HomeMy WebLinkAboutPermit M95-0079 - TOYS R US1-6\h R us tral5i00T19: City of Tukwila 1.. (206) 431 -3670 Community Development / Public Works • 6300 Southcenter Boulevard, Suite 100 • Tukwila, Washington 98188 MECHANICAL PERMIT Permit No: M95 -0079 Type: B -MECH Category: NRES Address: 16700 SOUTHCENTER PY Location: Parcel #: 262304 -9128 Contractor License No: ADVANFS071D6 TENANT OWNER CONTACT CONTRACTOR Status: ISSUED Issued: 05/31/1995 Expires: 11/27/1995 Suite: TOYS R US REAL PROPERTY WEST INC 101 CALIFORNIA ST, SUITE 2525, SAN FRANCISCO CA 94111 MARK KELSCH Phone: 206 770 -2440 516 VALLEY AVENUE NE, PUYALLUP, WA 98372 ADVANCED FILTER SERVICE INC. Phone: 206 770 -2440 516 VALLEY AVE NE, PUYALLUP, WA 98372. • **********************,******************.*** *, ** ** * * * * * * * * * ** * * * ** * * * * * * * ** Permit Descrip.ti'on: REPLACE FOUR HVAC.UNITS UMC Edition: 1991 Valuation Total Permit Fee: 8,000.00 63.75 * *, * * * * * *.. * * * * * * * * * * * *: * * * * ** *******.**** * * * * * * * * * * * * * * * * * *** *. * * * * * * * ** Perm 'yt Center *uth• tied Signature: Date �' I hereby certify that I have read and examined this permit and know the same to be true and correct. A11 provisions of law and ordinances, governing this work will be complied with, whether specified herein or not. The granting of :this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction the performance of work. I am authorized to sign for and obtain this b i1 ng,perm Signature: - � ^�? Date: S r Print N ame:__ L,f Title: SeRViL - MA-cl,*✓;C, This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of .,180 days from the last inspection. CITY OF TUKVV Department of Community Development — Permit Center 6300 Southcenter Boulevard - #100, Tukwila, WA 98188 (206) 431 -3670 Mechanical Permit Application Tracking PLAN CHECK NUMBER mq5 -Ccnq PROJECT NAME 3 1R' Os SITE ADDRESS • •_• A. sk. I A' .1 SUITE NO. S000-- INSTRUCTIONS TO STAFF • Contacts with applicants or requests for information should be summarized in writing by staff so that the status of the project may be ascertained at any time. • Plan corrections shall be completed and approved prior to sending to the next department. • Any conditions or requirements for the permit shall be noted in the Sierra system or summarized concisely in the form of a formal letter or memo, which will be attached to the permit. • Please fill out your section of the tracking chart completely. Where information requested is not applicable, so note by using "N /A ", date and initial. DEPARTMENTAL REVIEW "X" in box indicates which departments need to review . the project. DEPARTME i,TE. ;IN DATE. ' •<'APPROVE UIREMEN MEN 9(BUILDING - initial review .'FIRE 516 ROUT D 5,30/9)' CONSULTANT: Date Sent - Date Approved - FIRE PROTECTION: • Sprinklers Detectors • N/A INIT: 44" n FIRE DEPT. LETTER DATED: Si 3 on9, INSPECTOR: S-1/ O PLANNING ZONING: BAR/LAND USE CONDITIONS? U Yes (J No INIT: SCREENING REQUIRED? ❑ Yes 0 No REFERENCE FILE NOS.: O OTHER INIT: BUILDING - final review 'BUILDING OFFICIAL 5, INIT: _P-1—N... i C ;L r %11/1'J INIT: / ,., REVIEW COMPLETED UMC EDITION (year): ti 1 ( AMOUNT CWING: CP CONTACTED tinA n f� l•` DATE NOTIFIED `'Ir i /� "l� BY: (init.) 2nd NOTIFICATION BY: (init.) 3RD NOTIFICATION BY: (init.) 01/07/93 MECHAN (._)AL PERMIT APPLICATION 1 ,. CITY OF TUKWILA Department of Community Development - Building Division 6300 Southcenter Boulevard, Tukwila WA 98188 (206) 431 -3670 PLAN CHECK l- NUMBER I 7 --7 cl APPLICATION MUST BE FILLED OUT COMPLETELY FEES (for staff use only) DESCRIPTION AMOUNT RCPT # :.: ' %DATE BASIC PERMIT FEE 15.00 TYPE OF WORK: Q New /Addition Q Modifications Q Repair g Other: 4 t r raA DESCRIBE WORK TO BE DONE: PAP t c1 E ft v 0 c uL IA 45 1 4 6 c L. UNIT(S) FEE r 7, -7, L J4• ZI 32`-.�S -O3 PLAN CHECK FEE BUILDING USE (office, warehouse, etc.) NATU E OF BUSINESS: *e let c . e ,__1-- - `c. --5. ,_ _ 1- ca N u r4 C IA h ‘ OTHER: WILL THEE BE A CHANGE IN USE? Q No Q Yes IF YES, EXPLAIN: WILL THERE BE STORAGE OR USE OF FLAMMABLE, COMBUSTIBLE OR HAZARDOUS MATERIALS IN THE BUILDING? 'No 0 Yes IF YES, EXPLAIN: TOTAL - SITE ADDRESS SUITE # F00.- PKu, y ' VALUE OF CONSTRUCTION - $ c? 00 o I OL .5 le' CC S - a_j6v tY A £ Q4 ,r/ 7 off, «il,,ee•41e2. PROJECT NAME/TENANT ,)2 t, ASSESSOR ACCOUNT# 537ga0- L_C.Q C 30 q - t g 0315 , di rJ V S / e -f-kZU r'1c.,- TYPE OF WORK: Q New /Addition Q Modifications Q Repair g Other: 4 t r raA DESCRIBE WORK TO BE DONE: PAP t c1 E ft v 0 c uL IA 45 1 4 6 c L. TYPE >RATING>51ZE :..' ;::. ;: :,::. ::.:NUMBEB:O.:; ITS.: ..m:�:;. r 7, -7, L J4• ZI 32`-.�S -O3 WA. ST. CONTRACTOR'S LICENSE # e 6 60 3 71.170 BUILDING USE (office, warehouse, etc.) NATU E OF BUSINESS: *e let c . e ,__1-- - `c. --5. ,_ _ 1- ca N u r4 C IA h ‘ WILL THEE BE A CHANGE IN USE? Q No Q Yes IF YES, EXPLAIN: WILL THERE BE STORAGE OR USE OF FLAMMABLE, COMBUSTIBLE OR HAZARDOUS MATERIALS IN THE BUILDING? 'No 0 Yes IF YES, EXPLAIN: PROPERTY OWNER 7.4 S T' �S PHONE // .�-� ADDRESS /(D r%C�O Sc, "/A, N eh� -1 �/�W � 4- 1/ 604 Z7 CONTRACTOR Ap/%a «c eep -HeA / �.. P( 6 ) 72c - 44'O ADDRESS 3'/, t%a. //° 4 ' , AZ ,. ,ay- 7, -7, L J4• ZI 32`-.�S -O3 WA. ST. CONTRACTOR'S LICENSE # e 6 60 3 71.170 EXP. DATE I HEREBY.: CERTIFY THAT HAVE READ AND EXAMINED THIS: APPLICATION AND KNOW THE SAME TO BE TRUI AND :CORRECT; AND:f'AM'AUTHORIZED:TO APPLY :FOR THIS:PERMIT BUILDING OWNER SIGNATURE 1K,>z4-7K- OR PRINT NA AUTHORIZED AGENT ADDRE DATE PHONE - -- - • • - CITY2IP Fcra- step PH ON e0 770 CONTACT PERSON MAg-K e%�� APPLICATION SUBMITTAL In order to ensure that your application is accepted for plan review, please make sure to fill out the application completely and follow the plan submittal checklist on the reverse side of this form. Application and plans must be complete in order to be accepted for plan review. BUILDING OWNER /AUTHORIZED AGENT If the applicant is other than the owner, registered architect/engineer, or contractor licensed by the State of Washington, a notarized letter from the property owner authorizing the agent to submit this permit application and obtain the permit will be required as part of this submittal. VALUATION OF CONSTRUCTION The valuation is for the work covered by this permit and must be filled in by the applicant. This figure is used for budget reporting purposes only and not to calculate your fees. EXPIRATION OF PLAN REVIEW Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may extend the time for action by the applicant for a period not exceeding 180 days upon written request by the applicant as defined in Section 304(d) of the Uniform Mechanical Code (current edition). No application shall be extended more than once. If you have any questions about our process or plan submittal requirements, RECEIVED please contact the Department of Community Development at 431 -3670. CITY OF TUKWILA DATE APPP„LIFATIR\CCEPTED �— / 7-95 DATE APPLICATION EXPIRES // -/7 -9S PERMIT CENTER 03/14/94 SUBMITTAL CHECKL.IT MECHANICAL Completed mechanical permit application (one for each structure or tenant) Two (2) sets of mechanical plans, which include: • Floor plan • System layout • Elevations (for roof mounted equipment) t._• Heat Loss Calculations Structural calculations stamped by a Washington State licensed engineer may be required if structural work is to be done (2 sets) Note: Hood and duct systems require a building permit for the duct shaft. Water heaters and vents are included in the UMC — please include any water heaters or vents being installed or replaced. r- DETACH TO DISPLAY CERTIFICATE DEPARTMENT OF LABOR AND INDUSTRIES THIS CERTIFIES THAT THE PERSON NAMED HEREON IS REGISTERED AS PROVIDED BY LAW AS A coN ,: CONT= '. gENERAL - REGISTRATlON NUMBER • ;EXPIRATION GATE ri.AiJY NFS 71176'. EFFECTIVE ,.DATE; 12 "O7/95 Q3i'26/93 ADVANCED . -F 3 LTER SER41 OE= 516 VALLEY AVE N E. PUYALLUP IM 98372 • • v W\\\\NN KYWNII'N 4!! K\Nl AhW4NNA Nyvy.MMWNFNNV.