HomeMy WebLinkAboutPermit D06-325 - Quilting and Sewing Outlet - Tenant ImprovementQUILTING & SEWING
WORLD
1205 ANDOVER PK W
D06 -325
Parcel No.: 3523049092
Address: 1205 ANDOVER PK W TUKW
Suite No:
Tenant:
Name: QUILTING AND SEWING OUTLET
Address: 1205 ANDOVER PK W, TUKWILA WA
doe: IBC- PERMIT
City Ord Tukwila
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206 -431 -3670
Fax: 206 -431 -3665
Web site: ct.tukwila.wa.us
DEVELOPMENT PERMIT
Owner:
Name: WACO ENTERPRISE
Address' 1205 ANDOVER PARK W, TUKWILA WA, 98188
Phone:
Contact Person:
Name: DAVID KEHLE
Address: 12720 GATEWAY DR, STE 116, SEATTLE WA, 98168
Phone: 206 433 -8997
Contractor:
Name: KELLY THOMAS INC
Address: 26318 ENTWHISTLE RD E, BUCKLEY WA 98321
Phone: 253- 735 -3928
Contractor License No: KELLYTI148CR
DESCRIPTION OF WORK:
REMOVE EXTERIOR STAIRS AND WALLS AT FIRST FLOOR TO ABANDON EXISTING 2ND FLOOR OFFICE; INSTALL NEW
ADA RAMP AND STAIR; INSTALL NEW ADA RESTROOM; CRATE SMALL LUNCH AREA, SEPARATE OUT ELEC/TELEPHONE
AREA; DEFINE RETAIL (6496 SF) BY TENANT FIXTURES W/ PLYWOOD PANELS.
Value of Construction: $38,500.00 Fees Collected: $61,093.93
Type of Fire Protection: SPRINKLERS International Building Code Edition: 2003
Type of Construction: Occupancy per IBC:
* *continued on next page **
Expiration Date: 01/29/2008
Steven M. Mullet, Mayor
Steve Lancaster, Director
Permit Number: D06 -325
Issue Date. 09/29/2006
Permit Expires On: 03/28/2007
006 -325 Printed: 09 -29 -2006
Public Works Activities:
Channelization / Striping: N
Curb Cut / Access / Sidewalk / CSS: N
Fire Loop Hydrant:
Flood Control Zone:
Hauling:
Land Altering:
Landscape Irrigation:
Moving Oversize Load:
Sanitary Side Sewer:
Sewer Main Extension:
Storm Drainage:
Street Use:
Water Main Extension:
Water Meter:
Permit Center Authorized Signature: /4 /WM I tt—N arle3 /bf /l l'
this permit and know the same to be true and correct. All provisions of law and
ordinances goveming this work will b with, whether specified herein or not.
I hereby certify that I have read and
The granting of this p
regulating constru
Signature:
Print Name:
doc: IBC - PERMIT
City Or' Tukwila
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206 -431 -3670
Fax: 206 - 431 -3665
Web site: ettukwila.wa.us
N
N
N
Permit Number: D06 -325
Issue Date: 09/29/2006
Permit Expires On: 03/28/2007
Number: 0 Size (Inches): 0
Start Time: End Time:
Volumes: Cut 0 c.y. Fill 0 c.y.
Start Time: End Time:
Private: Public:
Profit: N Non - Profit: N
Private: Public:
Steven M. Mullet, Mayor
Steve Lancaster, Director
Date: piI Tat 161
it doe - of presume to give authority to violate or cancel the provisions of any other state or local laws
or ance of work. I am authorized to sign and obtain this development permi
Date: C i
This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is
suspended or abandoned for a period of 180 days from the last inspection.
D06 -325 Printed: 09-29 -2006
CITY O TUVV''1A
DEPT. OF Co ^.t: ;U; :i fY
6300 si uTHcLNTEP.
TUKWILA, WA 9 i3
`
PERMIT CONDITIONS
PERMIT CENTER
Parcel No.: 3523049092 Permit Number: D06 -325
Address: 1205 ANDOVER PK W TUKW Status: ISSUED
Suite No: Applied Date: 08/21/2006
Tenant: QUILTING AND SEWING OUTLET Issue Date: 09/29/2006
1: ***BUILDING DEPARTMENT CONDITIONS "'
2: No changes shall be made to the approved plans unless approved by the design professional in responsible charge and the
Building Official.
3: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center
(206/431- 3670).
4: All permits, inspection records, and approved plans shall be at the job site and available to the inspectors prior to
start of any construction. These documents shall be maintained and made available until final inspection approval is
granted.
5: All construction shall be done in conformance with the approved plans and the requirements of the International
Building Code or International Residential Code, International Mechanical Code, Washington State Energy Code.
6: Notify the City of Tukwila Building Division prior to placing any concrete. This procedure is in addition to any
requirements for special inspection.
7: All wood to remain in placed concrete shall be treated wood.
8: All rack storage requires a separate permit issued through the City of Tukwila Permit Center. Rack storage over 8 -feet
in height shall be anchored or braced to prevent overturning or displacement during seismic events. The design and
calculations for the anchorage or bracing shall be prepared by a registered professional engineer licensed in the State
of Washington.
9: There shall be no occupancy of a building until final inspection has been completed and approved by Tukwila building
inspector. No exception.
10: Remove all demolition rubble and loose miscellaneous material from lot or parcel of ground, properly cap the sanitary
sewer connections, and properly fill or otherwise protect all basements, cellars, septic tanks, wells, and other
excavations. Final inspection approval will be determined by the building inspector based on satisfactory completion of
this requirement.
11: Manufacturers installation instructions shall be available on the Job site at the time of inspection.
12: Water heaters shall be anchored or strapped to resist horizontal displacement due to earthquake motion. Strapping shall
be at points within the upper one -third and lower one -third of the water heater's vertical dimension. A minimum
distance of 4- inches shall be maintained above the controls with the strapping.
13: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the Cityof Tukwila
Permit Center.
14: All electrical work shall be inspected and approved under a separate permit issued by the Washington State Department
of Labor and Industries (206/248- 6630).
doc: Conditions
D06 -325 Printed: 09 -29 -2006
CITY OF TUI(V!P A
PEPT CF CO;.II2WIFTY DaTICT '
6300 SIJUTik :N1L c
TUKWIt..A,WA £1b3
16: ***FIRE DEPARTMENT CONDITIONS * **
PERMIT CENTER
15: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of,
any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits
presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila
shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the
Building Official from requiring the correction of errors in the construction documents and other data.
17: The attached set of building plans have been reviewed by the Fire Prevention Bureau and are acceptable with the
following concerns:
18: The total number of fire extinguishers required for an ordinary hazard occupancy with Class A fire hazards is
calculated at one extinguisher for each 1,500 sq. ft. of area. The extinguisher(s) should be of the "All Purpose" (2A,
20B:C) dry chemical type. Travel distance to any fire extinguisher must be 75' or less. (IFC 906.3) (NFPA 10, 3 -2.1)
19: Portable fire extinguishers, not housed in cabinets shall be installed on the hangers or brackets supplied. Hangers or
brackets shall be securely anchored to the mounting surface in accordance with the manufacturer's installation
instructions. Portable fire extinguishers having a gross weight not exceeding 40 pounds (18 kg) shall be installed so
that its top is not more than 5 feet (1524 mm) above the floor. Hand -held portable fire extinguishers having a gross
weight exceeding 40 pounds (18 kg) shall be Installed so that its top is not more than 3.5 feet (1067 mm) above the
floor. The clearance between the floor and the bottom of the installed hand -held extinguishers shall not be less than 4
inches (102 mm). (IFC 906.7 and IFC 906.9)
20: Fire extinguishers shall not be obstructed or obscured from view. In rooms or areas in which visual obstruction cannot
be completely avoided, means shall be provided to indicate the locations of the extinguishers. (IFC 906.6)
21: Extinguishers shall be located in conspicuous locations where they will be readily accessible and immediately available
for use. These locations shall be along normal paths of travel, unless the fire code official determines that the
hazard posed indicates the need for placement away from normal paths of travel. (IFC 906.5)
22: Fire extinguishers require monthly and yearly inspections. They must have a tag or label securely attached that
indicates the month and year that the inspection was performed and shall identify the company or person performing the
service. Every six years stored pressure extinguishers shall be emptied and subjected to the applicable recharge
procedures. If the required monthly and yearly inspections of the fire extinguisher(s) are not accomplished or the
inspection tag is not completed, a reputable fire extinguisher service company will be required to conduct these
required surveys. (NFPA 10, 4 -3, 4-4)
23: Egress doors shall be readily openable from the egress side without the use of a key or special knowledge or effort.
