HomeMy WebLinkAboutPermit M95-0193 - LES SCHWAB'1‘ 7 - • • ' . ; . • • . • ,„... N" • • '• • • !;; • . • . • 441 LL l�S akivAici5 (ep r) CITY OF TUKWILA Department of Community Development - Building Division 6300 Southcenter Boul vard Tukwila WA 98188 (206) 431 -3670 aG� _ O l do MECHANICAL PERMIT APPIE���L�, AI" 1'[GtJ PLAN CHECK NUMBER hr\a5 -oia3 APPLICATION MUST BE FILLED OUT COMPLETELY FEES (for staff use only) DESCRIPTION BASIC PERMIT FEE UNIT(S) FEE PLAN CHECK FEE: AMOUNT RCPT # OTHER: TOTAL. SITE ADDRESS 0 146 l`� i SUITE # T 4oMe �v -�-- sty VALUE OF CONSTRUCTION - $ 59,Sjc�ob PROJECT NAME/TENANT Lam✓ 4FLJ E7 ASSESSOR ACCOUNT # 3(Q2c¢ci(014 LJA1`( 7 TYPE OF WORK: g New /Addition Q Modifications 0 Repair Q Other: lL LLt~ OgIZIP T7 -1,j- `i-' DESCRIBE WORK TO BE DONE: -nge - R .v1G -- GIN \ g CoFF 1Ge- W PeR�itsvSCE TYPE RATING/SIZE <. :.: ... ..:..:.:. _ :.. <`::;:::;:;:.:: <: NUMBER OF< UNIT'S';;:; >< ><;: ;;: •r:. -. I r — la ., . coo 00 ca ( WA. ST. CONTRACTOR'S LICENSE # Li-1 No deo 000 ti . 1 OC)Q EXP. DATE BUILDING USE (office, warehouse, etc.) t"� 1-0 Mc' j?, % L. -r R At t- -. e-• NATURE OF BUSINESS: .f 'r'c, HQ ie,1 L. E 11 eE S..l..-7 WILL THERE BE A CHANGE IN USE? No Q Yes IF YES, EXPLAIN: WILL THERE BE STORAGE OR USE OF FLAMMABLE, COMBUSTIBLE OR HAZARDOUS MATERIALS IN THE BUILDING? 0 N 0 Yes IF YES, EXPLAIN: PROPERTY OWNER L 5,e-, r✓(-E, Lj ,V5 -(-lg� c501 --.la. PHONE 5c., 3 44-7 / (62. ADDRESS tOl5 t'tfbr %gPci7 14K x LJA1`( 7 t1-\( lL LLt~ OgIZIP T7 -1,j- `i-' CONTRACTOR -i"o $t3 ,c7—m' �AA t v..) (s).0 1 PHONEt ZIP ADDRESS WA. ST. CONTRACTOR'S LICENSE # EXP. DATE 1 ;.HEREBY CERTIFY THAT1HAV ANDCORRECT, AND l AM AUT BUILDING OWNER OR AUTHORIZED AGENT SIGNATURE IZEO' ND EXAMINED THIS APPLICATION AND KNOWTHE SAMETO 0"A PINY t"OR THIS •P PRINT NAME 124cu L J G7 0 V*, 10(12+411 4%1\1 (Sr GT. . C✓ • 4) 1169 ADDRESS DATE (1 .BE TR PHONE CONTACT. PERSON e iAsv -207 CITY/ZIP l c,MI. q ci,cr PHONF(2C5 CI) 104- 52 d7 APPLICATION SUBMITTAL In order to ensure that your application is accepted for plan review, please make sure to fill out the application completely and follow the plan submittal checklist on the reverse side of this form. Application and plans must be complete in order to be accepted for plan review. BUILDING OWNER /AUTHORIZED AGENT If the applicant is other than the owner, registered architect/engineer, or contractor licensed by the State of Washington, a notarized letter from the property owner authorizing the agent to submit this permit application and obtain the permit will be required as part of this submittal. VALUATION OF CONSTRUCTION The valuation is for the work covered by this permit and must be filled in by the applicant. This figure is used for budget reporting purposes only and not to calculate your fees. EXPIRATION OF PLAN REVIEW Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may extend the time for action by the applicant for a period not exceeding 180 days upon written request by the applicant as defined in Section 304(d) of the Uniform Mechanical Code (current edition). No application shall be extended more than once. If you have any questions about our process or plan submittal requirements, please contact the Department of Community Development at 431 -3670. DATE APPLICATION ACCEPTED l(-- so— (15 DATE APPLICATION EXPIRES 5-Da- q (o 03114/04 SUE6IIITTAL CHECKLIST Ow. w. 3 