Loading...
HomeMy WebLinkAboutPermit M95-0117 - BOEING #2-62; ...i.!.'',1....,1-...:'...: ' •':,.'••••."4,•,....;:t'.r '.., "" t3,". ,_ ....:: ... I' .---- ' r ..... t t .‘..„.• . , ■ : ' -; 1 ',.,_,) , . . , ,_ , , TI .3-1, 3 .:' • • . -) •' . . , :7;',.•;:;.:‘,/:c.).:-.:— • _..,.. ..::::j.:• ....'• . . 1•;:—..1.: ... \ 0 ---1, I.• _., <I. :• , ., ) .'.;•-.:Y'' t ■ r‘• :7; • ,•,y; • • . „ �i���a -rte City of Tukwila z (206) 431 -3670 Community Development / Public Works • 6300 Southcenter Boulevard, Suite 100 • Tukwila, Washington 98188 MECHANICAL PERMIT Permit No: M95 -0117 Type: B- MECHAN Category: NRES Address: 8123 EAST MARGINAL WY S Location: Parcel #: 000160 -0020 Contractor License No: TENANT BOEING #2 -62 8123 E MARGINAL WY S, TUKWILA, WA CONTACT LARRY ALLEN PO BOX 3707 M/S 19-15, SEATTLE WA OWNER BOEING PO BOX 3707 -:M/S 19 •15, SEATTLE, WA 98.124 ***********************-********************* ** * * * * * * * * * * * * * * * * * * * * ** * * * * * ** Status: ISSUED Issued: 08/15/1995 Expires: 02/11/1996 Suite: Phone: 544 -1644 Permit Description: INSTALL; AIR HANDLING UNIT PACE MODEL SCF- 63 :A /57A -MI HORSE POWER. 550 CFM. UMC Edition: 1994 SMALL CABITFAN 1. -1./2 Valuation: Total Permit Fee:".. 000.00 42.81 ************:*****'******* r*****.*** * * * *; *: * * * * * * * * * * * * * * * * * * * * * * ** *' * * * * * * * ** :o.. Perms,:' Center Authorized 'Signature ` 3- s - 9 Date I hereby; certify that I have read and.e:xamined this permit and Know the same to be true and correct. All provisions of law and ordinances governing this ',work will',be . complied with, whether specified herein or not The granting of - th'i.s permit does not ,presume to give authority :to, violate or cance.l`.the'provisions of any other state or l laws regulating construction or the performance of work. ;I am authorized to sign for and obtain this ":.building permit. Signature Print Name: ` �c T it 1 e -✓-1= k11 a-421P k‘ This permit shall bec'ome.nul l and, voi.d'.if-. the work:not commenced within 180 days from the date ;issuance, or if the:;wo'rkf'is suspended or abandoned for a period of ` 180: days:'rfrom: ;th'e, `l;ast inspection. CITY OF TUKWL4 Department of Community Development — Permit Center 6300 Southcenter Boulevard - #100, Tukwila, WA 98188 (206) 431 -3670 Mechanical Permit Application Tracking PLAN CHECK NUMBER 11195 -01 (1 P JECT NAME 160 el NCB — 2 - (72- SITE ADDRESS 6 12 3 FAST A O N R1- INrI 5 SUITE NO. INSTRUCTIONS TO STAFF • Contacts with applicants or requests for information should be summarized in writing by staff so that the status of the project may be ascertained at any time. • Plan corrections shall be completed and approved prior to sending to the next department. • Any conditions or requirements for the permit shall be noted in the Sierra system or summarized concisely in the form of a formal letter or memo, which will be attached to the permit. • Please fill