\ \N\1M1N,%,,,Nv 44 \hN\\ STATE OF WASHINGTON F625.052.000 (3.92) t DETACH TO DISPLAY ' ERTIFICATE .1 w3: a». u.. w.:.' S'. 4�: G./.:.: 1LJlcv�roy,. u..+ vYnu• • ��w� .ww..wr...........+.�.•ru.....r •...rw...r•www.nwi.+.rl' LY:».':�'. *f+•.:.k".(.'.:...«:' INSPECTION RECORD Retain a copy with permit CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (21)61_ 3670 y&s. Approved per applicable codes. COMMENTS: ❑ Corrections required prior to approval. Inspector: Dale: ❑ $30.00 REINSPECTION F FREQUIRED. Prior to reinspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. CaN to schedule reinspection. ,; r .:; Address: . / , . / ....rdl Date Calved: two.. `I am. Requester: Phone No.: y&s. Approved per applicable codes. COMMENTS: ❑ Corrections required prior to approval. Inspector: Dale: ❑ $30.00 REINSPECTION F FREQUIRED. Prior to reinspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. CaN to schedule reinspection. ,; r .:; INSPECTION RECORD Retain a copy with permit CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 IA 15 PEQRA y (206) 431 -3670 •r.: o' %S s kik. YPeo ns.:..: FINAL Addr1sa: iDo cuTcleet,ime. p ') Date Called: 17 - 20 Special Instructions: 9 () A..A . .. -LvA. =. - -- , Date Wanted :1 2. - 21- q '5 am. .m. Requester. CON N 1 G RhoneNo.: ---1 e _ 2.14Lio 0 Approved per applicable codes. Corrections required prior to approval. COMMENTS: Inspector: / Date: r r . . ,i 4.4.4411 ►: EINSPEC • FEE REQUIRED. Prior to reinspection, fee must be paid at r Southcenter Blvd., Suite 100. CaII to schedule reinspection. ° INSPECTION RECORD Retain a copy with permit. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 7e PERMT NO. (206) 431-3670 • 4, . . TT < ,..• 0_ S ype o rIS • : & • ... p4,4,__ Address: / , 6:11.A1,, Caked: 7-2?- - 9-5— 4, •,620 Special Instructions: ti) e n—: /77-7 4O le Wanted: 2--/-4(.5- ("Et` P.m. Requester: Phone No.: — 0 Approved per applicable codes. CorrectionkreqUiritprior to approval. COMMENTS: ... p4,4,__ la e , • An_.ttfe, 1-7/"-• . cr; -74(,e ti) e n—: /77-7 4O e_..7frx A • 64-7_,_ 6,g L../ ., r•re e--( /4 /7_,L,),,g., \. ,,k`v-' c■clz-qb f.,C-:,,,C`4)-k A`rs-CS r- Date: .00 REINSPECTIONFEE R silig6iPtIr to reinspSction, tee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. , • • ' • INSPECTION RECORD Retain a copy with permit CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 •r.: Ic�� �;.t e. (I 5 S meo ; ;Ina `. " Address: ►(� O s.ce,�icr" el Date Cabled: r7 /a7 C15 Special Instruct . Date Wanted: curl,... ro' am. pm. Requester. Lo on n i Phone No.: -7-70- o"? t--i LI O O Approved per applicable codes. AEorrections required prior to approval. COMMENTS: /Gri/a S (2 - e.A /)2r f j L D $30.00 REINSPECTION FEE REQUIRED. Prior to reinspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: 4" ' • • :v7,)=S-x44.44,40.--r424.1.-'eu:.1,106,17..rsot..;,14;\.A6:77-I"-.77.77,.,....,,,i.„ City of Tukwila Fire Department John W. Rants, Mayor TUKWILA FIRE. DEPARTMENT Permit No. Ages- 602 FINAL APPROVAL FORM Project Name 7;-611/S le A:5 Address /40 ,19141/40,ql,t, --"Y Retain current inspection schedule Needs shift inspection Thomas P. Keefe, Fire Chief Suite # -1( Approved without correction notice Approved with correction notice issued Sprinklers: Fire Alarm: Hood & Duct: Halon: Monitor: Pre-Fire: Permits: c74 Authorized Signature FINALAPP.FRM Date T.F.D. Form F.P. 85 Headquarters Station: 444 Andover Park East • Tukwila, Washington 98188 • Phone: (206) 575-4404 • Fax (206) 575-4479 ''* AA• k***** A* k k *A * **A *•A *Ah *A **A,tA * *. *k * * *.: *Ak4- Ak•A*4 *A *P * * *k *A•'*A' *A* ,.CITY OF TIJ! WILA. WA TRANSMIT *A**kA* *•N *k* * *** *** A* k• A•*, t• F•*** A.*:* 4****A k* A *kk•*• *4 *A *3A **pillhyk*OJ•f53 'TRANSMIT Number: 96003617 'Amount: 42.00 02/13/56 13.09 Payment Method: CHECI! Notation: NATHAN ROBERTS Snit: Sus Permit No M93-0079 Type :.I3• -MECH MECHANICAL PERMIT., Parcel Not 2629.04 -912a Site Add ess x 1.6700 SOUTHCENTER PY Total frees: Thit Payment 42..OQ Total ALL Pm s:: U ail anCe.' 105„75 1.05.75 .00 �� ttA• ik* d• A• kA, i'• kA*• k*,**+ 1• A**•. t*#•• kAkot�k. A•k *+kkk *k *�F * *A�k *rotk•t * * >t *at •1• *•A *�t•►.• *k *stir* GENERA TOTAL CHECK CHANGE 2655A000 42.00 42.00 42.00. 0.00 15 :50 o. r'k** A• AA*****• h*• h* A*• 4***•* kA lire•h•h•k•kk*A••h**•4***A***•1 *•h•.4** * **A****k 44* ;TTY OF TUKWILA,. WA • TRANSMIT r, 4A* k: kA4**4• h• k• k• hAA lr *'A* ** *.A**!.** * ****•h•4 **•A•k4 *A*** **.**4.44 *A•A * *A *4* GENERA 63.75 TOTAL 63.75 CHECK 63.75 ,. 6.75 'p5 /i. /:�� ^1�► . CHANGE 0.00 T RANOMIT Number . 9400..369 Amount: 6/I 3137A000 16101, Payment Method:: CHI=CK( Notation: ADVANCEI' .FILTER £ni p AQ Permit No: M95 -0079 Type :. H -MECH MECHANICAL. PERMIT • Parcel No :'62304 --912 Site Address: 16700. tOUTHCE NTER PY This Payment Total Keelsa 63 ;75. - 6305 Total. ALL:11mtsa• 63.15 • Balances X00 r * * ** *0 **4******• k• ks4• 4* 4* •iti %.A *4* * * **• * * * **• *.t4*4 **** *tic *•4*•h' *4 *'h **4 *444 Accaunt.Code Description Amount 000/345.1130 PLAN. CHECK NONRE±a 000/322.100 MECHANICAL 7 NONRE,"a' 5140 Address: 16700 SOUTHCENTER PY Suite: Tenant: TOYS R US Type:.B -MECH Parcel #: 262304 -9128 *•k k* *•k*•k * ** * * ** * * * * * * *•k * * ** * * * ** k* k k * * ** k ** *•k * **•k** k•k k *•k•k k * * *•k•k* * **•k k * *•k * ** Permit Conditions: CITY OF TUKWILA Permit No M95 -0079 Status: ISSUED Applied: 05/17/1995 Issued: 05/31/1995 1 No changes will be • made. to; h; n;?�%1 :i u °e.s4:.� approved by the Architect or Engineer . iq the"'- Tu wi `1`a -8°u 1d.�1ng ,Division. 2. All. permits, insp. .$n recorids • and approve°d': plans shall be available at th. ;ob site ` .p` i�vr` to ^the start of ar. ; • ' ' ; on- struction.•, ewe docbm tsfr at 0,,,t, re main;`t in �>d arl ai 1- ab l e anti 1 'f4 i l - .i nVs est ;on' approval i =s gr ainl,Ete'd . . Al 1 Cons tar t'ion, to b4e done oi:n 'cbr i`b`hmar, c.e w�1't,jiy appro .'plans andd equui r °+one its cif the U ir, arm, Bu i1 tipg G d "A N19' Edition ; i arnended, Uiiiform"�;M ical Code 4‘1991t, Editio and Wa -i tan 'S'tate'Ener Code ( 94 Edition)' " e . Val id,it'� of eririi+t The.�``' r nce o�'a permit ar4ppr�cu;a'1 plan's pe`fii.cat,�ions,nd co�rput,a't�ians • shall not be zc«f,, -t. strule,,top..b,,,,�a p'armitY�t'0, or peril- 'ap,pr,ova1 of, any v0iala of arty of the provisions• -••at ,.tA bui •;drfng code or of'an� other' ordii.narnce' of th,ef1u.risdilction} ,Nc,..permit presumiarig'' o g i ve'`�';authority to ..v o l ate ''ar' `cana l th r .V1 �. e p o. i s i arts of tit(si's °��, codeAsha11 rbe ;.va�l:'id ,\ r,( l'-,_''' ; A .a. ' • w• 5. MANUFACTURER .:,IN�:�TALLATI0N, ; I:,N TRUC':I�0N•S'._REOUIRED ON i�'ITE�"v 4 FOOT THE BUILDING r'I•N.