Loading...
HomeMy WebLinkAboutPermit L97-0062 - PARKWAY SUPERCENTER - PARKING VARIANCEL97 -0062 PARKWAY SUPERCENTER 17300 Southcenter Pkwy. �.,"..., ;; .. _ .., . .............�:li r.,,.�:..,.�.,!:.,a �..:f::i:.[..:. ,,..u....,:.:i,�a�;:. , i..w i:'' , :..,.:,�:s.a .rv:,.r „ 1 .:�•,s..,.:.<u.•.5k�;;:::.,.,la �a:•;_...; a.;; t- a:w �SL�; �a. �i,&., +i:�.,;:x,[it:;,.::;i+,,�,;.!'� ;,fir. F�si,.c4*9. BENNER STANGE ASSOCIATES / ARCHITECTS, P.C. CITY ir TUKWILA DEPARTMENT OF COMMUNITY DEVELOPMENT FAX NUMBER: (206) 431-3665 COMPANY: DEPARTMENT: DATE: / FROM: TITLE: DEPARTMENT: . . FAX NO. g 670 - 093 NUMBER OF PAGES TRANSMIITED, INCL. THIS COVER SHEET: ,3.r/ /,X4,07M. .4,7X teXCA 3 SENT BY (INITIALS): eiVIANIYA, oT-- \47 ar-4. -1-17 prz..- k)U c)as--% c-v-‘ o p Q$--- J9DC(jro-5 Ai 0 (-0,_ • . ' ('&— i r0-.47( o 1-7 o I IF THIS COMMUNICATION IS NOT CLEARLY RECEIVED, PLEASE CALL: DEPARTMENT OF COMMUNITY DEVELOPMENT 6300 Southcenter Boulevard, Tukwila WA 98188 • ta Fes; 1908 City of Tukwila John W. Rants, Mayor Department of Community Development Steve Lancaster, Director MEMORANDUM TO: Steve Lancaster, DCD Director FROM: Nora Gierloff, Associate Planner RE: Proposed Administrative Parking Variance L97 -0062 DATE: October 3, 1997 REQUEST The architect for the upcoming Parkway Supercenter redevelopment has submitted a request for an administrative parking variance per TMC 18.56.140 with the attached parking study. The variance is to cover the main portion of the mall and outbuildings (Parcel A), but not the new theater and two new restaurants on the existing Pavillion Mall site. The proposed redesign of the site includes the demolition of the westward building projection, thereby significantly increasing the number of parking stalls. The current proposal would provide 1,740 parking stalls, which is 93 fewer than the 1,833 required by code. This is a deficiency of 5 %, within the 10% threshold for an administrative variance. DECISION CRITERIA Parking variances may be allowed after the applicant demonstrates that the project will meet the following criteria: I) All shared parking strategies are explored The project is under one ownership and surrounding businesses do not have excess parking that could be safely accessed by customers of the Parkway Supercenter project. Therefore shared parking is not an option. II) On -site park and ride opportunities are fully explored The vast majority of the parking is required by retail and restaurant customers, not employees, so park and ride strategies would not effectively reduce parking demand. III) The site is in compliance with the City's commute trip reduction ordinance or, if not an affected employer as defined by the City's ordinance, agrees to become affected. The individual businesses on the site do not trigger CTR compliance because of their size and hours of operation. However, the site as a whole will have to become an affected employer as a condition of the variance. 6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • (206) 431-3670 • Fax (206) 431-3665 . z 11— JV: 00 .w = J w 0, 2 u--J N D. _ v —w I— 0. Z 0; pfs 0 =, 0 H. wW 0: ii.i z; O I— z IV) The site is at least 300 feet away from a single-family residential zone The site meets this requirement. V) A report is submitted providing a basis for less parking and mitigation necessary to offset any negative effects The parking study analyzes hourly peak parking demands for the center (retail and restaurant uses) and concludes that a peak requirement of 1484 stalls would occur at 2:00 and 3:00 on Saturday. This is 349 fewer than required by code and 256 fewer than the 1,740 stalls that are proposed. CONCLUSION I recommend that a variance in parking requirements for 180 stalls (9.8%) be granted for the Parkway Supercenter project. This additional amount is justified by the parking study and will allow some flexibility for changes during design review and in the tenant mix. As a condition of approval the development must agree to become a CTR affected employer. Reviewed and approved with the stated condtion by Tukwila DCD Director, on Cpc---6%-3f2x- 7 , 1997. • - OCT 03 '97 08:35 BROWN&ASSQCIATES Christopher Brown tif Associate& 879 Painicr Avenue N.. Suite A -201 Renton, WA 98055-1380 (206) 772 -1188 Fax 772-4321 P.1 Ms. Nora Gierloff Department of Community Development City of Tukwila 6300 Southcenter Boulevard Tukwila, WA 98188 Re: City of Tukwila Parkway Supercenter Parking Analysis Fax Transmittal dated 9/26/97 Dear Ms. Gierloff: October 1, 1997 I have received a copy of the subject fax transmittal and wish to confirm the following. 