out your section of the tracking chart completely. Where information requested is not applicable, so note by using "N /A ", date and initial. DEPARTMENTAL REVIEW "X" in box indicates which departments need to review the project. EPART.ME TE UILDING - initial review APPRO.V Z 5 9) OU ED UIREMENI !MM.EN' CONSULTANT: Date Sent - Date Approved O FIRE FIRE PROTECTION: Sprinklers Detectors N/A INIT: FIRE DEPT. LETTER DATED: INSPECTOR: O PLANNING ZONING: IBAR/LAND USE CONDITIONS? U Yes 0 No INIT: SCREENING REQUIRED ?. 0 Yes 0 No REFERENCE FILE NOS:: O OTHER INIT BUILDING - final review INIT: Ali 6 INIT: UILDING OFFICIAL Z5 REVIEW COMPLETED UMC EDITION (year): AMOUNT OWING: ��.$� CONTACTED u � RR ALA= v t si _ j ipi-I 1.11F 7- ntlasAA0 DATE NOTIFIE% 9 BY: 1 r 2nd NOTIFICATION BY: (init.) 3RD NOTIFICATION BY: (init.) 01/07/93 MECHANti SAL PERMIT APPLICATION CITY OF TUKWILA Department of Community Development - Building Division 6300 Southcenter Boulevard, Tukwila WA 98188 (206) 431 -3670 Mechanical Fee Worksheet must also be filled out and attached to this application. PLAN CHECK (NUMBER O APPLICATION MUST BE FILLED OUT COMPLETELY FEES (for staff use only) DESCRIPTION:..; AMOUNT RCPT::# BASIC PERMIT FEE UNIT(S) FEE PLAN CHECK FEE OTHER. • TOTAL SITE ADDRESS SUITE # VALUE OF CONSTRUCTJN - $ f PROJECT NAME/TENAN ,. w C.-�._. Q ASSESSOR ACCOUNT # �() /) /6 o- f) 4, .2 �� TYPE OF WOR O New /Addition KI Modlations [) Repair 0 Other: `A-) DESCRIBE WORK TO BE DONE: r� .TYPE RATING /SIZE< :::,, > :;;.: ; :.:::€ :.. ;:NUMBER:OF:UNITS : > e e.., : ! / :;:.::::%:.:::::.:.:::: -1 . - 4- 3 04 / 5 7 4 41 l S 1W ,.5. --(- ZIP SS0 If WA. ST. CONTRACTOR'S LICENSE # 2f2 E._T- / 9 y .0_, L EXP. DATE �^ 96 BUILDING USE (office, warehouse, etc.) 4:9 -64' W ` Ca -0.c r NATURE OF BUSINESS: v (f/ hie WILL THERE BE A CHANGE IN USE? J N 0 Yes IF YES, EXPLAIN: WILL THERE BE STORAGE OR USE OF FLAMMABLE, COMBUSTIBLE OR HAZARDOUS MATERIALS IN THE BUILDING? 0 No ® Yes IF YES, EXPLAIN: PROPERTY OWNER A ee -y,�, r ,/%l 'p PHONE ADDRESS �U / 3 7 1) 7 i� S l — /,5" / `A-) ZIP a « / r� CONTRACTOR r C, , ' PHONE ZIP ADDRESS __ - WA. ST. CONTRACTOR'S LICENSE # 2f2 E._T- / 9 y .0_, L EXP. DATE �^ 96 JHEREBY CERTIFY'THAT LHAVE READ,AND EXAMINED THISAPPLICATION A AND CORRECT.AND t AM'AUTHORIZED TO.APPLY:FOR THIS PERMIT. BUILDING OWNER SIGNATURE OR AUTHORIZED PRINT NAME ,e;1/7 / i< N AGENT ADDRESS C ONTACT PERSON SAME TO BETA DATE 7- 7 9.s PHONE �,/ 1i CITY/ZIP / PHONE- APPLICATION SUBMITTAL In order to ensure that your application is accepted for plan review, please make sure to fill out the application completely and follow the plan submittal checklist on the reverse side of this form. Application and plans must be complete in order to be accepted for plan review. BUILDING OWNER /AUTHORIZED AGENT If the applicant is other than the owner, registered architect/engineer, or contractor licensed by the State of Washington, a notarized