iti i!r ,xia.i1 MECHANICAL n Completed mechanical permit application (one for each structure or tenant) n Two (2) sets of mechanical plans, which include: • Floor plan • System layout • Elevations (for roof mounted equipment) • Heat Loss Calculations Structural calculations stamped by a Washington State licensed engineer may be required if structural work is to be done (2 sets) Note: Hood and duct systems require a building permit for the duct shaft. Water heaters and vents are included in the UMC — please include any water heaters or vents being installed or replaced. CITY OF TUKUIi i Department of Community Development — Permit Cenfer 6300 Southcenter Boulevard - #100, Tukwila, WA 98188 (206) 431 -3670 Mechanical Permit Application Tracking PLAN CHECK NUMBER 'PO GS- 0193 PROJECT NAME 6chwo,b. SITE ADDRESS lo�ou 6 Igo �t SUITE NO. INSTRUCTIONS TO STAFF • Contacts with applicants or requests for information should be summarized in writing by staff so that the status of the project may be ascertained at any time. • Plan corrections shall be completed and approved prior to sending to the next department. • Any conditions or requirements for the permit shall be noted in the Sierra system or summarized concisely in the form of a formal letter or memo, which will be attached to the permit. • Please fill out your section of the tracking chart completely. Where information requested is not applicable, so note by using "N /A ", date and initial. DEPARTMENTAL REVIEW "X" In box indicates which departments need to review . the project. DEPAiR7MENT: SATE ;IN:'. DATE::. PROVE UIREMENT BUILDING - initial review O FIRE O PLANNING O OTHER I ►� ao-q5 RO TED 4 CONSULTANT: Date Sent - INIT: INIT: COMMENTS Date Approved - FIRE PROTECTION: • Sprinklers • Detectors • N/A FIRE DEPT. LETTER DATED: INSPECTOR: ZONING: IBAR/LAND USE CONDITIONS? lJ Yes U No SCREENING REQUIRED? 0 Yes 0 No REFERENCE FILE NOS.: INIT: O BUILDING - final review O BUILDING OFFICIAL UMC EDITION (year): INIT: INIT: .612/4 REVIEW COMPLETED AMOUNT OWING: 4iq t, ice- CONTACTED PI DATE NOTIFIED )- Q l(J BY: (init. EP" (,?� 2nd NOTIFICATION ( PCW 1 Y: (init. L BY: (init.) r l '/ ,0 3RD NOTIFICATION 01/07/93 • B :,DING SYSTEMS Rx, NORTHWEST 4. FAX (541) 548 -6221 (541) 548 -0115 112 S.W. 2nd Street, Suite D, Redmond, OR 97756 TRANSMITTAL TO: The Casey Group 10116 36th Ave Ct SW, Suite 109 Tacoma, Washington 98499 ATTN: Paul Casey RE: Les Schwab Tukwila WE ARE SENDING YOU: [X] ATTACHED FROM: Norm Nel on DATE: November 17, 1995 [ ] UNDER SEPARATE COVER SHOP DRAWINGS [X ] PRINTS [ ] DOCUMENTS [ ] SPECIFICATIONS [ ] TRACINGS CATALOGS COPY OF LETTER COPIES DATES ITEMS 1 1 1 1 11 -17 -95 11 -17 -95 11 -17 -95 11 -17 -95 Final Mechanical Drawings M1, M2, P1 and P2 Washington Code Compliance Forms c%'31.4-7✓(. cSL/ / HVAC Calculations Equipment Schedule (4N) DEG /AL) REMARKS: COPY TO: File al a woo APPS MA`s 221996 BUIL IN DIVISION RECEIVED CITY OF TUKWILA Nov 2 0 1995 PERMIT CENTER • Trane Air Conditioning Economics By: C.D.S. MARKETING ********************************************** * * * * * * * * * * * * * * * * * * * * * ** * * * * * * ** ** ** ** ** ** T R A C E 6 0 0 A N A L Y S I S by C.D.S. MARKETING ** ** A* ** ** ********************************************** * * * * * * * * * * * * * * * * * * * * * * * * * * * * * ** ********************************************** * * * * * * * * * * * * * * * * * * * * * * * * * * * * * ** TIRE