HomeMy WebLinkAboutPermit D06-203 - Upland Distribution - Building 294 -Seismic RetrofiftUPLAND DISTRIBUTION
BUILDING 294
1105 ANDOVER PK W
D06 -203
Parcel No.: 3523049110
Address: 1105 ANDOVER PK W TUKW
Suite No:
Tenant:
Name: UPLAND DISTRIBUTION - BLDG 294
Address: 1105 ANDOVER PK W, TUKWILA WA
Owner:
Name: TWO NINE THREE & FOUR LTD
Address 1325 4TH AVE SUITE 1940, SEATTLE WA
Value of Construction: $50,100.00
Type of Fire Protection: SPRINKLERS
Type of Construction: IIB
Public Works Activities:
City of Tukwila
Department of Community Development / 6300 Southcenter BL, Suite 100 / Tukwila, WA 98188 / (206) 431 -3670
Channelization / Striping: N
Curb Cut / Access / Sidewalk / CSS: N
doe: Devperm
DEVELOPMENT PERMIT
Permit Number: D06 -203
Issue Date: 07/06/2006
Permit Expires On: 01/02/2007
Phone:
Contact Person:
Name: HEATHER LEAMAN Phone: 206 624 -3210
Address: 603 STEWART ST #707, SEATTLE WA
Contractor:
Name: SAUNDERS CONSTRUCTION INC Phone: 949 646 -0034
Address: 1760 MONROVIA AV UNIT A -1, COSTA MESA CA
Contractor License No: SAUNDCI953ND Expiration Date:08 /04/2007
DESCRIPTION OF WORK:
VOLUNTARY SEISMIC RETROFIT OF WALL ANCHORAGE AND CONTINUITY TIES.
Water Main Extension: N Private: Public:
Water Meter: N
** Continued Next Page "
Fees Collected: $1,335.49
Uniform Building Code Edition:
Occupancy per UBC: 0011
Fire Loop Hydrant: N Number: 0 Size (Inches): 0
Flood Control Zone: N
Hauling: N Start Time: End Time:
Land Altering: N Volumes: Cut 0 c.y. Fill 0 c.y.
Landscape Irrigation: N
Moving Oversize Load: N Start Time: End Time:
Sanitary Side Sewer: N
Sewer Main Extension: N Private: Public:
Storm Drainage: N
Street Use: N Profit: N Non - Profit: N
D06 -203 Printed: 07 -06 -2006
doc: Devperm
City of Tukwila
Department of Community Development / 6300 Southcenter BL, Suite 100 / Tukwila, WA 98188 / (206) 431 -3670
Permit Center Authorized Signature MVtA A/1S1&M Date: hi-lap t00
I hereby certify that I have read and x in d t is permit and know the same to be true and correct. All provisions of law and
ordinances governing this work will b mp with, whether specified herein or not.
The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws
regulating construction or the performance of work. II am authorized to sign and obtain this development permit. fs Signature: wMv"' 0 - • Date: 7'(?"0(0
Print Name: Jo ANN A • 8 A H i f t ` 4 ( A . ‘ 1 7 PIloP MGR
This permit shall become null and void if the work is not commenced within 180 days from the date of issuance or if the work is
suspended or abandoned for a period of 180 days from the last inspection.
006 -203 Printed: 07 -06 -2006
City oVfukwila
Parcel No.: 3523049110
Address: 1105 ANDOVER PK W TUKW
Suite No:
Tenant: UPLAND DISTRIBUTION - BLDG 294
1: ***BUILDING DEPARTMENT CONDITIONS***
13: "'FIRE DEPARTMENT CONDITIONS***
doc: Conditions
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206 -431 -3670
Fax: 206 -431 -3665
Web site: cttukwila.wa.us
PERMIT CONDITIONS
Steven M. Mullet, Mayor
Steve Lancaster, Director
Permit Number: D06 -203
Status: ISSUED
Applied Date: 05/31/2006
Issue Date: 07/06/2006
2: No changes shall be made to the approved plans unless approved by the design professional in responsible charge and the
Building Official.
3: All permits, inspection records, and approved plans shall be at the job site and available to the inspectors prior to
start of any construction. These documents shall be maintained and made available until final inspection approval is
granted.
4: The special inspections and verifications for concrete construction shall be required.
5: The special inspections for steel elements of buildings and structures shall be required. All welding shall be done by
a Washington Association of Building Official Certified welder.
6: Installation of high- strength bolts shall be periodically inspected in accordance with AISC specifications.
7: The special inspection of bolts to be installed in concrete prior to and during placement of concrete.
8: When special inspection is required, either the owner or the registered design professional in responsible charge,
shall employ a special inspection agency and notify the Building Official of the appointment prior to the first
building Inspection. The special inspector shall furnish inspection reports to the Building Official in a timely manner.
9: A final report documenting required special inspections and correction of any discrepancies noted in the inspections
shall be submitted to the Building Official. The final inspection report shall be prepared by the approved special
inspection agency and shall be submitted to the Building Official prior to and as a condition of final inspection
approval.
10: All construction shall be done in conformance with the approved plans and the requirements of the International
Building Code or International Residential Code, International Mechanical Code, Washington State Energy Code.
11: All electrical work shall be inspected and approved under a separate permit issued by the Washington State Department
of Labor and Industries (206/248- 6630).
12: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of,
any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits
presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila
shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the
Building Official from requiring the correction of errors in the construction documents and other data.
14: The attached set of building plans have been reviewed by the Fire Prevention Bureau and are acceptable with the
following concerns:
15: Maintain existing sprinkler system piping, bracing and coverage. New brackets, beams, etc. must not obstruct sprinkler
D06 -203 Printed: 07-06-2006
head discharge in any way.
doc: Conditions
City theTukwila
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206 -431 -3670
Fax: 206 -431 -3665
Web site: ci.tukwila.wa.us
* *continued on next page**
Steven M. Mullet, Mayor
Steve Lancaster, Director
16: All new sprinkler systems and all modifications to existing sprinkler systems shall have fire department review and
approval of drawings prior to installation or modification. New sprinkler systems and all modifications to sprinkler
systems involving more than 50 heads shall have the written approval of the W.S.R.B., Factory Mutual, Industrial Risk
Insurers Kemper or any other representative designated and /or recognized by the City of Tukwila, prior to submittal to
the Tukwila Fire Prevention Bureau. No sprinkler work shall commence without approved drawings. (City Ordinance #2050)
17: Any overlooked hazardous condition and /or violation of the adopted Fire or Building Codes does not imply approval of
such condition or violation.
18: These plans were reviewed by Inspector 511. If you have any questions, please call Tukwila Fire Prevention Bureau at
(206)575 -4407.
006 -203 Printed: 07 -06 -2006
City ok'Tukwila
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206 -431 -3670
Fax: 206 -431 -3665
Web site: ct.tukwila.wa.us
Steven M. Mullet, Mayor
Steve Lancaster, Director
I hereby certify that I have read these conditions and will comply with them as outlined. All provisions of law and ordinances
governing this work will be complied with, whether specified herein or not.
The granting of this permit does not presume to give authority to violate or cancel the provision of any other work or local laws
regulating construction or the performance of work.
Signature:
Print Name:
doc: Conditions
t att Q. f "-'
Jb ON A • IMt4 , RsCT PPP MGR
Date: 7-6 -06
D06 -203 Printed: 07-06-2006
Company Name:
Mailing Address:
Q ApPIicstions\Ponns- Appliatiou On line 3 -1006 - Pnmil Application.doc
Revised: 4-2006
bit
.
CITY OF TUKWIUted
Community Development Department
Public Works Department
Permit Center
6300 Southcenter Blvd., Suite 100
Tukwila, WA 98188
http :Nwww.ci.tukwila. wa. us
Building Permit No. " Z '
Mechanical Permit No.
Plumbing /Gas Permit No.
Public Works Permit No.
Project No.
(Far o cQ use only)
Applications and plans must be complete in order to be accepted for plan review.
Applications will not be accepted through the mail or by fax.
**Please Print"
Site Address:)( . OcNQkJr•- t1( 7r
G s ►W J I1. _.�ll'
N.
Tenant Name:
Property Owners Name: PAM, ¶Ftl t t ctv- PGFaltO 4
Mailing Address: 1 2121 k uoPr give- two T Alr -vousr (pint I blit
state
Name: f (f — 1 £t4A .
1.1Loa
Mailing Address: ■.�
E-Mail Address: ( le)r' -ccwl
'GE1$$ERAL GONTRACTORINFORMATION
(Contractor Information for Mechanical (pg 4)`fo'r Pldmbing' Gas Piping'(pg 5) ):
Company Name: 7�
Mailing Address:
City
Day Telephone:
Fax Number:
Expiration Date:
Contact Person:
E-Mail Address:
Contractor Registration Number:
7ARCIIITECT OF RECORD =Alt plods must be'wet stamped by Architect of Record
Company Name:
Mailing Address:
Contact Person:
E-Mail Address:
NGINEER'OF RECORD — All plans must be wet stamped by Engineer of Record
King Co Assessor's Tax No.: 7J 2- 49 1 d Q .
Suite Number: Floor:
New Tenant: ❑ Yes K.No
Day Telephone: sure (Q 2-ft *2-1 0
. ,a11 10
city sta e zi p
Fax Number: Sae te i4 2 7
State
State
Zip
City
Day Telephone:
Fax Number:
Zip
iry State �_
Day Telephone: ±1 (o Fi�Lr� D
Contact Person:
E -Mail Address: Fax Number: 242 en (
Page 1 of 6
BUILDING PERMIT INFORA ION - 206 -431 -3670 -
Valuation of Project (contractor's bid price): $ "/a 1 - aO
Scope of Work (please provide detailed information):
Number of Parking Stalls Provided: Standard:
FIRE PROTECTION/HAZARDOUS MATERIALS:
l Sprinklers 0-Automatic Fire Alarm ❑..None
QMpplicadomlFwms- Applicalioor On reneV- 2006 - Permit Applicadon.doc
Revised: 4-2006
bh
or sou .
Existing Building Valuation: $
:r✓.�.. tagta l
[L- - "9 Fe
Will there be new rack storage? ❑ -Yes 'No (If yes, a separate permit and plan submittal will be required)
Provide All Building Areas in Square Footage Below
1 "Floor
2 Floor
3' Floor
Floors
:Basement
Accessory Structure'
Attached Garage
Detached Garage
Attached Carport .