(IFC 1008.1.8.3 subsection 2.2)
24: Dead bolts are not allowed on auxiliary exit doors unless the dead bolt is automatically retracted when the door handle
is engaged from inside the tenant space (IFC Chapter 10)
25: Door handles, pulls, latches, locks and other operating devices on doors required to be accessible by Chapter 11 of the
International Building Code shall not require tight grasping, tight pinching or twisting of the wrist to operate. (IFC
1008.1.8.1)
26: Exit hardware and marking shall meet the requirements of the International Fire Code. (IFC Chapter 10)
27: Exits and exit access doors shall be marked by an approved exit sign readily visible from any direction of egress
travel. Access to exits shall be marked by readily visible exit signs in cases where the exit or the path of egress
travel is not immediately visible to the occupants. Exit sign placement shall be such that no point in an exit access
corridor is more than 100 feet (30,480 mm) or the listed viewing distance for the sign, whichever is less, from the
nearest visible exit sign. (IFC 1011.1)
doc: Conditions
D06 -325 Printed: 09-29 -2006
CITY OF TUKWDA �
DEPT. OF CO? MU;:ITY DEV1 I.QPt`QT
6300 SOUTHC::N i L 'vi).
TUKWILA, WA 9's1
PERMIT CENTER
28: Every exit sign and directional exit sign shall have plainly legible letters not less than 6 inches (152 mm) high with
the principal strokes of the letters not less than 0.75 inch (19.1 mm) wide. The word "EXIT" shall have letters having
a width not less than 2 inches (51 mm) wide except the letter "I ", and the minimum spacing between letters shall not be
less than 0.375 inch (9.5 mm). Signs larger than the minimum established in section 1011.5.1 of the International Fire
Code shall have letter widths, strokes and spacing in proportion to their height. The word "EXIT" shall be in high
contrast with the background and shall be clearly discernible when the exit sign illumination means is or is not
energized. If an arrow is provided as part of the exit sign, the construction shall be such that the arrow direction
cannot be readily changed. (IFC 1011.5.1)
29: Exit signs shall be illuminated at all times. To ensure continued illumination for a duration of not less than 90
minutes in case of primary power loss, the sign illumination means shall be connected to an emergency power system
provided from storage batteries, unit equipment or on -site generator. (IFC 1006.1, 1006.2, 1006.3)
30: Means of egress, including the exit discharge, shall be illuminated at all times the building space served by the means
of egress is occupied. The means of egress illumination level shall not be less than 1 foot - candle (11 lux) at the
floor level. The power supply for the means of egress illumination shall normally be provided by the premise's
electrical supply. In event of a power failure an emergency power system shall provide power for a duration of not less
than 90 minutes and shall consist of storage batteries, unit equipment or on -site generator. (IFC 1006.1, 1006.2,
1006.3)
31: Maintain sprinkler coverage per N.F.P.A. 13. Addition /relocation of walls, closets or partitions may require relocating
and /or adding sprinkler heads. (IFC 901.4)
32: Sprinklers shall be installed under fixed obstructions over 4 feet (1.2 m) wide such as ducts, decks, open grate
flooring, cutting tables, shelves and overhead doors. (NFPA 13- 8.6.5.3.3)
33: All new sprinkler systems and all modifications to existing sprinkler systems shall have fire department review and
approval of drawings prior to installation or modification. New sprinkler systems and all modifications to sprinkler
systems involving more than 50 heads shall have the written approval of the W.S.R.B., Factory Mutual, Industrial Risk
Insurers Kemper or any other representative designated and /or recognized by the City of Tukwila, prior to submittal to
the Tukwila Fire Prevention Bureau. No sprinkler work shall commence without approved drawings. (City Ordinance #2050)
34: An approved manual fire alarm system is required for this project. The fire alarm system shall meet the requirements of
Americans With Disabilities' Act (I.B.C.), N.F.P.A. 72 and the City of Tukwila Ordinance #2051.(Fire alarm system
notification appliances to also be tied into sprinkler waterflow activation.)
35: All new fire alarm systems or modifications to existing systems shall have the written approval of The Tukwila Fire
Prevention Bureau. No work shall commence until a fire department permit has been obtained. (City Ordinance #2051) (IFC
104.2)
36: An electrical permit from the Washington State Department of Labor and Industries is required for this project.
37: All electrical work and equipment shall conform strictly to the standards of the National Electrical Code. (NFPA 70)
38: New and existing buildings shall have approved address numbers, building numbers or approved building identification
placed in a position that is plainly legible and visible from the street or road fronting the property. These numbers
shall contrast with their background. Address numbers shall be Arabic numbers or alphabet letters. Numbers shall be a
minimum of 4 inches (102mm) high with a minimum stroke width of 0.5 inch (12.7mm). (IFC 505.1)
39: Contact The Tukwila Fire Prevention Bureau to witness all required inspections and tests. (City Ordinances #2050 and
#2051)
40: Any overlooked hazardous condition and /or violation of the adopted Fire or Building Codes does not imply approval of
doc: Conditions 006 -325 Printed: 09 -29 -2006
CITY OF TUKWP A
DEP7. OF CG ... G CITY DLA'r G( >PI tJT
630Tu WILAWAT VD.
98188
such condition or violation.
41: These plans were reviewed by Inspector 511. If you have any questions, please call Tukwila Fire Prevention Bureau at
(206)575 -4407.
42: ** *PUBLIC WORKS DEPARTMENT CONDITIONS * **
43: THE PROPERTY OWNER SHALL APPLY FOR A SEPARATE PUBLIC WORKS TYPE C PERMIT TO INSTALL A REDUCED
PRESSURE PRINCIPLE
ASSEMBLY (RPPA)
ON DOMESTIC WATER SERVICE AND REPLACE SINGLE CHECK WITH DDCVA ON FIRE PREVENTION LINE INCLUDING NE
STORZ CONNECTIONS
FOR THE FDC.
THE ABOVE BACKFLOWS SHALL BE INSTALLED , TESTED AND INSPECTED BY PUBLIC WORKS BY DECEMBER 12, 2006.
APPLICANT HAS
POSTED A $60,000.00 DEPOSIT IN LIEU OF A BOND AND AGREED TO HAVE THEM IN PLACE BY 12/12/2006.
44: ** *PLANNING CONDITIONS * **
PERMIT CENTER
45: The applicant has noted that the mezzanine area is to be abandoned in order to achive minimal parking requirements. The
applicant shall record a notice on the property with the King County Recorders Office. The language of the notice shall
be approved by the City of Tukwila DCD.
46: In order to meet minimum parking design standards, the non ADA parking stalls located in the front of the new ramp
shall be designed as compact.
doc: Conditions
* *continued on next page **
1D06 -325 Printed: 09-29 -2006
CITY OF TUKWPA
DEPT. OF CO. S.Ut:{TY DELTLOPMENT
6300 SLUTH•HCL:N i ER CLVD.
TUKWILA, WA 93183
I hereby certify that I have read these conditions and will comply with them as outlined. All provisions of law and ordinances
governing this work will be complied with, whether specified herein or not.
The granting of this permit does not presume to give authority to violate or cancel the provision of any other work or local laws
regulating construction or the pe ormance of work.
Signature: Date: ZA_1 1 7(2__G_
Print Name:
doc: Conditions
PERMIT CENTER
D06 -325 Printed: 09 -29 -2006
Site Address: 1 20 1 TsRCMS- fog ` li r
Tenant Name:
Property Owners Name:
Mailing Address: IZfl
CONTACT PERSON
CITY OF TUKWILA
Community Development Department
Public Works Department
Permit Center
6300 Southcenter Blvd., Suite 100
Tukwila, WA 98188
http:llwww.ci.tukwila. wa. us
Name: u1 Yyr 1e 1, -
Mailing Address: F l i0 b`{ V F. It OLP
E -Mail Address: d bell Ie Q cl hie Ann • cam
Company Name: 1012
ARCHITECT OF RECORD — Ml plans must be wet stamped by Architect of Record
Company Name: at ttLE
0D he � fr
Mailing Address: f O
Contact Person: ' 10 , re
E -Mail Address: 4k W IG O d ke hk'4or h .Cowl
Company Name: Vik
Mailing Address:
City
Contact Person: Day Telephone:
E -Mail Address: Fax Number:
Qmstom&tTam«Applic.ttioro on woman Permit Applimdo.Aoc
naiad: 4-2006
Db
w
TUKWILA
Building Permit No. 1740 J0 - �L5
Mechanical Permit No.
Plumbing/Gas Permit No.
Public Works Permit No.
Project No
(For office use only)
Applications and plans must be complete in order to be accepted for plan review.
Applications will not be accepted through the mail or by fax.
"Please Print"
SITE LOCATION
King Co Assessor's Tax No.: 30Z VA4 - clot -0
Suite Number. A.2. Floor,
New Tenant: IS Yes , ❑..No
State
jDaay,µ�Ter 3 •
lephone: WIO"C it j
%G�FM►� Wlb •
city �M slam
Fax Number._ Db • 24& 4347q
GENERAL CONTRACTOR INFORMATION —
(Contractor Information for Mechanical (pg 4) for Plumbing and Gas Piping (pg 5))
Mailing Address:
City
Contact Person: Day Telephone:
E -Mail Address: Fax Number.
Contractor Registration Number: Expiration Date:
Sum
City Sum /� Zip
Day Telephone: �� h' C/ 1
Fax Number/024 & • Bstei
ENGINEER OF RECORD — All plans must be wet stamped by Engineer of Record
State
zi
Zip
Zip
Page 1 of 6
BUILDING PERMIT INFORM)SION — 206-431 -3670
Valuation of Project (contractor's bid price): $ J� Existing Building Valuation: $4•4 141
Scope of Work (please provide detailed informal ? - eMOUS FA. ' S 6 MD 1 it hgSfire
. 2 a • hts1EU, gag W k ia>,1v.er31a iNs�u NM art
t
J St (bightuoeM 61'
PV'I1M5 w uao Raw-,
Will there be new rack storage? ❑..Yes tiensio (If yes, a separate permit and plan submittal will be required)
Provide All Building Areas in Square Footage Below
PLANNING DIVISION:
Single - family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches)
For an Accessory dwelling, provide the following.
Lot Area (sq ft):1 Floor area of principal dwelling: Floor area for accessory dwelling:
*Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence.
Number of Parking Stalls Provided: Standard: @ Compact: Handicap:
Will there be a change in use? ':...Yes
Q: V,ppl ics io,u6Fwna-Appliaaiac Oa Laa1/23-2 W 6 - Pami, MTI icetioodoc
AL-4d: 4-2006
bb
El -No If "yes ", explain: itl04 gMEN01,1.5e (Off &
euix Mau. (6rt40•4)
FIRE PROTECTION/HAZARDOUS MATERIALS:
v .. Sprinklers ❑..Automatic Fire Alarm ❑..None ❑..Other (specify)
Will there be storage or use of flammable, combustible or hazardous materials in the building? ❑.. Yes No
If "yes", attach list ofmaterials and storage locations on a separate 8 -1 /2x 11 paper indicating quantities and Material Sa ety Data Sheets.
