Loading...
HomeMy WebLinkAboutPermit B93-0304 - PIZZA HUT - TENANT IMPROVEMENT• cb It; •■• 4,17 ' i** 4 Pa2P, 1-kkor, E:\?, -ou1 ■ CERTIFICATE OF OCCUPANCY CITY. OF TUKWILA 6300 SOUTHCENTER BOULEVARD, SUITE 100 TUKWILA., WASHINGTON 98188 q $s at -, s� � .. •,f, of THIS CERTIFICATE ISSU D. '•URspANT, ` O ;, HE • O UIREME,N :'S OF SE•4`�.T;I.ON 307 OF THE UNIFORM BUILDING. ' D,E CE TIFYIN THAT .AT TH .,ifrIM ' O. 4: lS,S,UANGE` THIS STRUCTURE WAS IN COMPLIANCE4 'TH •THE VARIOUS *ORDjINANCES< „OF THE #.Cs'4I`TY RE'Gt , ATING BUILDING CONSTRUCTION' OR�4I ,E`-AN ALL `''APPL�IGABLE CITY FIREQOODES ! FOf T. FOLLOWING: w, r,. `�. Vie N. ' ,t , er v , d Ted �an�t :IPIZZA HUT INC ,',,,: ? °� , r'Y Permit Na,4,.;aB9'3.4,0304 Building Addr;'sstf, I1'463.8.'PACIFICi H( S .i;,4, �' ,•, . Par~ , # . 'd04000- 0902 - :- n � .3' '1 }' y�"e is X� 1 Or ne : OOJ..YM?IA PI 'ZA -,HOU ;. :./ v rare °* MX r a 1 STORE ` �” °, Occupant COO.; 0 -.2 1 << . 6 , .._,... Type of <Con�t . V t w R w4TiY{ 2L:7_f Occupar BUILDING .FOR F IV 0 MUST BE co E PREMISES City of 7iukwil�. (206) 431 -3670 Community Development / Public Works • 6300 Southcenter Boulevard, Suite 100 • Tukwila, Washington 98188 BUILDING PERMIT Permit No: 893 -0304 Type: B -BUILD Category: ACOM Address: 14638 PACIFIC HY S Location: Parcel #: 004000 -0902 Zoning: C2 Type Const: V -N Gas /Elec: Wetlands: Water: N/A Contractor License No.: ORANCDI070L5 Status: ISSUED Issued: 10/21/1993 Expires: 04/19/1994 Type of Occupancy: STORE Slopes: Y Sewer: N/A TENANT PIZZA HUT INC. 14638 PACIFIC HY S, TUKWILA,,WA 98168 OWNER OLYMPIA PIZZA HOUSE 3236 12TH. AVE:.' W., SEATTLE WA "9811 CONTACT AARDVARK ENGINEERING `Phone: 206 672 -7031 • 19730 64 AV W'SUITE 315', LYNNWOOD, WA 98036.'`: CONTRACTOR ORANCO DiVELOPMENT• INC . Phone: 714 721-1578 333 POPPY' AVENUE, CORONA DEL MAR 92625 Phone: (206)284 -4785 ' * ** * * * * *' ** * *! r***** 4*** k*****.** �t****; �k9t 4rik****�r *tlttt•k�r** *,kk "k. lock `lt�lk•k•k•k�k•k•k•k•1r�Ic�l** REMODEL EXISTING BUILDIN,G`.•f=OF FOOD, PREPARATION &.. DELIVERY. Units: O01; Buildings 001;., Fire Pr6;t'ection: DETECTORS`' UBC Edition: 1991 SETBACKS Back Right.. 'Valuation: Total Permit Fee: 911.18 ** d k***** * * *k * *k * *•• * * * *** ** *'kkkk'k' **•k' *k *,**** k* ** ** * *•k *•k* * * * *•k * *Sk * ** * * * ** • ,8(1,000: 00 Permit Center 'Authorized Signature Date' I hereby c`ert ify'that I have read and exam,i.ned:this : perr>i'i t and know:' the same to b'e, true 'and correct. All prov,ision`s of,.• law• and` ordinances governing `;th•is``work will be complied/ With, whether specified herein or not The grantingwo't this, :permit does not presume t'o give authority. to violate or cancel the'provisians of 'any other state or ;.l'o'cal laws regulating construction 6r` ,i,he performance 'of: worts .., I am' author, zed to s'i gn for and obtain this bui"l`dti'.n.g permit. Signature Print Name : _ _ S edtg !'j "Date :. 43 Q ' trdit' This permit shall become null and Vold "'if "the work, is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. CITY OF TUKVVIll Department of Co imunity Development — Permit Center 6300 Southcenter Boulevard - #100, Tukwila, WA 98188 (206) 431 -3670 Building Permit Application Tracking PLAN CHECK NUMBER 8'73-0304 PRO ECT NAME 1}I? - !`QT. �C SITE ADDRESS 1 -F(03 ` Itte,ibG 43 5 SUITE NO. INSTRUCTIONS TO STAFF • Contacts with applicants or requests for information should be summarized in writing by. staff so that the status of the project may be ascertained at any time. • Plan corrections shall be completed and approved prior to sending to the next department. • Any conditions or requirements for the permit shall be noted in the Sierra system or summarized concisely in the form of a formal letter or memo, which will be attached to the permit. • Please fill out your section of the tracking chart completely. Where information requested is not applicable, so note by using "N /A ", date and initial. DEPARTMENTAL REVIEW "X" in box indicates which departments need to review the project. EPARTME$ ........................ E PROW. QUIREMEb MEl UILDING - initial review FIRE PLANNING 04 ks t/ _CONSULTANT: Date Sent - ROUTED q NIT:' - lo /19 (?fit. INIT: FIRE PROTECTION: Date Approved - rA Detectors L INSPECTOR: Sprinklers FIRE DEPT. LETTER DATED: rJ ZONING: REFERENCE FILE NOS.: N/A IBAR/LAND USE CONDITIONS? (DYes No $,PUBLIC WORKS 0 OTHER I olaolc Iblaolq INIT MINIMUM SETBACKS: N- S- E- UTILITY PERMITS REQUIRED? U Yes (j No PUBLIC WORKS LETTER DATED: ttipppoutp w/ coNO(ito.., rnErn s 11-3 r y 3E 'Prwvkor t)evt O s AikZeinVrJ" J D BUILDING - final review INIT: tO '.BUILDING OFFICIAL IQ): • )q, REVIEW COMPLETED 21 ADRH.>vr GP r S' TtflctortA A'-L'v S 'Cr Pw q D-00 LC- TYPE OF CONSTRUCTION: -sr -1,1 CERT. OF OCCUPANCY? MYes r,No UBC EDITION (year): Viet I AMOUNT OWING: // inn .S'7 CONTACTED v Q- DATE NOTIFIED `0 — Ca1 �. BY: ` 2nd NOTIFICATION BY: (init.) 3RD NOTIFICATION BY: (init.) e.c_Ns 00 n1ro9I93 E t4 peemir Tt4(S C xis WFoD b , T,, 1.Eoi Eco I Fu floNS TO 'DATE 4ws Tr. a mTS Foe Pee! tiS 4S.: IRED Foe 61614s 614ctow oho Duos, aose-Oor Ov 060 PE etr ivi4ef ea NEcazotwe4 ?Pot 7Z> 116444Alcz Ari pet,,,' CiTY OF TUKWILA Department of Community Development - Building Division 6300 Southcenter Boulevard, Tukwila WA 98188 (206) 431 -3670 BUILDING PERMIT APPLICATION DESCRIPTION" `'! `.' >`:AMOUNT> :RCP.T..# BUILDING`PERMIT:FEE PLAN CHECKF.,EE«: BUILDING SURCHARGE: TOTAL jJ'/ SITE ADDRESS SUITE # 1 ef-Co 38 PAGIF IC. HI (DHWAy so VALUE OF CONSTRUCTION - $ 0 B UO O PROJECT NAME/TENANT PIZ.z.A HUT I"C-. ASSESSOR ACCOUNT # oo4QOo --C9a- (commercial) Demolition (building) 0 Other* TYPE OF 0 New Building Addition�Tenant Improvement WORK: 0 Rack Storage 0 Reroof 0 Remodel (residential) _ DESCRIBE WORK TO BE DONE: RBMoc'EI.. E-x.tST. But LID IN ro dpi. Fe, op FREEAR- A,TtoN DEI-LV E R y BUILDING USE (office, warehouse, etc.) REs -rAu IAA W - PELIV�RYJGARRy ooT oliLy NATURE OF BUSINESS: P Iz.z A -- o r- t u E r-.y o R, TA I-c E.. eau Tr WILL Ti-IERE BE A CHANGE IN USE? 0 No f ies If Yes, new building requirements may need to be met. Please explain: SQUARE FOOTAGE - Building: 2., 1 8 .2. Tenant Space: 2( 3 2 Area of Construction: ai- a WILL THERE BE STORAGE OR USE OF FLAMMABLE, COMBUSTIBLE OR HAZARDOUS MATERIALS IN THE BUILDING? 0-go (--) Yes IF YES, EXPLAIN: PROPERTY OWNER . 5 7 . 7 / .0 ,'f ./4 d=4 5 PHONE 2 j41. -•4.73)6 ADDRESS 3p3 Cy 12TH AV 2' ,W 5 AT]CL, WA- PHONE ZIP CONTRACTOR ADDRESS ZIP WA, ST. CONTRACTOR'S LICENSE # EXP. DATE ARCHITECT k�l rt'E7 -I1 H. 'IP613 ' HT PHONE�/Roo� 3 - 2 73 I ADDRESS c l t // g c7 - LA S Pen. I&0X428 Pled#1/ TA, f 4A-254s ZIP 4,7 0/ l.`HEREBY::CERTIF.Y::.THAT tHAVE READ.!AND EXAMINEiJ THIS APPLICATION AND KNOW BE: TRUE; ANCORRECT AND;..f AM: AUTHORIZED. TO ' APPLY :F.OR.THIS.PEFI BUILDING OWNER SIGNATURE OR AUTHORIZED PRINT NAME c. WOl-- AVER. �R. AGENT ADDRESS L9750 6,4-t2-4 AVE W S'V (TE CONTACT PERSON J E.A Wot -AVER, APPLICATION SUBMITTAL In order to ensure that your application is accepted for plan review, please make sure to fill out the application completely and follow the plan submittal checklist on the reverse side of this form. Handouts are available at the Building counter which provide more detailed Information on application and plan submittal requirements. Application and plans must be complete in order to be accepted for plan review. VALUATION OF CONSTRUCTION Valuation for new construction and additions are calculated by the Department of Community Development prior to application submittal. Contact the Permit Coordinator at 431 -3670 prior to submitting application. In all cases, a valuation amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Building Division to comply with current fee schedules. BUILDING OWNER / AUTHORIZED AGENT If the applicant is other than the owner, registered architect/engineer, or contractor licensed by the State of Washington, a notarized letter from the property owner authorizing the agent to submit this permit application and obtain the permit will be required as part of this submittal. EXPIRATION OF PLAN REVIEW Applications for which no permit is issued within 180 days following the date of application shall expire by limitations. The building official may extend the time for action by the applicant for a period not exceeding 180 days upon written request by the applicant as defined in Section 304(d) of the Uniform Buildincg Code (current edition). No application shall be extended more than once. If you have any questions about our process or plan submittal requirements, please contact the Department of Community Development Building Division at 431 -3670. DATE APPLICATION ACCEPTED CITY OF TUKWILA AUG 9 1993 PERMIT CENTER DATE APPLICATION EXPIRES COMMERCIAL- • • SUBMITTAL CHECKLIST . : . : .••• ::‘" •••• • •••••••••:"•••••••••••:,,••••:::::.•::::"••••••••::::::::;•••'•••••••••:•••,••,•••:•••:•,::::.•:•".•••••:•••:•:,•••• ' •:: ' ' ' ' N4w. COMMERCIAL aUILDINGS,ADDITI0NS ] Compotod bufldng permit application (one for each structure) riAssessor Account Number Structural calculations stamped by a Washington State licensed engineer • ' • :•"••••••,:":•-••••:--" • " • Soils report stamped by a Washington State licensed ''''''''''''''''''' • Topographical survey Energy calculations stamped by a Washington State licensed engineer or architect • •:Legal descnption ''•1•••''''P•••••' Working •••••••• drawings stamped ••• licensed .i....••••• • -•:•.".:::::.:••••:::••,•••••• ••••,••••••••••,..■.••:.Bite.:Plen::••••,••••••••:.".•::::..:•".:•'••'•••••••••••••:•• ••'•'"• •••"•••• ..... •• Architectural drawing Structural drawings • . ';,••••••.1y.: ;•••.•••".:1•••••"•••••••••••:::::::".•!: Elevations ••••••' •-• • • • •••••''' • Civil drawings Landscape plan Completed utility permit application (one for entire project SiY (6) sets of civil drawings -•'••:•••••,••••••••'•:••:::••••i•;.':••••••••••'•••:•.••••:•.::•,••,••••:::•••••••:•:',•••::••••••••••••••.•:••:•••':.••••••:.••:.:•:":::',:.::i'::::•••:. NOTE:'::Spe•litilitkperMit;applicationanddhacklist.tdpotia. utili RACK STORAGE Completed building permit application Assessor Account Number. . ".• • . . Y.* .:• LiBuilding floor plan showing • • .• Entire. space where racks will be located .•:•,"::••••..•••••• •••••••• :.• • • .."„• ".1...•••..• • .• Dimensions of all i&os •••••••'.;..•,:::,•••••••::•.,••••,•• ••• • • Tenant space floor plan showing rack storage layout,•-•eisieS:.end,c:".:•..:...... NOTE: Include dimensions of racks (height, width and length), aisles and exit ways on plan. Structural calculations stamped by a Washington State licensed engineer (rack storage 8.rand over). . • . ...• . •••• ' • s• RESIDENTIAL NEW SINGLE•FAMILY:,DWELLEIN G5IAP131110 NS-!..