Detached Carport
! Covered Deck
Unbovered
Existing
Interior
Remodel
Addition to
Existing
New
Type of
Construction
per IBC
Type Of
.Occupancy per
IBC - •
PLANNING DIVISION:
Single- family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches)
*For an Accessory dwelling, provide the following:
Lot Area (sq ft): Floor area of principal dwelling: Floor area for accessory dwelling:
*Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence.
Compact: Handicap:
Will there be a change in use? ❑ ....Yes ❑..No If "yes ", explain:
❑ ..Other (specify)
Will there be storage or use of flammable, combustible or hazardous materials in the building? ❑.. Yes No
If "yes", attach list of materials and storage locations on a separate 8 - 1/2 x 11 paper indicating quantities and Material Safety Data Sheets.
SEPTIC SYSTEM:
❑ On - site Septic System - For on -site septic system, provide 2 copies of a current septic design approved by King County Health
Department.
Page 2 of 6
PUBLIC WORKS PERMIT INIvoRMATION — 206-433-0179
Scope of Work (please provide detailed information):
Please refer to Public Works Bulletin #1 for fees and estimate sheet.
Water District
❑...Tukwila ❑...Water District #I25
❑ ...Water Availability Provided
wer District
...Tukwila ❑...ValVue
❑ ...Sewer Use Certificate 0... Sewer Availability Provided
Submitted with Application (mark boxes which auolv):
❑ ...Civil Plans (Maximum Paper Size — 22" x 34")
❑ ...Technical Information Report (Storm Drainage)
❑ ...Bond ❑ .. Insurance ❑ .. Easement(s)
Proposed Activities (mark boxes that apply):
❑ ...Right -of -way Use - Nonprofit for less than 72 hours
❑...Rightof -way Use - No Disturbance
❑ ...Construction/Excavation/Fill - Right-of-way
Non Right-of-way
❑ ...Total Cut cubic yards
❑ ...Total Fill cubic yards
❑ ...Sanita Side Sewer ❑ .. Abandon Septic Tank
❑ ...Cap or Remove Utilities ❑ .. Curb Cut
❑ ...Frontage Improvements ❑ .. Pavement Cut
❑ ...Traffic Control ❑ .. Looped Fire Line
❑ ...Backflow Prevention - Fire Protection "
irrigation
Domestic Water
❑ ...Permanent Water Meter Size..
❑ ...Temporary Water Meter Size ..
❑...Water Only Meter Size
VI
Q:UppIatioa\Pams-Applications On line- 2006 - Permit Applicalion.doc
Revised: 4-2006
bb
Call before you Dig: 1400 -424 -5555
❑ ...Sewer Main Extension Public _ Private _
❑ ...Water Main Extension Public _ Private _
❑ .. Highline
❑ .. Geotechnical Report
❑ .. Maintenance Agreement(s)
❑ .. Work in Flood Zone
❑ .. Storm Drainage
❑ .. Renton
❑..Renton 0.. Seattle
❑ .. Approved Septic Plans Provided
❑ .. Right-of-way Use - Profit for less than 72 hours
❑ .. Right-of-way Use — Potential Disturbance
❑...Traffic Impact Analysis
❑...Hold Harmless — (SAO)
❑...Hold Harmless — (ROW)
❑ .. Grease Interceptor
❑ .. Channelization
❑ .. Trench Excavation
❑ .. Utility Undergrounding
❑ ...Deduct Water Meter Size
FINANCE INFORMATION
Fire Line Size at Property Line
❑ ...Water ❑ ...Sewer ❑ ...Sewa Treatment
Monthly Service Billinp to:
Name:
Number of Public Fire Hydrant(s)
Day Telephone:
Mailing Address:
City State Zip
Water Meter RefundBilling_
Name: Day Telephone:
Mailing Address:
City
State
Zip
Page 3 of 6
PERMIT APPLICATION NO] i - Applicable to all permits in this :ipylication
BUILDING
Signature:
Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject
to possible revision by the Permit Center to comply with current fee schedules.
Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation.
Building and Mechanical Permit
The Building Official may grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be
requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition).
phtmbing Permit
The Building Official may grant one extension of time for an additional period not exceeding 180 days. The extension shall be requested
in writing and justifiable cause demonstrated. Section 103.4.3 Uniform Plumbing code (current edition).
I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER
PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT.
1 Date Application Accepted:
imim id,
QMpplicatiot \PonnsAppliadone On Line n•2006 - Pemtit Application.doc
Revised: 42006
m
ENT:
Print Name: , 1o/"1 ✓74
Date:
Day Telephone: Ake e/2-1 %
Mailin Address: ( 7 - e *in ,�.� (1 - 0 (rJ '
City State Zip
Date Application Expires: 1 t i `
Page 6 of' 6
RECEIPT NO: R06 -00978
Payment Date: 07 /06/2006
User ID: 1165 Total Payment: 2,767.88
Initials: JEM
Payee: AMB ALLIANCE FUND III, LLC
SET ID: 0706 SET NAME: SEISMIC RETROFITS
SET TRANSACTIONS:
Set Member Amount
D06 -200
D06 -201
D06 -202
D06 -203
TOTAL:
TRANSACTION LIST:
Type Method Description
Payment Check 0200136
ACCOUNT ITEM LIST:
Description
614.68
602.16
739.88
811.16
2,767.88
BUILDING - NONRES
STATE BUILDING SURCHARGE
City of Tukwila
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206 -431 -3670
Fax: 206 -431 -3665
SET RECEIPT
TOTAL:
Amount
2,767.88
2,767.88
Account Code Current Pmts
000/322.100 2,749.88
000/386.904 18.00
TOTAL: 2,767.88
71.35 07/07 9710 TOTAL 2767.88
Steven M. Mullet, Mayor
Steve Lancaster, Director
RECEIPT NO: R06 -00769
Initials: JEM
Payee: R. 3. HALLISSEY CO, INC.
SET ID: 053106
SET TRANSACTIONS:
Set Member Amount
D06 -200 396.62
D06 -201 388.48
D06 -202 478.00
D06 -203 524.33
TOTAL: 1,787.43
TRANSACTION LIST:
Type Method Description
Payment Check 7129
City of Tukwila
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206431 -3670
Fax: 206431 -3665
SET RECEIPT
Copy Reprinted on 05 -31 -2006 at 15:20:46 05/31/2006
Payment Date: 05/31/2006
User ID: 1165 Total Payment:1,787.43
SET NAME: SEISMIC RETROFIT
TOTAL:
Amount
1,787.43
1,787.43
ACCOUNT ITEM LIST:
Description Account Code Current Pmts
PLAN CHECK - NONRES 000/345.830 1,787.43
TOTAL: 1,787.43
5976 06/01 9716 TOTAL 1787.43
Steven M. Mullet, Mayor
Steve Lancaster, Director
Project: ,.
2 /?ZA,d) drSi
Type ofIns ection:
r, r11 4 /
Address:
/ I O 5 471/rIa4( / LL/
Date Called:
Special Instructions:
Date Wanted:
/ 2 - / - o i�
,, am..
(� =
Requester:
Phone No:
INSPE NO. PERMIT NO.
CITY OF TUKWILA BUILDING DIVISION
6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -36 #0
Approved per applicable codes. Corrections required prior to approval.
INSPECTION RECORD
Retain a copy with permit
COMMENTS:
ctor:
Date:
2 - e1e
$58.00 REINSPE ON FEE RE/ • RED. Prior to inspection, fee must be
paid at 6300 Sout center Blvd., Suite 100. Call to sechedule reinspection.
Receipt No.:
'Date:
Project:
?/A4,3/V7) ,,/)AS i.
Type of Inspection: •
A e9 /!i /et/ 6
Address: /.
///] 'S 4Air/rv'v ik 4
,
Date Called:
Special Instructions:
Date Wanted: c
r y.:
Requester:
Phone No:
4 2 0 ?S/ -of 3
Approved per applicable codes.
Corrections required prior to approval.
COMMENTS:
0 /711 is
1 / /d' /��o✓/s r•J .0
s /•
j /_ / AM.A -...." 014_
INSPECTION RECORD
7 Retain a copy with permit
INSPECTION NO.
CITY OF TUKWILA BUILDING DIVISION
Do4 -zo
PERMIT
6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206,
D $58.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be
paid at 6300 Southcenter Blvd., Suite 100. Call to sechedule reinspection.
Receipt No.:
'Date:
Project:
21P U 131-
Type of I ec n: ^
`,
Address:
\ ►O AaDduet Vt tA.i
Date Called:
Special Instructions:
Q t Al ZG
Wad: //
a- I I — 00 It
Cr
p.m.
Requester:
Phone No:
Z p_ZS( -656-4
INSP CfION NO.
INSPECTION RECORD
Retain a copy with permit
CITY OF TUKWILA BUILDING DIVISION
6300 Southcenter Blvd., #100, Tukwila, WA 98188 (2
Approved per applicable codes. Corrections required prior to approval.
COMMENTS:
s1- (°tsNiar4 a N j(4
? Natty\
IDate:
1 i
0 S 58 00 REINSPECTION FEE REQUIRED. 'or to inspection, fee must be
Fa'• at 6300 Southcenter Blvd., Suite 00. Call to sechedule reinspection.
(Receipt No.: Date:
Project: /
ttf (vino '0 o s! . C a Jilt et—
Type of Inspection:
ilYet AP* 1-
Address.
ti OS A &L LL el( W
Suite #:
Contact Person:
C-Aitt s 110 j eNCt A
Special Instructions:
Phone No.:
Monitor: 11 C>r
Needs Shift Inspection: A
Sprinklers: 9'
Fire Alarm: /,./
Hood & Duct: ,tt/
Monitor: 11 C>r
Pre -Fire:
Permits:
Occupancy Type:
51
INSPECTION NUMBER
r7
1 . ..Approved per applicable codes.
INSPECTION RECORD
Retain a copy with permit
CITY OF TUKWILA FIRE DEPARTMENT
Word /Inspection Record Form.Doc 1/13/06
ho (7 - a-o 3
PERMIT NUMBERS
444 Andover Park East, Tukwila, Wa. 98188 206 - 575 -4407
Corrections required prior to approval.
COMMENTS:
A 0-c f- icA4 L e_e•
Inspector: 5 7 L./ it
Date: ), jgi
Hrs.: . S
IQ /i) n $80.00 REINSPECTION FEE REQUIRED. You will receive an invoice from
the City of Tukwila Finance Department. Call to schedule a reinspection.