SEPTIC SYSTEM:
❑ On -site Septic System - For on -site septic system, provide 2 copies of a current septic design approved by King County Health
Department.
Page 2 of
PERMIT APPLICATION NOTES — Applicable to all permits in this application
Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject
to possible revision by the Permit Center to comply with current fee schedules.
Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation.
Building and Mechanical Permit
The Building Official may grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be
requested in writing and justifiable cause demonstrated. Section 105.31 International Building Code (current edition).
Plumbing Permit
The Building Official may grant one extension of time for an additional period not exceeding 180 days. The extension shall be requested
in writing and justifiable cause demonstrated. Section 103.4.3 Uniform Plumbing code (current edition),
I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER
PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT.
BUILDING
Signature
Print Name ‘r2 /AIL, }�', t
Mailing Address: (Z T Zb • + LGI✓fai �• %I tO
Date Application Expires:
Date Application Accepted
HORIZED AGENT:
Oj 1 j ur
Q0Apgicaiw•V'mnHAauimiou On uneV -z0b6 • pamii Applicadotdoc
R•vvcd 42006
bh
Date: t t
Day Telephone: ' 1.'0' 4 35%s
t$ Ia
City State Tip
Page 6 of 6
Doc: RECSETS -08
RECEIPT NO: R06 -01773
Initials: JEM
User ID: 1165
Payee: WACO ENTERPRISES
SET TRANSACTIONS:
Set Member Amount
D06 -335
TOTAL:
ACCOUNT ITEM LIST:
Description
PLAN CHECK - NOSHES
City of Tukwila
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206-431-3670
Fax: 206 -431 -3665
Web site: http: //wwv.ci.tukwila.wa.us
SET RECEIPT
SET ID: 1106 SET NAME: D06 -325 & 338
58.00
58.00
58.00
Payment Date: 11/06/2006
Total Payment: 116.00
TRANSACTION LIST:
Type Method Description Amount
Payment Check 3415 116.00
TOTAL: 118.00
Account Code Current Pmts
000/345.830
TOTAL:
116.00
118.00
1502 11/07 9716 TOTAL 116.00
ACCOUNT ITEM LIST:
Description
Current Pmts
City of Tukwila
6300 Southcenter BL, Suite 100 / Tukwila, WA 98188 / (206) 431 -3670
Parcel No.: 3523049092 Permit Number: D06 -325
Address: 1205 ANDOVER PK W TUKW Status: APPROVED
Suite No: Applied Date: 08/21/2006
Applicant: QUILTING AND SEWING OUTLET Issue Date:
Receipt No.: R06 -01537 Payment Amount: 664.76
Initials: JEM Payment Date: 0912912006 12:09 PM
User ID: 1165 Balance: 50.00
Payee: WACO ENTERPRISES
TRANSACTION LIST:
Type Method Description
Amount
Payment Check 3392 664.76
BUILDING - NONRES
STATE BUILDING SURCHARGE
RECEIPT
Account Code
000/322.100 660.26
000/386.904 4.50
Total: 664.76
0245 09/29 9716 TOTAL 664.76
doc: Receipt Printed: 09-29 -2006
City. of t'ukwila
6300 Southcenter BL, Suite 100 / Tukwila, WA 98188 / (206) 431 -3670
Parcel No.: 3523049092 Permit Number: D06 -325
Address 1205 ANDOVER PK W TUKW Status: PENDING
Suite No: Applied Date: 08/21/2006
Applicant: QUILTING & SEWING OUTLET Issue Date:
Receipt No.: R06 -01403 Payment Amount: 60,000.00
Initials: BLH Payment Date: 09/08/2006 10:07 AM
User ID: ADMIN Balance: 5664.76
Payee: WACO ENTERPRISES
TRANSACTION LIST:
Type Method Description
Amount
RECEIPT
Payment Check 3380 60,000.00
ACCOUNT ITEM LIST:
Description
Current Pmts
BUILDING BOND /DEPOSIT
Account Code
000/386.908 60,000.00
Total: 60,000.00
9437 09/08 9710 TOTAL 60000.00
doc: Receipt Printed: 09-08-2006
City of Tukwila
6300 Southcenter BL, Suite 100 / Tukwila, WA 98188 / (206) 431 -3670
Parcel No.: 3523049092 Permit Number: D06 -325
Address: 1205 ANDOVER PK W TUKW Status: PENDING
Suite No: Applied Date: 08/21/2006
Applicant: QUILTING & SEWING OUTLET Issue Date:
Receipt No.: R06 -01308 Payment Amount: 429.17
Initials: JEM Payment Date: 08/21/2006 12:26 PM
User ID: 1165 Balance: 5664.76
Payee: DAVID E. KEHLE ARCHITECT
TRANSACTION LIST:
Type Method Description
Amount
RECEIPT
Payment Check 17486 429.17
ACCOUNT ITEM LIST:
Description
Current Pmts
PLAN CHECK - NONRES
Account Code
000/345.830 429.17
Total: 429.17
8856 08/21 9716 TOTAL 429.17
doc: Receipt --- - Printed: 08 -21 -2006
Proj
C17///1, A" Fin./ /Sett//n,
Type of Inspection:
///1_/9/
`f
Adddess:
/J Ds t'- varair2 ).0 !1/
Date Called:
Special Instructions:
Date Wanted:
6, - /e / - a - 7
N,
Requester:
Phone No:
a c6 -C/z7 V32 /
INSPECTION RECORD
Retain a copy with permit
INSPE • NO.
CITY OF TUKWILA BUILDING DIVISION
6300 Southcenter Blvd., #100, Tukwila, WA 98188
(206)431 -3,67
/ R I Approved per applicable codes. El Corrections required prior to approval.
COtIMENTS:
oi )7te
Inspect
eel ;4 INSPECTION
$
pa `F 6300 Southcente
'Receipt No.:
4 - 7 te:6 /i/g7
REQUIRED. Prior o inspection, fee must be
lvd.. Suite 100. Call the schedule reinspection.
'Date:
COMMENTS:
`
•
A ')19 ,gg /l /•v(, — 5 t4 //s A/C
Called:
fie n/ 2 /
Special Instructions:
Date Want d:
/.2 � ?rn
/3 / /3.✓/✓ /ir/O
`, 4./4/ Aict4 Grp`
3�
/-2 , r! r. -v.4 / A/ Gt e- / o A •
I
Project: -
0Z ./` I 7j.(/% if S�Wi,t/
Type of Inspection:
j zriit/4 /
•
Address: /Date
/2 0.1 . <44./L)thi Q a Lc/
Called:
Special Instructions:
Date Want d:
/.2 � ?rn
/�C m.
(p•
Requester:
Phone No:
,20C, X127 -4 (.3 2 /
°Approved per applicable codes.
paid at 6300 Southcenter Blvd., Sul
- INSPECTION RECORD
Retain a copy with permit
ON NO.
CITY OF TUKWILA BUILDING DIVISION
6300 Southcenter Blvd., #100, Tukwila, WA 98188
PER
(206)431 -3
Corrections required prior to approval. ID
(Date:
58.00 REINSPECTION FEE • I(EQUIREDArior to inspection, fee must be
100. Call to sechedule reinspection.
Receipt No.:
'Date:
Pratt:
Type of Inspection:
A�dress:
/20 5
'.v f Pk w
Date Called:
Special Instructions:
Date Wanted:
// — /4C OG
a.m.
P.m.
Requester:
Phone No:
INSPECTION RECORD
Retain a copy with permit
INSPECT(' NO.
CITY OF TUKWILA BUILDING DIVISION
6300 Southcenter Blvd., #100, Tukwila, WA 98188
/)9 32
' yl Approved per applicable codes. EJ Corrections required prior to approval.
COMMENTS:
Tirol n l 4 XI/S � cOi/
II-2J— 04
a ( - ea , -, /t s A- » -,. fr), ni
/�_, -t, ,c/,�. ors,. 4;r
h j /ier S4./A.
s f"
Inspector:
Date: /iv
! v`
$58.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be
paid at 6300 Southcenter Blvd., Suite 100. Call to sechedule reinspection.
(Receipt No.:
Date:
Project:
'1 7 i�)>L-
Type f nspection:
s«,7,.( ,,
G/i.
es
Addr
ate Called: ��JJ
> re P
Special Instruction :
Date Want : d
�l
y — o'
?.
Request r:
Phone No:
INSPECTION RECORD
Retain a copy with permit
INSPECTION NO.
CITY OF TUKWILA BUILDING DIVISION
l 7t l Approved per applicable codes.
PER
6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431.3Q7
El Corrections required prior to approval.
COMMENTS:
$58.0 EINSPECTIOPVFEE REQUIRED. Prior to inspection, fee must be
paid at 6300 Southcenter Blvd., Suite 100. Call to sechedule reinspection.
Receipt No.:
'Date:
Pro'ect:
Type of Inspection: ,
Address: I (
12 6,0 w K i t1
Date Called:
1t /I
Special Instructions:
Date Wanted:
,
ii /It�6
P.m,
Requester:
Phone No:
Approved per applicable codes.
INSPECTION RECORD
Retain a copy with permit
DL1, - ;ZS
INSPECTION NO.
CITY OF TUKWILA BUILDING DIVISION
6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670
PERMIT NO.
El Corrections required prior to approval.
COMMENTS:
(VOL - Vo--(/LJ -/ D (A LA y 1 c
P Lt h � ,L�Jb L.J( - 1.1< t
9.
e
(�ul�
P tikk III h 9'tl peki c ct
i
(r1
J
Inspector:
Date: ,I /( il /U1
ri $58.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be
paid at 6300 Southcenter Blvd., Suite 100. Call to sechedule reinspection.
Receipt No,:
!Date:
Project:
Type of Inspection:
Addres
i' //f�'
Date ailed:
Spec�
In
Date Wanted:
"
/O-`"
�`
'C
Requester:
Phone No:
Z
INSPECTION RECORD
Retain a copy with permit
INSPECTION N0.
