Loading...
HomeMy WebLinkAboutPermit D06-297 - Accu-Tech Corporation - Storage RacksACCU -TECH CORPORATION 1109 ANDOVER PK W D06 -297 Parcel No.: 3523049110 Address: 1109 ANDOVER PK W TUKW Suite No: Tenant: Name: ACCU -TECH CORPORATION Address: 1109 ANDOVER PR W , TUKWILA WA City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206- 431 -3670 Fax: 206 -431 -3665 Web site: httn :: //www.ci.tukwila.wa.us Owner: Name: TWO NINE THREE & FOUR LTD Address: 1325 4TH AVE SUITE 1940 , SEATTLE WA 98101 Phone: Contact Person: Name: MIKE SORENSON Address: 1 100 SW 7 ST , RENTON WA 98057 Phone: 208 -818 -4488 Contractor: Name: NORTH WEST HANDLING SYSTEMS INC Address: 1100 S.W. 7T1i STEEP , RENTON, WA 98058 Phone: 208 288 -0500 Contractor License No: NORTHWH275JF doc: IBC -10/06 DEVELOPMENT PERMIT * *continued on next page ** Permit Number: D06 -297 Issue Date: 08/24/2006 Permit Expires On: 07/16/2007 Expiration Date: 10/09/2007 Steven M. Mullet, Mayor Steve Lancaster Director DESCRIPTION OF WORK: INSTALLATION OF PALLET RACKING FOR STORAGE OF WIRING AND CABLING MATERIALS FOR COMMUNICATIONS AND PHYSICAL SECURITY. Value of Construction: $0.00 Fees Collected: $969.98 Type of Fire Protection: SPRINKLERS International Building Code Edition: 2003 Type of Construction: RACKS Occupancy per IBC: 0011 D06 -297 Printed: 01 -23 -2007 Public Works Activities: Channelization / Striping: N Curb Cut / Access / Sidewalk / CSS: N Permit Center Authorized Signature; I hereby certify that I have read an governing this work will be compile City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us Permit Number: DO6 -297 Issue Date: 08/24/2006 Permit Expires On: 07 /16/2007 Fire Loop Hydrant: N Number: 0 Size (Inches): 0 Flood Control Zone: N Hauling: N Start Time: End Time: Land Altering: N Volumes: Cut 0 c.y. Fill 0 c.y. Landscape Irrigation: N Moving Oversize Load: N Start Time: End Time: Sanitary Side Sewer: N Sewer Main Extension: N Private: Public: Storm Drainage: N Street Use: N Profit: N Non - Profit: N Water Main Extension: N Private: Public: Water Meter: N IQ Date: el t 1 Steven M. Mullet, Mayor Steve Lancaster, Director s permit and know the same to be true and correct. All provisions of law and ordinances er specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance - • ork. I am authorized to sign and obtain this development permit. Signature: Date: /7.) 3 ,/0 7 Print Name: This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. doc: IBC -10/06 D06 -297 Printed: 01 -23 -2007 City aifTukwila Parcel No.: 3523049110 Address: 1109 ANDOVER PK W TUKW Suite No: Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: ci.tukwila.wa.us Tenant: Name: ACCU -TECH CORPORATION Address: 1109 ANDOVER PK W, TUKWILA WA DEVELOPMENT PERMIT Owner: Name: TWO NINE THREE & FOUR LTD Address' 1325 4TH AVE SUITE 1940, SEATTLE WA, 98101 Phone: Contact Person: Name: MIKE SORENSON Address: 1100 SW 7 ST, RENTON WA, 98057 Phone: 206 - 818 -4488 Contractor: Name: NORTH WEST HANDLING SYSTEMS INC Address: 1100 S.W. 7TH STEET, RENTON, WA 98055 Phone: 206 255 -0500 Contractor License No: NORTHWH275JF Value of Construction: $0.00 Type of Fire Protection: SPRINKLERS Type of Construction: RACKS doc: IBC - PERMIT **continued on next page** Permit Number: DO6 -297 Issue Date: 08/24/2006 Permit Expires On: 02/20/2007 Expiration Date:10 /09/2007 Steven M. Mullet, Mayor Steve Lancaster, Director DESCRIPTION OF WORK: INSTALLATION OF PALLET RACKING FOR STORAGE OF WIRING AND CABLING MATERIALS FOR COMMUNICATIONS AND PHYSICAL SECURITY. Fees Collected: $969.98 International Building Code Edition: 2003 Occupancy per IBC: 0011 DO6 -297 Printed: 08-24-2006 Public Works Activities: Channelization / Striping: N Curb Cut / Access / Sidewalk / CSS: N City &?Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Fax: 206 -431 -3665 Web site: ci.tukwila.wa.us Fire Loop Hydrant: N Number: 0 Size (Inches): 0 Flood Control Zone: N Hauling: N Start Time: End Time: Land Altering: N Volumes: Cut 0 c.y. Fill 0 c.y. Landscape Irrigation: N Moving Oversize Load: N Start Time: End Time: Sanitary Side Sewer: N Sewer Main Extension: N Private: Public: Storm Drainage: N Street Use: N Profit: N Non- Profit: N Water Main Extension: N Private: Public: Water Meter: N Permit Center Authorized Signature: I hereby certify that I have read and ordinances governing this work will b Print Name: doc: IBC - PERMIT Permit Number: D06 -297 Issue Date: 08/24/2006 Permit Expires On: 02/20/2007 Date: Steven M. Mullet, Mayor Steve Lancaster, Director permit and know the same to be true and correct. All provisions of law and ith, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this development permit. Signature: Date: 2 ! 2 'yea 6 This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. D06 -297 Printed: 08 -24 -2006 Parcel No.: 3523049110 Address: Suite No: Tenant: City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us 1109 ANDOVER PK W TUKW ACCU -TECH CORPORATION 1: ** *BUILDING DEPARTMENT CONDITIONS * ** 8: ** *FIRE DEPARTMENT CONDITIONS * ** PERMIT CONDITIONS Permit Number: Status: Applied Date: Issue Date: D06 -297 ISSUED 08/01/2006 08/24/2006 2: No changes shall be made to the approved plans unless approved by the design professional in responsible charge and the Building Official. 3: All permits, inspection records, and approved plans shall be at the job site and available to the inspectors prior to start of any construction. These documents shall be maintained and made available until final inspection approval is granted. 4: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. 