letter from the property owner authorizing the agent to submit this permit application and obtain the permit will be required as part of this submittal. VALUATION OF CONSTRUCTION The valuation is for the work covered by this permit and must be filled in by the applicant. This figure is used for budget reporting purposes only and not to calculate your fees. EXPIRATION OF PLAN REVIEW Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may extend the time for action by the applicant for a period not exceeding 180 days upon written request by the applicant as defined in Section 304(d) of the Uniform Mechanical Code (current edition). No application shall be extended more than once. If you have any questions abgptegrayocess or plan submittal requirements, please contact the DepPIRIertff dUevitumunity Development at 431 -3670. DATE APPLICATION ACCEPTED 277 , t. 2 7 19')9ATE APPLIC44TIONEXPIRESqtp -PERMi i I lI 03/14164 SUBMITTAL CHECKLSST MECHANICAL Completed mechanical permit application (one for each structure or tenant) Two (2) sets of mechanical plans, which include: • Floor plan • System layout • Elevations (for roof mounted equipment) • Heat Loss Calculations Structural calculations stamped by a Washington State licensed engineer may be required if structural work is to be done (2 sets) Note: Hood and duct systems require a building permit for the duct shaft. Water heaters and vents are included in the UMC — please include any water heaters or vents being installed or replaced. ;;mss . .,,∎,% hi J t k..'7 +' 1 4*Ak•A *t A * *•k *A *k:t•! *A *A• •?•* * ** +A *****444A * * ***4• ** *k• *A *:kA * *•A•A CITY 11 Y1]L.A. WA � TRANSMIT k.a *Ah *;t�titk. *.k *fir :t * *'A % * *A* A *:S *:k :k* Akla: ** * *:t *A •+ 3• T Y O F• T I( • :4**k/.•k*** ***,t***** TRANSMIT Number: 94002742 Amount: 42.81 08/15/55 16:15 Payment Method: CHECK Notation: COMM. TRUST ACT. Znp6/1.5) P sP.ermit No: M95- -0117 Type:: 0-rMECHAN MECH(aNICAI.. PERMIT Parcel Na: 000160 -0020 Site Address: 8123 EAST MARGINAL WY S Total Fees: .42.81. .This Payment 42.81. Total ALL Pmts: 42.131 Balance: .00 *4* ** *•k *•4A*ft **4* *:Aft* *,•A•A ** *:flock *A• *A ***4 *A * * **** *•Ale* * *.•bk*.444•k * * *:t . Account •Cade Description Amount 000/345.830 PLAN CHECK - N0NRES 8.56 000/322.100 MECHANICAL NONRES 34.25 �4- 'FDC)6_._v(k 74,5tCo.:0:_cin/cersoiAci, ( 0 0 5s(p. fog , 3' t.. GENERA 8.56 GENERA 34.25 VOID GENERA -42.81 CASH 0.00 5300A000 . 16x24 INSPECTION RECORD Retain a copy with permit CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 PERMIT NO. (206) 431 -3670 Proje -6:7 _ Type of ins I n: ee,4 /-7. Address: Date called: Special instructions: Date wanted: Lf `9� p.m. Requester: Phone No.: Approved per applicable codes. �1__]_ Corjections required prior to approval. Inspector: Date:. .-2,..17f $42.00 REINSPECTIOM FEE REQUIRED. Prior to Inspection, fee must be paid at 6300 Southcenter Blvd„ Suite 100. Call to schedule reinspection. Receipt No.: Date: .