HomeMy WebLinkAboutPermit D06-331 - Best Bagels - Tenant ImprovementBEST BAGELS 4445 S 134 PL D06 -331 Parcel No.: 2613200086 Address: 4445 S 134 PL TUKW Suite No: City or Tukwila Tenant: Name: BEST BAGELS Address 4445 S 134 PL, TUKWILA WA Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: ci.tukwila.wa.us Owner: Name: FOSTORIA PARK ASSOCIATES L Address: 1805 136TH PL NE, BELLEVUE WA, 98005 Phone: Contact Person: Name: DAVID KEHLE Address' 12720 GATEWAY DR, SEATTLE WA, 98168 Phone: 206 - 433 -8997 Contractor: Name: OWNER AFFIDAVIT - ALLAN THORNE Address: BEST BAGEL, Phone: Contractor License No: doc: IBC - PERMIT DEVELOPMENT PERMIT **continued on next page** Expiration Date: Steven M. Mullet, Mayor Steve Lancaster, Director Permit Number D06 -331 Issue Date: 10/13/2006 Permit Expires On: 04/11/2007 DESCRIPTION OF WORK: TENANT IMPROVEMENT - CONVERT AN EXISTING WINDOW MANUFACTURING USE TO A BAKERY FOR BAGELS. CONSTRUCT A NON - BEARING WALL AT RESTROOM VESTIBULE. REMOVE EXISTING OFFICE COUNTER AND INSTALLNEW HAND SINK AND INSTALL 3 COMPARTMENT SINK. INSTALL BAKERY EQUIPMENT. NO CHANGE TO BUILDING ENVELOPE OR LIGHTING. Value of Construction: $10,000.00 Fees Collected: $375.06 Type of Fire Protection: SPRINKLERS International Building Code Edition: 2003 Type of Construction: VB Occupancy per IBC: 0010 1306 -331 Printed: 10-13-2006 Public Works Activities: Channelization / Striping: N Curb Cut / Access / Sidewalk / CSS: N Permit Center Authorized Signature: "71// l ' d �N doc: IBC- PERMIT City oTukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tulcwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: ci.tukwila.wa.us Fire Loop Hydrant: N Number: 0 Size (Inches): 0 Flood Control Zone: N Hauling: N Start Time: End Time: Land Altering: N Volumes: Cut 0 c.y. Fill 0 c.y. Landscape Irrigation: N Moving Oversize Load: N Start Time: End Time: Sanitary Side Sewer: 14 Sewer Main Extension: 14 Private: Public: Storm Drainage: 14 Street Use: 14 Profit: 14 Non - Profit: N Water Main Extension: N Private: Public: Water Meter: N Steven M. Mullet, Mayor Steve Lancaster, Director Permit Number D06 -331 Issue Date: 10/13/2006 Permit Expires On: 04/11/2007 Date: /0 I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance work. I am authorized to sign and obtain this development permit. Signature: 1CXYvo S Date: (37 /3 72- v 0 6 Print Name: ►A LL P nv S ��SI Chi"• v ` This permit shall become null and void if the work is not commenced within 180 days from the date of issuance or if the work is suspended or abandoned for a period of 180 days from the last inspection. 006 -331 Printed: 10-13-2006 Parcel No.: 2613200086 Address: 4445 S 134 PL TUKW Suite No: Tenant: BEST BAGELS City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: citukwila.wa.us 1: ** *BUILDING DEPARTMENT CONDITIONS * ** PERMIT CONDITIONS Steven M. Mullet, Mayor Steve Lancaster, Director Permit Number: D06331 Status: ISSUED Applied Date: 08/3112006 Issue Date: 10/13/2006 2: No changes shall be made to the approved plans unless approved by the design professional in responsible charge and the Building Official. 3: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center (206/431- 3670). 4: All permits, inspection records, and approved plans shall be at the job site and available to the inspectors prior to start of any construction These documents shall be maintained and made available until final inspection approval is granted. 5: All construction shall be done in conformance with the approved plans and the requirements of the International Building Code or International Residential Code, International Mechanical Code, Washington State Energy Code. 6: All wood to remain in placed concrete shall be treated wood. 7: All rack storage requires a separate permit issued through the City of Tukwila Permit Center. Rack storage over 8 -feet in height shall be anchored or braced to prevent overturning or displacement during seismic events. The design and calculations for the anchorage or bracing shall be prepared by a registered professional engineer licensed in the State of Washington. 8: There shall be no occupancy of a building until final inspection has been completed and approved by Tukwila building inspector. No exception. 9: Remove all demolition rubble and loose miscellaneous material from lot or parcel of ground, properly cap the sanitary sewer connections, and properly fill or otherwise protect all basements, cellars, septic tanks, wells, and other excavations. Final inspection approval will be determined by the building inspector based on satisfactory completion of this requirement. 10: Manufacturers installation instructions shall be available on the job site at the time of inspection. 11: Water heaters shall be anchored or strapped to resist horizontal displacement due to earthquake motion. Strapping shall be at points within the upper one -third and lower one -third of the water heater's vertical dimension. A minimum distance of 4- inches shall be maintained above the controls with the strapping. 12: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the Cityof Tukwila Permit Center. 13: All electrical work shall be inspected and approved under a separate permit issued by the Washington State Department of Labor and Industries (206/248- 6630). doc: Conditions 006-331 Printed: 10 -13 -2006 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: rtiukwila.wa.us 15: ** *FIRE DEPARTMENT CONDITIONS * ** Steven M. Mullet, Mayor Steve Lancaster, Director 14: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. 16: The attached set of building plans have been reviewed by the Fire Prevention Bureau and are acceptable with the following concerns: 17: The total number of fire extinguishers required for a light hazard occupancy with Class A fi re hazards is calculated at one extinguisher for each 3,000 sq. ft. of area. The extinguisher(s) should be of the "all purpose" (2A, 10 B:C) dry chemical type. The travel distance to any extinguisher must be 75' or less. (IFC 906.3) (NFPA 10, 3- 2.1)(office area) 18: The total number of fire extinguishers required for an ordinary hazard occupancy with Class A fire hazards is calculated at one extinguisher for each 1,500 sq. ft. of area. The extinguisher(s) should be of the "All Purpose" (2A, 20B:C) dry chemical type. Travel distance to any fire extinguisher must be 75' or less. (IFC 906.3) (NFPA 10, 3- 2.1)(bakery area) 19: Portable fire extinguishers, not housed In cabinets, shall be installed on the hangers or brackets supplied. Hangers or brackets shall be securely anchored to the mounting surface in accordance with the manufacturer's installation instructions. Portable fi re extinguishers having a gross weight not exceeding 40 pounds (18 kg) shall be installed so that its top is not more than 5 feet (1524 mm) above the floor. Hand -held portable fire extinguishers having a gross weight exceeding 40 pounds (18 kg) shall be installed so that its top is not more than 3.5 feet (1067 mm) above the floor. The clearance between the floor and the bottom of the installed hand -held extinguishers shall not be less than 4 inches (102 mm). (IFC 906.7 and IFC 906.9) 20: Fire extinguishers shall not be obstructed or obscured from view. In rooms or areas in which visual obstruction cannot be completely avoided, means shall be provided to indicate the locations of the extinguishers. (IFC 906.6) 21: Extinguishers shall be located in conspicuous locations where they will be readily accessible and immediately available for use. These locations shall be along normal paths of travel, unless the fire code official determines that the hazard posed indicates the need for placement away from normal paths of travel. (IFC 906.5) 22: Fire extinguishers require monthly and yearly inspections. They must have a tag or label securely attached that indicates the month and year that the inspection was performed and shall Identify the company or person performing the service. Every six years stored pressure extinguishers shall be emptied and subjected to the applicable recharge procedures. If the required monthly and yearly inspections of the fi re extinguisher(s) are not accomplished or the inspection tag is not completed, a reputable fire extinguisher service company will be required to conduct these required surveys. (NFPA 10, 4 -3, 4-4) 23: Egress doors shall be readily openable from the egress side without the use of a key or special knowledge or effort. (IFC 1008.1.8.3 subsection 2.2) 24: Dead bolts are not allowed on auxiliary exit doors unless the dead bolt is automatically retracted when the door handle is engaged from inside the tenant space. (IFC Chapter 10) 25: Door handles, pulls, latches, locks and other operating devices on doors required to be accessible by Chapter 11 of the International Building Code shall not require tight grasping, tight pinching or twisting of the wrist to operate. (IFC 1008.1.8.1) doc: Conditions D06 -331 Printed: 10 -13 -2006 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: rttukwila.wa.us Steven M. Mullet, Mayor Steve Lancaster, Director 26: Exit hardware and marking shall meet the requirements of the International Fire Code. (IFC Chapter 10) 27: Exits and exit access doors shall be marked by an approved exit sign readily visible from any direction of egress travel. Access to exits shall be marked by readily visible exit signs in cases where the exit or the path of egress travel is not immediately visible to the occupants. Exit sign placement shall be such that no point in an exit access corridor is more than 100 feet (30,480 mm) or the listed viewing distance for the sign, whichever is less, from the nearest visible exit sign. (IFC 1011.1) 28: Every exit sign and directional exit sign shall have plainly legible letters not less than 6 inches (152 mm) high with the principal strokes of the letters not less than 0.75 inch (19.1 mm) wide. The word "EXIT" shall have letters having a width not less than 2 inches (51 mm) wide except the letter "I ", and the minimum spacing between letters shall not be less than 0.375 inch (9.5 mm). Signs larger than the minimum established in section 1011.5.1 of the International Fire Code shall have letter widths, strokes and spacing in proportion to their height. The word "EXIT" shall be in high contrast with the background and shall be clearly discernible when the exit sign illumination means is or is not energized. If an arrow is provided as part of the exit sign, the construction shall be such that the arrow direction cannot be readily changed. (IFC 1011.5.1) 29: Exit signs shall be illuminated at all times. To ensure continued illumination for a duration of not less than 90 minutes in case of primary power loss, the sign illumination means shall be connected to an emergency power system provided from storage batteries, unit equipment or on -site generator. (IFC 1006.1, 1006.2, 1006.3) 30: Means of egress, including the exit discharge, shall be illuminated at all times the building space served by the means of egress is occupied. The means of egress illumination level shall not be less than 1 foot - candle (11 lux) at the floor level. The power supply for the means of egress illumination shall normally be provided by the premise's electrical supply. In event of a power failure an emergency power system shall provide power for a duration of not less than 90 minutes and shall consist of storage batteries, unit equipment or on -site generator. (IFC 1006.1, 1006.2, 1006.3) 31: Maintain sprinkler coverage per N.F.P.A. 13. Addition /relocation of walls, closets or partitions may require relocating and /or adding sprinkler heads. (IFC 901.4) 32: Sprinklers shall be installed under fixed obstructions over 4 feet (1.2 m) wide such as ducts, decks, open grate flooring, cutting tables, shelves and overhead doors. (NFPA 13- 8.6.5.3.3) 33: All new sprinkler systems and all modifications to existing sprinkler systems shall have fire department review and approval of drawings prior to installation or modification. New sprinkler systems and all modifications to sprinkler systems involving more than 50 heads shall have the written approval of the W.S.R.B., Factory Mutual, Industrial Risk Insurers Kemper or any other representative designated and /or recognized by the City of Tukwila, prior to submittal to the Tukwila Fire Prevention Bureau. No sprinkler work shall commence without approved drawings. (City Ordinance #2050) 34: Maintain fire alarm system audibleNisual notification. Addition /relocation of walls or partitions may require relocation and /or addition of audible /visual notification devices. (City Ordinance #2051) 35: All new fire alarm systems or modifications to existing systems shall have the written approval of The Tukwila Fire Prevention Bureau. No work shall commence until a fire department permit has been obtained. (City Ordinance #2051) (IFC 104.2) 36: Contact The Tukwila Fire Prevention Bureau to witness all required inspections and tests. (City Ordinances #2050 and #2051) doc: Conditions D06 -331 Printed: 10 -13 -2006 City of Tukwila Department of Community .Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: rttukwila,wa,uc **continued on next page** Steven M. Mullet, Mayor Steve Lancaster, Director 37: Any overlooked hazardous condition and /or violation of the adopted Fire or Building Codes does not imply approval of such condition or violation. 38: These plans were reviewed by Inspector 511. If you have any questions, please call Tukwila Fire Prevention Bureau at (206)575 -4407. doc: Conditions D06 -331 Printed: 10 -13 -2006 City of Tukwila Signature: AQf / Print Name: Department of Community Development 6300 Southcenter Boulevard, Suite 11100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: ri.tukwila.wa.u8 I hereby certify that I have read these conditions and will comply with them as outlined. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provision of any other work or local laws regulating construction or the performance of work. 1(Ld y. Steven M. Mullet, Mayor Steve Lancaster, Director Date: ( u((2 (2-04 C doc: Conditions D06 -331 Printed: 10-13 -2006 SITE LOCATION CITY OF TUKWILA Community Development Department Public Works Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 httn.11www. ci. tkwila. wa. us Building Permit No. poio- '351 Mechanical Permit No. AAij - I Plumbing/Gas Permit No. 1 I Public Works Permit No. Project No. (For office use only) Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. **Please Print** 4-4445 p King Co Assessor's Tax No.: ,..24.0 1 SAO - 00&o Site Address: - c o. /.54* Pt() et, Suite Number. Floor. Tenet Name: /52'St Th qOh New Tenant: ] Yes ❑..No Property Owners Name: FD'S 01riA, f a.rg. AhYX of -r? 0 10 E.