Loading...
HomeMy WebLinkAboutPermit D06-207 - Industrial Caster - OfficeINDUSTRIAL CASTER CO 1085 ANDOVER PK E D06 -207 City Or' Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 - 431 -3665 Web site: ci.tukwila.wa.us Tenant: Name: INDUSTRIAL CASTER, CO Address* 1085 ANDOVER PK E, TUKW ILA WA DEVELOPMENT PERMIT Parcel No.: 2623049106 Permit Number: D06 -207 Address' 1085 ANDOVER PK E TUKW Issue Date: 08/07/2006 Suite No: Permit Expires On: 02/03/2007 Owner: Name: SECURITY CAPITAL INDUSTRIAL Address' C/O DELOITTE & TOUCHE LLP, 2235 FARADAY AVE STE 0, CARLSBAD CA 92008 Phone: Contact Person: Name: JULIE CHAN Address: 23215 66 AV S, KENT WA, 98032 Phone: 253- 520 -0244 Contractor: Name: SIERRA CONSTRUCTION CO INC. Address: 19900 144TH AVENUE NE, WOODINVILLE WA 98072 Phone: (425)487 -5200 Contractor License No: SIERRCC145N8 DESCRIPTION OF WORK: SMALL INTERIOR TENANT IMPROVEMENT TO RE -WORK LOCATION OF ONE OFFICE Value of Construction: $15,000.00 Fees Collected: $518.28 Type of Fire Protection: SPRINKLERS International Building Code Edition: 2003 Type of Construction: IIIB Occupancy per IBC: 0008 doc: IBC - PERMIT "continued on next page ** Expiration Date: 03/31/2008 Steven M. Mullet, Mayor Steve Lancaster, Director D06 -207 Printed: 08 -07 -2006 Public Works Activities: Channelization / Striping: N Curb Cut / Access / Sidewalk / CSS: N Permit Center Authorized Signature: Signature: Print Name: doc: IBC - PERMIT City old Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: ci.tukwila.wa.us Fire Loop Hydrant: N Number: 0 Size (Inches): 0 Flood Control Zone: N Hauling: N Start Time: End Time: Land Altering: N Volumes: Cut 0 c.y. Fill 0 c.y. Landscape Irrigation: N Moving Oversize Load: N Start Time: End Time: Sanitary Side Sewer: N Sewer Main Extension: N Private: Public: Storm Drainage: N Street Use: N Profit: N Non- Profit: N Water Main Extension: N Private: Public: Water Meter: N J OR, i • c C- C1-- Steven M. Mullet, Mayor Steve Lancaster, Director Permit Number: DO6 -207 Issue Date: 08/07/2006 Permit Expires On: 02/03/2007 Date: -1-t6 I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or Otte performance of work. I am authorized to sign and obtain this development permit. 3 / /oto Date: This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last Inspection. D06 -207 Printed: 08-07 -2006 CITY OF TUKWItLA DEPT. OF COQ, :1UNITY DEVELOPMENT 6300 CGUTFICENTER BLVD. TUKWILA, WA 98188 1: ***BUILDING DEPARTMENT CONDITIONS*** PERMIT CONDITIONS PERMIT CENTER Parcel No.: 2623049106 Permit Number: D06 -207 Address 1085 ANDOVER PK E TUKW Status: ISSUED Suite No: Applied Date: 06/05/2006 Tenant: INDUSTRIAL CASTER, CO Issue Date: 08/07/2006 2: No changes shall be made to the approved plans unless approved by the design professional in responsible charge and the Building Official. 3: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center (206/431- 3670). 4: All permits, inspection records, and approved plans shall be at the job site and available to the inspectors prior to start of any construction. These documents shall be maintained and made available until final inspection approval is granted. 5: New suspended ceiling grid and light fixture installations shall meet the non - building structures seismic design requirements of ASCE 7. 6: Partition walls that are tied to the ceiling and all partitions greater than 6 feet in height shall be laterally braced to the building structure. 7: All construction shall be done in conformance with the approved plans and the requirements of the International Building Code or International Residential Code, International Mechanical Code, Washington State Energy Code. 8: Ventilation is required for all new rooms and spaces of new or existing buildings and shall be in conformance with the International Building Code and the Washington State Ventilation and Indoor Air Quality Code. 9: All electrical work shall be inspected and approved under a separate permit issued by the Washington State Department of Labor and Industries (206/248- 6630). 10: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. 11: ' "'FIRE DEPARTMENT CONDITIONS * ** 12: The attached set of building plans have been reviewed by the Fire Prevention Bureau and are acceptable with the following concerns: 13: The total number of fire extinguishers required for a light hazard occupancy with Class A fire hazards is calculated at one extinguisher for each 3,000 sq. ft. of area. The extinguisher(s) should be of the "all purpose" (2A, 10 B:C) dry chemical type. The travel distance to any extinguisher must be 75' or less (IFC 906.3) (NFPA 10, 3 -2.1) 14: The total number of fire extinguishers required for an ordinary hazard occupancy with Class A fire hazards is calculated at one extinguisher for each 1,500 sq. ft. of area. The extinguisher(s) should be of the "All Purpose" (2A, 20B:C) dry chemical type. Travel distance to any fire extinguisher must be 75' or less. (IFC 906.3) (NFPA 10, 3 -2.1) doc: Conditions 006 -207 Printed: 08 -07 -2006 15: Portable fire extinguishers, not housed in cabinets, shall be installed on the hangers or brackets supplied. Hangers or brackets shall be securely anchored to the mounting surface in accordance with the manufacturer's installation instructions. Portable fire extinguishers having a gross weight not exceeding 40 pounds (18 kg) shall be installed so that its top is not more than 5 feet (1524 mm) above the floor. Hand -held portable fire extinguishers having a gross weight exceeding 40 pounds (18 kg) shall be installed so that its top is not more than 3.5 feet (1067 mm) above the floor. The clearance between the floor and the bottom of the installed hand -held extinguishers shall not be less than 4 inches (102 mm). (IFC 906.7 and IFC 906.9) 16: Fire extinguishers shall not be obstructed or obscured from view. In rooms or areas in which visual obstruction cannot be completely avoided, means shall be provided to indicate the locations of the extinguishers. (IFC 906.6) 17: Extinguishers shall be located in conspicuous locations where they will be readily accessible and immediately available for use. These locations shall be along normal paths of travel, unless the fire code official determines that the hazard posed indicates the need for placement away from normal paths of travel. (IFC 906.5) 18: Fire extinguishers require monthly and yearly inspections. They must have a tag or label securely attached that indicates the month and year that the inspection was performed and shall identify the company or person performing the service. Every six years stored pressure extinguishers shall be emptied and subjected to the applicable recharge procedures. If the required monthly and yearly inspections of the fire extinguisher(s) are not accomplished or the inspection tag is not completed, a reputable fire extinguisher service company will be required to conduct these required surveys. (NFPA 10, 4 -3, 4-4) 19: Egress doors shall be readily openable from the egress side without the use of a key or special knowledge or effort. (IFC 1008.1.8.3 subsection 2.2) 20: Dead bolts are not allowed on auxiliary exit doors unless the dead bolt is automatically retracted when the door handle is engaged from inside the tenant space. (IFC Chapter 10) 21: Door handles, pulls, latches, locks and other operating devices on doors required to be accessible by Chapter 11 of the International Building Code shall not require tight grasping, tight pinching or twisting of the wrist to operate. (IFC 1008.1.8.1) 22: Exit hardware and marking shall meet the requirements of the International Fire Code. (IFC Chapter 10) 23: Maintain sprinkler coverage per N.F.P.A. 13. Addition /relocation of walls, closets or partitions may require relocating and /or adding sprinkler heads. (IFC 901.4) 24: Sprinklers shall be installed under fixed obstructions over 4 feet (1.2 m) wide such as ducts, decks, open grate flooring, cutting tables, shelves and overhead doors. (NFPA 13- 8.6.5.3.3) 25: All new sprinkler systems and all modifications to existing sprinkler systems shall have fire department review and approval of drawings prior to installation or modification. New sprinkler systems and all modifications to sprinkler systems involving more than 50 heads shall have the written approval of the W.S.R.B., Factory Mutual, Industrial Risk Insurers Kemper or any other representative designated and /or recognized by the City of Tukwila, prior to submittal to the Tukwila Fire Prevention Bureau. No sprinkler work shall commence without approved drawings. (City Ordinance #2050) 26: Contact The Tukwila Fire Prevention Bureau to witness all required inspections and tests. (City Ordinances #2050 and #2051) 27: Any overlooked hazardous condition and /or violation of the adopted Fire or Building Codes does not imply approval of such condition or violation. 28: These plans were reviewed by Inspector 511. If you have any questions, please call Tukwila Fire Prevention Bureau at doc: Conditions D06 -207 Printed: 08 -07.2006 (206)575 -4407. 29: ***PUBLIC WORKS DEPARTMENT CONDITIONS*** ' 30: Applicant shall apply for a separate Construction Type C permit or submit a revision to this Tenant Improvement permit for installation of domestic water Reduced Pressure Princ. Assembly, DDCVA on fire protection service and irrigation Water Meter upgrade. These backflow deficiencies shall be in place by October 1, 2006 per July 31,2006 letter from Julie Chan, Prologis property Manager Q 253 520 -0244 addressed to Public Works. doc: Conditions "continued on next page" 008 -207 Printed: 08 -07 -2006 I hereby certify that I have read these conditions and will comply with them as outlined. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provision of any other work or local laws regulating construction or the performance of work. Signature: Print Name: doe: Conditions ,77 -i/ c CAa Date: 8- 7 -tom D06.207 Printed: 08 -07 -2006 Mailing Address: CITY OF TUKWILA Community Development Department Public Works Department Permit Center 6300 SouthcenterBlvd., Suite 100 Tukwila, WA 98188 httal/www.ci.tukwilawa.us Name: Vv Ike. cran Mailing Address: a:32AS (&$v AVG S E -Mail Address: tha n Pf IoCetS • C A v n ENGINEER OF RECORD - All plans must be wet stamped by Engineer of Record Qp'Applicationswmme- Applic.liom On Lind - 2006 - Petmit Appiic.don.doc Revised: 4-2006 bit Building Permit No. Pb(p - 1-01 - Mechanical Permit No. Plumbing/Gas Permit No. Public Works Permit No. Project No. (For office use only) Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. * *Please Print** SHE LOCATION /� J n �K King Co Assessor's Tax No.: Q (a 2 3o c1 -1 100 Site Address: I b8 ' PVVnCLO1/12.Y rQ ,9(- Suite Number: Floor: Tenant Name: Ivld.ust1na1 r osier t l ,O New Tenant: t tg Yes ❑..No Property Owners Name: PeU LA (CIS ZS21S ( etilll Ave. Sam Y City WA State State 460321 Zip CONTACT PERSON Day Telephone:. 