6: The attached set of building plans have been reviewed by the Fire Prevention Bureau and are acceptable with the following concerns: 7: The total number of fire extinguishers required for an ordinary hazard occupancy with Class A fire hazards is calculated at one extinguisher for each 1.600 sq. ft. of area. The extinguisher(s) should be of the "All Purpose" (2A, 20B:C) dry chemical type. Travel distance to any fire extinguisher must be 78' or less. (IFC 906.3) (NFPA 10, 3- 2.1)(warehouse area) 8: The total number of fire extinguishers required for a light hazard occupancy with Class A fire hazards is calculated at one extinguisher for each 3,000 sq. ft. of area. The extinguisher(s) should be of the "all purpose" (2A, 10 B:C) dry chemical type. The travel distance to any extinguisher must be 78' or less. (IFC 906.3) (NFPA 10, 3- 2.1)(office area.) 9: Fire extinguishers shall not be obstructed or obscured from view. In rooms or areas in which visual obstruction cannot be completely avoided, means shall be provided to indicate the locations of the extinguishers. (IFC 906.6) 10: Extinguishers shall be located in conspicuous locations where they will be readily accessible and immediately available for use. These locations shall be along normal paths of travel, unless the fire code official determines that the hazard posed indicates the need for placement away from normal paths of travel. (IFC 906.8) 11: Fire extinguishers require monthly and yearly inspections. They must have a tag or label securely attached that indicates the month and year that the inspection was performed and shall identify the company or person performing the service. Every six years stored pressure extinguishers shall be emptied and subjected to the applicable recharge procedures. If the required monthly and yearly inspections of the fire extinguisher(s) are not accomplished or the inspection tag is not completed, a reputable fire extinguisher service company will be required to conduct these required surveys. (NFPA 10, 4-3, 4-4) 12: Egress doors shall be readily openable from the egress side without the use of a key or special knowledge or effort. doc: Cond - 10/06 008 -297 Printed: 01 -23 -2007 (IFC 1008.1.8.3 subsection 2.2) City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us 13: Dead bolts are not allowed on auxiliary exit doors unless the dead bolt is automatically retracted when the door handle is engaged from inside the tenant space. (IFC Chapter 10) 14: Door handles, pulls, latches, locks and other operating devices on doors required to be accessible by Chapter 11 of the International Building Code shall not require tight grasping, tight pinching or twisting of the wrist to operate. (IFC 1008.1.8.1) 15: Exit hardware and marking shall meet the requirements of the International Fire Code. (IFC Chapter 10) 16: Where storage height exceeds 18 feet and ceiling sprinklers only are installed, fire protection by one of the following methods is required for steel building columns located within racks: (a) one -hour fire proofing, (b) sidewall sprinkler at the 18 foot elevation of the column, (c) ceiling sprinkler density minimums as determined by the Tukwila Fire Prevention Bureau. (NFPA 13) 17: Nominal 6" transverse flue spaces between loads and at rack uprights shall be maintained in single row, double row, and multiple row racks. Random variations in the width of flue spaces or in their vertical alignment shall be permitted. (NFPA 13- 12.3.1.13) 18: Storage shall be maintained 2 feet or more below the ceiling in nonsprinklered areas of buildings or a minimum of 18 inches below sprinkler head deflectors in sprinklered areas of buildings. (WC 316.2.1) 19: Sprinklers shall be installed under fixed obstructions over 4 feet (1 2 m) wide such as ducts, decks, open grate flooring, cutting tables, shelves and overhead doors. (NFPA 13. 8.8.8.3.3) 20: All new sprinkler systems and all modifications to existing sprinkler systems shall have fire department review and approval of drawings prior to installation or modification. New sprinkler systems and all modifications to sprinkler systems involving more than 50 heads shall have the written approval of the W.S.R.B., Factory Mutual, Industrial Risk Insurers Kemper or any other representative designated and/or recognized by the City of Tukwila, prior to submittal to the Tukwila Fire Prevention Bureau. No sprinkler work shall commence without approved drawings. (City Ordinance #2050) 21: Contact The Tukwila Fire Prevention Bureau to witness all required inspections and tests. (City Ordinances #2060 and #2081) 22: Any overlooked hazardous condition and/or violation of the adopted Fire or Building Codes does not imply approval of such condition or violation. 23: These plans were reviewed by Inspector 511. If you have any questions, please call Tukwila Fire Prevention Bureau at (206)875 -4407. * *continued on next page ** doc: Cond -10/06 DO6.297 Printed: 01 -23 -2007 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 - 431 -3665 Web site: httzx / /www.ci.tukwila.wa.us I hereby certify that I have read these conditions and will comply with them as outlined. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provision of any other work or local laws regulating construction or the performance of work. Signature: doe: Cond - 10/06 Print Name: / 7 , At ;) ..?.H,...S0 Date: // ? 3/Q 7 D06 -297 Printed: 01 -23 -2007 Parcel No.: 3523049110 Address: 1109 ANDOVER PK W TUKW Suite No: Tenant: ACCU -TECH CORPORATION 1: ** *BUILDING DEPARTMENT CONDITIONS * ** 5: ** *FIRE DEPARTMENT CONDITIONS * ** doc: Conditions City Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: ci.tukwila.wa.us PERMIT CONDITIONS Steven Al. Mullet, Mayor Steve Lancaster, Director Permit Number: D06 -297 Status: ISSUED Applied Date: 08/01/2006 Issue Date: 08/24/2006 2: No changes shall be made to the approved plans unless approved by the design professional in responsible charge and the Building Official. 3: All permits, inspection records, and approved plans shall be at the job site and available to the inspectors prior to start of any construction. These documents shall be maintained and made available until final inspection approval is granted. 4: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. 