HomeMy WebLinkAboutPermit M95-0121 - TRADESHOWQ cr
IT<P4141-DI
pnSO1l
City of Tukwila ( 431 -3670
Community Development / Public Works • 6300 Southcenter Boulevard, Suite 100 • Tukwila, Washington 98188
MECHANICAL PERMIT
Permit No: M95 -0121
Type: B- MECHAN
Category: NRES
Address: 11621 EAST MARGINAL WY S
Location:
Parcel #: 102304 -9044
Contractor License No:
Status: ISSUED
Issued: 08/23/1995
Expires: 02/19/1996
Suite:
TENANT TRADESHOW
11621 E MARGINAL WY S, TUKWILA, WA 98168
OWNER BEDFORD PROPERTIES INC
12720 - GATEWAY DR., SUITE 107, SEATTLE WA 98168
CONTRACTOR PARSLEY ENGINEERING, INC. Phone: 836 -2926
4620 232 AV. NE, REDMOND, WA 98053
CONTACT RONN PARSLEY .
4620 232 AV NE, REDMOND, WA 98053
************************************* * * *** * * *'k•k * * * * ** * ** * * * * * * * ** k * * * * * * ***
Permit Description:
Phone: 836 -2926
INSTALL'3 NEW�,..ROOFTOP GAS /ELEC'j.PACKAGED UNITS
TOTALLING 14 TONS.WITH DUCTWORK. PROVIDE AND
INSTALL 4 EXHAUST FANS:.FORRESTROOMS.
ROOFTOP, GAS /ELEC AIR.:.CONDITIONING UNITS
24`° TON /4 TON /6 TON j3 UNITS' TOTAL)
CEILING EXHAUST FAN, 100CFM/100CFM /200CFM /300CFM
:(4 EXHAUST FANS TOTAL)
UMC Edition: 1994
Valuation:
Total Permit Fee:
12, 000.00
89.69
*************.****************************** * * * * * * * * * * * ** * * * * * ** * * * * * * * * * **
Permi Center Authorized Signature Date
z3- 9 s
I hereby certify that I have read and examined this permit and know the
same to be true and correct. All provisions of law and ordinances
governing this work will be complied with, whether specified herein or not.
The granting of. this permit does not presume to give authority to violate
or cancel the'provisions of any other state or local laws. regulating
construction or the performance.of.work., I am authorized to sign for and
obtain this building:perrnit.
Signature:_
Print Name:__ j6L,5/p
/ _J_L_6L
Date:
Title: f41.E.jk1s1D.��2r.-
This permit shall become null and void if the work is not commenced within
180 days from the date of issuance, or if the work is suspended or
abandoned for a period of 180 days from the last inspection.
CITY OF T(!KW!(
Department of Community Development — Permit Center
6300 Southcenter Boulevard #100, Tukwila, WA 98188
(206) 431 -3670
Mechanical Permit Application Tracking
PLAN CHECK
/NUMBER
/�
1 i r V `l1
PROJECT NAME
CONTACTED RO� r�l
KN\ C\I 17(\%L el (I1/sii')
SITE ADDRESS
11 � E- IVN.!� -1 I RN-
W.
s
SUITE NO.
INSTRUCTIONS TO STAFF
• Contacts with applicants or requests for information should be summarized in writing by staff so
that the status of the project may be ascertained at any time.
• Plan corrections shall be completed and approved prior to sending to the next department.
• Any conditions or requirements for the permit shall be noted in the Sierra system or summarized
concisely in the form of a formal letter or memo, which will be attached to the permit.
• Please fill out your section of the tracking chart completely. Where information requested is not
applicable, so note by using "N /A ", date and initial.
DEPARTMENTAL REVIEW
"X" in box indicates which departments need to review the project.
DEPARTMENT : DATE IN APPROVE
f� icy
initial review (ROUTED)
9BUILDING -
CONSULTANT:
Date Sent
Date Approved -
FIRE � inlyj r(�k �3'
l INIT) i a
O PLANNING
INIT:
FIRE PROTECTION:
L)Sprinklers Detectors L)N /A
FIRE DEPT. LETTER DATED: R- /,i yrg,— INSPECTORS #L—AD
ZONING: BAR/LAND USE CONDITIONS? 0 Yes 0 No
SCREENING REQUIRED? 0 Yes 0 No
REFERENCE FILE NOS.:
O OTHER
cwBUILDING -
final review
:UILDING ���
OFFICIAL
INIT:
INIT:
INIT:
UMC EDITION (year):
5h
REVIEW COMPLETED
OWIN F'f
iv „
i
Al C9 (O
A
CONTACTED RO� r�l
KN\ C\I 17(\%L el (I1/sii')
DATE NOTIFIED
BY:
- 23- qi---) (init.)
c.....
2nd NOTIFICATION
BY:
init.
()
3RD NOTIFICATION
BY:
(init.)
01/07/93
MECHANi AL PERMIT
APPLICATION
CITY OF TUKWILA
Department of Community Development - Building Division
6300 Southcenter Boulevard, Tukwila WA 98188
(206) 431 -3670
PLAN CHECK
NUMBER M� ,J 2• l
APPLICATION MUST BE FILLED OUT COMPLETELY
FEES (for staff use only)
DESCRIPTION .: :
AMOUNT ;
RCPT #
: >'::: DATE;;.:::
BASIC PERMIT FEE
x$15.00
. . :TYPE :;.RATING /SIZE: ...::::` .:. ; . :.:::NUMBER OF:. UNITS:;€ ::; >: :.;;: _:;::: >:
,.COFfOP, bas /4-•4 CT21C r4 /2COND/fOrtl /4lG O// /TS 4 oN /4i'N /r$t N 3 UN/ r5 • ToTA4.
UNIT(S) FEE
PLAN CHECK FEE
�A
ADDRESS /4 2 O 3�.
OTHER:
NATURE OF BUSINESS:
WILL THERE BE A CHANGE IN USE? 0 No 0 Yes IF YES, EXPLAIN:
WILL THERE BE STORAGE OR USE OF FLAMMABLE, COMBUSTIBLE OR HAZARDOUS MATERIALS IN THE BUILDING?
N No 0 Yes
IF YES, EXPLAIN:
TOTAL -
SITE ADDRESS SUITE #
(162.I E MARGINAL WAY SouT*l
VALUE OF CONSTRUCTIQN - $
/2, ODO,
PROJECT NAME/TENANT
TR,A ESR-oW
ASSESSOR ACCOUNT #
102.304 -'1644
TYPE OF WORK: g New /Addition [] Modifications 0 Repair 0 Other:
DESCRIBE WORK TO BE DONE: INST4LL 3 NEW Rao F1-0P , GAS /E I- ECt2lL PACKAGED ON 1 -S
Tot—ALL.tt.IG 14 To NS wtTlr4- Duct-woebc.PRoYtDE AND LUST-ALL 4 Ex -Rest FANS Fog RESTRooV
. . :TYPE :;.RATING /SIZE: ...::::` .:. ; . :.:::NUMBER OF:. UNITS:;€ ::; >: :.;;: _:;::: >:
,.COFfOP, bas /4-•4 CT21C r4 /2COND/fOrtl /4lG O// /TS 4 oN /4i'N /r$t N 3 UN/ r5 • ToTA4.
CC /L //YG EA/Fi4U. T g A N t o o c - F r Y , / / o o th /too ai i /Alo
c{-ry, 4 6X4%4 USf- FAAIS
�A
ADDRESS /4 2 O 3�.
BUILDING USE (office, warehouse, etc.)
OFFICE .4 WAREFIDu.SF
NATURE OF BUSINESS:
WILL THERE BE A CHANGE IN USE? 0 No 0 Yes IF YES, EXPLAIN:
WILL THERE BE STORAGE OR USE OF FLAMMABLE, COMBUSTIBLE OR HAZARDOUS MATERIALS IN THE BUILDING?
N No 0 Yes
IF YES, EXPLAIN:
PROPERTY OWNER CH A T/t -Ii.
M
C[, ,
) °1 .1
7'7
s e ,a- -rT- /e
PHONE
PHONE R3
EXP. DATE
ZIP 9Y / / q1
C — 2-7 a-6
ZIP S z-
ADDRESS 0 /3 D -%<
CONTRACTOR
�A
ADDRESS /4 2 O 3�.
•-+� •r'
v e
Ate. /,
WA. ST. CONTRACTOR'S LICENSE #
.I:HEREBY: CERTIFY THAT I HAVE;READ.AND EXAMINED THIS APPLICATION: AND KNOW THE SAME.TO BE TR
.:AND•CORRECT, AND:I AM: AUTHORIZED: TO APPLY:FOR THIS:PERMIT '
DATE
BUILDING OWNER SIGNATURE
OR
AUTHORIZED
AGENT
PRINT NAME
ADDRESS O
•
/
2_ eve Oy €
CONTACT PERSON
PHONES.3 - 9��
CITY/ZIP 9,ro 3
PHONE
APPLICATION SUBMITTAL In order to ensure that your application is accepted for plan review, please make sure to fill out the
application completely and follow the plan submittal checklist on the reverse side of this form. Application and plans
must be complete in order to be accepted for plan review.
