Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Permit B93-0455 - ROSIN RESIDENCE - ADDITION
City of 71,akwi& (206) 431-3670 Community Development / Public Works • 6300 Southcenter Boulevard, Suite 100 • Tukwila, Washington 98188 BUILDING PERMIT Permit No: B93 -0455 Type: B -BUILD Category: ASFR Address: 4936 S 114 ST Location: Parcel #: 334840 -1700 Zoning: R1.72 Type Const: V -N Gas /Elec: OIL Wetlands: Water: TUKWILA Contractor License No.: FATHESC158RL Status: ISSUED Issued: 12/23/1993 Expires: 06/21/1994 Type of Occupancy: DWELLING Slopes: Y Sewer: SEATTLE TENANT ROSIN ERWIN & JACKIE 4936 S 114 ST, TUKWILA, WA 98178 OWNER ROSIN ERWIN & JACQUELINE 4936 S 114TH ST, TUKWILA WA 98178 CONTACT SCOTT LAROSE 102 N.E. 50TH STREET, SEATTLE, WA 98105 CONTRACTOR FATHER & SON CONSTRUCTION CO. 102 N.E. 50TH STREET, SEATTLE, WA 98105 Phone: 206 725 -2430 Phone: 206 725 -2430 Phone: 206 547 -2040 Phone: 206 547 -2024 *****************************,************** * * * * * * * * * * * * * * * * * * ** * ** * * * * ** ** Permit Description: ADDITION TO EXISTING SINGLE - FAMILY RESIDENCE. SETBACKS Units: 001 Front: .0 Back: .0 Buildings: 001 Left: .0 Right: .0 Fire Protection: N/A UBC Edition: 1991 Valuation: 12,177.44 Total Permit Fee: 242.10 ******************************************* * * * * * * * * * * * * * * * * * * * * * * * * * * * * * ** o'Y • 13. _.3 - Date Permit Center Authorized Signature I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign for and obtain this bui ding permit. Signature: Date: 12--) 2.3 C3 Print Name: ‹:(- 5 Title: .aka?/2_ This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. All PERMITS ISSUED FOR NEW CONSTRUCTION, REMODELING, OR DEMOLITION PROJECTS REQUIRE CONSTRUCTION, DEMOLITION AND LANDCLEARING WASTE MATERIAL FROM THESE PROJECTS TO BE RECYCLED AT A KING COUNTY LICENSED OR APPROVED FACILITY, OR TAKEN TO REGIONAL DISPOSAL FACILITIES. CITY OF TUKWIL° Department of Community Development — Permit Center 6300 Southcenter Boulevard - #100, Tukwila, WA 98188 (206) 431 -3670 Building Permit Application Tracking PLAN CHECK NUMBER bq3-0455 PROJECT NAME rl DATE APPROVED SITE ADDRESS 140(0 � � IL( � SUITE NO._-- INSTRUCTIONS TO STAFF • Contacts with applicants or requests for information should be summarized in writing by staff so that the status of the project may be ascertained at any time. • Plan corrections shall be completed and approved prior to sending to the next department. • Any conditions or requirements for the permit shall be noted in the Sierra system or summarized concisely in the form of a formal letter or memo, which will be attached to the permit. • Please fill out your section of the tracking chart completely. Where information requested is not applicable, so note by using "N /A ", date and initial. DEPARTMENTAL REVIEW "X" in box indicates which departments need to review the project. DEPARTMENT DATE IN DATE APPROVED REQUIREMENTS / COMMENTS :1 BUILDING - initial review ��11' 613 t2 !�/i3 W (ROUTED) CONSULTANT: Date Sent - Date Approved - - -�� .FIRE ll_ /c/ ` 3 / 4//A FIRE PROTECTION: Sprinklers Detectors (� N/A FIRE DEPT. LETTER DATED: INSPECTOR: INIT: i4'1.4, BY: (init.) IBAR/LAND USE CONDITIONS? � �� No PLANNING m II. i�� !3 ./9.7 ZONING: 7 . REFERENCE FILE NOS.: E FILE INIT: J MINIMUM SETBACKS: N- 0 S. E- W- ;:;:ii. v PUBLIC WORKS IZ/In/R3P , O 3 UTILITY PERMITS REQUIRED? Yes f No PUBLIC WORKS LETTER DATED: A2 .2.40 93 INIT: ,!1y.." C OTHER dor INIT: BUILDING - final review / t2 /w/q3 IZIC.1 GJ , TYPE 'OFCONSTRUCTION: V14 CERT. OF OCCUPANCY? (]Yes `J No UBC EDITION (year): i99 1 . 44' d INIT �,�� ' BUILDING OFFICIAL P g ' :3 INIT: ■:'�% REVIEW COMPLETED AMOUNT OWING: , $14CM0 CONTACTED - C" �� �� e DATE NOTIFIED t a! c 1'-" v n-___ J BY: (init.) - -�� 2nd NOTIFICATION BY: (Init.) 3RD NOTIFICATION BY: (init.) 01 /oeres CITY OF UKWIi_A Department of Community Development - Building Division 6300 Southcenter Boulevard, Tukwila WA 98188 (206) 431-3670 BUILDIG PERMIT APPLICATION PLAN CHECK NUMBER - Ott ESOP! PT! ON: >.i. BUILDINWERMITE EE: PL AN.:CHECK:FcE:::: ?'> DUILUING :SURCHARGE ® }�DA'TE;` SITE AD PRO ECT RESS SUITE # q_% S . t l4-rh VALUE OF CONSTRUCTION - $ 1Q_,, i .--n . Li LI ME /r4't- rE 5 ( N ASSESSOR pr 4D4O``l 00 -o .r TYPE OF i New Building I.,, Addition enant Improovemen WORK: 0 Rack Storaae II Reroof 1...) Remodel (residential) (commercial) ., Demolition (building) Li Other: DESCRIBE WORK TO BE DONE: 1g`. -�'' ) o . . o r 9Nldvg 57412 AbbrN1 BUILDING USE (office, warehouse, etc.) , I2 i b rv'n/G -(_J NATURE OF BUSINESS: WILL THERE BE A CHANGE IN USE? No 0 Yes If Yes, new building requirements may need to be met. Please explaii SQUARE FOOTAGE - Building: Tenant Space: Area of Construction: 07 , 5 5-F WILL THERE BE STORAGE OR USE OF FLAMMABLE, COMBUSTIBLE OR HAZARDOUS MATERIALS IN THE BUILDING? O No C Yes IF YES, EXPLAIN: • PROPERTY OWNER �L,�✓r.. -0-,,z)(..( e- r24,5 (J PHONE -72,5 yit 30 ADDRESS ,j I (4 -N„ 6-E ZIP :I7g CONTRACTOR a C-9-,--15-7 Go 4.42-,J PHONE 4-i 2v D ADrs j (2 2 NE 9 ST- SA-TI„; wi ZIP ,c;ip.5 4004 rWA. ST. CONTRACTOR'S LICENSE# FAT 1-1-e-560 15S� EXP. DATE of ct't 7 24o ARCHITECT (2,5lGr`1E (2.) 