Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Permit 5748 - Joslyn Building - Tenant Improvement
CITY OF TUKWILA BUILDNG PERMIT (POST WITH INSPECTION CARD AND PLANS IN A CONSPICUOUS LOCATION) Department of Community Development - Building Division 6200 Southcenter Boulevard, Tukwila WA 98188 (206) 433 -1849 BUILDING PERMIT NO. 5 1 DATE ISSUED: 401 Baker B1 FEES DESCRIPTION AMOUNT RCPT • DATE BUILDING PERMIT FEE .:. i i F bUJ aI �.1Q�'.4 8 28 -89 1. ' ::- PLAN CHECK FEE 381.00 BUILDING SURCHARGE ENERGY SURCHARGE WA. ST. CONTRACTOR'S LICENSE # ERANDC2211JP EXP. DATE 8-17-90 OTHER: Owner PHONE OCC. LOAD TOTAL. - 971.50 ZIP 2,080 PLAN CHECK #89 -234 P11OJf C T IFJF OIlI'u \ nor us reN 88,000.00 PROJECT NAME/TENANT #t Joslyn, Building ASSESSOR ACCOUNT 022310 -0 85 -0 TYPE OF 0 New Building U Addition LXl Tenant Improvement (commercial) U Demolition (building) U Grading/Fill WORK: 0 Rack Storage O Reroof 0 Remodel (residential) 0 Other DESCRIBE WORK TO BE DONE: Demo existing 1,500 square feet office, construct new 4,000 square feet office, increase parking to comply, add required landscaping and irrigation. PROPERTY OWNER Alvin Pparl PHONE 244 -2600 ADDRESS 405 Baker Boulevard. Tukwila. WA ZIP 98188 CONTRACTOR E. R. Andersoi Company PHONE 453 -8717 ADDRESS 120th Avenue N.E. , Building #2, Suite 217, Bellevue, WA ZIP 98005 WA. ST. CONTRACTOR'S LICENSE # ERANDC2211JP EXP. DATE 8-17-90 ARCHITECT Owner PHONE OCC. LOAD ADDRESS TOTAL OCC. LOAD ZIP USE 4 Office / 8 -2__ ow oom arP�iou� B-2 CODE cOr.it't / Other B -2 IArICt Confer./B-2 Warehousi B -2 Yes O N o (through Public Works) FLooR 1 SQUARE FEET oCC. LOAD SQUARE FEET OCC. LOAD . SQUARE FEET OCC. LOAD SQUARE FEET OCC. LOAD SQUARE FEET OCC. LOAD TOTAL SQUARE FEET TOTAL OCC. LOAD 1st 2,080 21 1.128 11 529 0 306 , 20 13,765 28 11,808 80 TOTAL. 17,808 80 TYPE OF CONSTRUCTION: Il -N UBC EDITION (year) 88 SETBACKS: N _ S — E — W — FIRE PROTECTION: �Sprinkiers 0 Detectors 0 N/A UTILITY PERMITS REQUIRED Yes O N o (through Public Works) ZONING: C -MBAR /LAND USE CONDITIONSOYes ®No Landscaping CONDITIONS (other than those noted on or attached to permit/plans): APPROVED FOR ISSUANCE BY: BUILDING OFFICIAL DATE: I hereby certify that I have read and = 'mined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating const the pe I am authorized to sign for and obtain this building permit. ■1%41■111144i...LINIAI SIGNATURE DATE: PRINT NAME: ‘")�t $ �L �+t�/�tit) 5 4 COMPANY: E. ' . _ Pc-4) (. t.51/4.4%) This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. CERTIFICATE OF OCCUPANCY NO. DATE ISSUED: VOf 1 aW � e BUILDING PERMIT APPLICATION TRACKING PLAN CHECK NUMBER 'WQ3L) PROJECT NAME SITE ADDRESS 13v■ Wie �.J SUITE NO. LI OI -2;-er E31 INSTRUCTIONS TO STAFF • Contacts with applicants or requests for information should be summarized in writing by staff so that any time the status of the project may be ascertained. • Plan corrections shall be completed and approved prior to sending on to the next department. • Any conditions or requirements for the permit shall be noted on the plans or summarized concisely in the form of a formal letter or memo, which will be attached to the permit. • Please fill out your section of the tracking chart completely. Where information