BUILDING OWNER /AUTHORIZED AGENT If the applicant is other than the owner, registered architect/engineer, or contractor licensed
by the State of Washington, a notarized letter from the property owner authorizing the agent to submit this permit
application and obtain the permit will be required as part of this submittal.
VALUATION OF CONSTRUCTION The valuation is for the work covered by this permit and must be filled in by the applicant. This
figure is used for budget reporting purposes only and not to calculate your fees.
EXPIRATION OF PLAN REVIEW Applications for which no permit is issued within 180 days following the date of application shall
expire by limitation. The Building Official may extend the time for action by the applicant for a period not exceeding 180
days upon written request by the applicant as defined in Section 304(d) of the Uniform Mechanical Code (current
edition). No application shall be extended more than once.
If you have any questions about our process or plan submittal requirements,
please contact the Department tea✓ pAynunity Development at 431 -3670.
CITY OF T 11fw1
AUG DATE APPLICATION EXPIRES
1995
PERMIT CENTEV
DATE APPLICATION ACCEPTED
rZ 1�
03/14/04
SUBMITTAL CHECKLIST
MECHANICAL
I---Completed mechanical permit application (one for each structure or tenant)
Two (2) sets of mechanical plans, which include:
'Floor plan
X System layout
• Elevations (for roof mounted equipment)
✓Heat Loss Calculations.
Structural calculations stamped by a Washington State licensed engineer may be
required if structural work is to be done (2 sets)
Note: Hood and duct systems require a building permit for the duct shaft.
Water heaters and vents are included in the UMC — please include any water heaters or
vents being installed or replaced.
( INSPECTION RECORD
Retain a copy with permit
CITY OF TUKWILA BUILDING DIVISION
6300 Southcenter Blvd., #100, TukwilaMA .98188
mc16
0
(206) 431-3670
•roe..
'C$• 0 AO—
ype o ns .
Ion:
III• -, -Q - -
. , , ress:
$:e ern
LI
*- - C6
1
0 ■ .w.r OAII
Sp - Instruct ons:
i . (X) Nn.
3\w. Koht.e y
Date Wanted:
t _ _
t 5 am, p.m.
Requester:
Phone No.:
Approved per applicable codes.
0 Corrections required prior to approval.
COMMENTS:
Inspector:
DO: 5/1
o $30.00 REINSPECTION FEE REQUIRED. Prior to reinspection, fee must be paid at
6300 Southcenter Blvd., Suite 100. CaN to schedule reinspection.
Rectil No.:
'
INSPECTION RECORD
Retain a copy with permit
CITY OF TUKWILA BUILDING DIVISION
6300 Southcenter Blvd., #100, Tukwila, WA 98188
(206) 431 -3670
i�rojed� . �.— �E�j �- ,Od�i '
Type of inspect
Kg. S O:c:. �k
Addi��: 21
" AilAr�,►AI�L-
Date Called: � � _� _ C�c�
• • Instn�ctions: y�frI Cj
�- i,1�� -Di�Pi:.., i fJ P_
3 PM
Dale wanted: 1'
,
� — �� aen.r
Requester:
Phone No.:
7 —
(6,
❑ Approved per applicable codes.
Corrections required prior to approval.
COMMENTS:
) 615,47 -gA- G r k V . _ / 1,1 S i ` A • c . l . � ' � S i w t t r O "t ro /L.. -.
C) .-) TV% •1 2.r'- -71". g-•r-) Si 0 6—/ 5 tJ Sr‘--r or 'T'bl S
Sv,PP1 nor �/
wrc.c -4, �N "Ixi criv.'7+ -)
r
to 014 '114; / 9 414 . Uri c. .
2 -) t •ro 6-b .. te) I4 U C.tc • A. .-(1%.,‘ ft..
s- - ° "- -
1
44 era A •1Y wA N .
•
❑ $30.00 REINFECTION FEE REQUIRED. Prior to reinspection, fee must be paid at
6300 Southcenter Blvd., Suite 100. Call to schedule reinspection.
React iV3.:
Date:
1
INSPECTION RECORD
Retain a copy with permit
CITY OF TUKWILA BUILDING DIVISION
6300 Southcenter Blvd., #100, Tukwila, WA 98188
MIS
0/24
PERMIT NO!
(206) 431-3670
397 d1
- Type of In on: /-
214e f
2,-- ( ..--. 'el / 64/
Address:B(024 ./-:::: Ail
Date Called:
- ---72-, 44.../t/t,°-,--1-70--4-P, .. .
Special Instructions:
Date Wanted: //... 6 46-
am
Requester:
5) F:77>,1 P-;>--1 k411-14,94(
Mono No.:
-7? -1-/- /-4,/
0 Approved per applicable codes. S. Corrections required prior to approval.
, It
COMMENTS: i) 7:,..,-4.7., ii,./ e> t,,, /ei., 'till i eie 47
fkr.9.,, A - zili----
2,-- ( ..--. 'el / 64/
sCrs ,r,ri /72 4-Jr— Ljil-a ef 4/ ‘5e_ii-0,}e--- e.ei /(
ii'/- /LL ztadie., /rise._
- ---72-, 44.../t/t,°-,--1-70--4-P, .. .
il):1;1 h1 / 1 / 14ei-Li
, -- -, ..,..._ 2 is
,...-
et-,..,/ /--
5) F:77>,1 P-;>--1 k411-14,94(
.0-1 - iii (1
-7? -1-/- /-4,/
/..4.,,,./- )2-, 41- A-Aim vz-
44. -
4
0 $30.00 REINSPE FEE REQUIRED. Prior to reinspection, fee must be paid at
6300 Southcenter Blvd., Suite 100. Ca to schedule reinspection.
IReceipt No.:
1
INSPECTION RECORD 0
Retain a copy w/th permit
CITY OF TUKWILA BUILDING DIVISION
6300 Southcenter Blvd., #100, Tukwila, WA 98188
(206) 431 -3670
• ro TGCJ D�
ype o ns, :. , n;11
i �U
Address:
Date Called:
Special Instructions:
Date Wanted:
I 04 A S
am. p n.
Requester.
Plane No.: V1/43- 033 (c5
XApproved per applicable codes.
❑ Corrections required prior to approval.
COMMENTS:
Inspector:
—ISete: fin 719_4s
❑ $30.00 REINSPECTION FEE REQUIRED. Prior to reinspection, fee must be paid at:
6300 Southcenter Blvd., Suite 100. Cali to schedule reinspecUon.
IRecepi No.:
JDale:
•
City of Tukwila
Fire Department
John W. Rants, Mayor
TUKWILA FIRE DEPARTMENT
FINAL APPROVAL FORM
Project Name -//2/) be - - /ice
Address
Thomas P. Keefe, Fire Chief
Permit No. ,40/6' 60-
/ %�(,,, / 6, v104116, • Liz . .
//// Retain current inspection schedule
H.
Needs shift inspection
Suite #
Approved without correction notice
Approved with correction notice issued
Sprinklers:
Fire Alarm:
Hood & Duct:
Halon:
Monitor:
Pre -Fire:
Permits:
1\451.2 c".4-5,14-14-1
Authorized Signature
FINALAPP.FRM
: 0 -,/2. h1/4C1 ClC
Date
T.F.D. Form F.P. 85
Headquarters Station: 444 Andover Park East • Tukwila, Washington 98188 • Phone: (206) 575.4404 • Fax (206) 5754439
77777777 ��1�•�'1 �.: "t. ,:YI`iJJ �' ~'.+`I�:t'�:�i11.. �1;.