T.F.D. Form F.P. 113
MAYES TESTING ENGINEERS, INC.
MTE NO: T6135
PROJECT: UPLAND DISTRIBUTION CENTER SEISMIC UPGRADE
Address: 1105 Andover Park W.
Tukwila, WA
PERMIT NO: D06 -203
Page 15
Owner: J.S. Dyer & Associates
Architect: --
Engineer: —
Contractor: Saunders Construction
Date: 9 -27-06
Weather: Inside
Inspection: Epoxy
Samples: N/A
MTE inspector arrived on site to monitor the installation of epoxy anchors per details 2 and 5/S3.
Building 294, grids A and F by 15 to 18 and A to F by 18. Simpson Epoxy Tie Set 22 was installed
per manufacturers instructions.
To the best of our knowledge, items inspected this date are in accordance with approved plans
and specifications.
cc: Jeffrey Dyer, J.S. Dyer & Associates
Sungbae Moon, Saunders Construction
JoAnn Bahian, AMB Property Corp
Building Official, City of Tukwila
Reviewed by:
RECEIVED
Everett Office
Suite - 1h Street SW
OCT' 1 2006
Suite A -1
Everett, WA 98204
COMMUNITY ph 425.742.9360
DEVELOPMENT fax 425.745.1737
INSPECTOR: Mat Taylor
Tacoma Office
10029 S. Tacoma Way
Suite E -2
Tacoma, WA 98499
ph 253.584.3720
fax 253.584.3707
Portland Office
7911 NE 33rd Drive
Suite 190
Portland, OR 97211
ph 503.281.7515
fax 503.281.7579
Dennis Sanborn, Branch Manager
RECEIVED
MAYES TESTING ENGINEERS, INC. SEP 2 6 2006
COMMUNITY
DEVELOPMENT
MTE NO: T6135
PROJECT: UPLAND DISTRIBUTION CENTER SEISMIC UPGRADE
Address: 1105 Andover Park W.
Tukwila, WA
PERMIT NO: 006 -203
Page 13
Owner. J.S. Dyer & Associates
Architect:
Engineer:
Contractor: Saunders Construction
Date: 9 -14-06
Weather: Inside
Inspection: Epoxy
Samples: N/A
MTE inspector arrived on site to observe the installation of threaded rods using Simpson Set 22
Epoxy per details on 2A/S3 and 3/S3 at building #294, unit #1115. Holes were drilled to 3' 'A"
depth and %" or 7/8" diameter for 5/8" or %" anchor rods per schedule on S3. Epoxy lot
#14940011 with expiration date 02/08. Two anchors placed at each purlin on lines A and F
between 11 and 15 line. The %" anchors were placed at 11/A, 11/F and 11.5/A. All other locations
used 5/8 "diameter threaded rods. All locations were brushed and blown clean prior to injecting
epoxy. No deficiencies noted.
To the best of our knowledge, items inspected this date are in accordance with approved plans
and specifications.
cc: Jeffrey Dyer, J.S. Dyer & Associates
Sungbae Moon, Saunders Construction
JoAnn Bahian, AMB Property Corp
Building Official, City of Tukwila
INSPECTOR: Bob Gardner
Reviewed by
Everett Office
917 -134th Street SW
Sule A -1
Everett, WA 98204
ph 425.742.9360
fax 425.745.1737
Tacoma Office
10029 S. Tacoma Way
Suite E -2
Tacoma, WA 98499
ph 253.584.3720
fax 253.584.3707
Portland Office
7911 NE 33rd Drive
Suite 190
Portland, OR 97211
ph 503.281.7515
fax 503 281 7579
is Sanborn, Branch Manager
MAYES TESTING ENGINEERS, INC.
Page 12
MTE NO: T6135
PROJECT: UPLAND DISTRIBUTION
Address: 1105 Andover Park W.
Tukwila, WA
PERMIT NO: D06 -203
Owner. J.S. Dyer & Associates
Architect:
Engineer.
Contractor: Saunders Construction
Date: 9 -9-06
Weather. Clear
Inspection: Epoxy
Samples: N/A
REt ENEID
SEF 2 6 2006,
DAM° A AM'
CENTER SEISMIC UPGRAE
Everett Office
917 -134th Street SW
Suite A -1
Everett, WA 98204
ph 425742.9360
fax 425.745.1737
Tacoma Office
10029 S. Tacoma Way
Suite E -2
Tacoma, WA 98499
ph 253.5843720
fax 253 584 3707
Portland Office
7911 NE 33rd Drive
Suite 190
Portland, OR 97211
ph 503.281.7515
fax 503.281.7579
MTE inspector arrived onsite and inspected the installation of epoxy anchors at building #293
line A/6 -7. The HD -2A's were attached to purlins. The threaded rods were embedded in
concrete 3 W minimum. The area was clean and dry. The rods were fully grouted with
Simpson Set Epoxy, lot #14940011, and expiration date 02/08 with a total of 7 sets installed.
Epoxy anchors installed at building #294, line G/1 -2 & 6 -7. A total of 12 sets of rods and HD-
2A's placed. Sets of rods and HD -2A's installed at line 1/D & E. Sub purlin anchorage installed
at line 1/D.3, D.6, E.3 and E.6. The full assembly as detailed on 5/S3 was installed anchored
with Simpson Set Epoxy at concrete wall.
To the best of our knowledge, items inspected this date are in accordance with approved plans
and specifications.
cc: Jeffrey Dyer, J.S. Dyer & Associates
Sungbae Moon, Saunders Construction
JoAnn Bahian, AMB Property Corp
Building Official, City of Tukwila
Reviewed by:
INSPECTOR: Jeff Van Blaricom
is Sanborn, Branch Manager
MAYES TESTING ENGINEERS, INC. RECEIVED
ELOPb
MTE NO: T6135 DEV
PROJECT: UPLAND DISTRIBUTION CENTER SEISMIC UPGRADE
Address: 1105 Andover Park W.
Tukwila, WA
PERMIT NO: D06 -203
Page 11
Owner: J.S. Dyer & Associates
Architect:
Engineer:
Contractor: Saunders Construction
Date: 9 -6-06
Weather: Sunny
Inspection: Epoxy
Samples: N/A
MTE inspector arrived on site to monitor the installation of 100+ epoxy all thread anchors for
seismic connectors per detail 2/S3, in building #425 grids A to G by 4 to 8, G3 and G12. Simpson
Set 22 Epoxy (expiration date 02/08) was installed per manufacturers written instructions.
To the best of our knowledge, items inspected this date are in accordance with approved plans
and specifications.
cc: Jeffrey Dyer, J.S. Dyer & Associates
Sungbae Moon, Saunders Construction
JoAnn Bahian, AMB Property Corp
Building Official, City of Tukwila
Reviewed by:
SEP 21 20091
INSPECTOR: Mat Taylor
Everett Office
917 -134th Street SW
Suite A -1
Everett, WA 98204
ph 425.742.9360
fax 425.745.1737
Tacoma Office
10029 S. Tacoma Way
Suite E -2
Tacoma, WA 98499
ph 253 584 3720
fax 253.584.3707
Portland Office
7911 NE 33rd Drive
Suite 190
Portland, OR 97211
ph 503.281.7515
fax 503.281.7579
Dennis Sanborn, Branch Manager
MAYES TESTING ENGINEERS, INC.
MTE NO: T6135
PROJECT: UPLAND DISTRIBUTION CENTER SEISMIC UPGRADE
Address: 1105 Andover Park W.
Tukwila, WA
PERMIT NO: D06 -203
Page 10 RECEIVED
Owner: J.S. Dyer & Associates S 1 4 COs
Architect: COMMUNITY
DEVELOPMENT
Engineer.
Contractor: Saunders Construction
Date: 9 -2-06
Weather: Clear
Inspection: Epoxy
Samples: N/A
cc: Jeffrey Dyer, J.S. Dyer & Associates
Sungbae Moon, Saunders Construction
JoAnn Bahian, AMB Property Corp
Building Official, City of Tukwila
Everett Office
917-134th Street SW
Suite A -1
Everett, WA 98204
ph 425.742.9360
tax 425.745.1737
Tacoma Office
10029 S.Tacorna Way
Suite E -2
Tacoma, WA 98499
ph 253.584.3720
tax 253.584.3707
Portland Office
7911 NE 33rd Drive
Suite 190
Portland, OR 97211
ph 503.281.7515
fax 503.281.7579
MTE inspector arrived on site and inspected the installation of 5/8" diameter threaded rods at
Purlin Anchorage. The rods were embedded 3' 'A" in wall panel. The area was clean and dry.
The holes were blown and brushed. A total of 72 rods installed at A & Wine 3 -6. The rods were
fully grouted with Simpson Set Adhesive Lot #20749011 with expiration date of 02/08. Simpson
HD -2A was installed at locations per details 2/S3.
To the best of our knowledge, items inspected this date are in accordance with approved plans
and specifications.
INSPECTOR: Jeff Van Blaricom
Reviewed by:
nnis Sanborn, Branch Manager
RECEIVED
MAYES TESTING ENGINEERS, INC. SEP 14 2006 Emma Office
917 -134th skeet SW
�-,,.. _ ...�._..- .u.....W..w ...__ " .: Suite A -1
bE OMMUN Everett, WA 99204
E) nn..__ T ph 425.742.9360
MTE NO: T6135 '� �1jy N 425.745.1737
PROJECT: UPLAND DISTRIBUTION CENTER SEISMIC UPGRADE Tacoma Office
10029 S. Tacoma Way
Address: 1105 Andover Park W. Suite E -2
Tukwila, WA Tacoma, WA 98499
ph 253.584.3720
PERMIT NO: D06 -203 fax 253.584.3707
Portland office
Page 9 7911 NE 33rd Drive
Suns 190
Dyer & Associates ph 5 03 . o.7
Owner: J.S. D 15
y ph 503.29,.75,5
Architect: --- fax 503.281.7579
Engineer:
Contractor: Saunders Construction
Date: 9 -1-06
Weather. Inside
Inspection: Epoxy
Samples: N/A
MTE inspector arrived on site as requested to observe installation of epoxy dowels in building 425
for seismic upgrade 166 epoxy all thread roads at location 1-4 lines A to G and 8 -12/A to G. Two
rafters in 1-4 and J rafters in 8 -12 left undone over offices, 15 hold downs on 12 line, 15 holdowns
on line 1 line 8 beam brackets 1 line, 8 beam brackets 12 line. All holes drilled to 3'/ "
embedment and cleaned per manufacturers specifications. No discrepancies noted.
