Permit No: B93 -0475
Type: B -BUILD
Category: NCOM
Address: 9404 EAST MARGINAL WY S
Location:
Parcel #: 332404 -9019
Zoning: M2
Type Const: II 1 -HR
Gas /Elec:
Wetlands:
Water: SEATTLE
Contractor License No.:
TENANT
OWNER
CONTACT
Status: ISSUED
Issued: 01/14/1994
Expires: 07/13/1994
Suite:
Type of Occupancy: WAREHOUSE
Slopes: N
Sewer: SEATTLE
MUSEUM OF FLIGHT
9404 EAST MARGINAL WY S, TUKWILA, WA 981084097
MUSEUM OF FLIGHT FOUNDATIO
9404 E MARGINAL WAY S, 07024 -00, SEATTLE WA 98108
FENTON KRAFT Phone: 206 764 -5700
9404 EAST MARGINAL WAY SOUTH, SEATTLE, WA 981084097
*************,***************************,** * * * * * * * * * * * * * * * * * ** * * * * * * * * * * **
Permit Description:
CONSTRUCT A NEW CMU BUILDING TO HOUSE NEW NATURAL
GAS FIRED BOILERS. BUILDING IS SEPARATE FROM
EXISTING STRUCTURE AND IS ATTACHED TO AN EXISTING
CONCRETE RETAINING WALL.
Units: 001
Buildings: 001
Fire Protection: DETECTORS
UBC Edition: 1991
Front:
Left:
SETBACKS
.0 Back: .0
.0 Right: .0
Valuation:
Total Permit Fee:
5,026.34
138.15
******************************************* * * * * * * * * * * * * * * * * * * * * * * * * * * * * * **
Permit Center Authorized Signature
�_�
Dat`eL -!-"I-
.
I hereby certify that I have read and examined this permit and know the
same to be true and correct. All provisions of law and ordinances
governing this work will be complied with, whether specified herein or not.
The granting of this permit does not presume to give authority to violate
or cancel the provisions of any other state or local laws regulating
construction or the performance of work. I am authorized to sign for and
obtain this building pe mi .
Signature: 1/A171, J
Date: gtit-4,( i11 1994/
Print Name: Feti 'IoN 14.ch
Title:_L /VLC 1"JQitupgtr
This permit shall become null and void if the work is not commenced within
180 days from the date of issuance, or if the work is suspended or
abandoned for a period of 180 days from the last inspection.
All PERMITS ISSUED FOR NEW CONSTRUCTION, REMODELING, OR DEMOLITION PROJECTS
REQUIRE CONSTRUCTION, DEMOLITION AND LANDCLEARING WASTE MATERIAL FROM THESE
PROJECTS TO BE RECYCLED AT A KING COUNTY LICENSED OR APPROVED FACILITY,
OR TAKEN TO REGIONAL DISPOSAL FACILITIES.
CITY OF TUKWIlit
Department of Colimunity Development — Permit Center
6300 Southcenter Boulevard - #100, Tukwila, WA 98188
(206) 431 -3670
Building Permit Application Tracking
PLAN CHECK
NUMBER
ff15- 04-6
PROJECT NAME
SITE ADDRESS
SUITE NO.
INSTRUCTIONS TO STAFF
® Contacts with applicants or requests for information should be summarized in writing by staff so
that the status of the project may be ascertained at any time.
• Plan corrections shall be completed and approved prior to sending to the next department.
• Any conditions or requirements for the permit shall be noted in the Sierra system or summarized
concisely in the form of a formal letter or memo, which will be attached to the permit.
• Please fill out your section of the tracking chart completely. Where information requested is not
applicable, so note by using "N /A ", date and initial.
DEPARTMENTAL REVIEW
"X" in box indicates which departments need to review the project.
DEPARTMENT
ATE;
BUILDING -
initial review
31 FIRE
10.-14-13
APPROVED
I -( -94 R.
ROUTED
IC (0 /61Y
INIT:
OUIREMENTS ! COMMENTS
CONSULTANT: Date Sent -
Date Approved -
FIRE PROTECTION: • Sprinklers
`yy
BAR/LAND USE CONDITIONS? ■ Yes
FIRE DEPT. LETTER DATED:
• PLANNING
N
12-45-
A'J
INIT: v�
ZONING:
Detectors
INSPECTOR:
N/A
REFERENCE FILE NOS.:
MINIMUM SETBACKS: N-
• PUBLIC
WORKS
INIT:
S- E-
UTILITY PERMITS REQUIRED? (IYes No
PUBLIC WORKS LETTER DATED:
BUILDING -
final review
BUILDING
OFFICIAL
1-/t- ?4
INIT: i d4
INIT:
TYPE OF CONSTRUCTION:
CERT. OF OCCUPANCY?
°Yes grjo
UBC EDITION (year):
199
REVIEW COMPLETED
AMOUNT
OWING:
6
CONTACTED
�n
DATE NOTIFIED
�'
11 ��
YI
BY;
(init.)
�� (�
J
2nd NOTIFICATION
BY:
(init.)
3RD NOTIFICATION
BY:
init.)
01/08/93
CITY OF TUKWILA
Department of Community Development - Building
6300 Southcenter Boulevard, Tukwila WA 98188
(206) 431 -3670
PLAN CHECK
NUMBER
UILDR3 PERMIT
APPtJCATION •
Division
DESCRIPTION
AMOUNT
BUILDING PERMIT FEE .
PLAN CHECK FEE:
BUILDING SURCHARC?°
X80
RCPT #
DATE
OTHER:
TOTAL -
SITE ADDRESS SUITE #
;1"/'0'f kusf Kill `Ji „,tI L fay 5Oklit
VALUE OF CONSTRUCTION - $
7000,
PROJECT NAMErTENANT
MvsZvtil or FL) or T1
RETRoF/t)
ASSESSOR ACCOUNT #
ASSESSOR
33Z g Ohl — 901) -,90
(commercial) Demolition (building)
0 Other:
TYPE OF New Building CT-Addition 0 Tenant Improvement
WORK: Rack Storage O Reroof 0 Remodel (residential)
DESCRIBE WORK TO BE DONE: Cowrraua A nrik, Cl'1V Bwu.onvt. To Novs,F Maw AJATuR,4L GAS FRL'p So/wRs
MI /5 SE'PFM1 FROM g-Xlsvive. 17RUc..7VRE MP is AUTATOIED ro by ex/sr,tv6 (oucpe7 k� 4/Nru.
LALL
BUILDING USE (office, warehouse, etc.)
NATURE OF BUSINESS: AVIAT1OJ MusEUr►
WILL THERE BE A CHANGE IN USE? LJ No O Yes If Yes, new building requirements may need to be met. Please explain:
SQUARE FOOTAGE - Building :IE66 -z Tenant Space: Area of Construction: 2'112
WILL THERE BE STORAGE OR USE OF FLAMMABLE, COMBUSTIBLE OR HAZARDOUS MATERIALS IN THE BUILDING?
0 No C6 Yes IF YES, EXPLAIN: W4TURAL GA Film) 13o/LtR5 mLL t/riL, it e. Fuel. FOR litrtiritivAt 6.0113 usT,O,J
/(/d c7TM R S7-OR/i(,E OR Vst, v P F. /4NIW I.r:
FIRE PROTECTION FEATURES: 0 Sprinklers gl Automatic Fire Alarm System //AM R/4/.5
PROPERTY OWNER jMUSEUt1 or FL1Grfr 1'ouNbjtrtav 1PHONE70..r700
ADDRESS 9' Ensr MARGINAL WAY Sovrki SEAT (l.E WA
ZIP25.IQ$ -_ ct U .97
CONTRACTOR
Ver 70Aptrr vinvyl.)
PHONE
ADDRESS
ZIP
WA. ST. CONTRACTOR'S LICENSE #
EXP. DATE
ARCHITECT vv ARCH EGTS (I l v>1?)A Awl o 6grzc,
PHONE 422_ 699a
ADDRESS 12T/ rsj D ,bw Juc *1200 SE nirz,e VA izip9g,'01
I HEREBY .:CERTIF.Y :THAT I..HA1rE READ:ANU: EXAMINED THIS APPL;ICATION.,0.ND'14NOWTHF S.' E TP
BE TRUE AND CORRECT, AND:t AMAUTHORIZED TO'APPLY FOR:!TI-1tS::PERMIi . :'
BUILDING OWNER
OR
AUTHORIZED
AGENT
SIGNATURE f� -G K.