requested is not applicable, so note by using "N /A ". BUILDING SQUARE FOOTAGE/OCCUPANCY INFORMATION (to be filled out by Plan Checker) 41110z ? SQUARE- . FEET LOAD SOUARE OCC. SQUARE OCC. FEET LOAD FEET LOAD tinF SQUAR FEET OCC. LOAD ARE FEET LOAD TOTAL SOUARE FEET TOTAL OCCU- PANCY LOAD DEPARTMENTAL REVIEW "X" In box Indicates which departments need to review the project. Wge BUILDING - initial review FIRE %PLANNING O PUBLIC WORKS de S.M . Oat 13'63-6q (ROUTED) 11111 0 ON: [ 'p►Inkier* J 1 Detectors () WA �,m FIRE DEPT. LETTER DATED: I22 i INSPECTOR: g17,, INIT: 2ONING: —v - - D USE CONDITIONS? • Yes :. • g REFERENCE F E NOS.: , / .// �" -r 'MN INIT: MINIMUM SETBACKS: N- S- E INIT: O BUILDING - q..26-8? 1-27 a.'7 final review INIT: ,��. -� VN 600<, 1 '18E3 REVIEW COMPLETED PERMIT NO. - CONTA TED DATE READY DATE NOTIFIED `"l _ sq )) Bn:) i3 PERMIT EXPIRES 2nd NOTIFICATION BY: (init.) AMOUNT OWING t G- �9 () . 5Q NOTIFICATION BY: (snit.) CITY OF TUKWILA Department of Community Development - Building Division 6200 Southcenter Boulevard, Tukwila WA 98188 (206) 433 -1849 BUILDII'i3 PERMIT APPLICATION PLAN CHECK NUMBER '1 I'I'L I C J T ION (11LJ T L3L. T /1.1 I=T) CUT COAIPLE TEL Y FEES (for staff use only) DESCRIPTION :;: BUILDING PERMIT FEE.... RCPT::: #: DATE PLAN .CHECK :FEE :. BUILDING SURCHARGE ENERGY SURCHARGE OTHER: TOTAL`' • SITE ADDRESS . SUITE # /lo ( .D/A.EtZ vi). VALUE OF CONSTRUCTION - $ 8� OC)C� 1 PROJECT NAME/TENANT ASSESSOR ACCOUNT # .JUSL- J 1l l t)w� C�F>�rc i riot (1-ieziluio iii( ,DIAL Q ..z 5 I 0 - oO 6 5 - TYPE OF U New Building U Addition `Tenant Improvement (commercial) U Demolition (building) WORK: 0 Rack Storage O Reroof D Remodel (residential) O Other DESCRIBE WORK TO BE DONE: DEMO Es -i'1lLA % 1'-,0O npPtL,g. LokisTeua- MEW 40m sF yr -=its T 1�r�l E P)2.16 l o (DM .R.>?/ Abb DEL 11/ L111..19S6APE * .re)?. . BUILDING USE (office, warehouse, etc.) 0 ri✓ir.. 4,0 64 sr ; t,(f`AiZt= MUUSI✓ I .6;71D5 ter= NATURE OF BUSINESS: 47,1 * Ai me: Ji(-tAL - 1A hLY 4LL- cX sr-' pF atosmfiv _ CIDT llluL WILL THERE BE A CHANGE IN USE? L9-No U Yes IF YES, EXPLAIN: SQUARE FOOTAGE - Building: I/ floe, Tenant Space: ALL Area of Construction: 4 U WILL THERE B STORAGE OR USEI OF FLAMMABLE, COMBUSTIBLE OR HAZARDOUS MATERIALS IN THE BUILDING? No 0 Yes IF YES, EXPLAIN: PROPERTY OWNER AL1' Q A L PHONE '2 44 - 'ZGoo ADDRESS 40s- bKl✓a x..Vt l '77i .LU1lo, li) 'CONTRACTOR E. K. AtJt ElaSon ZIP93 `0e) PHONE X4s. °�,-7 l 7 ADDRESS 3003 1'ZQt-4. AVE kJ. C. 13LDto #Z CATE 2.17 ELI VUt. W!v z I R9Saa ar WA. ST. CONTRACTOR'S LICENSE # E AND . ZZ ( N P EXP. DATE 9, l `l - „ ARCHITECT C)Wf �. PHONE ADDRESS ZIP BUILDING OWNER OR AUTHORIZED AGENT SIGNATURE .--' PRINT NAME .p�..� . �C /c /fir/ c b ADDRESS j) _(26(-41 > Ala- ! (04'Z SATE "Z1l CONTACT PERSON RlC..k.. g.cLEtzT CITY /ZIP& , 96Dos PHONE4 3.. 