1. The parking then available at the time of our study was 1,740 stalls. You may note that as of October 1st there are an additional 6 stalls but, as a minor increase they do not effect the study conclusions. 2. The $200 review fee was sent by Mr. Stange last week and should be on hand. If you have not yet received it, please call me and I'll pay it so there.is no delay . in your review. I have been advised that Parcel 'B' now meets the parking code and thus is not covered by my earlier study. . Again, thanks for your timely review of the parking Study: If you have any questions on this matter you may refer them to me if Mr. Stange is not otherwise available. I'll try to assist you in any way I can. Yours truly, C. V. Brown, P.E. cc Mr. Roger. Stange Mr. Mason Frank • Traffic Engineers CO Transportation Planners JU U 0. CO CO ur J w 0 u. Q' co d`. Z' z�. �- 0, z 01 :0 El;. o�_ =w H U LL, i=- -0 wz UN 0�� z CITY .■ TUKWILA DEPARTMENT OF COMMUNITY DEVELOPMENT TITLE: FAX NUMBER: (206) 431-3665 DATE: FROM: iericarTh 1 COMPANY: es— DEPARTMENT: TITLE: DEPARTMENT: ,PfP.f.,,,f.f.X.X.P,,,,f,PfPXPIPX.,:.:PP:PCPIPCPIPMW.P.MPOP".:P>...0,...X.M.X.f.:PW.M.X*X.X.M...X.DP:P070.1":070.:4110Y,POOP:00.:~054.P.X.PPOMP:POW'APPOPOPPLPIPMOOPPW.44.X.,90P,W~X FAX NO. 603 ea70. c.)0 36 NUMBER OF PAGES TRANSMITTED, INCL. G THIS COVER SHEET: fr.*/ AGAIMV/eRgiavi3VeY iroW•KRAMWMIX+FoMMLIeeifiedVA1/47Vele SENT BY (INITIALS): ov..w fttmor /AP.: IF THIS COMMUNICATION IS NOT CLEARLY RECEIVED, PLEASE CALL: DEPARTMENT OF COMMUNITY DEVELOPMENT 6300 Southcenter Boulevard, Tukwila WA 98188 z Z IXw 2 0 0 0 CO i- w 0 2 r, ±" CI. 1- LI Z 0 zI—. LLI 2 n 0 0) 0 — .0 LIJ -C3 o z tu 17: o 1- z September 26, 1997 Ms. Nora Gierloff City of Tukwila Department of Comunity Development 6300 Southcenter Blvd. Tukwila, WA 98188 i • Parkway SuperCenter Tukwila, Washington Architect's Project No 97111 ear Nora: BENNER STANGE ASSOCIATES ARCHITECTS, P.C. :.•i?TR.f,. 5000 SOUTHWEST MEADOWS ROAD SUITE 430 LAKE OSWEGO OREGON 97035 As requested, enclosed is a check for $ 200.00 for the variance process submitted for the above referenced project Please call me if you have any questions. Thank you for your assistance. Sincerely, BENNER STANGE ASSOCIATES ARCHITECTS, P.C. fZoger . Lange RWScmav enclosure o:/97111/letters/1997/09 -26 Gierloff 503 670 -0234. FAX 670 -0235 bsa @pi- express.com .•�: Christopher Brown Associates 879 Rainier Avenue N.. (Suite A -201 Renton. WA 98055 -1380 (206) 772 -1188 Fax 772 -4321 September 26, 1997 Mr. Roger W. Stange Benner Stange Associates, P.C. z 5000 Southwest Meadows Road, Suite 430 i z' Lake Oswego, OR 97035 it �, JU:. UO: Re: City of Tukwila , loo. J = H CO LL w O J In accordance with your request I am enclosing a co py of the w Q Parkway Supercenter, Parcel 'A' parking analysis with its N o. ' "Conclusions" (page 10) and the attendant recommendation for an I- w ' "Administrative Variance" (page 11). ,z 1-0'. Briefly, considering Parcel 'A' with some 443,382 gsf and with' w ai the code required 4.0 parking stalls per 1,000 gsf the design '2 D; would suggest some 1,774 parking stalls. However, your design 0 CD; shows 1,740 stalls which is a rather minor deviation. ;p F-, al • I I— U U. F=' _ 0, Z: Parkway Supercenter Parking Analysis Dear Mr. Stange: Nonetheless, the purpose of the attached study is to review the parking demands on the basis of both commercial - retail and also restaurant space. Further, in this regard, attention is focused on the typical Saturday peak parking demands since Saturday is the peak day -of- the -week. Likewise, since retail sales and restaurants do not peak at the same time, the study also notes the peak parking for each of these activities by hour -of- the -day for the typical Saturday. Finally, since some of the stores will be used for bulk retail sales (furniture and appliances which has been the historical case in this section of the city) the code required parking for this activity, set out in terms of a range (minimum and maximum likelihood), is also shown. The conclusion is that the amount of parking you have described is more than sufficient for the Parkway Supercenter, Parcel 'A' and a request for a variance is indeed appropriate. C. V. Brown, P.E. cc City of Tukwila encl. Traffic Engineers C4 Transportation Planners ')1..( 2 5 1997 'dry �ifl�t��i�,�� \ "• �. ' : . z 9 -25 -1997 9:31AM FROM BENNER STANGE ASSOC. 