To the best of our knowledge, items inspected this date are in accordance with approved plans
and specifications.
cc: Jeffrey Dyer, J.S. Dyer & Associates
Sungbae Moon, Saunders Construction
JoAnn Bahian, AMB Property Corp
Building Official, City of Tukwila
INSPECTOR: Barry Tuttle
Reviewed by:
is Sanborn, Branch Manager
MAYES TESTING ENGINEERS, INC. RECEIVED
SEP 14 2006
MTE NO: T6135 COMMUNITY
PROJECT: UPLAND DISTRIBUTION CENTER SEISMIRNIME
Address: 1105 Andover Park W.
Tukwila, WA
PERMIT NO: D06 -203
Page 8
Owner. J.S. Dyer & Associates
Architect:
Engineer:
Contractor: Saunders Construction
Date: 8 -30-06
Weather: Inside
Inspection: Epoxy
Samples: N/A
MTE inspector arrived on site as requested this day for special inspection of structural epoxy.
Building *47R
Per details 1/S3, 2A/S3 and 3/S3'44" all thread anchors were placed into existing concrete wall
panels at the roof level for attachment to wood beams at grids (G, 8.6 and 8.8 and 9.0 and 9.2
and 9.4 and 9.6 and 9.8 and bracket per 3/S.3 at 10.3). MTE verified hole dimensions (7/8" X 3
1 /2 ") and cleanliness prior to epoxy placement. Contractor used Simpson SET epoxy with an
expiration of 02/08. No exceptions were noted.
Today's inspection confirms completion of preliminary items listed on MTE report by Carl
Harrington dated 08/21/06 for: 1) Porteous fastener provided a letter dated 08/23/06 confirming
that the all- thread anchors supplied were ASTM A307, Grade A. This letter also included
specifications on all the other materials provided by them. (Washers, screws, nuts, etc.) 2)
Correct bracket was installed at 10.3, G per 3/S3. No other deficiencies were noted.
CORRECTIVE ACTIONS TAKEN: Preliminary issues resolved: 1) grade of materials
confirmed. 2) Correct bracket at G, 10.3 installed.
cc: Jeffrey Dyer, J.S. Dyer & Associates
Sungbae Moon, Saunders Construction
JoAnn Bahian, AMB Property Corp
Building Official, City of Tukwila
Reviewed 7th
INSPECTOR: Jaimie Gordon
Everett Office
917 -134th Street SW
Suite A - 1
Everett WA 98204
ph 425.742.9360
tax 425.745.1737
Tacoma Office
10029 S. Tacoma Way
Suite E -2
Tacoma, WA 98499
ph 253 584 3720
fax 253.584.3707
Portland Office
7911 NE 33rd Drive
Suite 190
Portland, OR 97211
ph 503.281.7515
fax 503.281.7579
To the best of our knowledge, items inspected this date are in accordance with approved plans
and specifications.
is Sanborn, Branch Manager
MAYES TESTING ENGINEERS, INC.
September 6, 2006
City of Tukwila
Building Department
6200 South Center Blvd
Tukwila, WA 98188 -8188
Attn.: Building Official
Re: Upland Distribution
Center Seismic Upgrade
1105 Andover Park W
Tukwila, WA
MTE Project No. T6135
Gentlemen,
This is to inform you that registered special inspections have been completed for this project as
per our reports, copies of which have been sent to you.
Special inspection was provided for:
Epoxy Grouted Anchors
To the best of our knowledge, all work inspected was either performed in accordance with, or
corrected to conform to, the city approved drawings, or engineer approved changes.
We trust that this provides you with the information which you require. Should you have any
questions give us a call.
Sincerely,
MAYES TESTING ENGINEERS INC.
Michael S. Dolder, P.E.
Vice President
cc: JoAnn Bahian — AMB Property Corp.
Jeffrey Dyer — J.S. Dyer and Associates
Sungbae Moon — Saunders Construction, Inc.
RECEIVED
SEP 1 1 2006
DEVELOPMENT
Everett Office
917 -134th Street SW
Suite A -1
Everett, WA 98204
ph 425.742.9360
fax 425.745.1737
Tacoma Office
10029 S Tacoma Way
Suite E -2
Tacoma, WA 98499
ph 253.584.3720
fax 253.584.3707
Portland Office
7911 NE 33rd Drive
Suite 190
Portland, OR 97211
ph 503.281.7515
fax 503.281.7579
Re ceive()
MAYES TESTING ENGINEERS, INC. 411 8 20ne
o coMm 1 "wT
MTE NO: T6135
PROJECT: UPLAND DISTRIBUTION CENTER SEISMIC UPGRADE
Address: 1105 Andover Park W.
Tukwila, WA
PERMIT NO: D06 -203
Page 7
Owner: J.S. Dyer & Associates
Architect:
Engineer, —
Contractor: Saunders Construction
Date: 8 -21-06
Weather. Sunny
Inspection: Epoxy
Samples: N/A
PRELIMINARY: Could not confirm if zinc all thread being used meets ASTM 307 or A36.
Incorrect bracket at 10. /G needs to be changed before epoxy application.
cc: Jeffrey Dyer, J.S. Dyer & Associates
Sungbae Moon, Saunders Construction
JoAnn Bahian, AMS Property Corp
Building Official, City of Tukwila
Reviewed by:
INSPECTOR: Carl Harrington
Everett Office
917-134th Street SW
Suite A -1
Everett, WA 98204
ph 425.742.9360
fax 425.745.1737
Tacoma Office
10029 S. Tacoma Way
Suite E -2
Tacoma, WA 98499
ph 253 584 3720
fax 253 584.3707
Portland Office
7911 NE 33rd Drive
Suite 190
Portland, OR 97211
ph 503.281.7515
fax 503.281.7579
MTE inspector arrived onsite and performed continuous epoxy inspection for the installation of
approximately 167 all thread anchors. Epoxy used was Simpson Set with an expiration date of
02/08. Holes were drilled with a roto- hammer, and then cleaned with a nylon brush and
compressed air. Anchors used are zinc all- thread. General notes specify ASTM A -307 or A36
threaded rod, page 51 of approved plans. MTE could not confirm if the all thread being used
met these specifications.
Anchors were installed at the top of the perimeter walls of building 426, along grid lines 1 and
12, and A and G. Anchors were not installed at the following locations yet: Purlins on G line at
approximately 8.6, 8.8, 9.0, 9.2, 9.4, 9.6 and 9.8. Also, at approximately 10.3/G the wrong
brackets were prepared but not yet installed. The contractor will correct before installation.
Should be bracket type specified on 3/S3.
Other brackets installed per plan details 2/S3, 3/S3, and 5/S3. Anchors embedded 3 /" per
detail 1/S3, 2/S3 anchors were Simpson HD -2A alternate for 2/S3 brackets anchors were 5/8°
installed in 3/6' holes. For 3/S3 and 5/S3 anchors were 3 /4° installed in 7/8" holes. Adhesive
was applied per manufacturers specifications confirmed cleanliness of anchor and hole.
orn, Branch Manager
MAYES TESTING ENGINEERS, INC. RECEIVED Everett
t SW
w- 7 -:::r : -. -, AUG 2 4 1006 En wAto4
C OMMUNITY fa 325 745.
MTE NO: T6135
DEV ELOPMENT
PROJECT: UPLAND DISTRIBUTION CENTER SEISMIC UPGRADE Tacoma Office
10029 Tacoma Way
Address: 1105 Andover Park W. suite E -2
Tukwila, WA lane, WA 98499
PERMIT NO: D06 -203 ph 253.584.3720 fax 253.584.3707
Portland Office
Page 6 7911 NE 33rd Drive
Suite 190
Portland, OR 97211
Owner: J.S. Dyer & Associates ph 503.281.7515
Architect: fex 5032817579
Engineer:
Contractor: Saunders Construction
Date: 8 -17 -06
Weather: Overcast
Inspection: Epoxy
Samples: N/A
MTE inspector arrived on site to monitor the installation of epoxy all thread anchors for seismic
upgrade. 5/8" and 'A" diameter were installed into the correct size by 3 W deep holes, that were
wire brushed and blown out. Anchors installed in building 293, grids A to D by 1, A by 1 to 3, and
G by 2 to 3. Simpson Set 22 Epoxy Tie was installed per manufacturers written instruction.
To the best of our knowledge, items inspected this date are in accordance with approved plans
and specifications.
cc: Jeffrey Dyer, J.S. Dyer & Associates
Sungbae Moon. Saunders Construction
JoAnn Bahian, AMB Property Corp
Building Official. City of Tukwila
Reviewed by:
INSPECTOR: Mat Taylor
s Sanborn, Branch Manager
MAYES TESTING ENGINEERS, INC.
MTE NO: T6135
PROJECT: UPLAND DISTRIBUTION CENTER SEISMIC UPGRADE
Address: 1105 Andover Park W.
Tukwila, WA
PERMIT NO: D06 -203
Page 5
Owner: J.S. Dyer & Associates
Architect:
Engineer:
Contractor: Saunders Construction
Date: 8 -3 -06
Weather: Inside
Inspection: Epoxy
Samples: N/A
cc J.S. Dyer 8 Associates
Saunders Construction
Building Official, City of Tukwila
REC RECEIVED
AUG i ll 2006
D MopmENT
INSPECTOR: Jaimie Gordon
Everett Office
917 -134th Street SW
Sulte A-1
Everett WA 98204
ph 425.742.9360
fax 425.745.1737
Tacoma Office
10029 S. Tacoma Way
Suite E -2
Tacoma, WA 98499
ph 253.584.3720
fax 253.584.3707
Portland Office
7911 NE 33rd Drive
Suite 190
Portland, OR 97211
ph 503.281.7515
fax 503.281.7579
MTE inspector arrived on site as requested this day for special inspection of structural epoxy.
Building # ?93
Per details 1/S3, 2A/S3 and 3/S3 %" all thread anchors were placed into existing concrete wall
panels at the roof level for attachment to wood beams at grids (A, 6 -9 and G, 7 -9). MTE
verified hole dimensions ( %" X 3'/ ") and cleanliness prior to epoxy placement. Contractor
used Simpson SET epoxy with and expiration of 02/08. No exceptions were noted.
To the best of our knowledge, items inspected this date are in accordance with approved plans
and specifications.
Reviewed by:
ennis Sanborn,9nch Manager
MAYES TESTING ENGINEERS, INC.