�,PECTQR .5' RCVIEi� >' �� r 6 . Plumbing {;:,),,er ~mtts shall b,e •ob;ta.i`ned throughthe Seatt le -K; i ng Country Depa`t;tment o,f;,.:P;i „bb11.,c= Health,`"',P „1,u: ib,ing wi 11 be ;' inspe:oted "by, that agency,' inc1udl'niii all g`as-":pIping ,, (296;4�722)`;s . +,,, t .. ,,.,,� 7. Elects l ,,ca >>. per�mi'ts shall be obtained thrtou,gh the Washi;n,g�ton State {D;1v1"lon af�•,Labor and Indusitries and 'a,ll�`�eleotri`ca.f1, work wyil 1 pe inspected by that agency, •248_,6E 30;);, "'' 8'. Readily % cces:lblre access to roof mown ed yeq.u'i rnent �1,s required ;.. ,, PI W 1 ;, FLT,ER :7;7 516 Valley Avenue Northeast Puyallup, Washington 98372 -2503 FAX (206) 770 -2443 'hone "(206) 770.2440 • (800) 783.2539 DATE: To :I T 4i14 FAX # 1 1-306/ ATTN: FROM: RE: NUMBER OF PAGES TO FOLLOW: MESSAGE: I, 2-0 fi.,C14 P _ 0 1 RECEIVED 4 1995 CUtvliviutli FY DEVELOPMENT A/O.MIL :771,AZ. __.‘&7F7A,,d et.) itte eit't e ;Wd 71g �• .. 741)1-10'\\14111\_ Q ,x..2.5.1995 IF THIS COPY IS ILLEGIBLE OR INCOMPLETE, PLEASE CALL 770 -2440 IH THE TACOMA AREA OR (800) 783 -2539 ANYWHERE OUTSIDE OF TACOMA, FOR RETRANSMISSION. THANK YOU. • ... •• .. • .w., r •.,..; • , • • • • ••••• . • .. 9 43 ADVANCED.: F/LTE/ SE/ I//GE,_. O, 516 Vglley Avenue Northeast Puyallup, W F FAX 98372-2503 (206) 770- 2443 hone: (206) 770 -2440 • (800) 783-2639 May 24, 1995. City of Tukwila ATTN: Ken P . e 2 RE: Toys R Us #8002 Dear'Ken, Advapced Filter Service proposes to remove and away 4 w existing TRANE roof top units and replace t units, model #48TJD020. Toys R Us to furnish units, curb's, economizers and controls. No ductwork i'evisions will be necessary. The units to be removed area sketched] on the next page to follow. The new units will be placed exactly where existing units are located. The :new Carrier units are approximately 1,850 pounds and the eConnmizers are approximately 110 pounds. 1 have also enclosed specifications on the equipment to he installed. ii Should you have any questions, or require furt-tier information from us, please call at the number given above. F.,&401-7,a4f9 Respectfully Submitted, Connie'A Feldkamp MECHANICAL'COORDINATOR CON TUKWILA APPROVED tip( 251995 n! 111. IN( DIVISIO' k; 4 20 - 1. ipmwammonw•.••• JAN- 5-96 FR X 8 :58 or nrs.nrr- rerte-PirO 516 Volley Avenue Northeast Puyallup, Washington 96372-2503 FAX (2b6) 770-2443 Phone: (206) 770-2440 • (800) 783-2539 DATE: To: FAX # q3/-3 ATTN: FROM: e244i RE: RECEIVED 95-0cy NUMBER OF PAGES TO FOLLOW: / JAN 0,5 1996 COMMUNiTY DEVELOPMENT P 01 MESSAGE: owsiitthd ZiFie,,X.OVeck ,,Ztle-X(e/1‘- 4#144' a)/ae‘4, A 1.ez,tada Ac, n7f SCe JPz-t (71. /4; VAg ( < VC „ix. ti,-/e adoveetcp1Kf ?\ /Lo) : fyt- .W.A./ .r IF THIS COPY IS ILLEGIBLE OR INCOMPLETE, PLEASE CALL 770-2440 IN 110 TACOMA AREA OR (800) 783-2539 ANYWHERE OUTSIDE OF TACOMA, FOR RETRANSMISSIoN, THANK YOU. JAN - 9 E. F R I 8: 5 9 JAN-04-'96 13:42 ID: JAN 04 '96 11:55AM DEPT OPAL &I TUKWILA) ** TEL N0:841089` ` ACTIVITY INSPECTIONS P . 02 01/04/96 10:65 Activt No 95124160 1 -4 CIRCULTS Tyya: COM• Applicant: UMRIDIAN CEN IR ELECTRIC INC 1 St &cU• : FINATI Locb,tion: 16700 $OJTHCF`NTZR PRKWY TUKWIL No. Dedc /Date Act Inspector Comments (3.) (2) T &b1A : 9 0$LRCIt1S - 01 S Esc: 02 ... * Final «+ No 3ntriea ** * Mieo. ., 04/28/95; DC 07885 AC Unit /Meat pure /Furn,Ce 08/16/95 DP 09770 AC Unit /Heat Pump /Furnace 09/19/95 AC 09574 AC Unit/Heat mg/Furnace �- 1,.,Z ,'"'' ate �P I GAG j I No: Act: Insp: Date: New Next Mitre f4 N era,kda COMM: ! S 'f6 f'7 P.et u rn SAN- 4 -96 THU 13:20 i't< b- s Itiu IU:UJ CERTIFlED DIMENS'.ON PRINT 6� H1c<tt.11., 1NU f•?S NUJ, CUt( UI•b r. U? 0TJD /TJ!!01E /48T:00?o UNITS CO G / 1DfMATJQN GAS HEATINttECTRIC CONING NG UNITS T;;;;00067.13 � " gl gi. 5 i-41 „6e E TA 0r ! I111I¢ 11 I 421 11 y� a ' 111 12 n tl hH LpGD �xxiZ�i� Wi n 1 r (tSSSSwLga~d'��j�4j��� A� stn 1 i3 uM t� Ir :L i i • Y sa rso b 0 t. ' .L .� O~ 41 4 h 3 ..s 0 O Ig Az .-- -- __ . - .. _._....�.. CPI re. 0 fit': 6 - Qam o6- bZ- -�lkiW ...- HrK- ti-'4!) INu 1U:UJ Hl(irl INU t* HA P {u, ?Lid( 5 UILb M1/4 — [...or :1 a 1 i .._..__. -1- in 9 _____.wi 2 2 I oa K r_ 1 A 140 !II I i i-- ---- —T- ! ,1. 111- 11 1 I i I ..i f !1:4 ( ' T 1 g 2 F. 9 sr t 4\1 t 4 0 - ;,75 A / .._�._ • •.teOa ..0..• __,• ._■•_ .••••• .__ •••••••••■. FIL COPY City of Tukwila John W. Rants, Mayor Dec 18, 1995 Department of Community Development Steve Lancaster, Director MARK KELSCH 516 VALLEY AVENUE NE PUYALLUP, WA 98372 RE: TOYS R US Dear Permit Holder: Our records indicate that on Jan 28, 1996 one hundred and eighty days will have passed with no inspections having been called for under Tukwila Mechanical Permit Number M95 -0079. Unless you call for an inspection, or obtain a written extension from the Tukwila Building Official prior to that date, your above referenced permit will become null and void on Jan 28, 1996. If your project is complete please call for final inspection. If you are actively working on your project please contact our office. If you have any questions or need further information to obtain an extension on your permit please call the Tukwila Building Divison at 431 -3670. Sincerely, 1 M6c .79-ate5O?7 Kelcie Peterson Permit Coordinator Department of Community Development 6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • (206) 431.3670 • Fax (206) 431-3665 City or Tukwila FIRE DEPARTMENT 444 Andover Park East Tukwila, Washington 98188 -7661 (206) 575 -4404 John W. Rants, Mayor May 30, 1995 Fire Department Review Control #M95 -0079 (511) Re: Toys R Us - 16700 Southcenter Parkway Dear Sir: The attached set of building plans have been reviewed by The Fire Prevention Bureau and are acceptable with the following concerns: 1. H.V.A.C. units rated at 2,000 cfm require auto - shutdown devices. These devices shall be separately zoned in the alarm panel and local U.L. central station supervision is required. (City Ordinance #1646) Smoke detectors required by Uniform Mechanical Code Section 1009 (a), (HVAC 2000 cfm and greater), shall be installed in the main return -air duct ahead of any outside air inlet or they may be installed in each room or space served by the return -air duct. Detectors shall also be installed in the supply duct, downstream of the filters. Activation of any detector shall cause the air-moving equipment to automatically shutdown. 2. Remote indicator lights are required on all above ceiling smoke detectors. (City Ordinance #1646) Remote alarm annunciation indication is required if the control panel is not visible from the main entrance. (City Ordinance #1646) (UFC 10.501(a)) The installation of wiring and equipment shall be in accordance with NFPA 70, Article 760, Fire Protective Signaling Systems. (NFPA 72-2 -1.4) When the control panel is located inside a room, the door to the room shall have a sign with one -inch City br Tukwila FIRE DEPARTMENT 444 Andover Park East Tukwila, Washington 98188-7661 (206) 575 -4404 Page number 2 John W. Rants, Mayor letters which reads "Fire Alarm" or "Fire Alarm Control ". (City Ordinance #1646) Dedicated fire alarm system circuit breaker(s) shall be equipped with a mechanical lockout device. (NFPA 72 (1- 5.2.8.2)) Duct detectors shall be capable of being reset at the alarm panel. 