503 228 3821 September 25, 1997 Ms. Nora Gierloff City of Tukwila Department of Comunity Development 6300 Southcenter Blvd. Tukwila, WA 98188 Re: Parkway Super Center Tuckwila, Washington • Architect's Project No. 97111 P. 2 BENNER STANGE ASSOCIATES ARCHITECTS, P.C. 5000 SOUTHWEST MEADOWS ROAD SUITE 430 LAKE OSWEGO OREGON 97035 a i--z; rrw: 6 JU: :00, (A W• III =' CO W 0' J. w¢;. =d Iw z. z ~, z w; Dear Nora: 2 °, -. Enclosed is a copy of the parking analysis by Christopher Brown and Associates for the ° . renovated,Parkway SuperCenter project. As we discussed, we request a variance for Area `A' . = w; of the Parkway SuperCenter project from four cars per thousand square feet of retail space to w o; 3.5 car per thousand square feet of retail'space. This is a vast improvement over the current w z; parking ratio' and, as outlined within the Christopher Brown study, meets and exceeds current c.) 1. oITE standards. We would appreciate your response to this variance request as soon as O . possible. Please feel, free to contact me with any questions or concerns. z • . Sincerely, NNER STANGE ASSOCIATES ARCHITECTS, P.C. oger RWS:mav enclosures 0 cc: Mason Frank, MBK Northwest Ltd. Christopher Brown, Christopher Brown and Associates o: \97111 \leter \1997 \09.25 Gierloff SEP 25197 + 11iut:)ti�iVli iu.. 503 670-0234 FAX 670-0235 bsa @pl•express,com Christopher Brown Associates 879 Painier Avenue N., quite A -201 Penton, WA 98055 -1380 (206) 772 -1188 Fax 772 -4321 PARKWAY SUPERCENTER Parking Analysis A Study of Required Parking by Current City Code and Traffic Engineering Practice September 24, 1997 Traffic Engineers 0 Transportation Planners SEP 2 5 1997 r�5o -zn t,f r. .•.t... �-.OrM:ViuN �. ,if PARKWAY SUPERCENTER Parking Analysis A Study of Required Parking by Current City Code and Traffic Engineering Practice TABLE OF CONTENTS Introduction 1. Site Designation, Parcels 'A' and 'B' 2. Purpose 2. Location 2. Proposed Parkway Supercenter 4. Proposed Parcel 'A' Code Required Parking 4. Comment on Code Parking Needs 7. Conclusions 10. Recommendation 11. List of Tables • I Parcel 'A' Proposed Commercial Areas 4. II Parcel 'A' Maximum & Minimum Areas for Parking 6. III Code Required Parking 7. IV Range in Possible Code Parking Shortage 7 V Estimated Peak Parking Demands 8. VI Peak Parking Demands by Hour of Day 9. Appendix Christopher Brown Associates 879 Rainier Avenue N., Suite A -201 Renton. WA 98055 -1380 (206) 772 -1188 ¢•• • = z _2 •O O :(/) 0; ' .J F=" wa:... • ,}-w zI-; • w w: N," • wW = V; ui Zr:' • U N° 017 . • :z PARKWAY SUPERCENTER Parking Analysis A Study of Required Parking by Current City Code and Traffic Engineering Practice Introduction MBK Northwest is contemplating the acquisition and modification of properties located in the southern section of the City of Tukwila's main commercial retail core - Parkway Plaza and the Pavilion Mall. Two significant construction projects will be undertaken which will effect both internal traffic circulation and parking maneuverability. This construction program incorporates the following: 1. The removal of a portion of the front of the main building situated in the center of Parkway Plaza so that the more linear design of the store frontage(s) will enhance pedestrian circulation and, equally if not more importantly, at the same time lead to a reconfiguration of the parking lot so that the main parking areas will primarily contain 90° stalls with aisles oriented on an east -west axis with exceptions being on the periphery 90° stalls. 2. The Pavilion Mall will be replaced by a multi- screen theater and two new restaurants. Both of these modifications will include the addition of free standing restaurants and new retail sales pads. In particular, the site immediately in front of the theatre will have two restaurants (on two separate but proximate pads) while the site in front of the reconfigured Parkway Plaza will include one new restaurant pad and a new retail sales pad. -1- Christopher Brown Associates 879 Rainier Avenue N., Suite A -201 Renton. WA 98055 -1380 (206) 772 -1188 • •z _ • :.mow oc 2 .6 n' U O No; N W_. co: LL W o: J. • co • •=C! I-W z,- • .0 c. •,O N.. • ' W W: - O. ..Z. N. o s • z Site Designation, Parcels 'A' and 'B' For the purposes of this parking analysis the site containing the Parkway Plaza is called Parcel 'A' while the southerly site for the 12- screen cineplex and the two new restaurants is called Parcel 'B'. The designation of two distinct "parcels" is not meant to suggest or imply that either one operates in an isolated fashion from a traffic circulation point of view or that parking on one site precludes pedestrian access to the other. Indeed, all- weather pedestrian ways are to be constructed in order to facilitate internal pedestrian movements. Purpose The purpose of this study is to evaluate future parking demand associated with Parcel 'A' since the reconfigured building and the two new pads, when completed, tends to produce a site that does not quite meet the recently adopted (May 5, 1997) revised city parking code. In this regard it may be noted that