Loading...
HomeMy WebLinkAboutPermit 578 - 3M CompanyII.DING PERMIT CITY )F TUKWILA BUILDING PE`, MT TUKWILA, WASHINGTON klA. BUILDING PERMIT No. N? 578 i OWN4� _ -� h7 .. i (5 /11 ADD�iE88 ? Aq e. :1-: .'` S "T; L 'I(ODRE88 ' PHONE / GAP////41 BUILDER : 1+ /yam,, AR I L7 lJ 0 1 i' Y t ' • / G. ,,./r /� �+ for on ; Id 5 e_a_ le__ SQ. FT, . tit) EXISTING BUILDING AREA /!! I / l) L ' ` 2 1,;_xj 6'7', 4. r i-'. - BO, FT. JOB ADDRESS STREET 7 t� I �+�.. NUM. it N0 11 V i7 , / / e //� USE ZONE C�� _ -1 LEGAL if y .7 /yj, /1)∎ f [1 .01. i c 1V['l. 1.4:• �-� J�/ , LOT SIZE LOTAREA JJ •J • i) , 2, r /,vv 1 �/,� r /,}�1J ' - .-( ! ( E 1: i ,�o1._ • / / . % /If, 6'' /j'./0 LOT BLOCK YARDS DISTANCE TO PROPERTY LINES MAIN BUILDING SET BACK SIDE YARD REAR YARD NEAREST BUILDING ACCESSORY BUILDING SET BACK I SIOE YARD REAR YARD NEAREST BUILDING CLASS OF WORK SIZE OF BUILDING Jn4 it j ,� MAIN BUILDING WIDTH DEPTH ! AREA / 23 () FT. X •rte / FT, ,y (J �4 ,� f'SQT FT. W TYPE OF CONSTRUCTION ACCESSORY BUILDING WIDTH DEPTH AREA X FT. ' ` FT. = SO. FT. (V SQ. FT, . tit) EXISTING BUILDING AREA /!! I / l) L ' ` 2 1,;_xj 6'7', 4. r i-'. - BO, FT. LOT COVERAGE TOTAL AREA OCCUPIED LOT AREA LOT AREA OCCUPIED .....- 7 i> ti ,.•I 7 SO. FT. SQ. FT, /0 EXTERIOR FINISH OCCUPANCY /) L..y. TO BE USED \ t / AS V` / a r �/\ 0 bt S i. VVV HOW HEATED BASEMENT SIZE BQ, FT. ROOMS TOTAL BED pOOMB I BATHS LIVING L.D COMBO DEN KITCHEN NOOK K D HOOK ATT. r3 GARAGE DET. ❑ VALUATION OF ALL IMPROVEMENTS HOUSES ; GARAGES HOUSE • ATT, GARAGE $ (I OTHER S / ! I / �Q Q (l%` FOUNDATION OK FRAMING OK FINAL INSPECTION REMARKS; DESCRIPTION OF ANY WORK NOT COVERED ABOVE WARNING Notify Building Department by Street Address and Permit Number when ready for inspection. Work must not be covered before inspection and OK for covering has been given by Inspector in writing on Permit Placard. I hereby acknowledge that I have read this application and state that the above is correct and I further agree to comply with all City Ordinances, State Laws, and lawful orders of the Building Inspector governing building con- struction. Written Authorization of the owner must be pre- sented when work is done by occupant or lessor. OWNER -27Z o0`= PERMIT FEES: (THIS SPACE FOR BUILDING DEPARTMENT USE ONLY) n c e...1). I4 -v.-- HOUSE & HOUSES / l GARAGE S GARAGE $ BOND NO TOTAL FEES 1 / 7 j ! /''.. �BYCEIVED DT OTHER BUILDING NOTICE: THIS PERMIT DOES NOT COVER PLUMBING, SEWER, OR WIRING INSTALLATION. / 6 FEES S // /4� DATE �/ PERMIT PLACARD MUST BE POSTED ON THE WORK CITY OF TUKWILA APPLICATION FOR BUILDING PERMIT Mi► Na 4 m DSO srA Address /AI". �� /d / Phone Owner 3-4/ C�/l'%.t4L' y, Builder Address Phone Architect &t,L'A) Ct•40IGivr /icr rkeiQ S Address oZ /zi` OeleLs A‘ Phone Al 3 8‘.9, Value of Construction $ / 96/, 6UCo 4S770/i1 The following information to be attached to this permit 1. Two (2) copies of legal description of property V 2. Plot plan 3. Two (2) copies of building prints Additional information or comments mod. .62- ' ) „67,1,4a, Signature of Applicant ,G°o.P7A0 A L 4G —S'e4.771E Mailing Address of Applicant ate of Application (` #578 (1914 OVERLAKE 6UILDING CONSULTANTS 18071 N.E. 2NO STREET August 18, 1969 • BELLEVUE, WASHINGTON 98004 • SH. 6.6223 mr. Frank Zepp Building Official City Hall Tukwila, Washington Dear Franks Plan Check No. 0 -343 Uses Warehouse Addition Type III -N Group F -2 Fire Zone No. S' Sehmic Zone No. 3 1967 Uniform Building Code 3m Company /DO cd avW 041 vi We are returning to you under separate cover the above subject plan which has been checked for conformance with the Uniform Building Code. This plan checks out very well except for the following minor provisions) 1. No point of the warehouse should be more than 200 feet from an exterior exit, horizontal exit, enclosed stairway, or exit passageway. Section 3302 (d). 