3. All new fire alarm systems or modifications to existing systems shall have the written approval of The Tukwila Fire Prevention Bureau. No work shall commence until a fire department permit has been obtained. (City Ordinance #1646) (UFC 10.503) Call the Tukwila Fire Department at 575 -4407 for approval of any system shut down. Have job site address, name and the Tukwila Fire Department. Job Number available to confirm shut down approval. (City Ordinance #1646) This review limited to speculative tenant space only - special fire permits may be necessary depending on detailed description of intended use. Any overlooked hazardous condition and /or violation of the adopted Fire or Building Codes does not imply approval of such condition or violation. Yours truly, The Tukwila Fire Prevention Bureau cc: T.F.D. file A41 SII ncd �`�"^'z Y+u13t'i; x;t, .y.r i•i .. u, >ic Tr Yrr.` .r M,. ,'�.,`. >: , -, w � ".f:_ .�ir.t.!'S; :t': ,. .,'� t 'if:?�:"r: Et,..f..., X fit CITY OF TUKWILA Id: ROUT130 Keyword: UACT User: 1677 05/25/95 Activity document routing maintenance. MECHANICAL PERMIT Permit No: M95 -0079 Tenant: TOYS R US Status: PENDING Address: 16700 SOUTHCENTER PY Route: 1 Current Route Line: 2 of 5 Packet Units Description Station Status Received Assigned Complete aaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaa Packet Units Action Station Initials Status Received Assigned Completed MECH 01 01 C BLDG KEN Ap Cond. 05/17/95 05/22/95 05/25/95 Priority (0 /low..9 /high): 0 Regular hours (HH.MM): .00 Overtime Hours(HH.MM): Comments 1[CALLED LEFT MESSAGE TO HAVE RETURN CALL ON EQUIPMENT. 5/22/ ] 2[ ] 3[ ] 4[4 H.V.A.C. UNITS > 2,000 CFM REQUIRE AUTO SHUT -OFF. ] 5[ ] 6[FIRE PLEASE REVIEW AND COMMENT. BY KEN ] 1 1 7( s( 9( ] 10( ] aaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaa F1 =Help, ESC =Exit current screen. GENERAL NOTES DESIGN: BUILDING CODE - GROUND SNOW LOAD - :1 WIND -' SEISMIC - 1988 UBC 30 PSF 80 MPH ZONE 3 FOUNDATIONS; THE FOUNDATION HAS BEEN DESIGNED IN ACCORDANCE W. THE RECOMMENDATIONS MADE IN THE "SOILS AND FOUNDATION INVESTIGATION' PREPARED BY CASCADE GEOTECHNICAL 12911 N.E. 126th PLACE KIRKLAND. WASHINGTON 98034 (206) 821 -5080 2 SPREAD FOOTINGS SHALL BEAR ON SOIL CAPABLE OF SUSTAINING A NET ALLOWABLE BEARING PRESSURE OF 2.0 KSF FOR INDIVIDUAL COLUMN FOOTING AND 2.0 KSF FOR CONTINUOUS WALL FOOTINGS UNDER FULL SERVICE LIVE AND DEAD LOAD. 3. PFOOTINGS MAY BE POURED INTO AN EARTH - FORMED TRENCH IF SOIL CONDITIONS ERMIT. 4. ALL BEARING MATERIAL SHALL BE INSPECTED BY THE INDEPENDENT TESTING AGENCY PRIOR TO CONCRETE PLACEMENT. THE INDEPENDENT TESTING AGENCY SHALL BE THE SOLE JUDGE AS TO THE SUITABILITY OF THE BEARING MATER +AL FOOTING ELEVATIONS SHALL BE ADJUSTED AS REQUIRED. 5. BOTTOM OF EXTERIOR FOOTINGS SHALL BEAR A MINIMUM Of 1B BELOW FINAL GRADE FOR FROST PROTECTION. 6. FOUNDATION WALLS THAT RETAIN EARTH SHALL BE BRACED AGAINST BAC.KFIL•!NG PRESSURES UNTIL FLOOR SLABS AT TOP AND BOTTOM ARE IN PLACE. 7. WHERE FOUNDATION WALLS ARE TO HAVE EARTH PLACED ON EACH SIDE. PLACE FILL SIMULTANEOUSLY SO AS TO MAINTAIN A COMMON ELEVATION ON FYr7-I SIDE OF THE WALL. 8. FOUNDATION WORK SHALL BE SUBJECT TO QUALITY ASSURANCE TES.( AN, INSPECTIONS. SEE DIVISION 2 SPECIFICATIONS. CONCRETE: CONCRETE SHALL HAVE A 28 -DAY COMPRESSIVE STRENGTH AND DENSITY. IN ACCORDANCE WITH THE FOLLOWING: STRENGTH PSI EXTERIOR SLABS. CURBS, SIDEWALKS 4000 ALL OTHER CONCRETE (0.0.0.) 3000 DENSITY PCF 145 145 2. SLUMP OF CONCRETE SHALL NOT EXCEED 4" UNLESS A HIGH RANGE WATER- REDUCING ADMIXTURE IS USED. THE SLUMP OF CONCRETE PRIOR TO ADDITION OF A HIGH RANGE WATER- REDUCING ADMIXTURE SHALL NOT EXCEED 4. TH6 SLUMP OF CONCRETE CONTAINING A 0100 RANGE. WATER- REDUCING ADMIXTURE SHALL NOT EXCEED 10 ". 4. CONCRETE EXPOSED TO WEATHER SHALL BE AIR - ENTRAINED. AIR CONTENT SHALL BE BETWEEN 4 AND 8 PERCENT. THE NOMINAL MAXIMUM AGGREGATE SIZE SHALL BE A MINIMUM OF 3/4 14 ON FMI M PORTLAND WNG ENT AB CLON LT Y A8 TN OC CONCRETE HALL SPECIFIED MINIMUM CEMENT CONTENT (POUNDS PER CUBIC YARD) COMPRESSIVE STRENGTH NON -AIR ENTRAINED AIR ENTRAINED (PSI) CONCRETE CONCRETE 3000 470 517 4000 564 611 5. CONTRACTOR SHALL SUBMIT CONCRETE MIX DESIGNS FOR REVIEW WELL IN ADVANCE OF CONCRETE PLACEMENT. CONCRETE 1118 DE000 SHALL INCLUDE ALL STRENGTH DATA NECESSARY TO SHOW COMPLIANCE WITH THE PROJECT SPECIFICATIONS FOR EITHER THE TRIAL BATCH OR FIELD EXPERIENCE METHOD AND SHALL BE CERTIFIED BY AN ENGINEER REGISTERED m THE STATE WHERE THE STRUCTURE 15 LOCATED REINFORCING SHALL CONFORM TO ASTM A615, GR60, UNLESS NOTED OTHERWISE. _. WELDED WIRE FABRIC SHALL CONFORM TO ASTM .8185._. E. ALL REINFORCING SHALL BE DETAILED, FABRICATED AND PLACED. IN ACCORDANCE VATH AO DETAILING MANUAL 1988 (SP -66). •0. ALL REINFORCING SHALL BE SUPPORTED IN FORMS. SPACED WITH NECESSARY ACCESSORIES AND SHALL BE SECURELY W1RE0 TOGETHER, IN ACCORDANCE .11TH CRSI 'MANUAL OF STANDARD PRACTICE" (1986). MINIMUM CONCRETE COVER. UNLESS NOTED OTHERWISE: UNFORMED SURFACE IN CONTACT WITH THE GROUND. 3 IN. FORMED SURFACES EXPOSED TO EARTH OR WEATHER. ,q6 BARS AND LARGER 2 IN. Ifs BARS AND SMALLER i -7/2 IN. FORMED SURFACES NOT EXPOSED TO EARTH OR WEATHER: BEAMS, GIRDERS, AND COLUMNS 1 -1/2 IN. SLABS, WALLS, AND JOISTS :111 4 BARD S XA18 8 S5 LLER 1 -13/2 INN. . •_. LAP SPLICES SHALL BE IN ACCORDANCE VAN THE FOLLOWING TABLE, UNLESS NOTED OTHERWISE. WHERE CLASSES ARE NOT CALLED OUT ON DRAWINGS. USE CLA55 SPLICES. TENSION SPLICES (INCHES) TA OP BARS C A OTHER B BARS C COMPRESSION SPLICES (INCHES) 43 13 16 21 12 12 15 12 44 17 22 29 12 16 20 i5 #5 21 27 36 15 20 26 19 #6 27 35 46 19 25 32 23 #7 37 48 63 26 34 44 26 ,y8 48 63 82 35 46 60 30 p9 61 80 104 44 57 75 34 X10 78 101 132 56 73 95 38 #11 96 124 162 68 88 116 42 COMPRESSION DOWEL EMBEDMENT: 22 BAR DIAMETERS _ LAP WELDED WIRE FABRIC ONE SPACING OF CROSS QUIRES PLUS 2". BASE PATES, ANCHOR BOLTS, SUPPORT ANGLES, ETC., BELOW GRADE SHALL BE COVERED WITH A MINIMUM OF 3" OF CONCRETE. < CONCRETE WORK SHALL 8E SUBJECT TO QUALITY ASSURANCE TESTING AND INSPECTIONS. SEE QUALITY ASSURANCE GENERAL NOTES AND PROJECT PECIFICATIONS. REINFORCED MASONRY: 1 REINFORCED MASONRY SHALL HAVE A MINIMUM COMPRESSIVE STRENGTH. fm, OF 1500 85. MASONRY UNITS SHALL BE NORMAL WEIGHT BLOCK CONFORMING TO ASTM C9J. GRADE N. TYPE 1. AND SHALL HAVE A MINIMUM NET AREA COMPRESSIVE STRENGTH OF 1900 PO MORTAR SHALL CONFORM TO ASIA C270. 'Y'PE 5. GROUT SHALL CONFORM TO ASTM. C476. 2 REINFORCNG BARS SHALL CONFORM TO ASTM A615. GRADE 60. UNLESS NOTED OmERWSE. CONTINUOUS WIRE REINFORCING (JOINT REINFORCING SHALL BE GALVANIZED 690 9 ':PE FABRICATED UNITS WITH A SINGLE PAIR AF 9 GAUGE SIDE RODS AND 9 GAUGE CONTINUOUS WWECP DIAGONAL CROSS RODS FABRICATED FROM COLD - SPAM: STEEL WARE COMPLYING WITH ASTM 882. JOINT REINFORCING SHALL BE SPACED AT 76" C.C. VERTICALLY IN ALL MASONRY WALLS. 4 SEE ARCHITECTURAL DRAWINGS FOR LOCATION5 OF VERTICAL CONTROL JOINTS. HOR20N7AL BOND BEAM AND LINTEL REINFORCING SHALL BE CONTINUOUS ACROS5 ' IERTICAL CONTROL JOINTS. JOINT REINFORCING SHALL BE STOPPED EITHER 50E OF VERTICAL CONTROL JOINTS. 5 ALL REINFORCED CELLS. ALL CELLS BELOW GRADE AND ALL CELLS BELOW FINISH 81.00R SHALL BE GROUTED SOLID. 6 ALL EXTERIOR MASONRY WALLS ARE TO RECEIVE KOR -AL INSULATION. KOR -FIL INSULATION SHALL BE REMOVED FROM MASONRY UNIT5 THAT ARE TO BE USED FOR BOND BEAMS OR MASONRY LINTELS AND FROM MASONRY UNITS THAT ARE TO CONTAIN VERTICAL REINFORCING. UNLESS NOTED OTHERWISE_ 7. WHEN A FOUNDATION DOWEL DOES NOT LINE UP WTH A VERTICAL BLOCK CORE, IT SHALL NOT BE SLOPED MORE THAN ONE HORIZONTAL w 6 VERTICAL DOWELS MAY BE GROUTED 1NT0 A CELL IN VERTICAL ALIGNMENT. L -EN THOUGH IT 15 IN AN ADJACENT CELL TO THE VERTICAL WALL REINFORCING. 8- REINFORCNG STEEL SHALL BE SECURED IN PLACE BEFORE GROUTING STARTS. 