Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Permit B93-0235 - MOHAWK CARPET - DEMISING WALLS AND DOCK LEVELORS
44S;;; (6) � emPe-r CERTIFICATE OF•OCCUPANCY CITY OF TUKWILA SOUTHCENTER BOULEVARD, SUITE'100 TUKWILA, WA$H,INGTON 98188 µ.' + VV'+ 'cp 4� P7 a e•,`.� Y+. THIS CERTIFICATE. IS :LtiE ,� F?UR$,UA ,T �T9 liLR:EO."UIREME IJS 10F S �'t 1 QN 307 OF THE UNIFORM BUILDING 7CERTIIJ Y,ING THAT AT THE ilrIME O •r ISSUANCE "THIS STRUCTURE WAS IN COMPLIANC WI'TH,� TFfE /�AIIOUS 4rORD'1NANCESrQF T t N Y RE(3UL) TING BUILDING CONSTRUCTION OR,/ SE ANi`i.AL. APPLICABLE ;C TY FIRES`GODES. OR THE 'FOLLOWING: Te 'n{ . rMOHAWK eC3ARPE f " Per�it t� "N 4r 3B93 ` . 235 �� �\'^y � �9A'c �. �.'� � S 8ui1dinq:Add ;s5t, ,82SS �EGRLE PARK U�R B, '911' � `+ 4 r:; 5'2304- 9.1.19. ,» . ° •.. ttc� /0 GALE ;MAR IO •A... a,�.,� upanc-y� : WAR EHdU E pM 0ccupantak L c d Occupar Gno.up: 8- , >1... ,... •_.:,.jy Type of °'Co 't: "tyry I ,n Y'!.5Y4'.X:ssa..AAAiii lit DI `•PREMISES • City of 71thwlli (206) 431 -3670 Community Development / Public Works • 6300 Southcenter Boulevard, Suite 100 • Tukwila, Washington 98188 BUILDING PERMIT Permit No: Type: Category: Address: Location: Parcel #: Zoning: Type Const: Gas /Elec: Wetlands: Water: B93 -0235 BPA -TI ACOM 18255 SEGALE PARK DR B 352304 -9119 III -N TUKWILA Contractor License No.: SEGALBP151M5 TENANT OWNER CONTRACTOR CONTACT MOHAWK CARPET 18255 SEGALE PARK DR B, SEGALE MARIO A PO BOX 88050, TUKWILA SEGALE BUS INESS.'PARK P.O. BOX 88050, TUKWILA' WA 98138 STEVE NELSON P.O. BO)( 88050, ' TUKWILA, WA 98138 Status: ISSUED Issued: 07/07/1993 Expires: 12/22/1993 Type of Occupancy: WAREHOUSE Slopes: N Sewer: TUKWILA TUKWILA, A 98188 A ....981:8.8 one: 206575 -3200 Ph'otie:: 206 575 -3200 ****************` ** *' * *: * * *M7( * * *, * * * * *. * *, * * * ** ***7* * * ** * * * *; *** * * *` * *. * * * * * * ** * * ** Permit Descr;, INSTALLxTWb ,DEMISING WALLS.''AND DOCK'S LEVELORS. SETBACKS. Units: 001 L ). Fire Prote=cton,;;: '` i' SPRINKLERED UBC Edition: 1991; Front: . "0 Back: Left: '0 Right": 1, t '�� Valuation . 10., 600,`:00 y-,; f , } .;Total', P�erinit Fee: 2f2 V140 * * * * * * * ;0,1<* �r *_** *), *0,*' i,, * * * *�k, *.'k */t ;( * * *kilo444k;,4,J(.1,./( r* * * * * * * *. **4(** *,4.Xi*k * ** Permit Center Authori zed,Si gna'ture I herebyoert i,fyf that. I have read and exam:i.ned this -•;permi t and know; the . same to b,e' ',true „avid correct . All provisions �'o`f "law ;,and'; ordinances governing` t�iis± vo.r.k will be complied with, whethert,spec'ified,,herein or not a> e ti � ., ; it 1 'S, The granting {,l.pf thins permit does not/Ores ume. to;,giv,e� °-authority to- violate or cancel thet�`p,rovis,ions of :any other" state or local laws' reg,ul_iating construction =o;r, }the Nerformance of work. I am authorized to: gn for and Signature; Print Name: This permit shall become nul" 1`'` and'.,v:o;;isd;;;;jrf. "'ti;`:eH WOrk is not commenced within 180 days from the date of i s'suance, o`r " " "i "f` the work is suspended or abandoned ".for a'per.iod of 180,days from the last inspection.. CITY OF TUKWIL. Department of Co.., nunity Development — Permit Cent(. 6300 Southcenter Boulevard - #100, Tukwila, WA 98188 (206) 431 -3670 Building Permit Application Tracking PLAN CHECK NUMBER X13- Da35 -.PROJECT NAME CONTACTED SITE ADDRESS _____________i__:%,. ________.__.e__?____o3 DATE NOTIFIED SUITE NO. INSTRUCTIONS TO STAFF • Contacts with applicants or requests for information should be summarized in writing by staff so that the status of the project may be ascertained at any time. • Plan corrections shall be completed and approved prior to sending to the next department. • Any conditions or requirements for the permit shall be noted in the Sierra system or summarized concisely in the form of a formal letter or memo, which will be attached to the permit. • Please fill out your section of the tracking chart completely. Where information requested is not applicable, so note by using "N /A ", date and initial. DEPARTMENTAL REVIEW "X" in box indicates which departments need to review the project. DEPART:ME BUILDING - initial review FIRE O PLANNING PROVED':; 0 Pe (ROUTED) /48'1 (.24Y-93 INIT: A-- 0)A CONSULTANT: UIREMENT. .......................... Date Sent - QMIUIEN Date Approved FIRE PROTECTION: Sprinklers FIRE DEPT. LETTER DATED: -.2_9- cf.) Detectors INSPECTOR: N/A S7 0 INIT: REFERENCE FILE NOS.: MINIMUM SETBACKS: N- s- E- Yes O PUBLIC WORKS N/A 6/��/93 UTILITY PERMITS REQUIRED? Yes No O OTHER BUILDING - final review BUILDING OFFICIAL INIT: PUBLIC WORKS LETTER DATED: INIT. REVIEW COMPLETED INIT: TYPE OF CONSTRUCTION: 111:14 CERT. OF OCCUPANCY? Xes No UBC EDITION (year): AMOUNT OWING: CONTACTED + ,� �� y�,.� � l...w'`C ' ' 1 DATE NOTIFIED BY: 2nd NOTIFICATION BY: (init.) 3RD NOTIFICATION BY: (snit.) 01/08/99 CITY OF TUKI4 Department of Community Development - Permit Center 6300 Southcenter Boulevard — #100, Tukwila WA 98188 (206) 431 -3670 Blanket Permit Tenant Improvement Application FEES (for staff use only) PLAN REVIEW NUMBER: �-- Da5M5 DESCRIPTION Project Name/Tenant: (10 , ( 0_ 17.e_- s- AMOUNT �p' G•0% RCPT # DATE Building Permit Fee Plan Check Fee j `; Ci C Building Use (office, arehouse, tc.): Nature of Occupancy (printing, manufacturing, etc.): • # W , / • APPLICATION MUST BE FILLED OUT COMPLETELY Building Surcharge 4,50 Square Footage - Entire Building: 0234 , -C Construction Area: 4i apd Tenant Space: -IT, ,c00 materials in the building ?o 0 Yes Will there be storage or use or flammable, combustible or hazardous If "Yes ", explain: l_— , �j'i %3e Blanket Permit n Agreement No.: f 3 - coo/ QQ11 Expiration Date: TOTAL - OQ (3,14 b Site Address: (25:5" . 1 ,ft. 191,..ivr '' g Value of Construction: $ /pi 4,oc) Project Name/Tenant: (10 , ( 0_ 17.e_- s- Assessor Account No.: al-cg 3p4/_ ,// 7 (interior) 0 Other: Type of Work: ® Tenant Improvement Demolition Describe Work to be Done: ��//����, iwrIz -- � Z. f- W a.. J -,-rc/ oLer_ (n/.3Y Building Type: Building Use (office, arehouse, tc.): Nature of Occupancy (printing, manufacturing, etc.): • # W , / • Will there be a change in use? © No 0 Yes If "Yes ", explain: 5id3f." WA State Contractor's License No.: SE6,gi. Square Footage - Entire Building: 0234 , -C Construction Area: 4i apd Tenant Space: -IT, ,c00 materials in the building ?o 0 Yes Will there be storage or use or flammable, combustible or hazardous If "Yes ", explain: l_— , Will there be ANY structural work? KNo 0 Yes If "Yes ", describe: Property Owner:'5ca% slHCss � Phone No.: 3�pv Organization: Address: ��p�-� p c City /State /ZipTu%�.;tcL (4 Phone No.: ,.5-757-,M00 (n/.3Y Contractor: e2fe ISJ Address: City /State /Zip Ti_ Ct lc. (4.44 Expiration Date: �_ q - 53 Phone No.: 57 3Zcd 5id3f." WA State Contractor's License No.: SE6,gi. �P)SI MS" ] %}j-(c Architect: 'fix t' &./5.vems Address: P��`7''� �- �) City /State /Zip: Ti..