53 - 520 - 0244 1'cvi - ' WA `l ?1032. City State Zip Fax Number: r�S'& 6 ' (RoG I GENERAL CONTRACTOR INFORMATION — (Contractor Information for Mechanical (pg 4) for Plumbing and Gas Piping (pg 5) ) Company Name: Mailing Address: City Contact Person: Day Telephone: E -Mail Address: Fax Number: Contractor Registration Number: Expiration Date: Zip ARCHITECT OF RECORD - All plans must be wet stamped by Architect of Record Company Name: C tkk4 Pea91 i` r— Mailing Address: Mil— F\ &k Ave, sit 1 ^43 'cak„c \AA Qolbl �� N ry� �+ City State Zip ts t r �, Contact Person: i �{'' • \ f 1GY Day Telephone: Orb — 770 -- RCA m 4- E -Mail Address: i,r11 .tt. r ! �_S bap- 7701 841 Company Name: Mailing Address: 0/ Pc City State Zip Contact Person: Day Telephone: E -Mail Address: Fax Number: Page 1 of 6 BUILDING PERMIT INFORMATION - 206 -431 -3670 Valuation of Project (contractor's bid price): $ �5 ( 1'ij Existing g Va uation: $ Scope of Work (please provide detailed information): funds kattlibr Tenant tnelp met- TD -worke ttcaknsn tc- tsne ofkc.a_. Will there be new rack storage? ❑..Yes ❑...No (If yes, a separate permit and plan submittal will be required) Provide All Building Areas in Square Footage Below PLANNING DIVISION: Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) *For an Accessory dwelling, provide the following: Lot Area (sq ft): Floor area of principal dwelling: Floor area for accessory dwelling: 'Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard: Compact: Handicap: Will there be a change in use? ❑ ....Yes ❑ ..No If "yes ", explain: FIRE PROTECTION/HAZARDOUS MATERIALS: '.Sprinklers ❑..Automatic Fire Alarm ❑..None ❑..Other(specify) Will there be storage or use of flammable, combustible or hazardous materials in the building? ❑.. Yes No If yes ", attach list of materials and storage locations on a separate 8 -1/2 x 11 paper indicating quantities and Material afety Data Sheets. SEPTIC SYSTEM: ❑ On -site Septic System — For on -site septic system, provide 2 copies of a current septic design approved by King County Health Department. Q:IAlplialions\Fosnts- Applications On LnsV- 2006 - Permit Appliation.doc Revised: 4-2006 bb Page 2 of 6 Existing Interior Remodel Addition to Existing Structure New Type of Construction per IBC Type of Occupancy per IBC 1 "Floor 0.91/4, 11) JKnt. in, Q '3 /s -t T Floor 3' Floor Floors thru Basement Accessory Structure* Attached Garage Detached Garage Attached Carport Detached Carport Covered Deck Uncovered Deck BUILDING PERMIT INFORMATION - 206 -431 -3670 Valuation of Project (contractor's bid price): $ �5 ( 1'ij Existing g Va uation: $ Scope of Work (please provide detailed information): funds kattlibr Tenant tnelp met- TD -worke ttcaknsn tc- tsne ofkc.a_. Will there be new rack storage? ❑..Yes ❑...No (If yes, a separate permit and plan submittal will be required) Provide All Building Areas in Square Footage Below PLANNING DIVISION: Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) *For an Accessory dwelling, provide the following: Lot Area (sq ft): Floor area of principal dwelling: Floor area for accessory dwelling: 'Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard: Compact: Handicap: Will there be a change in use? ❑ ....Yes ❑ ..No If "yes ", explain: FIRE PROTECTION/HAZARDOUS MATERIALS: '.Sprinklers ❑..Automatic Fire Alarm ❑..None ❑..Other(specify) Will there be storage or use of flammable, combustible or hazardous materials in the building? ❑.. Yes No If yes ", attach list of materials and storage locations on a separate 8 -1/2 x 11 paper indicating quantities and Material afety Data Sheets. SEPTIC SYSTEM: ❑ On -site Septic System — For on -site septic system, provide 2 copies of a current septic design approved by King County Health Department. Q:IAlplialions\Fosnts- Applications On LnsV- 2006 - Permit Appliation.doc Revised: 4-2006 bb Page 2 of 6 F P - U13LIC WORKS PERMIT INFORMATION - 206 -433 -0179 Scope of Work (please provide detailed information): Water District ._Tukwila ❑...Water District #125 ❑ ...Water Availability Provided Sewer District ❑...Tukwila ❑ ...Sewer Use Certificate Submitted with Application (mark boxes which apply): ID ...Civil Plans (Maximum Paper Size — 22" x 34 ") ❑ ...Technical Information Report (Storm Drainage) ❑ ...Bond ❑ .. Insurance ❑ .. Easement(s) Pr posed Activities (mark boxes that apply): ...Right-of-way Use - Nonprofit for less than 72 hours ❑ ...Right-of-way Use - No Disturbance ❑ ...Construction/Excavation/Fill - Right -of -way Non Right-of-way ❑ ...Total Cut ❑ ...Total Fill ❑... ValVue 0... Sewer Availability Provided Please refer to Public Works Bulletin #1 for fees and estimate sheet. cubic yards cubic yards ❑...Sanitary Side Sewer ❑ ...Cap or Remove Utilities ❑ ...Frontage Improvements ❑ ...Traffic Control ❑ ...Backflow Prevention - Fire Protection Irrigation Domestic Water ❑...Permanent Water Meter Size... f ❑ ...Temporary Water Meter Size .. t ❑ ...Water Only Meter Size ❑ ...Sewer Main Extension Public _ ❑...Water Main Extension Public Sy Q: Applicationaomu- Applicatioos On tirc3-2006 - Permit Applianon4a Revised: 4 -2006 bb Call before you Dig: 1 .. Abandon Septic Tank .. Curb Cut .. Pavement Cut .. Looped Fire Line Private Private ❑ .. Highline 0 .. Renton ❑ .. Renton ❑ .. Seattle ❑ .. Approved Septic Plans Provided ❑ .. Geotechnical Report ❑ .. Maintenance Agreement(s) ❑ .. Right-of-way Use - Profit for less than 72 hours ❑ .. Right-of-way Use — Potential Disturbance ❑ .. Work in Flood Zone ❑ .. Storm Drainage ❑ ...Deduct Water Meter Size ❑...Traffic Impact Analysis ❑...Hold Harmless — (SAO) ❑...Hold Harmless — (ROW) ❑ .. Grease Interceptor ❑ .. Channelization ❑ .. Trench Excavation ❑ .. Utility Undergrounding FINANCE INFORMATION Fire Line Size at Property Line ❑...Water ❑...Sewer Monthly Service Billing to: Number of Public Fire Hydrant(s) ❑ ...Sewage Treatment Name: Day Telephone: Mailing Address: City Water Meter Refund/Billing: Name: Day Telephone: Mailing Address: City State State Zip Zip Page 3 of 6 Unit Type: Qty Unit Type: Qty Unit Type: Qty Boiler /Compressor: Qty Fumace<100K BTU Air Handling Unit >10,000 CFM Fire Damper 0 -3 HP /100,000 BTU Furnace>100K BTU Evaporator Cooler Diffuser 3 -15 HP /500,000 BTU Floor Furnace Ventilation Fan Connected to Single Duct Thermostat 15 -30 HP /1,000,000 BTU Suspended/Wall/Floor Mounted Heater Ventilation System Wood/Gas Stove 30 -50 HP /1,750,000 BTU Appliance Vent Hood and Duct Water Heater 50+ HP /1,750,000 BTU Repair or Addition to Heat/Refrig/Cooling System Incinerator - Domestic Emergency Generator Air Handling Unit <10,000 CFM Incinerator — Comm/Ind Other Mechanical Equipment 1 MECHANICAL PERMIT INFORMATION - 206 -431 -3670 MECHANICAL CONTRACTOR INFORMATION Company Name: Mailing Address: Contact Person: Day Telephone: E -Mail Address: Fax Number: Expiration Date: Contractor Registration Number: Valuation of Project (contractor's bid price): $ Scope of Work (please provide detailed information): Use: Residential: New ....El Replacement ....El Commercial: New .... ❑ Replacement .... ❑ Fuel Tvoe: Electric ❑ Gas....❑ Other: Indicate type of mechanical work being installed and the quantity below: Q:UWlicuiore\Fonns- Applicniom On Line N3-2006 - Permit Appl cationdoc Review: 42006 bh k City State Zip Page 4 of 6 Fixture Type: Qty Fixture Type: ON Fixture Type: Qty Fixture Type: Qty Bathtub or combination bath/shower Drinking fountain or water cooler (per head) Wash fountain Gas piping outlets Bidet Food -waste grinder, commercial Receptor, indirect waste Clothes washer, domestic Floor drain Sinks Dental unit, cuspidor Shower, single head trap Urinals Dishwasher, domestic, with independent drain Lavatory Water Closet Building sewer or trailer park sewer Rain water system — per drain (inside building) Water heater and/or vent Industrial waste pretreatment interceptor, including its trap and vent, except for kitchen type grease interceptors Repair or alteration of water piping and/or water treating equipment Repair or alteration of drainage or vent piping Medical gas piping system serving one to five inlets/outlets for specific gas Additional medical gas inlets/outlets — six or more Q:UppliatiortFmme- Applica4wu On L neO-2006 - Permit Applicatiomdnc Revised: 42006 bb PLUMBING AND GAS PIPING PERMIT INFORMATION - 206 -431 -3670 PLUMBING AND GAS PIPING CONTRACTOR INFORMATION Company Name: Mailing Address: Indicate type of plumbing fixtures and/or gas piping outlets being installed and the quantity below: City State Zip Contact Person: I Day Telephone: E -Mail Address: Fax Number: Contractor Registration Number: Expiration Date: Valuation of Project (contractor's bid price): $ Scope of Work (please provide detailed information): Page 5 of 6 PERMIT APPLICATION NOTES — Applicable to all permits in this application Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. Building and Mechanical Permit The Building Official may grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). Plumbing Permit The Building Official may grant one extension of time for an additional period not exceeding 180 days. The extension shall be requested in writing and justifiable cause demonstrated. Section 103.4.3 Uniform Plumbing code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND 1 AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWN $ R THORIZ • ! GENT: Signature: ( 1� J / .�— F1C /.v/v v _ y Print Name: Ko V' " - � -- 1 - 6A41 Mailing Address: t' 2- 1°A iv ''a e< City Date Application Expires: Izlol� I Date Application Accepted: ad osl av Q:UppliationsWo s- Applications On Line N3-2006 - Permit Appliation.doc Revised: 42006 bh Date: v` Day Telephone: °- -72D ! oo J WA 18161 State Zip Staff Initials: Page 6 of 6 1 ACCOUNT ITEM LIST: Description Current Pmts City of Tukwila 6300 Southcenter BL, Suite 100 / Tukwila, WA 98188 / (206) 431 -3670 Parcel No.: 2623049106 Permit Number: D06 -207 Address* 1085 ANDOVER PK E TUKW Status: APPROVED Suite No: Applied Date: 06/05/2006 Applicant: INDUSTRIAL CASTER, CO Issue Date: Receipt No.: R06 -01206 Payment Amount: 315.88 Initials: BLH Payment Date: 08/07/2006 01:47 PM User ID: ADMIN Balance: 50.00 Payee: THE JULIE ANN CHAN FAMILY TRUST TRANSACTION LIST: Type Method Description Amount Payment Check 2331 315.88 BUILDING - NONRES STATE BUILDING SURCHARGE RECEIPT Account Code 000/322.100 311.38 000/386.904 4.50 Total: 315.88 -25O 08/07 9716 TOTAL 315 doc: Receipt Printed: 08-07 -2006 Parcel No.: Address: Suite No: Applicant: Receipt No.: Initials: User ID: Payee: ACCOUNT ITEM LIST: Description doc: Receipt Tukwila City of 6300 Southcenter BL, Suite 100 / Tukwila, WA 98188 / (206) 431 -3670 2623049106 1085 ANDOVER PK E TUKW INDUSTRIAL CASTER, CO R06 -00794 3EM 1165 CRAFT ARCHITECTS, PLLC TRANSACTION LIST: Type Method Payment Check PLAN CHECK - NONRES Description 2490 000/345.830 RECEIPT Account Code Permit Number: Status: Applied Date: Issue Date: Payment Amount: 202.40 Payment Date: 06/05/2006 02:50 PM Balance: $315.88 Amount 202.40 Current Pmts 202.40 Total: 202.40 D06 -207 PENDING 06/05/2006 6095 06/05 9716 TOTAL 202.40 Printed: 06-05 -2006 Prat: �/ /f ( r t_bri ea/ t tat( 4 4 Type of Inspection: /� 2 li 1l4c- ° Address: ✓7 /085 & i ((Wel Date Called: ecial Instructions: Date Wanted: ("2. — /3 -6 7 �am C p.m. Requester: Phone No: INSPECTION RECORD Retain a copy with permit CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 DOG -2D 7 06)43 - 6 p proved per applicable codes. D Corrections required prior to approval. COMMENTS: /2 rev / y 5-2 <0/4 6J /o t 37-i / $58.00 NSPECTI • ' FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to sechedule reinspection. Receipt No.: Date: . Project: I IQ cI'lus krA n l 0ev- Type of Inspection: / Susoe?rcae, p Ale A', Date Called: ' 111 � .` Address: 10 Anl pcN FQ Pt. E. Specia?Instructions: Date Wan z g —O CO Ca- I - p.m. Requester: Phone N.. 3 B 1 co G (G INSPEiION NO. INSPECTION RECORD Retain a copy with permit CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 Doi - zoo 06)431 -3 K 1 Approved per applicable codes. 0 Corrections required prior to approval. COMMENTS: 1 4tc ' /l 01 58.00 REINSPECTION FEE REQUI ICED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., S 'te 100. Call to sechedule reinspection. r: D W : z 8— d fir Receipt No.: (Date: Project: // n h e' //�� 11 4 i /Gl4, Type of In spe �yion: 9 a �/ i4 1/- Ad er i4Aa (Sate Called: c� Spe la Instructions: Date Wanted: a • Requester: Phone No: Approved per applicable codes. COMMENTS: INSPECTION RECORD Retain a copy with perm CITY OF TUKWILA BUILDING DIVISION 1" 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3 Inspector: 'Date: i ri $58.00 REINSPECTI6N FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to sechedule reinspection. 