5 G. --rt' LArz,)S - Fk lfvY2- S�rJ C-44 r4, PHONE 5 :DRESS s�ra�,E --- ZIP :IfEfiEB;Y <,CER� IF;Y :TN. BE -:TRUE 14D`;CORREC'I" tlD :ANd ;FXAMIN;`I?;,Tf• 4'GlON; ;;ANA KN BUILDING OWNER (� SIGNATURE DATE OR S co 2- NC AUTHORIZED PRINT NAME AGENT (ADDRESS CONTACT PERSON 5` PHONE 5 0Il-f _ICITYfZUP 5 cA(( t q�(o� PHONE? APPLICATION SUBMITTAL In order to ensure that your application Is accepted for plan review, please make sure to fill out the application completely and follow the plan submittal checklist on the reverse side of this form. Handouts are available at the Building counter which provide more detailed information on application and plan submittal requirements. Application and plans must be complete in order to be accepted for plan review. VALUATION OF CONSTRUCTION Valuation for new construction and additions are calculated by the Department of Community Development prior to application submittal. Contact the Permit Coordinator at 431 -3670 prior to submitting application. In all cases, a valuation amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Building Division to comply with current fee schedules. BUILDING OWNER i AUTHORIZED AGENT If the applicant is other than the owner, registered architect/engineer, or contract° licensed by the State of Washington, a notarized letter from the property owner authorizing the agent to submit this permit application and obtain the permit will be required as part of this submittal. EXPIRATION OF PLAN REVIEW Applications for which no permit is issued within 180 days following the date of application shy expire by limitations. The building official may extend the time for action by the applicant for a period not exceeding 181 days upon written request by the applicant as defined in Section 304(d) of the Uniform Building Code (current edition). No application shall be extended more than once. If you have any questions about our process or plan submittal requirements. please contact the Department of Community Development Building Division at 431 -3670. DATE APPLICATION ACCEPTED DATE APPLICATION EXPIRES Il TIP _ imq yi DeParunent of Labor &Industries Contractor Registration Suction PO Box 44450 Olympia WA 983044410 FAX TRANSMITTAL SHEET TO: - z.ETy FROM: 1(/VOAget-- `. TIME: '7, DATE: [2.--?..2_ q3 # PAGE + COVER 1 102 NE BOTH ST SEATTLE, WA 9810E PHONE: 206 -647 -2024 FAX: 206 - 547 -1326 REGISTRATION VERIFICATION. l ` —t„ YrP t� t.�Y...: _1.1- .. /.c� '� 4 - .. o . . Olympia ,„ * tare el Win tt 'nor .......C,.,, :)Staele he n C .o.. �..-e,�......... l'-' 5 C� Contractor: ' Your Certificate of Registration will be sent from the Olympia a should be received within 2 to 3 weeks, Please keep this record until o receive your Certificate of Registradon, y r (206) 9464226 SCAN 3(10.5226 PAX (206) 9364221 F625.036.000 registration verification 4 -93 trod Ie tt T'9n 62C 9e :ON "151 7fsats4 you W) i iH001 VEQ at= : k? T 311 26 . - i c -D3Q CITY ofCE1TuxvnLA1 DEC 2 2 1993 PERMIT CENTER kk *k** * * *A* * *A * * * * * *.* * ** * * * * *** A4 * *4* *k ** * *k * ** *k * * * * ** * ** * *k ** CITY OF 1'UKWIL.A, WA. TRANSMIT * 4** k***** k**' k4*** kkk• k* k********** * ** **k* *A* * ****4 *** * *k4**k4*4k TRANSMIT Number.: 93001690 Amount: 93.00 11/17/M/400328 00328 Permit No: 893 -0455 Type.: B -BUILD BUILDING PERKIr Parcel No: 334840 -1700 Site Address: 4936 S 114 ST Payment Method: CHECK Natation: LORENZEN WORKS Tait: SLB *********** 4lv*******k*** k* k****** ** * * * ** * * * ** * * * * ** * *k ** *k *k *4 ** Account Code Description Paid 000/343.830 PLAN CHECK - RES 93.00 Total (This Payment); 93.00 Total Fees: Total All Payments: Balance: 242.10 93,00 149.10 'GENERA TOTAL CHECK( CHANGE 6364A000 93.00 93.00 93.00 0.00 15 :40 tk ** ****A•***** * k**** kh* A** hA* 1** kkf• k* kk •kkkkrkA*k•A•kh•k4•*k****A **ftk CITY OF TUKWILA, WA TRANSMIT ** ***** h******• h• k**•• k*****Ah***** k, 4k** Ak•kh *•h *k*kk•kk****Ak•kk * *kkkk TRANSMIT. Number: 93001834 Amount: 149.10 12/23/93 09 :43 Permit No: 093-045; Type: 0• -BUILD BUILDING PERMIT Parcel No: 334840 -1.700 Site Address: 4936 S 114 ST 12/27/ Payment Method :. CHECK Notation: LORENZEN WORKS 3 :nit: JLU *•kk•k *•k*** ****** A * ** k *** * *k•kkk•A* •****k ** ********* *kk•k kA•* ******* k* k Account Code • Description • 000/322.100 BUILDING - RES 000/345.830. PLAN CHECK RES 000 /386.904 STATE BUILDING SURCHARGE total (This Payment): Total Fees: Total All Payments: Balance: 242.10 242.10 .00 Paid 144.00 .G0 4.50 149.10 GENERA GENERA GENERA TOTAL. CHECK 144.00 0.60 4.50 149.10 149.10 CHANGE 0.00 7352A000 14 :47 CITY OF TUKWILA Address: 4936 S 114 ST Permit No: B93 -0455 Tenant: ROSIN ERWIN & JACKIE Status: ISSUED Type: B -BUILD Applied: 11/17/1993 Parcel #: 334840-1700 Issued: 12/23/1993 **'k' * * * * *k* k* * * * ** k * * * * * * * * * * * * * *A* k * * *'k * ** * *•k* **•k * *-A k•k* * *'k k * *'k 'k'k.* ** *•k ** k'k k* Permit Conditions: _ 1. 1. TEMPORARY EROSION CO TROD .MES•IURES SHALL BE IMPLEMENTED AS NECESSARY TO PREVENT:' dFF `= STTE` "SED-IME ,TATION. 2. PERMANENT ERO ;ON.: CONTROL MEASURE SHALE' °BC 'IN;,,PLACE AS SOON AS POSSIBLE" " AFT„ER�: FINAL GRADING HAS BEEN�1COMPLETED AND PRIOR 'l FINALI PROEclq / CCEPTA,NCE . §',„1,,41 `� 5,� , 2.. No changes , ' :l l be made .o the plans iin l es'" appro,vedR,,bl?: ,the Tu0;w1 1a B l iding Di,.viision. ;;,.v,,, , • r, „.,,� ur ;,q #: ',,'': 3. Plumbin `' '`t g �.