CITY OF TUKWILA BUILDING DIVISION
6300 Southcenter Blvd., #100, Tukwila, WA 98188 /(
PERMIT NO.
6)431-3
)43 1 -3[0
A pproved per applicable codes. EJ Corrections required prior to approval.
COMMENTS:
I Date lh
I $58. . REINSPECTION F e REQUIRED. Prior to inspection, fee must be
paid at 6300 Southcenter Blvd., Suite 100. Call to sechedule reinspection.
Receipt No.:
'Date:
Project: /
' r - / bhi/)1_
Type of Inspection: _
N
/
Addle
izo C /4,4
Date Called:
Special Instructions:
Date Wanted:
10 -11 -0
.m.
Requester:
Phone No:
J
INSPECTION RECORD
Retain a copy with permit
INSPECTION NO.
CITY OF TUKWILA BUILDING DIVISION
6300 Southcenter Blvd., #100, Tukwila, WA 98188
(206)431 =36
0 Approved per applicable codes. Corrections required prior to approval.
COMMENTS:
) c- , 4/ 3reoe
1 *"
Inspecto /11 1
Date j/9- //
$58.00 REINSPECTION'FEE REQUIRED. Prior to inspection, fee must be
paid at 6300 Southcenter Blvd., Suite 100. Call to sechedule reinspection.
Receipt No.:
'Date:
Project: A P ,a_ x /
Sprinklers:
Type of Inspection:
EA t=iNnL
Address: 12 (; -; A
Suite #:
' w / ! "20C /WW
/
Contact Person:
I ->n✓ro Lt/.7ei
Special Instructions:
Occupancy Type:
Phone No.:
C753) &s3 -- &oc
Needs Shift Inspection:
Sprinklers:
Fire Alarm:
Hood & Duct:
Monitor:
Pre -Fire:
Permits:
Occupancy Type:
5
INSPECTION NUMBER
Approved per applicable codes.
INSPECTION RECORD
Retain a copy with permit
Word /Inspection Record Form.Doc 1/13/06
PERMIT NUMBERS
CITY OF TUKWILA FIRE DEPARTMENT
444 Andover Park East, Tukwila, Wa. 98188 206- 575 -4407
Mr Oa 6 - 95 - BOO
n Corrections required prior to approval.
COMMENTS:
r4 r%N4-L- t9
//vg L Gf
Date: i2I 19 lob
Hrs.: 2.
Inspector: a
n $80.00 REINSPECTION FEE REQUIRED. You will receive an invoice from
the City of Tukwila Finance Department. Call to schedule a reinspection.
T.F.D. Form F.P. 113
Project:
5Rcc L)uktdiow`et
Sprinklers:
Type of Inspection:
SI(R E 5P2•uki -c2_ Ceev
Address: ins- A _
Suite #:
Plc Lj
Co ta Person:
v- -e, at- u) ACh#C 2-
Special Instructions: !
1 .
Occupancy Type:
Phone No.:
aoh ' Ifn- 1
Needs Shift Inspection:
Sprinklers:
Fire Alarm:
Hood & Duct:
Monitor:
Pre -Fire:
Permits:
Occupancy Type:
444 Andover Park East ukwila, Wa. 98188 206 - 575 -4407
1 1
INSPECTION
.Approved per applicable codes
INSPECTION RECORD
Retain a copy with permit
CITY OF TUKWILA FIRE DEPARTMENT
COMMENTS:
6 vi - b C_eiv
SPR•askl-c 1.J4L
Inspector: g\
Date: /r /0o 6,
Hrs.: /
$80.00 REINSPECTION FEE REQUIRED. You will receive an invoice from
the City of Tukwila Finance Department. Call to schedule a reinspection.
Word /Inspection Record Form.Doc
1/13/06
06— s- )v
bo 6 • a s'
PERMIT NUMBERS
n Corrections required prior to approval.
T.F.D. Form F.P. 113
May 09 07 06:02a CASCADE TESTING
May S, 2007
Cert No. 0611 -06
City of Tukwila Building Department
6300 Southcenter Boulevard, Suite 100
Tukwila, Washington 98188
Attention:
Reference:
Dear Mr. Larson:
Respectfully,
D.ASCA'-DE TESTING
1LF1111•,17-. f Y 4SF:±(2.T101-4
12915) N.E. 126TI-. FLP.Cb
I41FK_AND, WASHINGTON 98034
Dave Larson
Pieper Short Plat Detention Vault
17083 53 Ave South
Permit No. D06 -326
This is to advise you that the following inspections were completed per our reports for the above
referenced project and permit. Please see our enclosed reports for actual details of the inspections
performed.
Reinforced concrete for footings, slab on grade, walls and lid for detention vault
All inspections, only as inspected and reported, conformed to Tukwila Building and Land
Development approved plans, specifications, UBC/IBC and related codes and/or verbal or written
instructions from the Engineer of Record.
CASCADE TESTING LABORATORY, INC.
Kenneth B. Foot
President
425- 823 -2203
L.ABORA-O``'. INC.
p.2
KIHICLAND: (426) S2S -9800 SEATTLE: (200; 525 -0700
FAX: (425) E23.2202 EVERET`: (42S) 259 -0257
RECEIVED
MAY 0 9 2007
COMMUNITY
DEVELOPMENT
November 1, 2006
WACO Enterprises
P.O. Box 88216
Tukwila WA. 98138 -2216
Mr. Brandon Miles, Planner
Department of Community Development
City of Tukwila
6300 Southcenter Blvd.
Tukwila Wa. 98188
King County Recorders Office
500 4' Avenue #311
Seattle WA. 98104
Re: Tax Parcel No. 352304- 9092 -08
Legal description Attached
Permit No. DO6 -325, Sept. 29,2006; Quilting and Sewing Outlet
Dear Mr. Miles,
WACO Enterprises is developing its property at 1205 Andover Park West, Tukwila, WA. It will
be occupied by two bulk retail tenants as described in Permits DO6 -325 and DO6 -335. This
change of use requires 53 parking spaces, which are currently available on the site.
To achieve this parking it is necessary to abandon 5692 square feet of mezzanine This space had
been used as office space. Now this mezzanine will not be used and abandoned as specified in
Permit DO6 -325.
D.Wachter, Partner
WACO Enterprises
SEE REVERSE SIDE
PROPERTY TAX RP1O
ACCOUNT NUMBER
352304- 9092 -08
277134A
BRING ALL PARTS WHEN PAYING IN PERSON
- -- WACO ENTERPRISE
- -- 1205 ANDOVER PARK W
TUKWILA WA
KEEP
THIS
PORTION
First hal
by Aq
BECOM
BAAP ON W MGN ANDOVER PK W Interest
I
" 30 FT W 8 731•24 FT S FR NE COR second!
OF NW 1/4 OF NE 1/4 TH S ALG
SD MGN 272.5 FT TH N 87 -55 -02
PROPERTY ADDRESS 01-51-39
05ANDOVE S
RPARKETW 6.
LO'
•
BLOCK ?; .000E SEC '2.111(11P1 RG.Pi
State...]
Local Sp
County
Unincel
Port---- -
Sewer
Library -i
Other .4
Emergei
• Otherl
TOTAL
*OT
98188
31 or
acuuei
WACO Enterprises
P.O. BOX 88216
Tukwila, WA 98138 -2216
WACO Enterprises
P.O. BOX 88216
Tukwila, WA 98138 -2216
I�( o✓ 3 2o0
1D o, t (es -PlatAAArr
of Totic410 , LOA.
P■ - it DO 6 -- 32N 5 - ?j 2 /o 6
1- 1'5 - . Notice )o GiYJc koQoti w
lauyuo approve b7 Oil/
D cnr j f'&Jc,v - P lease- f tie Co ri4 l a t yap
(akc. we cat. use - LL ( - f taw fl 3
LiCVaJctr-r Cc) as3 6 OOS
Project Info
Proieet Address
g e 1► I,_1, —
Date z4 1
1 97'2
k41774 \` - @ttI Al-
For lading Department Use
F?LE COPY
r'-
Covered Parking
(standard paint)
Applicant Name:
Applicant Address:
/ _►'t_ _'7 � _
02 me
�y • n (-. �i. it 0V4 ^far
ApplicaM Phone:
Covered Parking
(reflective paint)
�
I . g#g ....i
Project Description
/
• New Building • Addition ( Alteration
• plans Included
Refer to WSEC Section 1513 for controls and commissioning requirements.
Compliance Option
• Prescriptive 0 Lighting Power Allowance 0 Systems Analysis
(See Qualification Checldist (over). Indicate Prescriptive & LPA spaces dearly on plans.)
Alteration Exceptions
(check appropriate box - sec. 1132.3)
0.2 W/R2
4 No changes are being made to the lighting
• Less than 60% of the fixtures new, installed wattage not increased, & space use not changed.
Location
Fixture Description
E FR O
Watts/
Fixture
Allowed Watts
per ft or per If
Area in it Allowed
(or If for perimeter)
Watts
x R (or x If)
Covered Parking
(standard paint)
CODE C
a.
02 me
Covered Parking
(reflective paint)
C 2 8 2f1118
/
0.3 Wm2
CITY
RECEIVED
OF TLKWfU
Open Pa.dng
0.2 W/R2
Outdoor Areas
AA
0.2 wnt2
A
b b 2 1 2006
Bldg. (by facade)'
C) II Of Tukwila
0.25 W /1t'
rtRA,df
Bldg. (by semi'
nt till limit` f1Tt /Tr Tl1hl
7.5 W/lf
r LrNTER
Location
Fixture Description
Number of
Tortures
Watts/
Fixture
Watts
Proposed
a.
ro�
Location
(floor /room no.)
Occupancy Description
Allowed
Watts per 11
Area in 19
Allowed x Area
" From Table 15-1 (over) - document all exceptions on fonh LTG -LPA Total Allowed Watts
Location
(Boor /room no.)