'Receipt No.: 'Date: IT NO. Corrections required prior to approval. Proj /11,4151/ 0,(4. Type of Inspection: 4 10 GT,.4,-,. Address: Date Called: Special nstructions: ,p /085 4i° !J Date Wanted: ��� -F ��m. Requester: Phone No: INSPECTION NO. INSPECTION RECORD Retain a copy with permit PER CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (0 )431 -36 COMMENTS: Approved per applicable codes. Corrections required prior to approval. r ate:8 / /1 ri $58.A0 FE t REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to sechedule reinspection. Receipt No.: 'Date: COMMENTS: Cit- -7 /'44 /2.-, o ) Sr / o -( 74, - )0,77+ -, .:/ ` is /4T /. D,._ ie 7 2i1/s -- "e A/ a / I/17 S Le SpC*t/C4 - el /C- TO SAJ-' i /e l e Gv'l /4" _ Lr"/ O 1 -rc.J /— s t eft /•, / 13 5 1- // Ctrri' p. m. Requester: ",, Phone No ao 6 s75 Project: n _L'VeflS�r,1 / lASa P/ Type of Inspection: P7109m /AV Address: /085 ON N o v e p rc Date Called: P Special Instructions: /, tse tT, / /I.�gt, a e c' /roc/ Date : Wante le /7 Ctrri' p. m. Requester: ",, Phone No ao 6 s75 /3 7 INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 Approved per applicable codes. nspe Receipt No.: INSPECTION RECORD Retain a copy with permit A' RE Q IR D G2 67 PE (206)431 -3 t �rf Corrections required prior to approval. Date: ) 7— C2 Y / � EE .00 REINSPECTION to inspection, fee must be id at 6300 Southcen ter Blvd. Suite 1 Call to sechedule reinspection. IDate: Project:..Zf/ovsrn IAA C 4tr- a- iNktea Type of Inspection: /Itr liN111.-- Address: /o f?S // PE: Suite #: Hood & Duct: Contact Person: Special Instructions: . , . _ .. % Phone No.: Needs Shift Inspection: Sprinklers: Fire Alarm: Hood & Duct: Monitor: Pre-Fire: Permits: Occupancy Type: 3 INSPECTION NUMBER CITY OF TUKWILA FIRE DEPARTMENT -VI per applicable codes. INSPECTION RECORD Retain a copy with permit Word /Inspection Record Form.Doc 1/13/06 T)o6 - 2n7 PERMIT NUMBERS 444 Andover Park East, Tukwila, Wa. 98188 206 - 575 -4407 H Corrections required piior to approval. COMMENTS: t PtI4L oiL Inspector: Q � 5 / Z T-� �J Date: 2 /12 /07 Hrs.: / $80.00 REINSPECTION FEE REQUIRED. You will receive an invoice from e City of Tukwila Finance Department. Call to schedule a reinspection., T.F.D. Form F.P. 113 COMMENTS: Type of Inspection: cc er L,,.,,n,_ 6) EZEm0VC PCA080t -Ts Pf2Dyn KY✓X /LICbNN e ft Don 2S / N WA fir h(*, Special Instructions: Permits: G..) move E x 7NGVISd'02. AT pcs K. e u,Z og5 2dcrri) SYIZINK. I--L OK . Project: CIA/0 vs rrt in L Cam sTr a 1 IAN -E -4 Type of Inspection: cc er L,,.,,n,_ Address: io0 5 Suite #: e3 PE" Contact Person: MARE 6 Ntt y Special Instructions: Permits: Phone No.: 706 67 - o4 Z3 Needs Shift Inspection: Sprinklers: Fire Alarm: Hood & Duct: Monitor: Pre -Fire: Permits: Occupancy Type: 2 r Park East, Tukwila, Wa. 98188 206- 575 -4407 n Approved per applicable codes. Inspector: INSPECTION NUMBER is z- Word /Inspection Record Form.Doc INSPECTION RECORD Retain a copy with permit CITY OF TUKWILA FIRE DEPARTMENT �o� -Zoe o6 -s- 173 PERMIT NUMBERS - Corrections required prior to approval. Date: 2 / / u7 Hrs.: / $80.00 REINSPECTION FEE REQUIRED. You will receive an invoice from e City of Tukwila Finance Department. Call to schedule a reinspection. 1/13/06 T.F.D. Form F.P. 113 Project: / / i �tnr /uS IGf f C.Gfsk2 /C�' ttJhee Type of Inspection: C j si / ar [e/ Coel< r Address: Suite #: IORC A Contact Person: Special Instructions: Phone No.: Needs Shift Inspection: 4/ Sprinklers: /7y/ Fire Alarm: Hood & Duct: Monitor: Pre -Fire: Permits: Occupancy Type: M INSPECTION NUMBER CITY OF TUKWILA FIRE DEPARTMENT 444 Andover Park East, Tukwila, Wa. 98188 206- 575 -4407 M Approved per applicable codes. INSPECTION RECORD Retain a copy with permit JDfl 12-2.07 PERMIT NUMBERS Corrections required prior to approval. COMMENTS: Ok' Et coo Pf So-‘ r Insp or: =� 70 Date: 9/j46 Hrs.:, 80.00 REINSPECTION FEE REQUIRED. You will receive an invoice from ity of Tukwila Finance Department. Call to schedule a reinspection. Word /Inspection Record Form.Doc 1/13/06 T.F.D. Form F.P. 113 `Project Info Project Address Andover Dark last - Industrial Cuter Datttee� Vt �� = y e ,�r kb k 0 . 6 - _ Area in ft (or If for perimeter) 1085 Andover Park Zest l� F F e'W�+'••'- -`^"°" f , AnooAVFll AUO 0 4 200 (/,)„ ' /� /I y� Office space Tukwila. WA. 98188 Applicant Name: Kathryn Taylor Applicant Address: 1932 /first Avenue Suite 408 Applicant Phone: t20s) 720 -7001 Project Description I New Building ❑ Addition 4 Alteration �PI dNkwiila Refer to WSEC Section 1513 for controls and commissi reuniNeDIVISION Compliance Option O Prescriptive Q Lighting Power Allowance 0 Systems Analysis (See Qualification Checklist (over). Indicate Prescriptive & LPA spaces clearly on plans.) Alteration Exceptions (check appropriate box - sec. 1132.3) ❑ No changes are being made to the lighting ❑ Less than 60% of the fixtures new, installed wattage not increased, & space use not changed. Location Description Allowed Watts per ft or per If Area in ft (or If for perimeter) Allowed Watts x tt (or x If) Covered Parking (standard paint) Office space 0.2 W /tt 296.0 296.0 Covered Parking (reflective paint) 0.3 W/ft !� ME M COPY Open Parking 0.2 W/ft n _ .. . . Outdoor Areas 296.0 0.2 W /ft Bldg. (by facade)' 0.25 W/fl Bldg. (by perim)' 7.5 Wilt Location (floor /room no.) Occupancy Description Allowed Watts per ft ** Area in 11 Allowed x Area Open Office 101 Office space 1. 00 296.0 296.0 " From Table 15-1 (over) - document all exceptions on form LTG -LPA Total Allowed Watts 296.0 Location (floor /room no.) Fixture Description Number of Fixtures Watts/ Fixture Watts Proposed Open Office 101 2x4 fluorescent fixture 3 96.0 288.0 Total Proposed Watts may not exceed Total Allowed Watts for Interior Total Proposed Watts 288.0 Location Fixture Description Number of Fixtures Watts/ Fixture Watts Proposed Total Proposed Watts may not exceed Total Allowed Watts for ExteriorriECENEOTotal Proposed Watts YARN K T IW/rl l Lighting Summary LTG -SUM Maximum Allowed Lighting Wattage (Interior) Proposed Lighting Wattage anterior) 2004 Washington State Nonresidential Energy Code Compliance Form Maximum Allowed Lighting Wattage (Exterior) Notes: 1. Use manufacturer's listed maximum input wattage. For hard -wired ballasts only, the default table in the NREC Technical Reference Manual may also be used 2. Include exit lights unless less than 5 watts per fixture. 3. List all fixtures. For exempt lighting, not exception and leave Watts/Fixture blank. 5 1. Choose either the facade area or the perimeter method, but not both) Total Allowed Watts Use mtgr listed maximum Input wattage. I-or fixtures with hard- , the default table in the NREC Technical Reference Manual may also be used. Proposed Lighting Wattage (Exterior) JUN 052006 Tito _2.-0* Use' LPA' (Mgt) Use' LPA`(W /sf) Painting, welding, carpentry, machine shops 2.3 Office buildings, office/administrative areas in facilities of other use types (including but not limited to schools hospitals, Institutions, museums, banks, churches) 1.0 Barber shops, beauty shops 2.0 Police and fire station? 1.0 Hotel banqueUconference/exhibition hall 2.0 Atria (atriums) 1.0 Laboratories 1.8 Assembly space?, auditoriums, gymnasia", heaters 1.0 Aircraft repair hangars 1.5 Group R -1 common areas 1.0 Cafeterias, fast food establishments' 1.5 Process plants 1.0 Factories, workshops, handlin{iareas 1.5 Restaurants/bars' 1.0 Gas stations, auto repair shop? 1.5 Locker and /or shower facilities 0.8 Institutions 1.5 Warehouses ", storage areas 0.5 Libraries' 1.5 Aircraft storage hangars 0.4 Nursing homes and hotel/motel guest rooms 1.5 Retail ° , retail banking 1.5 Wholesale stores (pallet rack shelving) 1.5 Parking garages (see exterior lighting) Section 1532 Mall concourses 1.4 Schools buildings (Group E occupancy only), school classrooms, day care centers 1.35 Plans Submitted for Common Areas Only' Laundries 1.2 Main floor building lobbies' (except mall concourses) 1.2 Medical Offices, Clinics" 1.2 Common areas, corridors, toilet facilities and washrooms, elevator lobbies 0.8 Prescriptive Spaces Occupancy: 0 Warehouses, storage areas or aircraft storage hangers 0 Other Qualification Checklist Lighting Check If all fixtures are ballasted and at least 95%* of fixtures are either: Note: If occupancy type is 'Other" and fixture Fixtures: answer is checked, the number of fixtures In (Section 1. Fluorescent fixtures which a) are non - lensed. b) have 1 or 2 two lamps c) have the space is not limited by Code. Clearly 1521) 5-60 watt T -1, T -2, T-4, T -5, T-6, T-8 lamps. d) have hard -wired electronic indicate these spaces on plans. If not dimming ballasts. Screw -in compact fluorescent fixtures do not qualify. qualified, do LPA Calculations. 2. Metal Halide with a) reflector b) ceramic MH lamps a 150w c) electronic ballasts ' - Exit and LED lights can be excluded from count if < 5 watts/fixture. 2004 Washington State Nonresidential Energy Code Compliance Fame TABLE 15 -1 Unit Lighting Power Allowance (LPA 2004 Washington State Nonresidential Energy Code Compliance Form Lighting Summary (back) LTG -SUM Footnotes for Table 15 -1 1) In cases in which a general use and a specific use are listed, the specific use shall apply. In cases in which a use is not mentioned specifically, the Unit Power Allowance shall be determined by the building official. This determination shall be based upon the most comparable use specified in the table. See Section 1512 for exempt areas. 2) The watts per square foot may be Increased, by two percent per foot of ceiling height above twenty feet, unless specifically directed otherwise by subsequent footnotes. 3) Watts per square foot of room may be increased by two percent per foot of ceiling height above twelve feet. 4) For all other spaces, such as seating and common areas, use the Unit Light Power Allowance for assembly. 5) Watts per square foot of room may be Increased by two percent per foot of ceiling height above nine feet. 6) See Section 1532 for exterior lighting. 7) For conference rooms and offices less than 150f9 with full height partitions, a Unit Lighting Power Allowance of 1.20 w/ft' maybe used. 8) For the fire engine room, the Unit Lighting Power Allowance is 1.0 watts per square foot. 9) For Indoor sport toumament courts with adjacent spectator seating, the Unit Lighting Power Allowance for the court area is 2.6 watts per square foot. 10) Display window illumination Installed within 2 feet of the window, provided that the display window is separated from the retail space by walls or at least three - quarter - height partitions (transparent or opaque). and lighting for free- standing display where the lighting moves with the display are exempt. An additional 1.5 w/fl of merchandise display luminaires are exempt provided that they comply with all three of the following: a) located on ceiling - mounted track or directly on or recessed into the ceiling itself (not on the wall). b) adjustable in both the horizontal and vertical axes (vertical axis only is acceptable for fluorescent and other fixtures with two points of track attachment). c) fitted with LED, tungsten halogen, fluorescent, or high intensity discharge lamps. This additional lighting power is allowed only if the lighting is actually installed. 11) Provided that a floor plan, Indicating rack location and height, is submitted, the square footage for a warehouse may be defined, for computing the interior Unit Lighting Power Allowance, as the floor area not covered by racks plus the vertical face area (access side only) of the racks. The height allowance defined In footnote 2 applies only to the floor area not covered by racks. 