‘,:.,...:..:::::....:.: . .......:.,:....1:::. ...:.:., . . . „ .. . , L - i Co 6 M,eted building permit application (one for each structure) • ' ••••••• "• • • : •• • : ••• : •-• .:..• •, • • •.• :::::::•:::: • .1.• • ,....":,,....,•••.:::.:::::::•:•.••:••••••; ,••••••:.. •,•": •••„•••••"••••„••:••::::„•:::::••:••••:1'.•••"••••:"":1••••"1":•••1••••••• Legal desOription.„:,•,•••::..•.• i•.;::•••••.•....••,••••• ,, .: i. •,..-,•••,••••:•;••••::::::::::.••;.•••....„..•.:, •,„ .::::,:„ :.•,,,, • •••„., ....,... • • • .,... . .. .. . . Asses. . ••• • • '. " • : : •:.: • ••• • •:"..:. :„ .. • ••.',:••..••:•:•••••:::•••••..:::•1:::::•:•••:•••••••••:,....:••••,•::".••••::::"•:•••••:i:•:. ••••••:::••••,::::: sor Account Number • , : : :•,,:•;.•.,,,,,:-. ,,. ,„„,........... .. . • , .. ' ' ' '" - " " ' ' - • " ' ••• • • " ' • " • — •" ' • •• • •••• • E Two sets (2) of working .cfrOyiiincji,)0161.i::triCliide,:::::::::::::....':: • ' • • A .r.• • '' Assessor Completed Accoun: Site plan t Two (2) sets of • Location of tenant space • Existing and proposed "."., .parking • Landscape plan (if applicable, 1 o change 0 Overall building plan Tenant location • Use of adjacent (common Waif) tenant • Overall dimensions of building or square - .,. • footage Floor plan of proposed tenant space • Tenant • Exit doors space plan • ' ' ••• ' egress • patterns 0 Construction details all existing • attachment for floor and ceiling iii: Structural calculations stamped by a Washington State licensed engineer may be required if structural work is to be done (2 sets) NOTE Ifany utility work Is to be do,ie. submit separate utility permit application and plans REROOF Completed building permIt application (one for each structure) 1 I matenal being installed ••••••1:••,••••••••••• mae, [J NOTE A at/on:letter • off of the permit Aises°'''••••""1"."''' ' ' • ' ' ' • :.Narratjvd ..:':.:.:-:,..•.,.,::::::,:.,.......,:::,:::f::...::::(:::::::,:::::::::,;','''. ' ::::.:','.....;:: jj:::' iiii6::tiii.iii)'fOr:014§1);9ur',":".;.,.. iitSIDENt!A■-'REM9D...: ,.,..;•.:,........:::;.,::;:v:..!::::::„.g,..:.;,,.„... . .. .,. , ,,,,..,..;!:'!..:;:•:.:••••!::: Completed 12i,ilcifrib:0011.1)!PPP...?:.•,.....••:,.,......,:,•..:::,;,:..::;,::.....:,,..:::::::::.::.::::'.,;..,..::::•:...; ,:::.‘...,..:.;,.. "A.::,......i.::::::,...:::::..........•,::::':::::::::....:- - .: .....,..,-,..yn• . 6.....,•-,...:.:.:.:.:::::•::.:'.1;.:,:.::::::::i.::::.,.:::".'::'..". '''.',..;:.....' s seiiO'r, AcC9t.ii4....I.V.....!!....,7!,•:;;;J::::;,:,...;;;......-............ .,,,...:. ,.. '. iiiiii6i ;, which i.I 6.0.1.4 ..:TuO::(.).'6ett:O.:Wrirldna drawings ..ra.......,..,.......•::::,i.:;,..;,,.....:,...... S.iiiii.iiiii):::::-..::.•$:::;. ', ,:::::::•:'.: ..:„....::.::..::.,:i........:.1:''...:::::1:...,;F66UIiircipillitinci...:,p7: F1 ;...:,!...!....:.:: A0af..plaii:fis.:::.:i.;:',.:.::::....... ..... • . .•,..::•:',,:,....,....••••••••••:•......•......:-,•;.:, Build ng. • framing .. nliins:::„:,,,,,.:: NOTE 11 any :...,•'...Buildinii:eleatici.O.l'aq.•:Y1. ,........,........„..,...: ' •,..."...•,•,.....struoitU±a■..r•oss'$..?•••!;•••• .,-,....':,:.........;::::',.. • ... , .. , :.,, , • li . „.....::: ' ' ' .. :•.• ...":': ' '' . '.. : ' / iv. be done prc....„.... ty p .1 dtion „,•,.:...:1,...::::::,..::::::::::::::,,,,......,:::::::::.,!„..., and oirie'mult...:40 !br : ' .s.I.itilted. ' .,-....,...... ' .. ' .....:, ..:,.:. :i'''.,..L.: .. ...........'..: . .. . ,... .. ..... .. . : ..... . . ........ .. Site plan •• • ' • Foundation plan Inclide•ae aess to building, showing : • • 1 : •-• Floor plan :'," • •.• width and length ...of. Roof plan .,.....•••••••••..•:, .••• : . . ••••••.:.•••1•'•...:••••.'"•:.•:".•"•:;.••:::1•••• • ••• Building elevations (all • Building cross-section •••• • • • • • • • •••• .• • • •• • • .• ••••••• •• ••••••• • • • • •••:•••:•••:1-.1, Structural framing plans :";•:.• •••••••••••,:••••••"•:::::' :"•'••• ••••.'.••••"".:: '•:.'"::."•:•;:•••2:::.'•••1'•:••":••••••••••••••'••'••••••:••••.•••••• . • • :::• • ••• • ••••••.:..... F-1,Waanington State Energy Code data .:••••.:•••.,•.• • :••••••„.:: ••••:•• ••••":' • . .; . Completed utility permit application Six (6) sets of site plans showing utilities NOT4'[:,Biiilding site plan and utility site plan May 00:CombineCl... See utility permit application and checklist for:,spebilic subminal requirements.' Additional topographical and soils information may be requiredli.imique..' • ••• • ••••••.". CITY OF TUKWILA Address: 14638 PACIFIC HY S Permit No: 893 -0304 Tenant: PIZZA HUT INC. Status: ISSUED Type: B -BUILD Applied: 08/09/1993 Parcel #: 004000 -0902 Issued: 10/21/1993 * k****** * * * * * * * * *k* * * * **k * **********k*k k** ** ***** ** *k**'k *k•k** *•kk **•k•k•kk-k•k** Permit Conditions: 1. SIDEWALK ORDINANCE APPLIES;:' AND' SIGNATURE; ON. DEVELOPER'S AGREEMENT FOR FUTURE IMPROVEMENTS ARE " "REQUIRED. . THIS AGREE- MENT MUST BE SIGNED' >PRIOR TO FINAL INSPECTION.' CONDITIONS IN AGREEMENT TO INCLUDE: 1) FRONTAL IMPROVEMENT AGREEMENT WITH CONDITION OF/AI,SINGLE' DRIVEWAY WITH PAC HWY PROJECT TO MEET STATE REQUIREMENT ;:.OF :ACCESS" CONTROL ON STATE HIGHWAYS; -SUCH AS SR -99, 2;),PROVIDE`,SIDEWALK 'EASEMENT,FOR FUTURE SIDEWALK AS SHOWN r'•.;ON' PLAN' :.SHEET: ,' SITE'; PLAN - 1; PROVIDE ACCESS PLAN TO PROVIDE FOR ..FUTURE SINGLE-DRIVEWAY FOR CITY APPROVAL. 'IF',. YOU HAVEt2'ANY QUESTIONS PLEASE; CALL JOHN PIEROG AT 433 -0179. DEVELOPER'S AGREEMENT TO.'BE° IN CITY' FORMAT AND SIGNED 'BY PROPE6t7Y OWNER. 2. APPLfICANT. :I:S RESPONSIBLE FOR ENSURING PROJECT BUILT: AS, SSHOWW EVEN A7HO,UGH NO SURVEY= HAS _BEEN• PROVIDED. FUTURE DISCOVERY OF INACCURATE nCONSTRUCTION (It E. UPON4ROAD..IMPROVEMENTS) WILL `REQUIRE PROJECT RECONSTRUCTION :.AS NEEDED. 3. NC o o cht' a ng e s lwi •H. eMade, to 'c r tHhee . unl ess . approved b y th e Architect:.a :nd:,the Tukwia Bulding`,Division 4 . Plumbing b.e obtai ned 'through the SeattleK i.ng Dedartm.ent of PubialthP1umbi`ng will be i nspected 6 ` that agenc�inc l udi,ng ` a,],1�.'.gas ,,piping (296.;4722);. 5. Ele .t :r`,ic{•erm•it shall be obtained th,rOugh, the'. Washington State'srDiv;.is,ion of Labor and Industries x�a!nd,,,a1� :l electrical work 'w1 1`�.b,;e ��insp`ected by that a e"ncy (`248663,0) . f"� 6. All mechanical work, shall be under Separate permit through the City , pf Tukwila` :: 3 >, 7. All permits, ins e:etion,records, 'and approved;plansx , shai maintained' vai5]:ab -le at the job site pri,ori`to theart any construction. `._These documents are`'to be maintained available u4,i1,,.,final inspection approval is granted,o 8. Any new ceili'n.g`:gr,,"id and light. f.;ix`turea-installatiois required to mee;tteral bracing requirements for Seismic Zone 3. 9. Partition walls attached.wtn;';ce.,i :1 in g r.f1= 'mus'tbe laterally braced if over eight (8) „ °feett, #n > ^ie „11.g "t.h :r 10. Any exposed insulations backing material shall have a Flame Spread Rating of 25 or less, and material shall bear identi- fication showing the fire performance rating thereof. 11. All construction to be done in conformance with approved plans and requirements of the Uniform Building Code (1991 Edition). as amended by the Washington State Building Code, Uniform Mechanical Code (1991 Edition), and Washington State Energy Code (1991 Second Edition). 12. Validity of Permit. The issuance of a permit or approval of plans, specifications and computations shall not be con- strued to be a permit for, or an approval of, any violation of any of the provisions of this code or of any other ordinance of the jurisdiction. No permit presuming to give authority or violate or cancel the provisions of this code shall be valid. 1't Thnwo e.t - 1l Ma nn .ten ....vn•. .. •. .r Ml. t...4i 1J f l a 11 i1_� f final inspection has been completed by the Tukwila Building -�; Inspector. C7 ws;« ��a< biSAH `r�!x•�w:�,!•s� +c��ff•r�i+.l e.�v�i *kk * *4! *•k * * # * *k ** k****** * * * * ** *k * * *k*k*A * *•k * **h * * **•* *fir k * * **N * *k* CITY OF WA TRAN8M =I'T * * ** *** * * *** * **.**** 4*** **** *A *J****•***h*** * *** *J•k*** *** ** * ***•k* TRANSMIT Number: 93001073 Amount: 357.18 08/09/9 • 14 •59 Permit. No: 1393•-0304 Type: B -BUILD BUILDING PERh� f1/`�3 Parcel. Noc 004000 - -0902 Site Address: 14638 PACIFIC NY .5 Payment Method: CHECK Notation: PIZZA HUT OF JAN Iriit. SAO *** k** k****** *k*******J***** ***k ** ***k * ** *Ar k ****** * *** *** * **** ** Account Code Description Paid 000/345.830 PLAN CHECK - NONRES 357.18 Total (This Payment): 357.18 Total Fees: Total All Payments: Balance: 911.18 357.18 554.00 GENERA 357.18. TOTAL., :.:.:..: 357.18 CHECK: " 357.18 CHANGE 0.00 3360A000 13:17 ********** k******.****'************ ****** *k* ** ******* ** ***** **A*** CITY OF TUKWIL:A, WA TRANSMIT *********,******** k***** h***** h** * * * * * * * ** * * * * * ** * * * *** * * * * * *k *k TRANSMIT Number: ; 93001533; Amount: 55.4.00 10/21/93. 16 :11 Permit No: 13.93. 0304''" Type:: 13-BUILD BUILDING PERMIT Parcel No: 004000- -0.90 Site Address: 1438 PACIFIC HY S Payment Method: CHECK Notation: ORANCO DEVELOP Ini1 1il259,11 ******** k**** * ** *k** ** *kk ** ** *k *kk * * ***** ** r *kkk * * * ** ****** * * ** Account Code 000/322.1'00 BUILDING NONRES 000/386.904 STATE RUIL01NG.SURCHARGE Total. (This Payment): Descr'iptiari Paid 549.50 4.50 554.00 Total Fees: All Payments: Dal once: 911.18 911.18. .00 GENERA 549.50 GENERA 4.50 GENERA 10.00 GENERA : 15.00 TOTAL 579.00. CHECK 579.00 CHANGE 0.00 5585A000 14:21 City of Tukwila Fire Department John W. Rants, Mayor TUKWILA FIRE DEPARTMENT FINAL APPROVAL FORM r PO 7it Project Name P; t-1 ut Thomas P. Keefe, Fire Chief Permit No. G?3-03C1 Address /9(3 Poe-;Ccc... S. Retain current inspection schedule X Needs shift inspection Suite # Approved without correction notice X Approved with correction notice issued Sprinklers: A) Fire Alarm: Heed-kr. Adis Hood & Duct: Al Halon: Al Monitor: jj,/.2±1...C7‘,4 eth h Pre-Fire: Permits: 4e 9 7; 464,1b, Authorized Signitture FINALAPP.FRM -j/ A///e/ 5'3 Date. • T.F.D. Form F.P. 85 Healquarters Station: 444 Andover Park East Tukwila, Washington 98188 Phone: (206) 5754404 Fax. (206) 5754439 INSPECTION RECORD C Retain a copy with permit 'IN 3-- U3. A CITY OF TUKWILA BUILDING DIVISION St+►�4 6300 Southcenter Blvd., #100, Tukwila, WA 98188 1 • 431 -3670 •Iv •., 7 F/0 Ld Add rol 4$ J4 C ((t G 41 -Date Called: fz _ _ q Special Instructions: Date Wanted, Z — M Requester. s_ G V e,. RuleNo.: 0-44 D37Y) Approved per applicable codes. COMMENTS: ••• :i for to approval. IInspector: Dace : /_ /O— . 3 O $30.00 REINSPECTION FEE REQUIRED. Prior to reinspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. e: INSPECTION RECORD Retain a copy with permit CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206) 431 -3670 Project: (3i zZ� vv Type of Inspection: �w t nal Address: I LI lo3b PUE..1ki L. V .