57 t 1 APPLICATION SUBMITTAL In order to ensure that your application is accepted for plan review, please make sure to fill out the application completely and follow the plan submittal checklist on the reverse side of this form. Handouts are available at the Building counter which provide more detailed information on application and plan submittal requirements. Application and plans must be complete in order to be accepted for plan review. VALUATION OF CONSTRUCTION Valuation for new construction and additions are calculated by the Department of Community Development prior to application submittal. Contact the Perrnit Coordinator at 433 -1851 prior to submitting application. In all cases, a valuation amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Building Division to comply with current fee schedules. BUILDING OWNER / AUTHORIZED AGENT If the applicant is other than the owner, registered architect/engineer, or contractor licensed by the State of Washington, a notarized letter from the property owner authorizing the agent to submit this permit application and obtain the permit will be required as part of this submittal. EXPIRATION OF PLAN REVIEW Applications for which no permit is issued within 180 days following the date of application shall expire by limitations. The building official may extend the time for action by the applicant for a period not exceeding 180 days upon written request by the applicant as defined in Section 304(d) of the Uniform Building Code (current edition). No application shall be extended more than once. If you have any questions about our process or plan submittal requirements, please contact the Department of Community Development Building Division at 433 -1849. DATE APPLICATION ACCEPTED Blasrl R4 DATE APPLICATION EXPIRES SIiiiMITTAL CHECKLIST COMMERCIAL `NdW:R�N tAMIN.ElICIAC TEM1l1�f 1�1PitOVEMENn1 nt'.Nui • 2 ),,,Ostitti ofli stata iii Wei�h(oton 8t0e No oii *aUabr* ................... apoNcabon., tad buikliny peri moor.A ou tNuitl ans,.wfd :Bt+iidn :flooi: " ati:a . NNNSATELUTEM10HE lllkip penit', Ocourit• S(ia Plan'IRtiiiwino`buildina.a loceiici otantenrieVtaEelliie enpinstr mayaw roquI id *on ton ista:goeng ompleted buikinp permit appNcadon Rorie for each awctur r Aocou t N .440 . dgscnb(rip ex strop roof, ptsnd bernp �emovad, � l ve boinp,lnstallad ::....:.. 'CITY OF TUKWILA Building De l ment 6300 Southc r Boulevard Tukwila, WA 8188 • (206) 431 -3670 woxItiwkstoceasnAlizetmm.samoider44nroximorrkweatelatigacalMa INSPECTION RECORD PERMIT # 61;08 Date Type of Inspection ��„� Date Wanted -- Ley 6 a.m. Site Address p� �� d Project J a 4 „z ZVI Requestor Phone # Special Instructions Inspection Results /Comments: Cr ok- 9o- oTh Inspector Date 7-23 -- CITY OF TUKWILA Building Division 6200 Southcenter Boulevard Tukwila, Washington 98188 (206) 433 -1849 Type of Inspection .e_i /i ?9 3ri d Site Address "-/CJ ab)d. Requestor /11; r_Ja c. AA. Pc-r r— C E.e. /4,icicrrc C a , ) Special Instructions INSPECTION RECORD. PERMIT # Date Date Wanted //-07--?? Project 500 /.n aug. Phone # /3 /- .5.369y P.m Inspection Results /Comments: Inspector Date CITY OF TUKWILA Building Division Tukwila,�tWashington Boulevard 98188 (206) 433 -1849 INSPECT N RECORD. PERMIT # Date Type of Inspection Wi.\\ bO 1f d • Site Address 40\ E o.k-er 1 Requestor 1111 %,,L,, Date Wanted 1 (,1' 7- .m p.m Project b1. 3 Y1 6U l l 1flcj Phone # LS 1 f53 () 5 Special Instructions Inspection Results /Comments: C�''Q.)6 5(7-e-n.4,� ".per- /62 S r` (`vr "( I ok (ic, 'bate. r3Ytd ko,d T bse netn+nus 17/5-ti,i1 natal / Arta m1100- ovena...n mwwa, ws io."...'.....m.....n.+....«+.... ,.......4 nw...r.