12) Medical and clinical offices Include those facilities which, although not providing ovemight patient care, do provide medical, dental, or psychological examination and treatment. These spaces Include, but are not limited to , laboratories and treatment centers. Revised May 2005 Space Heat Type 0 Electric resistance 0 All other (see over for definitions) Glazing Area Calculation Note: Below grade walls may be included in the Gross Exterior Wall Area if they are insulated to the level required for opaque walls. Total Glazing Area Electronic version: these values are automatically taken from ENV -UA -1. (rough opening) Gross Exterior (vertical & overhd) divided by Wall Area times 100 equals % Glazing T X 100 = Concrete /Masonry Option 0 yes Check here if using this option and if project meets all requirements for the Concrete/Masonry na Option. See Decision Flowchart (over) for qualifications. Enter requirements for each qualifying assembly below. Project Info Project Address Andover Park Zest - Industrial Caster 1085 Andover art r F nt �C NCE DEC MPLIA e• . 01)000vFO Alt 0 4 2006 I C U 98188 Applicant Name: Kathryn Taylor Applicant Address: 1931 Pint Avenue, Suite 408, Beattie, NA 98101 Applicant Phone: 206 - 720 -7001 Envelope Summary Climate Zone 1 ENV -SUM 2004 Washington State Nonresidential Energy Code Compliance Form Project Description Compliance Option ❑ New Building Envelope Requirements (enter values as applicable) Fully heated/cooled space Minimum Insulation R- values Roofs Over Attic All Other Roofs Opaque Walls' Below Grade Walls Floors Over Unconditioned Space Slabs-on-Grade Radiant Floors Opaque Doors Vertical Glazing Overhead Glazing Maximum U- factors Maximum SHGC (or SC) Vertical /Overhead Glazing Semi - heated apace 2 Minimum Insulation R- values Roofs Over Semi - Heated Spaces I N /A 1. Assemblies with metal framing must comply with overall U- factors 2. Refer to Section 1310 for qualifications and requirements Notes: 2004 Washington State Nonresidential Energy Code Compliance Form Addition Alteration ❑ Prescriptive El Component Performance (See Decision Flowchart (over) for qualifications) Revised May 2005 kwila MieDINUMLVISION Opaque Concrete /Masonry Wall Requirements Wall Maximum U- factor Is 0.15 (R5.7 continuous ins) CMU block walls with insulated cores comply If project qualifies for Concrete/Masonry Option, list walls with HC z 9.0 Btu)W °F below (other walls must meet Opaque Wall requirements). Use descriptions and values from Table 10-9 in the Code. Wall Description (including insulation R -value & position) rar r._. r!D, U- factor RACEIVED CCTV OF TUKWILA JUN 0 5 2006 ViRMIT CENTER ado -zrr+ Envelope Summary (back) Climate Zone 1 ENV -SUM 2004 Washington Stale Nonresidential Energy Code Compliance Forms Decision Flowchart for Prescriptive Option Use this flowchart to determine if project qualifies for the optional Prescriptive Option. If not, either the Component Performance or Systems Analysis Options must be used. 1302 Space Heat Type: For the purpose of detenal ng building envelope requirements, the following two categories comprise 11 space heating types: Other: All other space heating systems including go solid fuel, dl. and propane space heating systems and those systems li tad in the exception to electric resistance. (continued at ght) MI Insulation Installed? Below Grd Wall (ext) R -10 Below Grd Wall (oth) R -19 Roof Over Attic R -30 All Other Roof R -21 Raised Floor R -19 Slab -On -Grade R -10 Radiant Floor R -10 Opaque Door U -0.60 o L • Mass Wall Insulation Req. Mass Wall U0.15/R5.7ci CMU Block Ins. Cores Wood Frame R19 Metal Framed R19 Concrete/Masonry Option Assembly Description 2004 Washington State Nonresidential Energy Code Compliance Form Assy.Tag e ., Glazing Criteria Met? Glazing Area % 0-30% 30-45% >45% Vert OH UVaI UVel SHGC 0.55 0.70 0.45 0.45 0.60 0.40 Not Allowed Component Performance or Systems Analysis Required HC Totals Electric Resistance: Space heating systems which use Hectic resistance elements as the primary heating system Including baseboard. radiant, and forced air units where the total electric resistance heat capacity exceeds 1.0 We of the gross conditioned floor area. Exception: Heat pumps and terminal electric resistance heating in variable air volume distribution systems. Yes Glazing Criteria Met? Glazing Area % 0-30% >30 Vert OH UVal UVal SHGC 0.40 0.60 0.40 Not Allowed Prescriptive Y1 s Path Allowed Wall Heat Capacity (HC) Area (sf) Area weighted HC: divide total of (HC x area) by Total Area S i All Insulation Installed? Below Grd Wall (ext) Below Grd Wall (oth) Roof Over Attic All Other Roof Raised Floor Slab -On -Grade Radiant Floor Opaque Door Wood R -10 R -19 R -36 R -30 R -30 R -10 R -10 1.1-0.60 Metal R -10 U -0.062 U -0.031 U -0.034 U -0.029 R -10 R -10 U -0,60 Mass Wall Insulation Req. Mass Wall U0.15/R5.7ci CMU Block Ins. Cores Wood Frame R19 Metal Framed U0.062 HCxArea Revised May 2005 *If the area weighted heat capacity (HC) of the total above grade wall is a minimum of 9.0, the Concrete Masonry Option may be used. **For framed walls, assume HC =1.0 unless calculations are provided; for all other walls, use Section 1009. Project Address Andover Park Last - Industrial taster Date 6/5/2006 Space Heat Type Q Electric resistance 0 All other For Building Department Use Glazing Area as % gross exterior wall area Prop. 1 45. 0% Max.Target Concrete/Masonry Option 0 Yes 0 No Notes: If glazing area exceeds maximum allowed In Table, then calculate adjusted areas on back (over). Building Component List components by assembly ID & page # Proposed UA U- factor x Area (A) = UA (U x A) Target UA U- factor x Area (A) = UA (U x A) Owen Ieog U= Plan ID: U= Plan ID: U= Plan ID: U= Plan ID: U= Plan ID: U= Plan ID: U= Plan ID: 0.550 Glazing % Electric Resist. Other Heating 0-30% 0.40 0.55 >3045% see note above 0.45 I I Overhead Glazing I sow Imo U= Plan ID: U= Plan ID: U= Plan ID: U= Plan ID: 0.700 Glazing % Electric Resist. Other Heating 0-30% 0.6 0.7 >30 -45% see note above 0.6 1 sioowti o U= Plan ID: U= Plan ID: U= Plan ID: U= Plan ID: 0.700 Opaque Doors U= Plan ID: U= Plan ID: U= Plan ID: 0.600 Electric Resist. Other Heating 0.60 0.60 •114V 'GAO CIMV R =R - 30 Plan ID L - 11 exist + 1 R= Plan ID: R= Plan ID: 0.033 296.0 9.8 0.036 296.0 10.7 Electric Resist. Other Heating 0.031 0.036 s1OO21 Jagl) R= Plan ID: R= Plan ID: R= Plan ID: 0.046 Electric Resist. Other Heating 0.034 0.046 Opaque Walls' R= Plan ID: R= Plan ID: R= PIan ID: R= Plan ID: R= Plan ID: R= Plan ID: R= Plan ID: **Note: sum of Target Areas here should equal Target Opaque Wall Area (see back) `• •• Electric Resist. Other Heating Frame -Wd 0.062 0.062 Frame -M8 0.062 0.109 Mass Wall 0.15 0.15 ++ see mass wall Criteria anpm epe10 MMRO R= Plan ID: R= Plan ID: R= Plan ID: Note: If Insulated to levels required for opaque walls, list above with opaque walls Electric Resist. Other Heating Int Ins 0.062 0.062 Ext Ins 0.07 0.07 VuwW 1 JOAO NMIJ R= Plan ID: R= Plan ID: R= Plan ID: R= Plan ID: 0.056 Electric Resist. Other Heating 0.029 0.056 evvivvei °paid - IMI1p'o R= Plan ID: R= Plan ID: R= Plan ID: R= Plan ID: 0.540 Electric Resist. Other Heating F =0.54 F =0.54 (see Table 13 -1 for radiant floor values) , 'For CMU walls, indicate core insulation material. Totals! 296.0 9.8 Totals) 296.0 10.7 2004 Washington State Nonresidential Energy Code Compliance Form Envelope UA Calculations Climate Zonel ENV -UA 2004 Washington State Nonresidential Energy Code Compliance Form Revised May 2005 To comply: 1) Proposed Total UA shall not exceed Target Total UA 2) Proposed Total Area shall equal Target Total Area. Glazing List components by assembly ID & page # Proposed SHGC SHGC* x Area (A) = SHGC x A Target SHGC SHGC x Area (A) = SHGC x A Burzelo ID: ID: ID: ID: ID: ID: 0.450 Glazing % Electric Resist. Other Heating 0 -30% 0.4 0.45 >30-45% not allowed 0.4 •Note: Manufacturer's SC may be used in lieu of SHGC. Totals' Totals' Climate Zone 1 ENV -SHGC 2004 Washington State Nonresidential Energy Code Compliance Form For compliance: Proposed total SHGC x A shall not exceed Target total SHGC x A NOTE: Since 1997 SHGC compliance for vertical and overhead glazing Is allowed to be calculated together. Target Area Adjustment Calculations If the total amount of glazing area as a % of gross exterior wall area (calculated an ENV -SUMI) exceeds the malomum allowed in Table 13-7, then this calculation must be submitted Use the resulting areas In the Target UA and SHGC calculations above. Glazing Area Opaque Area Gross Exterior Wall Area IIC Roofs over Attics Other Roofs Walls) 2004 Washington State Nonresidential Energy Code Compliance Form Proposed Areas: Numbered values are used In calculations below. Roofs over Attics Other Roofs Wells 00= 296.0 00= VG= X Max Glazing Area (Table 13-1) 45.0% Target OG Area in Roofs over Attics �a lesser Proposed Opaque Area 296.0 t 100 Max 00 Remaining Proposed OG Area 1 Target OG Area In Other Roofs Maximum Target Glazing Area II less Target VG Area Target OG Area4' Target Opaque Area 1 296. Proposed Opaque Area Proposed VG Area Target VG Area I I + — I Note: If there is more than one type of wall, the Target VG Area may be distributed among them, and separate Target Opaque Areas found. H the Target Areas for Opaque Walls listed on the front must equal the total calculated here. Target Opaque Area Revised May 2005 Note: OG = overhead glazing VG = vertical glazing For Target OG's, the lesser values are used both here and below. I Target Areas OK Target values In shaded boxes are used in the applicable Target UA calculations on the front. Target VG Area and Total Target OG Area are also used In the applicable Target SHGC calculations above. March 7, 2007 Julie Chan 23215 — 66th Avenue S Kent, WA 98032 RE: Release of Bond Bond No. 104659313 Dear Ms. Chan: This letter authorizes release of the performance bond posted for the installation of the RPPA for domestic water, DDCVA for fire and irrigation water meter upgrade. This scope of work has installed and approved by the City inspector. If you should have any questions, please contact our office at (206)431 -3672. Sincerely, "aw,ui„ Oar Brenda Holt Permit Coordinator encl xc: Permit No. D06 -207 q:\docmnealslboad nleaseld05 -206 - ,lease letter.doc bh Steven M. Mullet, Mayor Department of Community Development Steve Lancaster, Director 6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone: 206- 431 -3670 • Fax: 206- 431 -3665 City of Tukwila 6300 Southcenter Blvd, Suite 100 Tukwila, WA 98188 206 -431 -3670 DEVELOPER'S PROJECT WARRANTY REQUEST FORM I Section 1- to be completed by Developer / Name of Development:M 4U s *fat castle/ Co Date: /3 / ( CC Address: /055 ,4-PE Release should be sent to: Name: ∎/ r /// G C a pl Address: 232 15 44 4 Ave. So City /State/Zip Kent WA I po 3 z D cn ion items t9 be completed (reference plans/doppu��ments where items a j� described): P' r items e k LIJ e/ !OC//4 To ,,L:•iw 104..4"/ iita osc M tor 60,.e_olc VVV Permit No.: DOC -.20? As the owner, or authorized agent of the owner, I hereby submit cash or cash equivalent in the amount of $ 63 2/0, 0 (150% of value to complete work above) and attach s yppoyt documentation for value of work. I will have this work carried out and call for a final inspection by this date: /r`! f0 or risk having the City use these funds to carry out the work with their own contractor or in -house manpower. If 1 fail to carry out the work, I hereby authorize the City to go onto the property and carry out completion of the above