MTE NO: T6135
PROJECT: UPLAND DISTRIBUTION CENTER SEISMIC UPGRADE
Address' 1105 Andover Park W.
Tukwila, WA
PERMIT NO: D06 -203 RetelveD
Page 4G
11 1006
Owner J.S. Dyer & Associates b a o p
Architect:
Engineer:
Contractor: Saunders Construction
Date: 8 -2 -06
Weather: Cloudy
Inspection: Epoxy
Samples: N/A
Everett Office
917 -134th Street SW
Suite A -1
Everett, WA 98204
ph 425.742.9360
fax 425745.1737
Tacoma Office
10029 S. Tacoma Way
Suite E -2
Tacoma, WA 98499
ph 253.584.3720
fax 253.584.3707
Portland Office
7911 NE 33rd Drive
Suite 190
Portland, OR 97211
ph 503.281.7515
fax 503.281.7579
MTE inspector arrived onsite at building 294 for epoxy inspection. Inspected placement of
epoxied threaded rod anchors (5/8 ") with Simpson Strong Tie Set 22 (expires 02/08). Per
details 1 and 2/S3, all thread anchors were placed in the concrete wall panels, at the roof level
for attachment of beams and purlins on grid lines 9 to 7 east and west walls.
To the best of our knowledge, items inspected this date are in accordance with approved plans
and specifications.
cc: J.S. Dyer & Associates
Saunders Construction
Building Official, City of Tukwila
INSPECTORS: Jim R. Kay
Barry Tuttle
Reviewed by: (
Dennis Sanborn, i3i Manager
MAYES TESTING ENGINEERS, INC.
MTE NO: T6135
PROJECT: UPLAND DISTRIBUTION CENTER SEISMIC UPGRADE
Address: 1105 Andover Park W.
Tukwila, WA
PERMIT NO: D06 -203
Page 1
Owner: J.S. Dyer & Associates
Architect:
Engineer. —
Contractor: Saunders Construction
Date: 7 -17 -06
Weather: Inside
Inspection: Epoxy
Samples: N/A
MTE inspector arrived on site as requested this day for special inspection of structural epoxy.
Chris (site foreman for Saunders Construction) provided approved plans and permit for review
and was able to explain all required procedures for epoxy prior to inspection.
Per details 1/S3, 2A/S3 and 5/S3,'/," all thread anchors were placed into existing concrete wall
panels at the roof level for attachment to wood beams and purlins at grids (A &F, 1-4) and (1, A-
F). MTE verified hole dimensions (7/8" X 3 ") and cleanliness prior to epoxy placement.
Contractor used Simpson SET epoxy with and expiration of 02/08. No exceptions were noted.
To the best of our knowledge, items inspected this date are in accordance with approved plans
and specifications.
cc: J.S. Dyer 8 Associates
Saunders Construction
Building Official, City of Tukwila
Reviewed by:
RECEIVED
AUG 01 1006'
COMMUNITY
DEVELOPMENT
INSPECTOR: Jaimie Gordon
Everett Office
917 -13401 Street SW
Suite A -1
Everett, WA 98204
ph 425.742.9360
fax 425.745.1737
Tacoma Office
10029 S. Tacoma Way
Suite E -2
Tacoma, WA 98499
ph 253.584.3720
fax 253.584.3707
Portland Office
7911 NE 33rd Drive
Suite 190
Portland, OR 97211
ph 503.281.7515
fax 503281.7579
Sanborn, Branch Manager
RECEIVE
MAYES TESTING ENGINEERS, INC. " !UU28 P005
,.; _,....- M ...... ...
O OMM Uivny
L NT
MTE NO:
PROJECT:
Address:
PERMIT NO:
Page 2
T6135
UPLAND DISTRIBUTION CENTER SEISMIC UPGRADE
1105 Andover Park W.
J.S. Dyer & Associates
Owner:
Architect:
Engineer:
Contractor: Saunders Construction
Date: 7 -21-06
Weather: Inside
Inspection: Epoxy
Samples: N/A
Everett Office
917-134th Street SW
Suite 41
Everett, WA 98204
ph 425.742.9360
fax 425.745.1737
Tacoma Office
10029 S. Tacoma Way
Suite E -2
Tacoma, WA 98499
ph 253.584.3720
tax 253.584.3707
Portland Office
7911 NE 33rd Drive
Suite 190
Portland, OR 97211
ph 503.281.7515
fax 503.281.7579
MTE inspector arrived on site as requested this day for special inspection of structural epoxy.
Sungbe Moon (Saunders project manager) provided approved plans and permit for review and
was able explain all required procedures for epoxy prior to inspection.
Per details 1/S3, 2A/S3 %" all thread anchors were placed into existing concrete wall panels at
the roof level for attachment to wood beams at grids (4 -6, A &F). MTE verified hole dimensions
(7/8" X 3'/ ") and cleanliness prior to epoxy placement. Contractor used Simpson SET epoxy
with and expiration of 02/08. No exceptions were noted.
To the best of our knowledge, items inspected this date are in accordance with approved plans
and specifications.
cc: J.S. Dyer & Associates
Saunders Construction
INSPECTOR: Jaimie Gordon
Reviewed by:
is Sanborn, Branch Manager
Permit No,
Voluntary Seimic Retrofit
FILE copy ,
For
Plan r .. .
1-
Upland Distribution Center Building 294
1105 Andover Park West'
Tukwila, Washington 98188
REVIEWED FOR
CODE COMPLIANCE
erfr+r+ arm
JUN 1 6 2006
City Of Tukwila
BUTLDTN( nT11TSTON
RECEIVED
CITY OFTUKWIIA
MAY 31 2006
PERMIT CENTER
J.S. DYER & ASSOCIATES INC.
STRUCTURAL ENGINEERS
Voluntary Seismic Retrofit
for
Upland Distribution Center
Building 294
1105 Andover Park West
Tukwila, Washington 98188
May4, 2006
JSD # 2006.111.00 phase 06
Prepared for
AMB Property Corporation
San Francisco, California
JOB NAME:
Upland Distribution Center
Building 294
JOB NO:
2006.111.00
SHEET NO:
1
ENGINEER:
LW
DATE:
Apr -06
ANALYSIS:
Voluntary Seismic Retrofit
Building 294
1105 Andover Park West
Tukwila, Washington 98188
IBC Sec. 1615 Site Ground Motion
ZOO. Fein. Th06
3006 Nevt.41
'Gal lc
Latitude
Longitude =
Soil Profile Type (Class) _
Mapped Spectral Acceleration = Ss =
Mapped Spectral Acceleration = S =
Adjusted Mapped Spectral Acceleration = SMS =
Adjusted Mapped Spectral Acceleration = SMt =
Design Spectral Acceleration, SDS = 2S / 3 = 0.886 g
Design Spectral Acceleration, SDI = 25 / 3= 0.469 g
IBC Sec. 1616 Criteria Selection
2006.111.00 Upland Bldg 294- retroMISIte
Seismic Use Group =
Seismic Design Category =
Importance Factor = I = I =
2
1.00
Sec. 1616.2
Tables 1616.3(1) and (2)
Table 1604.5
JOB NAME:
Upland Distribution Center
Building 294
JOB NO:
2006.111.00
SHEET NO:
2
ENGINEER:
LW
DATE:
Apr-06
ANALYSIS:
Voluntary Seismic Retrofit
J.S. DYER & ASSOCIATES INC.
STRUCTURAL ENGINEERS
Roofing:
1/2" Plywood Sheathing:
Purlins: 4" x 16"(11.0 #/ft) @ 8' oc:
Girders: 6.75" x 31.5" GLB (51.7 #/ft) @ 24' oc
Mechanical / Electrical
Sprinklers:
Suspended Ceiling System:
Miscellaneous:
TOTAL:
2006.111.00 Upland Bldg 294-retrofit \ Roof 3
IBC Sec. 1607.11.2 Minimum Roof Live Load
For Flat Roofs
Roof Weight
Roof Loads
This spreadsheet calculates the roof loads for the Voluntary Seismic Retrofit of a one-story rigid wall / flexible
diaphragm structure in accordance with the 2003 International Building Code (IBC).
Purlins Girders
psf
psf
psf
psf
psf
psf
psf
psf
psf
Tributary Area (A.) Live Load
0 to 200 11 12
200 to 600 ft 1.2 - 0.001/4
over 600 ft 20
59.063
JOB NAME:
Upland Distribution Center
Building 294
JOB NO:
2006.111.00
SHEET NO:
•
ENGINEER:
LW
DATE:
Apr -06
ANALYSIS:
Voluntary Seismic Retrofit
Tributary Wall Weight
Allowable Stress Desi • Basis
2008.111.00 Upland Bldg 294 - retrofit \Walls 1 and 18 4
J.S. DYER & ASSOCIATES INC.
STRUCTURAL ENGINEERS
Wall Anchorage - Longitudinal Perimeter Walls (Walls 1 and 18)
This spreadsheet performs supporting calculations for out -of -plane wall anchorage for the Voluntary Seismic Retrofit
of a one -story rigid wall / flexible diaphragm structure in accordance with the 2003 International Building Code
Top -Of -Wall Elevation =h„ 4 ft
Average Diaphragm Elevation = h = 4, ft
Bottom -Of -Wall Elevation = h = ft
Wall Thickness = T = ; ,5 ` inch
Wall Unit Weight = W = " $ 45, .; pcf
Tributary Wall Height = H = 13.208 ft
Tributary Wall Weight = W = 1037 II/ft
IBC Sec. 1620.3.1 Anchorage Of Concrete Or Masonry Walls (Strength Design Basis)
Importance Factor = I = 1.00
Design Spectral Acceleration = Sp = 0.886
F = 280
F 0.10W 104
F = 0.8S = 735
F = 735
Anchor Spacing = s =
EASD = Fp/ 1.4=
F = sEnsD =
F =1.4F =
525
4333
6066
#/ft
#/ft
#/ft
#/ft
H = (b - h + 0.5(h +h
W TWH /
linked from Site
linked from Site
Sec. 1604.8.2
Sec. 1620.2.7
Eq. 16 -62
largest [FFp1, F p2. F
A
ft
#/ft
pounds
pounds
for non -steel elements
for steel elements
JOB NAME:
Upland Distribution Center
Building 294
JOB NO:
2006.111.00
SHEET NO:
I-1
ENGINEER:
LW
DATE:
Apr -06
ANALYSIS•
Voluntary Seismic Retrofit
2008.111.00 Upland Bldg 294- retrofit \Walls 1 and 18 5
J.S. DYER & ASSOCIATES INC.