‘-} ate Called: Special Instructions: Date Wanted: am: p.m. Requester: Phone No.: Approved per applicable codes. COMMENTS: ❑ Corrections required prior to approval. ❑ $30.00 REIN 'PECTION FEE REQUIRED. Prior to reinspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. INSPECTION RECORD C Retain a copy with permit CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 �i a \0-k ° ns�° vto.min F'incd Address: I Li 01:3 pu.1ki( ioi ,5 Date Called: Special Instructions: v Date Wanted: 12/ l / `..? am. J Requester: Tare- Phone No.: Approved per applicable codes. ❑ Corrections required prior to approval. COMMENTS: icktp ct70,61_,4,..,,, V'.��..�` Inspector: ❑ $30.00 REINSPECTION FEE REQUIRED. Prior to reinspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. INSI ESCTION RECORD Retain a copy with permit CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206) 431 -3670 /7�ZAC1L;t' YPe . Ik) A f Ad�rr g G Date Card h `�' Sc 4-c2:1-.) t.r C.1A r 1=1 • -r-IA ,t,a.--5 ID r IL, 0- /,t= ltnOs►nJ id !� Date Want r - (9_ 31-5 -Aequestec am. 3. k/ 12�-51`►t..* -a 1., 1~.Pc-‘1 S A -,: R+.U, ■ 12a12 —m 19`rv'E -- O Approved per applicable codes. (Corrections required prior to approval. COMMENTS: 1 0 6 r.1 r-'t ii.: .-...= g tam._ . (L c1PA -i r+-- c-' i.1 r4C. 1 ►.► S u t A-TIn O . 3 Sc 4-c2:1-.) t.r C.1A r 1=1 • -r-IA ,t,a.--5 ID r IL, 0- /,t= '-" 11 t-va'.' C)l ■--1J ti 1 N SP:-cx�ao i . . 4) 12�-51`►t..* -a 1., 1~.Pc-‘1 S A -,: R+.U, ■ 12a12 —m 19`rv'E 1 1.1.-Su. LA-'`e LA-\/ I- S. (, r..r►M t o A A-i►u r-1O 1-c 1 cETS . ' [inspector, [T3 O $30.00 REINSPECTION FEE REQUIRED. Prior to reinspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. [1'4' 0 INSPECTION RECORD 0 Retain a copy with permit CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206) 431 -3670 re 12;_ -6k( G Type ou�.p�L) Alma O /j' eA ce i e Call : q T�" Sp Instdilons: Date Want Requesters : .1--.G-9.10 T6 s �'c"�,1 trl� a;,,,ll,. riet; TILE-, Phone No,: 4,... / — 5 5 a ❑ Approved per applicable codes. 11'5 Corrections required prior to approval. COMMENTS: C€?6/ A/( 6 A-i a (ARV-A— 15 Go, li'v-rX..- ; r Pe- - L-1(7-44i-3 A t,-JO . j) t r 5 -' , 4 - : 1 7 y . \Jk-- Oh-- .1--.G-9.10 T6 s �'c"�,1 trl� AN. 9 a;,,,ll,. riet; TILE-, spect er: i)rx ❑ $30.00 REINSPECTION FEE REQUIRED. Prior to reinspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. INSPECTION RECORD C Retain a copy with perm! CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 981 PERMIT NO. (206) 431-3670 • r . : & 0 A. 4141 allierffe 4L/ Tee e ' 7- ' : Tja Lk,. Ary Int / ireoilWeATZEili ph e ei, • : . ..... -- c7 • :..: , struct : i Date ant: .. Z----- 93 . . Requeste : Phone No.: ...) .0,--- 3 3.,__Approved per applicable codes. I COMIANTS:.L....— 0 Corrections required prior to approval. 71-e, pve4e--N 0 $30.00 REINSPECTION EE REQUIRED. Prior to reinspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. 0: INSPECTION RECORD 993_Cj -3 Retain a copy with permit " t CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 PERMIT NO. (206) 431 -3670 Project: ; j1 ( �: / type of Inspection: �� Date Called: Address: (c4 tivii Special Instructions: t Date Wanted: Requester: 4:4? Phone No.: Z[- 3 Y a 1 XApproved per applicable codes. COMMENTS: ' O Corrections required prior to approval. ❑ K c.00 REINSPECTIO FEE REQUIRED. Prior to reinspoction, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Recelao.: �kde: INSPECTION RECORD Retain a copy with permit CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 63 -o3ot PERMIT No. (206) 431 -3670 'to ect: Pizz..l r C111� ype o nspect on: {� , I V (x \ 1 ii sisui.,4 Address: I, I (0 pad k l� kk Date Called: Dale Wanted: I Qy @(0 Io- -Q-) -q am.m�. Sp at Instructions: Requester: Sk--ev IL- Phone No.: + , \- 3`'1 Approved per applicable codes. 0 Corrections required prior to approval. 0 $30.00 REINSPECTION FEE REQUIRED. Prior to reinspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206) 431 -3670 • ro : p. � / i 1 ype o nsped . n: ,r e Address: Date Called: Sp: • : nstnlct ons: II: e "ant: . /4-- am m Requester: , Phone No.: t .. pproved per applicable codes. 0 Corrections required prior to approval. COMMENTS: ' 0 $30.00 REINSPECTION FEE REQUIRED. Prior to reinspection, tee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. SPECTIO ' O. 0INSPE TION RECORD Retain a copy with permit CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206) 431 -3670 r a Project: A. o C. Type of Inspection. , ti 11 ll // • .. ress: l�(l /7 tp '.te C.:.: 10 - 0) ,) -C 3 opyr-- e.h Del—Per ' . Special Instructions: C► Date Wanted: rr�� � �V - ''�.,-.., ci-? am, .m. Requester: �p, Phone No.: 014( i . ✓0 0 Approved per applicable codes. Corrections required prior to approval. COMMENTS:L4Ai, /j % ,cubs 0L' J 0 f 1 /tom I' ee(J. -) S h c 4e- dt... f Ix 1/ i:4-2 pas; L tAi e/LP w 069a oc.- ,$ i ,—z et.; a 7i- Gf ft 4,4. /.e t1-ti/ - v _ `' i �^e. v, S & _ e4r ^601-7-tc uI off', ,r4- . /i/01c— ; %.ti- & te.,,ef s r_ses4 (fr.? «?- —6-01-) . ,0-e 17)-7.9 (.4..././4 opyr-- e.h Del—Per ' . , ,-.G b/7 k d a e z..,.//15 10 A p.0,1,7 0,-, // qt.- ! A co,' 4 // Inspector: 01.E Dace: /0.2.5_93 0 $30.00 REINSPECTIO FEE REQUIRED. Prior to reinspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. [RecetNo.: Date: i City of Tukwila John W Rants, Mayor Department of Community Development November 15, 1993 Mr. Dan LoPriore, President LANDSCAPE BY DESIGN, INC. 3020 West Garfield Seattle, WA 98119 RE: Pizza Hut Landscaping (B93 -0304) Dear Mr. LoPriore: Rick Rtot' • 'pctor As the primary reviewing planner for this project, I am responding to your request for confirmation of statements by Ann Siegenthaler. The following is accepted subject to approval by other affected departments : 1. substitution of plant materials with available equivalents, 2. use of "Pacific Top Soils" mulch, 3. deletion of landscape fabric, and 4. substituting spray heads in place of drip heads (check with Public Works for any required coverage diagrams). All changes shall be entered on revised plans prior to calling for inspection of affected project areas. Please call me at 431 -3684, if I can be of further help. Since ly, //ye"-- Vernon Umetsu, Assoc. Planner. For instance, if the landscape fabric is needed for erosion control, Public Works Department approval will be required. 6300 Southcenter Boulevard, Suite #100 • Tukwila, Wash! ton 98188 • (206) 4313670 • Fax (206) 431-3665 LANDSCAPE by DESIGN, Inc. 3020 W. Garfield Seattle, WA 98119 (206) 281 -1554 LANDSD *099NK Anne Siegenthaler City of Tukwila Planning Department 6300 South Center Blvd. Tukwila, WA 98188 November 1, 1993 RE: Pizza Hut Landscaping 14638 Pacific Highway South 1!)9,7-0104- Dear Anne, Per our telephone conversation, I am writing for your approval on the following landscape items at the above referenced project: . Allowing for plant substitutions (due to availability), . using plants with the same growth pattern. • Using "Pacific Top Soils" mulch. • Not installing landscape fabric as specified in plans. . Using spray heads where 'DRIP' was called for, keeping spray heads away from walks /drives. I look forward to receiving your correspondence regarding these items, and I thank you for your cooperation on this matter. Sincerely, DJL /rmg Dan Lop lore President RECEIVED K1V 41993 COMMUNITY DEVELOPMENT o /2,4 S 1-4ELL_Lz - PtAJ IA s ) 0-0 (qa (-7:7 DATE CITY OF TUKWILA 6300 SOUTHCENTER BOULEVARD TUKWILA, WA 98188 * * REVISION SUBMITTAL RECEIVED CITY OF TUKWILA OCT 191993 PERMIT CENTER PROJECT NAME LEAN ADDRESS 146S? PAt..! Pew 1"F't. elm y 5'0 CONTACT PERSON tC .ei3 L-YO S PHONE ` 1 ° 73 7 T ARCHITECT OR ENGINEER Li'AI e-i t bEl k ,1 PLAN CHECK/PERMIT NUMBER &=:;73 - 030* TYPE OF REVISION: g) t S S 1 ✓' c/P S preou.1 UERN 61 Sv 12a SHEET NUMBER(S) S) )7E -1 3. )1 E "Cloud" or highlight all areas of revisions and date revisions. SUBMI'T'TED TO: 10 -15 -1993 11:29AM FROM Aarduarb eng FROM: FAX TRANSMITTAL/COVE TO 4313665 P.01 Aardvark Engineering Services, Inc. 2900 Westlake Ave N Suite #2 Seattle, Wa 98109 OCT 7511D3 Phone Number: (206) 281 -7379 Fax Number: (206) 281 -7471 DATE: *5 145 . TOTAL PAGES:' 2 DELIVER TO: TA.CK 174C:'ff- FiRm. INDIVIDUAL SENDING: RE SO. LY0' 4 5 PROJECT NAME: /2 24". U ' . PROJECT NUMBER: q ` 07-11 7'.._ MESSAGE: M _ �47TRTC f-� to 15 RL V 15 A LAIL1 SCsirpe S'K LETc r-! , R.E FL CT' IN C7 r l-f R Q (),51-E0 1 6Y 'NoN ME TS CON VRS.dfk .L. s'r e e Bond_. fills 5 & 14A-5 ' 13E6-4 S N TT RCN i 7 E TS ezA J/1 14;)Pii- M 1 7-tfa1 R tsd. DRAwig S , F'LYO/IS HARD COPY TO FOLLOW: Yes , No Payc. cAss, tor -- oesewe DtA' 4k'lt V'ERe4 13 Vssra (n :; 4 it X z ''4 •e4 • O ECI-ZI \<Z to "1 ,11 '41 • ' •f v• ay- 4: Ci. rat 1 • 20'd S99£T£h T'" 01 Gua 1uenp.Ped W021d Wd6Z:TI £66T-ST -OT ., To: Permits From: John A. Pierog, PW Development Engineer Date: October 4, 1993 Subject: Pizza Hut, Inc. 14638 Pacific Highway South (Activity No. 893 -0304) The building permit file for the subject project is being returned since a utility permit is necessary for the sanitary side sewer modification. In addition, the sidewalk ordinance applies and sig- nature on a developer's agreement for future participation in the cost of frontal improvements is required. The agreement will need . to be signed prior to final inspection. cf: Development File JAP /jap To: Permits From: John A. Pierog, PW Development Engineer Date: October 4, 1993 Subject: Pizza Hut, Inc. 14638 Pacific Highway South (Activity No. B93 -0304) The building permit file for the subject project is being returned since a utility permit, is necessary for the sanitary side sewer modification. In addition, the sidewalk ordinance applies and sig- nature on a developer's agreement for future participation in the cost of frontal improvements is required. The agreement will need to be signed prior to final inspection. cf: Development File JAP /jap DATE I CITY OF TUKWILA 6300 SOUTHCENTER BOULEVARD TUKWILA, WA 98188 * * REVISION SUBmnri RECEIVED CITY OF TUKWILA SEP 2 4 1993 PERMIT CENTER PROJECT NAME P/Z Z,4 HI) )4 3 4 F/ 1-7(141-7//et y s ©. 7- v /(zv /L,et , ADDRESS CONTACT PERSON ()MA/ R , -/-2ol1 PEEOL.PMATTIONE 2g / ` 7375' (54 TTL'EJ ARCHITECT OR ENGINEER PLAN CHECK/PERMIT NUMBER TYPE OF REVISION: A J7r . 1,4 /1.JSG 4 Pte PG -4.Al, A PD GP EA- s /L)-,r:/2'EP7?2 SHEET NUMBER(S) ` T s Z ' - a/ 4/ 2... "Cloud" or highlight all areas of revisions and date revisions. . 3 . C Of' 455 , J SUBMITTED TO: i"can MQ.\ 5-en City of Tukwila Department of Public Works C John W. Rants, Mayor MEMORANDUM TO: John Pierog FROM: Ron Cameron DATE: September 7, 1993 SUBJECT: Pizza Hut, 14638 Pac Hwy Ross A. Earnst, P. E., Director Proposed is to change use from retail to Pizza Hut for 7000 + /- square feet. The previous retail use and proposed delivery pizza /restaurant rates are similar. The differences for 7000 + /- square feet would not be "disting.