii ::•.1 i'mas'esueeemanauXemammenueeseeeltneesseemmel.
, I I V: 1 , ': t (.....sswelysta. • sents.......vmseeseueveves. .1
'‘ ' • t.' • ' - ' • • • •••••••••mmunis•• ••••■sas
•,,, , 1 . ! ! ! : - . f 1.0.888.1■1611.%11ealleeesVaVVVV:eete.11.1%,%Viii
on weaselling. ••••••••■••••....•.•as„.....J
N
-I •
:st.)
l ►. y
Of /was
•••••1
•1 4 . . •• .I
/ 4
1 . t ; G
1 + . .{ SP e,. ` � tA
; ,�� '� � n t % Oi l.?, 0� V
J
r•+ r•• • wl..
e ND }% AVC
"NORTH HILLS OFFICE"
10/16/91
AN ORDINANCE OF THE CITY OF TUKWILA, WASHINGTON RELATING TO
ZONING CLASSIFICATION FOR "NORTH HILLS OFFICE" AMENDING
TUKWILA MUNICIPAL CODE CHAPTER 18.08.030 (AMENDING CERTAIN
PROVISIONS OF ORDINANCE NO. 1247), and
WHEREAS, the proposed zoning complies with the Tukwila
Comprehensive Plan designation of commercial; and
WHEREAS, the City Council adopted the Findings and Conclusions
contained in the Staff Report, dated September 26, 1991, for approval
of a zoning classification of C -1 (Neighborhood Retail); and
WHEREAS, the City Council reviewed and approved a zoning
classification of C -i (Neighborhood Retail) on October 21, 1991; and
WHEREAS, the amendments set forth below are necessary to correct
the Tukwila Zoning Map as originally adopted in Ordinance No. 1247,
1982); NOW, THEREFORE,
THE CITY COUNCIL OF THE CITY OF TUKWILA, WASHINGTON DO ORDAIN AS
FOLLOWS:
Section 1. Zoning Map Amendment. The Tukwila Zoning Map
originally adopted in Ordinance No. 1247 is hereby amended to
include the area known as North Hills Office, bounded at 5900
Southcenter Boulevard, except that property currently
containing the North Hills Apartments (as shown on Attachment
A). A zoning classification of C -1 (Neighborhood Retial)
hereby adopted for the aforementioned North Hills Office
area.
Section 2. Severability. If any section, sentence, clause
or phrase of this ordinance should be held to be invalid or
unconstitutional by a court of competent jurisdiction, such
invalidity or unconstitutionality shall not affect the
validity or constitutionality of any other section, sentence,
clause or phrase of this ordinance.
Section 3. Effective Date. This ordinance shall take effect
and be in full force five (5) days after publication of the
attached summary which is hereby approved.
PASSED BY THE CITY COUNCIL OF THE CITY OF TUKWILA, WASHINGTON, at
a regular meeting thereof this day of , 1991.
ATTEST /AUTHENTICATED: APPROVED AS TO FORM:
Jane Cantu, City Clerk Office of the City Attorney
Filed with the City Clerk:
Passed by the City Council:
Ordinance No.
APPROVED:
Mayor Gary L. VanDusen
Comprehensive Plan Amendment Application
Item 9 Responses:
The City of Tukwila Comprehensive Land Use Policy Plan, Page
12:
GOAL 1: It would seem in the best interest of public
welfare to offer public services in the form of general
retail /commercial buildings easily accessible(within
walking distance) to a multi - family core.
GOAL 5: in response to extreme topography, we have recessed
our building into the site's hillside.
GOAL 6: with the viable DENNY'S and ARCO developments to
the west, our proposal follows a local land use pattern that
is balanced in supply and demand.
GOAL 8: Please see GOAL 6 response. In commercial
development, an effective location with efficient user
access will determine the success or failure of a project.
The proposed use of C -1, or retail, makes access to retail
services in the area more convenient for residents of the
apartments and condominiums on the North Hill. According to
traffic studies, there is also no apparent increase in
traffic as a result in the zone change.
s (CI
(
- 3 Ui`:MLA
PLANNING DFPT.
NOT PUDLISHED. ALL RICH'S RESERVED TNt AROVt DRA.INCS
AND SPECIFICATIONS. AND IDEAS. OESICNS *NO ARRAMCIMENTS
REPRESENTED THEREBY ARE AND SHALL REMAIN THE PROPIRTT
Of TNt ARCHITECT MO PANT THEREOF SMALL DE REPRODUCED,
COMO. ADAPTED. DISCLOSED OR DISTRIBUTED TO OTHERS.
SOLO. PuSLISHID, ON OTHIRRISE USIO WITHOUT THE PRIOR
RRITTEN CONSENT Of AND APPROPRIATE COMPENSATION TO THE
ARCHITECT. VISUAL CONTACT KITH THE ASSOVE DRARINCS OR
SPECIFICATIONS SHALL CONSTITUTE CONCLUSIVE EVIDENCE Of
ACCEPTANCE OF THESE RESTRICTIONS.
