Loading...
HomeMy WebLinkAboutPermit D06-241 - Money Tree - OfficesMONEY TREE 6720 FORT DENT WY EXPIRED 03 -25 -07 D06 -241 City of Tukwila Department of Community Development / 6300 Southcenter BL, Suite 100 / Tukwila, WA 98188 / (206) 431 - 3670 Parcel No.: 2954900455 Address: 6720 FORT DENT WY TUKW Suite No: Tenant: Name: MONEY TREE Address: 6720 FORT DENT WY, TUKWILA WA DEVELOPMENT PERMIT Owner: Name: JOHN C RADOVICH LLC Phone: Address: 2000 124TH AVE NE #B 103, BELLEVUE WA Permit Number: D06 -241 Issue Date: 07/12/2006 Permit Expires On: 01/08/2007 Contact Person: Name: MARK PETERSON /JENNIFER MUKAI Phone: 425 641 -9200 Address: 601 108 AV NE, BELLEVUE WA Contractor: Name: BAKER CONSTRUCTION Phone: Address 2711 E SPRAGUE AVE, SPOKANE, WA Contractor License No: BAKERCD066CZ Expiration Date:04 /06/2008 DESCRIPTION OF WORK: DEMOLITION OF EXISTING INTERIOR WALLS AND DOORS - CONSTRUCTION OF NEW WALLS AND DOORS (5 OFFICES) Value of Construction: $75,000.00 Fees Collected: $1,679.22 Type of Fire Protection: SPRINKLERS Uniform Building Code Edition: Type of Construction: VB Occupancy per UBC: 0008 Public Works Activities: Channelization / Striping: N Curb Cut / Access / Sidewalk / CSS: N Fire Loop Hydrant: N Number: 0 Size (Inches): 0 Flood Control Zone: N Hauling: N Start Time: End Time: Land Altering: N Volumes: Cut 0 c.y. Fill 0 c.y. Landscape Irrigation: N Moving Oversize Load: N Start Time: End Time: Sanitary Side Sewer: N Sewer Main Extension: N Private: Public: Storm Drainage: N Street Use: N Profit: N Non - Profit: N Water Main Extension: N Private: Public: Water Meter: N doc: Devperm ** Continued Next Page ** 006 -241 Printed: 07-12-2006 City of Ztkwila Permit Center Authorized Signature' I hereby certify that I have read an ordinances goveming this work will doc: Devperm Department of Community Development / 6300 Southcenter BL, Suite 100 / Tukwila, WA 98188 / (206) 431 -3670 Date: CM �7,11l,p permit and know the same to be true and correct. All provisions of law and ith, whether specified herein or not. The granting of thi ermit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating const rmance of work. I am authorized to sign and obtain this developme t permit. Signature: C � Date: (C ` -0G Print Name: C This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. 006 -241 Printed: 07 -12 -2006 City dr/Tukwila Parcel No.: 2954900455 Address: 6720 FORT DENT WY TUKW Suite No: Tenant: MONEY TREE 1: ** *BUILDING DEPARTMENT CONDITIONS * ** Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: ci.tukwila.wa.us PERMIT CONDITIONS Steven M. Mullet, Mayor Steve Lancaster, Director Permit Number: D06 -241 Status: ISSUED Applied Date: 06/20/2006 Issue Date: 07/12/2006 2: No changes shall be made to the approved plans unless approved by the design professional in responsible charge and the Building Official. 3: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center (206/431- 3670). 4: All permits, inspection records, and approved plans shall be at the job site and available to the inspectors prior to start of any construction. These documents shall be maintained and made available until final inspection approval is granted. 5: New suspended ceiling grid and light fixture installations shall meet the non - building structures seismic design requirements of ASCE 7. 6: Partition walls that are tied to the ceiling and all partitions greater than 6 feet in height shall be laterally braced to the building structure. 7: All construction shall be done in conformance with the approved plans and the requirements of the International Building Code or International Residential Code, International Mechanical Code, Washington State Energy Code. 8: There shall be no occupancy of a building until final inspection has been completed and approved by Tukwila building inspector. No exception. 