deficiencies. I further agree to complete all work listed above prior to requesting inspection and release ! f these funds. Signed: Title: Section 2- to be completed by City staff THIS FUND IS AUTHORIZED TO BE ACCEPTED Signed: J W Department Head: r y nPtars`. - Amount: $ b 6 , 210 ec Deposited this Date. ❑ Cash/Check ❑ Cash Assignment Q"Bond 1 0¢6 593 13 City Receipt No.: 7 - 3 / - oC- ?rDpe Mm•14 Received By: Section 3 -'to be completed by Developer All work identified in Section 1 of this form has now been completed and retumed to department which authorized warranty. I hereby request inspection and release of my cash /cash equivalent/bond. Developer's Representative: Date: To be completed by City staff I have reviewed the above work and found it acceptable and therefore authorize the release of the above h /cash equivalent/bond. Inspector. �� Date: - s/6/07 Section 4 - to be completed by City staff hetet Yams, 2003 1 Amount Released: $ 1051140 9 ❑ Check - Check No. ❑ Cash Equivalent — Letter attached crl Bond — Letter attached Date Released: Si • .D1 Released by:a July 31, 2006 City of Tukwila Attn: Joanna Spencer Department of PublicWorks 6300 Southcenter Boulevard, Suite 100 Tukwila, WA 98188 Re: Letter of Intent to Install RPPA Industrial Caster, Co. Tenant Improvement 1085 Andover Park East, Tukwila WA Permit No. D06 -207 Dear Ms. Spencer: In connection with the application for the above tenant improvement permit, ProLogis hereby posts a bond for $63,210 for the installation of an RPPA on the domestic water supply line pursuant your letter dated June 7, 2006 notifying us of the deficiencies on the domestic, fire prevention and landscape irrigation lines. Attached are 1) copies of the original design acid installation estimate, 2) a bond for $63,210 or 150% of the design and installation cost, and 3) this letter stating our intent to install the subject backflows. With the submittal of said bond, ProLogis herewith commits to installing a Reduced Pressure Principal Principle Assembly (RPPA) immediately downstream of the permanent water meter for the above premise location within 60 days of the issuance of the Industrial Caster, Co. Tenant Improvement permit. I appreciate your assistance in issuing the T.I. permit as expeditiously as possible. If you have questions please contact me or Kathy Craft at Craft Architects, (206) 720 -7001. Sincerely, ProLogis ulie Chan Property Manager cc: Kathy Craft ratina a, MINA r usuyiae The Global Distribution Solution ProLogis • 23215 66th Avenue South • Kent Washington 98032 • Telephone 253 520 -0244 • Facsimile 253 859 -1809 PERMIT BOND Travelers Casualty and ourety Company of America One Tower Square 3PB, Hartford, CT 06183 (License or Permit - Continuous) Bond No. 104659313 KNOW ALL MEN BY THESE PRESENTS: THAT WE, ProLogis as Principal, and Travelers Casualty and Surety Company of America, a corporation duly incorporated under the laws of the State of Connecticut and authorized to do business in the State of Washington, as Surety, are held and firmly bound unto City of Tukwila, Dept. of Community Development as Obligee, in the penal sum of Sixty Three Thousand Two Hundred Ten and No /100 ($63,210.00) Dollars, for the payment of which we hereby bind ourselves, our heirs, executors and administrators, jointly and severally, firmly by these presents. WHEREAS, the Principal has obtained or is about to obtain a license or permit for Industrial Caster,. Co - Andover East Business Park. Permit App. No. D06 -207.. NOW, THEREFORE, THE CONDITIONS OF THIS OBLIGATION ARE SUCH, that if the Principal shall faithfully perform all duties and protect said Obligee from any damage caused by the Principal's non - compliance with or breach of any laws, statutes, ordinances, rules or regulations, pertaining to the license or permit issued, then this obligation shall be null and void; otherwise to remain in full force and effect. This bond shall become effective on the 26th day of July, 2006. PROVIDED, that regardless of the number of years this bond is in force, the Surety shall not be liable hereunder for a larger amount, in the aggregate, than the penal sum listed above. PROVIDED FURTHER, that the Surety may terminate its liability hereunder as to future acts of the Principal at any time by giving Thirty (30) days written notice of such termination to the Obligee. SIGNED, SEALED AND DATED this 26th day of July, 2006. S -2151A (02 -00) ProLogis By: ze- Edward S. Nekritz, Managing Director , Principal By: Travelers Casualty and Surety Company of America ic Mark 'Ro po, A rney -in -Fact CALIFORNIA ALL - PURPOSE ACKNOWLEDGMENT State of California County of SAN FRANCISCO KATHERINE G. ZEROUNIAN Commission # 1588102 Notary Public • California San Francisco County f My Comm. Expire Jun 29.2 Place Notary Seal Above Document Date: Tss On July 26, 2006 before me, KATHERINE G. ZEROUNIAN. NOTARY PUBLIC Date Name and Title of Officer (e.g., 'Jane Doe, Notary Public') personally appeared MARK ROPPO Name(s) of Signer(s) ® personally known to me evidence to be the persons)- whose name(s) is/are subscribed to the within instrument and acknowledged to me that he/sheithey executed the same in his/her/theiw authorized capacity(ies), and that by hisTherr/their signature($ on the instrument the person(e), or the entity upon behalf of which the person($ acted, executed the instrument. WITNESS my hand and official seal. h S', at re of Notary Public OPTIONAL Though the information below is not required by law, it may prove valuable to persons relying on the document and could prevent fraudulent removal and reattachment of this form to another document. Description of Attached Document Title or Type of Document: Number of Pages: Signer(s) Other Than Name Above: Capacity(les) Claimed by Signer Signer's Name: ❑ Individual ❑ Corporation Officer — Title(s): ❑ Partner — ❑ Limited ❑ General ❑ Attorney in Fact ❑ Trustee ❑ Guardian or Conservator ❑ Other: Signer Is Representing: RIGHT THUMBPRINT OF SIGNER Top of thumb here 43 1999Nalional Notary Association• 9350 De Solo Ave., P.O. Box 2402• Chatsworth, CA 91313-2402' ema.nationanobyarg Prod. No. 0E07 Reorder Cal TeLLFree 1100878-8827 VOTED: That the signature of each of the following officers: President, any Executive Vice President, any Senior Vice President, any Vice President, any Assistant Vice President, any Secretary, any Assistant Secretary, and the seal of the Company may be affixed by facsimile to any power of attorney or to any certificate relating thereto appointing Resident Vice Presidents, Resident Assistant Secretaries or Auonu. s -in -Fact for purposes only of executing and atteitirtg bonds and undertakings and other writings obligatory in the nature thereof, and any such power of attorney or certificate bearing such facsimile signature or facsimile seal shall be valid and binding upon the Company and any such power so executed and certified by such facsimile signature and facsimile seal shall be valid and binding upon the Company in the future with respect to any bond or undertaking to which it is attached. TRAVEL_ _ S CASUALTY AND SURETY COMPANY OF £ERICA TRAVELERS CASUALTY AND SURETY COMPANY FARMINGTON CASUALTY COMPANY Hartford. Connecticut 06183.9062 POWER OF ATTORNEY AND CERTIFICATE OF AUTHORITY OF ATTORNEY(S) -fN -FACT KNOW ALL PERSONS BY THESE PRESENTS, THAT TRAVELERS CASUALTY AND SURETY COMPANY OF AMERICA, TRAVELERS CASUALTY AND SURETY COMPANY and FARMINGTON CASUALTY COMPANY, corporations duly organized under the laws of the State of Connecticut, and having their principal offices in thc City of Hartford, County of Hartford, State of Connecticut, (hereinafter the `Companies ") Rath made, constituted and appointed, and do by these presents make, constitute and appoint: John T. Lettieri, Mark Roppo, Paul Rodriguez, Katherine G. Zerouoiao, Tom Branigan, of San Francisco, California, their true and lawful Attorncy(s) -in -Fact, with full power and authority hereby conferred to sign, execute and acknowledge, at any place within the United States, the following instrument(s): by his/her sole signature and act, any and all bonds, rccognizances, contracts of indemnity, and other writings obligatory in the nature of a bond, recognizance, or conditional undertaking and any and all consents incident thereto and to bind the Companies, thereby as fully and to the same extent as if the same were signed by the duly authorized officers of the Companies, and all thc acts of said Attorneys) -in -Face pursuant to the authority herein given are hereby ratified and confirmed. This appointment is made under and by authority of thc following Standing Resolutions of said Companies, which Resolutions are now in full force and effect: VOTED: That the Chairman, the President, any Vice Chairman, any Executive Vice President, any Senior Vice President, any Vioe President, any Second Vice President, the Treasurer, any Assistant Treasurer, the Corporate Secretary or any Assistant Secretary may appoint Attomeys-in -Fact and Agents to act for and on behalf of the company and may give such appointee such authority as his or her certificate of authority may prescribe to sign with the Company's name and seal with the Company's seal bonds, recognizance-5, contracts of indemnity, and other writings obligatory in the nature of a bond, recognizance, or conditional undertaking, and any of said officers or the Board of Directors at any time may remove any such appointee and revoke the power given him or h•a. VOTED: That the Chairman, the President, any Vice Chairman, any Executive Vice President, any Senior Vice President or any Vice President may delegate all or any part of the foregoing authority to ono or more officers or employees of this Company, provided that each such delegation is in writing and a copy thereof is filed in the office of the Secretary. VOTED: That any bond, recognizance, coetract of indemnity, or writing obligatory in the nature of a bond, recognizance, or conditional undertaking shall be valid and binding upon the Company when (a) signed by the President, any Vice Chairman, any Executive Vice President, any Senior Vice President or any Vice President, any Second Vice President, the Treasurer, any Assistant Treasurer, the Corporate Secretary or any Assistant Secretary and duly attested and sealed with the Company's seal by a Secretary or Assistant Secretary, or (b) duly executed (under seal, if required) by one or more Attorneys -in -Fact and Agents pursuant to the power prescribed in his or her certificate or their certificates of authority or by one or tmorc Company officers pursuant to a written delegation of authority. This Power of Attorney and Certificate of Authority is signed and sealed by facsimile (mechanical or printed) under and by authority of the following Standing Resolution voted by the Boards of Directors of TRAVELERS CASUALTY AND SURETY COMPANY OF AMERICA, TRAVELERS CASUALTY AND SURETY COMPANY and FARMINGTON CASUALTY COMPANY, which Resolution is now in full force and effect: (II-00 Standard) COLORADO ALL - PURPOSE ACKNOWLEDGEMENT State of Colorado ) ) ss. • County of Ire-1r ) On MA Arc28, eS X�(p , before me, Lc5h n A , a Notary Public, in and for said state, personally appeared €1 WO Arai S WPkn t7 , personally known to me (or proved to me on the basis of satisfactory evidence) to be the person whose name is subscribed to the within instrument and acknowledged to me that they executed the same in their authorized capacity, and that by their signature on the instrument, the person, or the entity upon behalf of which the person acted, executed the instrument. WITNESS my hand and official seal. (SEAL) Uy fls1aiEOss0ti07t200a Signature of Notary Public S SMITH FIRE SYSTEMS, INC. South Puget Sound 1106 54"Avenue East Tacoma WA 98424 Email: www.smfthfire.corq (253) 9261880 Phone (253) 926 2350 Fax North Puget Sound 3813168 Street NE Ste. 1 Arlington WA 98223 FIRE SPRINKLER BID PROPOSAL PROJECT NAME: ANDOVER PARK EAST -BFP UPGRADE DATE: 6/30/06 ADDRESS: 1085 ANDOVER PARK EAST PAGE: 1 OF 1 CITY i COUNTY TUKWILA SPEC SECTION: FIRE SPRINKLER - BACKFLOW BIDDING TO: PROLOG'S, INC. FAX NO.: 253-859 -1809 ATTENTION: JULIE CHAN ESTIMATE NO.: 1106-0612 Email: www.smfhfire.com (360) 651 -7701 Phone (360) 651 -2419 Fax BASE PRICE: 533,880.00 SALES TAX INCLUDED: ❑ YES © NO APPROVALS CITY TUKWILA COUNTY INSURANCE OTHER This proposal is based upon the following: SMITH FIRE SYSTEMS WILL PROVIDE THE DESIGN, MATERIALS, EQUIPMENT AND INSTALLATION LABOR TO INSTALL A NEW DOUBLE DETECTOR CHECK VALVE ( DDCVA) TO THE EXISTING FIRE LINE ONLY. ALL WORK WILL BE INSTALLED PER THE CITY OF TUKWILA DEPARTMENT OF PUBLIC WORKS REFERENCE DETAIL WS-15 (20F2). SFS WILL REMOVE THE EXISTING CONTROL VALVES, SINGLE CHECK AND PIPING IN THE EXISTING VAULT THEN WE WILL INSTALL. A NEW VAULT NEXT TO THE EXISTING VAULT. THIS QUOTE INCLUDES THE FOLLOWING ITEMS, 8' DDCVA, ALL TAMPER SWITCHES, 8' NRS VALVE FOR PIN, MODEL 4484 CONCRETE UTILTY VAULT AND ALL PIPING AND FITTINGS FOR A PROPER INSTALLATION. CLARIFICATIONS: 1) PERMIT FEES ARE IN INCLUDED BASED ON CURRENTLY PUBLISHED SCHEDULES. 