6: The attached set of building plans have been reviewed by the Fire Prevention Bureau and are acceptable with the following concerns: 7: The total number of fire extinguishers required for an ordinary hazard occupancy with Class A fire hazards is calculated at one extinguisher for each 1,500 sq. ft. of area. The extinguisher(s) should be of the "All Purpose" (2A, 20B:C) dry chemical type. Travel distance to any fire extinguisher must be 75' or less. (IFC 906.3) (NFPA 10, 3- 2.1)(warehouse area) 8: The total number of fire extinguishers required for a light hazard occupancy with Class A fire hazards is calculated at one extinguisher for each 3,000 sq. ft. of area. The extinguisher(s) should be of the "all purpose" (2A, 10 B:C) dry chemical type. The travel distance to any extinguisher must be 75' or less. (IFC 906.3) (NFPA 10, 3- 2.1)(offlice area.) 9: Fire extinguishers shall not be obstructed or obscured from view. In rooms or areas in which visual obstruction cannot be completely avoided, means shall be provided to indicate the locations of the extinguishers. (IFC 906.6) 10: Extinguishers shall be located in conspicuous locations where they will be readily accessible and immediately available for use. These locations shall be along normal paths of travel, unless the fire code official determines that the hazard posed indicates the need for placement away from normal paths of travel. (IFC 906.5) 11: Fire extinguishers require monthly and yearly inspections. They must have a tag or label securely attached that indicates the month and year that the inspection was performed and shall identify the company or person performing the service. Every six years stored pressure extinguishers shall be emptied and subjected to the applicable recharge procedures. If the required monthly and yearly inspections of the fire extinguisher(s) are not accomplished or the inspection tag is not completed, a reputable fire extinguisher service company will be required to conduct these required surveys. (NFPA 10, 4 -3, 4-4) 006 -297 Printed: 08 -24 -2006 City t'Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: ci. tukwila.wa.us Steven M. Mullet, Mayor Steve Lancaster, Director 12: Egress doors shall be readily openable from the egress side without the use of a key or special knowledge or effort. (IFC 1008.1.8.3 subsection 2.2) 13: Dead bolts are not allowed on auxiliary exit doors unless the dead bolt is automatically retracted when the door handle is engaged from inside the tenant space. (IFC Chapter 10) 14: Door handles, pulls, latches, locks and other operating devices on doors required to be accessible by Chapter 11 of the International Building Code shall not require tight grasping, tight pinching or twisting of the wrist to operate. (IFC 1008.1.8.1) 15: Exit hardware and marking shall meet the requirements of the International Fire Code. (IFC Chapter 10) 16: Where storage height exceeds 15 feet and ceiling sprinklers only are installed, fire protection by one of the following methods is required for steel building columns located within racks: (a) one -hour fire proofing, (b) sidewall sprinkler at the 15 foot elevation of the column, (c) ceiling sprinkler density minimums as determined by the Tukwila Fire Prevention Bureau. (NFPA 13) 17: Nominal 6" transverse flue spaces between loads and at rack uprights shall be maintained in single row, double row, and multiple row racks. Random variations in the width of flue spaces or in their vertical alignment shall be permitted. (NFPA 13- 12.3.1.13) 18: Storage shall be maintained 2 feet or more below the ceiling in nonsprinklered areas of buildings or a minimum of 18 inches below sprinkler head deflectors in sprinklered areas of buildings. (IFC 315.2.1) 19: Sprinklers shall be installed under fixed obstructions over 4 feet (1.2 m) wide such as ducts, decks, open grate flooring, cutting tables, shelves and overhead doors. (NFPA 13- 8.6.5.3.3) 20: All new sprinkler systems and all modifications to existing sprinkler systems shall have fire department review and approval of drawings prior to installation or modification. New sprinkler systems and all modifications to sprinkler systems involving more than 50 heads shall have the written approval of the W.S.R.B., Factory Mutual, Industrial Risk Insurers Kemper or any other representative designated and /or recognized by the City of Tukwila, prior to submittal to the Tukwila Fire Prevention Bureau. No sprinkler work shall commence without approved drawings. (City Ordinance #2050) 21: Contact The Tukwila Fire Prevention Bureau to witness all required inspections and tests. (City Ordinances #2050 and #2051) 22: Any overlooked hazardous condition and /or violation of the adopted Fire or Building Codes does not imply approval of such condition or violation. 23: These plans were reviewed by Inspector 511. If you have any questions, please call Tukwila Fire Prevention Bureau at (206)575 -4407. doc: Conditions "continued on next page** D06 -297 Printed: 08-24-2006 Signature: City tit Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Fax: 206 - 431 -3665 Web site: ci.tukwila.wa.us Print Name: / ioC.c Sel $0+� doc: Conditions Steven M. Mullet, Mayor Steve Lancaster, Director I hereby certify that I have read these conditions and will comply with them as outlined. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provision of any other work or local laws regulating construction or the performance of work. Date: 9 1- 7 Y/b 6 006 -297 Printed: 08 -24 -2006 CITY OF TUKWILA Community Development Department Public Works Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http: //www. ci. tkwila. wa. us SITE LOCATION Site Address: I10ql%AVfr ara WGs / / TenantName:/¢at - C2r- p or4Pro..., New Tenant: Property Owners Name: ,ef mT� d lb�r 4- r 64-po a.ir I v.., Mailing Address: �-7d� G �f� �l t* -.