9: Remove all demolition rubble and loose miscellaneous material from lot or parcel of ground, properly cap the sanitary sewer connections, and properly fill or otherwise protect all basements, cellars, septic tanks, wells, and other excavations. Final inspection approval will be determined by the building inspector based on satisfactory completion of this requirement. 10: All construction noise to be in compliance with Chapter 8.22 of the City of Tukwila Municipal Code. A copy can be obtained at City Hall in the office of the City Clerk. 11: Ventilation is required for all new rooms and spaces of new or existing buildings and shall be in conformance with the International Building Code and the Washington State Ventilation and Indoor Air Quality Code. 12: All electrical work shall be inspected and approved under a separate permit issued by the Washington State Department of Labor and Industries (206/248- 6630). 13: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. doc: Conditions D06 -241 Printed: 07.12 -2006 City thdTukwila 14: ** *FIRE DEPARTMENT CONDITIONS * ** Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: ct.tukwila.wa.us Steven M. Mullet, Mayor Steve Lancaster, Director 15: The attached set of building plans have been reviewed by the Fire Prevention Bureau and are acceptable with the following concerns: 16: The total number of fire extinguishers required for a light hazard occupancy with Class A fire hazards is calculated at one extinguisher for each 3,000 sq. ft. of area. The extinguisher(s) should be of the "all purpose" (2A, 10 B:C) dry chemical type. The travel distance to any extinguisher must be 75' or less. (IFC 906.3) (NFPA 10, 3 -2.1) 17: Portable fire extinguishers, not housed in cabinets, shall be installed on the hangers or brackets supplied. Hangers or brackets shall be securely anchored to the mounting surface in accordance with the manufacturer's installation instructions. Portable fire extinguishers having a gross weight not exceeding 40 pounds (18 kg) shall be installed so that its top is not more than 5 feet (1524 mm) above the floor. Hand -held portable fire extinguishers having a gross weight exceeding 40 pounds (18 kg) shall be installed so that its top is not more than 3.5 feet (1067 mm) above the floor. The clearance between the floor and the bottom of the installed hand -held extinguishers shall not be less than 4 inches (102 mm). (IFC 906.7 and IFC 906.9) 18: Fire extinguishers shall not be obstructed or obscured from view. In rooms or areas in which visual obstruction cannot be completely avoided, means shall be provided to indicate the locations of the extinguishers. (IFC 906.6) 19: Extinguishers shall be located in conspicuous locations where they will be readily accessible and immediately available for use. These locations shall be along normal paths of travel, unless the fire code official determines that the hazard posed indicates the need for placement away from normal paths of travel. (IFC 906.5) 20: ** *MEANS OF EGRESS * *• - IFC Chapter 10 21: No point in a building may exceed the maximum exit access travel distance listed in Chapter 10, section 1015, Table 1015.1 of the International Fire Code and International Building Code. 22: Egress doors shall be readily openable from the egress side without the use of a key or special knowledge or effort. (IFC 1008.1.8.3 subsection 2.2) 23: Exit hardware and marking shall meet the requirements of the International Fire Code. (IFC Chapter 10) 24: Dead bolts are not allowed on auxiliary exit doors unless the dead bolt is automatically retracted when the door handle is engaged from inside the tenant space. (IFC Chapter 10) 25: Exits and exit access doors shall be marked by an approved exit sign readily visible from any direction of egress travel. Access to