HomeMy WebLinkAboutPermit B93-0360 - PAYCHEX - PARTITIONS, DOOR AND CABINETSA
•
1.1.. •
dw
PAlcA0(
F713 (3)63to
Ciiy of Takwill:
Community Development / Public Works • 6300 Southcenter Boulevard, Suite 100 • Tukwila, Washington 98188
(206) 431 -3670
BUILDING PERMIT
Permit No: 893 -0360
Type,: 8 -BUILD
Category: ACOM
Address: 565 ANDOVER PK W
Location:
Parcel #: 262304 -9075
Zoning:
Type Const:. V -N
Gas/Elec:
Wetlands:
Water: N/A
Contractor License No.: DODSOPI101JB
TENANT PAYCHEX
565 ANDOVER PK W, ,_TUY:W-I1.A` ::WA: "`98.1,:8
OWNER TCW REALTY HOLDING,:' :CO' `
400 S HOPE S,T, OS` ANGELAS CA 90071
CONTACT GREG BYLER t Phone: 206 859 -9804
400 SOUTH, .HOPE STREET," LOS - ANGELES, C 90071
CONTRACTOR DODSON , PATTISON INC f;'' Phone`:; °206 361 -2989
12304 ,,31ST AVENUE °'NE ,.:SEATTLE SEATTLE,-WA-98125,
Status: ISSUED
Issued: 09/29/1993
Expires: 03/28/1994
Type of Occupancy: OFFICE
Slopes: N
Sewer: N/A
************* �k*****.**t*'*'****'******** x'*,*.*:********* * * * * * *Ykk * * * * * *. * *.:k* * * * * * * * **
r .
Permit Description:
INSTALL PARTITIONS, ONE<:'INTER,I.OR DOOR, AND INSTALL
CABIINETS REMOVE PART- -PTION WALL
Units: 00
Buildings 001
Fire Prb,tection SPRI:NKLERED
UBC Edi;tion:;, 19 1 `k
SETBACKS
Back:.
Right:
•
P 'Valuation: 10,000,00
To'ta1 Permit Fee z 197' 55
i * *•k * * **.*ik * *i* Ik******` k*.**'* k***** ****** k4'** k**, p* * * * * *** * * * * **** **•k **
Permit C n.ter }uthbri zed Signature
I hereby oe ,ti fy, ,that:•:.I have read and/ :examin,ed ,this; permit' -'an,d know the
same to be*�,arue'and cdrrect. All prgvisionis of law` and ordinances'
governing t,) is work will`.; be complied'' with, ;whethq'r `specified herein or not
The granting Yof \thip,a
s: rrmit` does not presume jto. give authority ;to violate
or cancel the 'pr4Prtvisidn.s of anj/ ''o:t.het;:,,tste,te °�'or local »aws regulating
construction or�,,,th`e,,,:performance of work. I, am authorized to'•`sign for and
obtain this build ,,f verwit.
51 gnature
Print •Narne . E 7 G ` ��G dr.X ....r 'ri t <'! `CIQ G . L 't14 iii/
This permit shall become null and void if the work is not commenced within
180' days from the date of issuance, or if the work is suspended or
abandoned .for a period of 180 days from the last inspection.
CITY OF TUKWIL,A�
Department of Cot..,nunity Development — Permit Cent,
6300 Southcenter Boulevard - #100, Tukwila, WA 98188
(206) 431 -3670
Building Permit Application Tracking
PLAN CHECK
NUMBER
695-03 (D o
PROJECT NAME
SITE ADDRESS
()40
E5 Nndov.ev PK W
SUITE NO.
INSTRUCTIONS TO STAFF
• Contacts with applicants or requests for information should be summarized in writing by staff so
that the status of the project may be ascertained at any time.
• Plan corrections shall be completed and approved prior to sending to the next department.
• Any conditions or requirements for the permit shall be noted in the Sierra system or summarized
concisely in the form of a formal letter or memo, which will be attached to the permit.
• Please fill out your section of the tracking chart completely. Where information requested is not
applicable, so note by using "N /A ", date and initial.
DEPARTMENTAL REVIEW
"X" in box indicates which departments need to review the project.
DEPARTMENTr r
TE
BUILDING -
initial review
.4 FIRE
APPROVED'
• 2•q3
ROUTED)
QUIREMEN
MMEN
CONSULTANT: Date Sent -
Date Approved -
Cita
INIT:
FIRE PROTECTION: ;1 Sprinklers • Detectors • N/A
FIRE DEPT. LETTER DA D: z� INSPECTOR:
(2-
O PLANNING
Aix
3/21M
INIT: j
ZONING:
REFERENCE FILE NOS.:
IBAR/LAND USE CONDITIONS? L)Yes [-1 No
MINIMUM SETBACKS: N-
s-
E-
O PUBLIC
WORKS
UTILITY PERMITS REQUIRED? U Yes [ 3 N
INIT:
PUBLIC WORKS LETTER DATED:
O OTHER
y BUILDING -
final review
BUILDING
OFFICIAL
REVIEW COMPLETED
TYPE OF CONSTRUCTION:
CERT. OF OCCUPANCY?
°Yes XNo
UBC EDITION (year):
Ict 'iI
AMOUNT
OWING:
CONTACTEDYQ-
DATE NOTIFIED
_ CO
BYt.) __cgs
s
2nd NOTIFICATION
BY:
(init.)
3RD NOTIFICATION
BY:
(init.)
ov08 /93
CITY OF TUKWILA
Department of Community Development - Building Division
6300 Southcenter Boulevard, Tukwila WA 98188
(206) 431 -3670
BUILDINJ PERMIT
APPLICATION
PLAN CHECK
NUMBER
<:DESCRIP.TION
>:AMOUNT,;;
RCPT:::#
DATE
BUILDING PERMIT FEE?<
BUILDING SURCHARGE >?:
OTHER:`':
SITE ADDRESS SUITE #
5(56' Andover Park West
VALUE OF CONSTRUCTION - $
$10,000.00
'PROJECT NAME/TENANT
Southcenter Corporate Square- Paychex T. I.
ASSESSOR ACCOUNT #
z6,2304 _-. g075 -00
TYPE OF • New Building • Addition !a Tenant Improvement (commercial) • Demolition (building)
WORK: 0 Rack Storage 0 Reroof 0 Remodel (residential) 0 Other
DESCRIBE WORK TO BE DONE:
Install Approx. 36 lin. Ft. Clg. Ht. partition, 1 interior door, and remove approx.
24 ft. interior partition wall. Install approx. 10 lin. ft.cabinets.
BUILDING USE (office, warehouse, etc.)
Office /B -2
NATURE OF BUSINESS:
WILL THERE BE A CHANGE IN USE? ax No 0 Yes If Yes, new building requirements may need to be met. Please explain:
SQUARE FOOTAGE - Building: Tenant Space: Area of Construction: + 700 s. f.
WILL THERE BE STORAGE OR USE OF FLAMMABLE, COMBUSTIBLE OR HAZARDOUS MATERIALS IN THE BUILDING?
cax No 0 Yes IFYES, EXPLAIN:
PROPERTY OWNER TCW Realty Advisors
PHONE 213
-683 -4200
ZIP 90071
ADDRESS 400 S. Hope St. , Los Angles, CA
CONTRACTOR T) -��-- C •
to be selected � ..
PHONE
ZIP
ADDRESS
WA. ST. CONTRACTOR'S LICENSE #
EXP. DATE
ARCHITECT LPN Architects Attn: Terry Johnson
PHONE 206- 583 -8030
ADDRESS 1127 Pine St. Ste. 300, Seattle, WA
ZIP 98101
:. I . HEREBY: :.CERTIFY:::THAT : : :I !I1AVE R
BE: TRUE :AAND i'CORRECT' .AND`i .A
BUILDING OWNER
OR
AUTHORIZED
AGENT ADDRESS
XAMINED :THIS>APP.L:ICATIQN :AND
E� *APPLY FOR THIS;PERMIT...
e Street, Ste. 300
DATE
PHONE 206- 583 -8030
CITY/ZIP WA 98101
CONTACT PERSON LPN Architects, •�����••�•�•— •�• / , / /ell- PHONE •-28
APPLICATION SUBMITTAL In order to ensure that your application is accepted for plan review, please make sure to fill out the
application completely and follow the plan submittal checklist on the reverse side of this form. Handouts are available at
the Building counter which provide more detailed information on application and plan submittal requirements.
Application and plans must be complete in order to be accepted for plan review.
VALUATION OF CONSTRUCTION Valuation for new construction and additions are calculated by the Department of
Community Development prior to application submittal. Contact the Permit Coordinator at 431 -3670 prior to submitting
application. In all cases, a valuation amount should be entered by the applicant. This figure will be reviewed and is
subject to possible revision by the Building Division to comply with current fee schedules.
BUILDING OWNER / AUTHORIZED AGENT If the applicant is other than the owner, registered architect/engineer, or contractor
licensed by the State of Washington, a notarized letter from the property owner authorizing the agent to submit this
permit application and obtain the permit will be required as part of this submittal.
EXPIRATION OF PLAN REVIEW Applications for which no permit is issued within 180 days following the date of application shall
expire by limitations. The building official may extend the time for action by the applicant for a period not exceeding 180
days upon written request by the applicant as defined In Section 304(d) of the Uniform Building Code (current edition).
No application shall be extended more than once.
If you have any questions about our process or plan submittal requirements, please
contact the Department of Community Development Building Division at 431 -3670.
DATE APPLICATION ACCEPTED
c al -q3
DATE APPLICATION EXPIRES
3-at -aU
03/1681
COMMERCIAL-
SUBMITTAL CHECKLIST
• • .. „........„ . .
fl] Complotod ...........................................
.......g permit aPplicationjOne:.for:eaCti
. • .........
. „ •
:, Two sets (2) :Of the:following:.
Spectfications
: • :••:..:
Structural Calculations stamped by'a:Wathirigtori:State:11ConSed
• •
. .
Soils re0Ort:staMPed.bk.a. Washington:StaterliCeniiid enginoor
. • • • . • •',
" • :••••••:':
Topographical survey . . . .
• • '.•
. ..„ .
r1 :Energy, calctilation.s stamped by aWashirigtor,State.:fiCensed.,;.:::::„:.:,:.:
• engineer. cr..architect . .
• • • :. • .. . ...
Legal description .. .
Working:draWingai.'stamOad by a Washington State licensed
• . ............
..•.. .• •... .• .....
•••••
Site plan
Architectural drawings
Struetural drawings
Mechanical drawings
EIevaons
• :
••
•
.....
.....................................
Six (6) Seta of civil drawings
submittal • ..„.
• .. .
RACK .• •
• • • • .• •
Completed et/I:ding:permit:application
• • :
„.„..
: ..
Two (2) sets of plans ,: which include
Building floor plan showing :s.., I. •
• Entire space where racks Will be located •
Exit doors
• Dimensions of all aisles . . •
Tenant space floor plan showing rack storage layout, aisles
exits,
NOTE: Include dimensions of racks (height, width and length), aisles
and exit ways on plan. •. • ..• • • • • ••
Structural calculations stamped by a Washington State licensed
engineer (rack storage 8 and over). : •
RESIDENTIAL
NEW SINGLE-FAMILY DWELLINGS/ADDMONS
1 I
e
• Tenant location
• Usa o( adjacent (common wail) tanant
Floor plan of proposed tonant ...
patterns .......................................................... .. .
•
. i• :•.:::. ::: a:::••p. • . . P.. 1 /6S0t. r. h toi. ci..te.4Yt.
a.i„.:tc.- r. iI..:c: •
.•••••::•::.•:„.•..::::•,...,:•:•.•.. • •• . • • • ••
.,,,:.::„*::..:.:..::,:„:::.:„::.•„•:••. .
, •.
:•.. •
••,.. .....:.:. COMMERCIALTENANT:IMPROYEMEN
Completed building ,permit•application
• Location of tenant space
•••••••:••••••-
U, s.
construction and method
attachmertt for floor and ceding
. • • „ . .
. . . • • • • .• . • • . .
. . • . • . . .
. , . . . . .
. , .
1 1:Q0 pt building permlt ppl oneicir.baah'...atitietUre
[J Assessor Accoun( Nunibor
r1 Narrative descnbing exisng roof material being iemovad,
matenal being installed
NOTE A ‘.‘ cortf,cation Jotter is requirod pnor to final inspoction and
. .
0!! 0! tho porrnit
..:.• •
Asse •
Two (2) sots 01 plans which inolude
LSite . •
... . ..
Detalls • antenna/satellite method of
t
• '..Washington • •
RESIDENTIAL REMODELS
Completed building permit application (one for structure)
Legal description : •
AsSossor. Account Number .. . .
• . :
—1 Two sets (2) Of working drawings ; which ineludo
(on closesi
Foundation plan
• • Floor pian wld#i and Iongi'h o/ access)
Rool plan
• •„.:. • :......,••
Building elevations (all
'Building
•
Structural • framing plans .:••••.
_j Washington :Energy ...Code data
ri• Completed
1 I
' • ••-, •—•• ,•• •• .
Completed building permit appticahon (one for each structura)
. .
Assessor Account ............................................... •
Two (2) sots af working drawings which inolude
Site plan
. .
. .......... ..
Roof plan .... . • •
• Building elovations (all views)
• Building cross sootion
•
NOTE 1! any PrOi4dii;iitilitji Permit:
and plans must bo submitted . '
• • • ••• • • . . • . • • •
„. .