the use of "cooperative parking" or what is sometimes called "shared parking" has an historical basis that goes back to the days of initial construction at the Parkway Plaza. Accordingly, in the event of parking deficiencies that may arise from any new code based analysis, this concept may carry forward. The essence of this study is to ensure that parking will be adequate from a customer base as well as from a city parking code base. Location The location of the Parkway Supercenter is the northeast quadrant of S. 180th Street and Southcenter Parkway in the southern part of the main retail shopping sector of the City of Tukwila, King County, Washington. It is shown on Figure 1, the Vicinity Map. -2- Christopher Brown a Associates 879 Rainier Avenue N.. Suite A -201 Renton. WA 98055 -1380 (206) 772 -1188 z z ,w 6 UO cnw; W= H N u . ;. w O, J: u1. Q = C7 f- w zF� I- O. z ut � o O '0 w w`• U. Z ui p O H z 1 :n :'i r• To I 1 1 S s 111141 MOT" Si ES ISO T" ST ST S �\ St.,, a I y y ,1 • \\ ct 1 PARK .\ n It ' \ �igLIrr' .S r Pa • `. \ �\ ` `t, NOR /MERPO-, G4 • MM. ^/I ILMI $ t 3TL `ls tam — 168 TN ST 1 °" s Virg I,N11 tttI4 S 170m 1ST G 3W 1 24 • I I.: 11 tai: • it is °agarres 11 ..1 Race ( • • iITrac._I II • CHRIST. MMSTN IRITNlt[T /K 251 R COP •PAT! e ....... ST......- • MINKt.ER at:O i 1 i. CC 76"/ ; sr a f iio•"e.ad rP • wy 9p< s..?•:178TN t 4� S 177111 i 10 13 Ip sr t T2JL.. 0. 4 a 1S FIGURE 1 -3- Vicinity Map ST 11 ^, �• s MHO ..ST KFNT., 112 1 • •. . lrTw �r Christopher Brown i Associates 879 Rainier Avenue N.. Suite A -201 Renton. WA 98055 -1380 (206) 772 -1188 Proposed Parkway Supercenter Figure 2, in addition to describing the location of the main parking areas for both the shops and the theater also depicts the style of parking which is can be described, in general, as 90° angle parking served by 2 -way aisles. Pedestrian corridors through the main parking areas are also shown linking the shops with Southcenter Parkway. In general they are located in front of the proposed "Old Navy" store, "Comp USA ", "Babies 'R' Us ", and the cineplex theater, the latter ending near the row of parking on the margin of Southcenter Parkway. The current design of the Parkway Supercenter (as of September 22, 1997) includes the following building scale and associated parking supply. TABLE I Parcel 'A' Proposed Commercial Areas Total Retail Sales (gross space) Total Restaurant (gross space) Total Commercial (gross space) Total Parking Supply Proposed Parcel 'A' Code Required Parking 413,963 gsf 29,419 qsf 443,382 gsf 1,740 stalls On May 5, 1997 the City of Tukwila adopted Ordinance 1795, a new parking code. This sets out the appropriate parking standards to be used for this site along with review processes for variances from the new standards. Briefly, parking to be applied to this site is at the rate of: -4- 4 stalls per 1,000 square feet for shops. 1 stall for each 100 square feet of usable area. 2.5 stalls per 1,000 square feet for bulk retail. Christopher Brown a Associates 879 Rainier Avenue N.. Suite A -201 Renton. WA 98055 -1380 (206) 772 -1188 ' ....._ia.;I sow °OH fM .0114++H+Ha FIGURE 2 —5_ W 0 CC a OIIf4NHOHffl '' aQIIHIM HHn mn-uiii 4#N4i0i14N101N� - '�fll�jiilfflftHHIOIII�#hj1[� \1 `{ 41jlTIi11111UIfTf11r1i ,�65's'M55'#45 1011OIIIHIOlHHI01� =1:. , .$ •�RHHO 4I1014100IHNI 11! 0 uinun— iiA 4+110111N1060 ' nrv,ni, 4,1H 01i311l01NHi0 -'nt'trt .0#00H40I0IN14i0 B��lf/,94I + +4HHI +HIH +4HH +I0 ���] t— +�uuutrt�uut 14-11 9 4IH10IIH+HHNNIO amm.nnr .nrmrrnllnfirrtr o In 40100 OINIH01NN10.OHNHNNG �OIN4H01NNI0144H10 41119 411101O1HHOfHNIO 11110_ cllottttt(J1ttuto a = _°IT1TTTTBr11.TNrtTRTa a(immaunnunn u01N44HOIHHI0111H10 °0I44N10i4#110 +4f0 II _ °0111{H101144141110 111110011fifflillifi = °(Itutmnuuufluntg m(IunuqununttlQ � j _ �jIIIWIW( �IIIIIIIIIIInIIIIIIIIIf�11111W1� , z Wiz: JU 00: (/) o W -J ., LQ —(1) DO F.w Z= W U� 'O co. :CI H wW LL Z w =, o'' Z Considering the associated parking for Parcel 'A' based on gross building areas, with no reductions for unusable areas such as mechanical rooms and rest rooms, and assuming some continued "bulk retail sales" as now found in Parkway Plaza, the following features can be considered. First, of the major tenants there are two (2) whose entire stock can be considered well within the bulk retail sales classification. These are The Bon (40,240 gsf) and Krause's Sofa Factory (21,200 gsf). In addition, Circuit City (32,420 gsf) has about half of its store (16,210 gsf) set aside for appliances. Consequently, at a minimum some 77,650 gsf is associated with bulk retail sales. Second, while the attached Figure 2 shows several vacant stores the current stores now using these spaces, such as the Oak