- guishable ", especially considering that sometime ago it was a gas station. No traffic analysis4...,ers I �rcy;ov /y Me09 gar . �or� /e. Arc Goe9car4cc/ The four points of your August 27, 1993 are to be met: 41v 11A l 'fese. 1. Frontal improvement agreement with condition of a single driveway with Pac Hwy project. This is to meet the State requirement of access control on state highways such as SR -99; 2. Grease interceptor; -3. Sidewalk easement - provide a sidewalk easement or include in Developer's Agreement; The access plan needs to provide for a future single driveway for our approval. File: Pizza Hut C1ll%Agct BI015.\ qi ve. �! G '/e. w4e,7 PZ) e >1%), coi2ce4r'4S dce the 1D� /f3 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 • Phone: (206) 433-0179 • Fax (206) 4313665 City of Tukwila John W. Rants, Mayor Department of Community Development Rick Beeler, Director August 27, 1993 Jean Wolaver Green 19730 - 64th Ave. W., Suite 315 Lynnwood, WA 98036 RE: Pizza Hut tenant improvement, 14638 Pacific Highway So. Plan check number B93 -0304 Dear Ms. Green: After an initial review of the subject plans and a site visit with Dean Danardi Construction Engineer for Pizza Hut, it has been determined that additional information and corrections to the plans must be submitted to complete the plan review. Please address the following comments. 1. Provide a detailed building analysis on the title sheet. The analysis should depict the 1991 edition of the Uniform Building Code for Occupancy group, Type of construction, Sprinklers, Occupant loads, etc. 2. The submitted site plan shows the existing landscaping to remain. City records indicates that prior approved landscape improvements for this site were never completed. The Planning Department has asked for a revised site plan and /or a new landscape design that will comply to the minimum landscape requirement. For more information on these requirements contact our Planning Department. 3. Indicate on the plans how wall and ceiling insulation values will be maintain or increased by this construction when required by the Washington State Energy Code. 4. All glazing on the existing store front that is subject to human impact is required to be installed as safety glazing, U.B.C. Section 5406. Note; this correction to a prior permitted - construction was not rectified. 5. Provide details showing a method to prevent water migrating under and into wood framing of the exterior infill wall sections. Note; again this correction was not completed on the prior permitted construction. 6300 Southcenter Boulevard, Suite 11100 • Tukwila, Washington 98188 • (20$}4313670 • Fax (206) 431-3665 Page 2 To confirm you have received these comments contact this office and /or submit revisions within ten working days. Feel free to call me if there are any questions, 8:30 a.m. to 4:30 p.m. at 431 -3670. Sincerelly,I AAN Ken Nelsen Plans Examiner To: From: Date: Subject: Ron Cameron, City Engineer John A. Pierog, Public Works Development August 27, 1993 Aliagas Building Proposals 14638 Pacific Highway South Past Proposals: 1) Pre -App 90 -031, Retail Addition 2) Pre -App 92 -021, Retail Addition Current Proposal: B93 -0304, Pizza Hut Food Preparation in Existing Building { 7200 6312 Scx.Ft. ) Sq.Ft.) & Delivery The current proposal for the subject project changes the proposed use from retail sales to food preparation and delivery. The existing original building will be modified to accommodate this change with no additional space required. Impervious surface area will not be increased since additional pavement is not being proposed. The sidewalk ordinance will be triggered since the estimated value of remodel work will probably exceed $100,000 which is more than 25% of the value of the existing structure. It does not seem practical at this time to construct frontal improvements since adjacent properties have none. According to planned City improvements for Pacific Highway South in this area, it will be necessary to obtain an additional 1.5' of right -of -way or easement for sidewalks on each side of the street. In view of the above, it is my recommendation to do the following: 1. Have the developer sign an agreement for future participation in frontal improvements including undergrounding, if applicable. 2. Install an external grease interceptor with double baffles and a minimum capacity of 1,000 gallons to provide for the proposed use. 3. Require the owner to dedicate an additional 1.5' of right -of -way for future sidewalks. 4. Require the developer to submit a copy of the access plan to WSDOT for initial approval. I need the following questions answered: 1. Will a traffic analysis /trip generation - distribution study be required? 2. Should access to the property from Pacific Highway South be limited to right -in and then right -out turning movements? 3. Will a channelization /striping alteration plan be re- ' quired? S need to relay the above information to the Pizza Hut representative preferably by early next week. Mr. Aliagas is away on extended vacation (4 months ?) and will need to be coordinated with via mail. cf: Ken Nelsen, Buildings 1( Development File JAP /jap (VERNON) Electronic Mail 10 -18 -1993 9:11a Desktop File Edit Compose Ready Reply Forward Options Window Help 5fifi Date fifififififififi Time Imp From fifififififififififififi Subject fifififififififififi Box {NEW} fififi o Fri 10 -15 -93 9:12a JOHN -P re: Pizza Hut (B93 -0304) ° o Thu 10 -14 -93 10:54a CHRISTY BOXES AGAIN ° 6ee8eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeePeeeeeeeeeeeeeee8eeee£ m >From: VERNON (VERNON UMETSU) tt tt >To: JOHN -P (JOHN PIEROG) g n >Subject: Pizza Hut (B93 -0304) n m> n 0 >Need to determine if you require traffic impact mitigation. If so, a n 0 >SEPA review will be required. This seems to be indicated in your letter to u m >Ron Cameron re a trip distribution study. Please let me know ASAP so I can tt 0 >make a determination. n n> n 0 >A traffic study can be requested without requiring SEPA, but mitigation tt u >can only be gotten through the SEPA process. n MEMO, DATED 9/7/93, FROM RON CAMERON. TO J.PIEROG FURNISHED ON 10/15/93. NO n mTRAFFIC STUDY REQUIRED. Xt aeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeedeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeM Press <Esc> to quit reading. <ALT > -F -F to toggle message folding. FlHelp F2 F3Exit F4SavposF5ConfigF6ChgUsrF7ScreenF8Block F9ExportFOMenu (VERNON) Electronic Mail 10 -14 -1993 9:08a Desktop Edit Send! Record! Window Help 66e6ee6e6eeeeeeeeeee6eeeeeeeeee6e6eee6e6e6eeee6ee6eeeee6eeeeeee6eeeeeeee6el6Weef • To: JOHN -P A cc: m bcc: m Subject: Pizza Hut (B93 -0304) m Importance: normal m Attachment: <none> Receipt: No CC- Receipt: No Archive: No ma Message &a&& . A A 0 0 0 0 0 U 0 0 •m TX 0 a6e666e6e6e6e66e66eeeeeeedoeeeeee6eeee66ee6e6eeeee 66ee6eee6eeeeeeeeeeeee6ee6eeeM Create a new email message. <Alt -S> to send when finished composing. F1Help F2 F3Exit F4SavposF5ConfigF6ChgUsrF7ScreenF8Block F9ExportFOMenu mNeed to determine if you require traffic impact mitigation. If so, a mSEPA review will be required. This seems to be indicated in your letter to Ron Cameron re a trip distribution study. Please let me know ASAP so I can mmake a determination. MA traffic study can be requested without requiring SEPA, but mitigation mcan only be gotten through the SEPA process. CITY OF TUKWILA Id: ACTP125 Activity Table Processing Permit No: B93 -0304 Status: PENDING Keyword: UACT Tenant: PIZZA Address: 14638 User: 1677 HUT INC. PACIFIC HY S 09/24/93 BUILDING PERMIT Type: B -BUILD Vers: 9101 Screen: 01 Base Information Parcel No: 004000 -0902 Owner: OLYMPIA PIZZA HOUSE Validated By: SAO Plan Ck Approved: / / Status: PENDING Applied: 8/ 9/1993 Issued: / / Active /Inactive: A Completed: / / To Expire: / / C of 0 Issued: / / Bus Lic #: Final Notice: / / Nature of Work: REMODEL EXISTING BUILDING FOR FOOD PREPARATION & Location: Category: ACOM (N= NEW /A= ADD /ALT + SFR,DUP,TRI,APT,MH,COM,IND) Zoning: C2 Gas /Elec: Census Code: 437 # of Units: # of Bldgs: 1 Pub Own:N Streams: Slope: Y Wetlands: Water:N /A Sewer:N /A Setbacks - North: .0 South: .0 East: .0 West: .0 Valuation: 80,000.00 Fire Protect: Type Const: V -N Type Occ:0023 STORE UBC Edition: 1991 Occupant Load:12 Occupancy Grp:B -2 F7= Update, F2= Previous Line, F1= Screen Index, ESC = Cancel Update CITY OF TUKWILA Id: ROUT130 Keyword: UACT User: 1677 09/24/93 Activity document routing maintenance. BUILDING PERMIT Permit No: B93 -0304 Tenant: PIZZA HUT INC. Status: PENDING Address: 14638 PACIFIC HY S Route: 1 Current Route Line: 4 of 9 Packet Units Description Station Status Received Assigned Complete aaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaa Packet Units Action Station Initials Status Received Assigned Completed BUILD 01 01 C BLDG KEN Approved 08/13/93 08/20/93 09/24/93 Priority (0 /low..9 /high): 0 Regular hours (HH.MM): .00 Overtime Hours(HH.MM): Comments 1[CALLED ARCH. TO LET THEM KNOW OF EXISTING OPEN PERMIT ISSUE.] 2( 8/20/93 KEN 3[8/24 SPOKE TO HEIDI TO ARRANGE FIELD MEETING. 4[9/24/93 -- REVISIONS RECEIVED -- O.K. KEN 5[ 6, [ OCC . LOAD .. , .. 12., TOTAL 7[EXISTS .. . ... O.K. 8[ 9[FIRE PLEASE REVIEW AND COMMENT.. 10( aaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaa F1 =Help, ESC =Exit current screen. BUILDP140,ANALYSIP 4:CLIm`i CON'&TRIZi1 r . 4 . (MAX FL A ekt,00 6? WANT LOAD; • KITCHEN: IS ..(12;‘,)=v1;',0) . r61 t Ci, 't OR4fin.E t S 'EC':IFICA'!-I0N6 coNMUdTION Th$I POIDONGs ALL i4 Y41 GLAZHAbt°s WALL f3E TEMPERED GLASS CEILiNGs MINITAN R -VALUE AE OVE CEILING, IR. -30 (REt C.8 SECTION 01210) . 1 6^bALL6 EXiSTING WALLS T40 REMAIN EXCEPT AT 6TOREF'Ft7NT (WILL ' (AEI A -Al 4 RE C -6, SECTION 01210 FOR t - VALUES4 NEN NALL TO I`1A1TCf EXISTING CONSIRUCTION. Rat I -A. FM CONSTRICTION DETAiL, SWONING HATER MIGRATION PREVENTION METW00. AFC1-4 i teC`rusei4L. 5111 EAST DOUGLAS POST OFFICE BOX 426 IvdICNI$A, KANSAS 61201 EtJi4NT PLAN ARCHITECTURA. FLOOR PLAN 4 ENLARCsED CONTER PLAN IRMECTED CEiLNs PLAN 4 GETA ;L6 INTERIOR 4 EXTERIOR ELEVATIONS DETAILS J / W :C1N L wi N NNETH EIDEBRECHT STATE ,OF WASHINGTON T SZU c TU1' Ai.•. ` ►m o t t+ :::I%O%S n Check yc k a7p r ovs l % ; ot to errors and V4:1801004 plans does not i naviolg4ion 04 SW adopted copy or ordinance. Recent C trSCtOt' s Gout of app royed plans acknovvIed0. Date Permit No. . 1`1EC1.4ANlCAL,•. MECk444iCAL 4 RIMING FLOOR PLAN DETAILS AND HCH HEt3ULE6 OVEN 1400P 4 ENCLOSURE DETAILS MECHANICAL SFEC/FICATIONS ELECT i iCAL_ THIS UNIT MALL BE PROVIDED WITH A UNIT ALARM SYSTEM UNDER SEPARATE CONTRACT. CE: SHALL COORDNATE SMITH C'IVISION SECURITY F IANACaER 4 5S ELI TI 2N 5'1"1-1E5OLS The deal a- etatie diecioeed herein are the excIusive property 'of Pizza t, Inc, and-shall not be ...led or repro- duced le or in part without its prior rrttterl . come7t. @IIAAIT,I ". 