exits shall be marked by readily visible exit signs in cases where the exit or the path of egress travel is not immediately visible to the occupants. Exit sign placement shall be such that no point in an exit access corridor is more than 100 feet (30,480 mm) or the listed viewing distance for the sign, whichever is less, from the nearest visible exit sign. (IFC 1011.1) 26: Every exit sign and directional exit sign shall have plainly legible letters not less than 6 inches (152 mm) high with the principal strokes of the letters not less than 0.75 inch (19.1 mm) wide. The word "EXIT" shall have letters having a width not less than 2 inches (51 mm) wide except the letter "I ", and the minimum spacing between letters shall not be less than 0.375 inch (9.5 mm). Signs larger than the minimum established in section 1011.5.1 of the International Fire Code shall have letter widths, strokes and spacing in proportion to their height. The word "EXIT" shall be in high contrast with the background and shall be clearly discernible when the exit sign illumination means is or is not energized. If an arrow is provided as part of the exit sign, the construction shall be such that the arrow direction doc: Conditions 1306 -241 Printed: 07 -12 -2006 cannot be readily changed. (IFC 1011.5.1) City &Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: ct.tukwila.wa.us Steven M. Mullet, Mayor Steve Lancaster, Director 27: Means of egress, including the exit discharge, shall be illuminated at all times the building space served by the means of egress is occupied. The means of egress illumination level shall not be less than 1 foot - candle (11 lux) at the floor level. The power supply for the means of egress illumination shall normally be provided by the premise's electrical supply. In event of a power failure an emergency power system shall provide power for a duration of not less than 90 minutes and shall consist of storage batteries, unit equipment or on -site generator. (IFC 1006.1, 1006.2, 1006.3) 28: Manually operated flush bolts or surface bolts are not permitted. (IFC 1008.1.8.4) 29: ** *SPRINKLER SYSTEMS * * *- IFC Chapter 9 -NFPA 13 and 25 30: Maintain sprinkler coverage per N.F.P.A. 13. Addition/relocation of walls, closets or partitions may require relocating and /or adding sprinkler heads. (IFC 901.4) 31: All new sprinkler systems and all modifications to existing sprinkler systems shall have fire department review and approval of drawings prior to installation or modification. New sprinkler systems and all modifications to sprinkler systems involving more than 50 heads shall have the written approval of the W.S.R.B., Factory Mutual, Industrial Risk Insurers Kemper or any other representative designated and/or recognized by the City of Tukwila, prior to submittal to the Tukwila Fire Prevention Bureau. No sprinkler work shall commence without approved drawings. (City Ordinance #2050) 32: All sprinkler system plans, calculations and the contractors Materials and Test Certificates submitted to the Tukwila Fire Prevention Bureau must be stamped with the appropriate level of competency seal. MAC 212 -80) 33: ***FIRE ALARM SYSTEMS*** - City Ordinance #1900 - NFPA 72 34: Maintain fire alarm system audible/visual notification. Addition/relocation of walls or partitions may require relocation and/or addition of audible/visual notification devices. (City Ordinance #2051) 35: All new fire alarm systems or modifications to existing systems shall have the written approval of The Tukwila Fire Prevention Bureau. No work shall commence until a fire department permit has been obtained. (City Ordinance #2051) (IFC 104.2) 36: Call the Tukwila Fire Department at 206/575 -4407 for approval of any system shut down. Have job site address, name and the Tukwila Fire Department Job Number available to