�'�r�m ;�t`�'s,hall be�sobta�ined througlir�Ghe S�at- k ^ir�1�a County Dep�artme,nt``zfof Public ,He`op. Plumbing wish Abe ,4 4� inw ect�e, by that agency, including' all gas piping`''' ,,,”' (296-02 22) t ' s +' ;�' ( N 4 . E l ec Oi,�ta 1;,,I,permi t sha l ,b'e obtained through the Wash iti9s�t;on �i State'Divi,sion tof Labor and Thdustri,es and all electrira,lft wor r i i l T bep inspected by.._tllat1 agency (248.6630) r, 4 5: All`'jerm'1dt §,;,1 i #ospectionA,,record , andda pproved plans shall be ma iirip r Y �.�.. «. ..: f n � � �` 1-{ � �y'r 't e+' t 4U ( ' a an �oonstr ctlon:_ The e• d •. mart are o be; maintained t iq 1' �f i n a �l --ifns p e ion app , o a vl, ,..i. g k�t'i '' av� ;�1ab�l:,e��,, n ranted. , All ' ood o. remai_, In p,i•ac'ed`.'concr'ete1s,ha`l °l the treated woody Not1i4`1' .:t City of Ttikwi to Bui lding`i`i,yision prior tv g any concrete,./ This pr o edu.rre'a .ss:' In.wadd i t i on "to• a IP pl reg t, emet for special . inspect,1p ,E , 0 A 1 1 c'pst,ruc�tion to be done i.n cAnf ,o matnce with approved plan nd� •r qfu i rements of the Un i�tonm BL l l d iCode, (1,,9;91'' Edit to as amended by the Washington . 8�;' t B ld�,ig Co "d.e,, rat �,,:�a. �Y`'�`.•. �, b Uni.for i Mechanical'�Code (1991 Ed ti6n) i n Was,hJngton Sta Energy o "de (1‘99�1m S'e:cond Editio ). �'s`F��srw.�. 4 1.. INSPECTION RECORb C: Retain a copy with permit CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 PERMIT No. - (206).,431 -3670 ro ecl7©Cr) — ice h Y ype o ns r� ) Address: 3 /N.44— . e Called* 1_. 2,7 Special Ins' las: /' 30 Date Wanted: Requester: Phone No.: Approved per applicable codes. ❑ Corrections required prior to approval. COMMENTS: Inspect Date: ❑ $30.00 REINSPECTIO FEE REQUIRED. Prior to reinspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Recept No.: Vale; 0 INSPECTION RECORD Retain a copy with permit CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 PERMIT NO. (206) 431 -3670 Approved per applicable codes. COMMENTS: ' ❑ Corrections required prior to approval. [tom"'_ Date :2 7 3 ❑ $30.00 REINSPECTION FEE REQUIRED. Prior to reinspection, fee must be paid at 6300 Southoenter'Blvd., Suite 100. Call to schedule reinspection. Receipt No.: Dade: ,..�....n.... �.. .. _.... • - - j`-''I wet Address: 4 I �l 1= Date Calved: .. -� a--G 47....m strut • -. 1.:,e "anted: , c, " G 40 p.m. Requester: j'aLicl Q Phone No.: Q5_ a t o Approved per applicable codes. COMMENTS: ' ❑ Corrections required prior to approval. [tom"'_ Date :2 7 3 ❑ $30.00 REINSPECTION FEE REQUIRED. Prior to reinspection, fee must be paid at 6300 Southoenter'Blvd., Suite 100. Call to schedule reinspection. Receipt No.: Dade: ,..�....n.... �.. .. _.... • - - INSPECTION RECORD 0 Retain a copy with permit CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206) 431 -3670 •�.: I`K.stin Addilion ''pe T415 1cei-1c Address :4cl% 5 (14th Si—. ''"1l mewed: a- 15— / 1 Special Instructions: Date Wanted; o?. /6 -q ..m. Request er.- -Gckie 05i� Phone No. :lay •1)-1f36 Approved per applicable codes. ❑ Corrections required prior to approval. COMMENTS: 4,7q o /;34-/-- , Ci4na NA, eypa-z.‘e.4 Inspector: / c Date: A. 4 �. /..L ALAN L ❑ $30.00 REINSPECTION FEE REQUIRED. Prior to reinspection, fee must be pald'a 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. INSPECTION RECORD() Retain a copy with permit CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 PERMrr Nt0 / (206) 431 -3670 Project: v.. /� / Q�.C,K t.)' Typeoflnspection: C(v( f/1 — Address: 1 �Lo) 1 c.i �, Oats Calved: �4 L `� C Special Instructions: late wanted: -- 1 5 -R am. p.m. (wiz__ Pfwne No Vic: 14- l (n ` L...., ❑ Appro ved pe r appl icable codes. Corrections require —oval. COMMENTS: I l ,, `e ❑ $30.00 REINSPECTION FEE REQUIRED. Prior to relnspection, tee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. o: INSPECTION.' RECORD 0 Retain a copy with permit CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 L3 PERMIT N0. (206) 431 -3670 Project: �,,,� / S/r 1,-i Type of inspection: < v4 %7 e,i, Address: zrer, 3 G 5o //47,..,4 Date Called: /(2_, y,,,... Special Instructions: Date Wanted: Requester, Phase No.: Approved per appilcable codes. ❑ Corrections required prior to approval. COMMENTS: ale) ./ vh d g-.. S /A% �/ ❑ $30.00 REINSPEC ION FEE REQUIRED. Prior to reinspection, fee must be paid at 6300 Southcenter Blvd,, Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 "Project: Type of Inspection: Address: 4 . 5:;. by 0, e .:.: / "�'7 `'rf Spada! Instructions: ' Date Wanted: �� / � ` "'.2— j fl .m. Requester: Phone No.: oved per appble codes. O Corrections required prior to approval. COMMENTS: Inspector 0 $30.00 REINSPECTION FEE REQUIRED. Prior to reinspection, tee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspectton. Receipt No.: i)ate: INSPECTION RECORD Retain a copy with permit CITY OF TUKWILA BUILDING DIVISION 6300 Southcerrter Blvd., #100, Tukwila, WA 98188 (206) 431 -3670 ro y ge) i � Type ion: F `4 Address: co / �l 5' / / ( ` t Date Called: Ca led: Special Instruct Ions: Date Wanted: i , �t �, i` am. p.m� Requester: D Phone No.: '4-7 - Z 0 ek) 0 Approved per applicable codes. Corrections required prior to approval. COMMENTS: • / 771 `4 G(f PAC/► S ,oe_ "ice 041 iiaJ / e..1. l 6074.7- tZet,2, r-lee, A- y y ,z ,�• .60 ) ) ©l c/G'j A.r,H /C— ~ 001-7 C/r/?.L/721 +, . '4Ji / � of € • 17.e, t..0,- �/ ed.,*A -e.," G /e= rs^!.4, / -.S 1-...- r.,...-, / l _5ni S14—,— G. 4471 !