5111 E. 04 .�+, . OX 8 1/4104iTA, KANSAS 61201 0 09,0y ( A ADV. A/C ACOtI t. ADJ. ADJtkaT. APP. ALT. ALUM. ANC. AJ4c_ 0. AF'F'ROX ARCH. ASPH. T. ASSTS. AT Ai f oLfr ATJOVE All@ CCMITIGNING ACOUSTICAL TILE ADJACENT ADJUSTABLE AZSONE FINISH FLOOR AIR I ANDL(ty a UNIT i TER4ATE AL.t'iiNUM ANCHOR ANCHOR 00L7 APPROXIMATE ARCHITECTURAL_ AP.i"14ALT TILE ASSEt'4°SLIEs C. C. CAPS. CEMENT Gl9. C.1, CJ. CST. CL. CLG. CLR Ct1.P. CMU, C:NTR. C.O. COL. COMP. Cl.,)NC. GOND CONST. Cc t. CJFC C6K %f3 ►'7C C,•.T. CYR. Q4114 . FLG. U r]L3! DEMO, pr. pIAM. , 0 PAM. DiSP. tr?i DO.,' DR- DA. Deer. CENTER LINE CHANNEL cc*, ES (9ixCX, ETC) CABINET CHALK BOARD cEINENT C.UDIC FEET CAST IRON t Ca(TFR'JL JOINT CIRCUIT (ELECTRIC) CTEJTCR LiNE CE lL this CLEAR CCR'LIGA1V, riETAL P .PE CONOWTE11.460NRY UNIT COUNTER CLEA*: CUT COLIC t COMM98 ITION CONCRETE corqpirioN corierRuct iON CONTINUOUS COLD-ROLLED CASE.hk' W C.MAI'11C TILE CENTER comTER 9 A°544TIG E. E. ANC. E.C.. EJ. ELEC, R1,8V. ENCI... ENTR ESL EOM. E.R. ETC. PCFUISLE . J'1OLITIC74V DE_PARTTI NT pRINXIt, FOUNTAIN DIAMETER DIMENSICr4 DISPENAER 0014)4 DITTO DOOR narcopouT DETAIL DRAWINO DRAWER I N PAST EACH EXPANSION ASCHOR ELECTRIC#. COTiRAG•TOiR EXPANSION JAM' ELECTR CAL iE.LEVATlOf4 ENCLOSURE ENTRANCE ECZIAL. EQUIPMENT t EXHAUST RE.L leTEFItt ET CETERA EX. , F:.Xi3T. EXtbTINC EX P. EXPANSION{ EXT. EXTtiRIOR IR PA. F.C.U. FDN_ PE. F.E.C. F.H. FIN. FN. FL. FL.. PLG. PP. F.5. ' FTC,. PiT. 4 GAL.v. G,l9. &J. fi:.. CO H HC. HD. F4D. WAD. HDWE. i4G . HT. HM. 1-40R17_ 14 P. iNT. INEK L. JST. Jr. K Krt. P. L. LAv. 133 LOC. LL44 LLV LP. LV. FfeSH AIR FAN COIL tt41( FLOOR ORAN FOUNDATION PIPE EXTiNGUiSHER FIRE EXTiNG.116 R C#JR•ET FLATHEAD Pint OH FINiSH FLOOR FLOOR FL.ALN 4rw/ FIREPROOF NG PULL SIZE F'C7OT/FEET FCCOtN© FUTURE wMA6. MAIL. MAX r+23. MSC. MEW Lit Mid. MLV. MISC. ML. t LOCy. P1A. M.d. M.T. MTD. MASONRY MATERIAL MACHINE BOLT R'ECIIANICAI. CONTRACTOR MECI IANICAL friAlt.FAC,TORBR M4} HOLE MINIMS"' Mi6CELLAMEOU5 PETAL LATH MC XILDRNib MASGF4RY OPF.NiNG METAL STUD METAL THRESHOLD MOUNTED rTA. MOTOR N N. NA N.C. N.IC. N.O. ?NO. NOM. NON-CGhU V. N.T.C. HOLLOT4 CORE HEAD 14,4 Yi00D ►4ARDINA.1E ;4$Kd4T HOLLOW METAL HORIZONTAL i-10A POINT INSIDE D:A11ET'ER INTERIOR INSULATION 0. TO 0. OA OIl5. OC. D. C. OraNCs. Oir'P. P4M PART P.C. P.L. F°LAS. PLBG. PLP. PL.YAD. ROC. FR. PREFAB, PRESS. PAP. Phi. PT. P•TP. raw PVC KITCHEN RICK PLATE LEEK TH LAvATO RY Ll?' AiR TAT LOCATION 02415 LEG HOISZONTAL Lova LEGt VERTICAL LOW. PONT LOWER Ll4ft4+�k$41 fit QT. F. RA R. (SAD. RD. FE. RECPy'T'. R '• Fes. REM • Rita RE OUT TO OUT OVER ALL OBSCURE ON cENTER6 OJT6IDE plat—term OfF1Ca GF'ENitZ, OPPOSITE ipEQ. IEV. RG. F2!_ r>Rri. PILO. MIST. Pi 'LASE PLATE PATCH AND MATCH PARTIAL. PLUMING CONTRACTOR PLASTIC LATINATE PLASTER PaAVS PER LIRIAR FOOT PLY•IC?OD POINT CF CO+ECTI(.TI PAIR PREFABRICATED PRESSURE FK.'191De t'ER 6GiLNVE FOOT KM* PER ty01 f!4C POINT PAINTED PN TITICN POLY YINYL t:44L.ORIDF: MATRIAL..6 0, Sid. SAN. 5. S. S.C. SCHED. SECT. SF. 514T. SIM. SP. SPEC. SR. SSA 5.5. BST. STAG. Sip. Olt. STRICT. SUST'. S.Y. Sri aII/•Rf'2Y TILE RISER RETURN AIR R P tie IRdCP DioAIN IVER RECEPTACLE REFRIGERATOR REFLECTED REGULAR REINFORCING T. T8. TON. TEL. TEMP. TEP T. 4 G. THK. rra. U U.", UL. U.V. V.C.T. VERT. VEST. VOL. V.T.R VAC. WL UL KC. PC,. WDf+I Few. WLL. KNOC"T. P1/0. FLP. WLF°. WT. INKS. STAJAF. SANITARY EEPWR SOUTH SOLIl7 CORE SCHEDULE SECTION &WARE FEET SHEET SIMILAR SPACES SPECiFICATION6 SUPPLY fevaloreft STORM ISEKER STANDING SEAM RoO►' STAINLESS STEEL STAGGERED 5TATVAITID STEEL STPXYaLSRAI,. 3ED SCLIA.RfE YARD b'rT1I ETRtCAL. NAM PAS DIFECCIC44,42. APRON KOPERTY LiNE EciBT. CONTOUR COMA 44.0). EXIST. SPOT ELEV. ((It, Sllil' III I i 16509D STUD NALL 1 ' ; 4`�7 PREFA RICATED INSULATED WALL NALLIIEENQTATION H -AI ®''---DETAIL 4 SET NUMBER DIRECTION OF VIED 'LOCATION Cf` VIEN LFtiT PATER INVERNZTERS LABORATORY u-LIT VENTILATOR MIA EaliPMENT DESIGNATION PROFOSED SPOT ELEV. TIP OF IS011 OF CURB WERT ELEVATION Opp STRICTURE GAS LIT. NATpR LHPNE L1fAI•t;7ARY SIR TEI17440NE Llhllw ELECTRIC LINE STOIC WAR RELOCATED EG ilP NT DESIGNATION DOOR TYPE REVISION KEY rEST WlpiH HITH WATER CLOSET HOOD ININDOWi HATE* HEATER WROLt l-iT IRON W4AP45C0T WITHOUT WAIEFF420012 441TE WINE WOWING POiNT t■Et644T WATER lEL.DEA I.4RE FAA= • PERMFT CENTER .t1[ : G.+: (; } ✓.n .h. cs+�:, +.�: 1"'iFM.C::_..., . .. l .=�'Ti) . . , r_.. _ .... c.. SITE L' F1)ctt (S) LAVOCAPE MGM TUN AREA -*DETAIL OR GROUP OP DETAILS SIT "``�- ---� -i IREC ION t VIED - -LCJCAT1GN G SECTION ILD SECTION FLOOR l =IMI l CEIo4 FINRI'I CEILING I WO R DESIGNATION • �.: • :+., w .... .r - IjI I- E III IIl IIl IiIFjIII ill III iIl III III !I! I(1 Ij! iIl i' =t•1 rf I I l�L l I „I ilk. Il iII �I 1 I III lj Ili i.'I 4 .. f!fll ►f ►Il1�.,1lI� f lli�ll'�III I 0 16 THS INCH 1 4 3 6 7 8 7 • 0€ 6Z 8G 1? 93 SZ +,z CZ M! iIIIIIIliII! Illill�ililll! II�IlII�IIIII !I!i�!!IIII!1!IiI!!lii 0011 • NOTE: If the af1crof1lMed document is less clear than this notice, it is due to the quality of the•Qriginai. document. ZZ le O 6L 8l LL t i!:Ell,,l1! ►a.100� llllll�illi4I(14.1.0 I, + t 1i!1I1! 111111lij !1II!!!1IIII!1!,!Ilfllli 9 I 10 11 MADER MADE etRxY 12' 91 SL t l £``L ZL l{l O� 6� 8 L , 9I S+ �- C Z IL NW 0I IIliiII�I Iil��lil� I!i 1441i1111111II0,11,!114 1111lIn fill IJ.(!(!lii,Ldilihn!Il,V iii!! iJ !1111i111!�i�lil.illlu!1!!';I1I 11,1!i!!!!II1!!f!!i!I1!!if t 1 Ii AI INC= iND 3 I TEw > SZC 4I TECTL41 .AL- SITE -I SITE f°t. AN 9 PECIPICATION3 Ac-4 I TECTUt A1W 9111 EAST DOUGLAS POST OFFICE BOX 428 WICHITA►, KANSAS 61201 EGIJI NT PLAN ARCNITECTUR4t. FLOOR PLAN 4 ENLARGED COUNTER PLAN REFLECTED CEILING PLAN 4 DETAILS INTERIOR 4 EXTEFJOR ELEVATIONS DETAILS 3172 } Su..ugEcl 10 Or1)1•!riNCE 1"fECr 4ANIC>41_ [,IJ■3 9 199,3 L-KING CO. UE+LIC HEALTH !9.`. ........... • MECi-IANICAL 4 PLUMBING FLOOR PLAN DETAILS AND 6C•EI'ULES OVEN WOOD J ENCLOSURE DETAILS MECNANI e•FECIFICATICNS !REGISTERED ARCHITECT K •NNETH HEIDEBRECHT 1 STATE OF WASHINGTON The deeign and detail& dI cloeed herein are the excivaive propert9 ©f Pizza loIut, Inc., and &ha I I not be cued or repro - duced in whale or In part without tie prior written Consent. 0191/ PIZZA IWl,1T, INC. 911! E. DOUGLAS, BOX 428 WICHITA, KANSAS 61201 • LrEdCT' 'ICALn TI415 SHALL f3E PROVIDED iTh -I A UNIT ALARM'°! i'STEM UNDER SEF'' TE CONTRACT. C.E. SWALL COORDINATE TI4 olvt5ION SECURITY + NA&ER SCWEDULES 4 DETAILS ELECTRICAL. POP ER PLAN ELECTRICAL LIGI- ITINCG ,r. At~3EIRE U' i IT IONS AL3v Arc ACOUQ T ADJ. 4DJu9 AP?' rs +u. '4 T. ALL.M ANC ANC. a APP RO:e ARCH A4'Y9 L. ESL DG DLK. 8L EsBari DIRK m. 81'1 L'.q. CEMENT C!^. C.I. Cr C C.E. CLG CLR Ci1.p C„tvTR C,O COL. COMP. C.ONG. CON T.) C.:C"EHHB t CON?. f:9F�t�C CT asfrfk FLCs. 12 DE3L DEPo DEPT pr- DiAM. , e DIM. DISE, DE,t DO r.R OS DTI. DING. DNIR A ANGLE AOVE AIR CC C)' 1;)N;Nea Aco,„ g7;CAL. T IL E ADJACENT ATaJug TA N.E ADO✓e F:Ni9•- FiC'G AiT2 HANDL NG IA:T .ALTERNATE ALLMIN!1M A.NCNOR ANCHOR SOLT .c1PPRL YIMATi ARCH' TECTURA. Ati'P1,AL.T TILE A6te-NEt_ 1E6 E QARD OftC.K. LEDC E WILDING t LOCK BELO?. EbEAM IS1_'NCH MAR' ( eaAR!NCa B�,CK E kLi! LT Lie !ROOF CENTER t. NE CHANNEL C.04.R6EB iBRV.X, ETC.) Cj}INET CHALK SO4) Rt CE MEi,T Cue;C FEET CAT ;RCN CONTROL .:o;NT CIRCUIT lzt.ECTF+'Ir! CENTER LINE CE IL CLEAR C:C R. A1tD METAL. P!P'E Cc: CRETE_ PAA&Cfi1TRT at,T COL.NTEic CLEAN CUT COLLIIN C,CX'P SITC1r costp IITION CONES'R CTION GO. OD- D) LRCLLE C IJN TEReA K CAPJEWORK C :ERAMiC TILE CE'EiR COWER FL AV IN1 E. EA E. ANC. E E EL EC EL Ev ENCL. ENTR. ECJ'1T ER ETC. Lx EXIST E XP E.X'. C FA. FD FDN FE FED. FH PN F'ht FL FL FLO. FP. F,I) FT .• FTG FUT EASY EACH EXPANSION ANCHOR ELECTWCAt (ONTRA':'OR EY.PANS-CN JOINT ELECTRICAL ELEVATION ENCLOSURE ENTRANCE EQUAL E: QUIP1E: EXHAUST REGISTER ET CETERA EXIe ZYa E XPAN6 K,N EXrE. R2IOR FRESH AIR FAN COIL LIT FLOOR GRAN FOUNDATION FIRE EXTINGiliOHER PRE E XTMIJISNER GANNET FLATHEAD FIN!QH FINISH FLC)CSZ FLOOR FLAS.4-4 s FIIR PR OF NG FULL SIZE FOOTIFE=ET FOO T INCa FUTURE GAUGE GALVANIt14D Csf•7AE1 ISAR G£tE!RAL. CONTRACTOR GA.VANiZED IRON GRADE LIKE CyRADE ]"I MAS MAIL. MAX hip3. Mc. MECJ -4 t•; 1•'1i.. MLl'G. M O. r1.1 MTD MTL. t.T f !@ NA. NC. N.I.C. N.O 0. NO NOM W.T r,. Hot. L.ON CORE HE: AD NARDi- OOD I•LARDALI ts: HEIGHT FJOLL.OW METAL. t.ICRIZCNNTA1. HIGH POLNT IN9ii >E DAAME''ER NT ERIOR ;NeULATION rxxie.LE DEMOLITION DEPARTMENT ORI Kr 3 FOLNTA+N DIAMTE R DIMENSION D'JNN DITTO >10 ;jOHNSPOUT DETAIL DiT AANGr DRAB JT KIT. K.P. MASONRY PATER AL MAXMLM MAGIJ'NE 501..1 °iECHAJCAL Ca/MACTOR MEcHANiCAL 'iANtI AC •BIKER MAN FIOLE Mi9C :..LArtEOJ5 METAL L.ATN MOULDING MASONR'•r OPEN h ET61. STUD ' At. i riRE [YNCJL L) M02 UT PD hMTAL matoft RLEcuRED RE v RSE RETURN GR :LL ESTOP LEANER ROOM RCYk,; I OPENING R.;$ S r∎CAT!{J�.i ELEVATION 0 0 r0 o. OA OBS O.C. OD. OFF. os=rtC2 OPP. V P P i M PART PG. PL PL. AS PLSCT. P.I.P. POI" PR. PEP. PT PTV P'?hi PVC NORTH NOT I.FPL'CAHLE NOM•ALLY CL 06E17= NOT IN CONTRACT NOf '"ALLY OPEN NUTIISER2 NOMINAL. N IN•C0.46 i&tit3LE 1.00' NOT TO SCA4.E OUT TO OJ' OVER ALL OPS6CURE ON CENTERS OCTS'DE D'AMETFS 01-T ICE OPEN:NG OPPOSiTE PRASE PLATE PATCH AND r•1ATC7•I PARTIAL u PP.;J SSIt+ i CQ{r - CTORUII. PLASTIC LAMINATE UL PLA ITET12 Lt.v. F'LtimeoNG POUNDS FM LREAR now Y PL.YWCAL) Y.C.T. PONT Or- CC .fECT:C.N VC.P PAIR VERr. PREFABRICATED 'TEST PPtS?P.:SUA VOL. !VA E'ER eczaw POOT V TR PONDS PER PA2LARE INCA V.$tC. POINT RANTED PARTITION POLY VINYL CIaLOR DE a 0, sa. GAN S. S. S.C. 6C:ILED o c:T 5?. SHY. S IM. ST3. OPEC. Sp S9. SSR. SST. STAG. STD STL &TRLAcT. SLISP. Sv • Q� M T T 19. T.Jl•1 TEL TEMP TERM T. R Ga Tt -lEG, THI.C, . TTP SOJAI SANITARY 'v' R SCUTN SOLID CORE SCHEDULE SECTION P•CLJAP- FEET SHEET SEMiLA,R, (SPACES SPEC!FiCATION6 SUPPLY REGISTER STORM SEVER STAIAIDI1+Yi SEAM ROOF STA!NLE39 STEEL STAGGERED 66Tla1DAR ) STEEL STRUCTURAL SUSPENDED 2l�UAi,'E YARD $111 I- IETR:CAL EARTH ccm STOW EXIST. OPG. TO BE FILLED MATCH EXIST. FINIS 44E9 PAS 144IDICAP SY41O1. PAINTED DiRECTICKAL ARRON PROPERTY LITE 6T. COMA PROPOSED CCNTOOR OWN TREAD TACK SOArai: TOP OF NALL TELc JN TEMPERED TE�W+ ZZO TC.R+YC3JE ANp GROOVE TN IOK T“REN iOLD TT PICA:_ WOOD STUD WALL PREFABRICATED INSULATED NALL N TYir` NOTAYi f -AI .*- `—DETAIL 4 SET NUMBER "-- DIRECTION CAF 11ENd L_ LOCATION OF vtEW —6480.8 TC EC Lt+LIT NEATER C9RDEM4 ITERS LSE$ RAT RT LNIT ;ENT :LA TOR NEW EQUIPMENT DESIC44ATION VINYL CCSIPOSITION TILE vFIRSFIED CLAY PIPE ,esFaEC:41. VE.STak vENT TI f1�T NRU Vf 4T'L tiA.L C FitNG RELOCATED EGUEPMENT DESIGNATiON JOIST JOINT QUARRY TILE L LAV. L.E9 LP LOC. LLH LE.v LP. LV. L W. LENGTH L 4vA7aRY POW., LINEAR FEET LOCATION LONG LEG FORIZOLTAL LONG LEG VERTICAL LON POINT LCJUVEM LErs6tT I !fibJr R TR. R, RAD. R.P RECPT . REFG. REEL MG. Rea+P RISER f aTUR'1 AIR RAT. ..":1U6 R•JC?F DRAIN RIFF'. RECEPTACLE REPERENCE REF1%c RAT0R ELECTED REGULAR !i- GReGINCa NEST N!DT■ N+n•; 'NA TER CLOSET iNDOP INi•fJON NA TER HEATER NROL CaHT iRO.