��� .! INSPECTION RECORD Retain a copy with permit CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206) 431-3670 Project: cp, • , /1\1 .41 _ (6.2... r-, Type of Inspection: 1.--- r 1 f .,6i6,-r MAgfis4AL Idl 1- e el ^: . ' 1 — 22- - , - • • Instructions: S , . Date Wanted: A hiNi - 9(0 am. phi. Requester"1-6Fe 66M IR . . ft,Aks 0 Approved per applicable codes. ii.Lcorrections required prior to approval. COMMENTS: klAG, id -11,1 A?(X4 WO, . . ft,Aks GA L L. r.-(1 /L. t.,..../...Te-.1.JOid0 A il vt To -7-14 -047 otAA 6t. (7.-) 7-74 fli-, cz,v, 19 uci1 r4-- 1141 3 idt) 0 ft— fl- C.:1/ 1 S t.-7- et.,A,4 s. ..., • IInspector: L12.-31— I Dile: 1 7.3 `/ 0 $30.00 RBNSPECTION FEE REQUIRED. Prior to reinspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Ca to schedule reinspection. IReact No.: 1 Dile: • CITY OF TUIw.WILA Address: 8123 EAST MARGINAL WY .S Sulte:, Tenant: BOEING #2 -62 Status.: Type: B- MECHAN Applied: Parcel #: 000160 -0020 Issued: •k•*****•k•k'k ** k*** k* * *•k ** k•k*•k* k *'k k *•k * **•k*'k**'k k k k* k•k•k•k ** *•k* k*** k* k•k•k*** k'k Permit Conditions: 1. No changes wi 1 1 be madeii,n - approved by the Architect or Engineer'aia idyi: $:Division. 2 All permits, inspect :ori records, ands approve ;;C 1,s4 shall be avai 1ab'ie at the'! };:°ab siyyyt.�Jgp���it?rg tojtr �•. a start of"' ;6•r q con - ��/ i Y^ 4i L. •� ' /1L �. e f� (��' ,•�!R+R 3'R ~•4R struc.tion. T+i7, q?4ma.n�vt r are•.i1i;ito(Jk yG }t .maii�a n�aed an,11,0 rai 1- ab 1 e until �, # 1 triyLse,ct on'" approva 1 i!1a yr an e`d s ',,', 3. All c o n s t l.i,c<r ion t'o e done «i'n,l c o r "f o't- a n c e w•i t h' , p p r o')a,41 , plans andrrequir e,,me',, is of° the jUr lfor•m Bu11�d =inn r4 de (19' y1 Ed i t i or, ' 0'$ amended , W 'if orm`�• ,chap i ca 1 Code 'J(:,199.,) Edit i c i and Washing ton 'atatte'Eneriyk ,Code (1 :994 Edition r,, rk'4%. =ti , 4. Val i d f0t. o: fermi t•. Th •.,�tls' (3nce of 'a permit or �`,apprc va'1 p1an3 3pecificat1ons ,:;:and co`rnput,atIons shall not '.ble'rtsr-- strurd toi•b,e:ita perm it' "'f, r', oran°'..approva1 of, any viol :a.ti girl of a.n�v of the provisioils. -of,..�t�le bui..ld'ing code or of ,anv AA 41 "r �" ", �No . er•mi t r•esumi�:n ''to oth�r� ori.inan�.e of bhe''�-iur�isd�i�tiont.::: p p give' authority to..'jiol'ate"`.+ riica'n9el the)provisions ofd, this co •e' "!shall :be "va 1 a,d . •,....�, �\ j�,1j ,, .i''•:.`„it, fi . 5. f TALLAT,ICIN' IN'� TRUCTI0N t REOU ` ' �. MA �1�FAC.ETCIRER;, ��IN� t .� r .�., FOR`': THE WILDING (INSPECTORS -REVIEW .',t , j 6. Ele,c'ttr1 a,1 :perrmits,`,stha11. be obta•ine�d�. through the Wash <ington -� z Sta'te,tDivis3on� of Labor,; ands Indu,'s,tr, ies, and'- •a,.l,1 electr�i cif '',4f; work' ;wi V1 `be inspected by that agency (24'8- '66.3,0) . 