--40 J7 4-4-s9 z,,..., / C (�4* C - Cr // 9 3/-3‘74 ik-y ,-,76,1- h lh� .I �c � � rh 0 o`er ' I.,. • O $30.00 REINSPECTION FEE REQUIRED. Prior to reinspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. DATE CITY OF TUKWILA 6300 SOUTHCENTER BOULEVARD TUKWILA, WA 98188 * * REVISI ;� N SUB 1TTAL �zOr' PROJECT NAME RoSi RECEIVED CITY OF TUKWILA JAN 2 6 1994 PERMIT CENTER ADDRESS % f3 S -- //V S CONTACT PERSON c /_„Yf!/(% C712 ,tgo /S6 b�PHONE $ y 7- 2 0 WI ARCHITECT OR ENGINEER �a PLAN CHECK/PERMIT NUMBER /?73 D V5 5 TYPE OF REVISION: ���n3 a6IdkkaAeLP SHEET NUMBER(S) "Cloud" or highlight all areas of revisions and date revisions. SUBMI'1"1'ED TO:. f50,_b ,e,elioacri4e4 c r, Celotex Blackore-)Tkia&IAX Foil•Faced Foam Sheathing oVe-11-. 7.t Feig- Unfacecl Glass Fiber Batt 15 Exterior Siding 16\,uIA\ BASIC WALLS WITH SIDING DI 13/2"4-1 71-1-Cr2m,o( ra (3 Paabi-INS g- 1 Foundation Wall 4 P\GR.P4\ oF ATWAt4 ,--- Fott- I NJ L-AT ( 0 Minimum 1/2" Gypsum Board Polyethylene Vapor Retarder 2-X4 p 16`10c. gp iriP‘11,o1(-6113.-rrz 7A6fie2s.B, 16t P‘e-• ceo NGL.fr-S t>' 1/16" 007 -71P:ew.-r- i ALAN\ 5.4 Di t.) 6, ti (1 G TtN 9 E-)11:a 15.'051 ailt7A 44\11, VARAZ. P'ARRor 0 0 tf (3) /4 fel S Gl2e6NED 0,r) t \ 12JDG5 oF APN) BASIC WALLS WITH SIDING 01A-6 O -L B(Lau N6 Minimum 112" Gypsum Board Polyethylene Vapor Retarder ZX1 I *Fv P �16roc 7/16" ost3 270 2x9i m q►� uF I Er & �il�chs v "cL , 7A6 :1°5B, t54 c-orv►C' evoINGLt✓S I-12- ,a 16fro G 12A -era of L a-Kt <T 4 raor 2�8oF2 0,65 as-3 1,..t;t: tf-1 I6A NAIL-Q. I? "oc SimPSor'l vZ NArIGst`..; OF TUKWILA PPROVED 4AN 2 199/3 ,�E i►/I B1 ILiIN. D "ISION MIN I� r�ut.lt_ll�I�`�TI ,(mIL vlrlYl� VA( P.. F7Ag Q (PC(,.crJG WDVE of A G�GA►.t< rr :�I app �r (ti (3) 4 xI�e 4 c12 at) 110(eafrOc t= fit -air CITRECEIVED �UWILA JAN 261994 PERMIT CENTER To: Permits From: � John A. Pierog, PW Development Engoineer December 20, 1993 Date: Subject: Rosin Residence Addition 4936 South 114th Street Activity No. B93 -0455 Review Comments The subject project was reviewed at the December 14th Public Works plan review meeting. No Public Works permits will be required for this project. Temporary erosion control measures shall be imple- mented as necessary to prevent off -site sedimentation. This condi- tion has been entered into the Sierra Permit System. If you have any questions concerning the above, please let me know. JAP /jap cf: City Utilities Inspector Development File City of Tukwila Jan 04, 1995 Department of Community Development SCOTT LAROSE 102 N.E. 50TH STREET SEATTLE, WA 98105 RE: ROSIN ERWIN & JACKIE Dear Permit Holder: John W. Rants, Mayor Rick Beeler, Director Our records indicate that on Feb 04, 1995, one hundred and eighty days will have passed with no inspections having been called for under Tukwila Building Permit Number-B93-0455. Unless you call for an inspection, or obtain a written extension from the Tukwila Building Official prior to that date, your above referenced permit will become null and void on Feb 04, 1995. If your project has been completed please call for final. If you are actively working on it please notify our office. If you have any questions or need further information to obtain an extension on your permit, please call the Tukwila Building Divison at 431 -3670. Sincerely, y is Osby Ac ing Permit Coordinator Department of Community Development 6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • (206) 431-3670 • Fax (206) 431-3665 City of Tukwila John W. Rants, Mayor Department of Community Development Rick Beeler, Director August 8, 1994 Mrs. Jackie Rosin 4936 S 114th St. Tukwila, WA 98188 Dear Mrs. Rosin, Re: Your Extension Request for Tukwila Building Permit #B93 -0455 A 180 day extension to the above reference permit is hereby granted. Rationale for granting this extension is that there has been no major code revisions adopted since the time your permit was approved and issued that would have any affect on your project. Please be advised this Is the only extension that will be granted for this permit. If substantial work is not started on this project by February 4, 1995, Permit #B93 -0455 will become null and void on that date. If you should have any further questions on this subject please feel free to call the Permit Center at 431 -3670: Sincerely, ne 1 Building Officla 6300 Southcenter Boulevard, Sulte #100 Tukwila, Washington 98188 • (206) 4313670 Fax (206) 4313665 TO: Duane Griffin, Building Official Due to circumstance's beyond our control my husband and 1 are presently unemployed, and therefore cannot afford to complete our remodeling project by August 23, and receive our final inspection. We would like an extension on our job through November or December until we can.get financially secure enough to afford toy. purchase insulation and a fan /light for our bathroom. Thank you for your consideration in this matter. Sincerely, otli.