-tom ! p'. fir �! f /(7 Tin t l4 Cay Name: /Ae .70rrtn Ce. Mailing Address: 1(0 C. (Al a T Sr; E -Mail Address: I'V7soet" foen & nwks.CUn, 44_ 4 Mailing Address: (1(Y) S- w. Company Name:PO f Contact Person:All -- ` Ylrtha» , E -Mail Address: 0 " Steen fen EP n •i S . G°n— Contractor Registration Number: No�k J /k a 7S E Company Name: Mailing Address: Company Name: C P S Mailing Address: / Contact Person: V r`c d Gel Building Permit No. Mechanical Permit No. Plumbing/Gas Permit No. Public Works Permit No. Project No. For we use o Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. ••Please Print** E - Mail Address: Q:UpplicationnWor s- Applieetiau On Line\ -2006 - Permit Application.doc Revised: 4-2006 bb W TUKWILA W King Co Assessor's Tax No.: 3 ✓Z'O4 "1( Suite Number: RCHITECT OF RECORD — All plans must be wet stamped by Architect of Record i{ ENGINEER OF RECORD — All plans must be wet stamped by Engineer of Record �bZo -Z�7 Floor: 7 Yes ❑..No tv1 P/61 State Zip CONTACT PERSON Day Telephone: ao6 - Q if - WET' 3"11- ^ L' 2R a t 7 City State Zip Fax Number: I I?. 3 fl 6 W r GENERAL CONTRACTOR INFORMATION - (Contractor Information for Mechanical (pg 4) for Plumbing and Gas Piping (pg 5) ) 5 7 7 nNL„ 44- -- 7RoS City State Zip Day Telephone: >D6 ` RI £ — i (P t il Fax Number: 1 a 694'0 Expiration Date: /D 2oa 7 City State Zip Contact Person: Day Telephone: E -Mail Address: Fax Number City State up Day Telephone: a) Fax Number: R ,YO '7 3 Page I of 6 BUILDING PERMIT INFORMATION — 206 -431 -3670 Valuation of Project (contractor's bid price): $ 3 7' 4 7 Existing Building Valuation: $ rack, Scope of Work (please provide detailed information): /' �C, t 1— i ., , C�t�c�1 I` I �/ t t� �� dQ tte •( Will there be new rack storage? Wes D...No (If yes, a separate permit and plan submittal will be required) Provide All Building Areas in Square Footage Below PLANNING DIVISION: Single - family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) *For an Accessory dwelling, provide the following: Lot Area (sq ft): Floor area of principal dwelling: Floor area for accessory dwelling: *Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard: Compact: Handicap: Will there be a change in use? ❑ ....Yes 'No If "yes ", explain: FIRE PROTECTION/HAZARDOUS MATERIALS: J� IA 0 ..Automatic Fire Alarm ❑..None E] ..Other (specify)ICt5 1 Will there be storage or use of flammable, combustible or hazardous materials in the building? ❑ . Yes No If' yes ", attach list of materials and storage locations on a separate 8 -1/2 x 11 paper indicating quantities and Material Safety Data Sheets. SEPTIC SYSTEM: ❑ On -site Septic System — For on -site septic system, provide 2 copies of a current septic design approved by King County Health Department. Q:tAPpliceuaaa'oma- Appheedo On tined -2006 - Permit Appacaion.doe Revised: 4-2006 bh Page 2 of 6 Existing Interior Remodel Addition to Existing Structure New Type of Construction per IBC Type of Occupancy per IBC I Floor 1,/ 900 7 / 700 F, 2"" Floor i \ 3 Floor Floors thru i Basement Accessory Structure* Attached Garage Detached Garage Attached Carport Detached Carport Covered Deck Uncovered Deck I , BUILDING PERMIT INFORMATION — 206 -431 -3670 Valuation of Project (contractor's bid price): $ 3 7' 4 7 Existing Building Valuation: $ rack, Scope of Work (please provide detailed information): /' �C, t 1— i ., , C�t�c�1 I` I �/ t t� �� dQ tte •( Will there be new rack storage? Wes D...No (If yes, a separate permit and plan submittal will be required) Provide All Building Areas in Square Footage Below PLANNING DIVISION: Single - family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) *For an Accessory dwelling, provide the following: Lot Area (sq ft): Floor area of principal dwelling: Floor area for accessory dwelling: *Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard: Compact: Handicap: Will there be a change in use? ❑ ....Yes 'No If "yes ", explain: FIRE PROTECTION/HAZARDOUS MATERIALS: J� IA 0 ..Automatic Fire Alarm ❑..None E] ..Other (specify)ICt5 1 Will there be storage or use of flammable, combustible or hazardous materials in the building? ❑ . Yes No If' yes ", attach list of materials and storage locations on a separate 8 -1/2 x 11 paper indicating quantities and Material Safety Data Sheets. SEPTIC SYSTEM: ❑ On -site Septic System — For on -site septic system, provide 2 copies of a current septic design approved by King County Health Department. Q:tAPpliceuaaa'oma- Appheedo On tined -2006 - Permit Appacaion.doe Revised: 4-2006 bh Page 2 of 6 PERMIT APPLICATION NOTES - Applicable to all permits in this application Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. Building and Mechanical Permit The Building Official may grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). Plumbing Permit The Building Official may grant one extension of time for an additional period not exceeding 180 days. The extension shall be requested in writing and justifiable cause demonstrated. Section 103.4.3 Uniform Plumbing code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OR AUTHORIZ ' GENT: / ,,,/� G Date::) /ihla4 /r 7 i44 . C eslnn Day Telephone:_g t:.o / 15 1S 1 1 ( eg — e9 -1 Print Name: r w. 74 �" '''e[ t - --I S Signature: Mailing Address: (Ion Date Application Expires: Z - -fl Date Application Accepted: $' / - 6 /v Q:Uppliceacv'Fomm- Applireaau On LineU- 2006 - Permit Applieation.doc Revised: 4-2006 bb Stat P i[i - Page 6 of 6 ACCOUNT ITEM LIST: Description Current Pmts City of Tukwila 6300 Southcenter BL, Suite 100 / Tukwila, WA 98188 / (206) 431 -3670 Parcel No.: 3523049110 Permit Number: D06 -297 Address: 1109 ANDOVER PK W TUKW Status: APPROVED Suite No: Applied Date: 08/01/2006 Applicant: ACCU -TECH CORPORATION Issue Date: Receipt No.: R06 -01339 Payment Amount: 589.64 Initials: JEM Payment Date: 08/24/2006 01:29 PM User ID: 1165 Balance: 50.00 Payee: MICHAEL J. SORENSON TRANSACTION LIST: Type Method Description Amount Payment Check 6745 589.64 BUILDING - NONRES STATE BUILDING SURCHARGE RECEIPT Account Code 000/322.100 585.14 000/386.904 4.50 Total: 589.64 9011 08/24 9716 TOTAL 589.64 doc: Receipt - - Printed: 08-24 -2006 City of Tukwila 6300 Southcenter BL, Suite 100 / Tukwila, WA 98188 / (206) 431 -3670 Parcel No.: 3523049110 Permit Number: D06 -297 Address: 1109 ANDOVER PK W TUKW Status: PENDING Suite No: Applied Date: 08/01/2006 Applicant: ACCU -TECH CORPORATION Issue Date: Receipt No.: R06 -01168 Payment Amount: 380.34 Initials: BLH Payment Date: 08/01/2006 04:05 PM User ID: ADMIN Balance: 5589.64 Payee: MICHAEL SORENSON TRANSACTION LIST: Type Method Description Amount Payment Check 6733 380.34 ACCOUNT ITEM LIST: Description Current Pmts PLAN CHECK - NONRES RECEIPT Account Code 000/345.830 380.34 Total: 380.34 2337 03/02 9716 TOTAL doc: Receipt Printed: 08 -01 -2006 Project: , — /e-c Type of Inspection: l7 ,Ce -,6/ ` Address: G �,ff- - Date Called: Speci I Instructions: Date Wanted: — z(' a.m. c equester. Phone No INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 COMMENTS: Approved per applicable codes. Corrections required prior to approval. Date: Fu $58.8a.RE( NSPECTION F REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Cali to sechedule reinspection. 