0, } Permit No: M95 -0117 ISSUED 07/27/1995 08/15/1995 k*** k* SEIWO•s am r �a.y3'4. i L7 t- ti s ER 5�. P ttw�ts 1`3Conipl•ts It� Nl' 4 i -° � .Compete 1 ems 3, and, 4 ,t1(71 :k., i,,�s // rft .Prinj yoifr name end`s dA 'ai J, ri the, r' , t e. veyd oJ�h,, for f so etUrh this ard to your `f �'. lti'.p° f ',1:P4. • Attech thia form to t o the mllace or the c beck ia 1?f � sr v pd/as, c, eera tr a dwj ros� " eS i e;a s dosio,(t ; i .X'A s" neINai i� n it yr;r,� r4 PA r d, k Wr�eiiZkieturn Rteelpt ftegtiested',. on the rneilplaea bow the artlole tim er U Reetilnted :Deli V ; a edN % y Tho Rettim Re crpt 7II •how to wom the arifcia Yaa dellwred and the difii s V(t.;r t ,'3:r "I{ m'r '� l teredAi A,I A, . 6 ,i'r",l' 3' rr t i 7 i'+;'�J {(t ,,I, , {ra,21,, ii iklafeg., Z oneulf'postmastel ; sfor.fee 3� Article;.A'ddreaeed"td:}} °rfr�x { s' T 4eS{+` 'rt gle; ti be �t. t: va «- 4f + ti i js1t .rd ? rt e{ 3xc,:1 N i11 pp � � r nA yT ,�y {yVrll'� i, � .,�7 4 S �, S-.'�• q c �)�` `~Y h` /�,q/ N, 1Z�1. }.^:.. .•{,. .)�.♦•.jrt} By� /j�/Syp r {c /ryt/JJr�..�fl.�tl �i._"„�.ro /.Yr r � �� �{/ .t r' /V'�I• P 112 198 126 Receipt for Certified Mail . No Insurance Coverage Provided w., osurrs Do not. use for International Mail •ofr rxwCr (See Reverse) S nt r i '� / �/) J� r , ,.,� �/ 9 • .1 11,4. ",11,/ ., 1 Postage ) t3 ? Certified rue /. /U Special Delivery Fee Restricted Delivery Foe Return Receipt Showing .to Wham & Data Delivered /, /O Return Receipt Showing to Whom, Date, and Addressee's Address Postage. k. JS Postmark eialev i / /241 City of Tukwila ` -'FILE DOPY John W Rants, Mayor Department of Community Development Steve Lancaster, Director January 27, 1997 Larry Allen The Boeing Company P.O. Box 3707 M/S 19 -15 Seattle WA. 98124 Dear Permit Holder : On June 13, 1996 you were notified your permit number M95 -0117 would expire on July 21, 1996. Since June 13, 1996 our records indicate that no inspection or extension requests were made. Due to the expiration of your permit, as of January 27, 1997 this permit is now closed without the benefit of a final inspection. Any further work on the project will require a new permit application submittal and additional fees. Any new submittal will require compliance with the current edition of the Uniform Building Code. If your project has been completed please contact the permit center for proper closure procedures A final inspection and approval will be required. If you have any questions or need further assistance please contact Kelcie Peterson at the City of Tukwila Permit Center at (206) 431 -3672 Sincerely, 706te-16:dte.5e12 Kelcie Peterson Permit Coordinator Sent Certified mail #P 112 198 126 6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • (206) 431-3670 • Fax (206) 431-3665 City of Tukwila FILE COPY John W. Rants, Mayor Jun 13, 1996 Department of Community Development Steve Lancaster, Director LARRY ALLEN PO BOX 3707 M/S 19 -15 SEATTLE, WA RE: BOEING #2 -62 Dear Permit Holder: Our records indicate that on Jul 21, 1996 one hundred and eighty days will have passed with no