Permit 0254 - McCann Construction Company - Offices and Doors
BUILDING PERMIT CIT( OF TUKWILA BUILDING fk...MIT 14475 - 59th Ave. So. / Tukwila, Washington 98067 Applicant to complete numbered spaces only. BUILDING PERMIT NO. N2 254 JOB ADDR ESS 1000 Andover Park East �!- '4 r' a,,t l (1) ; f .. .�_� o. - C- 4_•i. -., DATE 6/27/73 LEGAL 1 DESCR. LOT NO. BLK 1 TRACT ( SEE ATTACHED SHEET) OWNER MAIL ADDRESS ZIP PHONE 2 McCann Construction 6013 Perimeter Rd. So. Seattle Ro. 2 -2555 CONTRACTOR MAIL ADDRESS PHONE LICENSE NO, 3 McCann Construction $013 Perimeter Rd. So. Seattle ARCHITECT OR DESIGNER MAIL ADDRESS PHONE LICENSE NO. H. P. Blean 397 ENGUNEF.R MAIL ADDRESS PHONE LICENSE NO. 5 LENDER MAIL ADDRESS BRANCH 6 IISE OF BUILDING Warehouse a - / Vs: _ / :1J95 -- S Class of work: • NEW ❑ ADDITION !;S ALTERATION ❑ REPAIR ❑ MOVE ❑ REMOVE 9 Describe work: Add offices and doors 10 Change of use from Change of use to 11 Valuation of work: $ 14,000.00 PLAN CHECK FEE 26.00 PERMIT FEE 6.00 SPECIAL CONDITIONS: Type of Const. III —N Occupancy Group F Division 2 •ccupan oa. is imi e• o en 10 emp oyees — mus • e poste. at all doors and 5lze of Bldg. No (Total) Sq. Ft.change No. of Stories One Max. Occ. Load 10 strictly observed — No retail sales or whsle clearance to general public allowed. Fire Zone III Use Zone C M Fire Sprinklers Required laYes MND APPLICATION ACCEPTED BY " C ` PLANS CHECKED BY. AP.ROVED FOR ISSUA CE 5 ` r� a /LVu �� • No. of Dwelling Units OFFSTREET PARKING Covered SPACES: Uncovered -.,�+ _ Special Approvals Required Not Required — n Approved NOT f SEPARATE PERMITS ARE REQUIRED FOR ELECTRICAL, PLUMB- ING, HEATING, VENTILATING OR AIR CONDITIONING. THIS PERMIT BECOMES NULL AND VOID IF WORK OR CONSTRUC. TION AUTHORIZED IS NOT COMMENCED WITHIN 60 DAYS, OR IF CONSTRUCTION OR WORK IS SUSPENDED OR ABANDONED FOR A PERIOD OF 120 DAYS AT ANY TIME AFTER WORK I$ COM- MENCED. 1 HEREBY CERTIFY THAT 1 HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE AND CORRECT. ALL PROVISIONS OF LAWS AND ORDINANCES GOVERNING THIS TYPE OF WORK WILL BE COMPLIED WITH WHETHER SPECIFIED HEREIN OR NOT, THE GRANTING OF A PERMIT DOES NOT PRESUME TO GIVE AUTHORITY TO VIOLATE OR CANCEL THE PROVISIONS OF ANY OTHER STATE OR LOCAL LAW REGULATING CONSTRUCTION OR THE PERFORMANCE OF CONSTRUCTION. ZONING HEALTH DEPT. FIRE DEPT. SOIL REPORT OTHER (Specify) FOUNDATION FRAMING SIGNATURE OF OWNER (IF OWNER BUILDER/ —2 7" 7 3 FINAL C Ej �-� ____ SIGMA E OR AUTHORIZED G NT (DATE) WHEN PROPERLY VALIDATED (IN THIS SPACE) THIS IS YOUR PERMIT PLAN CHECK VALIDATION M.O. CASH PERMIT VALIDATION OCCUPANCY PERMIT REQUIRED M.O. CASH CITY OF TUKWILA BUILDING PERMIT ''' IILDEIG PLUM' 14475 • 59th Ave. So. / Tukwila, Washington 98067 Applicant to complete numbered spaces on /y. JOB ADOR EBS /000 4,0, •ceItovc ✓ G at ..1 I : DATE - I3 — 73 LEGAL 1 oIsCR. LOT P10• .... SLR TRACT ( SEE ATTACHED SHEET OWNER /' MAIL ADDRESS ,/ ZIP PHONE 2 C C eV aS M Cm 1 1' �"• r 0/ 3 Pr✓ i Er f6 ✓ 1901..Sv L- Z-! •,... _lip CONTRACTOR MAIL ADDRESS PHONE LICENSE NO. 3 tI II PI ARCHITECT OR DESIGNER MAIL ADDRESS PHONE LICENSE 110. a /t !1 EN01 EE MAIL ADDRESS PHONE LICENSE NO. 5 // rr • ,/ LEPIOER MAIL ADDRESS BRANCH 6 USE OT BUILDING WaLegrAd 8 Class of work: 0 NEW • ADDITION ALTERATION • REPAIR • MOVE • REMOVE ) Describe work: /' �el� Aeic lest IQVV.r 10 Change of use from ...