'Receipt No.: Project: A L'c1,- - /-Fe l ('oeP. Type of Inspection: F /Nn ( Address: / /OS An.)adf/I Pic c-cc Date Called: Special Instructions: r✓c 3p .4-1 Date Wanted: / -17 - 0 7 a.m. ( ' Requester: / /l% Phone No: aped 3/e -vv ./.. Approved per applicable codes. �,t orrections required prior to approval. COMMENTS: .« ; ./.. 17 C .c / nib / on! f i : • fl/ r n t - �r A4` C -' l/ S, a 4 /-r -. '4,et St P INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 Inspector INSPECTION RECORD Retain a copy with permit Date: , 6' $58.00 REINSP N FEE REQUIRED. Prior to inspection, fee must be. ^ outhcenter Blvd., Suite 100. Call to sechedule reinspection. paid at 63 Receipt No.: 'Date: Project: / /406 6/ eoep., Type of Inspection: \ k--4v4 t Address: 1/05 441001/FR Pr Li-' Date Called: -"- SpeCial Instructions: m r Ft4e er /c7,9,-.1 Date Wanted: Cy Requester: ,V /k t• Pbone No: G94 6.) 8/E- EjApproved per applicable codes. INSPECTION RECORD Retain a copy with permit boL-agJ7 (206)431-367 Corrections required prior to approval. COMMENTS: /2 -- 7 -ori e e-k5 j4. /.S 2.- ei d re, Ci Pte.PL*--) 5 ea f..-fre? /at it/ n-' , s54 %et cao s e-i ar-7 rin 7- 3be/ 1 $58.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be 1-1 paid at 6300 Southcenter Blvd., Suite 100. Call to sechedule reinspection. (Receipt No.: (Date: Project: tics u - T . c N Type of Inspection: ��,� rat Crvn —KA ci— Address: //o T 4 P IA/ Suite #: Contact Person: Mike Sc2ci.is / Special Instructions: Phone No.: 206 8/8 - yYBg Needs Shift Inspection: Sprinklers: Fire Alarm: Hood & Duct: Monitor: Pre -Fire: Permits: Occupancy Type: 3 INSPECTION NUMBER —A per applicable codes. Word /Inspection Record Form.Doc INSPECTION RECORD Retain a copy with permit CITY OF TUKWILA FIRE DEPARTMENT 1/13/06 - 006- z9 PERMIT NUMBERS 444 Andover Park East, Tukwila, Wa. 98188 206- 575 -4407 n Corrections required prior to approval. COMMENTS: Jriz U/ / - Date: //y6 /1)- - Hrs.: 7 $80.00 REINSPECTION FEE REQUIRED. You will receive an invoice from t$e City of Tukwila Finance Department Call to schedule a reinspection. T.F.D. Form F.P. 113 Project: A c c t/ T tc4I Type of Inspection: 141“..-tccµ1"4, L Address: n 09 A P W Suite #: Tt nc ' t " Contact Person: M% V. E carp cros C Special Instructions: Phone No.: (706)6 lb- L B Needs Shift Inspection: Sprinklers: Fire Alarm: Hood & Duct: Monitor: Pre -Fire: Permits: Occupancy Type: 1 INSPECTION NUMBER CITY OF TUKWILA FIRE DEPARTMENT 444 Andover Park East, Tukwila, Wa. 98188 206- 575 -4407 n Approved per applicable codes. INSPECTION RECORD Retain a copy with permit — DeR0 -7 PERMIT NUMBERS Corrections required prior to approval. COMMENTS: era ?R(K ("A o. k • -- O K.. 7b LOA Date: i;iz/ /p(, Hrs.: / Inspector: 4 vu s 7 $80.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be aid at 444 Andover Park East. Call to schedule reinspection. Receipt No.: Word /Inspection Record Form.Doc - 12/2/05 Date: T.F.D. Form F.P. 85 COMMENTS: Type of Inspection: - RN C- K.. =HASP d Ncn ExmN6VISi+k -5 - O.K. TU LOAb R 2 - n -t 2E- rt.,SPE Phone No.: Zo(, S t9, if t-19)9) Permits: 0 Cot wAtt ?¢n-r - 1o W woop 7 OI . 5'a Project: Ac c u -T c 44 Type of Inspection: - RN C- K.. =HASP Address: t'oy A 0 vJ Suite #: Contact Perso 'M 5 St N Special Instructions: Phone No.: Zo(, S t9, if t-19)9) Needs Shift Inspection: Sprinklers: Fire Alarm: Hood & Duct: Monitor: Pre -Fire: Permits: Occupancy Type: INSPECTION NUMBER CITY OF TUKWILA FIRE DEPARTMENT 444 Andover Park East, Tukwila, Wa. 98188 206- 575 -4407 Approved per applicable codes. INSPECTION RECORD Retain a copy with permit - W6- ?RV- PERMIT NUMBERS `Corrections required prior to approval. d-I /pt $80.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be aid at 444 Andover Park East. Call to schedule reinspection. Receipt No.: Date: Word /Inspection Record Form.Doc 12/2/05 Hrs.: / T.F.D. Form F.P. 85 NORTHWEST The Material Handling Experts ATTN: BUILDING DEPARTMENT AND FIRE DEPARTMENT RACK INFORMATION SUPPLEMENT SITE ADDRESS: 1109 Andover Park West TENANT NAME: Accu -Tech Corporation DATE: July 26, 2006 APPLICANT: Mike Sorenson / (206) 818 -4488 1100 SW 7th St Renton, WA 98055 (425) 255 -0500 ph (425) 228 -6946 fax 1. Load application and rack configuration drawings attached. 2. Attached plans and engineering detail the rack locations, dimensions, and specifications. 3. Stamped engineering calculations attached. 4. Vertical members of storage racks are designed and installed so that failure of one vertical member will not cause collapse of more than the bay or bays directly supported by that member 5. Commodities stored in racks: Wiring f3 cabling materials for communications ft physical (building) security. 6. Sprinkler System Information: .39 GPM / 5600 square feet. 2576 gpm ® 69.5 psi 7. Smoke and heat vents: In place but not required for this size of project. RECEIVED 8. Building exits indicated on attached drawings. CIrYCF AUG p 1 2065 PERMIT CENTER NORTHWEST a Ater a an Inl g E tree 1100 5. W, 7"' St Renton. WA 98057 Phone: 425 -25 #500 xtn.112 Fax: 425 -228 -6946 800 - 426 -3888 Fax Cover To: Mr. Al Metzler Co: CC: Fax: 206 -575 -4439 Re: 4252286946 NW HANDLING SYS Tukwila Fire Dept. Accu -Tech #1)06 -297 743 P01 AUG 07 '06 11:36 From: Mike Sorenson Co: NW Handling Systems Fax: (425)228 -6946 Date: 8/7/2006 Total Pages: 3 Al- Customer describes the product mix and packaging as the following: 1 .