9 SPLICED REINFORCING SHALL BE LAPPED 48 BAR DIAMETERS OR 24 INCHES. WHICHEVER IS GREATER. SPLICED BARS SHALL BE WIRED TOGETHER. 10. VERTICAL BARS SHALL BE HELD IN POSITION AT TOP AND BOTTOM AND AT 7NTER.VALS. NOT EXCEEDING 200 DIAMETERS OF THE REINFORCING, NOR 10 FEET. 11. VERTICAL REINFORCING BARS SHALL HAVE A MINIMUM CLEARANCE OF 3/4 Of AN INCH FROM THE MASONRY AND NOT LESS THAN ONE BAR DIAMETER BETWEEN BARS. 12. VERTICAL CELLS THAT WALL BE GROUTED SHALL HAVE A VERTICAL ALIGNMENT TO MAINTAIN A CONTINUOUS UNOBSTRUCTED CELL AREA NOT LESS THAN 2 1/2" X 3 13. GROUTING SHALL BE STOPPED 1 -1/2" BELOW THE TOP OF A COURSE SO AS TO FORM A KEY AT THE POUR JOINT. 1, GRQUTING OF MASONRY BEAMS OVER OPENINGS SHALL BE DONE IN ONE CONTINUOUS OPERATION. 15. ALL BOLTS. ANCHORS. ETC.. INSERTED IN THE WALLS, SHALL BE GROUTED SOLID INTO POSITION. 16. REINFORCED MASONRY HAS BEEN DESIGNED USING VALUES FOR CONSTRUCTION WITH SPECIAL INSPECTION. 17 REINFORCED MASONRY WORK SHALL BE SUBJECT TO QUALITY ASSURANCE TESTING AND INSPECTIONS. SEE QUALITY ASSURANCE GENERAL NOTES AND PROJECT SPECIFICATIONS. 2. STRUCTURAL STEEL: STEEL SHALL CONFORM TO THE FOLLOw1NG GRADES: ALL WF, CHANNELS, ANGLES. PLATES, ETC. (LINO) STRUCTURAL TUBE STEEL PIPE ANCHOR BOLTS BOLTS WELDING ELECTRODES A36 8500 Fry- -3456 (F)35 8307 67 E70X25 X ALL STRL21IRAL STEEL SHALL BE DETAILED, FABRICATED AND ERECTED IN ACCORDANCE WITH THE AISC CODE OF STANDARD PRACTICE (1986). EXCEPT A5 MODIFIED IN THESE NOTES AND THE PROJECT SPECIFICATIONS 3_ THE STEE.. STRUCTURE 15 A NON- SELF - SUPPORTING STEEL FRAME AND 15 DEPEND, T UPON DIAPHRAGM ACTION OF THE METAL ROOF DECK AND 0180 AND TO THE MASONRY WALLS FOR STABILITY AND FOR RESISTANCE TO WIND AND SEISMIC FORCES PROVIDE ALL TEMPORARY SUPPORTS REQUIRED FOR STABILITY AND FOR RESISTANCE TO VAND AND SEISMIC FORCES UNTIL THESE ELEMENTS ARE COMPLETE AND ARE CAPABLE OF PROVIDING THIS SUPPORT 4. THE FABRICATOR IS RESPONSIBLE FOR THE DESIGN OF ALL CONNECTIONS. CONNECTIONS SHOWN ON THE STRUCTURAL DRAWINGS ARE SCHEMATIC AND ARE ON, INTENDED TO SHOW THE RELATIONSHIP OF MEMBERS CONNECTED. CONNECTI ON DETAILS INDICATED ON THE DRAWINGS SHALL BE INCORPORATED INTO FABRICATOR'S CONNECTION DESIGN SEE SPECIFICATIONS. ALL SHOP DRAWINGS SHALL BE SIGNED AND SEALED BY THE FABRICATOR'S ENGINEER WITH THE ENGINEER'S SEAL FOR THE STATE _ WHERE THE STRUCTURE IS LOCATED - ENGINEER'S SEAL MAY BE QUALIFIED FOR DESIGN OF CONNECTIONS ONLY." 5. 6. SPLICING OF STEEL MEMBERS, UNLESS SHOWN ON THE DRAWINGS, I5 PROHIBITED WITHOUT WRITTEN APPROVAL OF THE ARCHITECT. UNLESS NOTED OTHERWISE, BEAMS SHALL BEAR 8" MINIMUM ON CONCRETE OR MASONRY_ UNLESS NOTED OTHERWISE, ANCHOR BEAMS TO MASONRY WITH Two (2) 3/4" DIAMETER ANCHOR BOLTS WITH 4" HOOK AND 1' -4" EMBEDMENT. 7. STRUCTURAL STEEL WORK SHALL BE SUBJECT TO QUALITY ASSURANCE TESTING AND INSPECTIONS. SEE QUALITY ASSURANCE GENERAL NOTES AND PROJECT SPECIFICA TONS. m9sco79 STEEL JOIST GIRDERS: 1. JOIST GIRDERS SHALL BE DESIGNED, FABRICATED AND ERECTED IN ACCORDANCE WITH THE STANDARD SPECIFICATIONS FOR JOIST GIRDERS (1989) OF THE STEEL JOIST INSTITUTE (SJI). 2. STEEL JOISTS GIRDERS SHALL BE DESIGNED BY THE MANUFACTURER: THE MANUFACTURER'S ENGINEER SHALL BE RESPONSIBLE FOR THE DEOGN, ADEQUACY AND SAFETY OF ALL STEEL JOIST GIRDERS. ALL SHOP DRAWINGS SHALL. BE SIGNED AND SEALED BY THE MANUFACTURER'S ENGINEER 8.110 THE ENGINEER'S SEAL FOR THE STATE WHERE THE STRUCTURE IS LOCATED. 3. EXCEPT WHERE ADDITIONAL DESIGN LOADS ARE SHOWN ON THE STRUCTURAL DRAWINGS, STEEL JOIST GIRDERS SHALL BE DESIGNED AS SIMPLY SUPPORTED PRIMARY MEMBERS WITH ALL LOADS EQUAL IN MAGNITUDES AND EVENLY SPACED ALONG JOIST GIRDER TOP CHORD. 4. ADDITIONAL DESIGN LOADS FROM ROOF TOP EQUIPMENT OR OTHER CONCENTRATED LOADS SHOWN ON THE DRAW.1NGS SHALL BE CONSIDERED AS COLLATERAL LOADS, THESE LOADS SHALL BE CONSIDERED IN THE DESIGN OF THE JOIST GIRDERS. REFER TO THE ARCHITECTURAL AND MECHANICAL DRAWINGS FOR LOCATIONS AND WEIGHTS OF EQUIPMENT. WHERE SUCH LOADS DO NOT OCCUR AT THE PANEL POINTS OF THE JOIST GIRDER, AUXILIARY FRAMING SHALL BE ADDED TO THE JOIST GIRDER OR THE TOP CHORD SHALL BE DESIGNED FOR THE EFFECTS OF THE LOAD. 5. JOIST GNGER DRS SHALL BE E IVIED 00 SUPPORT THE DESIGN LOADS WITHOUT 6. WHEN NET UPLIFT FORCES DUE TO WIND ARE SHOWM ON THE DRAWINGS, THE MANUFACTURER SHALL DESIGN THE JOIST GIRDERS AND CONNECTIONS OF THE JOIST GIRDERS TO THE SUPPORTING STRUCTURE FOR THE NET UPLIFT. 7. JOIST GIRDERS SHALL BE PROPORTIONED SUCH THAT THEY CAN BE ERECTED WITHOUT BRIDGING. 8. MINIMUM BEARING REQUIREMENT, UNLESS NOTED OTHERWISE: 4" ON STRUCTURAL STEEL 6" ON STEEL BEARING PLATES OVER MASONRY OR CONCRETE 9. UNLESS NOTED OTHERWISE: JOIST- GIRDERS SHALL BE ATTACHED TO - SUPPORTING STEEL WORK OR STEEL BEARING PLATES WITH TWO (Z) 1/4" FILLET WELDS (ONE EACH SIDE), 2' LONG, OR TWO (2) 3/4' DIAMETER BOLTS. 10. JOIST GIRDERS A COLUMN CEN1ERUNES SHALL BE BOLTED TO STRUCTURAL 11. NO OTHER LOADS SHALL BE PLACED ON THE JOIST GIRDER UNTIL THE STEEL JOISTS BEARING ON THIS ORDER ARE IN PLACE AND ATTACHED THERETO. 12. REPAIR OR REPLACE ALL DAMAGED JOIST GIRDERS. THE PROFESSIONAL OF RECORD SHALL BE THE SOLE JUDGE AS TO WHETHER A JOIST ORDER CAN BE REPAIRED OR MUST BE REPLACED. 13. STEEL JOIST GIRDER WORK SHALL BE SUBJECT G TO QUALITY ASSURANCE TESTNG AND INSPECTIONS. SEE QUALITY ASSURANCE GENERAL NOTES AND PROJECT SPECIFICATIONS STEEL JOISTS: 1. STEEL JOISTS SHALL BE DESIGNED, FABRICATED 640 ERECTED IN ACCORDANCE VATH THE 'STANDARD o Ei;IFICATI0NS FOR OPEN WEB STEEL JOISTS. -K- SERIES" (1989) OF THE STEEL JOIST INSTITUTE (51).. 2. STEEL JOISTS SHALL BE DESIGNED BY THE :MANUFACTURER. THE MAUFACTURER'S ENGINEER SHALL BE RESPONSIBLE FOR THE DESIGN, ADEQUACY AND SAFETY OF ALL STEEL JOISTS. : ALL SHOP DRAWINGS SHALL BE SIGNED AND SEALED BY THE MANUFACTURER'S ENGINEER WITH THE ENGINEER'S SEAL FOR THE STATE WHERE ME STRUCTURE IS LOCATED. 3. UNLESS OTHERWISE NOTED. STEEL JOISTS SHALL BE DESIGNED AS SIMPLY SUPPORTED, UNIFORMLY LOADED TRUSSES N1TH THE TOP CHORD BRACED AGAINST LATERAL BUCKUNG. THE UNIFORM DESIGN LOAD SHALL BE THE TOTAL SAFE UNIFORMLY DISTRIBUTED LOAD AS 58044 IN THE SJ1 .STANDARD LOAD TABLE. 4. WHEN NET UPLIFT FORCES DUE' TO WWND ARE SHOWN ON THE DRAWINGS, THE MANUFACTURER SHALL DESIGN THE JOISTS. BRIDGING AND CONNECTIONS OF THE JOISTS TO THE SUPPORTING STRUCTURE FOR THE NET UPLIFT. A SINGLE UNE OF BOTTOM CHORD BRIDGING MUST BE PROVIDED NEAR THEFRST BOTTOM. CHORD PANEL POINTS WHENEVER UPLIFT DUE TO WIND FORCES IS .SHOWN ON THE DESIGN DRAWINGS 5. WHEN NONUNIFORM OR CONCENTRATED LOADS ARE SHOWN- ON THE DRAWINGS. THE MANUFACTURER SHALL DESIGN THE JOISTS IN ACCORDANCE WITH PARAGRAPH 4.1 OF THE STANDARD SPECIFICATION FOR OPEN WEB STEEL JOISTS, K- SERIES. 6. STEEL JOIST BRIDGING SHALL BE PROVIDED IN ACCORDANCE WITH THE SJI SPECIFICATION. ALL BRIDGING AND BRIDGING. ANCHORS SHALL BE PLACED AND STEEL JOIST ENDS FIXED PRIOR TO THE APPLICATION OF ANY LOADS. BRIDGING THAT TERMINATES AT, OR IS INTERRUPTED BY, STRUCTURAL STEEL BEAMS, MASONRY WALLS OR CONCRETE WALLS SHALL BE ATTACHED THERETO. COORDINATE BRIDGING LOCATONS TO AVOID INTERFERENCE WITH ALL MECHANICAL, ELECTRICAL AND FIRE PROTECTION EQUIPMENT.. 