(„11 '2e4L1.1 RECEIVED AUG i 51994 ,.;OMMUNlTY DEVELOPMENT Jackie Rosin P.S. Our permit # is B93 -0455 Jul 06, 1994 City of Tukwila John W. Rants, Mayor Department of Community Development Rick Beeler, Director SCOTT LAROSE 102 N.E. 50TH STREET SEATTLE, WA 98105 RE: ROSIN ERWIN & JACKIE Dear Permit Holder: Qqr xvcorda S. d?.catca that on Aug 22, 1994r wig hundred and eighty days will have passed with no inspections having been called for under Tukwila Building Permit Numbers ;2.93-,0455'" Unless you call for an inspection, or obtain a written extension from the Tukwila Building Official prior to that date, your above referenced permit will become null and void on Aug 22, 1994. If your project has been completed please call for final. If you are actively working on it please notify our office. If you have any questions or need further information to obtain an extension on your permit, please call the Tukwila Building Divison at 431 -3670. Sincerely, Shellie Bates /Sylvia Osby Permit Technicians Department of Community Development IIIIMMIIMMINI101•11111■1•1101111■11M AMMO 6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • (206) 4313670 • Fax (206) 4313665 FILE CO I . . . 1 lydderatand that tho Pita' Chp A ;rt -r 43 c a aut$ct to orrora and oric:.lon,'ct) r...- *;a!1of gm does not shod s the vtola pon 1 cl any I adopted code or ordnance" Riotlpt, of pgnflatw s aop�► of appolvwd plans edmowli god. •1 _44440 ca Oata1 rL'2-3 jqj . N& 011 r 1 • I 1 ♦„ ••• 1•• ..• • ,.,.•, , 1.. . 1 . 1 1 1 11111111 1 1 11111f11 NIPARATE MIOUIRED Fa D MECHANICAL ELECT- a 1 $PLUME:NQ D GAh r ?1!110 1 crry or 71 switA EPUILDING E,.II1aIoN ! 1111 1 ! 1 1 1 1 1 1 1 t,4610 : I %Q } t� 1 I AN.. 1 1 1 1 1 ,, ! i 1 1 1 . 1 . I.66AL: ; L917,$55 I(d ! , ('!: N1W.MANS GD 'M t o-r1 •1- oP' 1 isv15t, pf KG I *HotT! fl4tI No orplN[> ftoHijposQ!i. col 5D : PLA-r - BV4 1 !4 a �D : N��ttI�,MA 1 Jh�:A opv;) '1 1 1 1 1 1 1 1!, 1 1 cdry o�°dcwua NOV 17,193 1 maw Oman 111tfr 1 1 1 : 1 1 1 1 1 1 1 1 1 1 ! I ' ' I f 1 1 1 $ 1 1 I I I is 1 1 1 1 1 1 11,1t11111110 1111 1 1 1 t H 1 X111''11' 1' 1 1 • 1 1 1 1 1 1 1 or • • • • • EAST ELE\lAT 1 ON q on •1 i LJ • • 1.• 1 • I • I 1 1. 1 inn • 1 • } I ' I • , • r • 31 1 1 I 1 i 1 'I 1 1 1 ! • • 1 ' I I 1 • NI 1 • I X .3 '1 .1 • P!'- Gam,( •Zi•A Trams 1 I 1 1 I 1• • 3 • 11111 ADp'N I • • t. I 3 I 1 1 1 31 • 1 I 1 1 1,,, 1 1 1, 1 1$ . 1' I � 1 I 1 t • 1 3 ,, 1 1 1 , 1 1 RQQF ; ,•FRAME I NG PLA V44 1 " 1 � 1 3 1 1 1• 3 1 1 • 1 • 1 • CITY OF TUKWILA , APPROVED DEC 1993 0 M I 1 • I. 1 4 1 1 i 1 I 1 1 t 1 1 1 I 1 I 1 , ' ' I 11 I 1 1 I 1 t 1 I 1 1 , 1 I; 1 I 1 I I 1 1 1 111 11 I 1 1 ! , 1 , I 1• 1 1 1 1 1 I; 1 3 I 3 • I 1 I I 1 • I 1 1 1 3 1 I I 1 1 1 1 1 1 1 1 , 1 1 4 1 1 1 1 1 1 • 1 1 3 1 ' 1 1 1 1 1 1 1 1 , 1 1 1 0 . ; I : I I 1 1 1 .1 13;.•, 1 1 1 I I I I I t l I l t 1 1 I , I • 1 '• 1 • 1 1 I Vi�.1 .1 3 1 I 1 1 I I I 11 1 1 , 1• 10EIVED 1 ' C FF' KWILj� 1 1 I ■ 1 1 ,( 1 1 1 1 1 1 I� ; I 1 1 1 1 1 1 NAM 1 I t • 1 , , • 1111.1,,; 1 ; 1 1n 1 1 1 1 I i 1 1 1 1 i 1 1 , 1 1 I I I I I 1 1 ! I ' 1 , 1 1 1 1 I I t 1 l 1 1 i i 1 1 I i l l IN ' D VISION I • 1 • • • 3; I I • X� C� Flt' GRAD , 1 11111 I • ' 1 • 1 1 1 1; 1 1 1 1 1 1 1 I', I•;. NQSTH ELEVATIQN 1 1 ! i • • YEN ''1 t , I I Z O • 8 vs .0 o I , � 1 I f I I . ris ♦/� IS krnV•' 4.M U. tr. 1 1 1 1 1 1 1 11,111'1111!11 1 1' 1 I I I 1 1 I 1 1 1 It 11'1 1 1 t i 1 t 1 1 I 1 1 ! • III 1 1 . 1 I 1 1 III 1 . 1 1 1 3 1 1 1, 1 1 1. II!,, 1 1!! 1 11 1 I! ! 1 1•i I' I! 1 1 1 • 1 ' 1 (4) S';t 2oov g 1 1 Roof 1 2 )44 -rtwss ss "pG 1/16"093 / 19* miser *no, o_ 101061•55 Iti lopiPeraCtS4G 1 9/44,08%x' @ o tr51 *ROY t41 erea aTEI2.1o(- wM,ts 1 Zx�NF2eI6ipL ibis m€'oSs ji4I vel•T AWM . 51DW11G Pr 2x6 I�F2 stw Jy 5(1 o" /w44. 8o 1.'r's 6 oG 1 mine cc / akit., r n9 1.• 44. ckl 6R" 74 le Qou(Ltb 1 GOho FDN &" yodel: no bn K .i Fib (2)ifekizeat0R. TeP Bar 1 frANtakAtialtrigi;0 ,• c.. st a8 •- Amite V INYt,� • v1N'n(Z 15RRR1o12 u NOM SLA5R '2 OT 1 o H ',6•■ c') if 4 ?WW2- -bP 0 igrataltst saL Po Rt - ID INS ARmua f me.-MR �Y49V ast rr (14 (14ft 4 BAacc'4r 1 • 0 0 • 1 V� tt 6' Got(, FDt1 WA%4 - *N' 'I'% 1 t" ceases, • C 'R% c2�# 4 RraM9 Ior4Fer • 4 • • • 1• • • .► • • ;. • S •." • j • . It -9 FPN PLAN •1 "4 " = I 0 0 1 1 Go•aL Fbt4 Wq-1r 55 NSW C.51-A7ANG .1 N 0 1 2s) 26446 MIk&ARD 5220 VINYL Vw(1/ CIA Detz% U •117 1 00 2265E 11 180 KYt -IM U. 50 • 3o.63F So. 05C16% 187.55E o— HEAT *0 Gtft of, sr a Nt -.vet IAEAtet SF 1 1 1 1 1 1 1 1( I I I I 1 1 FLo 1 1 1 1 1 1 1 1 1 1 1 . 1 1. 1. 1 1 1 1, 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1, 1 1 1 1 1 1 u f ,, on ale 1 1 1. 1 I It 11 1! 1 1, ,, 1 f I 1 1 1 1 1 . 1 1 1 1 1 1 1 1 1 1 1 1 1! 1 r • • U S E o `o. J W. iectorJ 502.2.2 1 • RECEIVED CITY OF TUKWILA NOV 17,1993 CITY. OF TUKWILA APPROVED I' DEC 1993 T 71111 DIN , DIVISION 1 411114 • • General: • Constriction shall comply with the latest addNbn o11he UBC. • Do not scale drawings. (Use dimensions) • Refer to' interior elevations for cabinet and counter lengths, dimensions, counter lop materials and detail reference. Verify AN exlsting dimensions before Installation. • Design Criteria: Dead bad Actual Floor the bad 40 psi Deck live bad 80 pal Stair live load 200 pal Roof live bad (Snow load ) 25 pal • Wind and earthquake: These bads vary depending on site location. Check wfth local structural engineer to verify compliance with lateral bads. • Assumed allowable soil pressure 2000 psf • Insulated double glazed glass at a1 exterior glass areas and tempered glass in all sliding glass doom and windows less than 10• above floor. (Check bcal codes for additional gluing requirements and also manufactumrs specification) Verily aN rough opening window sizes wfth window manufacturer. • • • 1 • • • KNchen range and bathroom exhaust fans shall be vented to the outside via metal ducts unless otherwise approved by the