Completed bUlidingPermit
. ...„ • ..• • ....• „„ ............. ••••.• • •.....••• ••:•••
Six sots of sito plans 'showing :utilities 'Ll.ASsessdr:ACCourt
..„ ...„...........,....,, „
NOTE: Building sito plan and utility site plan May be combined.: See .
utility permit application and checklist for specific submittal requirements..:
Additional topographical and soils information may be required if unique
site conditions ................ ..
Narrative describing existing roof,:rnateral being remov9d, and
material being •
•
NOTE :.A certification letter is required prior to final inspection and
off of th •
:,,_...:44..77•:7.77
EKED AS PRY/13ED BY LAW AS A
D
att
0
,;
• kJ
1
u u:
• o
0.4 •
473 P.4
4N. Mr.
•
u
z
0
V ILI
IC in
%trVI' .J
V .•4 IA 4 F••
..0
.w •`�.� �aartr.
. 4
a
6q3 -030
P0.,y ch-e�
RECEIVED
CITY OF TUKWILA
SEP 2 8 1993
PERMIT. CENTER
h*****h* * *****lt* *****k•k*h**** * k*** k***** ****k•kh*•*************** •
CITY OF TUKWIL.A,' WA TRANSMIT
. h****•* k******************• kh*• k**** ****** * *hk*h ******************k
TRANSMIT Number: 93001335 Amount 197 »55 09/21/93;.11 ).2;
Permit No . B930360 Type. B- -BUILD 1UILDIN6 PLRMTT
Parcel NO:' 26230.4 -9075
Si,to..Addre.se: 565 .ANDOVER. PK W 09/21/93
Payment Method: CHECK Notation: 3SH PROPERTIES Irtit: SLR
k .k.; k*** 444, h**** hh** sk• khhkhhh* hh• k*** hhhh .hkha *hhk *hhhhhhhikhkhkh **h•k
Account Code
000/322.100
000/345.830
000/386.904
De.sCripti.on
BUILDING - NONRES
PLAN CHECK -• NONRES
STATE BUILDING SURCHARGE
Total (This Payment):
. Total Fees:
Total Ail Payments:
Balance:
197.55
197.55
»00
Paid
117.00
7,.05
4.50.
197.55
GENERA 117.00
GENERA 76.05
GENERA 4.50
TOTAL 197.55
CHECK 197.55
CHANGE 0,00,
4591A000 14 :29
CITY OF TUKWILA
Address: 565 ANDOVER PK W
Tenant: PAYCHEX Status: ISSUED
Type: 8-BUILD Applied: 09/21/1993
Parcel #: 262304-9075 Issued: 09/29/1993
************************k***********************k**********************A*k*
Permit No: 893-0360
Permit Conditions: . .
1. No changes will ba.' made..totie:::40Vaiiik"Uill'es.s.„ approved by the
Architect and the : To k414B wiltn iii Division. , , •
2. Electrical permit„Atal'f'be pbtainedy,througii'iWe4/ashington
State D i v i s i on46t-.L.4)or,. and, Indust r.0'.0s and 4 a l l 'alaCtr i ca 1.
work • w i l l b eAffeifact aXi• 13!;$ that ageii61 (2487,6639 ) . ' ''''.\•:Wi•:.,
3. Al 1 mechan)sa1/Wor:le4h,a111 b'e under separate j'.).,,ermit 6040
. the C i ty Of .:fu k IV ta,.% ' .,„4,,',.:, '--':' ''', 'z' c ‘0 ,,,.. ,,,,, ., k,- ,...,,,,..'„,:• \i,:,::-,,, ,!::‘,,
wo- .fr , A
4. All perm.,,f,f,t4-. ..il)spact i on., r'e cords ,: and • approved plans -- shall be
ma i n t a 1,4d a VJa*-4„1, atria , a t the 'IO:bl i,s'Jlit,e prior ii),,,t hd;:: start of
any coAtiruct i oiv: These t,tificuMents ?are to be malntal_nad
a v a i 1 a§/lle Ant i 1 final i nO‘e-rdti,i on approval Is granted.
5. Par t Yitli6n4.i,,(41 1 s attached r to ceiling gri d must be laterally
b r a c a l l ifoo..i.), 61- eight (0, f e e t 1,6--.length.
,--
6, All 1:Cio'nsiruOtion to ba-done. . ,..1W conforMance with approVed-If' .
'c-,-,-, • , - ej I .,,
p 1 a ';`1 andtk,re quj rementi.! 1--cfthpi On i foin),189J,-141:ng Code (1991 .'
Ed i 1.on) as . amended - by -thel.,W;ashilratop Statal,Bui 1 d i ng ''•code...",
... -. ,
Uniform Mechanical Cade (1991 Eittilfcin ) and Washington State
1. 1
En ally , Code .( 1991 Second '141 on) .N,,,
7. Va 111.1i ty :of . Permit': The issuance of a or approval of
p 1 aali;i, specifications and icchtptnatlons, shall not be con-
strue fi
: to be perioit!„40"r.ror an %,,a pp r.:`;.9‘41`..„,,of,, any violation ,
of . any of 31,,t' e ryrovi s i ons of tll i s% cOde ,fdr lof.--alify other ‘,....„,...,0
t i . ) s,
ord 1 . flp cepx ' the J ur 1 s d i c t on ... A&;:ii`fr,m,i't _pi' es Um i ngo,"'to ,1,9,1V6
as u t h 1\: ". i l ,1t\
y4,oV Nv . i .6'J a t e or cancel . t iI: pr:, c( . ili i • 'l `po.,, risf1-. d,3 f this • 4kco
tri
‘ h
ha 11 I 493 ia
. qk
. .•‘1 1 " \ ... '•0 0
i ' , • •1 ''
."'X.'•;at, . ig" ,
. s
9 44 • V , ''Itx+, \ .,,skJ, 4'-' ' .,, '
\?;:\ ' '". ,?, ' t't ,,,,,,-:-' • '.410' A j,
' • ,';'% t, .• :,-...,,, e.:,' ,.. .6, ,,,, ,A,, it ,,, .
et "' /Mr/ •
q t, , I. V •
c'e
4' •
„
,O.T,e.Al•Vc;"
•It 114'
PA'r' '41
411•1111 IIIMMINNI■1•11.
City of Tukwila
FIRE DEPARTMENT
444 Andover Park East
Tukwila, Washington 98188 -7661
(206) 575 -4404
OMNI
John W. Rants, Mayor
September 23, 1993
Fire Department Review
Control #B93 -0360
(512)
Re: Paychex - 565 Andover Park West
Dear. Sir:
The attached set of building plans have been reviewed by
The Fire Prevention Bureau and are acceptable with the
following concerns:
1. Exit doors shall be openable from the inside without
the use of a key or any special knowledge or effort. Exit
doors shall not be locked, chained, bolted, barred, latched
or otherwise rendered unusable. All locking devices shall
be of an approved type. (UFC 12.106(c))
Dead bolts are not allowed on auxiliary exit doors
unless the dead bolt is automatically retracted when
the door handle is engaged from inside the tenant
space.
Exit hardware and marking shall meet the requirements
of the Uniform Fire Code. (UFC 12.106 - 12.111)
2. All new sprinkler systems and all modifications to
existing sprinkler systems shall have fire department
review and approval of drawings prior to installation or
modification. New sprinkler systems and all modifications
to sprinkler systems involving more than 50 heads shall
have the written approval of the.W.S.R.B., Factory Mutual,
Industrial Risk Insurers, Kemper or any other
representati.ue designated and /or recognized by The City of
Tukwila, prior to submittal to the Tukwila Fire Prevention
Bureau. No sprinkler work shall commence without approved
drawings. (City Ordinance #1646)
Contact The Tukwila File Prevention Bureau to witness
all required inspections and tests. (UFC 10.503) (City
*ILA
City cri Tukwila
FIRE DEPARTMENT
444 Andover Park East
Tukwila, Washington 98188 -7661
(206) 575 -4404
Page number 2
Ordinance #1646)
6
John W. Rants, Mayor
3. All electrical work and equipment shall conform
strictly to the standards of The National Electrical Code.
(NFPA '70)
4. Required fire resistive construction, including
occupancy separations, area separation walls, exterior
walls due to location on property, fire resistive
requirements based, on type of construction, draft stop',
partitions and roof coverings shall be maintained as
specified in the Building Code and Fire Code and shall be
properly repaired, restored or replaced when damaged,
altered, breached, penetrated, removed or improperly
installed. (UFC 10.601)
This review limited to speculative tenant space only
special fire permits may be necessary depending on
detailed description of intended use.
Any overlooked hazardous condition and /or violation of the
adopted Fire or Building Codes does not imply approval of
such condition or violation,
Yours truly,
K5ez •
The Tukwila Fire.Preven ion Bureau
City of Tukwila
Fire Department
Project Name
John W. Rants, Mayor
TUKWILA FIRE DEPARTMENT
FINAL APPROVAL FORM
Address S G' i"" ,4 h cl puev -/: LtJ
Retain current inspection schedule
Needs shift inspection
Thomas P. Keefe, Fire Chief
Permit No.� Ls -0 3‘0
Suite # aalb
Approved without correction notice
Approved with correction notice issued
Sprinklers:
Fire Alarm:
Hood & Duct:
Halon:.
Monitor:
Pre-Fire:
Permits:
Authorized Si. ature Date
FINALAPP.FRM T.F.D. Form F.P. 85
Headquarters Station: 444 Andover Park East • Tukwila, Washington 98188 a Phone: (206) 5754404 • Fay (206) 575.4439
INSPECTION RECORD
Retain a copy with permit
. CITY OF TUKWILA BUILDING DIVISION
6300 Southcenter Blvd., #100, Tukwila, WA 98188
PERMIT NO.
(206) 431 -3670
oved per applicable codes.
❑ Corrections required prior to approval.
Ali di
for��,It'�I L/.!/ //L �:� : fig%
"REINSPECTION FE REQUIRED. Prior to reinspection, fee must be paid at
6300 Southcenter Blvd., Suite 100. CaII to schedule reinspection.
1011
Date anted*
— C - 9 P.m.
r4rEZMainnalla1.-""...
Sp: • . nstnxt ono:
Requester
)
V
AM
oved per applicable codes.
❑ Corrections required prior to approval.
Ali di
for��,It'�I L/.!/ //L �:� : fig%
"REINSPECTION FE REQUIRED. Prior to reinspection, fee must be paid at
6300 Southcenter Blvd., Suite 100. CaII to schedule reinspection.
INz SPECTION RECORD
Retain a copy with permit
CITY OF TUKWILA BUILDING DIVISION
6300 Southcenter Blvd., #100, Tukwila,, WA 98188
-Project fy
a ( { "..P
Type of Inspection: r t'"—
,c/i�t �i .�
r ,ss. in1�, P, , , :
Date Called: / / — /ty. c73
,
$pedal nstructlons:
Date Wanted
' /(9 .. f
_/
am. p.m.
Requester,
,t / J n /�
l��K..
NtioneNa:
/� l
Kb
0 Approved per applicable codes.
Corrections required prior to approval.
COMMENTS:
WA-vt— BrzAc•,.nc; ,AaP vs-0.
ry r] Pr w Al— CA NI f ; j J try h1in L-
r. 1. c • 9%.4-v11
•
I Inspector:
\e: it(i�,�i�
❑ $30.00 REINSPECTION FEE REQUIRED. Prior to reinspection, fee must be paid at
6300 Southcenter Blvd., Suite 100. Call to schedule reinspection.
(� INSPECTION RECORD
Retain a copy with permit
CITY OF TUKWILA BUILDING DIVISION
6300 Southcenter Blvd., #100, Tukwila, WA 98188
(206) 431 -3670
Project: #a., C L `
F�tA
W type of Inspec h�, (, ,6
rasa: S (9 S
A . P,
.:,e min.
aenEtnidlons:
Date Wanted:
1 t 3/q. . .
Requester.
Phone No.:
1' Approved per applicable codes.
COM ENTS:
❑ Corrections required prior to approval.
I) C Vlr`'7i-nn"71
r i3 S c-e
fnsaector:
-
❑ $30.00 REINSPECTION FEE REQUIRED. Prior to reinspection, fee
6300 Southcenter Blvd., Suite 100. Call to schedule reinspection.
r
3rC3
ust be paid at
"Date:
INSPECTION RECORD 0
Retain a copy with permit
CITY OF TUKWILA BUILDING DIVISION
6300 Southcenter Blvd., #100, Tukwila, WA 98188
PERMIT NO.
(206) 431 -3670
•rZiP
ypeo ns.:• . n
I!„ ;,.�
fate Called:
(J ..._ ,..
��~� . SinJd •
le,'
Date "ant = � •
Requester.
4.1 I
,. .
Approved per applicable codes. D` Corr6tions required prior to approval.
113f_ 34.7g
b-4.eAt•,
O $30.00 REINSPECT! • N FEE REQUIRED. Prior to reinspection, fee must be paid at
6300 Southcenter Blvd., Suite 100. Call to schedule relnspection.
No,:
Date:
ee
I
r'4
t•
T� EAST
WALL
SOUTH
CE
WEST � CEILING
MAT. _ilN51 I MAT. FIIIISH
\ . t 4 Oral + l: ,40∎7167N.1 ow. ex 4er r:Iye""' gke..
