Loading...
HomeMy WebLinkAboutPermit L05-080 - LISTFJELD CHRIS / RIVERTON UNITED METHODIST CHURCH - WIRELESS TELECOMMUNICATIONS CONDITIONAL USET- MOBILE 3118 S 140 ST L05 -080 RELATED: E05 -021 City Of Tukwila II City of Tukwila Department of Community Development Steve Lancaster, Director To: Mr. Chris Listfjeld T- Mobile USA 19807 North Creek Parkway N Bothell, WA 98011 cc. King County Assessor's Office Barbara Bader Mary Cootz NOTICE OF DECISION September 29, 2006 SEPA DETERMINATION: SEPA DNS issued 8/11/2006 COMPREHENSIVE PLAN/ ZONING: Low Density Residential (LDR) 0 At the September 28, 2006 public hearing, the Planning Commission approved the applicant's Conditional Use Permit (CUP) application. The Planning Commission approved the applicant's request for a Conditional Use Permit (CUP) to install wireless communication antennas within a shroud located on a cross at the Riverton Methodist Church. The Planning Commission approved the application with the following condition: 1. The antenna shroud shall match the color of the cross. PROJECT BACKGROUND FILE NUMBER: L05 -080 APPLICANT: Chris Listfjeld OWNER: Riverton United Methodist Church REQUEST: Installation of wireless antennas within a shroud. The shroud will be located on a Christian Cross LOCATION: 3118 S. 140 Street ASSOCIATED PERMITS: Building Permit Property owners affected by this decision may request a change in valuation for property tax purposes notwithstanding any program of revaluation. Page 1 09/29/2006 Steven M. Mullet, Mayor 6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone: 206 - 431 -3670 • Fax: 206 - 431 -3665 APPEALS • 1 The period for administrative appeals is 14 -days, starting from the issuance of this Notice of Decision. The administrative body hearing the appeal is the City Council. All appeal materials shall be submitted to the Department of Community Development. Appeal materials shall contain: 1. The name of the appealing party, 2. The address and phone number of the appealing party, and if the appealing party is a corporation, association or other group, the address and phone number of a contact person authorized to received notices on the appealing party's behalf, and 3. A statement identifying the decision being appealed and the alleged errors in that decision. The Notice of Appeal shall state specific errors of fact or errors in application of the law in the decision being appealed, the harm suffered or anticipated by the appellant, and the relief sought. The scope of an appeal shall be limited to matters or issues raised in the Notice of Appeal. 4. An appeal fee of $100. The public notice sign must be removed from the site by the applicant after the appeal period has expired, unless an appeal is filed with the City. Project materials including the application, any staff reports, and other studies related to the permit(s) are available for inspection at the Tukwila Dept. of Community Development; 6300 Southcenter Blvd.; Suite .00; Tukwila, WA; from Monday through Friday, between 8:30 AM to 5:00 The p •. planner is Brandon J. Miles, who may be contacted at (206) 431 -3684 or by - . ' at b ci.tukwila.wa.us. Brandon J. Miles Assistant Planner City of Tukwila City Of Tukwila Page 2 09/29/2006 Dept. Of Community Development City of Tukwila AFFIDAVIT OF DISTRIBUTION - 1, S uset. HEREBY DECLARE THAT: Notice of Public Hearing Determination of Non= Significance Project Name: 0/115i) Le Notice of Public Meeting, , , Project Number: L -C).c- 78 Mitigated Determination of Non- Significance Mailer's Signature: t . Board of Adjustment Agenda Pkt Person requesting mailing: Carill Determination of Significance & Scoping Notice Board of Appeals Agenda Pkt Notice of Action , Planning Commission Agenda Pkt Official Notice Short Subdivision Agenda Notice of Application . Shoreline Mgmt Permit Notice of Application for Shoreline Mgmt Permit _ FAX To Seattle Times Classifieds Mail: Gail Muller Classifieds PO Box 70 - Seattle WA 98111 1 V Other ler:4:Sioq Was mailed to each of the addresses listed on this 2 4 day of year 20 P:GINAWYNETTA/FORMS /AFFIDAVIT -MAIL 08/29/003:31 PM Project Name: 0/115i) Le Project Number: L -C).c- 78 Mailer's Signature: t . -' Person requesting mailing: Carill Was mailed to each of the addresses listed on this 2 4 day of year 20 P:GINAWYNETTA/FORMS /AFFIDAVIT -MAIL 08/29/003:31 PM Dept. Of Community Development City of Tukwila AFFIDAVIT OF DISTRIBUTION I , HEREBY DECLARE THAT: • / Notice of Public Hearing Determination of Non-Significance Notice of.Public.Meeting. Mitigated Determination of Non- Signi fi cance •Q� Board of Adjustment Agenda Pkt Project Number: Ls Determination of Significance & Scoping Notice Board of Appeals Agenda Pkt M .), Notice of Action • Person requesting mailing: Planning Commission Agenda Pkt 11 /040l -- Official Notice Short Subdivision Agenda Notice of Application _ Shoreline Mgmt Permit ' Notice of Application for Shoreline Mgmt Permit __ __ FAX To Seattle Times Classifieds Mail: Gail Muller Classifieds PO Box 70 - Seattle WA 98111 Other • . Was mailed to each of the addresses listed on this "ay of year 20Dq.Q P:GINAWYNETTA/FORMS/AFFiDAVIT -MAIL 08/29/003:31 PM in the Project Name: T � V `� got - t •Q� • Project Number: Ls 000 Mailer's Signature: M .), '' - Person requesting mailing: 11 /040l -- Was mailed to each of the addresses listed on this "ay of year 20Dq.Q P:GINAWYNETTA/FORMS/AFFiDAVIT -MAIL 08/29/003:31 PM in the • City of Tukwila NOTICE OF APPLICATION DATED June 7, 2006 OTHER REQUIRED PERMITS: Building Permit, City of Tukwila DCD Steven M. Mullet, Mayor Department of Community Development Steve Lancaster, Director The following applications have been submitted to the City of Tukwila Department of Community Development for review and decision. APPLICANT: T- Mobile Wireless AGENT: Chris Listfjeld LOCATION: 3118 S. 140 Street. OWNER OF THE PROPERTY: Riverton Park United Methodist Church FILE NUMBER: Conditional Use Permit, L05 -080 Environmental Review, E05 -021 PROPOSAL: T- Mobile has submitted a Conditional Use Permit application and State Environmental Protection Review application to the Department of Community Development to install and operate a wireless communication monopole at the Riverton Park Methodist Church. A fifty foot tall steel pole will be used to support the antenna equipment. The associated ground equipment will be located along the eastside of the existing church building. A six -foot tall chain -link fence with privacy slats will be used to secure the ground equipment. OTHER PERMITS THAT MAY BE REQUIRED: Electrical Permits, Washington State Department of Labor and Industries These files can be reviewed at the Department of Community Development, 6300 Southcenter Blvd., #100, Tukwila, WA. Please call (206) 431 -3670 to ensure that the file(s) will be available. 6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone: 206 - 431 -3670 • Fax: 206 - 431 -3665 You can submit comments on this application. You must submit your comments regarding the Conditional Use Permit in writing to the Department of Community Development by 5:00 p.m. on June 21, 2006. This project will also go before the Planning Commission for a public hearing and you will receive a public notice informing you of the date and time. If you have questions about this proposal contact Brandon J. Miles, Planner -in- charge of this project at (206) 431 -3684 or by email at bmiles @ci.tukwila.wa.us. Anyone who submits written comments will become parties of record and will be notified of any decision on this project. Please send comments to: City of Tukwila Planning Attn: Brandon J. Miles 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 OPPORTUNITY FOR PUBLIC COMMENT APPEALS You may request a copy of any decision by the Planning Commission on a project or obtain information on your appeal rights by contacting the Department of Community Development at (206)- 431 -3670. A decision from the Planning Commission may be appealed to the City Council. The Department will provide you with information on appeal if you are interested. DATE OF APPLICATION: December 29, 2006 NOTICE OF COMPLETE APPLICATION: May 30, 2006 NOTICE OF APPLICATION POSTED: June 7, 2006 Determina Notice Notice of Actin Board of Adjustment Agenda Pkt Board of Appeals Agenda Pkt Planning Commission Agenda Pkt HEREBY DECLARE THAT: Notice of Public Hearing Notice of Public Meeting Short Subdivision Agenda Shoreline Mgmt Permit FAX To Seattle Times Classifieds Mail: Gail Muller Classifieds PO Box 70 - Seattle WA 98111 Dept. Of Community Develo City of Tukwila AFFIDAVIT OF DISTRI Determinat Mitigated Notice of Permit Other Was mailed to each of the addresses listed on this year 20 Oct P:GINAWYNETTA/FORMS /AFFIDAVIT -MAIL 08/29/003:31 PM Project Name: Project Number: Mailer's Signature: ?A,{,,4410 Person requesting mailing: Yc,/ May 30, 2006 Mr. Chris Listfjeld T- Mobile USA 19807 North Creek Parkway N Bothell, WA 98011 0 city of Tukwila • Department of Community Development Steve Lancaster, Director NOTICE OF COMPLETE APPLICATION Re: Notice of complete application; Conditional Use Permit 3118 S. 140` Street T- Mobile Dear Mr. Listfjeld: The Department of Community Development received your additional information for your conditional use permit on March 31, 2006 for the installation of a wireless communication facility at 3118 S. 140 Street. Based on a review of your application for submittal requirements for Conditional Use Permit, your application is deemed complete as of May 30, 2006. A notice of land use application will be distributed on June 10, 2006. The next step is for you to install the notice board on the site by June 10, 2006. You received information on how to install the sign with your application packet. If you need another set of those instructions, you may obtain them at the Department of Community Development (DCD). Also, you must obtain a laminated copy of the Notice of Application to post on the board. This notice is also available at DCD. After installing the sign with the laminated notice, you need to return the signed Affidavit of Posting to our office. This determination of complete application does not preclude the ability of the City to require that you submit additional plans or information, if such information is necessary to ensure the project meets the substantive requirements of the City or to complete the review process. The application has been routed to other City Departments for their review and comment. In the coming weeks you will receive a formal comment letter regarding the CUP application. If you have any questions, you can contact me at (206) 431 -3684 or by email at bmiles@ci.tukwila.wa.us. Sincerely, Brandon J. Miles Assistant Planner cc. File (L05 -080 and E05 -021) Steven M. Mullet, Mayor 6300 Southcenter Boulevard. Suite #100 • Tukwila. Washington 98188 • Phone: 206- 431 -3670 • Fax: 206 - 431 -3665 March 31, 2006 Dear Mr. Miles: RECEIVED IMAR 3 1 2006 COMMUNil City of Tukwila DEVELOPMENT Department of Community Development Attn: Mr. Brandon Miles, Assistant Planner 6300 Southcenter Boulevard, Suite 100 Tukwila, WA 98188 Subject: Proposed T- Mobile Wireless Facility 3118 South 140 Street This letter accompanies the following: o Corrected Mailing Labels and 500' buffer map • Revised drawings • Please accept my apology for the delay on my part in getting corrected labels to you. The drawing revision is reflected on sheet A -2. The height was raised 3' in order to meet the minimum height required based on the RF drive test. Also, the cross is increased in size by 25 %. The proposed dimensions are approximately 5' 7" x 11' 3 ". Rather than have to slip sheet the changes I am providing complete sets. Please let me know if I can answer any questions. Sincerely, Chris Listfjeld T--Mobile T Muhi•e I1.`,R. ''c. 1 WW1 January 17, 2006 Dear Mr. Listfjeld: s City of Tukwila Department of Community Development Steve Lancaster, Director Mr. Chris Listfjeld T- Mobile USA 19807 North Creek Parkway N Bothell, WA 98011 RE: Notice of Incomplete Application E05 -021 and L05 -080 • The City of Tukwila's Planning Department received your application for a Conditional Use Permit and SEPA application on December 30, 2005. On January 17, 2006 it was deemed to be incomplete because certain requirements of the application were not provided. In order for the application to be complete please provide the following: 1. Two sets of mailing labels for all tenants both residential and commercial within 500 feet of the subject property. Please note that the Department shall cancel an incomplete application if the applicant fails to submit the requested information within 90 -days following notification from the Department that the application is incomplete. The Department may extend up to 120 days if the applicant submits a written request for an extension prior to cancellation. The request must clearly demonstrate that the delay is due to circumstances beyond the applicant's control (such as the need for seasonal wetland data) or unusual circumstance not typically faced by other applicants, and that a good faith effort has been made to provide the requested materials (TMC 18.104.070). Once the above - mentioned information is provided, City staff can begin to review the application. If you have any questions, please feel free to call me at (206) 431 -3684 or you can email me at bmiles ci.tukwlla.wa.us. Brandon J. Miles Assistant Planner cc. Nora Gierloff, Planning Supervisor File (L05 -080 and E05 -021) Steven M. Mullet, Mayor 6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone: 206 - 431 -3670 • Fax: 206 - 431 -3665 December 29, 2005 ilee City of Tukwila Department of Cummunity Development Attn: Mr. Brandon Miles, Assistant Planner 6300 Southcenter Bouleard, Suite 100 Tukwila, WA 98188 Subject: Proposed T-Mobile Wireless Facility 3118 South 140 Street Dear Mr. Miles: RECEIVED DEC 3 0 2005 DEVELOPI EN This letter accompanies application submittal requirements for a new stealth designed T- Mobile wireless telecommunication facility located at 3118 South 140 Street in Tukwila. Please contact me directly at (206) 412 -0479 if I may initially answer any questions or provide clarification. I look forward to working with you again. Sincerely, Chris Listfjeld T- Mobile 1 M,Th, IJSk 1'rii11 % : "rrkw:r. , WA Ht]i' EXECUTED at rrJ it- .1- CITY OF TUKWILA Deportment ofConemunity Development 6300 Southcenter Boulevard Tukwila, WA 98188 Telephone: (206) 431 -3670 FAX (206) 431 -3665 1 " - mail: )u planr )ci,tukwila.wa.4lg AFFIDAVIT OF OWNERSHIP AND HOLD HARMLESS PERMISSION TO ENTER PROPERTY S'rA'rF. OF WASI r1NCiTON w COUNTY OF KING The undersigned being duly sworn and upon oath states as follows: I. 1 am the current Owner of the property which is the subject of this application. 2. All statements contained in the applications have ben prepared by me or my agents and are true and correct to the beat of my knowledge 3. llw application is being submitted with my knowledge and consent 4. Ownnx grants the City ns employees, agents, engineers, conuaotors or otter representatives the right to enter upon Owner's real property, located at ` 3 / /)j S, /'yo {` Cr. 7'K4' /44, '.- .2,17./4...? for the purpose of application review, for the limited time necessary to complete that purpose. 