+..wmwviatw.xiaM. aroicetmaeae,YSnt'n wi�srr.a: traniitrY ta.M.Yeiwfr.VAliMbbiti•G At4,^:311'1,ftti9r,6xfi....`�' ?��I�. CITY OF TUKWILA Building Division Tukwila,,tWashington Boulevard 8188 (206) 433 -1849 Type of Inspection 6ti8 Site Address 9,0% Ae Requestor /l4 Special Instructions INSPECTION RECORD PERMIT # A7 Date il.-- l,S ---g9 Date Wanted /f —/ -- Project tjb gv7 !� AI 4, 7/ Phone # 27/3 -5-) ( y Inspection Results /Comments: /x(o f' G (tocdah/e. tw`ie t , /ptelr Inspector Date l �Pff CITY OF TUKWILA Building Division Tukwila,,tWashingtonul98188 (206) 433 -1849 INSPECTION RECORD PERMIT # S>L-tle) Date // -/3-- e l Type of Inspection _/-� S Date Wanted l /h--8 (4. p.m. Site Address 4(0/ 84 zr- - 3/€-1° Project C roc57., /v2 /3t.), u, 27 Requestor 4 G .e Special Instructions Phone # 4/ / -(53 Inspection Results /Comments: Inspector 41,m )2449 Date Gl v/79 CITY OF TUKWILA Building Division 6200 Tukwila,,tWashington u198188 (206) 433 -1849 Type of Inspection Zr\5Wo ' t OY�1 Site Address Ho( eo.ker f3 Requestor r INSPECT RECORD PERMIT # S19 Date 1 - ct' 3: Li Date Wanted I I -13 - (69 a.m p.m Project 1/43- an 6Ull 1r, Phone #) _ 5-5(0 Special Instructions Inspection Results /Comments: /4/071- d cd TFnr. /1) / //'1 n� +e if-- / I,- CC/ CITY OF TUKWILA Building Division Tukwila,tWashingtonul98188 (206) 433 -1849 '•l '4A2'.wkifwAt,"%.` ,ssItfit3ih.'"wolg iii:,;,: n' "' ` + ., XNt"::zk.. • INSPECTION RECORD %ZS PERMIT # vg- • Date / / /7jel +'J. Date Wanted / //8' (�jl� p.m. Type of Inspection /7-dh -i; D- h'e'r / • -. e-' Site Address Requestor Special Instructions 4 / eaAee.- ,d/07/, Project Ms ly 1i 4'S /4i Phone # Inspection Results /Comments: Inspector Date // O -g 7 :. d Ai°.vGiiymmulwavli 'i:i'Sh'3eS.M*S hootko,- ;Y::a.Yis:d 1.4,;...m vz4.:4+rYis:I:M!ki CITY OF TUKWILA Building Division 6200 Southcenter Boulevard Tukwila, Washington 98188 (206) 433 -1849 Type of Inspection Pet, j;• Site Address go/ Requestor M G■X• reek ( $ rea Special Instructions INSPECTION RECORD PERMIT # S `/ Date `d — 26 -c Date Wanted JO-- 2 4- 6, Project 705 6,'1 Phone # P.m Inspection Results /Comments: Inspector CITY OF TUKiLA Central Permit System &,./ntrol No. Permit No.. 7 Y7 FINAL APPROVAL FORM TO: El Building El Planning ❑ Public Works Fire Dept. El Police El Parks/Recreation Project Name 7:� s may. 7 �,f, 71,1 Address / � � 4. %' �-'• Type of Permit(s) % l This project is nearing completion. Please investigate your area of responsibility and indicate below either your final approval or necessary corrections. If no response is received within one week, it will be assumed that the project is of no concern to your department and a certificate of occupancy may be issued. This project is NOT approved by this department; the following corrections are necessary: () () () () () () () () () ) ) ) Authorized Signature Date This project is approved by this department: frpe, 573 \ Authorized Signature / 877 Date CP8 Form 3 / Citlitof Tukwila 6200 Southcenter Boulevard Tukwila Washington 98188 (206) 433 -1800 Gary 1. VanDusen, Mayor Plan Check 089 -234: Joslyn Building 401 Baker 81 THE FOLLOWING COMMENTS APPLY TO ND OME PART OF THE APPROVED PLANS UNDER TUKWILA BUILDING PERMIT NUMBER__- j_�Li BE __. 1. No changes will be made to the plans unless approved by the Architect and the Tukwila Building Division. 