DATE
PRINT NAME I PNTOrkJ i AFT
PHONE 76L1 -570o
ADDRESS J11.11 SFL( phsr/'1ARfs)NAL, WAY SOVrN
CITY/ZIP Sekr..�r 9SIog
CONTACT PERSON FFIV7.0, kgA r
PHONE 70..5-700 rr V6(-07
APPLICATION SUBMITTAL In order to ensure that your application is accepted for plan review, please make sure to MI out the
application completely and follow the plan submittal checklist on the reverse side of this form. Handouts are available at
the Building counter which provide more detailed information on application and plan submittal requirements.
Application and plans must be complete in order to be accepted for plan review.
VALUATION OF CONSTRUCTION Valuation for new construction and additions are calculated by the Department of
Community Development prior to application submittal. Contact the Permit Coordinator at 431 -3670 prior to submitting
application. In all cases, a valuation amount should be entered by the applicant. This figure will be reviewed and is
subject to possible revision by the Building Division to comply with current fee schedules.
BUILDING OWNER / AUTHORIZED AGENT if the applicant is other than the owner, registered architect/engineer, or contractor
licensed by the State of Washington, a notarized letter from the property owner authorizing the agent to submit this
permit application and obtain the permit will be required as part of this submittal.
EXPIRATION OF PLAN REVIEW Applications for which no permit is issued within 180 days following the date of application shall
expire by limitations. The building official may extend the time for action by the applicant for a period not exceeding 180
days upon written request by the applicant as defined in Section 304(d) of the Uniform Building Code (current edition).
No application shall be extended more than once.
if you have any questions about our process or plan submittal requirements, please
contact the Department of Community Development Building Division at 431 -3670.
DATE APPLICATION ACCEPTED
1Q—itst-013
DATE APPLICATION EXPIRES
COMMERCIAL
SUEiMITTAL CHECKLIST
711177010.7011■7
NEW COMMERCIAL BUILDINGS/ADDITIONS
L I Completed building permit application (ono for' eactl struct70)
Assessor ACCOunt Number •
Two sets (2) of tho following Spocifications
•01.11•0111101■1•1■11111111/1•1118.0•10•11•41111.111.1•11110111•77
0.1110•0111■10■110
.COMMERCIAL TENANT IMPROVEMENTS
ComPle‘d building permlt npptication (one for oath structure er
— Soils report atarriPed.bje.kWashington:Statelicenaeciengineet...:•:••:::-:::;'.
....„
•.:
17:1 Topographical survey
1[.1"EriergY Calculations stamped by:a:Wathington,Stato::licenSed.::::•!::::::::,::::•-
.•--; engineer or ....................................................
. .
Workitig
arcliitect,•which
• • SilElPlail..• . .
•• Arcilitectural drawings
Structural drawinq
• -.!•Mechanical•draWinda::;::•:•::.':::"......"".
• • . Lan jacapci"plail
L_.J Carriploted utility permit application (ono for. entiro•Project)..:::;;
(6) sets of oiii dr,swings
ti/QT E: ,C'ae inilily pGritiit'thp;ilica:icin and checklist for.qpcifit: ut,I,ty •••:.
.
cifr,70t01 requiromor:tq.. •.• • •. ...:..: •••
RACK 0 (0 1.
I
ssi.U.,serAr,count1`1.14111 bijr " E.' •
T,P:ie (2) seld'Of
Ccirgpleted tuiidi,iq perrnit apriliCation1ene:tot::o•a&vsicitir e)." . .
1■a'saasof:Aocciirit .
]:..tgarrative".rieStribirig'ekisting'ioof,::rriaterial being rrnovod and
material being installed,
. „ . ........
ANT1.:141‘ikISATFILIT.E,DISI-1..,:u. .. . .• : . :
•; i F;i/ildiag floor plan:06,?irig: .... : : :.:::::. •i ...::::::::::..i.,.....::::: ::::::...:i „::,..,:::: :.: : ": :: • : - •• •
'-- • ' : ' ' : ; ::: : •.. • : l: ...-• :: .:. .: ' ' :' ......: - i •:::.."--.• •.' : :',::::::. . :
err. , . .. . ..."•,. :,., : .. ; ...:.. :.:;:::.;. ::: . . -::'::: :•". . . .
:',77.7"...•.:..C.. o:: n' p.: le:•te::. d b:: i.:" ild': i n g p• ornit•ap•::::pl ica t o•::: n EItirc pico ih1 cWill beloCatod
Exit doors ' - '.. ': : ::: : :::' : : '.: 'I I. ::" : :: i:::::: i':::::: 1,•:.'::::::::.":" ". ", —1 Asseas.or ACCountflUrnt?er:"......,:::.:::::: :. ..:::::,:••::•,:::::::.,::::.:,:
• : •:Dimoatilon of Eill .'iisies ;.1::::•••::::::::. :: -.....• . ii.•:, ..,,:. ...:„.....,......:...:.-: .:,,:::::, :,: : ...::. . :. ,.....,,, ,,.:
..., ,.:. ,...
[J onant !Tad° fleorlphit ahoiAing rack sioragefriyikii;-aiales:andi •
NOTE: Include dithen•sions of racks (height w dth ancliength) aiIo •
,:kal exit ;wry:: on plan. ' • I . . • • • • -• • "... '.:•• •
i 1 '..,.:;r0:::•tural Calculations staniped by a Washington
riginsar (rack atorago 3..and ;;;;;. •
•
RSDENTtAL
. .
• • ; _" •• -: • ••• RESIDENTIAL; REMODELS„
DI/Ittl.L(t4c.i:.;!ApuirloNs:
... •••.; . .
. • •,...,..:;:..,.... : ".• , ,, ; , - '.: ..... . .:: ;: , :, ., ,', .„,... : :', . . .. • ....;... ... . ..:: , ..,........ .,....,... , . ,„.,., . , ,
...... . . . .,. .
.....••,.- .......:.:::......,:::::::.:....,....:
. .
...
Cl -..Completed
.•.........:..... bUiding .p er M. • . ita.. „ pp•, ••.i• :l•Oati:.:Oni ':.(' :.O....:.i:- n:...:....„eife:.” :..- ..r....:'.. 'i. . f.. . .:..:...,..a :..::• ., ...." ..:.:h. .: .:: .. '. : •:::a.:,:.::„....i.,:..r,:.....:.::k :•..;•:.•...•.•.•.:, :::•,..:•.'.::r::•..:7::
E:1%i3Ospor:Acbbunt•Nuin or :-:.• . . :.".::•'•. - ::::::::.. -••:. : ::„::.,.. .:..'
:.:...
:• .
.: .
.....
i----T.T 12Y sets of Warking:.draWinga;"..Whiot)'laellide.::-!:'
::.":"'-:.:::".:::.•!•..:::::',.".:Sitefplart••,•:::::::::•::::::?::',"::::::.:•,........• •-•••••.::::.::,:::::.":,i....
.. ,. . „.
.,...:•;::.,::::......;.;::::::::,:::•.:.FoOndatiori:••plqn.:.::!:::•::::- • . . .
::::::::::••••::::::!:"•!:::::?'::::.•::Flabf:'plati'!::::::::":::!''''';:::".•
Root 0:14n:::::::':::,.:•::".:::::•::....,.......
••"••:""'"'":::•::::'::::::•••::BIJildirig:.Oliii/atletia:'.(all•i•Yietiia)
;:•:!':::.::::::::::::::::::::::::!:::Buileing.cross7.aecpop..:::::::::.:::::•:::.i::::
:'‘.:::::::::::::::::•:i:::::::::g.:::.StiiJ:,•iiii-al: framingliplans......
"•• :•••::::::::::.,::::,ii....:::::,:"..:::.,... . ....,:ii::::::"::::....::".?..::::::i'..;:::::.:::::::.„-:::::..:::::'::::::::::::..";"::......
fp,tc:Yi 0..1(e.ipv. utility:: yorklO''iii0.0i?'60:f.r.900::P1111tjibertyyl. yiiicgtioiii:::::::'
.. ... .. .. , .