- Change of use to _ . 0 11 Valuation of work: $ / 0 0 PLAN CHECK Typo of ' 4 Const. `i`J �. FEE ~ ht L Occupancy Group PERMIT FEE et-, 1- •U �co ,..� Division �... SPECIAL CONDITIONS: Or..''•'.11 r' /1 i �1' i NN," I : ) IYIti i;r,` .• Ir\ —�'rr) c) ; L IVVi. ),,.}r.v .e'.._..• �,A,i�l Y:Y" •',•'it ((r «- lir JLLJ.___ Size of Bldg. IAA (Total) Sq. 'Ft. CIRP,,1'�i'., No. of ()tit.- Stories Max. I Occ, Load 10 ktvt,l.'.r; /coy , =!,!'rC'. y.) (1�;',� }r'„'ll' 1,„ ' 1 L iL.. t. ; ,/• i;' 'III: ;, "• � � ",..•r't riu' 1 ,) "19 (1, 'r.1I rI'V�'C)c. )\ i. LdV!(f, :. Fire Zone .._�-1 -��"• Use Zone - Fire Sprinklors RogUlrod ❑NO APPLICATION ACCEPTED BY: ' '.) PLANS CHECKED BV: `- ° °-' APPROVED FOR ISSUANCE BY: No, of Dwelling Units OFFSTREET PARKING Covered SPACES: Uncovered NOTICE SEPARATE PERMITS ARE REQUIRED FOR ELECTRICAL, PLUMB. ING, HEATING, VENTILATING OR AIR CONDITIONING. THIS PERMIT BECOMES NULL AND VOID IF WORK OR CONSTRUC- TION AUTHORIZED IS NOT COMMENCED WITHIN 60 DAYS, OR IF CONSTRUCTION OR WORK IS SUSPENDED OR ABANDONED FOR A • PERIOD OF 120 DAYS AT ANY TIME AFTER WORK le COM- MENCED. 1 HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE AND CORRECT. ALL PROVISIONS OF LAWS AND ORDINANCES GOVERNING THIS TYPE OF WORK WILL BE COMPLIED WITH WHETHER SPECIFIED HEREIN OR NOT, THE GRANTING OF A PERMIT DOES NOT PRESUME TO GIVE AUTHORITY TO VIOLATE OR CANCEL THE PROVISIONS OF ANY OTHER STATE OR LOCAL LAW REGULATING CONSTRUCTION OR THE PERFORMANCE OF CONSTRUCTION. - aA $ Special Approvals Required Not Required Approved ZONING HEALTH DEPT. FIRE DEPT. SOIL REPORT OTHER (Specify) FOUNDATION FRAMING S UNA •• I / . '- FINAL ICH TURC 0 AUTHORIZE • AGENT IOATC) WHELP OPERLY VALIDATED (IN THIS SPACE) THIS IS YOUR PERMI PLAN CHECK VALIDATION M. CASH PERMIT VALIDATION 1.3I . n CASH Frank Todd, Mayor CITY of TUKWILA 14475 - 59TH AVENUE SOUTH TUKWILA, WASHINGTON 98067 June 18, 1973 McCann Construction Co., Inc;. 8013 Perimeter Road So. Boeing Field Seattle, Washington 98108 Attention: Mr. Hal Blean,. Subject: Remodel at 1000 Andover Park East Gentlemen: Please find enclosed one copy of the Tukwila Fire Department plan review of your proposed project. In addition to the Fire Department comments, I have the following to add: 1. The additional truck door on the West appears to lack proper reinforcement per the UBC requirements for "around openings ". Sec. 2622(d). Please justify this new opening with structural calculations and show compliance with the UBC. The new rail door which is designated to go through a knock- out panel appears to be mis- located. The permit drawing for Project 161 does not show a knock -out panel at the location . you claim. Therefore, you must justify this new location as for item #1 above. Final . approval of your permit application is being withheld pending resolution. of the above and enclosed comments. .Very truly yours, John Offic FIRE DEPARTMENT CITY of TUKWILA John Richards Building Department City of Tukwila Dear John: Frank Todd, Mayor 5900 SO. 147TH ST. TUKWILA, WASHINGTON 98067 Fire Prevention Bureau June 15, 1973 Re: Tenant Improvements at 1000 Andover Pk. East In reviewing the above mentioned project plans, the following are requirements of the Tukwila