7. MINIMUM BEARING REQUIREMENTS, UNLESS NOTED OTHERWISE: 2 -1/2' ON STURAL SEE 4' N STEEL BERUARINCTG PLAITE5L OVER MASONRY. OR CONCRETE 8. UNLESS NOTED OTHERWISE, STEEL JOISTS SHALL 8E ATTACHED TO SUPPORTING STEEL WORK OR STEEL BEARING PLATES E WITH (2) 1/8' FILLET WELD (ONE EACH SIDE) 1" LONG, OR WITH 1/2" DIAMETER BOLT. 9. STEEL JOISTS AT COLUMN. CENTER LINES SHALL BE BOLTED TO STRUCTURAL STEEL WITH 2 DIAMETER BOLTS. WHERE STEEL JOISTS DO NOTSPACE TO TOLUMN CEN R LINES; USE 80LTEDCONNECTIONS FOR THE STEEL JOIST CLOSEST TO THE CENTER UNE. 10. HOLES IN STEEL JOIST CHORDS WILL NOT BE PERMITTED, EXCEPT FOR BOLTED CONNECTIONS AT THE BEARING END OF THE STEEL JOIST. 11. ALL ITEMS SUCH AS MECHANICAL EQUIPMENT; DUCT. WORK, PIPES, CEWNG, FIXTURES, ETC. THAT ARE TO BE SUPPORTED OR HUNG FROM THE STEEL JOIST SHALL BE FRAMED WITH AUXILIARY FRAMING TO THE PANEL POINTS OF THE STEEL JOIST. METHODS OF FRAMING THAT INDUCE - BENDINGTO THE STEEL JOIST CHORDS OR WEB MEMBERS WILL NOT BE PERMITTED. 12. REPAIR OR REPLACE ALL DAMAGED STEEL JOISTS. THE PROFESSIONAL OF RECORD SHALL BE THE SOLE JUDGE AS TO WHETHER A JOIST CAN BE REPAIRED OR MUST BE REPLACED. 13. STEEL JOIST WORK SHALL BE SUBJECT TO QUALITY ASSURANCE TESTING AND INSPECTIONS. SEE QUAUTY ASSURANCE GENERAL NOTES AND PROJECT SPECIFICATIONS METAL ROOF DECK: 1. METAL ROOF DECK SHALL COMPLY VAIN THE REQUIREMENTS OF THE STEEL DECK INSTITUTE SPECIFICATIONS AND COMMENTARY FOR STEEL ROOF DECK (1989). 2. METAL ROOF DECK AND ITS ATTACHMENT TO TH6 STRUCTURE. SHALL BE DESIGNED BY. THE MANUFACTURER. THE MANUFACTURER'S ENGINEER SHALL BE RESPONSIBLE FOR THE .DESIGN; ADEQUACY AND SAFETY OF ALL METAL ROOF DECK ALL SHOP DRAWINGS SHALL BE SIGNED AND SEALED BY THE. MANUFACTURER'S ENGINEER' WITH THE ENGINEER'S SEAL FOR THE STATE WHERE THE STRUCTURE IS LOCATED. 3. METAL ROOF DECK SHALL BE CONFIGURATION. DEPTH AND MINIMUM GAGE AS SHOWN ON THE DRAWINGS. ATTACHMENT TO THE SUPPORTING STRUCTURE SHALL BE AS SHOWN ON THE DRAWINGS AS A MINIMUM. SEE ROOF PLAN NOTES. 4. DO NOT HANG OR SUPPORT ANY LOADS FROM METAL ROOF DECK. 5. METAL ROOF DECK SHALL BE CONTINUOUS OVER A MINIMUM OF THREE SPANS. 6. METAL ROOF DECK WORK SHALL BE SUBJECT TO QUALITY ASSURANCE TESTING AND INSPECTIONS. SEE QUALITY ASSURANCE GENERAL NOTES AND PROJECT SPECIFICATIONS. MISCELLANEOUS: 1. THESE GENERAL NOTES SUPPLEMENT THE PROJECT SPECIFICATIONS. REFER TO PROJECT SPECIFICATIONS FOR ADDITIONAL REQUIREMENTS. 2. STRUCTURAL DRAWINGS ARE INTENDED TO BE USED WITH ARCHITECTURAL AND MECHANICAL DRAWINGS. CONTRACTOR 15 RESPONSIBLE FOR COORDINATING SUCH REQUIREMENTS INTO THEIR SHOP DRAWINGS AND WORK. 3. NO OPENINGS SHALL BE MADE IN ANY STRUCTURAL MEMBER WITHOUT THE WRITTEN APPROVAL OF THE PROFESSIONAL OF RECORD. 4. NO CHANGE IN SIZE OR DIMENSION OF STRUCTURAL MEMBERS SHALL BE MADE WITHOUT THE WRITTEN APPROVAL OF THE PROFESSIONAL OF RECORD. 5. OPENINGS DRAWINGS. WINGS. SS ON A SIDE ARE GENERALLY NOT SHOWN A ON THE STRUCTURAL DRAWINGS. REFER TO ARCHITECTURAL AND MECHANICAL DRAWINGS FOR SUCH OPENINGS 6. THE CONTRACTOR IS RESPONSIBLE FOR LIMITING THE AMOUNT OF CONSTRUCTION LOAD IMPOSED UPON STRUCTURAL FRAMING. CONSTRUCTION LOADS SHALL NOT EXCEED THE DESIGN CAPACITY OF THE FRAMING AT THE TIME THE LOADS ARE IMPOSED. 7. THE STRUCTURE 15 DESIGNED TO FUNCTION AS A UNIT UPON COMPLETION. THE CONTRACTOR I5 RESPONSIBLE FOR FURNISHING ALL TEMPORARY BRACING AND/ OR SUPPORT THAT MAY BE REQUIRED AS THE RESULT OF THE CONTRACTOR'S CONSTRUCTION METHODS AND /OR SEQUENCES. 8. DO. NOT. SCALE THESE DRAWINGS, USE DIMENSIONS. 9. CONTRACTOR'S CONSTRUCTION AND /OR ERECTION SEQUENCES SHALL RECOGNIZE AND CONSIDER THE EFFECTS OF THERMAL "MOVEMENTS OF STRUCTURAL ELEMENTS DURING THE CONSTRUCTION PERIOD. {1 10. THE CONTRACTOR SHALL : INFORM THE PROFESSIONAL OF RECORD IN WRITING OF y ANY DEVIATION FROM THE CONTRACT DOCUMENTS THE CONTRACTOR SHALL NOTE BE RELIEVED OF THE RESPONSIBILITY OF SUCH DEVIATION BY THE PROFESSION, . OF RECORD REVIEW OF SHOP DRAWINGS, PRODUCT DATA, ETC., UNLESS THE CONTRACTOR HAS SPECIFICALLY INFORMED THE PROFESSIONAL OF RECORD OF SUCH DEVIATION AT THE TIME OF SUBMISSION, AND THE PROFESSIONAL OF {t RECORD HAS OVEN WRITTEN APPROVAL TO THE .SPECIFIC DEVIATION. QUALITY ASSURANCE: I. THE OWNER WALL EMPLOY AND PAY FOR THE SERVICES OF AN INDEPENDENT TESTING AGENCY TO PROVIDE QUALITY ASSURANCE TESTING AND INSPECTIONS. THE TESTING AGENCY SHALL BE LICENSED IN THE STATE WHERE THE STRUCTURE IS LOCATED. AND ALL TESTING AND INSPECTIONS SHALL BE PERFORMED UNDER THE SUPERVISION OF AN ENGINEER REGISTERED IN THE STATE WHERE THE STRUCTURE IS LOCATED. FAILURE OF QUALITY ASSURANCE TESTING AND INSPECTIONS TO DETECT ANY DEFECTIVE WORK OR MATERIAL SHALL NOT IN ANY WAY PREVENT LATER REJECTION WHEN SUCH DEFECT IS NOTED NOR SHALL IT OBLIGATE THE OWNER'S REPRESENTATIVE FOR FINAL ACCEPTANCE. 2. 3. 4. 5. 6. 7. 5EE SPECIFICATIONS FOR SPECIFIC REQUIREMENTS FOR QUALITY ASSURANCE TESTING' AND INSPECTION 042 CONCRETE - SECTION 3A REINFORCED MASONRY - SECTION 4A. STRUCTURAL STEEL - SECTION 5A. STEEL JOIST GIRDERS - SECTION 5B. STEEL JOISTS - SECTION 5C. METAL ROOF DECK - SECTION 50. SEE CIVIL DRAWINGS AND DIVISION 2 SPECIFICATONS FOR QUALITY ASSURANCE TESTING AND INSPECTIONS FOR FOUNDATION WORK. THE TESTING AGENCY AND ITS REPRESENTATIVES ARE NOT AUTHORIZED TO REVOKE. ALTER, RELAX. SENLARGE OR RELEASE ANY PORTION OF THE WORK, PERFORM ANY DUTIES OF THE CONTRACTOR, Oft BE A PARTY TO SCHEDULING OF WOR, THE CONTRACTOR SHALL NOTFY THE TESTING AGENCY AND THE OWNER'S REPRESENTATIVE A MINIMUM OF 24 HOURS IN ADVANCE OF ALL WORK REQUIRING QUAUTY ASSURANCE TESTING AND INSPECTIONS AND ALL REASONABLE FACILITES SHALL BE MADE AVAILABLE FOR TECHNICIANS.. RECORDS 0 INSPECTIONS SHALL BE KEPT AVAILABLE TO THE BUILDING TN 06 L DURING PROGRESS O THE WORK AND FOR Two YEARS AFTER COMPLETION OF THE PROJECT. RECORDS SHALL BE PRESERVED BY THE INDEPENDENT TESTING AGENCY. $pECIAL : IN SPECTIQNS: 1. THE OWNER WILL EMPLOY ME SERVICES OF ONE OR MORE SPECIAL INSPECTORS TO PROVIDE SPECIAL INSPECTIONS DURING CONSTRUCTION COMPLYING TO SECTION 306 OF THE UNIFORM BUILDING CODE FOR THE FOLLOWING: A. CONCRETE: PROVIDE INSPECTI(NS DURING THE TAKING OF TEST SPECIMENS AND PLACING OF REINFORCED CONCRETE (EXCEPT SLABS ON GRADE). B. REINFORCING STEEL: PROVIDE INSPECTIONS FOR CONFORMANCE VATH THE APPROVED PLANS PRIOR TO CLOSING OF FORMS OR THE DEUVERY OF CONCRETE TO THE JOB 0TE. WELDING PROVIDE PERIODIC INSPECTIONS OF ALL WELDING INCLUDING WELD1NG GF METAL ROOF DECK. INSPECTOR SHALL CHECK QUAUFICATIONS OF WELDERS AT START OF THE WORK AND MAKE FINAL INSPECTION OF ALL WELDS FOR COMPUANCE PRIOR TO COMPLETION OF WELDING. INSPECTION 15 NOT REQUIRED FOR WELDING DONE IN AN APPROVED FABRICATOR'S SHOP. D. HIGH STRENGTH BOLTING: PROVIDE INSPECTIONS PER UBC STANDARD 27 -7 FOR BOLTS CONSIDERED AS NOT BEING 5UP CRITICAL NOR SUBJECT TO DIRECT TENSION. E. SPECIAL GRADING, EXCAVATION AND FILLNG: PROVIDE INSPECTIONS TO SATISFY REQUIREMENTS OF CHAPTER 29 AND CHAPTER 70 (APPENDIX) OF THE UNIFORM BUILDING CODE DURING EARTHWORK EXCAVATIONS. GRADING AND FILLING OPERATIONS. 