2. Special inspection in conformance with Section 305 is re- quired fors a. Structural concrete based on an ultimate compressive strength in excess of 2000 pounds per square inch. b. All structural and light gauge welding. o. Installation of high strength bolts. d. Prestressing work. If we can be of further service please do contact us. Please find enclosed our invoice No. 3815 check. Very truly yours, OVERLAKE BUILDING CONSULTANTS R. S. "Dick" Mangan RSM/ j enc os -urea not hesitate to covering this plan • SOLD TO. '• i OVERLAKE BUILDING CONSULTI' "5' 16071 N. E. 2nd ST. BELLEVUE, WASH. 913004 AREA CODE 206 SH 6=5223 Building Department City Hall Tukwila,'` aahington. INNOiCE. NO. 3815 DATE 8/18/69 YOUR ORDER NO. SHIPPED TO. OUR ORDER NO. SALESMAN TERMS` net. ''QUANTITY , ORDERED: QUANTITY SHIPPED STOCK NUMBER /DESCRIPTION DATE SNIPPED SHIPPED 'VIA UNIT PRICE UNIT Plan . check No. 0..343 Warehouse Addn/ 3_rn Company Plan chill* Pee . ., • ,' ', 0 0 • •: • • Wll. ON ,IONCG COMPANY•,© 100$ 0 PRINTGD IH $67 BINDON WRIGHT & PARTNERS ARCHITECTS August 22, 1969 Building Department City of Tukwila 11475 - 59th South Tukwila, Washington 98188 Attention: Mr. Frank Zepp Re: 3M Company Warehouse Addition Tukwila, Washington Gentlemen: This will acknowledge receipt of your memo of August 20th transmitting the results of the plan check by Overlake Building Consultants. With respect to their Items 2, a, b and c please refer to the specifi- cations, page le -11, stating that the Owner will provide services of a testing laboratory for these items. There is no prestressing work (referred to in their Item 2d) in this project. As a result of their Item 1 comment we have restudied the possibile paths of egress from the warehouse, illustrated by the enclosed sketch. You will note that by moving the two doors on the south wall toward the center all of the warehouse floor area will be within the allowable 200 feet of travel, except for the shaded triangular portion in the northeast area. You will also note that in that area there are several trucking doors which normally stand open when the warehouse is occupied and probably would be used for emergency exit even though they don't strictly conform to Code requirements for exit doors. LEONARD W. BINDON, A.I.A. • JOHN L. WRIGHT, F.A.I.A. • ELTON C. GILDOW, A.I.A. • GEORGE A. HARTMAN, A.I.A, • CLARK TEEGARDEN MARGERIE GARDNER, EXEC. SECRETARY NORTON BUILDING, SEATTLE, WASHINGTON 98104 • 206.623.3646 SilYI .�.;..CM.w�:.,r�':zA.r..t•..,y, .:ldi'- 4i�`9 +1',fs Building Department .City:of Tukwila August 22, 1969 Page Two If you agree that this would be a satisfactory solution we will request: permission f.rom.the Owner'to,move the south doors as-indicated. We wi.li appreciate your consideration of this matter. Yours very truly Clark Teegarden BINDON ARCHITECTS WRIGHT & PARTNERS Pittsburgh Testing Laboratory 826 Northwest .49th Street Seattle, Washington 98107 Gentlemen: September 5, 1969 Re: 3 -M Company Warehouse Addition Tukwila, Washington This is your official notification that your firm has been selected to carry out the inspection in accordance with Section 1 -e of the specifi- cations. The Contractor will arrange for all site inspection. Bindon /Wright & Partners' approval is required