2. Plumbing permit shall be obtained through the King County Health Department and plumbing will be inspected by that agency, including all gas piping (296- 4732). 3. Electrical permit shall be obtained through the Washington State Division of Labor and Industries and all electrical work will be inspected by that agency (872 - 6363). 4. All mechanical work shall be under separate permit through the City of Tukwila. 5. All permits, inspection records, and approved plans shall be posted at the job site prior to the start of any construction. 6. Any new ceiling grid and light fixture installation is required to meet lateral bracing requirements for Seismic Zone 3. 7. Partition walls attached to ceiling grid must be laterally braced if over eight (8) feet in length. 8. Any exposed insulations backing material to have Flame Spread Rating of 25 or less, and material shall bear identification showing the fire performance rating thereof. 9. All construction to be done in conformance with approved plans and requirements of the Uniform Building Code (1988 Edition), Uniform Mechanical Code (1988 Edition), Washignton State Energy Code (1989 Edition), and Washington Stae Regulations for Barrier Free Facility (1989 Edition). 10. Validity of Permit. The issuance or granting of this permit or approval of plans, specifications and computations 'shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of this code or of any other regulation or ordinance of this jurisdiction. No permit presuming to give authority to violate or cancel the provisions of this code shall be valid. 1908 City o Tukwila FIRE DEPARTMENT 444 Andover Park East Tukwila, Washington 98188 -7661 (206) 575 -4404 Gary L. VanDusen, Mayor September 22, 1989 Fire Department Review Control Number 89 -234 Re: Joslyn - 401 Baker Blvd., Tukwila, Wa. Dear Sir: The attached set of building plans have been reviewed by The Fire Prevention Bureau and are acceptable with the following concerns: 1. Maintain fire extinguisher coverage throughout. 2. Exit hardware and marking must meet the requirements of Uniform Fire Code Sections 12.104 & 12.114. Exit doors shall swing in the direction of exit travel when serving an occupant load of 50 or more. (UBC 3303) (UFC 12.101) Exit doors shall be openable from the inside without the use of a key or any special knowledge or effort. (UFC 12.104b) Exits shall be illuminated at any time the building is occupied. An emergency system shall automatically provide exit illumination upon failure of the main power supply. (UFC 12.113a) 3. All sprinkler drawings shall be prepared by companies licensed to perform this type of work. Drawings shall first be approved by the Washington Surveying & Rating Bureau, Factory Mutual Engineering or Industrial Risk Insurers, then by the Tukwila Fire Department. No sprinkler work shall commence without approved drawings. (City Ordinance #1141 & NFPA 13, 1 -9.1) (UFC 10.307) Maintain sprinkler protection for all enclosed areas. (NFPA 13, 4- 1.1.1) (UFC 10.302) City oC Tukwila FIRE DEPARTMENT 444 Andover Park East Tukwila, Washington 98188 -7661 (206) 575 -4404 Gary L. VanDusen, Mayor Page number 2 Contact the Tukwila Fire Department, Fire Prevention Bureau to witness