2. THE CONTRACTOR WILL EMPLOY THE SERVICES OF ONE OR MORE SPECIAL INSPECTORS ACCEPTABLE TO THE OWNER TO PROVIDE SPECIAL INSPECTIONS DURING CONSTRUCTION COMPLYING TO SECTION 306 OF THE UNIFORM BUILDING CODE FOR THE FOLLOWING: A. STRUCTURAL MASONRY: PROVIDE PERIODIC INSPECTIONS DURING PLACING OF MASONRY UNITS, PLACEMENT OF REINFORCING, - INSPECTION OF GROUT SPACE, IMMEDIATELY PRIOR TO CLOSING OF CLEANOUTS, AND DURING GROUTING OPERATIONS. SAMPLE AND TEST MASONRY UNITS FOR COMPRESSION STRENGTH IN ACCORDANCE WITH ASTM C140, ONE SAMPLE FOR EACH 5000 SQUARE FEET OF WALL AREA SAMPLE: AND TEST GROUT FOR COMPRESSIVE STRENGTH IN ACCORDANCE WITH ASTM C1019, ONE SAMPLE FOR EACH 5000 SQUARE FEET OF WALL AREA. 3. THE SPECIAL INSPECTOR SHALL BE A QUAUFIED PERSON WHO SHALL DEMONSTRATE HIS COMPETENCE, TO THE SATISFACTION OF THE BUILDING OFFICIAL FOR INSPECTION OF THE PARTICULAR TYPE OF CONSTRUCTION OR OPERATION REQUIRING SPECIAL INSPECTION.: 4. DUTIES AND RESPONSIBILITIES OF 'ME SPECIAL: INSPECTOR: A. THE SPECIAL - INSPECTOR: SHALL OBSERVE THE WORK 695454ED' FOR CONFORMANCE WI'!H THE APPROVED DESIGN DRAWINGS AND SPECIFICATIONS. B. THE SPECIAL INSPECTOR SHALL FURNISH INSPECTION REPORTS TO THE BUILDING OFFICIAL, THE PROFESSIONAL OF RECORD, AND THE CONTRACTOR. ALL DISCREPANCIES SHALL BE BROUGHT TO THE IMMEDIATE .ATTENTION OF THE CONTRACTOR FOR CORRECTION, THEN, IF UNCORRECTED, TO THE PROPER. DESIGN AUTHORITY AND TO THE BUILDING OFFICAL. C. THE SPECIAL INSPECTOR SHALL . SUBMIT A FINAL SIGNED REPORT STATING WHETHER THE WORK REQUIRING SPECIAL INSPECTION WAS, TO THE BEST OF THE INSPECTOR'S KNOWLEDGE, IN CONFORMANCE WITH THE APPROVED PLANS AND SPECFICATIONS AND THE APPUCABLE WORKMANSHIP PROVISIONS OF THE CODE... 5. WHERE SPECIAL INSPECTION REQUIREMENTS DUPLICATE THE REQUIREMENTS OF SPECIFIED QUALITY ASSURANCE TESTING, DUPUCATE INSPECTIONS SHALL NOT BE REQUIRED. FILE COPY understand that the Plan Check approvals are ,o: l to errors and omissions and approvatof ,; does not authorize the violation of any •,rted cods or ordinance. % ReC8I o ff' :19r's top 4ofa... rovedter_► PJU1L01 By Date Permit No. • Q MECHANICAL ELECTRICAL ( PLUMBING *GAS PIPING rIT( OF 'VI LA '..DING DMA cn- ,PRE1VED OF TUI(BVILA MAY 1 7 1995 PERMIT CENTER Revisions No Date Description 2 3/10/92 ADDENDUM D 3 3/19/92 ADDENDUM E Drawing References No Drawings 52 FRAMING / FOUNDATION PLAN S3 FRAMING / FOUNDATION DETAILS ISSUED FOR PERMITS: I 02 -12 -92 ISSUED FOR BIDS: 01 -31 -92 CADO NAME: TP91501 PROJECT NO.: 262991 DRAWN BY: CHECKED BY: PROTOTYPE DESIGNATION: 1991 REV. 3.91 THE NV BD( UROL" I' 11111, I 1,1 I f I 11,1∎1IJ'� 50 MONROE PLACE RAPIDS GRAND M CHIGAN49503 TELEPHOFAX((6116)2235-6132 6 toys •w vs® National Office 461 From Road Paramus, NJ 07652 (201) 599 -7800 GEOFFREY This drawing is the Exclusive Property of TOYS "R" US. The information shown may not be used nor the Drawings Reproduced without permission of TOYS "R" US. Location TU K WI LA, WA. Drawing Title GENERAL NOTES Scale AS NOTED Date 01 -31 -92 Sheet no. 1 \ 191 Tw \T91Twso2 ROOF PLAN NOTES: 1, SEE SHEET 51 FOR GENERAL NOTES. 2. SEE SHEET 52 FOR TYPICAL DETAILS. 3. TOP OF STEEL (T.0.5.) EQUALS TOP OF STEEL JOIST /UNDERSIDE OF METAL DECK. BEAMS AND JOIST GIRDERS REFERENCED A/- FROM TOP OF STEEL. 4. METAL ROOF DECK SHALL BE 20 GAGE. 36" WIDE, 1 1/2° DEEP. VIDE RIB ROOF DECK AND SHALL BE CONNECTED TO FRAMING MEMBERS AS FOLLOWS: (DIAPHRAGM SHEAR = 292 PLF) A. TO ALL TRANSVERSE SUPPORTS. 5/8" DIA, PUDDLE WELDS. 4 PER SHEET. (36/4 PATTEN) B. SIDE SEAMS #10 SCREWS (BUILDER). 4 PER SPAN. 5. STEEL JOISTS IDENTIFIED ON PLAN AS "SP" SHALL BE DESIGNED FOR THE UNIFORM LOAD CAPACITY (AS SPECIFIED IN THE SJI STANDARD LOAD TABLES) IN ADDITION TO THE CONCENTRATED LOADS SHOWN ON THE PLAN. STEEL JOIST GIRDERS IDENTIFIED ON PLAN AS "SP° SHALL BE DESIGNED FOR THE UNIFORM PANEL P0150 LOADS SHOWN ON THE DRAWINGS IN ADDITION TO THE CONCENTRATED LOADS SHOWN ON PLAN. ALL ITEMS .04 AS MECHANICAL EOIPMENT, DUCT WORK. PIPES, CEILINGS. FIXTURES, ETC. THAT ARE TO BE SUPPORTED OR HUNG FROM THE STEEL JOIST SHALL BE FRAMED WITH AUXILIARY FRAMING TO THE PANEL POINTS OF THE JOIST (SEE TYPICAL JOIST STRUT DETAIL). METHODS OF FRAMING THAT INDUCE BENDING TO THE JOIST CHORD OR WEB MEMBERS WILL NOT BE PERMITTED. COORDINATE BRIDGING LOCATIONS SO AS NOT TO INTERFERE WITH ANY MECHANICAL EQUIPMENT. 6. STEEL JOIST CAMBER SHALL BE PROVIDED AND SHALL CONFORM TO SECTION 4.7 OF THE SJI SPECIFICATIONS. STEEL JOIST GIRDER CAMBER SHALL CONFORM TO THE SJI SPECIFICATIONS. 7. APPROXIMATE CORNER WEIGHTS OF ROOF TOP EQUIPMENT ARE SHOWN ON PLAN. VERIFY ALL LOADS, LOCATIONS, CURB SIZES AND OPENING SIZES WITH MECHANICAL CONTRACTOR PRIOR TO FABRICATION. ADJUST SPACING aF STEEL JOISTS AS REQUIRED FOR MECHANICAL OPENINGS. SEE TYPICAL FM SUPPORT DETAIL FOR FRAMING. ROOF DEAD LOADS BUILT -UP ROOF W /GRAVEL INSULATION METAL DECK JOISTS MECH. /ELEC. / MISC. CEILING / DISPLAY = 6.0 = 2.0 = 2.0 = 3 -0 = 4.0 = 4.0 PSF PSF PSF PSF PSF PSF TOTAL DEAD LOAD ROOF LIVE LOADS = 21.0 PSF METAL DECK /JOISTS. = 25 PSF JOIST GIRDERS /BEAMS /COLUMNS /FOOTINGS TRIBUTARY AREA 0 TO 200 S0. FT. = 25 PSF TRIBUTARY AREA 201 TO 600 SQ. FT. = 25 PSF TRIBUTARY AREA OVER 600 SQ. FT. = 25 PSF UPLIFT DUE TO WIND NET UPLIFT JOISTS = 0 PSF JOISTS GIRDERS = 0 PSF MEZZ. DEAD LOADS 2.5" CONC. DECK DECK JOIST MECH. /ELEC. / MISC. CEILING / DISPLAY = 32.0 PSF = 2 -0 PSF = 3.0 PSF = 4.0 PSF = 4.0 PSF TOTAL DEAD LOAD MEZZ. LIVE LOADS = 45.0 PSF = 100 PSF STEEL LINTEL SCHEDULE LEAR SPAN CLEAR 12 BLOCK OR 8" BLOCK + 4" BRICK 8" BLOCK 6-4 ".. OR LESS (3) L3 1/2X3 1 /2X1/4 . (2) L3 1/2X3 1 /2x1/4 OVER 6' -4" TO 10' -4" W8X10 W/ 11X1/4 PLATE W8X10 W/ 7X1/4 PLATE O R 10' -4" TO 12' -4" W8X13 W/ 11X1/4 PLATE W8X10 W/ 7X1/4 PLATE CLER 12' -4" TO 14' -4" W8X21 W/ 11X1/4 PLATE W8X13 W/ 7X1/4 PLATE 4" GRAVEL LINTEL NOTES: 1. LINTEL SIZES SHOWN ARE DESIGNED TO SUPPORT MASONRY WALL ONLY ASSUMING ARCHING ACTION (AT 45 DEGREES) WITHOUT SUPERIMPOSED FLOOR OR ROOF LOADS. 2. LINTELS SHALL BE SHORED DURING CONSTRUCTION UNTIL THE MASONRY HAS ATTAINED SUFFICIENT STRENGTH TO CARRY ITS OWN WEIGHT (24 HOURS MINIMUM). 3, LINTEL SIZES SHOWN APPLY WHERE LINTEL SIZES ARE NOT OTHERWISE SHOWN ON THE DRAWINGS. 4. WHERE W8 BEAMS WITH PLATES ARE USED, PLATE SHALL BE CENTERED ON BEAM AND SHALL EXTEND FULL LENGTH OF BEAM_ WELD PLATE TO BEAM WITH 3/16" FILLET WELDS 1 1/2" LONG SPACED AT 12" O.C. EACH SIDE. 5. SEE "TYPICAL LINTEL BEARING" DETAIL (SHEET 53) FOR END BEARING. WALL ANCHORS AND SEISMIC REINFORCING 5. NOTE THE NEW OPENINGS iN THE EXISTING WALLS FOR DOOR_ 27 AND 28 LOCATED IN THE SOUTHEAST AND NORTHWEST CORNERS OF THE BUILDING. Thq5 -jc/ SLAB SCHEDULE LOCATION THICKNESS & REINF. SUBBASE S_AB ON GRADE 4" CONC. SLAB ON GRADE REINE. W /6X6- W1.4XW1.4 W.W.F. 6 MIL VAPOR BARRIER & 4' GRAVEL SUBBASE MEZZ. SLAB 2 1/2° CONC. SLAB W/ (i) LAYER 6x6 -W1.4 X 4 WW F. SIDEWALK 4" CONC. SLAB ON GRADE REINF. W /6x6 -WI 4 X W1.4 W IN 4" GRAVEL FOUNDATION PLAN NOTES: SEE SHEET 51 FOR GENERAL NOTES 2. SEE SHEET 53 FOR TYPICAL DETAILS 3 ALL ELEVATIONS BASED ON FINISH FLOOR ELEVATION OF 100' -0° FOR REFERENCE ONLY. SEE SITE PLAN FOR ACTUAL FINISH FLOOR ELEVATION. 4. TOP OF INTERIOR FOOTING AND TOP OF PILASTER ELEVATION = 99' -4" UNLESS NOTED OTHERWISE. PLAN \D EXIST. CONT. 12 "x1' -8" FOOTING. TOF =97'0"(VERIFY) EXIST. 12° FNDN. WALL. TOW= 99' -4" 114 DOWELS. GROUT INTO EXIST. FOOTING. 7-7 EXIST. W14x22 SEE DET12 ON S3 FOR FIELD CONNECTION OF EXIST. W12x16 TO EXIST. BEAMS MODIFY EXIST. 8" JOISTS SEE DET. 3 ON S3. EXIST. w1 <x22 iW10x12 EOI:Twl022 l' 9' -5 1 /2" EXIST. W12x16 TO BE MOVED 4' -0 ° +- SOUTH FROM EXISTING LOCATION. T.O.B. ELEV. -3' TO ALLOW FOR 3" JOIST SEAT.... SEE DET. 11 ON S3 FOR FIELD CONNECTION OF NEW W10x12 TO EXIST. BEAMS NOTE: FIELD VERIFY REQUIRED OPENING FOR CHUTE AND STAIR. ADJUST AS NEEDED. SEE DET. 11 ON S3 FOR FIELD CONNECTION OF NEW W10x22 70 EXIST. BEAMS MODIFY EXIST. 