+l r t Prap Inc. Mailing Address: 1510n - .6. E. 3&tL aFrir- # 7(oa, ,(he.Gle ✓tae tuft c18Gi"�(o City Stare Zip CONTACT PERSON Name MA i cC hi Alt Mailing Address: ) 1 D (Intl u, E -Mail Address: dl4ehle Jdh.lt /vtunJi. ( Company Name: [O ?e- J e_lt'm1n/l . Day Telephone: r-a;OW - 7-j 3- gg9 7 Solt I.�A b� q15108 City ZIP Fax Number. A0(49 • 94(p -13,3 O l GENERAL CONTRACTOR INFORMATION - (Contractor Information for Mechanical (pg 4) for Plumbing and Gas Piping (pg 5) ) Mailing Address: City Contact Person. Day Telephone: E -Mail Address: Fax Number. Contractor Registration Number. Expiration Date: City Contact Person: Day Telephone: E -Mail Address: Fax Number. Q:UPpliraiooe\FmnaAppli®tiwe On *rec13-2006 -Pamir Applieadon.dec Revised: 42006 bb State ARCHITECT OF RECORD - All plans must be wet stamped by Architect of Record Company Name: ba U4 t 141-/t..t L- Arch, k d. - Mailing Address: 1 21.2-0 Salem it j 1 r. Ai/ 1k 1 J LD S Nth-, // )/1. 98 t 08 `� City ) Stow Tip Contact Person: a �' l ll- Day Telephone: a.° 0- 4Ag,'Sgq 1 E -Mail Address: d Pt h 12.0 d{ 4ilscri .11, (n n 'J Fax Number. c)%0 lO � 'fp• B && ENGINEER OF RECORD - All plans must be wet stamped by Engineer of Record Company Name: Mailing Address: Zip Stare Zip Page 1 of6 BUILDING PERMIT INFORMATION - 206 -431 -3670 Valuation of Project (contractor's bid price): $ j 0 vide detailed information): r bageib. (.nnhkruck A lion -bean Scope of Work (please a ba.kcr(j VC--h b 3 G Q: AapliwtioMFanwppplicaimu Online U -2006 - Pe n It Applcelion.doc amisod: 4206 bh v Inbtttl 4 Existing Building Valuation: $ • I . A l o I! •IC I. • / itr' 1 �.. �► it '4 6.1 Pith hand amp o chap go -I-o bul:ALAg cnu-e2op - or IIgh4►n'. Will there be new rack storage? ❑..Yes %..No (If yes, a separate permit and plan submittal will be required) Provide All Building Areas in Square Footage Below PLANNING DIVISION: Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) For an Accessory dwelling, provide the following: Lot Area (sq ft): Floor area of principal dwelling: Floor area for accessory dwelling: 'Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard: Compact: Handicap: Will there be a change in use? El ....Yes ❑..No If "yes ", explain: FIRE PROTECTION/HAZARDOUS MATERIALS: )4. Sprinklers ❑..Automatic Fire Alarm 0.. None ❑ ..Other (specify) Will there be storage or use of flammable, combustible or hazardous materials in the building? 0.. Yes ❑.. No If "yes", attach list of material• and storage locations on a separate R -1/2 x 11 paper indicating quantities and Material Safety Data Sheets. SEPTIC SYSTEM: ❑ On -site Septic System — For on -site septic system, provide 2 copies of a current septic design approved by King County Health Department. Page 2 of 6 PUBLIC WORKS PERMIT INFORMATION — 206- 433 -0179 Scope of Work (please provide detailed information): Water District ...Tukwila ❑...Water District 4125 ❑ ...Water Availability Provided Sewer District ❑...Tukwila ❑ ...Sewer Use Certificate Please refer to Public Works Bulletin #1 for fees and estimate sheet. Cr. Va1Vue Snbmitted with Annitcatlon ( mark boxes which : ❑ ...Civil Plans (Maxim® Paper Size - 22" 134") ❑ ...Technical Information Report (Storm Drainage) ❑ ...Bond ❑ .. Insurance ❑ .. Easement(s) Proposed Activities (mark boxes that apply): ❑ ...Right -of -way Use - Nonprofit for less than 72 hours ❑ ...Right-of-way Use - No Disturbance ❑ ...Construction/Excavation/Fill - Right-of-way Non Right -of -way ❑ ...Total Cut cubic yards ❑ ...Total Fill cubic yards Can before you Dig: 1400- 424-5555 ❑ .. Highline ❑ .. Geotechnical Report ❑ .. Maintenance Agreement(s) ❑ .. Renton ❑..Renton ❑..Seattle ❑...Sewer Availability Provided ❑ .. Approved Septic Plans Provided ❑ .. Right-of-way Use - Profit for less than 72 hours ❑ .. Right -of -way Use - Potential Disturbance ❑ .. Work in Flood Zone ❑ .. Storm Drainage ❑...Traffc Impact Analysis ❑...Hold Harmless - (SAO) ❑...Hold Harmless - (ROW) ❑...Sanitary Side Sewer ❑ .. Abandon Septic Tank ❑ .. Grease Interceptor ❑...Cap or Remove Utilities ❑ .. Curb Cut ❑ .. Chamelization ❑ ...Frontage Improvements ❑ .. Pavement Cut ❑ .. Trench Excavation ❑ ...Traffic Control ❑ .. Looped Fire Line ❑ .. Utility Undergrounding ❑ ...Backtlow Prevention - Fire Pmtection " Irrigation Domestic Water " ❑...Permanent Water Meter Size... ❑ ...Temporary Water Meter Size .. ❑...Water Only Meter Size ❑ ...Sewer Main Extension. Public _ Private ❑ ...Water Main Extension Public _ Private FINANCE OJFO Fire Line Size at Property Line Number of Public Fire Hydrant(s) ❑...Water ❑...Sewer ❑...Sewage Treatment Monthly Service Billin Name: Day Telephone: Mailing Address: City State tip Water Meter Refund/Billing: Name: Day Telephone: Mailing Address City State Lp Q: W1ricuionacansMMicaioes On line \3 -2006 - Remit ApplicaS Aoc Faired: 42106 bh ❑ ...Deduct Water Meter Size ........ Page 3 of 6 Unit Type: Qty Unit Type: Qty Unit Type: Qty Boiler /Compressor: Qty Fwnace<100K BTU Air Handling Unit >10,000 CFM Fire Damper 0-3 1IP /100,000 BTU Furnace >100K BTU Evaporator Cooler Diffuser 3 -151iP /500,000 BTU Floor Furnace Ventilation Fan Connected to Single Duct Thermostat 15-30 HP /1,000,000 BTU Suspended/Wall/Floor Mounted Heater Ventilation System Wood/Gas Stove 30.50 HP /1,750,000 BTU Appliance Vent Hood and Duct mid Water Heater 50+HP/1,750,000 BTU Repair or Addition to Heat/Refiig/Cooling System Incinerator - Domestic Emergency Generator Air Handling Unit <10,000 CFM Incinerator — Comm/Ind Other Mechanical Equipment N�P MECHANICAL PERMIT INFORMATION - 206-431 -3670 MECHANICAL CONTRACTOR INFORMATION Company Name: I VV Mailing Address: City State Zip Contact Person: Day Telephone: E -Mail Address: Fax Number: Contractor Registration Number. Expiration Date: Valuation of Project (contractor's bid price): $ I �7i 4 il '7D • GD Scope of Work (please provide detailed information): At %d _411' W1 14 N. -• ust ,'t , , se Residential: New .... ❑ Replacement .... ❑ Commercial: New .... ❑ Replacement .... ❑ Fuel Tyne: Electric ❑ Gas ....g Other. Indicate type of mechanical work being installed and the quantity below: Q:Utpicationa\Fonna- Ap,1icalaa On U, 3 -2O6- Pamit Apalicanondoc Revised: 1 bb Nth, 1fltef dean— Page 4 of 6 Fixture Type: Qty Fixture Type: Qty Fixture Type: Qty Fixture Type: Qty Bathtub or combination bath/shower Drinking fountain or water cooler (per head) Wash fountain Gas piping outlets ' Bidet Food -waste grinder, commercial Receptor, indirect waste Clothes washer, domestic Floor drain Sinks 2 Dental unit, cuspidor Shower, single head trap Urinals Dishwasher, domestic, with independent drain Lavatory Water Closet Building sewer or trailer park sewer Rain water system — per drain (inside building) Water heater and/or vent Industrial waste pretreatment interceptor, including its trap and vent, except for kitchen type grease interceptors Repair or alteration of water piping and/or water treating equipment Repair or alteration of drainage or vent piping Medical gas piping system serving one to five inlets/outlets for specific _gas Additional medical gas inlets/outlets — six or more __- -1 PLUMBING AND GAS PIPING PERMIT INFORMATION - 206 -431 -3670 PLUMBING AND GAS PIPING CONTRACTOR INFORMATION Company Name: Mailing Address City Stare Zip Contact Person: Day Telephone: E -Mail Address: Fax Number. Contractor Registration Number. Expiration Date: Valuation of Project (contractor's bid price): $ f 1j ?4 2 • CO �j•_ Scope of Work (please provide detailed information): • GI. x140 et4 . l4ub - W NEM (VA) T t L # •/4 •r 4.. Indicate type of plumbing fixtures and/or gas piping outlets being installed and the quantity below: Q:■ApcationsTamwAppliratiaa On Una U -2006 - Palau Applicaion.doc Reviled: 4-2006 bb 1 [Ili 14 s.P Page 5 of 6 PERMIT APPLICATION NOTES — Applicable to all permits in this application Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. Building and Mechanical Permit The Building Official may gram one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.32 International Building Cade (current edition). Plumbing Permit The Building Official may grant one extension of time for an additional period not exceeding 180 days. The extension shall be requested in writing and justifiable cause demonstrated. Section 103.4.3 Uniform Plumbing code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDINGO i'RO ry •RIZEDAGENT: et Signature: \ �� L$ Date: t ,,ee4J I Day Telephone: Ot 0 0 - "7"& 5997 Mailing Address: L--):1,-)-0 elatetva-i bri -c, .ho. ,c, f., WA. °18 1(08 Cuy Stare Zip Print Name: - Datki d. / JJ y Date Application Expires: 2 -lib -0 Date Application Accepted 0'31 -oll Q:U(Miwiom cemr.Apaliwioas OnUi.c3.3(16- Permit Appliicatttion.doc Revised: 4206 6h Staff Page 6 of 6 City of Tukwila 6300 Southcenter BL, Suite 100 / Tukwila, WA 98188 / (206) 431 -3670 Parcel No.: 2613200086 Address' 4445 S 134 PL TUKW Suite No: Applicant: BEST BAGELS Payee: BEST BAGELS INC TRANSACTION LIST: Type Method Description Amount ACCOUNT ITEM LIST: Description Current Pmts BUILDING - NONRES STATE BUILDING SURCHARGE RECEIPT Payment Check 2852 229.08 Account Code 000/322.100 224.58 000/386.904 4.50 Permit Number: D06 -331 Status: APPROVED Applied Date: 08/31/2006 Issue Date: Receipt No.: R06 -01625 Payment Amount: 229.08 Initials: BLH Payment Date: 10/13/2006 09:07 AM User ID: ADMIN Balance: $0.00 Total: 229.08 0723 10/13 9716 TOTAL 337.08 doc: Receipt Printed: 10 -13 -2006 City of Tukwila 6300 Southcenter BL, Suite 100 / Tukwila, WA 98188 / (206) 431 -3670 Parcel No.: 2613200086 Address: 4445 S 134 PL TUKW Suite No: Applicant: BEST BAGELS RECEIPT Receipt No.: R06 -01375 Payment Amount: 145.98 Initials: BLH Payment Date: 08/3112006 03:42 PM User ID: ADMIN Balance: $229.08 Payee: DAVID E. KEHLE ARCHITECT TRANSACTION UST: Type Method Description Amount Payment Check 17493 145.98 ACCOUNT ITEM UST: Description Current Pmts PLAN CHECK - NONRES Account Code 000/345.830 145.98 Permit Number D06 -331 Status: PENDING Applied Date: 08/31/2006 Issue Date: Total: 145.98 9234 09/01 9716 TOTAL 234.73 doc: Receipt - Printed: 08 -31 -2006 Pro � e 'A ■ Type °ri NA-n.I \.. Address: L) y Li-sr S 3y pi Date Called: ji Special Instructions: bate Wanted: I - 1 p - 0 —7 a.m p.m. Requester: Phone No: r I INSPECTION RECORD I I Retain a copy with permit INSPE ON NO. PE CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)f)31.3 1Sk eproved per applicable codes. COMMENTS: G-C Date: (- / b- 0"7 REINSPECTION FEE R QUIRED. Pr ? to inspection, fee must be t 6300 Southcenter Blv ., Suite 100. Call to sechedule reinspection. Receipt No.: 'Date: El Corrections required prior to approval. Project n LL fC s 1 8 !'3cz 4; Type of nspectiioiT '/' ` Address: - L / Ili/ 5C /3 V f/ Date Called: Special Instructions: Date Wanted: 1 " 7 — O C a. m'` p.m. Requester: Phone No: ` p / aOG -1&85 -a( 7 INSPECTION NO. INSPECTION RECORD Retain a copy with permit CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 �+ , (20¢)431 -36X0 COMINENTS: / 6 /9sO ,7 s A/4- Approved per applicable codes. D Corrections required prior to approval, Date: / r 7.96 rl $58.00 REINSPECTION FEE R IRED. Prior tcc spection, fee must be paid at 6300 Southcenter Blvd„ Suite 100. Call to sechedule reinspection. Receipt No.: Date: Project: OS PS-/ 4.9 6e r / S Type of Inspection: / ✓PAS • 4 U Address: 1 7 L- R/ 5 5 /3" ,7 C Date Called: Special Instructions: Date Wanted: / /b — Z. 7 - V l.. a. .m P.m. Requester: Phone No: 20 6r 633 -0 637 INSPECTION RECORD Retain a copy with permit INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3 COMMENTS: l )Plcr G71 tr, - /491/0C �r 2) rk eti 1/ / s , // Inspector: JDate�� El Approved per applicable codes. $58.00 REINSPECTION FE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to sechedule reinspection. (Receipt No.: Corrections required prior to approval. Date: S � 6 - 33 / PERMIT NO. 0 COMMENTS: Type of Infection: /l r e.0 Y // c_ AEc-N lin� A7/ SeIA Address: Lit-it-i5 S . 1 34 PL. iflcc1 /?i:'ant 11101c 2S`l - .�wn -i LOX Suite #: in .e�� Special Instructions: !1/1 - 2-00 — A N 4z 01/ a O 6ie3 - j637 /r N I•.- _ ✓ Alaur/b✓ /iv& fin it t- #Lfl). 1 El L) 4 Ant- 13.0. 47 17" Project: S nm c ``1 E> EZ 13At -At ��A &'» Type of Infection: /l r e.0 Y // c_ AEc-N lin� A7/ SeIA Address: Lit-it-i5 S . 1 34 PL. Contact Person: Suite #: 4124A/ .e�� Special Instructions: Phone No.: a O 6ie3 - j637 Needs Shift Inspection: Mwe CO • / Sprinklers: y Fire Alarm: Hood & Duct: E/ Monitor: Apt Pre -Fire: MK Permits: -W) Occupancy Type: 2 INSPECTION NUMBER pproved per applicable codes. Word /Inspection Record Form.Doc INSPECTION RECORD Retain a copy with permit CITY OF TUKWILA FIRE DEPARTMENT ila, Wa. 98188 206 - 575 -4407 n Corrections required prior to approval. Date: 0 O /a PERMIT NUMBERS H rs.: Inspector: 9 $80.00 REINSPECTION FEE REQUIRED. You will receive an invoice from the City of Tukwila Finance Department. Call to schedule a reinspection. 1/13/06 T.F.D. Form F.P. 113 Project Info Project Address BEST aAGete Date 8/30/2006 4445 S. 134TH PLACE For Building Department Use �� EZ E con {, Ths TUIGIILA, WASHINGTON Applicant Name: David Kehl. Architect Applicant Address: 12720 Gateway Drive, Suite 116, Seattle, WA 98168 ^ Applicant Phone: 206- 433 -8997 (c }♦ !G No. Project Description ❑ New Building ❑ Addition IJ Alteration Refer to WSEC Section 1513 for controls and commissioning ❑ PlarisIrtdtlded . reguiretnents. Compliance Option C) Prescriptive 0 Lighting Power Allowance 0 Systems Analysis (See Qualification Checklist (over). Indicate Prescriptive & LPA spaces cleani on plans.) Alteration Exceptions (check appropriate box - sec. 1132.3) ❑ No changes are being made to the fighting ./ Less than 80% of the fixtures new, installed wattage not increased, & space use not changed. 0.2 W/ft Location KCVICVVLV 1 'J1" CODE €OMPlIANCE Allowed Watts per 1t " Allowed Watts per ft or per If Area in ft (or If for perimeter) Allowed Watts x ft (or x lt) Covered Parking (standard paint) . nnafl'ICO 38.0 0.2 W/ft Ate 3 1 MIK Covered Palling (reflective paint) p� 12 2006 0.3 W /tt PEE.MIT CFNTEF Open Parking ^ 0.2 W/ft "'From Table 15-1 (over) - document all exceptions on form LTG-LPA Total Allowed Watts 30.4 Outdoor Areas 1 ( 7 � , 0 2 yy/ft Bldg. (by facade) U. O t UkwilG 0.25 we Bldg. (by perim)' BUILD1Nta DIVISION 7.5 W /If Location (floor /room no.) Occupancy Description Allowed Watts per 1t " Area in ft Allowed x Area vssrxauLa Catt4ar AREA 0.80 38.0 30.4 Ate 3 1 MIK PEE.MIT CFNTEF "'From Table 15-1 (over) - document all exceptions on form LTG-LPA Total Allowed Watts 30.4 Location (floor /room no.) Fixture Description Number of Fixtures Watts/ Fixture Watts Proposed VESTIBULE 6" SWUM= MOUNT CawACT nOORESENr 1 25.0 25,0 Ate 3 1 MIK PEE.MIT CFNTEF Total Proposed Watts may not exceed Total Allowed Watts for Interior Total Proposed Watts 25 , 0 Location Fixture Description Number of Fixtures Watts/ t`1 a8� Fixture 3E - ,I i Ifi Ate 3 1 MIK PEE.MIT CFNTEF 2004 Washington State Nonresidential Energy Code Compliance Form Lighting Summary LTG -SUM 2004 Washington State Nomaidential Energy Coos Compliance Farms Maximum Allowed Lighting Wattage (Interior Proposed Lighting Wattage (Interior) Revised Mw 2005 Notes: 1. Use manufacturer's listed maximum input wattage. For hard -wired ballasts only, the default table in the NREC Technical Reference Manual may also be used 2. Include exit lights unless less than 5 watts per fixture. 