5. Owner agrees to hold the City harmless for any loss or damage to persons or property occurring on the private property during the City's entry upon the property, unless the loss or damage is the result of the sole negligence of the City. 6. The City shall, at its discretion , cancel the application without refbnd of fees. if the applicant does not respond to specific requests for items on the "Complete Application Cbcckliet" within ninety (90) dais. 7. Non - responsiveness to a City information request for ninety (90) or more days, shall be cause to cancel the application(s) without refund of fees. (city). (Al* state) on /z. /iq /ef II I alLI s: 1-4/ t/ C , (Signature) On this day personally appeared before me to me known to be the individual alto executed the foregoing instrument and acknowledged that tiyg Ik signed the same as )listher voluntary act and deed for the uses and purposes mentioned therein. SUBSCRIBED AND SWORN TO BEFORE ME ON 11IIS /9 t4 DAY OF ye-7, tom✓ °� 5 NOTARY PUBLIC in a residing at �.Lo My Commission expires on /1 -a- g FOR STAFF USE ONLY Sierra Type P -CUP ' Planner: File Number: L0 5 - 6 26 Application Complete (Date: ) Project File Number: Application Incomplete (Date: ) Other File Numbers: • CITY OF TUKWILA Address: 1 � �O 7 Alo, /( dreeiC. Phone: o1fX, 412 DO') Signature: jr T r Department of Community Development 6300 Southcenter Boulevard, Tukwila, WA 98188 Telephone: (206) 431 -3670 FAX (206) 431 -3665 E -mail: tukplan @ci.tukwila.wa.us APPLICATION NAME OF PROJECT/DEVELOPMENT: 7 , le Se 3ss 1 G.lireiess lec0rn.ranb'ce t','oe, CONDITIONAL USE PERMIT LOCATION OF PROJECT/DEVELOPMENT: Give street address or, if vacant, indicate lot(s), block and subdivision, access street, and nearest intersection. LIST ALL TAX LOT NUMBERS. 3 /lg S,utt, 19c S1` Quarter: Section: Township: Range: (This information may be found on your tax statement.) 4, rig 8t if 4,4 /80/2 FAX: / 8 Sa$ i! 3 3 Date: 12'/a 7 /6 S DEVELOPMENT COORDINATOR : The individual who: • has decision making authority on behalf of the applicant in meetings with City stag • has full responsibility for identifying and satisfying all relevant and sometimes overlapping development standards, and • is the primary contact with the City, to whom all notices and reports will be sent Name: (� hri s L is 1' ( i l Check items submitted with application Information Required May be waived in unusual cases, upon approval of both Public ITE Works and Planning � U-C APPLICATION MATERIALS: o f r 1 1. Application Checklist (1 copy) indicating items submitted with application. 2. Completed Application Form and drawings (5 copies). `'-- 3. One set of all plans reduced to 8 1/2" by 11". One complete set of PMTs of the fmal drawing set will be required prior to final approval. 4. Application Fee $2,000. p c ✓ 5. SEPA Environmental Checklist (see SEPA Application Packet). PUBLIC NOTICE MATERIALS: 6. King County Assessor's map(s) that shows the location of each property within 500 ft. of the subject lot. 7. Two (2) sets of mailing labels for all property owners and tenants (residents or businesses) within 500 feet of the subject property. Note: Each unit in multiple -family buildings - -e.g. apartments, condos, trailer parks - -must be included (see Public Notice Materials section of SEPA Application packet). d 8. A 4' x 4' public notice board will be required on site within 14 days of the Department determining that the application is complete (see Public Notice Materials section of SEPA Application packet). PROPERTY INFORMATION: 9. Vicinity Map with site location. 10. If new construction is proposed document sewer and water availability if provided by other than the City of Tukwila. PROJECT DESCRIPTION AND ANALYSIS: 4- 11. A written discussion of project consistency with decision criteria. (See Application) p 12. If additional impervious surface is proposed submit a Technical Information Report (TIR) including feasibility analysis per King County Surface Water Design Manual (KCSWDM). For additional guidance contact Public Works. 13. Provide sensitive area studies as needed per Tukwila's Sensitive Areas Ordinance (TMC 18.45). SITE PLAN. ✓ 14 (a) The site plan must include a graphic scale, north arrow and project name. Maximum size 24 "x36 ". (b) Existing and proposed building footprints. --- (c) Dash in required setback distances from all parcel lot lines. COMPLETE APPLICATION CHECKLIST The materials listed below must be submitted with your application unless specifically waived in writing by the Public Works Department and the Department of Community Development. Please contact each Department if you feel that certain items are not applicable to your project and should be waived, or should be submitted at a later date for use at the public hearing (e.g. colored renderings). Application review will not begin until it is determined to be complete. ADDITIONAL MATERIALS MAY BE REQUIRED. The initial application materials allow starting project review and vesting the applicant's rights. However, they in no way limit the City's ability to require additional information as needed to establish consistency with development standards. City staff are available to answer questions about application materials at 206 - 431 -3670 (Department of Community Development) and 206 -433 -0179 (Department of Public Works). 2n Check items submitted with application Information Required May be waived in unusual cases, upon approval of both Public Works and Planning (d) Fire access lanes and turn - arounds per Fire Department standards. (e) Parking lots with dimensioned stalls and drive aisles. (f) Loading and service areas. ✓ (g) Fences, rockeries and retaining walls. t / (h) Pedestrian connections between the building entrance(s) and the sidewalk/public street. LANDSCAPE PLAN: 4/i9 15 (a) Landscape planting plan by a Washington State licensed landscape architect. One set of all plans and analyses shall have an original Washington State registered Landscape Architect stamp and signature. Plans must include the type, quantity, spacing and location of all plantings. Maximum size 24" x 36 ". N d (b) Show all existing trees to be retained and any tree protection measures required (for example fencing at drip line). SENSITIVE AREAS PLAN: A k 16 (a) Location of all sensitive areas (e.g. streams, wetlands, slopes over 20%, coal mine areas and important geological and archaeological sites). For stream frontage provide existing and proposed top of stream bank, stream bank toe, stream mean high water mark, and base flood elevation (i.e., 100 yr. flood). Maximum size 24" x 36 ". olg (b) Location of all required sensitive area buffers, setbacks tracts and protection measures. ✓ (c) Show all trees over 4" caliper, indicating those to be retained. n//i (d) Proposed lot and tract lines. CIVIL PLANS (If any site changes are proposed): y✓h 17 (a) One set of all civil plans and analyses shall be stamped, signed and dated by a licensed professional engineer. Include a graphic scale and north arrow. Maximum size 24" x 36 ". (b) Vertical datum NAVD 1988 and horizontal datum NAD 83/91. Conversion calculations to NGVD 1929, if in a flood zone or flood -prone area. (c) Existing (dashed) and proposed (solid) topography at 2' intervals. (d) Total expected cut and fill. (e) Existing and proposed utility easements and improvements, on site and in street (water, sewer, power, natural gas, telephone, cable). Schematic designs to be provided regardless of purveyor (e.g. site line size, location, and size of public main). No capacity calcs, invert depth, valve locations or the like are needed. (f) If additional impervious surface is proposed provide a storm drainage design at least 90% complete, which meets the TIR and KCSWDM. Include all storm drainage maintenance access and safety features. Call out total existing and proposed impervious surface in square feet. (g) Locate the nearest existing hydrant and all proposed hydrants. (h) Show the 100 yr. flood plain boundary and elevation as shown on FEMA maps. (i) Plan, profile and cross - section for any right -of -way improvements. (j) Show planned access to lots, driveways, fire access lanes and turnarounds. OTHER: 18. If new construction is proposed provide dimensioned and scalable building elevations with keyed colors and materials. Show mechanical equipment and/or any proposed screening. 19. If site lighting changes are proposed provide a luminaire plan including location and type of street and site lighting. Include proposed fixture cut sheets, site light levels (foot - candles), and measures to shield adjacent properties from glare. NYC 20. All existing and proposed signage with sign designs and locations. K „}, 21. Any other drawings or materials needed to explain your proposal. S << 4l / «LJ Ste /x.1,4 Set 41 ,Lei See ji iVccL c) REVIEW CRITERIA The review criteria for various types of projects are shown below. Please discuss development consistency with each criteria. Then, refer to the Tukwila Comprehensive Plan for project consistency with the policies. Please note that more than one category of policies may apply. Criteria for Conditional Uses (TMC 18.64.030) 1. The proposed use will not be materially detrimental to the public welfare or injurious to the property or improvements in the vicinity. 2. The proposed use shall meet or exceed the same standards for parking, landscaping, yards and other development regulations that are required in the district it will occupy. 3. The proposed development shall be compatible generally with the surrounding land uses. 4. The proposed use shall be in keeping with the goals and policies of the Comprehensive Land Use Policy Plan. 5. All measures shall be taken to minimize the possible adverse impacts which the proposed use may have on the in area which it is located. ..% M LTAR 7 H SES,5. " •i 331 3118S1 tiOt Ntrtb Eviss en r Ta t til ocatio7n of proposed'pole ,rit Direchonand Ioca1ionophotograph ' -• # WAJER;Eq 3 9807.NotihCreek Parkway)yortti Bathegy6tAgiiiiilegOil , Nt`,Pittmg42 . .5 7 3984541 iFAX:' WSsigtr&VMi& • ve r ( (It Q Qt Existing Coverage Age • g • 4 ", 10 t tsd .SD )! • t ccat I A d a • Indoor Coverage > -76 dBm In Car Coverage -84 to -76 dBm • Outdoor Coverage -91 to -84 dBm • Poor coverage -102 to -91 dBm • No coverage -110 to -102 dBm exam+ o tridoor Coverage 3.-76 dBm to Car Coverage -84 to -76 dBm • Outdoor Coverage -81 to -84 dam • Poor coverage -102 to -91 dBm • No coverage -110 to -102 dBm Existing coverage • • • • OeveT t a !.18!14 rte. 4.14M7 -St. • tq - t J VICINITY MAP 5 -124th 9 /4 1) s loth : Korth • . I•' rn T . ' _ F1 T i 33rd `3 • L . SBatllePlari< _ - N — - at r—..,,._.[ . A - -• 1 3118 8.140th St, F • 1 Seattle, WA, 98168 S- 1-421d St" - + 5 14th 51- <• m 5146th -- - • A SeaTaD -5 14 -4 • FROM T- MOBILE BOTHELL 4 OFFICE ARRIVE 3118 S 140TH ST DISTANCE: 28 MILES APPROXIMATE TRAVEL TIME: 32 MINUTES N Tukwila 5 moth R 9 • — &t h n ..1526:1 R { 5 DRIVING DIRECTIONS 1. Take Ramp (LEFT) onto 1405 (1405 / Renton) 24.4 2. Road name changes to SR5181.1 3. Tum RIGHT onto Ramp (WA-99 / Sea-Tac Airport) 0.3 4. Keep RIGHT to stay on Ramp (WA-99 / WA-99 N) < 0.1 5. Keep LEFT to stay on Ramp (WA-99 N) < 0.1 6. Keep RIGHT to stay on Ramp (S. 154th SL / WA-99 N) <0.1 7. Bear RIGHT (East) onto S 154th SL then Immediately turn LEFT (Nonh) onto SR-99 (International Blvd) 1.0 8. Tum LEFT (West) onto S 140th St 0.4 Fost1 SITE NUMBER: SE3551C OGRAM MANAGER: 156 •• Fe "1 ' alt CONSTRUCTION PROJECT _ , MANAGER: ,Y. i5 CONSULTING 10 tlf ENGINEER: 548 SITE ACQUISITION: 15 LATITUDE 47° 28' 42.2" N LONGITUDE 122° 17' 32.8" W CONTACT TITLE CONTACT INFORMATION PROPERTY OWNER: ZONING: MILITARY PROJECT TEAM RIVERTON PK UNITED METH CH 3118 S 140TH ST TUKWILA, WA98168 VOICESTREAM WIRELESS MIKE PUTT 19807 NORTH CREEK PKWY N BOTHELL, WA 98011 OFFICE S/: 425398.7593 VOICESTREAM WIRELESS TAI IRISH 19807 NORTH CREEK PKWY N BOTHELL, WA 98011 425 - 273-6864 B. J. THOMAS, P.E. 7607 80TH AVE NE MARYSVILLE, WA 98270 MOBILE /h 206 -851 -1106 VOICESTREAM WIRELESS BJORN MORFIN 19807 NORTH CREEK PKWY N BOTHELL, WA 98011 503-781-9762 VOICESTREAM WIRELESS CHRIS LISTFJELD 19807 NORTH CREEK PKWY N BOTHELL, WA 98011 MOBILES/ 206-412-0479 Vo 'ce S t,eam ° W I R E L E S S Global Wireless by T • Mobile PROJECT INFORMATION THIS IS UNSTAFFED AND RESTRICTED EQUIPMENT AND WILL BE USED FOR THE TRANSMISSION OF RADIO SIGNALS FOR THE PURPOSE OF PROVIDING PUBLIC CELLULAR SERVICE. 3118 S 140TH ST TUKWILA, WA 98168 VOICESTREAM WIRELESS CERTIFIES THAT THIS TELEPHONE EQUIPMENT FACILITY WILL BE SERVICED ONLY BY VOICESTREAM WIRELESS EMPLOYEES AND THE WORK ASSOCIATED WITH ANY EQUIPMENT CANNOT BE PERFORMED BY HANDICAPPED PERSONS. THIS FACILITY WILL BE FREQUENTED ONLY BY SERVICE PERSONNEL FOR REPAIR PURPOSES. PURSUANT TO THE AMERICANS WITH DISABILITIES ACT (ADA), APPENDIX B SECTION 4,11. (5Xb), THIS FACILITY IS EXEMPT FROM THAT ACT. NO POTABLE WATER SUPPLY IS TO BE PROVIDED AT THIS LOCATION. NO WASTE WATER OR SOLID WASTE WILL BE GENERATED AT THIS LOCATION. VOICESTREAM WIRELESS MAINTENANCE CREW (ONE PERSON) WILL MAKE AN AVERAGE OF ONE TRIP PER MONTH AT ONE HOUR PER TRIP. CODE COMPLIANCE ALL WORK AND MATERIALS SHALL BE PERFORMED AND INSTALLED IN ACCORDANCE WITH THE CURRENT EDITIONS OF THE FOLLOWING CODES AS ADOPTED BY THE LOCAL GOVERNING AUTHORTRES. NOTHING ON THESE PLANS IS TO BE CONSTRUCTED TO PERMIT WORK NOT CONFORMING TO THESE CODES: 2003 INTERNATIONAL BUILDING CODE 2003 INTERNATIONAL RESIDENTIAL CODE 2003 INTERNATIONAL MECHANICAL CODE 2003 INTERNATIONAL FUEL GAS CODE 2002 NFPA 54 - NATIONAL FUEL GAS CODE (PROPANE INSTALLATIONS ONLY) 2001 NFPA 58- UQUIEFIED PETROLEUM GAS CODE (PROPANE INSTALLATIONS ONLY) 2003 INTERNATIONAL FIRE CODE 2003 UNIFORM PLUMBING CODE 21103 NATIONAL ELECTRICAL CODE 2003 NATIONAL ELECTRIC SAFETY CODE LOCAL BUILDING CODE ORDINANCES ANSI /TW / EIA - 222 - F NFPA -101 - UFE SAFETY CODE 27TH PROJECT DESCRIPTION VOICESTREAM WIRELESS ANTENNAS COLLOCATED ON AN EXISTING 53' AGL STEEL MONOPOLE WITH BTS EQUIPMENT IN A 8'-6 x 16'.0 FENCED HALF VAULT LEASE AREA ZONING INFORMATION SITE NUMBER: SE3551C SITE NAME: MILITARY 8 27TH SITE ADDRESS: 3118 S 140TH ST TUKWILA, WA 98168 PARCEL 1623049162 CURRENT ZONING: LDR GOVERNING CODE: 2003 /BC BUILDING TYPE SITE TYPE UNSTAFFED TELECOM FACILITY LEGAL DESCRIPTION ABBREVIATED PER ACCESSOR RECORDS: E 225 FT OF S 395 FT OF NE 1/4 OF SE 1/4 TGW W 1 FT OF E 228 FT OF S 200 FT LESS CO RD DWG T -1 G-1 A -1 A -1.1 A -2 A-3 A-4 A-5 8-5.1 E -1 E -2 0-3 E-4 RF -1, RF -2 PROPERTY OWNER: T- MOBILE PGM RF ENGINEER: CONSTRUCTION: ZONING: LEASING: ENGINEERING: TITLE SHEET GENERAL NOTES SITE PLAN ENLARGED SITE PLAN PROPOSED SITE ELEVATION BTS EQUIPMENT DETAILS GENERAL DETAILS HALF VAULT DETAILS HALF VAULT ELEVATIONS ELECTRICAL SITE PLAN ELECTRICAL GROUNDING PLAN ELECTRICAL GROUNDING DETAILS ELECTRICAL DETAILS RF DETAILS DRAWING INDEX DRAWING DESCRIPTION APPROVALS p r T sour( PREG41n0NSWsu u BY TELCUV'tlW:CE CONTIWTONS) AT ALL TRIEKCHTG ACCOFCINCE MTN OJR ENT OSHASTNAVOS DATE: DATE: DATE: DATE: DATE: DATE: DATE: CALL 3 WORKING DAYS BEFORE YOU DIG 1- 800 - 424 -5555 UTILITIES UNDERGROUND LOCATION CENTER (ID,MT,ND,OR,WA) BECreC- RE0 SEWER CPENNN GA5Ca. rows SUIVEY•t4K Ri0PDaE0 -MITE WATBT.BLE 19807 NORTHCREEK PKWY N BOTHELL, WA 98011 OFFICE (425) 398.7000 _PROJECT INFORMATION. MILITARY & 27TH SE3551 C 3118 S 140TH ST TUKWILA. WA 98168 - ISSUED FOR: C BUILDING PERMIT REVISION HISTORY: No- DATE: DESCRIPTION: CHK. APPY. BY: BY: F 8/152006 ISSUED FOR BUILDING PERMIT BJT MP 3/132006 MINOR REVISIONS BJT MP 1229/2005 ISSUED FOR ZONING BJT MP 12/15/2005 ISSUED DESIGN REVIEW BJT MP - PLANS PREPARED BY: B. J. THOMAS, P.E. 7607 80TH AVE NE MARYSVILLE, WA 98270 206.851.1106 FD RAWN BY: CHK. BY: =APPV. BY:= AAL BJT AM _ LICENSURE• ,T H 0 c. WA4y�4' 37 b1HAL EXPIRES 082307 EQUIPMENT: VOICESTREAM WIRELESS ANTENNAS COLLOCATED ON AN EXISTING 53' AGL STEEL MONOPOLE WITH BTS EQUIPMENT IN A 8'-6 x 16'-7 FENCED HALF VAULT LEASE AREA. DRAWING INFORMATION: DO NOT SCALE DRAWINGS. CONTRACTOR MUST VERIFY ALL DIMENSIONS AND ADVISE CONSULTANTS OF ANY ERRORS AND OMISSIONS. ALL PREVIOUS ISSUES OF THIS DRAWING ARE SUPERSEDED BY THE LATEST REVISION. THE INFORMATION CONTAINED IN THIS SET OF DOCUMENTS IS PROPRIETARY BY NATURE. ANY USE OR DISCLOSURE OTHER THAN WHICH IS RELATED TO NAMED CLIENT IS STRICTLY PROHIBITED. DRAWING TITLE. TITLE SHEET DRAWING NUMBER: T .. 1 OeveT t a !.18!14 rte. 4.14M7 -St. • tq - t J VICINITY MAP 5 -124th 9 /4 1) s loth : Korth • . I•' rn T . ' _ F1 T i 33rd `3 • L . SBatllePlari< _ - N — - at r—..,,._.