Fixture Description
Number of
Fixtures
Watts/
Fixture
Watts
Proposed
Total Proposed Watts may not exceed Total Allowed Watts for Interior Total Proposed Watts
2004 Washington State Nonresidential Energy Code Compliance Form
Lighting Summary
LTG -SUM
2004 Washington State Nonnnidentat Energy Code Compliance Forms
Maximum Allowed Lighting Wattage (Interior
Notes:
1. Use manufacturer's listed maximum input wattage. For hard -wired ballasts only,
the default table in the NREC Technical Reference Manual may also be used
2. Include exit lights unless less than 5 watts per fbdure.
Proposed Lighting Wattage (Interior) 3. List ad fixtures. For exempt lighting, not exception and leave Watts/Fixture blank.
Maximum Allowed Lighting Wattage (Exterior
1. Choose either the facade area or the od, bud iI& boti) Total Allowed Watts
Use mrgr listed ma omum input wattage. I-or fixtures with hard - es t?a30113
default tablerti the NREC Technical Reference Manual may also be used.
Proposed Lighting Wattage (Exterior)
Total Proposed Watts may not exceed Total Allowed Watts for Exterior
otal Proposed W
Rene* Mw 2005
Sent By: HUDSON & ASSOCIATES; 2063246248; Aug -15 -08 18:10; Page 2/4
RICHARD HUDSON & ASSOCIATES, INC. X
CONSULTING ENGINEERS snen of I
1605 12TH AVENUE • SUTTE 18
SEATTLE, WASHINGTON 98122 mammon R DM 8 '—(5.042_
206-324-6160 • Fax 206- 324 -6248
rhudson @hudsonenglneera.cam
N.+AA-1 O vs( hasof 9o
e as vmid
ft Vi &Petah
4.001..a.41‘41,4 = • 73 r 7
NAQ DyCPn • inc.
I
Sec-An-al P(o
AAA She Tried 64 c�
c }r wvr. of L6A O( S .r„ sc. cC
art ‘,IC.) ft):
Is p sf
P antik at fluc4r't1 -r) s La-A
REVIEWED FOR
CODE COMPLIANCE
A nnnnuCll
SEP 2 8 2006
C A Of Tukwila
fUILOINC OTVISTONi
/ l; 12.2:2;.
I SO 1SD
otfer?'
. ' 2
RECEIVED
CITY OF TUKWLA
AUG 2 1 2006
PERMIT CENTER
PO(o415
Sent By: HUDSON & ASSOCIATES;
2063248248;
Aug -15 -06 16:10; Page 3/4
DPENING
T.S. 4 xV
EXISTING PANEL
FIELD VERIFY BOTTOM OF
STRUCTURE ELEVATION
VIEWED FROM INSIDE LOOKING OUT
IONAL'
NEW DOOR OPENING AT
APTEX
TEL (206) 324 -6180
FAX (206) 324 -6248
RICHARD HUDSON
& ASSOCIATES, INC.
CONSULTING ENGINEERS
DATE: 8 -15 -06
SHEET NO.:
c �1
`� — I
OF 2
Sent By: HUDSON & ASSOCIATES;
2063248248;
Aug -15 -06 16:10; Page 3/4
DPENING
T.S. 4 xV
EXISTING PANEL
FIELD VERIFY BOTTOM OF
STRUCTURE ELEVATION
VIEWED FROM INSIDE LOOKING OUT
Sent By: HUDSON & ASSOCIATES;
tt
SAW CUT
R 36x4x1 1 -1"
/2 -3/4"93 EXP. BOLTS
W /3" EMBEDMENT
T.S. COL.
RE: ELEVATION
SECTION A -2
SCALE: 34" N. 1' -0"
12"
DOOR OPENING COL
£ 1x8x1' -1"
W /2 -%'t "0 EXP. BOLTS
W /3" EMBEDMENT
T.S. COL.
RE: ELEVATION
SECTION B -2
SCALE: W - 1' -0"
TEL (206) 324 -6160
FAX (206) 324 -6248
RICHARD HUDSON
& ASSOCIATES, INC.
CONSULTING ENGINEERS
2083248248; Aug -15 -06 16:11; Page 4/4
12"
« COL. I EXISTING
PANEL
EXISTING
PANEL
NEW DOOR OPENING AT
APTEX
DATE: 8 -15 -06
SHEET NO.:
S -2
OF 2
05-07 -2007
DAVID KEHLE
1916 SONATA DR SW
SEATTLE WA 98116
RE: Permit No. D06 -325
1205 ANDOVER PK W TUKW
Dear Permit Holder:
In reviewing our current records the above noted permit has not received a final inspection by the City of Tukwila Building Division.
Per the International Building Code and/or the International Mechanical Code, every permit issued by the Building Division under the
provisions of this code shall expire by limitation and become null and void if the building or work authorized by such permit is not
commenced within 180 days from the date of such permit, or if the building or work authorized by such permit is suspended or
abandoned at any time after the work is commenced for a period of 180 days.
Based on the above, you are hereby advised to:
Call the City of Tukwila Inspection Request Line at 206 - 431 -2451 to schedule for the next or final inspection-
This inspection is intended to determine if substantial work has been accomplished since issuance of the permit or last inspection; or if
the project should be considered abandoned.
If such determination is made, the Building Code does allow the Building Official to approve one or more extensions of time for
additional periods not exceeding 90 days each. Extension requests must be In writing and erovide satisfactory reasons why
circumstances beyond the applicants control have prevented action from being taken.
In the event you do not call for the above inspection and receive an extension prior to 06/17/2007 , your permit will become null and
void and any further work on the project will require a new permit and associated fees.
Thank you for your cooperation in this matter.
Sincerely,
fer Marshall,
Permit Technician
xc: Permit File No. D06 -325
City of Tukwila
Steven M. Mullet, Mayor
Department of Community Development Steve Lancaster, Director
6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone: 206 - 431 -3670 • Fax: 206 - 431 -3665
January 23, 2007
WACO Enterprises
PO Box 88216
Tukwila, WA 98138
RE: Refund
WACO Enterprises —1205 Andover Pk W -(D06 -325)
Dear Sir:
Enclosed please find a check in the amount of' $60,000.00 for the installation of a RPPA on the domestic
water and DDCVA for the fire line for the above referenced project. This work has been installed and the
City Public Works Department Inspector has approved the installation.
If you should have any questions, please contact our office at (206)431 -3672.
Sincerely,
464.hdle
Brenda Holt
Permit Coordinator
encl /
xc: Permit No. D06 -325'
Department of Community Development Steve Lancaster, Director
H:1Documentslaond Release 1D06 -325 - Refund LetterDOC
bh
Steven M. Mullet, Mayor
6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone: 206-431-3670 • Fax: 206-431-3665
Memo
Jaruay16,2006
To: Laurie Anderson
From: Brenda Holt
Re: D06 -325
City of Tukwila
Permit Center
Please refund $60,000.00 to WACO Enterprises. The installation of the RPPA on domestic
water and DDCVA for fire line have been installed and inspected by the Public Works
Department. Please make the check out to:
WACO Enterprises
PO Box 88216
Tukwila, WA 98138
Please send the check to my attention and I will forward it to them. Thank you.
Xc: File No. D06 -325
Q:icocumentsSBond ReleaseSDOe -325 • Refund Memo.doc
Section 1— to be completed by Developer
Name of Development: i .1 & 1r 0 U IL.T1N 2 -S I N/i Date: -
Address: 11205 fliW)O&E - Pie , i- , sr Permit No.: Oro - 325
Name: fl44(v n Nt�1
Address: r'y I. .2 / C, • c,
City/State/Zip ,A (L)a. p X 3e •
Description of items to be completed (reference plans/documents where items are described)
IA) ST7) /- A9T7oA OF A RPM7 Div Do,cis STIR GJ/5 -C.p
ANn /J n r /,'g ,1 ,,t F /,6 /. //v6 /NCt ceD /N6 F.Dc
Release should be sent to:
MOD /not T/OAJ
City of Tukwila
6300 Southcenter Blvd, Suite 100
Tukwila, WA 98188
206 -431 -3670
DEVELOPER'S PROJECT WARRANTY REQUEST FORM
As the owner, or autsorized agent of the owner, I hereby submit cash or cash equivalent in the amount of
$ 60 OO(� e- (150 of value to complete work above) and attach s po documentation for value of work. I
will have this work tamed out and call for a final inspection by this date: 2 OC or risk having the City use
these funds to carry out the work with their own contractor or in -hou e man wer. If I fail to carry out the work, I hereby
authorize the City to go onto the property and carry out completo 3 e ./•ve deft further agree to complete
all work listed above prior to requesting inspection and release • � /
Signed: � � n ' , ��• 9 /�0 G.
Title: ia �c ,449 --. . /
Section 2 - to In completed by City staff THIS FUND IS AUTHORIZED TQ BE ACCEPTED'
Signed: 0 1190€444-0 - *St Department Head: ?3' Mts"u��l..)
Amount: $ 6 D, 000'°
9
M'Cash /Check ❑ Cash Assignment ❑ Bond
City Receipt No.: Fi0 -01V05 Received By: b h()/�
Section 4 —to be completed by City staff
Deposited this Dat
Amount Released: $ (PCl 0040
(A Check - Check No. Watt ❑ Cash E uwalent- Letter attached
Date Released: I• Zt • pi Released by:
F.dc r n•ms•r••• trw..lap.'s pra array be
oar: r.ae.n 2003
o(0
I Section 3 — to be completed by Developer
All work identified in Section 1 of this form has now been completed and returned to
department which authorized warranty. I hereby request inspection and release of my
cash/cash equivalent/bond.
Developer's Representative: Date:
To be completed by City staff
I have reviewed the above work and found it acceptable and therefore authorize the release of the above
h equivalent/bond.