3. List all fixtures. For exempt lighting, not exception and leave Watts/Fixture blank. Maximum Allowed Li 1. Choose either the facade area or the perimeter method, but not both) Total Allowed Watts Use mtgr fisted maximum input wattage. For tortures with ham - Only, the default table in the NREC Technical Reference Manual may also be used. Proposed Lighting Wattage (Exterior) Total Proposed Watts may not exceed Total Allowed Watts for Exterior Total Proposed Watts "P 351 Use' LPA`(W /sf) Use' LPA`(W /sf) Painting, welding, carpentry, machine shops 2.3 Office buildings, office/administrative areas in facilities of other use types (including but not limited to schools hospitals, institutions, museums, banks, churches) ' ' 1.0 Barber shops, beauty shops 2.0 Police and fire stations 1.0 Hotel banquet/conference/exhibition hall" 2.0 Atria (atriums) 1.0 Laboratories 1.8 Assembly spaces', auditoriums, gymnasia heaters 1.0 Aircraft repair hangars 1.5 Group R -1 common areas 1.0 Cafeterias, fast food establishments' 1.5 Process plants 1.0 Factories, workshops, handlincLareas 1.5 Restaurants/bars' 1.0 Gas stations, auto repair shops 1.5 Locker and/or shower facilities 0.8 institutions 1.5 Warehouses ", storage areas 0.5 Libraries 1.5 Aircraft storage hangars 0.4 Nursing homes and hotel/motel quest rooms 1.5 Retail' retail banking 1.5 Wholesale stores (pallet rack shelving) 1.5 Parking garages (see exterior lighting) Section 1532 Mali concourses 1.4 Schools buildings (Group E occupancy only), school classrooms, day care centers 1.35 Plans Submitted for Common Areas Only' Laundries 1.2 Main floor building lobbies' (except mall concourses) 1.2 Medical Offices, Clinics" 1.2 Common areas, corridors, toilet facilities and washrooms, elevator lobbies 0.8 Prescriptive Spaces Occupancy: 0 Warehouses, storage areas or aircraft storage hangers 0 Other Qualification Checklist Lighting Check if all fixtures are ballasted and at least 95 %' of fixtures are either. Note: If occupancy type is 'Other and fixture Figures: answer is cheated, the number of fixtures in (Section 1. Fluorescent fixtures which a) are non - lensed. b) have 1 or 2 two lamps c) have the space is not limited by Code. Cleary 1521) 5-60 watt T-1, T -2, T -4, T -5, T .6, T-8 lamps. d) have hard -wired electronic indicate these spaces on plans. If not dimming ballasts. Screw -in compact fluorescent fixtures do not qualify. qualified, do LPA Calculations. 2. Metal Halide with a) reflector b) ceramic MH lamps <= 150w c) electronic ballasts ' - Exit and LED lights can be excluded from count if < 5 watts/fixture. 2004 Washington State Nonresidential Energy Code Compliance Form Lighting Summary (back) LTG -SUM 2009 Waanirglon State al Energy Code Compliance Gams TABLE 15 -1 Unit Lighting Power Allowance (LPA Revised May 2005 Footnotes for Table 15 -1 1) In cases in which a general use and a specific use are listed, the specific use shall apply. In cases in which a use is not mentioned specifically, the Unit Power Allowance shall be determined by the building official. This determination shall be based upon the most comparable use specified in the table. See Section 1512 for exempt areas. 2) The watts per square foot may be increased, by two percent per foot of ceiling height above twenty feet, unless specifically directed otherwise by subsequent footnotes. 3) Watts per square foot of room may be increased by two percent per foot of ceiling height above twelve feet. 4) For all other spaces, such as seating and common areas, use the Unit Light Power Allowance for assembly. 5) Watts per square foot of room may be increased by two percent per foot of ceiling height above nine feet. 6) See Section 1532 for exterior lighting. 7) For conference rooms and offices less than 1 50h with full height partitions, a Unit Lighting Power Allowance of 1.20 w/ft may be used. 8) For the fire engine room, the Unit Lighting Power Allowance is 1.0 watts per square foot. 9) For indoor sport tournament courts with adjacent spectator seating, the Unit Lighting Power Allowance for the court area is 2.6 watts per square foot. 10) Display window illumination installed within 2 feet of the window, provided that the display window is separated from the retail space by walls or at least three - quarter- height partitions (transparent or opaque). and lighting for free - standing display where the lighting moves with the display are exempt. An additional 1.5 w/ft of merchandise display luminaires are exempt provided that they comply with all three of the following: a) located on ceiling- mounted track or directly on or recessed into the ceiling itself (not on the wall). b) adjustable in both the horizontal and vertical axes (vertical axis only is acceptable for fluorescent and other fixtures with two points of track attachment). c) fitted with LED, tungsten halogen, fluorescent, or high intensity discharge lamps This additional lighting power is allowed only if the lighting is actually installed. 11) Provided that a floor plan, indicating rack location and height, is submitted, the square footage for a warehouse may be defined, for computing the interior Unit Lighting Power Allowance, as the floor area not covered by racks plus the vertical face area (access side only) of the racks. The height allowance defined in footnote 2 applies only to the floor area not covered by racks. 12) .Medical and clinical offices include those facilities which, although not providing overnight patient care, do provide medical, dental, or psychological examination and treatment. These spaces include, but are not limited to , laboratories and treatment centers. 2004 Washin on State Nonresidential Ene Code ComrHance Form Lighting Permit Plans Checklist 2004 Washington State Nonresidential Energy Code Compliance Forms LTG -CHK Revised May 2005 Lighting - General Requirements 1513 Lighting Controls. Lighting, including exempt lighting in Section 1512, shall comply with this section. Where occupancy sensors are cited, they shall have the features listed in Section 1513.8.1. Where automatic time switches are cited, they shalt have the features listed in Section 1513.6.2. 1513.1 Local Control and Accessibility: Each space, enclosed by walls or ceiling- height partitions, shall be provided with lighting controls located within that space. The lighting controls, whether one or more, shall be capable of fuming off all lights within the space. The controls shall be readily accessible, at the point of entry /exit, to personnel occupying or using the space. EXCEPTIONS: The following lighting controls may be centralized in remote locations: 1. Lighting controls for spaces which must be used as a whole. 2. Automatic controls. 3. Controls requiring trained operators. 4. Controls for safety hazards and security. 