�(/u„�;(� [,�►�- �j'i %3e WA State Architect's License No.: Expiration Date: I hereby certify that I have read and examined this application and know the same to be true and correct, and 1 am authorized under Blanker Permit Agreement No. to apply for and obtain this permit. Signature: 14114--• Organization: • ' (c 112,-,r51 ►tix -s t7 -L Print Name: e.,Lycjo 12 (L}.egLINni Phone No.: 575 -3Z od Address: ?c gcle egg City /State /Zip: Th..r (c , k („ A 9 i i 31, See reverse side of application for specific plan submittal requirements and information. [Date application accepted: -Q.u- CO Date application expires: Ia - ,aL- 13 01/08/93 GENERAL INFORMATION This tenant improvement application may be submitted for non - structural interior construction which is authorized under an existing approved blanket permit agreement. It is the responsibility of the applicant to be aware and comply with all the terms and conditions as set forth in the agreement. The work is limited to that shown on the plans as submitted with this application, and such work is limited to non- structural interior construction only. The following work is not covered under the blanket permit process and separate approvals, permits and inspections are obtained through the applicable agencies. ELECTRICAL - Department of Labor and Industries (872 -6363) PLUMBING /GAS PIPING - King County Health Department (296 -4732) FIRE PROTECTION - City of Tukwila Fire Department (575 -4404) MECHANICAL - City of Tukwila Permit Center (433 -1851) RACK STORAGE - City of Tukwila Permit Center` (433 -1851) BUILDING PERMIT APPLICATION Application Submittal - Application and plans must be complete in order to be accepted for plan review. Make sure to fill out the application completely and follow the plans submittal checklist which follows. Handouts are available at the Permit Center which provide more in -depth detail on preparing the submittal. Authorized Agent - The applicant must be an authorized agent as Identified in the Blanket Permit. Fees - The permit fees are based on valuation of construction as declared by the applicant on the application, and shall include all the work to be covered under the permit. The valuation will be reviewed and is subject to revision by the Building Official to insure compliance with current fee schedules. To obtain a fee schedule, contact the Permit Center at 433 -1851. SUBMITTAL CHECKLIST ❑ Completed Building Permit Applicatbn ❑ Attachment #1 - Architects Statement ❑ Three (3) sets of construction drawings, which include: ❑ Site Plan, showing: O Building location on property O Adjoining public right -of- ways) O Parking layout O Location of tenant space or area of work within building O Overall dimensions of building O Overall dimensions of tenant space, or area or work O Name of each common wall tenant(s) and type of business or occupancy ❑ Floor plan of entire floor or tenant space that the work is taking place, showing: O Tenant space layout with use of each room labeled O All exit doors, corridors and egress patterns O All new walls, existing walls and proposed walls (provide construction. key) O Ail' other proposed construction ❑ Construction details O Construction key O Cross sections showing wall construction and method of attachment, floor and ceiling O Reflected ceiling plan (if applicable) ❑ Miscellaneous O 6" x 8" blank space provided on lower right hand comer of each page of plans (for use by the plan checker) O Title block on each sheet, Identifying: • Project name • Company job number (if applicable) • . Site address • Blanket permltagreement number • Architect, address and phone number O Each .sheet of plans stamped by a Washington State licensed architect O Minimum sheet size 18" x 24" O Plans must be drawn to scale and clearly dimensioned Drawings shall be prints which are clearly readable (original pencil or highlighted drawings are not acceptable.) ❑ Permit Fees (plan check fee, bLtiiding permit fee and state building surcharge) BLANKET PERMIT REE KE ERt�l11T AGREEMENT Tenant Improvement Temporary Inspection Card CITY OF TUKWILA Dept. of Community Development - Permit Center 6300 Southcenter Boulevard, Suite 100 Tukwila, WA 98188 (206) 431 -3670 Plan Review No. 0°13- 035 Date Issued: Blanket Permit A•reement No.: 93-00..91,N Li- CO Pro'ect Name /Job No.: 91.dc Cl/} -r -77/-0 Site Address: (75S 9'fe \2,, . >L ,-,,e 4 ,3" Suite No.: CALL FOR INSPECTIONS AT LEAST 24 HOURS IN ADVANCE (431 -3670) (have Plan Review number, Blanket Permit Agreement number, project name and site address read "x" .X REQUIRED INSPECTIONS APPROVED INSPECT PLANS DATE CORRECTION NOTICE ISSUED 1. Framing 2. Insulation 3. Suspended Ceiling Wallboard Fastening X4. DO NOT PROCEED BEYOND THIS POINT UNTIL THe BUILDING PERMIT IS ISSUED. PERMIT MUST BE PICKED UP WiTHIN 24 HOURS OF NOTIFICATION THAT THE PERMIT IS READY. CONTRACTOR /APPLICANT BEGINS WORK AT THEIR OWN RISK PER THE TERMS OF THE BLANKET PERMIT AGREEMENT. INSPECTIONS 1. FRAMING - After rough -in inspections such as mechanical, plumbing, gas piping, electrical and fire stopping is in place. 2. INSULATION - After framing approval, but before installation of wallboard. Baffles must be installed to keep attic ventilation points clear. 3. SUSPENDED CEILING - Fasten diffusers, lights and seismic bracing. 4. WALLBOARD FASTENING - Prior to taping (See UBC Chap. 47 and Table 47G). 5. PLAN CHECK INSPECTION - Immediately after the Tenant Improvement Permit is picked -up by the applicant.Work may not proceed until the City Inspector delivers the plans and new inspection card to the site. This inspection should be scheduled at the Permit Center when the permit is obtained. • Construction will not proceed past required inspections. • The Building Permit and approved plans shall be picked -up by the applicant within 24 hours of notification that the permit is ready. Failure to do so may result in a stop work order. • Construction may not deviate from that shown on the plans as submitted at time of application. • All corrections shall be undertaken within three (3) days of notification by Building Inspector, unless otherwise agreed to by both parties. • No more than 30 days shall elapse between the last required Inspection and the "Building Final." • Unauthorized occupancy and/or use of the remodeled area shall not occur until the Building Inspector completes the "Building Final," which takes place after the Building Permit and Permanent Inspection Card has been issued. • The City reserves the right to stop work at any time that in its judgment the work presents a safety problem, warrants a building permit prior to continuing work, is not proceeding according to approved plans, or otherwise would not qualify for consideration under the blanket permit process. • The following work is not covered under the blanket permit process. This work shall not start until approvals and permits are obtained through the applicable agencies, under their normal process: Electrical — Department of Labor and Industries (872 -6363) Plumbing /Gas Piping — King County Health Dept (296 -4732) Fire Protection — City of Tukwila Fire Department (575 -4404) Mechanical — City of Tukwila Permit Center (431 -3670) Rack Storage — City of Tukwila Permit Center (431 -3670) 1I special Inspections are required, work shall not proceed past where special inspection is required, or special inspections must be pre- arranged with Building Oificial. THIS IS A TEMPORARY INSPECTION CARD ONLY AND WILL BE REPLACED BY A PERMANENT INSPECTION CARD WHEN THE BUILDING PERMIT IS ISSUED. UNG 13LANKET PERMAT AGREEMENT Tenant Improvement Application Attachment 1 — Architects Statement CITY OF TUKWILA Department of Community Development - Permit Center 6300 Southcenter Boulevard — #100 Tukwila Washington 98188 Phone: (206) 431 -3670 PLAN NO.: REVIEW Oc EViVID BLANKET PERMIT AGREEMENT NO.: 5.3-cog 13PA SITE ADDRESS: ) ?a5.S Sc9t /c W+"c4c O-f-1 \le �3 PR OJECT NA H %fir a N-lJ- NAME /TENANT: COMPANY JOB NO.: 7 -O` Is any part of the work proposed under this application include structural work or affect structural components of the building? 0 Yes ®1 o If yes, has the structural work been authorized by the Tukwila Building Official to be included in this application? 0 Yes 0 No Does the proposed work comply with the requirements of Chapter 33 of the Uniform Building Code (1988 Edition)? erYes Q No If no, please explain: Street Address: �� 18ZSS �cs� /c ��r�C �n ve t3 City /State /Zip: —11-16.4.A c1/4. w4 -133 Will any special Inspections be required per Chapter 3 of the Uniform Building Code (1988 Edition)? 