•E WAINSCOT - &JTHOU1 KATERPROOF t4.IiTE PINE E V 1 CJVCs r'CJINT 1NEf:I�a}.I1 YrATE R i•ELGED KR1E FA.FiR;C: DETAIL OR GROUP OF DETAIL J !BEET Et �'- L tECTION OF vIla;H LATIGN OP SECTION A, EA:ilLIPNc SECTION c• .2aisiThnOti *-FLOOR FIND; CEILING FNNI94 CEILING l lG T WORK— ROOM /A A DESIGNATION SWEET NI�, DETAIL NUMBER PETAL ENLARCIEMENT AREA PRCX*OSED IMGATION MARS BLOC* WATER SERV1c'E DECIDUOUS TREE RECEIVE CITY OF TLJK • +cF✓iic'�i !,.-.L "%• '.y .'-r .1-,,•".'1,;-.., .•l . .. 1.5'( ♦ ?,+: ,r. , ` ..,1 Xf - I fi - . `:�f S SH J' .'sue lfl11111111` IIIIIIIIIII` IIIIIIIIII11111I1I1111111VIIIIf II ` . rill III I 1119111 ITI_: 1111 ,I , :�I1tf11111111 .11111 �{ 1jtlill I I 0 +S THS INCH 1 2 0' 3 4 5 6 7 $ NOTE: If the microfilmed document 1sless clear than this notice, it is due to the quality of the original document. 1.1 1 f1 11. 11111111111111.11, l i 11111111 1 1 1 1, 10 I 11 W E RIj1 12- S i l llL llliflilIi lllli llliI ll11101 H1i 1 1 .1 r I I(i It. d I !Mint) � I h ialsz 8C LL SZ 5z *rz I?, p? 6�iL 0 l�fi ll >a Li 91 .S. l in cl 6 )(UM !Illlli 11411049phodp4411judm p € 1111 1111 :'�'; ;A1:",tva✓��rf;;oSc"- �L>a�a-�r .t'::; ���?> Y�r•~ �`:..._.. �_ .,,..,9;�rr.�'Y,t>?�:,- sY :�:rAa ' ADD S'0" L. AN t250.A. PE.A7 AA E.. z t.TL p.:DTS: PR. ■ R. 1.) rfk , ?RE 1.-t4 14-T1 NI() :t711.11-.)Y TO Fr. W, THAT si-ra LkT1 No-r •••••••41.." •••••■■■•■■■• *Fog --PLANNi 40-1-.1;' 6.rf.E. LIC--.7 '. \ MOT ,E_' M 0 FZE. M4 A14 N r IXTURE.5 N'TYF.::: 01,ji..1i..4 ALL Ni 37— \-,\ tai- /11:,; 6 LE A PeOFE- rri" \ LI NE . .., A • -t REV TALL. LALi WIDek LAR AR5,4 cr c_ It 1201: ‘4/1-1 EEL 4.)1-0> 17) 1 pANT H1c.t-ii$4c) _cow PXt'F-114fr S , • )43. --- NO: A;-i 1...3\-kitc-c-\P t ' ,- 11(” xxs*6- Fur, 00■■••0.11% NOTE: NFsEMAflQU LELEL (Ast —n--1 3 P.RAvvit\IG 15 NEW NR>kfr1A-1101\1 A1\19 SHkLi. BE INC,LUPEp wiTH INFoRIAA-rioN N PREVI 2U3 ME. PLAN E\i'1ED 120./ct ••••••••■•■••7 4 gF.vc.se A1a-S51111., PAKItir:, REV V3 EX.117, .C-- CCARNE?, R-5 MOOWI,W, N AN REvisioNs w.i=q_E. I" -.7.2olo" MM • /1,MMI,M. R1/4/1SE:D 10/19 /c13 BY AE;:- 4 _,X9RFiatlet!Fassautywatmcsoz.v......---.. . „ • • - „ 44/ 1111111i1111111111111111111111111111111111111111111.1111figtirril M111111111 I pip 'tltr.t111!I1I1IJttfIIItIltI!I1I 11 .,- 0 ,6 11-15 INCH 1 4 5 6 7 8 - 1 0 11' GERMAKV 12' ArrAcH, -iQ s---LhE..'‘Er si-rE (NI N Orr: 10\Wal\ TIPPPVJED OCI 1{393 RECEIVED CITY OF TUKWILA OCT 1 9 i'JJ3 PERMIT CENTER .1, NOTE: I f —the iticroiilmed- document is less clear -than this ) notice, it is due to the quality of the original document. 0 C 6 8 LZ 9Z -tyr :1 CZ ZZ 07 61. 8 Lt 91. G1 L CL Et L Q, 6 8 111111111,111111,11111111111:7111141111,11.11,L , 11,,111111111.114.1, ,11,11111114.4gUI11,11J14411j4 UjlljJIJJjjilJjJ J11111111-111i111441,1,111,1611111111i1,11j111,1111111111,1111111 1 • L , 9 c t bs411 111111.1.111111II 111111111 , • . • = = „ . „ 0 ' 0" j EACE_EXITINC% II / INTERNALLY BACKGROUND TO BE Nt -IITE POLYCARB. LOZENGE TO BE 3630 -33 RED FILM. "PIZZA 4UT" COPY TO BE BLACK FILM. REFACED PYLON SIGN CONC. PIER: —N ALL EXPOSED N TO VIEW CONC. SURFACES 51-1ALL BE RU5BE D W/ C.ARi3CRUNDLiI -1 BRICK 64°4REBAR Ill ;y..�1r NOT TO SCALE ANCI -IOR BOLTS: CA5.28L.. POLE: USE 5/8" X 24" ON A 9" BOLT CIRCLE CA5 -20M POLE: USE 3/4" X 32' ON A 9" BOLT CIRCLE NOTE: SEE SITE PLAN TO DETERMINE TI-4E NO. OF FIXTURES PER POLE. (2) FIXTURES PER POLE • REQUIRES CA5 -26M MODEL POLE. BOLTS TO EXTEND 3" ABOVE CONC. BASE. Fi 'i N6 O :_"-iN7,15C '.--"Ne . SOLT CiRCLE PLASTIC C-ONPU1T 9'•*3*14 "O.C. -- - -- L_ REFER TO SITE PLAN FOR FIXTURE MOUNTING DIRECTION SITE LIGHTING - CONCRETE RASE ROUND CORNER TO - - MEET CURE'; FACE 4' THICK. CONC. WALK \ :I2 MAX. RAMP SLOPE I ?xe. 10/10 k'IAM THICKENED TO MATCH THICKENED EDGE CONC. WALK DETAIL OR EXISTING WALK CRO55 SECTION t RAMP TO 1•4AVE -- DETECTABLE IAIAR1 I NG SURFACE .lft*'i%S�" 3. .'..'�.: S':, r.GP "N.J. ,"•�,.:^ r ,ref r;4 ;_; SlDEfr 4LK A SECTION A-A `, " -0" • -- CURB (6") ,-;°. • . .717........-4—.... .. ... . ..IC I :0::0 4;:0:0:0• . : :... : •0 : • : ;• •: ,•. •. Ill r*:: ___ s. :: :; t _s A U z a. --CURB (6 ") EXPANSION MATERIAL ON ALL SIDES ABUT T- ING CONC. PAVING PLAN INTERNAL RAMP DETAIL Jl _- 6X6 +0/!O IA141 �, — - - - = — - s' I tI I- �IGKFN�t CONCRETE EDGE -------- (1 ) CONT. - NOTE: TI -4IC! ENED EDGE SHALL DE CONSTRUCTED AS SHOWN O;•v r L 4N. :1+ CWEN `EN.eioc . ; ALL HOOD TO I5E K1[N O RIEtt 'RED ' I A eRU.S T IC GRADE -1 •T -1�,1 ,_�.. (2)1'I x. 41. RAILS E!:E;VATiQN L r- - RAMP . 6,1 DIA. F?IP 6' LONG, F'L L.E�D f NIT-It CONC RE 'E. t-Gf? OF II RIPE TO BE 4,.Ot1 4BCvE SlcAr` 1C ;D.. PINT_ RED 7.I ,. 021-- 2 " 4... IRA I t TO +,. !°67' FENCE ` III CONCRETE WITS ,yP .O'• ✓E• DETECTABLE iNARNING Il SURFACE r SAND ;=ILL (MAX.) SECTION FUTURE I"..6" r.irm2::1 A' ,. -,4" 4. .SEE. SITE P'AN FOR D IMEN5; ON SEE SITE PLAN FOR DIMEN iON. PLAN EASEMENT R. .Vi3. O 10/19 /g3 As Re -7— �r,.�r• i•I'lr. •' \I-' •.,+ter. i 1_ _CC KING 1. "'— (■ EN ! E O =ENE 1 I l.,_, FA % EDGE SEE DE's Ora A'Z't°o \-- -EXIST. POWER PCLE �EGOIED 110„ x c1t� 0 111K '1{ •t r lJ ve $• GegcsR CVI Zc, "el.Ai ) 1 L !NE - - -.-+ I► fr4ALK I•: 1 , ECAST C.QNCRE1E LOIN• • f'4 R.EBAR CONT!NUCj 2 4 REBAR. TH I� RU.� � V 1 i- !EE +..FOp AND PAVEMENT.: MN, 18" LONG. 5 PREC C ITE • PAVING T CNCRETE 12;cv� •� �: 1 t G1NG . 1A S 1 pefot WHEE. S'T CP AES RC L 6'><6 IC110 >NIAII -1 ----/ I 3/4'' R - - -- i ..-tl = a A A I I r—e. -- -- t�.v ._..— _Y- 9.... - -- - - -�tjC / JV �� 1 t _ .._ -1 PAVING SAND FILLED -- !" MAX. s ======.1 — i ( THICKENED EDGE CONC. WALK SITE _PLAN_- - REPAIR EXIST- ---- ASPI -IALT PER PIZZA HUT C.E. DIRECTIONS SITE DATA I. PIZZA NUT BUILDING CONTAINS: 20!6 SO, FT, 2. PROPERTY CONTAINS 09% ACRES 3. 20 PROPOSED PARKING SPACES rA� (() LANDSCAPE AREA E _ N SCALE: I" 20, -01, V�! 200,0?' N20 °Ii 44''E EDGE OF EXIST - -- ASPI --IAL. T NOTE: PARKING SPACES IN NORT14ERNMOST ROW ARE ALIGNED PERPENDICULAR TO NORTHERMOST EDGE OF EXIST. ASPI -IALT. ig2BS N20 °05'0•"E �2 \•\ CONCRETE CURBING _ EXIST. CONCRETE APRON SITE LIGHTS (I) °ECA 152314 - 400M! 4 - QV - 5RP (PF5 °'5159'1) (2 LOCATIONS). SSS 25 -4 -!i (D -I) PFS *01599. (2) "ECA !'�31 -I - 42'®2 114 - QV - BRP (PFS *01591)(2 LOCATIONS). r55S 25 -4 -;I (ID-OFFS X1599. -1- /— 3/4" RAD. tea• r I. * f -y f�,. - -- - -- (2) "4 REBAR CONT. / 7�CONCRETE STAND -UP CURB SITED LEGEND PROPOSED CONCRETE PAVING PAINTED HAND ICAP S�'MBOL. - EXIST. METAL GUARDRAIL_ 011'('Y YP.) STR \F Nci (i A); REFACE PYLON SIGN. VERIFY ELECTRIC "", SERVICE. 1 N a- t N_ EXIST. l CONCRETE I/IALK PIZZA HUT 'EXIS ■ a BIDGJ --- PROP. i4AIAND ICAF' PAINTED DIRECTIONAL ARRON PROPERTY LINE PROPOSED SITE LICjI -!T FIXTURES 3 RAMP e E � DUMPST'ER\ `� `Q ` t.1 4i(pty, '`rc • 1, f - PROP. S E't'I (TYP.) UNDERGROUND ELECTRIC SERVICE (TYPO .I 11 ►rI'� (kr, NEVI --- - - - - -- CONCRETE \ WALK 7.-E) —PROP. 1000 GAL. GREASE TRAP. G.E. TO VERIFY CONNECTION TO SANITARY SEWER LINEPIZZA INE \ EXIST. CONCRETE APRON 4. PROP. PLANTER - EXIST. POWER POLE EXIST. i;)R1` /E, A RI -4T T LIRN / ONLY ON EXIT. PROP. ACCESS AISLE 411' .-4 i "* -1' -I" v.—PROP. �. ��'"• . '`_.� CONCRETE ' HANDICAP c�? � � � `� PARK 1N� w/ \, •r ----.- - ___� =-cam` '�..:�� =-� ►. �-, Ali-# ' ...STOP 1' c EXIST. —EXIST. E- I,�I,�DIG,AI PLANTEIR PLANTER CURBING PARKIN: SIGN 200.00' N20 °08'05 "E 0 /., EXIST. Li ENTRANCE LEXIST. PONER POLE DEMOLISH EXIST. PAVEMENT d BASE MATERIAL AS NEEDED TO CONSTRUCT PROP. LANDSCAPE BEDS. �2_ PACIFIC HIGHWAY 99 ICI ICI ICI ill ill I�I�lil Ijl lil III 1I1 1�1 ICI !�L 1jl fir I' I � I � l ► I ► I I I i I � pupil! 3pi CI I .13 4 5 6 Ii �I Iji � ili`I 7 11 fl3 I NOTE: If the rrlcro €ilmed document is less clear than this notice, it is due to the quality of the original document. 0 1r, ?HS INCH 1 2 (, O e 6Z 8G LZ 9? GZ VZ ' CZ ZZ J lIZ 0? 61 81 41 11111111111111111111lll !lIIIIIIiinif11111111IIIIILiII! 1111+ IIIIIIR1 +,11(LI1111t!1111l1111!l Itl l�lz)i!l ;�illllll(�I111 i 1 iiireasar III�I�IIIIIIIIIIIII�III III�II IIIIiliIIII I! 10 11 M6AEmER11NWY 12. 91 Gl bl el Z1 11 O1. 6 8 L 9 S '7 F z l rtw I 1 111 )).1,111,I61!„1I 9111111-1111 lil!,1111IIiIIIIii 11!11ilj1i11 1►1,111111!1IfIII1I4% 111111 +11111116l!1 1 111 il11111ilithinliiii11 +++lr111111l1 • RECEIVED B"'f i 3 1993 TUKW L.A PUBLIC ', /OAKS; z PIZZA HUT, INC. 9111 EAST DOUGLAS POST OFFICE BOX 428 WICHITA. KANSAS 67201 9972 REGISTERED ARCHJTZCT KENNTH HEIDEBRECHT I STATE OF WASHINGTON /0 : The deign and details disclosed herein ore the ex�;;I-Isive property of Pizza Hut, Inc., and shat! not be copied or repro- duced in whole or in part W1thoul its prior written ©1992 PIZZA HUT, INC. 9111 E. DOUGLAS, LOX 428 WICHITA. KANSAS 67201 0 04.. L1 0 0 (I) PA 00 N') (0 t-- H- H- CC LU () .. , DATE.... BY CHK'D 1/26/93 OMM REV! S') BY CHK'D 0/21/93 OMM " 9/20/93 OM1" I SIV 59 • PLANT SO THAT TOP OF ROOT BALL IS EVEN NIT1 -I FINISH GRADE • PAANT ALL CUTS OVER 1" DIA. 2 STRAND TWISTED 12 GUAGE GAL. WIRE ENCASED IN 1" DIA. RUSE ER HOSE HARDWOOD STAKES _ -- 1-3 STAKES 2" X 2" DR ►vEN (MIN. 18 ") FIRMLY INTO SUBGRADE PRIOR TO BACKFILLING STAKE ABOVE FIRST BRANCHES OR AS NECESSARY FOR FIRM SUPPORT �r _ SAUCER SPREAD /'// SPECIFIED PLANTING MiX -- WATER 4 TAMP TO REMOVE AiR POCKETS TREE WRAP TO BOTTOM OF BRANCI -IES LAP PAPER MIN. 1/3 WIDTH, WRAPPING TO REMAIN MIN. ONE YEAR 2. X 'BALL DIA. ', t TREE PLANTING DETAIL --s!TE2) WEED BARRIER FABRIC FORM SAUCER WITµ 3" CONTINUOUS RIM 0 SPECIFIED PLANTING MIX. WATER 4 TAMP TO REMOVE AiR POCKETS 2" MULCH --ti l� ill— }i1, 1 I {I -Ill 1 11-111 1 =i } i, lFIEH i--{ � 1E111 EI —Ili —' PLACE SHRUB IN VERTICAL AND PLUMB POSITION PLACE A LAYER OF WEED BARRIER FABRIC IN ALL SHRUB PLANTING BEDS LEGEND _ —Yd SHRUBS SHRUB PLANTING DETAIL LANDSCAPE EDGING ! TURF AREA BACKFLOW PREVENT ER PROPOSED IRRIGATION MAIN BLDG. WATER SERVICE DECIDUOUS TREE ' y 2" MULCH INSTALLED — BEFORE PLANTING •a O PREPARE BED AS PER WRITTEN SPECIFICATION i- III ==1 l 1= l 1 i- ;1,11 - -1 i I--II —1 � I— I I j l 1, d 1 i =! 11--11 l --I 1 I� 111 —1 i EEI 11111 — 111�-- 1 =-I 11= } 11 =1 � 11- -111- --111 =1 } 1 = =f 11:.111 =1 I _} 11 =! } 1= 111 -111 — 111E111—z I I IEH I- 1,1 GROUNDCOVER PLANTING 10 1-1 i MUM .otO.: e.a - K LANDSCAPE NOTES 1. NO SUBSTITUTIONS SHALL BE ALLOWED W1TI -4OUT APPROVAL. 2. QUANTITIES IN THE PLANT LIST ARE FOR INFORMATION ONLY. CONTRACTOR SHALL VERIFY. 3. ALI_ PLANT LOCATIONS ARE APPROXIMATE: ADJUST AS NECESSARY TO AVOID CONFLICTS. 4. EDGING SMALL SE VINYL "VALLEYVIEW" OR OWNER APPROVED EQUAL. INSTALS_ STAKES IN ACCORDANCE WITH MANUFACTURER'S RECOMMENDATION. 