Inspecto : .I ( / � Date: / n0 d Authorized By:
❑ Bond - Letter attached
Ms. Joanna Spencer, Development Engineer
City of Tukwila
Department ofPublicWorks
6300 Southcenter Blvd. Suite 100
Tukwila, WA. 98188
RE: Quilting and Sewing Outlet Tenant Improvement
1205 Andover Park West, Tukwila WA
PERMIT No. D06 -325
WACO Enterprises
1205 Andover Park West
Tukwila, WA 98188.
September 7,2006
Dear Ms Spencer:
We have your letter of August 23, 2006 reference Quilting and Sewing Outlet Tenant
Improvement. We are aware of the requirement of installing Backflow Valves on our
Domestic Water and Fire Line.
It is our intent to do this in a reasonable and timely matter. We will proceed to receive
and finalize the bids and advise the Department of the planned completion date.
We opt to install under a separate permit, and not as a revision to the Tenant
Improvement DO6 -325. We request that permit DO6 -325 be granted.
The estimated cost of these items is $36,000; 150% of this is $60,000.after tax. We are
prepared to set aside this sum to warrant that this work will be done. This sum will be
paid to a city trust account, held to pay for the necessary work.
D. Wachter
WACO Enterprises
INCLUDED:
rrom: v.ascaee „farm, Lw io: izuoo 000011
TO: Mr. David Wachter
APTEX, INC.
1205 Andover Park West
Tukwila, WA 98188
rage: vs uate: 0u4tzUU0 0:uu:4r rm
Cascade Alarm'
Since 1919
PO BOX 7459 - KENT, WASHINGTON 98042 - 206 - 767 -5800 - FAX: 253- 630 -4851 -
www.cascadealarrn.com w tqv
m 'T1 �,M, r- c — ✓l ef
I (,thx F I N ilAj,
L�Wc 4s t3
DATE: August 4, 2006 lj M' , ett
QUOTE: $29,790.00 New 8" Double Detector Check Valve 4484 -LA Vault Installation
�cay.AQ Cratln2 106
Le) 39 Lf
CLARIFICATIONS FOR 8 "DOUBLE DETECTOR CHECK VALVE AND VAULT:
Cascade Alarm will provide plans, permits (with the exceptions as noted below), fabrication, equipment, material and
installation for work as listed below. Our price is based upon removing 1-8" Single Check valve assembly and installing a new
8" Double Detector Check Valve assembly ( ifequtprnant is larger than 8" cost will increase) approved w/ by pass with 8"
vtcmanc snot on valves wnn 011111M tamper bwitcnes, new VaUlt m plaCC or exunng vault Miff IS JUSt 10 srna11 rot any mime
check valve assembly with 2 - 3'4" x 3' -0" double hinged doors, install a new ladder, flush, and test per Tukwila Public Works.
1. Install New Concrete Vault # 4484 -LA 9' x 5' x 5'
2. Provide vault lid as per Tukwila requirements w/ 2 - 3'4' double diamond hinged doors or one larger one.
3. Remove all the dirt and mud out of the existing vault and Demo as needed.
4. Take out the existing 8' Single Detector Check valve and install new 8" Double Detector Check Valve with by pass
per Tukwila standards.
5. Certify Backflow Device per Tukwila Water Department as required.
6. Provide new pipe supports under the new DDCV inside existing vault. Provide new pipe support under relocated 6"
existing flanged check valve.
7. Hauling away of existing vault and paying the fee to recycle the vault at Concrete Recycle.
8. We have included flushing and testing as required by Public Works.
9. Pea Gravel is included for under the new vault wider the drain hole to keep mud and water from building up inside
the new vault.
EXCLUSIONS:
tram: l.ascaae Alan, LLL,
inmoi0000u rage: ao Late: W4ILWb aw:zi rm
1. Washington State Sales Tax
2. Integrity of existing pipe, fittings and Boding or lack of and/or code violations to existing systems if not addressed
above.
3. Patching of concrete, asphalt or curbing if needed
4. Environmental Fees or any Overtime inspection fees, right away permits, etc. Electrical Wiring for tamper switches —
Quote is provided by Cascade Alan, LLC (attached)
5. Select Fill if unsuitable or contaminated soils are encountered and/or removal of same.
6. Sump Pump and wiring if required. (Not required per Public Works drawing)
7. Overtime or Shift work
8. Landscaping repair /replacement of.
9. 5^ Stortz adapter in place of existing FD Connections
10. Tampers Switches on 2 existing wall posts indicators,
CASCADE ALARM (FIRE PROTECTION DIVISION) Accepted By:
Roxanne Craine Date:
Service Sales Representative
• SECURITY & FIRE ALARM SYSTEMS - FIRE PROTECTION SYSTEMS - UL CENTRAL STATION MONITORING
*CONFIDENCE TESTING • • 24 HOUR SERVICE - LICENSED, BONDED, INSURED'
"First When Seconds Count"
To: 12065758680 with
From:
Subject:
Message:
Thank you,
Reid Saarlo
Service Sales
Cascade Alarm, LLC
prom: l.ascaoe Alarm, LLI. to: 12UOb /bdboU Page: 1(4 uate: b/4/2W8 b:UU:Lf rM
Cascade Alarm, LLC
PO Box 7459, Kent, WA 98042
(206)- 767 -5800 or (800)333 -9860
Fax 253 - 630 -4851
Email: support@cascadealarm.com
If you have :waived this fax hi error, please destroy this and call 206-767-3804 ant 2 Think you.
************************************************* * * * * * * * * * * * * * * * * * * * * * * * * * * * * * **
FAX TRANSMISSION
" Security, Fire Sprinkler & Fire Alarm Systems, 24/7 Service, Local UL Listed Central Station Monitoring, Certified Inspections & Extinguishers "
rrom: laascaoe , iarm, LL\. 10: 4u00100000
Cascade Alarm'
Since 1979
PO BOX 7459 - KENT, WASHINGTON 98042 - 206- 767 -5800 - FAX: 253- 630 -4851 -
www. cas cadealarm. com
DATE: September 7, 2006
Mr. David Wachter
APTEX, INC.
1205 Andover Park West
Seattle, WA 98188
QUOTE: 54,990.00
rage: uJ tare VI r[WO 0:41 :U/ rm
CLARIFICATIONS FOR THE 1 1/2" Domestic Reduced Pressure Backflow Preventer: Cascade
Alarm will provide design, permits, material, demo of old detector check valve and vault and installation of a
new Reduced Pressure Per Tukwila Standards as follows:
1. Remove the existing single check in the existing vault and redo pipe and fittings as needed.
2. Install a new 1 'h" Reduced Pressure Backflow.
3. Install a new Hot Box per Tukwila Standards.
4. Certify the new Reduced Pressure Backflow Valve per Tukwila Water Department.
5. All work to be performed during normal business hours.
EXCLUSIONS:
1. Washington State Sales Tax
2. Integrity of existing pipe, fittings and rodding or lack of, and/or code violations to existing systems
if not addressed above.
3. Select Fill if unsuitable or contaminated soils are encountered and/or removal of same.
4. Overtime or Shiftwork (Normal hours are lam to 3:30pm, Monday thru Friday) or Any Overtime
inspection fees from Tukwila Public works department if work not performed during normal hours.
5. Landscaping repair or replacement of same.
6. 120V Electrical Wiring for the Hot Box (We are not a high voltage electrical company).
CASCADE ALARM (FIRE PROTECTION DIVISION) Accepted By:
Roxanne Craine Date:
Service Sales Representative
SECURITY & FIRE ALARM SYSTEMS - FIRE PROTECTION SYSTEMS - UL CENTRAL STATION MONITORING -
CONFIDENCE TESTING •
• 24 HOUR SERVICE - LICENSED, BONDED, INSURED *
"Fast When Seconds Count"
rrom: Lascaae Alarm, LLt. lo: ZUDD /DtWaU rage: ;11:1 uate: 11///1000 D:41:U/ rm
Our quote wM remain In effect for 30 days, after which It will be subject to our review. This proposal Is subject to
approval by Local Authority Having Jurisdicilon. By accepting this quotation purchaser agrees to Cascade Alarm's tams &
conditions.
Message:
Mr. David Wachter
Thank you,
CASCADE ALARM, LLC
Roxanne Craine
(206)767 -5800 EXT. #106
rcraine@cascadealarm.com
F WI 11. l#dbUYUO Midi ill, LLL • 113: CVO., 000OU
rage. Ira uate: OR /CVUO 0.91.UO rm
�
Cascade Alarm, LLC
PO Box 7459, Kent, WA 98042
(206)- 767 -5800 or (800)333 -9860
Fax 253 - 630 -4851
Email: support @cascadealarm.com
If you have received this hr In error, Please destroy this and ceI1206 -767 -5800, duet 2. Thank you -
******************************************* ****** * ** * * * * * * ** * * * * * * * * * * * * * * * * * * **
FAX TRANSMISSION
To: 2065758680 with
From:
Subject: Domestic Reduced Pressure Backflow and Hot box
If you have any questions please feel free to call me. My cell phone is (206)391 -8646 if I'm out of the office.
We look forward to working with you.
**Security, Fire Sprinkler & Fire Alarm Systems, 24/7 Service, Local UL Listed Central Station Monitoring, Certified Inspections & Extinguishers**
City of Tukwila
6300 Southcenter BL, Suite 100 / Tukwila, WA 98188 / (206) 431 -3670
Parcel No.: 3523049092 Permit Number: 006 -325
Address: 1205 ANDOVER PK W TUKW Status: PENDING
Suite No: Applied Date: 08/21/2006
Applicant: QUILTING & SEWING OUTLET Issue Date:
Receipt No.: R06 -01403 Payment Amount: 60,000.00
Initials: BLH Payment Date: 09/08/2006 10:07 AM
User ID: ADMIN Balance: 5664.76
Payee: WACO ENTERPRISES
TRANSACTION LIST:
Type Method Description
Amount
ACCOUNT ITEM LIST:
Description
Current Pmts
BUILDING BOND /DEPOSIT
RECEIPT
Account Code
Payment Check 3380 60,000.00
000/386.908 60,000.00
Total: 60,000.00
doc: Receipt Printed: 09-08 -2006
\®
david
kehle
September 14, 2006
City of Tukwila
6200 Southcenter Blvd.
Tukwila, Washington 98188
Attn: Mr. Brandon Miles
Re: 1205 Andover Park West
D06 -325
Dear Brandon,
The following is in response to your correction letter of 9/12/06 which references both D06 -325
and D06 -335. D06 -325 is the Quilting & Sewing 11, D06 -335 is Unit A -1, North. I will address
the comments, and they are specifically for D06 -335.