Gallery, Bedroom Superstore (Futons), Dining Interiors, Furniture Mart, Bel -Red Furniture and Sleep Country are all, likewise, bulk retail sales facilities. This grouping does not include Evans Music which sells pianos, certainly a bulk commodity. Leaving out Evans Music, for example, perhaps as much as 20,000 additional gsf can be added to the bulk retail sales group. Consequently, the following range of deductions may be applied. Of course, this would be in keeping with the historical nature of this shopping center where furniture sales have been a rather significant sector. Considering the above two potential kinds of tenants, then, the bulk retail sales can range from a minimum of 77,675 gsf as shown on the current site plan to a maximum of (20,000 plus 77,675) 97,675 gsf, an appropriate upper range of bulk retail space that should be deemed appropriate in view of the historical record. With this range of bulk retail sales, the requisite code required parking can be found. This is shown in Table II. TABLE II Parcel 'A' Maximum & Minimum Areas for Parking Needs Land Use Maximum Retail Sales (General) 336,288 Retail Sales (Bulk) 77,675 Restaurants 29,419 -6- : .... • Minimum 316,288 gsf 97,675 gsf 29,419 gsf Christopher Brown a Associated 879 Rainier Avenue N.. Suite A -201 Renton, WA 98055 -1380 (206) 772 -1188 z • H z: w UO No W I; J I- w O' g u_¢ N O I- w. z �o z 2 (° LI w w; iii z. UN F=1- z TABLE III Code Required Parking Retail Sales (General) 1,345 stalls Retail Sales (Bulk) 194 stalls Restaurants 294 stalls 1,265 stalls 244 stalls 294 stalls Total Code Parking Needs 1,833 stalls 1,803 stalls Depending on the amount of bulk retail sales ultimately leased in the new shopping center naturally leads to a range in the code required parking per the new ordinance. Likewise, such a range naturally leads to a range in the potential parking shortfall. This is to be expected considering the original parking design for this site when first configured as the Parkway Plaza some years ago. The possible range in parking shortages is shown in Table IV. Range in Land Use TABLE IV Possible Code Parking Shortage Maximum Parking Total Code Parking Needs 1,833 Parking Supply, Parcel 'A', (1,740) Possible Parking Deficiency 93 Deficiency, as a percent of Comment on Code Parking Needs Minimum Parking 1,803 stalls (1,740 stalls) 63 stalls code 5.1 % 3.5 % From the above analysis based on a range of possible bulk retail sales the projected shortage in code required parking appears to be minimal. -7- Christopher Brown Associates 879 Rainier Avenue N.. Suite A -201 Renton, WA 98055 -1380 (206) 772 -1188 • .z • HZ� uj w J U'. moo` • w X, • • W o IL ct. • J 2 z �. z . tu le :O N. W W: =t) u. Z ui 0 ..z Nonetheless, to test whether or not the proposed parking supply in Parcel 'A' is in conformance with observed parking needs as defined by the Institute of Transportation Engineers (ITE) the publication, Parking Generation (2nd Edition, (1987) of ITE may be useful. In addition, since ITE has quantified the maximum parking needs for both an average weekday and for a Saturday, both of these periods can be addressed. In particular, since Saturdays tend to be the highest use days in a shopping center, a Saturday can serve as a useful comparison against code required parking. z • D JU U O ' vow. In Parcel 'A' there are two (2) ITE Land Use Codes (LUC) of -1 ' interest. The first is LUC 820 -828 which applies to the cnu-; 413,963 gsf of commercial retail sales. The second is ITE w O Land Use Code 835 which applicable to the typical Family g!5 Restaurant. Note that the latter is a higher parking u.Q generator than a Ouality Restaurant, found under Land Use Code N a. 831, and thus will give a worst case. Indeed, it has a w: suitable margin of error which is on the high demand side. z The weekday and Saturday parking demands are noted below in 1-0 V. � o. U ,O N` w • W Estimated Peak Parking Demands u0; z: Land Use Weekday Saturday vcn; 0 TABLE V Retail Sales (LUC 820 -828) 1,252 stalls 1,385 stalls Restaurants (LUC 835) 279 stalls 219 stalls * Maximum Parking Demand 1,531 stalls 1,604 stalls * based on the maximum parking rate for this LUC Parking Supply Maximum Parking Demand Apparent Surplus Parking 1,740 stalls 1,740 stalls 1,531 stalls 1,604 stalls 209 stalls 136 stalls Based upon the combined maximum demand for peak parking (which assumes the peak hours of restaurants and commercial retail - sales are coincident, as measured by traffic engineering -8- :!