confirm shut down approval. (City Ordinance #2051) 37: Contact The Tukwila Fire Prevention Bureau to witness all required inspections and tests. (City Ordinances #2050 and #2051) 38: ***ELECTRICAL*** - IFC - NFPA 70 - NEC 39: All electrical work and equipment shall conform strictly to the standards of the National Electrical Code. (NFPA 70) 40: Accumulation of combustible waste material is prohibited during the demolition phase of this project. Remove and properly dispose of all waste material prior to the close of the working day and as often throughout the day as needed. 41: Any overlooked hazardous condition and /or violation of the adopted Fire or Building Codes does not imply approval of such condition or violation. 42: These plans were reviewed by Inspector 510. If you have any questions, please call Tukwila Fire Prevention Bureau at doc: Conditions 006 -241 Printed: 07 -12 -2006 (206)575 -4407. doc: Conditions City ()r'Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: ci.tukwila.wa.us * *continued on next page** Steven M. Mullet, Mayor Steve Lancaster, Director D06 -241 Printed: 07 -12 -2006 I hereby certify that I have read these conditions and will comply with them as outlined. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provision of any other work or local laws regulating construction or the performance of work. Signature: Print Name: doe: Conditions City oTukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: ct.tukwila.wa.us if1 Date: Steve Lancaster, Director Steven M. Mullet, Mayor 006 -241 Printed: 07 -12 -2006 Site Address: Tenant Name: kOU8f Property Owners Name: 3. C. • lea"p0V lr-4 Mailing Address: CITY OF TUKWILA Community Development Department Public Works Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 httol/www.ci.tukwila.wa.us & Cott VeY( WAY 2F.YxJ I S4 / ?S$L 2[o3 Name: QM- t o tf A /Cir*' F:� Y ea Mailing Address: (0171 to / /Vi ISC f enatatl& E -Mail Address: rY)�(iYIG1/T4lt. Lou GENERAL CONTRACTOR INFORMATION - (Contractor Informadon for Mechanical (pa 4) for Plumbing and Gas Piping (pg 5) ) Company Name: Mailing Address: CeANSTroCeltral 241 t C c2P i&'U AV& Contact Person: CE mo 1 E -Mail Address: J ekby i bA»vlknsl nt l foil-, Contractor Registration Number: r'$At1= 11O O(i(oCZ Q'. Applications■Fams- Applications On Line 3 -2006 - Permit Applicaion doe Revised 0 -2006 bb Project No. Building Pennit No. Mechanical Permit No Plumbing/Gas Permit No Public Works Permit No. war office Appli cations and plans must be complete in order to be accepted for plan review. Applications will not be accepted hrough the mail or by fax. * *Please Pnnt ** E mit LOCATION King Co Assessor's Tax No.: C / a - C74-05 Number: 1 Floor: New Tenant: ❑ Yes rg . No wb- 94,ccS City State Day Telephone: 4K Wt. fz.O Zip La* toot State Zip City � Fax Number: 4/24 -I035 fa) T OW. . WA 9,991)2_ City State Zip Day Telephone:_ • 5 1 f S, 5 kt' Fax Number: �vi• S3 •372-2) Expiration Date: ARCHITECT OF RECORD — All plans must be wet stamped by Architect of Record Company Name: (.(.K— �FQ6iU Mailing Address:�_0.� Contact Person: YYMita- ft fer50", ' E -Mail Address: YYlLiVV pay(3Ff rrkt l-tC6f5. La M Fax Number: 4 A' (p31• V240 Day Telephone: 4K State 62+1 - City ENGINEER OF RECORD — Ail plan et stamped by Engineer of Record Company Name: Mailing Address: City State Zip Contact Person: Day Telephone: E -Mail Address: Fax Number: Page 1 of 6 Valuation of Project (contractor's bid price): $ Existing Building Valuation: $ Scope of Work (please provide detailed information): 1u » ,0 U11.106 a eac-41 AJ10 Wilou t.- 141111LS Q I7sJ5 a ( Vl.