Fire Department: 1. The square foot area of the facility is: Office = 1120 sq. ft., Warehouse = $77.5 sq. ft.; By Table 33-A of the UBC, the area will legally accommodate' 40 persons. This requires two exits per Sec. 3302 of the UBC. 2. All plans for sprinkler, hydrant & standpipe systems shall first be approved by the Washington Survey and Rating Bureau, then by the Tukwila Fire Dept. 3. Per UFC Sec. 10.104 (b), "All doors in or lead - ing to exits shall be maintained openable from . the inside without the use of a key or any special knowledge or effort at all times when the building or area served thereby is occupied". All doors, including exits shall be identified per OSHA, Section 1910.37 (q). Fire extinguishers shall be provided per NFPA #10, as a minimum requirement. When in the opinion of the Fire Prevention Bureau, building contents or operations therein are of a hazardous nature, additional extinguishers (in excess of NFPA requirements) may be required. Extinguishers shall be located so as to be in plain. view (if at all possible). If not in plain view, they shall be identified with a sign stating - "FIRE EXTINGUISHER" with an arrow pointing. Please include these comments in your review of the above mentioned project. E w � JH:vma JUN c 1973 cc: T.F.D. fi e Fire Prevention Officer ncerely, James Hoel McCANN CONSTRUCTION COMPANY, INC. 8013 PERIMETER ROAD SOUTH • BOEING FIELD SEATTLE, WASHINGTON 98108 June 21, 1973 Building Department City of Tukwila 14475 - 59th South Tukwila, Washington 98067 Attention: Mr. John Richards Re: Dear Sir: Tenant Improvements for Golden West Sales 1004 Andover Park.Bast Tukwila, Washington We have reviewed with the tenant the maximum anticipated number of people that will be employed at the above facility. Golden West Sales will have five permanent employees and one supervisor for occasional visits. At no time will the employees at the facility reach 10. Since the distance of travel to the exit is less than 200 feet and the number of employees is less than 10, it is requested that the front entrance, supported by . rail and truck doors, be considered as within the intent of the Building Code. HB:jf Sincerely, Hal Blean Manager of E i e /Design JUN 2G 1973 CITY OF TUKWILA GENERAL CONTRACTORS 2061762 -2555 206/762-8124 5X 1ST /NG WALL AND OPErl /N6S y Eth (10 PO PE'' 35'1 Waco 57U4o W4LL PER 451 1 (Awcur) PA Q-1-1/4 L. LEVA1710. - =OLSEN & R,ATTI Consulfing Englnnnn . 1411 Fourth Avenue ,Seattle,, Wash. 98101 MAin 4.7045 PROJECT .r1e.01 —I E-GT Ca. I CLIENT M4C4NN DESIGN d C. B NEW OPNG - Ll t4 N0II DATE KG •%.Z. `7 3 JOTS NO -7316 - 0) SHUT J1' 1 =1 —o NEW !D cc iD 34 p .` ��2=U' .. 9'L.Q =d ` em 1 o MOT V1W OP.N4.. OLSEN & RATTI PROJECT— ; ...,10--r tt I CLIENTI.A4u1`' 1 4 . Consulting Engineers DESIGNS .1411 Fourth Avenue Seattle, Wash. 98101 A, r Uhl �\ pt CHECK MAin 4 -7045. NEW, OP/■14 LiN t A •DATE Gn •z Z 7 j JOe NO /6 "4A SHEET i.../ of ! MEAN cen oJ6 e LINE r,D • WALL Ao V E o% A.) /9 c f rA- 4r Noll JT4 -C.. Fort JN /M p 1_.O4O S F - PIL..'Sr 4T Li'i 8 - tAlo &O STUD ,-& To Zoo Tl O f LINE 8 : 4-A4 2oPsP (.10)1.' •ZS" 't As = , 264,4- 4- (2.7)(1 - ;3) ~ • 05-/ ^11` < *4-e-127 OPAL G- e "a" is Ne-co oP e J'AJ e, L 1AJ '4 WALL RI U it 4- 61 S I�o2i� L 27' -1 3¢-" is 7 a 4404 ' o. Dot OP OPEAJIA) , Io.I S'mr. w, 'Z i - ( 6. s 4 1. 