CENTER TUKWILA, WASHINGTON LES SCHWAB DOUG PIERCE BLOCK LOAD FOR NEW TIRESTORE Weather File Code: Location: Latitude: Longitude: Time Zone: Elevation: Barometric Pressure: Summer Winter Summer Summer Winter Summer Winter Clearness Number: Clearness Number: Design Dry Bulb: Design Wet Bulb: Design Dry Bulb: Ground Relectance: Ground Relectance: Air Density: Air Specific Heat: Density- Specific Heat Prod: Latent Heat Factor: Enthalpy Factor: SEATTLE SEATTLE, WASHINGTON 47.0 (deg) 122.0 (deg) 8 386 (ft) 29.5 (in. Hg) 0.95 0.95 80 (F) 64 (F) 26 (F) 0.20 0.20 0.0749 0.2444 1.0988 4,836.9 4.4953 (Lbm /cuft) (Btu /lbm /F) (Btu- min. /hr /cuft /F) (Btu- min. /hr /cuft) (lb- min. /hr /cuft) Design Simulation Period: June To November System Simulation Period: January To December Cooling Load. Methodology: Time /Date Program was Run: Dataset Name: TETD /Time Averaging 15:16:39 11/17/95 LS_TUKWL .TM V 60 PAGE 0 RECEIVED CITY OF TUKWILA NOV 2 01995 PERMIT CENTER r Trane Air Conditioning Economics By: C.D.S. MARKETING AIRFLOW - ALTERNATIVE 1 GAS FURNACE S Y S T E M S U M M A R Y (Design Airflow Quantities) Main Auxil. Room Outside Cooling Heating Return Exhaust Supply Exhaust System ,system Airflow Airflow Airflow Airflow Airflow Airflow Airflow Number Type (Cfm) (Cfm) (Cfm) (Cfm) (Cfm) (Cfm) (Cfm) 1 SZ 1,632 2,712 2,712 2,712 1,632 0 0 2 RAD 7,064 0 0 0 7,064 0 0 Totals 8,696 2,712 2,712 2,712 8,696 0 0 CAPACITY - ALTERNATIVE 1 GAS FURNACE Main Sys. System System Capacity Number Type (Tons) 1 SZ 2 RAD Totals 8.5 0.0 8.5 Cooling S Y S T E M S U M M A R Y (Design Capacity Quantities) V 600 PAGE 1 Aux. Sys. Opt. Vent Capacity Capacity (Tons) (Tons) 0.0 0.0 0.0 0.0 0.0 0.0 Cooling Main Sys. Totals Capacity (Tons) (Btuh) The building peaked ENGINEERING CHECKS - ALTERNATIVE 1 GAS FURNACE System Main/ System Number Auxiliary Type 1 Main SZ 2 Main RAD 8.5 - 129,619 0.0 - 361,659 8.5 - 491,278 Aux. Sys. Capacity (Btuh) Preheat Capacity (Btuh) 0 -31,062 0 0 0 - 31,062 at hour 15 month 8 with a capacity of E N G I N E E R I N G CHECKS Percent Outside Cfm/ Air Sq Ft Cooling Cfm/ Sq Ft Ton /Ton Heating Reheat Capacity (Btuh) 0 0 0 8.5 tons Humidif. Opt. Vent Heating Capacity Capacity Totals (Btuh) (Btuh) (Btuh) 0 0 - 129,619 0 0 - 361,659 0 0 - 491,278 Btuh/ Sq Ft 60.18 0.63 317.7 504.4 23.79 0.00 0.00 0.0 0.0 0.00 -- Heating ---- Cfm/ Btuh/ Floor Area Sq Ft Sq Ft Sq Ft 0.63 -30.10 4,306 0.00 -76.80 4,709 Trane Air Conditioning Economics By: C.D.S. MARKETING SYSTEM CHECKSUMS System 1 Peak S2 - SINGLE ZONE * * * * * * * * * * * * * * * * * * * * * * * ** COOLING COIL PEAK * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * ** Peaked at Time =_> Mo /Hr: 8/15 Outside Air = => OADB /WB /HR: 78/ 64/ 70.0 Envelope Loads Skylite Solr Skylite Cond Roof Cond Glass Solar Glass Cond Watt Cond Partition Exposed Floor Infiltration Sub Total = => Internal Loads Lights People Misc Sub Total = => Ceiling Load Outside Air Sup. Fan Heat Ret. Fan Heat Duct Heat Pkup OV /UNDR Sizing Exhaust Heat Terminal Bypass Space Sens. +Lat. (Btuh) 0 0 0 0 0 611 0 0 0 611 19,400 65,295 14,697 99,392 4,648 0 69 Grand Total = => 104,720 Ret. Air Sensible (Ruh) 0 0 4,965 0 0 -317 4,648 0 0 0 -4,648 Main Clg Aux Ctg Opt Vent Totals Total Capacity (Tons) (Mbh) 8.5 102.4 0.0 0.0 0.0 0.0 8.5 102.4 * * * Ret. Air Net Percnt * Latent