building official. Cblhes dryer shall be exhausted to the outside 1 in any area that is habitable or oontainkg other fuel burning appliances. • Every dwelling unit shah be provided with smoke detectors conforming to the UBC Standard no. 43.8. Detectors shah be mounted on the ceiling or wall at a point centrally boated in the corridor or area giving access to rooms used for steeping purposes. When steeping room are on an upper level, the detector shall be placed at the center of the ceiling directly above the stairway. AN detectors shall be boated in accordance wNh'approved manufacturers Instructions. When activated, the detector shaN provide an alarm in the dwelling unit. • Stairways: Maximum rise r minimum run r, Minimum headroom 8' r, rninki um width 3r handrail to have ends returned and placed minimum 3C, Maximum 3r above tread nosing, unless designated for the disabled, the handgrip ponlon of handrail shaft be not less than 1 1/4• nor more than 2• in cross section dimension or the shape comers. Handrail projecting from a wan shall have a space of not less than 11/2• between the wall and the handrail. Install lire blocking at top and bottom of stair nun. Useable space under stairs to be surfaced with 5/8• •Type •X• GWB, tape and finish gypsum wallboard. One hour construction. • Shower: Shown shoe be equipped with flow control devices to limit total flow to a maximum of 3 gpm per shower head. WSEC Sec. 423. Showers to have 8' r high minimum surround with water repellent GWB backing. All enclosers , to be safety glass. • Attic Ventilation: The net free ventilating area shaN be not less than 1/150 of the area of the space ventilated, except that the area may be 1/300, provided at least 50 percent of the required ventilating area is provided by ventilator boated in the upper portion of the space b be ventilated at least 3 feet above eaves or cornice vents with the balance of the required ventilation provided by eaves or cornice vents. Rafters spaces enclosed by ceilings directly applied to underside of rafters shell be sized to slow a minimum 1 inch clear vented air space above Mrinsulatbn. Attics with a maximum ironical dear height of less t than 3r need not be provided with amen opening. Per UBC code no. 3205. • Exterior Decks: When decks, porches. etc., are more than 30• above grade, provide guardrail not less than 3r high with kktennediate members not more than a• span (to withstand a horizontal force of 20 bs. per linear foot ). Provide mninaum 18• crawl space under wood. M • • • . - -r- •••••••.Me.e sasses e..• es. •• •.e . •�•• •• Foundations: • Footkgs to bear on solid undisturbed earth. ( Assumed soft bearing capacity to be 2.000 pet ). • Footings shall be placed at a depth to conform to local codes. • Concrete shell attain a minimum 28 day strength fc.2500 psi and mix shall contain not lea than 5 sacks of cement per cubic yard. • RsWorckg peel shall conform to ASTM specMkafbn A815.72. Grade 40. fy40,000 psi Design lb) 1t000 pal. Canaete protection (cover) for minfordng Shea be as follows: • Footings and other untamed surfaces, earth surfaces r • Formed surfaces Indirect contact **health r •Slabs and waIs (interior face) 1 • • • ReMlorcement shah be aauratey placed and adequately supported by concrete, metal, or other approved chairs, spacers, or ties, and secured against displacement doing concrete or grout placement. Tack welding not allowed. Except where shown otherwise on aurclural drawings, nkdorcement M concrete shoe have concrete cover as follows: • Concrete deposited againe earth Formed concrete against earth &odor laces of walls Web faces d walls To lop of elllbs•onsade Wood: • lawn brnberoaloulstbne are based on Douglas Fir- Larch, except as shown sIh mbe on drawInge, 'aided in accordance with Standard Grading Aube of WWNA or Null No. 9 d WCW, a isiows: WM ds•NeF p and bWier( Partite ki s and Pins- No. I and Sy r r W4• 314• • • • • •.•• •• •• • • • . • .• w•• •• • r•••••• • G!fleral Specifications --Wood Continued: Beams and Stringers-Dense No. 1 and better Posts and Timbers-Dense No. 1 and better • • AN 2• lumber shah be seasoned to 19% maximum moisture content . AN wood In contact wNh concrete, masonry, or soN shall be pleasure treated per UBC Standard 25.12. • Glued•laminated members shall be Douglas Fk•Larch or equal, conforming with ANSI /AITC A190.1.1983. Grade combination 622P unless otherwise specified on drawings. • All plywood shall be identified by grade mark of an approved inspection agency and shaft be Standard C•0 Flat Interior with ext. glue unless otherwise specified on drawings. Plywood exposed to weather shaft be (minimum ) CC Exterior. Framing Members: • It may become necessary to Increase depth o1 framing memben to accommodate thicker insulation materials than that shown on drawings. • Top plates shaN be doubled on an stud walls. Cripples under headers shall be continuous to sole plats Block a0 stud wafts as required for sheathing. Blocking, 2• wide of equal depth of the members, shall be provided between aN joists and rafters *Moir supports, unless members art nailed ba rim pis! • Beams, girders, and joists supporting bearing walla or other concentrated bads, shaft not be notched. Joists, except as above. may be notched no deeper flan 1/4 the depth, at top edge only, provided such notch is located withkl 1/8 