Loading...
HomeMy WebLinkAboutPermit D06-259 - Seattle Chocolates - Storage RacksSEATTLE CHOCOLATES 1180 ANDOVER PK W EKPII?ED 07 - 10 - 07 D06 -259 Parcel No.: 3523049085 Address: 1180 ANDOVER PK W TUKW Suite No: Tenant: Name: SEATTLE CHOCOLATES Address: 1180 ANDOVER PK W , TUKWILA WA Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http.• / /www.cLtukwila.wa.us Owner: Name: GCC -LCC Address: 1180 ANDOVER PARK W , TUKWILA WA 98188 Phone: Contact Person: Name: MIKE SORENSON Address: 1100 SW 7 ST , RENTON WA 98056 Phone: 208 818 -4488 Contractor: Name: NORTH WEST HANDLING SYSTEMS INC .Address: 1100 S.W. 7T11 STEET , RENTON, WA 98055 Phone: 206255 -0500 Contractor License No: NORTH W H275JF Value of Construction: $0.00 Type of Fire Protection: SPRINKLERS/EXT Type of Construction: Citysf Tukwila DEVELOPMENT PERMIT Permit Number: D06 -259 Issue Date: 07/14/2006 Permit Expires On: 07/10/2007 * *continued on next page ** Expiration Date: 10/09/2007 DESCRIPTION OF WORK: INSTALLATION OF NEW PALLET RACKING FOR STORAGE OF CHOCOLATE CANDIES IN FOIL & PAPER WRAPPERS STORED IN CARDBOARD BOXES ON WOOD PALLETS. ALSO STORING FLATTENED CARDBOARD ON WOOD PALLETS, NON ENCAPSULATED. Fees Collected: $1,255.22 International Building Code Edition: 2003 Occupancy per IBC: doe: IBC-10 /06 D06 -259 Printed: 04 -26 -2007 Public Works Activities: Channelization / Striping: N Curb Cut / Access / Sidewalk / CSS: N City cos-Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us Fire Loop Hydrant: N Number: 0 Flood Control Zone: Hauling: N Start Time: Land Altering: Volumes: Cut 0 c.y. Landscape Irrigation: Moving Oversize Load: Start Time: Sanitary Side Sewer: Sewer Main Extension: Private: Storm Drainage: Street Use: Profit: N Water Main Extension: Private: Water Meter: N Permit Center Authorized Signature: A W,p6A Permit Ntunber: D06 - 259 Issue Date: 07/14/2006 Permit Expires On: 07/10/2007 Date: Size (Inches): 0 End Time: Fill 0 c.y. End Time: Public: Non - Profit: N Public: o /0 I hereby certify that I have read and dqcatfuned this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction • the pert • • of work. I am authorized to sign and obtain this development p rmit. Signature: , � Jlt Date: if U Print Name. / do !l I O (✓l 9 S- 0 ✓\ This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. doe: IBC-10 /06 006-259 Printed: 04 -26 -2007 � City of Tukwila Department of Community Development / 6300 Southcenter BL, Suite 100 / Tukwila, WA 98188 / (206) 431 -3670 Parcel No.: 3523049085 Address' 1180 ANDOVER PK W TUKW Suite No: Tenant: Name: SEATTLE CHOCOLATES Address: 1180 ANDOVER PK W, TUKWILA WA DEVELOPMENT PERMIT Owner: Name: GCC -LCC Phone: Address: 1180 ANDOVER PARK W, TUKWILA WA Permit Number: D06-259 Issue Date: 07/14/2006 Permit Expires On: 01/10/2007 Contact Person: Name: MIKE SORENSON Phone: 206 818 -4488 Address: 1100 SW 7 ST, RENTON WA Contractor: Name: NORTH WEST HANDLING SYSTEMS INC Phone: 206 255 -0500 Address: 1100 S.W. 7TH STEET, RENTON, WA Contractor License No: NORTHWH275JF Expiration Date:10 /09/2007 DESCRIPTION OF WORK: INSTALLATION OF NEW PALLET RACKING FOR STORAGE OF CHOCOLATE CANDIES IN FOIL & PAPER WRAPPERS STORED IN CARDBOARD BOXES ON WOOD PALLETS. ALSO STORING FLATTENED CARDBOARD ON WOOD PALLETS, NON ENCAPSULATED. Value of Construction: $0.00 Type of Fire Protection: SPRINKLERS /EXT Type of Construction: Public Works Activities: Channelization / Striping: N Curb Cut / Access / Sidewalk / CSS: N Fire Loop Hydrant: Flood Control Zone: Hauling: Land Altering: Landscape Irrigation: Moving Oversize Load: Sanitary Side Sewer: Sewer Main Extension: Storm Drainage: Street Use: N N Water Main Extension: Water Meter: N doc: Devperm Fees Collected: Uniform Building Code Edition: Occupancy per UBC: Number: 0 Size (Inches): 0 Start Time: End Time: Volumes: Cut 0 c.y. Fill 0 c.y. Start Time: End Time: Private: Public: Profit: N Non - Profit: N Private: Public: $718.79 006 -259 Printed: 07 -14 -2006 doe: Devperm City of Tukwila •* Continued Next Page ** Department of Community Development / 6300 Southcenter BL, Suite 100/ Tukwila, WA 98188 / (206) 431 -3670 D06 -259 Printed: 07- 14-2006 City of Tukwila Department of Community Development / 6300 Southcenter BL, Suite 100 / Tukwila, WA 98188 / (206) 431 -3670 Permit Center Authorized Signature 1 hereby certify that I have read and ordinances governing this work will b: • omp The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the pe ocmance of work. I am authorized to sign and obtain this development permit. Date: / /y/O 6 doe: Devperm Signature: Print Name: 0Pen -7.50n Date: 1 1 is permit and know the same to be true and correct. Alt provisions of law and with, whether specified herein or not. This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. 006 -259 Printed: 07-14-2006 Parcel No.: 3523049085 Address: Suite No: Tenant: doc: Cond -10 /06 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us 1180 ANDOVER PK W TURN/ SEATTLE CHOCOLATES 1: ** *BUILDING DEPARTMENT CONDITIONS * ** 9: ** *FIRE DEPARTMENT CONDITIONS * ** PERMIT CONDITIONS Permit Number: Status: Applied Date: Issue Date: D06 -259 ISSUED 07/05/2006 07/14/2006 2: No changes shall be made to the approved plans unless approved by the design professional in responsible charge and the Building Official. 3: All permits, inspection records, and approved plans shall be at the job site and available to the inspectors prior to start of any construction. These documents shall be maintained and made available until final inspection approval is granted. 4: All construction shall be done in conformance with the approved plans and the requirements of the International Building Code or International Residential Code, International Mechanical Code, Washington State Energy Code. 8: All rack storage requires a separate permit issued through the City of Tukwila Permit Center. Rack storage over 8 -feet in height shall be anchored or braced to prevent overturning or displacement during seismic events. The design and calculations for the anchorage or bracing shall be prepared by a registered professional engineer licensed in the State of Washington. 6: There shall be no occupancy of a building until final inspection has been completed and approved by Tukwila building inspector. No exception. 7: Manufacturers installation instructions shall be available on the job site at the time of inspection. 8: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. 