1513.2 Area Controls: The maximum lighting power that may be controlled from a single switch or automatic control shall not exceed that which Is provided by a twenty ampere circuit loaded to not more than eighty percent. A master control may be installed provided the individual switches retain their capability to function Independently. Circuit breakers may not be used as the sole means of switching. EXCEPTIONS: 1. Industrial or manufacturing process areas, as may be required for production. 2. Areas less than five percent of footprint for footprints over 100,000 square feet. 1513.3 Daylight Zone Control: All dayllghted zones, as defined in Chapter 2, both under overhead glazing and adjacent to vertical glazing, shall be provided with individual controls, or daylight-or occupant- sensing automatic controls, which control the lights Independent of general area lighting. Contiguous daylight zones adjacent to vertical glazing are allowed to be controlled by a single controlling device provided that they do not include zones facing more than two adjacent cardinal orientations (i.e. north, east, south. west). Daylight zones under overhead glazing more than 15 feet from the perimeter shall be controlled separately from daylight zones adjacent to vertical glazing. EXCEPTION: Daylight spaces enclosed by walls or ceiling height partitions and containing 2 or fewer light fixtures are not required to have a separate switch for general area lighting. 1513.4 Display, Exhibition, and Specialty Lighting Controls: All display, exhibition, or specialty lighting shall be controlled independently of general area lighting. 1513.5 Automatic Shut -Off Controls, Exterior. Exterior lighting not Intended for 24 -hour continuous use shall be automatically switched by timer, photocell, or a combination of timer and photocell. Automatic time switches must also have program back -up capabilities, which prevent the loss of program and time settings for at least 10 hours, if power is interrupted. 1513.6 Automatic Shut -Off Controls, Interior, Buildings greater than 5,000 sq, ff. and all school classrooms shall be equipped with separate automatic controls to shut off the lighting during unoccupied hours. Within these buildings, all office areas less than 300f1` enclosed by walls or ceiling- height partitions, and all meeting and conference rooms, and all school classrooms, shall be equipped with occupancy sensors that comply Section 1513.8.1. For other spaces, automatic controls may be an occupancy sensor, time switch, or other device capable of automatically shutting off lighting. EXCEPTIONS: 1. Areas that must be continuously illuminated (e.g., 24 - hour convenience stores), or illuminated in a manner requiring manual operation of the lighting. 2. Emergency lighting systems. 3. Switching for industrial or manufacturing process facilities as may be required for production. 4. Hospitals and laboratory spaces 5. Areas in which medical or dental tasks are performed are exempt from the occupancy sensor requirement. 1513.6.1 Occupancy Sensors: Occupancy sensors shall be capable of automatically tuming off all the lights in an area, no more than 30 minutes after the area has been vacated. tight fixtures controlled by occupancy sensors shall have a wall - mounted, manual switch capable of turning off lights when the space is occupied. 1513.6.2 Automatic Time Switches: Automatic time switches shall have a minimum 7 day dock and be capable of being set for 7 different day types per week and incorporate an automatic holiday "shut -off' feature, which tums off all loads for at least 24 hours and then resumes normally scheduled operations. Automatic time switches shall also have program back -up capabilities, which prevent the loss of program and time settings for at least 10 hours, if power is interrupted. Automatic time switches shall incorporate an over -ride switching device which: a) is readily accessible; b) is located so that a person using the device can see the lights or the areas controlled by the switch, or so that the area being illuminated is annunciated; and c) is manually operated; d) allows the lighting to remain on for no more than two hours when an over -ride is initiated; and e) controls an area not exceeding 5,000 square feet or 5 percent of footprint for footprints over 100,000 square feet, whichever is greater. 1513.7 Commissioning Requirements: For lighting controls which include daylight or occupant sensing automatic controls, automatic shut-off controls, occupancy sensors, or automatic time switches, the lighting controls shall be tested to ensure that control devices, components, equipment and systems are calibrated. adjusted and operate In accordance with approved plans and specifications. Sequences of operation shall be functionally tested to ensure they operate in accordance with approved plans and specifications. A complete report of test procedures and results shall be prepared and filed with the owner. Drawing notes shall require commissioning In accordance with this paragraph. Lighting Permit Plans Checklist LTG -CHK 2004 Washington Stare Nonresidential Energy Cone Compliance ROM Reuieea May 200.5 Project Address BEST BAGELS (Date 8/30/2006 The following information is necessary to check a lighting pemtit application for compliance with the lighting requirements in the 2004 Washing on State Nonresidential Energy Code. Applicability (yes, no, n.a.) Code Section Component Information Required Location on Plans Building Department Notes LIGHTING CONTROLS (Section 1513) yes 1513.1 Local control/access Schedule with type, indicate locations T -1 yea 1513.2 Area controls Maximum limit per switch T_1 n. a. 1513.3 Daylight zone control Schedule with type and features, indicate locations n. a. vertical glazing Indicate vertical glazing on plans n. a. overhead glazing Indicate overhead glazing on plans n. a. 1513.4 Display /exhib/special Indicate separate controls 1513.5 Exterior shut -off Schedule with type and features, indicate location a. a. (a) timer w/backup Indicate location a.a. (b) photocell. Indicate location 1513.6 Inter. auto shut -off Indicate location n. a. 1513.6.1 (a) occup. sensors Schedule with type and locations n. a. 1513.6.2 (b) auto. switches Schedule with type and features (back -up, override capability); Indicate size of zone on plans a. a. 1513.7 Commissioning Indicate requirements for lighting controls commissioning yes Lighting Sum. Form Completed and attached. Schedule with fixture types, (amps, ballasts, watts per fixture n. a. 1437 Elec motor efficiency MECH -MOT or Equipment Schedule with hp, rpm, efficiency 2004 Washington State Nonresidential Energy Code Compliance Form If "n o" Is circled for any question, provide explanation: Space Heat Type 0 Electric resistance C) All other (see over for definitions) Glazing Area Calculation Note: Below grade walls may be included in the Gross Exterior Wall Area if they are insulated to the level required for opaque wails. Total Glazing Area Electronic version: these values are automatically taken from ENV -UA -1. (rough opening) Gross Exterior (vertical & overhd) divided by Wall Area times 100 equals % Glazing T X 100 = Concrete/Masonry Option 0 Yee Check here if using this option and if project meets all requirements for the Concrete/Masonry Option. See Decision Flowchart (over) for qualifications. Enter requirements for each qualifying 0 no assembly below. Project Info Project