inspections having been called for under Tukwila Mechanical Permit Number M95 -0117. Unless you call for an inspection, or obtain a written extension from the Tukwila Building Official prior to that date, your above referenced permit will become null and void on Jul 21, 1996. If your project is complete please call for final inspection. If you are actively working on your project please contact our office. If you have any questions or need further information to obtain an extension on your permit please call the Tukwila Building Divison at 431 -3670. Sincerely, y� k1 ./ Kelcie J. Peterson Permit Coordinator Department of Community Development 6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • (206) 41313670 • Fax: (206) 4131.3665 j" DETACH TO DISPLAY CERTIFICATE-1 MM63Y ✓_4.k016N�/ _ri rY✓NN3N✓rry �v }y �Y feYY�IM✓.��3d3yJ�Y./+W!..r~2W..ddi et~eP✓_+Sf ;e�!L�A�k' YC!;..;Ittrr% �. � �T_i }}7•liOil`"��� . 1'tA4? %'^•' 4 ♦.', ti;V•�.{; �•'�t7y,i i•.y. J� .Iaa f v'f� y.;..`_._ �.c �' J:r t'{{SYKY'�•4����' �,, + !t.,►ls��,y,ry�i,:Ty(t+if �.�{,'.�,�'i; �`IY�Q`" ��`�C+. r` i`�;lt Ni >S��f• �1����77�r�lYH4F'�]�'..11S•�i). �� ?.�7ii_.i•� 11. '4. Ta`,vr r r, -r ��i4 ��M, f^.�%y�•FyiJi;���ra'K�a�;i::2 !' S2 �n .I�f / ati;a ;1r�'•;•CQfigA iti'fi4.Tit -.. "i °: • 4y P;;r '01'.. 30X ?f,, . 3 70 1 .'''''.4! a .r, .• .fie}.'.. • .Mis'IL > :..1%,i1OF':w: FM0-9: . StrATr:LE. : :N!A;' :?93124i' 22.0' . . • L. DETACH TO DISPLAY CERTIFICATE._1' PLANT 2 IAL BUILDI SH WATERWAY E. GATE 0 -18 SITE ACCESS PROJECT AREA 2 -84 2 -117 2 -116 VICINITY MAP 05--0111 BUILDING CODE NOTES OCCUPANCY SEISMIC ZONE B-2, OFFICE AND LIGHT MANUFACTURING 3 PROJECT AREA 768 SF OUTSIDE SHEET NO MECHANICAL 2.62 -1M10 LEGAL DESCRIPTION APN: 000160 -0020, A TR/rCT OF LAND BETWEEN THE DUWAMISH WATERWAY AS ESTABLISHED BY COMMERCIAL WATERWAY DISTRICT # 1 OF KING COUNTY, WASHINGTON & E. MARGINAL WAY, IN SECTIONS 28, 29, 32 & 33, TOWNSHIP 24 N, RANGE 4 EAST, W.M., DESCRIBED IN: KROLL 8001; PAGE 79. TRACT CONTAINS AN AREA OF APPROX 2,897 955 SQ FEET. SITE ADDRESS: 7755 EAST" MARGINAL WAY SOUTH DRAW14C INDEX 2I1LE REVISION DUCTWORK 2.62 —M505 SECTIONS AND DETAILS A,B A FILE COPY :nderstand Ihal the Plan Check approvals are !;;I;,c I to error, and omissions and approval of does n,-,t the violation of any ;.,;opted caiu or ord,n;.nre Receipt of con- ,.;ctor's copy of apl!roveo flans acknowledged. PERMIT SEP RED FOR. (] MECHANICAL ;',ELECTRICAL 0 PLUMBING GPS PIPING OF TUICWUA CO OF DIVISION �NCU 5 N1G �. RECIV'cD CITV OF TUKWIIA PERMIT CENTER REVISION BY APPROVED DATE SYM REVIS +ON BY APPROVED DATE FACILITIES DEPARTMENT ❑ AUBURN, WA. 98002 ❑ EVERETT, WA. 98201 D KENT, WA. 98031 D PORTLAND, OR. 97220 ❑ RENTON, WA. 98055 ® SEATTLE, WA. 98124 ACCEPTABILITY THIS DESIGN AND /OR SPECIFICATION IS APPROVED DRAWN BY N. HUTTO CHECKED 8/115/91 SABIITLE COVER SHEET 2.62 LAST REVISION ISYM DATE APPROVED BY DEPT. JATE -ENGINEERED BY R.FEDERSPIEL CHECKED 9/11/91 APPROVED TITLE ARCH I TECTI.)RAL MASTER SHEET Al JOB NO 210013-00 OF AUTOCAD 2, 3 ) ( /1 ) 8) PLAN VIEW GIS-4)10 SCALE: g= 1' -0" Jpi CONSTRUCTION NOTES INSTALL NEW AIR HANDLING UNIT AHU -1H1. SEE SECTION A, SHEET M505. INSTALL NEW DUCTWORK AS SHOWN. ALL WORK AND MATERIALS ARDS. SHALL CONFORM TO SMACNA AND BOEING STAND INSTALL NEW SUPPLY DIFFUSERS AS SHOWN. (TYP -4) BALANCE SUPPLY AIR SYSTEM TO AIRFLOWS SHOWN. 