all required inspections and tests. (NFPA 13, 1 -10.2) (UFC 10.307) 4. All electrical wiring is to be inspected by the State Electrical Inspector, Washington State Department of Labor & Industries. (UGC 10.104) Each circuit breaker shall be legibly marked to indicate it's purpose. (NEC 10 -22) (UFC 10.104) All electrical work and equipment shall conform strictly to the standards of the National Electrical Code. (NFPA 70) (UFC 10.104) 5. All required occupancy separations, area separation . walls, and draft -stop partitions shall be maintained and shall be properly repaired, restored or replaced when damaged, altered, breached, penetrated, removed or improperly installed. (UFC 10.401) All wall and ceiling materials constructed of wood, shall be fire retardant treated. (UFC 10.401) All interior wall covering materials shall be fire - resistive or shall be treated to be fire - resistive, so as to result in a flame- spread rating as required by UFC Appendix VI -C tables 42A and 42B. A certificate of the flame spread rating is required to be delivered to the Tukwila Fire Department. (UBC 4204) (UFC 10.401) E R ANDERSON General Contractors 1.20E-453.8717 LIC. NO. ER•AN•DC•221 NP .. Seetember. .:e0.' 1989 City of Tukwila Duane ° Griffin Department of Community Devel.opmen- Tukwi "1 a, Wa. 98188 Concerning: our telephone :conversation .regarding approval of a temporary office trailer Pt 401 Baker Blvd.- fh;e size' we propose ` is 10 >t 52', , supplied . by; Atco Structures of `'Vent. They,. will: level, and block: the trailer "and supply (2): UE4C aPPr.aved stair and hand rail sets. We wi 11 'r.emove the trail er at th:e ..end ; of ;,the tenant a mprovement; or at. ( 10) weeks;' whff ch ever i.s sooner . Thank you -very .much.for';your. decision Ltse., i t makes our. a ob, much ease Ric,hard..L. ;F:ebert,:. F'ro iect ' Manager .:: E. R. Eriderson Company-` • q..19/z01 R;c�C E � �ytcleY`5cm 653 -c37l7) Cct��ecf I'r'o knd� � � -thy eou ��f U.Se (� 1 � X yQ 'h'1U (oi �2 as a _*e7yiconarYI �{'��ce �'or 3 pe,o9ie u1�i;le liQy doof .rVl4. 6-�ice. � QCe , e 15 Sore 1r-n ?iC cm _�k32.r �IJ� (1iex/ coo12r r I��cum), fl1e\/ woul� use +iis 4e22orary oTh<e IO cJee kp Ike reiroc(e( uJoulcf inclu e reyyic�de(i�, ?��¢ exi5trV res�rda,yns iike. ex�sfr 1 ecm�pa y e�poyees (�O u ie 15 `?'� haihr6o-yrt Art. i 601/1 i 7_5124 fAe 1r'/ r hXd(-ng o ua %e. pa,200 oil 0. week iy 5-; i Z :b/d hr-M4 uJOcdc.1 Or >O 417, 0mc( _5'o�eo�e G�14u(d :ref ,�X2c/t__ .�a {�,'in Sv Ae)ter to it kak Tack T o(d _ :Rjck ..? -(4. _+ is cootild ot //ow ect r . yce j u.es c1 irtooic(e us c� . e �.Y _ : le ad- izc(ted . 4c . f - oz p f jicaiL?'art 5`7Q4,1 'ftke j pe + 5'i2.e cDP. ffct ,. irat ►'/er; at 5144 /elve7r1. Oaf /2(741. . ffrr6, k ,Ct.rJ(- I t " d. '''.uaYC(YQc`/s. c,�tli .Ae ivis /affeC( oil . rCt leY.. Ae. .. Q s use tlnai• i - )1, 1 yet I I•e r (-01 l l.. cm I, t u6ecL u -. i'1.......11_. i s 4ecf _ pr .'dr.....(14. 0( uovt. 07V ...1,0 c ee.)1s_v ..v)l11 lt.e.0 ....,s...1.ego ick Rebe 900 120TH • BLDOts M2; SUITE 217?'; SEI.I.EYUE;.WA,9800$. // 110 E.-410ST ■■•3 G. BM) G, 17,9,09, 13' tIFF-% 404-3 0 0 a :t7 I ESTIb.J 7 9 op9N 1. I o' I I .5' C 1 C.. 22. C. ,t) C. ,LO -1 C. 19 C...%4I IG I.5. 1 ,FtoPOseP (-roe.R k.)J1:)C1 OFF' MAT6H L.ANE7-AF1 1 IZSZKIATOKI Llt4E lJ LANbSCAPE' . 