EXISTING v' X 4° LIGHT FIXTURE
PROPOSED 2' X 4' LIGHT FIXTURE
El EXISTING 2° X 2 LIGHT FIXTURE
PROPOSED 2' X 2' LIGHT FIXTURE
EXIST. FIXTURE TO BE RELOCATED
q RL:CESSED DOWNLIGHT
S-4A,
51-0"x. 914:
TENANT DEMISING WALL
1 HR RATED W/
SOUND BATT INSULATION
STUD & DRYWALL W/
SOUND 3ATT INSULATION
SLOT DIFFUSER
CEILING DIFFUSER
JUNCTION BOX ABOVE CEILING
DUPLEX OUTLET + 12"
FLOOR MOUNTED OUTLET
DUPLEX OUTLET + 42"
AEC T, ACOUSTICAL CEILING Tv
A.F.F. ABOW FINISHER FLOOR
ALUM, ALUMINUM
ASPH, ASPHALT
MOD. ANODIZED
BM, BEAI4
BD, BOARD
BLDG. BUILDING
BU('G. BI.00<ING .
"BIG. CEIU G
IL CENTERLINE . .
COL COLUMN
CONC. CONCRETE
CONST. CONSTRUCTION
CONT. CONTINIOU$
b/F DRINKING FOUNTIAN
b11.. DETAIL
DIA. DIAMETER
DIM. DIMENSION
D.S. DOWNSPOUT
DR. DOOR
DWG. DRAWING
E.F.T. EXT.INSULATING PANEL
ELEC. ELECTRIC
ELEV. ELEVATION
ENG, ENGINEER
EQ. EQUAL
EQUIP. EQUIPMENT
EXIST. EXISTING
EXP. EXPANSION
EXT. EXTERIOR
r -
1
NEW TENANT WALL
AREA SEPERATION WALL
Ma•��$. r+" .�-GN -I-, 4
Lit) r.:r1 fc'f,;Ci�.4►. =�
`G•
FLOOR MOUNTED TELEPHONE
THERMOSTAT + 60"
LIGHT TOGGLE SWITCH + 42"
3-WAY LIGHT TOGGLE SWICH
TYP. SPACING FOR WALL OUTLETS
EXISTING TO REMAIN
F.D. FLOOR DRAIN
Fr FEET
F.F.
FIN. FINISH
F1R. FLOOR
FIG. FOOTING
FND. FOUNDATION
F.O.G. FACE OF CONCRETE
F.O.F. FACE OF FRAMING
GA, GAUGE
GL. GLASS
G.L.B. GLU- LAMINATED BEAM
GYP. GYPSUM
G.W.B. GYPSUM WALL BOARD
HDWR. HARDWARE
HGT. HE1GIiT
FRCP. HANDICAP
HR. HOUR
HORIZ. HORIZONTAL
INSUL INSULATE (INSULATION)
INT. INTERIOR
JOINT
JOIST
LAVATORY
sFR, , MANUFACTURER . • '
MAIL. MATERIAL.'
MAX. MAXIMUM
MECH. MEcHANIGAS.
MIL. METAL
MIN. MINIMUM
MIX MIXTURE
NOT TO SCALE
NO. (0 NUMBER
OFF. OFFICE
0.0, ON CENTER
OPNG, OPENING
PNL. PANEL
PTN. PARTITION
PL. PLATE
PL.LAM. PLASTIC LAMINATE
PLYWD. PLYWOOD
P.L. PROPERTY LINE
P &P PATCH &PAINT
R.B. RUBBER BASE
REC. RECEPTION
RECP. RECEPTACLE
REINF, REINFORCING
R.Q. ROOF DRAIN
RM. ROOM
SDG. SIDING
SPEC. SPECIFICATION
STD. STANDARD
STL STEEL
STRUCT. STRUCTURAL
S & V STAIN iS VARNI$H
TELE. TELEPHONE
TEMP. TEMPERED
T. TOILET
T.O.P. TOP OF PARAPET
TYP. TYPICAL .
T.I. TENANT IMPROVEMENT
T.W.C. TACKABLE WALL COVERING
U.O.N. UNLESS OTHERWISE NOTED
V.C.T. VINYL COMPOSITION 'TILE
v.W.c. VINYL WALL COVERING
VENT. VENTILATE
VERT, VERTICAL
W. C, WATER CLOSET
W.COV. WALL COVERING
W.H. WATER HEATER
W.R. WATER RESISTANT
WD. WOOD
Iffit
- - -- - e - he \.10U4ai A'.e.
-2 G%
T.C.W. REALTY ADVISORS
TENANT DOOR HEAD TYP.
T „
NANT DEMISING WALL
1 RN rp.-to C:JiI
eteftscoOsNrIZel.:( TYP;
CW4 Fi•eib...f`4 it ;err
4D142," MaTA.L 'r^1
!x14: 4:0 m
.•'� 11
1 4 '% c FAAMS.
14 4.14 4.
(T") dU /.4 -I- eKI
1. All materials and workmanship sha11 conform to the 1991
Uniform Building, Mechanical and Electrical Codas or most
recently adopted edition.
2. Typical detatla 0101 apply where no specific details are
given.
3. The contractor shall verify all dia4ensioes, elevations,
ani existing conditions prior to construction.
4. All dimensions are to teeke precedence over scale shown on
plans, elevations, sections and details.
5. All exit doors to be operable from inside building
without keys or special knowledge.
6. Work related to tenant improvement and required
coordination to shell construction shall-be determined by
'the General Contractor for bidding and contractual
agreement.
7, Walls are to by flrestopeeNd per UBC Suction 2514(f).
8. Fire extinguishers shall be provided per NF'PA #1D, Hose
stations to he located per local agency requirements.
9. Doors not numbered are existing doors and are to remain.
1D. All interior ewallcovering materials sh311 be fire
resistive or shall be treated to be fire resistive, se as
to result in a flame spread rating of at least Class III
for general areas, Class II for exitways, and Class I for
enclosed' vertical exltways. Deliver certificate to the •
local fire department.
11. Install sprinklers according to drawings approved by City
of Tukwila Fire Marshall.
12. All equals to be submitted to 'architect for review prior
to construction.
13. Bid design work to be reviewed by architect prior to
construction,
TNAt PORTION Or ?NE IAS3 AALr or THE NORTHEAST QUANTLY Or THE
SoutoCAST QUARTER Or SECTION c:., TOWN3NIP 23 NOa?H, RANor 4 EAST,
Y.N., IN KING COUNTY. WASHINGTON DASCRI$RD AS FOLLOWS:
B EGINNING AT TEE NORTHEAST CORNER Or SAID CAS' HALO WHICH IS NORTH
8$403•42' WEST ALOon THE MONTH LIdt Or SAID SOUTHEAST QUARTER A
DISTANCE 07 1.119.34 FRET 'EON TOE NORTHEAST COINED Or SAID SOUTHEAST
• QUARTER; THLNCs sOUTII 01047.2!" LEES? ALONG VAC EASE LINE Or SAID LEAST
N air A DISTANCE 0! 1.)22.3$ FEET TO TNT $GUTRTA$T CORNED ?HEMP;
THENCE NORtN 0705540/0 HUT AL0116 Tel ROUTE !!Mt Or SAID ':Its? NAL? A
DISTANCE 'Of 63005 PICT TO TIE MAST Li,E Or TNC EaRT 65',34 PM' or
SAID Iii ST ESL*'; ?NEMCC %PORTN 014,47'l9" FAST ALOIta SAID NEST LINE A
DISTANCE Or 1,320.30 Ytt7 TO TNI MORTI LIRE Or SAID Ells? HALT% TMIECE
s0UTN 00.03.42" a :AST ALONG SAID MOMTM LIX! A DISTANCE OY 659.34 'ter
TO THE POINT Or BEGINNING;
EXCEPT THE BAST 30 PERT TBENEOF YOB ROAD;
ALSO EXCEPT 9311.11O4D Tl r. &GA AS RESERVED SY UNION PACIFIC RAILROAD
COMMON AS 1ISCLOSED by DIED RtcoRDED UNDER BEcOEDtNG NO. 75070705021
ALSO INCEPT THAT PORTION OF SAID Se7F,DIVISIOX DrSCSIOTD AS rolLoasi
> +EGINNIMO AT A POINT OW TIE WESTERLY hA6'OIN 07 ANDOVER PARH NEST. WNIC
POINT OURS NORTH £8005•42" WEST 1369.3; PEI? ALONG THE NORTi;EaLY LINE
Or SAID SOUTHEAST QUARTER. AHD $OLEO 01 +47'29" PEST 051.30 FEET ALONG
SAID WESTERLY MARGIN OP ANBOYEB PATE YCST PROM THE NORTHEAST CORNER OF
SAID 3OUTNZASY (UALIER; TMENC$ PEON $AID POINT Of BEGINNING LEAVING
SAID WESTERLY MARGIN, TAiii.YNT TO TOE PRECEDING COUISS, AloN; INC A &C 0
A CURVE TO THE 32GUT NAMING A EAOSUE OF 50.00 FM AND A CENTRAL ANGLE
Of 90005'49" AN AOC LENGTH 3? 78.64 ?err TO A POINT OW A LIAR THAT IS
PARALLYb TO AND 501.40 PERT SOU?MEYLY OP THE NORTHERLY LINE Or SAID
SOUTHEAST QUAltal; THENCE ALONG SLID PARALLEL LINK' MONTS 08005'42"
WEST 326„76 PEET; ?NENC! LEAVING LAST SAID PACALL!L LINE TANGENT TO TN!
PRECEDING COuR3F ALONG TEE ACC OF A CUENZ TO Tar RUNT HAYING A BADIUS
OF 15.00 PEEL' AND A CENTRAL AWLS Of 54005'560, AU ARC DISTANCE OP
14.34 FEE To A POINT Of REVERS! CURVATURE; THENCE TAHCCNT TO THE
PRECEDING CURVE ALONG 7EE ABC OF A CUM; TO THE LEFT. NAVING A RADIUS
OF 50.00 FEET AND A CENTRAL ANGLE OF 289031.52" AH ANC DISTANCE Of
152.56 UT? TO A POINT 0! REVERSE CURVATURE; TNENCC TANGENT 70 THE
PRECEDING CURVE ALONG Tilt ARC 07 a CURVE TO TB! RIGNi't, SAVING A RADIUS
OP 14 -00 TEtt AND A CENTRAL AMC Or 5$85.54 0. AN ,ARC LING ?N 0P 14.30
rztT.TO A LINE THAT I3 PARALLEL TO AND 546.40 PERT SOUTHERLY Or THE
NORTHERLY LINK Or $410 SOUTNIA3T QUARTER% THENCE ALONG SAID PARALLEL
LIME 80U'8 880OS442' EASE 377.05 1E5t1 ?$!NIZ! LEAVING SAID PARALLEL
LINE. TANGENT TO re* PBEC!D:xo COURSE, ALONG YN! ADC OF ! Cu2V2 TO toe
RXGH ?. NAvINO a RADIUS 0? 50.00 PEEP AND A CEHYIA!. ANGLE OP 89453•110,
AM ARC LENGTH OF 78.40 PUTT TO A POINT OM THE WESTERLY 1tANGIH Or
ANDOVER mg WEST; ?4!t:C/ ALONG SAID V!STLBLY Ni.SGIN NOM 01047129"
LAST 145,00 FEET To THE POINT OF OCGI »KING;
ALSO EXCEPT /MAT PORTION HOBS PAITICULACL7 DESCRIBED P. FOLLOWS:
B EGINNING AT A POINT ON THE WESTERLY MARGIN OF AMIOVEB PARK WEST
WHICH POINT SCARS N08YN 90405042" NEST 1,)69.3; ran? a'.0NG ?Nt
NONTNCRt.Y LINE OP SAID 33UTUUASY QUARTER ANA SOUTH 01047'29" YES?
4Y;1.)O PELT A1.0144 351D WESTERLY MU0!14 Or ANDOV}t! PAM; WEST fb0H Tat
40PTHZAST CORNER OF SAID SOUTi 3? QUARTERS
THENCE PROM SAZP POINT 0r BEGINNING LEAVING SAID W3%TIRLY MAPG't1,
TANGENT tO TEE PRECEDING C)U83E. ALONG TOR ARC nr A CURY,2 TO THE
N IGCT BAYING A RADIUS 0? 30.00 TETT AND A CENTRAL ANGLE OF
90006'69", AM AEC LBNGTN 0!'78.$4 PUT TO A POINT ON A LINE T'dAT IS
PARALLEL TO &iu 1,G3S.40 ttr SOUTNflLY Of TNC NORTHERLY LINE OP 3010
3OUTMEAR? QUA1TZR:
THENCE ALONG $1D PARALLEL LEN! NORTE 8b005'l2" MIST 325.76 PES1:
THENCE LEAVING /ASV 1419 PAAALL!L L214S TIMM TC fit PRECEDING
COURSE-ALONG THE ANC OP A CMS TO TAN RUST NAVIMO A RADIUS Or
15.00 PREY AMA a CENTRAL AM0L! Of 540454560. AN AQC DISTANCE OF
14.34 PRET TO A POINT OP MUM CJ V411ZIt;
?NIECE TANGENT TO ?MI PRECEDING CUDVY ALONG ENE ARC OP A COBV! TO
TIE LEFT MARINO A RADIUS OF 50.00 PBBV AND A CENTRAL ANLL! OP
289031 "520. AA1 ARC 0/STANCE Of 252.66, YERT 74 A POINT OF NETERSa
CUM/ARUM
THENCE TANGENT TO TR! OSICEBIN3 CURE ALGNO TAN 8!C OF A MVO T0.