0 Yes erko It yes, list specific inspections: As a result of this proposal, does the parking meet the requirements of Tukwila Zoning Code parking requirements? t; Yes 0 No If no, please explain deficiency: ' ' Architect/Engineer Stamp: Archltect/Engineer Signature: ormr,i.,,, Print Name: `"),A, N 4 ( ��are w 4326 REG 1 STE ED ARC iTE T l A 4Y REN TATE OF WASHINGTON ' r ; Firm Name: ?(4- C. �c�e tislwosS Business Phone: S �S_ az(3c Street Address: �� 18ZSS �cs� /c ��r�C �n ve t3 City /State /Zip: —11-16.4.A c1/4. w4 -133 f• 19 .1'.. ..... %��S,'.7ira..t;i ?'''�hr' , r' -f: r'r •.•1 **** h***.**: k***** k***: k****• k****;** k* h***• k * * *h * *h * *k' * * ** *•k * *kk:k ** *k.. CITY: Of TU{(WIIA, !?!.A .. TRANS,MIT. '' * *kkk */ *******k tk,* k*> 4* ti4*********** h**** * * **k * * *. * * *k*k. *.k,k * * * *k * *k.* TRANSMX. T-:: Number»:.930O0809.;'Amautrrta 212.40 06/24/93 .15i17 Permit .•Nav`.053•�023; Type: 13;P(4 -TI 'OU.ILDTNG PERMIT" Parcel.: No:.,352304- 9i.19 01448/913 S ite; Addrasa:" 1825 SEGALE . PARK(:, BV -13 13 Pay,merit::tle,t,hlad I ! :CHECK Natat i on S,EGFIL.E, BUSINESS x ri i t:: SL13 h****** 4*'****'***. *, * *. * * * * * *•h* * * ****** *A* *k * ** tilt* *4* ** ***** ** ** * **, *•k Arrautrtt` Cade Det;cr -Iptian 000/322.100 BUILDING :_ :NONRES 000/345.830' PLAN. CHECK NGNR .S 000/38,8.901, STATE BUILDING SURCHARGE fatal `(1'M9 ; Pay ierit)a'. GENERA .126.00 GENERA 81.90 GENERA 4.50 TOTAL 212.40 CHECE(, 2i".40' CHANGE 0.00 191AQ00., :15 :57', CITY OF TUKWILA. Address: 18255 SEGALE PARK DR B Tenant: MOHAWK CARPET Type: BPA -TI Parcel #: 352304 -9119, * * * * * ** * * *' loft * ** ***** ** *** ********* * ** * * *•k *•k•k** **•*'k *kk *•** *** *fir * * *k * * *** * *k* Permit Conditions: ...— 1. No changes wi 1 1 be made.:�to ie5�Lpwlans'a Unless ...approved by the Architect and the 'T,uk`w1�,1�,a` °b ail "ding "'Div "isioh.. . 2. Electrical permit Shia ( "1wRbe obtained ".through� "`the `;Wash i ngton State Dlvisiori� ofP,:Labor� ,?,d1 Industries ands al 1 ele, strsical work will be/yi pecteyo b .:that ;agenc�% (248 ,6(, ,,x7) :`' E v }if �'Y n�.tt S+ ij 3. All permits; .inspectjon, records, .and a'"pprovl�eZd��'p1ans "shati1,1 be maintained,avaiiab'1eh�,at the' job site prior to the star Z,ld any construct�lon�;�, ",These�ffdocument,s a are to "be mai,ntai"h,ed `, ava i 1 aM � 'until ,f t;na l� i nspect5;i,on .a iprova l i s '•gran;ted 6 4. Any e p ed instil ba�c `iing mate�r,ia1 sha11 have .a;F1ame � tt= Sprea1d atillg of 25 or �1,e,ss, and material shall bear i''die 'nti: f i ca �ioh showing�:.�the f 1t e performance rating thereof Xt ,_ 5'. 5. A 1 1 ;'efm3,its, '1ns,'pectiorr,,.recor1s,. "and ;approved plena, sha1L be mai stained A/ai�lable at - the.. j''ob site prior to the start .of, any �`i'onstruc'tin. These,i, ocu,m'ents ;are°w"io —.be maintained`''`` avat1i6ble until final `lnspecl t'io! ap;phQva�1 ,,..is, granted. „, 6.. Al 1J lronstruct l'on "=to be \d r.) ,,�i n cornfor nce with approved tN p 1 a a'n d. q ,, n ,: Y ,� ..p , 1� di m y (199'1' z ..f � cxe u i r�eme ts`�o "f fie Un i f or u�i °1.� .i' Code Ed i t lPon) a,s' amended by,� the Wash i ngton x_,S-ta'te'Bu it d i ng ,Codex, r1 Unit 'r rn echan i caVl ode (1'9�9a1` ,;Ed,i tl on.)•�,,:� and' Washington State, E n e CodeV s 1 ;9 91 S eoro�q, `.E�d'i t i o n,) ,., , ,, } , `'`� t Val t c f enmi t. The i ssuanceYof as per.•mi t.s. r approval of Y plane, s .ec ficetions and computet.ons�`s ,a°l-i not be,,1corl ,, struel to. bra'' permit for,. or' an 1 p.rov�al \`of,��gny violation of an� f ,Pe prcif i si ons of the pate Buiil `i;r.�g $Code or 'any ordinar . of the jurisdiction. o per ,it Iresumsing to give z w . Alb 1� G^ki „ys r. ,� authority for violate l nor cancel the pro ,i{ .l ons of this code' shall b v lid., `.. r r �- There shad be r o occupanrc.,y of the bui'1 diing(s) unt1'11 t,h,, final i nsp on has been cofipl.e.ted :b the: Tukwia1 a Bu;l,14,l ng. Inspector. "^,v +` ar a.,` 9. A CERTIFICATE\\ CCUPANCY W .` �6 �JIRED FOR TTHI ;.PERMIT. 'Permit No: B93 -0235 Status: ISSUED Applied: 06/24/1993 Issued: 07/07/1993 City of Tukwila FIRE DEPARTMENT 444 Andover Park East Tukwila, Washington 98188 -7661 (206) 575 -4404 Fire Department Review Control #B93 -0235 (510) John W. Rants, Mayor June 29, 1993 Re: Mohawk Carpet - 18255 Segale Park Drive B Dear Sir: The attached set of building plans have been reviewed by The Fire Prevention Bureau and are acceptable with the following concerns: 1. The total number of fire extinguishers required for your establishment is calculated at one extinguisher for each 3000 sq. ft. of area. The extinguisher(s) should be of the "All Purpose" (2A, 10B:C) dry chemical type. Travel distance to any fire extinguisher must be 75' or less. (NFPA 10, 3 -1.1) Extinguishers shall be installed on the hangers or in the brackets supplied, mounted in cabinets, or on shelves (NFPA 10, 1 -6.9), and shall be installed so that the top of the extinguisher is not more than 5 feet above the floor. (NFPA 10, 1 -6.9) Extinguishers shall be located so as to be in plain view (if at all possible), or if not in plain view, they shall be identified with a sign stating, "Fire Extinguisher ", with an arrow pointing to the unit. (NFPA 10, 1 -6.3) (UFC 10.505A) Clear access to fire extinguishers is required at all times. They' may not be hidden or obstructed. (NFPA 10, 1 -6.5) Maintain fire extinguisher coverage throughout. 2. No point in a sprinklered building may be more than 200 feet from an exit, measured along the path of travel. (USC 3303(d)) City of Tukwila FIRE DEPARTMENT 444 Andover Park East Tukwila, Washington 98188 -7661 (206) 575 -4404 Page number 2 John W. Rants, Mayor Exit doors shall swing in the direction of-exit-travel when serving any hazardous area or when serving an.. occupant load of 50 or more. (UBC 3304(b)) Exit doors shall be openable from the inside without the use of a key or any special knowledge or effort. Exit doors shall not be locked; chained, bolted, barred, latched or otherwise rendered unusable. All locking devices shall be of an approved type. (UFC 12.106(c)) obstructions, including storage, shall not be placed in the required width of an exit, except projections as permitted by the Building.Code. Exits shall not be obstructed in any manner and shall remain free of any material or matter where its presence would obstruct or render the exit hazardous. (UFC 12.104(a)) .Dead bolts are not allowed on auxiliary exit doors ,unless the dead bolt is automatically retracted when the door handle is engaged from inside the tenant space. Exit hardware and marking shall meet the requirements of the Uniform Fire Code. (UFC 12.106-12.111) internally illuminated exit signs shall have both bulbs working at all times. (UBC 3314(c)) When two or more exits from a story are required, exit signs shall be installed at the required exits and where otherwise necessary to clearly indicate the direction of egress. (UBC 3314(A)) Aisles leading to required exits shall be provided from all portions of buildings. The width and spacing of aisles shall be maintained at all times. (UFC 12.104(b)) Manually operated edge or surface mounted flush bolts and surface bolts are nrohihited_ (urn 12.106( )1 City of Tukwila FIRE DEPARTMENT 444 Andover Park East Tukwila, Washington 98188 -7661 (206) 575 -4404 John W. Rants, Mayor Page number 3. An approved automatic fire sprinkler extinguishing system is required for this project. (City Ordinance #1646) All sprinkler system plans, calculations