1 1 el x C. K (44 I • . eis' = rutA. srts • l•1 ! tifivi • VATatupu, euF 1130VIDE. ale JAR !, • EASM44 JAPA14E,ISE MAPLES 6F' Pgso1Nc, Ww�;�EHo 13765 It t000 14 o�p1cE > sMaw �o*-N 404.3 �, 400 I4 Svc. Btac. 1 ?, SOS 13 'oFFA c.L 4043 °' C z�t i I � MATH LANDxAP5 To 606111.161 Accuf+ -N lAtt>X.ApE rezekqtr losTA.Lea C23 a C Z2, 1 P- 9I0w 1- I E} C,il .5% ciO i � LAN bSCAPE' G 19 1 �I.Vp %e MAPi.E City of Tukwila 6200 Southcenter Boulevard Tukwila Washington 98188 (206) 433 -1800 Gary 1. VanDusen, Mayor .. August 29; 19E19.. Risk:. Rebert F�',h. rand ,r on. [ r: 300. '120th Ave.. N. E.. : Eui.:lcIing. :42.,. Curl e 2.17 - I:re:l..l evc.IE, Ws7 9BOOE' Application #89231:1. Dear :Mr. Reber•: JoslynBui.lding As :noted On the proposed cconstruc..t:Um .pi n , submitted for this , ; tatiil.ding, the pl. anning DePar°tinen•t is requi.r:inc- that a 1 andsc: ape :irrigation. Sys.,•tern be. i.nst-il.1 d as cenditi.or•h•of:'permit approval. A .separate landscape : 1 .rl "'i.gati c r reVieW and permit is required `through the Public Works Department. l: have .,enclosed the. appl i da ion . •Form, : Wlai ch needs to be submitted tca the Fermi t Center wi.'th four (4) ..set > of .pl. gin,' showing' the' system 1. yor.it. I"he l andscap e i rr:i gat i on 'system. must 'be:. installed ..and .si g fled Icy the. lli:i.l.i.ty Inspector prior' .i.ri• .requesting, final'.in pecti.Dn of A :he bui-leiing pcar•mi:t.: -f you s:,hnia1 cl have any questions or eked an y assistance, please •Fec..Al -Free to contact me r t 433-1851. Sincerely,, Zem24 700.1,1AA, Becky L. Davis Permit Coordinator cc: Vernon L.Jmetsu City of Tukwila 6200 Southcenter Boulevard Tukwila Washington 98188 (206) 433 -1800 Gary 1, VanDusen, Mayor Conditions of Approval •(put on plan review letter) Install landscape irrigation system. This separate permit is required through the Permit Center and shall be signed-off by the City Inspector prior to scheduling the final inspection. F'rvvide_ landscaping and parking :per- approved site plan.. Schedule inspection with Vernon Umetsu, Planning Department (43371849).4 'prior to scheduling final inspection. Remove .temporary,off.ice trailer prior to final . building permit inspection.. " ` Mr of Tukwila PLANNING DEPARTMENT 6200 Southcenter Boulevard —Tukwila, Washington 98188 (206) 433-1849 •••••••••■ ORDINANCE COMPLIANCE PLAN CHECK UNIFORM BUILDING CODE, 19&8 Editic Potrriot4_ 401 154KEtz. .eLvD$ -Rs 5•4\e-Jr coot Ltt\A\T6 IX 1-00M. UY1TTWCi b 44M 40USEy__IF ZEIST) E.XAT `FO' exiq. (tV,trr • goosE t (-1.1141;?0:21,4 °5egifft UtAsE 4 OFG OtAKEeS -0\ X1 Feoe, ..14/2a.--LAA-4-44_ WitsE, Natcwrgot 4te4, ceot•top.. 41-41-1FIL (JAIL Cia1 rflA.Aa_14M) J2rain Lo G-0 10441-gS r400 Red E "AErAes sa,ege2S:Rareert-44•T vocestkyr Cu 1p 1cK t-OALetwAE, zegssizz. 43-?r vzii 07 61-8-61 145[7(2._MI1:Zt_a< VElgEe-ti 'ILISa2E)..6EC)1SWES 4-ie -x)tusS CO/CAa4E4 asI6E, 1•40.14Mi -tc) ___/C1/41:clizigALGLAAALAA5_ goz4 VJAAA,_ 011 ata of Tukwila NANIM. o.Aeteir 6903 lame«nw ward - rORM.wartpianvelM aw uo-l1A PLAN CHICK Date: Slaagq File: # iv-a Sheet / of_ ORDINANCE COMPLIANCE CHECKLIST PROJECT • fl %() Uniform Building Code, 19 ill Edition. 1. OCCUPANCY GROUP. 