HomeMy WebLinkAboutPermit L99-0038 - DWINELLS VISUAL SYSTEMS - SPECIAL PERMISSIONL99 -0038
SLEEP -TRAIN
235 Strander Blvd.
)
City of Tukwila
John W Rants, Mayor
Department of Community Development Steve Lancaster, Director
STAFF REPORT TO THE DIRECTOR
OF THE
DEPARTMENT OF COMMUNITY DEVELOPMENT
PREPARED JUNE 3,1999
FILE NUMBERS L99 -0038 (Special Permission Bedroom Superstore Wall Sign)
S99 -047 (Permanent Bedroom Superstore Wall Sign)
APPLICANT
REQUEST:
LOCATION:
COMPREHENSIVE
PLAN DESIGNATION:
ZONE DESIGNATION:
SEPA
DETERMINATION:
STAFF:
ATTACHMENTS:
A. Site Plan
A. Wall Elevations
B. Sign Detail 1
C. Sign Detail 2
E: \99 \BDRMSUP.DOC
Dwinell's Visual Systems
Approve a 50% wall sign area increase based on a doubling of the
building setback., per TMC 19.32.140(A) and 19.32.150. Total
sign area would be 92.45 s. f., which is less than the 6% EBF
limitation (140.4 s. f.).
406 Evans Black Drive, Tukwila, WA.
Tukwila Urban Center (TUC)
Tukwila Urban Center (TUC)
None required.
Vernon Umetsu
6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • (206) 431-3670 • Fax (206) 431-3665
z
:F- w
6
U O'>
'CO CI
W=
o
2
gJ!
El =a.
I- al
z�;
o.
UJ
;0 :=,
;o
F=- U
=
w z.
O~
z
Staff Report to the
Staff Report to the Director of the Department of Community Development
L99 -0032
Page 2
FINDINGS
VICINITY /SITE INFORMATION
Project Description
z
w
J U:
UO:
N °.
W=
J
wO
a.Q
52 d
The proposed sign area is 92.2 square feet. The exposed building face (EBF) associated = w
with the sign is 2,340 s. f. (= 18'x130'). The maximum sign area increase allowed is z
140.4 s. f., based on 6% of the wall face where it will be mounted. z o
11.1 u
The sign would be internally lit. v
O N'
Background w w
'-V.
Initial application materials indicated a nuch smaller building and the need for a 30+ s. f. O`
sign area increase. Staff research of historic files provided more accurate information on
building size and the need for only a 2.45 s. f. area increase. The applicant chose to
procede with the sign area increase application rather than reduce the sign area.
The applicant requests approval of a special permission wall sign as shown in
attachments A through D. This would allow increasing the wall sign area by 2.7 %, based
on a doubling of the minimum building setback per TMC 19.32.140(A)2.
The sign faces eastward toward Andover Park East. It spans a juncture where the 18 ft.
high portion of the building steps back 35 feet behind a one story building area
(Attachment A). The eastern end is attached to the 18 ft. high building wall while the
western end is supported by a pole on the one story roof (attachments B through D).
wz
0—
O
z
All trusswork will be fully enclosed and no portion of the sign will extend above the 18
ft. high wall per TMC 19.28.010(4).
REVIEW CRITERIA FOR SIGN AREA INCREASE
The Director of the Department of Community Development is authorized to approve sign area
increases of no more than 50 %, for each doubling of the required minimum setback distance for
the wall upon which a particular sign is to be placed, as a Type 2 permit (TMC 18.104.O10C). In
no case may the sign area exceed 6% of the total "exposed building face ". (TMC 19.32.140A.2
and 19.32.150).
The proposed sign area increase may be authorized subject to satisfying the required criteria.
The criteria to authorize a sign area increase are shown in smaller "bold italics" letters, followed
by City staff findings. Applicant submitted materials are presented in attachments A, B C and D.
\ \TUK2 \SYS \HOME \V ERNON\99 \bdrmsup.doc
Staff Report to the
Staff Report to the Director of the Department of Community Development
L99 -0032
Page 3
The sign area increase is no more than 50% for each doubling of the required minimum setback distance for the
wall upon which a particular sign is to be placed (TMC 19.32.140A.2)
The proposed sign area is 92.45 square feet. The exposed building face for all north
elevation walls is 2,340 s. f. ( =18'x 130'. This is would allow a basic wall sign area of
90.2 square feet'.
The sign is located in the TUC (Tukwila Urban Center) zone, where a 15 building setback
would apply. The sign and the wall it is mounted 35 ft. from the property line. This is
twice the minimum required setback.
The proposed sign area of 92.45 s.. f. would require one 50% increase based on providing
twice the the minimum setback distance, or 30 feet.
In no case shall sign area exceed 6% of the total "exposed building face': (TMC 19.32.140A.2 and 19.32.150)
Six percent of the west wall's 2,340 s. f. EBF is 140.4 square feet. The requested 92.45 s.
f. sign less than 140.4 square feet.