STRUCTURAL ENGINEERS
Wall Anchorage - Longitudinal Perimeter Walls (Walls 1 and 18)
inches
inches
inches
pounds
2 pounds
2167 pounds
5071 pounds
22503 pounds
0.85 OK
0.27 OK
inches
pounds
0.3068 in
1627 pounds
2167 pounds
5550 pounds
8034 pounds
0.78 OK
0.76 OK
ICBO ER -5302, Table 2
ICBO ER -5302, Table 2
V, = 2(0.33F„)Arod
JOB NAME:
Upland Distribution Center
Building 294
JOB NO:
2006.111.00
SHEET NO:
5
ENGINEER:
LW
DATE:
Apr -06
ANALYSIS:
Voluntary Seismic Retrofit
Anchorage Design of Threaded Rods in Concrete Using HILT! HIT HY -150 Adhesive System
Based on ICBO ER -5193
Anchor Rod Data
Anchorage Purpose, b'ktp
3ongl .6410
Min Shear Toward Edge Distance, C=
Min Shear Not Toward Edge Distance, C=
Load Factors
Increase for Short-Term Loading, Inc =
Allowable Tension Loads from Table 6
Tension Capacity of Concrete,
Tension Capacity of Rod Steel,
Allowable Shear Loads from Table 7
Shear Capacity of Concrete,
Shear Capacity of Rod Steel,
Spacing Distance for Full Capacity,
Edge Distance for Full Capacity,
2006.111.00 Upland Bldg 294- retrofitll-lilti 1
J.S. DYER &ASSOCIATES INC.
STRUCTURAL ENGINEERS
d = 3/4 In
P s =
Vs =
Tc =
Ts =
Vc =
V s =
5.887
ASTM A36
in
in
Ibs
Ibs
f'c =MS psi
4,932 Ibs
8,455 Ibs
5,522 Ibs
4,355 Ibs
Edge Distance & Spacing for Full Capacity from Table 6
8.500 in
6.500 in
Reduction Factors from Table 4
Min Anchor Spacing Distance Factor, 0.250
Min Anchor Spacing Distance, 2.125 in
Min Anchor Edge Distance Factor, 0.330
Min Anchor Edge Distance, 2.145 in
Tension Capacity Reduction Factors
Based on Anchor Spacing, fn = 0.700
Based on Anchor Edge Distance, fn = 0.600
Shear Capacity Toward Edge Reduction Factors
Based on Anchor Spacing, fv = 0.700
Based on Anchor Edge Distance, fv = 0.200
Shear Capacity Not Toward Edge Reduction Factors
Based on Anchor Spacing, fv = 0.700
Based on Anchor Edge Distance, fv = 0.600
Calculated Reductions for Concrete Capacity
Tension Capacity Reduction
Based on Spacing, Rt1 =
Based on Edge Distance, Rt2 =
Reduction, Rt = Rt1 • Rt2 =
Shear Toward Edge Capacity Reduction
Based on Spacing, Ref =
Based on Edge Distance, Re2 =
Reduction, Re = Re1 • Re2 =
Shear Not Toward Edge Capacity Reduction
Based on Spacing, Rn1 =
Based on Edge Distance, Rn2 =
Reduction, Rn = Rn1 • Rn2 =
Adjusted Allowable Loads
Concrete Allowables
Tension, Ptc = Tc • Inc • Rt =
V Toward Edge, Vtc = Vc " Inc • Re =
V Not Toward Edge, Vnc = Vc • Inc " Rn =
Rod Steel Allowables
Tension,
Shear,
0.882
1.000
0.882
0.882
1.000
0.882
0.882
1.000
0.882
5,801 Ibs
6,494 Ibs
6,494 Ibs
Pts = Ts • Inc = 11,271 Ibs
Vts = Vs • Inc = 5,805 Ibs
Concrete Tension + Shear Toward Edge Interaction,
Uct = (Ps / Ptc) + (Vs / Vtc) = 0.373 OK
Concrete Tension + Shear Not Toward Edge Interaction,
Ucn = (Ps / Ptc) + (Vs / Vnc) = 0.373 OK
Rod Steel Tension + Shear Interaction,
Us = (Ps / Pts) + (Vs / Vts) = 0.037 OK
Concrete Thickness, Ut = t / e = 1.529 OK
JOB NAME:
Upland Distribution Center
Building 294
JOB NO:
2006.111.00
SHEET NO:
(,
ENGINEER:
LW
DATE:
Apr -06
ANALYSIS:
Voluntary Seismic Retrofit
Tributary Wall Weight
Wall Anchorage - Transverse Perimeter Walls (Walls A and F)
This spreadsheet performs supporting calculations for out -of -plane wall anchorage for the Voluntary Seismic Retrofit
of a one -story rigid wall / flexible diaphragm structure in accordance with the 2003 International Building Code
Top -Of -Wall Elevation = h„ =
Average Diaphragm Elevation = h =
Bottom -Of -Wall Elevation = N =
Wall Thickness = T =
Wall Unit Weight = W =
Tributary Wall Height = H =
Tributary Wall Weight = W =
J.S. DYER & ASSOCIATES INC.
STRUCTURAL ENGINEERS
ft
ft
inch
pcf
13.208 ft
1037 #/ft
IBC Sec. 16203.1 Anchorage Of Concrete Or Masonry Walls (Strength Design Basis)
Allowable Stress Desi • n Basis
Importance Factor = I = 1.00
Design Spectral Acceleration = SDS = 0.886
F = 280 #/ft
F = 0.10W = 104 #/ft
F = 0.8S = 735 #/ft
F = 735 #/ft
Anchor Spacing = s =
EAso Fp /
F = sE,.
F, =1.4F
2006.111.00 Upland Bldg 294- retroffi1Walls A and F 7
525
ft
#/ft
pounds
pounds
11 =(hwp - hp) +0.5(h„ +hn«)
W TWH /12
linked from Site
linked from Site
Sec. 1604.8.2
Sec. 1620.2.7
Eq. 16-62
largest [F Fp2. Fp3]
for non -steel elements
for steel elements
J.S. DYER ASSOCIATES INC.
r
JOB NAME: Upland Distribution Center JOB NO: 2006.111.00 i SHEET NO: 4-
Building 294 ENGINEER: LW (DATE: Apr -06
ANALYSIS: Voluntary Seismic Retrofit
w
Wall Anchorage Transverse Perimeter Walls (Walls A and F)
Continuity Tie At Wall Zone 4 Hardware
ar (2) CT/72 Paired Units Model
'y2
Number Of Bolts
2
Bolt Diameter=
S3t$ inches
as Rod Diameter
518
Number of Paired Assemblies N
1.
Wood Member Thickness
3� k/2 11 inches
ar Wood Capacity Each Pair V
°5 )1=', pounds
Steel Capacity Each Pair V,
22j pounds
Fred F 2N
2101 pounds
be
Total Wood Capacity NV F ivl�t
5071 pounds
Total Steel Capacity NV, F l (wl•
22503 pounds
r Wood Capacity Unity Check F Fw..d (wj w)
0.83 OK
Steel Capacity Unity Check F tal F. l (.0 w
0.26 OK
W
[a
au
1r+
SO
to
W
GO
ft
Continuity Tie At Wall Simpson Hardware
(2) Paired Units Model =Ai
Rod Strength F.
psi
Rod Diameter d
inches
Number Of Bolts
Bolt Diameter
inches
Number of Paired Assemblies N
Wood Member Thickness=
inches
Wood Capacity Each Pair V 50=s
pounds
Rod Area A,. 0.3068
i
Steel Capacity Each Pair V, 8034
pounds
F, F 2N 2101
pounds
Total Wood Capacity NV. Fwo d .u•w) 5550
pounds
Total Steel Capacity NV. F,�l is 8034
pounds
Wood Capacity Unity Check F F i,�l 0.76
OK
Steel Capacity Unity Check F F l wl•w) 0.73
OK
V, 2(0.33F.)A
2006.111.00 Upland Bldg 294retrofit \Walls A and F 8
r
ICBO ER -5302, Table 2
ICBO ER -5302, Table 2
J.S. DYER &ASSOCUTESINC.
JOB NAME: Upland Distribution Center JOB NO:
2006.111.00 (SHEET NO:
WIN
Building 294 ENGINEER: LW DATE:
Apr-06
ANALYSIS: Voluntary Seismic Retrofit
Anchorage Design of Threaded Rods in Concrete Using HILTI HIT HY-150 Adhesive System
Based on ICBO ER5193
Anchor Rod Data
Reduction Factors from Table 4
Anchorage Purpose,
Min Anchor Spacing Distance Factor,
0.250
Min Anchor Spacing Distance,
2.125 in
Min Anchor Edge Distance Factor,
0.330
sr
Threaded Rod Diameter, d 3/4 in
Min Anchor Edge Distance,
2.145 in
Embedment Depth, a In
Tension Capacity Reduction Factors
Concrete Thickness, t
Based on Anchor Spacing, fn
0.700
Based on Anchor Edge Distance, fn
0.600
Embedment to Diameter Ratio, 5.667
Shear Capacity Toward Fdae Reduction Factors
Based on Anchor Spacing, IV=
0.700
yy
Applied Service Tension Load, PS I bs
Based on Anchor Edge Distance, iv
0.200
Applied Service Shear Load, Vs lbs
Shear Canacitv Not Toward FdaA Reduction
Factors
Based on Anchor Spacing, tv
0.700
Concrete Compressive Strength, f c=nmpsi
Based on Anchor Edge Distance, tv
0.600
Rod Material, ASTIVI A36
Calculated Reductions for Concrete Capacity
yy
Min Anchor Spacing, s=MqWin
Tension Capacity Reduction
Based on Spacing, Rtl
0.882
Min Shear Toward Edge Distance, c =24zp in
Based on Edge Distance, Rt2
1.000
Min Shear Not Toward Edge Distance, c in
Reduction, Rt Rill Rt2
0.882
as
Shaer Toward Edae CaDacltv Reduction
Load Factors
Based on Spacing, Ref
0.882
Based on Edge Distance, Reg
1.000
60
Increase for Short-Term Loading, Inc
Reduction, Re Rat Re2
0.882
Shear Not Toward Fdae Capacity Reduction
Allowable Tension Loads from Table 6
Based on Spacing, Rot
0.882
Based on Edge Distance, Rn2
1.000
Tension Capacity of Concrete, Tc 4,932 lbs
Reduction, Rn Rnl Rn2
0.882
Tension Capacity of Rod Steel, Ts 8,455 lbs
Adjusted Allowable Loads
Allowable Shear Loads from Table 7
Concrete Allowahlas
Shear Capacity of Concrete. Vc 5,522 lbs
Tension, Pic Tc Inc Rt
5,801 lbs
Shear Capacity of Rod Steel, Vs 4,356 lbs
V Toward Edge, Vtc Vc Inc Re
6,494 lbs
err
V Not Toward Edge, Vnc= Vc' Inc' Rn=
6,494 lbs
Edge Distance Spacing for Full Capacity from Table 6
Rod Steel Allowables;
Spacing Distance for Full Capacity, 8.500 In
Tension, Pis =Ts* Inc=
11,271 lbs
as
Edge Distance for Full Capacity, 6.500 In
Shear, Vts Vs' Inc
5,805 lbs
Concrete Tension Shear Toward Edge Interaction,
Uct (Ps Ptc) (Vs Vtc)
0.362 OK
Concrete Tension Shear Not Toward Edge
Interaction,
Ucn (Ps Ptc) (Vs Vnc)
0.362 OK
Rod Steel Tension Shear Interaction,
so
US (Ps pt$) (VS VtS)
0.035 OK
Concrete Thickness, Ut t a
1.529 OK
2006.111.00 Upland Bldg 294-retrofit\Hilti 2
up
JOB NAME:
Upland Distribution Center
Building 294
JOB NO:
2006.111.00
SHEET NO:
q
ENGINEER:
LW
DATE:
Apr -06
ANALYSIS:
Wall Anchorage to Flexible Diaphragm, Rods
This spreadsheet performs supporting calculations for out -of -plane wall anchorage for the Voluntary Seismic Retrofit
of a one -story rigid wall / flexible diaphragm structure in accordance with the 2003 International Building Code
Tributary Wall Weight
Allowable Stress Design Basis
Steel Anchor Road Design
Top -Of -Wall Elevation = h =
Average Diaphragm Elevation = h =
Bottom -Of -Wall Elevation = h =
Wall Thickness = T =
Wall Unit Weight = W =
Tributary Wall Height = H =
Tributary Wall Weight = W =
J.S. DYER & ASSOCIATES INC.