Address ease 711r"41 q Date 8/30/2006 445 S. 134TH PLACE For Building Department Use TDaILA, WASHINGTON Applicant Name: David Wahl* Architect Applicant Address: 12720 Gateway Drive, Suite 116, Seattle, WA 98168 Applicant Phone: 206- 433 -8997 2004 Washington State Nonresidential Energy Code Compliance Form Envelope Summary Climate Zone 1 ENV -SUM 2004 Washington State Nonresidential Energy Code Compliance Farms Revised May 2005 Project Description ❑ New Building ❑ Addition 0 Alteration ❑ Change of Use Compliance Option 0 Prescriptive ❑ Component Performance (See Decision Flowchart (over) for qualifications) ❑ Systems Analysis Envelope Requirements (enter values as applicable) Fullyheated/cooled space Minimum Insulation R- values Roofs Over Attic All Other Roofs Opaque Walls Below Grade Walls Floors Over Unconditioned Space Slabs-on-Grade Radiant Floors Opaque Doors Vertical Glazing Overhead Glazing Maximum U- factors Maximum SHGC (or SC) Vertical/Overhead Glazing Semi - heated space 2 Minimum Insulation R- values Roofs Over Semi - Heated Spaces 1. Assemblies with metal framing must comply with overall U- factors 2. Refer to Section 1310 for qualifications and requirements Notes: No change to envelope. Opaque Concrete/Masonry Wall Requirements Wall Maximum U -factor is 0.15 (R5.7 continuous ins) CMU block walls with insulated cores comply If project qualifies for Concrete /Masonry Option, list walls with HC 2 9.0 Btu/ft below (other walls must meet Opaque Wall requirements). Use descriptions and values from Table 10-9 in the Code. Wall Description (including insulation R -value & position) U- factor 2004 Washington State Nonresidential Energy Cods Compliance Forms 1302 Space Hest Type: For to papose of delamti um building envelope requirements, the following two categories comprise all space heating types: Other. MI other space heating systems including gas solid fuel, oil, and propane space heating systems and those systems listed in the exception to elearie resistance. (continued M nght) Concrete/Masonry Opti Assembly Description • Mass Wall Insulation Req. Mass Wall U0.15/R5.7ci CMU Block Ins. Cores Wood Frame R19 Metal Framed R19 2004 Washington State Nonresidential Energy Code Compliance Form Envelope Summary (back) Climate Zone 1 ENV -SUM Decision Flowchart for Prescriptive Option Use this flowchart to determine if project qualifies for the optional Prescriptive Option. If not, either the Component Performance or Systems Analysis Options must be used. All Insulation Installed? Below Grd Wall (ext) Below Grd Wall (oth) Roof OverAtgc All Other Roof Raised Floor Slab-On -Grade Radiant Floor Opaque Door R -10 R -19 R -30 R -21 R -19 R -10 R -10 U -0.80 of L Yes Y es • Glazing Criteria Met? Glazing Area % 0-30% 30-45% >45% Vert OH UVal UVal 0.55 0.70 0.45 0.80 Not Allowed SHGC 0.45 0.40 Assy.Tag Yes ti Glazing Area% 0-30% >30 Prescriptive Path Allowed ` Yes Component Performance or - Systems Analysis Required Yes Ye Vert OH UVal UVal SHGC 0.40 0.80 0.40 Not Allowed No Wall Heat Capacity (HC) HC Totals Area weighted NC: divide total of (HC x area) by Total Area Revised May 2005 Bauble Resistance. Space heating systems which use electric resistance elements as the primer" Mating system including baseboard, radiant, and faced air alas where the total electric resistance heat capacity exceeds 1.0 WM of the gross conditioned floor area. Exception: Heat pumps and terminal electric resistance heating in variable air volume distribution systems. 5 f All Insulation Installed? Below Grd Wall (ext) Below Grd Wag (oth) Roof Over Attic All Other Roof Raised Floor Slab-On -Grade Radiant Floor Opaque Door Wood R -10 R -19 R-38 R-30 R-30 R -10 R -10 U -0.80 Metal R -10 U -0.082 U -0.031 U -0.034 U -0.029 R -10 R -10 U -0,80 Area (sf) Yes— Mass Wall Insulation Req. Mass Wall U0.15/R5.7ci CMU Block Ins. Cores Wood Frame R19 Metal Framed U0.062 HCxArea 9f the area weighted heat capacity (HC) of the total above grade wall is a minimum of 9.0, the Concrete Masonry Option may be used. For framed walls, assume HC 0 unless calculations are provided; for all other walls, use Section 1009. ACTIVITY NUMBER: D06 -331 DATE: 08 -31 -06 PROJECT NAME: BEST BAGELS SITE ADDRESS: 4445 S 134 PL X Original Plan Submittal Response to Incomplete Letter # Response to Correction Letter # Revision # After Permit Issued DEPARTMENTS: r B idngDivin Public Works Complete Comments: PLAN REVIEW /ROUTING SLIP TUES/THURS ROUTING: Please Route R Structural Review Required REVIEWER'S INITIALS: APPROVALS OR CORRECTIONS: Approved ❑ Notation: REVIEWER'S INITIALS: Documents/routing slip.doc 2 -28 -02 'QERMIT COORD COPY �-- Approved with Conditions 6/ kw , q- 04fr Fire Prevention Structural DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Incomplete ❑ 3M 4? q-iz - Plaining Division L[ I Permit Coordinator PQ DUE DATE: 09-05-06 Not Applicable ❑ Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: No further Review Required DATE: DUE DATE: 10-03-06 Not Approved (attach comments) ❑ DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: Kind of Fixture Flatur Units No. of Fixtures Total Fixture (Mks Puak Pilvate Public Private Bathtub and Shower 4 4 Shower, per head 2 2 Dishwasher 2 2 Drinking fountain (each head) 1 .5 Hose bibb (Interior) 2.5 2.5 I la, Clotheswasher or laundry tub 4 2 Sink, bar or lavatory 2 1 2. '2 Sink, Clinic flushing 8 8 Sink, kitchen 3 2 I t t Sink, dher (service) 3 1.5 Sink, wash fountain, drde spray 4 3 Urinal, flush valve,1 GPF 5 2 Urinal, flush valve, >1 GPF 6 2 Water closet, tank or valve, 1.6 GPF 6 3 Water doset, tank or valve, >1.6 GPF 8 4 Non- Residential Sewer Use Certification (To be completed for all new sewer connections, reconnections or change of use of existing connections. This form does not apply to repairs or replacements of existing sewer connections within five years of disconnect.) Pursuant to King County Code 28.84, all sewer customers who establish a new sewer customers. The charge is collected semi- annually. All future new service which uses metropolitan sewage facilities shall be subject to a billings can be prepaid at a discounted amount. capacity charge. The amount of the charge Is established annually by the King County Council at a rate per month per residential customer or residential customer equivalent for a period of fifteen years. The purpose of the charge is to recover costs of providing sewage treatment capacity for / Mum print Of lype) 66O p ort d .�1xsWi.S 't A.Yi.