10: The attached set of building plans have been reviewed by the Fire Prevention Bureau and are acceptable with the following concerns: 11: The total number of fire extinguishers required for an ordinary hazard occupancy with Class A fire hazards is calculated at one extinguisher for each 1,500 sq. ft. of area. The extinguisher(s) should be of the "All Purpose" (2A, 20B:C) dry chemical type. Travel distance to any fire extinguisher must be 75' or less. (WC 906.3) (NFPA 10, 3-2.1) 12: Portable fire extinguishers, not housed in cabinets, shall be installed on the hangers or brackets supplied. Hangers or brackets shall be securely anchored to the mounting surface in accordance with the manufachuefs installation instructions. Portable fire extinguishers having a gross weight not exceeding 40 pounds (18 kg) shall be installed so that its top is not more than 5 feet (1524 nun) above the floor. Hand -held portable fire extinguishers having a gross weight exceeding 40 pounds (18 kg) shall be installed so that its top is not more than 3.6 feet (1067 mm) above the floor. The clearance between the floor and the bottom of the installed hand -held extinguishers shall not be less than 4 inches (102 mm). (IFC 906.7 and WC 906.9) 13: Fire extinguishers shall not be obstructed or obscured from view. In rooms or areas in which visual obstruction cannot 006 -259 Printed: 04 -26 -2007 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us be completely avoided, means shall be provided to indicate the locations of the extinguishers. (IFC 906.6) 14: Extinguishers shall be located in conspicuous locations where they will be readily accessible and immediately available for use. These locations shall be along normal paths of travel, unless the fxe code official determines that the hazard posed indicates the need for placement away from normal paths of travel. (IFC 906.8) 16: No point in a building may exceed the maximum exit access travel distance listed in Chapter 10, section 1015, Table 1015.1 of the International Fire Code and international Building Code. 16: Exit hardware and marking shall meet the requirements of the International Fire Code. (IFC Chapter 10) 17: Exits and exit access doors shall be marked by an approved exit sign readily visible from any direction of egress travel. Access to exits shall be marked by readily visible exit signs in cases where the exit or the path of egress travel is not immediately visible to the occupants. Exit sign placement shall be such that no point in an exit access corridor is more than 100 feet (30,480 mm) or the listed viewing distance for the sign, whichever is less, from the nearest visible exit sign. (IFC 1011.1) 18: Every exit sign and directional exit sign shall have plainly legible letters not less than 8 inches (162 mm) high with the principal strokes of the letters not less than 0.76 inch (19.1 mm) wide. The word "EXIT" shall have letters having a width not less than 2 inches (61 mm) wide except the letter "I ", and the minimum spacing between letters shall not be less than 0.378 inch (9.5 mm). Signs larger than the minimum established in section 1011.6.1 of the International Fire Code shall have letter widths, strokes and spacing in proportion to their height. The word "EXIT" shall be in high contrast with the background and shall be clearly discernible when the exit sign illumination means is or is not energized. If an arrow is provided as part of the exit sign, the construction shall be such that the arrow direction cannot be readily changed. (IFC 1011.8.1) 19: Exit signs shall be illuminated at all times. To ensure continued illumination for a duration of not less than 90 minutes in case of primary power loss, the sign illumination means shall be connected to an emergency power system provided from storage batteries, unit equipment or on -site generator. (IFC 1006.1, 1006.2, 1006.3) 20: Aisles in sprinklered buildings shall be a minimum of 44 inches (1118 mm) wide. Aisles shall be a minimum of 96 inches (2438 mm) wide in high -piled storage areas exceeding 2,600 square feet (232 ma) in area, that area accessible to the public and designated to contain high- hazard commodities. Aisles shall be a minimum of 96 inches (2438 nun) wide in areas accessible to the public where mechanical stocking methods are used. (IFC 2306.9.1.1) 21: The required aisle width shall extend from floor to ceiling. Rack structural supports and catwalks are allowed to cross aisles at a minimum height of 6 feet 8 inches (2032 mm) above the finished floor level, provided that such supports do not interfere with fire department hose stream trajectory. (IFC 2306.9.2) 22: All new sprinkler systems and all modifications to existing sprinkler systems shall have fire department review and approval of drawings prior to installation or modification. New sprinkler systems and all modifications to sprinkler systems involving more than 60 heads shall have the written approval of the W.S.R.B., Factory Mutual, Industrial Risk Insurers Kemper or any other representative designated and/or recognized by the City of Tukwila, prior to submittal to the Tukwila Fire Prevention Bureau. No sprinkler work shall commence without approved drawings. (City Ordinance #2050) 23: All sprinler system plans, calculations and the contractors Materials and Test Certificates submitted to the Tukwila Fire Prevention Bureau must be stamped with the appropriate level of competency seal. (WAC 212-80) 24: High -piled combustible storage is combustible materials in closely packed piles more than 12 feet in height or combustible materials on pallets or in racks more than 12 feet in height. Por certain special- hazard commodities such as rubber tires, plastics, some flammable liquids, idle pallets, etc., the critical pile height may be as low as 6 feet. (IFC 2302) 26: Maintain minimum 6" longitudinal flue space between back - to-back racks. (NFPA 13- 12.3.1.14.1) doc: Cond -10/06 D06 -259 Printed: 04- 26.2007 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: httn: / /www.ci.tukwila.wa.us 26: Where storage height exceeds 15 feet and ceiling sprinklers only are installed, fire protection by one of the following methods is required for steel building columns located within racks: (a) one -hour foe proofing, (b) sidewall sprinkler at the 18 foot elevation of the column, (c) ceiling sprinkler density minimums as determined by the Tukwila Fire Prevention Bureau. (NFPA 13) 27: Depending on the classification of the commodity being stored and the size of the storage area, smoke vents, small hose stations and curtain boards may be required by Table 2306.2 of the International Fire Code. Contact the Tukwila Fire Prevention Bureau for further information. 28: Any overlooked hazardous condition and/or violation of the adopted Fire or Building Codes does not imply approval of such condition or violation. 