Total Of Tot (Btuh) (Btuh) (%) 0 0.00 * 0 0.00 * 4,965 4.85 0 0.00 * 0 0.00 * 294 0.29 * 0 0.00 0 0.00 0 -0.00 5,259 5.13 * * 19,400 18.94 * 65,295 63.74 * 0 14,697 14.35 0 99,392 97.02 * 0 0.00 * 0 0 -3,237 -3.16 964 0.94, * 0 0.00 * 0 0.00 * 69 0.07 * 0 0 0.00 * 0 0 0.00 * 0 0 0 0 0 0 102,447 100.00 COOLING COIL SELECTION V 600 PAGE 2 CLG SPACE PEAK * * * * * * * * * * ** HEATING COIL PEAK * * * * * * ** Mo /Hr: 7/16 * Mo /Hr: 13/ 9 OADB: 79 * OADB: 26 * Space Percnt * Space Peak Coil Peak Percnt Sensible of Tot * Space Sens Tot Sens Of Tot (Btuh) (X) * (Btuh) (Btuh) (%) 0 0.00 * 0 0 0.00 0 0.00 * 0 0 0.00 0 0.00 * 0 -3,811 2.94 0 0.00 * 0 0 0.00 0 0.00 * 0 0 0.00 970 1.33 * -6,125 - 11,728 9.05 0 0.00 * 0 0 0.00 0 0.00 * -4,586 -4,586 3.54 0 -0.00 * 0 0 0.00 970 1.33 * - 10,711 - 20,126 15.53 * 19,400 26.54 * 0 0 0.00 31,935 43.69 * 0 0 0.00 14,697 20.11 * 0 0 0.00 66,033 90.33 * 0 0 0.00 6,030 8.25 * -9,414 0 0.00 0 0.00 * 0 - 75,326 58.11 0.00 * 0 0.00 0.00 * 0 0.00 0.00 * 0 0.00 69 0.09 * - 34,167 - 34,167 26.36 0.00 * 0 0.00 0.00 * 0 0.00 * 73,101 100.00 * - 54,292 - 129,619 100.00 AREAS Gross Total Glass (sf) (X) Sens Cap. Coil Airfl Entering DB /WB /HR (Mbh) (cfm) Deg F Deg F Grains 72.7 2,712 78.1 64.6 71.0 0.0 0 0.0 0.0 0.0 0.0 0 0.0 0.0 0.0 HEATING COIL SELECTION Leaving DB /WB /HR Deg F Deg F Grains 53.1 51.8 56.2 0.0 0.0 0.0 0.0 0.0 0.0 AIRFLOWS (cfm) Capacity Coil Airfl Ent Lvg Type Cooling. Heating (Mbh) (cfm) Deg F Deg F Vent 1,632 1,632 Main Htg -129.6 2,712 42.7 86.2 Infil 0 0 Aux Htg 0.0 0 0.0 0.0 Supply 2,712 2,712 Preheat -31.1 2,712 42.7 53.1 Mincfm 0 0 Reheat 0.0 0 0.0 0.0 Return 2,712 2,712 Humidif 0.0 0 0.0 0.0 Exhaust 1,632 1,632 Opt Vent 0.0 0 0.0 0.0 Rm Exh 0 0 Total -129.6 Auxil • 0 0 -- ENGINEERING Clg % OA Clg Cfm /Sqft Clg Cfm /Ton Clg Sqft/Ton Clg Btuh /Sqft No. People Htg X OA Htg Cfm /SqFt Htg Btuh /SqFt Floor ExFlr Roof Wall CHECKS- - 60.2 0.63 317.68 504.41 23.79 101 60.2 0.63 -30.10 4,306 Part 0 188 3,757 3,171 0 0 775 24 -- TEMPERATURES (F) - -- Type Clg Htg SADB 53.5 86.2 Plenum Return Ret /OA Runarnd Fn MtrTD Fn BIdTD Fn Frict 82.0 78.0 78.1 78.0 0.1 0.1 0.2 59.8 68.0 42.7 68.0 0.1 0.1 0.2 Trane Air Conditioning Economics By: C.D.S. MARKETING SYSTEM CHECKSUMS System 2 * * * * * * * * * * * * * * * * * * * * * * * ** COOLING COIL PEAK Peaked at Time =_> Mo /Hr: 0/ 0 Outside Air =_> OADB /WB /HR: 0/ 0/ 0.0 Block RAD - RADIATION * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * ** CLG SPACE PEAK * Mo /Hr: 0/ 0 * OADB: 0 * * Space * Sensible * (Btuh) * Envelope Loads Skylite Solr Skylite Cond Roof Cond Glass Solar Glass Cond Wall Cond Partition Exposed Floor Infiltration Sub Total = => Internal Loads Lights People Misc Sub Total = => Ceiling Load Outside Air Sup. Fan Heat Ret. Fan Heat Duct Heat Pkup OV /UNDR Sizing Exhaust Heat Terminal Bypass Grand Total = => Space Ret. Air Sens. +Lat. Sensible (Btuh) (Btuh) 0 Main Clg Aux Clg Opt Vent Totals Main Htg Aux Htg Preheat Reheat Humidif Opt Vent Total Total Capacity (Tons) (Mbh) 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 HEATING COIL SELEC Capacity Coil Air (Mbh) (cfm) -361.7 0.0 0.0 0.0 0.0 0.0 -361.7 0 0 0 0 0 0 0 0 0 0 0 Ret. Air Latent (Btuh) 0 0 0 0 0 0 Net Total (Btuh) COOLING COIL SELECTION Sens Cap. (Mbh) 0.0 0.0 0.0 ION l Ent Deg F 0.0 0.0 0.0 0.0 0.0 0.0 Percnt Of Tot (%) 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 * 0.00 * 0.00 0.00 * 0.00 * 0.00 * 0.00 * 0.00 0.00 * 0.00 * 0.00 * 0.00 * 0.00 * * 0.00 * • 0 * * * * * * * * * * ** * * * Percnt * Of Tot * (%) 0.00 * 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0 0.00 Coil Airfl Entering DB /WB /HR (cfm) Deg F Deg F Grains 0 0.0 0.0 0.0 0 0.0 0.0 0.0 0 0.0 0.0 0.0 AIRFLOWS (cfm) Leaving DB /WB /HR Deg F Deg F Grains 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 Lvg Type Coolin Heating Deg F Vent 7,06 0.0 lnfil 0.0 Supply 0.0 Mincfm 0.0 Return 0.0 Exhaust 0.0 Rm Exh Auxil V 600 PAGE 3 HEATING COIL PEAK Mo /Hr: 13/ 9 OADB: 26 Space Peak Space Sens (Btuh) 0 0 0 0 0 - 16,336 0 -7,568 0 - 23,904 0 0 0 0 - 11,749 - 326,005 0 Coil Peak Tot Sens (Btuh) 0 0 -4,821 -23,26 -7,56 -35,65 - 326,00 - 361,659 - 361,65 Gross Floor Part ExFlr Roof Wall AREAS * * * * * * ** Percnt Of Tot (x) 0.00 0.00 1.33 0.00 0.00 6.43 0.00 2.09 0.00 9.86 0.00 0.00 0.00 0.00 0.00 90.14 0.00 0.00 0.00 0.00 0.00 0.00 100.00 Total Glass (sf) (7.) 4,709 0 311 4,709 5,310 -- ENGINEERING CHECKS- - Clg % OA 0.0 Clg Cfm /Sqft 0.00 Clg Cfm /Ton 0.00 Clg Sqft/Ton 0.00 Clg Btuh /Sqft 0.00 No. People 0 Htg % OA 0.0 Htg Cfm /SqFt 0.00 Htg Btuh /SqFt -76.80 0 0 756 14 -- TEMPERATURES (F) --- Type Clg Htg SADB 0.0 68.1 Plenum 0.0 60.1 Return 0.0 60.1 .Ret /OA Runarnd Fn MtrTD Fn BIdTD Fn Frict 0.0 60.1 0.0 68.0 0.0 0.0 0.0 0.0 0.0 0.0 Trane Air Conditioning Economics By: C.D.S. MARKETING MAIN SYSTEM COOLING - ALTERNATIVE 1 GAS FURNACE PEAK COOL I N G LOADS (Main System) V 600 PAGE 4 Space Coil Peak OA Rm Supp. Space Space Space Peak OA Rm Supp. Coil Coil Coil Time Cond. Dry Dry Air Sens. Lat. Time Cond. Dry Dry Air Sens. Lat. Room Mo /Hr DB /WB Blb Bulb Flow Load Load Mo /Hr DB /WB Blb Bulb Flow Load Load Number Description (F) (F) (F) (Cfm) (Btuh) (Btuh) (F) (F) (F) (Cfm) (Btuh) (Btuh) 101 SHOW ROOM 7/16 79 63 78 53.5 1,949 52,535 28,436 8/15 78 64 78 54.0 1,949 52,575 25,807 102 SALES AREA 7/17 78 61 78 53.5 274 7,387 1,040 7/16 79 63 78 53.9 274 7,579 890 103 CUSTOMER LOUNGE 7/16 79 63 78 53.5 222 5,975 1,950 8/15 78 64 78 54.1 222 5,419 1,770 106 MENS ROOM 9/19 70 58 78 53.5 28 743 0 9/19 70 58 78 54.2 28 725 0 107 WOMENS ROOM 7/15 80 64 78 53.5 18 481 0 7/15 80 64 78 54.4 18 404 0 201 MANAGERS OFFICE 7/16 79 63 78 53.5 52 1,393 325 8/15 78 64 78 54.2 52 1,366 285 202 LOCKER ROOM 7/16 79 63 78 53.5 150 4,036 1,305 7/14 79 65 78 55.0 150 4,044 1,005 203 EMPLOYEE RESTRM 9/19 70 58 78 53.5 20 550 0 9/19 70 58 78 54.2 20 578 0 Zone 1 Total /Ave. 79 63 78 53.5 2,712 73,101 33,056 78 64 78 54.0 2,712 72,690 29,756 Zone 1 Block 7/16 79 63 78 53.5 2,712 72,986 33,316 8/15 78 64 78 54.1 2,712 72,073 30,046 System 1 Total /Ave. 79 63 78 53.5 2,712 73,101 33,056 78 64 78 54.0 2,712 72,690 29,756 System 1 Block 7/16 79 63 78 53.5 2,712 72,986 33,316 8/15 78 64 78 54.1 2,712 72,073 30,046 MAIN SYSTEM HEATING - ALTERNATIVE 1 GAS FURNACE PEAK HEATING LOADS (Main System) Space Coil Peak OA Rm Supp. Space Space Peak OA Rm Supp. Coil Coil Floor Time Cond. Dry Dry Air Sens. Time Cond. Dry Dry Air Sens. Room Area Mo /Hr DB /WB Blb Bulb Flow Load Mo /Hr DB /WB Blb Bulb Flow Load Number Description (Sq Ft) (F) (F) (F) (Cfm) (Btuh) (F) (F) (F) (Cfm) (Btuh) 101 SHOW ROOM 2,625 13/ 1 26 23 68 86.2 1,949 - 39,018 13/ 9 26 23 68 86.2 1,949 - 99,588 102 SALES AREA 679 13/ 1 26 23 68 86.2 274 -5,486 13/ 9 26 23 68 86.2 274 -8,255 103 CUSTOMER LOUNGE 441 13/ 1 26 23 68 86.2 222 -4,438 13/ 9 26 23 68 86.2 222 -8,591 106 MENS ROOM 58 13/ 1 26 23 68 86.2 28 -552 13/ 1 26 23 68 86.2 28 -552 107 WOMENS ROOM 50 13/ 1 26 23 68 86.2 18 -357 13/ 1 26 23 68 86.2 18 -357 201 MANAGERS OFFICE 113 13/ 1 26 23 68 86.2 52 -1,035 13/ 9 26 23 68 86.2 52 -1,958 202 LOCKER ROOM 299 13/ 1 26 23 68 86.2 150 -2,998 13/ 9 26 23 68 86.2 150 -9,909 203 EMPLOYEE RESTRM 41 13/ 1 26 23 68 86.2 20 -409 13/ 1 26 23 68 86.2 20 -409 Zone 1 Total /Ave. 4,306 26 23 68 86.2 2,712 - 54,293 26 23 68 86.2 2,712 - 129,619 Zone 1 Block 4,306 13/ 1 26 23 68 86.2 2,712 - 54,292 13/ 9 26 23 68 86.2 2,712 - 129,618 System 1 Total /Ave. 4,306 26 23 68 86.2 2,712 - 54,293 26 23 68 86.2 2,712 - 129,619 System 1 Block 4,306. 13/ 1 26 23 68 86.2 2,712 - 54,292 13/ 9 26 23 68 86.2 2,712 =129,618 2,108 SERVICE BAYS 4,709 13/ 9 26 23 68 68.1 0 - 361,659 13/ 9 26 23 68 68.1 0 - 361,659 Zone 2 Total /Ave. 4,709 26 23 68 68.1 0 - 361,659 26 23 68 68.1 0 - 361,659 Zone 2 Block 4,709 13/ 9 26 23 68 68.1 0 -361,659 .13/ 9 26 23 68 68.1 0 - 361,659 System 2 Total /Ave. 4,709 26 23 68 68.1 0 - 361,659 26 23 68 68.1 0 - 361,659 System 2 Block 4,709 13/ 9 26 23 68 68.1 0 - 361,659 13/ 9 26 23 68 68.1 0 - 361,659 Trane Air Conditioning Economics By: C.D.S. MARKETING BUILDING U-VALUES - ALTERNATIVE 1 GAS FURNACE B U I L D I N G U- VALUES Room U- Values Room Room (Btu /hr /sqft /F) Mass Capac. Room Sunmr Wintr Summr Wintr (lb/ (Btu/ Number Description Part. ExFlr Skylt Skylt Roof Windo Windo Wall Cell. sqft) sqft /F) 101 SHOW ROOM 0.000 0.580 0.000 0.000 0.030 0.570 0.598 0.130 0.260 70.2 14.94 102 SALES AREA 0.000 0.580 0.000 0.000 0.030 0.570 0.598 0.130 0.260 64.9 13.87 103 CUSTOMER LOUNGE 0.000 0.580 0.000 0.000 0.000 0.000 0.000 0.130 0.260 17.5 3.49 106 MENS ROOM 0.000 0.580 0.000 0.000 0.000 0.000 0.000 0.130 0.317 68.6 13.73 107 WOMENS ROOM 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.317 13.3 2.67 201 MANAGERS OFFICE 0.000 0.000 0.000 0.000 0.030 0.000 0.000 0.000 0.317 31.1 7.13 202 LOCKER ROOM 0.000 0.000 0.000 0.000 0.030 0.000 0.000 0.130 0.317 40.2 8.94 203 EMPLOYEE RESTRM 0.000 0.000 0.000 0.000 0.030 0.000 0.000 0.130 0.317 97.6 20.41 Zone 1 Total /Ave. 0.000 0.580 0.000 0.000 0.030 0.570 0.598 0.130 0.267 60.5 12.87 System 1 Total /Ave. 0.000 0.580 0.000 0.000 0.030 0.570 0.598 0.130 0.267 60.5 12.87 2,108 SERVICE BAYS 0.000 0.580 0.000 0.000 0.030 0.500 0.522 0.130 0.317 86.0 18.10 Zone 2 Total /Ave. 0.000 0.580 0.000 0.000 0.030 0.500 0.522 0.130 0.317 86.0 18.10 System 2 Totat /Ave. 0.000 0.580 0.000 0.000 0.030 0.500 0.522 0.130 0.317 86.0 18.10 Building 0.000 0.580 0.000 0.000 0.030 0.535 0.560 0.130 0.293 73.8 15.60 BUILDING AREAS - ALTERNATIVE 1 GAS FURNACE Floor Number of Area /Dupl Room Duplicate Room Number Description Flr Rm (sqft) 101 SHOW ROOM 1 1 2,625 102 SALES AREA 1 1 679 103 CUSTOMER LOUNGE 1 1 441 106 MENS ROOM 1 1 58 107 WOMENS ROOM 1 1 50 201 MANAGERS OFFICE 1 1 113 202 LOCKER ROOM 1 1 299 203 EMPLOYEE RESTRM 1 1 41 Zone 1 Total /Ave. System 1 Total /Ave. 2,108 SERVICE BAYS 1 1 4,709 Zone 2 Total /Ave. System 2 Total /Ave. Building B U I L D I N G AREAS V 600 PAGE 5 Total Exposed Floor Partition Floor Skylight Skl Area Area Area Area /Rf (sqft) (sqft) (sqft) (sqft) (7.) 2,625 679 441 58 50 113 299 41 4,306 4,306 4,709 4,709 4,709 9,016 141 30 9 8 0 0 0 0 188 188 311 311 311 499 Net Roof Window Win Net Wall Area Area /Wl Area (sqft) (sqft) (%) (sqft) 2,625 64 2 1,808 679 12 2 403 0 32 0 57 0 0 113 0 299 48 41 48 3,757 77 2 2,396 3,757 77 2 2,396 4,709 75 1 4,554 4,709 75 1 4,554 4,709 75 1 ' 4,554 8,466 1,531 1 6,950 • Trane Air Conditioning Economics By: C.D.S. MARKETING ASHRAE 90 ANALYSIS - ALTERNATIVE 1 GAS FURNACE ASHRAE V0 ANALYSIS Overall Roof U-Value = Overall Wall U'Vuiue = Overall Building u'vm(uo = Roof Overall Thermal Transfer Null Overall Thermal Transfer -&k2o 0,030 (Btu/Hr/Sq Ft/F) 0.303 (Btu/Hr/on Ft/F) 0.117 (Btu/Ur/on Ft/F) Value (OTTVr) = 1.01 (otu/Un/oq Ft) V 600 PAGE 6 *� Li`i' i'ouirUil�y'aysiein+3 riii " Paul Casey BS& 112 SW 2nd St. Suite [J Date :11718195' Time: 11:85 :24 Page 1 of 8 BLING SYSTEMS RX, NORTHWEST Redmond, Oregon 97756 • (541)548.0115 • Fax: (541)548.6221 FAX TRANSMITTAL To: Paul Casey Date: November 16, 1995 NO. Of Pages: 8 Sender: Doug Pierce Re: Les Schwab Tire Store Tukwila Fax: (206)581 -9720 YOU SHOULD RECEIVE 8 PAGE(S), INCLUDING THIS COVER SHEET. IF YOU DO NOT RECEIVE ALL THE PAGES, PLEASE CALL (503)548-0115. REMARKS: Paul, Here are the energy code compliance forms for Washington. All you will need, to my knowledge, is the first page labeled Component Performance Method. I included the other sheets to show you how I calculated the areas. You may want to adcl the wall area sheet with the calculations as the state sends the calculation table to other firms to check our calculations. Of course you may already know that. The way I calculated the U -Value for the Loose Fill walls is shown on the first block wall calculation sheet. If you have any questions about anything please call me and I will try to help. I will send a hard copy to you in the mail with the drawings. Doug, ; r uii`i; c+iifiuiiiy'�ystettis''I <li "f or Paul Casey Date: 11/16/95 -TIMei "'f1:56t16 WASHINLJN ENERGY CODE COMPLIANCE REQLEMENTS COMPONENT PERFORMANCE METHOD Page 2 of 8 PROJECT NAME: LES SCHWAB ALIGNMENT CENTER LOCATION: TUKWILA, WASHINGTON CALCULATED BY: DOUG PIERCE CHECKED BY: NORM NELSON DATE: 16- Nov -95 AREAS TOTAL AREA A MAXIMUM U -VALUE U ACTUAL. U -VALUE U1 TARGET THERMAL TRANSMITTANCE UxA PROPOSED TRANSMITTANCE U1 x ROOFS OVER ATTICS 0.00 0.03 0.00 0.00 0,00 ALL OTHER ROOFS 9,056.50 0.03 0.03 307.92 292.90 OVERHEAD GLAZING 0.00 0.80 0.00 0.00 0.00 OVERHEAD GLAZING IN OTHER ROOFS 0.00 0.00 0.00 0.00 0,00 OPAQUE WALLS 7,529.47 0.25 0,26 1882.37 1972.65 VERTICAL GLAZING 251.00 0.40 0.70 100.40 175.70 OPAQUE DOORS 1,596.00 0,60 0,12 957.60 190.53 FLOORS OVER UNCOND. SPACE 0.00 0.03 0.00 0.00 0.00 LINEAL FEET OF SLAB ON GRADE 538.67 0.54 0.54 290.88 290,88 BELOW GRADE OPAQUE WALLS 0,00 0.54 0.00 0.00 0.00 RESULTS OF EQUATION 13-1 (TARGET UA) (from page 127 of Washington State Energy Code) RESULTS OF EQUATION 13-2 ACTUAL UA) (from page 129 of Washington State Energy Code) NOTE: Total Wall heat Capacity exceeds 9.0 Btu /soft • °F Therfore, Maximum U -Value of .25 is allowed. 3539.17 2922.65 Les Schwab Tire Store, Tukwila, WA Building Systems RX " Dimensions ONLY, do not reflect subtraction of windows and doors. I From:'Buitding Systems RX' To:" Paul Ca §ey ^Datei�('1116795Time�1':57i05 �' WASHINGLN ENERGY CODE COMPLIANCE REQ ,«MENTS OPAQUE WALLS AND DOORS TYPE SERVICE BAY Ser. Bay W. Wall Ser. Bay N. Wall Ser. Bay S. Wall Personel Door Doors ** (35' -0 "x20' -7 ") (138'8 "x13') (138'8 "x23'6 ") 3 *(7'x3') (9x(12'x12')) REST OF BUILDING ** W. Wall (35' -0 "x20' -7 ") E. Wall (70'-8"x20'-5") S. Wall (59' -2 "x1818 ") N. Wall (60' -0 "x13'10) Personel Door 2 *(75(3') TOTALS AVERAGE U FOR WALLS AVERAGE U FOR DOORS AREA U -VALUE UA SF BTUHISF -F BTUHIF 701 0.315 221 291 0.315 92 3,217 0.254 817 63 0.600 38 1,512 0.086 130 0 0.000 0 AVERAGE U FOR OPAQUE SURFACES 644 0.254 164 1135 0.254 288 943 0.254 240 599 0.254 152 42 0.600 25 9,146 2,166 0.262 0.119_ r---75.741 Les Schwab Tire Store, Tukwila, WA Page Building Systems RX rom: d�ifding Systems R`io °paui'Casey Date: 11/16/95 Time: 11:57:45 WASHINCrbN ENERGY CODE COMPLIANCE REQl7TrEMENTS ROOFS AND SKYLIGHTS TYPE AREA U -VALUE UA SF BTUHISF•F BTUHIF TYPICAL ROOF 4,853 0.03 149 SERVICE BAY ROOF 4,203 0.03 144 0 0.000 0 0 0.000 0 0 0.000 0 0 0.000 0 0 0.000 0 0 0.000 0 0 0.000 0 0 0.000 0 0 0.000 0 TOTALS 9,056 293 AVERAGE U 0.032 Page 4 of 8 Les Schwab Tire Store, Tukwila,, WA Building Systems.RX :ptr Y. ....._......_.- ..:..�..... .... riwii. eu,i�i i a sinrii' "i' A •101 PawQuse Data • 1111t3ia5_..1WO:`1I btf:1if___._� BLOCK WALL WASHINC'ON ENERGY CODE COMPLIANCE REC,ZEMENTS WALL U -VALUE COMPONENT DESCRIPTION THICKNES- R -VALUE WEIGHT MOVING AIR BRICK AIR SPACE CONCRETE BLOCK FRAMING /INSULATION GYPSUM WALLBOARD STILL AIR 8" CMU With Perlite Filled Cores (, ' `•�' i..R :;::'hJ'i�.�w. 0.17 0.00 NIA 0.00 0.00 N/A 0.00 0.00 8.00 4.35 35.00 N/A 0.00 0.00 N/A 0.00 0.00 .•''= ".i`'' °''a 0.68 0.00 TOTAL R -VALUE TOTAL WEIGHT U -VALUE = 1/R TDeq 50% of wall Solid Grout @ U- Value: Total Combined U -Value = (.19 + .32)/2 5.20 0.19 0.32 0.25 35.00 37.001 Les Schwab Tire Store, Tukwila, WA. Building Systems RX rrrirti;"es' fil6'i`ri j }Sjist " "dri5s "1t3C"T$: ""Pali, Casey" WASHIN BLOCK WALL WALL U -VALUE JN ENERGY CODE COMPLIANCE REQLMENTS Page 6 of 8 COMPONENT DESCRIPTION THICKNESS R -VALUE WEIGHT MOVING AIR BRICK AIR SPACE CONCRETE BLOCK FRAMING /INSULATION GYPSUM WALLBOARD STILL AIR 8" Solid Grout CMU Block I :11: i;r° It 0.17 0.00 N/A 0.00 0.00 N/A 0.00 0.00 8.00 2.32 35.00 N/A 0,00 0.00 N/A 0.00 0.00 c .t' .rww 0.68 0.00 IVIML !\- VP'LVC TOTAL WEIGHT U -VALUE = 1/R TDeq 3.17 1 0.32 35.00 37.001 Les. Schwab Tire Store, Tukwila, WA Building Systems RX From! `btding''S stems K To: 'Paul Casey Date: 11118195 Time: 11 :59 :39 WASHINLN ENERGY CODE COMPLIANCE REQKLMENTS ROOF BUILT -UP ROOF ON METAL DECK - Store Area _ Page 7 of 8 COMPONENT DESCRIPTION THICKNES R -VALUE MOVING AIR r ^' . 0.17 BUILT -UP ROOF 3.00 0.33 INSULATION R -38 0,00 0.00 METAL TRUSS /INSULATION Metal Truss 4' -0" o.c. 0.00 28.12 AIR SPACE 8.00 0.84 INTERIOR FINISH Acoustical Ceiling Tile 0.75 2.48 STILL AIR :� "r';; :. 0.61 TOTAL R -VALUE U -VALUE = 1/R 0.03 Les Schwab Tire Store, Tukwila, WA Building :Systems RX rroii :'' uiiai igh'Sysiems'k'x 'i'o:'raw casey • " ' " ° "'DafeT 11718/95 Tfine: 12:00:19 WASHING N ENERGY CODE COMPLIANCE REQI,`:MENTS ROOF BUILT -UP ROOF ON METAL DECK - Service Bay Area WALL U -VALUE Page $of8" COMPONENT DESCRIPTION THICKNESS R -VALUE MOVING AIR BUILT -UP ROOF INSULATION METAL TRUSS /INSULATION AIR SPACE INTERIOR FINISH STILL AIR R -38 Metal Truss 4' -0" 0.c. Inagangla 0.17 3.00 0.33 0,00 0.00 0.00 28.12 8.00 0.00 0.00 0.00 : k till s'''' ' 0.61 TOTAL R -VALUE U -VALUE = 1/R 29.23 1 0.03 Les Schwab Tire Store, Tukwila, WA Building Systems RX