5. THE PLANTING BEDS RECEIVING MULCI-4 SMALL ESE TREATED WITt -i A F'RE- EMERGENT PRIOR TO PLANTING AND MULCH PLACEMENT. APPLY IN ACCORDANCE WiTH STANDARD TRADE PRACTICE. F,, WEED BARRIER FABRIC, AS NOTED iN THE SPECIFICATIONS, SHALL 5E INSTALLED IN ALL SNRUE3 PLANTING BEDS. -1. REFER TO BUILDING PLAN SPECIFICATIONS FOR APPLICAF3LE LANDSCAPE SECTIONS. 8, SOD TYPE SHALL BE BLUEGRASS, LOCALLY AVAILABLE HARDY BLEND. 9. MULCH SHALL BE SHREDDED HARDV'IOOD MULCH iN LIEU OF TI-1E REDWOOD TYPE CALLED FOR IN TI-4E E3UILDING PLAN SPECS. 10. RE- E5TASLI51 -1 ALL THE AREAS DISTURBED E3Y GRADING OR UTILITY TRENCI -4ING iN THE R.O.W. 11. WHEN CLAY SOIL IS ENCOUNTERED IN THE ESTABLISHMENT OF TkE LAWN OR THE INSTALLATION OF PLANT MATERIAL, SOIL SHALL BE IMPROVED IN ACCORDANCE WITH STANDARD TRADE PRACTICE. Le. ADDITION OF LiME, GYPSUM, ETC. PLANT LIST KEY 1 QTY.. Nr'' COMMON NAME F3OTANICAL NAME DV SA TJ VM 9 41 3E3 313 /ti. tie PLA,11-1- Lt141,:r UV. DAVID ViBURNUM ANTHONY ;'IATERER SPIREA TAM.ARIX SAviN JUNIPER COMMON PERIWINKLE h W4 'RR t, ..� TX �At vIBURNU'I DAVIDI SPiRAEA E3UMALDA 'ANTHONY WATERER' JUNiPERUS SABINA TAMARISCIFOLiA vINCA MINOR .. A. 2 GAL. 2 GAL. 2 GAL. COND. CONT. CONT. CONT. 3" POT CONT. f0 12" O.C. PIZZA HUT, INC, 9111 EAST DOUGLAS POST OFFICE BOX 428 WICHITA, KANSAS 67201 REGiSTEIREO ARCHITECT The design and details disclosed herein are the exclusive property of Pizza Hut, Inc., and shall not be copied or repro- duced in whole or in port without its prior written consent. ©1992 PIZZA HU F, INC. 9111 E. DOUGLAS, BOX 428 WICHITA, KANSAS 67201 MO1- 17'+...Atfr VEITATiON Loy .`Ttr) 0(4 st.OP P \ Si- OW A5 P..l;)ti.,.iw. NM NM J'/I ill.. tti. .Z0-1 ti (71ATIQN. Al k. .11,4ct.A.me PeiorfaijM r s i i 1) QveR_- 1 /T 1,W i 1010 ) ;-.;c116 It c.: w Yh1(1►). 21 • DATE BY CHK'D 9/20/93 OMMV REV!S'D BY CHK'D j ; 1 r 0/'/3 (.��,l��!1 zAN, 1111 111` 111 'ii►�11111IIIhlijil►iljldll(I'I iI'1.1�� 11,;1 11i y3 4 *RS* # .. ":iJ . vet' • 1.1 o-r .' 1 t • 4 FORMATION L M L,E D o N T hH i t t4CLUOSE) Willi iwo mo1a1d C. VE\•EP eviO S AC 'S c,) 'M(2. ) i LAN PSCL ' ._�:I tC ri \'1sEI> loin Jc 6YAE5:, & 111111111 f 11r 11I (' TI` I11I 11111 III Ili' iI 1II1 4a,I.1. i iti 5 6 7 8 ?NOTE' it the microfilmed document is Tess clear than this notice, it is due to the quality of the original document. z !z 03 61 et Gl 96 Gt tit CL Zl It 01, 6 e 111111111111111111111111111 1111,11111,II !11,!111h11111III1,111! IIi1114.,1 111111111b ill- li!I{II�I�I,!�, ,�,iA1111..1 !11111111 11' i IfIj �lllliilllu1 lill!I 1,11! I l i .,.. �. - y,r ,: ^k :, :' t ry''r �;: S = dldwr � !t rJ �' . r:. � � � i„1I11 }}- or( 9.F° , • t3C1 ?ERMIT oeN ",; • A A(11 'C IVED TUKWILA 2 4 1993 ►1,11111I1I111 1111111111111111111111111111111 9 10 11 M-o0., 12. I s!! G fi C e W w O �I 1,11l1111111111.IL1{II1lI•Illi li11111illlllil !IIIIIl111111fIII111I!!1 T CENTER EQUIPMENT SCHEDULE DESCRIPTION ITEM NO. 003 004 012 013 016 052 05 3 0 T7 3 078 08 0 110-1:3 I.,1.10-1,1 111•16 111-226C 111-P3 111-23C 11 1 -24 111 -24C 115-24 131-84 271C 226 2:32 236 242-1 L r P FS 4 4 12 12 20 20 20 PO 20 20 16 16 3 4 1 0 Et LC GAS 61"2.1 61218 61P I 6 61206 ',0912 6120') 0 b 82329 1 61346 846P7 84603 bi.'J't-7? 0 I 6 :-3445 6020" • 63445 60204 60212 63144 6%-). 8 12 60208 60212 62804 62812 60209 60212 62811 62812 63416 60209 60212 60279 1 62441 1 6 8 8 1 1 8 18 4 275-6 311- BWL 1 1 1 1 312 337 371-9W 1 2 60319 60320 208/ I ORAL GAS I I MI: CI TICK 1 TME CARD RACK I I N API') ANAGER'S DLS1< CHAIR 1; INF. I 1- v' I H Yi EiNVF: L fjPr. r K SUP NO. EQUIPMENT SCHEDULE DESCRIPTION SUP INSTALL OVEN 1-1LJOD r NCL ( I) [3L ) , r- 1-- LI k, PX4 WIRE cur TABLE POSIS - 33' U, LricKfrrc, WHELIS SOLID S/S lUP SHLLF W I RE SHELF BEL [1W Ci C r (-1334 ( (S I ( i C I:41111 LT V DL F1 L65 • N1 LAV.A- I 1 CK CASSE-1T [ HP . LC 1. s;.r. c. 5 7 r) 611 OS) 7'i D SAUCL PUMP PASS 1HRU CI R 6 ICKI 1.11 r's11; Nsr . , Pk). s C[1MF=)Li P c.:(“? 'I. Ht. ITEM NO. 824 BP 5 930 •51 933 9:34 A DO PFS # 89254 DESCRIPTION HOT WW—MI X la VALVE 1 95995 1 85994 65453 10 68427 68026 c 0894 IL 93323 1 82979 89973 WTR HTR INSUL JACKET ACCESS cnNT BO" AFT KEYPAD 54° Arr ELECTRIC STRIKE SECORITRON SYSTEM VISION PANEL DETFX P I C Al APM 9111 EAST DOUGLAS POST OFFICE BOX 428 HIC1-4ITA, KANSAS 6.1201 W I AT:1HW I NUS STEPLADIK.P 6 1.. 1. IC AL f.1; L r1..11,' 11!1NS !isrP HLI.iR s r (.; N SLIM 13i'] i. REGISTERED ARCHITECT KENTTHHEIDEMECHT STATE OF WASvIINGTONt 7727-(,3 J RE SOL !..\i 18 POS.! S :33" Li L 60838 61T19 4 0 .')! 0 03 ^,117)± 1-1)'i ' Dr E. PriSI [ft 1) f_ D WIRE SHEL V 18' / P1.1 S - 33' C 2 6091 G.L. WIRE SHLLV 18 X 6 ' PDS i S - :'4 ' Li G.C. Li G.0 6 WR SHLL V 2 ' X30' CHAI POSTS - 74 " COAT L D W 1 RE. SHEL V >t, POS1S - /4 LI C I 8:1)9 1 60506 1 61269 L co w1N Li SIGN ( 3 ) CLIMP S I N1K mnp HANG* R LJ C . 831 221 832 (9.14 The design and details disclosed herein are the exclusive property of PIzz.a 14ut, Inc., and-shall not be copied or repro- duced in whole or In part without its prior written consent. 01993 PIZZA 141.1T, INC, 9111 E.DOta-AS, BOX 428 HIC1-11TA, KANSAS 61201 1-1 O G C C], G C EQUIPMENT SCHEDULE 60323 61222 61212 61303 62731 81197 87754 68685 86296 86775 63384 60401 61256 67557 85370 85369 WR SHE V 2' X 3 ' COAT FOS 7 S • 74 ' COAT WIPE. SHLLV 2 ' X 4 PH,.; TS -- 74 ' WR SHE L V 2 ' X 4 ' COAT POSTS - 74 ' COA T DUNNAGE 'c'.Y X 4 WIRE SHEL V 2 ' X 4 POSTS - 74 S/S WALL SHELF 14' X 84' MIXER (230/3) DOUGH SHEETER STATIONARY PROOFER WR SHEL V 2 'X2 ' CHAT pnsTs - 74H COATED CASTERS ROLL -1N RE TARD (LH) ° " MAKETABLE - LEFT S/S OVERHEAD SHELF INSERT PANS 1/4Y6 I NSER T PANS 1 /2X6 I NSERT PANS FULL X 8 DOUGH SHTR rI3L (6 ' ) OVEN BLOD WIDE (DBL) LEFT--HAND FEED START-UP KIT INSTALIATITTN KIT PASTER DRAWER SLIDES (SETS) HO T PI A IF CORD SE T OVEN HOOD - 9' EXH. FAN MAKE-UP FAN n. G.E c , VEND = VENDOR C.C. = GENERAL CONTRACTOR FILL EXISTING WINDOW OPENINGS TO MATCH EXISTING EXTERIOR WALL CONSTRUCTION Il G C H. G.C. LI H. ii 1:1 Li ii LI . O. C.) C G.C. G.C. G.E. G . C . G C ITEM NO. _032 075 _,--F14C. EXTINGUISHER 162 BEVERAGE COOLER_ 538 RECIEPT PRINTER 540 DISPATCHTERMINAL_____ 542 ORDER ENTRY TERMINAL 543 CASHOUT TERMINAL 545 REPORT PRINT W/STAND 546 ORDER PRINTER 556 CASH DRAWER 5770 SUS CENTRAL PROCESSING UNIT 685 TOILET SIGN (MEN) -- 686 TOILET SIGN (WOMEN) 782 MOP SINK . (RE: MECH.) 811 WATER CLOSET (RE:_ MECH.) _ LAVATORY _ _ (RE: MECH) _81_4_ HAND__ SINK (13.E.:” MECH.) 820, WATER COOLER PE: MECH. 822 WATER „ HEATER _ (RE: M E_C H.) 823 GREASE TRAP 831 SOAP DISPENSER 832 TOWEL DISPENSR , C.C. 838 MIRROR j 0.0. 841 TOILET TISSUE DISPENSER 1 G.C. 844 NAPKIN DISPOSER G.C. 847 CRAB BARS , G.C. 871 ELECT DIST PANEL (RE: ELEC.) 873 TELEPHONE TERMINAL BRD.(RE: ELEC.) G.C. 876 WALL. TELEPHONE VEND 877 DESK TELEPHONE VEND 890 TELEPHONE EQUIPMENT VEND DESCRIPTION SUPPLY INSTALL COAT HOOKS G.C. C.C. G.C. VEND VEND VEND -V615_ _ VEND__ VEND VEND VEND VEND VEND _VEND VEND __C/CND___ VEND VEND VEND VEND VEND G.C. C.C. G.C. 0.0. G.C. G.C. G.C. G.C. G.C. _0.0. G.C. G.E. G.C. G.C. G.C. • SECURITRO PANELS er-eL — EXISTING COLUMNS obt 841 847 G C G.C. EXISTING COLUMNS 877 931 545 EXISTING RESTROOM RELOCATED FIXTURES G:C. C.C. C.C. G.C. G.C. G'.C. VEND VEND 1 VEND CARRYOUT NEON VALANCE ABOVE New DOOR IN EXIST, OPTNIN Eft*" G.C. .—_CE. TO vaitiFr NEN COOLER/PREEZER UNIT6 1_1 • C Li • - • , • ST.,?;(' Y. ).. • r , 0 MMSINCH 1 2 • IlitiONIP111-11"P"1 till I 1111.11111111111['[� 111111114f1t144111 4-1-,111111111111111 I IIIIIII 9 • • 10 It '4," ""ERMAMY PROPOSED EQUIPMENT PLAN GROSS ARCA: 2016 SF RECEIVED CITY OF TUKWILA, SEP 2 4 1993 1/4" 1)-0" PERMIT CENTER o4t/3 4 5 6 1:7_ -- 1 ; , . NOTE: If the microfilmed document is less clear than this . 1 , notice, it is due to the quality of the prigin!I docu!ent, t Oe 6Z ee LZ eZ .cZ 17Z ' CZ ZZ tZ 07.1 et et Ll 91 `;'t tt E:i Zl. IL OL 6 11111111111111111111h11111111111111111111111111111111111111111111Fati 11[1111illinlilliqlijj111)11.11,41;11.11P.1.11114111,1111U.M.AL 1111114ki)J11414111A110.111J11.1.1,1111,1.10,111,11111IndIngt11,11,11111 1 1 1 i ' ' . ' ' • ' . - - '''''' " -'1-'':'.'")"1',.'',";:;;•;-',43'k''.:'-'.":*,':-.-:-/.,-..-,.;-:-;..,,-,,t;:':-:.-.`'".; .-::,' - .:..'.`,. - ".. .., ' ' --'04.,,t:lf, ,. ' • , - .,:, , ' / :.':'-: • F . • I "VI 0 • •, • - • • • 1,11111 II 1 4 WIESE !_PCUEDUJJ9P SCHEDULE 5/8" 2" 5/8" FRAME (FR 1) FRAME 2 (FR 2) DOOR SCHEDULE EXTERIOR DRIVIER EXIT INTERIOR TOILE' I INTERIOR R eeG!ltrrY REAR EXIT 0 - PLYWOOD e • eXi9TIN9 MATERIAL I" • i'RP PANEL ST- STAINLESS O • GYPSUM BOARn P • PAINTED SC- SPec AL %'iG S - SUBPrNDeD ..:;ID & TILE T _ VINYL FLOOR TILe CT- CERAMIC TYLe QT- QUARRY TILE U • UNFINISHED W • WATER RESISTANT GYP, BD. x - RESISTANT GYP. BO. wHeN MULTIPLE 9YMboLS ARE GIVEN, THE F'1RST INDICATES THE FIRST LAYER, THE SECOND INDICATES THe SECOND LAYER, ETC. QUARRY T1Le BASE TO BE CONTINUOUS IN ALL FINISH AREAS. Gt.ASS WRY WITH S1DR41TR•a r INCA. °LABE' 3'- ti*o, -t3'xt 3/8' Ili DOOR /FRAME 3'- 6`x7' - >Pxt 3/3' HM DDOrt„[FR AKE MANI .,A SEt U?TRON SkITCk 5 --LOCATION.. RE: ELEC. r 9 -A5 CAsHot t TERMINAL— SAFE sAcKLAT---f fop MHG RE: 2 -AS 1 IV ra ot"t1ET 14..E FOR ELEC. DESK P1IO1NE REPCOIT PRINTER 614ELVING, OELON — (.t-rR OF 3) 1 Ci$I : ar± . • -1 texctusivo pnop6rts.of • P1174a , A, ;t not be copleapla ,respro- Ouced p-, In I i ("4'411 part; alait °lx ut• • its . ktrj t a Vii@. ; try tt' O ivi 4 fait, 160X 426 1 FILL EXISTRNCs Y+ION I A SA PUMP; F Fee: 1- 12 �'"""' to a 1 ORDER ENTRY DEVICE (TYP OF 4) TELEPWONE INSERT (`t" Yf OF 4114E: 4-.0 KALI- TELEVII4C'NE (Tro. a 4) DCP EXISTING; COLLMN.S IL PE212 oto IP EXISTING COLUA"t:B 2' -6' VALANCE -- ABOVE 9 -A5 OVEN HOOD 1 ENCLOSURE SYSTEM-Th. te I :1 -A5 1^ 5 " FINE•RATt; PARTITIONS \ —__-- ENLARGED COUNTER PLAN 112" le 11-08 II' -6.1'G ti 1TLIR 1`"x1" CORNER MA FULL K.I. H�► T tEigteyi PROVIDE NtN -8Lfl MUSH f f 11 i 1 =tai WittiFY �dCT K E)t - VERIFY HALL NICKI\ESS T'Q I etER 511 E rtaxm moue J,r ! ...._... _-. 2 ' • `_" PROVIDE !WRONG ACIMT 1M 11404 5E CONciRETE APPLY I tfl� TO 51De Orr coasoz E4 RAMP • STORAGE 1/2" .* 11 -Qk MOMMMORMWMOM IIMIGINSEMESEIERN GIRREI �t1s1.44r�s l Ijl l Ijl j Ijl l Ijl l I{I l I(I l Iji II jI lI if !I (l II ' jI lIi! lI aI lI ►I II jjr l ' 1I � 4tWAW.J�II (I eSe 141.11. fck , d�. ifiva ?4f+, 1/4?44s4rsu�i :4bl4dd; 7.. ti:e!:, : r�_�ac Jl . 1 I iI jI1I Ii ( 11 1(V (I I I(I I I(f I f(I l f(. 1111111111-111101111 II .�{ I I. I lf (I: i(f1 III 1i,i l I(i1ll 1 liI I(I1 I(! 1 i1 y f " ... 0 I6 TH3 INCH 1 2 ?W 3 4 a 6 7 8 9 10 11 WLEINGERNANY 12.: r NOTE: • If_ the microfilmed document is less clear than this > ( -notice, it is due to the quality of the 7riginal document. I • - ! 