29: These plans were reviewed by Inspector 512. If you have any questions, please call Tukwila Fire Prevention Bureau at (206)575 -4407. doc: Cond - 10/06 * *continued on next page ** 006 -259 Pdnted: 04-26-2007 doe: Cond -10/06 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: htta: / /www.ci.tukwila.wa.us I hereby certify that I have read these conditions and will comply with them as outlined. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provision of any other work or local laws regulating construction or the performance of work. Date: D06 -259 Printed: 04 -26 -2007 CITY OF TUKW!IA DEPT CF CC: . , 0:'i ::LCrtZNT 63W SW i Fii,LN i ER BLVD. TUKWILA, WA 98188 PERMIT CONDITIONS PERMIT CENTER Parcel No.: 3523049085 Permit Number: X06 -259 Address: 1180 ANDOVER PK W TUKW Status: ISSUED Suite No: Applied Date: 07/05/2006 Tenant: SEATTLE CHOCOLATES Issue Date: 07/14/2006 1: ***BUILDING DEPARTMENT CONDITIONS*** 2: No changes shall be made to the approved plans unless approved by the design professional in responsible charge and the Building Official. 3: All permits, inspection records, and approved plans shall be at the job site and available to the inspectors prior to start of any construction. These documents shall be maintained and made available until final inspection approval is granted. 4: All construction shall be done in conformance with the approved plans and the requirements of the International Building Code or International Residential Code, International Mechanical Code, Washington State Energy Code. 5: All rack storage requires a separate permit issued through the City of Tukwila Permit Center. Rack storage over 8 -feet In height shall be anchored or braced to prevent overtuming or displacement during seismic events. The design and calculations for the anchorage or bracing shall be prepared by a registered professional engineer licensed in the State of Washington. 6: There shall be no occupancy of a building until final inspection has been completed and approved by Tukwila building inspector. No exception. 7: Manufacturers installation instructions shall be available on the job site at the time of inspection. 8: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. 9: ** *FIRE DEPARTMENT CONDITIONS*** 10: The attached set of building plans have been reviewed by the Fire Prevention Bureau and are acceptable with the following concerns: 11: The total number of fire extinguishers required for an ordinary hazard occupancy with Class A fire hazards is calculated at one extinguisher for each 1,500 sq. ft. of area. The extinguisher(s) should be of the "All Purpose" (2A, 208:C) dry chemical type. Travel distance to any fire extinguisher must be 75' or less. (IFC 906.3) (NFPA 10, 3 -2.1) 12: Portable fire extinguishers, not housed in cabinets, shall be installed on the hangers or brackets supplied. Hangers or brackets shall be securely anchored to the mounting surface in accordance with the manufacturer's installation instructions. Portable fire extinguishers having a gross weight not exceeding 40 pounds (18 kg) shall be installed so that its top is not more than 5 feet (1524 mm) above the floor. Hand -held portable fire extinguishers having a gross weight exceeding 40 pounds (18 kg) shall be installed so that its top Is not more than 3.5 feet (1067 mm) above the floor. The clearance between the floor and the bottom of the installed hand -held extinguishers shall not be less than 4 inches (102 mm). (IFC 906.7 and IFC 906.9) doc: Conditions D06 -259 Printed: 07 -14 -2006 13: Fire extinguishers shall not be obstructed or obscured from view. In rooms or areas in which visual obstruction cannot be completely avoided, means shall be provided to indicate the locations of the extinguishers. (IFC 906.6) 14: Extinguishers shall be located in conspicuous locations where they will be readily accessible and immediately available for use. These locations shall be along normal paths of travel, unless the fire code official determines that the hazard posed indicates the need for placement away from normal paths of travel. (IFC 906.5) 15: No point in a building may exceed the maximum exit access travel distance listed in Chapter 10, section 1015, Table 1015.1 of the International Fire Code and International Building Code. 16: Exit hardware and marking shall meet the requirements of the International Fire Code. (IFC Chapter 10) 17: Exits and exit access doors shall be marked by an approved exit sign readily visible from any direction of egress travel. Access to exits shall be marked by readily visible exit signs in cases where the exit or the path of egress travel is not immediately visible to the occupants. Exit sign placement shall be such that no point in an exit access corridor is more than 100 feet (30,480 mm) or the listed viewing distance for the sign, whichever is less, from the nearest visible exit sign. (IFC 1011.1) 18: Every exit sign and directional exit sign shall have plainly legible letters not less than 6 inches (152 mm) high with the principal strokes of the letters not less than 0.75 inch (19.1 mm) wide. The word "EXIT" shall have letters having a width not less than 2 inches (51 mm) wide except the letter "I ", and the minimum spacing between letters shall not be less than 0.375 inch (9.5 mm). Signs larger than the minimum established in section 1011.5.1 of the International Fire Code shall have letter widths, strokes and spacing in proportion to their height. The word "EXIT" shall be in high contrast with the background and shall be clearly discernible when the exit sign illumination means is or is not energized. If an arrow is provided as part of the exit sign, the construction shall be such that the arrow direction cannot be readily changed. (IFC 1011.5.1) 19: Exit signs shall be illuminated at all times. To ensure continued illumination for a duration of not less than 90 minutes in case of primary power loss, the sign illumination means shall be connected to an emergency power system provided from storage batteries, unit equipment or on -site generator. (IFC 1006.1, 1006.2, 1006.3) 20: Aisles in sprinklered buildings shall be a minimum of 44 inches (1118 mm) wide. Aisles shall be a minimum of 96 inches (2438 mm) wide in high -piled storage areas exceeding 2,500 square feet (232 m') in area, that area accessible to the public and designated to contain high- hazard commodities. Aisles shall be a minimum of 96 inches (2438 mm) wide in areas accessible to the public where mechanical stocking methods are used. (IFC 2306.9.1.1) 21: The required aisle width shall extend from floor to ceiling. Rack structural supports and catwalks are allowed to cross aisles at a minimum height of 6 feet 8 inches (2032 mm) above the finished floor level, provided that such supports do not interfere with fire department hose stream trajectory. (IFC 