for any overtime work. All invoices shall be in accordance with your proposal dated August 20th, and shall be addressed to 3 -M Company, Building 42 -2W, Box 3331, St.. Paul Minnesota in care of Bindon /Wright & Partners'. Copies of all reports, except roofing, shall be sent to Building Department, City of Tukwila, 11475 . -59th South, Tukwila, Washington 98188. Enclosed is a, copy of plans and. specifications, general set #12. • Yours very truly, RES: rp Enclosures . cc: 3 -M Company;(w /encl) City of Tukwila Building Department, (w /encl Eberharter &.Gaunt, Inc.. (w /encl) R. E. Schnell LEONARD, W, BINDON, A,1 A, • JOHN L, WRIGHT, F,A.1A, . ELTON C. GILDOW, A.I,A . GEORGE A, HARTMAN, ALA, CLARK TEEGARDEN MARGERIE GARDNER, EXEC, SECRETARY .. NORTON BUILDING, SEATTLE, WASHINGTON 98104 206. 623•36413 t. 4 !!w3 ' �� Gr' ,�'•,G Piro J�. t rimaael. �.,i Ei Bum ILLS 3ioa diremar ESTABLISHED 1881 lassPECTiNG ENGINEERS AND CHEMISTS 020 NORTH WEST 40TH STREET SEATTLE, WASHINGTON 08107 August 20, 1969 AS A MUTUAL PROTECTION TO CLIENTS. THE PUBLIC AND OURSELVES. ALL REPORTS ARE SUBMITTED AS THE CONFIDENTIAL PROPERTY OF CLIENTS. AND AUTHORIZATION FOR PUBLICATION OF STATEMENTS, CON• CLUSIONS OR EXTRACTS FROM OR REGARDING OUR REPORTS IS RESERVED PENDING OUR WRITTEN APPROVAL, /0 �/"/„.a0 et/ , fi<%/2 /Gwwj 7114. R42J /s/ /ZS', — 46' 3 -M Company bt4= /AP.R'.oe. cPF ..yG eitc-r ci/= a ` /// '�"e Building 42 -2W T, -/i..7 ��d4 .,, '7,e6'Y /=o... C'o.c/G/z4r.r: T�j�! �96� Box 3331 ` '=S''%,.i t� i.5/E�� C .P i� /A:'4�,t 7-A--.5.13- /� % St. Paul, Minnesota /� ,�•=lt%,vI/:�� �-s:., /V AL ' 5've' A2/74' /4 i3 /s, v// de/V irr-1•Civ2 .rY �C+c:/r';5._= 'Gsi;�r..S i.,� /i +�.C' l�:.ST..5, 4'i Attention: Harold Hanson RE: Structural Inspection & Tests �'�l� 3 -M Warehouse ✓/ Andover Park Seattle, Washington Dear Sir, Confirming our conversation we wish to offer our services for Structural Inspection and Testing on subject project. We feel we are in an ideal position to perform the required services having provided similar services on the original building several years ago. Our charges for subject project would be based on the following schedule of fees: Inspection (all categories) $ 8.00 /hr. Overtime (+ 8 hours /day, Saturday, Sunday & Holidays)$12.00 /hr. Travel $ 8.00 /hr. Mileage $ .10 /mile Concrete cylinders $ 3.75 /each All work of this project would be under the direct supervision of a.Professional Engineer Licensed in the State of Washington. We hope the foregoing will merit your approval and look forward to serving you on this project. KDD /ks • cc Bindon & Wright Milwaukee (PTL) R.C. Emmett Very Truly Yours, PITTSBURGH T^SVSTING LABORATORY RAKE, Manager istrict PITTUUURGH NEW YORK BOSTON PHILADELPHIA CLEVELAND DETROIT ST. LOUIS BUFFALO GREENSBORO. LOUISVILLE MEMPHIS SALT LAKE CITY SAN FRANCISCO NEW ORLEANS SEATTLE PORTLAND BIRMINGHAM BATON ROUGE LAFAYETTE MILWAUKEE INDIANAPOLIS ATI.ANTA HOUSTON DALLAS JACKSONVILLE TAMPA MIAMI `CHICACS, *YRACUB•E TAL...AHAKbY.G I:IJ31".N1t LHJHIIAN NAUIIVILLE ROANOKE CHATTANOOGA DAYTONA GAINSVILLE ROCHESTER SPOKANE MORGAN' CM( ASSOCIATES AT I • LDS 1010E140 TQUQNTQ MONTREAL LONDON. ENGLAND WIN STONLSACCM' t. Bindon /Wright & Partners Norton Building • Seattle, Washington 90104 Attentions Mr. Clark Teegarden Dear Sirs: In reference to your letter of August 22, 1969 regarding the egress routes from the 3MCompany Warehouse Addition. ,:I have reviewed your sketch and agree that the moving of the doors on the `South wall is a satisfactory solution. Very truly yours, .' site plan