1 RELIEF /BACKDRAFT DAMPER AND XTERIOR WAL OUVER AS SHOWN. INSTALL AT APPROX 5' -6" A:IV ISHED FLOOR. INSTALL 0 -0.5" DIFFERENTIAL PRESSURE GAUGE. HIGH PRESSURE CONNECTION TO REMAIN IN CHANGE ROOM. LOW PRESSURE CONNECTION TO BE ROUTED THROUGH WALL INTO SAND BLAST AREA. SEAL WALL PENETRATION TO ELIMINATE PASSAGE OF AIR. GENERAL NOTE L1_> INTERL •.• FAN MOTOR WI ROOM LIGHTS. REFERENCE DRAWINGS M1 EQUIPMENT SCHEDULES M1M10 MEZZANINE FLOOR PLAN M310 HVAC CONTROLS M505 HVAC SECTIONS AND DETAILS P' \‘,0.0\\16\0c,\ NC 0\\16 \0c,\ M12 KEY PLAN SCALE: NONE REVISION FILTERS & CHANGE ROOM J #450044 ADD DIFF PRESS GAUGE J #450044 BY GAVRAS GAVRAS APPROVED WSJ DATE 6/19/9 SYM REVISION BY APPROVED DATE FACILITIES DEPARTMENT ❑ AUBURN, WA. 98002 ❑ EVERETT, WA. 98201 ❑ KENT, WA. 98031 ❑ PORTLAND, OR. 97220 ❑ RENTON, WA. 98055 SEATTLE, WA. 98124 ACCEPTABILITY THIS DESIGN AND /OR SPECIFICATION IS APPROVED DRAWN BY SLOAN CHECKED R .GLADNEY DATC 10/26/90 12/17/90 SUBTITLE FLOOR PLAN J #450044 LAST REVISION RECEIVED CITY OF TUI�! ^��! F PERMIT CENTER B 7/12/95 SYM DATE APPROVED BY DEPT. )ATE 'ENGINEERED BY W. BUCKLEN CHECKED APPROVED 10 / <:i 90 11/2/90 APPROVED TITL MECHANICAL MASTER PIN; 2 52 -1 fill A- .I/1 -11 SHEET -10 OF JOB NO. 009012 DB/287 DWG. N0, PIT 7 2.62 -1M10 _ T T / J T 1 11 tLJ I T I� 1 1 Q 1 �'- I ^ 1rnrn J ff1 1 X33 W1QX33 :'d1OX I 4X33 - 13X6 t - -- 8"I - __ \ / , 1' UP TO W1QX33 W1QX33 EXHAUST FAN 15X25 W1QX33 W1QX33 W1QX33 1------1 5X13 13X6 8X17 I ii_ - /---- II- -_ / \ � g "I / \ S -350 12X12 REGISTER } I I I I I I ? I PI h. A IT I Na. 41■41 CFM - r- II 14X24 11. - I l I I n r ( 1 N \/ r--� � \ 14X8' 10 °I 1 i I FI �II'I' I I " I II II I I II lIaI 1- . 11 13X20 VOLUME DA JAPER REGISTER E -600 CFM (TYP. FOR 3) 101 14X8 \ / r 11 % \ -\"- S -600 CFM 13X21 - :d II II ILIIII btl t>S L li , - - - -_J 1 X VOLUME DAMPER 8X14 11 ,-14X8 10 "1 / I _ - FOR FILTER - 0 BOX, SEE DETAIL 1 M10 1M501 12X19 / VOLUME DAMPER 1 . (.-� / S-600 1� 150 14X6 - 0 6X14 ! - MT -n .'� 71X11 RILL: _,,,_,I 74X: �f 1 8X18 A SD-2 SD -2 CFM s'DIA \o}-8 1 _ S 40c CFI _U1 6X8 0 M505 150 CFM 150 ° AHU � @:. <a 1H1 15 $ © �, g11�M1mat 1 J!u,, %II. 6"DI,1 RD -1 80 CFM SD 1 100 CFM sD -2 .0 . 150 CFM DIA a 411111ftl � 7' HIGH •'ARTITION 8X6 E-151 TCFM (TYP. FOR 2) — — — 4 ,, C _ _ — ._ ,� -- o DP d PLAN VIEW GIS-4)10 SCALE: g= 1' -0" Jpi CONSTRUCTION NOTES INSTALL NEW AIR HANDLING UNIT AHU -1H1. SEE SECTION A, SHEET M505. INSTALL NEW DUCTWORK AS SHOWN. ALL WORK AND MATERIALS ARDS. SHALL CONFORM TO SMACNA AND BOEING STAND INSTALL NEW SUPPLY DIFFUSERS AS SHOWN. (TYP -4) BALANCE SUPPLY AIR SYSTEM TO AIRFLOWS SHOWN. 