:......piid pOri.../r) 0 'q t, be tiObalit1...944 ...,,:.:,;,..! . ::::::::::.'",....,`::::',...,...::".i.;; ...:. ::::::,;,.....;.;::;.:: .. ?,::.....:,,...:■';':■,■••?liO■ii.:::'''''''...:;1.,:'',:;"'::.:::::::' i:.:'.:.:.
.....:'..,:::....:;',.....,..%;i:**.f.::: i''''i, .....::".:',....:.:.1...%....,:: ...!, .'!:.''''',::. 7:7 7...7.:1'.7 77 :: 7.'7: '7, .7.,. ,..: 7. . ' 7..77 :77:777 • :77 : 7: . .
, CoMploied cuilding
• . ,
permit application :Cone for each stru
. • . . ••..• :
[] L.iqal (1,,scliptian -.• • .. • :•• . .
-: - - - • - ...." "".
1---.1 As;:esseri\Cociuntllutr!bo/.i.'„::::-"•,:i ...:':',:...: ':';''':::::: !•::"::••:::::::-• ""'""...":"•::::-'•;:-•:::- •!: -..i.: ..••• ::: ''
i_.....J.:.,• 7......••......• •..... ...i..;:ii•-•...: •••_. ,.......•;..i.:;:::...:::::....:::::....-. .,......H,;:.,;;;........:,...•....... •
, • '':"..i.l.'"•:....[1::::" . .
[] TAito:soia(2).6i.tti,orking driviriga;:::•wl-:11Cli"inclUdo.;......i:i...i::::::.::::;•;:::::::::::::•;:::::::',..":::::•••.....f...::::::
77: .., • ::: , ...'17 7... 7:7: 7.77....,.7 7 .7:. 7 7.7.7.:
. ' 7 • :. ,I::, . • 7,: 7 .
7ilta.P14r1. 777 "....—....4-'..(61,•p• iiir;;;:ih17...iiiii4::siii.i4iriiii:t.k•i•i:aiir,....,....,::::--..: •ii,....:
. . . .
. ..
Fottndation::plan::::-:::, ......:::,::•••::::"Incliide access to.,5i..:11iiing,Shov400.....::...:::::„ ......,
l'....: -..• ..........i.:::::::::•:....F199:Pl0!1,.•••..",::..•••••'":::::::::::.': .:;::"....".;: i''.:..:::::::;..:1.:.;•:::. ..•::;%,.iiittiS Id 10;11,;(1.! c(
.! '..;::•,...:..:...;•...',8g0f..0.1.e.:. . . . ....:•,..;•:.i.,....,,,.• ::',...,!....,..•:.•".:.••••::::•••:1,.•:::,...;•••::•••.‘... . :•:.;•.::::. • . :.:::::.;:r.:::•":::'.....::::,,••••••:"::.••••••••.:•••••••:..... •'••••••••• "••::::::: ;;.•-.•
• • ....±,......::::•••:.::.••:.::::::',,,,bi:ileling•!Cle■iaiiOna....,(alf•i.pii.iWs).:. "...:"..!!,••:,.::::'•.:•:'"!••••"...:.....:••••••,:::::::::,":•••:::::.::':::::::..":::-.:i.:::,::::::: ' ::
• - . . ' :"'....:••:::::::::-. • -
••••.:::::::::::,.i:7::',..131)110lg:creaaap:.P.ctioi)::::,••:.',•::::'.:',".::'::..:::::::':'::::,:.::::•':'..-•:::::::':.::'::::.••:.::•:•:' "• :: ••:•;•.:•..:•:: .:
: .• -...-•• .-..iiucturr,1 fratnirig:plans
,.....
• • ' • : .• • .
••
• • • • •• ,•:••••..• . . . .
• . .. . ......, .•
(6) ••.soti.of site piotis showing .;; utiItios . . ,
: --- ::-:::::,."::::::•::::.:::i:::::::::'.....::';'::!":.:. . :. . ":.•':.'" ::.''''-! ...::'. • "" - ' ' -11,7.iiiii be cori:hnle:-..::..) ..-..":.
.•': •'•-•••• • Cif "ilie•elail,and utiltly.sitgp .
1.10.T.E:; Bt4. II •-.P9:•• ' - and che-idist..fo:TipP.Onc.:* T1:*•.::...::::"....: :-...'::::.::::::•••••'...:.:.:. •
te itatitit.dreineo:s..•.
licaton.an . ,' .... ••••,. •-•'. .-:.::: ,.. .... . .. , ., . iiniquo
• . ' :•• ' • ' :•':::' '• . ••:•"'' ..... '''''...:•:' . ' . • . and soils irito-i:itieti6ii,iilalbfi."1.a TI" 9P ::-. . • . ::.:,::
• site Conditipl#.•'..........,...:...,......,...i..::: - ....,.., ...... . . , . .. ,..
. .
MUSEUM OF FLIGHT
January 14, 1994
Project: Museum of Flight Boiler Retrofit
To :, City of Tukwila Building Department
The Museum of Flight will be acting as the general contractor of this
project. All construction and material purchases shall be done by the Museum
of Flight staff, with the exception of the concrete block work. A masonry
subcontractor with a current Washington State contractors license will be
selected to construct the concrete block portion of the building. Please let us
know if any further information or documentation is required.
Sincerely,
Fenton Kraft
HVAC Manager
Museum of Flight
9404 East Marginal Way South • Seattle, Washington • 98108
Telephone (206)764.5700 • Facsimile; (206)764.5707
RECEIVED
CITY OF TUKWIIA
JAN 1 4 1994
PERMIT CENTER
F* h******* k*****• k* h* A**• k**• kk******** *h * ** * * * * ** *A *•k * *k * *k*. *k***•k
.CITY OF TUKWILA, WA TRANSMIT
1**************• k***** k.******** k* k* A*** **A•* *k *k•k. *k **•k * ****** * *k* **
TRANSMIT Number: 93001780. Amount: 138.15 12/14/93 15 :30
Permit No: 893-0475 Type:: B -BUILD BUILDING PERMIT
Parcel No: 332404 -901.9
Site Address: 9404 EAST MARGINAL WY S 12/15/93
Payment .Method: CHECK. Notation: FENTON KRAFT SLB
*• ***********.****** ****** *k* * * * * * *k**** * * ** **•k **k *fir * *k* ** * * ** *k*
Account Code Description :
000/322.100 BUILDING • -• NONRES
00.0/345.830 PLAN CHECK - NONRES
000 /386.904 STATE BUILDING SURCHARGE
Total (This Payment):
Total Fees:
Total All Payments:
Balance:
135.15
138.15
.00
Paid
81.00'
52.65
4.30
],38.15
GENERA
GENERA
GENERA
TOTAL
CHECK
CHANGE
7092A000
81.00,
52.65
4.50 ,.
138.15
138.15
0.00
14:49
CITY OF TUKWILA
Address: 9404 EAST MARGINAL WY S Permit No: 893-0475
Suite:
Tenant: MUSEUM OF FLIGHT Status: ISSUED
Type: B-BUILD Applied: 12/14/1993
Parcel #: 332404-9019 Issued: 01/14/1994
**A*********************************************k*********************kk***
Permit Conditions:
"''S 'iiii
1. No changes will be made,to:;thi pfih
. ; , unless approved by the
Architect and the Tuk044a-BuildingDTvlsiOn
2. Plumbing permit sjialyASe obtained through tleattle-King
County Departme*Of Pubil,dHealth;1Plumb,ing WiWpse
inspected by. ;that agehey'fric]Lidtng all gesfliipin
(296-4722)
3. Electrlca.1 ,shallbeoolatalhed:throu,gh'i'hOiashii4t*
State DiA4sloW6*, Labor,and Industries and all electrical
work wqpbee'Insp4Cted'by th'at\44ripy (248-6610).'
4. All me,Ohpnical Wbrk.Shalt bp.:under:saparate permit -thrOugh
the C.lty of Tukwila'
..