STRUCTURAL ENGINEERS
Wall Anchorage - Steel Anchor Rod
IBC Sec. 1620.3.1 Anchorage Of Concrete Or Masonry Walls (Strength Design Basis)
Importance Factor = I = 1.00
Design Spectral Acceleration = S = 0.886
F
Fp2 = 0.10W =
Fp3 = 0.8SDSIEW =
F =
Anchor Spacing = s =
EASD= Fp /
F = sEAso
F,u„ = 1.4F
Anchor Road Material =
Yield Strength, Fy =
Ultimate Tensile Strength, Fu =
Rod Diameter =
Gross Area of Rod, Ag =
Net Tensile Area of Road, An =
Allowable Stress Increase =
Rod Tension Capacity: Yield Stress, T =
Rod Tension Capacity: Ultimate Tensile Stress, T =
Wall Anchorage Demand, F, 1=
Rod Tension Capcity, T =
Steel Capacity Unity Check = Fu„, / Fowl (,howl =
2006.111.00 Upland Bldg 294- retrofltRods 10
:-£ ft
:rft
inch
pcf
13.208 ft
1037 #/ft
280
104
735
735
#/ft
#/ft
#/ft
#/ft
USA ft
525 #/ft
pounds
pounds
ASTM A36
36 ksi
58 ksi
inches
0.442
in
0.334 in
1.33
12.692 k
12.900 k
6.066 k
12.692 k
0.48 OK
H= (N - h„) +0.5(hp +h
W TWH /12
linked from Site
linked from Site
Sec. 1604.8.2
Sec. 1620.2.7
Eq. 16 -62
largest [F F F
for non -steel elements
for steel elements
JOB NAME:
Upland Distribution Center
Building 294
JOB NO:
2006.111.00
SHEET NO:
I C7 -
ENGINEER:
LW
DATE:
Apr -06
ANALYSIS:
Wall Anchorage to Flexible Diaphragm, Rods
Anchorage Design of Threaded Rods in Concrete Using HILTI HIT HY -150 Adhesive System
Based on ICBO ER -5193
Anchor Rod Data
Embedment Depth,
Concrete Thickness,
Embedment to Diameter Ratio,
Applied Service Tension Load,
Applied Service Shear Load,
Concrete Compressive Strength,
Rod Material,
Min Anchor Spacing,
Min Shear Toward Edge Distance,
Min Shear Not Toward Edge Distance,
Load Factors
Allowable Tension Loads from Table 8
Tension Capacity of Concrete,
Tension Capacity of Rod Steel,
Allowable Shear Loads from Table 7
Shear Capacity of Concrete,
Shear Capacity of Rod Steel,
Spacing Distance for Full Capacity,
Edge Distance for Full Capacity,
J.S. DYER & ASSOCIATES INC.
STRUCTURAL ENGINEERS
Increase for Short-Term Loading, Inc =
d = 3/4 In
Ps =h :` 33
Vs =, ::.:.:.......
f'c=
5=
C=
Tc =
Ts =
V c =
Vs =
Edge Distance & Spacing for Full Capacity from Table 6
2006.111.00 Upland Bldg 294- retrofit\Hilti 3
5.667
a psi
ASTM A36
4,932 Ibs
8,455 Ibs
Concrete Allowables
5,522 Ibs Tension, Ptc = Tc • Inc • Rt = 5,801 Ibs
4,355 Ibs V Toward Edge, Vtc = Vc • Inc • Re = 6,494 Ibs
V Not Toward Edge, Vnc = Vc • Inc • Rn = 6,494 Ibs
8.500 in
Ibs
Ibs
6.500 in
Reduction Factors from Table 4
Min Anchor Spacing Distance Factor, 0.250
Min Anchor Spacing Distance, 2.125 in
Min Anchor Edge Distance Factor, 0.330
Min Anchor Edge Distance, 2.145 in
Tension Capacity Reduction Factors
Based on Anchor Spacing, fn = 0.700
Based on Anchor Edge Distance, fn = 0.600
Shear Capacity Toward Edge Reduction Factors
Based on Anchor Spacing, fV = 0.700
Based on Anchor Edge Distance, fv = 0.200
Shear Capacity Not Toward Edge Reduction Factors
Based on Anchor Spacing, fv = 0.700
Based on Anchor Edge Distance, fv = 0.600
Calculated Reductions for Concrete Capacity
Tension Capacity Reduction
Based on Spacing, Rt1 =
Based on Edge Distance, Rt2 =
Reduction, Rt = Rt1 • Rt2 =
Shear Toward Edge Capacity Reduction
Based on Spacing, Re1 =
Based on Edge Distance, Re2 =
Reduction, Re = Re1 • Re2 =
Shear Not Toward Edge Capacity Reduction
Based on Spacing, Rn1 =
Based on Edge Distance, Rn2 =
Reduction, Rn = Rn1 • Rn2 =
Adjusted Allowable Loads
pod Steel Allowables
Tension,
Shear,
0.882
1.000
0.882
0.882
1.000
0.882
0.882
1.000
0.882
Pts = Ts • Inc = 11,271 Ibs
Vts = Vs " Inc = 5,805 Ibs
Concrete Tension + Shear Toward Edge interaction,
Uct = (Ps / Ptc) + (Vs / Vtc) = 0.747 OK
Concrete Tension + Shear Not Toward Edge Interaction,
Ucn = (Ps / Ptc) + (Vs / Vnc) = 0.747 OK
Rod Steel Tension + Shear Interaction,
Us = (Ps / Pts) + (Vs / Vts) = 0.148 OK
Concrete Thickness, Ut = t / e = 1.529 OK
JOB NAME:
Upland Distribution Center
Building 294
JOB NO:
2006.111.00
SHEET NO: I
ENGINEER:
LW
DATE:
Apr -06
ANALYSIS:
Diaphragm Analysis
J.S. DYER & ASSOCIATES INC.
ASCE 7 Sec. 93.5 Equivalent Lateral Force Procedure
Basic Seismic Force -
Resisting System
Response Modification Coefficient = R =
System Overstrength Factor = t2 =
C =
redundancy factor = p =
T= C,(hn) /
C,= SDS /(R/I)=
Cs(maz) = SDI / T( _
Cs(minl) = 0.044S1351I =
Cs(min- SDC E or n = 0 . 5 S1 / (RiI) =
;Tailo
IBC Sec. 1620.4.3 Diaphragms
Seismic Lateral Loads For Diaphragm Design
2006.111.00 Upland Bldg 294- retrofit1Diaphragm
STRUCTURAL ENGINEERS
Diaphragms
This spreadsheet summarizes the development of anchorage loads into the diaphragm for the Voluntary Seismic
„ Retrofit of a one -story rigid wall / flexible diaphragm structure in accordance with the 2003 International Building
IBC Sec. 1617.4 requires that the Equivalent Lateral Force Procedure of ASCE 7
Soil Profile Type (Class) = D
Mapped Spectral Acceleration = S = 0.457
Design Spectral Acceleration = S = 0.886
Importance Factor = I = 1.00
Average Diaphragm Elevation = h = 1'L4` ft
Transverse Lon 'tudinal
c,=
F =C,W
Fp(max) = 0.4S =
Fp(min) = 0.2S =
F =
Fpp)= F /1.4=
0.23
0.222
0.950
0.039
0.000
0.039
0.222
I Transverse
0.222
0.354
0.177
0.222
0.158
Longitudinal
0.222
0.354
0.177
0.222
0.158
I Transverse
Tributary Wall Weight = W,, =
Roof Length = L =
Roof Unit Weight = U =
Roof Weight = LU = W ter 1374
Total Weight = 2W,, W Wp = 3448
Roof Seismic Load = F p(MD) W p = V ,,nr = 546
12
g
g
0.23 seconds
0.222
0.950
0.039
0.000
0.039
0.222
wp
Wp
wp
wp
Wp
Longitudinal
#/ft
ft
psf
9561 #/ft
11635 #/ft
1841 #/ft
-02, Sec. 9.5.5 be used.
linked from Site
linked from Site
linked from Site
linked from Site
Table 9.5.2.2
Table 9.5.2.2, footnote g
Table 9.5.5.3.2
code interpretation for diaphragms
Eq. 9.5.5.3.2 -1
Eq. 9.5.5.2 -1.1
Eq. 9.5.5.2 -1.2
Eq. 9.5.5.2 -1.3
Eq. 9.5.5.2 -1.4
Cx(min) = larger [Cs(minlh Cox E or nj
C s(min) < Cs < C s(max)
Eq. 16 -63
Fp(min) < F <
previously calculated
previously calculated
JOB NAME:
Upland Distribution Center
Building 294
JOB NO:
2006.111.00
SHEET NO:
12_.