yi,iyi f ;,,;rr A';7W ;:1 •! 1" ;';e; Iii l':%7 .,r:' a»
*k *4 *kkA *A ** *•***** 4***** k**A** A* k *A*A **k * * * *Ak* * *JA *A ***fiA * * * *•k
CITY OF .TUKWIL.A. WA � O j IRAN U4XT
k• A *A *kA'kk•kk•k*:t9ekk *k*Alek * *. A* *•k k A -A k*k4eA.k:kA *4*.k A A k 1•A *A A• *A *kA*
TRANSMIT Number: 94003077 ,Amount. 33.12 10/10/11VA 55
Payment Method: CHICK( Notation. PARSLEY ENGINEER :[n7i; .a[13
Permit No: M93--0121 Type. i3 t4I CHt1N MECHANICAL PERMIT
Parcel Na: 102304-9044
Site Address. 11621 EAST MARGINAL WY U
Total Fees: 122.E31
This .Payment 33.12 Total AL. I.. Ptnts. 123.8I
Balance: .00
k**• kkk* A: k• kkA>r rAA**** A** AA*;***Ak kA• * *• k**A*A *k* *AAk *****A* **A ** *A*k
Ac.couktt Cade Description Amount
000/345.830 PLAN CHICK •- NOWRES 6.62
000/322.100 MECHANICAL NOMRES 26.550
GENERA 33.12
TOTAL 33.12
CHECK 33.12
CHANGE . 0.00
6947A00 0 16:33
:•[
77173171 : `,i.i.Iii'')k��.rryyr alp¢'... .. (j 2 »b:` ;t;''P sa ••
:k *k;5• * *1. *A•k *kA * * *Ak *A t.*.*****,*. * * ** *****4*******************
CITY OF TUKWILA. WA
** ** *k * * ** * * * *A * *1. *•A ** ********** I *�**•* **k *A * ***A ** *** *k *.w ** **
I RANSMa:T Number 94002€307 Amount: 09.69 00/23/95 14:05
Payment Method CHECK Notation: NANCY PARSLEY Tni6. ,A
Permit No: M95 -0121 Type: I3-•MBCH(W MECHANICAL. PERMIT
Parcel No: , 9.021104•-9044
Site ,Address:. 11621 EAST MA11O1NAL WY S
Total fees: 89.69
This Payment 89.69 Total ALL Pints :.' 89.69
Balance: .00
: * * **1.** ****k * ** * **** ** ** A **k**** * ***•A* ** *• * *•k * ****•** *1x:1 *** * *A*
Account Code Description Amount
000/845.830 PLAN CHECK - NONRES 17.94
000/322.100 MECHANICAL - NUNRES 71.75
TRANSMIT
GENERA
GENERA
TOTAL
CHECK
CHANGE
5520A000
17.94
71.75
89.69
89:69
0.00
15:47
CITY OF TUKWILA
Address 11621 EAST MARGINAL WY S
Suite:
Tenant TRADESHOW
Type: B- MECHAN.,
Parcel #: 102304 -9044
Permit No: M95 -0121
Status ISSUED
Applied: 08/02/1995
Issued: 08/23/1995
*•k **•k* *•k•k k* k* **'b *•k k*•k•k k•k•b *•k k*•b**•k*•k•k ** k•k *'k * * * *•k•k b*•k*. *•k**•b k*•b b*****•k•k* b"k k•k **
Permit Conditions:
1. MANUFACTURERS IN TALLP1 1ON,4, IN TR:U.I TX�.ON, +� REQUIRED ON SITE
+ .•' r'':� "�^^om`.•° y��a'• »"',�
FOR THE BUILDING INSPEGTOR�-'REVTEt4 ,. t, ..,
2. No changes will ,b W'ie�- to the np l ans, un 1 essap �r;,oved by the
Architect or E�? gs %s ,e r and-, ctrl :wi(lb''ii Bui 1ding L i. °sion.
Plumbing perm' .s shall , abtla Amid thr�oug 1i a reab- f~'ing
County Dep 'r Ent ott,, :P,,. b't. i c Health. F l umbrfn r will be;�
inspected, , , f that agency, ,i n,el'ud in"g' ta41�1 ogas ;.p g
(296 -472 3/rr a "�� .cb i ti a' '` 1
4. Electri4 pee lit " shat l be Otkiped through the O. ingt
State ul ision o'f Labor nd 11dustrz e and all 'e1et'tNIal
work �i +1 "e, inspected bj ..1 ?halt agency (248-6630)% ` ¢,
5. All ,:t ni ' insp`ectio•h�4recor, s „,w ,and approved plan's $h 41
avai fy +1e,y-a,igi4the� job site pri r;� :to,..t,h,e ;tart of any ca‘;
strUc;�tio€ . •4;Thece docuirrent.s_,,aa tie to b"ei maintained and anal 1-
ab1 ',,;�unt'i�',l,;.,fin,al in�,pect..i.on apiproval.:igranted.
6. Read i ly access) b l e „'access`'to root• •roiinted egu i pment L
reolred. i - r;, ,, ;
7. A1 1 ,.,con truact i o i_` toJ - be''done . i�'n cort''f a. `$
s r ',' orr�ance'l�rii th appr >oUed'` ,.
p 1 aCi; ”. and f;regu i rements:.,of ”. thUn i f'orm?Bu'1 Tit i'ng Code (199.4.':.;;t:,;i
Edi�ti'on) a's amended Uritfoi,m Mechanical Code (1994 Edition)
and^S4We:hington State E,nergv Code (1;994,Edit -ion) . `fa
8. Val id.i,ty o.f'tPet`mit. The issuance of .0-permit. ,or app►ov411 of
plans41 spec1'fications, and compugati'9ns..shall not b0'
a permit to or an ?ap►ar,dV l of',,�" env v�io)etion
of arf_V'`''0f ta,,the`' pro'v i _=.ion: of the b'u i ird i n`g c`o.de '�dr of an ��'rs ; � 1`'
other'`or�dinance ot'F. the jurisdict /ion: Noy \perm'ixt..presuming t"p; `.
give aut; ority to vialsite or ranee1 the r.ov,i°s ons of this', �'.
code sha,;lsI be valid �' , t�{ {{fin, i /.
CITY OF TUKWILA
6300 SOUTHCENTER BOULEVARD
TUKWILA, WA 98188
RECEIVED
CITY OF TUKWILA
OCT flL1!95
PERMIT CENTER
* * REVISION SUBMITTAL * *
DATE /0
PROJECT NAME ` e T ES-4- Lc)
ADDRESS /l /ir72l � /72/947-17")/4 (t Lu9 y U 717i"
CONTACT PERSON —OA /v n 111714E TH PHONE 831 - aq,Q
ARCHITECT OR ENGINEER
PLAN CHECK/PERMIT NUMBER fq6- of )
TYPE OF REVISION:
ck 13 /r/S17/ 4, PEE/t&-CT
C0.11.e6 1)ano I O- 5-- 95. -a3
SHEET NUMBER(S)
"Cloud" or highlight all areas of revisions and date revisions.
SUBMIIT.ED TO: Ktn
,!
l;iTl' O
APPROVED
C 5 1995
BUILDING DIVISION
** PARSLEY ENGINEERING
•* MECH. ENGR /CONTRACTORS *
* * REDMOND, • :WA
**
FULL COMMERCIAL HVAC LOADS PROGRAM
BUILDING MASTER DATA AND DESIGN PARAMETERS:
DESIGN
MONTH
AUGUST
JUNE
JULY
SEPTEMBER
JANUARY
FEBRUARY
WINTER
OUTDOOR OUTDOOR
DRY BULB WET BULB
83
83
83
83
54
59 '
20
ROOF ASHRAE ROOF ROOF
TYPE ROOF # . U- F4c COLOR
1. .
PART
TYPE
.5 •, :0.100 DARK
PART COOL
U -FAC T -D
HEAT
T -D
1. 0.081 10 31
2'. 0.086 • 0 0
3. 0.050 , .10 31
WALL
TYPE
1.
ASHRAE WALL WALL
GROUP U -FAC COLOR
B 0.119 MEDIUM
67
67
67
67
48
50
0
SUSP
CLG.
YES
INDOOR
REL.HUM
50%
50%
50%
50%
50%
50%
50%
GLASS SUMMER WINTER GLASS INTERIOR
NO. U -FAC. U -FAC. SHD.COEF SHADING
1. 0.587 : 0.475 0.580 , NO
GENERAL PROJECT INFORMATION:
PROJECT FILE NAME:
PROJECT LOCATION:
BAROMETRIC PRESSURE:
ALTITUDE:
NORTH LATITUDE: .
MEAN DAILY TEMPERATURE RANGE:
ATMOSPHERIC CLEARNESS FACTOR:
GROUND REFLECTANCE: 0
STARTING TIME FOR HVAC LOAD CALCULATIONS:
ENDING TIME FOR HVAC LOAD CALCULATIONS:
FLOOR HEAT LOSS•COEFFICIENT: , ,
PROJECT:
CLIENT:
DATE:
DESIGNER:
INDOOR
DRY BULB
75
75
75
75
75
75
70
TRADESHOW
S.G.A.