and the contractors Materials and Test Certificates submitted to The Tukwila Fire Prevention Bureau must be stamped with the appropriate level of competency seal. (WAC 212 -80) All new sprinkler systems and all modifications to existing sprinkler systems shall have fire department review and approval of drawings prior to installation or modification. New sprinkler systems and all modifications to sprinkler systems involving more than 50 heads shall have the written approval of the W.S.R.B., Factory Mutual, Industrial Risk Insurers, Kemper or any other representative designated and /or recognized by The City of Tukwila, prior to submittal to the Tukwila Fire Prevention Bureau. No sprinkler work shall commence without approved drawings. (City Ordinance #1646) Hose racks must remain unobstructed to allow the rack to swing freely. (UFC 10.504) Sprinkler protection shall be extended to all areas where required, including all enclosed areas, below obstructions and under overhangs greater than four feet wide. (NFPA 13- 4- 4.1.3.2.1) Contact The Tukwila Fire Prevention Bureau to witness all required inspections and tests. (UFC 10.503) (City Ordinance #1646) Refrain from blocking sprinkler coverage with shelving. NFPA standard #13 states that any shelving or decks in excess of 4 feet in width will require . installation of sprinklers thereunder. IdnifAnn CnllrrAG (Ceinh' n rn11 -nn r1,,,,r■ mnfr...el cr,,! City of Tukwila FIRE DEPARTMENT 444 Andover Park East Tukwila, Washington 98188 -7661 (206) 575 -4404 Page number 4 John W. Rants, Mayor 1 combustible material located above the ceiling must be provided with sprinkler protection. (UFC 10.501(a)(b)) Sprinklers subject to mechanical injury shall be protected with listed guards. (NFPA 13- 2 -2.6) 4. All electrical work and equipment shall conform strictly to the standards of The National Electrical Code. (NFPA 70) Each circuit breaker shall be legibly marked to indicate it's purpose. (NEC 110 -22) 5. Material safety data sheets for all hazardous materials on the premise shall be readily available on site for emergency personnel. (UFC 80.106) 6. Required fire resistive construction, including occupancy separations, area separation walls, exterior walls due to location on property, fire resistive requirements based on type of construction, draft stop partitions and roof coverings shall be maintained as specified in the Building Code and Fire Code and shall be properly repaired, restored or replaced when damaged, altered, breached, penetrated, removed or improperly installed. (UFC 10.601) 7. Your street address must be conspicuously posted on the building and shall be plainly visible and legible from the street. Numbers shall contrast with their background. (UFC 10.301(a)) 8. Warehouses designed for high -piled stock shall establish and maintain aisieways of not less than 44 inches to provide access.to all exits and fire department access doors. (UFC 81.108) 9. Storage may not be closer than 36 inches in all directions to ceiling - hung "Space or Unit" heaters. (UFC 11.404) City of Tukwila FIRE DEPARTMENT 444 Andover Park East Tukwila, Washington 98188 -7661 (206) 575 -4404 Page number 5 John W. Rants, Mayor 10. Storage may not be closer than 18 inches below.' sprinkler heads. (NFPA 13, 4 -2.5 and NFPA 231.5 -1) 11. Foam rubber - backed carpet and foam padding shall be stored in separate areas away from other carpeting. Foam rubber - backed carpet and foam padding shall not be stored higher than 6 feet. Storage higher than 6 feet will require the installation of "In- Rack" sprinklers. Foam rubber- backed carpet and foam padding when intermixed with regular carpet shall be treated the same as "All Foam ". (UFC Article 81) 12. The critical storage height for high -piled combustible stock in closely packed piles is 15 feet. (UFC 9.110). Storage above 15 feet would necessitate increasing the sprinkler density to extra hazard (UFC 81.105), and adding smoke removal capabilities. (UFC 81.107) 13. To use any building or portion thereof exceeding 2,500 square feet for the storage of high -piled combustible stock. A floor plan showing the dimensions and location of the stockpiles and aisles shall be submitted with applications for such permits. (UFC 4.108(h3)) 14. In double row racks with heights of storage up to and including 25', an average nominal 6" transverse flue space between loads or at rack uprights shall be maintained. (NFPA 231C 4 -3.1) 15. High -piled combustible storage is combustible materials in closely packed piles more than 15 feet in height or combustible materials on pallets or in racks more than 12 feet in height. For certain special- hazard commodities such as rubber tires, plastics, some flammable liquids, idle pallets, etc., the critical pile height may be as low as 6 feet. (UFC 9.110) 16. Flammable or combustible liquids that are used in excess of 10 gallons total, must be stored in metal storage cabinets. No more than 120 gallons may be stored in any one cabinet (60 aallons of class 1 or 11 flwmmmhla City of Tukwila FIRE DEPARTMENT 444 Andover Park East Tukwila, Washington 98188 -7661 (206) 575 -4404 Page number 6 John W. Rants, Mayor liquids). Cabinets shall be conspicuously labered "FLAMMABLE - KEEP FIRE AWAY ". Cabinets shall have a 2" high liquid tight lip for spill containment and shall have self - closing doors. (UFC 79.202(c)) (UFC 79.202(2)(3)(b)(c)) Inside storage of flammable or combustible liquids in excess of 240 gallons total, shall be stored in flammable liquid storage room or liquid storage warehouse designed and constructed in accordance with the Building Code for a Group H, division 3 occupancy. (UFC 79.202(b), UFC 79.203(a) and 79.204(a)) Inside storage of flammable and combustible liquids (IN CLOSED CONTAINERS) shall not exceed 60 gallons of class I -A, 120 gallons of class I -B, 180 gallons of class I -C, 240 gallons of class II or 660 gallons of class III -A liquids, or 240 gallons in any combination of class I and class II liquids. (UFC 79.201e) In areas covered by a sprinkler system designed for extra- hazard occupancies, the inside storage of flammable and combustible liquids (IN CLOSED CONTAINERS), shall not exceed 120 gallons of class I -A, 240 gallons of class I -B, 360 gallons of class I -C, 480 gallons of class II or 1320 gallons of class III -A liquids, or 480 gallons in any combination of class I and class II liquids. (UFC 79.202(a)) 17. A permit is required for the use, storage, handling or sale of flammable or combustible liquids. (UFC Article 79) 18. A permit is required to use any building or portion thereof. exceeding 2500 square feet for high -piled combustible storage. (UFC Article 81) 19. A permit is required to install or maintain an LP -gas container or operate LP -gas vehicles. (UFC Article 82) 20_ Thic raviaw 14m4+-.ar+ fn enanfilnf4va f annn+ ennnu nnlw City Of Tukwila FIRE DEPARTMENT 444 Andover Park East Tukwila, Washington 98188 -7661 (206) 575 -4404 John W. Rants, Mayor - special f ire permits may be necessary depend i rig_ o detailed description of intended use..: Any overlooked hazarclous condition and/or violation Of the adopted Fire or Building Codes does not imply approval of such condition or:violation. C INSPECTION RECORD Retain a copy with permit CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206) 431 -3670 Project: t b , Auit Type of Inspect �' , 17 N 4-1-- . � m reS9: ss jQ ., .. ' I . � e form:: Special Instructions: 1 Date wanted: / 2/2 3/13 am. . Requester: `� I '"~ '-- Phone No.: /Vproved per applicable codes. COMMENTS: ' ❑ Corrections required prior to approval. ❑ $30.00 REINSPECTION FEE REQUIRED. Prior to reinspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Cali to schedule reinspection. ,f 4� INSPECTION RECORD Retain a copy with permit CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206) 431 -3670 .r° : : "44 ca 4 iJ/Ppe i� 0 nSp@Ci n� `- PGti.! � J A�'li� Address: .2s r. �^ev,; 0� /} J�/ Date Called: ?