4) r 2-0 U ,4oe Po S-r A4 v.. it (2411/e, s 17 :( /«) /09 Oki eX /0 4vse N'o- (rn. 3SI) cak.: -OLSEN .1 RATTI Consulting Engineers 1411 Fourth Avenue Seattle,' Wash: 98101 MAin 4-7045 • PROJECT E G( I +� CLIENT M t ESIO �� 6;41;0/ ��//AJ E //� CHECK N �uJ cT. 0,1 ■1G S DATI 6 t617 JOBNO 73 U. SHEET of � . GOLDEN WEST SALES, INC. October 3, 1973. Mr. John E. Richards Office Manager Public Works Department _City_,..of . _Tukwi l a 6230 Southcenter Blvd. Tukwila, Washington 98067 Dear Mr. Richards: In response to your letter of September 27, 1973 you are hereby advised that we have removed the carpeting and drapery improvements which created a sales- showroom area within our warehouse at 1004 Andover Park East. You are further advised that we will not use the warehouse portion of our building for purposes of a sales- showroom. Very truly you Laurence D. Purcell Vice. President, Operations /7a cc: J.P. Costello Dave R. Tilton ECEIVE OCT 0919I3 CITY OF TUKWILA 1004 ANDOVER PARK EAST TUKWILA, WASHINGTON 98188 • (206) 675 -0440 • N" . •J , 62210 Southoontor Zen..zi©wmrra1 .�. ., : �.�..'.�... ,.... Tukwila, 1Afashington SE1067 telephone C 2l0Mi3 242 - E177 September 27, 1973 Ei Golden West Sales 1004 Andover Park East Tukwila, Washington 98188 al Attention: Mr. Dave'Tilton, Manager E Gentlemen: Q After completing an occupancy inspection of your business in July, a T wrote a letter to McCann Construction Co., Inc. discussing the code violations involved. McCann Construction has informed me that they did not actually do the work nor do they own the building. ILI Therefore, McCann's position is one of no involvement. iA Since that time, I have learned that the Seattle First National Bank al Trust Department is currently handling the lease program for the new • owners, the Schoenfield Trust. Mr. Don Spencer of Seattle First has been informed of the code violations. Mr. Spencer has taken the position that the owners of the building (being represented by him) are not responsible for the code violations. Therefore, Gentlemen, you as tenant apparently ordered the work done as well as desired it done. Both the contractor and the owner say your firm is to be held responsible. U You are hereby instructed to remove the carpet and curtain improve - ments which create a sales -show room area within the warehouse. You are further instructed that use of the warehouse portion of your 1• building for the purposes of a sales -show room is in violation of (l Ordinance #742, amending the Uniform Building Code of the City of Tukwila. a Failure to comply with this order will cause legal action. ial. Very truly yours, ELI (j Joh E. Richards ice Engineer cc: McCann Const. Seattle First Trust Dept. City Attorney Encl: Letter to McCann, July 31, 1973 Ez �3 Floe Frank Todd, Mayor PTV ®c- u U KIWI] LA 14475 • 59TH AVENUE SOUTH. .TUKWILA, WASHINGTON 98067.. • 31 July 1973 McCann Cons.tructiori 'Company ' ATTN: Mr. Hal Blean ,'.8013.Permimeter Road South Seattle, Washington 98108. Gentlemen: At your company's request, a. final inspection on the remodel at 1004 Andover Park East has been accomplished. The inspection has revealed that the extent of the remodel has.exceeded•that which was'approved by the •issuance of Building Permit #254. The