5. All RO=Mitsi insp'ectioK.,;recor4s,and approved plans shall' be
maint44n0,4Vail'able at the job site prior to the start of
any/OOnstru8tion. TheSe-docOents are to be maintat,ned
avalyOlelAmti) finalinspect0On approval is granted:, -.:--- *
'
1 4 6
6. When, s;special inspection 15 the owner,
architect air engineer --sh4g*tifhtrtbkwila Building
DiOionmof appointlienetofth'e inspection agencies prlorAo, 1 ,
theWrstOuildiAg' inspection., C015166,Of'all special,,,.
ini4pte0,0relS,ortSifia41/ Vesiimietdd..4o the Building, ,
DivMon ih;a,timeTy4460r: ROor4,,,s1-411-contain address,
prolked,tmpe, permit number and type ',0f fil0e_ation beinig,
‘..
performed. ft.,.
7 The *OkcialCihsei'ector •
shall submitfa'f'itYi'i, -ilgiied report q0i
statt4001hOh'er tile work requiritig spec:1,0 tnsOectlon Was„
to theA:lest of the6, j nspectors knOWle'dgi,\iii OCtifOrmance with
,
approveCplansand specifications and tha„applAbablework
tei, A
manship NerlovisiOhs of the UBC. r,
tt-1,
8. All strudtural 'OOhcrete shall be special, inSpectecr
, ; .
•j,' Sec,,,,,,.,/,,,../ 4\
O6
(a) 1 UBC) rl ,, ),, ., . ,4
,••'„V,V.,.,,
9. All structural welding shall be done Oy W.A.B.O. cer,i,fied
-A, ,.-..,,,--,.,,E;I:.
welder and spis.00., inspectedcw ,1(a) 5 UBC),,../
10. Bolts installealoncreteiSh41;Ab4MOcial insO4ted (Sec.
306 (a) 2 UBC). '''*i,i- ' '---' ,,-3
11. All structural niasonry per UBC
Sec. 306 (a) 7
---.----,
12. All construction to be done in Conformance with approved
plans and requirements of the Uniform Building Code (1991
Edition) as amended by the Washington State Building Code,
Uniform Mechanical Code (1991 Edition), and Washington State
Energy Code (1991 Second Edition).
13. Validity of Permit. The issuance of a permit or approval of
• plans, specifications and computations shall not be con-
strued to be a permit for, or an approval of, any violation
of any of the provisions of this code or of any other
ordinance of the Jurisdiction. No permit presuming to give
authority or violate or cancel the provisions of this code
shall be valid.
s
City of fukwila
FIRE DEPARTMENT
444 Andover Park East
Tukwila, Washington 98188 -7661
(206) 575 -4404
Fire Department Review
Control #B93 -0475
(512)
John W. Rants, Mayor
January 10, 1994
Re: Museum of Flight - 9404 East Marginal Way South
Dear Sir:
The attached set of building plans have been reviewed by
The Fire Prevention Bureau and are acceptable with the
following concerns:
1. The total number of fire extinguishers required for
your establishment is calculated at one extinguisher for
each 3000 sq. ft. of area. The extinguisher(s) should be
of the "All Purpose" (2A, 10B:C) dry chemical type. Travel
distance to any fire extinguisher must be 75' or less.
(NFPA 10, 3 -1.1)
Extinguishers shall be installed on the hangers or in
the brackets supplied, mounted in cabinets, or set on
shelves (NFPA 10, 1- 6.9),,and shall be installed so
that the top of the extinguisher is not more than 5
feet above the floor. (NFPA 10, 1 -6.9)
Extinguishers shall be located so as to be in plain
view (if at all possible), or if not in plain view,
they shall be identified with a sign stating, "Fire
Extinguisher ", with an arrow pointing to the unit.
(NFPA 10, 1 -6.3) (UFC 10.505A)
Clear access to fire extinguishers is required at all
times. They may not be hidden or obstructed. (NFPA
10, 1 -6.5)
2. Exit doors shall be openaple from the inside without
the use of a key or any special- knowledge or effort. Exit
doors shall not be locked, chained, bolted, barred, latched
or otherwise rendered unusable. All locking devices shall
be of an approved type. (UFC 12.106(c))
City of ukwila
FIRE DEPARTMENT
444 Andover Park East
Tukwila, Washington 98188 -7661
(206) 575 -4404
Page number 2
John W. Rants, Mayor
Obstructions, including storage, shall not be placed
in the required width of an exit, except projections
as permitted by the Building Code. Exits shall not be
obstructed in any manner and shall remain free of any
material or matter where its presence would obstruct
or render the exit hazardous. (UFC 12.1O4(a))
Dead bolts are not allowed on auxiliary exit doors
unless the dead bolt is automatically retracted when
the door handle is engaged from inside the tenant
space.
Exit hardware and marking shall meet the requirements
of the Uniform Fire Code. (UFC 12.106- 12.111),
3. An approved fire alarm system is required per City
Ordinance #1646. An approved automatic sprinkler system
may be installed in lieu of a fire alarm system. (Plans
must be submitted to the Fire Prevention Bureau for
approval prior to installation.) (NFPA 72- 2 -5.5)
Call the Tukwila Fire Department at 575 -4404 for
approval of any system shut down. Have job site
address, name and the Tukwila Fire Department Job
Number available to confirm shut down approval. (City
. Ordinance #1646)
4. All electrical work and equipment shall conform
strictly to the standards of The National Electrical Code.
(NFPA 70)
5. Required fire resistive construction, including
occupancy separations, area separation walls, exterior
walls due to location on property, fire resistive
requirements based on type of construction, draft stop
partitions and roof coverings shall be maintained as
specified in the Building Code and Fire Code and shall be
properly repaired, restored or replaced when damaged,
altered, breached, penetrated, removed or improperly
installed. (UFC 10.601)
'
•
City of fukwila
FIRE DEPARTMENT
444 Andover Park East
Tukwila, Washington 98188 -7661
(206) 575 -4404
Page number 3
John W. Rants, Mayor
This review limited to speculative tenant space only -
special fire permits may be necessary depending on
detailed description of intended use.
Any overlooked hazardous condition and /or violation of the
adopted Fire or Building Codes does not imply approval of
such condition or violation.
Yours truly,
The Tukwila Fire Prevention Bureau
cc: T.F.D. file
ncd
City of Tukwila
Fire Department
411, r v
TUKWILA FIRE DEPARTMENT
FINAL APPROVAL FORM
Project Name, 114VStci kit O f f f I5 lrfr
?.k >vT�.yt�3tl ^� ^•� �xs,•:_m;t /,'.�' �S'4�Mf1�
John W. Rants, Mayor
Thomas P. Keefe, Fin? Chief
Permit No. 13 °% 3 -
Address 99Q 6-43- M /jiMt 1 Wy Suite #
Retain current inspection schedule
Needs.shift inspection,
X Approved without correction notice
Approved with . correction notice issued
Sprinklers:
Fire Alarm:
Hood & Duct:
Halon:
Monitor:
Pre -Fire:
Permits:
fieo 11 $i/
Authorized ignature
FINALAPP.FRM
Date
T.F.D. Form F.P. 85
Headquarters Station: 444 Andover Park East • Tukwila, Washington 98188 . Phone: (206) 575 -4404. • Fax (206) 575 -4439
INSPECTION RECORD C
Retain a copy with permit
CITY OF TUKWILA BUILDING DIVISION
6300 Southcenter Blvd., #100, Tukwila, WA 98188
PERMIT NO.
L206) 431 -3670
Project :t�S��vn 0(t �C,N i
Type of Inspect t.iA�i"
—"'
Address: ci go
e- �t ��
Date Called:
Special Instructions:
Date Wanted: )
2
am._
Requester: 1"14 I
Phone No.: 7 G e.` 5700
Approved per applicable codes.
❑ Corrections required prior to approval.
COMMENTS:
Inspector:
❑ $30.00 REINSPECTION FEE REQUIRED. Prior to reinspection, fee must be paid at
6300 Southcenter Bivd,, Suite 100. Cali to schedule reinspection.
INSPECTION RECORD
" Retain a copy with permit
CITY OF TUKWILA BUILDING DIVISION
6300 Southcenter Blvd., #100, Tukwila, WA 98188
(206) 431 -3670
r :
fit&t
m a F
J� -faNT
ype o
G I4/5
Address:
r1G
Date Called:
, Pi-
Special Instructions:
Y
/ 0
6- H--
Date wanted: S— /3 -9 71
a.m. p.m,
Requester:
J
Wro 1
Phone No; 70 (/ - 5760
Approved per applicable codes.