(4itJ Jf N wwW2 9nors (c o ue-D) • Will there be new rack storage? ❑ .. Yes Provide All Building Areas In Square Footage Below PLANNING DIVISION: Single - family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) *For an Accessory dwelling, provide the following: Lot Area (sq ft): Floor area of principal dwelling: Floor area for accessory dwelling: *Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard:. Will there be a change in use? ❑ ....Yes Q. ApplicationsWorms- Applications On Line\ -2006 - Permit Application doc Revised, 4-2006 bh FORMATION -.206 -431 -3670 (If yes, a separate permit and plan submittal will be required) Compact: Handicap: If "yes ", explain: FIRE PROTECTION/HAZARDOUS MATERIALS: ❑.. Sprinklers ❑..Automatic Fire Alarm ❑..None ❑ ..Other (specify) Will there be storage or use of flammable, combustible or hazardous materials in the building? ❑ .. Yes No If - yes", attach list of materials and storage locations on a separate 8 -1/2 x 11 paper indicating quantities and Material S afety Data Sheets. SEPTIC SYSTEM: ❑ On - site Septic System — For on -site septic system, provide 2 copies of a current septic design approved by King County Health Department. Page 2 of 6 Plumbine Permit The Building Official may grant one extension of time for an additional period not in writing and justifiable cause demonstrated. Section 103.4.3 Uniform Plu I HEREBY CERTIFY THAT 1 HAVE READ AND EXA PENALTY OF PERJURY BY THE LAWS OF THE STA BUILDING OWNER OR AUTH Signature: Print Name: I Date Application Accepted: at r747 ( `^C Q.tApplicaticns'Fmms-Applications Q1 Linea-2006 Permit Application doe Revised. 4 -2005 bh W Upi2.4— , taSe J Mailing Address: too 1 (Q0* City PERMIT APPLICATION NOTES — Applicable to all permits in this application Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. Building and Mechanical Permit The Building Official may grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). INGTON, AN e (current edr N AND KNOW THE AUTHORIZE ys. The extension shall be requested AME TO BE TRUE UNDER 0 APPLY FOR THIS PERMIT. Date: Ji 2D , 7 a ) 6 ay Telephone: K'4 4zeb State Zip Date Application Expires: t2.4n T1 Stall Initial Page 6 of 6 City of Tukwila 6300 Southcenter BL, Suite 100 / Tukwila, WA 98188 / (206) 431 -3670 Parcel No.: 2954900455 Permit Number: D06 -241 Address: 6720 FORT DENT WY TUKW Status: APPROVED Suite No: Applied Date: 06/20/2006 Applicant: MONEY TREE Issue Date: Receipt No.: R06 -01018 Payment Amount: 1,047.69 Initials: JEM Payment Date: 07/12/2006 02:33 PM User ID: 1165 Balance: 50.00 Payee: BAKER CONSTRUCTION TRANSACTION UST: Type Method Description Amount Payment Check 435148 1,047.69 ACCOUNT ITEM LIST: Description Current Pmts BUILDING - NONRES PLAN CHECK - NONRES STATE BUILDING SURCHARGE RECEIPT Account Code 000/322.100 000/345.830 000/386.904 1,014.98 28.21 4.50 Total: 1,047.69 7324 07/12 9716 TOTAL, 104769 doc: Receipt Printed: 07 -12 -2006 Parcel No.: Address: Suite No: Applicant: Receipt No.: Initials: User ID: Payee: ACCOUNT ITEM LIST: Description doc: Receipt Tukwila City of 6300 Southcenter BL, Suite 1001 Tukwila, WA 98188 / (206) 431 -3670 2954900455 6720 FORT DENT WY TUKW MONEY TREE R06 -00906 3EM 1165 MONEY TREE TRANSACTION LIST: Type Method Payment Check PLAN CHECK - NOMADS Description 102297 000/345.830 RECEIPT Account Code Permit Number: Status: Applied Date: Issue Date: Payment Amount: 631.53 Payment Date: 06/20/2006 04:02 PM Balance: $1,047.69 Amount 631.53 Current Pmts 631.53 Total: 631.53 D06 -241 PENDING 06/20/2006 6545 06/21 9716 TOTAL 631.53 Printed: 06 -20 -2006 Project: m o as: — t ( 2 - € Type of Inspection: E I N A A I ` Address: a) Cal+ i.J \ f !fr Date Called: Special Instructions: Date Want e41 "(- �t 1 - 0 L- / P.m. Re ?uester: Phone ,'-4 S-103 Z.._ tylA pproved per applicable codes. INSPECTION RECORD Retain a copy with permit INSPECT! N NO. CITY O TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 DO(. -v- I COMMENTS: Cv 4-54 — Nrc P ( - 9 .tAAN egevilacto 7) Inspe S r: � CA4 Receipt No.: (Date: Date Z ... 