� /� L � Owner's Name twbdivisioo.Name e l o 6 4m � p 4 !b Subdiv. K Block M Building Name (if applicable) Properly Street Address 1 4- 4 -1--k5 -k5 - Raced City, State ZI P Owner's Phone Number 42S * /YT Phon ( ) Owner's Mailing Address (if different from above) I5)DO- 5i=. AS t!' 4Fvrr# #' 1(09, &&-ells, toA . cl acbto A. Fixture Units Fixture Units x Number of Fixtures = Total Fixture Units Total No. of Fixture Units _ 20 1058 (Rev. 1/03) l �l/...cc . -r O - ! I Total Fixture Units ki S Residential Customer Equivalent (ACE) 20 fixture units equal 1.0 RCE Oe3Z RCE White — King County Department of Natural Resources and Parks K CoulRY W Questions regarding the capacity charge or this form should be referred to King County's Wastewater Treatment Division at (206) 684 -1740. Property Tax ID d. L013an nog Party to be Billed (if different from owner) Part's Mailing Address: City or Sewer District III rib 1HP' Date of Connection Side Sewer Permit 1f 'S IM I Ifs or Property Contact Phone e ( Demolition of pre - existing building? ❑ Yes 0 No Type of building demolished Sewer disconnect date B. Other Wastewater Flow (in addition to Fixture Units identified in Section A) Type of Facility /Process: Estimated Wastewater Discharge: 1M Gallons/days Residential Customer Equivalents (RCE): 187 gallons per day equals 1.0 RCE C. Total Residential Customer Equivalents: (add A & B) A B Total Discharge (gaVday) __ 1 87 a•3Zt 1 RCE 1 RCE RECEIVED art OFTItKWILP AUG 3 1 2006 PERMIT CENTER I certify that the information gi?en is Corr €ct. I unde1 to that the capacity charge levied will be based on this information and any deviation will require resubmission of corrected data for determination of a revised capacity charge. Signature of Owner/ Representative Print Name of Owner/ el Representative iq Date e kYg Yellow — Local Sewer Agency Pink — Sewer Customer .®,s. CITY OF TUKWILA Community Development Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 Permit Center/Building Division: 206 -431 -3670 Public Works Department: 206 - 433 -0179 Planning Division: 206 -431 -3670 STATE OF WASHINGTON) ) ss. COUNTY OF KING ) AFFIDAVIT IN LIEU OF CONTRACTOR REGISTRATION itoohliN s, - nK.&t ma 0 [please print] 1. I have made application for a building permit from the City of Tukwila, Washington. I understand that state law requires that all building construction contractors be registered with the State of Washington. The exceptions to this requirement are stated under Section 18.27.090 of the Revised Code of Washington, a copy of which is printed on the reverse side of this Affidavit. I have read or am familiar with RCW 18.27.090. 3. I understand that prior to issuance of a building permit for work which is to be done by any contractor, the City of Tukwila must verify either that the contractor is registered by the State of Washington, or that one of the exemptions stated under RCW 18.27.090 applies. 4. In order to provide verification to the City of Tukwila of my compliance with this requirement, I hereby attest that after reading the exemptions from the registration regyijement of RCW 18.27.090, I consider the work authorized under this building permit to be exempt under No. ! `i and will therefore not be performed by a registered contractor. understand that I may be waiving certain rights that I might otherwise have under state law in any decision to engage an unregistered contractor to perform construction work. n \applicationsl8.2004 affidavit in lieu of contractor registration 1. APPLICANT Signed and swom to before me this 15 day of (90 r 20 0 Residing at uri fj - werk PERMIT NO.: 7aoco-%5e NOTARY PUBLIC in and for the State of Washington, V i i i. , Ot , ct County. D 5 a9 -/ o Name as commissioned: My commission expires: states as follows: ;l,(Lwcx, , 18.27.090 Exemptions. This chapter shall not apply to: 1. 2. An authorized representative of the United States Govemment, the State of Washington, or any incorporated city, town, county, township, irrigation district, reclamation district or other municipal or political corporation or subdivision of this state; 3. Officers of the court when they are acting within the scope of their office; 4. Public utilities operating under the regulations of the utilities and transportation commission in construction, maintenance, or development work incidental to their own business; 5. Any construction, repair or operation incidental to the discovering or producing of petroleum or gas, or the drilling, testing, abandoning, or other operation of any petroleum or gas well or any surface or underground mine or mineral deposit when performed by an owner or lessee; 6. The sale or installation of any finished products, materials, or articles of merchandise which are not actually fabricated into and do not become a permanent fixed part of the structure; 7. Any construction, alteration, improvement or repair of personal property, except this chapter shall apply to all mobile, manufactured housing. A mobile/manufactured home may be installed, set up, or repaired by the registered or legal owner, by a contractor licensed under this chapter, or by a mobile/manufactured home retail dealer or manufacturer licensed under chapter 46.70 RCW; 8. Any construction, alteration, improvement, or repair carried on within the limits and boundaries of any site or reservation under the legal jurisdiction of the federal government; 9. Any person who only fumished materials, supplies, or equipment without fabricating them into, or consuming them in the performance of the work of the contractor; 10. Any work or operation on one undertaking or project by one or more contractors, the aggregate contract price of which for labor and materials and all other items is less than $500.00, such work, or operations being considered as of a casual, minor, or inconsequential nature. The exemption prescribed in this subsection does not apply in all instance wherein the work or construction is only a part of a larger or major operation, whether undertaken by the same or a different contractor, or in which a division of the operation is made into \applications\8 -2004 affidavit in lieu of contractor registration • contracts of amounts less than $500.00 for the purpose of the evasion of this chapter or otherwise. The exemption prescribed in this subsection does not apply to a person who advertises or puts out any sign or card or other device which might indicate to the public that he is a contractor, or that he is qualified to engage in the business of contractor, 11. Any construction or operation incidental to the construction and repair of irrigation and drainage ditches of regularly constituted irrigation districts or reclamation districts; or to farming, dairying, agriculture, viticulture, horticulture, or stock or poultry raising; or to clearing or other work upon land in rural districts for fire prevention purposes; except then any of the above work is performed by a registered contractor; 12. An owner who contracts for a project with a registered owner, 13. Any person working on his own property, whether occupied by him or not, and any person working on his residence, whether owned by him or not but his exemption shall not apply to any person otherwise covered by this chapter who constructs an improvement on his own property with the intention and for the purpose of selling the improved property; 14. Owners of commercial properties who use their own employees to do maintenance, repair, and alteration work in or upon their own properties; 15. A licensed architect or civil or professional engineer acting solely in his professional capacity, an electrician licensed under the laws of the state of Washington, or a plumber licensed under the laws of the state of Washington while operating within the boundaries of such political subdivision. The exemption provided in this subsection is applicable only when the licensee is operating within the scope of this Il r :Jr . 16. Any person wrie" ingages; activities herein regulated y es;',ah' e'Q gyee' of a registered contractor ,vith wagda§' Compensation; In" Ut 17. Contractors oh highway projei k Nho have been prequalifierEct tegUt'rec liy ch4t013 of the Laws of 1961, RG9llf X47, 8:67Q department of transportation titirforn\ highway construction, reconstruction, or inainten9Fice work. x