extended work has served to create a 'sales and /or merchandise display area within the warehouse space. Such areas are required to be separated from one another by a one -hour fire 'resistive enclosure. The existing situation is that the wall separation is by a drapery and there is no ceiling ,in the area. The proper'fire- resistive separations shall be provided • w4.thin 10 da;'.s or proper, legal action shall be taken. Very 'truly yours, . John /E. Richards` 0ffi a Engineer 1 4� Fire Prevention Bureau July 31, 1973 Golden West Sales 100� Anciq;",,,,rbk,�.Eas�t "^-^ -- ~°�"""°`�'Tv" w`'i1a, Washington 98188 Gentlemen: In regard to as occupancy inspection of this date and in reference to my letter of June 15, 1973, please note the Following items which require attention before your area may be legally occupied: 1. A second approved exit is required. (Refer to letter of June 15.) 2. No drawings of sprinkler system modification have been received by this office. 3. All doors, including exits shah. be identity fled per OSHA, Section 1916,37(q)• 4. Four 24- gallon pressurized water fire exting- uishers are required. Two dry chemical exting- uishers rated at least 10 B-'O are required. Per OSHA requirements, extinguishers with a gross weight of 40 pounds or less shall be hung so that the top of the extinguisher is not higher than 60 inches above the floor. Extinguishers weighing more than 400 pounds, shall be hung so that the top of the unit is not higher than 42 inches above the floor. Extinguishers shah, be located so as to be in plain view (if at all possible) . If not in plain view, they shall be identified with a sign stat- ing "FIRE EXTINGUISHER" with an arrow pointing. If the color of extinguishers is other than red, they shall be provided with a background or mounting board, red in color, not lees than 2 square feet in size. j 5. A City of Tukwila Business License is required. • • golden West Saes July Up 1973 page► Fire Prevention ° Bureau'. Any olrerlooked hazardous •cOndit.on and/or violation Of the Fire prevention Codes of the City- of Tukwila dons not imply approval of such condition or violation Tour cooperation in complying with the requirements. of the Cite Firms Code will be appreciated. J �3v fa SincorelY, JiltmeS Boca C0 i a . Bleano McCann Fire Prevention Or `icOx' COnetx!uctibf Coo 11ohn Richards.: Bldg* Dpt. 'T.F.D4t file AU: 1.; 1973 TUKW Frank Todd, Mayor • CITY of TUKWILA 14475 - 59TH AVENUE SOUTH TUKWILA, WASHINGTON 98067 31 July 1973 McCann Construction Company ATTN: Mr. Hal Blean ". 8013 Permimeter Road South Seattle, Washington 98108 Gentlemen: At your company's request, a final inspection on the remodel at 1004 Andover Park East has been accomplished. The inspection has revealed that the extent of the remodel has exceeded that which was approved by the issuance of Building Permit #254. The extended work has served to create a sales and /or merchandise display area within the warehouse space. Such areas are required to be separated from one another by a one -hour fire resistive enclosure. The existing situation is that the wall separation is by a drapery and there is no ceiling in the area. The proper'fire- resistive separations shall be provided within 10 days or proper legal action shall be taken. Very truly yours,