14" JOISTS SEE DET. 3 ON 53. -9, 1/2 1/2" EXIST. W16x31 T 0 B ELEV. -3" TO ALLOW FOR 3" JOIST SEAT. MEZZ. FRAMING PLAN NORTH SCALE: 1/16"=1. -0" 43 U- SHAPED TIE AROUND ANCHOR =15" BOLTS IN MORTAR JOINT. - BEAM TO BEAR CONT. ON NEW BLK. GROUT AS NECESSARY W12x16 (2) 1/4 "x10 "x6" P (1 EACH SIDE) FIELD DRILL HOLES IN EXIST W12 TO ACCOMMIDATE NEW 3/4" o ANCHORS (1) p5 VERT. FULL - HEIGHT OF WALL (W/ #4 DWL. INTO FTG. TO MATCH) GROUT CELL SOLID (2 3/4" DIA. ANCHO BOLTS W/ 4" HOOK. EMBEDDED 1' -4" INTO WALL BLOW (1) p5 VERT. (W/ #4 INTO FTG. TO MATCH) GR UT CELL SOLID 150# ® EA. CORNER OF RTU. REFER TO ROOF PLAN, AND NOTE 7 ON THIS SHEET. 2 (2) 3/4!''''87:1718A. WAIN CCHOONRTS . 1E/A4 . "xE1N1D P® L . B EARING. POCKET EXIST. WALL TO ACCOMMODATE NEW LINTEL. GROUT MIN. TWO COURSES BELOW BRNG. PLAN NORTH FOUNDATION PLAN SCALE: 1/16"=1.-0" 23' S° SEE DET. 12 ON S3 FOR FIELD CONNECTION OF EXIST. W12x16 TO EXIST. BEAMS T.O.B. ELEV. -3" TO ALLOW FOR 3° JOIST SEATS. 23' -5" SEE DET. 11 ON S3 FOR FIELD CONNECTION OF NEW W10x12 TO EXIST. BEAMS NOTE: SEE ARCHITECTURAL FOR LOCATION OF NEW AND EXISTING MASONRY WALLS. EXIST. W12x16 EXIST. W12x16 •'JD OF CONC E., WALL ROOF FRAMING PLAN SCALE: NONE i \O t� ti= EXIST. W24x84 I EXIST. W24152 EXIST. W12x16 TO BE MOVED 3' -1 " += MODIFY EXIST. 14" JOISTS WEST FROM EXISTING LOCATION.. SEE DET. 3 ON S3. PLAN ST W1 Ox12 12' -11 5/8" - EXIST. W8 NEW TS 4x4x1/4 COL. W/ 3/4 "x10 "x10" B.P. NEW 3'- 0 "43' -0 "x12" FTNG. W/ (3) #5's EA. WAY SEE DET. 4 ON A3 NEW 8K1 STEEL JOISTS NEW 2.5" CONC. SLAB ON .5" METAL DECK. REINFORCE WITH 6x6- W1.4x1.4 WIRE MESH. REINF. EXIST. W18x40. SEE DET. 9 ON 53. NOTE: FIELD VERIFY REQUIRED OPENING FOR CHUTE AND STAIR. ADJUST AS NEEDED. NORTH 17 COL. SEE DET. 10 EXIST. C12x20.7 ■ MEZZ. FRAMING PLAN SCALE: 1/16"=1.-0" ON S3. EXIST. IC12x20.7 0 EXIST. C12 20.7 EXIST. C12x20.7 E C12x20.7 TOS = 123'0^ • WI 12 W10x12 W10x1.. y 11111 M WAS i pp77WWypp ® �r .... v LINE o o 8 EQ. SPACES o7' -10 3/16" = 62' -9 1/4" 2.9 RO RE X L BE W10x12 W10x12 TO5 = 123'4" 9' -5 1/2 12' -11 5/8" PLAN 6cxxpeee866 7.2 \PI NORTH ROOF FRAMING PLAN SCALE: 1 /16 " =1' -0" O O RECEIVED TUKWI Clry OF LA MAY 1 7 1995 PERMIT CENTER Dote 2 3/19/92 3 3/19/92 4 6/22/92 Revisions Description ADDENDUM D ADDENDUM E BULLETIN j6 Drawing References No Drawings 51 GENERAL NOTES S2 FRAMING / FOUNDATION PLAN S3 FRAMING / FOUNDATION DETAILS ISSUED FOR BIDS: 01 -31 -92 ISSUED FOR PERMITS: 02 -12 -92 CADD NAME: TP9ISO5 PROJECT NO.: 262991 DRAWN BY: BTH CHECKED BY: PROTOTYPE DESIGNATION: 1991 REV. 3.91 THE WBDC GROUP 10:'L 112L:( TI 01:. I'I ..INNINI�- I N1 INI 1 1)51, IN 1101(111, 50 MONROE PLACE GRAND RAPIDS TELEPHONE (616) 235 -6000 MICHIGAN 49503 FAX (616) 235 -6132 r•vs .A. vs Notional Office 461 From Road Paramus, NJ 07652 (201) 599 -7800 GEOFFREY This drawing is the Exclusive Property of TOYS "R" US. The information shown may not be used or the Drawings Reproduced without permission of TOYS "R" US. Location TUKWILA, WA. Drawing Title FRAMING / FOUNDATION PLAN Scale AS NOTED Dote 01 -31 -92 Sheet no. S 2 /4_,R) SAW ;_- OR S .-APED CONTROL ,ON'c N-RACTO -S OP_.ON; SLAB JN GRADE W W F �- _.PANS,ON JOINT M4-_ t- ___ X NOTE: SAW CUT SLAB 'MTHIN 12 ■O..;RS AFTER SLAB HAS BEEN PLAE=D. CONTROL JOINT S_A? :,N GRADE - SLAB JOINT DETAILS 3/16/ A - A TYPICAL COLUMN BASE CL 103. -A- 11 raj NY CONCR RcS �fr� SEE DW � ilnu� '. SLAB ON DE - �Ir SSE SL - HEDL�! E -erM .E ill r ri • A B — B p5 0 32" 0 C. 1/2" FREMOLDED FILLER SIDEWA., -SEE SLAB SCH DuLE 2 T.S. CO__ M•. BOND C 's w/ (,) ac _ONT_ BETWEEN __-,_AANS 12"x16' CONC ,ASTER REINF W/ A ) #6 VERT DWLS & g3 TIE_ 0 12" OC } `COTE: OMIT PILAS'ER IF -OP OF =TG. EL, = DALE MATCH ALTERNA -E �CTC SCALE: 1/2 " =1• -0" 4,0 TYPICAL RTU SUPPORT _ON'CRE' 3_ CK MASONRY WALL TS 4%4x1 /4 WITH 3/4 "X10 "X10" BRNG, PLATE W/ (4) 3/4" DIA. ANCH. BOLTS (SEE DETAIL 4 ON A3) 4 ANCHOR BOLT BASE PLATE 11 /: TYP 2 ANCHOR BOLT BASE PLATE TS 5%5X5/16" W TH 3/4 X7 "X11" BRNG. PLATE w/ (2) 3/4" DIA. ANCH. BOLTS 0 TYPICAL BASE PLATE DETAILS (1) g5 CONT OVER OPENING: EXTEND 2a" PAST Ea. SIDE OF OPErvING. LINTEL AT GRID LINE 5.2 ONLY ' '31.6 TYPICAL STEPPED FOOTING DETAIL NOTE: TOP FLANGE OF BMS. & PLATES NOT SHOWN FOR CLARITY. STEEL LINTEL. SEE SCHEDULE g3 - SHAPED TIE APOLND ANCHOR 15 Ba-s IN MORTAR JON BOND BEAMS w • ; gfi GON- A' -p- MA+ ._'- SPACING 5.3.,/A ( :ANT USE FULL PENETRATION ' WELD FIE_C SAUCES BS @ 4-0' 0 0. IN VEP' _300 SLOT ' E HOLES. g EACH AN'C_'R BOLT DP ? _ AN , -WELD DECK ", ANGLE , 5 ?EYM A BEAM BEYONC BOND BEAM A ) #6 CO, BETWEEN :;_._Mks g6 0 32- 0. (CENTERED .N AF 48 EAF _ AME HERS INTC 2" BLOCK RS 3/4" GROUT 8 BEARING (I) g5 VERT =ULL- HEIGHT OF wAL_ (W/ A4 DWL INTO FTG. TO MUCH) GROU- CELL SOLID (2) 3/4" DIA. ANCHOR BOLTS W/ 4" HOOK. EMBEDDED 1' -4" INTO WALL BELOW %(1) T g5 VE/ 4). INO FTG. RT TO (WMATCH) DWL GROUT CELL SOLID TYPICAL LINTEL BEARING 12" CONS. BLOCK HORIZ. JT. REINF 16 "O.0 SIDEWALK SEE SLAB SCHEDULE E�. Ei g6 0 H32" .. FULL T. OE OC WALL VER' BOND SEAM W/ ' FULLHT - OF WALL SLAB ON GRADE SEE SLAB SCHEDULE g4 . DwtS. TO MATCH VERT. ALTERNATE HKS. (4) g4 CONT, SECTION SCALE: 1/2 " =1' -0" 1/2` METAL DECK - ® 18" O.C. 2L3x3x1/4 CLIPS, FIELD WELD TO EXIST. BEAM_ 10 BEAM - SEE PLAN BONG BEAMS W/ (11 g6 CONT.. @ 32" *079 EXISTING BEAM SEE PLAN TS5x5 COL. C. BEAM - SEE SECT. 7 ON SHEET S3 SECTION SCALE: 3/4"-1.-0- WIO BEAM - SEE-PLAN EXIST. CHANNEL - SEE PLAN 2L30x1/4 CLIPS. FIELD WELD TO EXIST. BEAM. SECTION N.T.S. EXISTING JOIST -OP NEW 8" CM, SEE ARCH FOR .„_4 ION. SECTION SCALE: 3/4"=1.-0" EXISTING JOIST CUT LINE VARIES (FIELD VERIFY) 4' -0 "0- FOR 8" JOISTS, SEE PLAN VARIES FOR 14" JOIST, SEE PLAN (FIELD VERIFY) tirdir MIN. 2" OF WELD (2) L 1/441 1/4x1/4" /2 /1 SHIM TOP CHORD 3 1 W \\ (2)Ll 1/2A 1/x6 x 4" LONG DASHED LINES REPRESENT PORTION OF J015T TO EBE 1/8 IN. 2" F WELD EXIST. TOP CHORD 2'xl/2' TYPICAL 1/8 I/O 0 4 1 /2 "O.C. EA. SIDE (2) L 1 I /2x1 1/2X3/16" EXISTING WI 8X40 CONT. 1/2 "X8" PLATE SECTION N.T.S. CO, . 1/4'X8" PLATE EXISTING W8X17 COLUMN SECTION N.T.S. DETAILS SHOWN ON THIS SHEET ARE APPLICABLE THROUGHOUT THE DESIGN =RAWNGS- THESE DETAILS ARE DEFINED AS GENERAL STANDARDS THAT RE USUAL NOT IDENTIFIED B, SPECIFIC REFERENCE WITHIN THE IR A WINGS. THESE DETAILS MA BE MODIFIED OR SUPERCEEDE^ C,FC OE TA -.A- ARE RE ERE, ED WITHIN THE DRAWNCS OENLARGED DETAIL N.T.S. 12X16 1/8 OR W8X15 REMOVED EXIST. 020P CHORD R 2 "xt 2" 21r TYPICAL 1 /8r 1/2" 0 4 1 /2 "0..EA. SI OENLARGED DETAIL,' N.T.S. JOIST MODIFICATION COPE BEAM TO ACCOMODATE CONNECTION (2) 3/4" DIA, BOLTS 3/16 (2)L3x3x1/4 x 6" LONG EXIST. 814, W16, OR 821. SEE PLAN SECTION N.T.S. Revisions Do Description 2 03 -10 -92 ISSUED FOR ADDENDUM "D" 3 03 -19 -92 ISSUED FOR ADDENDUM "E" Drawing References No SI S2 Drawings GENERAL NOTES FRAMING \ FOUNDATION PLAN ISSUED FOR BIDS: 01 -31 -92 ISSUED FOR PERMITS 02 -12 -92 CADD NAME: TP91502 PROJECT NO.: 262991 DRAWN BY: BTH CHECKED BY: PROTOTYPE DESIGNATION: 1991 REV. 3.91 THE WBDC GROUP 11.1 11111.1 11 1.1 II 11,1,11,1, N111,111.11,1; IN II Ill: 111k 50 MONROE PLACE GRAND RAPIDS TELEPHONE (616) 235 -6000 MICHIGAN 49503 FAX (616) 235 -6132 TOYS W VS National Office 461 From Road Paramus, NJ 07652 (201) 599 -7800 GEOFFREY This drawing is the Exclusive Property of TOYS "R" U5. The information shown may not be used nor the Drawings Reproduced without permission of TOYS "R" US. Location TU K WI LA, WA. Drawing Title TYPICAL DETAILS Scale AS NOTED Date 01 -31 -92 Sheet no. S3 I