-2% of materials are on plastic reels, stored In cardboard boxes on wood pallets on wire mesh rack decking. 35% Cabling is insulated, stored on wooden reels, stored in cardboard boxes and on wood pallets on the floor or on wire mesh rack decking. 25% Cabling is insulated stored on wooden or steel reels on open deck rack or on the floor. ki ' 15% Cable pathway is non insulated steel, stored on wood pallets and mfg. Packaging (cardboard). On the floor or on wire mesh rack decking. 25% Connectivity components are insulated materials, stored in cardboard boxes, on - wood pallets or directly on wire mesh decking. Also, please see the following copy of a letter to LA County Fire Dept. for a similar facility in So. Cal. Please be sure to call or email if you have any questions. Thanks. IMsorensonanwhs.com www.nwnssam RECEIVED AUG 07 12006 PERMIT CENTER FCC 2filir 4252286946 NW HANDLING SYS Accu -Tecli We're Known by the Companies We Keep September 23, 2005 Los Angeles County Fire Department Fire Prevention Division 5823 Rickenbacker Road Commerce, CA 90040 Subject Commodity and Storage Information for Amu -Tech Corporation 16831 Knott Avenue La Mirada, CA 90638 To Whom It May Concern Please accept the information listed below in addition to the drawings and high piled storage analysis provided for our High Piled Storage Permit. PRODUCTS STORED: Electronic wire & cable, connectivity components and network products for voice, data, video and security applications. CONTAINERS AND PACKAGING MATERIALS: Electronic wire & cable sheathed in Plenum rated insulation are on wood or metal spools. Some spools are in cartons and there are times when wooden spools are stored empty. Connectivity components and network products are packaged in original manufacturer's packaging that includes corrugated cardboard. STORAGE METHOD: Wire & cable is stored on wood pallets in single and double row racks. The pallets are stretch wrapped on the sides but not over the top. Connectivity components and Network products are stored and shelved in their original packaging and/or placed into corrugated cardboard boxes for identification and consolidation. Box dimensions are 24 "x 10 "x l 8" or 24 "x 15 "x 18" with open top construction. STORAGE HEIGHT: Maximum Storage Height- 22'. HIGH PILED STORAGE AREA: The total storage area for high piled storage (ova 12') is 9,640 square feet. Adams, GA Charlotte. NC Pt. Lauderdale, PI, New York. NY Austin. TX Charleston, SC Greenville, SC Norfolk. VA Baltimore, MD Columbus, OH Houston, TX - Philadelphia, PA Birmingham, AL Deltas. TX Kanas City, KS Phoenix. AZ Boston. MA Detroit, MI Nashville, TN Raleigh, NC 784 P02 RUG 21 '06 08:57 Richmond, VA San Antonio, TX Tampa. FL Como= Office 200 Hembree Park Drive Roswell, GA 30076 Telephone 770.7402240 Fax 770.740.2260 Toll Ftoe.888.222.8832 www.accudech.com RECEIVE AUG 07 2006 PERMIT CENTE tijr Z�t1- 4252286946 NW HANDLING SYS 784 P03 AUG 21 '06 08:57 Accu-Tecli We're Known by the Companies We Keep AISLE WIDTHS: High Piled Storage Area: Smallest Aisle — 5' -5" SPRINKLER DESIGN: Existing Ceiling Sprinkler Density:.45gpm Sprinkler Head: 17/32" orifice Please feel free to contact me at 770 -740 -2240 ext 1162 if further information is required. Respectfiilly, John Wiley, Vice President Operations Atlanta, GA Charlotte. NC Ft Lauderdale, FL Austin, TX Charleston, SC Granville, SC Baltimore, MD Columbus, OH Houston, TX Birmingham. Al. Dallas, TX Kansas City, KS Boston, MA Detroit, MI Nashville, TN Design Area: 3000 sq. ft. Temperature Rating: 286 °F New York. NY Norfolk VA Philadelphia, PA Phoenix. AZ Raleigh. NC Richmond, VA San Antonio, TX Tampa, FL Corporate Office 200 Hemline Park Drive Roswell, OA 30076 Telephone 770.740.2240 Fax 770.740.2260 Toll P w.888.222.8832 www,accu4cchtom By G. OHANIAN DATE. 7 - 27 - 06 SUBJECT STRUCTURAL CALCULATIONS OF STORAGE RACKS FOR: ACCU —TECH CORPORATION 1109 ANDOVER PARK WEST TUKWILA, WA. 98188 PER IBC 2003 EDITION STORAGE RACKS CAPACITY: AS SHOWN ON ELEVATIONS CALCS. 1 THRU 6 DRAWINGS: RD -11183 RAdK DEORIN & ENWINEERINd do. 412 WEST BROADWAY, RUM #204 LENDALE, dA. 91204 TEL:(818)240 -3810 FA%:(818)240 -3813 EXPIRES 12 - 26 - 07 SHEET NO 1 JOB NO. RD - 11183 CITY OF AU u e I zoos PERMIT CENTER pOb•Z°1'i BY " G. OHANIAN DATE 7 -27 -06 SUBJECT 144" 144" BEAM BEAM M 144 "x1.7 K -31 "K 8 3000 jJ/ LEVEL TYPE "A" 144" 3000 #/ LEVEL TYPE "D" 1 S 3 0 "K = 1.02<1.59 A 384 SxWx x L3 = . "< 14 = RACK DES1dN & ENGINEERING CO. 412 WEgT BROADWAY, QUITE #204 LENDALE, GA. 91204 TEL:(818)240 -3810 FAX:(818)240 -3813 2 3/4" 9 8" 44" 1 44 ",48 (A) 3000 fr/ LEVEL TYPE "B" I x =4.89 S =1.59 F Y= 5 KSI. SIDE VIEW 3000 #/ LEVEL +25X IMPACT LOAD 1700 #1 BEAM SHEET NO JOB NO. RD -11183 144" 1 3000 fr/ LEVEL TYPE "C" ;. By •• G. OHANIAN DATE 7 - 27 - 06 SUBJECT n 44 (E & G) 148" (F JEAN M= 961x1.7 -20 "K 8 S R = 3 0 "K = .68 <.85 A- xWxL - 144" 1500 #/ LEVEL TYPE "E" SIDE VIEW =. 384x1 xE 32 "< 180 - 53" 1 RACK DESIdN & ENdINEERINd CO. 412 RE{ T BROADWAY, (QUITE �204 LENDALE, CA. 91204 TEL:(818)240 -3810 FAX:(818)240 -3813 96" 1500 #/ LEVEL TYPE "F" 3000 #1 LEVEL +25% IMPACT LOAD 1700 #/ BEAM I =1.84 5, =.85 F Y= 50 CI. SHEET NO 3 JOB NO. RD - 11183 95" 1500 #/ LEVEL TYPE "G" .. BY •G. OHANIAN DATE 7 -27 -06 SUBJECT SFISMIC DESIGN _ S DS xl �— Rx1.4 STRESS 1 =1 R =6 MOM. CONN. R =4 BRACED S _.85 W =D. L.+3 L. L. LOAD PER COLUMN TYPES "A" & "B" L.L. =_-x 3x3 K =3K 3 2ca. W =.1 O. L 3 3.1 K y _ •85x1 _ , 31 K lAKG1T• 6x1 x3.1 ✓ _.85x1x3.1_ TRANS. 4x1.4 TYPE "C" & "D" L.L.= 3 x 423 o 4 K W =.1 D. L 4 LL 4.1 K ✓ _.85x1x4.1_.41 LONGIT 6x1.4 v = .85x1x4.1 _ 62 K TRANS. 4x1.4 • TYPE "E ". "F" & "G" L.L.= 3 x 7x 2 3. K DDL W =.i 3.5 3.6 K v _ .85x1x3.6 _ 36K LONGIT. 6x1.4 ✓ _ .85x1x3.6 =. 54K TRANS. 