8 "a 2. TYPE OF CONSTRUCTION• 3. LOCATION ON PROPERTY. Lf7/A' 4. BLDG. HT./ NO of STORIES. C41/4 5. FLOOR AREA: 6. OCCUPANT LOAD. Q >F -f-icr. a0'a' lob= 021 (,vh 3c 1_3-hoto room 11 °' 7' goo = 11 Q -fe�r (A Stroon4S,, 5a cr = 0 ttuichi eh ) Cc1f r lee o� :� 15 - are toh d= /3, 7ea5 - Leo = $ 7. EXITING REQMTS. ThAfil Dom^ .; gQ 1Jr.& Q Alija, j: two '6.4 11101-: Ltai iY� -feL purtAtatot DETAILED REQUIREMENTS 2 8. OCCUPANCY: E?1 9. TYPE OF CONSTRUCTION: III 10. ENGINEERING REGS. & REQMTS: Ell. COMPLIANCE w/ W.S.E.C. ® 12. COMPLIANCE w/ Chapter 51 -10 W.A.C. NOTES: 45-0,h athtVsLirk- 9-z 0 TYPtY -c\.1 WAgE Hau se. ,7 -2,44 S. TO PUgLit•i AF52VE. NOT LESS THAN 65' '.\// VVIA/-1/1/VV\R3°/; GE-11.11■161 5-rEsL quE2 c 6r44ia? R-11 416.1-1a 61-Os 0 1 G A af..,P. Li1.17 UHoef3; -- F2Ve 5i55L TUP Z4' CUa TYPE, X 0-11 VUITh G 34" cria E/6" TYPE- Y- AWC,1-102 cs: 631-01 I N' „.....)r.L:TION, 140 cLE GUT iN.1 NEW 5 4' kilt4P1 A ,_c"Fric-E 6040 eetA tiseP)i 30./e/ 1,(F , ALL It-o" CoNFE.r..ENcE 17 0- lb e-o" i-\V) 6E11.0(1 114 ALI- (S) KEST gc--1.-1S.), c:ik1f5 24 CI040NAL re..A3c-1E- TO r.TA(....-E R, St4sP. c-E-10.-461 OFTICE H 6 OMEN LAV N/ E.146WE.- ST"L-L2' H.G. ME14 IA _L if L -77 111- •12 L 12" Is" 6.01)stres, .1441:-.1!``)G. f3'.0 ----- TYF 4 NAZ.E.Hou LE afol,9 3:7 to7 IL FILE COPY i understand that the Plan Check approvals are subject to errors and omissions and approval of plans does not authorize the vielation of any adopted code or ordinance. Receipt of contractor's copy ordcThst 8: ■=111ktik. ,w -••• e ge Date - as Permit No S / SEP 2 1939 GHANa 5)(isTiN DOtiaLE ENtif?-1" PeXe-s TO SI46L-E- _,-/- LcTAL Foot-1 F1ft4KL E2 PCX11 = cd (AaKIMILA —A-P PROVED 1 JO SL( 03„.1t:4"4.‘rnqinN , I U 1_ Di KI - 05F16 APPIIVANI. RECEIVED nY OF istaMLIA AUG 2 8 1989 EXAM Mr.. PL. P,‘N 4. 4t.42E.Rki, Auei 21, 195, " • -,.°0-.44*Ars-...,#« "- r r - 11111111111111111111111111111111111111111111111111111111111111111111(1-;IrITI31:11-1?17iI71711:11111'1^1111.11'11111-1:1-1-111111111 111.111 illflilliiilliillilli11111111111111 1111/111111111111111111111111111 0 ""NC" 1 2 3 4 5 6 7 8 9 10 11 MAUEIPIGFRMANY 12 1 NOT: If the micrefilthed document is less clear than this i _..Fkai EP LexATi0N of I'Z'x4a' TEM'P0?Aele O FI .E TrzAILE - (To bs R 1cvEb Rzioia To -f . 4 .e-ro,L - 544510eQ. `C i,) C 7ti +ST \.3 OS r3 57! tIV:FN c. 40 43 °' 1 i 1 1 OFF^ e. 0 s% LANDSCAPE r--- —, Vi q o. Ic ts 1. ipk:zeHC�v�.s 671:: \ 4 St- IOt..0 kocr-‘ GI= PAw4,1■0 13 76 5 (: 100o 14i- �014-3 I : HOO 1© TOTAL R z4o 2•41 30% Cori? A cT !,1 AN n1 C ' 1 V\T... Ux_:114 1 Co J LCG k' p b, MAT6T"1 '1 ,r�14..A 1 . 1[A isIVA dAccu AI` Lk Ap g TLT NsTAL.L LI 6' X t co' CITY OF TUKWILA APPROVED SE • N . 1 9 'dul 1. ARP \ � e � ---New 5,cTeu©ep �UR� 1.4 \z. BU ID IVIS!0�1 RECD CRIf OF WAWA AUG 2 8 1989 ats JAPA1.iE ,5., MAPLE TO MA 1°f 4 SKI 6Tf 1 vy AND Caved. 'r,Q's�L.; ��..: �.`++ t''u.:!„r..'x�:.......x•�Ic.,,, c�.'ri�';, �s:::c., ' P 0 16 THS INC" 1 I1I 1,1 f1I I ICI II 1I lI i1 11 11 ►I ,I II ,I I1 1I II 1I lI 1I II lI lI iI lI 1I i1 lI, l 11 11 1I lI 1I ll ii l I1I I I1I l ICI I1I l 11 111 l 111 I11 l I1I l I1I lIII ( 111 l I1I i 1!1 II ,I {i ,I II 1I II 1I II 1I II 1i Ii 11 II iII iI II ,I 1 1 •:. 2 /f 5 6 7 8 9 10 11 MAUF IIJ GERMANY 12 NOT If the micrcfilmed document is less clear than this 5 vq MAC