1 RELIEF /BACKDRAFT DAMPER AND XTERIOR WAL OUVER AS SHOWN. INSTALL AT APPROX 5' -6" A:IV ISHED FLOOR. INSTALL 0 -0.5" DIFFERENTIAL PRESSURE GAUGE. HIGH PRESSURE CONNECTION TO REMAIN IN CHANGE ROOM. LOW PRESSURE CONNECTION TO BE ROUTED THROUGH WALL INTO SAND BLAST AREA. SEAL WALL PENETRATION TO ELIMINATE PASSAGE OF AIR. GENERAL NOTE L1_> INTERL •.• FAN MOTOR WI ROOM LIGHTS. REFERENCE DRAWINGS M1 EQUIPMENT SCHEDULES M1M10 MEZZANINE FLOOR PLAN M310 HVAC CONTROLS M505 HVAC SECTIONS AND DETAILS P' \‘,0.0\\16\0c,\ NC 0\\16 \0c,\ M12 KEY PLAN SCALE: NONE REVISION FILTERS & CHANGE ROOM J #450044 ADD DIFF PRESS GAUGE J #450044 BY GAVRAS GAVRAS APPROVED WSJ DATE 6/19/9 SYM REVISION BY APPROVED DATE FACILITIES DEPARTMENT ❑ AUBURN, WA. 98002 ❑ EVERETT, WA. 98201 ❑ KENT, WA. 98031 ❑ PORTLAND, OR. 97220 ❑ RENTON, WA. 98055 SEATTLE, WA. 98124 ACCEPTABILITY THIS DESIGN AND /OR SPECIFICATION IS APPROVED DRAWN BY SLOAN CHECKED R .GLADNEY DATC 10/26/90 12/17/90 SUBTITLE FLOOR PLAN J #450044 LAST REVISION RECEIVED CITY OF TUI�! ^��! F PERMIT CENTER B 7/12/95 SYM DATE APPROVED BY DEPT. )ATE 'ENGINEERED BY W. BUCKLEN CHECKED APPROVED 10 / <:i 90 11/2/90 APPROVED TITL MECHANICAL MASTER PIN; 2 52 -1 fill A- .I/1 -11 SHEET -10 OF JOB NO. 009012 DB/287 DWG. N0, PIT 7 2.62 -1M10 EXTERIOR WALL FUTURE HEATING COIL TRANSITION - 12'DIA INLET GRILL EXTERIOR WALL LOWER 9°Jt5' MOUNTING CLIPS (TYP 4) SECTION SCALE: 1/2'' = 1' -- CHANGE ROOM ROOF 6' X 6' WOOD SLEEPERS (TYP 2) 8' X 8' COUNTERBALANCED RELIEF DAMPER (A� 1M10,11905 DETAIL - ELEVATION VIEW SCALE: NONE 1M10 M505 FILTER HOUSING WITH 1° INSODE FLANGE DETAIL SCALE: NONE TRANSITION WITH 1° OUTSIDE FLANGE 1/4' THICK NEOPRENE GASKET MqS-0117 M( M505 1/4' NEOPRENE GASKETING TRANSITION DUCT NEW FRAME 14 GAUGE SHEET METAL CUALKING /SEALANT ALL AROUND FRAME DETAIL SCALE NONE EXISTING DUCT THROUGH WALL M504 M505 WALL CONSTRUCTION NOTES INSTALL NEW CABINET FAN PER MANUFACTURER'S INSTRUCTIONS. INSTALL NEW DIFFERENTIAL PRESSURE GAUGE AND ASSOCIATED TUBING. FABRICATE AND INSTALL 8" X 8" DUCT THROUGH INTERIOR AND EXTERIOR WALLS. PROVIDE FRAMING AROUND DUCT AS REQUIRED. . INSTALL NEW RELIEF DAMPER. ADJUST COUNTERBALANCE AFTER FAN STARTUP TO ENSURE PROPER OPERATION. 6 INSTALL EXTERIOR WALL LOUVER, PROVIDE CAULKING, SEALANT AND FLASHING AS REQUIRED. FIELD VERIFY ALL DIMENSIONS AS REQUIRED. PER,AT CENTER REVISION BY APPROVED DATE SYM REVISION APPROVED DATE CHANGE ROOM J #450044 -00 GAVRAS WSJ 7/25/95 ® ®E //VG FACILITIES DEPARTMENT ACCEPTABILITY THIS DESIGN AND /0R SPECIFICATION IS APPROVED APPROVED BY DEPT. DATE DRAWN BY S. GAVRAS CHECKED ENGR. S. GAVRAS CHECKED APPROVED APPROVED 6/5/95 SUBTITLE HAVC SECTIONS AND DETAILS BOL LAST REVISION DATE 6/5/95 TITLE BUILDING 2.62 MECHANICAL MASTER COL PLT 2 SHEET M 5 0 5 OF JOB N0. 450044 -00 MP N0. 8137 N0. M2.62 -M505