2306.9.2) 22: All new sprinkler systems and all modifications to existing sprinkler systems shall have fire department review and approval of drawings prior to installation or modification. New sprinkler systems and all modifications to sprinkler systems involving more than 50 heads shall have the written approval of the W.S.R.B., Factory Mutual, Industrial Risk Insurers Kemper or any other representative designated and /or recognized by the City of Tukwila, prior to submittal to the Tukwila Fire Prevention Bureau. No sprinkler work shall commence without approved drawings. (City Ordinance #2050) 23: All sprinkler system plans, calculations and the contractors Materials and Test Certificates submitted to the Tukwila Fire Prevention Bureau must be stamped with the appropriate level of competency seal. (WAC 212 -80) 24: High -piled combustible storage is combustible materials in closely packed piles more than 12 feet in height or combustible materials on pallets or in racks more than 12 feet in height. For certain special- hazard commodities such as rubber tires, plastics, some flammable liquids, idle pallets, etc., the critical pile height may be as low as 6 feet. (IFC 2302) doc: Conditions D06 -259 Printed: 07 -14 -2006 25: Maintain minimum 6" longitudinal flue space between back -to -back racks. (NFPA 13- 12.3.1.14.1) 26: Where storage height exceeds 15 feet and ceiling sprinklers only are installed, fire protection by one of the following methods is required for steel building columns located within racks: (a) one -hour fire proofing, (b) sidewall sprinkler at the 15 foot elevation of the column, (c) ceiling sprinkler density minimums as determined by the Tukwila Fire Prevention Bureau. (NFPA 13) 27: Depending on the classification of the commodity being stored and the size of the storage area, smoke vents, small hose stations and curtain boards may be required by Table 2306.2 of the International Fire Code. Contact the Tukwila Fire Prevention Bureau for further information. 28: Any overlooked hazardous condition and /or violation of the adopted Fire or Building Codes does not imply approval of such condition or violation. 29 These plans were reviewed by Inspector 512. If you have any questions, please call Tukwila Fire Prevention Bureau at (206)575 -4407. doc: Conditions **continued on next page ** 006 -259 Printed: 07 -14 -2006 I hereby certify that I have read these conditions and will comply with them as outlined. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provision of any other work or local laws regulating construction or the performance of work. Signature: doc: Conditions Print Name: "il �re4s . `mot on Date: Z/ / / 6 D06 -259 Printed: 07 -14 -2006 CITY OF TUKWILA Community Development Department Building Permit No. '7 Public Works Department Permit Center Mechanical Permit No. 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 Plumbing/Gas Permit No. httol/www.ci.tukwila.wa.us Public Works Permit No. I SITE LOCATION Site Address: 11 go ,l / 0ibvc Park w• Tenant Name: 5PR,7P� C.6 60 Property Owners Name: Th ri I- Mailing Address: r SO _ Ma • • i CONTACT PERSON Name: 1 h 5 r- fl ry- Mailing Address: 100 S.W. Cr ' A A.A. ar E -Mail Address: ?Sort' So// &- nw kJ•co,n GENERAL CONTRACTOR INFORMATION - (Contractor Information for Mechanical (pg 4) for Plumbing and Gas Piping (pg 5) ) Company Name: /tor ti Wed 4 ¶ C • Mailing Address: /7 .C. Contact Person: E-Mail v 0! (Z , JU1�1 / E -Mail Address: ✓ Sor art son ' r � w h S . rots.. Contractor Registration Number: /VOr �rh C‘ 9-75" T C ARCHITECT OF RECORD - All plans must be wet stamped by Architect of Record C Name: Mailing Address: Contact Person: E-Mail A. • ess: ENGINEER OF RECORD - All plans must be wet stamped by Engineer of Record //'' Company Name: 262 rk pits C ; r ', Mailing Address: r Contact Person: 6 7 I E -Mail Address. Q:MpplicndonsToni*Apptications On Un0-2006 - Pmmit Appliurion.doc Revised: 4-2006 bh Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. "Please Print • G rAsZtarr City Day Telephone. Fax Number: Ll/I'f State Day Telephone: APC - Pike k' "f Z q 9 City State Zip FaxNumber: it -#- iet State Zip Zip *Wavy Project No. For of ce use on King Co Assessor's Tax No.: 3.-5 - ?Oar 0 Suite Number: Floor( New Tenant: p Yes ❑..No City State Zip Day Telephone:, C' se/ c - 4' Pair Fax Number: y3 C )'4> e 69% Expiration Date: /e /2 7 Ciry p ante Zip Day Telephone: 1 1 0 ? ?8 /C Fax Number: 6 t a c 38/3 Page 1 of 6 BUILDING PERMIT INFORMATION - 206 - 431 -3670 Valuation of Project (contractor's bid price): $ P // 6 J45;,--- Existing Building Valuation: $ Scope of Work (please provide detailed information): jet s/a ((4lYon Cif htt a S' r-ce ' ckt. o, 4 r- Cv4,rrcp o f GLtoco/ tekira e S iA 7 I t / S4re ' Ln /ri rdhoard &� mil i A GviceRr p/lroir . Q4ro S/c.r.., t -44.#4 ,/ l o e rire/4onnf OOM W001 Lt /i.1s, 0or1 AHrG/. rc, )4_o4 P4ase Cdt , r7I '4�l..GCr/s well KS d wr � S And e6�rta aiv. Cr 7 nc/c. ,tnd day ce�ai �s Will there be new rack storage? rYes ❑...No (If yes, a separate permit and plan submittal will be required) Provide All Building Areas in Square Footage Below 4 Number of Parking Stalls Provided: Standard: Will there be a change in use? ❑ ....Yes Q:\ApplicNma'amu- Applicatiaa On LineU-2006 - Permit Application.doc Revised: 4-2006 bh Compact: • PLANNING DIVISION: Single- family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) *For an Accessory dwelling, provide the following: Lot Area (sq ft): Floor area of principal dwelling: Floor area for accessory dwelling: *Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Handicap: If "yes ", explain: FIRE PROTECTION/HAZARDOUS MATERIALS: / 1 / Sprinklers ❑..Automatic Fire Alarm ❑..None ..Other (specify) _ Will there be storage or use of flammable, combustible or hazardous materials in the building? ❑..Yes If "yes", attach list of materials and storage locations on a separate 8 -1/2 x 11 paper indicating quantities and Material Safety Data Sheets. No SEPTIC SYSTEM: ❑ On -site Septic System — For on -site septic system, provide 2 copies of a current septic design approved by King County Health Department. Page 2 of 6 Existing Interior Remodel Addition to Existing Structure New Type of Construction per IBC Type of Occupancy per IBC 1" Floor ST / oee (l� / !000 �! 2n Floor 3 Floor Floors thru Basement Accessory Structure' Attached Garage Detached Garage Attached Carport Detached Carport Covered Deck Uncovered Deck BUILDING PERMIT INFORMATION - 206 - 431 -3670 Valuation of Project (contractor's bid price): $ P // 6 J45;,--- Existing Building Valuation: $ Scope of Work (please provide detailed information): jet s/a ((4lYon Cif htt a S' r-ce ' ckt. o, 4 r- Cv4,rrcp o f GLtoco/ tekira e S iA 7 I t / S4re ' Ln /ri rdhoard &� mil i A GviceRr p/lroir . Q4ro S/c.r.., t -44.