to 1/4 of span from lace of support. Sawcuts for notches shan not overrun depth of notch. Holes in joists, beans, and girders shaft not be larger in diameter than 1/10 the depth of member and shaft be located within center hall of the span. AN holes shah be centered within depth of member. Holes and notches in studs sheets located within 1/3 of height from either top or bottom but not closer than r from plates. Holes and notches in studs shall not exceed r in diameter or depth. Studs in exterior walls shall not be notched. • Joists, rafters, and decking shaft not be cut and headed or displaced to provide for openings in tools or floors, except as detailed on drawings. • Install all horizontal members with crown up. • AN members in bearing shah be accurately cut and aligned so that IuN bearing is provided without use of shims. Bearing posts shaft have IuN blocking or support under. Ail rafters shall be notched for full bearing at all supports. All joists shaN have a minimum o11 i/r bearing on wood or metal supports. Lapping • Ledgers and stud waft foundation siN phis shaN be bolted to concrete rowith anchor bolls of size and minimum spacing as shown on drawkgs. At least two bolts shaft be provided for each piece with one boll within 12• of each end. • All plywood waN sheathing shah be applied as follows: Center vertical pints over studs and center horizontal pint over r blocking or plate. Nall top of panels to double top plate, and neN bottom of panels to ancored sill plate. Apply gypsum board so that end pints of adjacent courses do not occur over the same stud. • Plywood sub-floor and roof sheathing: Install with lace grain at right angles to supports, continuous over two (2) or more spans. Allow minimum space 1/18 - inch between end joints and 1/8-inch at edge jokes for expansion and contraction of panels. Underlayment: • UnderlaymeM shah be installed in accordance with this code and as recommended by manufacturer. Lay underlayment on 18 Rosin sized sheathing paper. Particleboard floor undertayment shell conlonn to Type 144 grades of UBC Standard No. 25.25. Underlayment shell be not less than 1/4- k+ch in thickness and shell be • identified by grade made of an approved inspection agency. • 1/4• to 1/26 thick: 8d common or 1 1/2• Rig shank nails 8• o/e 411 edges and 8• o/c each way M field. 5•86 to 3/46 Chide ed common or 1 'Mining shank nails 8• o% edges and 8• odic each way in field. Nailing: • Minimum nailing requirements for standard connections unless specifically shown or noted 'Shemin. Automatic nailing or stapling devices shah • not be used without prior approval of method and fastener by owner. Xem IMIds Toe nail to plates, MN or gkder • To parallel demote joists Ai laps over bearing, taw nil End Buda nai to plates Or toe nee 2 lath. std! Spike together Laps 1 Intersections, face nal To e la IIad To jolpb lash tide _.P!toe id, • • _• ..... • ••••• • • lie_ er lied maw 3 3 3 2 • d from It 4 M a4. M • Ni• el nail bnY y . ed led led led ed lb Id liid Nailing Continued: T� obe naN to joists, each end Studs Comer, angle, or muNiple r x laminated beams or inter Spice together Dist• joists or.headers Spice together, along each. edge Plywood sheathing and sub-floor nailing At edges of each sheet • v. • • be. er et el nails Bha el mull box =MOO At interior of each sheet • 2 24•o/c 18• o/c 18'oic 3/8• thk 8d fir It 5/r thk 10d 8d 8• o/c max. 8• o/c max. space nails 10• o/c for 3/8' and 1/r thick plywood • Sheathing shaft be nailed as follows, except where shown olhowisr Roof plywood: 8d common at r o/c at all supported edges and at l r o/c at interior supports. Floor plywood: 8d common at r oft al all supported edges and at 10• o/c at interior 10• o% at aN Interior studs. Wall plywood sheathing direct to framing: l0d common at r o/c all panel edges and at 10• o/c at an interior studs. • Anchor all studs at door openings, ends, and comers of walls which are • sheathed with plywood and/or gypsum board to bottom plate with 2 Simpson A45 framing anchors. AN manufactured connection hardware shall be as designated on drawings and installed and fun nailed in conformance to manufacturer's instructbns and applicable ICBO approvals. Trusses: • Prefabricated wood trusses shall be designed by the manufacturer for the spans and conditions shown on the plans. A loading shall be as follows: Top chord Loads 25 pal Top chord dead loads 15 psi Bottom chord dead bad 10 p 1 Total Load 50 pal • (exceptions: Tile roof bad to be 55 psf) • • Wood trusses shall utiNze approved connector plates (garrgnail or equal) furnish shop drawings and design calculations (complete with stress diagrams) for approval prior to fabrication. Submitted documents shaft bear the stamp of a registered professional engineer provide for shapes, bearing points, hip framing, etc., shown on the drawings. Provide for all temporary and rmanent truss bracing and bridging. Truss shall carry manufacturers stamp. Contractor shaft have design details and drawings on site for frame inspection. No truss shall be field modified without prior approval of the !wilding department. Gypsum Wallboard: • Provide gypsum walboard of type and thickness indicated on drawings. Gypsum board work and materials shall meet all requirements of ANSI No. A 97.1, br the •AppNcatbn and finishing o1 wallboard.' Joint compound system mixed, applied, and finished in compliance with manufacturer's printed directions: to be invisible after finished, ktcuding all metal comer beads 8 trim.