Loading...
HomeMy WebLinkAboutPermit M95-0208 - BOEING EMPLOYEES CREDIT UNION (BECU)fs'! 5.^ 5,�j gOE1F16 ■ erYlpime•E5 CROAT UkttO14 City of Tukwila C (206) 431 -3670 Community Development / Public Works • 6300 Southcenter Boulevard, Suite 100 • Tukwila, Washington 98188 MECHANICAL PERMIT Permit No: M95 -0208 Type: B- MECHAN Category: NRES Address: 12770 GATEWAY DR Location: Parcel #: 271600 -0075 Contractor License No: MACDOM *248J9 Status: ISSUED Issued: 12/13/1995 Expires: 06/10/1996 Suite: TENANT BOEING EMPLOYEES CREDIT UNION 12770 GATEWAY DR, TUKWILA, WA 98188 OWNER BOEING EMPLOYEES CREDIT UN Phone: (206)439 -5961 PO BOX 97050, SEATTLE..WA981249750 CONTRACTOR MACDONALD MILLER`CO 7717 DETROIT-.'SW, SEATTLE, WA'98106 CONTACT ANDRE BRASSEUR Phone: 206 743 -9400 7717 DETROIT AVENUE S.W., 5EATTLE, WA 9810;6:, **' k******' k******************** *** * *"k * **'k * * **'k*** * *."k * * *'k *.* r* ** * * ** * *•k* **'k'k** Permit Descri:"p,t'ion: REMOVEtl:;ONE HEAT PUMP AND. ONE VAV:.ZONE, VARIOUS DIFFUSERS,, GRILLE AND T -S,TAT LOCATION CHANGES-AND: MODIF,ICATLONS . Phone: 206 763 -9400 UMC Edition:'1994 Valuation: Total Permit Fee: '500.00 58.13 *****c***************** 'k * * * * * * * * *** *. *' ** k,*******' k * * * * * * *'k* *'k' * *'k** *'k * * * * ** Ifaild COW' Permit Center Authorized Signature Date I hereby .. certify that I have read 'and: examined this permit and know the same to be true and correct. All provisions of law and ordinances governing 'this, work will be complied with, whether specified herein or not The granting of this permit does not presume to give authority to violate or cancel` the provisions of any other state or local laws regulating construction, or the performance of work. -I 'am authorized to sign for and obtain this building Signature:__ Date: This permit shall become null and;`void f'th'e' work is not commenced within 180 days from the date of issua'nde, orif "'the work is suspended or abandoned for a period of 180 days from the last inspection. CITY OF TUKVVA.... Department of Community Development — Permit Center 6300 Southcenter Boulevard - #100, Tukwila, WA 98188 (206) 431 -3670 Mechanical Permit Application Tracking PLAN CHECK NUMBER CYl0l:1-5- o@Cg; PROJECT NAME locr2:1 CONTACTED ci f U h i cn SITE ADDRESS lailo cfr:. a.i A>r V SUITE NO. INSTRUCTIONS TO STAFF • Contacts with applicants or requests for information should be summarized in writing by staff so that the status of the project may be ascertained at any time. • Plan corrections shall be completed and approved prior to sending to the next department. • Any conditions or requirements for the perrnit shall be noted in the Sierra system or summarized concisely in the form of a formal letter or memo, which will be attached to the permit. • Please fill out your section of the tracking chart completely. Where information requested is not applicable, so note by using "N /A ", date and initial. DEPARTMENTAL REVIEW "X" in box indicates which departments need to review the project. DEPARTMENT DATE. IN BUILDING initial review l DATE AP PROVED REQUIREMENTS / COMMENTS • 12 ( ED) CONSULTANT: Date Sent - Date Approved - 0 FIRE FIRE PROTECTION: Q Sprinklers U Detectors UN /A INIT: FIRE DEPT. LETTER DATED: INSPECTOR: Li PLANNING INIT: ZONING: IBAR/LAND USE CONDITIONS? 0 Yes L) N SCREENING REQUIRED? 0 Yes 0 No REFERENCE FILE NOS.: �! OTHER BUILDING - final review INIT: BUILDING OFFICIAL INIT: r� J . y5 INIT:� UMC EDITION (year): REVIEW COMPLETED AMOUNT 'OWING: AI �, 3 CONTACTED DATE NOTIFIED I d r1 --t 3- GIS (init.) V 2nd NOTIFICATION BY: (init.) 3RD NOTIFICATION BY: (init.) 01/07/93 MECHAN.CAL PERMIT APPLICATION CITY OF TUKWILA Department of Community Development - Building Division 6300 Southcenter Boulevard, Tukwila WA 98188 DESCRIPTION (206) 431 -3670 FEES (for staff use only) PLAN CHECK In, G NUMBER u_cJ-_Q���� APPLICATION MUST BE FILLED OUT COMPLETELY BASIC PERMIT FEE UNIT(S) FEE PLAN CHECK FEE AMOUNT RCPT.# MINE OTHER: TOTAL' SITE ADDRESS /�� SUITE # /2 7/D /asl/ 1 /41 /J/ ��// Ill ,n1G49 VALUE OF CONSTRUCTION - $ () 6b0 PROJECT NAME/TENANT %22 ?V6 t i/ej ZFV /r /4//0/e/ ASSESSOR ACCOUNT # 2>/ G4D -.WA— TYPE OF WO K: 0 New /Addition ['Modifications Q Repair Q Other: DESCRIBE WORK TO BE DONE:A / 'ji'd'E / /4-,917)//,W) /Iwo / /W 2erA/E 0,44%6 /4,6 e/ , l >,'i1e., fi T AMT LDC.9rax/ G' /M,/d...s ,f4?/ >%ZW/ //i 4 -.16/ 46 :. ...::::�';;: <: ;;:::>:»:::»:;:< �€>: : >:;::: >?::.:.:::�::::;, >:. N M ER F NIT .......... 1:::::::::i1::;: :: TYPE .... ;.. .. : ..........: RATING/Sill» .. .....:...:.. ...:........... .. PHONE /iz) ADDRESS 77/7 �`j,F!' /r' 'J�� �l3 IZIP /4G WA. ST. CONTRACTOR'S LICENSE #4e`]6m * 254,4_9 BUILDING USE (office, warehouse, etc.) ‘4�F /L, NATURE OF BUSINESS: >10,92,,,/4t i l -)e.E= 4'.1-/2/r" "4/10/1 WILL THERE BE A CHANGE IN USE? ''No 0 Yes IF YES, EXPLAIN: WILL THERE BE STORAGE OR USE OF FLAMMABLE, COMBUSTIBLE OR HAZARDOUS MATERIALS IN THE BUILDING? [No 0 Yes IF YES, EXPLAIN: PROPERTY OWNER At./N/ 2.- 740//9,,,..3 .�.G) /r �,c/rr%c/ fi/A PHONE(a6) 67 - SIGf ZIP#/2Y - Jean ADDRESS Ail, Yr?sl-) ..4r72 CONTRACTOR ? ! 1�%A /�!�A /t � �_ i%« �,�° li . PHONE /iz) ADDRESS 77/7 �`j,F!' /r' 'J�� �l3 IZIP /4G WA. ST. CONTRACTOR'S LICENSE #4e`]6m * 254,4_9 EXP. DATE /` /l 9G I HEREBY CERTIFY THAT 1HAVE READAND EXAMINED: THIS APPLICATION :AND KNOW.THE SAMETO: i AND CORRECT, AND i AM AUTHORIZED TO APPLY<FOR:'1I IS PE MIT. <' DATE BUILDING OWNER OR AUTHORIZED SIGNATURE � /,� PRINT NAME ,w' A,e/96 /, BETR /2 /iV/476" PHONE (2ibj 74,3 -Wee AGENT ADDRESS 77/7 z- 'rte`, /r l CITY I ir4O /0% CONTACT PERSON PHONE i� aew APPLICATION SUBMITTAL In order to ensure that your application is accepted for plan review, please make sure to fill out the application completely and follow the plan submittal checklist on the reverse side of this form. Application and plans must be complete in order to be accepted for plan review. BUILDING OWNER /AUTHORIZED AGENT If the applicant is other than the owner, registered architect/engineer, or contractor licensed by the State of Washington, a notarized letter from the property owner authorizing the agent to submit this permit application and obtain the permit will be required as part of this submittal. VALUATION OF CONSTRUCTION The valuation is for the work covered by this permit and must be filled in by the applicant. This figure is used for budget reporting purposes only and not to calculate your fees. EXPIRATION OF PLAN REVIEW Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may extend the time for action by the applicant for a period not exceeding 180 days upon written request by the applicant as defined in Section 304(d) of the Uniform Mechanical Code (current edition). No application shall be extended more than once. If you have any questions about our process or plan submittal requirements, please contact the Department of Community Development at 431 -3670. DATE APPLICATION ACCEPTED DATE APPLICATION EXPIRES q5 ct(p 03/14194 SUE6IIITTAL CHECKLT MECHANICAL Completed mechanical permit application (one for each structure or tenant) Tw (ts of mechanical plans, which include: • Floor plan • System layout • Elevations (for roof mounted equipment) • Heat Loss Calculations Structural calculations stamped by a Washington State licensed engineer may be required if structural work is to be done (2 sets) Note: Hood and duct systems require a building permit for the duct shaft. Water heaters and vents are included in the UMC — please include any water heaters or vents being installed or replaced. • =22=22=2M244 DEPARTMENT OF LABOR AND INDUSTRIES 7-Hip CERTIFIES THAT THE PERSON NAMED.HEREON. IS REGISTERED AS PROVIDED BY LAW AS A • •••••• • • • .... : • -....,....':;.; Rg91-...--.-.,• -- - • • ''''''.1g.::,•;[!7••.!:s: •-;....-- ::..• ' - sTRA—tiON•&4f9;(3.E.1-•• • • 'to Aribt•I ciATP-:- :.400'f ' '''..' ....• :=hk5Irl!"rig 0...-.?..;;,„ .• ./...,,,...i.4. • ri.•:,;,4,4i,f.v...v......." .• .• ... :. .. ,,-41104%. ..8 c• • •"•••••47totf,...1/4i .... ••• ,,t. ' •• - ,;,,,;.•1 db,tifq.:kg....-- • I,. a."‘.." i 9./..•;.r4 •;•;.;".. .. e !•4:••:'''''':'7.#11.-PE?' 04 4z. F.g'c tr IV • • • - • . . " • • • • • • 777 DETOIT AVE SW ".•:• SEATTLE WA 9810 L.. DETACH TO DISPLAY CERTIFICATE—t .1, Jane L. Judd , .sUbscribed and sworn , • F625-052-003 (3-92) - . . . • -that..thas.doCumentf COpy.:of .thd . . : - iicensd..fot:MaCDonald4filleCc.%,.:on this of September 20 date 1995. RECEIVED CITY OF TUNNILA DEC: 1,..21995 PERMIT CENTER INSPECTION RECORD (-- Retain a copy with permit CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 OC (206) 431 -3670 Project: 4z� r— 0 Type of Inspect ion: ' NO Address:VaC —n CIOcVeu O -Mr DeteCaNed: Date Wanted: (� _ ' _ I 1 Special Instructions: Requester' .-J r).Q.Y r 12 Phone No.: , _ • Approved per applicable codes. 0 Corrections required prior to approval. COMMENTS: Inspector: Date: i 1(6(-'q� D $30.00 REINSPECTION FEE REQUIRED. Prior to reinspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule relnspection. Receipt No.: I Deta. 1 SPECTIO 0. G INSPECTION RECORD ' Retain a copy with permit CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 ht\ p2ag R (206) 431 -3670 Project: p llZ.•ti-ti- Type of Inspection: ou.6(1 —tr.) Address: ,..-- `-AT•V A1 4) /C- - Called: Special Instructions: Date Wanted: Z 3_c, �� am. tp. Requester: Phone No.: ® Approved per applicable codes. ❑ Corrections required prior to approval. COMMENTS: ' t Inspector: L. ❑ $30.00 REINSPECTION FEE REQUIRED. Prior to reinspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. CaII to schedule reinspection. ReoeaTb.: I Dale: G. k A k *•sl *•kA•1 A •kA',4s4k*•AA••k*A•0 •kA•kofd *•4 kA *k CITY OF TUKWILA1 WA0� k** a• AAsl* A • *k•kslA•A•A•k•4s4+A•A* *�k *s1'. Sf**A•itk•0 TRANSMIT Number: 94003346 Amount: Payment Method : CHECK Notation:' Permit No: M95-0208 Type: Parcel No: 271600 -0075 Site ;address: i.2770 GATEWAY DR This payment 58.13 To **•k4*A•k4.•k•k••k•A•* *+s. kA•k*r4** *A *4 A *k**k•k•k • r: f• ks4k.A••k1;4**A4A••k*•l k•k•A•. A•s4kstfi*A•al'ks1.A• ZlE) . TRANSMIT *A**'hA? * ' k*k*AA:1I +••k•k•ks A ks4 58.13 12/137:;x' 11:57 :57 . MACt ?ONALD MILLER knit;: ."LB E3•°MECHAN MECHANICAL PERMIT Total Fecs: 58.13 tal ALL •Pmts: .5843 Balance: .00 A * tF A .d •k .A. •k• sl * •k •k •k * A• * k si A• •h A• )4 k• •A A •A• tl * A * Account Code Description 000/345.330 PLAN -CHECK NONRES 000/322.100 MECHANIC :AL. •• NONRES Amount 11.63 46.60 GENERA TOTAL CHECK CHANGE 0775A000 58.13 58.13 58.13 0.00 15:56. CITY OF TUKWILA Address: 12770 GATEWAY DR Suite: Tenant: BOEING EMPLOYEES CREDIT UNION Type: B- MECHAN Parcel. #: 271600 -0075 Permit No: M9.5 -02013 Status: ISSUED Applied: 12/12/1995 Issued: 12/13/1995 1995 • k•k, M• k•* k• k• k•*• k* *• k• k• F• k• k* k• k* k• k• k• k.*• k• k• k• k•kk• kkk kk• kk• k• k• k• k• k• k•,I*• kk**• k• k.•F A *kkk•k•kbk•k•k•kkk•k•hF•k•k•k* Permit Conditions: 1. No changes wi 11 be made .tor;s.the;;'pl'ans.`:Uti0s, approved by the Architect or Engineer`�erii. -th °1`i��,wi"la` B �s . ul1'1,Ing;.Division. 2. All permits, ins. euti °ori records.. and:, approved = ;�aIi�n s ha 1 1 be avai table at the ; ;ab si,:.te - = =,,, t iVbr`; to <•the start of`' Hrt corti- . str'uction. Tihe'e documents ale, to.`bL plaintalned ands ".avai 1- abie until final in' p'ecti'on approve is gr *anted. ,. 3. Al 1 construct ion to be done in • confoi mance with :.appr,oved, .plans ant ,,;06 of` "the Uniform Bui1•d•ing Code (199:4 t" Edition,itia's alrientied, :Uniform" Me,6h'anlcal Code ..(]994 Edition`►°`` 'and Washington Stat.e'Energy,/;Code (1994 Edition)':, 4 . Va l i d,i , of Permit... The..' i ssuance q f;: a permit or'`''approv,a1 01 plans." ; ,pe`c.i'fications, „7.', nd coinp.0 tat ions shall not be n- ' stru,e.d ='to,. <',40, ;.:.a perinit-fir, or-an approval of any violation of a'.0. of the prov i s. i ons of..._.t,he bir i.,i.d i ng code or of a otheru' ord�ina'nce of they' °jclr,is�i;ition;' No;..ptermit presuming " to . give'.authority to .:violate'or cancel'�1,the #pr.auisior�s of tlk=is �. cod4je,, ha 1 1 be tlra l Pi,d '1 i., 5. MANUFACTURERS S = INSTA,LLATION_; IrNSTRUC`.TI`ONS-_.REOU�IRED ON SITE FOP THE B,UILDINGt..INSPE.CTORS ;REVIEW.- ..,,'..:." w, 6. Electr'ica;;l? per`.mlts:f ha11 b'e.o tain'e,d,. through the Washington. State, Divis;ion� of L.anorr ".,a'n.d' Indust i ;zar nd e;.11 electric +a�`l wor N irri 11 'cb P inspected by that agency .f'24.B- 66''30) 14 • 81 phi u r. WOG -11 A B.E -C.U- OFAILE (2EVI ON V1573.01 Jwri so B. MECHAIOGF'L ill PLUMBING 0 GAS PIPING CRYov D IN �IVIISION BUILDING EGTI 24 -0 15 14112 010 I _ • FI M O V 1 ; T! 1 iioli:i`i` u,�i�i ir Nm ', pemEt ' Ere. .e a_.:.., or . ©- {{� z u' D r Il {{: ® , INi o . ®3mie _ u Amii,f1 i I H u �e 11 -z. ----wi y_ I D I I 4yIy 2Er 21, W1.: G 10 1 -\ ti B S.5 REV15E V Ut 22 a4 <l'i< 1 ■ ® EQUIPMEUT SCHEDULE I4P 1 I Ii0121 ZON, WATER 201/02.E HEAT PUI'2Y(Q6M P1 HAKE ! MODEL CL MATEHASTER 45020 EER RATING II 7 COOL 22 104 I 28.4 40.I 746,11.9' n34 5HC SUPPLY PAN 930 20H 4 o.40' 457, %■ N P MEM 022 CoND'ENSER 4 H GPM M 9 L PR FEET 0, WATER ELECTRICAL 71)3/230- 10, 5.2 MCA 1,2 2010 WEIGHT Z4J L65. WW2. H/ O ?RO✓Ee' STAEFA CONTROLS A.CCE550R16, 1,05E . TAI.:GER KIT ILTEK ? F,EP, RACK ROTES I I 11E00 TO IGCK REVERSING 0102E IN COOLING. 72SITION 2; UNIT TO 220,,111E MARINE NON- BUILDING POURS ON, FIELC TO INTEGRATE - UNIT CONTROLS ,/ 0111001116 STAEFA SYSTEM TO ACCOMPLISH LOCK -OUT CONDENSATE PUHP ; LITTLE GIANT VCC -20145 GRAINGER 5705!5 4 32732 U GIELDn NN .' W S u�. G %IST�[14 __ I •� t,- 11 672 aR -FmOR . 4 1 „,;',477 .�'�o•CD T s ..2 _ 111111111111. ' 153137199 mil'_ / i Icon I , �i- -� � 35/169 ► I .' � b 1 �. » YOl9 ■r ■�tA�'nr�iil�. .fn�iMliYY■ 1� ■ I Y�Ile ■IIl.!�. 1 -., X \ - -.PA ,_- ' --- i I 1 27/14. a ' �3. ® I ...:. !7 AEU ME aga �■ rtui.+ �1 .- ate -ia I- [.: Iii i I2 �rr _ ®�� ®Sr°r� ©,� 67a __ �► _ i. 24.124. E ■ rrla u 4523 AGE 01.105 /,5 O LLI G 0 z O. te FIXFoRE CONNECTION SCHEDULE NO. FIXTURE COFFEE SSNK FLKAY PIPS S.TANLESF STEEL 3 HIX.E. N N q.ER�,500S,3/5 FAUCET, LK -35 STFgINE 221 19. LWAL 6IIWECT SO VENT SgSTE 11/2 1/2 COLD 1/2 a 4 a 8 INSULATE ALL DUCTS DOWNSTREAM OF THIS SYMBOL FOURTH FLOOR PLAN Scdc 1/d' = VAV TERMINAL BOX SCHEDULE SYMBOL VAV TERMINAL BOX SCHEDULE UNIT NO ENViRO -TEE MODEL NO INLET SIZE COOL MIN CFM CFM HEATER KW AT CFM VOLT /PH FAN HP MOTOR VOLT /PH NOTES I~ UNIT NO ENVIRO -TEE MODEL NO INLET S ZE COOL CFM M!N CFM KW to T HEATER I CFM VOLT /PH FAN HP MOTOR VOLT /PH NOTES 401 402 403 404 405 406 407 -408 409 410 411 4I2 412A 413 414 415 416 417 418 ;IS 420 VGq -EH -0804 VVF-E -ISBI 1-8 WF -EH- I SBII -IOA VVF -EH -iS 1 -i2 WF- EH- 15811 -12 WF -EH- I SBII -8 VVF -EH -ISBI 1-8 WF- EH- ISBII -8 WF- EH- 151311-8 WF- EH- IS13II -6 VVF -EH -1 SBI 1 -8 WF -EH- 15811 -IOA WF- EH- I S811 -10 WF-EH- I SBII -IOA WF- EH- I S811 -12 VVF -EH- ISBII -12 WF-EH- ISBI1-8 WF {H- I58II -8 VVF-EH ISBI1 -8 WF EH '4 VVF -EH- ISBII -6 8 8 10 I� I i I 1 I 535 '190 1050 l53 OO 1190 a& r) 430 490 565 5SC 85p 85C; 740 1185 M85 450 090 "45 5 S 280 125 Ia5 ' G 11 125 :15 CS 75 65 .5 100 B5 12 0 120 120 4_0 IIS n0 !00 ILO" 5.0 5.0 5.5 5.5 5.0 3.5 3.5 4,0 1.5 3.5 5.0 3.5 5.0 5.5 5.5 3.5 3.5 3.5 3.5 1.5 21 -5 22 22 25 12 c7 .=0 19 26 21 .T 22 21 at 26 , 27 24 Il 11::::) 592 b25 '.o0 100 TGO 025 416 410 425 =55 3£5 6,44- ysi 495 524 020 390 65.0 40c 375 280 277/1 460/3 460/3 46O/3 460 3 / 460/3 277/1 277/1 277/1 277/1 277/1 460/3 277/1 460/3 460/3 460/3 277/1 277/1 277/1 277/1 277/1 ..... I /15 1/4 1/2 1/2 1 2 / !/4 I/4 I/4 I/4 1/6 1/4 1/2 1/2 1/2 1/2 1/2 1/4 1/4 1/4 1/4 1/6 277/ 2. 277/ 2 277/ 2 277/ 2 277/ 2 / 277/ 2,3 277/ 2 277/ 2 277/ 2 277/ 2 277/ 2 277/ 2 277/ 2 277/ 2 277/. 2 277/ 2 277/ 2 277/ 2 277/ 2 277/ 2 277/ 2 bp,,,,, 1 A, A. t 421 422 423 424 425 426 427 428 429 430 431 432 433 434 435 436 -437 v..' SSD -II -12 SSD -11 -12 SSD -I1 -12 SSD -11 -10 SSD -11 -i 2 SSD -II -12 SSD -II -12 SSD -II -10 SSD -II -10 SSD -II -6 SSD -II -3 SSD -1! -6 SSD -II -6 SSD -11 -8 SSD -11 -8 SSD -11 -8 SSD -II -6 2 2 2 0 2 2 2 0 0 6 8 IKO H10 :EEO .,,C 7/0 1508 4, 440 930 225 420 225 2L^G 445 4, - EE.. 0 O 0 310 O O O O 14 4 4 - G - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - ;4 I,4 . 4, ZEMOVE NOTES: I. SINGLE CUCT COOLING ONLY TERMINAL UNIT - SIZE AS LISTED. FACTORY OPTIONS INCLUDE: EXTENDED DAMPER /2" DIA SHAFT. 3. A FAN POWERED TEPMINAL UNIT - SIZE AS LISTED. FACTORY OPTIONS INCLUDE; INDUCTION SOUND BAFFLE, EXTENDED DAMPER 1/2° DIA SHAFT, HEAT STAGING, AND FAN CONTROL THROUGH FACTORY WIRED RELAYS, THREE SPEED FAN SWITCH, 24V TRANSFORMER 50VA MIN RATED, AUTO RESET I30'F HIGH LIMIIT T'STAT, AND INTERLOCKED TO PREVENT HEATER OPERATION UNLESS FAN RELAY IS ACTIVATED. FACTORY INSTALLED 24V CONTROL WIRING PIGTAIL, 36" LENGTH, COLOR CODED FOR FAN (GREEN, AND HEAT (ORANGE). 460V /3PH UNITS REQUIRE 4 WIRE FEED POWER. SIZE DUCTWORK ACCORDING TO HEATING CFM. ALL MEC!,'L cQJIP TJ pE 5 ti::E _ .ZONfAL S:-AL AT STKLIC'Fur_� PLUMBING - U BING EQUIPMENT SCHEDULE Ewil -1. ELECTRIC HATER HEATER - STATE 4PV- 6- 1MS1 -, 6 GAL CRP, 1.7 KW, .120/118, 9.6 -GPH RECOVERY @ 70,F TEMP RISE, 3/4. HW & CW CONN, OPERATING WT: 110 LBS. MOUNT IN CEILING. RUN T &, POP -OFF TO NEW SINK TAIL PIECE 'GW- -a ELcOTFL 111,,NTA1YE0u51+1 'SANK -E:rA11 !)1< ".,�lCL3aN / /b� I/G 0,- TANK. xyU>TT 0.5 1,:P5, IIS v,10, N /GHn0DE PuTEID FO0GE.13 .00202 T ET- GL-"' -•,•. V64 4.v311.51AB-E "'S"/AT, MONN"("'GLO%J GOU�f'GrF�� V'4" GM CZ'1W ,21211;04. DIFFUSER /GRILLE /FIRE 13°,M'EK SCHEDULE SYMBOL MANUFACTURER It SIZE TYPE COMMENTS ❑ OA rsQ A/B KRUEGER 6500P SHOEMAKER r SERIES 600 PFG KRUEGER 1190 PERF CORE A/A 20/20 A/2 SUPPLY MIFF LAY IN PERF LAY IN RETURN EXHAUST GRILLE I~ . -,[IN HIED, SME L" fJ0T21J 'FR 011ti S12Y .I1. 0An1 "=: OUT -OF -AIr: SFRH.1'� EXHAUST FAN SCHEDULE UNIT MFR 8 MODEL 9 TYPE CFM ESP VOLT /PH HP/W RPM BDD WT /LEIS NOTES EF -1 EF -2 BROAN 366 BROAN 366 INLINE INLINE 830 980 .375 ,125 120/1 120/I 390w 39OW 1050 1050 INTEGRAL INTEGRAL 55 55 1,3,4,6 2,3,, NOTES I CONTROL W/ WALL SWITCH PROVIDED AN O N ,1114.L.1_ F2 L' E'Y ELECTRICAL CONTRACTOR. 2 . CONTROL W/ LINE VOLTAGE WALL T'STAT PROVIDED BY 0-11 AN0 I NSTAL LEO DY ELECTRICAL CONTRACTOR. MOUNT F FARR O.L. LISTED CLASS 130 30 2 THICK K FILTER RATED ON ASHRAE STD 52 -76. 3. FIELD MO 30� EF / 4 SE5 vH6L. NOTE a.H 5 1151-1, TUK-V ENH ate =T PANT ON A-2 TEMPEKAT.._�. ExG eclG G. EErOVE gU LL ISSUED FOR "CONSTRUCTION 1N� ECENED cm R of TuKwlu DEC 1 21995 PERMIT CENTER BOEING EMPLOYEES' CREDIT DATE UST 1W08792.. RPYLX:CI, DWG D- 0553 -3487 SHEET NO. TM -4