07/22/95
DANOVIA MARITH
GRAINS IN /OUTDOOR
DIFF. , CORRECTION
9.25
9.25
9.25
9.25
-24.90
-25.74
0.00
-12
- 12
- 12
-12
-41
-36
INTERIOR
SHD.COEF
ROOM GLASS GLASS
CONST WIDTH HEIGHT
100.00 6.00
0.000 MEDIUM
D:95059C
TUKWILA, WA
29.491 IN.HG
400 FEET
47 DEGREES
26 DEG.F
1.00
20. PERCENT
8 AM
6 PM
0.81 BTUH /FT- '
RECEIVED
PITY OF TUKWILA
AUG 0 2 h‘)
PERMIT CENTER
NUMBER OF UNIQUE ZONES IN kS PROJECT:
•
nFa 54*St t`x:Yr1�?r ",,N'YZA,';,".' j }M: fE�. * :Gts� 6srC N+tu° 15 ter4VA3='""c3'':A*.i!LL{ili?!3 ' kt
3
.. .. '.. �..., r. �.. ,... ..,�Za,.,t t' ?, .. t,:Y ; ��.: .�: rsf �. ��[r t(+v:. +rf, i�i.'tr�t;z.;K w. pAS r:+ ;r�..,. �: r. � �, {<.r 1 5�q..,•..;;,�.s t;e te 7..q»y��,,u, 4,.. ,�,
.7 ..t. 4r .t .. ... .r.rt ..,.� *:? ..i7fY.. e.h�..>>v.. : nS�:5 �,; /, °� "'N;?cfi �•.; r;�' tYni''v.:
* ** FULL COMMERCIAL
.PARSLEY ENGINEERING
TRADESHOW
* * * ** * * * * * * * * * *• * ** * **
LOA
HVAC LOADS PROGRAM BY ELITE SOFTW
07/22/95
GENERAL PROJECT DATA (CONTINUED)
BUILDING DEFAULT VALUES:
CALCULATIONS PERFORMED:
LIGHTING REQUIREMENTS:
EQUIPMENT REQUIREMENTS:
PEOPLE SENSIBLE LOAD'MULTIPLIER:
PEOPLE LATENT LOAD MULTIPLIER:
PEOPLE OCCUPANCY BASIS:
ZONE SENSIBLE SAFETY FACTOR:
ZONE LATENT SAFETY FACTOR:
ZONE HEATING .SAFETY FACTOR:
PEOPLE DIVERSITY FACTOR:
LIGHTING PROFILE • NUUMBER:
EQUIPMENT PROFILE NUMBER:
PEOPLE PROFILE NUMBER:
BUILDING DEFAULT'CLG. HEIGHT:
BUILDING DEFAULT WALL HEIGHT:
INTERNAL OPERATING LOAD PROFILES-(C=100):
REF HR HR HR HR HR HR HR HR HR HR
NO. 1 2 3 4 5 6 7 8 9 10
HR HR
11 12
DEVELOPMENT INC * **
REDMOND, WA
PAGE 2
* ** * * * * * * * * * * * * * * * * **
BOTH HEATING AND COOLING LOADS
1.50 WATTS PER SQUARE FOOT
0.50 WATTS PER SQUARE FOOT
255 BTUHS PER PERSON
205 BTUHS PER PERSON
1 PERSON PER 150 SQ.FT
10%
10%
20%
100%
10
10
10
8.50 FEET
12.00 FEET
HR HR HR HR HR HR HR HR'HR HR•HR
13 14 15 16 17 18 19 20 21 22 23
1 C C C •C C C C C C C 70 70 70
2 . C C C C C C C C C C C C C
3 . C C C C C C C C C C C C C
4 . C C C C C 'C C C C C C C C
5 . C C C C C C C C C C ,C C C
6 . C C C C O C C C C C C C C
7 . .0 C C •C , C C C C C C C C C
8 . C C C C •C C C C C C C C C
9.• C C C C C C C C C C ,C C C
1 0 . C C C C C C C C C C C C C
ALL DESIGN DATA TAKEN FROM THE 1989 ASHRAE HANDBOOK OF FUNDAMENTALS
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
HR
24
C
C
C
C
C
C
C
C
C
C
.fir[. .. .:r. ^,'Y \ ^..::..'i; t'.^'l ".n.GtSr \�v; Y.h(:t �.,+` F': •�'. �y,.. :�.lb.
v r;,;�i; ��• .'.1„,.. , .� .T� b. .. :s'>rr �S't ;- :f.7,v�' ".•,•xi;n 4. x,?.�sir. "r•,�.v, -�s"a, .i'.. ':R;' v. `,*,X x ,?!h i+;'YAy`�;M �s.,�! ^x+ q,•t.
.�.t� t .;t�n :,:. .. ��t' �.,?:? ti&,...,' �., tx-;.. �.' db��e,.. m .r.,�'�i.`ux�'ii�:.r..,.n..+:n fd,' l�.v?;�tY.�!,asni4'n47•,n�.f%�4 r...�i��;� SY�ia �.. A�'.: ��tY :tt,urs.�'s'l� < ?.>'4:ru.r'�Lkv 1. 3' �1Vltt�, i'S.`,F,�,,;�i�v�i,��gr,�k.�i�t �.�,t?
* ** FULL COMMERCIAL HVAC L w S PROGRAM BY ELITE SOFTWA' DEVELOPMENT INC * **
•PARSLEY•ENGINEERING 'REDMOND, WA
TRADESHOW ''' . 07/22/95 PAGE 3
* * * * * * * * * * * * * * ** AIR SYSTEM # 1 .(G /E ROOFTOP) ZONE SUMMARY. * * * * * * * * * * * * * * * **
ZN. ZONE - DESCRIPTION FLOOR HTG.LOSS SEN.GAIN LAT.GAIN HTG.CFM CLG.CFM
NO. PEAK TIME & MONTH AREA O.A. CFM O.A. CFM EXH. CFM CFM /SF. CFM /SF.
1 1ST & 2ND NORTH PE 1394 45,769 38,029 .. 2,096 1,228 1,891
3.PM JUNE, 0 186 0 0.88 1.36
ZONE PEAK TOTALS , 1,394 45,769 38,029 2,096 1,228 1,891
TOTAL ZONES: 1 0 186 0 0.88 1.36.
* ** FULL COMMERCIAL HVAC LOADS PROGRAM BY ELITE SOFTW; DEVELOPMENT INC * **
PARSLEY ENGINEERING REDMOND, WA
TRADESHOW 07/22/95 PAGE 4
* * * * * * * * * * * * ** Ate' X.__. M UG /E ROOFTOP) TOTAL LOAD SUMMARY * * * * * * * * * * * **
AIR HANDLER DESC: G/E ROOFTOP WITH CV (PROPORTION) TERMINALS
SUPPLY AIR FAN: DRAW -THRU WITH PROGij,AM ESTIMATED HORSEPOWER OF 1.19 HP.
FAN INPUT: 50% COM$INED FAN AND MOTOR EFF. WITH 2.00 IN WATER ACROSS THE FAN
SENSIBLE HEAT RATZQ: 0.95 THIS SYSTEM OCCURS 1 TIME(S) IN THE BUILDING
AIR SYSTEM PEAK TIME: 3 PM IN JUNE'
OUTDOOR CONDITIONS: 83 DB, 67 WB, 74.85 GRAINS INSIDE: 75 DB, 50% RH
SUMMER: VENT CONTROLS OUTSIDE AIR WINTER: NONE CONTROLS OUTSIDE AIR
ZONE SPACE SEN'.LOSS: 33,889 BTUH
INFILTRATION SEN.LOSS:' 11,880 BTUH
OUTSIDE AIR 'SEN.'LOSS: 0 BTUH
SUPPLY DUCT SEN.LOSS: 0 BTUH
RETURN DUCT SEN.LOSS: ,, 0 BTUH
TOTAL SYSTEM SEN.LOSS:
SUPPLY AIR: 45,769 / (0.986 X 1.08 X 35) =
WINTER VENT OUTSIDE AIR (0.00% O' SUPPLY):
ZONE SPACE SEN.GAIN:
INFILTRATION SEN.GAIN:
DRAW -THRU FAN SEN.GAIN:
SUPPLY DUCT SEN.GAIN:
38,029 BTUH
0 BTUH
2,977 BTUH
0 BTUH
186 CFM)
0 CFM) '
1,228 CFM)
0 CFM)
0 CFM)
,45,769 BTUH
TOTAL SEN.GAIN ON SUPPLY SIDE OF COIL: 41,006 BTUH
SUPPLY AIR: 41,0067 (0.986 X 1.10 X 20) =
SUMMER VENT OUTSID,AIR (9.83% OF SUPPLY):
RETURN DUCT .SEN.GAIN: 0 BTUH
RETURN PLENUM SEN.GAIN: 0 BTUH
OUTSIDE AIR SEN.GAIN: 1,613 BTUH
BLQW -THRU FAN SEN,.GAIN: 0 BTUH
TOTAL SEN.GAIN ON RETURN SIDE OF COIL:
1,891 CFM)
186 CFM)
186 CFM)
1,613 BTUH
TOTAL SEN.GAIN ON AIR HANDLING SYSTEM: 42,619 BTUH
ZONE SPACE LAT.GAIN: 2,996 BTUH
INFILTRATION LAT.GAIN: • 0 BTUH
OUTSIDE AIR LAT.GAIN: 1,154 BTUH
TOTAL LAT.GAIN ON AIR HANDLING SYSTEM:
TOTAL SYSTEM SENSIBLE AND LATENT GAIN:
TOTAL TONNAGE REQUIRED WITH OUTSIDE AIR:
0 CFM)
186 CFM)
3,'250 BTUH
45,869 BTUH
i
i },`�.'F-i•.,} Jb�.J- �Y�:n�,�:]��'�S?lrt.!:tl �.:C�, ^vY.�� }la`Y?�i��
ri+'1lft't+N1' F1'iY7'uf
* ** FULL COMMERCIAL HVAC LO +SPPROGRAM BY ELITE SOFTW DEVELOPMENT INC * **
.PARSLEY ENGINEERING' • REDMOND, WA
TRADESHOW 07/22/95 PAGE 5
* * * * * * * * * * * * * * ** AIR SYSTEM # 2 (G /E, ROOFTOP) ZONE
ZN. ZONE - DESCRIPTION FLOOR HTG.LOSS SEN.GAIN
NO. PEAK TIME & MONTH AREA O.A. CFM O.A. CFM
4..