YNI RIOteT BAYING A RADIUS OF 15.00 ?MIT AND A CENTRAL ANGLE Of
S4043'364. AN ADC DINOTS or 14.31 ?EDT TO A LINK *Nat ZS PARALLEL TO
•;ID 1.86$405 PEET $04Yi!RLY OF TM; NOSTRUM/ LIME Of SAID SOUTHEAST
MAMMA ?NEDC! ALONG SATS PARALLEL RIM! SOUSE 88435'43t" EAST 127.03
PITT; tw!NC1 MYTHS SAID PABALLCL LIAQ, 4ANBEUV 70 T%t8 PH CTOIRO
COURSE. ALARA ?MR ARC or 4 CURTI YO TAR SIGHT RAVING d HADIus Or 50.00
PERT AND A CENTRAL ARC.Y Of 8$4tb• 11 °, A!< ARC AIMS OF 74.44 'SST TO f
FOIST me Elk asITRNLY MASSES DIP mom PANS W85T; 'MICE AL4so SAID
WESTERLY NAPOIN NORTE. 010471214' ;AS? 14*.00 7I5T Y8 TAX POINT OP
q!OIRMINei.
A
FILE COP
understand that th3 Man Check approvals are
subject to errors and omissions and approval of
plans doses not eithOliZe thee vlotatlon of any
adopted code oe o co thz r'ae
ce!'1v et 4
SEPARATE, PEI
PE( RED F
HANI
LECTRIC
0 PLUMBIN(
❑ GAS PIPE
CITY OF Tilt
BUILDING DV
tT-}fry i W
I:1., f, ^Ell, !1'iliir 'l1i'1'�'T.� �•iTf. rtf:if iT 11'!1 1.t
111
r ' Il•f lt.�ia f ! at1T�' .., . .k•;
.w w
PROJECT I
SCHEME
DETAILS
EINIMMIBIORTM
ISTIONIMIERVIESEMBESTIMIM
esittinfil
YM 'r iCr£JwM) lKi,'!'.! "� +j•✓JC' +y. 4.f> !�'^.�9C�'7N
:
� :p. I ;� ,I , ��.ff;; ;l.L��I• I' !1 � ; `�I,{' =FfIIitromFii �111i1
4 5 6 I
r rr�
st. bRf 4
;v:4n+'�' 4v y'�. *4 J47+.Ii 44=; a'.47- ,9,41XRXR•orpO i 2 e,04,41.1441%fAta`o °i *-W7a,r,.Lrld, isY r^:
NOTE: If the microfilmed document is leas clear than this
notice, it is due to the quality of the original document.
Meese -AairealkieeiMieeise
•
L 9 h £ Z L wW 0
%III 411llllrl IHI lilkhdlinhIHIMlllflll 'lllilnlli1Illill)
1
ii
1
r -
1
NEW TENANT WALL
AREA SEPERATION WALL
Ma•��$. r+" .�-GN -I-, 4
Lit) r.:r1 fc'f,;Ci�.4►. =�
`G•
FLOOR MOUNTED TELEPHONE
THERMOSTAT + 60"
LIGHT TOGGLE SWITCH + 42"
3-WAY LIGHT TOGGLE SWICH
TYP. SPACING FOR WALL OUTLETS
EXISTING TO REMAIN
F.D. FLOOR DRAIN
Fr FEET
F.F.
FIN. FINISH
F1R. FLOOR
FIG. FOOTING
FND. FOUNDATION
F.O.G. FACE OF CONCRETE
F.O.F. FACE OF FRAMING
GA, GAUGE
GL. GLASS
G.L.B. GLU- LAMINATED BEAM
GYP. GYPSUM
G.W.B. GYPSUM WALL BOARD
HDWR. HARDWARE
HGT. HE1GIiT
FRCP. HANDICAP
HR. HOUR
HORIZ. HORIZONTAL
INSUL INSULATE (INSULATION)
INT. INTERIOR
JOINT
JOIST
LAVATORY
sFR, , MANUFACTURER . • '
MAIL. MATERIAL.'
MAX. MAXIMUM
MECH. MEcHANIGAS.
MIL. METAL
MIN. MINIMUM
MIX MIXTURE
NOT TO SCALE
NO. (0 NUMBER
OFF. OFFICE
0.0, ON CENTER
OPNG, OPENING
PNL. PANEL
PTN. PARTITION
PL. PLATE
PL.LAM. PLASTIC LAMINATE
PLYWD. PLYWOOD
P.L. PROPERTY LINE
P &P PATCH &PAINT
R.B. RUBBER BASE
REC. RECEPTION
RECP. RECEPTACLE
REINF, REINFORCING
R.Q. ROOF DRAIN
RM. ROOM
SDG. SIDING
SPEC. SPECIFICATION
STD. STANDARD
STL STEEL
STRUCT. STRUCTURAL
S & V STAIN iS VARNI$H
TELE. TELEPHONE
TEMP. TEMPERED
T. TOILET
T.O.P. TOP OF PARAPET
TYP. TYPICAL .
T.I. TENANT IMPROVEMENT
T.W.C. TACKABLE WALL COVERING
U.O.N. UNLESS OTHERWISE NOTED
V.C.T. VINYL COMPOSITION 'TILE
v.W.c. VINYL WALL COVERING
VENT. VENTILATE
VERT, VERTICAL
W. C, WATER CLOSET
W.COV. WALL COVERING
W.H. WATER HEATER
W.R. WATER RESISTANT
WD. WOOD
Iffit
- - -- - e - he \.10U4ai A'.e.
-2 G%
T.C.W. REALTY ADVISORS
TENANT DOOR HEAD TYP.
T „
NANT DEMISING WALL
1 RN rp.-to C:JiI
eteftscoOsNrIZel.:( TYP;
CW4 Fi•eib...f`4 it ;err
4D142," MaTA.L 'r^1
!x14: 4:0 m
.•'� 11
1 4 '% c FAAMS.
14 4.14 4.
(T") dU /.4 -I- eKI
1. All materials and workmanship sha11 conform to the 1991
Uniform Building, Mechanical and Electrical Codas or most
recently adopted edition.
2. Typical detatla 0101 apply where no specific details are
given.
3. The contractor shall verify all dia4ensioes, elevations,
ani existing conditions prior to construction.
4. All dimensions are to teeke precedence over scale shown on
plans, elevations, sections and details.
5. All exit doors to be operable from inside building
without keys or special knowledge.
6. Work related to tenant improvement and required
coordination to shell construction shall-be determined by
'the General Contractor for bidding and contractual
agreement.
7, Walls are to by flrestopeeNd per UBC Suction 2514(f).
8. Fire extinguishers shall be provided per NF'PA #1D, Hose
stations to he located per local agency requirements.
9. Doors not numbered are existing doors and are to remain.
1D. All interior ewallcovering materials sh311 be fire
resistive or shall be treated to be fire resistive, se as
to result in a flame spread rating of at least Class III
for general areas, Class II for exitways, and Class I for
enclosed' vertical exltways. Deliver certificate to the •
local fire department.
11. Install sprinklers according to drawings approved by City
of Tukwila Fire Marshall.
12. All equals to be submitted to 'architect for review prior
to construction.
13. Bid design work to be reviewed by architect prior to
construction,
TNAt PORTION Or ?NE IAS3 AALr or THE NORTHEAST QUANTLY Or THE
SoutoCAST QUARTER Or SECTION c:., TOWN3NIP 23 NOa?H, RANor 4 EAST,
Y.N., IN KING COUNTY. WASHINGTON DASCRI$RD AS FOLLOWS:
B EGINNING AT TEE NORTHEAST CORNER Or SAID CAS' HALO WHICH IS NORTH
8$403•42' WEST ALOon THE MONTH LIdt Or SAID SOUTHEAST QUARTER A
DISTANCE 07 1.119.34 FRET 'EON TOE NORTHEAST COINED Or SAID SOUTHEAST
• QUARTER; THLNCs sOUTII 01047.2!" LEES? ALONG VAC EASE LINE Or SAID LEAST
N air A DISTANCE 0! 1.)22.3$ FEET TO TNT $GUTRTA$T CORNED ?HEMP;
THENCE NORtN 0705540/0 HUT AL0116 Tel ROUTE !!Mt Or SAID ':Its? NAL? A
DISTANCE 'Of 63005 PICT TO TIE MAST Li,E Or TNC EaRT 65',34 PM' or
SAID Iii ST ESL*'; ?NEMCC %PORTN 014,47'l9" FAST ALOIta SAID NEST LINE A
DISTANCE Or 1,320.30 Ytt7 TO TNI MORTI LIRE Or SAID Ells? HALT% TMIECE
s0UTN 00.03.42" a :AST ALONG SAID MOMTM LIX! A DISTANCE OY 659.34 'ter
TO THE POINT Or BEGINNING;
EXCEPT THE BAST 30 PERT TBENEOF YOB ROAD;
ALSO EXCEPT 9311.11O4D Tl r. &GA AS RESERVED SY UNION PACIFIC RAILROAD
COMMON AS 1ISCLOSED by DIED RtcoRDED UNDER BEcOEDtNG NO. 75070705021
ALSO INCEPT THAT PORTION OF SAID Se7F,DIVISIOX DrSCSIOTD AS rolLoasi
> +EGINNIMO AT A POINT OW TIE WESTERLY hA6'OIN 07 ANDOVER PARH NEST. WNIC
POINT OURS NORTH £8005•42" WEST 1369.3; PEI? ALONG THE NORTi;EaLY LINE
Or SAID SOUTHEAST QUARTER. AHD $OLEO 01 +47'29" PEST 051.30 FEET ALONG
SAID WESTERLY MARGIN OP ANBOYEB PATE YCST PROM THE NORTHEAST CORNER OF
SAID 3OUTNZASY (UALIER; TMENC$ PEON $AID POINT Of BEGINNING LEAVING
SAID WESTERLY MARGIN, TAiii.YNT TO TOE PRECEDING COUISS, AloN; INC A &C 0
A CURVE TO THE 32GUT NAMING A EAOSUE OF 50.00 FM AND A CENTRAL ANGLE
Of 90005'49" AN AOC LENGTH 3? 78.64 ?err TO A POINT OW A LIAR THAT IS
PARALLYb TO AND 501.40 PERT SOU?MEYLY OP THE NORTHERLY LINE Or SAID
SOUTHEAST QUAltal; THENCE ALONG SLID PARALLEL LINK' MONTS 08005'42"
WEST 326„76 PEET; ?NENC! LEAVING LAST SAID PACALL!L LINE TANGENT TO TN!
PRECEDING COuR3F ALONG TEE ACC OF A CUENZ TO Tar RUNT HAYING A BADIUS
OF 15.00 PEEL' AND A CENTRAL AWLS Of 54005'560, AU ARC DISTANCE OP
14.34 FEE To A POINT Of REVERS! CURVATURE; THENCE TAHCCNT TO THE
PRECEDING CURVE ALONG 7EE ABC OF A CUM; TO THE LEFT. NAVING A RADIUS
OF 50.00 FEET AND A CENTRAL ANGLE OF 289031.52" AH ANC DISTANCE Of
152.56 UT? TO A POINT 0! REVERSE CURVATURE; TNENCC TANGENT 70 THE
PRECEDING CURVE ALONG Tilt ARC 07 a CURVE TO TB! RIGNi't, SAVING A RADIUS
OP 14 -00 TEtt AND A CENTRAL AMC Or 5$85.54 0. AN ,ARC LING ?N 0P 14.30
rztT.TO A LINE THAT I3 PARALLEL TO AND 546.40 PERT SOUTHERLY Or THE
NORTHERLY LINK Or $410 SOUTNIA3T QUARTER% THENCE ALONG SAID PARALLEL
LIME 80U'8 880OS442' EASE 377.05 1E5t1 ?$!NIZ! LEAVING SAID PARALLEL
LINE. TANGENT TO re* PBEC!D:xo COURSE, ALONG YN! ADC OF ! Cu2V2 TO toe
RXGH ?. NAvINO a RADIUS 0? 50.00 PEEP AND A CEHYIA!. ANGLE OP 89453•110,
AM ARC LENGTH OF 78.40 PUTT TO A POINT OM THE WESTERLY 1tANGIH Or
ANDOVER mg WEST; ?4!t:C/ ALONG SAID V!STLBLY Ni.SGIN NOM 01047129"
LAST 145,00 FEET To THE POINT OF OCGI »KING;
ALSO EXCEPT /MAT PORTION HOBS PAITICULACL7 DESCRIBED P. FOLLOWS:
B EGINNING AT A POINT ON THE WESTERLY MARGIN OF AMIOVEB PARK WEST
WHICH POINT SCARS N08YN 90405042" NEST 1,)69.3; ran? a'.0NG ?Nt
NONTNCRt.Y LINE OP SAID 33UTUUASY QUARTER ANA SOUTH 01047'29" YES?