4x1.4 IBC 2003, SEC. 2208 RACK DEOION & ENOINEERIN(# CO. 412 WE BROADWAY, SUITE #204 LENDALE, DA. 91204 TE1:(818)240 -3810 FAX:(818)240 -3813 M — .36Kx34" _ COL. 2 S =1.27 (USGS MAP) Sws =1.27 (EQ. 16 -38) S DS = 3 x 1.27 =.85 (EQ. 16 -40) LONGIT. SEISMIC .31 K 13'K .41 K 1O 'K SHEET NO 4 JOB NO. RD -11183 • By ' 'G. OHANIAN DATE 7 - 27 - 06 SUBJECT COLUMN ANALYSIS 1n COMBINED STRESS RATIO P + M = 81 + _ . 93<1.33 a ax Fy =50 KSI A =.78 S =.80 r =1.2 r =1.1 BASE PLATE ANCH. TENSION = 13— (6.1x3') =.62 K ANCHOR SHEAR = .31 = 16 K (2) -1/2 "0 HILT! KWIK BOLT 3 ANCHORS ESR -1385 OR APPROVED EQUAL. DESIGNED FOR 1/2 STRESS. (NO SPECIAL INSPECTION REQ'D) MOMENT AT BEAM CONNECTION 7/16"0 RIVET A =.1 Fy = 79 KSI Va = .1x79x.4 = 3 Ma =3Kx4 "x1.33 = 16 K CONN. RACK DEF11dN Sc ENdINEERINd d0. 412 WET BROADWAY, RUM #204 ((}}LENDALE, DA. 91204 TEL:(818)240 -3810 FAR:(818)240 -3813 2 PIN CONN. .K1 _ 86x1.7 =122 rx 1.2 KI =.1752 =47 Y • Max = S =24 "K Fe = ) 2 -19 z Fn =Fe =19 KSI P =FxA= 15 P P SK a 1.92 — 31K 13" SHEET NO 5 JOB NO. RD -11183 7 3/4 "x5 "x3/8" BASE PLATE BY . • G. OHANIAN DATE. 7 -27 -06 SUBJECT OVERTURNING M .62 "x.5x1.15 =144 " K MR = 4.1 K x44" = 180 "K NO UPLIFT LOAD TO DIAGONAL P= .62Kx2x 44 =1.6 Fy =50 KSi A =.31 r =.48 Q =.74 L= 58" CHECK WELDS 1/8" WELD 1.5" LONG EACH SIDE (3" TOTAL) 3x.125x.707x70x.3 = 5.7 K CHECK SLAB 4100 4.1 °' 1000 - F = 10.6 Ksi P = 3.3 K 4.1x144 =590 ° " 590 =24" M= ( )x1000x 2 x12 = 1500 "# S 12x6 = 72 6 1500 _ 21 <1.6 ./2000 =72 72 RAdK DESIC#N & ENC INEERIN(I do. 412 WE BROADWAY, BUTTE #204 LENDALE, CA. 91204 TE14(818)240 -3810 FAX:(816)240 -3813 BOTH SIDES TYP TOP LEVEL LOADING =.15K x2x202 "= 60 .K M MR =1.1Kx44 " = 48 " K UPLIFT = 60 -48 = . 27 K 44" 4100~ SHEET NO 6 JOB NO. RD - 11183 6" CONCRETE SLAB 2000 PSI. CONC. 1000 PSF. SOIL 01-02 -2007 MIKE SORENSON 1100SW7ST RENTON WA 98057 RE: Permit No. D06 -297 1109 ANDOVER PK W TUKW Dear Permit Holder: City of Tukwila Steven M. Mullet, Mayor Department of Community Development Steve Lancaster, Director • In reviewing our current records the above noted permit has not received a final inspection by the City of Tukwila Builtling Division. Per the International Building Code and/or the International Mechanical Code, every permit issued by the Building Division under the provisions of this code shall expire by limitation and become null and void if the building or work authorized by such permit is not commenced within 180 days from the date of such permit, or if the building or work authorized by such permit is suspended or abandoned at any time after the work is commenced for a period of 180 days. Based on the above, you are hereby advised to: Call the City of Tukwila Inspection Request Line at 206 - 431 -2451 to schedule for the next or final inspection. • This inspection is intended to determine if substantial work has been accomplished since issuance of the permit or last inspection; or if the project should be considered abandoned. If such determination is made, the Building Code does allow the Building Official to approve one or more extensions of time for additional periods not exceeding 90 days each. Extension requests must be to writing and provide satisfactory reasons why circumstances beyond the applicants control have prevented action from being taken. In the event you do not call for the above inspection and receive an extension prior to 02/27/2007 , your permit will become null and void and any further work on the project will require a new permit and associated fees. Thank you for your cooperation in this matter. Sincerely, xc: Permit File No. tr06.297 • 6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone: 206-431-3670 • Fax: 206- 431 -3665 August 2, 2006 Mike Sorenson 1100 SW 7 Street Renton, WA 98057 Dear Mr. Sorenson: Sincerely, k hi Brenda Holt, Permit Coordinator Enclosures p:OBrenda\D06 -219 — incomplete la #1.doc bh City of Tukwila Department of Community Development Steve Lancaster, Director RE: Letter of Incomplete Application # 1 Development Permit Application D06 -297 Accu -Tech Corporation —1109 Andover Pk W Steven M. Mullet, Mayor This letter is to inform you that your application received at the City of Tukwila Permit Center on August 1, 2006, is determined to be incomplete. Before your application can continue the plan review process the following items need to be addressed: Building Department: Allen Johannessen, at 206 -433 -7163, if you have questions concerning the attached: Please address the above comments in an itemized format with applicable revised plans, specifications, and/or other documentation. The City requires that four (4) complete sets of revised plans, specifications and/or other documentation be resubmitted with the appropriate revision block. In order to better expedite your resubmittal a 'Revision Submittal Sheet' must accompany every resubmittal. I have enclosed one for your convenience. Revisions must be made in person and will not be accepted through the mail or by a messenger servke. If you have any questions, please contact me at the Permit Center at (206) 431 -3670. 6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone: 206 -431 -3670 • Fax: 206- 431 -3665 Determintion of Completeness Memo Date: August 3, 2006 Project Name: ACCU -TECH Corporation Permit 0: D06.297 Plan Review: Allen Johannessen, Plans Examiner A Building Division has deemed the subject permit application incomplete. To assist the applicant in expediting the Department plan review process, please forward the following comments. PLAN SUBMITTALS: (Min. size 11x17 to maximum size of 24x36; all sheets shall be the same size). (If applicable) Structural Drawings and structural calculations sheets shall be original signed wet stamped, not copied.) 