COMMENTS:
❑ Corrections required prior to approval.
Inspector:
Me:
❑ $30.00 REINSPECTION F E REQUIRED. Prior to reinspection, fee must be paid at
6300 Southcenter Blvd., Sulte 100. Call to schedule reinspection.
Fr",7o.:
INSPECTION RECORD C6 c13 —
Retain a copy with permit L 7
RTMff N✓
. /
(206) 431 -367 0
CITY OF TUKWILA BUILDING DIVISION
6300 Southcenter Blvd., #100, Tukwila, WA 98188
r. t to L4 M1
i 0
ype o ns, :. ions (2,w4A j . I
At 5'4-f M
M)
)
e CaHed:
,,.' a,3 --'it'
Sp edel Instructions:
Date Wanted
—a 4-- qi-l- am. p.m.
Requester.
r
Phone No_ ._
l 5 ___L(2_,,....
Approved per applicable codes.
❑ Corrections required prior to approval. ,
COMMENTS:
Inspect
❑ $30.00 REINSPECTIO EE REQUIRED. Prior to relnspection, fee must be paid at
6300 Southcenter Blvd., Suite 100. CaII to schedule reinspection.
lReceipt No.:
-bate:
0 INSPECTION RECORD
Retain a copy with permit
CITY OF TUKWILA BUILDING DIVISION
6300 Southcenter Blvd., #100, Tukwila, WA 98188
(206) 431 -3670
r0ec—,C���--- C
rimAs —i.k Yeti or. 1 L( „ �� 1 —
C
1ypB0 n
r
/V�
ni
Address:
cq ■IDLI F • Vhs_ w -
Date Called:
Special Instructions:
Date Wanted:
-3 1194
am
rr
Requester,
Phone No.:
Approved per applicable codes.
COMMENTS:
❑ Corrections required prior to approval.
Vt NT1 LA-R o •
Inspector:
❑ $30.00 REINSPECTION FEE REQUIRED. Prior to reinspection, fee must be paid at
6300 Southcenter Blvd., Suite 100. Call to schedule reinspection.
INSPECTION, .RECORD 0
Retain a copy with permit
CITY OF TUKWILA BUILDING DIVISION
6300 Southceriter Blvd., #100, Tukwila, WA 98188
1353
•
PERPIi N0./
(206) 431 -3670
•r, :«:
..
O.:. .,
/
' .1 rasa:
--_ L .. .
I ,, :.?t +►•*
n
stmt.,
60, &t.
:' C-4,
frElks ---
Date anted:
Requester.
Ph" `,:
t
�+
O Approved per applicable codes.
COMMENTS:
ICorrections required prior to approval.
k?0, /os.
,0 c
ism 1,4s G 74- /al
o $30.00 REINSPECTIQN FEE REQUIRED. Prior to reinspection, fee must be paid at
6300 Southcenter Blvd., Suite 100. Call to schedule reinspection.
.......... . tOt.kn.\ti..,t ram.* wir..,,.,..e.n..ka,._ _.
To: tor. Duane Griffin
To:
From:
From: Fenton Kraft
Mr. Duane Griffin
Building Official
City of Tukwila - Permit Center
Department of Community Development
Fenton Kraft
HVAC Manager
Museum of Flight Foundation
Project: Museum of Flight Boiler Retrofit
Mechanical Permit Number M94 -0001
11 -4 -94 2:23pm
November 5, 1994
Re: Request for Extension of Building and Mechanical Permits
Recently I received a letter from Shelly Bates notifying me that our permits were
about to expire due to the amount of time that had passed since our last inspection. I
called Shelly and she recommended that I contact you and request an extension of our
permits for the boiler project. Although we are nearing completion with this project there
are several items still remaining to be resolved or completed prior to being ready for the
mechanical and building final inspections.
During the last two weeks we have had the factory representative calibrate and test
the boiler operation, obtained certification from the State licensed boiler inspector, and
activated and tested the automation system. Next week System Control is scheduled to
complete the installation and testing of the boiler room heat detector as part of our existing
fire protection system. Once this is complete we will be ready for the fire final Inspection.
The following week we will call for the electrical final inspection.
Among the items still outstanding are the completion of roof flashing and gutters,
sealing of conduit penetrations within the museum, fabrication and installation of
escutcheon plates, and the installation of a differential pressure transmitter.
With the above items in mind as well as the time required by other museum
projects, I anticipate that it will take a little more than a month to complete the items
remaining. Thus if possible, it would be a great help if you could grant an extension of the
building and mechanical permits until the end of the year. I do appreciate you're
consideration of this matter and look forward to hearing from you.
Sincerely,
Museum of Flight
9404 East Marginal Way South
Seattle, WA 98108 -4097
Tel: (206) 764 -5700
Fax: (206) 764 -5707
..ti
kutit
Fenton Kraft
RECE 5t)
g4/S,o /7 7/0/ °j
Z err /�ecr �%r .�/ ii 5 d �e eet' Pr/ //Y s 7� 17j .
Ateted
1174 6°
„i¢ /O,/
to 04199+
Gp1vt`q► PMN Y' 1
s,�r eEtvv�ork ; s� �Ir�ea�r►I�
p. 1 of 1
Oct 03, 1994
City of Tukwila
John W Rants, Mayor
Department of Community Development Rick Beeler, Director
FENTON KRAFT
9404 EAST MARGINAL WAY SOUTH
SEATTLE, WA
981084097
RE: MUSEUM OF FLIGHT
Dear Permit Holder:
Our records indicate that on Nov 09, 1994, one hundred and eighty days will
have passed with no inspections having been called for under Tukwila
Building Permit Number B93 -0475. Unless you call for an inspection,
or obtain a written extension frbm the Tukwila Building Official prior to
that date, your above referenced permit will become null and void on
Nov 09, 1994.
If your project has been completed please call for final. If you are
actively working on it please notify our office.
If you have any questions or need further information to obtain an
extension on your permit, please call the Tukwila Building Divison at
431 -3670.
Sincerely,
Shel lie Bates /Sylvia sby
Permit Technicians
Department of Community Development
6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • (206) 4313670 • Fax (206) 431 -3665
SEPARATE 0
PERMIT AND
APPROVAL
REQUIRED
DESIGN TEAM
OWNER
Museum of Flight Foundation
9404 E. Marginal Way South
Seattle, WA 98108
Telephone: 206 764 -5700
Fax: (206) 764 -5707
Richard Beckerman
Project Director
ARCHITECTS
Gregov Architects
1218 Third Avenue #1200
Seattle, WA 98101
Telephone: (206)622 -6990
Fax: (206)343 -5595
STRUCTURAL ENGINEERING
Carla Keel Group
1218 Third Avenue #1200
Seattle, WA 98101
Telephone: (206)628 -9583
Fax: (206) 467 -0677
DRAWING LIST
ARCHITECTURAL
A -1
A -2
A -3
COVER SHEET /SITE PLAN /GENERAL NOTES
PLANS Ic ELEVATIONS
SECTIONS b DETAILS
STRUCTURAL
5-1 GENERAL STRUCTURAL NOTES
ascravetes cw-
M-1
A X—r2
Ax —'3
MECHANICAL SOUTH BASEMENT PLAN
MECHANICAL LAY —OUT
DETAILS
MUSEUM OF FLIGHT
BOILER ROOM ADDITION
CONSTRUCTION DOCUMENTS
NEW BOIL
ADDITION
SITE PLAN
GENERAL NOTES
- - - - — (MONO flti,Y.
nw.cnw.nn*
d' va vsysIl r• ws%
a1} O•VAavan AAAAa ' .
f•Va/tf}Ml URaVP•V•VLL
• V V arak4•• •aP •
S./ V Y =V•
ggf V*O Wa�L••
a.•..s s \ 1 11
tltltll:
11111 t T:-r ii1Ti'u111i11jii1
(.IJ111 Lt': !!l ill:; p�;1:IlIlllll11111�
.11I'II�' • , IIL••::il:rT•11, i ?111111
anwt was
1111111:' Ill1::111111111It11ull1i!t
r tnrlIntnrnnrrtl TITTIV
111121) 11111'Iltj: tin. 1:L:111111
C
stam
i Y
'"� r f.