4Y;1.)O PELT A1.0144 351D WESTERLY MU0!14 Or ANDOV}t! PAM; WEST fb0H Tat
40PTHZAST CORNER OF SAID SOUTi 3? QUARTERS
THENCE PROM SAZP POINT 0r BEGINNING LEAVING SAID W3%TIRLY MAPG't1,
TANGENT tO TEE PRECEDING C)U83E. ALONG TOR ARC nr A CURY,2 TO THE
N IGCT BAYING A RADIUS 0? 30.00 TETT AND A CENTRAL ANGLE OF
90006'69", AM AEC LBNGTN 0!'78.$4 PUT TO A POINT ON A LINE T'dAT IS
PARALLEL TO &iu 1,G3S.40 ttr SOUTNflLY Of TNC NORTHERLY LINE OP 3010
3OUTMEAR? QUA1TZR:
THENCE ALONG $1D PARALLEL LEN! NORTE 8b005'l2" MIST 325.76 PES1:
THENCE LEAVING /ASV 1419 PAAALL!L L214S TIMM TC fit PRECEDING
COURSE-ALONG THE ANC OP A CMS TO TAN RUST NAVIMO A RADIUS Or
15.00 PREY AMA a CENTRAL AM0L! Of 540454560. AN AQC DISTANCE OF
14.34 PRET TO A POINT OP MUM CJ V411ZIt;
?NIECE TANGENT TO ?MI PRECEDING CUDVY ALONG ENE ARC OP A COBV! TO
TIE LEFT MARINO A RADIUS OF 50.00 PBBV AND A CENTRAL ANLL! OP
289031 "520. AA1 ARC 0/STANCE Of 252.66, YERT 74 A POINT OF NETERSa
CUM/ARUM
THENCE TANGENT TO TR! OSICEBIN3 CURE ALGNO TAN 8!C OF A MVO T0.
YNI RIOteT BAYING A RADIUS OF 15.00 ?MIT AND A CENTRAL ANGLE Of
S4043'364. AN ADC DINOTS or 14.31 ?EDT TO A LINK *Nat ZS PARALLEL TO
•;ID 1.86$405 PEET $04Yi!RLY OF TM; NOSTRUM/ LIME Of SAID SOUTHEAST
MAMMA ?NEDC! ALONG SATS PARALLEL RIM! SOUSE 88435'43t" EAST 127.03
PITT; tw!NC1 MYTHS SAID PABALLCL LIAQ, 4ANBEUV 70 T%t8 PH CTOIRO
COURSE. ALARA ?MR ARC or 4 CURTI YO TAR SIGHT RAVING d HADIus Or 50.00
PERT AND A CENTRAL ARC.Y Of 8$4tb• 11 °, A!< ARC AIMS OF 74.44 'SST TO f
FOIST me Elk asITRNLY MASSES DIP mom PANS W85T; 'MICE AL4so SAID
WESTERLY NAPOIN NORTE. 010471214' ;AS? 14*.00 7I5T Y8 TAX POINT OP
q!OIRMINei.
A
FILE COP
understand that th3 Man Check approvals are
subject to errors and omissions and approval of
plans doses not eithOliZe thee vlotatlon of any
adopted code oe o co thz r'ae
ce!'1v et 4
SEPARATE, PEI
PE( RED F
HANI
LECTRIC
0 PLUMBIN(
❑ GAS PIPE
CITY OF Tilt
BUILDING DV
tT-}fry i W
I:1., f, ^Ell, !1'iliir 'l1i'1'�'T.� �•iTf. rtf:if iT 11'!1 1.t
111
r ' Il•f lt.�ia f ! at1T�' .., . .k•;
.w w
PROJECT I
SCHEME
DETAILS
EINIMMIBIORTM
ISTIONIMIERVIESEMBESTIMIM
esittinfil
YM 'r iCr£JwM) lKi,'!'.! "� +j•✓JC' +y. 4.f> !�'^.�9C�'7N
:
� :p. I ;� ,I , ��.ff;; ;l.L��I• I' !1 � ; `�I,{' =FfIIitromFii �111i1
4 5 6 I
r rr�
st. bRf 4
;v:4n+'�' 4v y'�. *4 J47+.Ii 44=; a'.47- ,9,41XRXR•orpO i 2 e,04,41.1441%fAta`o °i *-W7a,r,.Lrld, isY r^:
NOTE: If the microfilmed document is leas clear than this
notice, it is due to the quality of the original document.
Meese -AairealkieeiMieeise
•
L 9 h £ Z L wW 0
%III 411llllrl IHI lilkhdlinhIHIMlllflll 'lllilnlli1Illill)
1
is
i...\•. 1 4,J(✓r e;tii .?n. r.ur .,,�. t.l,4fi:4'
!r.
•
•
• .,
o r
•r lk
, .1
fid � ,�••�;
♦`H t•
n m.
•
R
SECOND FLOOR
8,693 SF.
• !U
r 0
aiI
E ALAN
NW
iki
yi 6l 1 N61
2! lI
c.oUNTRF. 2)6Hk 2,4174'
p.on O+G+ tvLiNtti� SAS
r SPt 0 sH -1-1U lvb GIB,
tKINT1 K.oOM
11.17 1
KLEc,"TRICAL 6PECCPICATIONS FOR PAYCIIEn SEATTLE °FEICK 095,
THE SERVICE ,PANEL FEEUIIIG OUR COMPUTER EQUIPMENT MUST
A 120/200 VOLT 3 PHASE PANEL CONSISTING OF A MtN1MUM OF
CO DUCTOR5. ALL OF THE CONDUCTORS MUST 'BE THE SANE GAU E
till WITH TIIE EXCEPTION OF THE ISOLAT'r,D GROUND, WHICH M T
i!E MINIMUM :iIZE OF +12 GAUGE COPPER TARN WIRE. s, OF RE
CON CTORS WILL OE THE PHASE VOLTAGES, ONE OF THE CON »UC' OI U
WILL. E THE NEUTRAL, ONE OF THE CONDUCTORS WILL DE THE S ETY
GROUN -WHICH WILL ,BOND TIIE CASE OF THE SERVICE PANEL AND
ONE 0 THE CONDUCTORS WILL ne THE ISOLATED GROUND OUR THIS
ISOf.AT GROUND WIRE MUST BE INSULATED Arm ISOLATED F EI THE
SERVICE PANEL. CONTINUOUS DACE: 'r0 THE XO OF THE MAIN KRVICE
ENTRANC TRANSFORMER, AND UOND SECURELY TO RUILDING STEEL,
W
COL, AT' ( PIPE„ AND GROUND HOD. Tills CRoUNO Sf5'r)M IS
E:SSENTIAI. TO ENSURE; A LOW RESISTANCE, NOISE: FREE OR( ND PATH
FOR OUR C. WOTErt E)UIPMENT.
THIS RCUIT, IS A 200 VOLT 40 Amp :MOLE PHASE DEDICATED
IRCUIT WITI AN ISOLATED GROI/ND, (' ONSISTING OF NUMBER, 1)
GAUGE:WIRES. 2 OF THE CONDUCTORS WILL HE THE PI SE VU(:TAGE
(200 VOLTS), 1 CONDUCTOR WILL HE THE SAFETY 0I UND, WHICH
WILL .00NO TIT.. SAFETY SWITCH AND THE. CASE OF OUR . UP's
EQUIPMENT, AND 1 CONDUCTOR WILL UE THE ISOLATE' GROUND. THIS
CIRCUt? MUST Nb, SHARK.ANY CONDUCTORS WITH ANY GTRER CIRCUIT
BACK TO TIIE SER ICE: PANEL. THIS CIRCUIT MUST T tMiNATK TO A 2
POLE FUSED SAFE SWITCH' EIOUINTED ON THE WALL. 3 FEET AHOVE THE
FLOOR.
93 NUMUE 10
THIS CIRCUIT 'S A 120. VOLT 30 AMP UEDIC FED CIRCUIT,FIITH
ISOGATEO .GROUND CONSISTING UE` CAUGI IJIRES.
THIS CIRCUIT MUST OT SHARE ANY CONDUCTOI • WITH ANY OTI1E:I(
C1RCUWT (LACK TO THE 'ERVICE PANEL. TL5-3011 twist LOCK)
® TPIS CIRCUIT, Is 120 VOLT :O AMP DE:ICATEI: CIRCUIT WITH
iC1J 1SOL,ATgD GROUND. •NSISTING OF 3 NU HER 12 GAUGE WIRES.
THIS CIRCUIT •MUST NOT • SHARE ANY CONUUs• ORS WITH ANY OTHER
- CIRCUIT BACK TO THE SE ICE PANEL.
THIS CIRCUIT IS A 200 WILT 20 AMP DEDICATED CIRCUIT
. TH A ISOLATED,GROUND,CONSISTING CF 5 NUMBER 12 GAUGE WIRES.
WE MU$T NOT RELY ON CONDUIT FOR A GROUND PATH. THIS CIRCUIT
MUST NOT SHARE ANY CONDUCTORS WIT.i ANY OTHER CIRCUIT. BACK TO
THE SERVICE PANEL.
11THIS CIRCUIT IS A 120 WILT 20 AMP CIRCUIT WHICH WILL BE
0 UY STANDARD OFFICE 6QUI ?MENT, THIS CIRCUIT CAN BE DAISY
CHA7NED'TO. OTHER. RECEPTACLES. WE WILL NOT BE USING ANY
COMPUTER EQUIPMENT ON THESE RECEPTACLES.
(PPE"DESIGNATES THE LOCATION FOR 1/2, INCH HOLLOW EMT
TYPE CONDUiiI FEEDS OR PHONE.AND COMPUTER CADC,E ACCESS.
T
THIS DESIGNATES THE LO TIO FOR 1 INCH HOLLOW ENT TYPE
ONDU.IT FEEDS FOR PHONE AND 'OMPUT: CARTE ACCESS.
THIS DESIGNATES TIIE CATION •2 INCH HOLLOW EMT TYPE
CONDUIT FEEDS FOR LARGE DI METER COMP TER CABLE ACCESS.
REGARDING AL ADOVE SPEC.IF CATIONS IAA
IF THE'LENGTII OF ANY WI E IS GREATER Ti
SIZE MUST RE INCREASED •Y ONE SIZE PER 1
N 100 FEET, THE WIRE
FEET.
RY A PAY CI1g
Fili#rMeEN- :ur1�j
iYtt* 11E�R1111t 1118 ∎0 0
:'7r•ill111111111a(IIwr.111
LIBIIIR11I■1Y11111 OUR
1011111111011W:' `. • .:::
1111*l
.AIR ENSI ! i.13NI £QR .UP e'
EACH - LOCATIOi AS DESCRIBED BY Hop) P:AtIE W
CONDITIONING EQU1 MENTTO COOL, AND,NAINTAIN A
TEMPERATURE OF 6• DEGREES FAHRENHEIT. ALL TH
WILL REQUIRE COO IRG AT ALL TIMES THESE AREAS
TYPE OF TIMER.
111121>RBOO
I PR11•IE 2755 O'fl (JTER SYSTEM
1 BEST POWER PS' SYSTEM SKVA
Z TELEPI,+3S TONE SYSTEM
C AREAS
(.L REQUIRE AIR
Opt STANT •
SE LOt;AT:ONS
T NOT BE ANY
15.000 BTU
3,000 ' D:'U
3.000 'DTU
TOTAL 21,000 ETU
15.1.114Vg
3.GEN1CO3 LINE PRINTERS
2 XEROX ASER.PRINTERS
1 TROY E CIl PRINTER
PACK' )• M
THE EA HARKED pA0:C1NG.WILL REQUIRE NOREIAL AIR COND1TIONIN•
*RAT WILL NOT BE ON A TIMER, THIS LOCATION WILL SE OCCUPIE
BY I YCIIEX PERSONNEL AFTER NORMAL WORKING HOURS, AND
1+'EE ENDS.
JUNCTION BOX ABOVE CEILING
v
tz ;e7r �T 4 Wc$ 4 IDIVR
c,r-7 F-+Q a. r
,..., won .a, mo• uu. was 110•.~ 10■0•■••• -F 4r WSW w .IMP s s
r..1- 6 iy'.
e-oltot 14/
c. ice' t :
1 4, sJ
JIF
Typical Pant) tolnt
i1•' is
PERMIT' CENTER
SHEET`
F=I1.11014 p t 4e r�2
... L I Il,
,
do 6Z 9G LG 9i 5r Z *,Z ea
r r
I1111111111111I1111111111111111111 ;111111111111;!111111111
s•rM:.«..a,i�'drWy.3a si, :Jw':.G. .,- /,r: /.p., err(`: `•'- l...�+. v.r.,/31:), r.Qi ,+• ir: �. �aG ,rf.- �eS1''.�.'..Crr'%tr'.rs:' r� t� r ,A�
111 1j`trt, /ri .I1 + I twit
4
NOTE: If the microfilmed document is less clear than this
notice, it is due to the quality of the original document.
•
{ !_ 1!111!111 j! 11 1111111111 !I
9 t 10 11 IMDE W o€RMMY 12.
1
C Z L w:+l Q
1111!! 11111 1111;1,;1 !! 1!11111111
1111111111
CL ZL lL 01, fi 8 G 1 9
11* Illlll�y� ll!91411 Ei�!�iilll!f�li il!1!!
'�..'. -., r „'.'' r ' "•t.':' ..: : .�: � :S..Y .. r. 111(4.
?. PLY}, Yk 1,,44 ...»..., . _.. ...57`,A.r .o- o •..
ee
I
r'4
t•
T� EAST
WALL
SOUTH
CE
WEST � CEILING
MAT. _ilN51 I MAT. FIIIISH
\ . t 4 Oral + l: ,40∎7167N.1 ow. ex 4er r:Iye""' gke..