2 1ST & 2ND NORTH` PE 1248
10 : AM JUNE_
ZONE'PEAK TOTALS 1,248
TOTAL ZONES: 1'
45,800
0
45,800
0
SUMMARY
• * * * * * * * * * * * * * * * **
LAT.GAIN HTG.CFM CLG.CFM
EXH. CFM CFM /SF. CFM /SF.
51,795 1,877
166 0
51,795 1,877
166 0
1,229 2,576
0.98 2.06
1,229 2,576
0.98 2.06
1'
* ** FULL COMMERCIAL HVAC LOADS PROGRAM BY ELITE SOFTWAii; DEVELOPMENT INC * **
•PARSLEY ENGINEERING, REDMOND, WA
TRADESHOW 07/22/95 PAGE 6
* * * * * * * * * * * * ** 7`►r 1 mFM kir (G /E ROOFTOP) TOTAL LOAD SUMMARY * * * * * * * * * * * **
AIR HANDLER DESC: G/E ROOFTOP WITH CV (PROPORTION) TERMINALS
SUPPLY. AIR FAN: DRAW -THRU WITH PROGRAM ESTIMATED HORSEPOWER OF 1.62 HP.
FAN INPUT: 50 %' COMBINED FAN AND MOTOR EFF. WITH 2.00 IN WATER ACROSS THE FAN
SENSIBLE HEAT RATIO: 0.97 THIS SYSTEM OCCURS 1 TIME(S) IN THE BUILDING
AIR SYSTEM PEAK TIME: 10 AM IN JUNE
OUTDOOR CONDITIONS':. 68 DB, 64 WB, 84.10 GRAINS INSIDE: 75 DB, 50% RH
SUMMER: VENT CONTROLS OUTSIDE AIR, WINTER: NONE CONTROLS OUTSIDE AIR
ZONE SPACE SEN.LOSS:
INFILTRATION SEN.LOSS:
OUTSIDE AIR SEN.LOSS:
SUPPLY DUCT SEN.LOSS:
RETURN DUCT SEN.LOSS:
TOTAL SYSTEM SEN.LOSS:
35,198 BTUH
10,602 BTUH
0 BTUH (
0 BTUH
0 BTUH
SUPPLY AIR: 45,800 / (0.986 X 1.08 X 35)
WINTER VENT OUTSIDE, AIR (0.00% OF SUPPLY):
ZONE SPACE SEN.GAIN: 51,795 BTUH
INFILTRATION SEN.GAIN: 0 BTUH
DRAW -THRU FAN SEN.GAIN: 4,055 BTUH
SUPPLY DUCT SEN.GAIN: 0 BTUH
TOTAL SEN.GAIN ' ON• SUPPLY SIDE OF COIL:
SUPPLY AIR: 55,850 / (0.986 X 1.10 X 20) = (
SUMMER VENT OUTSIDE AIR (6.44% OF SUPPLY):
166 CFM)
0 CFM)
1,229 CFM)
0 CFM)
0 CFM)
2,576 CFM)
166 CFM)
45,800 BTUH
55,850 BTUH
RETURN DUCT SEN.GAIN: 0 BTUH
RETURN PLENUM SEN ,GAIN : ,., 0 BTUH
OUTSIDE AIR SEN.GAIN: -1,260 BTUH ( 166 CFM)
BLOW -THRU FAN'SEN:GAIN: 0 BTUH
TOTAL SEN.GAIN ON RETURN SIDE OF COIL: -1,260 BTUH
TOTAL SEN.GAIN ON AIR HANDLING SYSTEM: 54,590 BTUH
ZONE SPACE LAT.GAIN: 1,877 BTUH
INFILTRATION LAT.GAIN: ' 0 BTUH
OUTSIDE AIR LAT.GAIN: 2,058 BTUH
TOTAL LAT.GAIN ON AIR HANDLING SYSTEM:
TOTAL SYSTEM SENSIBLE AND LATENT GAIN:
TOTAL TONNAGE REQUIRED WITH OUTSIDE AIR:
0 CFM)
166 CFM)
3,935 BTUH
58,525 BTUH
-t;iz� ;y r,S', r'. a 4iT , F,R;V�X
,..;1. ..... a t .b _,.i �.. ,�: dt a��c .,.y.'._ }.., � JL.: ;.L:.4:i �F:t .
* ** FULL COMMERCIAL HVAC LOADS PROGRAM BY ELITE SOFTE DEVELOPMENT INC * **
PARSLEY ENGINEERING REDMOND, WA
TRADESHOW 07/22/95 PAGE 7
* * * * * * * * * * * * * * ** AIR SYSTEM # 3 (G /E ROOFTOP) ZONE SUMMARY * * * * * * * * * * * * * * * **
ZN. ZONE - DESCRIPTION FLOOR HTG.LOSS SEN.GAIN LAT.GAIN HTG.CFM CLG.CFM
NO.. PEAK TIME' &'•MONTH AREA O.A. CFM O.A. CFM EXH. CFM CFM /SF. CFM /SF.
3' '1ST & 2ND 'INTERIOR 3960 54,175 49,885 5,953 1,'454 2,481
6 PM JUNE, 0 528 0 0.37 0.63
ZONE PEAK TOTALS 3,960 54,175 49,885 5,953 1,454 2,481
TOTAL ZONES:' 1' 0 528 0 0.37 ' 0.63
•
•
.
* ** FULL COMMERCIAL HVAC LOADS PROGRAM BY ELITE SOFTW
-PARSLEY ENGINEERING.
TRADESHOW 07/22/95
* *, * * * *. * * * * * * * *gi'i li (G /E ROOFTOP) TOTAL LOAD
DEVELOPMENT INC * **
REDMOND, WA
PAGE 8
SUMMARY * * * * * * * * * * * **
AIR HANDLER DES.C: G/E ROOFTOP WITH CV (PROPORTION) TERMINALS
SUPPLY AIR FAN: DRAW —THRU WITH PROGRAM ESTIMATED HORSEPOWER OF 1.56 HP.