ENGINEER:
LW
DATE:
Apr -06
ANALYSIS:
Diaphragm Analysis
34418
3969
v.x = VWx /W
DIAPHRAGM SHFARS
Ms.x = V.00.L /8
.lidffi thTi MWx /W
CHORD FORCES
J.S. DYER & ASSOCIATES INC.
STRUCTURAL ENGINEERS
Vmur=
L
W =
Vmu=
V max =
Mmax =
T rim =
vmof =
L =
W=
Vm„ _
Vm.x =
Mm.% _
=
2006.111.00 Upland Bldg 294- retrofitDlaphragm 13
22782
712
140966
4405
6552
305
39312
1828
#/ft Seismic Lateral Load
ft Diaphragm Length
ft Diaphragm Depth
pounds Maximum Shear
#/ft Maximum Shear
ft-# Maximum Moment
pounds Maximum Chord Force
#/ft Seismic Lateral Load
ft Diaphragm Length
ft Diaphragm Depth
pounds Maximum Shear
#/ft Maximum Shear
ft-# Maximum Moment
pounds Maximum Chord Force
JOB NAME:
Upland Distribution Center
Building 294
JOB NO:
2006.111.00
SHEET NO:
r2.
ENGINEER:
LW
DATE:
Apr-06
ANALYSIS•
Diaphragm Continuity Ties
This spreadsheet performs supporting calculations for continuity ties for the Voluntary Seismic Retrofit of a one -story
Number Subdiaphragms = N =
Edge Reaction = V = [i43$2 } pounds previously calculated
F = NV = 16162 pounds strength level
2006.111.00 Upland Bldg 294-retrofit \Tie (NS) 14
J.S. DYER & ASSOCIATES INC.
STRUCTURAL ENGINEERS
Dead = D - 'k0 psf roof dead load
Live L = 100 !psf roof live load
Area A = ,1 42, ft area tributary to tie
F = 0.05(D+L)A = 12149 pounds strength level
previously calculated
strength level
F = 12149 pounds
F = 14316 pounds
F = 6075 pounds
F = 25666 pounds
F = 16162 pounds
F = 25666 pounds largest [F F F F F
F = F / 1.4 = 18333 pounds ASD Basis for non -steel elements
Fps =1.4F = 25666 pounds for steel elements
JOB NAME:
Upland Distribution Center
Building 294
JOB NO:
2006.111.00
SHEET NO: 14
ENGINEER:
LW
DATE:
Apr -06
ANALYSIS•
Diaphragm Continuity Ties
Steel Capacity Each Pair = V, =
F =F/ 2N =
Total Wood Capacity = NV = Fwood (glow) =
Total Steel Capacity = NV, = F,eg (glow) _
Wood Capacity Unity Check = F / F (,,l =
Steel Capacity Unity Check = F, / F ated (gl =
Continuity Tie At Wall - Zone 4 Hardware
(2) CT/f2 Paired Units - Model =
Number Of Bolts =
Bolt Diameter =
Rod Diameter =
Number of Paired Assemblies = N =
Wood Member Thickness =
Wood Capacity Each Pair = V =
Steel Capacity Each Pair = V, =
F =F/ 2N =
Total Wood Capacity = NV,„ = F ( =
Total Steel Capacity = NV, = F (am) =
Wood Capacity Unity Check = F / Fwood (glow) =
Steel Capacity Unity Check = F, / F, (,st =
Continuity Tie At Wall - Simpson Hardware
2006.111.00 Upland Bldg 294- retrofitTle (NS) 15
J.S. DYER & ASSOCIATES INC.
STRUCTURAL ENGINEERS
Continuity Ties - Longitudinal Direction (NS Forces)
9166
19551
39966
0.94
0.64
0.7854
27200
9166
22160
27200
0.83
0.94
inches
inches
inches
pounds
pounds
pounds
pounds
pounds
OK
OK
psi
inches
inches
inches
pounds
in'
pounds
pounds
pounds
pounds
OK
OK
ov
1410!
•11..
IMIONBIGNet
Mt MAIRIIMINI
11aoo.uewa•
emeanrera11a •
�wtiw11
. !IIIIIMEIS
a Mitt •v :� Ywwee11areo
ICBO ER -5302, Table 2
ICBO ER -5302, Table 2
V, = 2(0.33FJArod
JOB NAME:
Upland Distribution Center
Buiding 294
JOB NO:
2006.111.00
SHEET NO: LS
ENGINEER:
LW
DATE:
Apr -06
ANALYSIS:
Diaphragm Continuity Ties
F = 0.05% = 873 pounds Eq. 16-59
Wall Anchorage Force = F = #/ft
Tie Spacing = s = ft
F = F = 24888 pounds
Subdiaphragm Force
Number Subdiaphragms = N =
Edge Reaction = Vmuc = pounds previously calculated
Fp3 =NVmu = 6612 pounds strength level
F =
F =
Fp3 =
F =
Fps =
F =
F= F /1.4
F ace] =1.4F =
1746 pounds
2057 pounds
873 pounds
24888 pounds
6612 pounds
24888 pounds
pounds
pounds
17777
24888
ASD Basis
roof dead load
roof live load
area tributary to tie
strength level
previously calculated
strength level
largest [F F F F F
for non -steel elements
for steel elements
JOB NAME:
Upland Distribution Center
Buiding 294
JOB NO:
2006.111.00
SHEET NO:
ENGINEER:
LW
DATE:
Apr-06
ANALYSIS:
Diaphragm Continuity Ties
J.S. DYER & ASSOCIATES INC.
STRUCTURAL ENGINEERS
Continuity Tie At Wall - Zone 4 Hardware
(2) CT/T2 Paired Units - Model =
Number Of Bolts =
Bolt Diameter =
Rod Diameter =
Number of Paired Assemblies = N =
Wood Member Thickness =
Wood Capacity Each Pair = V =
Steel Capacity Each Pair = V, =
F rod = P1 2N =
Total Wood Capacity = NV = F (atlow) =
Total Steel Capacity = NV, = F
Wood Capacity Unity Check = F / Fwood (snow)
Steel Capacity Unity Check = F / F (a1 =
Continuity Tie At Wall - Simpson Hardware
(2) Paired Units - Model =
Rod Strength = =
Rod Diameter = d, =
Number Of Bolts =
Bolt Diameter =
Number of Paired Assemblies = N =
Wood Member Thickness =
Wood Capacity Each Pair = V =
Rod Area = A
Steel Capacity Each Pair = V, =
F = F / 2N =
Total Wood Capacity = NV = F„, w =
Total Steel Capacity = NV, = End mow)
Wood Capacity Unity Check = F / F„ ( =
Steel Capacity Unity Check = F / F eed (dm) =
2006.111.00 Upland Bldg 294-retrofitMe (EW)
Continuity Ties - Transverse Direction (EW Forces)
17
w g:71
4
inches
1 inches
inches
pounds
pounds
8889 pounds
23322
39966
0.76
0.62
pounds
pounds
OK
OK
inches
inches
pounds
0.7854 in
27200 pounds
8889 pounds
22160 pounds
27200 pounds
0.80 OK
0.92 OK
ICBO ER-5302, Table 2
ICBO ER-5302, Table 2
V, = 2(0.33FuVirod
ACTIVITY NUMBER: D06 -203
PROJECT NAME: BUILDING 294
SITE ADDRESS: 1105 ANDOVER PK W
X Original Plan Submittal
Response to Correction Letter #
DATE: 05 -31 -06
Response to Incomplete Letter #
Revision # After Permit Issued
DEPARTMENTS: �Or/
Billi L &
ng Division
Pu2 if,,Workk
DETERMINATION OF COMPLETENESS: (Tues., Thurs.)
Complete
Comments:
Permit Center Use Only
INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED:
Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials:
TUES/THURS ROUTING:
Please Route E Structural Review Required
REVIEWER'S INITIALS:
APPROVALS OR CORRECTIONS:
Approved ❑
Notation:
REVIEWER'S INITIALS:
Documentilrouling slip.doc
2 -2802
PERMIT COORD COPY
PLAN REVIEW /ROUTING SLIP
5tl c,
Fire Prevention
Structural
Incomplete ❑
Approved with Conditions
DATE:
DATE:
i5m RIA to--1
Planning Division
Permit Coordinator
No further Review Required
DUE DATE: 06-06-06
Not Applicable ❑
DUE DATE: 07-04-06
Not Approved (attach comments) ❑
Permit Center Use Only
CORRECTION LETTER MAILED:
Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials:
License Information
License
SAUNDCI953ND
Licensee Name
SAUNDERS CONSTRUCTION INC
Licensee Type
CONSTRUCTION CONTRACTOR
UBI
602518261
Ind. Ins. Account Id
PRESIDENT
Business Type
CORPORATION
Address 1
1760 MONROVIA AVE UNIT A -1
Address 2
City
COSTA MESA
County
OUT OF STATE
State
CA
Zip
92627
Phone
9496460034
Status
ACTIVE
Specialty 1
GENERAL
Specialty 2
UNUSED
Effective Date
8/4/2005
Expiration Date
8/4/2007
Suspend Date
Separation Date
Parent Company
Previous License
Next License
Associated License
Business Owner Information
Name
Role
Effective Date
Expiration Date
CASILLAS, PATRICIA
AGENT
08/04/2005
SAUNDERS, STEVEN
PRESIDENT
08/04/2005
HILL, SUSAN
SECRETARY
08/04/2005
Look Up a Contractor, Electrician or Plumber License Detail Page 1 of 2
Washington State Department of Labor and Industries
General/Specialty Contractor
A business registered as a construction contractor with L &I to perform
construction work within the scope of its specialty. A General or Specialty
construction Contractor must maintain a surety bond or assignment of
account and carry general liability insurance.
Bond Information
Bond
Bond
Company
Name
Bond
Account
Number
Effective
Date
Expiration
Date
Cancel
Date
Impaired
Date
Bond
Amount
Received
Date
DEVELOPERS
SURETY &
Until
https: // fortress .wa.gov /lni/bbip /printer.aspx ?License= SAUNDCI953ND 07/06/2006
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x