EXISTING v' X 4° LIGHT FIXTURE
PROPOSED 2' X 4' LIGHT FIXTURE
El EXISTING 2° X 2 LIGHT FIXTURE
PROPOSED 2' X 2' LIGHT FIXTURE
EXIST. FIXTURE TO BE RELOCATED
q RL:CESSED DOWNLIGHT
S-4A,
51-0"x. 914:
TENANT DEMISING WALL
1 HR RATED W/
SOUND BATT INSULATION
STUD & DRYWALL W/
SOUND 3ATT INSULATION
SLOT DIFFUSER
CEILING DIFFUSER
JUNCTION BOX ABOVE CEILING
DUPLEX OUTLET + 12"
FLOOR MOUNTED OUTLET
DUPLEX OUTLET + 42"
AEC T, ACOUSTICAL CEILING Tv
A.F.F. ABOW FINISHER FLOOR
ALUM, ALUMINUM
ASPH, ASPHALT
MOD. ANODIZED
BM, BEAI4
BD, BOARD
BLDG. BUILDING
BU('G. BI.00<ING .
"BIG. CEIU G
IL CENTERLINE . .
COL COLUMN
CONC. CONCRETE
CONST. CONSTRUCTION
CONT. CONTINIOU$
b/F DRINKING FOUNTIAN
b11.. DETAIL
DIA. DIAMETER
DIM. DIMENSION
D.S. DOWNSPOUT
DR. DOOR
DWG. DRAWING
E.F.T. EXT.INSULATING PANEL
ELEC. ELECTRIC
ELEV. ELEVATION
ENG, ENGINEER
EQ. EQUAL
EQUIP. EQUIPMENT
EXIST. EXISTING
EXP. EXPANSION
EXT. EXTERIOR
r -
1
NEW TENANT WALL
AREA SEPERATION WALL
Ma•��$. r+" .�-GN -I-, 4
Lit) r.:r1 fc'f,;Ci�.4►. =�
`G•
FLOOR MOUNTED TELEPHONE
THERMOSTAT + 60"
LIGHT TOGGLE SWITCH + 42"
3-WAY LIGHT TOGGLE SWICH
TYP. SPACING FOR WALL OUTLETS
EXISTING TO REMAIN
F.D. FLOOR DRAIN
Fr FEET
F.F.
FIN. FINISH
F1R. FLOOR
FIG. FOOTING
FND. FOUNDATION
F.O.G. FACE OF CONCRETE
F.O.F. FACE OF FRAMING
GA, GAUGE
GL. GLASS
G.L.B. GLU- LAMINATED BEAM
GYP. GYPSUM
G.W.B. GYPSUM WALL BOARD
HDWR. HARDWARE
HGT. HE1GIiT
FRCP. HANDICAP
HR. HOUR
HORIZ. HORIZONTAL
INSUL INSULATE (INSULATION)
INT. INTERIOR
JOINT
JOIST
LAVATORY
sFR, , MANUFACTURER . • '
MAIL. MATERIAL.'
MAX. MAXIMUM
MECH. MEcHANIGAS.
MIL. METAL
MIN. MINIMUM
MIX MIXTURE
NOT TO SCALE
NO. (0 NUMBER
OFF. OFFICE
0.0, ON CENTER
OPNG, OPENING
PNL. PANEL
PTN. PARTITION
PL. PLATE
PL.LAM. PLASTIC LAMINATE
PLYWD. PLYWOOD
P.L. PROPERTY LINE
P &P PATCH &PAINT
R.B. RUBBER BASE
REC. RECEPTION
RECP. RECEPTACLE
REINF, REINFORCING
R.Q. ROOF DRAIN
RM. ROOM
SDG. SIDING
SPEC. SPECIFICATION
STD. STANDARD
STL STEEL
STRUCT. STRUCTURAL
S & V STAIN iS VARNI$H
TELE. TELEPHONE
TEMP. TEMPERED
T. TOILET
T.O.P. TOP OF PARAPET
TYP. TYPICAL .
T.I. TENANT IMPROVEMENT
T.W.C. TACKABLE WALL COVERING
U.O.N. UNLESS OTHERWISE NOTED
V.C.T. VINYL COMPOSITION 'TILE
v.W.c. VINYL WALL COVERING
VENT. VENTILATE
VERT, VERTICAL
W. C, WATER CLOSET
W.COV. WALL COVERING
W.H. WATER HEATER
W.R. WATER RESISTANT
WD. WOOD
Iffit
- - -- - e - he \.10U4ai A'.e.
-2 G%
T.C.W. REALTY ADVISORS
TENANT DOOR HEAD TYP.
T „
NANT DEMISING WALL
1 RN rp.-to C:JiI
eteftscoOsNrIZel.:( TYP;
CW4 Fi•eib...f`4 it ;err
4D142," MaTA.L 'r^1
!x14: 4:0 m
.•'� 11
1 4 '% c FAAMS.
14 4.14 4.
(T") dU /.4 -I- eKI
1. All materials and workmanship sha11 conform to the 1991
Uniform Building, Mechanical and Electrical Codas or most
recently adopted edition.
2. Typical detatla 0101 apply where no specific details are
given.
3. The contractor shall verify all dia4ensioes, elevations,
ani existing conditions prior to construction.
4. All dimensions are to teeke precedence over scale shown on
plans, elevations, sections and details.
5. All exit doors to be operable from inside building
without keys or special knowledge.
6. Work related to tenant improvement and required
coordination to shell construction shall-be determined by
'the General Contractor for bidding and contractual
agreement.
7, Walls are to by flrestopeeNd per UBC Suction 2514(f).
8. Fire extinguishers shall be provided per NF'PA #1D, Hose
stations to he located per local agency requirements.
9. Doors not numbered are existing doors and are to remain.
1D. All interior ewallcovering materials sh311 be fire
resistive or shall be treated to be fire resistive, se as
to result in a flame spread rating of at least Class III
for general areas, Class II for exitways, and Class I for
enclosed' vertical exltways. Deliver certificate to the •
local fire department.
11. Install sprinklers according to drawings approved by City
of Tukwila Fire Marshall.
12. All equals to be submitted to 'architect for review prior
to construction.
13. Bid design work to be reviewed by architect prior to
construction,
TNAt PORTION Or ?NE IAS3 AALr or THE NORTHEAST QUANTLY Or THE
SoutoCAST QUARTER Or SECTION c:., TOWN3NIP 23 NOa?H, RANor 4 EAST,
Y.N., IN KING COUNTY. WASHINGTON DASCRI$RD AS FOLLOWS:
B EGINNING AT TEE NORTHEAST CORNER Or SAID CAS' HALO WHICH IS NORTH
8$403•42' WEST ALOon THE MONTH LIdt Or SAID SOUTHEAST QUARTER A
DISTANCE 07 1.119.34 FRET 'EON TOE NORTHEAST COINED Or SAID SOUTHEAST
• QUARTER; THLNCs sOUTII 01047.2!" LEES? ALONG VAC EASE LINE Or SAID LEAST
N air A DISTANCE 0! 1.)22.3$ FEET TO TNT $GUTRTA$T CORNED ?HEMP;
THENCE NORtN 0705540/0 HUT AL0116 Tel ROUTE !!Mt Or SAID ':Its? NAL? A
DISTANCE 'Of 63005 PICT TO TIE MAST Li,E Or TNC EaRT 65',34 PM' or
SAID Iii ST ESL*'; ?NEMCC %PORTN 014,47'l9" FAST ALOIta SAID NEST LINE A
DISTANCE Or 1,320.30 Ytt7 TO TNI MORTI LIRE Or SAID Ells? HALT% TMIECE
s0UTN 00.03.42" a :AST ALONG SAID MOMTM LIX! A DISTANCE OY 659.34 'ter
TO THE POINT Or BEGINNING;
EXCEPT THE BAST 30 PERT TBENEOF YOB ROAD;
ALSO EXCEPT 9311.11O4D Tl r. &GA AS RESERVED SY UNION PACIFIC RAILROAD
COMMON AS 1ISCLOSED by DIED RtcoRDED UNDER BEcOEDtNG NO. 75070705021
ALSO INCEPT THAT PORTION OF SAID Se7F,DIVISIOX DrSCSIOTD AS rolLoasi
> +EGINNIMO AT A POINT OW TIE WESTERLY hA6'OIN 07 ANDOVER PARH NEST. WNIC
POINT OURS NORTH £8005•42" WEST 1369.3; PEI? ALONG THE NORTi;EaLY LINE
Or SAID SOUTHEAST QUARTER. AHD $OLEO 01 +47'29" PEST 051.30 FEET ALONG
SAID WESTERLY MARGIN OP ANBOYEB PATE YCST PROM THE NORTHEAST CORNER OF
SAID 3OUTNZASY (UALIER; TMENC$ PEON $AID POINT Of BEGINNING LEAVING
SAID WESTERLY MARGIN, TAiii.YNT TO TOE PRECEDING COUISS, AloN; INC A &C 0
A CURVE TO THE 32GUT NAMING A EAOSUE OF 50.00 FM AND A CENTRAL ANGLE
Of 90005'49" AN AOC LENGTH 3? 78.64 ?err TO A POINT OW A LIAR THAT IS
PARALLYb TO AND 501.40 PERT SOU?MEYLY OP THE NORTHERLY LINE Or SAID
SOUTHEAST QUAltal; THENCE ALONG SLID PARALLEL LINK' MONTS 08005'42"
WEST 326„76 PEET; ?NENC! LEAVING LAST SAID PACALL!L LINE TANGENT TO TN!
PRECEDING COuR3F ALONG TEE ACC OF A CUENZ TO Tar RUNT HAYING A BADIUS
OF 15.00 PEEL' AND A CENTRAL AWLS Of 54005'560, AU ARC DISTANCE OP
14.34 FEE To A POINT Of REVERS! CURVATURE; THENCE TAHCCNT TO THE
PRECEDING CURVE ALONG 7EE ABC OF A CUM; TO THE LEFT. NAVING A RADIUS
OF 50.00 FEET AND A CENTRAL ANGLE OF 289031.52" AH ANC DISTANCE Of
152.56 UT? TO A POINT 0! REVERSE CURVATURE; TNENCC TANGENT 70 THE
PRECEDING CURVE ALONG Tilt ARC 07 a CURVE TO TB! RIGNi't, SAVING A RADIUS
OP 14 -00 TEtt AND A CENTRAL AMC Or 5$85.54 0. AN ,ARC LING ?N 0P 14.30
rztT.TO A LINE THAT I3 PARALLEL TO AND 546.40 PERT SOUTHERLY Or THE
NORTHERLY LINK Or $410 SOUTNIA3T QUARTER% THENCE ALONG SAID PARALLEL
LIME 80U'8 880OS442' EASE 377.05 1E5t1 ?$!NIZ! LEAVING SAID PARALLEL
LINE. TANGENT TO re* PBEC!D:xo COURSE, ALONG YN! ADC OF ! Cu2V2 TO toe
RXGH ?. NAvINO a RADIUS 0? 50.00 PEEP AND A CEHYIA!. ANGLE OP 89453•110,
AM ARC LENGTH OF 78.40 PUTT TO A POINT OM THE WESTERLY 1tANGIH Or
ANDOVER mg WEST; ?4!t:C/ ALONG SAID V!STLBLY Ni.SGIN NOM 01047129"
LAST 145,00 FEET To THE POINT OF OCGI »KING;
ALSO EXCEPT /MAT PORTION HOBS PAITICULACL7 DESCRIBED P. FOLLOWS:
B EGINNING AT A POINT ON THE WESTERLY MARGIN OF AMIOVEB PARK WEST
WHICH POINT SCARS N08YN 90405042" NEST 1,)69.3; ran? a'.0NG ?Nt
NONTNCRt.Y LINE OP SAID 33UTUUASY QUARTER ANA SOUTH 01047'29" YES?
4Y;1.)O PELT A1.0144 351D WESTERLY MU0!14 Or ANDOV}t! PAM; WEST fb0H Tat
40PTHZAST CORNER OF SAID SOUTi 3? QUARTERS
THENCE PROM SAZP POINT 0r BEGINNING LEAVING SAID W3%TIRLY MAPG't1,
TANGENT tO TEE PRECEDING C)U83E. ALONG TOR ARC nr A CURY,2 TO THE
N IGCT BAYING A RADIUS 0? 30.00 TETT AND A CENTRAL ANGLE OF
90006'69", AM AEC LBNGTN 0!'78.$4 PUT TO A POINT ON A LINE T'dAT IS
PARALLEL TO &iu 1,G3S.40 ttr SOUTNflLY Of TNC NORTHERLY LINE OP 3010
3OUTMEAR? QUA1TZR:
THENCE ALONG $1D PARALLEL LEN! NORTE 8b005'l2" MIST 325.76 PES1:
THENCE LEAVING /ASV 1419 PAAALL!L L214S TIMM TC fit PRECEDING
COURSE-ALONG THE ANC OP A CMS TO TAN RUST NAVIMO A RADIUS Or
15.00 PREY AMA a CENTRAL AM0L! Of 540454560. AN AQC DISTANCE OF
14.34 PRET TO A POINT OP MUM CJ V411ZIt;
?NIECE TANGENT TO ?MI PRECEDING CUDVY ALONG ENE ARC OP A COBV! TO
TIE LEFT MARINO A RADIUS OF 50.00 PBBV AND A CENTRAL ANLL! OP
289031 "520. AA1 ARC 0/STANCE Of 252.66, YERT 74 A POINT OF NETERSa
CUM/ARUM
THENCE TANGENT TO TR! OSICEBIN3 CURE ALGNO TAN 8!C OF A MVO T0.