CONCLUSIONS
Based on the above Findings, Staff concludes the following;
A. The fifty percent area increase which would require a 30 ft. building setback. This is
exceeded by the actual 35 ft. setback.
B. The requested increase would not result in a sign which exceeds the six percent of EBF
limitation on area increases
DECISION
Based on the above Findings and Conclusions, the requested sign area increase is herewith
approved, subject to receiving a building permit.
Steve Lancaster, Director Date
Department of Community Development
Basic Sign Area Calculation per Table 1, TMC 19.32.140A.2:
65 s.f. + (0.03 X ( EBF of 2,201 s.f. —1,500 s.f. = 701 s.f.) = 86 s.f.
E: \99 \bdrmsup.doc
z
■ �w
00
w=
JE
U W'
W0
u.¢
w
= d.
1--0
Z
n p.
U
O N:
0 i-
w w:
01
W z;
U CO;
;O
DwineIIt
VISUAL SYSTEMS
Since 1940
814 Sixth Ave. S.
Seattle, WA 98134 -1304
1- 800 - 477 -SIGN
(206) 292-8865
FAX (206) 682 -4781
May 18, 1999
City of Tukwila
RE: Bedroom Superstore - Sign Permit #S99- 047,4
O 07.38
The building sign on the north elevation has a facade area of 1,530
square feet. The allowable sign area is 65.9 square feet. The
proposed sign area is 86.75 square feet.
We are requesting the 50% increase based on the more than double
setback of 15' from the property line. The setback from the
property line is 38 to the building. In addition, the sign at 86.75
will be Tess than the 6% (91.8) maximum allowed.
Please contact me if you have any questions.
Sincerely,
Bonnie O'Meara
Permit. Technician
RECEIVED
CITY OP TUKWILA
MAY 1 8 1999
PERMIT CENTER
Designers, Manufacturers and Installers of Custom: Slgnage zi/ Awnings ,V Electronics y' Vinyl Graphics
:: ••.
APR-03-99 08:34 AM 8 S S
22065733849
P.03
ArrAcmmemr
144
41,
File: L 99 -0038
5mm Drawing
#1 -2
�
I a
'J U
.o O;
5-, $: zzo'.,- )1V
S r75)
'20'0" II O — 6,8 t 1 17,55)=
•
Jeb Nam _ •
The Bedroom superstore
rY Joti''l:ocatlori:
THEBEDR.CDR
1 of 1
ASS %spe�rson
Jeff Cooper
S/F illuminated display
Scale: 1/2" =
& install:
EXISTING 2" SO.
II TUBE FRAME
3"
DECORATION
'Head Logo•.
Face - Ivory 230.005 vinyl
Hair • Orange 23044
Eyes • Exposed white Acryie
Pupils- Blue 230-127
Outline, Trim & Eyebrows - Black 230.12 vinyl
Register mark Dark Magenta 220163 Applied to raceway
METAL FAB:
Fabricated alum. rtes. and backs
Fabricated alum. raceway
5' Rtn. on logo
3' Rtn. on OPC letters
FACES:
'Head logo'
White Acrylic, Blacktrimcap
PAINT:
'Head Togo'
Paint inside of channel Dupont #508 white (or match) flat finish
Letters:
Paint inside of OPC letters to match PMS #213c Magenta, Gloss finish
All channel retums paint Gloss black
RACEWAY:
Paint semi -gloss white
ILLUMINATION:
'head logo'
white #6500 grid neon, 15mm, 60ma
'the'
2/T Voltarc Powder blue/Neon gas 15mm 60ma
'bedroom'
2/T Voitarc Powder blue /Neon gas 15mm 60ma
#200 Housings, Transformers in raceway
1/2" X 5" bolts through steele tube frame
(8) top, (8) bottom
Ap_.s
S" cA.f
Landlord:
Date:
Customer:
Date:
�`�Drawln " "" Sca1e.�_
As Noted
This original design
Is protected under
Federal Copyright Laws.
No reproduction is allowed.
Storefront elevation
No Scale
VISUAL SYSTEMS
ft/ 814 6th Ave. S. Seattle, Wa. 98134 -1304 it/ National: 1- 800477 -7446 Ph: (206) 292 -8865 Fax: (206) 682 -4781
Sl Ell
!' I111 11 111111111111Illlllllllll111 111111111.1111.1111111.11 III lllllll111ll�llllll11ll llll
1111fI1$1 111.Iiiii1 i i0,0.L1.011)±11
AIrACRM It' T
4
I'I
0. Inch.'.
• 1 'I..
,Illill^ III�IIIi. IIIIIIIIII�IIIIIIIIIIIIIIIIIII�IIIIIIIIIIILIIIIIIIIIIIIIIIII �I` Illlllll�llllllllllllll�llll�llll�lillllll. 111111 .11111�I{1111141�ILlllllli�.