1. The plans s how storage rack isles tight to what appears to be the back South exterior wall. Code requires: the path of egress travel along a means of egress shall not be interrupted by any building element other than a means of egress component. Obstructions shall not be placed in the required width of a means of egress. Relocate racks to allow for an approved unobstructed egress pathway from the back warehouse to an exit. (IBC 1003.6) 2. Identify emergency lighting, emergency lighted paths and identify lighted exit signs. (IBC 1006.1, 1006.2, 1006.3 & 1006.4) Should there be questions concerning the above requirements, contact the Building Division at 206 -431 -3670. No further comments at this time. ACTIVITY NUMBER: D06 -297 DATE: 08 -09 -06 PROJECT NAME: ACCU -TECH CORPORATION SITE ADDRESS: 1109 ANDOVER PK W Original Plan Submittal X Response to Incomplete Letter # 1 Response to Correction Letter # Revision # After Permit Issued DEPARTMENTS: 0 � Buirttdision Public Works ❑ DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete Comments: APPROVALS OR CORRECTIONS: Approved ❑ Notation: REVIEWER'S INITIALS: Documents/routing slip.doc 2-28-02 - PERMIT COORD COPY `-' PLAN REVIEW /ROUTING SLIP Fire Prevention Structural Incomplete ❑ TUES/THURS ROU ING: Please Route Structural Review Required REVIEWER'S INITIALS: ❑ Permit Coordinator ❑ DUE DATE: 08-10-06 DATE: DATE: Planning Division Not Applicable ❑ Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: No further Review Required DUE DATE: 09 -07 -06 Approved with Conditions ❑ Not Approved (attach comments) ❑ Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: ACTIVITY NUMBER: D06 -297 DATE: 08 -01 -06 PROJECT NAME: ACCU -TECH CORPORATION SITE ADDRESS: 1109 ANDOVER PK W X Original Plan Submittal Response to Incomplete Letter # Response to Correction Letter # Revision # before Permit Issued DEPARTMENTS: 652 Bull g IlTvisio IYTYI Public Works ❑ Complete U Documents/routing slip.doc 2 -28-02 PERMIT COORD COPY PLAN REVIEW /ROUTING SLIP APPROVALS OR CORRECTIONS: Air IVG DT Fire Prevention Structural DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Incomplete Planning Division Permit Coordinator DUE DATE: 08 -3 -06 Not Applicable ❑ Comments: Permit Center Use Only `r INCOMPLETE LETTER MAILED: 0 LETTER OF COMPLETENESS MAILED�: Departments determined incomplete: Bldg 0 Fire ❑ Ping ❑ PW ❑ Staff Initials: / TUES/THURS ROUTING: Please Route ❑ Structural Review Required ❑ No further Review Required ❑ REVIEWER'S INITIALS: DATE: DUE DATE: 08 -31 -06 Approved ❑ Approved with Conditions ❑ Not Approved (attach comments) ❑ Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments Issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.cltukwila.wa.us Revision submittals must be submitted in person at the Permit Center. Revisions will not be accepted through the mall, fax, etc. Date: tAL. I / getv Plan ChecWPermit Number:)r 6 1 ❑ Response to Incomplete Letter if ❑ Response to Correction Letter # ❑ Revision # _ after Permit is Issued ❑ Revision requested by a City Building Inspector or Plans Examiner Project Name: AC—C— o —^C AMA 009r C hi'p. Project Address: I �f�`( A4Ac4pt)9r c. li 1 I L' Contact Person: le Scre vczw Phone Number &p(, — RI $-- 4 ( 83 Summary of Revision: r Per rem riex,.S e gort§ frul _ r Mfr. r tz)L Eire Ian ( emu (1P.rb `piton r-c A -s A--P Sheet Number(s): "Cloud" or highlight all reas of revision including date of revision Steven M Mullet, Mayor Steve Lancaster, Director `tn"\s " eel VL1ei c-v Received at the City of Tukwila Permit Center by: CRY OF TUKWILA El Entered in Permits Plus on AUG 0 9 2006 lapplicationslfonns- applications on Iine4evision submittal Created: 8 -13 -2004 PERMIT CENTER Revised: Determintion of Completeness Memo Date: August 3, 2006 Project Name: ACCU -TECH Corporation Permit #: D06-297 Plan Review: Allen Johannessen, Plans Examiner A Building Division has deemed the subject permit application incomplete. To assist the applicant in expediting the Department plan review process, please forward the following comments. PLAN SUBMITTALS: (Min. size 11x17 to maximum size of 24x36; all sheets shall be the same size). (If applicable) Structural Drawings and structural calculations sheets shall be original signed wet stamped, not copied.) The plans show storage rack isles tight to what appears to be the back South exterior wall. Code requires: the path of egress travel along a means of egress shall not be interrupted by any building element other than a means of egress component. Obstructions shall not be placed in the required width of a means of egress. Relocate racks to allow for an approved unobstructed egress pathway from the back warehouse to an exit. (IBC 1003.6) 2. Identify emergency lighting, emergency lighted paths and identify lighted exit signs. (IBC 1006.1, 1006.2, 1006.3 & 1006.4) Sh o Should there be questions concerning the above requirements, contact the Building Division at 206-431 -3670. No further comments at this time. W ` 0 3 °I a,sln RECEIVED CITY OF TUKWILA AUG 0 9 2006 PERMIT CENTER License Information License NORTHWH275JF Licensee Name NORTH WEST HANDLING SYS INC Licensee Type CONSTRUCTION CONTRACTOR UBI 600051641 Ind. Ins. Account Id 32999900 Business Type CORPORATION Address 1 1100 SW 7TH ST Address 2 City RENTON County KING State WA Zip 980552939 Phone 4252550500 Status ACTIVE Specialty 1 GENERAL Specialty 2 UNUSED Effective Date 4/6/1973 Expiration Date 10/9/2007 Suspend Date Separation Date Parent Company Previous License Next License NORTHHS963ND Associated License Bond Information Bond Bond Company Name Bond Account Number Effective Date Expiration Date Cancel Date Impaired Date Bond Amount Received Date #6 TRAYS 81S103354822BCM 10/01/2001 Until Cancelled 01/01/1980 512,000.00 10/09/2001 Business Owner Information Name Role Effective Date Expiration Date FRANCK, JAMES 1 01/01/1980 THOMAS, KEVIN A 01/01/1980 KOSTY, CLARK R 01/01/1980 Look Up a Contractor, Electric n or Plumber License Detail Page 1 of 3 Washington State Department of Labor and Industries General/Specialty Contractor A business registered as a construction contractor with L&I to perform construction work within the scope of its specialty. A General or Specialty construction Contractor must maintain a surety bond or assignment of account and carry general liability insurance. https: // fortress. wa. gov /lni/bbip /printer.aspx ?License= NORTHWH275JF 08/24/2006 x x