FAN INPUT: 50t COMBINED FAN AND MOTOR EFF. WITH 2.00 IN WATER ACROSS THE FAN
SENSIBLE HEAT .RATIO: 0.90 THIS SYSTEM OCCURS 1 TIME(S) IN THE BUILDING
AIR SYSTEM PEAK TIME: 5 PM IN'JUNE
OUTDOOR CONDITIONS: 80 DB, 67 WB, 79.69 GRAINS INSIDE: 75 DB, 50% RH
BECAUSE OF THE DIVERSITY IN ZONE, PLENUM, AND VENT. LOADS, THE ZONE SENSIBLE
PEAK TIME IN JUNE ' AT 6 PM IS DIFFERENT FROM THE TOTAL SYS. PEAK TIME
HENCE, THE AIR SYSTEM CFM WAS COMPUTED USING A ZONE SEN. LOAD OF 49,885
SUMMER: VENT CONTROLS OUTSIDE AIR '
ZONE ' SPACE
INFILTRATION
OUTSIDE AIR
SUPPLY DUCT
RETURN DUCT
TOTAL SYSTEM
SEN:LOSS:
SEN . %QSS :
SEN.LOSS:
.SEN.LOSS:
SEN.LOSS:
SEN.LOSS:
WINTER: NONE CONTROLS OUTSIDE AIR
20,452 BTUH
33,723 BTUH
0 BTUH
0 BTUH
0 BTUH
SUPPLY AIR: 54,175 / (0.986 X 1.08 X 35) = (
WINTER VENT OUTSIDE AIR (0.00% OF SUPPLY):
ZONE SPACE SEN.GAIN: 49,885 BTUH
INFILTRATION .SEN.,GAIN: 0 BTUH
DRAW —THRU FAN SEN.GAIN: 3,905 BTUH
SUPPLY DUCT SEN.GAIN: 0 BTUH
TOTAL SEN.GAIN ON SUPPLY SIDE OF 'COIL:
SUPPLY AIR: 53,790 / (0.986 X 1.10 X 20) =
SUMMER VENT OUTSIDE AIR (21.3% OF SUPPLY):
RETURN DUCT SEN.GAIN: 0 BTUH
RETURN PLENUM•SEN.GAIN: 0 BTUH
OUTSIDE AIR SEN.GAIN: 2,862 BTUH
BLOW —THRU FAN SEN:GAIN: 0 BTUH
TOTAL SEN.GAIN ON RETURN SIDE OF COIL:
♦ 1
TQTAL.SEN.GAI1•ON•AIR HANDLING SYSTEM:
ZONE SPACE LATGAIN: 5,953 BTUH
INFILTRATION LAT.GAIN: 0 BTUH
OUTSIDE AIR LAT:GAIN: 4,988 BTUH
TOTAL LAT.GAIN ON AIR HANDLING SYSTEM:
TOTAL SYSTEM SENSIBLE AND LATENT GAIN:
TOTAL TONNAGE•'REQUIRED WITH OUTSIDE AIR:
528 CFM)
0 CFM)
1,454 CFM)
0 CFM)
0 CFM)
2,481 CFM)
528 CFM)
528 CFM)
0 CFM)
528 CFM)
54,175 BTUH
53,790 BTUH
2,862 BTUH
56,652 BTUH
10,941 BTUH
67,593 BTUH
UMW
E+z•
* ** FULL COMMERCIAL HVAC LO S PROGRAM BY ELITE SOFTWAR ;DEVELOPMENT INC * **
PARSLEY ENGINEERING REDMOND, WA
TRADESHOW 07/22/95 PAGE 9
* * * * * * * * * * * * * * * * * * * * * * ** TOTAL BUILDING LOAD SUMMARY * * * * * * * * * * * * * * * * * * * * * **
BUILDING PEAKS IN JUNE AT 3 PM
BLDG. LOAD AREA
DESCRIPTIONS QUAN
SEN. tTOT
LOSS LOSS .
LAT.
GAIN
+ SEN.
GAIN
= TOTAL %TOT
GAIN GAIN
ROOF 3,315 19,890 13.65
WALL 1,500 . 10,709 7.35
GLASS 1,500 42,750 29.33
FLOOR SLAB 124 6,028 4.14
0 13,856
0 713
0 .50,189
0 0
13,856 8.47
713 0.44
50,189 30.68
0 0.00
SKIN LOADS 6,315 79,377 54.46
0 64,758
64,758 39.58
LIGHTING
EQUIPMENT
PEOPLE
PARTITION'
VENT 0
INFL' 880
Dk2AW -THRU FAN
BLOW -THRU FAN
SUPPLY DUCT
RETURN DUCT
'9,903'
3.,307.
43
• 8, 90'8
880
0
0 0.00
0 0.00
0 0.00
10,164 6.97
0 0.00
56,205 38.56
0 0.00
0 0.00
0 0.00
0 •'0.00
0 37,146
0 12,383
12,346
0 3,006
7,633
9,926
5,460
0 0
0 10,937
0 0
0 0
0 0'
BUILDING TOTALS 145,746'10'0.00 15,386
148,209
37,146 22.71
12,383 7.57
22,272 13.61
3,006 1.84
13,093 8.00
0 0.00
1p,937 6.69
0 0.00
0 0.00
0 0.00
..
163,595 100.00
BUILDING SUMMARY
LOAD DESCRIPTIONS
SEN. TOT LAT.
LOSS LOSS GAIN
+ SEN.
GAIN
= TOTAL %TOT
GAIN GAIN
VENTILATION
INFILTRATION
ZONE LOADS
PLENUM LOADS
FAN & DUCT LOADS
0 0.00
56,205 38.56
89,541 61.44
0 o.od
0 0.00
5,460
7,633
0 0
129,639
0 0
0 10,937
9,926
13,093 8.00
0 0.00
139,565 85.31
0 0.00 '
10,937 6.69
BUILDING TOTALS 145,746 100.0'0 15,386
148,209
163,595 100.00
TOTAL BUILDING SUPPLY AIR (BASED ON A 20 TD):
TOTAL BUILDING VENT AIR (12.60 OF SUPPLY):
TOTAL CONDITIONED AIRSPACE:
SUPPLY AIR CFM /SQ'.FT. OF CONDITIONED SPACE:
SQ.FT OF CONDITIONED AIR.SPACE,PER TON:
TONNAGE PER SQ.FT OF CONDITIONED AIR SPACE:
TOTAL HEATING REQUIRED WITH OUTSIDE AIR:
TOTAL TONNAGE REQUIRED WITH OUTSIDE AIR:
6,948 CFM
880 CFM
6,602
1.0524
484.2691
0.0021
SQ.FT
CFM /SQ.. FT
SQ.FT /TON •
TONS / SQ.FT
City 6. Tukwila
FIRE DEPARTMENT
444 Andover Park East
Tukwila, Washington 98188 -7661
(206) 575 -4404
John W. Rants, Mayor
August 15, 1995
Fire Department Review
Control #M95 -0121
(510)
Re: Trade Show - 11621 East Marginal Way South
Dear Sir:
The attached set of building plans have been reviewed by
The Fire Prevention Bureau and are acceptable with the
following concerns:
1. H.V.A.C. units rated at 2,000 cfm require
auto - shutdown devices. These devices shall be separately
zoned in the alarm panel and local U.L. central station
supervision is required. (City Ordinance #1646)
Smoke detectors required by Uniform Mechanical Code
Section 1009 (a), (HVAC 2000 cfm and greater), shall
be installed in the main return -air duct ahead of any
outside air inlet or they may be installed in each
room or space served by the return -air duct.
Detectors shall also be installed in the supply duct,
downstream of the filters. Activation of any detector
shall cause the air - moving equipment to automatically
shutdown.
2. All new fire alarm systems or modifications to
existing systems shall have the written approval of The
Tukwila Fire Prevention Bureau. No work shall commence
until a fire department permit has been obtained. (City
Ordinance #1646) (UFC 10.503)
3. All electrical work and equipment shall conform
strictly to the standards of The National Electrical Code.
(NFPA 70)
This review limited to speculative tenant space only -
special fire permits may be necessary depending on detailed
description of intended use.
City Cr Tukwila
FIRE DEPARTMENT
444 Andover Park East
Tukwila, Washington 98188 -7661
(206) 575 -4404
John W. Rants, Mayor
Page number 2
Any overlooked hazardous condition and /or violation of the
adopted Fire or Building Codes does not imply approval of
such condition or violation.
Yours truly,
The Tukwila Fire Prevention Bureau
cc: T.F.D. file
ncd
PLEASE DETACH AND SIGN •
CERTIFICATE BEFORE PLACING
IN BILLFOLD
' ak•'
r E
' . E;pt.. 6 •' R A.O S. y �g1'B�Y. �lA� WJ iAS`.�' � }; ` i•• j )1j 4 �+j. 4 •
' a l;:* i., :•10.l{.ZT.{:J-M.t'.41tr;1 +. r• •417wY' 1 4
•rli
P �at6it::i
SIGNATURE
.te
ISSUED By DEPA'' MENT 'f` LABOR AND I ;rjUSTRIES
.bscribed and sworn before me this
•
a/ 67
day of
19
)tart' Pub «''
v
y Commlss on Expires: ""
3/995-
PA-R5L 1077M {
BY: (/
. TITLE:
F625-052-000 (3-B2)
/ A
i4 TRACTOR,SUPpiIER
sueco
‘,6Ar(authorizod 5)gnaluro)
10 "C.D.
410CFM
EC. D.
140 CFM
PA /Nl- AYS/D6
2//4D8 rolsr8
E3"c.o.
235 CFM
B "R•6-
235CF"
"45
!"90 CFM
C.O.
CFM
log R:G•
-44o-CFM -
/0 "CD.
350 CFM
565CFM
/O "146.
320 CFM
I2Q TIE IN TO 2ND FLOOR VENT.
FIRST FLOOR
/
SHEET METAL NOTES
MISCELLANEOUS:
DUCT BOARD SIZES INDICATED ON PLANS ARE NET INSIDE DIMENSIONS. A
CALL -OUT SUCH AS 12112- 13132 MEANS A DUCT CONSTRUCTED OF 2. THICK
,DUCTBOARDWITH A I2" z.12" NET INSIDE DIMENSION, GIVING AN OUTSIDE -
DIMENSION OF 16" x 16 ". UNLESS INDICATED AS 2 ", ALL DUCTBOARD SHALL
E,1 7.THICK: •
2. �'THESE PLANS:HAVE BEEN COORDINATED WITH THEARCIDIECTURAL AND
•STRUCTURAL DRAWINGS.' ANY CHANGESINTFDS LAYOUT MAY REQUIRE
•RECOORDINATION.