#4 ,/ l o e rire/4onnf OOM W001 Lt /i.1s, 0or1 AHrG/. rc, )4_o4 P4ase Cdt , r7I '4�l..GCr/s well KS d wr � S And e6�rta aiv. Cr 7 nc/c. ,tnd day ce�ai �s Will there be new rack storage? rYes ❑...No (If yes, a separate permit and plan submittal will be required) Provide All Building Areas in Square Footage Below 4 Number of Parking Stalls Provided: Standard: Will there be a change in use? ❑ ....Yes Q:\ApplicNma'amu- Applicatiaa On LineU-2006 - Permit Application.doc Revised: 4-2006 bh Compact: • PLANNING DIVISION: Single- family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) *For an Accessory dwelling, provide the following: Lot Area (sq ft): Floor area of principal dwelling: Floor area for accessory dwelling: *Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Handicap: If "yes ", explain: FIRE PROTECTION/HAZARDOUS MATERIALS: / 1 / Sprinklers ❑..Automatic Fire Alarm ❑..None ..Other (specify) _ Will there be storage or use of flammable, combustible or hazardous materials in the building? ❑..Yes If "yes", attach list of materials and storage locations on a separate 8 -1/2 x 11 paper indicating quantities and Material Safety Data Sheets. No SEPTIC SYSTEM: ❑ On -site Septic System — For on -site septic system, provide 2 copies of a current septic design approved by King County Health Department. Page 2 of 6 1 PERMIT APPLICATION NOTES — Applicable to all permits in this application Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. Building and Mechanical Permit The Building Official may grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). Plumbinv Permit The Building Official may grant one extension of time for an additional period not exceeding 180 days. The extension shall be requested in writing and justifiable cause demonstrated. Section 103.4.3 Uniform Plumbing code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OR A Signature: Print Name: e _ ren. oin Mailing Address: Date Application Expires: DI l o s l Date Application Accepted: AGENT: loci SThu. 7t$ s ue_ r0-ItG JU, Q: AppticaaeruWoms- Applications On LineU3006 - Permit Applicntion.doc Revised: 4-2006 M Date: v t 2 7700 Day Telephone ao& a ' - litre 17a drin 1,41 - moss City State Zip Staff Initials: - _ I Page 6 of 6 Parcel No.: Address: Suite No: Applicant: Receipt No.: R07 -01314 Initials: JEM User ID: 1185 Payee: TRANSACTION LIST: Type Method Description doe: Receipt-013 Payment Check 6897 ACCOUNT ITEM LIST: Description PLAN CHECK - NONRES City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us 3523049085 1180 ANDOVER PK W TUKW SEATTLE CHOCOLATES MICHAEL J. SORENSON Account Code 000/345.830 RECEIPT Permit Number: Status: Applied Date: Issue Date: Payment Amount: 858.00 Payment Date: 07/09/2007 12:33 PM Balance: 30.00 Amount 58.00 Current Pmts 58.00 Total: $58.00 D06 -259 ISSUED 07/05/2006 07/14/2006 0101 07/10 9710 TOTAL 58.00 Printed: 07 -09 -2007 Tukwila City of Tukwila 6300 Southcenter BL, Suite 100 / Tukwila, WA 98188 / (206) 431 -3670 Parcel No.: 3523049085 Permit Number: D06 -259 Address: 1180 ANDOVER PK W TUKW Status: APPROVED Suite No: Applied Date: 07/05/2006 Applicant: SEATTLE CHOCOLATES Issue Date: Receipt No.: R06 -01044 Payment Amount: 437.40 Initials: JEM Payment Date: 07/14/2006 01:55 PM User ID: 1165 Balance: $0.00 Payee: MICHAEL J. SORENSON TRANSACTION LIST: Type Method Description Amount Payment Check 6722 437.40 ACCOUNT ITEM LIST: Description Current Pmts BUILDING - NONRES STATE BUILDING SURCHARGE RECEIPT Account Code 000/322.100 432.90 000/386.904 4.50 Total: 437.40 7401 07/14 1716 TOTAL. 437.40 doc: Receipt Printed: 07 -14 -2006 City of Tukwila 6300 Southcenter BL, Suite 100 / Tukwila, WA 98188 / (206) 431 -3670 Parcel No.: 3523049085 Permit Number: D06-259 Address: 1180 ANDOVER PK W TUKW Status: PENDING Suite No: Applied Date: 07/05/2006 Applicant: SEATTLE CHOCOLATES Issue Date' Receipt No.: R06 -00971 Payment Amount: 281.39 Initials: JEM Payment Date: 07/0512006 10:58 AM User ID: 1165 Balance: $437.40 Payee: KURT D FLUEGGE TRANSACTION LIST: Type Method Description Amount ACCOUNT ITEM LIST: Description Current Pmts PLAN CHECK - NONRES RECEIPT Payment Check 6242 281.39 Account Code 000/345.830 281.39 Total: 281.39 7083 07/05 9716 TOTAL 281.39 doc: Receipt Printed: 07-05 -2008 Parcel No.: 3523049085 Address: Suite No: Applicant: SEATTLE CHOCOLATES Receipt No.: R07 -00690 Initials: JEM User ID: 1165 Payee: 1180 ANDOVER PK W TUKW SEATTLE CHOCOLATE COMPANY TRANSACTION LIST: Type Method Description Payment Check 14132 ACCOUNT ITEM LIST: Description BUILDING - NONRES PLAN CHECK - NONRES City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http: //www.ci.tukwila.wa.us Account Code 000/322.100 000/345.830 RECEIPT Permit Number: Status: Applied Date: Issue Date: Payment Amount: Payment Date: Balance: Amount 536.43 Current Pmts 289.96 246.47 Total: $536.43 D06 -259 ISSUED 07 /0S /2006 07/14/2006 1536.43 04/26/2007 04:34 PM 10.00 7580 04/27 9716 TOTAL 536.43 doc: Recelot -06 Printed: 04-26 -2007 NORTHWEST r- e Materla Handling Experts 1100 SW 7th St Renton, WA 98055 FILE COPY - (425) 255 -0500 ph (425) 228 -6946 fax Permit No. RACK INFORMATION SUPPLEMENT SITE ADDRESS: 1180 Andover Park W. TENANT NAME: Seattle Chocolates DATE: June 27, 2006 APPLICANT: Mike Sorenson / (206) 818-4488 REVIEWED FOR CODE COMPLIANCE e nne^vc0 JUL 13 2006 CV 0 I' Of Tukwila 1. Load application and rack configuration drawings attached. RIM ATI��h 11T1iT TnAI 2. Attached plans detail the rack locations, dimensions, and specifications. Attached plans detail the building /ceiling configuration. 3. Stamped engineering calculations attached. 4. Vertical members of storage racks are designed and installed so that failure of one vertical member will not cause collapse of more than the bay or bays directly supported by that member. 5. Commodities stored: Chocolate candy individually wrapped in foil and /or paper in cardboard boxes on wood pallets. Flattened cardboard boxes on wood pallets. Non encapsulated. 6. Sprinkler System Information: .39 GPM / 5600 square feet. 220 sprinklers. System demand: 2550.36 gpm 62.30 psi. Hose allowance: 150 gpm 7. Smoke and heat vents: In place. 8. Building egress and exits indicated on attached drawings. RECEIVED CITY OFTUKWILA JUL 0 5 20nri PERMITCENTER PO(r25't • BY G. OHANIAN DATE 1 - 07 SUBJECT RAdK DEp 4N & ENdINEERINt d0. 412 ir pat BROADWAY, OUTTE #204 GALE, DA. 91204 TEL:(818)240 -3810 FAX:(818)240 -3813 STRUCTURAL CALCULATIONS OF STORAGE RACKS FOR: SEATTLE CHOCOLATE CO. 1180 ANDOVER PARK WEST TUKWILA, WA. 98188 PER IBC 2003 EDITION STORAGE RACKS CAPACITY: AS SHOWN ON ELEVATIONS CALCS. 