4423
REGISTERED
ARCHITECT
EDI LINARDIC
STATE OF WASHINGTON
consultants :
„
PA.
o architects
linardic design group . architects
1836 westlake ave.n. suite 204
seattle, wa 98109 (206)283
project title
NT- RILL_
4:01 E.N000L ItilGp
is
.I Ii •1 i � j �.iS n'I'-1'f`ri
1' )
• ;'' OF "1 .1; kit, ' ' -! •
' —c
N
3/B' CWB ON 3 sir
MU MUDS • 2C CC
FILL HEIGHT
toe rl
� I ROOM
loo
OFFICE
IOT
1 -1EHANF MALLS AS BE00
i
r — I II
ll L__ _J 11
OFFICE
•
FLOOR PLAN
MDT uHS 11 [.,
s DT UHT.
i
I r
,! L - J . 11
102
OFFICE
4rw U. .
S- .1
4T —P
. 103
OFFICE
u r -
i II
1lLl
z5 -
'104
33' -
OFFICE
7.
105
OFFICE
1•�
b
b
b
b
, :;:�c,•;r.:.�L_:.>�?Gr - ti'ti:' � ?�Z�c. .�' , t :,•., `�:� . � , yx4-4 4,, �.s.}
SOUTH ELEVATION
L
NORTH ELEVAI
•
rceagryaera
cor.eso . cox.
W to.
fa 6t
.
00 iouthcenter Boulevard, Tukwila, WA 98188
DEPARTMENT OF COMMUNITY DEVELOP ENT U ? 1001 Telephone: (206) 431 -3680
CITY OF TUKWILA
1. BRIEFLY DESCRIBE YOUR PROPOSAL: 0.e . S
pvo +D
2. PROJECT LOCATION: (Give street address or, if vacant, indicate lot(s), block, and sub-
division; or tax lot number, access street, and nearest intersection)
.5 SoulLce4 e.N V hid
Quarter: r ) 3 Section: € 3 Township: y Range:
3. APPLICANT:* Name:
Address:
hon
Signature. ! P � l""bate: 7h 01 9,
* The applicant is the person whom the staff will contact regarding the application, and
to whom all notices and reports shall be sent, unless otherwise stipulated by applicant.
4. PROPERTY Name:
OWNER
( COMPREHENSIVE LAN AMENDMENT
j I
CoNlYMn✓'G.\ .. I
4 -or G ruen
(This information may be found on your tax statement)
AFFIDAVIT OF OWNERSHIP
G'encor 1,rc_
Address: 75o ( s+ tP . o a
I L
Phone: 50 - -3 ? o.)
I/ WE,[signature(s)] em, ,a„
swear that I /we are the owner(s) or contract purchaser(s) of the property involved
in this application and that the foregoing statements and answers contained in this
application are true and correct to the
best of my /our knowledge and belief. Date: 77o /p/
COMPREHENSIVE PLAN (ENDMENT APPLICATION Page 2
8. COMPREHENSIVE PLAN AMENDMENT CRITERIA
/I/0A 6 n s/ � � eevelor92
5. COMPREHENSIVE PLAN Existing:
DESIGNATION Proposed:
6. ZONING: Existing: .0 . Proposed: C —1
7. USE: Existing: ti a c.
Proposed: ?, v Y o s q F+ e o 0 u, r•-c r a, /
The burden of proof in demonstrating that the change is appropriate lies solely upon the
proponent. Generally, the more dramatic the change, the greater will be the burden of
showing that the proposed change meets the criteria by the Zoning Ordinance. The
proponent must show in a dear and precise manner why the amendment application should
be granted. The Planning Commission and City Council will review your proposal using the
following criteria. You may attach additional sheets and submit other documentation to
support your request.
A. Unforeseen changes in circumstances have occurred in community conditions that
justify a Comprehensive Plan redesignation of the subject property or existing plan
policies. (Examples are Functional road classifications or new or changed City
policies /plans.)
RESPONSE: 1 %..,(e f erl.i ap s Mt
ro,N� ,� tk r 11;41" /4;1e /J✓Y'a
a n err) 40 r aalrrr vn t" ,04 4;-
B. Factual evidence supports an additional or changed public need for the proposed
designation.
uv, F c c 5 ccc. ni1oii CamLly
6P our proposal /fo tea /Pd
S�rdicJe1
RESPONSE: I✓1 c (udc:, .r1A►n woad e.or•doni in lust Cthc Nor'? f4 1 1,ciritw fT
TIYA.,e are ,7i /la s7 ,3o d iv r// gnr7 can ,or'o er 7` wit4
So / o f our _s-
9. To supplement the above criteria discussion, analyze the Tukwila Comprehensive Plan
policies which relate to your proposed Comprehensive Plan amendment. Identify the
policies and their page numbers and how your proposal affects them.
RESPONSE: 64 s P r Q c, 4 e c/
CITY OF TUKWILA
DEPARTMENT OF COMMUNITY DEVELOPMENT
1. BRIEFLY DESCRIBE YOUR PROPOSAL: Q e z o n From 4 O . 7o C –
2. PROJECT LOCATION: (Give street address or, if vacant, indicate lot(s), block, and sub-
division; or tax lot number, access street, and nearest intersection)
5 go Sou 1'G e.ewfer b
Quarter: a3 Section: a3 Township: S/ Range: E
(This information may be found on your tax statement)
3. APPLICANT:* Name: L. i on G s e Geseoe °eve/epho„ 1 I' vic ...
• Address: 7 Co L " S ( S0.11‘. S.ii .10 viola. iji 9 ?