1 I 00 REINSPECT ON FEE RF�QUIRED. Pri r to inspection, fee must be at 6300 Southcenter Blvd., Suite 100. Call to sechedule reinspection. El Corrections required prior to approval. Project: /17o Alf y r-R Type of Inspection: Saysaw4cz) a tit Ad ess: O. 7207 ycv' 4 Date Called: Special Instructions: Date Wanted: e - 2 7 C. a.m' p.m. Requester: Phone No: .s09- 4/ 25 — 3 2 INSPECTION RECORD Retain a copy with permit INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 06)431 -367 Approved per applicable codes. Corrections required prior to approval. COMMENTS: sp9ctor: ! Z 0 $58.00 REINSPEdION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to sechedule reinspection. Receipt No.: (Date: Project: "ICA"F y ;, Type of I s ction: - ,.,i '. `' Address: `6 Date Called: G 724 - Special Instructions: Date Wa ed: q - Z_ fc '.0 P.m. Requester: Phone No: v ®approved per applicable codes. INSPECTION RECORD Retain a copy with permit INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431-36 DI Corrections required prior to approval. COMMENTS: 0 1(49/ . / 1 /L "77 an)-- 4/4 / f $58.00 REINSPECT* FEE REQUIRED. Rec to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to sechedule reinspection. 'Receipt No.: 'Date: Proj ct: �0Nfy �te Type of Inspection: �/?A�l /,c % Address: / 6 7-20 r09 - c,t wU Date Called: , Special Instructions: ,..17/'1r /� 5 Date Warms: L/ OG a Requester: Phone No: .poi 4 /75 - 2 0 3? : :14 INSPECTION RECORD Retain a copy with permit INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -36 ;0 Approved per applicable codes. Corrections required prior to approval. COMMENTS: R D,A TG P A,Aofs (141/ 5 A /or r O/` ra ow .4. 441/44bS Datge�;( 6°4 .00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be aid at 6300 Southcenter Blvd., Suite 100. Call to sechedule reinspection. 'Receipt No.: 'Date: Project: I in nn e rfre -- Type of Insp s rim ol-�; fe.. Frei Address: 67 F f - 0e.�( 4 WI Suite #: — /ZS Coract Person: Special Instructions: Phone No.: Needs Shift Inspection: Vi Sprinklers: ki Fire Alarm: e e Hood & Duct: £j,Q Monitor: Pre -Fire: Nv Permits: Occupancy Type: ,S 2_ INSPECTION NUMBER Approved per applicable codes. Word /Inspection Record Form.Doc INSPECTION RECORD Retain a copy with permit CITY OF TUKWILA FIRE DEPARTMENT 006-z-91 c 6 -5 PERMIT NUMBERS 444 Andover Park East, Tukwila, Wa. 98188 206- 575 -4407 n Corrections required prior to approval. COMMENTS: S Cc s, KP / t / -r2K Inspe or: (34Ca) Date: 9/ Hrs.: V $80.00 REINSPECTION FEE REQUIRED. You will receive an invoice from th i .f Tukwila Finance Department. Call to schedule a reinspection. 1/13/06 T.F.D. Form F.P. 113 Project: Honky m t ■ ,, Type of Inspection: svaffil4 co/r4. Address: blip rofe - DL of Wv Suite #: 1,25 Contact Person: .$ -fn'E ( Ait t CoNcsr. Special Instructions: Phone No.: t toe) t \ — 5240 Needs Shift Inspection: Sprinklers: Fire Alarm: Hood & Duct: Monitor: Pre -Fire: Permits: Occupancy Type: INSPECTION NUMBER Word /Inspection Record Form.Doc INSPECTION RECORD Retain a copy with permit CITY OF TUKWILA FIRE DEPARTMENT 444 Andover Park East, Tukwila. Wa. 98188 206 - 575 -4407 IX Approved per applicable codes. 12/2/05 - D o e) - 2'-I I Ow -S- 1 PERMIT NUMBERS n Corrections required prior to approval. COMMENTS: Inspector: Date: c bi s s (U(o Hrs.: n $80.