, y ak.Y ,`y
A Y f Y
) C
OVERALL sire PLAN
GENERAL NOTES
AREA OF SITE
EXISTING ZONE
SEISMIC ZONE
FIRE ZONE
USE OF EXIST. BUILDING
USE OF NEW ADDITION
OCCUPANCY
TYPE OF CONSTRUCTION
GROSS FLOOR AREA
308.182 sq.ft.
•
1.42 Heavy
Manufacturing
3
3
Museum
Boller Room
Group 8. Division 4
II — One Hour
242 sq. ft.
SCOPE OF WORK
The Protect includes a now Boiler Room Addition at the existing Simla Ana.
Remove existing metal fence wall with doors and construct the new Boiler Room
structure on a new concrete platform, from concrete masonry units (CMU)
reinforced as Indicated on dnvings. Steel roof joists are supporting the metal
roof panels. This Project also includes mechanical and electrical work.
1. All work shall comply with applicable codes and ordinances.
2. Verify all dimensions and existing conditions on the job before proceeding
with the work. Discrepancles, if any, are to be referred to the Architect for
direction prior to proceeding with related work.
3. Where existing work is damaged, cut or defaced due to performance of
new work, the Contractor shall patch and repair same to match adjoining
surfaces. Repair finishes shall be extended to the nearest visual break
lines such as corners, ceiling lines, top of ban or similar.
4. When items an noted on plans to be removed, it shall mean the complete
removal of the work Indicated and the associated patching and repairing to
match adjoining work.
5. See mechanical and electrical drawings for additional notes and symbols.
8. The Contractor Is responsible for the review of the structural, mechanical
and electrical drawings for cutting and patching work within the building,
beyond the limits of the architectural drawings.Provide sleeves for
mechanical and electrical work.
7. The Contractor shall verify all rough-in dimension requirements for
equipment furnished and installed by himself or others.
8. All contractor installed items shall be supplied with required mechanical
and electrical services to provide operation of items installed. Provide
required mechanical and electrical services for items Installed by others.
9. In general, the plan dimensions shown an n follows:
5. To the face of CMU walls
b. To the face of concrete
•
1
10. Provide closure, meeting the requirements of governing firs authorities,
batwaen all fin rated floors, shafts and building partitions and any
penetrating ducts, pipes, conduit, mechanical, electrical and other items.
11. All wood blocking shall be fire- ratardsnt
12. Wood in contact with concrete or masonry shell have • preservative
treatment.
LEGEND
A5.1
WIRINCE
NORIN
—11- 11 =11 =1I
11= 11- 11 =11=
Or
BUILD. SECTION N0.
SHEET NO.
DETAIL NO.
SHEET NO.
ELEVATION NOS.
SHEET NO.
NORTH ARROW
EARTH
CONCRETE
(CMU) MASONRYNUN TTE
METAL
INSULATION
(LOOSE OR BATT)
INSULATION
RIGID
MMMTE PEIiMfT
RED FOR:
ICAL
CTRICAL
VO P MBING
GAS PIPING
CiTY OF TUKWILA
MILLDING OMf10N
NU COPY
1 Leidefatand that the Mr Check e,-- -, ro
abject to anon and omNokt4 and cat _ Y. I of
Pin dose not elm tS *Sell ot any
sad cede sr wawa MS et see n a a
GYPSUM WALL BOARD
Pi spy�y
Pima eta, P :s �) 04-15
CITY OF TUKWIIA
APPROVED
JAN . 1993
ceiriersits
DEC 141993
rsur INS
A -1
FLOOR PLAN
1
/
EXIST /
eerA/NIAO
•
. •.
\ /YON LAC47r0N
� ' oN e" sat
SX /577NG LONG,
speutivRe
FRAMING PLAN
1
1111111111 11111
New MUM /
ewer vane. Vl AZ)
Z
Z
Z
ev6Ti/vG WA
S7Rt/GR/RC
ROOF PLAN
•
'7
A3
1 1 1
1 1I1 1
11 111(1
1 1
1 1 1 1 1 1 I_ 1 1 1
1111111!
1 1_1.1_1 1 1
•
1 1 1
. CT
,7, MOH
1 STATE 0! TON
MUSEUM
OF FLIGHT
BOILER RM.
ADDITION
ZATTI& WASMNOTON
CITY OF TUKWILA
APPROVED
JAN 1 1 1993
A'
BIIIIDI
ION
NO. IOA1E INEWSOM
DRAM !Y L • L OINOOV
CHECKED RY L la 1. MOON
DAM
Mae 134 IOU
JOS NO.
ORMANO
PLANS it
ELEVATIONS
SagiVASA WAGS
DEC 14 INS
U MN
1/4.- I'-o•
A -2
1
uw t•a .r -..a..rea Una a- r.aua. a. it 1.A{lieSs leard Yd!
eX /ST /NG RETA/N /NG CONC.
WA/.& ANO FOCI /NB
GQ4NTEA= f/ASMI/NG
-END WALL. FLASH /NG
NEOPRENE CZOWRs
/N50t4770N w/
VsWaJK RelAeace
8" sTL %/0/Sr /6 G4
2l0° o.c.
•
-- /'ASC ASOF /C /NCl/
, - aox P.Je eake P.4v&
e4 GAUGE e - Z /NCAwr/e
W/ KYNAk 5& ca4T
s &• rG€?Tef .
N
R.-eo, 1e/5 R117P METAL
GAbGE F-{,ASN /A/G KYNAle f /NCe
- CONT. mEAIE'D w
PLATE PkVfl 4x4
,vc1/rt Dar
OC. 6°LO S
2"X 41CQYT .sn..
"etc W/ 4iv
/G csne
I• "X / »K sae ? "O' Oc,
4(5 S7L. adVe.
• • . •
• �5..
t-.-
- GOWNS/491?
/4/"A 2" KYNAe F1N4SN
emu 6 X I6xB QNie.
2 - 05 sTL R Ayes
ice/`to RA/A/ OP1P
/a, G4 MEpL reArle
SA P64 n/t
- EPDXY
/N RACE
2/0•
UT &o
24.1/N GONG. S64
W/ GxG -W2.0 oaf
ON
.9f Ier�a .
a ac conoM
RfP160 MCA
1104 611ao Pea►n
txt x4' S7LActe GA
•
•
1
1
5X6
GOMT TQEAI&)
WOOD PLA1G
AN0NO2 & ft /J
G° GONG
/O'OCG
•
.••
•
-- GNU WAU.. Ef/F
*s, floe Merle
e_ 4to noe/a.
Gear, w/ /P.Ein,, M:'
ta.'ic. 606 2MM /N
!lx% r/Me • COVIG• Sae �1b+C'1G
,EMXy Gear sat IN ftA
•
cow, se4cA T
Ga'Me. FUSN/NS
- ENO WAG&
F'tAS/l /NG
— 8" STL
8tA
••■■••■•••••••••1111
DEC •
0M0 61 X/6xg
airs
14en
M
r• /17111 REGISTERED
STATE � WASHINGTON
`EXPIRES 9/2110'.
MUSEUM
OF FLIGHT
BOILER RM.
ADDITION
SEATII.E, WASHINGTON
CITY OF TUKWILA
APPROVED
JAN 1 1993
NO. 'DAR INEVISIONS
ONANN BY 4 ONEOOV
CHECKED NY 1. ONEOOV
DATE OECOSER 13, 111113
JOS NO.
OWING
SECTIONS &
DETAILS
rat woe 1/!'a1•-0•
DETMS 3e• ,'-Or
Mr Ad-3
OINCRAI STRUCTURAL NOTES
Enna
1. ALL MATERIALS. WORKMANSHIP. DESIGN. AND CONSTRUCTION SHALL CONFORM TO THE
DRAWINGS, SPECIFICATIONS, THE UNIFORM WILDING CODE (1991 EDITION), AND SEATTLE
BUILDING CODE MODIFICATIONS TO THE UNIFORM BUILDING CODE.