IN GENERAL, FINISH CEILING HEIGHT IN OFFICE AREAS WILL BE 8'-6" ABOVE
-FINISHED FLOOR (AF.F) TO BOTTOM OF CEILING TO ALLOW 6" FOR - -
RECESSEDLIGHT FIXTURES, DUCTWORK SHALL BE INSTALLED NO LOWER
THAN 9'- 0 ".AF.F. EXCEPT AS NOTED.
GENERAL NOTES
24
NCb
4"./2.
/2'x4E11i i2' rq /T.G•
PAINT /AIRIDE SLACK
!O' C•D
Z75 CFM
10' "W G. /F.O.
:435• CFM
TO13 SITE
llG7/ A MARGINAL
8 "C. D.
220 CFM
8" C.D.
210 CFM
1G / /6D8 _TIIRURB4
/2//0 DS z
K & +17! ROOF
® dV RcoF
/6/16 DB T//RV ROOF
/6//4 DBe
IG✓!b DS` TIIRU ROOF
SR 599
0_ SITE PLAN
IV0 SCALE
ON ROOF:
TINT INS /T.L ELAC/(
GENERAL NOTES
150 CFM
EQUIPMENT SCHEDULE
/20 CFM:
24 VE/Vr UP 1O 6005ENeF'(
AL RoOF W rN 1/2 ` SI kDYREEN
dvER OPEN /NG•
AIR CONDITIONING I1NIT9
AC -I, 2 NOMINAL 4 TON, PACKAGE ROOFTOP GAS/ELECTRIC AIR CONDITIONING
UNIT, YORK' MODEL DECG048N06046. COOLING CAPACITY AT 95° F
OUTDOORS, 80°F, DRY BULB /64 °F WET BULB ENTERING INDOOR COIL: 51
MBFI TOTAL, 37 MBH SENSIBLE. COOLING EER= :9.45: SEER= 10.35. 1,600
. CFM SUPPLY AIR AT 031" ESP, HIGH SPEED.. 460/3/60, 12.5 MCA, 15 MFS, 15
AMP MAX HACR - BREAKER WEIGHT= 645 LBS.
NOMINAL 6 TON, PACKAGE ROOFTOP GAS/ELECTRIC AIR CONDITIONING
UNIT WITH ECONOMIZER AND FAROMETRIC RELIEF HOOD, YORK MODEL
D6CG076N07946EB. COOLING CAPACITY AT 95° F OUTDOORS, 80°F DRY
BULB /64°F WET BULB ENTERING INDOOR COIL: 80 MBH TOTAL, 56 MBH
SENSIBLE. COOLING EER= 9.00: 2,400 CFM SUPPLY AIR AT 0.70" ESP, 1081
RPM, BELT DRIVE MOTOR 4600/60, 21.0 MCA, 25 MFS, 25 AMP MAX HACR
BREAKER. WEIGHT =725 LBS.
THERMOSTAT
TI, 12 7- DAY, PROGRAMMABLE ELECTRONIC THERMOSTAT.
HONEYWELL 7200A1006.
SECOND FL;
)/8 ♦ /' -0°
' ALLIRADES T° LEAVE 36. CLEARANCE IN FRONT OF AIR CONDITIONING
MITT AND OTHERMECHANICAL EQUIPMENT ACCESS PANELS FOR
SERVICING.
..:: GENERALCONT3.RACTOR COORDINATION:
2 ACCESS TO FIRE DAMPERS, BALANCING DAMPERS, DUCT ACCESS PANELS,
AND EQUIPMENT ABOVE THECEILINGSHALL BE ASSURED AND PROVIDED
BYTHEGENERAL CONTRACTOR_ .LAY-IN CEDSNGSCONSDTUTE SUITABLE
ACCESS. -SHEET ROCK, SPLINED, WOODEN; ETC WALLS ORCEILINGS WOULD
REQUIRE AMINIMUM 22" 822 "_M1LCOR (OR EQUAL )-ACCESS DOOR OF SIMILAR
RATINGTO WALUCEE.INGPROVIDED BY THEGENERALCONTRAC TOR
LOCATION OF SUCH ACCESS DOORS WILL BE COORDINATED BY
MECHANICAL CONTRACTOR..
4. -.. 90 DUCTBOARD ELBOWS SHALL HAVE TURNING VANES INSTALLED IN EACH
TAB.
ROOFTOP PACKAGED AIR CONDITIONING SYSTEMS:
SUPPLYDISTRIBUTI: ON FROM AIR CONDITIONTNGUNITS TO DIFFUSERS
SHALL BE AS FOLLOWS:.
A. VERTICAL DROPS FROM ROOFTOP A/C UNITS SHALL BE I" OR 2" THICK:
AS INDICATED, UL. LISTED, CLASS 1 FIBERGLASS DUCT BOARD EXCEPT
WHERE LINED SHEET METAL IS INDICATED
B. FABRICATE AND INSTALL PER SMACNA I2" PRESSURE
CLASSIFICATIONS. SUPPLY AIR DISTRIBUTION DUCTWORK FROM
VERTICAL DROPS TO DIFFUSERS SHALL BE SAME AS VERTICAL DROPS.
C FLEXIBLE DUCT RUNOUTS TO DIFFUSERS SHALL HAVE 1" OR 2"
INSULATION AS INDICATED ON PLANS.
D. WHERE RETURN AIR IS DUCTED, RETURN AIR DUCTWORK SHALL BE
THE SAME PS FOR SUPPLY (SEE "B" AND "C" ABOVE).
OILET EXHAUST- DUCT WORK:
CUTTING, FRAMING, PATCHING, SEALING, AND PAINTING OF WALL, CEILING,..
AND FLOOR OPENINGS SHALL BE BY GENERAL CONTRACTOR
ROOF. CURBS,FLASHINGS, SLEEPERS, ADDITIONAL STRUCTURAL SUPPORTS,
AND CUTTING AND :PATCHING -OF ROOF OPENINGS SHALL BE BY GENERAL
CONTRACTOR. (SEE NOTE #5 BELOW).
ROOFTOP' "AIR CONDITIONERS ARE FURNISHED WITHFACTORY CURBS
REQUIRING INSULATION, CANT STRIP, ROOFING, AND COUNTER FLASHING
BY GENERAL CONTRACTOR CURB SHALL BE ASSEMBLED AND SET IN PLACE
BY MECHANICAL CONTRACTOR LEVELING, TRUING, AND FASTENING TO
ROOF STRUCTURE SHALL BE BY GENERAL CONTRACTOR, AS FOLLOWS:
6.
6. TOILET EXHAUST DUCT SHALL BE UNLINED GALVANIZED SHEET METAL
(UNLESS OTHERWISE INDICATED), WIT .UNINSULATED FURNACE PIPE
RUNOUTS AND. "HARD" CONNECTIONS TO REGISTER CANS (DO NOT USE
FLEXIBLE DUCT IPTOILET EXHAUST SYSTEMS). FABRICATE AND INSTALL.
PERSMACNAi2 PRESSURE CLASSIFICATION.
FIRE D
A. MAXIMUM ALLOWABLE SLOPE END - TO-END IS 12"
B. MAXIMUM ALLOWABLE SLOPE SIDE - TO-SIDE IS 12"
C. - TOP OF CURB MUST BE TRUE (FLAT) TO PROVIDE ACCEPTABLE MATING
.AND SEALING SURFACE.
D. - ROOF CURB MUST BE SECURELY FASTENED TO STRUCTURAL SUPPORT
MEMBERS.
WHERE INDICATED IN GRILLE, REGISTER AND DIFFUSER SCHEDULE, SOME
ITEMS WILL BE FURNISHED WITH A FACTORY APPLIED PRIME COAT FINISH.
FINAL PAINTING SHALL BE DONE BY GENERAL CONTRACTOR.
-7- THE GENERAL CONTRACTOR SHALL PROVIDE A 1" CUT AT THE FOLLOWING
DOORS: WOMENS ROOM DOOR #19, MEN'S ROOM DOOR #20, RESTROOM
DOOR #51 AND RESTROOM DOOR #5j.
mqoii
FIRE DAMPERS SHALL BE IN THE AIR STREAM TYPE, UNLESS NOTED
OTHERWISE..
DUCT: CONSTRUCTION: -:
8. DUCT MATERIALS AND CONSTRUCTION METHODS:
A. '.SHOP FABRICATED DUCTS, ALUMINUMFLEXBLE DUCT, AND WRAPPED
FLEXIBLE DUCT SHALL BE LISTED AND LABELED UL -181
FOR I I,, USE.