[ . A - -• 1 3118 8.140th St, F • 1 Seattle, WA, 98168 S- 1-421d St" - + 5 14th 51- <• m 5146th -- - • A SeaTaD -5 14 -4 • FROM T- MOBILE BOTHELL 4 OFFICE ARRIVE 3118 S 140TH ST DISTANCE: 28 MILES APPROXIMATE TRAVEL TIME: 32 MINUTES N Tukwila 5 moth R 9 • — &t h n ..1526:1 R { 5 DRIVING DIRECTIONS 1. Take Ramp (LEFT) onto 1405 (1405 / Renton) 24.4 2. Road name changes to SR5181.1 3. Tum RIGHT onto Ramp (WA-99 / Sea-Tac Airport) 0.3 4. Keep RIGHT to stay on Ramp (WA-99 / WA-99 N) < 0.1 5. Keep LEFT to stay on Ramp (WA-99 N) < 0.1 6. Keep RIGHT to stay on Ramp (S. 154th SL / WA-99 N) <0.1 7. Bear RIGHT (East) onto S 154th SL then Immediately turn LEFT (Nonh) onto SR-99 (International Blvd) 1.0 8. Tum LEFT (West) onto S 140th St 0.4 Fost1 SITE NUMBER: SE3551C OGRAM MANAGER: 156 •• Fe "1 ' alt CONSTRUCTION PROJECT _ , MANAGER: ,Y. i5 CONSULTING 10 tlf ENGINEER: 548 SITE ACQUISITION: 15 LATITUDE 47° 28' 42.2" N LONGITUDE 122° 17' 32.8" W CONTACT TITLE CONTACT INFORMATION PROPERTY OWNER: ZONING: MILITARY PROJECT TEAM RIVERTON PK UNITED METH CH 3118 S 140TH ST TUKWILA, WA98168 VOICESTREAM WIRELESS MIKE PUTT 19807 NORTH CREEK PKWY N BOTHELL, WA 98011 OFFICE S/: 425398.7593 VOICESTREAM WIRELESS TAI IRISH 19807 NORTH CREEK PKWY N BOTHELL, WA 98011 425 - 273-6864 B. J. THOMAS, P.E. 7607 80TH AVE NE MARYSVILLE, WA 98270 MOBILE /h 206 -851 -1106 VOICESTREAM WIRELESS BJORN MORFIN 19807 NORTH CREEK PKWY N BOTHELL, WA 98011 503-781-9762 VOICESTREAM WIRELESS CHRIS LISTFJELD 19807 NORTH CREEK PKWY N BOTHELL, WA 98011 MOBILES/ 206-412-0479 Vo 'ce S t,eam ° W I R E L E S S Global Wireless by T • Mobile PROJECT INFORMATION THIS IS UNSTAFFED AND RESTRICTED EQUIPMENT AND WILL BE USED FOR THE TRANSMISSION OF RADIO SIGNALS FOR THE PURPOSE OF PROVIDING PUBLIC CELLULAR SERVICE. 3118 S 140TH ST TUKWILA, WA 98168 VOICESTREAM WIRELESS CERTIFIES THAT THIS TELEPHONE EQUIPMENT FACILITY WILL BE SERVICED ONLY BY VOICESTREAM WIRELESS EMPLOYEES AND THE WORK ASSOCIATED WITH ANY EQUIPMENT CANNOT BE PERFORMED BY HANDICAPPED PERSONS. THIS FACILITY WILL BE FREQUENTED ONLY BY SERVICE PERSONNEL FOR REPAIR PURPOSES. PURSUANT TO THE AMERICANS WITH DISABILITIES ACT (ADA), APPENDIX B SECTION 4,11. (5Xb), THIS FACILITY IS EXEMPT FROM THAT ACT. NO POTABLE WATER SUPPLY IS TO BE PROVIDED AT THIS LOCATION. NO WASTE WATER OR SOLID WASTE WILL BE GENERATED AT THIS LOCATION. VOICESTREAM WIRELESS MAINTENANCE CREW (ONE PERSON) WILL MAKE AN AVERAGE OF ONE TRIP PER MONTH AT ONE HOUR PER TRIP. CODE COMPLIANCE ALL WORK AND MATERIALS SHALL BE PERFORMED AND INSTALLED IN ACCORDANCE WITH THE CURRENT EDITIONS OF THE FOLLOWING CODES AS ADOPTED BY THE LOCAL GOVERNING AUTHORTRES. NOTHING ON THESE PLANS IS TO BE CONSTRUCTED TO PERMIT WORK NOT CONFORMING TO THESE CODES: 2003 INTERNATIONAL BUILDING CODE 2003 INTERNATIONAL RESIDENTIAL CODE 2003 INTERNATIONAL MECHANICAL CODE 2003 INTERNATIONAL FUEL GAS CODE 2002 NFPA 54 - NATIONAL FUEL GAS CODE (PROPANE INSTALLATIONS ONLY) 2001 NFPA 58- UQUIEFIED PETROLEUM GAS CODE (PROPANE INSTALLATIONS ONLY) 2003 INTERNATIONAL FIRE CODE 2003 UNIFORM PLUMBING CODE 21103 NATIONAL ELECTRICAL CODE 2003 NATIONAL ELECTRIC SAFETY CODE LOCAL BUILDING CODE ORDINANCES ANSI /TW / EIA - 222 - F NFPA -101 - UFE SAFETY CODE 27TH PROJECT DESCRIPTION VOICESTREAM WIRELESS ANTENNAS COLLOCATED ON AN EXISTING 53' AGL STEEL MONOPOLE WITH BTS EQUIPMENT IN A 8'-6 x 16'.0 FENCED HALF VAULT LEASE AREA ZONING INFORMATION SITE NUMBER: SE3551C SITE NAME: MILITARY 8 27TH SITE ADDRESS: 3118 S 140TH ST TUKWILA, WA 98168 PARCEL 1623049162 CURRENT ZONING: LDR GOVERNING CODE: 2003 /BC BUILDING TYPE SITE TYPE UNSTAFFED TELECOM FACILITY LEGAL DESCRIPTION ABBREVIATED PER ACCESSOR RECORDS: E 225 FT OF S 395 FT OF NE 1/4 OF SE 1/4 TGW W 1 FT OF E 228 FT OF S 200 FT LESS CO RD DWG T -1 G-1 A -1 A -1.1 A -2 A-3 A-4 A-5 8-5.1 E -1 E -2 0-3 E-4 RF -1, RF -2 PROPERTY OWNER: T- MOBILE PGM RF ENGINEER: CONSTRUCTION: ZONING: LEASING: ENGINEERING: TITLE SHEET GENERAL NOTES SITE PLAN ENLARGED SITE PLAN PROPOSED SITE ELEVATION BTS EQUIPMENT DETAILS GENERAL DETAILS HALF VAULT DETAILS HALF VAULT ELEVATIONS ELECTRICAL SITE PLAN ELECTRICAL GROUNDING PLAN ELECTRICAL GROUNDING DETAILS ELECTRICAL DETAILS RF DETAILS DRAWING INDEX DRAWING DESCRIPTION APPROVALS p r T sour( PREG41n0NSWsu u BY TELCUV'tlW:CE CONTIWTONS) AT ALL TRIEKCHTG ACCOFCINCE MTN OJR ENT OSHASTNAVOS DATE: DATE: DATE: DATE: DATE: DATE: DATE: CALL 3 WORKING DAYS BEFORE YOU DIG 1- 800 - 424 -5555 UTILITIES UNDERGROUND LOCATION CENTER (ID,MT,ND,OR,WA) BECreC- RE0 SEWER CPENNN GA5Ca. rows SUIVEY•t4K Ri0PDaE0 -MITE WATBT.BLE GENERAL NOTES: 1. DRAWINGS ARE NOT TO BE SCALED, WRITTEN DIMENSIONS TAKE PRECEDENCE, THIS SET OF DOCUMENTS IS INTENDED TO BE USED FOR DIAGRAMMATIC PURPOSED ONLY. UNLESS NOTED OTHERWISE THE GENERAL CONTRACTORS SCOPE OF WORK SHALL INCLUDE FURNISHING ALL MATERIALS, EQUIPMENT, LABOR AND ANY REQUIREMENTS DEEMED NECESSARY TO COMPLETE INSTALLATION AS DESCRIBED INTHE DRAWINGS AND OWNERS PROJECT MANUAL 2. THE CONTRACTOR IS RESPONSIBLE FOR ALL DIMENSIONS AND STANDARDIZED DETAILS THAT REQUIRE MODIFICATIONS DUE TO ACTUAL FIELD CONDITIONS AND REQUIREMENTS MUST BE SUBMITTED TO AND APPROVED BY, VOICESTREAM WIRELESS REPRESENTATIVE PRIOR TO START OF WORK 3. PRIOR TO THE SUBMISSION OF BIDS, CONTRACTORS INVOLVED SHALL VISIT THE JOB SITE TO FAMILIARIZE THEMSELVES WITH ALL CONDITIONS AFFECTING THE PROPOSED PROJECT. CONTRACTORS SHALL VISIT THE CONSTRUCTION SITE WITH THE CONSTRUCTION /CONTRACT DOCUMENTS TO VERIFY FIELD CONDITIONS AND CONFIRM THAT THE PROJECT WILL BE ACCOMPLISHED AS SHOWN. PRIOR TO PROCEEDING WITH CONSTRUCTOR, ANY ERRORS, OMISSIONS, OR DISCREPANCIES SHALL BE BROUGHT TO THE ATTENTION OF THE ARCHITECT/ENGINEER VERBALLY AND IN WRITING. 4. THE GENERAL CONTRACTOR SHALL RECEIVE WRITTEN AUTHORIZATION TO PROCEED WITH CONSTRUCTOR PRIOR TO STARTING WORK ON ANY ITEM NOT CLEARLY DEFINED BY THE CONSTRUCTION DRAWINGS/CONTRACT DOCUMENTS. 5 THE CONTRACTOR SHALL SUPERVISE AND DIRECT THE PROJECT DESCRIBED IN THE CONTRACT DOCUMENTS. THE CONTRACTOR SHALL BE SOLELY RESPONSIBLE FOR ALL CONSTRUCTION MEANS, METHODS, TECHNIQUES, SEQUENCES, SAFETY, AND PROCEDURES FOR COORDINATING ALL PORTIONS OF THE WORK UNDER THE CONTRACT. 6 THE CONTRACTOR SHALL INSTALL ALL EQUIPMENT AND MATERIALS ACCORDING TO MANUFACTURER'SNENDORS SPECIFICATIONS UNLESS NOTED OTHERWISE OR WHERE LOCAL CODES OR ORDINANCES TAKE PRECEDENCE. 7 ALL WORK PERFORMED ON THE PROJECT AND MATERIALS INSTALLED SHALL BE IN STRICT ACCORDANCE WITH ALL APPLICABLE CODES REGULATIONS. AND ORDINANCES. CONTRACTOR SHALL GIVE ALL NOTICES AND COMPLY WITH ALL LAWS, ORDINANCES, RULES, REGULATIONS AND LAWFUL ORDERS OF ANY PUBLIC AUTHORITY, MUNICIPAL AND UTILITY COMPANY SPECIFICATIONS, AND LOCAL AND STATE JURISDICTIONAL CODES BEARING ON THE PERFORMANCE OF THE WORK. 8 GENERAL CONTRACTOR SHALL PROVIDE, AT THE PROJECT SITE, A FULL SET OF CONSTRUCTION DOCUMENTS UPDATED WITH THE LATEST REVISIONS INVOLVED WITH THE PROJECT. THIS SET IS A VALID CONTRACT DOCUMENT ONLY IF THE TITLE SHEET IS STAMPED IN RED INK FOR CONSTRUCTION" AND EACH SUCCESSIVE SHEET BEARS THE ARCHITECTS/ENGINEERS SIGNED WET STAMP. 9 THE CONTRACTOR IS RESPONSIBLE FOR ADEQUATELY BRACING AND PROTECTING ALL WORK DURING CONSTRUCTION AGAINST DAMAGE. BREAKAGE. COLLAPSE. ETC. ACCORDING TO APPLICABLE CODES. STANDARDS, AND GOOD CONSTRUCTION PRACTICES. 10. THE CONTRACTOR SHALL MEET ALL OSHA REQUIREMENTS FOR ALL INSTALLATIONS. 11 THE CONTRACTOR SHALL BE RESPONSIBLE FOR ALL DAMAGES TO THE EXISTING CONSTRUCTOR AND REPAIR ALL DAMAGES TO BETTER THAN NEW CONSTRUCTION. THE CONTRACTOR SHALL NOTIFY THE CONSULTANT OF ANY DAMAGE TO 1110 BUILDING SITE OR ANY ADJACENT STRUCTURES AROUND THE PROJECT. THE T- MOBILE REPRESENTATIVE SHALL BE SOLE AND FINAL JUDGE AS TO THE QUALITY OF THE REPAIRED CONSTRUCTOR. ANY ADDITIONAL MODIFICATIONS WHICH MUST BE MADE SHALL BE MADE AT THE CONTRACTORS EXPENSE. 12. WHERE NEW PAVING, CONCRETE SIDEWALKS OR PATHS MEET EXISTING CONSTRUCTION, THE CONTRACTOR SHALL MATCH THE EXISTING PITCH. GRADE. AND ELEVATION SO THE ENTIRE STRUCTURE SHALL HAVE A SMOOTH TRANSITION. 13 THE CONTRACTOR SHALL MODIFY THE EXISTING FLOORS. WALL CEILING, OR OTHER CONSTRUCTION AS REQUIRED TO GAIN ACCESS TO AREAS FOR ALL MECHANICAL PLUMBING, ELECTRICAL OR STRUCTURAL MODIFICATIONS. WHERE THE EXISTING CONSTRUCTION DOORS, PARTITIONS, CEILING, ETC., ARE TO BE REMOVED, MODIFIED, OR REARRANGED OR WHERE THE EXPOSED OR HIDDEN MECHANICAL ELECTRICAL, SYSTEMS ARE ADDED OR MODIFIED, THE GENERAL CONTRACTOR SHALL REPAIR. PATCH AND MATCH ALL EXISTING CONSTRUCTION AND FINISHES OF ALL FLOORS WALLS AND CEILINGS. WHERE CONCRETE MASONRY CONSTRUCTION IS MODIFIED, THE CONTRACTOR SHALL TOOTH IN ALL NEW CONSTRUCTION TO MATCH THE EXISTING BOND. WHERE CONCRETE CONSTRUCTION IS MODIFIED, THE CONTRACTOR SHALL VERIFY THE EXACT DETAILS TO BE USED FOR CONSTRUCTION. ALL WORK SHALL BE COVERED UNDER THE GENERAL CONTRACT. 14 IF CONTRACTOR OR SUBCONTRACTOR FIND R NECESSARY TO DEVIATE FROM ORIGINAL APPROVED PLANS. THEN IT LS THE CONTRACTORS AND THE SUBCONTRACTORS RESPONSIBILITY TO PROVIDE THE CONSULTANT WITH 4 COPIES OF THE PROPOSED CHANGES FOR HIS APPROVAL BEFORE PROCEEDING WITH THE WORK. IN ADDITION THE CONTRACTOR AND SUBCONTRACTORS SHALL BE RESPONSIBLE FOR PROCURING AU. NECESSARY APPROVALS FROM THE BUILDING AUTHORITIES FOR THE PROPOSED CHANGES BEFORE PROCEEDING WITH THE WORK THE CONTRACTOR AND SUBCONTRACTORS SHALL BE RESPONSIBLE FOR PROCURING ALL NECESSARY INSPECTIONS AND APPROVALS FROM BUILDING AUTHORITIES DURING THE EXECUTION OF THE WORK. 15 CONTRACTOR TO PROVIDE A PORTABLE FIRE EXTINGUISHER WITH A RATING OF NOT LESS THAN 2-A OR 2,A108C WITHIN 75 FEET TRAVEL DISTANCE TO ALL PORTIONS OF PROJECT AREA DURING CONSTRUCTOR. 16 THE CONTRACTOR SHALL PERFORM WORK DURING OWNER'S PREFERRED HOURS TO AVOID DISTURBING NORMAL BUSINESS. 17 SEAL ALL PENETRATIONS THROUGH FIRE-RATED AREAS WITH U.L. LISTED OR FIRE MARSHAL APPROVED MATERIALS AS APPLICABLE TO THIS FAC ILITY AND OR PROJECT SITE. 18 CONTRACTOR SHALL BE RESPONSIBLE FOR UTILITY LOCATES, SCHEDULING, COORDINATING SPECIAL AND BUILDING DEPARTMENT INSPECTIONS. 19. CONTRACTOR SHALL BE RESPONSIBLE FOR CONTACTING AND UTILIZING ORIGINAL ROOFING CONTRACTOR AS REQUIRED TO MAINTAIN ANY EXISTING ROOFING WARRANTY. 20 ROUTING OF ALL CONDUITS. CABLES, CABLE TRAYS ETC ARE INDICATED AS PROPOSED LOCATION ONLY. CONFIRM THE EXACT LOCATION AND ROUTING WITH THE ON SIZE T- MOBILE CONSTRUCTOR MANAGER PRIOR TO STARTING WORK. CONCRETE NOTES: 1. ALL CONCRETE WORK SHALL BE IN ACCORDANCE WITH THE ACI 301, ACI 318 AND THE SPECIFICATION CAST-IN-PLACE CONCRETE. 2. ALL CONCRETE SHALL HAVE A MINIMUM COMPRESSIVE STRENGTH OF 2500 PSI AT 28 DAYS UNO. 3. REINFORCING STEEL SHALL CONFORM TO ASTM A 615. GRADE 60, DEFORMED UNLESS NOTED OTHERWISE. WELDED WIRE FABRIC SHALL CONFORM TO ASTM A 185 WELDED STEEL WIRE FABRIC UNLESS NOTED OTHERWISE. SPLICES CLASS "B" AND ALL HOOKS SHALL BE STANDARD UNO. 4 THE FOLLOWING MINIMUM CONCRETE COVER SHALL BE PROVIDED FOR REINFORCING STEEL UNLESS SHOWN OTHERWISE ON DRAWINGS: CONCRETE GIST AGAINST EARTH • 3 IN. CONCRETE EXPOSED TO EARTH OR WEATHER: 46 AND LARGER 21N. #5 AND SMALLER 8 W WF 1121N. 5 A 1& TROWELED RADIUS SHALL BE PROVIDED AT ALL EXPOSED EDGES OF CONCRETE UNO. HOLES TO RECEIVE EXPANSION/WEDGE ANCHORS SHALL BE 1/8 LARGER IN DIAMETER THAN THE ANCHOR BOLT, DOWEL OR ROD AND SHALL CONFORM TO MFR RECOMMENDATION FOR EMBEDMENT DEPTH OR AS SHOWN ON THE DRAWINGS. AVOID CUTTING EXISTING REBAR WHEN DRILLING HOLES IN THE ELEVATED SLAB. 6 INSTALLATION OF CONCRETE EXPANSION/WEDGE ANCHOR SHALL BE PER MANUFACTURER'S WRITTEN RECOMMENDED PROCEDURES. 7 FLOAT SURFACE SHALL BE A SMOOTH FINISH. SURFACE SHALL BE FREE OF ALL OBVIOUS DEPRESSIONS. SURFACE SHALL BE SLOPED AT 28 TO PROMOTE DRAINAGE AWAY FROM EQUIPMENT. SITE WORK NOTES: 1 RUBBISH, STUMPS, DEBRIS, STICKS, STONES AND OTHER REFUSE SHALL BE REMOVED FROM THE SITE AND DISPOSED OF LEGALLY. 2 THE SITE SHALL BE GRADED TO CAUSE SURFACE WATER TO FLOW AWAY FROM THE PCS EQUIPMENT, TOWER AREAS, AND ADJACENT BUILDINGS. 3 NO FILL OR EMBANKMENT MATERIAL SHALL BE PLACED ON FROZEN GROUND. FROZEN MATERIALS, SNOW OR ICE SHALL NOT BE PLACED IN ANY FILL OR EMBANKMENT. 4. THE SUBGRADE SHALL BE COMPACTED AND BROUGHT TOA SMOOTH UNIFORM GRADE PRIOR TO THE CRUSHED STONE APPLICATION. 5 ALL EXISTING ACTIVE SEWER, WATER, GAS, ELECTRIC, AND OTHER UTILITIES WHERE ENCOUNTERED IN THE WORK SHALL BE PROTECTED AT ALL TIMES. AND WHERE REQUIRED FOR THE PROPER EXECUTION OF THE WORK SHALL BE RELOCATED AS DIRECTED BY ENGINEERS. EXTREME CAUTION SHOULD BE USED BY THE CONTRACTOR WHEN EXCAVATING OR PIER DRILLING AROUND OR NEAR UTILITIES. CONTRACTOR SHALL PROVIDE SAFETY TRAINING FOR THE WORKING CREW. 6. ALL EXISTING INACTIVE SEWER, WATER, GAS, ELECTRIC AND OTHER UTILITIES, WHICH INTERFERE WITH THE EXECUTION OF THE WORK, SHALL BE REMOVED AND SHALL BE CAPPED, PLUGGED OR OTHERWISE DISCONTINUED AT POINTS WHICH WILL NOT INTERFERE WITH THE EXECUTION OF THE WORK, SUBJECT TO THE APPROVAL OF ENGINEERING. 7 THE AREAS OF THE CUSTOMERS PROPERTY DISTURBED BY THE WORK AND NOT COVERED BY THE BUILDING. DRIVEWAY OR CRUSHED STONE. SHALL BE GRADED TO A UNIFORM SLOPE. FERTILIZED, SEEDED, AND COVERED WITH MULCH AS SPECIFIED IN 1110 SPECIFICATION LANDSCAPE WORK. 8 BEDDING MATERIAL FOR UTILITY LINES, CULVERTS AND PIPING: CLEAN SAND, MEDIUM TP COARSE, SUB ROUNDED NATURAL RIVER OR BANK SAND, WASHED. FREE OF SILT OR CLAY, LOAM, FRIABLE OR SOLUBLE MATERIALS. AND ORGANIC MATER; GRADED IN ACCORDANCE WITH THE FOLLOWING GRAIN SIZE DISTRIBUTOR: SIEVE SIZE 3/8• NO. 4 MESH NO 8 MESH NO 16 MESH NO 100 MESH NO 200 MESH PERCENT PASSING 100 60.90 0-45 0-25 0-2 0-2 9. BMPS FOR TEMPORARY EROSION/SEDIMENTATION CONTROL SHALL BE IMPLEMENTED PER LOCAL CITY OR COUNTY GUIDELINES AND PER PLAN IF APPUCABLE. ABBREVIATIONS AC AFF AFG AFS ALUM AB L ARCH BITS BLDG BM BOT B.O. BOO BOS CJ C LG CUR CMU COL CONC CONST CONT CTR DIA /0 DT- (E) EA EJ ELEC EL EO EW EXP EXT FD FIN FIN FL8 FL8 FTG GA GALV GYP GB HM HOR HR HT HVAC INSUL INT AIR CONDITIONER ABOVE FINISHED FLOOR ABOVE RNISHED GRADE ABOVE FINISHED SLAB ALUMINUM ANCHOR BOLT ANGLE ARCHITECTURAL BASE TRANSMISSION SYSTEM BUILDING BEAM BOTTOM BOTTOM OF BOTTOM OF CONCRETE BOTTOM OF STEEL CONTROL JOINT CENTER LINE CEILING CLEAR CONCRETE MASONRY UNIT COLUMN CONCRETE CONSTRUCTOR CONTINUOUS CENTER DIAMETER DETAIL EXISTING EACH EXPANSION JOINT ELECTRIC/ELECTRICAL ELEVATION EQUAL EACH WAY EXPANSION EXTERIOR FLOOR DRAIN FINISH FINISH FLOOR FLOOR FOOTING GAUGE GALVANIZED GYPSUM GYPSUM BOARD HOLLOW METAL HORIZONTAL HOUR HEIGHT HEATING VENTILATION AIR CONDITIONING INSULATION INTERIOR LEGENDS & SYMBOLS CHAINLINK FENCE CEDAR FENCE POWER TELCO POWERITELCO OVERHEAD COAX COAX OVERHEAD POWER CENTERLINE REVISION BUG ELEVATION VIEW BUG ELEVATION DETAIL BUG SECTION BUG - X P - T - T/P - OHC OH JT LAM LF MANUF MAX MECH MM MM MIN MISC MPH MTL NIC NOM NTS OC OD OH OPNG OPP (P) PPS PR PSI PSF PT RAD RD REINF REO'D RM WIN SCHED SECT SF SIM SO FT SS STD STL STRUC TEMP THK T.O. TOS TOC TYP LINO VCT VERT W/ WWM X P T T/P OHC 011 *TOP OF ... EL 0' -0" JOINT LAMINATED LINEAL FOOT MANUFACTURER MAXIMUM MECHANICAL MANHOLE MILLIMETER MINIMUM MISCELLANEOUS MILES PER HOUR METAL NOT IN CONTRACT NOMINAL NOT TO SCALE ON CENTER OUTSIDE DIAMETER OVERHEAD OPENING OPPOSITE PROPOSED PERSONAL COMMUNICATION SYSTEM PLATE PAIR POUNDS PER SQUARE INCH POUNDS PER SQUARE FOOT PRESSURE TREATED RADIUS ROOF DRAIN REINFORCED/REINFORCING REQUIRED ROOM RIGHT OF WAY SCHEDULE SECTION SQUARE FOOT SIMILAR SQUARE FOOT STAINLESS STEEL STANDARD STEEL STRUCTURAL TEMPORARY THICK TOP OF TOP OF STEEL TOP OF CONCRETE TYPICAL UNLESS NOTED OTHERWISE VINYL COMPOSITION TILE VERTICAL WITH WELDED WIRE MESH A \ X X P T T T/P 17P OHC OHC - COAX - COAX - COAX -COAX OH OH DETAIL NUMBER SHEET NUMBER DETAIL NUMBER SHEET NUMBER DETAIL NUMBER SHEET NUMBER IlbKegeam• 19807 NORTHCREEK PKWY N BOTHELL, WA 98011 OFFICE (425) 3967600 — PROJECT INFORMATION* MILITARY & 27TH SE3551 C 3118S140THST TUKWILA, WA 98168 ISSUED FOR: C _REVISION HISTORY: No. DATES DEBCRIPTION, B UILDING PERMIT =PLANS PREPARED BY: B . J. THOMAS, P.E. 7607 80TH AVE NE MARYSVILLE, WA 98270 206. 