1 THRU 6 DRAWINGS: RD -11729 C� T ILA JAN 2 3 2007 PERMITCENTER SHEET NO 1 RD - 11729 JOB NO. FILE COPY Perris t No. M_n �ru e _ C. ( EXPIRES 12- 26 -07 REVISION NC1 PUP 291 BY, G. GHANIAN DATE 1 -12 -07 SUBJECT 1 3500 #/ LEVEL TYPE "A" 96 1 2000 #/ LEVEL TYPE "C" TYPE "E" RAdK DEOIdN Sc ENG41NEERINd do. 412 WEBT BROADWAY, OU1TE #204 LENDALE, CIA. 91204 TEL:(818)240 -3810 FAX:(818)240 -3813 i0 4' 0 4' n 4' SIDE VIEW 96" 3500 #/ LEVEL TYPE "8" & "F" 46" r 2000 #/ LEVEL I 2000 #/ LEVEL 1000 #/ LEVEL TYPE "D" .BEAM 1.111d SIDE VIEW I =1.84 Fy =50 KSi. SHEET NO 2 JOB NO. RD -11729 SIDE VIEW 3500 11/ LEVEL +25X. IMPACT LOAD 1900 jt/ BEAM M _ 96 "x1.9 = 23 "K 8 S 0 "K = .76<.85 5xWXe " 384x1xxE -.38< 80 = •53" BY G. OHANIAN DATE. 1 - 12 - 07 SUBJECT SFISMIC DESIGN V S R 4 x W IBC 2003, SEC. 2208 STRESS 1 =1 R =6 DOWN AISLE (MOM. CONN.) R =4 CROSS AISLE (BRACED) S05 =.85 W= D.L. +3L.L. LOAD PER COLUMN TYPES "A ", "B" & "F" L.L.= 3 3 3x , K =3.5 K W =.1 3.5 3.6 K ✓ — .85x1x3.6 = 36 K wKra*. 6x1.4 ✓ — .85x1x3.6 = . 54 K TRIMS. 4x1.4 TYPE "C" L.L. =2x 3x2 K =2 K 3 2 coL W =.1 D.L 2LL 2.1 K V — .85x1x2.1 = 2 1K LDKDR. 6x1.4 ✓ — .85x1x2.1 = 3 2 TRANS. 4x1.4 • TYPE "D" L.L „I (x1K) +(2x2K) =23 W =.1 2.3 2.4 K V = .85xtx2.4 = 24 K ...T. 6x 1.4 • ✓ — .85x1x2.4 = MANOR. 4x1.4 M — ,24Kx20" —2'x COL 2 RACK DEOIdN & ENc#INEERINcI CO. 412 WE BROADWAY, OUTTE #204 LENDALE, OA. 91204 TEL:(818)240 -3810 FA1:(818)240 -3813 S 5 =1.27 (USGS MAP) Sus =1.27 (EQ. 16 -38) S us =1—x1.27 =.85 (EQ. 16 -40) LONGIT SEISMIC TYPE "E" . 36K .21 K W= .1 D.E + 2 LL 2.1 K M .21 Kx30" =6"K L.L.= 2 x .(2x1K) +(2x2K) • 3 2 coL. 3 2 coL V = .85xtx2 1 = .21 K umom 6x1.4 — K 13'K 0 SHEET NO 3 JOB N0. RD -1t729 By G. OHANIAN DATE 1 -12 -07 SUBJECT COLUMN ANALYSIS COLUMN AT "A ", "B" r M COMBINED STRESS RATIO a aM + M 4f + 2 = .87<1.33 BASE PLATE ANCH. TENSION - 13-(3.6x3") = 36 x ANCHOR SHEAR = t = 18 K (2) -1/2 "N HILTI KWIK BOLT 3 ANCHORS ESR -1385 OR APPROVED EQUAL. DESIGNED FOR 1/2 STRESS. (NO SPECIAL INSPECTION REQ'D) COLUMN AT "C ". "D" & "r TYPE "E" 1 We" t - .09` BASE PLATE ANCH. TENSION = 0 ANCHOR SHEAR = .21 K Fy =50 Ks' A =.53 S, =.45 r =1.1 r y = COMBINED STRESS RATIO cM0 %IT = .90<1.33 RAdK DEOIdN & ENcINEERINd d0. 412 BROADWAY, MATE 1,204 LENDALE, CIA. 91204 TEL:(818)240 -3810 FAX4818)240 -3813 Fy =50 KsI A =.78 S =.80 r =1.2 r y 1. 1 1., TYPES "C & "D" 1 5/8 " , x- (1)-1/2"0 HILTI KWIK BOLT 3 ANCHOR ESR -1385 OR APPROVED EQUAL. DESIGNED FOR 1/2 STRESS. (NO SPECIAL INSPECTION REQ'D) .KI_ 73x1.7_103 rx 1.2 T _TT = 47 Y M =S •Fb =24 "K Fy =50 KSi A =.54 S =.42 r =1.2 r = . 64 Fe= 2 -27 ( 31 ) Fn - Fy (1 4Fe )= 26 Ksi P F xA 21 K Pa Pn 11 = 1.92 — .K1 48 = 74 rx _M =68 Y M = S . Fb =13 `K 2.1 K SHEET NO 4 JOB NO. RD -11729 7 3/4 "x5 "x3/8" BASE PLATE Fe =( K j 2 - 52 f Fn =Fy (1 4F, )= 38 Ksi P =F xA= 20 K Pa 10 a 1.92 3 "x3 "x1 /8" BASE PLATE By, G. GHANIAN DATE 1 -12 -07 SUBJECT MOMENT AT BEAM CONNECTION TYPES "A ", "B ", "E" & "F" 7/16 "0 RIVET A = .1 Fy =79 Va = .1 x79x.4 = 3 K Ma =3Kx4 "x1.33 = 16 " 2 PIN CONN. CONN. MOMENT AT BEAM CONNECTION TYPES "C" & "D" 1/2 "0 ROD Va =2.8 K Ma= 2.8 x4.5"x1.33 = 16 2 PIN CONNECTOR OVERTURNING M .54 "x.5x1.15 =119 MR = 3.6 K x44" = 158 NO UPLIFT LOAD TO DIAGONAL P= .54 =.57 44 Fy =50 K51 A =.31 r =.48 Q =.74 L= 58" F = 36 Ksi F =14 A =.20 Fa= 10.6 P = 3.3 K CHECK WELDS 1/8" WELD 1.5" LONG EACH SIDE (3" TOTAL) 3x.125x.707x70x.3 = 5.7 K RAdK DESIUN & EN(tINEERINd do. 412 WEI1' BROADWAY,JITE #204 dLENDALE, dA. 91204 TEL (818)240 -3810 FAB:(818)240 -3813 TOP LEVEL LOADING M •18Kx2x192 "= 69 'K Mq 1.3Kx44 " =57 "K UPLIFT = 69 - 57 — 48 K 42" SEC. B —B SHEET NO 5 JOB NO RD 11729 By G. OHANIAN DATE 1 -12 -07 SUBJECT LOAD TO DIAGONAL Kx2 4 _ .88 K F=36 KSI A =.45 P .45x36x.6x1.33 =13 88 K CHECK WELDS CHECK SLAB 3600 36 1000 3.6x144=518 5 8 =23" M= (12 ) 2 x12 = 1042 "# S= 12x6 = 72 6 1042 = 14 <1.6 2000 =72 72 1/8" WELD 2" LONG EACH SIDE (4" TOTAL) 4x.125x.707x70x.3 = 7.4 K RAdK DEOION & EN(#INEERINd do. 412 WE BROADWAY, QUITE #204 LENDALE, dA. 91204 TEL:(818)240 -2810 FAX:(818)240 -3813 11/ t =.07" 3600 6" CONCRETE SLAB 2000 PSI. CONC. 1000 PSF. SOIL SHEET NO 6 JOB N0. RD -11729 BY G. OHANIAN DATE. 6 - 27 - 06 SUBJECT RAdK DESIdN & ENdINEERINd d0. 412 TEST BROADWAY, SUITE #204 (GGLENDALE, CA. 91204 TE14818)240 -3810 7114818)240 -3813 STRUCTURAL CALCULATIONS OF STORAGE RACKS FOR: / C O D 0 x^ OM p�N A ti SEATTLE CHOCOLATE CO. / t' 7trt0 , TUKWILA, WA. 98188 p Gjh/ wd /5! !N PER IBC 2003 EDITION STORAGE RACKS CAPACITY: 1180 ANDOVER PARK WEST 3500 # / LEVEL CALCS. 1 THRU 4 DRAWINGS: RD -11064 EXPIRES 12 -26 -07 FILE copy Permit No. SHEET 140. 1 JOB 140. RD - 11064 RECEIVED CITY 0FTUKWILA JUL 0 5 2006 PBIMITCENTER By G. OHANIAN DATE. 6 -27 -06 SUBJECT BEAM M= 96 "x1.9, =23•K 8 S •K = .76<.85 A= 5xWxL 384x1, xE .38 "< 180 W =D.L.+ 2 L.L TYPE "A" LOAD PER COLUMN L.L. = 2 x 3x . K - 3.5 K W =.1 3.5 3.6 K V _ .85x1 x3.6 _ LOWE 6x1.4 V _ .85xix3.6 = 5 ,0 um?. 4x1.4 RACK DESIGN & ENdINEERINO do. 412 WEST BROADYSY, OUTTE #204 LENDALE, the 91204 TEL:(810240 -3810 BA%018)240 -3813 TYPE "B" 3500 #/ LEVEL+25% IMPACT LOAD 1900 #/ BEAM I, =1.84 S, =.85 Fy= 50 x51. SEISMIC DESIGN V= RX� .4 W IBC 2003. SEC. 2208 S =1.27 (USGS MAP) I =1 ST RE S S D S =1.27 (EQ. 16 -38) R =6 DOWN AISLE (MOM. CONN.) S DS = 3x =.85 (E0. 16 -40) R =4 CROSS AISLE (BRACED) S =.85 LONGIT SEISMIQ .36 K 13'K SIDE VIEW SHEET NO 2 JOB NO RD -11064 BY G. OHANIAN DATE 6 -27 -06 SUBJECT — COLUMN ANALYSIS 1, x- 3" t JJ COMBINED STRESS RATIO pp- x+11 = . 87<1.33 RACK DESIdN & ENdINEERINd CO. 412 WET BROADWAY, PITE #204 LENDALE, CIA. 91204 TEL:(818)240 -3810 FA%:(818)240 -8813 Fy =50 KSI A =.78 S =.80 r =1.2 r =1.1 BASE PLATE ANCH. TENSION = 13—(3.6x3") _ 36 K ANCHOR SHEAR = _ _ 18 K (2) -1/2 "0 HILTI KWIK BOLT 3 ANCHORS ESR -1385 OR APPROVED EQUAL. DESIGNED FOR 1/2 STRESS. (NO SPECIAL INSPECTION RED MOMENT AT BEAM CONNECTION 7/16 "0 RIVET A =.1 Fy =79 KSI Va = .1 x79x.4 3 Ma = 3Kx4 "x1.33 = 16 .K 2 PIN CONN. CONN. = —103 y =B.