2) SFS WILL PROVIDE A BACKHOE AND OPERATOR FOR VAULT INSTALLATION. 3) SOME LANDSCAPING WILL NEED TO BE REMOVED DURING THE CONSTRUCTION PHASE, ANY REPAIR OR REPLACEMENT IS TO BE BY OTHERS. 4) SFS WILL USE THE SERVICES OF A UTILITY LOCATOR TO LOCATE ANY EXISTING UNDERGROUND PIPING, ANY REMOVAL OR RELOCATION OF BURIED OR HIDDEN ITEMS WILL BE AT AN ADDITIONAL COST. 5) ALARM WORK OR ELECTRICAL WIRING IS NOT INCLUDED. PLEASE CALL ME IF YOU HAVE ANY QUESTIONS. SFS ESTIMATOR: WALLY REEVES E -MAIL wreeves©smithfire.com ACCEPTED BY: DATE' NAME TITLE S poke- tv Mike. Cu sI Ck JULIE CHAN JULIE CHAN PROLCGIS 23215 66TH AVE SOUTH KENT, WA 98032 ' twos (253)520 -0244 Ira (253)859 -1809 PROPOSAL. 17473 Page 1 Merit Mel, Inc. PO Box 2109 Redmond. WA 98073 -2109 Phone: (4 8830224 Pew (425) 867-0962 oat. 07/26/2006 I Poo gams/ JULIE CLAN LOOStiet PROLOGIS ANDOVER PARE EAST BUILDING 1071 -1097 ANDOVER PARK EAST SEATTLE, WA 98188 woos (253)520 -0244 I na (253)859 -1809 PROJECT DESCRIPTION: PART 1: Domestic Water Supply Install a new 2" Reduced Pressure Aseembly on the water service just after the city water meter. See cut sheet Due to apace constraint, the device will be installed to the south where there is ample space. Excavate for supply to and from RPPA, connections to main water supply, Depth of trench will be 18" to 24" depending on depth of existing water supply to fire prevention system. Pour a new concrete pad for the device and hot box. Provide and install a new "Rot Box" to insulate the new device and piping, Prior to installation and or excavation, a plan review by the City of Tukwila is required. Provide permit and backflow certification. PART 2: Deduct Meter Provide and install a new Sensus ECR •WP deduct meter which will replace the existing meter located on the irrigation supply. THIS PROPOSAL INCLUDES: Labor and materials, Plan review and permit, Certification of RPPA, Excavating and Backillling, Follow Specifications and requirements provided by Julie Chan as well as City of Tukwila, Set removed sod in place, Any remaining product to be hauled off.,site. Work to be complete during normal business hours, 8:00 AM to 4:00 PM. THIS PROPOSAL EXCLUDES: Sales Tax, Electrical supply to Hot Box, Unforeseen obstacles (irrigation, electrical), Guarantee on connections to existing piping, Relocating water supply to fire system, Repairs to any water cooled units or water supplied fixtures on or within building or buildings. (Continued) PROPOSALN°• 17473 Page 2 Melt Mechantcat, Inc. PO Box 2409 Redmond, WA 08073-2109 P Phone: #4 - 2 2 T°t JULIE CHAti JULIE CBAN I 23215 6 6 23215 6TH AVE SOUTH KENT, WA 98032 2 13140 07/26/2006 II° Ions/ JULIE CHAN FOR PROWGIS ANDOVER PARK EAST BUILDING 1071 -1097 ANDOVER PARK EAST SEATTLE, NA 98188 Mx* (253)520 - 0244 I ss (253)859 - 1809 3booa (253)520 - 0244 I ram (253)859 - 1809 Eight Thousand Two Hundred. Sixty Dollars and 00 cants $0,260.00 Passant to ba aada as follows: WM= n03EE33 EII.L23ZG3 3017 30 LAIL, rat 32 NET 30 Dana DOA UYOICZ) 1 3/41 •: a a MR= ):OmT37d 00 atdi 113 57 Wit *I T$. 1 an ma amass a ALL eananinCA am MMZRTats. awmctmss cam at III zonamr, tees, iazcs, Mb COBTaW S. s0 MOM= a am Int2arni as ZOOM= taaVIOID sT OT no. t0 wTaaiVt A an mono nor, nmeTaa, ram ono. twaa. as [amnia. Authorised " 1 signature a1+� !Submitted By: Jia Perkins mete: mess .. bo withdrawn by as i 30 doss Aocoptan°e of Proposal Date of Acceptance: ��--- 2 . .�6 .2iSn / dignataro k Print frame f Y / 02-02 -2007 JULIE CHAN 23215 66 AV S KENT WA 98032 RE: Permit No. D06 -207 1085 ANDOVER PK E TUKW Dear Permit Holder: City of Tukwila Steven M. Mullet, Mayor Department of Community Development Steve Lancaster, Director In reviewing our current records the above noted permit has not received a final inspection by the City of Tukwila Building Division. Per the International Building Code and/or the International Mechanical Code, every permit issued by the Building Division under the provisions of this code shall expire by limitation and become null and void if the building or work authorized by such permit is not commenced within 180 days from the date of such permit, or if the building or work authorized by such permit is suspended or abandoned at any time after the work is commenced for a period of 180 days. Based on the above, you are hereby advised to: Call the City of Tukwila Inspection Request Line at 206-431 -2451 to schedule for the next or final inspection. This inspection is intended to determine if substantial work has been accomplished since issuance of the permit or last inspection; or if the project should be considered abandoned. If such determination is made, the Building Code does allow the Building Official to approve one or more extensions of time for additional periods not exceeding 90 days each. Extension requests must be In writtnR and provide satisfactory reasons why circumstances beyond the applicants control have prevented action from being taken. In the event you do not call for the above inspection and receive an extension prior to 03/27/2007 , your permit will become null and void and any further work on the project will require a new permit and associated fees. Thank you for your cooperation in this matter. Sincerely, cot Ak44 Permit Technician xe: Permit File No. D06-207 6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone: 206.431 -3670 • Fax: 206-431-3665 July 31, 2006 City of Tukwila Attn: Joanna Spencer Department of PublicWorks 6300 Southcenter Boulevard, Suite 100 Tukwila, WA 98188 Re: Letter of Intent to Install RPPA Industrial Caster, Co. Tenant Improvement 1085 Andover Park East, Tukwila WA Permit No. D06 -207 Dear Ms. Spencer: In connection with the application for the above tenant improvement permit, ProLogis hereby posts a bond for $63,210 for the installation of an RPPA on the domestic water supply line pursuant your letter dated June 7, 2006 notifying us of the deficiencies on the domestic, fire prevention and landscape irrigation lines. Attached are 1) copies of the original design and installation estimate, 2) a bond for $63,210 or 150% of the design and installation cost, and 3) this letter stating our intent to install the subject backflows. With the submittal of said bond, ProLogis herewith commits to installing a Reduced Pressure Principal Principle Assembly (RPPA) immediately downstream of the permanent water meter for the above premise location within 60 days of the issuance of the Industrial Caster, Co. Tenant Improvement permit. I appreciate your assistance in issuing the T.I. permit as expeditiously as possible. If you have questions please contact me or Kathy Craft at Craft Architects, (206) 720 - 7001. Sincerely, ProLogis Julie Chan Property Manager cc: Kathy Craft Sa a pi AN.n ' : rr/ uLuy/a® The Global Distribution Solution CORRECTION LTR# 1 D&oW1 Prologis • 23215 66th Avenue South • Kent Washington 98032 • Telephone 253 520-0244 • Facsimile 253 859 -1809 MEND CITY Of TUKWII.A 41.16 0 2 2006 PERMIT CENTER % City of Tukwila 6300 Southcenter Blvd, Suite 100 Tukwila, WA 98188 206 -431 -3670 DEVELOPER'S PROJECT WARRANTY REQUEST FORM I Section 1 - to be completed by Developer Name of Development:Tf d •• l •,Si iQJ C ' 2 k e , Date: 7f 3I I c Address' /0 85 A PermitNo.: .006 _ .207 Release should be sent to: Name: 37/1/ G Cha �� tt � Address: Z321S 64 �' /t4i:. So City /state /Zip K v1-A '1 go 3 2- Descri o lin is tqq e completereference pla items aft ded): ��� p/ tem szt o b e co pe d ( /.Jg p l bt eu4 / „4•i! escrib ed): inliOAQ.Abit tyrat. As the owner, or authorized agent of the owner, 1 hereby submit cash or cash equivalent in the amount of $ 65 210. 0 (150% of value to complete work above) and attach slippopt documentation for value of work. I will have this work carried out and call for a final inspection by this date: /0 d/ OR or risk having the City use these funds to carry out the work with their own contractor or in -house manpower. If I fail to carry out the work, 1 hereby authorize the City to go onto the property and carry out completion of the above deficiencies. I further agree to complete all work listed above prior to requesting inspection and release 11f these funds. Signed: _ Title: U 7 -3 /-e, (-, P/Di es ' / Manor o U I, Section 2 — tobe completed by City staff THIS FUND IS AUTHORIZED TO BE ACCEPTED Signed: jr partment Head: _ c�/LSe-ryt. -. Amount: $ fo3� 2/0 Deposited this Date ❑ Cash /Check ❑ Cash Assignment Cnond 1 04 6 593 /3 City Receipt No.: Received By: Section 3 - to be completed by Developer All work identified in Section 1 of this form has now been completed and retumed to department which authorized warranty. I hereby request inspection and release of my cash /cash equivalent/bond. Developer's Representative: Date: Inspector. To be completed by City staff I have reviewed the above work and found it acceptable and therefore authorize the release of the above cash /cash equivalent/bond. I Section 4 - to be completed by City staff v W O - .emY& W I .w.Mad W.. .;• ..r-y *WM Ueel Felinity 2443 Date: Authorized By: Amount Released: $ ❑ Check - Check No. ❑ Cash Equivalent - Letter attached ❑ Bond - Letter attached Date Released: Released by: PERMIT BOND (License or Permit - Continuous) Bond No. 104659313 KNOW ALL MEN BY THESE PRESENTS: THAT WE, ProLogis as Principal, and Travelers Casualty and Surety Company of America, a corporation duly incorporated under the Taws of the State of Connecticut and authorized to do business in the State of Washington, as Surety, are held and firmly bound unto City of Tukwila, Dept. of Community Development, as Obligee, in the penal sum of Sixty Three Thousand Two Hundred Ten and No /100 ($63,210.00) Dollars, for the payment of which we hereby bind ourselves, our heirs, executors and administrators, jointly and severally, firmly by these presents. WHEREAS, the Principal has obtained or is about to obtain a license or permit for Industrial Caster, Co - Andover East Business Park. Permit App. No. D06 -207.. NOW, THEREFORE, THE CONDITIONS OF THIS OBLIGATION ARE SUCH, that if the Principal shall faithfully perform all duties and protect said Obligee from any damage caused by the Principal's non - compliance with or breach of any laws, statutes, ordinances, rules or regulations, pertaining to the license or permit issued, then this obligation shall be null and void; otherwise to remain in full force and effect. This bond shall become effective on the 26th day of July 2006. PROVIDED, that regardless of the number of years this bond is in force, the Surety shall not be liable hereunder for a larger amount, in the aggregate, than the penal sum listed above. PROVIDED FURTHER, that the Surety may terminate its liability hereunder as to future acts of the Principal at any time by giving Thirty (30) days written notice of such termination to the Obligee. SIGNED, SEALED AND DATED this 26th day of July 2006. S -2151A (02 -00) Travelers Casualty anurety Company of America One Tower Square 3PB, Hartford, CT 06183 ProLogis By: Sid J- Edward S. Nekritz, Managing Director , Principal Travelers Casualty and Surety Company of America I 1i Mark Roppo, A •rney -in -Fact CALIFORNIA ALL - PURPOSE ACKNOWLEDGMENT ,aao-aaaaaaaaw -ati-N ..w":.xu.