1. I am not sure which drawing references an existing retail use. SD-1 references Unit A -2
as new retail/warehouse in the site plan; under change of use we referenced A -2 as a
change of use with bulk retail at 2.5/1000. The Quilting & Sewing outlet was to be getting
their business license separately and provide documentation to prove they will qualify as
bulk retail.
In an effort to expedite the construction, please remove the name Quilting & Sewing outlet
and we will go for a speculative bulk retail for the tenant.
Since Unit A -1 (006 -335) is a separate permit, we have updated that permit set to reflect
this permit as if it was already issued (thus existing retail, etc.).
2. There are actually 55 parking stalls on this site, 33 currently in front of which 11 are being
re- striped to accommodate the H.C. stall (SD-1 demo) and 10 will be re- striped including
the H.C. stall (A -1). There are 20 parking stalls on the north side of the existing building
which is off a private road. In the building and site statistics the first set of parking
calculations is for the existing uses requiring 40 cars which include s the 2"" floor office.
The second calculation is for A -2 changing to bulk retail and A -1 and Unit B with no
change and the 2"" floor offices being abandoned, the parking required is only 36 and we
have 54 cars.
12720 GATEWAY DRIVE, SUITE 116
SEATTLE, WA 98168
CITY n P
SEP 14 2006
PERMIT CENTER
325
(206) 433-8997
FAX (206) 246 -8369
email: dkehleec tinittt N
LT J R rj # f1t� ' I IUU
Mr. Brandon Miles
City of Tukwila
Re: 1205 Andover Park West
006 -325
September 14, 2006
Page 2
* ■
3. D06 -325, Unit A -2 is a separate permit from A -1 and should be viewed as such. 006 -335
is for Unit A -1 and assumes that 006 -325 is permitted and is existing. Thus, 006 -335 has
the parking calculated with both A -2 and A -1 as bulk retail and warehousing.
Regarding the second floor, since the second floor is being abandoned in 006 -325 it is not
shown in 006 -335, as it is assumed to be abandoned under 006 -325.
As for a written agreement regarding the abandonment of the second floor, we need some
acceptable language for the City to accept prior to recording. It is clearly being shown that the
second floor is being abandoned as noted in 006 -325 and the parking calculations for both
permits.
Brandon, it appears that you are getting confused with both permits. If you look at the first
application D06 -325 and assume it is complete, then the second permit, D06 -335, makes
perfect sense with A -2 being existing.
A couple of issues would remain but could be postponed until occupancy:
1. Whatever language and recording of the second floor abandonment (building didn't say
anything and might be more in their jurisdiction).
2. Quilting & Sewing outlet as bulk retail. They need to convince the City that they qualify
as a bulk retailer. I suggest taking their name off the permit and change to spec bulk
retail and let Quilting & Sewing do the convincing prior to their business license
Please proceed with Items 1 & 2 so the D06 -325 permit can be issued.
Sincerely
a U irk iltdiLd
David Kehle
DK/mt
0606/citylet9 -14-06
September 12, 2006
David Kehle
David Kehle, Architect
12720 Gateway Dr, Ste 116
Seattle, WA 98168
RE: CORRECTION LETTER #1
Development Permit Application Number D06 -325
Quilting & Sewing Outlet —1205 Andover Pk W
Dear Mr. Kehle:
This letter is to inform you of corrections that must be addressed before your development permit(s) can
be approved. All correction requests from each department must be addressed at the same time and
reflected on your drawings. I have enclosed comments from the Planning Department. At this time the
Building, Fire, and Public Works Departments have no comments.
Planning Department: Brandon Miles, at 206 431 - 3684, if you have questions regarding the
attached memo.
Please address the attached comments in an itemized format with applicable revised plans,
specifications, and/or other documentation.. The City requires that four (4) complete sets of revised
plans, specifications and/or other documentation be resubmitted with the appropriate revision .
block.
In order to better expedite your resubmittal, a `Revision Submittal Sheet' must accompany every
resubmittal. I have enclosed one for your convenience. Corrections/revisions must be made in person
and will not be accepted through the mail or by a messenger service.
If you have any questions, please contact me at (206) 433 -7165.
Sincerel
J fifer
Pe t 'tT
encl
File No. D06 -325
sh:9
clinician
City of Tukwila
P:VennifeTCorrection Letten'2005 \D06 -325 Correction Ltr #I.DOC
jeni
Steven M. Mullet, Mayor
Department of Community Development Steve Lancaster, Director
6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone: 206- 431 -3670 • Fax: 206-431-3665
DATE:
CONTACT:
RE:
ADDRESS:
ZONING:
September 12, 2006
David Kehle
D06 -325, D06 -335
1205 APW
LDR
PLANNING DIVISION COMMENTS
The Planning Division of DCD has reviewed the above permit application. The application
cannot be approved as submitted
1. The plans show that unit A -2 is "existing retail ". Yet the parking calculations are using
the "bulk retail" calculation. Please note that a sewing supply story is general retail and
must meet the parking requirements of 4 units per 1,000 square feet. Also, update the
parking on this plan to reflect the "bulk retail" in unit A -1.
2. There are 41 parking stalls provided on the site map yet the parking calculations note
that there are 54 stalls. Where are these additional stalls? Indicate where new stalls
will be provided.
3. The site maps for permits D06 -325 and D06 -335 conflict with each other. There are 11
parking stalls shown on sheet D06 -325 which are called to be removed, however these
stalls are shown in the plans for D06 -335 as remaining.
Sheet D06 -325 notes, "Mezz office of 5,692 square feet to be abandoned ". Yet this
note is not shown on D06 -335. If the mezzanine is to be abandoned clearly show the
mezzanine area on the plans. Additionally, a written agreement must be submitted to
the City and recorded with the King County recorder's office. If the mezzanine is not to
be abandoned include the square footage into the parking calculations.
�PERMiT COORD COPY .
PLAN REVIEW /ROUTING SLIP
ACTIVITY NUMBER: D06 -325 DATE: 10 -26 -06
PROJECT NAME: QUILTING & SEWING
SITE ADDRESS: 1205 ANDOVER PK W, A -
Original Plan Submittal
Response to Correction Letter #
Response to Incomplete Letter #
X Revision # 1 After Permit Issued
DEPARTMENTS:
Division
Q�
uilding Div
u lldision
Public Works ❑
Fire Prevention
Structural
DETERMINATI9N OF COMPLETENESS: (Tues., Thurs.)
Complete
Comments:
Incomplete
TUES/THURS ROUTING:
Please Route ❑ Structural Review Required
REVIEWER'S INITIALS:
APPROVALS Oy'CORRECTIONS:
Documentshouting slip.doc
2-28-02
DATE:
DATE:
1910 AP U 19t
Planning Division
Permit Coordinator ❑
DUE DATE: 10 -31 -06
Not Applicable ❑
Permit Center Use Only
INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED:
Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials:
No further Review Required
n
DUE DATE: 11-28-06
Approved Approved with Conditions ❑ Not Approved (attach comments) ❑
Notation:
REVIEWER'S INITIALS:
Permit Center Use Only
CORRECTION LETTER MAILED:
Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials:
ACTIVITY NUMBER: D06 -325 DATE: 09 -14 -06
PROJECT NAME: SPEC BULK RETAIL
SITE ADDRESS: 1205 ANDOVER PK W
Original Plan Submittal Response to Incomplete Letter #
X Response to Correction Letter # 1
Revision # After Permit Issued
DEPARTMENTS:
Building Division
Public Works
Complete
Comments:
"EMIT COORD COPY
PLAN REVIEW /ROUTING SLIP
Fire Prevention
Structural
DETERMINATION OF COMPLETENESS: (Tues., Thurs.)
Incomplete ❑
Permit Center Use Only
INCOMPLETE LETTER MAILED:
LETTER OF COMPLETENESS MAILED:
Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials:
TUES/THURS ROU ING:
Please Route Structural Review Required
REVIEWER'S INITIALS:
APPROVALS OR CORRECTIONS:
Approved ❑ Approved with Conditions
Notation:
REVIEWER'S INITIALS:
Documents/routing slip.8oc
2 -28-02
/WO 1 1-
Planning Division
Permit Coordinator ❑
DUE DATE: 09-19-06
Not Applicable ❑
❑ No further Review Required
DATE:
DUE DATE: 10-17-06
Not Approved (attach comments) ❑
DATE:
E
Permit Center Use Only
CORRECTION LETTER MAILED:
Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials:
ACTIVITY NUMBER: D06 -325 DATE: 08 -21 -06
PROJECT NAME: QUILTING & SEWING OUTLET
SITE ADDRESS: 1205 ANDOVER PK W
X Original Plan Submittal Response to Incomplete Letter #
Response to Correction Letter #
Revision # After Permit Issued
DEPARTMENTS: f-u,*
Bui ing ivision
Public Wor s wil Structural
c 5 r
DETERMINATI OF COMPLETENESS: (Tues., Thurs.)