= 47 M =S 4=24 K 11.5 • Fe = — 27 ( r F„ =Fy(1— 4 ) =26 P„ =F 21 K p a = 19 11 K 36 K 13 " / SHEET 140 3 JOB NO. RD -11064 7 3/4 "x5 "x3/8" BASE PLATE BY G. OHANIAN DATE 6 - 27 - 06 SUBJECT - OVERTURNING = .54 "x.5x1.15 =119'K M MR = 3.6 K x44" = 158 "K NO UPLIFT LOAD TO DIAGONAL P= .54 . =.57 44 Fy =50 KSI A =.31 r =.48 Q =.74 L= 58" CHECK SLAB 3600 3.6 °' 1000 =23" Fa= 10.6 P = 3.3 K CHECK WELDS 1/8" WELD 1.5" LONG EACH SIDE (3" TOTAL) 3x.125x.707x70x.3 = 5.7 K 3.6x144=518 0 " M= (1 )x1000x 2 x12 =1042 "4 S _ 12x6 = 72 6 1042 — 14 <1.6 V2000 =72 72 RAdK DEOI(#N & EN(INEERINd do. 412 WE BROADWAY, OUFTE #204 4LENDALE, dA. 91204 TEL:(818)240 -3810 FAS:(818)240 -3813 UPLIFT= 6 =.28 K TOP LEVEL 1 OADING M .18Kx2x192 "= 69 ' K MR =1.3 Kx44 "= 57 .K 3600 / sFC. R —H 11.5' 6' CONCRETE SLAB 2000 PSI. CONC. 1000 PSF. SOIL SHEET NO 4 JOB NO. RD -11064 06-04 -2007 MIKE SORENSON 1100SW7ST RENTON WA 98055 RE: Permit No. D06 -259 1180 ANDOVER PK W TUKW Dear Permit Holder: In reviewing our current records the above noted permit has not received a final inspection by the City of Tukwila Building Division. Per the International Building Code and/or the International Mechanical Code, every permit issued by the Building Division under the provisions of this code shall expire by limitation and become null and void if the building or work authorized by such permit is not commenced within 180 days from the date of such permit, or if the building or work authorized by such permit is suspended or abandoned at any time after the work is commenced for a period of 180 days. Based on the above, you are hereby advised to: Call the City of Tukwila Inspection Request Line at 206 - 431 -2451 to schedule for the next or final inspection. This inspection is intended to determine if substantial work has been accomplished since issuance of the permit or Last inspection; or if the project should be considered abandoned. If such determination is made, the Building Code does allow the Building Official to approve one or more extensions of time for additional periods not exceeding 90 days each. Extension requests past be in writinr and provide satisfactory reasons why circumstances beyond the applicants control have prevented action from being taken. In the event you do not call for the above inspection and receive an extension prior to 07/10/2007 , your permit will become null and void and any further work on the project will require a new permit and associated fees. Thank you for your cooperation in this matter. Sincerely, fer Marshall, Pennit Technician xc: Permit File No. D06-259 Steven M. Mullet, Mayor Department of Community Development Steve Lancaster, Director 6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone: 206- 431 -3670 • Fax: 206-431-3665 12 -06 -2006 MIKE SORENSON 1100SW7ST RENTON WA 98055 RE: Permit No. D06 -259 1180 ANDOVER PK W TUKW Dear Permit Holder: City of Tukwila Steven M Mullet, Mayor Department of Community Development Steve Lancaster, Director • In reviewing our current records the above noted permit has not received a final inspection by the City of Tukwila Building Division. Per the International Building Code and/or the International Mechanical Code, every permit issued by the Building Division under the provisions of this code shall expire by limitation and become null and void if the building or work authorized by such permit is not commenced within I80 days from the date of such permit, or if the building or work authorized by such permit is suspended or abandoned at any time after the work is commenced for a period of 180 days. Based on the above, you are hereby advised to: Call the City of Tukwila Inspection Request Line at 206 -431 -2451 to schedule for the next or final inspection. This inspection is intended to determine if substantial work has been accomplished since issuance of the permit or last inspection; or if the project should be considered abandoned. If such determination is made, the Building Code does allow the Building Official to approve one or more extensions of time for additional periods not exceeding 90 days each. Extension requests must be in writing. and provide satisfactory reasons why circumstances beyond the applicants control have prevented action from being taken. In the event you do not call for the above inspection and receive an extension prior to 01/10/2007 , your permit will become null and void and any further work on the project will require a new permit and associated fees. Thank you for your cooperation in this matter. Sincerely, rshall, Permit Teetmician At4itvi xc: Permit File No. D06 -259 6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone: 206 -431 -3670 • Fax: 206 -431 -3665 January 12, 2007 Mike Sorenson Northwest Handling Systems, Inc. 1100 SW 7 St Renton WA 98057 RE: Request for Extension Development Permit No. D06 -259 Seattle Chocolates —1180 Andover Pk W Dear Sorenson: This letter is in response to your written request for an extension to Permit No. D06 -259. The Building Official has reviewed your letter and considered your request to extend the above referenced permit. The City of Tukwila Building Division will be extending the expiration date of your permit for an additional 180 days (through July 10, 2007). If you should have any questions, please contact our office at (206) 431 -3670. Sincerely, Je fifer T Akov444 arshall clinician File: Permit No. D06 -259 City of Tukwila Steven M. Mullet, Mayor Department of Community Development Steve Lancaster, Director P:Vennifet'P.xtension 1<tten\PemiimVN16 -259 Permit Extension.doc jem Page 1 of 1 6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone: 206- 431 -3670 • Fax: 206- 431 -3665 4252286946 NW HANDLING SYS 1100 S. W, 7'" St Renton, WA 98057 Phone: 425-255-0500 xtn. 112 Fax: 425 -228 -6946 800 - 426 -3888 Msoronsonanwhs.com www.nwhtcom Jennifer Marshall City of Tukwila Bldg. Dept. To: Co: CC: Fax; 206- 431 -3665 Re: 006 -259 / Seattle Chocolates Hi Jennifer- Hope all is well with you. This rack project is still alive and kicking. They have changed warehouse managers and have modified the layout. I plan to submit the revised layout plans to The City next week. t hope to have the revision in by the deadline but might not make it. Will this request suffice for an extension on this permit? Thanks. RECEIVED 01-05-'07 09:01 FROM- 4252286946 Fax Cover 292 P01 JAN 05 '07 09:08 TY 11A JAN O5204- PEFaiinara From: Mike Sorenson Co: NW Handling Systems Fax: (425)228 -6946 Date: 1/5/2007 Total Pages: 2 eitiaefrai Giet /8o der 01-67-0 610 ot. to • o1- Grr 17 • ID, i TO- c P001/002 ` ;- ► ; ; ;;I Q COORD COPY PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER: D06 -259 DATE: 07 -3 -07 PROJECT NAME: SEATTLE CHOCOLATES SITE ADDRESS: 1180 ANDOVER PK W Original Plan Submittal Response to Incomplete Letter #_ Response to Correction Letter #, X Revision # 2 After Permit Issued DEPARTMENTS: di ng D ivis si i o n Public Works ❑ DETERMINATION COMPLETENESS: (Tues., Thurs.) DUE DATE: 07 -5 -07 Complete TUESITHURS ROIUTING: Please Route Documents/routing slip.doc 2 -28-02 NI 011 Fire Prevention Structural ❑ Permit Coordinator Incomplete Structural Review Required Planning Division Not Applicable Comments: X Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: ❑ No further Review Required REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: DUE DATE: 08 -2 -07 Approved ❑ Approved with Conditions d Not Approved (attach comments) ❑ Notation: REVIEWER'S INITIALS: DATE: Penult Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: ACTIVITY NUMBER: D06 -259 DATE: 01 -23 -07 PROJECT NAME: SEATTLE CHOCOLATES SITE ADDRESS: 1180 ANDOVER PK W Original Plan Submittal Response to Correction Letter # Response to Incomplete Letter # X Revision # 1 After Permit Issued DEPARTMENTS: Bu d'g Public Works DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete Comments: Approved Notation: Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: TUES/THURS ROUTING: Please Route Structural Review Required ❑ No further Review Required DATE: Documents/routing sl ip.doc 2.28 -02 PERMIT COORD COPY PLAN REVIEW /ROUTING SLIP REVIEWER'S INITIALS: APPROVALS OR CORRECTIONS: REVIEWER'S INITIALS: 6I( kit 14 Fire Prevention Structural Incomplete ❑ Approved with Conditions❑ DATE: Planning Division ❑ Permit Coordinator ❑ DUE DATE: 01 -25-07 Not Applicable ❑ DUE DATE: 02-22-07 Not Approved (attach comments) ❑ Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: ACTIVITY NUMBER: D06 -259 DATE: 07 -05 -06 PROJECT NAME: SEATTLE CHOCOLATES SITE ADDRESS: 1180 ANDOVER PK W X Original Plan Submittal Response to Incomplete Letter # Response to Correction Letter # Revision # After Permit Issued DEPARTMENTS: it UG 1 Bu 'tng Division Public Works ❑ DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete Comments: APPROVALS OR CORRECTIONS: Approved ❑ Notation: REVIEWER'S INITIALS: Documentsfrouting slip.doc 2-28-02 PERMIT COORD COPY PLAN REVIEW /ROUTING SLIP 612 14W( Fire Prevention Structural Incomplete ❑ Planning Division ❑ Permit Coordinator ❑ DUE DATE: 07-06-06 Not Applicable ❑ Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: TUES/THURS ROUT)NG: Please Route 12 Structural Review Required REVIEWER'S INITIALS: Approved with Conditions No further Review Required DATE: DATE: DUE DATE: 08-03-06 Not Approved (attach comments) E Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: REVISION NO. DATE RECEIVED STAFF INITIALS ISSUED DATE STAFF INITIALS STAFF INITIALS STAFF INITIALS 2 D ) Summary of Revision: Received by: Received by: REVISION NO. DATE RECEIVED STAFF INITIALS ISSUED DATE STAFF INITIALS STAFF INITIALS STAFF INITIALS 2 D ) Summary of Revision: Received by: REVISION NO. DATE RECEIVED STAFF INITIALS ISSUED DATE STAFF INITIALS STAFF INITIALS STAFF INITIALS 2 D ) Summary of Revision: Received by: REVISION NO. DATE RECEIVED STAFF INITIALS ISSUED DATE STAFF INITIALS STAFF INITIALS 2 D ) 01 ��,,, Summary of Revision: 1 Nfd ,4e-i. 2 Summary of Revision: V Received by: ,flay al t 0 ,, q S on Received by:/t1 Ike . t'evtXon REVISION NO. DATE RECEIVED STAFF INITIALS STAFF INITIALS ISSUED DATE STAFF INITIALS I Ot -it \J tVv. Received by: Summary of Revision: 1 Nfd ,4e-i. 2 cyl/o PE P: = WOW,. Received by: ,flay al t 0 ,, q S on REVISION NO. DATE RECEIVED STAFF INITIALS ISSUED DATE STAFF INITIALS Summary of Revision: Received by: PROJECT NAME: Lk1 l ('kb pt„Al % PERMIT NO: e- 2c SITE ADDRESS: I I $O 'now ORIGINAL ISSUE DATE: al- - (4t . G1 REVISION LOG (please print) (please print) (please print) (please print) (please print) » City of Tukwila Revision submittals must be submitted in person at the Permit Center. Revisions will not be accepted through the mail, fax, eta Date: 1/2/0 7 Plan ChecWPermlt Number: 1 O 6 - r'' ❑ Response to Incomplete Letter # _ ❑ Response to Correction Letter # a Revision # ER- after Permit is Issued ❑ Revision requested by a City Building Inspector or Plans Examiner Project Name: cia- e- aocO to f.2. 5 Project Address: 1(gD .f- nJ,vcr ark il/'• Contact Person: Mike- $'rol SOn Phone Number:,206 - Sl8 ewes- Summary of Revision: ine r 1TaS t n Pack G� llo.O f On / citccniyf 5 rn r'ar cc Sp4- ;(e'rcr lft ? 4rnsr'q» /e-ny no Nn // r \ art-,; (rod CA :red Cred ,n rot rlrs. ✓ Sheet Number(s): "Cloud" or highlight all areas of revision including date of • revision Received at the City of Tukwila Permit Center by: QD Entered in Permits Plus on 7 —,)---01 lappbcabonsVonns- applications on Ime4evisron submittal Created: 8 -13 -2004 Revised: Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Fax: 206 -431 -3665 Web site: http: / /www.cr.rukwrla.wa.us Steven M Mullet, Mayor Steve Lancaster, Director HECEIVEU 1Of T UKWItA 2007 PERMIT CENTER Revision submittals must be submitted in person at the Permit Center. Revisions will not be accepted through the mail, fax, etc. Date: 1 /3 3 1 T Plan Cbeck/Permit Number: 1)0 6 a5 ❑ Response to Incomplete Letter 11 ❑ Response to Correction Letter # Revision # / after Permit is Issued ❑ Revision requested by a City Building Inspector or Plans Examiner 5 -atett-24- co toic _S Project Name: Project Address: jl (6 Arzeover P* it/. Contact Person: Pti/cc Jprexsc.: Phone Number: X6-ere- VtlP's Summary of Revision: / ..-Gaa445nr eiCC.t`ated A 2 9 2 4 70 t e V than u r ' t — or� /44( rttCre/.cv, ® /e; S1 wi re./ /ay7SS T . Cvisn'�clC ier'inann a 4 ate, J VMMknDkui c,► &( 't , ttc 1- Cv t1200 2 ov cram) Sheet Number(s): "Cloud" or highlight all areas of revision including date of revision Received at the City of Tukwila Permit Center by Entered in Permits Plus on 41 14 o Vppl wdaonsVomu- pplicauonsonhna cvjrionsubmmal Created: 8-13-2004 Revised irs City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Fax: 206431 -3665 Web site: http: //www.cl.takwtla.waus Ai Steven M Mullet, Mayor Steve Lancaster, Director RECEIVE 232007 PERMIT CENTEr License Information License NORTHWH275JF Licensee Name NORTH WEST HANDLING SYS MC Licensee Type CONSTRUCTION CONTRACTOR UBI 600051641 Ind. Ins. Account Id 32999900 Business Type CORPORATION Address 1 1100 SW 7TH ST Address 2 City RENTON County KING State WA Zip 980552939 Phone 4252550500 Status ACTIVE Specialty 1 GENERAL Specialty 2 UNUSED Effective Date 4/6/1973 Expiration Date 10/9/2007 Suspend Date Separation Date Parent Company Previous License Next License NORTHHS963ND Associated License Bond Information Bond Bond Company Name Bond Account Number Effective Date Expiration Date Cancel Date Impaired Date Bond Amount Received Date #6 TRAVS 81S103354822BCM 10/01/2001 Until Cancelled 01/01/1980 $12,000.00 10/09/2001 Business Owner Information Name Role Effective Date Expiration Date FRANCK, JAMES J 01/01/1980 THOMAS, KEVIN A 01/01/1980 KOSTY, CLARK R 01/01/1980 Look Up a Contractor, Electric : an or Plumber License Detail % Washington State Department of Labor and Industries General/Specialty Contractor A business registered as a construction contractor with L &I to perform construction work within the scope of its specialty. A General or Specialty construction Contractor must maintain a surety bond or assignment of account and carry general liability insurance. Page 1 of 3 https: // fort ress. wa. gov /Ini/bbip/ printer .aspx?License= NORTHWH275JF 07/14/2006 x x x x x