< -Fefie as aro-btieee;wXr rr,<, sr,',:.cr+,u ma÷ State of California ss County of SAN FRANCISCO On July 26, 2006 before me KATHERINE G. ZEROUNIAN, NOTARY PUBLIC Date Name and Title of Officer (e.g., "Jane Doe, Notary Public') personally appeared MARK ROPPO $ .�� Commission # 1588102 !.� KATHERINE G. ZEROUMAN Y y s Notary Public - California ,. � San Francisco County " "•:" My Comm. Expires Jun 29, 2009 Place Notary Seal Above Name(s) of Signer(s) ® personally known to me ❑ proved to mo on the basis of satisfactory evidence OPTIONAL to be the personfs} whose names) is/are subscribed to the within instrument and acknowledged to me that he/she/they executed the same in hislhor /their authorized capacity(ies), and that by his/her/thei; signature($ on the instrument the persons or the entity upon behalf of which the person($ acted, executed the instrument. WITNESS my hand and official seal. Si. at re of Notary Public Though the information below is not required by law, ft may prove valuable to persons relying on the document and could prevent fraudulent removal and reattachment of this form to another document. Description of Attached Document Title or Type of Document: Document Date: Signer(s) Other Than Name Above: Capacity(ies) Claimed by Signer Signer's Name: ❑ Individual ❑ Corporation Officer -- Title(s): ❑ Partner — ❑ ; Limited ❑ General ❑ Attorney in Fact ❑ Trustee ❑ Guardian or Conservator ❑ Other: Signer Is Representing: aaacaaao-aa •0. „-, Number of Pages: .: RIGHTTHUMBPRINT Top of thumb here va��o.pao-�vv o-aooaaMav+ ® 1999 National Notary Association ' 9350 De Soto Ave., P.O. Box 2402 CtiatswOM, CA 9131 12402' we.nawnasnobyay Rod No GEO7 Reaper CylToLLRee 14008724822 (11-00 Standard) TRAVES CASUALTY AND SURETY COMPANY O1iarrtfERICA TRAVELERS CASUALTY AND SURETY COMPANY FARMINGTON CASUALTY COMPANY Hartford, Connecticut 06183 -9062 POWER OF ATTORNEY AND CERTIFICATE OF AUTHORITY OF ATTORNEY(S) -IN -FACT KNOW ALL PERSONS BY THESE PRESENTS, THAT TRAVELERS CASUALTY AND SURETY COMPANY OF AMERICA, TRAVELERS CASUALTY AND SURETY COMPANY and FARMINGTON CASUALTY COMPANY, corporations duly organized under the laws of the State of Connecticut, and having their principal offices In the City of Hartford, County of Hartford, State of Connecticut, (hereinafter the "Companies ") hath made, constituted and appointed, and do by these presents make, constitute and appoint: John T. Lettieri, Mark Roppo, Paul Rodriguez, Katherine G. Zerouaiao, Torn 13 ranigan, of San Francisco, California, their true and !awful Attorney(s) - in - Fact, with full power and authority hereby conferred to sign, execute and acknowledge, at any place within the United States, the following instrument(s): by his/her sole signature and act, any and all bonds, recognizances, contracts of indemnity, and other writings obligatory in the nature of a bond, recognizance, or conditional undertaking and any and all consents incident thereto and to bind the Companies, thereby as fully and to the same extent as if the same were signed by the duly authorized officers of the Companies, and all the acts of said Attorney(s) -in -Fact, pursuant to the authority herein given, are hereby ratified and confirmed This appointment is made under and by authority of thc following Standing Resolutions of said Companies, which Resolutions are now in full force and effect: VOTED: That the Chairman, the President, any Vice Chairman, any Executive Vice President, any Senior Vicc President, any Vice President, any Second Vice President, the Treasurer, any Assistant Treasurer, the Corporate Secretary or any Assistant Secretary may appoint Attomeys - in - Fact and Agents to act for and on behalf of the company and may give such appointee such authority as his or her certificate of authority may prescribe to sign with the Company's name and seal with the Company's seat bonds, recognizances, contracts of indemnity, and other writings obligatory in the nature of a bond, recognizance, or conditional undertaking, and any of said officers or the Board of Directors at any time may remove any such appointee and revoke the power given him or ha. VOTED: That the Chairman, the President, any Vice Chairman, any Executive Vice President, any Senior Vice Prcaident or any Vice President may delegate all or any part of the foregoing authority to one or more oniceas or cthployees of this Company, provided that each such delegation is in writing and a copy thereof is filed in the office of the Secretary. VOTED: That any bond, recognizance, coctract of indemnity, or writing obligatory in the nature of a bond, recognizance, or conditional undertaking shall be valid and binding upon the. Company when (a) signed by the President, any Vicc Chairman, any Executive Vice President, any Senior Vice President or any Vice President, any Second Vice President, the Treasurer, any Assistant Treasurer, the Corporate Secretary or any Assistant Secretary and duly attested and sealed with the Company's seal by a Secretary or Assistant Secretary, or (b) duly executed (under seal, if required) by one or more Attorneys -tit -Pact and Agents pursuant to the power prescribed in his or her certificate or their certificates of authority or by one or more Company officers pursuant to a written delegation of authority, This Power of Attorney and Certificate of Authority is signed and sealed by facsimile (mechanical or printed) under and by authority of the following Standing Resolution voted by the Boards of Directors of TRAVELERS CASUALTY AND SURETY COMPANY OF AMERICA, TRAVELERS CASUALTY AND SURETY COMPANY and FARMINGTON CASUALTY COMPANY, which Resolution is now in full force and effect: VOTED: That the signature of each of the following officers: President, any Executive Vice President, any Senior Vice President, any Vice President, any Assistant Vice President, any Secretary, any Assistant Secretary, and the seal of the Company may be affixed by facsimile to any power of attorney or to any certificate relating thereto appointing Resident Vice Presidents, Resident Assistant Secretaries or Attorneys-in-Fact for purposes only of executing and attesting bonds and undertakings and other writings obligatory in the nature thereof, and any such power of attorney or certificate bearing such facsimile signature or facsimile seal shall be valid and binding upon the Company and any such power so executed and certified by such facsimile signature and facsimile seal shall be valid and binding upon the Company in the future with respect to any bond or undertaking to which it is attached IN WITNESS WHEREOF, TRAVELERS CASUALTY AND SURETY COMPANY OF AMERICA, TRAVELERS CASUALTY AND SURETY COMPANY and FARMINGTON CASUALTY COMPANY have caused this instrument to be signed by their Senior Vice President and their corporate seals to be hereto affixed this 22nd day of November, 2003. STATE OF CONNECTICUT JSS. Hartford COUNTY OF HARTFORD #4 ) TRAVELERS CASUALTY AND SURETY COMPANY OF AMERICA TRAVELERS CASUALTY AND SURETY COMPANY FARMINGTON CASUALTY COMPANY George W. Thompson Senior Vice President On this 22nd day of November, 2003 before me personalty came GEORGE W. THOMPSON to me known, who, being by me duly sworn, did depose and say. that he/she is Senior Vice President of TRAVELERS CASUALTY AND SURETY COMPANY OF AMERICA, TRAVELERS CASUALTY AND SURETY COMPANY and FARMINGTON CASUALTY COMPANY, the oorporations described in and which executed the above instrument; that he /she knows the seals of said corporations; that the seals affixed to the said instrument are such corporate seals; and that he/she executed the said instrument on. behalf of the corporations by authority of his/her office under the Standing Resolutions thereof. R My commission expires June 30, 2006 Notary Public Marie C. Tetreault CERTIFICATE I, the undersigned, Assistant Secretary of TRAVELERS CASUALTY AND SURETY COMPANY OR AMERICA, TRAVELERS CASUALTY AND SURETY COMPANY and FARMINGTON CASUALTY COMPANY, stock corporations of the State of Connecticut, DO HEREBY CERTIFY that the foregoing and aaached Power of Attorney and Certificate of Authority remains in Cult force and has not been revoked; and furthermore, that thc Standing Resolutions of' the Boards of Directors, as set forth in the Certificate of Authority, are now in force. Signed and Sealed at the Home Office of the Company, in thc City of Hartford, State of Connecticut. Dated this 26Th day of JULY ,20 06 By '""' i2C`r------, Kori M. Johanson Assistant Secretary, Bond COLORADO ALL - PURPOSE ACKNOWLEDGEMENT State of Colorado ) ) ss. County of MM. On MA t,� rsYo (p , before me, __l__F--_vt_.. ____n , a Notary Public, in and for said state, personally appeared et VW] A 1P-k04z , personally known to me (or proved to me on the basis of satisfactory evidence) to be the person whose name is subscribed to the within instrument and acknowledged to me that they executed the same in their authorized capacity, and that by their signature on the instrument, the person, or the entity upon behalf of which the person acted, executed the instrument. WITNESS my hand and official seal. (SEAL) MyCommission Expires 04!07@09 Signature of Notary Public 5F5 South Puget Sound 1106 54 Avenue East Tacoma WA 98424 BASE PRICE: $33,880.00 SFS ESTIMATOR: WALLY REEVES This proposal Is based upon the following: SMITH FIRE SYSTEMS, INC. Email: www.smithfire.com (253) 926 1880 Phone (253) 926 2350 Fax PLEASE CALL ME IF YOU HAVE ANY QUESTIONS. FIRE SPRINKLER BID PROPOSAL PROJECT NAME: ANDOVER PARK EAST -BFP UPGRADE DATE: 6/30/06 ADDRESS: 1085 ANDOVER PARK EAST PAGE: 1 OF 1 CITY / COUNTY TUKWILA SPEC SECTION: FIRE SPRINKLER - BACKFLOW BIDDING TO: PROLOGIS, INC. FAX NO.: 253 -859 -1809 ATTENTION: JULIE CHAN ESTIMATE NO.: 7106 -0612 E -MAIL wreeves ©smithfire.com *10274 PAGE: 1/1 North Puget Sound Email: www.smithfire.com 3813 168 Street NE Ste. 1 (360) 651 -7701 Phone Arlington WA 98223 (360) 651 -2419 Fax SALES TAX INCLUDED: ❑ YES 13 NO APPROVALS CITY TUKWILA COUNTY INSURANCE OTHER SMITH FIRE SYSTEMS WILL PROVIDE THE DESIGN, MATERIALS, EQUIPMENT AND INSTALLATION LABOR TO INSTALL A NEW DOUBLE DETECTOR CHECK VALVE (DDCVA) TO THE EXISTING FIRE UNE ONLY. ALL WORK WILL BE INSTALLED PER THE CITY OF TUKWILA DEPARTMENT OF PUBLIC WORKS REFERENCE DETAIL WS-15 (20F2). SFS WILL REMOVE THE EXISTING CONTROL VALVES, SINGLE CHECK AND PIPING IN THE EXISTING VAULT THEN WE WILL INSTALL A NEW VAULT NEXT TO THE EXISTING VAULT. THIS QUOTE INCLUDES THE FOLLOWING ITEMS, 8' DDCVA, ALL TAMPER SWITCHES, 8' NRS VALVE FOR PIV, MODEL 4484 CONCRETE UTILTY VAULT AND ALL PIPING AND FITTINGS FOR A PROPER INSTALLATION. CLARIFICATIONS: 1) PERMIT FEES ARE IN INCLUDED BASED ON CURRENTLY PUBLISHED SCHEDULES. 2) SFS WILL PROVIDE A BACKHOE AND OPERATOR FOR VAULT INSTALLATION. 