0€ 6IZ 8G LZ ti?.. SZ 4iIZ CZ ZIZ to 0-e 61 8t Lt 9t St +7l Et Zl It dl, 6 8 L ; 9 S IIIII IIIIIII1111111II11 1111IIII1111111I 1111111111 1111111H )11111i1911lil�llll1;.11 101111l�! ;�� 41J1fl,1j1(111111111 i IIIliIIILINIIl{II 11111f11 �lU,IIIIIII IIIIIIIIIIIIIIII{111! .1111! �IillIlli li li Ili tiilllllil!IIIIIIil11111 c Z t yin 0 1! 11111 1111! IlIIIIIIIIIIllllllfiiil v:. \ \ WRY WITH S1DR41TR•a r INCA. °LABE' 3'- ti*o, -t3'xt 3/8' Ili DOOR /FRAME 3'- 6`x7' - >Pxt 3/3' HM DDOrt„[FR AKE MANI .,A SEt U?TRON SkITCk 5 --LOCATION.. RE: ELEC. r 9 -A5 CAsHot t TERMINAL— SAFE sAcKLAT---f fop MHG RE: 2 -AS 1 IV ra ot"t1ET 14..E FOR ELEC. DESK P1IO1NE REPCOIT PRINTER 614ELVING, OELON — (.t-rR OF 3) 1 Ci$I : ar± . • -1 texctusivo pnop6rts.of • P1174a , A, ;t not be copleapla ,respro- Ouced p-, In I i ("4'411 part; alait °lx ut• • its . ktrj t a Vii@. ; try tt' O ivi 4 fait, 160X 426 1 FILL EXISTRNCs Y+ION I A SA PUMP; F Fee: 1- 12 �'"""' to a 1 ORDER ENTRY DEVICE (TYP OF 4) TELEPWONE INSERT (`t" Yf OF 4114E: 4-.0 KALI- TELEVII4C'NE (Tro. a 4) DCP EXISTING; COLLMN.S IL PE212 oto IP EXISTING COLUA"t:B 2' -6' VALANCE -- ABOVE 9 -A5 OVEN HOOD 1 ENCLOSURE SYSTEM-Th. te I :1 -A5 1^ 5 " FINE•RATt; PARTITIONS \ —__-- ENLARGED COUNTER PLAN 112" le 11-08 II' -6.1'G ti 1TLIR 1`"x1" CORNER MA FULL K.I. H�► T tEigteyi PROVIDE NtN -8Lfl MUSH f f 11 i 1 =tai WittiFY �dCT K E)t - VERIFY HALL NICKI\ESS T'Q I etER 511 E rtaxm moue J,r ! ...._... _-. 2 ' • `_" PROVIDE !WRONG ACIMT 1M 11404 5E CONciRETE APPLY I tfl� TO 51De Orr coasoz E4 RAMP • STORAGE 1/2" .* 11 -Qk MOMMMORMWMOM IIMIGINSEMESEIERN GIRREI �t1s1.44r�s l Ijl l Ijl j Ijl l Ijl l I{I l I(I l Iji II jI lI if !I (l II ' jI lIi! lI aI lI ►I II jjr l ' 1I � 4tWAW.J�II (I eSe 141.11. fck , d�. ifiva ?4f+, 1/4?44s4rsu�i :4bl4dd; 7.. ti:e!:, : r�_�ac Jl . 1 I iI jI1I Ii ( 11 1(V (I I I(I I I(f I f(I l f(. 1111111111-111101111 II .�{ I I. I lf (I: i(f1 III 1i,i l I(i1ll 1 liI I(I1 I(! 1 i1 y f " ... 0 I6 TH3 INCH 1 2 ?W 3 4 a 6 7 8 9 10 11 WLEINGERNANY 12.: r NOTE: • If_ the microfilmed document is less clear than this > ( -notice, it is due to the quality of the 7riginal document. I • - ! 0€ 6IZ 8G LZ ti?.. SZ 4iIZ CZ ZIZ to 0-e 61 8t Lt 9t St +7l Et Zl It dl, 6 8 L ; 9 S IIIII IIIIIII1111111II11 1111IIII1111111I 1111111111 1111111H )11111i1911lil�llll1;.11 101111l�! ;�� 41J1fl,1j1(111111111 i IIIliIIILINIIl{II 11111f11 �lU,IIIIIII IIIIIIIIIIIIIIII{111! .1111! �IillIlli li li Ili tiilllllil!IIIIIIil11111 c Z t yin 0 1! 11111 1111! IlIIIIIIIIIIllllllfiiil v:. IME1111115111121B2111111E1819111MUNIMIM EZESESIMBEIN 113314111EMBIZMINedd . , .. . . . . . LEGEND G HVAC GRILL 5:2 EMERGENCY LIGHT IS EXIT LIGHT T*--;3--' L„,----.1"--..,,,, 21x4.' LAY IN riLUORESCENT PIXTURE KEITMTH STATE oF wASHI,IfITQN 2X4 LAY IN FLUOR FIXTURE. REc ELEC. Tivi deal d and okstelio' .: dIsoloo • - Nreln arcif tits . excloMe properji or • PI2241 kft,,a10„ IS ' ehali • not be =pled or .repro-' aced RI Kirld or In paii, yothm Its.prIor 0TItter (01,4.1 fnii,4 1.4.Pr, 64C. , 41111 E-'00141.A6,' '. SOX 428 ' • • :,, A IllcurrA KANSAS irpTlifi NOtE; PROVIDE, #12 *GA. WIRES AT ALL .P'OUR CORNERS , OF LIGHT FiXTuRE cc. DIFUSSERS.,1yEl: . I5ACKLIT AMING IVE$ 242, • LAY-11/ Poarts sHout.o oE-SECURED IN PLACE 61'1. CLIPS WHEN ASSEJABLY RE- - WIRES A FIRE RESISTANCE MTING; ALSO ',ANSI Lone our 10 PRESSURE DIFFERENTIAL. • • • • FIXTURES GENERALLY HAVE mAIN RUNNER TO DE BOXED-it4 tOR FIRE • RESISTANCE RAMC: FRE Duct,AND . DAMPERS MUST BC PRO, MODULAR VIDEO AT ALL 0,PENms. orrrusER • • SUCH AS DIFFUSERS. SECONDARY • • SUPPORT • HANDERS sicutteo TO FRAMING MEMBERS, STRUCTuRAL DECK, BR TO SECOnDARY MANG. SYSTEM. • • FIELD CUT • • TILE . SUSPENDED CEILINO.. LATER/4. FORCE DRACINO WHERE SUBSTAITIATIP DESIGN CALCS ME NOT PROVIDED, HORIZONTAL RESTRAINT SKIkli, OE crFECTED SY 'FOUR•112 c WIRES SECURED TO . , THE MAIN RUNNER WITHIN 2" OF ME CROSS RUNNL'it INTERSECTION • AND SPLAYED 90' FROM EACH OTHER 4 • A? AN ANCLE NOT EXCEEDING 45' FROM THE PLANE or THE CER.410.* -1' THESE HOF110i1FAL R;;SlINF ' • P0'143 Pik!, PLACED 12' ON CEktTER 114 00TH DIRECTIONS.WITH _ THE FIRST POINT W111144 4' rRom , EACH WALL arActimort -OF ThE' • RESTRAV WIRES TO 'THE.STRUC TURE ABOVE SHALL OE ADEQUATE • FOR THE LOAD IMPOSED, NOTE: WeirkwOJACENT WALLS TO COUNDS CROSS k/OR WI RUNNERS, 2'4 4'4 $/ T-OAR CER1/10 NO. /DX EXPOSE* TEE SYSTEM, BY OONN CORP. • OR AMMO EQ. NATURAL FISSURED WATI EWE TRIM 3/11" kiIN. CfrOSS RUNNER Ofi MAIN StUNtitti 012 PAUCC Wat g‘iL f.,*t' EMERGENCY LICINT RE1 ELEC (TYR OF 5) 2X2 VINYL PACED TILE ARO te4ITE GRID PER 61126C. NINE4T1074 MOIMIMEIBMI N1SICESSZEIC ,,:::tiiiiiA4u014-e.yezii,--ikte&s.,414,..461s,,ciekikiiiii•ik.,7.,,,. IIIIIIIIIIIIIIIIIIIIIIIIIIIIIIII11111111111111111011111111[PM11/11 1 i • ' 1 ' 1 ' 1 ' 1 0 16 TF1S INCH I 2 /t4u1 3 4 5 6 7 8 I_ .._. . _. ._ _ ........... _ __.. ' NOTE: If the microfilmed document is less clear than this notice, it is due to the quality of the •priginal document. =TR ,tort„firrqm 06 63 se ZZ 93 GZ •173 ez 0-e 6L En LA 61111416666"64444441614*0664WRIA _it.4.-ibigigiwagglikiiihWifikoki.:-4, Ilrli1111111111111!1111111111111111111111111111111 1 I 1 . 1 9 10 11 KA0E,Nos....., 12, 1? 9L GI in CIL Zt U pi, 6 8 L. 9 G "" w1.040WIA0014.14110116044A0411H4444411111,1116141111 RIIMINOMPRIORIU! WPM 4 MOMS It -' - -- rillistlini l.rig. 1 illi t1' fit" ',� *umaia•••. : f LAT IN CLG. N RE: SPEC. gel if PANEL cn 6x6 CERAMIC TILE RE: FINISH SCHEDULE 5/8" GYP. BRD. —2x4 WOOD STUD HEADER SEALANT EA. sl:)E i I 1 I i I!( t�r IN t MTh (1W COAT 14000 SOFEH TO HALL PROVIDE ADECLIAIE BLOCKNG (E''4tAPIEL PAN) COAT HOOKS DETAIL 30 SCAB CASH DRAWER DETAIL 111 "AI' -;" ..-------HOLLOW METAL FRAME (FR 1) RE: DOOR SCHEDULE STAINLESS STEEL STOVE BOLTS (rrP. OF Se) .. ..........a.�. ELEVATION FOR RELATIVE PLACEMENT co INDICATED ITEMS - R13rER TO ENLARGED =INTER PLAN FOR EXACT PLC OF EC,7JIP ETN 4 EXTENT OF OvERS4ELF CASHOUT ELEVATION .. .. 1111 " 11.0... SECTION 9111 EAST POU Los POST OFFICE BOX 426 fr4!CI -IITA, KANSAS 61201 3" ," 11 -031 MOCKING BY G.C. (rm.CF2) - F.R,P, PANEL 5/8" GYP. BRD. 2x4 WOOD STUD —CASH DRAAER BY VENDOR (ME: EQUIP. PLAN FOR LOC) DISPATCH CASH DRAWER NO SCALE NOTES: ALL AWNING PRAMS MEMBERS SHALL BE 1 "x1 "x1 /8" EXTRUDED ALUMINUM (6061 -T6) TUBES UNLESS OTHERWISE NOTED. AWNING FABRIC SHALL BE #2285 SIGNTECH GLOSSY RED GLASSKOTE #1 ENIVETH H IDEBRECHT STATE OF WASHINGTON 2x BLOCKING WELDED JOINT (TYP. ALL LOCS.) ,,---- SEALANT EA. SIDE (FOLL R 1) OW METAL FRAME : •' JAMB ANCHOR MOUNTING BA -1 - --'- -- DOOR 1 ,( RE: DOOR SCHEDULE TYPICAL INTERIOR DOOR JAMB n • 11 -0" BRACE PARTITION TO STRUCTURE AT 4' -s " O�G. ALTERNATIN WOdi, PLATE OR METAL STUD TRACK CONTINUOUS RE: SF4T. Al -MOUNTING FRAME BY AWNING MFR. CONT, BETWEEN EXIST. COLUMNS - SECURE TO EXIST. STRUCTURE AT 3' -0" MAX. �.- -- -2x4 WOE STUD FRAMING AT 16 O.G. WITH PAINTED GYPSUM BOARD - LIGHTED MENU BOARD PROVIDE BLOCKING AS REQUIRED FOR SUPPORT -- DASHED LINE SHOWS ALTERNATE LOCATION --TILE BULLNOSE AT EXPOSED EDGE S//3" GYP BD. 1e: SW. A2 FOR FINISHES CAULK JOINT 2x4 EYED 2x4 ME BRACE AT 4'-0" OC. TYP 3.d TYP.AT EA. END OF nee BRACE 2x4 ND. STUD FRAMING AT IV" 0.C. MN $/8" GYP. BD. At4D FRP BACKER ROO t SEALANT Ce RRFE ll PROVIDE 1 /2" ALL- THREAD HANGERS, ONE "; IIL: AT EACH END OP MENU bOARD. SUSP NPEID ACOUSTICAL CEILI1,41 4 GRID PER SPEC 1 1-IR, FIRE RATED WHEN NOTED RE: S.1T. Al CLIP DETAIL NO SCALE NEW PARTITION AT CEILING VALANCE SECTION AT MENU BOARD SIMILAR .'/ FRAME PLAN 1/2" a 11 -0" METAL STUDS 91.40h4s1 THUS IN PLAN }A OD STUNS 5440141 TI-UJS IN PLAN SPACER-) AS REtI'D. MOUNTING BAR 11101/41/8" ALUM. 0 TUBE 11-6" O.C. Z -CLIP AT TOP AT 3' -O" O.C. MAX. (See DETAIL) 1" x1"x1 /8° ALUM. 0 TUBE 51-0" O.C. FLUOR. FIXTURES RE: ELEC. CONTINUOUS HORIZ. 1"x11/41/S" ALUM. a TUBE MEMBERS TOP & BOTTOM CONTINUOUS 1/2" DIA, TIE -BACK ROD AT TOP & BOTTOM SECURE TO EXIST. CONSTRUCTION AT 5' -O" O.C. MAX. 74(2.0— The clesl n and desitti s disclosed fain area the exclusive property of Pixz8 Put, Inc., and Shall not be copied or repro» cluceea In Mole or In part Nithout its prior pritten consent. ( 1993 PIZZA I4UT, INC: 1111E. DOUGLAS, BOX 421 I410-1ITA, KANSAS es '12401 TYPICAL SECTION ail , v -o" VALANCE AT COOLER V —1011 1441TE NEON 2.x4 KNEE BRACE AT 4' -4" O.C. TYP. f- --- IS.HNTGT'S.ISALL MOUNTING LUGS IN VERT. GROUT JOINTS RE: INTERIOR ELEVATIONS FOR LOCATIONS 2x4 WD. mt.) FRAMING AT 16" O.C. WITH GYPSUM BOARD 6X6 RED CERAMIC TILE WITH BULLNOSE AT LOWER EDGE AWNING bETALS SCALE AS NOTED 2 HOUR METAL STUDS 61-10i44 THUS IN PLAN HOOD STUDS 6W01+1 THUS iN i 6AN FACE OF HALL P -LAi 1. COVED ENOS 3/4" PI.YNO. OVE `" dELF Wi14 P- LAi"1. EA. SILK FRP PANELING - t ON GYP. BD. CAULK JOINT VALANCE SECTION AT NEON IH • 11 -043' NEON DETAIL I LAYER TYPE 'X' GYP? SD. EACH SIDE I HOUR RAJQ FIRE RATED PARTITIONS RE: FLOOR PLAN FOR FRAMINCs TYPE NOT TO SCALE wig mire1' ON nfl wennn 12mm WHITE NEON LIGHTS. INSTALL MOUNTING LUGS IN VERT. GROUT JOINTS RE: INTERIOR ELEVATIONS FOR LOCATIONS 2x4 WO. STUD FRAMING AT 15" O.C. WITH GYPSUM BOARD 6X6 Re() CERAMIC TILE WITH BULLNOSE �r-AT LOWER EDGE BOC.CURS S'-10+1 BE PAINTED E WALLS BELOW TO P- I.N1. AT ALL EDGES 4Tart MONITOR KEYQ49 D 1)0 ECG 4 1X3 !LOCKING - CUT I -I/24 WOLE IN COUNTER FOR ELECTRICAL AT P14CNE INSERTS TYP. LOCATION! OF EL C. REr4'PPlC TAL 2' 4)" d J". 9/4" Pi4CNE WERT REMOVABLE PHONE INSERT OF 3/4" PL11/17. KITH P-LAkt ON EXPOSED SIDES a cx ... (RE: DETAIL) RE: ENLARGED ���C�OUIsI�TER � t� PLAN FOR EXACT LOCATIONS PROVIDE HOOD EL KO IN hf,ALL AS i &2`tJJ. TO SECURE BRACE ANGLE 2 1/2 "x2 I/2"x3/I6" ANGLES AS NEEDED. SELO AT 0 TO SUPPORT TOP. PAINTED b4IITE, i PROVIDE STIFFENER AS NECESSARY 3' -O" A.C. MIt+I, CASH MAKER 4 2x4 STUDS AT 16' OC WITS# Sir CsYP. BD. EA. SIDE 4 i D CERAMIC TILE PER SPECS DATE . Bl° 1.44.93 0711W VISED PHONE INSERT DETAIL NOT TO SCALE ANC 2 :{ AT R .00R SECTION AT COUNTER NOTE: RFJER TOENLARGED COUNTER PLAN FOR EXACT COWAURATION AND EXTENT OF OVERLF. • !o-r „y` ,y .o?fSaif�" .,.- .a ..... .,,..;,,, ¢zkb �";i• ;,,fi,• ,,. ������� �yy�,:�iyr��f,..�,;{�)���sJ.;'' ! .' �. -. :..:� I:��X' r. .: .t171�-0" k1GlA ...aa } -., �p - 4 =' IIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIITIlillifI�fi '�ifil' [111111111x1 111:111! Irti11111111j1111! 11111111P111141.144111111 1 1, 401111111111111III !1!11111111111i1IIIIIII '. 0 16 INS Ir4CH 1 2 �/ /3 4 5 6 7 $ 9 i 1 0 11 MADE IN GERMANY 12., NOTE: If the • microfilmed document is less clear than this . I notice it 1s due to the quality of the >�rigina). document. 0 do 6Z 8C LZ 9Z SZ ire. 7 CZ ZZ IZ 0?Z 6l 81 LI 1I1111111I!III!11 111111II1I111111111111111111111110iI !)I�I111Rdlil ilJ 1Jl1-i!!!lhM,11�j ;11I1)11111111111`I!! !!L' 9l gl bl £l Zl LI. 01, 5 8 G 9 .9 +J C ? I ww 0 JIII 11114 {,illy ill,��,!�Illii! �!Il !! 1,.1;,,.11111 Iijl,:!I)1„l11,!I!i i,llll!11.�1,I�R1111 fl,llil�f Il; Ilil! I, IfII. 1, llllllillllil !!!i,i!!!,!I!!1!Iil