2. DESIGN LOADING ORITER A
ROOF LIVE LOAD
ININD LOAD
EARTHQUAKE
25 PSF
00 MPH, EXPOSURE'S'
ZONE 3, Rwy
3. faiT8114IQB SHALL VERIFY ALL EXISTING DIMENSIONS, MEMBER SIZES. AND
CONDITIONS PRIOR TO COMMENCING ANY WORK AND SHALL DETERMINE THE LOCATION OF
ALL ADJACENT UNDERGROUND UTILITIES PRIOR TO COMMENCING EXCAVATION, AND NOTIFY
ARCHITECT OR STRUCTURAL ENGINEER OF DISCREPANCIES AND CONFLICTS.
4. ant= SHALL PROVIDE TEMPORARY BRACING FOR THE STRUCTURE AND
STRUCTURAL COMPONENTS UNTIL ALL FIND. CONNECTIONS HAVE BEEN COMPLETED IN
ACCORDANCE WITH THE PLANS.
5. mamma SHALL BE RESPONSIBLE FOR ALL SAFETY PRECAUTIONS AND THE
METHODS, TECHNIQUES. SEQUENCES OR PROCEDURES REQUIRED TO PERFORM HIS WORK.
0. rtgaliMMaceaSAMI CHANGES SHALL SE SUBMITTED IN WRITING TO THE ARCHITECT
AND STRUCTURAL ENGINEER FOR APPROVAL PRIOR TO FABRICATION OR CONSTRUCTION.
CHANGES SHOWN ON SHOP DRAWINGS ONLY WILL NOT SATISFY THIS REQUIREMENT.
7. !MUMS INDICATE GENERAL AND TYPICAL DETAILS OF CONSTRUCTION. WHERE
CONDITIONS ARE NOT SPECIFICALLY INDICATED BUT ME OF SIMILAR CHARACTER TO
DETAILS SHOWN, SIMILAR DETAILS OF CONSTRUCTION (MALL BE USED. SUBJECT TO
REVIEW AND APPROVAL BY THE ARCHITECT.
5. WHICH ARE TO BE COMPOSED OF COMPONENTS TO SE FIELD
ERECTED SMALL BE SUPERVISED BY THE SUPPLIER DURING MANUFACTURING, OEUVERY,
HANDLING, STORAGE AND ERECTION IN ACCORDANCE WITH INSTRUCTIONS PREPARED BY
THE SUPPUER.
9.$IIOP DRAWINGS FOR REINFORCING STEEL (FOR BOTH CONCRETE AND MASONRY
CONSTRUCTION) AND STEEL FRAMING SHALL SE SUBMITTED TO THE ARCHITECT AND
STRUCTURAL ENGINEER FOR REVIEW PRIOR TO FABRICATION OF THESE ITEMS.
CONTRACTOR SHALL SUBMIT WALL ELEVATION DRAWINGS OF AT LEAST 1/86•19•0' SCALE
INDICATING LOCATIONS OF CONNECTION EMBEDMENTS AND WALL OPENINGS FOR REVIEW
PRIOR TO CONSTRUCTION. CONTRACTOR EMU. COORDINATE WITH REINFORCEMENT
SHOP DRAWINGS.
10. SHOP DRAWINO REVIEW; DIMENSIONS AND QUANTITIES ARE NOT REVIEWED BY THE
ENGINEER OF RECORD, THEREFORE MUST BE VERIFIED BY THE CONTRACTOR.
CONTRACTOR SHALL REVIEW AND STAMP DRAWINGS PRIOR TO REVIEW BY ENGINEER OF
RECORD. SUBMISSIONS SMALL INCLUDE A REPRODUCIBLE AND ONE COPY; REPRODUCIBLE
WILL BE MARKED AND RETURNED.
SHOP DRAWING SUBMITTAL PROCESSED BY THE ENGINEER ARE NOT CHANGE ORDERS.
THE PURPOSE OF SHOP DRAWING SUBMITTAL BY THE CONTRACTOR IS TO DEMONSTRATE
TO THE ENGINEER THAT THE CONTRACTOR UNDERSTANDS ME DESIGN CONCEPT, THAT HE
DEMONSTRATES HIS UNDERSTANDING BY INDICATING WHICH MATERIAL ME INTENDS TO
FURNISH AND INSTALL AND BY DETAILING THE FABRICATION AND INSTALLATION METHODS
HE INTENDS TO USE. IF DEVIATIONS. DISCREPANCIES. OR CONFUCTS BETWEEN SHOP
DRAWING SUBMITTALS AND THE CONTRACT DOCUMENTS ARE DISCOVERED EITHER PRIOR
TO OR AFTER SHOP DRAWING SUBMITTAL ARE PROCESSED BY THE ENGINEER, THE DESIGN
DRAWINGS ANO SPECIFICATIONS (MALL CONTROL AND SHALL BE FOLLOWED.
11. )NEPErat; CONCRETE CONSTRUCTION, MASONRY CONSTRUCTION. STRUCTURAL
STEEL FABRICATION AND ERECTION (INCLUDING FIELD WELDING. METAL DECK
INSTALLATION (INCLUDING HELD WELDING), EXPANSION BOLTS AND THREADED EXPANSION
INSERTS, EPDXY GROUTED INSTALLATIONS SHALL DE SUPERVISED BY A OUAUFIED TESTING
AGENCY DESIGNATED BY THE ARCHITECT. THE ARCHITECT SHALL BE FURNISHED WITH
COPIES OF ALL INSPECTION REPORTS AND TEST RESULTS.
C
12. CaGnETE SMALL BE MIXED, PROPORTIONED. CONVEYED AND PLACED IN ACCORDANCE
WITH UBC SECTION 2804 AND ACI 301. CONCRETE SHALL ATTAIN A 28-DAY STRENGTH OF fa
• 3000 P81 AND MIX SHALL CONTAIN NOT LESS THAN 5.113 SACKS OF CEMENT PER CUBIC
YARD AND SMALL SE PROPORTIONED TO PRODUCE A SLUMP OF r OR LESS.
THE MINIMUM AMOUNTS OF CEMENT AN0 MAXIMUM AMOUNTS OF WATER MAY BE CHANGED
IF A CONCRETE PERFORMANCE MIX IS SUBMITTED TO THE STRUCTURAL ENGINEER AND THE
BUILDING DEPARTMENT FOR APPROVAL TWO WEEKS PRIOR TO PLACING ANY CONCRETE.
THE CONCRETE PERFORMANCE MIX SHALL INCLUDE THE AMOUNTS OF CEMENT. FINE AND
COARSE AGGREGATED. WATER AND ADMIXTURES AS WELL AS THE WATER CEMENT RATION.
SLUMP. CONCRETE YIELD AND SUBSTANTIATING STRENGTH DATA IN ACCORDANCE WITH
UDC 2604(0). REVIEW OF MIX SUBMITTALS BY THE ENGINEER OF RECORD INDICATES ONLY
THAT INFORMATION PRESENTED CONFORMS GENERALLY WITH CONTRACT DOCUMENTS.
CONTRACTOR OR SUPPUER MAINTAINS FULL RESPONSIBILITY FOR SPECIFIED
PERFORMANCE.
ALL CONCRETE WITH SURFACES EXPOSED TO STANDING WATER SHALL SE AIR-ENTRAINED
WITH AN AIR - ENTRAINING AGENT CONFORMING TO UBC STANDARD 26.9. TOTAL AIR
CONTENT SHALL BE IN ACCORDANCE WITH TABLE 26,A-1 OF THE UNIFORM BUILDING CODE.
13. Stagragjact SHALL CONFORM TO ASTM A1115 (INCLUDING SUPPLEMENT 51).
GRADE 450. 41410.000 PSI.
WELDED WIRE FABRIC SHALL CONFORM TO ASTM A•155.
14. BEHMEThampo SHALL BE DETAILED (INCLUDING HOOKS AND BENDS) IN
ACCORDANCE WITH ACI 31340 AND 31593. LAP ALL CONTINUOUS REINFORCEMENT 30 DAR
DIAMETERS OR 7-0' MINIMUM. PROVIDE CORNER SAM AT ALL WALL AND FOOTING
INTERSECTIONS. LAP CORNER EMS 30 BAR DIAMETERS OR re MINIMUM. LAP ADJACENT
MATS OF WELDED WIRE FABRIC A MINIMUM OF r AT SIDES AND ENDS.