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 444 Andover Park East. Call to schedule reinspection. Receipt No.: Date: T.F.D. Form F.P. 85 02 -02 -2007 MARK PETERSON /JENNIFER MUKAI 601 108 AV NE BELLEVUE WA 98004 RE: Permit No. D06 -241 6720 FORT DENT WY TUKW Dear Permit Holder: Thank you for your cooperation in this matter. Sincerely, se: Permit File No.1)06 -241 City of Tukwila Steven M. Mullet, Mayor Department of Community Development Steve Lancaster, Director In reviewing our current records the above noted pemrit has not received a final inspection by the City of Tukwila Building Division. Per the International Building Code and/or the International Mechanical Code, every permit issued by the Building Division under the provisions of this code shall expire by limitation and become null and void if the building or work authorized by such permit is not commenced within 180 days from the date of such permit, or if the building or work authorized by such permit is suspended or abandoned at any time after the work is commenced for a period of 180 days. Based on the above, you are hereby advised to: Call the City of Tukwila Inspection Request Line at 206 - 431 -2451 to schedule for the next or final inspection. This inspection is intended to determine if substantial work has been accomplished since issuance of the permit or last inspection; or if the project should be considered abandoned. If such determination is made, the Building Code does allow the Building Official to approve one or more extensions of time for additional periods not exceeding 90 days each. Extension requests must be In wr1Nn2 and provide satisfactory reasons why circumstances beyond the applicants control have prevented action from being taken. In the event you do not call for the above inspection and receive an extension prior to 03/25/2007 , your permit will become null and void and any further work on the project will require a new permit and associated fees. 6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone: 206-431-3670 • Fax: 206-431-3665 ACTIVITY NUMBER: D06 -241 DATE: 06 -20 -06 PROJECT NAME: MONEY TREE SITE ADDRESS: 6720 FORT DENT WY X Original Plan Submittal Response to Correction Letter # Response to Incomplete Letter # Revision # After Permit Issued DE � S 306 Bitting Division Public Public Works t714/h4 W.a- A-00 DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete Comments: Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: TUES/THURS ROU ING: Please Route Structural Review Required REVIEWER'S INITIALS: APPROVALS OR CORRECTIONS: Approved ❑ Notation: REVIEWER'S INITIALS: Documents/routing slip.doc 2 -28-02 ~ .:PERMIT COORD COPY - PLAN REVIEW /ROUTING SLIP Fir e Prevention Structural Incomplete ❑ Approved with Conditions no Ala, (08.04 DATE: DATE: iLk (t Plann i g Division ni Permit Coordinator No further Review Required DUE DATE: 06-22-06 Not Applicable ❑ DUE DATE: 07-20-06 Not Approved (attach comments) n Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: License Information License BAKERCD066CZ Licensee Name BAKER CONSTRUCTION & DEV INC Licensee Type CONSTRUCTION CONTRACTOR UBI 600163145 Ind. Ins. Account Id Business Type CORPORATION Address 1 2711 E SPRAGUE AVE Address 2 City SPOKANE County SPOKANE State WA Zip 99202 Phone 5095353668 Status ACTIVE Specialty 1 GENERAL Specialty 2 UNUSED Effective Date 2/9/1994 Expiration Date 4/6/2008 Suspend Date Separation Date Parent Company Previous License BAKERC *074CZ Next License Associated License Business Owner Information Name Role Effective Date Expiration Date BAKER, BARRY N 01/01/1980 BAKER, DOUGLAS M 01/01/1980 GARBER. GEORGE J 01/01/1980 Look Up a Contractor, Electrir■an or Plumber License Detail Page 1 of 3 Washington State Department of Labor and Industries General/Specialty Contractor A business registered as a construction contractor with Led to perform construction work within the scope of its specialty. A General or Specialty construction Contractor must maintain a surety bond or assignment of account and carry general liability insurance. Bond Information Bond Bond Company Name Bond Account Number Effective Date Expiration Date Cancel Date Impaired Date Bond Amount Received Date TRAVELERS CAS & SURETY Until https: // fortress .wa.gov /lni/bbip /printer.aspx ?License= BAKERCD066CZ 07/12/2006 x x x x x x