� � . Christopher Brown g Associates 879 Rainier Avenue N.. Suite A -201 Renton. WA 98055 -1380 (206) 772 -1188 z standards for the worst case which will be on a Saturday when 1,604 stalls are required, a small surplus of 136 stalls or some 7.8 percent will exist. Accordingly, it may be concluded on the basis of current ITE parking demand standards that an adequate supply of parking will be available for Parcel 'A' of the Parkway Supercenter. Of particular note, this is also based on the worst case assumptions regarding the restaurant sites. In addition, as shown in a previous study for the Cucina Cucina Restaurant in this same shopping plaza, the peak parking demand for the commercial retail sales and the restaurants is not coincident, either. Thus, the peak parking needs for the shops occurs in the 2:00 to 3:00 interval while restaurants will be at a maximum later in the day peaking from 7:00 to 9:00 p.m. The disparate peaking in the two kinds of enterprises leads to an appropriate consideration of shared parking. For a Saturday, the busiest day of the week at the center, the following forecast parking demands may be a useful reference. -9- TABLE VI Peak Parking Demands by Hour of the Day Saturday Retail Restaurants Total Hour of Day Demand 10:00 609 16 626 11:00 1025 22 1047 Noon 1163 66 1229 1:00 1302 99 1401 2:00 1385 99 1484 3:00 1385 99 1484 4:00 1274 99 1373 5:00 1053 131 1184 6:00 886 197 1084 7:00 859 208 1067 8:00 776 219 995 9:00 443 219 662 * The above distribution of parking by time -of -day for a Saturday is based on the Urban Land Institute study entitled The Dimensions of Parking (1993), Table 5 -6, Shared Parking Ratios; Hourly Parking Demand Ratios - Default Values. Christopher Brown Associates 879 Rainier Avenue N.. Suite A -201 Renton, WA 98055 -1380 (206) 772 -1188 z w JV •UO: u) • W =; CO LL; uj g mom: al z� I-O` Z W.• N: Wu � U LL ~ - O; •u, U O z 1 With a parking supply of 1,740 stalls there is a comfortable margin of safety at the time of peak shopping center parking demand which takes place in the early afternoon. In the 2 :00 z to 3:00 o'clock interval, on a Saturday, the surplus parkin g will run to about 256 stalls or some 14.7 percent of the = w total. Again this surplus, based on shared parking, supports M. ?; the granting of a variance from the code mandated supply. U; 0 0. .V)W J 1, CO O. w The entire retail sales sector of the Parkway Supercenter takes N place in an area called Parcel 'A'. The building areas total W 443,382 gsf including 29,419 gsf for restaurants. Some 1,740 z parking stalls are proposed on parcel 'A'. H 0 O: Z I- Conclusions The recently adopted parking code for the City of Tukwila sets forth standard parking requirements and also allows a modest deduction for stores that are engaged in bulk retail sales. Typically these are related to furniture and appliances. Considering a possible range in bulk retail sales, the range in code required parking varies from 1,803 to 1,833 stalls. The deficit in parking, depending on the range used, extends from 63 to 93 stalls or about 3.5 to 5.1 percent of the total parking supply. However, contrasting the code required parking against the theoretical maximum parking demands, as determined from published ITE criteria, shows that on a practical basis there will be a surplus amount of parking. The worst day of the week is a Saturday and on a Saturday the ITE recommended parking is 1,604 stalls. This indicates that a surplus will exist. Next, the Urban Land Institute has documented the variation in parking demand by hour -of- the -day for both retail sales as well as restaurants. The peak parking demand for retail stores on a Saturday is from 2:00 to 3:00 in the afternoon. Conversely, for a restaurant it is after 7:00 p.m. Consequently, the concept of shared parking comes into play and can be used to modify the respective peak demands for these two diverse kinds of enterprises. -10- Christopher Brown g Associates 879 Rainier Avenue N.. Suite A -201 Renton, WA 98055 -1380 (206) 772 -1188 :... w .2 n p' 0 N'. 'w 1- Z, ui • 101— .z Based on the shared parking concept, the maximum demand for parking in Parcel A' will be from 2 :00 to 3:00 in the afternoon and amount to some 1,484 stalls. This is about 85 percent of the code mandated parking. Given the surplus parking in Parcel 'A' as shown by ITE methods and further amplified using the ULI demands by hour -of- the -day, measured in the basic terms of supply versus demand, a request for a variance in code required parking should be made. There is little reason to believe that the proposed parking supply will be inadequate. Recommendation A request for an Administrative Variance from Parking Standards should be made in accordance with City of Tukwila Municipal Code (TMC) 18.56.140, processed as a Type 2 decision pursuant to TMC 18.108.020 since the deviation from the adopted standard is less than 