131 5 • 111
NO BARS PARTIALLY EMOEOOED IN HARDENED CONCRETE SHALL BB FIELD SENT UNLESS
SPECIFICALLY SO DETAILED OR APPROVED BY THE STRUCTURAL ENGINEER.
15. g0NCRJT= PROTECTION (COVER) FOR REINFORCING STEEL SHALL 05 AS FOLLOWS:
SLABS AND WALLS (INTERIOR PACE) 3K'
10. INK G*Q{Q SHALL BE FURNISHED BY AN APPROVED MANUFACTURER AND
SHALL 5! MIXED AND PLACED IN STRICT ACCORDANCE WITH THE MANUFACTURER'S
PUBUSHED RECOMMENDATIONS. GROUT STRENGTH SHALL SE AT LEAST EQUAL TO THE
MATERIAL ON WHICH IT IS PLACED (3000 P81 MINIMUM).
17. EPDXY-GROUTED ITEMS SPECIFIED ON THE DRAWINGS SHALL BE INSTALLED USING HIT
00100 ADHESIVE AS MANUFACTURED BY HILTI CORP. INSTALL IN STRICT ACCORDANCE WITH
ICSO REPORT NO. 4419 UNLESS NOTED OTHERWISE ON THE STRUCTURAL DRAWINGS. HOLE
SIZE SHALL BE IN ACCORDANCE WITH THE MANUFACTURER'S REQUIREMENTS.
15. V PANSION BOLTS INTO CONCRETE SHALL se KINK BOLT 11, THREADED EXPANSION
INSERTS INTO CONCRETE OR MASONRY UNITS SHALL 55 SLEEVE ANCHORS AND EPDXY
GROUTED INSERTS SWILL BB HAS ANCHORS WITH HIT C•100 ADHESIVE. ALL AS
MANUFACTURED BY HILTI CORP. OR APPROVED EQUAL INSTALLED IN STRICT ACCORDANCE
WITH THe MANUFACTURER'S RECOMMENDATIONS INCLUDING MINIMUM EMBEDMENT
REQUIREMENTS. INSERTS INTO CONCRETE MASONRY UNITS SHALL BE INTO FULLY
GROUTED CELLS, SPECIAL INSPECTION 13 REQUIRED FOR ALL EXPANSION BOLT AND INSERT
INSTALLATION.
Man
10. DONCRETI MASONRY UNIT WALLS SHALL BE CONSTRUCTED OF GRADE N. TYPE 1 UNITS,
CONFORMING TO ASTM C90, LAID IN A RUNNING BOND. MORTAR SHALL BE TYPE '8' PER
TABLE 24-A OF THE UDC. GROUT SHALL CONFORM TO MSC REQUIREMENTS AND ATTAIN A
MINIMUM COMPRESSIVE STRENGTH OF 2000 PSI AT 25 DAYS, DESIGN rm•1500 P81. NO
SPECIAL INSPECTION IS REQUIRED; HOWEVER, THE MANUFACTURES OF THE CONCRETE
MASONRY UNITS AND THE GROUT SHALL CERTIFY BY LETTER THAT THE MATERIALS
COMPLY WITH emote e 2405 (0)35 5 E OF THE IBC.
UNLESS OTHERWISE NOTED. PROVIDE THE FOLLOWING REINFORCEMENT:
V WALLS tier 0.0. VERT (2)0504r 0.0. HORIZ
IN ADDITION, PROVIDE (1) 53 VERTICAL AT EACH SIDE OF OPENINGS, AT WALL CORNERS
AND INTERSECTIONS AND AT FREE ENDS OF WALLS AND (2) 55 HORIZONTAL AT ELEVATED
FLOOR AND ROOF LEVELS, AT TOPS OF WALLS AND ABOVE AND BELOW ALL OPENINGS.
ALL HORIZONTAL REINFORCEMENT SMALL BE PLACED IN BOND BEAMS. AT WALL CORNERS
PROVIDE MATCHING CORNER BARS FOR HORIZONTAL REINFORCEMENT. LAP BARS 71'.
EXTEND REINFORCEMENT AROUND OPENINGS re BEYOND FACE OF OPENING. IF 7-0' 13
UNAVAILABLE EXTEND AS FAR AS POSSIBLE AND HOOK PROVIDE CORNER BARS TO LAP
HORIZONTAL REINFORCING AT CORNERS AND INTERSECTIONS.
FILL ALL CELLS CONTAINING REINFORCEMENT OR EMBEDDED ITEMS AND ALL CELLS BELOW
GRADE WITH GROUT. PROVIDE CLEANOUT HOLES AT BOTTOM OF ALL CELLS CONTAINING
REINFORCEMENT.
STEEL
SHALL BE EASED ON THE
A.1.S.C. •SPECIFICATION FOR THE DE8IGN, FABRICATON AND ERECTION OF STRUCTURAL
STEEL FOR BUILDINGS,' LATEST EDITION. PLUS ALL REFERENCED CODER.
21. Maga INCLUDING PLATES AND ROLLED SHAPES. SHALL CONFORM TO
ASTM AaB, F•3S K81. ANCHOR BOLTS AND CONNECT1ON 601.T6 SHALL CONFORM TO ASTM
A307.
n A t WE n:wa SQL SE IN CONFORMANCE WITH A.I.S.C. AND A.W.B. STANDARDS AND
SHALL BE PERFORMED BY WA.S.O. CERTIFIED WELDERS U81N0 E7WOf ELECTRODES. ONLY
PREQUAUFIED WELDS (AS DEFINED BY A.W.S.) SHALL BE USED.
23. METAL ROOF DECKING - PROVIDE SIZE. TYPE, GAUGE AND ATTACHMENT TO THE
SUPPORTING STRUCTURE AS SHOWN ON THE PLANS.
24. QOLD•FORMED STEELFRAMING MEMBERS SHALL BE OF THE SHAPE, SIZE AND GAUGE
SHOWN ON THE PLANS AND SHALL SE MANUFACTURED BY DALEANCOR OR APPROVED
EQUAL. ALL GALVANIZED JOISTS. PURUNS AND ACCESSORIES. 16 OA AND HEAVIER. SHALL
SE FORMED FROM STEEL THAT CONFORMS TO THE REQUIREMENTS OF ASTM A.446. Fy • 60
KSI. ALL COLD - FORMED STEEL FRAMING SMALL CONFORM TO THE A.1.S.I. 'SPECIFICATION
FOR THE DESIGN OF COLD-FORMED STEEL MEMBERS'.
THE FOLLOWING STRUCTURAL PROPERTIES FOR THE FRAMING MEMBERS SHALL BE
CONSIDERED THE MINIMUM PERMITTED.
CQMeONENT WIDTH A 1
IN INS 11114 JOIST- rJWEX16OA. 2.5 0.751 7 1.43
PURL N•4'JWEX 16 GA. 2.5 0.654 1.50
THE JOISTS SHALL HAVE A MINIMUM SEARING OF 1.S' AND THEIR WEBS SHALL SE
PERPENDICULAR TO THE BEARING SURFACE.
CONNECTIONS SHALL BE ACCOMPLISHED WITH SELF- ORIWNO SCREWS (MINIMUM
0 NO. 11.111 IN EACH AND SOTTOM OF THE RRESSPPECTIVE MENHIRS 1/S' X 1• FILLET WELDS AT THE TOP
eR1�nli�NeA
DEC 14 893
rax Se
STRUCTURAL
ENGINEERS
CARLA Ka
GROUP
1200 BEATTIE MINN
1215 THIRD AVENUE
SEATTLE, WA 98101
MUSEUM
OF FLIGHT
BOILER RM.
ADDITION
SEATTLE, WASHINGTON
CITY OF TUKWILA
APPROVED
JAN 1 1993
N0. (DA1E I REVISIONS
CRAM BY
CHECKED 5Y
DATE DECEMBER 13. 1993
JOB NO.
ORAWNO
GENERAL
STRUCTURAL NOTES
SOLE =IONS: 1/16•1' -O'
DETAILS: 3'• I'-Or
S -1