Complete
Comments:
Permit Center Use Only
INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED:
Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials:
TUES/THURS ROU NG:
Please Route Structural Review Required
REVIEWER'S INITIALS:
APPROVALS OR CORRECTIONS:
Approved
Notation:
Documents/routing slip.doc
2 -28-02
RMIT COORD COPY
PLAN REVIEW /ROUTING SLIP
Incomplete ❑
Approved with Conditions
SO AVG 0
Fire Prevention
Planning Division
❑ Permit Coordinator
Permit Center Use Only
CORRECTION LETTER MAILED: Oil (l
Departments issued corrections: Bldg ❑ Fire ❑ PIng' PW ❑ Staff Initials:
DUE DATE: 08-22-06
Not Applicable
No further Review Required
DATE:
DUE DATE: 09-19-06
Not Approved (attach comments)
REVIEWER'S INITIALS: DATE:
C
Revision
No.
Date
Received
Staff 1 Date
Initials I Issued
( Staff
I Initials
10 n 1 .
Can
.W 1
Summary of Revision10,74'010P
d o v C f,1
1 s
i MMU +v f o r
Received By:
V
Received By: 4(;Mo %JPdAL
Revision
No.
I Date
Received
I Staff
Initials
I Date Staff
Issued i Initials
I Staff
Initials
Summary of Revision:
Summary of Revision:
Received By:
Revision { Date
No. f Received
Staff
Initials
I Date
Issued
Staff
Initials
I Staff
Initials
Summary of Revision:
Summary of Revision:
Received By:
Revision
No. ' '
Date
Received
I Staff
Initials
I Date
Issued
I Staff
Initials
1 I
Summary of Revision:
Received By:
PROJECT NAME: W t Mfr cells VR FrPERM " NO:. =a7
Site Address: 12c ArP , p•-2 - -- Origthth Issue Date: 3 .�
REVISION LOG
Revision I
No.
1
Summary of Revision:
Date
Received
Staff I
Initials
Received By:
Date
Issued
(please print)
(please print,
(please print)
(please print)
please pn
Staff
Initials
Date: Io 12310
Sheet Number(s): -A 4
City of Tukwila
Department of Community Development
6300 Southcenter Boulevard, Suite # 100
Tukwila, Washington 98188
Phone: 206 -431 -3670
Fax: 206 -431 -3665
Web site: http: / /www.ci.tukwila.wa.us
Revision submittals must be submitted in person at the Permit Center. Revisions will not be accepted through
the mail, fax, etc.
"Cloud" or highlight all areas of revision including date of revision
Received at the City of Tukwila Permit Center by . li j I Ca
Entered in Permits Plus on 10 t*
pltcatmns\fonns- application on line revaston submittal
Created: 8-13-2004
Revised:
Plan Check/Permit Number: box?' "kW- Ozs
Steven M. Mullet, Mayor
Steve Lancaster, Director
❑ Response to Incomplete Letter #
❑ Response to Correction Letter # _ CITY p
Revision # 4 after Permit is Issued OCT 2 6 2006
❑ Revision requested by a City Building Inspector or Plans Examiner
PERMIT CENTER
Project Name: &IIVVILI4 4 4 70101Pei
Project Address: 1Zt4J tatJaWQ, nt. V • a •2
Contact Person: PAW Nike Phone Number: 'l66 - -*3 -rim+
Summary of Revision:
Gov 13g Mite w4O 6E1 , UtLL5 - t b'
SEP 12 '06 03 :18PM TUKWI A DCD/PW
Revision submittals mart be submitted to person at tie Permit Center. Revisions will not be accepted through
the mall,)kx eta
Date: I Cr4 Plan Check/Permit Number: D06-325
❑ Response to Incomplete Letter
® Response to Correction Letter # 1
❑ Revision # after Permit is Issued
0 Revision requested by a City Building Inspector or Plans Examiner
Protect Name:
City of Tukwila
Deparbnent of Comrnunity Development
6300 Southeenter Boulavard, Suite #100
Tukwila, Washington 98188
Pilate; 206-431-3670
Fax: 206431 -3665
Web site: hnp: //ww:v,at,tukwtla.watts
Project Addresst I)J 1205Andover Pk W 1
Contact Person: AVM eat Phone Number: 'idle - 493•&14+
Snmmartaf Revision:
ma
to (VMS ?'10 M1E'r ffae kt
Sheet Number(s): nOlg'IaPiO
"Cloud" or highlight all areas of revision Including date of rfvtsion
��Reeeceived at the City of l'ukwita Permit Center b
lyJ Entered in Permits Plus on O\ ( I'�1 k,
appl,etuonMemu4ppuaseont alt I1nawVaton submittal
Crated: 543.2004
RSud:
P.4
Steven M. Mullet, Mayor
Steve Lancaster, Director
Mend
CflV OP T1.1KWV7LA
SEP 1 4 2005
PERMIT CENTER
n t.' e r Otis 'Co . l iaU[. �BF&t„
Kind of Fixture
Fixture Units
No. or Fixtures
total
Fixture Unite
Public
Private
Public
Private
Bathtub and Shower
4
4
Shower, per head
2
2
Dishwasher
2
2
Drinking fountain (each head)
1
.5
Hose bibb (interior)
2.5
2.5
Cloheswasher or laundry tub
4
2
Sink, bar or lavatory
2
1
1
Sink, Clinic flushing
8
8
Sink, kitchen
3
2
1
f (,
Sink, other (service)
3
1.5
Sink, wash fountain, circle spray
4
3
Urinal, flush valve, 1 GPF
5
2
Urinal, flush valve, >1 GPF
6
2
Water closet, tank or valve, 1.6 GPF
6
3
)
t
Water closet, tank or valve, >1.6 GPF
8
4
Non - Residential
Sewer Use Certification
(To be completed for all new sewer connections, reconnections or change of use of existing connections.
This form does not apply to repairs or replacements of existing sewer connections within five years of disconnect)
Pursuant to King County Code 28.84, all sewer customers who establish a new sewer customers. The charge is collected semi-annually. All future
new service which uses metropolitan sewage facilities shall be subject to a billings can be prepaid at a discounted amount.
capacity charge. The amount of the charge is established annually by the
King County Council at a rate per month per residential customer or
residential customer equivalent for a period of fifteen years. The purpose of
the charge is to recover costs of providing sewage treatment capacity for
(Please print or type) `", _ �� Property Tax ID # J/ -K, j•1!i • tee, tee, Owner's Name l� Z •(d
(Last, Fi Muddle meal) Party to be Billed (if different from owner)
Subdivision Name Lot # Party's Mailing Address:
Subdiv. # Block #
Building Name (If applicable) 1 G,
Property Street Address Zo % 14 cvat Ric
City or Sewer District
j ��' 1 ``` d1W t
1,t ,y 4 Date of Connection �(�114•f4 •
City, State, ZIP �)1 ' WA • 1:41) Side Sewer Permit # ' Abaft s' ' •
/1s
Owner's Phone Number ( •par+ ) or Property Contact Phone # ( )
Owner's Mailing Address (if different from above) Demolition of pre - existing building? 0 Yes Otto
Type of building demolished
Sewer disconnect date
A. Fixture Units
Fixture Units x Number of Fixtures = Total Fixture Units
1058 (Rev. 1/03)
Total Fixture Units
Residential Customer Equivalent (RCE)
20 fixture units equal 1.0 RCE
Total No. of Fixture Units _
20
be3o 1
RCE
White — King County
(P
King County
Department of
Natural Resources and Parks
Questions regarding the capacity charge or this form should be referred to
King County's Wastewater Treatment Division at (206) 684.1740.
B. Other Wastewater Flow
(in addition to Fixture Units identified in Section A)
Type of Facility /Process
Estimated Wastewater Discharge:
4 (p, Gallons/days
Residential Customer Equivalents (RCE):
187 gallons per day equals 1.0 RCE
A
B
Total Discharge (gal/day) _
187
C. Total Residential Customer Equivalents:
(add A & B)
r
RCE (//�,�� 52-9
I certify that the information given i - correct. I understand
that the capacity charge levied will be based on this
information and any deviation will require resubmission of
corrected data for determl;..'on of a revised capacity
charge.
0.3o
Signature of Owner/
Representative
141A
Print Name of Ownet "ice'►""
Representative �
Date t1
Yellow — Local Sewer Agency Pink — Sewer Customer
RCE
RECEIVED
CRY OF TUKWILA
AUG 2 1 2006
PERMIT CENTER
License Information
License
KELLYTI 1 48CR
Licensee Name
KELLY THOMAS INC
Licensee Type
CONSTRUCTION CONTRACTOR
UBI
600606877
Ind. Ins. Account Id
49848700
Business Type
CORPORATION
Address 1
26318 ENTWHISTLE RD E
Address 2
City
BUCKLEY
County
PIERCE
State
WA
Zip
98321
Phone
2537353928
Status
ACTIVE
Specialty 1
GENERAL
Specialty 2
UNUSED
Effective Date
2/19/1986
Expiration Date
1/29/2008
Suspend Date
Separation Date
Parent Company
Previous License
Next License
Associated License
Bond Information
Bond
Bond
Company
Name
Bond Account
Number
Effective
Date
Expiration
Date
Cancel
Date
Impaired
Date
Bond
Amount
Received
Date
#3
CBIC
626389
01/29/2002
Until
Cancelled
$12,000.00
01/18/2002
#2
CBIC
626389
01/29/1990
01/29/2002
56,000.00
Business Owner information
Name
Role
Effective Date
Expiration Date
KELLY, PATRICK K
01/01/1980
11/10/2005
THOMAS, FREDRICK A JR
01/01/1980
11/10/2005
Look Up a Contractor, Electrician or Plumber License Detail Page 1 of 2
Washington State Department of Labor and Industries
General/Specialty Contractor
A business registered as a construction contractor with L&I to perform
construction work within the scope of its specialty. A General or Specialty
construction Contractor must maintain a surety bond or assignment of
account and carry general liability insurance.
https: // fortress. wa. gov /Ini/bbip /printer.aspx ?License= KELLYTI148CR 09/29/2006
x
x
x
x
x
x
x
x