10 percent. Christopher Brown Associates 879 Rainier Avenue N.. Suite A -201 Renton, WA 98055 -1380 (206) 772 -1188 or • • .w =, • • • uJo � w z moo' :z ;0-`: • o 'F - �` o; 0 PARKWAY SUPERCENTER Parking Analysis A Study of Required Parking by Current City Code and Table of Contents Traffic Engineering Practice APPENDIX 1. Extract from City of Tukwila Parking Code 2. ITE Land Use Code 820 -828, Weekday Peak Parking, Shopping Center 3. ITE Land Use Code 820 -828, Saturday Peak Parking Shopping Center 4. ITE Land Use Code 835, Weekday Peak Parking Family Restaurant 5. ITE Land Use Code 835, Saturday Peak Parking Family Restaurant ULI Shared Parking Ratios: Table 5 -5, Monthly Variation Table 5 -6, Hourly Variation • • gg4 Places of public asser•'"Av, in. cluding auditoriums, .ibition halls, community clubs, com• munity centers , and private clubs. The Director shall determine the num. ber of required parking spaces, with a minimum of t space for every 100 square•feet of assembly area. To ensure parking adequacy for each proposal, the Director may consider the following: a. A parking study or documentation paid tor by the applicant and admin. istered by the City regarding the ac• tuat parking demand for the pro. posed use or b. Evidence in available planning and technical studies relating to the pro. • osed use. 1 e per 50 parking stalls, witn a minimum of 2 spaces. Post offices 3 for each 1,000 square feet of usable floor area 1 space per 50 parking stalls, with a minimum of 2 spaces. Public facilities, including librar. ies, police and fire stations Shall be determined by the Planning Commission 1 space per 50 parking stalls, with a.minimum of 2 spaces. 1 space per 50 parking stalls, with a minimum of 2 spaces. Restaurant I for each 100 square feet of usable floor area Restaurant, Fast food 1 for each 50 square feet of usable floor area. Fifty percent of any outdoor seat. Ing area will be added to the usable floor area for parking requirement cal. culatlons. 1 space per 50 parking stalls, with a minimum of 2 spaces. Retail Sales, Bulk 2.5 for each 1,000 square feet of. us. able floor area 1 space per 50 parking stalls, with a minimum of 2 spaces. Retail sales, General 4 for each 1,000 square feet of usable floor areal! located within the TUC or TVS zoning districts; 2.5 for each 1,000 square feet of usable floor area If located In any other zoning district. 1 space per 50 parking stalls, with a minimum of 2 spaces. 1 space per classroom Elementary and Junior high 1.5 for each staff member schools Shopping center (mall), planned, d per usable floor area size, as listed below 500,000 sq. ft. 5 for every 1,000 sq. ft. 1 space per 50 parking stalls, or larger with a minimum of 2 spaces. 25,000 — 499,999 sq. ft. 4 for every 1,000 sq. ft. I space per 50 parking stalls, with a minimum of 2 spaces. Taverns 1 for every 4 persons based on occu• .anc toad. 1 space per S0 parking stalls, with a minimum of 2 spaces. Theaters 1 for every 4 fixed seats. if seats are not fixed, 1 per 3 seats, with concur• rence of Fire Chief, consistent with maximum allowed occupancy t space per 100 seats, with a minimum of 2 spaces, Warehousing 1 for every 2,000 square feet of usable floor area 1 space per 50 parking stalls, with a minimum of 2 spaces. S'd 18.56.060 Loading space requirements. Off•street space for standing, loading and unloading services shall be provided in such a manner as not to obstruct freedom of traffic movement on streets or alleys. For all office, commercial, and industrial uses, each loading space shall consist of at least a ten•foot by 30.foot loading space with 14•foot height clearance for small trucks such as pickup trucks, or a 1 Z•faot by 65•foat loading space with 14•foot height clearance for large trucks, including tractor• trailer large spaces. The prescribed number of spaces required are as follows: Loading Space Requirements Square Feet of Grass Floor Area (Except Rasement Area) Number or Spaces OMce Buildings, Hotels, Hospitals, and Instltutlons 1 3,000 to 100,000 2 100,000 to 335,000 3 335,000 to 625,000 4 625,000 to 945,000 5 945,000 to 1,300,000 6 . 1,300,000 to 1,695,000 _ 7 1495,000 to 2,130,000 6 2,130.000 to 2,605,000 9 2,605,000 to 3,120,000 10 3,1 0,000 to 3,675,000 ZONL'PARK,DOC Sl7197 Md /Q3a d1IMNfll WdTE : VO 2.6:i Zz d3S ' • .:: SHOPPING CENTER (820 -828) Peak Parking Spaces Occupied vs: 1,000 GROSS SQUARE FEET LEASABLE AREA On a: WEEKDAY PARKING GENERATION RATES Average Range of Standard Number of Rate Rates Deviation Studies Average 1,000 Square Feet GLA 3.23 1.02 -6.17 1.20 141 635 DATA PLOT AND EQUATION 10,000 9,000 - w • 8,000 - U O 7,000 - N o 6,000 - a N 5,000 - z S2 a 4,000 - 3,000 - w °- 2,000.