YNI RIOteT BAYING A RADIUS OF 15.00 ?MIT AND A CENTRAL ANGLE Of
S4043'364. AN ADC DINOTS or 14.31 ?EDT TO A LINK *Nat ZS PARALLEL TO
•;ID 1.86$405 PEET $04Yi!RLY OF TM; NOSTRUM/ LIME Of SAID SOUTHEAST
MAMMA ?NEDC! ALONG SATS PARALLEL RIM! SOUSE 88435'43t" EAST 127.03
PITT; tw!NC1 MYTHS SAID PABALLCL LIAQ, 4ANBEUV 70 T%t8 PH CTOIRO
COURSE. ALARA ?MR ARC or 4 CURTI YO TAR SIGHT RAVING d HADIus Or 50.00
PERT AND A CENTRAL ARC.Y Of 8$4tb• 11 °, A!< ARC AIMS OF 74.44 'SST TO f
FOIST me Elk asITRNLY MASSES DIP mom PANS W85T; 'MICE AL4so SAID
WESTERLY NAPOIN NORTE. 010471214' ;AS? 14*.00 7I5T Y8 TAX POINT OP
q!OIRMINei.
A
FILE COP
understand that th3 Man Check approvals are
subject to errors and omissions and approval of
plans doses not eithOliZe thee vlotatlon of any
adopted code oe o co thz r'ae
ce!'1v et 4
SEPARATE, PEI
PE( RED F
HANI
LECTRIC
0 PLUMBIN(
❑ GAS PIPE
CITY OF Tilt
BUILDING DV
tT-}fry i W
I:1., f, ^Ell, !1'iliir 'l1i'1'�'T.� �•iTf. rtf:if iT 11'!1 1.t
111
r ' Il•f lt.�ia f ! at1T�' .., . .k•;
.w w
PROJECT I
SCHEME
DETAILS
EINIMMIBIORTM
ISTIONIMIERVIESEMBESTIMIM
esittinfil
YM 'r iCr£JwM) lKi,'!'.! "� +j•✓JC' +y. 4.f> !�'^.�9C�'7N
:
� :p. I ;� ,I , ��.ff;; ;l.L��I• I' !1 � ; `�I,{' =FfIIitromFii �111i1
4 5 6 I
r rr�
st. bRf 4
;v:4n+'�' 4v y'�. *4 J47+.Ii 44=; a'.47- ,9,41XRXR•orpO i 2 e,04,41.1441%fAta`o °i *-W7a,r,.Lrld, isY r^:
NOTE: If the microfilmed document is leas clear than this
notice, it is due to the quality of the original document.
Meese -AairealkieeiMieeise
•
L 9 h £ Z L wW 0
%III 411llllrl IHI lilkhdlinhIHIMlllflll 'lllilnlli1Illill)
1
ii
1
r -
1
NEW TENANT WALL
AREA SEPERATION WALL
Ma•��$. r+" .�-GN -I-, 4
Lit) r.:r1 fc'f,;Ci�.4►. =�
`G•
FLOOR MOUNTED TELEPHONE
THERMOSTAT + 60"
LIGHT TOGGLE SWITCH + 42"
3-WAY LIGHT TOGGLE SWICH
TYP. SPACING FOR WALL OUTLETS
EXISTING TO REMAIN
F.D. FLOOR DRAIN
Fr FEET
F.F.
FIN. FINISH
F1R. FLOOR
FIG. FOOTING
FND. FOUNDATION
F.O.G. FACE OF CONCRETE
F.O.F. FACE OF FRAMING
GA, GAUGE
GL. GLASS
G.L.B. GLU- LAMINATED BEAM
GYP. GYPSUM
G.W.B. GYPSUM WALL BOARD
HDWR. HARDWARE
HGT. HE1GIiT
FRCP. HANDICAP
HR. HOUR
HORIZ. HORIZONTAL
INSUL INSULATE (INSULATION)
INT. INTERIOR
JOINT
JOIST
LAVATORY
sFR, , MANUFACTURER . • '
MAIL. MATERIAL.'
MAX. MAXIMUM
MECH. MEcHANIGAS.
MIL. METAL
MIN. MINIMUM
MIX MIXTURE
NOT TO SCALE
NO. (0 NUMBER
OFF. OFFICE
0.0, ON CENTER
OPNG, OPENING
PNL. PANEL
PTN. PARTITION
PL. PLATE
PL.LAM. PLASTIC LAMINATE
PLYWD. PLYWOOD
P.L. PROPERTY LINE
P &P PATCH &PAINT
R.B. RUBBER BASE
REC. RECEPTION
RECP. RECEPTACLE
REINF, REINFORCING
R.Q. ROOF DRAIN
RM. ROOM
SDG. SIDING
SPEC. SPECIFICATION
STD. STANDARD
STL STEEL
STRUCT. STRUCTURAL
S & V STAIN iS VARNI$H
TELE. TELEPHONE
TEMP. TEMPERED
T. TOILET
T.O.P. TOP OF PARAPET
TYP. TYPICAL .
T.I. TENANT IMPROVEMENT
T.W.C. TACKABLE WALL COVERING
U.O.N. UNLESS OTHERWISE NOTED
V.C.T. VINYL COMPOSITION 'TILE
v.W.c. VINYL WALL COVERING
VENT. VENTILATE
VERT, VERTICAL
W. C, WATER CLOSET
W.COV. WALL COVERING
W.H. WATER HEATER
W.R. WATER RESISTANT
WD. WOOD
Iffit
- - -- - e - he \.10U4ai A'.e.
-2 G%
T.C.W. REALTY ADVISORS
TENANT DOOR HEAD TYP.
T „
NANT DEMISING WALL
1 RN rp.-to C:JiI
eteftscoOsNrIZel.:( TYP;
CW4 Fi•eib...f`4 it ;err
4D142," MaTA.L 'r^1
!x14: 4:0 m
.•'� 11
1 4 '% c FAAMS.
14 4.14 4.
(T") dU /.4 -I- eKI
1. All materials and workmanship sha11 conform to the 1991
Uniform Building, Mechanical and Electrical Codas or most
recently adopted edition.
2. Typical detatla 0101 apply where no specific details are
given.
3. The contractor shall verify all dia4ensioes, elevations,
ani existing conditions prior to construction.
4. All dimensions are to teeke precedence over scale shown on
plans, elevations, sections and details.
5. All exit doors to be operable from inside building
without keys or special knowledge.
6. Work related to tenant improvement and required
coordination to shell construction shall-be determined by
'the General Contractor for bidding and contractual
agreement.
7, Walls are to by flrestopeeNd per UBC Suction 2514(f).
8. Fire extinguishers shall be provided per NF'PA #1D, Hose
stations to he located per local agency requirements.
9. Doors not numbered are existing doors and are to remain.
1D. All interior ewallcovering materials sh311 be fire
resistive or shall be treated to be fire resistive, se as
to result in a flame spread rating of at least Class III
for general areas, Class II for exitways, and Class I for
enclosed' vertical exltways. Deliver certificate to the •
local fire department.
11. Install sprinklers according to drawings approved by City
of Tukwila Fire Marshall.
12. All equals to be submitted to 'architect for review prior
to construction.
13. Bid design work to be reviewed by architect prior to
construction,
TNAt PORTION Or ?NE IAS3 AALr or THE NORTHEAST QUANTLY Or THE
SoutoCAST QUARTER Or SECTION c:., TOWN3NIP 23 NOa?H, RANor 4 EAST,
Y.N., IN KING COUNTY. WASHINGTON DASCRI$RD AS FOLLOWS:
B EGINNING AT TEE NORTHEAST CORNER Or SAID CAS' HALO WHICH IS NORTH
8$403•42' WEST ALOon THE MONTH LIdt Or SAID SOUTHEAST QUARTER A
DISTANCE 07 1.119.34 FRET 'EON TOE NORTHEAST COINED Or SAID SOUTHEAST
• QUARTER; THLNCs sOUTII 01047.2!" LEES? ALONG VAC EASE LINE Or SAID LEAST
N air A DISTANCE 0! 1.)22.3$ FEET TO TNT $GUTRTA$T CORNED ?HEMP;
THENCE NORtN 0705540/0 HUT AL0116 Tel ROUTE !!Mt Or SAID ':Its? NAL? A
DISTANCE 'Of 63005 PICT TO TIE MAST Li,E Or TNC EaRT 65',34 PM' or
SAID Iii ST ESL*'; ?NEMCC %PORTN 014,47'l9" FAST ALOIta SAID NEST LINE A
DISTANCE Or 1,320.30 Ytt7 TO TNI MORTI LIRE Or SAID Ells? HALT% TMIECE
s0UTN 00.03.42" a :AST ALONG SAID MOMTM LIX! A DISTANCE OY 659.34 'ter
TO THE POINT Or BEGINNING;
EXCEPT THE BAST 30 PERT TBENEOF YOB ROAD;
ALSO EXCEPT 9311.11O4D Tl r. &GA AS RESERVED SY UNION PACIFIC RAILROAD
COMMON AS 1ISCLOSED by DIED RtcoRDED UNDER BEcOEDtNG NO. 75070705021
ALSO INCEPT THAT PORTION OF SAID Se7F,DIVISIOX DrSCSIOTD AS rolLoasi
> +EGINNIMO AT A POINT OW TIE WESTERLY hA6'OIN 07 ANDOVER PARH NEST. WNIC
POINT OURS NORTH £8005•42" WEST 1369.3; PEI? ALONG THE NORTi;EaLY LINE
Or SAID SOUTHEAST QUARTER. AHD $OLEO 01 +47'29" PEST 051.30 FEET ALONG
SAID WESTERLY MARGIN OP ANBOYEB PATE YCST PROM THE NORTHEAST CORNER OF
SAID 3OUTNZASY (UALIER; TMENC$ PEON $AID POINT Of BEGINNING LEAVING
SAID WESTERLY MARGIN, TAiii.YNT TO TOE PRECEDING COUISS, AloN; INC A &C 0
A CURVE TO THE 32GUT NAMING A EAOSUE OF 50.00 FM AND A CENTRAL ANGLE
Of 90005'49" AN AOC LENGTH 3? 78.64 ?err TO A POINT OW A LIAR THAT IS
PARALLYb TO AND 501.40 PERT SOU?MEYLY OP THE NORTHERLY LINE Or SAID
SOUTHEAST QUAltal; THENCE ALONG SLID PARALLEL LINK' MONTS 08005'42"
WEST 326„76 PEET; ?NENC! LEAVING LAST SAID PACALL!L LINE TANGENT TO TN!
PRECEDING COuR3F ALONG TEE ACC OF A CUENZ TO Tar RUNT HAYING A BADIUS
OF 15.00 PEEL' AND A CENTRAL AWLS Of 54005'560, AU ARC DISTANCE OP
14.34 FEE To A POINT Of REVERS! CURVATURE; THENCE TAHCCNT TO THE
PRECEDING CURVE ALONG 7EE ABC OF A CUM; TO THE LEFT. NAVING A RADIUS
OF 50.00 FEET AND A CENTRAL ANGLE OF 289031.52" AH ANC DISTANCE Of
152.56 UT? TO A POINT 0! REVERSE CURVATURE; TNENCC TANGENT 70 THE
PRECEDING CURVE ALONG Tilt ARC 07 a CURVE TO TB! RIGNi't, SAVING A RADIUS
OP 14 -00 TEtt AND A CENTRAL AMC Or 5$85.54 0. AN ,ARC LING ?N 0P 14.30
rztT.TO A LINE THAT I3 PARALLEL TO AND 546.40 PERT SOUTHERLY Or THE
NORTHERLY LINK Or $410 SOUTNIA3T QUARTER% THENCE ALONG SAID PARALLEL
LIME 80U'8 880OS442' EASE 377.05 1E5t1 ?$!NIZ! LEAVING SAID PARALLEL
LINE. TANGENT TO re* PBEC!D:xo COURSE, ALONG YN! ADC OF ! Cu2V2 TO toe
RXGH ?. NAvINO a RADIUS 0? 50.00 PEEP AND A CEHYIA!. ANGLE OP 89453•110,
AM ARC LENGTH OF 78.40 PUTT TO A POINT OM THE WESTERLY 1tANGIH Or
ANDOVER mg WEST; ?4!t:C/ ALONG SAID V!STLBLY Ni.SGIN NOM 01047129"
LAST 145,00 FEET To THE POINT OF OCGI »KING;
ALSO EXCEPT /MAT PORTION HOBS PAITICULACL7 DESCRIBED P. FOLLOWS:
B EGINNING AT A POINT ON THE WESTERLY MARGIN OF AMIOVEB PARK WEST
WHICH POINT SCARS N08YN 90405042" NEST 1,)69.3; ran? a'.0NG ?Nt
NONTNCRt.Y LINE OP SAID 33UTUUASY QUARTER ANA SOUTH 01047'29" YES?