„ 2 a - - 3 Special Instructions: t Date Wanted: 7- 3- _i : Requester: �am.;.INn,, Phone No.: . 7 ,-. -3 a Approved per applicable codes. COMMENTS: ❑ Corrections required, prior to approval. br� ,- 6,-4_ "...Jr, /l eovi) ❑ $30.00 REINSPECTION FEE REQUIRED. Prior to reinspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Calf to schedule reinspection. Dale: 0. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 INSPECTION RECORD 0 Retain a copy with permit B'13-oa35 PERMIT N0. (206) 431-70 ro ect: TO e WK Co,x 4-...r, YID o ns.: «ion: I 7lY ress: ��a t�.:.D 3 Spedal nstn►ctions: * Date anted: "1-33 ,n3 `I pm: Requester: ll ,, Phone No.:`l - 3ao0 Approved per applicable codes. ❑ Corrections required prior to approval. COMMENTS: nspector: 7- 1.4 - �3 must be paid at ❑ $30.00 REINSPECTION FEE REQUIRED. Prior to reinspection, fee 6300 Southcenter Blvd., Suite 100. Cali to schedule reinspection. s, a. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 INSPECTIOI4. RECORD 0 "Retain a copy with permit 1313- °ZS PERMR NO. (206) 431 -3670 .r•e «: )mo haw k C.u.rpp ypeo ns.:« .n.. IGli"iiC- r "ei Address: 1 y �r fr . & Q- r t �- 'y �a e .:.: 1.,,,, --7 "' C .-,. Sp: «. nstructions: Date Wanted:. —I • c am. p.m. Requester: Phone Approved per applicable codes. COMMENTS: 0 Corrections required prior to approval. [in O $30.00 REINSPECTION FEE REQUIRED. Prior to reinspection, tee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection: Receipt No.: o. INSPECTION RECORD Retain a copy with permit CITY OF "TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 Project: 0 ri b I A. (/4„.. I n ,, YPe o ns n: fv. Address: j , s-s-- K pit Date Called: Special Instructions. � f!. /r Date Wanted: G �'' � ...5 am. p.m. Requester. Phone No.: G -7 5.- .22 7 VApproved per applicable codes. COMMENTS: ❑ Corrections required prior to approval. G v , c.� t"b4 5,04z- a K)T X114 f rv►r3(1 ,y 1 Srr tvM,.L , nspector: 7 �3 ❑ $30.00 REINSPECTION FEE REQUIRED.` Prior to reinspection, fee must be paid at 6300 Southcenter Bivd., Suite 100. Cali to schedule relnspection. INSPECTION RECORD Retain a copy with permit CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206) 431 -3670 Project: rOjeCts Type of Inspecfbn: k.tom, tae .:•; Spec Instructions: �on it1G�, k�e acr�� �kh-e S�r��e. -E- a-� . Date Wanted: , Q i9 CJ -(43 rm p,m. Requester: :lc�r1 �O.-tr o P l,a,e Approved per applicable codes. 0 Corrections required prior to approvai.,f �. 0 $30.00 REINFECTION FEE REQUIRED. Prior to reinspection, fee must be paid at 6300 Southcenter Blvd., Suite 100; Call to schedule relnspection. • INSPECTION. RECORD 0 Retain a copy with permit CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 PERMIT N0. (206) 431 -3670 Project: Oho) CUY Type of inspection: T GiYIl Address: X1c : 3 Q. Pk a)(3 Date Called: W " o �4- 5 Special Instructions: Dpn Yn 4.11 :krQ.e. b.2 OLrc 6 c P,4P3 Date Wanted: rr ,,,, lU'Q 5, q.33 p.m. Requester: n ---1---aila Approved per applicable codes. ED Corrections required prior to approval,, F. D $30.00 REINSPECTION FEE REQUIRED., Prior to reinspection, tee must be paid at 6300 Southcenter Blvd., Suite 10o. Call to schedule reinspection. SERIES ilansumumor KELLEY Nirr Kelley Dyna'LoadTM Mechanics! Dockieveler Summary of features ▪ Heavy -duty extension spring, counterbalance system with single adjustment point • Exclusive walk -down lip extension 1 Automatic retracting legs for full unrestricted working range: operator adjustments are not required for below dock operation 3 Self - cleaning lug -type lip hinge with lifetime warranty 1 Fixed rear hinge — no pinch, point • 1 Working range yellow toe guards 1 Integral maintenance strut holds ramp in raised position for service or cleaning 1 Includes two heavy -duty dock bumpers SERIES • Nimmomomir KY Specifications Dyna -LoacP W Series Mechanical Dockieveler Architectural Specifications (short form) Adjustable dockievelers to be S long x wide, 23,000 Ib. or-3(11ee84b. capacity per ANSI MH14.1 -87. To be fully mechanical, requiring no manual lifting to operate. To be spring counterbalanced. Lip to automatically extend. Hinged legs to provide full rated capacity support at dock level to allow lowering of ramp below dock level without extending Hp. Full working (service) range yellow toe guards and two heavy -duty dock bumpers. To meet U.S. Department of Commerce Standar C.S. 202 -56. To bekelley *del Lf2IN as distributed by I'iIC1 uipwtrriT Models (capacity Model M605W M606W M608W M706W —3 M708W (capacity Model M636W • M638W M736W Duty Ranges to 23,000 lbs. per ANSI MH14.1 -87) Width Length Shipping Weight 6' 5' 1200 lbs. 6' 6' 1285 lbs. 6' 8' 1545 lbs. 7' 6' 14501bs. 7' 8' 1850 Ibs. Duty Range II to 36,000 lbs. per ANSI MH14.1 -87) Width Length Shipping Weight 6' 6' 7' 6' 8' 6' 1570 lbs. 1840 lbs. 1685 lbs. M738W 7' 8' 2125 lbs. All models also avlalable in 6'6" width, Consult factory. Actual life of any dockleveler is dependent on gross load weight, weight distribution, angle of incline, type of forklift truck, number of forklift truck wheels and type of tire, and speed of forklift truck. Proper application based on actual operating conditions can be made by use of Kelley Dyna -Load dockleveler rating system by an authorized Kelley Company, Inc., sales representative. Operation Y Pulling chain releases hold -down mech- anism. Dockieveler rises, lip remains pendant behind protective bumpers. o Operator walks out on ramp, lowering it to truck bed. Up automatically extends and locks during first few Inches of downward movement. • Loading /unloading proceeds. II When truck pulls away from dock, lip automatically retracts to protected position. 1 In stored position, ramp is fully supported by dock level support legs. Construction E Unitized ramp with 55,000 PSI yield deck and 50,000 PSI yield beams and INX50 lip. • Self - cleaning, lug -type lip hinge with lifetime warranty. ■ Fully welded subframe. III Double -pawl hold -down mechanism. ■ Fixed rear hinge provides 4" of side -to- side tilt without forming gap at rear hinge. Working (service) Range 24 ", from 12" above dock to 12" below, Optional Features ■ Manually retracting legs. • Full operating range yellow toe guards. ■ Foam insulated ramp. • Abrasive skid - resistant ramp and Hp surface. • Galvanized (spray metalized) ramp, lip and frame. • Smooth plate deck and lip. • Eighteen Inch lip. Recommended for use when servicing refrigerated vans. NOTE: Longer lip reduces capacity and working range. • Black and yellow striped toe guards, • Minimum lip bend for use with material handling equipment with low under - clearance. NOTE: Minimum Hp bend may reduce working range. Accessories • Truk Stop" truck restraining system. • Truk Alert illuminated loading dock communications package. • Panic Stop' emergency safety system. • Curb angle sets. ■ Side and rear weatherseal. " II Self- forming pans. i Self - contained frames. Consistent with our policy of continuing product Improvement, we reserve the right to change these specifications without notice or obligation. 