B. DUCT LINER AND DUCT INSULATION SHALL BE LISTED UL -723, CLASS 1
WITH A rLAME .SPREAD RATING LESS THAN 25, AND SMOKE DEVELOPED
RATING NOT OVER 50..,
C. DUCT BOARD: 1" OR 2" THICK AS INDICATED ON PLANS. UL. LISTED,
CLASS 1FBERGLASS DUCT BOARD FABRICATED AND INSTALLED PER
SMACNA STANDARDS AND THE MANUFACTURER'S
RECOMMENDATIONS. USE ONLY HEAT BONDING TAPE. PRESSURE -.
SENSITIVE TAPE IS NOT ACCEPTABLE.
D. .INSULATED FLEX DUCT: TITERMAF.LEX GKM 1" OR 2" AS INDICATED ON
PLANS'
ALL DUCTWORK SHALL BE SEALED ks FOLLOWS:
B. ON LOW PRESSURE DUCTWORK, DUCTBOARD IS SEALED ON BOTH
' TRANSVERSE AND LONGITUDINAL JOINTS...
ELECTRICAL`COORDINATION -,
8. EXFIAUSTFM U$ TENSINF, BATHROOMSSNALLBAVESEPARATEWAL_L
SWITCH . SB) ITCHINGWF47 'M'ITSISNOTACCEPTABLE. ELECTRICAL
CONTRAGTORSiH:A71- STALCSWTPCHANDDO ALL WIRING.
t
9 ELBCTRICALCONTRACTORSBALLPROVIDESERVICEPOWERAT '
'?. MECHANICALBQUSP,MENT IN'ACCORDANCE WTTB I991 UMCAND CITY OF
TLIKWILA REQUIREMEIS
10. CONDUIT, FORROOFTOPA/. CUNEFPOWERSHALLBESTUBEED- 9,"
ROOFOUTSIDRA/CUN_ETCURB. THERMOSTAT.CABLECANBEBROUGHTUP
`. INSIDECURB
11' SMOKEDETECTORWILLBEREQUIREDAT ;WESUPPLYDUCTFORAC -3.
SILEOKEDETECTORSHALL BE BYELECTRICAI .CONTRACTOR
PLUMBING COORDINATION:
12' PI: UMBERSITAL.LROUTEPLUMBINGVENTSSO AS TO MAINTAIN MINIMUM IO'
OF, CLEAR5NtrEFROM_OUTSIDEAIRNTAKES UNROOF.
PLUMBIIGCONTRACTOR SHALL INSTALLA CONDENSATE:TRAP AT EACH
ROOFTOP AIR CONDl'1TIONINGUNIT. MINI1vIUM TRAP DEPTH SHALL BE 2" (NET
ALL CONDENSATE DRAINS FROMA/C UNCES.AND GAS PIPINGAREBY
: PLUMBING CONTRACTOR- REEERTO SHEEI`M- 1.FORPLUMBING
COORDINATION:
STRUCTURAL COORDINATION:
7 -DAY, PROGRAMMABLE ELECTRONIC THERMOSTAT.
HONEYWELL 7301A1005 WITH:Q7300A1018 SUBBASE..
EXHAUST FANS
EF -1 : CEILING EXHAUST FAN. BROAN MODEL 363H. 300 CFM @ 0.125" FSP, 1625
_ RPM, 4.0 SONES. 120 /1/60, 2.3 AMPS, 165 WATTS. SEPARATE WALL SWITCH
BY ELECTRICAL CONTRACTOR.
CEILING EXHAUST FAN. BROAN MODEL 36211. 200 CFM @ 0.130" ESP, 1250
RPM; 2.0 SONES. 120/1/60, 1•.3 AMPS, 115 WATTS. SEPARATE WALL SWITCH
BY ELECTRICAL CONTRACTOR.
EF -3, 4 ., CEILING EXHAUST FAN. GROAN MODEL 360. 100 CFM @ 0.127" ESP, 1325
RPM, 1.5 SONES. 120/1/60, 0.7 AMPS, 80 WATTS. SEPARATE WALL SWITCH BY
ELECTRICAL CONTRACTOR.
15. UNIT WEIGHTS AND LOCATIONS HAVE BEEN COORDINATED WITH
ARCHITECT AND STRUCTURAL ENGINEER TO DETERMINE BUILDIN G
STRUCTURAL ADEQUACY. IF IT ISNECESSARY TO RELOCATE A UNIT,
RECOORDINATION WITH THESEFARTIES WILL BE NECESSARY.
16 ALL EQUIPMENT AND PIPING WHICH IS TO BE SUSPENDED FROM ROOF
SHALL' BE SUSPENDED FROM GLU-LAMS WHERE PRACTICAL, OR FROM
TRUSSES:: DONOT SUSPEND FROM STIFFENERS. FOLLOW
MANUFACTURER'S REQUIREMENTS WHEN ATTACHING HANGERS TO
TRUSSES.
GRILLE & DIFFUSER SCHEDULE
CEILING SUPPLY DIFFUSERS:
C.D.
CEILING DIFFUSER (LAY -IN T -BAR CEILING)
4 -CORE ADJUSTABLE, WITHOUT O.B.D. . WITH FILLER PANEL FOR
24"x24" LAY-IN MODULE.
• KRUEGER SERIES 1244, FRAME 23..
FINISH: WHITE BAKED ENAMEL:(PAINTABLE)
WALL SUPPLY:
W.GJF.D. SIDEWALL SUPPLY GRILLE WITH FIRE DAMPER
DOUBLE DEFLECTION, VERTICAL FRONT BLADES, NO O.B.D.
KRUEGER MODEL 880V WITHOUT 0.13a
FINISH: FACTORY APPLIED PRIME COAT (PAINTABLE)
RETURN AIR GRILLE
ALUMINUM EGG CRATE LOUVER
1/2 .12"x12' CORE
COLOR: ALUMINUM
R.G.
TRANSFER GRILLES:
T.G.
TRANSFER GRILLE
SAME AS R.A.G. ABOVE
NOTE:
MAKE AND MODEL NUMBERS,ARE LISTED ONLY TO
PERFORMANCE AND STYLE;' EQUAL PRODUCTS BY OTHER
MANUFACTURERS MAY BESUBSTI.1'(JTED.
SCOPE OF %YORK
NOTE: THE TERM " PROVIDE" MEANS TO FUR:'ITH /.5813 INSTALL.
1. PROVIDE THREE (3)NEW ROOFTOP, GAS/ELECTAIC, PACKAGE AIR CONDITIONING UNITS
TOTALING 14 TONS. PROVIDE NEW SUPPLY AND RETURN DUCTWORK WITH CEILING
DIFFUSERS AND RETURN. GRILLES.
2. PROVIDE THREE (3) 7 -DAY, PROGRAMMABLE THERMOSTATS.
3. PROVIDE FOUR. (4) NEW CEILING EXHAUST FANS TO EXHAUST RESTROOMS.
4. PERFORM CHECK, TEST, AND START ON PACKAGE AIR CONDITIONING UNIT. AIR
BALANCE SYSTEMS TO +/- 10% OF CFM'S SHOWN ON DRAWING.
5. GAS PIPING AND CONDENSATE DRAINS FOR AIR CONDITIONING UNITS SHALL BE BY
PLUMBING CONTRACTOR.
6. TIE IN TO SMOKE DETECTOR FOR THE SUPPLY DUCT ON AC -3. SMOKE DETECTOR SHALL
BE BY ELECTRICAL CONTRACTOR.
PROJECT NAME:
JURISDICTION: . .
ASSESSOR NUMBER:
BUILDING PERMIT #:
PROJECT ADDRESS:
TENANT:
GENERAL CONTRACTOR:
MECH. CONTRACTOR:'.
HVA,C CONTRACTOR:.
PERMIT JNFORMATION
TRADESHOW
CITY OF TUKWILA
102304 -9044
B95 -0115
11621 EAST MARGINAL WAY SOUTH
TUKWILA, WA
TRADESHOW CONVENTION SERVICES, INC.
SGA
STATE MECHANICAL
PARSLEY ENGINEERING, INC.
4620 - 232ND AVENUE NE
REDMOND, WA 98053 ,
(206)836 -2926
CONTACT: BONN M. PARSLEY, PE
WA STATE CONTRACTOR LIC. #: PARSLEI 077 -MK
I understand th�dt the PIarYCheck approva
ri6atrdepp o a
'^echo eriot'autoM"l .violation "' "v
mans does no% R 8 4 lNCeipt ^I co ^"
c :pled c.°°, rovod-plxdsacknowled9ed
actor's coYofapp
cm REC oP EIVED ruxvnu
AUG G 2 1995
PERMIT CENTER
6
DATE OF IAST REVISION:
7/3// 95
DRAWING
(REV /)
SHEET OF L