- d 1,000 - 0 1 I 1 I 1 1 1 I I 1 1 1 1 1 1 I 0 200 400 600 800 1,000 1,200 1,400 1,600 1,800 X = 1000 GROSS SQUARE FEET LEASABLE AREA ❑ ACTUAL DATA POINTS FITTED CURVE Fitted Curve Equation: Ln(P) = 1.173 Ln(X) + 0.064 R2 = 0.939 Parking Generation, August 1987 /Institute of Transportation Engineers 126 . ■ • SHOPPING CENTER (820 -828) Peak Parking Spaces Occupied vs: 1,000 GROSS SQUARE FEET LEASABLE AREA On a: SATURDAY PARKING GENERATION RATES Average Range of Standard Number of Rate Rates Deviation Studies Average 1,000 Square Feet GLA 3.97 1.11 -6.06 1.13 178 838 DATA PLOT AND EQUATION P = PEAK PARKING SPACES OCCUPIED 10,000 9,000 - 8,000 - 7,000 - 6,000 - 5,000 - 4,000 - 3,000 - 2,000 - 1,000 - 0 1 1 1 1 I 1 1 I 1 1 1 I 1 1 r 1 I 200 400 600 800 1,000 1,200 1,400 1,600 1,800 X = 1000 GROSS SQUARE FEET LEASABLE AREA ❑ ACTUAL DATA POINTS FITTED CURVE Fitted Curve Equation: Ln(P) = 1.261 Ln(X) - 0.365 R2 = 0.948 Parking Generation, August 1987 /Institute of Transportation Engineers 127 , '' : z 6 R JU W W W =' JF- ` W O' u. ¢.. � d, z� I- O' Z I- D o co, 0 F-: W W; • U` O' ti•z U N H I- O z. FAMILY RESTAURANT (835) Peak Parking Spaces Occupied vs: 1,000 GROSS SQUARE FEET LEASABLE AREA On a: WEEKDAY PARKING GENERATION RATES Average Range of Standard Number of Rate Rates Deviation Studies Average 1,000 GSF Leasable Area 9.08 5.67 -13.50 2.07 11 6 DATA PLOT AND EQUATION 100 w 90- 9 v 80- U 0 cr) 70 - w U a 60 - tn C7 50 - ac a 40 Q a 30 0 u 20- 10 2 1 1 1 1 1 1 1 1 4 6 8 10 X = 1000 GROSS SQUARE FEET LEASABLE AREA 0 ACTUAL DATA POINTS FITTED CURVE Fitted Curve Equation: P = 9.54(X) -- 2.0 R2 = 0.928 Parking Generation, August 1987 /Institute of Transportation Engineers 138 .`' tr ; • oC W, 6 �o O'. • •w o :I.. LL < • .u)a• • _ 1- • 1-0:. �z l- N. • • w W: • L-6 F' o: 111 Z FA.t4ILY RESTAURANT (8:35) Peak Parking Spaces Occupied vs: 1,000 GROSS SQUARE FEET LEASABLE AREA On a: SATURDAY PARKING. GENERATION RATES Average Range of Standard Number of Rate Rates Deviation Studies 6.96 6.45 -7.46 Average 1,000 GSF Leasable Area 2 10 CAUTION —USE CAREFULLY —SMALL SAMPLE SIZE. NO PLOT OR EQUATION AVAILABLE INSUFFICIENT DATA* Parking Generation, August 1987 /Institute of Transportation Engineers 139 :••,•••• -..... • 5 -5 Shared Parking Ratios: Monthly Variation in Peak Parking Demand Ratios - Default Values (Percent of Peak Month) Hotel Rooms Hotel Hotel Month Office Retail Restaurant Cinema Residential Weekday Saturday Conference Convention January 100° 65 °`a 50% 90°'0 100% 900'0 650.'o I00% 20% February 100 65 75 70 100 90 70 100 40 March 100 70 90 50 100 95 80 100 80 April 100 70 90 70 100 95 85 100 80 May 100 70 95 70 100 95 85 100 100 June 100 75 100 100 100 100 90 100 100 July 100 75 100 100 100 100 100 100 50 August 100 75 85 70 100 100 100 100 50 September 100 75 80 80 100 95 90 100 70 October 100 75 80 70 100 95 90 100 70 November 100 . 80 80 50 100 85 80 100 40 December 100 100 90 50 100 85 65 100 20 Source: ULI, Shared Parking (1983). 5-6 Shared Parking Ratios: Hourly Parking Demand Ratios - Default Values Office Retail Restaurant Spaces per 1,000 Spaces per 1,000 Spaces per 1,000 Cinema Square Feet of GLA Square Feet of GLA Square Feet of GLA Spaces per Seat Hour of Day Weekday Saturday Weekday Saturday3 Saturdays Weekday Saturday Weekday Saturday 6:00 a.m. 0.1 - - - - 7:00 a.m. 0.6 0.1 0.3 0.1 0.2 0.5 0.5 8:00 a.m. 1.9 0.3 0.7 0.4 0.5 1.0 0.5 9:00 a.m. 2.3 0.4 ' 1.6 1.2 1.5 2.0 1.0 10:00 a.m. 3.0 0.4 2.6 1.8 2.2 4.0 1.5 11:00 a.m. 3.0 0.5 3.3' 2.9 3.7 6.0 2.0 - 12:00 noon 2.7 0.5 3.7 3.4 4.2 10.0 6.0 0.10 0.10 1:00 p.m. 2.7 0.4 3.8 • 3.8 4.7 14.0 9.0 0.15 0.20 2:00 p.m. 2.9 0.3 3.7 4.0 5.0 12.0 9.0 0.15 0.20 3:00 p.m. 2.3 0.2 3.6 • • 4.0 5.0 12.0 9.0 0.15 0.20 4:00 p.m. 2.3 0.2 3.3 • 3.6 4.6 10.0 9.0 0.15 0.20 5:00 p.m. 1.4 0.1 ,3.0 3.0 3.8 14.0 12.0 0.15 0.20 6:00 p.m. 0.7 0.1 3.1 2.6 3.2 18.0 18.0 0.20 0.25 7:00 p.m. 0.2 0.1 3.4 2.4 3.1 20.0 19.0 0.20 0.25 8:00 p.m. 0.2 0.1 3.3 2.2 2.8 20.0 20.0 0.25 0.30 9:00 p.m. 0.1 - 2.3 1.6 2.1 20.0 20.0 0.25 0.30 10:00 p.m. 0.1 1.2 1.5 1.9 18.0 19.0 0.25 0.30 11:00 p.m. - 0.5 0.5 0.5 14.0 17.0 0.20 - 0.25 12:00 midnight - - 10.0 14.0 0.15 0.20 Peak parking ratio 3.0 0.5 3.8 4.0 5.0 20.0 20.0 0.25 0.30 Percent auto usage 100 100 100 100 100 100 100 100 100 Average persons/auto 1.2 1.2 1.8 1.8 1.8 2.0 2.0 2.0 2.0 'Represents nonguest parking demand, assuming 50 percent of restaurant patrons and 100 percent of conference and conven- tion attendees are nonguests. Conference and convention demands indicated are upper bounds, which are rarely achieved. 2At one auto per dwelling unit. 34 The Dimensions of Parking ' Z H W '. J U. U0 uJ W= W 2 g J. to ▪ d Z �. Z f- W W, H U. rz 0' .Z U D. o Z