01889 Kelley Company, Inc. Utho In USA Form No :10.691 Kelley Company, Inc. 6720 N. Teutonia Avenue Milwaukee, WI 53209-0993 TEL: (414) 352 -1000 FAX: (414) 352 -2093 TELEX: 26.661 HYDRAULIC DOCKLEVELER MODEL PHASE NUMBER AND GAUGE OF WIRES TOTAL NUMBER OF WIRES 12 GA. 14 GA. ..W„ 10 3 — 3 30 — 4 4 HK„ 10 3 2 5 30 • — 6 6 "K" with Performance Package 10 •' 3 5 8 30 — 9 9 DOCKLEVELER PIT DETAILS CONDUIT RUN AND RECEPTACLE LOCATION — HYDRAULIC DOCKLEVELERS ONLY (NUMBER AND SIZE OF CONDUITS MAY VARY WITH LOCAL CODES) r' 1 r4 11 II II 11 p I 1 1 II HYDRAULIC DOCKLEVELER CONTROL BOX 3/4" dia. ANCHOR BOLT, FIELD INSTALLED — SUPPLIED BY OTHERS 3/4" SIDE OF PIT TO SIDE OF BUMPER MOUNTING PLATE 2 LAMINATED BUMPERS FURNISHED BY KELLEY COMPANY, INC. UMPER MOUNTING ANGLE LOCATION FOR AND TR HYDRAULIC DOCKLEVELE CONTROL BO TRUK STOP CONTROL BO NOM. DOCKLEVELER SIZE 6hc5' (Sht6' PIT LENGTH -DIM. "A" 52" 64" PIT WIDTH DIM. "B" 74" 74" PIT DEPTH — Rear DIM. "C" 231i" 231/2" PIT DEPTH — Front DIM. "D" 24" 24" CURB ANGLE — Front DIM. "B►► 74" 74" CURB ANGLE — • Rear DIM. "E" 80" 80" CURB ANGLE — Side DIM. "F'► 49" 61" CURB ANGLE — Bumper DIM. "G ►' 21" 21" NOTES: 1) For Hydraulic Docklevelers see 2) See Kelley Drawing No. 10 -655 DOCKLEVELER PIT DETAILS DUIT RUN AND EPTACLE LOCATION — RAULIC DOCKLEVELERS ONLY MBER AND SIZE OF CONDUITS VARY WITH LOCAL CODES) HYDRAULIC DOCKLEVELER CONTROL BOX UMPER MOUNTING ANGLE LOCATION FOR HYDRAULIC DOCKLEVELER LOCATION FOR SINGLE CONTROL BOX AND TRUK STOP CONTROLS HYDRAULIC DOCKLEVELER CONTROL BOX----- ---.45 TRUK STOP CONTROL BOX -13" FOR DOCKLEVELER OR TRUK STOP CONTROL BOX- •�,j�` ANCHOR LAYOUT FOR CURB ANGLE CITY OF TUKWILA APPROVED JUL 1993 BUILDING 1 ISION 12 "--el • 14-12"--0.14-12"—•131*— 4E116. CONCRETE ANCHORS, 1 /2" dia. 6" lg., LOCATED AS SHOWN NOM. DOCKLEVELER SIZE 8'x5' 61c6' 8'x8' 8'x10' 6'x12' 6.5'x6' 6.5'x8' 6.5'x10' 6.5'x12' 7'x :' 7'x8' 7'x10' 7'x12' PIT LENGTH DIM. "A" 52" 64" 88" 112" 136" 64" 88" 112" 136" 8 • ' 88" 12" 138" PIT WIDTH DIM. "8" 74" 74" 74" 74" 74" 80" 80" 80" 80" 8." 85" : " 85" PIT DEPTH — Rear DIM. "C" 231/2" 231" 231/2" 231/2" 28" 231/2" 231/2" 231/2" 26" c3" 231/2" 2 " 28" -PIT DEPTH — Front DIM. "0" 24" 24" 24" 24" 261/1" 24" 24" 24" 281/2" 24" 24" 2 ''' 261/2" CURB ANGLE — Front • DIM. "B" 74" 74" 74" 74" 74" 80" 80" 80" 80" 85" —85" 86 85" CURB ANGLE — Rear DIM. "E" 80" 80" 80" 80" 80" 86" 86" 86" 86" 91" 91" 91 ' . 91" CURB ANGLE — Side DIM. "F" 49" 61" 85" 109" 133" 81" 85" 109" 133" 61" 85" 10' ' 133" CURB ANGLE — Bumper DIM. "G" 21" 21" 21" • 21" 21" 21" 21" 21" 21" 21" 21" 21 21" NOTES: 1) For Hydraulic Docklevelers see Kelley Drawing No. 10 639 for Electrical Requirements and 2) See Kelley Drawing No. 10 -655 for Cantilever Pit Detail. 59 a grams. 03) seaALE. E3USIINIESS PARK ( 4o041.\•/ December 16, 1993 Mr. Bob Benedicto City of Tukwila Building Departtnent 6300 Southcenter Boulevard, Suite 100 Tukwila, WA 98188 -%32 Re: Permit #B93 • Dear Bob: Per Duane's request, enclosed are two (2) copies of drawing No 1 for the Mohawk tenant improvement. The revised drawing shows the modified detail for the demising wall between Mohawk Carpet and NDC. If you have any questions, please call me at 575-2000. Very truly yours, SEGALE BUSINESS PARK Steve Nelson dk Enclosures RECEIVED PERMIT CENTER DEC 2 0 1993 COMMUNITY DEVELOPMENT. RO: BOX 88050 II TUKWILA, WASHINGTON 98138 III TELEPHONE 206 575-2000 IIII FAX 206 575-1837 M E M O John W. Rants, Mayor Department of Community Development Rick Beeler, Director DATE 12/16/93 TO Steve Nelson FROM Bob Benedicto SUBJECT Mohawk Carpet, Inc. # OF PAGES 1 I have reviewed the approved plans for the Mohawk Carpet tenant 'improvement •and:agree that no fire rated occupancy separation wall is required,between. Mohawk Carpet, Inc . and•the adjacent tenants (provided that the occupancies remain. "B -2"' on each side of the. demising walls). Consequently,. a non bearing demising. wall with 5/8" gypsum wallboard:.on one side would be acceptable for,: this•tenant space. • . • Please. maintain this•memo with permit , documents for the .final. inspection. Our file has been noted to reflect the.;change to.the: demising wall detail. 6300 Southcenter Boulevard, Suite #100 Takwila, Washington:'. 98188 •:(206) 01.3670 SEGALE EILISINESS PARK December 13, 1993 •Mr. Duane, Griffin City of Tukwila Building Department 6300 Southcenter Boulevard, Suite 100 Tukwila, WA 98188 Re: Permit #B93-0325 Dear Duane: The Mohawk tenant improvement permit will expire on January 19, 1994 per your letter dated December 2, 1993. To finalize this permit, the demising wall section between Mohawk Carpet and National Distribution needs to be modified due to limited accessibility caused by product storage. The wall section on the plans calls for 5/8" gypsum wall board on both sides of the wall. I need to • eliminate the installation of wallboard on the National Distribution side (south side) to complete the • project under the current time limits. Mohawk Carpet and National Distribution are both B-2 occupancies and a rated separation between them is not required per code. I am requesting that the plans be modified to show the installation of gypsum wall board on the Mohawk Carpet side of the wall. With this modification, we can call for final inspection. If you have any questions, please call me at 575-2000. •Very truly yours, SEGALE BUSINESS PARK Steve Nelson • dk , • • • ' ' ' • "Y•,"; aAmolmipatt.lir fl,Q.E!YED DEC 21 (E.19$13 COMMUNITY DEVELOPMENT P.O. 130X 88050 1 TUKWILA, WASHINGTON 98138 TEL 206 575-2000 1 FAX 206 675-1837 Dec 02, 1993: STEVE NELSON P.O. BOX 88050 TUKW ILA ,WA 98138. Dear Permit Holder: Our records indicate that on Jan 19, 1994 one hundred and eighty days will have passed with no inspections ;;having been called for under. Tukwila Building Permit Numberifi,B93..0235' ` . Unless you call for an inspection, or obtain a written extension from the Tukwila Building. Official prior to that date, your above referenced permit will become null and void on Jan 19, 1994. If your project has been completed please call for final. If you are actively working on it please notify our office. If you have any questions or need further information to obtain an extension on your permit please call, the Tukwila Building Divison at 431 -3670. Sincerely, . Denise Millard Permit Coordinator. Department of: Community:Development� o2 * • ••• • we "\.- • -'eeee 02• ".e-51 06 • 8AS/.9 OP BEAR/v(3 H. C. A..$. LEG EA/ 0 PROPERTY CO 6:1? t " v C. 00 I/I/NS POU'r 4 " OowvS,cour ic7 / 74- 1-71Y °Ai:An/7- .577:t EET Lira* STAA'OARO ROPVAW VAL/Cr E3 CA 7C 8A 8 /Al §I /2"X /2" C04 Ulti/v &A A/ /TA Y ‘..9avveR 4.57-40R A/1 DRAI -77- UV-- WA-rER A.4A IN ic2u e Er SOUND PO YVER L/6117, PVA S 1-i /A/G70^1 ,VA 7--uA)Al_ GAS p --4; FAG. jp-7c A/C7 7-H PVC. ST eV. ••• ••■ SS ■, ,•••■••••••/••••••■•■•••••••••••■••, MOIM.maa+ft./NNINaft•••••■••••1 ••••■•■•■■••••••• C.0/./C R GRASS .44,c'oek ic=•,41. / C9 5'74 Z. I_ .6 (rem.,cAt..) 404.7A4. ACCESS SET !41. /RON P/ PE Vv1 PLA877C CA Fa' •t •S`„i% LEGAL DESCRIPTION: That portion of the Southwest Quarter of the Northeast Quarter and Government Lot 5, and Government Lot 6, ALL in Section 35, Township 23 North, Range 4 East, in King County Washington, described as follows: BEGINNING at a monument-at the Northeast corner of the said South- west Quarter of the Northeast Quarter; thence South 07°44'56" West, 470 feet; thence North 87°50'09" West, 628.86 feet; thence South 14°28'47" West, 86.93 feet; thehce.North 75°31'13" West, 30 feet to the TRUE POINT OF BEGINNING; thence South 14°2847" West, 51.57 feet to a point of curve; thence along a curve to the left having a radius of 10159.89 feet through a central angle of 06°47'39" an arc distance of 137.54 feet; thence South 07°41'08" West; 206.95 feet to a point of curve; thence along a curve to the right having a radius of 1,104.55 feet through a central angle of 13°0617" an arc distance of 252.63 