,Q ho .— g -37
Signature: 22gto . Date: 7�io/g/
* The applicant is the person whom the staff will contact regarding the application, and
to whom all notices and reports shall be sent, unless otherwise stipulated by applicant.
AFFIDAVIT OF OWNERSHIP
4. PROPERTY Name: G e,Gov - i9 u 4 om t-T L-
OWNER
Address: '7 co (. 91 S. l< e Klan.✓ wit 7i-033
Phone: 8?& - 3 )oJ
I /WE,[signature(s)1 v/ d/te) � � �
swear that I /we are the owner(s) or contract purchaser(s) of the property involved
in this application and that the foregoing statements and answers contained in this
application are true and correct to the
best of my /our knowledge and belief. Date: ?//Q1�/1
R��ONE .� (���'�1�[ .��j
APPLICATI N !uL 1 2 1991
6300 Southcenter Boulevkd,_.Tfrliti ` X- 88 ....„
Telephone: (206) 431 -3680
REZONE APPLICATION ir Page 2
5. What is the current zoning of the property? P.O.
6. What is the size of the property? / o a uuA
7. What zoning classification is requested? C —
8. What is the comprehensive land use map designation? L. O sI ty e s i 619 AI/ a,,1
CRITERIA
The burden of proof in demonstrating that the change is appropriate lies solely upon the proponent.
Generally, the more dramatic the change, the greater will be the burden of showing that the proposed change
is in conformance with the Comprehensive Plan as implemented by the Zoning Ordinance. The proponent
must show in a clear and precise manner why the rezoning application should be granted. The Planning
Commission and City Council will review your proposal using the following criteria. You may attach
additional sheets and submit other documentation to support your rezone application.
1. The use or change in zoning requested shall be in conformity with the adopted compre-
hensive land use policy plan, the provisions of this title, and the public interest.
J/ 1
RESPONSE: Please see e.nn'- o,'e Ai eitr, ✓P / /ail 7», t i ijt64 7 1/�eQ /on
2. The use or change in zoning requested in the zoning map or this title for the establishment
of commercial, industrial, or residential use shall be supported by an architectural site
plan showing the proposed development and its relationship to surrounding areas as set
forth in the application form.
RESPONSE: P /rivr< -cc 4 eo/ s /f"e Ala a
S �� c.
3. When the request is not in agreement with the Comprehensive Land Use Policy Plan, the
applicant shall provide evidence to the City Council's satisfaction that there is an
additional need for the requested land classification.
(go to next page)
fIEZONE APPLICATION
RESPONSE: P to
Page 3
s p p lah amse6(m,.i f 40, /ca
4. Significant changes have occurred in the character, conditions or surrounding neighbor-
hood that justify or otherwise substantiate the proposed rezone.
RESPONSE: eoptd I2uff; - Fa0;r/ ,17 rew1-1 r :, e 7/# /, r y ob
h4s C1 v 4. el for aO�/C1r.Pn 7` fa rev ax. e . ti
r/"4 / n 7`/ie►c 7� O F df a 6/e !�i / S /.a r r � F'O I� G.� b.,- � 4 I,„ tt ►^ h
LA,/ / S ev✓ e 7`�! uG�� w(�for/ G!i a'rr &DrDf /isJ /fit
4 7 /1dc 7 ' f , (/7 -5 /t s c or07al', C/o /
< t Peee- tee l.
5. The proposed rezone is in the best interest of public health and safety as compared to the
hardship, such as diminution of property value, imposed on the individual property
owner.
RESPONSE: "4 s e /I Se a / a c, �vo a, . Dar pc0/ q 1 g erg es 14 o
u 61/C. ,,,,� i n ∎
/ Cr'asu. / /r/ cC /'l /0d. Ot'r
e /e A
/ c., 2 l alai' / ` %ic r
L ' JC /'" 7�!? <v', /d'r� ih r 0 n y 41,./ 1- // / 7 cos L..
Wou /00 6e / ^ t .71- ^4 o a lor4 / c eFFic./ s`7�"k 6 f.
6. The unimproved subject property is unsuitable for the purpose for which it has been
zoned considered in the context of the length of time the property has remained unim-
proved and land development in the surrounding area.
RESPONSE: A, t S"« // 6 hue
di 0 / rfie�t . S •rbOde /'r. 664c.r use.
1W /7`/. /6/ 74s /6 7L /c4474 5,7_,
S 7�P e / O M a t ti 10 , /7 r ,S u 7 7a c o 04. or ■ rc / a/ // r
tf-9 14/f/ Al) 9�' 2 iu 7'�.e s 7�re c 5.0/e or ?//
c.e V w � rC-4 1 c . /// re t /. ( 7 % %K 07 a/ —I/ 64:s
afwa