3) SOME LANDSCAPING WILL NEED TO BE REMOVED DURING THE CONSTRUCTION PHASE, ANY REPAIR OR REPLACEMENT IS TO BE BY OTHERS. 4) SFS WILL USE THE SERVICES OF A UTILITY LOCATOR TO LOCATE ANY EXISTING UNDERGROUND PIPING, ANY REMOVAL OR RELOCATION OF BURIED OR HIDDEN ITEMS WILL BE AT AN ADDITIONAL COST. 5) ALARM WORK OR ELECTRICAL WIRING IS NOT INCLUDED. r ACCEPTEDBY DATE NAME TITLE S(Dallc. 1 Mi1Cc CusicK 10. IUVb 0:71HM Merit Mechanical, Inc. No. NU]] P. 1 PROPOSAL Page 1 17473 Merit Mechanical, Inc. PO Box 2109 Redmond, WA 98073 -2109 Phone: 425 883 -9224 Fax: (425) 887 -0962 mI JDLIE CHAN JULIE CHAN PROLOGIS 23215 66TH AVE SOUTH KENT, WA 98032 ' mono (253)520 -0244 Fax (253)859 -1809 Dat" 07/26/2006 a"b aama/ JULIE CHAN Location PROLOG'S ANDOVER PARE EAST BUILDING 1071 -1097 ANDOVER PARK EAST SEATTLE, WA 98188 mono (253)520 -0244 Po • sax (253)859 -1809 PROJECT DESCRIPTION: PART 1: Domestic Water Supply Install a new 2" Reduced Pressure Assembly on the water service just after the city water meter. See cut sheet Due to apace constraint, the device will be installed to the south where there is ample space. Excavate for supply to and from RPPA, connections to main water supply, Depth of trench will be 18" to 24" depending on depth of existing water supply to fire prevention system. Pour a new concrete pad for the device and hot box, Provide and install a new "Hot fox to insulate the new device and piping, Prior to installation and or excavation, a plan review by the City of Tukwila is required. Provide permit and backflow certification. PART 2: Deduct Meter Provide and install a new Sensus ECR - WP deduct meter which will replace the existing meter located on the irrigation supply. THIS PROPOSAL INCLUDES: Labor and materials, Plan review and permit, Certification of RPPA, Excavating and Backfilling, Follow Specifications and requirements provided by Julie Chan as well as City of Tukwila, Set removed sod in place, Any remaining product to be hauled off site. Work to be complete during normal business hours, 8:00 AM to 4:00 PM. THIS PROPOSAL EXCLUDES: Sales Tax, Electrical supply to Hot Box, Unforeseen obstacles (irrigation, electrical), Guarantee on connections to existing piping, Relocating water supply to fire system, Repairs to any water cooled units or water supplied fixtures on or within building or buildings. (Continued) PROPOSALNO. 17473 Page 2 Merit Mechanical. Inc. ? PO 8= 2109 Redmond, WA 98073 -2109 < ;u Phone: (425) 883.9224 Fax: (425) 887-0962 "'attic CHAN JULIE CHAN PROLOGIS 23215 66TH AVE SOUTH RENT, WA 98032 Dat0 07/26/2006 PO • Job / Leeatioa JULIE CHAN PROLOGIS ANDOVER PARR EAST BUILDING 1071 -1097 ANDOVER PARK EAST SEATTLE, WA 98188 mono (253)520 - 0244 rax (253)859 -1809 Them. (253)520 - 0244 Iva: (253)859 -1809 Sight Thousand Two Hundred Sixty Dollars and 00 cants $8,260.00 Payment to be made as follows: HOST= nn0Q3S3 2ILLII7re MST 30 D71ze, VIXst BALAMCS MT 30 Da29 ref a1VOIC2) 1 3/41 • •• • - ST CMG= ) = Ca Ws PAST WE anDLWTS. 01E nu watt Oa ALL IIDOMIMSbIP AID MITLAaLS. IaYUTCLVPS9 S.VXI ! 01, ALL ?47I9ffi!, PWeS, QALY!S. MD CONDOM PC w.n*n Oa ANT IaPZADVi Oa =NM I= FROVI0.-D DT 07MM. 10 ewe= ow ea DIQ]T1am Zama] T, euera, ITPTC SYS7M. ADM, Oa COWnOLI. Authorized Signature gna ....A. wet ,m1 1 Submitted By: Jim Perkins Mot*: This propos may be witadrawa by us it not I -• - -. i th i n 30 days Acceptance of Proposal Date of Acceptance: Signature Aie -- Print Nana Y 1 - jut. Lo, ZUUO d:)IIM Merit Mechanical, Inc. No. 8811 P. 3 June 22, 2006 Julie Chan 23215 66 Av S Kent WA 98032 RE: CORRECTION LETTER #1 Development Permit Application Number D06 -207 Industrial Caster, Co. —1085 Andover Pk E Dear Ms. Chan: This letter is to inform you of corrections that must be addressed before your development permit(s) can be approved. All correction requests from each department must be addressed at the same time and reflected on your drawings. I have enclosed comments from the Public Works Department. At this time the Building, Fire, and Planning Departments have no comments. Public Works Department: Joanna Spencer, at 206 431 -2440, if you have questions regarding the attached memo. Please address the attached comments in an itemized format with applicable revised plans, specifications, and/or other documentation. The City requires that four (4) complete sets of revised plans, specifications and/or other documentation be resubmitted with the appropriate revision block. In order to better expedite your resubmittal, a `Revision Submittal Sheet' must accompany every resubmittal. I have enclosed one for your convenience. Corrections/revisions must be made in person and will not be accepted through the mail or by a messenger service. If you have any questions, please contact me at (206) 433 -7165. encl File No. D06 -207 P:VennifetCorrectioo Lepers\2006\DO6-207 Correction It 111.DOC jem City of Tukwila Steven M. Mullet, Mayor Department of Community Development Steve Lancaster, Director 6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone: 206 - 431 -3670 • Fax: 206- 431 -3665 DATE: PROJECT: (P:Laurie Adminnoanna/Comments 006 -207) PUBLIC WORKS DEPARTMENT COMMENTS www.ci.tukwila.wa.us Development Guidelines and Design and Construction Standards June 7, 2006 Industrial Caster, Co Tenant Improvement 1085 Andover Park East REVIEW #: 1 PERMIT NO: D06 -207 PLAN REVIEW: Contact Joanna Spencer at (206)431 -2440 if you have any questions regarding the following comments. 1) The City has determined that the multiple tenant building where Industrial Caster, Co will move in has deficiencies on the domestic water supply, fire prevention, and irrigation lines. a) Domestic Water A Reduced Pressure Principle Assembly (RPPA), previously called a Reduced Pressure Backflow Assembly (RPBA), shall be installed immediately downstream of the permanent water meter. Installation at another location requires the Public Works Director's approval. The RPPA shall be installed in a Hot Box/Hot Rock or equal freeze protection enclosure anchored to a minimum 4" thick concrete pad. Public Works strongly recommends a power supply for the freeze protection enclosure. Please specify backflow size, manufacturer, and model no. on plans and resubmit a cut sheet. b) Fire Line The existing 8" Detector Check Valve Assembly is a single check and shall be replaced with a Detector Double Check Valve Assembly (DDCVA) per City of Tukwila Detail WS -15 (2 of 2). Please note that on a retrofit fire line backflow prevention design, the plans must be stamped, signed, and dated by a Level III certificate of competency holder or by a professional engineer registered in Washington State. c) Landscape Irrigation The existing 1.5" irrigation deduct water meter shall be upgraded with a Sensus ECR- WP register that is compatible to the Invensys automatic reading system and register ring, no radio required. I have enclosed Development Bulletin C5 that describes the design and installation requirements for cross connection control. A separate letter was mailed to the building owner representative, Prologis, Inc., on 06/07/06. The Public Works Director will withhold issuance of this Tenant Improvement permit until the Permit Center receives plans for items la, lb, and lc or a bond for 150% of the design and installation cost of subject devices, together with a letter stating the installation by a certain date. 2) Due to increase in plumbing fixtures please submit a King County Metro Non - Residential Sewer Use Certification. Form is attached. ACTIVITY NUMBER: D06 -207 PROJECT NAME: INDUSTRIAL CASTER SITE ADDRESS: 1085 ANDOVER PK E DATE: 08 -01 -06 Original Plan Submittal Response to Incomplete Letter #_ X Response to Correction Letter # 1 Revision # before Permit Issued DEPARTMENTS: Building Division ❑ Public Work < i e I LO PERMIT COORD COPY PLAN REVIEW /ROUTING SLIP Fire Prevention DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete Comments: APPROVALS OR CORRECTIONS: Documents/routing slip.doc 2-28-02 Planning Division Structural ❑ Permit Coordinator ❑ Incomplete ❑ Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: TUES/THURS ROUTING: Please Route E] Structural Review Required ❑ No further Review Required ❑ REVIEWER'S INITIALS: DATE: DUE DATE: 084-06 Not Applicable ❑ DUE DATE: 0841 -06 Approved ❑ Approved with Conditions Not Approved (attach comments) ❑ Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: ACTIVITY NUMBER: D06 -207 PROJECT NAME: INDUSTRIAL CASTER, CO. SITE ADDRESS: 1085 ANDOVER PIC E DATE: 06 -05 -06 X Original Plan Submittal Response to Incomplete Letter # Response to Correction Letter # Revision # After Permit Issued DEPARTMENTS: 61( A, ,,� f Building Division p " I-ire Prevention Pkblic Work Structural ( CO 5- diAA i P (e -1-o4 DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete Comments: Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: TUES/THURS RO9TING: Please Route Structural Review Required REVIEWER'S INITIALS: APPROVALS OR CORRECTIONS: Approved ❑ Approved with Conditions ❑ Not Approved (attach comments) Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only q rt n CORRECTION LETTER MAILED: LUl Y�W Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ Documents/rouling slip.doc 2.28 -02 PERMIT COORD COPY PLAN REVIEW /ROUTING SLIP Incomplete ❑ No further Review Required DATE: XI& 6 P al nning Division It Permit Coordinator DUE DATE: 06-06-06 Not Applicable ❑ DUE DATE: 07-04 -06 Staff Initials: Date: 1 13 I I o6 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tulwila.wa.us Plan Checic/Permit Number: D06 -207 ❑ Response to Incomplete Letter # ® Response to Correction Letter # 1 ❑ Revision # _ after Permit is Issued ❑ Revision requested by a City Building Inspector or Plans Examiner Steven M. Mullet, Mayor Steve Lancaster, Director Revision submittals must be submitted in person at the Permit Center. Revisions will not be accepted through the mail, fax, etc. Project Name: Industrial Caster, Co. Project Address: 1085 Andover Pk E Contact Person: Julie Chan Phone Number: an 3 C20 - 02 Summary of Revision: 13 Ot4. el at t esc;es J -7 , - Received at the City of Tukwila Permit Center by: co Entered in Permits Plus on pplications ones -app icanons on line revision submittal Created: 8 -13 -2004 Revised: cOver C0 GOnnec t rot -t. PW leiter comrn cs4s (n Sheet Number(s): "Cloud" or highlight all areas of revision including date of revision Iy V `41 License Information License SIERRCC145N8 Licensee Name SIERRA CONSTRUCTION CO INC Licensee Type CONSTRUCTION CONTRACTOR UBI 600634891 Ind. Ins. Account Id Business Type CORPORATION Address 1 19900 144 TH AVE NE Address 2 City WOODINVILLE County KING State WA Zip 98072 Phone 4254875200 Status ACTIVE Specialty 1 GENERAL Specialty 2 UNUSED Effective Date 8/28/1986 Expiration Date 3/31/2008 Suspend Date Separation Date Parent Company Previous License Next License Associated License Business Owner Information Name Role Effective Date Expiration Date COLLINS, ROGER D 01/01/1980 COLLINS, KIMBERLY J 01/01/1980 Look Up a Contractor, Electric;afl or Plumber License Detail Page 1 of 3 Washington State Department of Labor and Industries General/Specialty Contractor A business registered as a construction contractor with L &I to perform construction work within the scope of its specialty. A General or Specialty construction Contractor must maintain a surety bond or assignment of account and carry general liability insurance, Bond Information Bond #7 Bond Company Name SAFECO INS CO OF AMERICA Bond Account Number 576739 Effective Date 08/26/2001 Expiration Date Until Cancelled Cancel Date Impaired Date Bond Amount S12,000.00 Received Date 07/30/2001 https: // fortress .wa.gov /lni/bbip /printer.aspx ?License= SIERRCC145N8 08/07/2006 x x x x