• • Gypsum walboard on stud walls: cooler nails at r o/c a1 studs, plates, and blacking use 5d nails with 1/r wallboard and Id nails with sir unless othenvlse shown on drawings. Building Felt: • Cover surfaces behind siding, shingles, and where Indicated on drawings with asphat saturated, non- peiorated, lei without wrinkles or buckles. Lap horizontal joints 3•, r at vertical joins, and carry into openings, up walls ir and down sides r minimum. Locate end laps at Nast ir Mom Internal and external corners. • • Infiltration Control: • Exterior jokes around windows and door frames, openings between walls and loundatbns• between walla and roof and between walls and panels; openkgs at penetrations of utility services through walls, Itodr, and roofs; and all other such openings in the building envelope, ktckrdktg access panels into unheated spaces, shaN be Sealed, caulked. gasketed, or weatherstrlpped to NmN air leakage. Al exterior doors, other than lire-rated doors, shaN be designed to limit air leakage around their perimeter when In a dosed posnbn. • Doors between residence and garage are not oonsldered lire -rated and must meet the above requkeme rot• AN exterior windows shin be designed to omit inteatlon into or from the bulldog envelopes which shah be substsnllNed by testktg to Standard ASTM E 28343. UNe•bulit and millwork shop•made wooded sash ars exempt from testing but shall be weatherstrlpped, caulked and made lightly felkp. WSEC Sec. 501 (e). Vapor NarrterslGround Covers: _ • nMNr spaces termed where sling w�applied directip to the underside ol the roof nein Ind M SerherwaNs• • kIss MspNd baits with a perm nag his than one may be Ire ss II eta vapor it to the warm side• SWAN are nei mete than l Itches on and geps bMween the lasirfr andMta uhs not linseed Me Irish. • • •• •• • •••• •• • Vapor BarrlereiGround Cover continued: • A ground cover of s mN. moon polyethylene or equivalent shall be bid over the ground in all crawl spaces, The ground cover shaN be overlapped one foot at each joIM and shall extend to the foundation wan. WSEC Sec. 402 Heating: • Each dwelling unit shall be provided with heating facilities capable of maintaining 70 F at a point of 3' above the floor in aN habitable rooms when the outside temperature is as set forth In Sect. 304 WSEC. Sect. 1211, U.B.C. • AN warm alr furnaces shall be listed and labeled by an approved agency and installed to listed specilicatbns, Sea 504, U.M.C. • No warm air humace shall be installed In a room used or designed to be used ss a bedroom, bathroom, closet or M any inclosed space with access only through such room or space, except direct vent furnaces and electric healing furnaces Sect. 704, U.M.C. • No warm air furnace shall be installed in a closet or alcove less than 12• wider than the lurnace or furnaces Installed thereln wnh a minimum clear woddng space less than 3• along the sides, back and top of furnace. Sect. 704, U.M.C. • Heating and cooing equipment located in a garage and which generates a glow, spark or Name capable of igniting flammable vapors shall be installed with the pilots and burners or heating elements and switches at least ir above the floor level. Sect. 508, U.M.C. • • warm-air furnace installations in attics or crawl spaces shah comply with Sect. Toe and 709.U.M.c. • • Every appliance designed to be vented shall be connected to a venting system complying with Sections 9•A and 9•B, U.M.C. • Every factory-built chimney, Type L vent, Type B gas vent or Type BW gas vent shan be installed in accordance wnh the terns of Ns Nsting, manufacturers instructions and the applicable provisions of chapter 9, U.M.C. • Vent connectors shall be installed within the space or area in which the appliance b located and she11 be connected to a chimney or vent in such a manner as to maintain the clearance to combustibles per Table No. 5•c, U.M.C. Ductwork: • Dud systems shah be of metal as set font in Tables Nos. 10•A,10.8 and 10•C or factorymade air ducts complying wfth lr.M.C. Std. No. 10.1 U.M.0 • Joints and seams shall be substantially airtight, Sect 1002 (c), Table No. 10-A ( rectangular ducts ) and Table No.10•B ( Flat, oval and round ducts ), U.M.0 • InstaNation of ducts shaN comply with Sect• 1004, U.M.C. • Duct ksulatbn shall be Installed M accordance wfth WSEC Table 418 .• Water Heaters: • Water heaters are required to meet ASHRAE Standard 90A•80 or 1987 NAECA and are labeled as such. In addition, electric water heaters installed in unheated spaces shaN be placed on a non•compresstble surface or floor ksulatid to a minimum of R•10. WSEC Sec. 420. '" ' • s , • • Woodstoves/Fireplaces: • Stall be provided with: tightly-Ming flue dampers, operated with a readily accessible manual or approved automatic control; An outside source for combustion air of 8 square inches in area and shall be provided with a readily operable damper, • Other solid fuel-burning appliances shaN be provided with combustion air ducted dingy to the appliance per Manufacturer's specifications. WSEC Sec. 411. • • •-- •-- .••_•_ ._•...._ .. • •. • • • 1395-4)4 CITY RECEIVED WILA • NOV 17 1993 PENA! wean tt# ,. - ...._.... • r 1 1 DESIGN SHEET NUMBER A• • • OF