feet; thence South 20°47'25" West, 784.34 feet to a point of curve; thence along a curve to the right having a radius of 50 feet through a central angle of 92°41'08" an arc distance of 80.88 feet; thence North 66°31'27" West, 240.80 feet; thence North 17°28'13" East, 1,424.06 feet; thence South 87°50'09" East, 230.35 feet to a point of curve; thence along a curve to the right having a radius of 40 feet through a central angle of 102°18 an arc distance of 71.42 feet to the TRUE POINT OF BEGINNING. • RESERVING an easement for sidewalk and utility purposes over the Northerly 15.00 feet, over the Easterly 15.00 feet and over -he Southwesterly 15.00 feet of the property described above. SEPARATE PERMIT REQUIRED FOR: 0 MHANICAL LECTRICAL 0 PLUMBING 0 GAS PIPING MY OF TUKWILA BUILDING EVASION TOGETHER WITH AND SUBJECT TO an easement for building setback purposes over a 60 foot wide strip of land sukrounding and adjacent to the main building line which is described as follows: BEGINNING-at a monument at the Northeast corner of the Southwest Quarter Of the Northeast Quarter of said Section 35; thence South 07°44'56" West, 470.00 feet; thence Nc,rth ,3750'09" West, 706.22 feet; thenctOputh ; 17°28'13" West, 163.72 feet to the TRUE.POINT OF BEGINNING; thence con-4.' tinuing South 17°28'13" West, 100.00 feet; thence North 72°31'47" West . 20.00 feet; thence South 17°28'13" West, 320,00 feet; thence South 56" 72°31'47" East,20.00 feet; 'thence South 17°28'13" West, 150,.00 feet; thence North 72°31'47" West, 20.00 feet; thence South e1.7°28°/3" West, RESERVING the right of ingress and egress to maintain, install, improve and extend utilities. RESERVING an easement for railroad purposes, and an easement for access road purposes, including, but not-limited to railroad main- track, lead track and spur tracks, as well as for railroad access and storage, and as well as for other vehicle egress and ingress and truck maneuvering over that portion thereof lying Westerly of the Westerly building line produced. RESERVING an.easement for common access purposes, including ingress and egress over the following described portion thereof: BEGINNING at a monument at the Northeast corner of said Southwest ; Quarter of the Northeast Quarter; thence South 07°4456" West, 470.00 feet; thence North 87°50'09" West, 937.93 feet; thence South 17°28'13" West, 31.10 feet to the TRUE POINT OF BEGINNING; thence continuing South 17°28'13" West, 117.05 feet to a point of curvature i• on a line 10 feet Westerly, of the centerline of the railroad lead track; thence going in a Northeasterly direction along a curve to the right having a radius of 393.51 feet; the center of which hears ' South 59°35'08" East, through a central angle of 15°24'35" an arc distance of 105.83 feet; thence North 10'19'51" East, 27.76 feet; thence North 87°50'09" West, 35.00 feet to the TRUE POINT OF BEGINNING. SAINXIMPI•Velo•PPISMPINMPItyrn 580.79 feet; thence South 72°3147" East, 20.00 feet; thence South 1728'13 West, 115.00 feet; thence North 72°3/'47" West, 200.10 feet; thence North 17°28'13" East, 1,165.88 feet; thence North 26°08'56" East, 101.07 feet; thence South 72°31'47" East, 184.85 feet to the TRUE POINT OF BEGINNING. • TOGETHER WITH a.non exclusive easement for .ingress, egressie and • I : utilities purposes, 60 feet in widthethavirt4 30 feet. on eiCh side of the following described centerline. .BEGINNING at a monument at the .Northeast corner of,the-Southsrost Quarter of the Northete4 Quarter of Section 35, Township 23 North, Rg4.4 East,. W.A., in King Ci'unty, Washington; thence Southe07°44.156* West, 470.00 feet; thence North 87°50'09! West, 628:86 feet tosi'a point hereinafter' . designated Poirot 'A'; thence South 14°2847* West, ,13q-.49 feeeto a • point of curve; thence alongra curve to, the left havin4 a radius of . • 1,129.89 feet, through afcentral angle of 06°47'39", an arse distance'of ee 133.98 feet; thence South 07°41'08* West, 206.95. feet to a,poiet of curve; thence along a curve to the right having a radius of 1,134.55 feet through a central angle of 13°06'17, an aro distance of 259.50. feet; thence South 20°4725' Went, 868.11 feet; thence North 66431'27* • West, 321.49 feet to the terminus of this easement centerline, TOGETHER WITH; beginning at Point 'A' described on the above centerline; thence North 87°50'09" West, 30907 feet to the terminus of a centerline having 30 feet of width on each side. .EXCEPT that portion thereof lying within South 180th•Streetr ' • .n, • • P ..• • • . s22::. -'• Sisiote...4sch.pr,„4.34. C c.„4,14a, irtmf-7.41!i4k7". • 4'41%977C .44". $41 1:;.; Ow4powaky &tie ' , *.k• • • 7;4: of; • 4' fv• lag ‘484;*Y SUBJECT, POWEVER, to the right of Owner and Ownerts successors in . title, to relocate said easement within Segalo Business Park on the following terms and conditions: (1) Any such relocation shall perpetuate similar rights of ingress, egress and utilities to a public road; • (2) The width of said relocated thereokshall be similar to that (3) The route of said relocated direct access to a public road; easement'ancl.the'physicalf:surfacing of the initial easement; . - . .. • easemeint shall :afford reasonable . . • • ' • • ; . • . , - : • ; . r. . . rn e . (4). The legal right* of Mortgagee and Mortgagee's successors here-. . under,. 1p and to route of said'relocat+1 easement shall be subs:tan0 tiallir the same as with respect to theroute of :t.hejntitialtease- ..;', ment; • • • . . • . • . • . • . • • • • . . e, (5). Said relocated easement shall be: appropriately-doeuManted by .! . • a supplement to this Assignment containing a.revised legal:deecrip .: thin and shall be insured at the expense of Owneraby a title insuranee -:. company on the same baria as the original relocatable easement. - i (6) The expensea •of such relocetione including.thi consttuctien and surfacing thereof, shall be the sole responsibility of' Olumerl or. • - • Ow.ier's successors.in-eatlei • ' •,1 SUBJECT TO any covenante, conditions, easemen ; encumbrances or • . ,- restrictioes.of record. AILAWASMI15.. flitoilluilipluiliiIIIIIIIIIIIIIIIIIIIIIImplitilwrifir rippiwirpilitiiiiiropripilitliiili lilititiwittilliiistliiy, rtivilliliwililiwidipiliiiiiii iIIIIIIII ...,.._. ,,,L,..,.. - - .,- , 0 to THS INCH 1 2 '/1F'4Y3 4 5 6 7 8 9 10 -,,...,:.,..,.....,,,,,,.,.. I 11 MADE1N GERM"' 12- - , r NOTE: If the' MicrOfilmed document is less clear than this I notice, it is due to the quality of the original document. • • , . ,.• • ATTACHMENT #1 SBP/MAS BUILDING 771 i•- ' '• • ". • *. • /341;1'9'41/ix et›.4... 7.#1/44' /.A./ LEAD e a, , 74C 1: 0' srrE -AREA: 462.1ze. 04 .S.P°. /0. 5/ Ac,rze..s SURVEYORS CERTIFICATE 1 14.e..VEISY Cd.Nrhane 77/A7' THIS Ael•AP C01411:MCMY irtZ/r-ver&SOlarS A 3.UFVV 44.460E L1 Y #4?1 CW CIA 0 del( /WY OAR 41C77 71/ Aar"IIA•so Oir Auou$r, J97'. rfG IS 7`01:PZ 4:1 LAWitille .2 /50.3.1 L.. 1 PO/A/7"A. CITY OF TUKW(LA APPROVED `JUL 1993 0I !IP G SION RECEIVED CITY OF TUKWIL.A JUN 2 4 1993 PERMIT CENTER JUL 2° 1990 .),• ••••••••*. „ SITE ADDRESS: 18)61- 18325 egale Park 0 oe 6e se LZ 9Z GZ 9Z CZ ZZ 0? 61 st et st at et et tit 01, 6 e a,9 G e "'" 0 11111111111111111111111111111111,1111!IIIIWIW1111111,11111111111i11111111111111111111111114141101101[411111116,1111U 111111101.111041,11641111a1111101111111111111111111111111111111111t1,1211,1111j.11.111111111111111LIIIIiIIIIIIIIIIIIIIIIIII1111111111111111iIIIIII • ' • • e. cembv.ese. w. gr. .24"+C770Ai• $ 54: r: 23 1V-- Ai'. 4 WA4„! ...V.4.10 A4 0/..W.1.44W7" Ar . nye Cev7RLivg ehc- . • • 00714 180 wi SrfirEen' A PO Et La C %VTR& Er, S. 073,44 .D'46 4'14; srf ANDovele - .; . . A.7.'"A. SURVEY 13U/I.DING 77/ ' SCALE 1311/SMIESS. ';'PAKL ERiW ETH ER 114110 Pit 2; ft SUM') ilILLIEIft.;!!,48,:, 9400? . 