4Y;1.)O PELT A1.0144 351D WESTERLY MU0!14 Or ANDOV}t! PAM; WEST fb0H Tat
40PTHZAST CORNER OF SAID SOUTi 3? QUARTERS
THENCE PROM SAZP POINT 0r BEGINNING LEAVING SAID W3%TIRLY MAPG't1,
TANGENT tO TEE PRECEDING C)U83E. ALONG TOR ARC nr A CURY,2 TO THE
N IGCT BAYING A RADIUS 0? 30.00 TETT AND A CENTRAL ANGLE OF
90006'69", AM AEC LBNGTN 0!'78.$4 PUT TO A POINT ON A LINE T'dAT IS
PARALLEL TO &iu 1,G3S.40 ttr SOUTNflLY Of TNC NORTHERLY LINE OP 3010
3OUTMEAR? QUA1TZR:
THENCE ALONG $1D PARALLEL LEN! NORTE 8b005'l2" MIST 325.76 PES1:
THENCE LEAVING /ASV 1419 PAAALL!L L214S TIMM TC fit PRECEDING
COURSE-ALONG THE ANC OP A CMS TO TAN RUST NAVIMO A RADIUS Or
15.00 PREY AMA a CENTRAL AM0L! Of 540454560. AN AQC DISTANCE OF
14.34 PRET TO A POINT OP MUM CJ V411ZIt;
?NIECE TANGENT TO ?MI PRECEDING CUDVY ALONG ENE ARC OP A COBV! TO
TIE LEFT MARINO A RADIUS OF 50.00 PBBV AND A CENTRAL ANLL! OP
289031 "520. AA1 ARC 0/STANCE Of 252.66, YERT 74 A POINT OF NETERSa
CUM/ARUM
THENCE TANGENT TO TR! OSICEBIN3 CURE ALGNO TAN 8!C OF A MVO T0.
YNI RIOteT BAYING A RADIUS OF 15.00 ?MIT AND A CENTRAL ANGLE Of
S4043'364. AN ADC DINOTS or 14.31 ?EDT TO A LINK *Nat ZS PARALLEL TO
•;ID 1.86$405 PEET $04Yi!RLY OF TM; NOSTRUM/ LIME Of SAID SOUTHEAST
MAMMA ?NEDC! ALONG SATS PARALLEL RIM! SOUSE 88435'43t" EAST 127.03
PITT; tw!NC1 MYTHS SAID PABALLCL LIAQ, 4ANBEUV 70 T%t8 PH CTOIRO
COURSE. ALARA ?MR ARC or 4 CURTI YO TAR SIGHT RAVING d HADIus Or 50.00
PERT AND A CENTRAL ARC.Y Of 8$4tb• 11 °, A!< ARC AIMS OF 74.44 'SST TO f
FOIST me Elk asITRNLY MASSES DIP mom PANS W85T; 'MICE AL4so SAID
WESTERLY NAPOIN NORTE. 010471214' ;AS? 14*.00 7I5T Y8 TAX POINT OP
q!OIRMINei.
A
FILE COP
understand that th3 Man Check approvals are
subject to errors and omissions and approval of
plans doses not eithOliZe thee vlotatlon of any
adopted code oe o co thz r'ae
ce!'1v et 4
SEPARATE, PEI
PE( RED F
HANI
LECTRIC
0 PLUMBIN(
❑ GAS PIPE
CITY OF Tilt
BUILDING DV
tT-}fry i W
I:1., f, ^Ell, !1'iliir 'l1i'1'�'T.� �•iTf. rtf:if iT 11'!1 1.t
111
r ' Il•f lt.�ia f ! at1T�' .., . .k•;
.w w
PROJECT I
SCHEME
DETAILS
EINIMMIBIORTM
ISTIONIMIERVIESEMBESTIMIM
esittinfil
YM 'r iCr£JwM) lKi,'!'.! "� +j•✓JC' +y. 4.f> !�'^.�9C�'7N
:
� :p. I ;� ,I , ��.ff;; ;l.L��I• I' !1 � ; `�I,{' =FfIIitromFii �111i1
4 5 6 I
r rr�
st. bRf 4
;v:4n+'�' 4v y'�. *4 J47+.Ii 44=; a'.47- ,9,41XRXR•orpO i 2 e,04,41.1441%fAta`o °i *-W7a,r,.Lrld, isY r^:
NOTE: If the microfilmed document is leas clear than this
notice, it is due to the quality of the original document.
Meese -AairealkieeiMieeise
•
L 9 h £ Z L wW 0
%III 411llllrl IHI lilkhdlinhIHIMlllflll 'lllilnlli1Illill)
1
is
i...\•. 1 4,J(✓r e;tii .?n. r.ur .,,�. t.l,4fi:4'
!r.
•
•
• .,
o r
•r lk
, .1
fid � ,�••�;
♦`H t•
n m.
•
R
SECOND FLOOR
8,693 SF.
• !U
r 0
aiI
E ALAN
NW
iki
yi 6l 1 N61
2! lI
c.oUNTRF. 2)6Hk 2,4174'
p.on O+G+ tvLiNtti� SAS
r SPt 0 sH -1-1U lvb GIB,
tKINT1 K.oOM
11.17 1
KLEc,"TRICAL 6PECCPICATIONS FOR PAYCIIEn SEATTLE °FEICK 095,
THE SERVICE ,PANEL FEEUIIIG OUR COMPUTER EQUIPMENT MUST
A 120/200 VOLT 3 PHASE PANEL CONSISTING OF A MtN1MUM OF
CO DUCTOR5. ALL OF THE CONDUCTORS MUST 'BE THE SANE GAU E
till WITH TIIE EXCEPTION OF THE ISOLAT'r,D GROUND, WHICH M T
i!E MINIMUM :iIZE OF +12 GAUGE COPPER TARN WIRE. s, OF RE
CON CTORS WILL OE THE PHASE VOLTAGES, ONE OF THE CON »UC' OI U
WILL. E THE NEUTRAL, ONE OF THE CONDUCTORS WILL DE THE S ETY
GROUN -WHICH WILL ,BOND TIIE CASE OF THE SERVICE PANEL AND
ONE 0 THE CONDUCTORS WILL ne THE ISOLATED GROUND OUR THIS
ISOf.AT GROUND WIRE MUST BE INSULATED Arm ISOLATED F EI THE
SERVICE PANEL. CONTINUOUS DACE: 'r0 THE XO OF THE MAIN KRVICE
ENTRANC TRANSFORMER, AND UOND SECURELY TO RUILDING STEEL,
W
COL, AT' ( PIPE„ AND GROUND HOD. Tills CRoUNO Sf5'r)M IS
E:SSENTIAI. TO ENSURE; A LOW RESISTANCE, NOISE: FREE OR( ND PATH
FOR OUR C. WOTErt E)UIPMENT.
THIS RCUIT, IS A 200 VOLT 40 Amp :MOLE PHASE DEDICATED
IRCUIT WITI AN ISOLATED GROI/ND, (' ONSISTING OF NUMBER, 1)
GAUGE:WIRES. 2 OF THE CONDUCTORS WILL HE THE PI SE VU(:TAGE
(200 VOLTS), 1 CONDUCTOR WILL HE THE SAFETY 0I UND, WHICH
WILL .00NO TIT.. SAFETY SWITCH AND THE. CASE OF OUR . UP's
EQUIPMENT, AND 1 CONDUCTOR WILL UE THE ISOLATE' GROUND. THIS
CIRCUt? MUST Nb, SHARK.ANY CONDUCTORS WITH ANY GTRER CIRCUIT
BACK TO TIIE SER ICE: PANEL. THIS CIRCUIT MUST T tMiNATK TO A 2
POLE FUSED SAFE SWITCH' EIOUINTED ON THE WALL. 3 FEET AHOVE THE
FLOOR.
93 NUMUE 10
THIS CIRCUIT 'S A 120. VOLT 30 AMP UEDIC FED CIRCUIT,FIITH
ISOGATEO .GROUND CONSISTING UE` CAUGI IJIRES.
THIS CIRCUIT MUST OT SHARE ANY CONDUCTOI • WITH ANY OTI1E:I(
C1RCUWT (LACK TO THE 'ERVICE PANEL. TL5-3011 twist LOCK)
® TPIS CIRCUIT, Is 120 VOLT :O AMP DE:ICATEI: CIRCUIT WITH
iC1J 1SOL,ATgD GROUND. •NSISTING OF 3 NU HER 12 GAUGE WIRES.
THIS CIRCUIT •MUST NOT • SHARE ANY CONUUs• ORS WITH ANY OTHER
- CIRCUIT BACK TO THE SE ICE PANEL.
THIS CIRCUIT IS A 200 WILT 20 AMP DEDICATED CIRCUIT
. TH A ISOLATED,GROUND,CONSISTING CF 5 NUMBER 12 GAUGE WIRES.
WE MU$T NOT RELY ON CONDUIT FOR A GROUND PATH. THIS CIRCUIT
MUST NOT SHARE ANY CONDUCTORS WIT.i ANY OTHER CIRCUIT. BACK TO
THE SERVICE PANEL.
11THIS CIRCUIT IS A 120 WILT 20 AMP CIRCUIT WHICH WILL BE
0 UY STANDARD OFFICE 6QUI ?MENT, THIS CIRCUIT CAN BE DAISY
CHA7NED'TO. OTHER. RECEPTACLES. WE WILL NOT BE USING ANY
COMPUTER EQUIPMENT ON THESE RECEPTACLES.
(PPE"DESIGNATES THE LOCATION FOR 1/2, INCH HOLLOW EMT
TYPE CONDUiiI FEEDS OR PHONE.AND COMPUTER CADC,E ACCESS.
T
THIS DESIGNATES THE LO TIO FOR 1 INCH HOLLOW ENT TYPE
ONDU.IT FEEDS FOR PHONE AND 'OMPUT: CARTE ACCESS.
THIS DESIGNATES TIIE CATION •2 INCH HOLLOW EMT TYPE
CONDUIT FEEDS FOR LARGE DI METER COMP TER CABLE ACCESS.
REGARDING AL ADOVE SPEC.IF CATIONS IAA
IF THE'LENGTII OF ANY WI E IS GREATER Ti
SIZE MUST RE INCREASED •Y ONE SIZE PER 1
N 100 FEET, THE WIRE
FEET.
RY A PAY CI1g
Fili#rMeEN- :ur1�j
iYtt* 11E�R1111t 1118 ∎0 0
:'7r•ill111111111a(IIwr.111
LIBIIIR11I■1Y11111 OUR
1011111111011W:' `. • .:::
1111*l
.AIR ENSI ! i.13NI £QR .UP e'
EACH - LOCATIOi AS DESCRIBED BY Hop) P:AtIE W
CONDITIONING EQU1 MENTTO COOL, AND,NAINTAIN A
TEMPERATURE OF 6• DEGREES FAHRENHEIT. ALL TH
WILL REQUIRE COO IRG AT ALL TIMES THESE AREAS
TYPE OF TIMER.
111121>RBOO
I PR11•IE 2755 O'fl (JTER SYSTEM
1 BEST POWER PS' SYSTEM SKVA
Z TELEPI,+3S TONE SYSTEM
C AREAS
(.L REQUIRE AIR
Opt STANT •
SE LOt;AT:ONS
T NOT BE ANY
15.000 BTU
3,000 ' D:'U
3.000 'DTU
TOTAL 21,000 ETU
15.1.114Vg
3.GEN1CO3 LINE PRINTERS
2 XEROX ASER.PRINTERS
1 TROY E CIl PRINTER
PACK' )• M
THE EA HARKED pA0:C1NG.WILL REQUIRE NOREIAL AIR COND1TIONIN•
*RAT WILL NOT BE ON A TIMER, THIS LOCATION WILL SE OCCUPIE
BY I YCIIEX PERSONNEL AFTER NORMAL WORKING HOURS, AND
1+'EE ENDS.
JUNCTION BOX ABOVE CEILING
v
tz ;e7r �T 4 Wc$ 4 IDIVR
c,r-7 F-+Q a. r
,..., won .a, mo• uu. was 110•.~ 10■0•■••• -F 4r WSW w .IMP s s
r..1- 6 iy'.
e-oltot 14/
c. ice' t :
1 4, sJ
JIF
Typical Pant) tolnt
i1•' is
PERMIT' CENTER
SHEET`
F=I1.11014 p t 4e r�2
... L I Il,
,
do 6Z 9G LG 9i 5r Z *,Z ea
r r
I1111111111111I1111111111111111111 ;111111111111;!111111111
s•rM:.«..a,i�'drWy.3a si, :Jw':.G. .,- /,r: /.p., err(`: `•'- l...�+. v.r.,/31:), r.Qi ,+• ir: �. �aG ,rf.- �eS1''.�.'..Crr'%tr'.rs:' r� t� r ,A�
111 1j`trt, /ri .I1 + I twit
4
NOTE: If the microfilmed document is less clear than this
notice, it is due to the quality of the original document.
•
{ !_ 1!111!111 j! 11 1111111111 !I
9 t 10 11 IMDE W o€RMMY 12.
1
C Z L w:+l Q
1111!! 11111 1111;1,;1 !! 1!11111111
1111111111
CL ZL lL 01, fi 8 G 1 9
11* Illlll�y� ll!91411 Ei�!�iilll!f�li il!1!!
'�..'. -., r „'.'' r ' "•t.':' ..: : .�: � :S..Y .. r. 111(4.
?. PLY}, Yk 1,,44 ...»..., . _.. ...57`,A.r .o- o •..