851.1106 C DRAWN BY: - LICENSURE• AAL BJT AM r EQUIPMENT: _DRAWING INFORMATION: VOICESTREAM WIRELESS ANTENNAS COLLOCATED ON AN EXISTING 53' AGL STEEL MONOPOLE WITH BITS EQUIPMENT IN A 8'6- x 16'-0 FENCED HALF VAULT LEASE AREA. DO NOT SCALE DRAWINGS. CONTRACTOR MUST VERIFY ALL DIMENSIONS AND ADVISE CONSULTANTS OF ANY ERRORS AND OMISSIONS. ALL PREVIOUS ISSUES OF THIS DRAWING ARE SUPERSEDED BY THE LATEST REVISION. THE INFORMATION CONTAINED IN THIS SET OF DOCUMENTS IS PROPRIETARY BY NATURE. ANY USE OR DISCLOSURE OTHER THAN WHICH IS RELATED TO NAMED CLIENT IS STRICTLY PROHIBITED. - DRAWING TITLE: DRAWING NUMBER: CHK. APPV. BY: BY: CHK. BY: = APPV. BY:: GENERAL NOTES G -1 / / 4� � A 2152 ISSUED FOR BUILDING PERMIT BJT MP /3\ 3/13/2006 MINOR REVISIONS BJT MP / ` \ 12292005 ISSUED FOR ZONING BJT MP / /' \ 12/15/2005 ISSUED DESIGN REVIEW BJT MP GENERAL NOTES: 1. DRAWINGS ARE NOT TO BE SCALED, WRITTEN DIMENSIONS TAKE PRECEDENCE, THIS SET OF DOCUMENTS IS INTENDED TO BE USED FOR DIAGRAMMATIC PURPOSED ONLY. UNLESS NOTED OTHERWISE THE GENERAL CONTRACTORS SCOPE OF WORK SHALL INCLUDE FURNISHING ALL MATERIALS, EQUIPMENT, LABOR AND ANY REQUIREMENTS DEEMED NECESSARY TO COMPLETE INSTALLATION AS DESCRIBED INTHE DRAWINGS AND OWNERS PROJECT MANUAL 2. THE CONTRACTOR IS RESPONSIBLE FOR ALL DIMENSIONS AND STANDARDIZED DETAILS THAT REQUIRE MODIFICATIONS DUE TO ACTUAL FIELD CONDITIONS AND REQUIREMENTS MUST BE SUBMITTED TO AND APPROVED BY, VOICESTREAM WIRELESS REPRESENTATIVE PRIOR TO START OF WORK 3. PRIOR TO THE SUBMISSION OF BIDS, CONTRACTORS INVOLVED SHALL VISIT THE JOB SITE TO FAMILIARIZE THEMSELVES WITH ALL CONDITIONS AFFECTING THE PROPOSED PROJECT. CONTRACTORS SHALL VISIT THE CONSTRUCTION SITE WITH THE CONSTRUCTION /CONTRACT DOCUMENTS TO VERIFY FIELD CONDITIONS AND CONFIRM THAT THE PROJECT WILL BE ACCOMPLISHED AS SHOWN. PRIOR TO PROCEEDING WITH CONSTRUCTOR, ANY ERRORS, OMISSIONS, OR DISCREPANCIES SHALL BE BROUGHT TO THE ATTENTION OF THE ARCHITECT/ENGINEER VERBALLY AND IN WRITING. 4. THE GENERAL CONTRACTOR SHALL RECEIVE WRITTEN AUTHORIZATION TO PROCEED WITH CONSTRUCTOR PRIOR TO STARTING WORK ON ANY ITEM NOT CLEARLY DEFINED BY THE CONSTRUCTION DRAWINGS/CONTRACT DOCUMENTS. 5 THE CONTRACTOR SHALL SUPERVISE AND DIRECT THE PROJECT DESCRIBED IN THE CONTRACT DOCUMENTS. THE CONTRACTOR SHALL BE SOLELY RESPONSIBLE FOR ALL CONSTRUCTION MEANS, METHODS, TECHNIQUES, SEQUENCES, SAFETY, AND PROCEDURES FOR COORDINATING ALL PORTIONS OF THE WORK UNDER THE CONTRACT. 6 THE CONTRACTOR SHALL INSTALL ALL EQUIPMENT AND MATERIALS ACCORDING TO MANUFACTURER'SNENDORS SPECIFICATIONS UNLESS NOTED OTHERWISE OR WHERE LOCAL CODES OR ORDINANCES TAKE PRECEDENCE. 7 ALL WORK PERFORMED ON THE PROJECT AND MATERIALS INSTALLED SHALL BE IN STRICT ACCORDANCE WITH ALL APPLICABLE CODES REGULATIONS. AND ORDINANCES. CONTRACTOR SHALL GIVE ALL NOTICES AND COMPLY WITH ALL LAWS, ORDINANCES, RULES, REGULATIONS AND LAWFUL ORDERS OF ANY PUBLIC AUTHORITY, MUNICIPAL AND UTILITY COMPANY SPECIFICATIONS, AND LOCAL AND STATE JURISDICTIONAL CODES BEARING ON THE PERFORMANCE OF THE WORK. 8 GENERAL CONTRACTOR SHALL PROVIDE, AT THE PROJECT SITE, A FULL SET OF CONSTRUCTION DOCUMENTS UPDATED WITH THE LATEST REVISIONS INVOLVED WITH THE PROJECT. THIS SET IS A VALID CONTRACT DOCUMENT ONLY IF THE TITLE SHEET IS STAMPED IN RED INK FOR CONSTRUCTION" AND EACH SUCCESSIVE SHEET BEARS THE ARCHITECTS/ENGINEERS SIGNED WET STAMP. 9 THE CONTRACTOR IS RESPONSIBLE FOR ADEQUATELY BRACING AND PROTECTING ALL WORK DURING CONSTRUCTION AGAINST DAMAGE. BREAKAGE. COLLAPSE. ETC. ACCORDING TO APPLICABLE CODES. STANDARDS, AND GOOD CONSTRUCTION PRACTICES. 10. THE CONTRACTOR SHALL MEET ALL OSHA REQUIREMENTS FOR ALL INSTALLATIONS. 11 THE CONTRACTOR SHALL BE RESPONSIBLE FOR ALL DAMAGES TO THE EXISTING CONSTRUCTOR AND REPAIR ALL DAMAGES TO BETTER THAN NEW CONSTRUCTION. THE CONTRACTOR SHALL NOTIFY THE CONSULTANT OF ANY DAMAGE TO 1110 BUILDING SITE OR ANY ADJACENT STRUCTURES AROUND THE PROJECT. THE T- MOBILE REPRESENTATIVE SHALL BE SOLE AND FINAL JUDGE AS TO THE QUALITY OF THE REPAIRED CONSTRUCTOR. ANY ADDITIONAL MODIFICATIONS WHICH MUST BE MADE SHALL BE MADE AT THE CONTRACTORS EXPENSE. 12. WHERE NEW PAVING, CONCRETE SIDEWALKS OR PATHS MEET EXISTING CONSTRUCTION, THE CONTRACTOR SHALL MATCH THE EXISTING PITCH. GRADE. AND ELEVATION SO THE ENTIRE STRUCTURE SHALL HAVE A SMOOTH TRANSITION. 13 THE CONTRACTOR SHALL MODIFY THE EXISTING FLOORS. WALL CEILING, OR OTHER CONSTRUCTION AS REQUIRED TO GAIN ACCESS TO AREAS FOR ALL MECHANICAL PLUMBING, ELECTRICAL OR STRUCTURAL MODIFICATIONS. WHERE THE EXISTING CONSTRUCTION DOORS, PARTITIONS, CEILING, ETC., ARE TO BE REMOVED, MODIFIED, OR REARRANGED OR WHERE THE EXPOSED OR HIDDEN MECHANICAL ELECTRICAL, SYSTEMS ARE ADDED OR MODIFIED, THE GENERAL CONTRACTOR SHALL REPAIR. PATCH AND MATCH ALL EXISTING CONSTRUCTION AND FINISHES OF ALL FLOORS WALLS AND CEILINGS. WHERE CONCRETE MASONRY CONSTRUCTION IS MODIFIED, THE CONTRACTOR SHALL TOOTH IN ALL NEW CONSTRUCTION TO MATCH THE EXISTING BOND. WHERE CONCRETE CONSTRUCTION IS MODIFIED, THE CONTRACTOR SHALL VERIFY THE EXACT DETAILS TO BE USED FOR CONSTRUCTION. ALL WORK SHALL BE COVERED UNDER THE GENERAL CONTRACT. 14 IF CONTRACTOR OR SUBCONTRACTOR FIND R NECESSARY TO DEVIATE FROM ORIGINAL APPROVED PLANS. THEN IT LS THE CONTRACTORS AND THE SUBCONTRACTORS RESPONSIBILITY TO PROVIDE THE CONSULTANT WITH 4 COPIES OF THE PROPOSED CHANGES FOR HIS APPROVAL BEFORE PROCEEDING WITH THE WORK. IN ADDITION THE CONTRACTOR AND SUBCONTRACTORS SHALL BE RESPONSIBLE FOR PROCURING AU. NECESSARY APPROVALS FROM THE BUILDING AUTHORITIES FOR THE PROPOSED CHANGES BEFORE PROCEEDING WITH THE WORK THE CONTRACTOR AND SUBCONTRACTORS SHALL BE RESPONSIBLE FOR PROCURING ALL NECESSARY INSPECTIONS AND APPROVALS FROM BUILDING AUTHORITIES DURING THE EXECUTION OF THE WORK. 15 CONTRACTOR TO PROVIDE A PORTABLE FIRE EXTINGUISHER WITH A RATING OF NOT LESS THAN 2-A OR 2,A108C WITHIN 75 FEET TRAVEL DISTANCE TO ALL PORTIONS OF PROJECT AREA DURING CONSTRUCTOR. 16 THE CONTRACTOR SHALL PERFORM WORK DURING OWNER'S PREFERRED HOURS TO AVOID DISTURBING NORMAL BUSINESS. 17 SEAL ALL PENETRATIONS THROUGH FIRE-RATED AREAS WITH U.L. LISTED OR FIRE MARSHAL APPROVED MATERIALS AS APPLICABLE TO THIS FAC ILITY AND OR PROJECT SITE. 18 CONTRACTOR SHALL BE RESPONSIBLE FOR UTILITY LOCATES, SCHEDULING, COORDINATING SPECIAL AND BUILDING DEPARTMENT INSPECTIONS. 19. CONTRACTOR SHALL BE RESPONSIBLE FOR CONTACTING AND UTILIZING ORIGINAL ROOFING CONTRACTOR AS REQUIRED TO MAINTAIN ANY EXISTING ROOFING WARRANTY. 20 ROUTING OF ALL CONDUITS. CABLES, CABLE TRAYS ETC ARE INDICATED AS PROPOSED LOCATION ONLY. CONFIRM THE EXACT LOCATION AND ROUTING WITH THE ON SIZE T- MOBILE CONSTRUCTOR MANAGER PRIOR TO STARTING WORK. CONCRETE NOTES: 1. ALL CONCRETE WORK SHALL BE IN ACCORDANCE WITH THE ACI 301, ACI 318 AND THE SPECIFICATION CAST-IN-PLACE CONCRETE. 2. ALL CONCRETE SHALL HAVE A MINIMUM COMPRESSIVE STRENGTH OF 2500 PSI AT 28 DAYS UNO. 3. REINFORCING STEEL SHALL CONFORM TO ASTM A 615. GRADE 60, DEFORMED UNLESS NOTED OTHERWISE. WELDED WIRE FABRIC SHALL CONFORM TO ASTM A 185 WELDED STEEL WIRE FABRIC UNLESS NOTED OTHERWISE. SPLICES CLASS "B" AND ALL HOOKS SHALL BE STANDARD UNO. 4 THE FOLLOWING MINIMUM CONCRETE COVER SHALL BE PROVIDED FOR REINFORCING STEEL UNLESS SHOWN OTHERWISE ON DRAWINGS: CONCRETE GIST AGAINST EARTH • 3 IN. CONCRETE EXPOSED TO EARTH OR WEATHER: 46 AND LARGER 21N. #5 AND SMALLER 8 W WF 1121N. 5 A 1& TROWELED RADIUS SHALL BE PROVIDED AT ALL EXPOSED EDGES OF CONCRETE UNO. HOLES TO RECEIVE EXPANSION/WEDGE ANCHORS SHALL BE 1/8 LARGER IN DIAMETER THAN THE ANCHOR BOLT, DOWEL OR ROD AND SHALL CONFORM TO MFR RECOMMENDATION FOR EMBEDMENT DEPTH OR AS SHOWN ON THE DRAWINGS. AVOID CUTTING EXISTING REBAR WHEN DRILLING HOLES IN THE ELEVATED SLAB. 6 INSTALLATION OF CONCRETE EXPANSION/WEDGE ANCHOR SHALL BE PER MANUFACTURER'S WRITTEN RECOMMENDED PROCEDURES. 7 FLOAT SURFACE SHALL BE A SMOOTH FINISH. SURFACE SHALL BE FREE OF ALL OBVIOUS DEPRESSIONS. SURFACE SHALL BE SLOPED AT 28 TO PROMOTE DRAINAGE AWAY FROM EQUIPMENT. SITE WORK NOTES: 1 RUBBISH, STUMPS, DEBRIS, STICKS, STONES AND OTHER REFUSE SHALL BE REMOVED FROM THE SITE AND DISPOSED OF LEGALLY. 2 THE SITE SHALL BE GRADED TO CAUSE SURFACE WATER TO FLOW AWAY FROM THE PCS EQUIPMENT, TOWER AREAS, AND ADJACENT BUILDINGS. 3 NO FILL OR EMBANKMENT MATERIAL SHALL BE PLACED ON FROZEN GROUND. FROZEN MATERIALS, SNOW OR ICE SHALL NOT BE PLACED IN ANY FILL OR EMBANKMENT. 4. THE SUBGRADE SHALL BE COMPACTED AND BROUGHT TOA SMOOTH UNIFORM GRADE PRIOR TO THE CRUSHED STONE APPLICATION. 5 ALL EXISTING ACTIVE SEWER, WATER, GAS, ELECTRIC, AND OTHER UTILITIES WHERE ENCOUNTERED IN THE WORK SHALL BE PROTECTED AT ALL TIMES. AND WHERE REQUIRED FOR THE PROPER EXECUTION OF THE WORK SHALL BE RELOCATED AS DIRECTED BY ENGINEERS. EXTREME CAUTION SHOULD BE USED BY THE CONTRACTOR WHEN EXCAVATING OR PIER DRILLING AROUND OR NEAR UTILITIES. CONTRACTOR SHALL PROVIDE SAFETY TRAINING FOR THE WORKING CREW. 6. ALL EXISTING INACTIVE SEWER, WATER, GAS, ELECTRIC AND OTHER UTILITIES, WHICH INTERFERE WITH THE EXECUTION OF THE WORK, SHALL BE REMOVED AND SHALL BE CAPPED, PLUGGED OR OTHERWISE DISCONTINUED AT POINTS WHICH WILL NOT INTERFERE WITH THE EXECUTION OF THE WORK, SUBJECT TO THE APPROVAL OF ENGINEERING. 7 THE AREAS OF THE CUSTOMERS PROPERTY DISTURBED BY THE WORK AND NOT COVERED BY THE BUILDING. DRIVEWAY OR CRUSHED STONE. SHALL BE GRADED TO A UNIFORM SLOPE. FERTILIZED, SEEDED, AND COVERED WITH MULCH AS SPECIFIED IN 1110 SPECIFICATION LANDSCAPE WORK. 8 BEDDING MATERIAL FOR UTILITY LINES, CULVERTS AND PIPING: CLEAN SAND, MEDIUM TP COARSE, SUB ROUNDED NATURAL RIVER OR BANK SAND, WASHED. FREE OF SILT OR CLAY, LOAM, FRIABLE OR SOLUBLE MATERIALS. AND ORGANIC MATER; GRADED IN ACCORDANCE WITH THE FOLLOWING GRAIN SIZE DISTRIBUTOR: SIEVE SIZE 3/8• NO. 4 MESH NO 8 MESH NO 16 MESH NO 100 MESH NO 200 MESH PERCENT PASSING 100 60.90 0-45 0-25 0-2 0-2 9. BMPS FOR TEMPORARY EROSION/SEDIMENTATION CONTROL SHALL BE IMPLEMENTED PER LOCAL CITY OR COUNTY GUIDELINES AND PER PLAN IF APPUCABLE. ABBREVIATIONS AC AFF AFG AFS ALUM AB L ARCH BITS BLDG BM BOT B.O. BOO BOS CJ C LG CUR CMU COL CONC CONST CONT CTR DIA /0 DT- (E) EA EJ ELEC EL EO EW EXP EXT FD FIN FIN FL8 FL8 FTG GA GALV GYP GB HM HOR HR HT HVAC INSUL INT AIR CONDITIONER ABOVE FINISHED FLOOR ABOVE RNISHED GRADE ABOVE FINISHED SLAB ALUMINUM ANCHOR BOLT ANGLE ARCHITECTURAL BASE TRANSMISSION SYSTEM BUILDING BEAM BOTTOM BOTTOM OF BOTTOM OF CONCRETE BOTTOM OF STEEL CONTROL JOINT CENTER LINE CEILING CLEAR CONCRETE MASONRY UNIT COLUMN CONCRETE CONSTRUCTOR CONTINUOUS CENTER DIAMETER DETAIL EXISTING EACH EXPANSION JOINT ELECTRIC/ELECTRICAL ELEVATION EQUAL EACH WAY EXPANSION EXTERIOR FLOOR DRAIN FINISH FINISH FLOOR FLOOR FOOTING GAUGE GALVANIZED GYPSUM GYPSUM BOARD HOLLOW METAL HORIZONTAL HOUR HEIGHT HEATING VENTILATION AIR CONDITIONING INSULATION INTERIOR LEGENDS & SYMBOLS CHAINLINK FENCE CEDAR FENCE POWER TELCO POWERITELCO OVERHEAD COAX COAX OVERHEAD POWER CENTERLINE REVISION BUG ELEVATION VIEW BUG ELEVATION DETAIL BUG SECTION BUG - X P - T - T/P - OHC OH JT LAM LF MANUF MAX MECH MM MM MIN MISC MPH MTL NIC NOM NTS OC OD OH OPNG OPP (P) PPS PR PSI PSF PT RAD RD REINF REO'D RM WIN SCHED SECT SF SIM SO FT SS STD STL STRUC TEMP THK T.O. TOS TOC TYP LINO VCT VERT W/ WWM X P T T/P OHC 011 *TOP OF ... EL 0' -0" JOINT LAMINATED LINEAL FOOT MANUFACTURER MAXIMUM MECHANICAL MANHOLE MILLIMETER MINIMUM MISCELLANEOUS MILES PER HOUR METAL NOT IN CONTRACT NOMINAL NOT TO SCALE ON CENTER OUTSIDE DIAMETER OVERHEAD OPENING OPPOSITE PROPOSED PERSONAL COMMUNICATION SYSTEM PLATE PAIR POUNDS PER SQUARE INCH POUNDS PER SQUARE FOOT PRESSURE TREATED RADIUS ROOF DRAIN REINFORCED/REINFORCING REQUIRED ROOM RIGHT OF WAY SCHEDULE SECTION SQUARE FOOT SIMILAR SQUARE FOOT STAINLESS STEEL STANDARD STEEL STRUCTURAL TEMPORARY THICK TOP OF TOP OF STEEL TOP OF CONCRETE TYPICAL UNLESS NOTED OTHERWISE VINYL COMPOSITION TILE VERTICAL WITH WELDED WIRE MESH A \ X X P T T T/P 17P OHC OHC - COAX - COAX - COAX -COAX OH OH DETAIL NUMBER SHEET NUMBER DETAIL NUMBER SHEET NUMBER DETAIL NUMBER SHEET NUMBER IlbKegeam• 19807 NORTHCREEK PKWY N BOTHELL, WA 98011 OFFICE (425) 3967600 — PROJECT INFORMATION* MILITARY & 27TH SE3551 C 3118S140THST TUKWILA, WA 98168 ISSUED FOR: C _REVISION HISTORY: No. DATES DEBCRIPTION, B UILDING PERMIT =PLANS PREPARED BY: B . J. THOMAS, P.E. 7607 80TH AVE NE MARYSVILLE, WA 98270 206. 851.1106 C DRAWN BY: - LICENSURE• AAL BJT AM r EQUIPMENT: _DRAWING INFORMATION: VOICESTREAM WIRELESS ANTENNAS COLLOCATED ON AN EXISTING 53' AGL STEEL MONOPOLE WITH BITS EQUIPMENT IN A 8'6- x 16'-0 FENCED HALF VAULT LEASE AREA. DO NOT SCALE DRAWINGS. CONTRACTOR MUST VERIFY ALL DIMENSIONS AND ADVISE CONSULTANTS OF ANY ERRORS AND OMISSIONS. ALL PREVIOUS ISSUES OF THIS DRAWING ARE SUPERSEDED BY THE LATEST REVISION. THE INFORMATION CONTAINED IN THIS SET OF DOCUMENTS IS PROPRIETARY BY NATURE. ANY USE OR DISCLOSURE OTHER THAN WHICH IS RELATED TO NAMED CLIENT IS STRICTLY PROHIBITED. - DRAWING TITLE: DRAWING NUMBER: CHK. APPV. BY: BY: CHK. BY: = APPV. BY:: GENERAL NOTES G -1 B 24 CON RIVERTON PARK UNITED MdlH00i5T CHURCH SIGN ON ROO: 4140 CONCRETE BASE ) I VACATED PORTION PER ORDER DATED JULY 17. 1944 NI L 42. PAGE 381 COMMISSIONERS RECORDS 4• CEgy Y .) (P) 53' HIGH STEEL MONOPOLE W/ OICESTREAM ANTENNAS (TYP OF 3) (P) 8'-6' x 16-0• VOICESTREAM HALF -VAULT TELECOMMUNICATION COMPOUND W/ 6 CHAIN UNK FENCE b PRIVACY SLATS • /,. WI FEN OF P ODN PARCEL NUMBER: LEGAL DESCRIPTION, ROCKERY- ; • 8",.DEC 22x34 SCALE: 1• = 20' 11417 SCALE: 1• = 40' P 6\ _ OVERALL SITE PLAN FF . ONE STORY 4 -' F•A f ! ON WOOD •CONC M f BOO FND STOP AHEAD 9GN PFDE51. /AN — \ SIGN GED C ' CED 1 CFO Q COAT 61108 o S 89 43 (P) 3 U/G ELECTRICAL CONDUIT 80 LF. ± 8 (P) 2 U/0 TELECOMM CONDUIT 60 LF. t (SEE SHT. A-4 FOR TRENCH DETAILS) POLE SUMS= 9t 9m T9) Al US 9I 9QT Dfa Y (P) (4) 4" U/0 (SEE SHT. A-4 NO GROUND SURVEY WAS PERFORMED FOR THIS PROJECT. BASE MAP DEVELOPED USING TOPOGRAPHIC SURVEY INFORMATION PROVIDED BY PROPERTY OWNER. (E) UTILITY POLE TO 8E UTILIZED FOR POWER 8 TELCO SOURCE 86'9 1/47 1 . C COAX CONDUIT 60 LF. OR TRENCH DETAILS) - STOP SIGN L CED ON EAST 4 .R BENCH MARX NO 2 5E1 PR 56510 0 EDGE ASPHALr :.E CCRND; S. 140M & 33RD 5. LEVA non • 362.80' 19807 NORTNCREEK PKWY N BOTHELL, WA 98011 OFFICE (428) 3987800 PROJECT INFORMATION' MILITARY & 27TH SE3551C 3118 S 140TH ST TUKWILA, WA 98168 ISSUED FOR: _ REVISION HISTORY: No. DATE: DESCRIPTION: BUILDING PERMIT CHK. APPV. BY* BY1 PLANS PREPARED BY: B. J. THOMAS, P.E. 7607 80TH AVE NE MARYSVILLE, WA 98270 206-851-1106 — DRAWN BY: _ LICENSURE• CHK. BYs = APPV. BY: AAL BJT AM - EQUIPMENT: DRAWING INFORMATION: 00 NOT SCALE DRAWINGS. CONTRACTOR MUST VERIFY AU. DIMENSIONS AND ADVISE CONSULTANTS OF ANY ERRORS AND OMISSIONS. AU. PREVIOUS ISSUES OF THIS DRAWING ARE SUPERSEDED BY THE LATEST REVISION. THE INFORMATION CONTAINED IN THIS SET OF DOCUMENTS IS PROPRIETARY BY NATURE. ANY USE OR DISCLOSURE OTHER THAN WHICH LS RELATED TO NAMED CLIENT IS STRICTLY PROHIBITED. DRAWING TITLE- DRAWING NUMBER: VOICESTREAM WIRELESS ANTENNAS COLLOCATED ON AN EXISTING 53' AGL STEEL MONOPOLE WITH BTS EQUIPMENT IN A 8'-6 z T6'-O FENCED HALF VAULT LEASE AREA SITE PLAN A -1 A A 8/152006 ISSUED FOR BUILDING PERMIT BJT MP / " \ 3/132006 MINOR REVISIONS BJT MP / /2 \ 12/29/2005 ISSUED FOR ZONING BJT MP \ \ 12/15/2005 ISSUED DESIGN REVIEW BIT MP B 24 CON RIVERTON PARK UNITED MdlH00i5T CHURCH SIGN ON ROO: 4140 CONCRETE BASE ) I VACATED PORTION PER ORDER DATED JULY 17. 1944 NI L 42. PAGE 381 COMMISSIONERS RECORDS 4• CEgy Y .) (P) 53' HIGH STEEL MONOPOLE W/ OICESTREAM ANTENNAS (TYP OF 3) (P) 8'-6' x 16-0• VOICESTREAM HALF -VAULT TELECOMMUNICATION COMPOUND W/ 6 CHAIN UNK FENCE b PRIVACY SLATS • /,. WI FEN OF P ODN PARCEL NUMBER: LEGAL DESCRIPTION, ROCKERY- ; • 8",.DEC 22x34 SCALE: 1• = 20' 11417 SCALE: 1• = 40' P 6\ _ OVERALL SITE PLAN FF . ONE STORY 4 -' F•A f ! ON WOOD •CONC M f BOO FND STOP AHEAD 9GN PFDE51. /AN — \ SIGN GED C ' CED 1 CFO Q COAT 61108 o S 89 43 (P) 3 U/G ELECTRICAL CONDUIT 80 LF. ± 8 (P) 2 U/0 TELECOMM CONDUIT 60 LF. t (SEE SHT. A-4 FOR TRENCH DETAILS) POLE SUMS= 9t 9m T9) Al US 9I 9QT Dfa Y (P) (4) 4" U/0 (SEE SHT. A-4 NO GROUND SURVEY WAS PERFORMED FOR THIS PROJECT. BASE MAP DEVELOPED USING TOPOGRAPHIC SURVEY INFORMATION PROVIDED BY PROPERTY OWNER. (E) UTILITY POLE TO 8E UTILIZED FOR POWER 8 TELCO SOURCE 86'9 1/47 1 . C COAX CONDUIT 60 LF. OR TRENCH DETAILS) - STOP SIGN L CED ON EAST 4 .R BENCH MARX NO 2 5E1 PR 56510 0 EDGE ASPHALr :.E CCRND; S. 140M & 33RD 5. LEVA non • 362.80' 19807 NORTNCREEK PKWY N BOTHELL, WA 98011 OFFICE (428) 3987800 PROJECT INFORMATION' MILITARY & 27TH SE3551C 3118 S 140TH ST TUKWILA, WA 98168 ISSUED FOR: _ REVISION HISTORY: No. DATE: DESCRIPTION: BUILDING PERMIT CHK. APPV. BY* BY1 PLANS PREPARED BY: B. J. THOMAS, P.E. 7607 80TH AVE NE MARYSVILLE, WA 98270 206-851-1106 — DRAWN BY: _ LICENSURE• CHK. BYs = APPV. BY: AAL BJT AM - EQUIPMENT: DRAWING INFORMATION: 00 NOT SCALE DRAWINGS. CONTRACTOR MUST VERIFY AU. DIMENSIONS AND ADVISE CONSULTANTS OF ANY ERRORS AND OMISSIONS. AU. PREVIOUS ISSUES OF THIS DRAWING ARE SUPERSEDED BY THE LATEST REVISION. THE INFORMATION CONTAINED IN THIS SET OF DOCUMENTS IS PROPRIETARY BY NATURE. ANY USE OR DISCLOSURE OTHER THAN WHICH LS RELATED TO NAMED CLIENT IS STRICTLY PROHIBITED. DRAWING TITLE- DRAWING NUMBER: VOICESTREAM WIRELESS ANTENNAS COLLOCATED ON AN EXISTING 53' AGL STEEL MONOPOLE WITH BTS EQUIPMENT IN A 8'-6 z T6'-O FENCED HALF VAULT LEASE AREA SITE PLAN A -1 (E) BUILDING WALKWAY (E) BUILDING (E) BUILDING WALKWAY 10' 1 s 00018 (E) ROAD (P) 53' HIGH STEEL MONOPOLE WI VOICESTREAM ANTENNAS (TYP OF 3) ' 20 (P) 8'-6" . 16'-0" VOICESTREAM 8' THICK CONC HALF -VAULT TELECOMMUNICATION COMPOUND W/ 6' CHAIN LINK FENCE & PRIVACY SLATS (SEE SHT. A-4, DETAIL 10) W- W- W W W W -X - X- X- X- X- X (P) VOICESTREAM UTILITY N -FRAME 6 THICK CONC WALL (TYP) (E) U/O WATER) I •� E 1 9 / 4 / J I (E) DECIDOUS TREES (E) 6"t CONC WALL (P) 4' WIDE MAN GATE TO REPLACE PORTION OF (E) FENCE (E) PLAYGROUND - • (P) (4) 4' UM PVC COAX CONDUIT 60 LF. t (SEE SHT. A-4 FOR TRENCH DETAILS) (P) 4' WIDE MAN GATE W/ LOCK TO PROVIDE ACCESS INTO VOICESTREAM COMPOUND (P) VOICESTREAM BTS EQUIPMENT (SEE SLAT. A-3 FOR CABINET DETAILS) 360 (P) 3' U/O ELECTRICAL CONDUIT 80 L.F. t d (P) Y U/G TELECOMM CONDUIT 60 LF. t (SEE SHT. A-4 FOR TRENCH DETAILS) ENLARGED SITE PLAN 22x34 SCALE: 3/18' =1' 11x17 SCALE: 3/32= P (E) UTILITY POLE TO BE UTILIZED FOR POWER & TELCO SOURCE IhKeibea!n 19807 NORTHCREEK PKWY N BOTHELL, WA 98011 OFFICE (425) 398.7800 - PROJECT INFORMATION. MILITARY & 27TH SE3551 C 3118S140THST TUKWILA, WA 98168 C - ISSUED FOR: _REVISION HISTORY! B UILDING PERMIT Na DATE] DESCRIPTION] CHK. APPV. BY] DTI =PLANS PREPARED BY: B . J. THOMAS, P.E. 7607 80TH AVE NE MARYSVILLE, WA 98270 206 - 851.1106 DRAWN BY: — LICENSURE CHK. BY: = APPV. BY:. AAL BJT AM EQUIPMENT: D R A WING INFORMATION: DO NOT SCALE DRAWINGS. CONTRACTOR MUST VERIFY ALL DIMENSIONS AND ADVISE CONSULTANTS OF ANY ERRORS AND OMISSIONS. ALL PREVIOUS ISSUES OF THIS DRAWING ARE SUPERSEDED BY THE LATEST REVISION. THE INFORMATION CONTAINED IN THIS SET OF DOCUMENTS IS PROPRIETARY BY NATURE. ANY USE OR DISCLOSURE OTHER THAN WHICH IS RELATED TO NAMED CLIENT IS STRICTLY PROHIBITED. [ DRAWING TITLE: DRAWING NUMBER: VOICESTREAM WIRELESS ANTENNAS COLLOCATED ON AN EXISTING 53' AGL STEEL MONOPOLE WITH BTS EQUIPMENT IN A 6-6* 16'-0 FENCED HALF VAULT LEASE AREA ENLARGED SITE PLAN A -1.1 A 8/15/2008 ISSUED FOR BUILDING PERMIT BJT MP //�\ /3\ 3/13/2008 MINOR REVISIONS BJT MP A 12/292005 ISSUED FOR ZONING BJT MP / 1\ 12/15/2005 ISSUED DESIGN REVIEW BJT MP (E) BUILDING WALKWAY (E) BUILDING (E) BUILDING WALKWAY 10' 1 s 00018 (E) ROAD (P) 53' HIGH STEEL MONOPOLE WI VOICESTREAM ANTENNAS (TYP OF 3) ' 20 (P) 8'-6" . 16'-0" VOICESTREAM 8' THICK CONC HALF -VAULT TELECOMMUNICATION COMPOUND W/ 6' CHAIN LINK FENCE & PRIVACY SLATS (SEE SHT. A-4, DETAIL 10) W- W- W W W W -X - X- X- X- X- X (P) VOICESTREAM UTILITY N -FRAME 6 THICK CONC WALL (TYP) (E) U/O WATER) I •� E 1 9 / 4 / J I (E) DECIDOUS TREES (E) 6"t CONC WALL (P) 4' WIDE MAN GATE TO REPLACE PORTION OF (E) FENCE (E) PLAYGROUND - • (P) (4) 4' UM PVC COAX CONDUIT 60 LF. t (SEE SHT. A-4 FOR TRENCH DETAILS) (P) 4' WIDE MAN GATE W/ LOCK TO PROVIDE ACCESS INTO VOICESTREAM COMPOUND (P) VOICESTREAM BTS EQUIPMENT (SEE SLAT. A-3 FOR CABINET DETAILS) 360 (P) 3' U/O ELECTRICAL CONDUIT 80 L.F. t d (P) Y U/G TELECOMM CONDUIT 60 LF. t (SEE SHT. A-4 FOR TRENCH DETAILS) ENLARGED SITE PLAN 22x34 SCALE: 3/18' =1' 11x17 SCALE: 3/32= P (E) UTILITY POLE TO BE UTILIZED FOR POWER & TELCO SOURCE IhKeibea!n 19807 NORTHCREEK PKWY N BOTHELL, WA 98011 OFFICE (425) 398.7800 - PROJECT INFORMATION. MILITARY & 27TH SE3551 C 3118S140THST TUKWILA, WA 98168 C - ISSUED FOR: _REVISION HISTORY! B UILDING PERMIT Na DATE] DESCRIPTION] CHK. APPV. BY] DTI =PLANS PREPARED BY: B . J. THOMAS, P.E. 7607 80TH AVE NE MARYSVILLE, WA 98270 206 - 851.1106 DRAWN BY: — LICENSURE CHK. BY: = APPV. BY:. AAL BJT AM EQUIPMENT: D R A WING INFORMATION: DO NOT SCALE DRAWINGS. CONTRACTOR MUST VERIFY ALL DIMENSIONS AND ADVISE CONSULTANTS OF ANY ERRORS AND OMISSIONS. ALL PREVIOUS ISSUES OF THIS DRAWING ARE SUPERSEDED BY THE LATEST REVISION. THE INFORMATION CONTAINED IN THIS SET OF DOCUMENTS IS PROPRIETARY BY NATURE. ANY USE OR DISCLOSURE OTHER THAN WHICH IS RELATED TO NAMED CLIENT IS STRICTLY PROHIBITED. [ DRAWING TITLE: DRAWING NUMBER: VOICESTREAM WIRELESS ANTENNAS COLLOCATED ON AN EXISTING 53' AGL STEEL MONOPOLE WITH BTS EQUIPMENT IN A 6-6* 16'-0 FENCED HALF VAULT LEASE AREA ENLARGED SITE PLAN A -1.1 (E) BUILDING RADOME W/ ANTENNAS WITHIN SHROUD (6) 53 HIGH STEEL MONOPOLE PROPOSED GPS ANTENNA ALL COAX AND ELECTRICAL SERVICES TO BE ROUTED INSIDE POLE or II/ I I I TOP OF POLE ad ik 53'-0' AOL IV RAD CENTER idlk 50-0 AGL (E) DECIDOUSTREES \`( oityifr 1, 4 STRUCTURAL NOTE: STRUCTURAL DESIGN OF MONOPOLE BY OTHERS. 1 PAINT NOTE: NON -GLOSSY WHITE 1 TOWER LIGHTING NOTE: FAA LIGHTING NOT REQUIRED. 1 LEASE AREA SOUTH ELEVATION SCALE: NTS GROUND LEVEL 1142 as • 19607 NORTHCREEK PKWY N BOTHELL, WA 98011 OFFICE (425) 398.7800 — PROJECT INFORMATION' MILITARY & 27TH SE3551C 3118S140THST TUKWILA, WA 98168 ISSUED FOR: C _REVISION HISTORY: BUILDING PERMIT Na DATE DESCRIP710113 CHK. APPV. BYi BY, — PLANS PREPARED BY: B. J. THOMAS, P.E. 7607 80TH AVE NE MARYSVILLE, WA 98270 206 - 851.1106 C DRAWN BY: _ LICENSURE' CHK. BY: = APPV. BY:. AAL BJT AM - EQUIPMENT: DRAWING INFORMATION: DO NOT SCALE DRAWINGS. CONTRACTOR MUST VERIFY ALL DIMENSIONS AND ADVISE CONSULTANTS OF ANY ERRORS AND OMISSIONS. AU. PREVIOUS ISSUES OF THIS DRAWING ARE SUPERSEDED BY THE LATEST REVISION. THE INFORMATION CONTAINED IN THIS SET OF DOCUMENTS 15 PROPRIETARY BY NATURE. ANY USE OR DISCLOSURE OTHER THAN WHICH 15 RELATED TO NAMED CLIENT IS STRICTLY PROHIBITED. DRAWING TITLE: SITE ELEVATION DRAWING NUMBER: VOICESTREAM WIRELESS ANTENNAS COLLOCATED ON AN EXISTING 53' AGL STEEL MONOPOLE WITH BTS EQUIPMENT IN A 8' -0' ■ 18-0' FENCED HALF VAULT LEASE AREA. A -2 /� �/4�� 8/15/2036 ISSUED FOR BJT MP BUILDING PERMIT ! ///3��\ 3/132006 MINOR REVISIONS BJT MP / 12/292005 ISSUED FOR ZONING BJT MP / 7 \ 17/152005 ISSUED DESIGN REVIEW BJT MP (E) BUILDING RADOME W/ ANTENNAS WITHIN SHROUD (6) 53 HIGH STEEL MONOPOLE PROPOSED GPS ANTENNA ALL COAX AND ELECTRICAL SERVICES TO BE ROUTED INSIDE POLE or II/ I I I TOP OF POLE ad ik 53'-0' AOL IV RAD CENTER idlk 50-0 AGL (E) DECIDOUSTREES \`( oityifr 1, 4 STRUCTURAL NOTE: STRUCTURAL DESIGN OF MONOPOLE BY OTHERS. 1 PAINT NOTE: NON -GLOSSY WHITE 1 TOWER LIGHTING NOTE: FAA LIGHTING NOT REQUIRED. 1 LEASE AREA SOUTH ELEVATION SCALE: NTS GROUND LEVEL 1142 as • 19607 NORTHCREEK PKWY N BOTHELL, WA 98011 OFFICE (425) 398.7800 — PROJECT INFORMATION' MILITARY & 27TH SE3551C 3118S140THST TUKWILA, WA 98168 ISSUED FOR: C _REVISION HISTORY: BUILDING PERMIT Na DATE DESCRIP710113 CHK. APPV. BYi BY, — PLANS PREPARED BY: B. J. THOMAS, P.E. 7607 80TH AVE NE MARYSVILLE, WA 98270 206 - 851.1106 C DRAWN BY: _ LICENSURE' CHK. BY: = APPV. BY:. AAL BJT AM - EQUIPMENT: DRAWING INFORMATION: DO NOT SCALE DRAWINGS. CONTRACTOR MUST VERIFY ALL DIMENSIONS AND ADVISE CONSULTANTS OF ANY ERRORS AND OMISSIONS. AU. PREVIOUS ISSUES OF THIS DRAWING ARE SUPERSEDED BY THE LATEST REVISION. THE INFORMATION CONTAINED IN THIS SET OF DOCUMENTS 15 PROPRIETARY BY NATURE. ANY USE OR DISCLOSURE OTHER THAN WHICH 15 RELATED TO NAMED CLIENT IS STRICTLY PROHIBITED. DRAWING TITLE: SITE ELEVATION DRAWING NUMBER: VOICESTREAM WIRELESS ANTENNAS COLLOCATED ON AN EXISTING 53' AGL STEEL MONOPOLE WITH BTS EQUIPMENT IN A 8' -0' ■ 18-0' FENCED HALF VAULT LEASE AREA. A -2 EQUIPMENT ISOMETRIC VIEW N.T.S. PURCELL PPC PLINTH - PROVIDE SHIMS TO LEVEL I o o 7a 0 N.T.S. PLINTH ANCHOR 1?X 4-12' REDHEAD SLEEVE ANCHOR (TYP) • (�) 7S NOKIA ULTRASITE CABINET PLINTH (TYP) - PROVIDE SHIMS TO LEVEL 1/7 BTS EQUIPMENT PLINTH DETAIL Ys 0 EQUIPMENT CABINET ELEVATION N.T.S. L L Ys e 1' PURCELL POWER CABINET N.T,S. 2 7s NOKIA ULTRASITE CABINET SERVICE CLEARANCE PLAN 8 Li L L NOKIA ULTRASITE CABINET l J 1 J REQUIRED MINIMUM SERVICE CLEARANCE J 7s- �1 19807 NORTHCREEK PKWY N BOTHELL. WA 98011 OFFICE (425) 898.7600 PROJECT INFORMATION. MILITARY & 27TH SE3551 C 3118 S 140TH ST TUKWILA, WA 98188 ISSUED FOR: BUILDING PERMIT REVISION HISTORY: No. DATE. DESCRIPTION. =PLANS PREPARED BY. C DRAWN BY: _ LICENSURE: CHK. APPV. BY. BY. B. J. THOMAS, P.E. 7607 80TH AVE NE MARYSVILLE, WA 98270 206.851.1106 CHK. BY: = APPV. BY: _ AAL BJT AM EQUIPMENT: DRAWING INFORMATION: DO NOT SCALE DRAWINGS. CONTRACTOR MUST VERIFY ALL DIMENSIONS AND ADVISE CONSULTANTS OF ANY ERRORS AND OMISSIONS. ALL PREVIOUS ISSUES OF THIS DRAWING ARE SUPERSEDED BY THE LATEST REVISION. THE INFORMATION CONTAINED IN THIS SET OF DOCUMENTS IS PROPRIETARY BY NATURE. ANY USE OR DISCLOSURE OTHER THAN WHICH IS RELATED TO NAMED CLIENT IS STRICTLY PROHIBITED. DRAWING TITLE. BTS EQUIPMENT DETAILS DRAWING NUMBER: VOICESTREAM WIRELESS ANTENNAS COLLOCATED ON AN EXISTING 53' AGl STEEL MONOPOLE WITH BTS EQUIPMENT IN A 8 18'0 FENCED HALF VAULT LEASE AREA. A -3 A 8/1 ISSUED FOR BUILDING PERMIT BJT MP /3\ 3/13/2008 MINOR REVISIONS BJT MP //2\\ 1 12/292005 ISSUED FOR ZONING BJT MP /' \ 12/15/2005 ISSUED OESIGN REVIEW BJT MP EQUIPMENT ISOMETRIC VIEW N.T.S. PURCELL PPC PLINTH - PROVIDE SHIMS TO LEVEL I o o 7a 0 N.T.S. PLINTH ANCHOR 1?X 4-12' REDHEAD SLEEVE ANCHOR (TYP) • (�) 7S NOKIA ULTRASITE CABINET PLINTH (TYP) - PROVIDE SHIMS TO LEVEL 1/7 BTS EQUIPMENT PLINTH DETAIL Ys 0 EQUIPMENT CABINET ELEVATION N.T.S. L L Ys e 1' PURCELL POWER CABINET N.T,S. 2 7s NOKIA ULTRASITE CABINET SERVICE CLEARANCE PLAN 8 Li L L NOKIA ULTRASITE CABINET l J 1 J REQUIRED MINIMUM SERVICE CLEARANCE J 7s- �1 19807 NORTHCREEK PKWY N BOTHELL. WA 98011 OFFICE (425) 898.7600 PROJECT INFORMATION. MILITARY & 27TH SE3551 C 3118 S 140TH ST TUKWILA, WA 98188 ISSUED FOR: BUILDING PERMIT REVISION HISTORY: No. DATE. DESCRIPTION. =PLANS PREPARED BY. C DRAWN BY: _ LICENSURE: CHK. APPV. BY. BY. B. J. THOMAS, P.E. 7607 80TH AVE NE MARYSVILLE, WA 98270 206.851.1106 CHK. BY: = APPV. BY: _ AAL BJT AM EQUIPMENT: DRAWING INFORMATION: DO NOT SCALE DRAWINGS. CONTRACTOR MUST VERIFY ALL DIMENSIONS AND ADVISE CONSULTANTS OF ANY ERRORS AND OMISSIONS. ALL PREVIOUS ISSUES OF THIS DRAWING ARE SUPERSEDED BY THE LATEST REVISION. THE INFORMATION CONTAINED IN THIS SET OF DOCUMENTS IS PROPRIETARY BY NATURE. ANY USE OR DISCLOSURE OTHER THAN WHICH IS RELATED TO NAMED CLIENT IS STRICTLY PROHIBITED. DRAWING TITLE. BTS EQUIPMENT DETAILS DRAWING NUMBER: VOICESTREAM WIRELESS ANTENNAS COLLOCATED ON AN EXISTING 53' AGl STEEL MONOPOLE WITH BTS EQUIPMENT IN A 8 18'0 FENCED HALF VAULT LEASE AREA. A -3 6' HIGH GATE/FENCE Ir ISSN OPTS x MICE POSTrso PROW. P NTEml POST TYPE POST DIAMETER FOOTING S VE NOTES: LINE POST 1- 7/8 - 318'0) 170x18'(170x241 D.4 ®b4 D. 4Lroxvo ro. D2.a.4>=DaEO rr . 72.. w- OFlsnx¢R4.mDO. ry D ww . ..a CORNER POST 70(4'0) 170x36• (170x47) GATE POST 70 (4'0) 170x36' (170x47) A ISSUED FOR BUILDING PERMIT BJT MP A 8/15IZ008 /3\ 3/132006 MINOR REVISIONS BJT MP / ` \ 12/29/2005 ISSUED FOR ZONING BJT MP A 12/15/2005 ISSUED DESIGN REVIEW BJT MP 6' HIGH GATE/FENCE Ir ISSN OPTS x MICE POSTrso PROW. P NTEml POST TYPE POST DIAMETER FOOTING S VE NOTES: LINE POST 1- 7/8 - 318'0) 170x18'(170x241 D.4 ®b4 D. 4Lroxvo ro. D2.a.4>=DaEO rr . 72.. w- OFlsnx¢R4.mDO. ry D ww . ..a CORNER POST 70(4'0) 170x36• (170x47) GATE POST 70 (4'0) 170x36' (170x47) 24' MIN. 6 1/7 MIN. ELECTRICAL SERVICE TRENCH N.T.S. I I I II =II I -1I UTILTY WARNING TAPE COAX CABLE TRENCH N.T.S. 200 AMP ELECTRICAL SERVICE PANEL 1.58' UNISTRUT- ATTACH AS REQUIRED TRANSIENT VOLTAGE SURGE SUPPRESSER FINISH GRADE OR AC PAVING MATCH SLOPE THICKNESS OF EXISTING UNDISTURBED NATIVE SOIL COMPACTED BACKFILL PER WSDOT 9.03.14(3) COMPACTED TO MIN UNIT WT AS DETERMINED BY ASTM D1557 PIPE ZONE BEDDING PER WSDOT 9-03.12(3) COMPACTED TO MIN. 95% OF MAX UNIT WT AS DETERMINED BY ASTM D1557 (4) 4'0 PVC COAX CABLE CONDUITS (1) 70 PVC COAX CONTROLLER CABLE CONDUIT WEST SIDE OF COMPOUND e FINISH GRADE OR AC PAVING MATCH SLOPE THICKNESS OF EXISTING UNDISTURBED NATIVE SOIL COMPACTED BACKFILL PER WSDOT 9-03.14(3) COMPACTED TO MIN OF 95% MAX. UNIT WT AS DETERMINED BY ASTM D1557 UTILITY WARNING TAPE DIRECT BURIED Y PVC ELECTRICAL CONDUIT W/38' RADIUS SWEEPS PIPE ZONE BEDDING PER WSDOT 9-03.12(3) COMPACTED TO MIN. 95% OF MAX UNIT WT AS DETERMINED BY ASTM D1557 N.T.S. SERVICE LIGHT WITH TIMER AND DUPLEX RECEPTACLE PLASTIC UNISTRUT ENDCAPS TYPICAL STANDARD 7 0 GALVANIZED STEEL PIPE 24' MIN. 4 4 e 6' CONC. STEMWALL ADJ. HEIGHT AS REOUIRED FOR 6' MIN. ABOVE FINISH GRADE 8• CONCRETE PAD FOR 8T3 EQUIPMENT SHELTER 0 N.T.S. TELCO DEMARCATION POINT 1-5/8 UNISTRUT - ATTACH AS REQUIRED H -FRAME UTILITY EQUIPMENT N.T.S. 6' COMPACTED AGGREGATE TO 95% MAX UNIT WEIGHT PER ASTM D1557 18• MIN. I II II - II I - ,II TELCO SERVICE TRENCH UNDISTURBED NATIVE SOIL 2500 PSI CONCRETE NO SPECIAL INSPECTIONS REQUIRED UTILITY WARNING TAPE EQUIPMENT SHELTER VAULT SECTION EAST SIDE OF COMPOUND FINISH GRADE OR AC PAVING MATCH _ SLOPE THICKNESS OF EXISTING M N. I —I I I =I —1T UNDISTURBED NATIVE SOIL 4 T7 COMPACTED BACKFILL PER WSDOT 9-03.14(3) COMPACTED TO MIN OF 95% MAX. UNIT WT AS DETERMINED BY ASTM D1557 DIRECT BURIED 7 PVC TELEPHONE CONDUIT (2) 8 PAIR DROP. PIPE ZONE BEDDING PER WSDOT 903.12(3) COMPACTED TO MIN. 95% OF MAX UNIT WT AS DETERMINED BY ASTM D1557 4' PERF PIPE W/ DRAIN ROCK TYP. STANDARD 7 0 GALVANIZED STEEL PIPE VOICESTREAM ANTENNAS (SEE SHT. RF -2 FOR DETAILS) NOTE: DIAGRAM REPRESENTS ANTENNA SECTORS ONLY AND MAY NOT ACCURATELY REPRESENT THE ACTUAL POSITIONING OF THE ANTENNAS MOUNTED TO THE POLE. 0 N.T.S. TRUSS OR TENSION ROD AS REQUIRED e ANTENNA COVERAGE SECTORS NOTE: (2) 6' SLIDING GATES DESIGN BY FENCE CONTRACTOR 10' TYPICAL PANEL 8' HIGH N.T.S. e 8 1/7 MIN. SHARED ELECTRICAL AND TELCO TRENCH 4' GATE FENCE DETAIL N.T.S. NOTICE oto�r o bravo] nryTmD�ltMr wdti{ oom000 .. r ` .w-wr- rlrr -OSIL SOAK tia 0 2 MAX N.T.S. PRIVACY SLATS (TYP.) FINISH GRADE OR AC PAVING MATCH SLOPE THICKNESS OF EXISTING UNDISTURBED NATIVE SOIL COMPACTED BACKFILL PER WSDOT 9-03.14(3) COMPACTED TO MIN UNIT WT AS DETERMINED BY ASTM D1557 UTILITY WARNING TAPE DIRECT BURIED 7 PVC TELCO CONDUIT W/38' RADIUS SWEEPS PIPE ZONE BEDDING PER WSDOT % OF 903.12(3) COMPACTED TO MIN. 95 MAX UNIT WT AS DETERMINED BY ASTM D1557 DIRECT BURIED 3' PVC ELECTRICAL CONDUIT W/38' RADIUS SWEEPS II 11� .11. =11 =I IN CASE OF AN EMERGENCY CALL 1- 888. 662.4662 Site No: SE3551C site Name: MILITARY & 27TH NOTICE GB®IAL 9FGRMAT1GN MA WORKING KING IN T1/E ARFA OF ANTENIAS • /Sprawl rMU.a.mre..s ., Ob. p•Gbel alga • Aawa slrawmLm • OWNING dm• dosed:YOdrm ..._leas Ca 14U4l346A2 b Id..aa - SITE SIGNAGE DETAIL NOTE: TAN COLORED PRIVACY SLATS REQUIRED TOP RAIL 1/45c3/4 STRETCHER BAR W/ MUSHROOM BANDS FENCE POST (TYP.); SEE CHART BELOW FOR SIZE CHAIN -LINK FABRIC; TO TOUCH GROUND TENSION WIRE AT BOTTOM OF FABRIC FOOTING W/ 1/7 CROWN; SEE CHART BELOW FOR SIZE & DEPTH FENCE & GATE NOTES: 1 GATE FRAME -1 -7/r OD, TOP & BRACE RAIL -1-18' OD, SCHED40 ASTM -F1083 2. FABRIC 9 GA CORE WIRE SIZE 7 MESH FABRIC; FABRIC TO TOUCH GRAVEL BASE. 3. TIE WIRE: MINIMUM 11 GA. GALVANIZED STEEL 4. BARBED WIRE: NONE REQUIRED 5. GATE LATCH: SWINGING GATE LATCH; VERIFY WITH PROJECT MANAGER. 19807 NORTHCREEK PKWY N BOTHELL, WA 98011 OFFICE 1425) 398.7600 _PROJECT INFORMATION• MILITARY & 27TH SE3551C 3118S14OTHST TUKWILA, WA 98188 ISSUED FOR: _REVISION HISTORY: No. DATED DESCRIPTIOND BUILDING PERMIT = PLANS PREPARED BY: CHK. APPV. 8Y, BY, B. J. THOMAS, P.E. 7607 80TH AVE NE MARYSVILLE, WA 98270 206-851-1106 C DRAWN BY: LICENSURE• CHK. BY: = APPV. BY: AAL BJT AM - EQUIPMENT: DRAWING INFORMATION: DO NOT SCALE DRAWINGS. CONTRACTOR MUST VERIFY ALL DIMENSIONS AND ADVISE CONSULTANTS OF ANY ERRORS AND OMISSIONS. ALL PREVIOUS ISSUES OF THIS DRAWING ARE SUPERSEDED BY THE LATEST REVISION. THE INFORMATION CONTAINED IN THIS SET OF DOCUMENTS IS PROPRIETARY BY NATURE. ANY USE OR DISCLOSURE OTHER THAN WHICH IS RELATED TO NAMED CLIENT S STRICTLY PROHIBITED. DRAWING TITLE* DRAWING NUMBER: VOICESTREAM WIRELESS ANTENNAS COLLOCATED ON AN EXISTING 53' AGL STEEL MONOPOLE WITH BTS EQUIPMENT IN A 8' -0' x 18'-O FENCED HALF VAULT LEASE AREA GENERAL DETAILS A -4 (E) HILLSIDE CONCRETE EQUIPMENT PAD (SEE SHT. A-4, DETAIL 6) • J APPROXIMATE LINE OF (E) HILLSIDE 6' HALF -VAULT SIDE (TYP ON THREE SIDES) / j, iy ; '/ -/, •� /,;\/ %��, // , / -/' ;; • �`% / . /i. / '/ / / • • j e HALF -VAULT SECTION 24' 38' SCALE 12'=1' 11'x17 SCALE 1/4' =1' a r 4' FLAG NOTES: • P \<.. Y './</'{K ' /\%'',/\ � \ / � . < ' ' • ALL REINFORCEMENT BARS ( REBAR) SHALL BE SIZED 65 UNLESS NOTED OTHERWISE. HORIZONTAL REBAR SPACING WITHIN HALF -VAULT SIDE SHALL BE 17O.C. VERTICAL REBAR SPACING WITHIN HALF -VAULT SIDE SHALL BE 17O.C. O HALF -VAULT SIDE VIEW (EAST) 24' x 36' SCALE 12' =1' 11' x 17 SCALE: 1/4' = 1' 0 ' 2' 4' ; f \ FILTER FABRIC 4' PERFORATED DRAIN PIPE -DAYLIGHT EACH SIDE WASHED DRAIN ROCK 6' 0 HALF -VAULT PLAN VIEW 24' x 36' SCALE: 12' = 1' 11' x 17 SCALE: 1/4' =1' 0' 2' 4' (P) CONC PAD 16' (P) CONC PAD 16' A TOP OF SLAB A.G 0-0 A. 4 /. y / iii:/ � V \ /. / /!i !r� ✓ �i • A5 O HALF -VAULT FRONT VIEW (NORTH) 24' x 36' SCALE: 12' = 1' 11' x 17 SCALE: 1/4' = 1' o r 4' (E) GRADE LEVEL Voicealeam 19807 NORTHCREEK PKWY N BOTHELL, WA 98011 OFFICE (425) 398 -7800 _PROJECT INFORMATION' MILITARY & 27TH SE3551C 3118 S 140Th ST TUKWILA, WA 98188 C - ISSUED FOR: _REVISION HISTORY: B UILDING PERMIT Na DATE: DESCRIPTION, C DRAWN BY: — LICENSURE- AAL CHK. APPV. BY' BYt — PLANS PREPARED BY: B . J. THOMAS, P.E. 7607 80TH AVE NE MARYSVILLE, WA 98270 206-851-1106 CHK. BY: = APPV. BY: : BJT AM - EQUIPMENT: DRAWING INFORMATION: DO NOT SCALE DRAWINGS. CONTRACTOR MUST VERIFY ALL DIMENSIONS AND ADVISE CONSULTANTS OF ANY ERRORS AND OMISSIONS. ALL PREVIOUS ISSUES OF THIS DRAWING ARE SUPERSEDED BY THE LATEST REVISION. THE INFORMATION CONTAINED IN THIS SET OF DOCUMENTS IS PROPRIETARY BY NATURE. ANY USE OR DISCLOSURE OTHER THAN WHICH IS RELATED TO NAMED CLIENT IS STRICTLY PROHIBITED. DRAWING TITLE: HALF VAULT DETAILS DRAWING NUMBER: VOICESTREAM WIRELESS ANTENNAS COLLOCATED ON AN EXISTING 53' AGL STEEL MONOPOLE WITH BTS EQUIPMENT IN A 6$ x 16-0' FENCED HALF VAULT LEASE AREA. A -5 A 8/15/2006 ISSUED FOR BUILDING PERMIT BJT MP / 4 //3�\ 3/13/2006 MINOR REVISIONS BJT MP / \ 12/29/2005 ISSUED FOR ZONING BJT MP /' \ 12/15/2005 ISSUED DESIGN REVIEW BJT MP (E) HILLSIDE CONCRETE EQUIPMENT PAD (SEE SHT. A-4, DETAIL 6) • J APPROXIMATE LINE OF (E) HILLSIDE 6' HALF -VAULT SIDE (TYP ON THREE SIDES) / j, iy ; '/ -/, •� /,;\/ %��, // , / -/' ;; • �`% / . /i. / '/ / / • • j e HALF -VAULT SECTION 24' 38' SCALE 12'=1' 11'x17 SCALE 1/4' =1' a r 4' FLAG NOTES: • P \<.. Y './</'{K ' /\%'',/\ � \ / � . < ' ' • ALL REINFORCEMENT BARS ( REBAR) SHALL BE SIZED 65 UNLESS NOTED OTHERWISE. HORIZONTAL REBAR SPACING WITHIN HALF -VAULT SIDE SHALL BE 17O.C. VERTICAL REBAR SPACING WITHIN HALF -VAULT SIDE SHALL BE 17O.C. O HALF -VAULT SIDE VIEW (EAST) 24' x 36' SCALE 12' =1' 11' x 17 SCALE: 1/4' = 1' 0 ' 2' 4' ; f \ FILTER FABRIC 4' PERFORATED DRAIN PIPE -DAYLIGHT EACH SIDE WASHED DRAIN ROCK 6' 0 HALF -VAULT PLAN VIEW 24' x 36' SCALE: 12' = 1' 11' x 17 SCALE: 1/4' =1' 0' 2' 4' (P) CONC PAD 16' (P) CONC PAD 16' A TOP OF SLAB A.G 0-0 A. 4 /. y / iii:/ � V \ /. / /!i !r� ✓ �i • A5 O HALF -VAULT FRONT VIEW (NORTH) 24' x 36' SCALE: 12' = 1' 11' x 17 SCALE: 1/4' = 1' o r 4' (E) GRADE LEVEL Voicealeam 19807 NORTHCREEK PKWY N BOTHELL, WA 98011 OFFICE (425) 398 -7800 _PROJECT INFORMATION' MILITARY & 27TH SE3551C 3118 S 140Th ST TUKWILA, WA 98188 C - ISSUED FOR: _REVISION HISTORY: B UILDING PERMIT Na DATE: DESCRIPTION, C DRAWN BY: — LICENSURE- AAL CHK. APPV. BY' BYt — PLANS PREPARED BY: B . J. THOMAS, P.E. 7607 80TH AVE NE MARYSVILLE, WA 98270 206-851-1106 CHK. BY: = APPV. BY: : BJT AM - EQUIPMENT: DRAWING INFORMATION: DO NOT SCALE DRAWINGS. CONTRACTOR MUST VERIFY ALL DIMENSIONS AND ADVISE CONSULTANTS OF ANY ERRORS AND OMISSIONS. ALL PREVIOUS ISSUES OF THIS DRAWING ARE SUPERSEDED BY THE LATEST REVISION. THE INFORMATION CONTAINED IN THIS SET OF DOCUMENTS IS PROPRIETARY BY NATURE. ANY USE OR DISCLOSURE OTHER THAN WHICH IS RELATED TO NAMED CLIENT IS STRICTLY PROHIBITED. DRAWING TITLE: HALF VAULT DETAILS DRAWING NUMBER: VOICESTREAM WIRELESS ANTENNAS COLLOCATED ON AN EXISTING 53' AGL STEEL MONOPOLE WITH BTS EQUIPMENT IN A 6$ x 16-0' FENCED HALF VAULT LEASE AREA. A -5 APPROXIMATE LINE OF (E) HILLSIDE FACE OF (E) HILLSIDE (P) 6' HIGH CHAIN LANK FENCE W/ TAN PRIVACY SLATS As O HALF -VAULT SECTION 24'x36 SCALE 12' = 11' x 1? SCALE 1/4' = 1' 0' Y 4' (P) 4' WIDE MAN GATE TO PROVIDE ACCESS INTO VOICESTREAM COMPOUND (P) 6 HIGH CHAIN UNK FENCE (P) 4' WIDE MAN GATE WI TAN PRIVACY SLATS (E) CHAIN LINK FENCE m O m (E) CHAIN LINK FENCE _ __ I' 1' 'I' 'I' 'I' 'I' 'I' -1' 'I' - 1' 'I' - :•�������������������:�1 ����� ���Ni �������������_. I yr `Ir `Ir `I, `Ir `1 'Ir `I 's ® cliFfriir4V4 / i t / - I - I VOICESTREAM COMPOUND (NORTH SIDE) 24'x 36" SCALE: 12' =1' IPx 1T - SCALE: 1I4' =1' 0 ' 2' 4' — / \ 1 `\ \ \\-117. \ J vI ►JJ�'��d,�vJ'JJ.l�t,'���'�g \ ' I4 !fir ♦��i0IJ4if � �,��t��'►t♦ \ i \ ��;•I I� J J .�4( �I%J�:�Ij / \ \ / I \ \ \ / 1 \ / — \ \ / \ \/ I \ \ / yd \ _\ / — I \ \ / _ \ / .. \ /\ \ j 1 \ _ / \ \ / - / \ / A-5 O PERSPECTIVE VIEW 24' x 36' SCALE, NTS 11' x 17' SCALE NTS \ / / \ - I / — / / i I I / / / / y4 I 44 �II�'i►� > v, / I / / I / / 1 \ / \ \ / • / I \ / / 1 \ / / 1 \ / \ / \ j \\ / \ % \ \ \ \ / — \\ / —\ / — \\ / — / -- I �►i\ 1 � / \ \ / f \ / \ / I \ \ / I / \ . \\! I , \ - I '' FENCE NOTE: TAN PRIVACY SLATS REQUIRED FOR THIS PROJECT. PRIVACY SLATS NOT SHOWN FOR CLARITY. 1 PROJECT INFORMATION: MILITARY & 27TH SE3551C 3118 S 140TH ST TUKWILA, WA 98168 ISSUED FOR: 19807 NORTHCREEK PKWY N BOTHELL. WA 98011 OFFICE (446) 398-7600 - REVISION HISTORY: BUILDING PERMIT No. DATE: DESCRIPTION: =PLANS PREPARED BY: ( =DRAWN BY: LICENSURE: - EQUIPMENT: DRAWING INFORMATION: DRAWING TITLE: DRAWING NUMBER: CHK. APPV. BY: BY: / 1 , \ A ' 1 8/15/2006 3/132006 12/292005 12/15/2005 ISSUED FOR BUILDING PERMIT MINOR REVISIONS ISSUED FOR ZONING ISSUED DESIGN REVIEW BJT BJT BJT BJT MP MP MP MP B. J. THOMAS, P.E. 7607 80TH AVE NE MARYSVILLE, WA 98270 206-851-1106 CHK. BY: = APPV. BY: _ AAL BJT AM VOICESTREAM WIRELESS ANTENNAS COLLOCATED ON AN EXISTING 53' AGL STEEL MONOPOLE WITH BTS EQUIPMENT IN A 64' x 16'4' FENCED HALF VAULT LEASE AREA. DO NOT SCALE DRAWINGS. CONTRACTOR MUST VERIFY ALL DIMENSIONS AND ADVISE CONSULTANTS OF ANY ERRORS AND OMISSIONS. ALL PREVIOUS ISSUES OF THIS DRAWING ARE SUPERSEDED BY THE LATEST REVISION. T115 INFORMATION CONTAINED IN THIS SET OF DOCUMENTS 6 PROPRIETARY BY NATURE. ANY USE OR DISCLOSURE OTHER THAN WHICH IS RELATED TO NAMED CLIENT IS STRICTLY PROHIBITED. HALF VAULT ELEVATIONS A -5.1 X I , _ — P — P — P — P— p7.— P— P P I— C 1 a J '0 C O Xl I f f 1l,. I I X I r e NOKIA NOKIA I /I` ULTRASITE ULTRASITE O O SITE SUPPORT ' I 8/152006 p.000b ? - X X - X X X - X- X- -_ r- P .9 L UTILITY SERVICE H -FRAME AND EQUIPMENT (SEE SHT. A -5, DETAIL 9) -, P — P — P — (P) (4) 4- U/0 PVC COAX CONDUIT 60 LF. t 8 (P) r U/0 PVC CONTROLLER CABLE 60 LF. t (SEE SHT. A-1.1 FOR ROUTING INFO) (P) r U/0 PVC CONTROLLER CABLE TO BE ROUTED W/ COAX CONDUIT P — P — P ▪ P P / PANEL SCHEDULE CIRCUIT DESCRIPTION PURCELL TVSS 60 A B CIRCUIT DESCRIPTION 20 • 0 — RECEPTACLE 20 LIGHT 0— / 0 / - P — P — P _ T P ti X — X — X x J ELECTRICAL SITE PLAN 22,34 SCALE: 12' = 1' 11,17 SCALE: 1/4' = 1• UTILITY SERVICE 11-FRAME AND EQUIPMENT (SEE SHT. A -5, DETAIL 9) (P) 1' U/G PVC FOR TELCO BTS (P) 1' U/G PVC CONDUIT WI (3) #8 THWN 6 (1) 08 GROUND TO BTS T (P) Y U/G PVC ELECTRICAL CONDUIT & (P) r U/0 PVC TELECOMM CONDUIT TO U IUTY POLE (SEE SHT. A -1.1 FOR ROUTING INFO) 2.12 PVC FROM UTILITY SOURCE (3) 03/0 THWN IN r CONDUIT ELECTRICAL NOTES: 1 ALL ELECTRICAL WORK SHALL BE COMPLETED IN ACCORDANCE WITH THE LATEST EDITION OF THE NATIONAL ELECTRICAL CODE AND ANY LOCAL, CITY OR COUNTY CODES THAT MAY APPLY. 2. GROUNDING SHALL COMPLY WITH ARTICLE 250 OF THE NATIONAL ELECTRICAL CODE. 3. CONTRACTOR RESPONSIBLE FOR PERMITTING, FILINGS, INSPECTIONS AND TESTING AS REQUIRED BY THE PERMITTING AUTHORITY AND VOICESTREAM WIRELESS. 4 UNDERGROUND CONDUIT SHALL BE RIGID POLYVINYL CHLORIDE CONDUIT, SCHEDULE 40, TYPE 1, CONFORMING TO UL ARTICLE 651, MANUFACTURED BY WESTERN PLASTICS OR CARLON. ALL BENDS SHALL BE 30' MINIMUM RADIUS. 5 CONTRACTOR SHALL CONTACT ALL UTILITIES FOR LOCATION OF UNDERGROUND SERVICES. SERVICE LOCATIONS TO BE CONFIRMED PRIOR TO CONSTRUCTION. 6 ALL EQUIPMENT, WIRING, AND MATERIALS MUST HAVE A UL LABEL 7 CONTRACTOR SHALL PROVIDE AND INSTALL A r PVC CONDUIT WITH PULL ROPE FROM THE TELCO LINE BOX AND THE TELCO DEMARCATION POINT. 8 CONTRACTOR SHALL PROVIDE AND INSTALL A 2-1/r PVC CONDUIT FROM PSE SERVICE/DEMARCATION POINT AND METER BASE OR SERVICE PANEL WHERE APPLICABLE. 9 CONDUIT USED INDOORS SHALL BE EMT AND RMC FOR OUTDOORS. COUPUNGS SHALL BE RIGID STEEL AND COMPRESSION TYPE FOR EMT (SET SCREW FITTINGS ARE NOT PERMITTED). FOR ALL STUB -UPS, USE RMC. 10. WIRES AND CABLES SHALL BE CONTINUOUS FROM TERMINATION TO TERMINATION WITH NO SPLICES ALLOWED. 11. ALL JUNCTION AND OUTLET BOXES SHALL BE LABELED WITH KROY TAPE DR EQUAL DESIGNATING ALL CIRCUIT NUMBERS CONTAINED IN EACH BOX 12. THE DISTRIBUTION PANEL SHALL HAVE A TYPED LEGEND IDENTIFING THE LOADS AF ALL CIRCUIT BREAKERS. 13. CONTRACTOR TO INSTALL CONDUIT SEALING COMPOUND, BLACKBURN DX DUCT SEAL OR EQUAL, FOR ALL CONDUITS AFTER WIRING IS PULLED AND TERMINATED. ELECTRICAL DISTRIBUTION PANEL'PP1• 1002 GROUND PER NEC 1/r RMC WITH (2) 012 AND (1) #12 GND 3/4' RMC WITH (5) #10 V CHASE NIPPLE (3)06 AND (1)#8GND 12' RMC WITH (2) 012 AND (1) #12 GND ELECTRICAL BLOCK DIAGRAM 100A, 120/240V, 10, 3W ELECTRICAL DISTRIBUTION PANEL SPACE 0/1 DUPLEX GFI RECEPTACLE WITH WEATHERPROOF COVER TVSS (TRANSEND 50) FURNISHED BY VOICESTREAM ► PURCELL CABINET LIGHT ELECTRICAL ONE LINE LIGHT PPC TVSS GFCI RECEPT. lkicegar NORTHCREEK PKWY 11 BOTHELL, WA 08011 OFFICE (425) 798.7600 _PROJECT INFORMATION. MILITARY & 27TH SEMI 3116 S 140TH ST TUKWILA. WA 98188 ISSUED FOR: C — REVISION HISTORY: No. DATE: DESCRIPTION: B UILDING PERMIT =PLANS PREPARED BY: CHK. APPV. BY: BY: B . J. THOMAS, P.E. 7607 80TH AVE NE MARYSVILLE, WA 98270 206-851-1106 C DRAWN BY: _ LICENSURE' CHK. BY :=APPV. BY:= AAL BJT AM — EQUIPMENT: DRAWING INFORMATION: DO NOT SCALE DRAWINGS. CONTRACTOR MUST VERIFY ALL DIMENSIONS AND ADVISE CONSULTANTS OF ANY ERRORS AND OMISSIONS. ALL PREVIOUS ISSUES OF THIS DRAWING ARE SUPERSEDED BY THE LATEST REVISION. THE INFORMATION CONTAINED IN THIS SET OF DOCUMENTS IS PROPRIETARY BY NATURE. ANY USE OR DISCLOSURE OTHER THAN WHICH IS RELATED TO NAMED CLIENT IS STRICTLY PROHIBITED. DRAWING TITLE' ELECTRICAL SITE PLAN DRAWING NUMBER: VOICESTREAM WIRELESS ANTENNAS COLLOCATED ON AN EXISTING 53' AGL STEEL MONOPOLE WITH FITS EQUIPMENT IN A 8'8' , 16'0" FENCED HALF VAULT LEASE AREA E -1 8/152006 ISSUED FOR BUILDING PERMIT BJT MP //�4 / ' \ 3/13/2006 MINOR REVISIONS BJT MP /2\ 12/292005 ISSUED FOR ZONING BJT MP A 12/15/2005 ISSUED DESIGN REVIEW BJT MP P .9 L UTILITY SERVICE H -FRAME AND EQUIPMENT (SEE SHT. A -5, DETAIL 9) -, P — P — P — (P) (4) 4- U/0 PVC COAX CONDUIT 60 LF. t 8 (P) r U/0 PVC CONTROLLER CABLE 60 LF. t (SEE SHT. A-1.1 FOR ROUTING INFO) (P) r U/0 PVC CONTROLLER CABLE TO BE ROUTED W/ COAX CONDUIT P — P — P ▪ P P / PANEL SCHEDULE CIRCUIT DESCRIPTION PURCELL TVSS 60 A B CIRCUIT DESCRIPTION 20 • 0 — RECEPTACLE 20 LIGHT 0— / 0 / - P — P — P _ T P ti X — X — X x J ELECTRICAL SITE PLAN 22,34 SCALE: 12' = 1' 11,17 SCALE: 1/4' = 1• UTILITY SERVICE 11-FRAME AND EQUIPMENT (SEE SHT. A -5, DETAIL 9) (P) 1' U/G PVC FOR TELCO BTS (P) 1' U/G PVC CONDUIT WI (3) #8 THWN 6 (1) 08 GROUND TO BTS T (P) Y U/G PVC ELECTRICAL CONDUIT & (P) r U/0 PVC TELECOMM CONDUIT TO U IUTY POLE (SEE SHT. A -1.1 FOR ROUTING INFO) 2.12 PVC FROM UTILITY SOURCE (3) 03/0 THWN IN r CONDUIT ELECTRICAL NOTES: 1 ALL ELECTRICAL WORK SHALL BE COMPLETED IN ACCORDANCE WITH THE LATEST EDITION OF THE NATIONAL ELECTRICAL CODE AND ANY LOCAL, CITY OR COUNTY CODES THAT MAY APPLY. 2. GROUNDING SHALL COMPLY WITH ARTICLE 250 OF THE NATIONAL ELECTRICAL CODE. 3. CONTRACTOR RESPONSIBLE FOR PERMITTING, FILINGS, INSPECTIONS AND TESTING AS REQUIRED BY THE PERMITTING AUTHORITY AND VOICESTREAM WIRELESS. 4 UNDERGROUND CONDUIT SHALL BE RIGID POLYVINYL CHLORIDE CONDUIT, SCHEDULE 40, TYPE 1, CONFORMING TO UL ARTICLE 651, MANUFACTURED BY WESTERN PLASTICS OR CARLON. ALL BENDS SHALL BE 30' MINIMUM RADIUS. 5 CONTRACTOR SHALL CONTACT ALL UTILITIES FOR LOCATION OF UNDERGROUND SERVICES. SERVICE LOCATIONS TO BE CONFIRMED PRIOR TO CONSTRUCTION. 6 ALL EQUIPMENT, WIRING, AND MATERIALS MUST HAVE A UL LABEL 7 CONTRACTOR SHALL PROVIDE AND INSTALL A r PVC CONDUIT WITH PULL ROPE FROM THE TELCO LINE BOX AND THE TELCO DEMARCATION POINT. 8 CONTRACTOR SHALL PROVIDE AND INSTALL A 2-1/r PVC CONDUIT FROM PSE SERVICE/DEMARCATION POINT AND METER BASE OR SERVICE PANEL WHERE APPLICABLE. 9 CONDUIT USED INDOORS SHALL BE EMT AND RMC FOR OUTDOORS. COUPUNGS SHALL BE RIGID STEEL AND COMPRESSION TYPE FOR EMT (SET SCREW FITTINGS ARE NOT PERMITTED). FOR ALL STUB -UPS, USE RMC. 10. WIRES AND CABLES SHALL BE CONTINUOUS FROM TERMINATION TO TERMINATION WITH NO SPLICES ALLOWED. 11. ALL JUNCTION AND OUTLET BOXES SHALL BE LABELED WITH KROY TAPE DR EQUAL DESIGNATING ALL CIRCUIT NUMBERS CONTAINED IN EACH BOX 12. THE DISTRIBUTION PANEL SHALL HAVE A TYPED LEGEND IDENTIFING THE LOADS AF ALL CIRCUIT BREAKERS. 13. CONTRACTOR TO INSTALL CONDUIT SEALING COMPOUND, BLACKBURN DX DUCT SEAL OR EQUAL, FOR ALL CONDUITS AFTER WIRING IS PULLED AND TERMINATED. ELECTRICAL DISTRIBUTION PANEL'PP1• 1002 GROUND PER NEC 1/r RMC WITH (2) 012 AND (1) #12 GND 3/4' RMC WITH (5) #10 V CHASE NIPPLE (3)06 AND (1)#8GND 12' RMC WITH (2) 012 AND (1) #12 GND ELECTRICAL BLOCK DIAGRAM 100A, 120/240V, 10, 3W ELECTRICAL DISTRIBUTION PANEL SPACE 0/1 DUPLEX GFI RECEPTACLE WITH WEATHERPROOF COVER TVSS (TRANSEND 50) FURNISHED BY VOICESTREAM ► PURCELL CABINET LIGHT ELECTRICAL ONE LINE LIGHT PPC TVSS GFCI RECEPT. lkicegar NORTHCREEK PKWY 11 BOTHELL, WA 08011 OFFICE (425) 798.7600 _PROJECT INFORMATION. MILITARY & 27TH SEMI 3116 S 140TH ST TUKWILA. WA 98188 ISSUED FOR: C — REVISION HISTORY: No. DATE: DESCRIPTION: B UILDING PERMIT =PLANS PREPARED BY: CHK. APPV. BY: BY: B . J. THOMAS, P.E. 7607 80TH AVE NE MARYSVILLE, WA 98270 206-851-1106 C DRAWN BY: _ LICENSURE' CHK. BY :=APPV. BY:= AAL BJT AM — EQUIPMENT: DRAWING INFORMATION: DO NOT SCALE DRAWINGS. CONTRACTOR MUST VERIFY ALL DIMENSIONS AND ADVISE CONSULTANTS OF ANY ERRORS AND OMISSIONS. ALL PREVIOUS ISSUES OF THIS DRAWING ARE SUPERSEDED BY THE LATEST REVISION. THE INFORMATION CONTAINED IN THIS SET OF DOCUMENTS IS PROPRIETARY BY NATURE. ANY USE OR DISCLOSURE OTHER THAN WHICH IS RELATED TO NAMED CLIENT IS STRICTLY PROHIBITED. DRAWING TITLE' ELECTRICAL SITE PLAN DRAWING NUMBER: VOICESTREAM WIRELESS ANTENNAS COLLOCATED ON AN EXISTING 53' AGL STEEL MONOPOLE WITH FITS EQUIPMENT IN A 8'8' , 16'0" FENCED HALF VAULT LEASE AREA E -1 I I I fr Vi 19807 NORTHCREEK PKWY N BOTHELL, WA 98011 OFFICE (423) 398.7600 C . PROJECT INFORMATION' MILITARY 8: 27TH SE3551C 3118 S 140TH ST TUKWILA, WA 98188 - ISSUED FOR: C BUILDING PERMIT _REVISION HISTORY: No. DATE, DESCRIPTION. CHK. APPV. 8Y. BY, 00000 GB r - A 8/152006 I SS BUILDING UED FOR PERMIT BJT MP //� / - \ 3/132008 MINOR REVISIONS BJT MP A \ 12292005 ISSUED FOR ZONING BJT MP /' \ 12/15/2005 ISSUED DESIGN REVIEW BJT MP =PLANS PREPARED BY: B. J. THOMAS, P.E. 7607 80TH AVE NE MARYSVILLE, WA 98270 206. 851.1106 DRAW BY: CHIC. BY: = APPV. BY: AAL C BJT AM LICENSURE' 1 THOJI ' OF 1SF _ �+ 171141 •J -. EKPIRFS 08 25m — EQUIPMENT: VOICESTREAM WIRELESS ANTENNAS COLLOCATED ON AN EXISTING 53' AGL STEEL MONOPOLE WITH BTS EQUIPMENT IN A 8'-0' x 16'-0' FENCED HALF VAULT LEASE AREA INFORMATION: _DRAWING DO NOT SCALE DRAWINGS. CONTRACTOR MUST VERIFY ALL DIMENSIONS AND ADVISE CONSULTANTS OF ANY ERRORS AND OMISSIONS. ALL PREVIOUS ISSUES OF THIS DRAWING ARE SUPERSEDED BY THE LATEST REVISION. THE INFORMATION CONTAINED IN THIS SET OF DOCUMENTS LS PROPRIETARY BY NATURE. ANY USE OR DISCLOSURE OTHER THAN WHICH IS RELATED TO NAMED CLIENT IS STRICTLY PROHIBITED = DRAWING TITLE: GROUNDING PLAN = DRAWING NUMBER: E -2 I I I C . — pP J - -� r_.._ r____ 1 1 00000 GB r - (3) GROUND RODS AROUND MONOPOLE BOND MONOPOLE TO GROUND RING / /' MGB / AGB ( • BOND H -FRAME POSTS AND MOUNTED EQUIPMENT TO GROUND RING / BOND AGB TO MGB GROUND INSPECTION WELL (SEE SHT. E-4, DETAIL 4) GROUND ROD (TYP) (SEE GROUNDING NOTE 7 ) TYPICAL CADWELD BOND (SEE GROUNDING NOTE ) (SEE SHT. E-4 FOR ADDITIONAL INFORMATION )— M BOND G8 TO POLE GROUND RING IN (2) PLACES MOB AT BOTTOM OF POLE BELOW CABLE ENTRANCE PORT AGB AT TOP OF POLE DIRECTLY BELOW ANTENNA ARRAY BOND MONOPOLE GROUND RING TO COMPOUND RING 401* O SITE GROUNDING PLAN E2 22,124 SCALE: 3/8' =,• 11X17 SCALE, 3/18' =1• BOND GATE POST TO GROUND RING & BOND GATE POST TO GATE (GROUND CONNECTIONS PER SHT. E -3, DETAIL 2) (TYP) SEE GROUNDING NOTE 5 (TYP ALL GROUND BARS) BOND H -FRAME POSTS AND MOUNTED EQUIPMENT TO GROUND RING MECHANICAL CONNECTION (TYP) (SEE GROUNDING NOTES 4 AND 8 ) BOND BTS EQUIPMENT TO MGB 92 GREEN STRANDED THWN (TYP) (SEE SHT. E-4. DETAIL 5) BOND (4) CORNER FENCE POST TO SITE GROUND RING (SEE SHT. E -3, DETAIL 2) MGB 62 ON ICE BRIDGE NEAR BTS EQUIPMENT GROUNDING NOTES 1. GROUNDING SHALL COMPLY WITH LATEST EDITION OF THE NATIONAL ELECTRICAL CODE (NEC). 2. MINIMUM BENDING RADIUS FOR A GROUNDING CONDUCTOR IS W. 3. NO SPUCES SHALL BE PERMITTED IN GROUND CONDUCTORS. 4. ALL GROUNDING CONNECTORS ARE TO BE CLEAN AND FREE OF PAINT AND DEBRIS AT THEIR BONDING SURFACES, AND INSTALLED PER MANUFACTURERS RECOMMENDATIONS. USE PENETROX OR EQUIVALENT ANTIOXIDANT GREASE. 5. ALL GROUND BAR CONNECTIONS ARE TO BE 2 HOLE LUG COMPRESSION TYPE. STACKED CONNECTIONS ARE NOT ACCEPTABLE. BACK TO BACK CONNECTIONS ON OPPOSITE SIDES OF THE GROUND BAR ARE PERMITTED. 8. ALL MECHANICAL CONNECTORS SHALL BE TORQUED TO THE MANUFACTURERS SPECIFIED VALUES. 7. MULTIPLE BONDS ON GROUND RODS TO BE SEPARATED BY A MINIMUM OF 5'. 8. MAXIMUM RESISTANCE (TO EARTH) OF THE COMPLETED GROUNDING SYSTEM SHALL NOT EXCEED 5 OHMS. REFER TO GROUNDING NOTE 12 FOR TESTING REQUIREMENTS. 9. TO PREVENT ESTABLISHING A'CHOKE' POINT, GROUND WIRES SHALL NOT BE ROUTED THROUGH HOLES IN ANY METAL OBJECTS OR SUPPORTS. 10. GROUND BARS SHALL NOT BE FIELD MODIFIED. 11. GROUND RING SHAL BE BURIED 30' BELOW FINISHED GRADE. 12. A CERTIFIED CONTRACTOR SHALL ADMINISTER ALL REQUIRED TESTS FOR DETERMINING THE OPERATIONAL QUALITY OF THE GROUNDING SYSTEM. THE GROUNDING SYSTEM SHALL BE TESTED USING A MEGGER OR APPROVED EQUIVALENT TESTING INSTRUMENT. THREE TESTS SHALL BE ISSUED FOR DETERMINING THE RESISTANCE OF THE GROUNDING SYSTEM: 1 TEST AT 100 FEET, 1 TEST AT 70 FEET, AND 1 TEST AT 35 FEET. THESE TEST LOCATIONS ARE GENERIC DISTANCES, ARE SUBJECT TO CHANGE, AND SHOULD BE VERIFIED ON A SITE BY SITE BASIS. VOICESTREAM WIRELESS SHALL BE GIVEN 24 HOURS NOTICE PRIOR TO THE TESTING OF THE GROUNDING SYSTEM. THE COST ASSOCIATED WITH GROUND TESTING SHALL BE AT THE EXPENSE OF THE CONTRACTOR. 13. ALL CONDUCTORS BONDING EQUIPMENT TO THE GROUND RING SHALL BE 82 SOLID BARE TINNED COPPER WIRE, UNLESS NOTED OTHERWISE. SYMBOL LEGEND MGB MASTER GROUND BAR 1/4'x4'524' COPPER AGB ACCESSORY GROUND BAR 1/4'04'x12' OR TT 1/4N41Q0' COPPER EXPOSED WIRING - - - - - UNDERGROUND WIRING • CADWELD • MECHANICAL CONNECTION • 5/8'x8' COPPER CLAD STEEL GROUND ROD INSPECTION PORT 1 GROUND DUAL -POLE ANTENNA (TYP.) 12 THOU GREEN TO ANTENNA MOUNT AGB MOUNTED TO MONOPOLE DIRECTLY BELOW ANTENNAS 02 THOU GREEN ROUTED WITH ANTENNA CABLES MOB MOUNTED TO MONOPOLE AT BOTTOM 1 1 1 1 1 • ANTENNA JUMPER CABLE, SEE SHEETS RF-1 AND RF-2 FOR DETAILS BOND LNA TO ANTENNA MOUNT W/12 GREEN THW LNA EQUIPMENT - SEE SHEET RF-2 FOR ADDITIONAL INFORMATION GROUND AND WEATHER PROOFING ISMS. INSTALL BELOW ANTENNAS. (TYP.) GROUND TAIL. (TYP.) COAXIAL CABLE, SEE SHEETS RF-I AND RF-2 FOR DETAILS (TYP) GROUND AND WEATHERPROOFING IQTS, LOCATED NEAR EQUIPMENT. (TYP.) 02 THW GREEN (TYP) MOUNT MOB ON ICE BRIDGE NEAR BIS EQUIPMENT C) 1 ANTENNA GROUNDING RISER E 3 NT.S. EQUIPMENT JUMPER CABLE, SEE SHEETS RF -1 AND RF:2 FOR DETAIL FENCE POST CADWELD III --- - r SITE GROUNDING RING - - - - -- - -- L------------------- - - - - - -BOND ALL BTS EQUIPMENT TO MGB -P2 THW GREEN (TYP) BOND MOB TO GROUND RING -02 SOLID BARE TINNED COPPER (TYP ALL MGB'S) — — 82 SOUD BARE TINNED COPPER CONCRETE FOOTING BOND CABINET GIRD. BAR TO GROUND RING -92 SOUD BARE TINNED COPPER GATE POST. TYP. FLEXIBLE COPPER BRAID BURNDY TYPE "8 WITH SLEEVES ON EACH END DESIGNED FOR CADWELDS OR EQUAL CADWELD. TYP. FENCE GROUNDING DETAILS 8-3 N.T.B. U2 SOUD BARE TINNED COPPER CONCRETE FOOTING 19807 NORTHCREEK PKWY N BOTHELL, WA 98011 OFFICE (428) 398.7800 PROJECT INFORMATION. MILITARY & 27TH SE3551C 3118 S 140TH ST TUKWILA, WA 98168 — ISSUED FOR: C _REVISION HISTORY: BUILDING PERMIT No. DATE, DESCRIPTION: =PLANS PREPARED BY: — DRAWN BY: I LICENSURE: CHK. ADP/. 97, 871 B. J. THOMAS, P.E. 7607 80TH AVE NE MARYSVILLE, WA 98270 206. 851.1106 CH& BY : =APPV. BY:— AAL BJT AM - EQUIPMENT: DRAWING INFORMATION: DO NOT SCALE DRAWINGS. CONTRACTOR MUST VERIFY ALL DIMENSIONS AND ADVISE CONSULTANTS OF ANY ERRORS AND OMISSIONS. ALL PREVIOUS ISSUES OF THIS DRAWING ARE SUPERSEDED BY THE LATEST REVISION. THE INFORMATION CONTAINED IN THIS SET OF DOCUMENTS LS PROPRIETARY BY NATURE. ANY USE OR DISCLOSURE OTHER THAN WHICH IS RELATED TO NAMED CLIENT IS STRICTLY PROHIBITED. DRAWING TITLE: ELECTRICAL GROUNDING DETAILS DRAWING NUMBER: VOICESTREAM WIRELESS ANTENNAS COLLOCATED ON AN EXISTING 53' AGL STEEL MONOPOLE WITH BTS EQUIPMENT IN A 8 16.0 FENCED HALF VAULT LEASE AREA. E -3 �/4�� 8/15/2008 ISSUED FOR BUILDING PERMIT BJT MP /g\ 3/13/2006 MINOR REVISIONS BJT MP A/ 12/29/2005 ISSUED FOR ZONING BJT MP / 12/15/2005 ISSUED DESIGN REVIEW BJT MP DUAL -POLE ANTENNA (TYP.) 12 THOU GREEN TO ANTENNA MOUNT AGB MOUNTED TO MONOPOLE DIRECTLY BELOW ANTENNAS 02 THOU GREEN ROUTED WITH ANTENNA CABLES MOB MOUNTED TO MONOPOLE AT BOTTOM 1 1 1 1 1 • ANTENNA JUMPER CABLE, SEE SHEETS RF-1 AND RF-2 FOR DETAILS BOND LNA TO ANTENNA MOUNT W/12 GREEN THW LNA EQUIPMENT - SEE SHEET RF-2 FOR ADDITIONAL INFORMATION GROUND AND WEATHER PROOFING ISMS. INSTALL BELOW ANTENNAS. (TYP.) GROUND TAIL. (TYP.) COAXIAL CABLE, SEE SHEETS RF-I AND RF-2 FOR DETAILS (TYP) GROUND AND WEATHERPROOFING IQTS, LOCATED NEAR EQUIPMENT. (TYP.) 02 THW GREEN (TYP) MOUNT MOB ON ICE BRIDGE NEAR BIS EQUIPMENT C) 1 ANTENNA GROUNDING RISER E 3 NT.S. EQUIPMENT JUMPER CABLE, SEE SHEETS RF -1 AND RF:2 FOR DETAIL FENCE POST CADWELD III --- - r SITE GROUNDING RING - - - - -- - -- L------------------- - - - - - -BOND ALL BTS EQUIPMENT TO MGB -P2 THW GREEN (TYP) BOND MOB TO GROUND RING -02 SOLID BARE TINNED COPPER (TYP ALL MGB'S) — — 82 SOUD BARE TINNED COPPER CONCRETE FOOTING BOND CABINET GIRD. BAR TO GROUND RING -92 SOUD BARE TINNED COPPER GATE POST. TYP. FLEXIBLE COPPER BRAID BURNDY TYPE "8 WITH SLEEVES ON EACH END DESIGNED FOR CADWELDS OR EQUAL CADWELD. TYP. FENCE GROUNDING DETAILS 8-3 N.T.B. U2 SOUD BARE TINNED COPPER CONCRETE FOOTING 19807 NORTHCREEK PKWY N BOTHELL, WA 98011 OFFICE (428) 398.7800 PROJECT INFORMATION. MILITARY & 27TH SE3551C 3118 S 140TH ST TUKWILA, WA 98168 — ISSUED FOR: C _REVISION HISTORY: BUILDING PERMIT No. DATE, DESCRIPTION: =PLANS PREPARED BY: — DRAWN BY: I LICENSURE: CHK. ADP/. 97, 871 B. J. THOMAS, P.E. 7607 80TH AVE NE MARYSVILLE, WA 98270 206. 851.1106 CH& BY : =APPV. BY:— AAL BJT AM - EQUIPMENT: DRAWING INFORMATION: DO NOT SCALE DRAWINGS. CONTRACTOR MUST VERIFY ALL DIMENSIONS AND ADVISE CONSULTANTS OF ANY ERRORS AND OMISSIONS. ALL PREVIOUS ISSUES OF THIS DRAWING ARE SUPERSEDED BY THE LATEST REVISION. THE INFORMATION CONTAINED IN THIS SET OF DOCUMENTS LS PROPRIETARY BY NATURE. ANY USE OR DISCLOSURE OTHER THAN WHICH IS RELATED TO NAMED CLIENT IS STRICTLY PROHIBITED. DRAWING TITLE: ELECTRICAL GROUNDING DETAILS DRAWING NUMBER: VOICESTREAM WIRELESS ANTENNAS COLLOCATED ON AN EXISTING 53' AGL STEEL MONOPOLE WITH BTS EQUIPMENT IN A 8 16.0 FENCED HALF VAULT LEASE AREA. E -3 TYPE TA TYPE VN TYPE NC TYPE SS 14 . ,, 1 „„, TYPE W �� � TYPE 4, III VB i, „.:. TYPE PT TYPE I I GT TYPE GY TYPE GR ISSUED FOR TYPE GL 0 0 N.T.S. TYPICAL CADWELD CONNECTIONS N.T.S. 9 0 MAIN CONDUCTOR, COPPER CABLE O 51818 COPPER CLAD STEEL GROUND ROD O CADWELD TYPE TA' ® CADWELD TYPE GT GROUND ROD CONNECTION COVER TOP OF GRADE 5/8' GROUND ROD 0 METAL FRAME WITH SOLID UD ENGRAVED WPGROUND ON LID OF COVER W/1'0 LIFT HOLE AT CENTER OF COVER GROUND WELL, 12 0 x 24' LONG CONC. PIPE WITH COVER (SEE ABOVE) \,/ i 1i i ' #2 BARE TINNED COPPER LOOPED IN TEST WELL PERIMTTER GROUND RING GROUND INSPECTION WELL N.T.S. HARGER GROUNDING BAR #6814824 (OR EQUAL) WITH HOLE PATTERN, STANDOFF INSULATORS AND MOUNTING BRACKETS AS SHOWN #2 GREEN INSULATED COPPER WIRE TO AGB AT TOP OF POLE COAX CABLE GROUNDING KITS WITH LONG BARREL COMPRESSION LUGS, INSTALLED BY CONTRACTOR. - = CADWELD 3/8' S.S. HEXNUT 343' S.S STAR WASHER (TYP.) #2 STRD. GREEN INSULATED WIRE 0 MGB AT BTS EQUIPMENT & BOTTOM OF POLE N.T.S. #2 SOLID BARE TINNED COPPER WIRE TO GROUND RING - PROVIDE (2) PER MGB 0 N.T.S. GROUND BAR DETAILS BUSS BAR OR FLAT SURFACE OF EQUIP. / WIREWAY NO-LUX ANT -OXIDIZING COMPOUND 3/8' X 1' S.S HEXBOLT 3/8' S.S LOCKWASHER (TYP.) 3/8' X 1/7 S.S FLAT WASHER (TYP.) NOTES 1. TYP. ALL GROUND WIRES FOR ELECT. AND OTHER EQUIPMENT. 2. THE ENTIRE LUG AND AREA TO BE SPRAYED WITH CLEAR IAQUER OR COLD GALWNI2JNG SPRAY 3. GROUND LEADS TO BE CADWELDED TO GROUND RING. HARGER GROUNDING BAR #69/144120 OR EQUAL ANTENNA MOUNT GROUND COAX CABLE GROUNDING KITS TA/0 HOLE COMPRESSION CRIMP LUG (#2) DETAIL IS TYP. OF TWO NUTS & BOLTS TYPICAL CABINET GROUNDING DETAIL AGB TOP OF POLE #2 GREEN INSULATED COPPER WIRE TO MGB AT BOTTOM OF POLE hkeirfeam 19807 NORTHCREEK PKWY N BOTHELL, WA 98011 OFFICE (423) 398.7600 PROJECT INFORMATION' MILITARY & 27TH SE3551C 3118S140THST TUKWILA, WA 98188 ISSUED FOR: C _ REVISION HISTORY: BUILDING PERMIT No. DATE: DESCRIPTION: CHK. APPV. BY. BY PLANS PREPARED BY: B. J. THOMAS, P.E. 7607 80TH AVE NE MARYSVILLE, WA 98270 206.851.1106 C DRAWN BY: LICENSURE: CHK. BY: = APPV. BY: AAL BJT AM EQUIPMENT: [DRAWING INFORMATION: DRAWING TITLE: DRAWING NUMBER: VOICESTREAM WIRELESS ANTENNAS COLLOCATED ON AN EXISTING 53' AGL STEEL MONOPOLE WITH BTS EQUIPMENT IN A 8'8' x 18'-0' FENCED HALF VAULT LEASE AREA DO NOT SCALE DRAWINGS. CONTRACTOR MUST VERIFY ALL DIMENSIONS AND ADVISE CONSULTANTS OF ANY ERRORS AND OMISSIONS. ALL PREVIOUS ISSUES OF THIS DRAWING ARE SUPERSEDED BY THE LATEST REVISION. THE INFORMATION CONTAINED IN THIS SET OF DOCUMENTS IS PROPRIETARY BY NATURE. ANY USE OR DISCLOSURE OTHER THAN WHICH IS RELATED TO NAMED CLIENT IS STRICTLY PROHIBITED. ELECTRICAL GROUNDING DETAILS E.4 A 5/15/2006 ISSUED FOR B,/T MP PERMIT / 3/132008 MINOR REVISIONS BJT MP //y�\ !/' 12/292005 ISSUED FOR ZONING BJT MP \ 12/15/2005 ISSUED DESIGN REVIEW BJT MP 0 0 N.T.S. TYPICAL CADWELD CONNECTIONS N.T.S. 9 0 MAIN CONDUCTOR, COPPER CABLE O 51818 COPPER CLAD STEEL GROUND ROD O CADWELD TYPE TA' ® CADWELD TYPE GT GROUND ROD CONNECTION COVER TOP OF GRADE 5/8' GROUND ROD 0 METAL FRAME WITH SOLID UD ENGRAVED WPGROUND ON LID OF COVER W/1'0 LIFT HOLE AT CENTER OF COVER GROUND WELL, 12 0 x 24' LONG CONC. PIPE WITH COVER (SEE ABOVE) \,/ i 1i i ' #2 BARE TINNED COPPER LOOPED IN TEST WELL PERIMTTER GROUND RING GROUND INSPECTION WELL N.T.S. HARGER GROUNDING BAR #6814824 (OR EQUAL) WITH HOLE PATTERN, STANDOFF INSULATORS AND MOUNTING BRACKETS AS SHOWN #2 GREEN INSULATED COPPER WIRE TO AGB AT TOP OF POLE COAX CABLE GROUNDING KITS WITH LONG BARREL COMPRESSION LUGS, INSTALLED BY CONTRACTOR. - = CADWELD 3/8' S.S. HEXNUT 343' S.S STAR WASHER (TYP.) #2 STRD. GREEN INSULATED WIRE 0 MGB AT BTS EQUIPMENT & BOTTOM OF POLE N.T.S. #2 SOLID BARE TINNED COPPER WIRE TO GROUND RING - PROVIDE (2) PER MGB 0 N.T.S. GROUND BAR DETAILS BUSS BAR OR FLAT SURFACE OF EQUIP. / WIREWAY NO-LUX ANT -OXIDIZING COMPOUND 3/8' X 1' S.S HEXBOLT 3/8' S.S LOCKWASHER (TYP.) 3/8' X 1/7 S.S FLAT WASHER (TYP.) NOTES 1. TYP. ALL GROUND WIRES FOR ELECT. AND OTHER EQUIPMENT. 2. THE ENTIRE LUG AND AREA TO BE SPRAYED WITH CLEAR IAQUER OR COLD GALWNI2JNG SPRAY 3. GROUND LEADS TO BE CADWELDED TO GROUND RING. HARGER GROUNDING BAR #69/144120 OR EQUAL ANTENNA MOUNT GROUND COAX CABLE GROUNDING KITS TA/0 HOLE COMPRESSION CRIMP LUG (#2) DETAIL IS TYP. OF TWO NUTS & BOLTS TYPICAL CABINET GROUNDING DETAIL AGB TOP OF POLE #2 GREEN INSULATED COPPER WIRE TO MGB AT BOTTOM OF POLE hkeirfeam 19807 NORTHCREEK PKWY N BOTHELL, WA 98011 OFFICE (423) 398.7600 PROJECT INFORMATION' MILITARY & 27TH SE3551C 3118S140THST TUKWILA, WA 98188 ISSUED FOR: C _ REVISION HISTORY: BUILDING PERMIT No. DATE: DESCRIPTION: CHK. APPV. BY. BY PLANS PREPARED BY: B. J. THOMAS, P.E. 7607 80TH AVE NE MARYSVILLE, WA 98270 206.851.1106 C DRAWN BY: LICENSURE: CHK. BY: = APPV. BY: AAL BJT AM EQUIPMENT: [DRAWING INFORMATION: DRAWING TITLE: DRAWING NUMBER: VOICESTREAM WIRELESS ANTENNAS COLLOCATED ON AN EXISTING 53' AGL STEEL MONOPOLE WITH BTS EQUIPMENT IN A 8'8' x 18'-0' FENCED HALF VAULT LEASE AREA DO NOT SCALE DRAWINGS. CONTRACTOR MUST VERIFY ALL DIMENSIONS AND ADVISE CONSULTANTS OF ANY ERRORS AND OMISSIONS. ALL PREVIOUS ISSUES OF THIS DRAWING ARE SUPERSEDED BY THE LATEST REVISION. THE INFORMATION CONTAINED IN THIS SET OF DOCUMENTS IS PROPRIETARY BY NATURE. ANY USE OR DISCLOSURE OTHER THAN WHICH IS RELATED TO NAMED CLIENT IS STRICTLY PROHIBITED. ELECTRICAL GROUNDING DETAILS E.4 ANTENNA SECTOR ANTENNA MODEL # VENDOR AZIMUTH (TN) MECHANICAL DOWNTILT RADIATION CENTER CABLE LENGTH COAXIAL CABLE NUMBER OF COAX RUNS A -1 ALPHA ADFDP- 182-6565B -XDM ANDREW 150' 0' 50'-0' 120' ANDREW 7/8' DIA. 4 13-1 BETA ADFDP - 182-65658 -XDM ANDREW 340' 0' 50-0" 120 ANDREW 7/8'DIA 4 GPS N/A RRSI A SYMMETRICOM N/A WA TBD TBD ANDREW 1/2' Mk 1 911 N/A BSDB18U8 COMTELCO WA N/A TBD TBD ANDREW NT DIA 1 TYPE OF EQUIPMENT LENGTH OF CABLE RUN DIA. OF CABLES MIN. BENDING RADIUS CITYTALK/ ULTRASITES 3-0', 6'-0', AND 100' 1/2 11/4' SUPERFLEX JUMPER RUNS CITYTALK/ ULTRASITES 3-0', 0-0', AND lO-0' FLEX JUMPER RUNS 1/2 4' ULTRASITES 0' THRU 100-0' 7/8' 10' ULTRASITES W)LNA 101' THRU 150-0' 7/8' 10' ULTRASITES 151'-0' AND GREATER 1 5/8' 20' CITYTALK 0' THRU 170-0• 7/8' 117' CITYTALK 131'-0' AND GREATER 1 5/8' 20' COAXIAL CABLE NOTES: 1 ALL COAXIAL CABLE CONNECTIONS TO BE WEATHERPROOFED. 2 CONTRACTOR TO PROVIDE DRIP LOOPS IN CABLES AND JUMPERS WHERE NECESSARY. 3 TAGGING: 4 3.1 ALL COAXIAL CABLES TO BE MARKED WITH COLOR CODED TAPE TO INDICATE THE ANTENNA SECTOR. 3.2 COLORED ELECTRICAL TAPE SHALL MARK EACH END OF CABLE AND EACH END OF JUMPERS AS CLOSE TO EACH END AS POSSIBLE. (NOT TO INTERFERE WITH WEATHERPROOFING). COAXIAL CABLE SPECIFICATIONS REQUIRE CABLE SUPPORT EVERY 3'-0' ON CENTER. CONTRACTOR SHALL SUPPLY SUPPORTS AS REQUIRED TO MEET THIS REQUIREMENT. CONNECTORS STEP 1 CANUSA HEAVY WALL HEAT SHRINK ALL COAX CONNECTIONS INSTALL PER MANUFACTURERS INSTRUCTIONS 0 N.T.S. SITE LOADING CHART ELECTRICAL TAPE (1 LAYER) STEP 3 STEP 2 COAXIAL CABLE WEATHERPROOFING ANTENNA AND COAX GENERAL NOTES 1. ALL ANTENNA AND COAXIAL ANTENNA CABLE TO BE FURNISHED BY VOICESTREAM AND INSTALLED BY CONTRACTOR. 2. COAX COLOR CODING: ANTENNAS TO BE NUMBERED IN A CLOCKWISE MANNER FROM TRUE NORTH AND COLOR CODED AS FOLLOWS: 3 5 BETA SECTOR SECTOR ALPHA SECTOR #1 AT ANTENNA CONNECTION #2 AT ENTRY TO EQUIPMENT CABINET ANTENNA DESIGNATION - COLOR CODING Al - 1 RED BAND A3 - 3 RED BANDS A4 - 4 RED BANDS A2 - 2 RED BAWDS 81 - 1 GREEN BAND 83 - 3 GREEN BANDS 84 - 4 GREEN BANDS B2 - 2 GREEN BANDS 4. THE ABOVE COAX COLOR CODING APPLIES TO SECTORIZED SITES: FOR OMNI SITES USE THE ATO, BTO, GTO COLOR CODES ONLY. COAX SHALL BE TAGGED WITH COLOR CODING AT (2) PLACES USING 1" WIDE WEATHERPROOF COLORED VINYL TAPE, AT THE FOLLOWING LOCATIONS: RUN COAXIAL CABLE WITH MINIMUM 12' SLACK 1T FROM EDGE OF EQUIPMENT CABINETS, THROUGH PCV COAX CONDUITS, UP INTERIOR OF MONOPOLE AND DISTRIBUTE TO EACH ANTENNA DEVICE. FURNISH AND INSTALL MINIMUM OF (3) GROUND KITS PER COAXIAL CABLE PER ELECTRICAL DRAWINGS. VERIFY NUMBER OF ANTENNAS, CABLE AND CABLE DIAMETER WITH PROJECT MANAGER. Tx AND Rx FREQUENCIES FOR SEATTLE MARKET: Tx: 1965 -1985 Mhz Rx: 1885 - 1905 Mhz COAXIAL CABLE SPECIFICATIONS WICeSgealn 19807 NORTHCREEK PKWY N BOTHELL. WA 98011 OFFICE (425) 398.7600 = PROJECT INFORMATION. MILITARY & 27TH SE3551 C 3118 S 140TH ST TUKWILA, WA 98188 ISSUED FOR: C _REVISION HISTORY: BUILDING PERMIT No. DATE: DESCRIPTION: =PLANS PREPARED BY -DRAWN BY: _LICENSURE: CHIC. APPV. BY BY B. J. THOMAS, P.E. 7607 80TH AVE NE MARYSVILLE, WA 98270 206-851-1106 CHIC. BY:: APPV. BY: : AAL BJT AM " EQUIPMENT: DRAWING INFORMATION: DO NOT SCALE DRAWINGS. CONTRACTOR MUST VERIFY ALL DIMENSIONS AND ADVISE CONSULTANTS OF ANY ERRORS AND OMISSIONS. ALL PREVIOUS ISSUES OF THIS DRAWING ARE SUPERSEDED BY THE LATEST REVISION. THE INFORMATION CONTAINED IN THIS SET OF DOCUMENTS IS PROPRIETARY BY NATURE. ANY USE OR DISCLOSURE OTHER THAN WHICH IS RELATED TO NAMED CLIENT IS STRICTLY PROHIBRED. DRAWING TITLE. RF DETAILS DRAWING NUMBER: VOICESTREAM WIRELESS ANTENNAS COLLOCATED ON AN EXISTING 53' AGL STEEL MONOPOLE WITH BTS EQUIPMENT IN A 8'8' x 16'-0" FENCED HALF VAULT LEASE AREA. RF -1 A 8/15/2006 � FOR BJT MP BUILDING PERMIT / ' \ 3/13/2006 MINOR REVISIONS BJT MP /2\ 12/29/2005 ISSUED FOR ZONING BJT MP / 1 \ 12/15/2005 ISSUED DESIGN REVIEW BJT MP COAXIAL CABLE NOTES: 1 ALL COAXIAL CABLE CONNECTIONS TO BE WEATHERPROOFED. 2 CONTRACTOR TO PROVIDE DRIP LOOPS IN CABLES AND JUMPERS WHERE NECESSARY. 3 TAGGING: 4 3.1 ALL COAXIAL CABLES TO BE MARKED WITH COLOR CODED TAPE TO INDICATE THE ANTENNA SECTOR. 3.2 COLORED ELECTRICAL TAPE SHALL MARK EACH END OF CABLE AND EACH END OF JUMPERS AS CLOSE TO EACH END AS POSSIBLE. (NOT TO INTERFERE WITH WEATHERPROOFING). COAXIAL CABLE SPECIFICATIONS REQUIRE CABLE SUPPORT EVERY 3'-0' ON CENTER. CONTRACTOR SHALL SUPPLY SUPPORTS AS REQUIRED TO MEET THIS REQUIREMENT. CONNECTORS STEP 1 CANUSA HEAVY WALL HEAT SHRINK ALL COAX CONNECTIONS INSTALL PER MANUFACTURERS INSTRUCTIONS 0 N.T.S. SITE LOADING CHART ELECTRICAL TAPE (1 LAYER) STEP 3 STEP 2 COAXIAL CABLE WEATHERPROOFING ANTENNA AND COAX GENERAL NOTES 1. ALL ANTENNA AND COAXIAL ANTENNA CABLE TO BE FURNISHED BY VOICESTREAM AND INSTALLED BY CONTRACTOR. 2. COAX COLOR CODING: ANTENNAS TO BE NUMBERED IN A CLOCKWISE MANNER FROM TRUE NORTH AND COLOR CODED AS FOLLOWS: 3 5 BETA SECTOR SECTOR ALPHA SECTOR #1 AT ANTENNA CONNECTION #2 AT ENTRY TO EQUIPMENT CABINET ANTENNA DESIGNATION - COLOR CODING Al - 1 RED BAND A3 - 3 RED BANDS A4 - 4 RED BANDS A2 - 2 RED BAWDS 81 - 1 GREEN BAND 83 - 3 GREEN BANDS 84 - 4 GREEN BANDS B2 - 2 GREEN BANDS 4. THE ABOVE COAX COLOR CODING APPLIES TO SECTORIZED SITES: FOR OMNI SITES USE THE ATO, BTO, GTO COLOR CODES ONLY. COAX SHALL BE TAGGED WITH COLOR CODING AT (2) PLACES USING 1" WIDE WEATHERPROOF COLORED VINYL TAPE, AT THE FOLLOWING LOCATIONS: RUN COAXIAL CABLE WITH MINIMUM 12' SLACK 1T FROM EDGE OF EQUIPMENT CABINETS, THROUGH PCV COAX CONDUITS, UP INTERIOR OF MONOPOLE AND DISTRIBUTE TO EACH ANTENNA DEVICE. FURNISH AND INSTALL MINIMUM OF (3) GROUND KITS PER COAXIAL CABLE PER ELECTRICAL DRAWINGS. VERIFY NUMBER OF ANTENNAS, CABLE AND CABLE DIAMETER WITH PROJECT MANAGER. Tx AND Rx FREQUENCIES FOR SEATTLE MARKET: Tx: 1965 -1985 Mhz Rx: 1885 - 1905 Mhz COAXIAL CABLE SPECIFICATIONS WICeSgealn 19807 NORTHCREEK PKWY N BOTHELL. WA 98011 OFFICE (425) 398.7600 = PROJECT INFORMATION. MILITARY & 27TH SE3551 C 3118 S 140TH ST TUKWILA, WA 98188 ISSUED FOR: C _REVISION HISTORY: BUILDING PERMIT No. DATE: DESCRIPTION: =PLANS PREPARED BY -DRAWN BY: _LICENSURE: CHIC. APPV. BY BY B. J. THOMAS, P.E. 7607 80TH AVE NE MARYSVILLE, WA 98270 206-851-1106 CHIC. BY:: APPV. BY: : AAL BJT AM " EQUIPMENT: DRAWING INFORMATION: DO NOT SCALE DRAWINGS. CONTRACTOR MUST VERIFY ALL DIMENSIONS AND ADVISE CONSULTANTS OF ANY ERRORS AND OMISSIONS. ALL PREVIOUS ISSUES OF THIS DRAWING ARE SUPERSEDED BY THE LATEST REVISION. THE INFORMATION CONTAINED IN THIS SET OF DOCUMENTS IS PROPRIETARY BY NATURE. ANY USE OR DISCLOSURE OTHER THAN WHICH IS RELATED TO NAMED CLIENT IS STRICTLY PROHIBRED. DRAWING TITLE. RF DETAILS DRAWING NUMBER: VOICESTREAM WIRELESS ANTENNAS COLLOCATED ON AN EXISTING 53' AGL STEEL MONOPOLE WITH BTS EQUIPMENT IN A 8'8' x 16'-0" FENCED HALF VAULT LEASE AREA. RF -1 ALPHA SECTOR 1 RED TX/RX 3 RED 4 RED 2 RED BETA SECTOR 1 GREEN 3 GREEN 4 GREEN 2 GREEN EQUIPMENT CABINETS TX/RX 2 7 3/4• (ANTENNA) 0 1'-0 7B' N.T.S. 6'0 SUPERFLEX JUMPER CABLE 0-0' SUPERFLEX JUMPER GABLE 6%0' SUPERFLEX JUMPER CABLE SUPERFLEX JUMPER CABLE 6%0' SUPERFLEX JUMPER CABLE 6'-0' SUPERFLEX JUMPER CABLE 6'-0' SUPERFLEX JUMPER CABLE SUPERFLEX JUMPER CABLE 5 1/8' (MOUNTING BASE) ■ I7 GPS ANTENNA DATA MECHANICAL SPECIFICATIONS PART NUMBER I HEIGHT I DIAMETER WEIGHT 54ri2A 6.42 (163mm) 3.54'0 (90mm) 115 az (427,) CONNECTORS I MOUNTING HARDWARE I TYPE N OPTION AUB MAST ELECTRICAL SPECIFICATIONS 1565. 2 - 1585.42MHz I RIGHT-HAND CIRCULAR I>30 481 I 2.5 12 POWER R CW NG GPS ANTENNA SPECIFICATIONS DIN(F) 7/8' COAXIAL CABLE - 110 -DIN (F)1 DIN (F) COAXIAL CABLE DIAGRAM N.T.S. TYPE TP CONNECTOR IN BASE OF ANTENNA 7B• COAXIAL 7-0' FLEX 3'-0' FLEX CABLE -120' JUMPER CABLE ' JUMPER CABLE 7/8' COAXIAL CABLE - 120 7B' COAXIAL CABLE -120 7B' COAXIAL CABLE -110' TYPE W CONNECTOR IN BASE OF ANTENNA 0 N.T.S. CM1 ■ r11= ■ MEI ■ COMUI ■ 8'-0' FLEX JUMPER CABLE 6'-0' FLEX JUMPER CABLE 7/8' COAXIAL 7-0' FLEX 3'-0' FLEX CABLE -120' JUMPER CABLE JUMPEL R CABLE DIN (F) CEID] ■ ■ LNA IF . - � T 7/8' COAXIAL 7.0' FLEX 3 FLEX �-y DIN(F)I CABLE - 110' JUMPER CABLE ' JUMPER CABLE LNA IIF- --�I 6'-0' FLEX JUMPER CABLE 8'-0' FLEX JUMPER CABLE 7/8' COAXIAL 3'-0' FLEX 3'-0' FLEX CABLE -110' JUMPER CABLE ' JUMPER CABLE Q 911 ANTENNA DATA MECHANICAL SPECIFICATIONS PART BSDB18U8 ER 1151n T 1 1DIAMETER 1 41500 I (1))TYPEN CONNECTORS I STANDARD MOUNTING HARDWARE I BSMNT1 ELECTRICAL SPECIFICATIONS ER RATING 825 -896, 1850-1990 MHz I UNITY 175'R„GAL B.W. I VSWR I 2 20 WATTS 911 ANTENNA SPECIFICATIONS -4 A -2 ADFDP- 182 6565B-XDM B-1 9.2 ADFDP-182-6565B-XDM SWEEP TEST PROCEDURE: THE FOLLOWING PROCEDURE DESCRIBES THE TEST AND FAULT FINDING PROCEDURE TO BE FOLLOWED FOR ALL ANTENNAS 1. TEST EQUIPMENT SHOULD CONSIST OF A SWEEP OSCILLATOR SET TO RUN BETWEEN 1800 AND 2000 MHz, DIRECTIONAL COUPLER WITH AT LEAST 3548 DIRECTIVITY AND SCALAR NETWORK ANALYZER WITH RESOLUTION OF BETTER THAN 0.248. A MATCHED 50 Ohm LOAD AND SHORT CIRCUIT TERMINATION ARE ALSO REOUIRED. 2. SET UP THE RETURN LOSS MEASURING SET AS PER THE MANUFACTURERS INSTRUCTIONS AND CALIBRATE WITH THE SHORT (04B RETURN LOSS VSWR = INFINITY.) 4. COMPOSITE RETURN LOSS: DISCONNECT THE BOTTOM JUMPER AT THE BTS AND CONNECT IT TO THE MAIN PORT OF THE BRIDGE. RETURN LOSS OF THE COMPOSITE JUMPERS, FEEDER AND ANTENNA SHOULD BE < -184B (VSWR > 1.5: 1) BETWEEN 1800 AND 2000 MHZ 4. FEEDER RETURN LOSS: TURN OFF THE SWEEP GENERATOR, DISCONNECT THE TOP JUMPER AT THE ANTENNA AND CONNECT A DUMMY LOAD TO THE END OF THE TOP JUMPER WITH A DIN - N ADAPTER. POWER UP THE GENERATOR AND MEASURE THE RETURN LOSS LOOKING INTO THE BOTTOM JUMPER. THE RETURN LOSS SHOULD NOT EXCEED -1848 ( VSWR > 1.3 : 1) BETWEEN 1800 AND 2000MHZ 5. FEEDER INSERTION LOSS: REPLACE THE LOAD WITH A SHORT CIRCUIT TERMINATION AND MEASURE THE MAXIMUM AND MINIMUM RETURN LOSS BETWEEN 1800 AND 2000. ADD THIS TOGETHER AND DIVIDE BY 4 TO GIVE THE AVERAGE 1 WAY INSERTION LOSS WHICH SHOULD BE < 34B. 8. IF THE CONDITIONS IN 4, 5 AND 6 ARE MET THEN THE TEST IS COMPLETE. IF 4 IS BAD BUT 5 & B ARE OK THEN REPLACE THE ANTENNA AND RETEST. IF 58 ARE BAD THEN MEASURE RL OF MAIN FEEDER ONLY. IF RETURN LOSS IMPROVES TO -20 OR BETTER OR INSERTION LOSS IMPROVES BY MORE THAN 248 THEN REPLACE OR RETERMINATE THE BOTTOM AND TOP JUMPER. OTHERWISE REPLACE THE MAIN FEEDER RUN. NOTIFY PROJECT MANAGEMENT AND RF ENGINEERING OF ANY FAULTY HARDWARE. 7. ALL TEST RESULTS SHOULD BE CLEARLY MARKED WITH SITE, FEEDER NUMBER, DATE, MEASURED TIME. ELECTRICAL TAPE OVER MASTIC TAPE CB FIGURE 1 MEI FIGURE 4 RF-2 0 GROUNDING STRAP ASSEMBLY SCALE: NO SCALE N.T.S. GROUNDING SLOT FOR CLAMP i I / ADJUSTABLE BAND CLAMP FIGURE 2 1/4' 20 HARDWARE ADJUSTABLE BAND CLAMP GROUNDING CLAMP FIGURE 5 FIGURE 6 COAXIAL CABLE GROUNDING 54• 66 GROUND LEAD ANTENNA SPECIFICATIONS FIGURE 3 ANDREW ANTENNA DATA MECHANICAL SPECIFICATIONS PART NUMBER I HEIGHT ADFDP - 182 -65658 -XDM I 54 In I WIDTH DEPTH I WEIGHT 121n 3.5 51 34.5104 CONNECTORS I STANDARD MOUNTING HARDWAR E (4) 7 -16 DIN INCLUDED ELECTRICAL SPECIFICATIONS FREQUENCY I POLARIZATION I GAIN AZIMUTH B.W. ELEVATION .W. 1850-1990 MHz ±45' 15.2 031/ 17.6 466 I B 65' 6.5• BEAM 11171 VSWR I POWER HANDLING I 0% -7% <1.5:1 200 WATTS PUTTY TAPE '".■, 88 GROUND LEAD TWO 1OLE COMPRESSION CRIMP LUG (46) TO GROUND BAR 19807 NORTHCREEK PKWY N BOTHELL, WA 88011 OFFICE (425) 398.7600 _PROJECT INFORMATION. MILITARY & 27TH SE3551C 3118 S 140TH ST TUKWILA. WA 98188 - ISSUED FOR: C BUILDING PERMIT REVISION HISTORY: No. DATE SCRIPTION: CNK. APPY. E. BY: BE -120. SS UED BUILDING FO PR ERMIT BJT MP / 4 ! ///3��\ 3/13/2006 MINOR REVISIONS BJT MP // 2� \ 12292005 ISSUED FOR ZONING BJT MP /' \ 12/152005 ISSUED DESIGN REVIEW BJT MP — PLANS PREPARED BY: B. J. THOMAS, P.E. 7607 80TH AVE NE MARYSVILLE, WA 98270 206.851.1106 r DRAWN BY: CHIC. BY: = APPV. BY: AAL BJT AM LICENSURE- _ , t .4.- L . -6 .• 37411 r rC' E.'CPIRE OK ISO' J — EQUIPMENT: VOICESTREAM WIRELESS ANTENNAS COLLOCATED ON AN EXISTING 53' AGL STEEL MONOPOLE WITH BTS EQUIPMENT IN A 8%6' x 10-0' FENCED HALF VAULT LEASE AREA. _DRAWING INFORMATION: DO NOT SCALE DRAWINGS. CONTRACTOR MUST VERIFY ALL DIMENSIONS AND ADVISE CONSULTANTS OF ANY ERRORS AND OMISSIONS. ALL PREVIOUS ISSUES OF THIS DRAWING ARE SUPERSEDED BY THE LATEST REVISION. THE INFORMATION CONTAINED IN THIS SET OF DOCUMENTS IS PROPRIETARY BY NATURE. ANY USE OR DISCLOSURE OTHER THAN WHICH IS RELATED TO NAMED CLIENT IS STRICTLY PROHIBITED. = DRAWING TITLE: RF DETAILS = DRAWING NUMBER: RF -2 ALPHA SECTOR 1 RED TX/RX 3 RED 4 RED 2 RED BETA SECTOR 1 GREEN 3 GREEN 4 GREEN 2 GREEN EQUIPMENT CABINETS TX/RX 2 7 3/4• (ANTENNA) 0 1'-0 7B' N.T.S. 6'0 SUPERFLEX JUMPER CABLE 0-0' SUPERFLEX JUMPER GABLE 6%0' SUPERFLEX JUMPER CABLE SUPERFLEX JUMPER CABLE 6%0' SUPERFLEX JUMPER CABLE 6'-0' SUPERFLEX JUMPER CABLE 6'-0' SUPERFLEX JUMPER CABLE SUPERFLEX JUMPER CABLE 5 1/8' (MOUNTING BASE) ■ I7 GPS ANTENNA DATA MECHANICAL SPECIFICATIONS PART NUMBER I HEIGHT I DIAMETER WEIGHT 54ri2A 6.42 (163mm) 3.54'0 (90mm) 115 az (427,) CONNECTORS I MOUNTING HARDWARE I TYPE N OPTION AUB MAST ELECTRICAL SPECIFICATIONS 1565. 2 - 1585.42MHz I RIGHT-HAND CIRCULAR I>30 481 I 2.5 12 POWER R CW NG GPS ANTENNA SPECIFICATIONS DIN(F) 7/8' COAXIAL CABLE - 110 -DIN (F)1 DIN (F) COAXIAL CABLE DIAGRAM N.T.S. TYPE TP CONNECTOR IN BASE OF ANTENNA 7B• COAXIAL 7-0' FLEX 3'-0' FLEX CABLE -120' JUMPER CABLE ' JUMPER CABLE 7/8' COAXIAL CABLE - 120 7B' COAXIAL CABLE -120 7B' COAXIAL CABLE -110' TYPE W CONNECTOR IN BASE OF ANTENNA 0 N.T.S. CM1 ■ r11= ■ MEI ■ COMUI ■ 8'-0' FLEX JUMPER CABLE 6'-0' FLEX JUMPER CABLE 7/8' COAXIAL 7-0' FLEX 3'-0' FLEX CABLE -120' JUMPER CABLE JUMPEL R CABLE DIN (F) CEID] ■ ■ LNA IF . - � T 7/8' COAXIAL 7.0' FLEX 3 FLEX �-y DIN(F)I CABLE - 110' JUMPER CABLE ' JUMPER CABLE LNA IIF- --�I 6'-0' FLEX JUMPER CABLE 8'-0' FLEX JUMPER CABLE 7/8' COAXIAL 3'-0' FLEX 3'-0' FLEX CABLE -110' JUMPER CABLE ' JUMPER CABLE Q 911 ANTENNA DATA MECHANICAL SPECIFICATIONS PART BSDB18U8 ER 1151n T 1 1DIAMETER 1 41500 I (1))TYPEN CONNECTORS I STANDARD MOUNTING HARDWARE I BSMNT1 ELECTRICAL SPECIFICATIONS ER RATING 825 -896, 1850-1990 MHz I UNITY 175'R„GAL B.W. I VSWR I 2 20 WATTS 911 ANTENNA SPECIFICATIONS -4 A -2 ADFDP- 182 6565B-XDM B-1 9.2 ADFDP-182-6565B-XDM SWEEP TEST PROCEDURE: THE FOLLOWING PROCEDURE DESCRIBES THE TEST AND FAULT FINDING PROCEDURE TO BE FOLLOWED FOR ALL ANTENNAS 1. TEST EQUIPMENT SHOULD CONSIST OF A SWEEP OSCILLATOR SET TO RUN BETWEEN 1800 AND 2000 MHz, DIRECTIONAL COUPLER WITH AT LEAST 3548 DIRECTIVITY AND SCALAR NETWORK ANALYZER WITH RESOLUTION OF BETTER THAN 0.248. A MATCHED 50 Ohm LOAD AND SHORT CIRCUIT TERMINATION ARE ALSO REOUIRED. 2. SET UP THE RETURN LOSS MEASURING SET AS PER THE MANUFACTURERS INSTRUCTIONS AND CALIBRATE WITH THE SHORT (04B RETURN LOSS VSWR = INFINITY.) 4. COMPOSITE RETURN LOSS: DISCONNECT THE BOTTOM JUMPER AT THE BTS AND CONNECT IT TO THE MAIN PORT OF THE BRIDGE. RETURN LOSS OF THE COMPOSITE JUMPERS, FEEDER AND ANTENNA SHOULD BE < -184B (VSWR > 1.5: 1) BETWEEN 1800 AND 2000 MHZ 4. FEEDER RETURN LOSS: TURN OFF THE SWEEP GENERATOR, DISCONNECT THE TOP JUMPER AT THE ANTENNA AND CONNECT A DUMMY LOAD TO THE END OF THE TOP JUMPER WITH A DIN - N ADAPTER. POWER UP THE GENERATOR AND MEASURE THE RETURN LOSS LOOKING INTO THE BOTTOM JUMPER. THE RETURN LOSS SHOULD NOT EXCEED -1848 ( VSWR > 1.3 : 1) BETWEEN 1800 AND 2000MHZ 5. FEEDER INSERTION LOSS: REPLACE THE LOAD WITH A SHORT CIRCUIT TERMINATION AND MEASURE THE MAXIMUM AND MINIMUM RETURN LOSS BETWEEN 1800 AND 2000. ADD THIS TOGETHER AND DIVIDE BY 4 TO GIVE THE AVERAGE 1 WAY INSERTION LOSS WHICH SHOULD BE < 34B. 8. IF THE CONDITIONS IN 4, 5 AND 6 ARE MET THEN THE TEST IS COMPLETE. IF 4 IS BAD BUT 5 & B ARE OK THEN REPLACE THE ANTENNA AND RETEST. IF 58 ARE BAD THEN MEASURE RL OF MAIN FEEDER ONLY. IF RETURN LOSS IMPROVES TO -20 OR BETTER OR INSERTION LOSS IMPROVES BY MORE THAN 248 THEN REPLACE OR RETERMINATE THE BOTTOM AND TOP JUMPER. OTHERWISE REPLACE THE MAIN FEEDER RUN. NOTIFY PROJECT MANAGEMENT AND RF ENGINEERING OF ANY FAULTY HARDWARE. 7. ALL TEST RESULTS SHOULD BE CLEARLY MARKED WITH SITE, FEEDER NUMBER, DATE, MEASURED TIME. ELECTRICAL TAPE OVER MASTIC TAPE CB FIGURE 1 MEI FIGURE 4 RF-2 0 GROUNDING STRAP ASSEMBLY SCALE: NO SCALE N.T.S. GROUNDING SLOT FOR CLAMP i I / ADJUSTABLE BAND CLAMP FIGURE 2 1/4' 20 HARDWARE ADJUSTABLE BAND CLAMP GROUNDING CLAMP FIGURE 5 FIGURE 6 COAXIAL CABLE GROUNDING 54• 66 GROUND LEAD ANTENNA SPECIFICATIONS FIGURE 3 ANDREW ANTENNA DATA MECHANICAL SPECIFICATIONS PART NUMBER I HEIGHT ADFDP - 182 -65658 -XDM I 54 In I WIDTH DEPTH I WEIGHT 121n 3.5 51 34.5104 CONNECTORS I STANDARD MOUNTING HARDWAR E (4) 7 -16 DIN INCLUDED ELECTRICAL SPECIFICATIONS FREQUENCY I POLARIZATION I GAIN AZIMUTH B.W. ELEVATION .W. 1850-1990 MHz ±45' 15.2 031/ 17.6 466 I B 65' 6.5• BEAM 11171 VSWR I POWER HANDLING I 0% -7% <1.5:1 200 WATTS PUTTY TAPE '".■, 88 GROUND LEAD TWO 1OLE COMPRESSION CRIMP LUG (46) TO GROUND BAR