11514U:11120g; • rACHMAN ASSOCIATES."' tws4k. 3 0 Z 9 ervifigto tiPkirtMerli mWMTIM aue6tare...619. blie4Wern filltAir•e> . • • • rat=uarareorintisvziessalymmegytHiiffOltC4IG:AISIMINIMMINarttlOSTAIWMIOWIner" •MINWINI071 IMIINWHOMMO NEW DOCKLEVELORS SEE SHEET 3 ffignalitierUMPAINGIVedingiV~SOVIVIONOMMPrIrM.X.IMMIrtgirleifiterenrftritnr(lrtr7r.Viertgit.rlirYM.W.r.V141,0050.0003M. arbArtiisishPallief.m••■•••••••••••••••••••■••••••••■•■•■monarm*As.*1.4.1100*.r.". DANIEL SMITH, INC. NEW DEMISING WALL SEE SECTION 19) 2 1/2" DEEP LEG METAL TOP TRACK. 8" HDS METAL STUDS, CUT 1 1/2" SHORT FROM TOP TRACK TO ALLOW FOR ROOF DEFLECTION. 5/8" GWB TO BE APPLIED TO .8eiti. SIDES. Otke )4:11/46 \LDIOS:449 \kr G('? gel") DEMISING WALL SECTION .0.. nennWetsPIaO**t, s At..a.w.,rZihart•k*lPiv'Nm...Su'.m.FM.'f•e"olOoWr.I.Au..sc7oS.mW.mm,.tn 0 r.1 .. --rrwm•■••r,cr.it..r.amlto....s..r..a,..en.ytsw..ie.,,..fa.s,...,.erit..enntsclaignmerftxcWpoorPv/roParvwcoolrousasrmOcoIrrmNinnsimavovmaagtfetrwramleirCroiAwir"staN-g1t4o0.tr7.e10s- iMmtAmWteInv.oreg.eylemivorest m .i.Aro.7a.n.i.m...s.•w..,,i,....• vr, .r.e.e...v......, . olorwmn..roe•.c-o•m -•-- . •.....‘.-.. ,x• • .e.,,,,........- • k" ...,r. .. ..•.,••.•• . * ** '•••-r,,•.•■..•"•,/.,.....,.". Vr ro0 a f t,....y...,".••••• ■ 710ata.. .........m....r.m.m,..lb.,..,••••mm 0.0.•*•.•••••••,....••••,,,, ',..i..'' , _ - ■•• .-• , e■ vpan'eRgaw~."..1.9111/MONNOWOW4Ce sselowwporearmoTacrov IROMP.S.A70,41,1002MIIMPWOMN.AMPer WV. • • ....Ay napwr•••frovwc,,,rprwarajagnAprigreetepalarlireffrarMaMigg,r4(4,21r7WWW.VaorefaCrpprigarrnrraffrgrg0Mterrerrbel2WOMPtrglklenWrartteenraDYMIRMICNINOIMPPOTWAVIngiNealitVatVcritnenTAIVIVFMnitinVirrAMIlerr ••••••••• unewaraminusownoossevyzattosastorwasaraommearearnawriarawavtgainaram ------------- ,...-...... •••••-................. ■■••••••••••■••■■•■•■■....M. I L SEE SHEET 2 FOR EXISTING OFFICE PLAN MOi-iAWK CARPET, BUILDING PLAN SCALE '1/16" = 1' -0-4-- NATIONAL DISTRIBUTION NEW DEMISING WALL SEE SECTION CAD FILE: FLRPLAN • • . . -..1•-•toW • -,..„ , • .sdf • .zr?• ;1.• 11111111111111111111111111111111111111111111111)1W1111.11141 11111 II !VI 1 I I I. el 1.1 1 I 1 I 11 I I 11 I I I I #14,144 I It /3 4 5 7 NOTE: If theiiCrofilmed document Is loas clear than this notice, it is due to the quality of the original document. 0 HI ?HS INCH 1 2 06 6Z 8C LZ 9Z GZ 'VZ 'CZ .11111PlUdirtitiPhuld)11064411, .14,01111i1 IllikaIVAMIIIIIIIIIIIIII1111.0111611111111111114111,11111111111;111111111111;11111111i11111111111H1111111111.111111 a 9 L CI Zt • Oi, 6 8 1, 9 G C Z t wh 0 . • ••,!„,.!,. 41,411111111111111111111111111111111111111111111 9 10 11 1414"46ERY'" . CITY OF TUKWILA APPROVED JUL 1993 r-,J1,1 IN" Di SON REvISIONS: 1•111•4.1.4 .M..M.I.MO•••••■■•.**IMM .0•400••■•••■•••• ••••■■•■■■■■■■•••■}11a7WVVI*M1001.10 .131.1001.............11.1•11.11.001..11/1■•■••■■••••101../....••■•••••■••••••• 70•Ia■••••••■••■•••■•■••911 ••■•••■•• 10.•-■•••••••• •••••■■••••••••.. .11.7111.0■•••••• ■••••••••■•111.10....... TMIIIII.MO*NIIIW11.•■••••••••••••••171/411 ■■■•••••■••••.■■■•••* ••••■••*1.• 4326 REGISTERED1 ARC ECT F WA HIN SEGALE BUSINESS PARK TUKWILA, WASHINGTON (203) 575-3200 TIT MOHAWK CARPET BUILDING 771 18255 SEGALE DRIVE »E3" DESIONE0 �Y PROJECT litiiIBEFt 93-771-04 bR,—*TtrITY7-----" DRAM er-- SN Four- , BIT — 11:1S?::= 06•22-93 ORAWittO NUMBER; MEET: 1 CF: 4 „oltValnagaMinsaroegicausatengsamegismosnarerromser, RECEIVED crry OF TUKWILA JUN 2 193 PERMIT CENTER • r. r • I. " " • " • V """"." • " ".• ."‘• •""""*"V " .."*".'".."."1""nrINOTIMMr. 1171.1.Nn, .,1-01 WV." lerie..~114. r AWISI, WNW M, MIAIOGYO, MAW ff PAP AW•.1,1,M*4.1.111.110 • ..... ■•••• ••••• •• 11 , • . .• • •• • • • • • • i ; I • 1 1)7i 1.1 .1 I I /ill - ' •■ • • I 1 , . • ,,, • 1 . , , , , (1:' . I(c) (I I 1 . 0 ..• . • e' ‘,., -, ,°) •1"'cric;,,,,,I.... . I..., • "' - 1 -)- • '- . • • I r. r' 1,11, l I II II .1' 1 • • • • .• • 0., • a 1. • • I , • t . ,, . . , -.1 , • ; i• 1 ; ; ' ' I , r i r . , • , . ' ! 141, 14, '••I l' ' . . I a 1 •1 1 • I . . 1 • 1,1 •• ' • ' • , • ' . • ,' . • • • 1 • ' , 1 . .1 • a 1 a• • 0.••••7••■•0 • • t . .1,11.•••• a • ' • I • •0/ • • 0 • a • • • • • •• • • • • • '1 --t °"11•“H . .. 1-7•":".•':".;..*Il'i.•:.7---7-7-.`1".. • - • " • / • i , • . • 1 ' 1 1 II ', • • f, • , • r ',;1•11 I • I , • • . ■.417....4.• yr.: • I I , • • • h 1 • "• • '• • ' • , • 1 1 • • 1 • 1 • 1:1/`-‘.11-1 c)i-1 •A- I • I • I 1, • ; , r • ! " • , A VS.1 • • • • 1'. " • .• • " • A • • , ' ' ; 1 1. .1 1 ir• • fil".1-:1,1,,.c..1.,..i..,...1).1, \;::: I ,.-: • r.r..1 ;, ,:'i.'',;, :, • i .. ;• L' )i ,‘ : .. 9 z"' '• , ,,. : • , , ?. ..i I 1. T.' :■1111111: • -*. • '1,-, - 1 c-).{.... , 1 1 ' 1 ..‘ri.--I''' 1,•,._ : I..i , I 1 . , 1 011.1 I . , I " i ' • ' 1 I , o ■ ■ ' , • ' • • 1 , • , 1 • L., I • • 1 (.7 . 1 I • • • r . l• • •'1 • • • .1•1 s ; j • , 1. ; • • 1 , 1 • • • • A • • • " .p..• • • A•.. ; •I I' !'',„ • ..1 1 • .1. . . • •I/W4.1•1/1 • '•••F• JasteadAlliZagX4/..f.WrIktaF'.., • • • •41..• "•"'"; •,,t1,1F,1 ;:;"%rt• "icz,c64:- 11111111 1 11'111 11111111111111111 1 .1,11,11.1311 • I.." . • „ • J, ' r 1. I , r 1:11r, 1st ji., , 11 • H L..; tit .. 11 , I ( / I t •• • le • . t P. ' • • / • ' 1 •• . • • tr.; ......... • ; I (RI) I t; I 11 •• ' • \ •• • • I 1 • II\ (..12F . • 14.) " • .1 :1; ;,• c's,' • , • . • I ,11 • , • ' 1 1 1 i . I 1 .. . . . , rl i • ... I 2 tc,•, .1.......) :.....i...1.. ,,..1..::: r.i..(l.....! 1. "1-1:-I!".':-."' :.-..',71-":..:7.".-.':,,,',•••: .71.7.; .7:„. , 1 • • Ir 1 • , • ' ' I-111.1(.11-11. rr, rtrl - .• I .1 '1 2 1/073 4 5 6 7 16 THS INCH NOTE: If the microfiltaeli document .Less clear than this { I • notice, it is due to the quality of the /original document. Oe 6Z ee 9Z 9Z ' ez a-e 0Z . - :• 111111111111111111111111111111111.111.111111111111111.1.11,1141111)WIlk.1),INkl.11,1111.iPppk1/1,1)).:11kl.,1-,4i,,,. LI 91 I 171. EL 1 Li. pi 1111114d411,11,111[1J)11111,11,1111111119pl111111111f11.11,1t1,11 j11.1.11 I 1 1 . , I 11. • 1 1 ' 11 ....,.,..........L.::.1;-:;.1...Ii.1-7•1.1 ( ) 1 11.,...:,..-4....--,-....1-!."71:,:....•-....:,.-.....i.:.•,:.:.....:-.:•..,:.2 1,1,1,t11,111111111111111111111 i 11111111111111111111 10 9 11- MANNURMAM 12, • ‘..14.0.1461,044..1‘411,461.1.110001,401.""Innaill.6"M"."1"4"1"j1416. 62916 111•11C17f!r147j.'"'f'47 I' 71-1•7 '. 7 %"'.17...;1 tre•ir•Pvlevrirrv•-:3., .......-:-,- -1- r,...-. 1:.■14iti.-..;..' nusac...•44-41,3,a4,1i4'.,' ...: . it AL.I.:■;:, ' ' • - ' • 1 ....., ...1144.14'. I . • REVISIONS: •■••••••-* -"•"""'"'"'"'" 1 ••••••••■•■••••••••••••••••••.• ••••••••••■••••••••••••••••°••••• SEGALE E3USINESS PARK , TUKWILA, WASHINGTON (2oe) 5Th-3200 WM. ZZ"4:21a:7117 141M717,71,7,77,172,Z7,7.77.7"- TIII.E.: MOHAWK CAPPFT BUILDING 771 18255 SEGALE DRIVE " B" DESIGIIED BY! Oftni BY: CI ECKED - --- SCALE: 1,/8" -= 1,7117.517=.17.4.. DRAWN° KAMER: PRO,ECT WIDER: 7 7 OR A YIN BY: I StSVE DATE: D Alf:: ••••••••••••■•••-• • "..Trr47:=1..:7717,77-7 I 1' I 1' 11 11 1 11. •-•••.,..14.••■•****4•••aorrefflr.t StIF.E11 2 oF: 3 drrr.,SXM.rrA.rNoPVVMDP.I......W.KOPI.1•0.0IrP•nPfr,V,,IPMNtlarlorhIIF,MrVlrfr:aaamrro3gYraCesWorIVS.,AIWNa.rrr.rmrrrrPtlsaro~r•alad. icrommagsarwormilrarrrrnmetvr-.----14 r • r f." - • '" •.0 1,•„•%. RECEIVED CITY OF TUKWILA RN 2 4 1993 PERMIT CENTER vgavienraaNrovortrrwsroovvvivroceiriv t N71Va! aion1 1wezr Kcera4eorma"` vsor minwommoiEY. rft, ttvwsPeii:rlOfoleYisnsextorarrimresalnKr7lfi omna omstvrog7ommtlyrt rthrwram1f{'RrT' Ivers.Ltdixir r9•.p:rimp 'virrn1at/•RroT.•N•rrtr;,, v.- y9“- tweev. ,...•w!3• :e rtt? !.4farterrs'IiRILf+'3Ltmatria; .M1egurtimIcr Ytuargef frArrvxi'S'7"33111SA: