Permit M95-0214 - LINENS N THINGS
LUJNS fl41IJf, City of Tukwila �.. (206) 431 -3670 Community Development / Public Works • 6300 Southcenter Boulevard, Suite 100 • Tukwila, Washington 98188 MECHANICAL PERMIT Permit No: M95 -0214 Type: B-MECHAN Category: NRES Address: 17501 SOUTHCENTER PY Un: 400 Location: Parcel #: 262304 -9067 Contractor License No: PACAII *15482 Status: ISSUED Issued: 02/02/1996 Expires: 07/31/1996 TENANT LINENS 'N THINGS 17501 SOUTHCENTER PY, TUKWILA, WA 98188 OWNER SHIDLER /WEST FINANCE Phone: 206 624 -1444 800 5 AV STE 3500, SEATTLE.,. .WA 98104 CONTACT MIKE POWELL Phone: 310328 -6300 1327 POST AVENUE, SUITE H, TORRENCE,;CA 90501 CONTRACTOR PAC- AIRE,''INC: Phone: 206 623 -4004 10421 BURNHAM AVENUE NW, GIG HARBOR, WA 98335 ***************'*,*******,**********************'** * ** * ***.*. *. * * * * *• * ** * * ** * * *• ** Permit Descrip;Li "on:. NEW DUCTWORK,` EXHAUST FANS;,.`' HEATERS, THERMOSTATIC CONTROL'S UMC Edition: 1994 Valuation: Total Permit Fee:. 4 °0,.000.00 ''',105.00 ********************** *-, * * ** ***. * *. * ** * * **4. * * ** * ** *** ** ** ** * * * * * *: * : ** *fit* *kit* Permit Center I hereby certify .that .I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing. this work will be complied with, whether specified herein or not. The granting of this permit does not 'presure to give authority to violate or cancel,:the.provisions of any other state or local laws regulating construction or performance of work, r 1 am authorized to./'s ign for and obtain this.bu' J� /�� Signature: Date: -- 9‘ Print Name:j b_ /7e #v Title: This permit shall become`'nul'l..and void if,th,eWork °is not commenced within 180 days from the date of .issuance;, or..,` ii_ ;th`e work is suspended or abandoned for a period of 180 days froiii"tFie last inspection. RETAKE OF PREVIOUS DOCUMENT LAMS hikl 1')')Gis-oal . • - • • • .• City of Tukwila C. (206) 431 -3670 Community Development / Public Works • 6300 Southcenter Boulevard, Suite 100 • Tukwila, Washington 98188 MECHANICAL PERMIT Permit No: M95 -0214 Type: B- MECHAN Category: NRES Address: 17501 SOUTHCENTER PY Un: 400 Location: Parcel #: 262304 -9067 Contractor License No: PACAII *154B2 Status: ISSUED Issued: 02/02/1996 Expires: 07/31/1996 TENANT LINENS 'N THINGS 17501 SOUTHCENTER PY, TUKWILA, WA 98188 OWNER SHIDLER /WEST FINANCE Phone: 206 624 -1444 800 5 AV STE 3500, SEATTLE, WA 98104 CONTACT MIKE POWELL Phone: 310328 -6300 1327 POST AVENUE, SUITE H, TORRENCE, ".CA 90501 CONTRACTOR PAC- AIRE,, :INC. Phone: 206 623 -4004 10421 BURNHAM AVENUE NW, GIG.. HARBOR, WA `.9.833,5 •k** * *k * * * * * ** *fit *, * * * * ** ** *k * * *** ***4 * ** -i4.* *A•* *fir*** * * ** * * **** Permit Descri;p:t;.ion:, NEW DUCTWORK, EXHAUST FANS, `.HEATERS, THERMOSTATIC, CONTROLS.,. UMC Edition: 1 994 Valuation :. ;Total Permit Fee: 0, 000.00 ,105.00 *********.**.******.**** *** ** * * * * * *.'k *, ** ** ** * *** * *•k* k * * ** * ** **•k k * ** k ** J'. Permit Center Authorized Signa Date. I hereby ";certify :that I have read and examined this permit :. and know the same to be true and correct: All'provisions of law and ordinances governing this work will be complied with, whether specified therein or not The granting of this permit does not. presume to give authority to violate or cancel`; the provisions of any other state or local laws regulating construction or performance of ; work. I am authorized to sign for and obtain thi's2b.0 di ► p- • 't Signature: Print Name: Date: Title: This permit shall become. nu;.11..,,and void if, the.<work '`is not commenced within 180 days from the date of"° iss uancor: "iork is suspended or abandoned for a period of 180 days= >frOM• the last inspection. CITY OF TUKWi 4, Department of Community Development — Permit Center 6300 Southcenter Boulevard - #100, Tukwila, WA 98188 (206) 431 -3670 Mechanical Permit Application Tracking PLAN CHECK NUMBER m4s- o& 1 PROJECT NAME C i ni SITE ADDRESS 8501 Oo+hc n4 f j SUITE NO. goo INSTRUCTIONS TO STAFF • Contacts with applicants or requests for information should be summarized in writing by staff so that the status of the project may be ascertained at any time. • Plan corrections shall be completed and approved prior to sending to the next department. • Any conditions or requirements for the permit shall be noted in the Sierra system or summarized concisely in the form of a formal letter or memo, which will be attached to the permit. • Please fill out your section of the tracking chart completely. Where information requested is not applicable, so note by using "N /A ", date and initial. DEPARTMENTAL REVIEW "X" in box indicates which departments need to review the project. DEPARTMENT' BUILDING - initial review DATE.I AFIRE PLANNING APPROVED ! /ID '/6 (ROUTED) .1// f,- QUIREMENTS MMENT INIT: 44-^ NSULTANT: Date Sent Date Approved FIRE PROTECTION: (JSprinklers (Detectors UN /A FIRE DEPT. LETTER DATED: 1// 7/ jy INSPECTOR: s!/ INIT: / - 23Q, ZONING: G2. BAR/LAND USE CONDITIONS? [-s U SCREENING REQUIRED? [des Q No REFERENCE FILE NOS.: 1".0 -t u-4/ /195 OV o e.or- 0 OTHER BUILDING - final review BUILDING OFFICIAL INIT: 2c INIT: UMC EDITION (year): I- '16 INIT: REVIEW COMPLETED AMOUNT OWING: l a5,Ob CONTACTED ,^, ' ' rn 1 I KO . t DATE NOTIFIED _-a V W -_ `` (,� �.V BY: BY: (init.) 2nd NOTIFICATION 3RD NOTIFICATION BY: (init.) 01/07/93 Dy1 CITY OF TUKWILA Department of Community Development - Building Division 6300 Southcenter Boulevard, Tukwila WA 98188 (206) 431 -3670 MECHA::ICAL PERMIT APPLICATION PLAN CHECK NUMBER 1 APPLICATION MUST BE FILLED OUT COMPLETELY FEES (for staff use only) DESCRIPTION BASIC PERMIT FEE UNIT(S) FEE . PLAN CHECK FEE AMOUNT RCPT:.# DATE OTHER: TOTAL - SITE ADDRESS -&41E-# 0 Qic /.7S0/ 501.,`) -- c K, R--l_� . /3l�4 VALUE OF NSTRUCTION - $ K. P.44000 �N��ce,�ul.) PROJECT NAME/TENANT % 1-.. , e/v C ASSESSOR ACCOUNT # 9&,L .3c'/ - yC >6 77 TYPE OF WORK: New /Addition 0 Modifications (] Repair 0 Other: v 0 • -.7, ' )co " Sc>.- �'fif-l�' ) Lt kx. . DESCRIBE ORK TO BE DONE: OA s , 44t 04/ ) . /1/617Z) ' /'ic, aieenPSTAT? & L.S. TYPE . RATING /SIZE .' NUMBER OF: UNITS : ; C-11G i , ./ZTJ• -/ -7124da Y D J to o 2. roA., / Giwid 21-0• -2- yeaS fo•Q 2 TANS & -'' Imo /______ 3 0 --mds /w u l bVoo/Sf 30y---"o..P$ EXP. DATE BUILDING USE ((office, warehouse, etc.) 44e r'C_G?.✓ /e ._ I - '�fre.0 NATURE OF BUSINESS: ^ 3"L 4Cc ' f' /_ G WILL THERE BE A CHANGE IN USE? pNo 0 Yes IF YES, EXPLAIN: WILL THERE BE STORAGE OR USE OF FLAMMABLE, COMBUSTIBLE OR HAZARDOUS MATERIALS IN THE BUILDING? EtY'No 0 Yes I YES, EXPLAIN: PROPERTY OWNER p 3 R.,r� _ PHONE < 6 �- 686 ADDRESS'C .)C) C Auk ,- S u i `�'>;' )co " Sc>.- �'fif-l�' ) Lt kx. . PHONE ZIPcj$f�y / CONTRACTOR ADDRESS ZIP WA. ST. CONTRACTOR'S LICENSE # EXP. DATE ! HEREBY.: :CERTIFYTHAT l HAVEREAD AND; EXAMINED THIS APPLICATIONAND;KNOWTHE ,.:5-4,1E :17. AND AND t`AM AUTHORIZED 10 APPLY FOR.: THIS' PERMIT: :.. SIGNATURE /4 t 3 74 /4 : F a — /4,-,- i5 BUILDING OR OWNER .c,' "/ _ 'l/ e .y AUTHORIZED PRINT NAME /f, ? ei/_ C.J4..� AGENT DATE /?// 7' 5S� PHONE 3t,, -3. r :,•'c9 ADDRESS 3 ?7 / 7 /9e- - CONTACT PERSON CITY/ZIP.74 �Q520,52.v PH941a .24A /572 APPLICATION SUBMITTAL In order to ensure that your application is accepted for plan review, please make sure to fill out the application completely and follow the plan submittal checklist on the reverse side of this form. Application and plans must be complete in order to be accepted for plan review. BUILDING OWNER /AUTHORIZED AGENT If the applicant is other than the owner, registered architecVengineer, or contractor licens by the State of Washington, a notarized letter from the property owner authorizing the agent to submit this permit application and obtain the permit will be required as part of this submittal. VALUATION OF CONSTRUCTION The valuation is for the work covered by this permit and must be filled in by the applicant. This figure is used for budget reporting purposes only and not to calculate your fees. EXPIRATION OF PLAN REVIEW Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may extend the time for action by the applicant for a period not exceeding 1E days upon written request by the applicant as defined in Section 304(d) of the Uniform Mechanical Code (current edition). No application shall be extended more than once. If you have any questions about our process or plan submittal requirements, please contact the Department of Community Development at 431 -3670. DATE APPLICATION ACCEPTED ! a- v-q5 DATE APPLICATION EXPIRES q l� Sth3MITTAL CHECkIIST MECH . NICAL mpleted mechanical permit application (one for each structure or tenant) Two (2) sets of mechanical plans, which include: —loor plan stem layout • Elevations (for roof mounted equipment) Feat Loss Calculations Structural calculations stamped by a Washington State licensed engineer may be required if structural work is to be done (2 sets) Note: Hood and duct sysiems require a building permit for the duct shaft. Water heaters and vents are included in the UMC — please include any water heaters or vents being installed or replaced. • • r • �.r..,. ,.•r,Y. •!•.1' 1i' t-.. ' .'t � 41 7I'., %' ' :,. :n7', t.°CC!!��Q( ..Ia ; li Y .''�.nF' r•�t•1`..:.!•? P•�:...(. ''7d: r}1'r .s. .yr;, t.. .q.. .' • ,; ., : ^'• •' ;: +�,:. 'J'• °.r.L4• .. T //� ',Vt r.�< ,:r,�: 1 :1;..rl,,T"i,•;•I .. v ;i .l'J.!..lf "• ui.. n.t; •° is l :.:t`%'.. ° r r . ,4 _.'..tr L�; j[,, :LoN::. .AT{C.. ,' .. ".•'1. .. `r•.... �.. :•t ;•:VI,. i '.....y..r� ,t,., • Yr� {.irr'�,,�y NNei. J J''' ,'1 rtw•. ,{r,1. �¢. ,• .,•` '.�• ,''{( .L' 1'f, r a . ^�• /iiJ.•. :, t�;sr;.t '!'. .,':�� t. i.. •F .t ��r �!'•l�ai �' .��,�' •'�i N�� i.��l. iYj SF. fi '1 .i;s` a, 1. .: c `;r ' • t '•a..'7I :�;�i�; / •1 7•;r 1} fI'k''' Li: / •%�4 ;,�Y �'•,!. Ir' •1 I t •i'til i. 1 I� n 1 ltf•e'�;a •�; /,�.�,` °r•!:'i:,,.'. C�,�•Y• r ..: INSPECTION RECORD Retain a copy with permit INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 981 ( V ci Lr4: PERMIT NO. (206) 431 -3670 Project: (r ! f � J 3 .4---\-\ 1463 Type of inspection: Ate\ Address: Ili Date called: Special instructions: Date wanted: `t L` q ( - -,8.m. Requester: Phone No.: Approved per applicable codes. Corrections required prior to approval. Inspector. �_ Date: A c t `i'• f 642.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. 11 Receipt No.: Date: e. 4 • re.) INSPECTION NO. INSPECTION RECORD Retain a copy with permit CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 PERMIT NO, (206) 431-3670 Project: i Z---/ 1'41.1 "4 /-I iN16 S Type of ins action: lk E - Date called: 3/12 Address: (.- --) . C . p007 Special instructions: i .9 IA -r-4.1 (/- /4-t 6 A--as ---- &ILA r V A k.c77-10i Date wanted: / .3 a.rn.\ Requester: Phone No.: W....Approved per applicable codes. Corrections required prior to approval. COMMENTS: Date: ,p21 (11 $42.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. IReceipt No,: .•111•Mil■••■••• Date: C? INSPECTION NO, INSPECTION RECORD 'Retain a copy with permit CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 Aps-o2.14/ PERMIT NO. (206) 431 670 Project:4_., c 7---/ >9) Type of inspection: ';'? 4V110 04) Address: j--7?)/ Sf-', Date called: isecia ins: Date wanted:3 ...7,94 i3 Requester: e"-- 7 -.°P--si i 0 iit is iii,e,/ Phone No.: Approved per applicable codes. Corrections required prior to approval. COMMENTS: / ';'? 4V110 04) ------C.4-Z6----Qded/dP (7 i c--( C., C...31— L4-1442.-- /_i S C4&- /IL 3 0 e"-- 7 -.°P--si i 0 iit is iii,e,/ i<--Ld.e CE)fr, 45 ci.,L.- P-2..,249 1-1e_, 1411,4441 30 /1 C-'417 Cengetate ,le ir\ Inspector: NA-4AI I $42.00 REINSPECTION v EE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Date: Receipt No.: Date: City of Tukwila Fire Department Project Name Address John W. Rants, Mayor TUKWILA FIRE. DEPARTMENT FINAL APPROVAL FORM cat Rs- 'N T4;11 s /) S o ) So tA.'(tl IP! Retain current inspection schedule Needs shift inspection Thomas P. Keefe, Fire Chief Permit No. 44 ! `O,-/ Suite # LOO ,j_ Approved without correction notice Approved with correction notice issued Sprinklers: Fire Alarm: Hood & Duct: Halon: Monitor: Pre -Fire: Permits: isorit,„ P6147 Authorized Signature Date FINALAPP.FRM T.F.D. Form F.P. 85. Headquarters Station: 444 Andover Park East • Tukwila, Washington .98188 • Plane: (206) 575-4404 .. Fax (206) 575.4434 k*ic*+*a***+alc«+ia+a*++:$+A+A******++A+akalc+*A+*Ii***a+sl***+ CITY OF TUKWILA, WA ++A**A+AAa*A**+*A f+**J�AA�\ +A A • . *a*0 AAA A**a++A+a*+A*x+x*++* � TRANSMIT NuMbep: 96003371 Amount::::,,,, 105.00 02/02 Payment Method: CHECK Notation: PAC-AIRE INC. I V1..8�43 TRANSMIT + ��. ~ . �`~- �� ^ ,~' . ~. • .....� ~~.^~-~ •~..~-_ -`-^~''`-- - .^ ~-- -~^ -- - ~ '-� -~ ''' ' � � Permit M0: N95'0214'' Typg: H-MECHAH MECHANICAL PERMIT Parcel No: 262304-9087 ' ' Site Address: 17501SOUTHC|NTCR PY St: Fl: � Un:� 400 , Tutal rees: 10;:l"00 This Payment 105.00 Total ALL hots: 105,00 ` DalanLe: .00 A+*+***0*+A**A+** +*A***+4***+*+A*+*+*+*+a*^*a+*k*****++ira**+*+ Account Code Description ' ` Amount 000/340.830 PLAN HECK~ NO'EG� ' 31.00' ` ^ 000/322,100 MECHANICAL - j ONRES �` � 84.00 GENERA 21"00 GENERA 84.00 TOTAL 105.00 CHECK 105.00 CHANCE 0"00 2274A000 16:49 CITY OF TUKWILA Address: 17501 SOUTHCENTER PY Un: 400 Permit No: M95-0214 Suite: Tenant: LINENS 'N THINGS Status: ISSUED Type: B-MECHAN : , ' ,. ,;. ..-',. . - ....iPp p l, e d : 12 / 18/ 19. 95 Parcel #:.262304-9067 11ed: 02/02/1996 *************4***4*****4****************.k******4.**A**************** *A*.4*** Permit Condition:, 1 No Changes will be ma d e,t0%V4.j#1 ,Lytes p p ro v e d by the Archi tect or Eng i neer0netheTu kw i fe-EitTOtntji v i s i on . 2. A 1 1 perm' ts. , pe:CtICK''reccrdsi, an cl!, approved,q,pil'ans s ha 1 1 • be .,„,. ,, • , .• a v a i lab 1 e at tli:e..1.6b s i•-it e',:.:.pr f p t i tb (.t1) e s t a t ,... a f ''enki,,,co 'n s eruct ton. These' document re .to' be ma in,t al'ned int-(.4,va i 1 - able . un t i 1 ..14nel in ip:.ect fon '' approval i '.--... 1,3tia'ilied .,.:, '''':j..i., ..'.- ..:.:1,,\,, 3. A l l cons ty(49.t i on t�. done ::.iti conformance with ,*APP.toveW:!.,,:, pl'allS and ;i2.4c0 r 6..910 ts of 'the 1.1nif. orm Bui 1 '6i,ng CCO e (1 91,i , 4 E d i t i ortX;%. ta's amended, ,,,Uni f o r m-1;1.6' .1,1 a nj cal Code A1994 . Ea it i CnY,',\ and Wa11til g t on 5 t a te Energy .Code (1:994 E d i t i on )'.., "":„.:4'. 4. Validity of' fey. m i t% The,.,j uOnce qf' a p e rm i t or 'a p P rOal 6'11 A p 1 a nsre',sp eoft i cat ions , ::',.`:: and cCliip,‘.tt,at i ons s ha 1 I no t be !con- ' '..#'4, v, il S t r used1 to. be "tt permit ' f:Cr , organ' approval of , any violation ,f:'! of anii, of the provisidn's-of-,the butlidIng code or of any ,,i.'1,,,,,, o t h e'r",?tir &than c e of the:-"-:f to, r i S di ot i on: '% >N6:%, perm i t p re Um thr to Izilrl. ' g i v:iauthority to .violate 'ort'can,..00:'ittie ipr.c,ii s i on s of tlyrii'''t,, \ code he 1 1 be ,";±,raTi.t.L . 1,k,k '.,': 5. MAN6FACTURERS ;INS TALiATION: !INSTRUCTIONS-REQUIRED ON SITE:- i1 .' FORT`HE BUILDING e.INspg.c"..T.oki-figviEwl%, .trf .---- ,I - %.., ,: ,:-I ...— .; 6. P 1 uki! 61 n g il, or m its t riyi v bf Jo ,t.;eal no d'.„tfli ro.ug. h sithe S e a t t ye -1:::, W.0 hi Co u i i k i Department . ' - of 4?.y1.)t,:16' Healtp ./;',--,f±.144141•ng,‘ w i 1 1 b e', • et i ' .r.1,, l i n S R0t 0 '',1? 4 that a g en cy , i tic 1 ud i‘ng .,. all .,g`.61 s-p IR i n g . (29644\722,W' k - . ati,f. 0 ,., . A 0 '''''WVkt51.„ ., 7 . E 1 edtif%tcal:,, "Pec-ti.m Its • s ha 1 I be ob t.a i6d „tfir61#qh'Ilte We't...h j,_.-tigrtili i work in be i nspeqed by that a/gencli, 248-166'39J: . Stateki‘v ts.j di •of'''Labor. and Indusfr tes li d re:1,M e lei; t r ili7K 8 . Reads 1 y‘,0p..c. e ,s. sip 1 e access to roefi mo.uiii 0 4„equ 1 pment 4: k rft.so' required • ,. !'e `t? ■'■1 Oi 'e) C'f ''. "‘ - .fii.' ''-0,'V,1::', r;.' -q • •, 'f : '''''■;:Zist.',;.-..„. ..-!..,,,,) ‘..7‘...;.'4•1/4 . ,,e) 4 !.tad 4 • ''''' ".4 . . City of Tukwila Fire Department Fire Department Review Control #M95 -0214 (511) John W. Rants, Mayor Thomas P. Keefe, File Chief • January 17, 1996 Re: Linens 'N Things - 17501 Southcenter Parkway, Suite #400 Dear Sir: The attached set of building plans have been reviewed by The Fire Prevention Bureau and are acceptable with the following concerns: 1. H.V.A.C. units rated at 2,000 cfm require auto - shutdown devices. These devices shall be separately zoned in the alarm panel and local U.L. central station supervision is required. (City Ordinance #1742) H.V.A.C. systems supplying air in excess of 2,000 cubic feet per minute to enclosed spaces within buildings shall be equipped with an automatic shutoff. Automatic shutoff shall be accomplished by interrupting the power source of the air- moving equipment upon detection of smoke in the main supply -air duct served by such equipment. Smoke detectors shall be labeled by an approved agency for air -duct installation and shall be installed in accordance with the manufacturer's installation instructions. (UMC 608) The installation of wiring and equipment shall be in accordance with N.F.P.A. 70, Article 760, Fire Protective Signaling Systems. (NFPA 72 -1- 5.5.4) Duct smoke detectors shall be capable of being reset from the alarm panel. (City Ordinance #1742) Remote indicator lights are required on all above ceiling smoke detectors. (City Ordinance #1742) Headquarters Station: 444 Andover Park East • Tukwila, Washington 98188 • Phone: (206) 575 -4404 • Fax (206) 575-4439 City of Tukwila John W. Rants, Mayor Fire Department Thomas P. Keefe, Fire Chief Page number 2 When the control panel is located inside a room, the door to the room shall have a sign with one -inch letters which reads "Fire Alarm" or "Fire Alarm Control ". (City Ordinance #1742) 2. All new fire alarm systems or modifications to existing systems shall have the written approval of The Tukwila Fire Prevention Bureau. No work shall commence until a fire department permit has been obtained. (City Ordinance #1742) (UFC 1001.3) Contact The Tukwila Fire Prevention Bureau to witness all required inspections and tests. (UFC 10.502) (City Ordinance #1742) Any overlooked hazardous condition and /or violation of the adopted Fire or Building Codes does not imply approval of such condition or violation. Yours truly, The Tukwila Fire Prevention Bureau cc: TFD file ncd Headquarters Station: 444 Andover Park East TukwU�, Washington' 48188:. Phone (206) 57$4404 • Faro (206)575-4439 CITY OF TUKWILA Id: ROUT130 Keyword: UACT User: 1677 Activity document routing maintenance. MECHANICAL PERMIT Permit No: M95 -0214 Tenant: LINENS 'N THINGS Status: PENDING Address: 17501 SOUTHCENTER PY Route: 1 Current Route Line: 2 of 6 Packet Units Description Station Status Received Assigned Complete aaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaa Packet Units Action Station Initials Status Received Assigned Completed MECH 01 01 C BLDG KEN Ap Cond. 12/18/95 01/10/96 01/10/96 Priority (0 /low..9 /high): 0 Regular hours (HH.MM): .00 Overtime Hours(HH.MM): Comments 1[H.V.A.0 WITH AUTO SHUT -OFF ] 2[ l 3[FIRE PLEASE REVIEW AND COMMENT. by KEN ] 4[ ] 5[ l 6[ l 7[ 8[ l 9[ 10[ ] aaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaa • f+. �r��r ..�.wMMndxvea- ..e�fw.ae,rrc'n Mv��a�V�nrvwvanfr ..rw�.f.nwn.�tvh'.WW.n + � 01/10/96 l F1 =Help, ESC =Exit current screen. DIVISION OF WORK - SHELL WORK DIIIISION OF WORK - TENANT SRO W _� -� �: 5 erg..` / CAmin=B:•IM 6 06D1lO I R)4 60. iW11i■■ ii■■ NIIIIOIIINII NAM= .I NI rmum E �ML SAES r K__ 1€11•Mlim �"+L HMTERIM. 1(111111111111ILIIIMINNI - A10 BEAMS E111=� HEE MIN En . X11311 =1 oram11♦101 ��11 i::1MI1111111111 • 1 h Ate. i.■ PER TENANT'S SPCC.. • p■rd SIlA11M tI__ WA MUM STN,>G71RUL 114• 11E11111111♦ ms C -:- :• -;._ "'emu i�-3.':�������� MTh - i::f__16I-__- E 1•11•EM MEM VAPOR RETARDS* AN HIILTRATION BARSUE Rt WILLAT1ON moon NV RES OMMOUTION 4 OISPOBi1L OF MATIERLAL A VIEMENT 6 DEPOSAL Cr 14511. CLEAN AIR CERTIFICATES Garman. 6.1BROR) FNSI4 FLOOR PROTECTION NMERNIEB>e1 Mil Mill MI= 514400 ODORS 4 PRA.:. TRAP PK/ Nr.T DOORS RLNA6Q0 FRE SKITTERS 51M41 HARD55RE PAN. NNmSWE c*5 446 tACQeTIGAt TUB PARTED 44 PAWNS !WOW. 1 BABE CARPET vol. 6 TRMCit'ION STRIPS MEGA T1LE CONPIETE SEALER ADHESIVE TOW AC.GCOORES INTERIOR 3164104E 4 144Pf6G5 PRE ALARM PANES I COLIWIEHT TZ9.1Sf44HE SYSTEMS PAWS/ M{SHC SYSTEM SEGO., SYSTEM •COHEN. 510051 BAWER ExTERIOR 5164.6E ROOF 440651 DOOR GOLL3K DOOM 4 0RB44.6 PLNOPE RATORB STC EPROR'T 6 VESTEILLE PRATE 6 6142546 AUTOMATIC DOORS 4 SENSORS D0OIR FORDVONSE PEATME RSTRIPPINS 4 THRESHOLDS MORDER 44YS MACHN E PLDO SKIS AREA MOMS SHOW". CARTS 54.13 AREA FIXTURES WOOD 4 HETAIJ STOCK AREA FIXTURES O10O12 6 1EETALJ BABY C.TN4f61116 STATIONS OFFICE RAEBEIBE LAVOENE kO, Ik4 'it 7 1,11■1167,11016krall4h, *01 BUILDING CODE DATA TYPE APPLICABLE GODS NRE FR,,.... N 1WOlo4 FRE COO4 - 1114 MITIUI MV ANY LOCAL AMMEMBERES FP APPLICABLE BUILD." APO MILD., CODE - 5514 aDTT10N 450 ANY LOCAL M6914105 5tf6 0 AITLICA5LE PLUMS. 4 FLOOD* GS - 1941 ®ITION L40.00164 OD NV ANY LOCAL AMEN OMENTS 5 ,!PPLIGABLE MECHANICAL UNIFORM MEG44WCAI. CODE - 1944 EDITION AND ARC LOCAL. AMMENO ENTS P APPLICABLE 6EC71bGK NATIONAL ELECTRIC/U. GOOF - 1943 PDITICE AND ANC LOCAL AH MINDSE T5 IF APPLICABLE HANDICAPPED 1.4ACCESSUSILTY GODS, CHAPTER 11 AND ANY LOCAL AS.E1/ t 0{15 IP APPLICABLE CATEGORY REDUIREMENT CODE REFERENCE REMARKS G0111111:TIGTN TYPE TYPE V-N SPRINKLES= SECTION 1401 SPRnKL[3SZD OCCUPANCY 15-3 SECTOR /O RETAIL STORE OGC PANT LOAD TOTAL OCGLPART5 1.30 (RETAIL SALES) TABLE 39-A SEE BELL. 1.900 (STOCKROOM) TAME SS -A SEE BELOW 269 / 100. 3 5AP6TRAP -: .. SEE BEILYY OUT ?4 TN 02 Ethos par OCCUPANT °E5 TION 9309 Ilo) NON STAB:MAY EXITS Meet OF Ex TS 4 SECTION 9309 (a) SEATER WE t001 OCQPANT' D15TANCE TO DDT 200 foot SP.GTIOt( 9905 -(d) SPRINKLES= BUILDII6 Ara a = _DT!! - 44 PoPoo SECTION 9305 (b) GREATER THAN 550 OCOPANTS FIXTURE RAMS GLASS C CHAPTER 42 (100.0%) FINISH RATIN GLASS 111 - PALLS CHAPTER 42 CLA55 11 - FLOORS • CHAPTER 42 f OCCUPANCY CALCULATIONS OCOFARTS REGUINED WIDTH SALES AREA 46420 sf (9099%) 1,30 (RETAIL SALES) 06,420 / 30 • 1214 STOCK AREA 2004 of (6.49%) 1:900 (STOCKROOM) 2604 / 300 = 4 OFFICE 261 N (069%) 1,100 (OFFICES) 269 / 100. 3 5AP6TRAP -: .. BREAK ROOM 312 if (0.9696) 1,15 (101044) 512 / 15 • 21 LOU) TOLET ROOMS 310 N (0.1146) 1,100 (OTHER) 510 1 100 • 3 EgCT51A CORRIDOR 100 of (0.45%) '1,100 (OTHER) 1E01100 = 2 BOB 6RE6 1 TOTAL 90.095 or (100.0%) - 1252 occupants EXIT CALCULATIONS OCOFARTS REGUINED WIDTH REQUIRED RAVER 1232 1,252 X 2 Eshos /o0CUpent • 250.4 Inc644 (21.0 feat) 4 (441401t load > 1000) M1DT14 PRCNIDED NUMBER PROVIDED 6 feat • 6 feat • 6 feat • 3 feat • 3 foot • 24 Net 5 oxlt door loc./Ions ARCHITECTURAL A001 TITLE SHEET A002 GENERAL NOTES 4 SPECIFICATIONS A005 GENERAL NOTES, LEGEND, 4 ASBREVIATIONS AI0) ARGH)TEGTURAL FLOOR PLAN A102 ARCHITECTURAL FIXTURE LOCATION PLAN A103 ARCHITECTURAL FLOOR FINISH PLAN A201 EXTERIOR ELEVATIONS AND 516N DETAILS A501 INTERIOR ELEVATIONS A401 ARCHITECTURAL REFLECTED CEILING PLAN A701 ARCHITECTURAL BILAR6ED PLANS, ELEVATIONS AND DETAILS ATO2 ARGHIT2GTURAL DETAILS A801 -.DOOR AND FINISH SCHEDULES s PLUMBING P10) PLUMBING FLOOR PLAN P10) PLUMBING DETAILS AND SPECIFICATIONS MECHANICAL (4401 MECHANICAL HVAG PLAN M101 MECHANICAL SCHEDULES AND DETAILS M801 MECHANICAL DETAILS AND SPECIFICATIONS M8O2 BUILDM6 AUTOMATION DIAGRAMS ELECTRICAL EIOI ELECTRICAL POWER PLAN E401 ELECTRICAL LIGHTING PLAN ETON LIGHTING, SCHEDULES AND NOTES 2702 ELECTRICAL SCHEDULES AND DETAILS E7O3 ELECTRICAL DETAILS 0801 Fl Fr,TRIGAL NOTES, SPECIFICATIONS, DESIGN CRITERIA, ABBREVIATIONS 4 LEGEND FP401 FP801 FIRE PROTECTION FIRE PROTECTION PLAN FIRE ALARM SYSTEM SPECIFICATIONS 4 FIRE SPRINKLER DE-516N NOTES FIXTURE FI0I MERCHANDISING FIXTURE PLAN F)02 INTERIOR SIGNAGE PLAN FI00 INTERIOR SI0NAGE DETAILS F10) FIXTURE DETAILS FIXTURE HANDBOOK (DATED 1/24/45) M°15-6.14 LATEST REVISION MGM OED 45 PEG .6 /RG 45 DECD /DEGo 'I PEG VS LEC 15 DOG 45 1 P 49 NAME .1 Dec 15 ADDRESS STARE ADDRESS NAME ADDRESS CONTACT PHONE FAX LINENS 'N THINGS 11501 SOUTH CENTER PARKWAY TUKUILA, WA ROY 22)04014 (206) 682 -6868 (206) 682 -1040 ANT ARCWTE TURAL NA 1 MR 43 1 DEG 43 , DEG43 T PlG 45 1DeC 45 1 ECG MI T DEG 43 IDOL 45 ,LEG 45 , DEG 95 DEG 4D DEG 95 1 DEG 13 csG 45 1 MG 95 T DG 43 DEG95 DEG45 14 KY 44 VENDOR LIST CATEGORY CONTACTS TELEPHONE 6RILI45 4 scwrOsS DREOTO 126 RR4LIMS5 TERROR! CONCEIT 4 RAN. 31R3455 PTLON 51614 201 (800) 694 -6032 (415) 455 -5335 (2O) 392 -5814 40001EC W*04L roe PROTEcilok .44114KLERS 014'ICE BREAK ROOM TOILET ROOMS KAMM IMMO= FT -TT "7T4]F i111111I1M imismo RFC. fl€1111111111111•11111M_i;I R M w iat .._:auR ® ®E':�����GTRR7-.'•. f AMIN 1€:11 ®IMiONlMNI ? a. 7:IM 1111111111111111€111111111111M 11•11=MMINIIIIIM fE311111111�LA®i�' _ "T' 111111111111111111111111•11111(1111111Mi ®11111111111111111101 111111NESEIN 111s11I {1EVI .IA.STORE CLOSET FRRE ALARM 5157444 4 PATEi- 3401M DETECTORS CAPITOL L16HT DANK DE: DISPLAY WOOER T1644T 24 -1290 (312) 521 -5620 (800) 622 -4264 TOOK DISPLAYS GASWIRAPSMILLMORK HORI4 4 5111R0l45 SHOP ORAWN55 SLATER METER PLUMB926 ill FIXTURES DRINKS. F444514IIS. TOILET ROOM MOWED *H O S'S CLOSET VW 1NAG TA5TPDRK 4 DOWNS SSW a HAWr.O'E551 SYSTEM LR8T WATERS THE FRAME GOHPANY LESIOX J 6 .I CARPET PLEA RISERS - WNAG" CARPET Tc• LARRY' DON TERPIN DAVID' TONY (201) 489 -3836 .(203) 7956011 (40O) 241 -4566 VENDOR CATEGORY CONTACTS TELEPHONE 6 t - DISPLAY - DELORES (201) 411-1100 METRO DOOR 6dRILI.0 LISA (800) 669 -3669 1212) 136 -3858 MRDTG56N EXTERTORS+FINA6E SR/56 PAM RNTERSATIONTL tm #J4 LADDER POCKS LADDERS TEREEA WARREN (BOO) 524 -1214 (212) 226 -514/ 5AP6TRAP -: .. BABY SEAT /GNAN*E STATION ARNOLD (203) 846 -6129 SERVICE LEEK .PRODUCT LIGHT FIXTURE LOU) (201) 4/2 -1500 U6TED STEEL 4 PERE DARTS ARNOLD (209) 646 -6729. EgCT51A INTERIOR 41614A6E LARRY (316) 585 -5651 INIECENBAC44 BROTH 2ELL LM•P5 GASHPIRAP3/MLLPORK BOB 6RE6 (414) 239 -4500 (711) 244 -7661 FRUU. TEST AHD - R�lA'RT 1111111IE3t1•LUM MIK ANN MINE MIN 11111111 11111=-3=211111.111111111•111■1111111L11■111111111111€111=11777 'Am - a _10i 1111111KAIM ®- 111111 1r■�s 1 111111 ganninigMBININBNYBEMI BIBINNISSEI RORIBBIBIBIG Dl5C4NIrGT SPRIG$ STEP-0.2461 TRAte 4R't Sts CONTACT PHONE FAX NAME ADDRESS CONTACT PHONE FAX LINENS N THINGS ONE THEALL ROAD RYE, NEW YORK 10500 JORGE GARCIA (914) 425 -4245 (414) 925 -4006 CONS RUCTION MA : E R LINENS 'N THINGS 4254 E. DESERT MARIGOLD CAVE GREEK, AZ 02331 JOHN HAYS (602) 502 -4414 (602) 502 -2446 TENANT PURCHASING DEPARTNECT NAME ADDRESS CONTACT PHONE FAX LINENS 'N THINGS - PURCHASING ONE THEALL R0A17 RYE, NEW YORK 10500 KAREN McKENNA (414) 425 -4142 (414) 425 -4001 LANDLORD NAME ADDRESS CONTACT PHONE FAX PROJECT NO 43)41 DATE. 12/1/45 DRAWN BY- 0/0/5 STORE NUMBER. 0464 SCALE. AS NOTED FILE. LTA001.04 f6 INIMMIREMENEEMI Woes AREA 400154 SALES AREA 36,4204 STOCK AREA 26044 OFFICE AREA 2644 BREAK ROT 3124 TO1.ET /CORRCOR 4404 REVISIT. QI CITY REOLESTED INFO. DEC. 14, 1945 P3 PARTNERSHIP 800 5TH AVENUE, SUITE 3100- SEATTLE, WA 48104 -3122 ROY SENNON- (206) 682 -6068 (206) 682 -1040 BUILDS DEPARTMENT NAME ADDRESS L ...and that the Plan Check approvals are , rrors and omissions and as royal siithorize the violation of any code ordnance. Receipt f con scup .41)pprov -d plans acknavledged. CD, CITY OF TUKY4ILA - BUILDING DEPARTMENT 6300 SOUTHGENTER BLVD., SUITE 100 TUKAILA, N1A 48188 CONTACT PHONE (206)431 -3670 FAX NAME ADDRESS (206) VE A - CT n PERMIT - iffi.*6 18�I�D PUP. .Qn s,�;{pICAL �P' MBING PIPING civ DW 10 Butum&G CALVIN J. COATSWORTH, AIA 2450. DUPONT DRIVE IRVINE, GA 42115 CONTACT CALVIN J. GOATSWORTH, AIA PHONE (1)4) 833 -1430 FAX (714) 303 -1140 FIANXPENGIRE NAME ADDRESS NrC4B4TAGtB PD.S. (046HiRApS) RATER HEATER UNIT 7E1TE45 LLTA451.. LIMA 4 ASSOCIATES 8642 BEACH BLVD, SUITE 200 BUENA PARK, GA 40620 - CONTACT MIKE LIMA PHONE (114) 521 -3662 PA7f (114) 326 -6130 e/ $0'1 APFR NAND LIMA 4 ASSOCIATES APOPIESS S5 BEAGI4 EPA,- WM' 2©0 A PARK, CA 10620 1. RDOFTOF AIR CONDITION uY3 A49 LieSr. , FEr..D vHRrtY ExACT pit£ ANO LOCATION PROR D.GTYRA. REH.t_Am.E AR FOR EXY. ,S P' KNITS AS RE... .ROIL -D `i.ent"YS A PROPOSAL, NR CONTRACTOR SHAD ViSlr TnE Sit MO TMOROUYCr INSPECT ALL EXS,No CONE,,043 -O E MAT '1E ACM< REFRESENILO ON Tye ORMeNes9 AND 94 NESE _ _...F,CATL71b CAN OE NSTA.. E, A5 NOOATED. RROJCS FROF9R AGT TRANSFOR,,NON FOR ACM), HVAG UNITS NSTAL:,ED. A- RRCIOt 4.999 RY /MAO VANES. SPUTTER DAMPERS V0.L4•! EXTRACTORS Nm OhlERR FEARP95 N�f' ED FOR A 9M00TM ANO LONT401J10 F1,On OF NR 5. CCORONATE AGNAL LDGAT1ONS OF OMSERi, R9616TERS 6RIL1.95 YON C913.3. DETNLS MO OTHER EA,..R. AS Loy,. flXTURES E7G. TMAT MM AMC, t - ACEMENT OF NVAO 5791194 CLAVONERS. AC,Pnr ARO,EOT OF ANY DSGTEPATGE:S iMI.IEOIAT'E.Y. MECHANICAL NOTES HVAC PLAN' A 2,6 ID,WOUS, OUGT tP TiRJ h' ROOK., -� 0 =4 TO S 10051 4 5 BREAK K 010 1 FF 011 MT FOR 9) 6A5 UNIT HEATER MANJFACTURER RF_ZNOR OR Ea), MOOEL. FE -250 INPUT 250,000 BNMR ELECT: 115V /t0 /60HZ 53FLA 1/6 HP CORRIDOR K 13119R IIMINIM1919 119/11119111GWII OMR H 1941MGiONIMUNIRA r/IFciE III Cs MIS cif uii`` 96•Xlb¶ ` -MeV, 1 1 t �.. -. 4. t t �� } -!i •. �.� tlfNN MINI[7NIIIRr FH!• p1111199•31=99lA•111IMI RI/MoRONN/111111111113iiIMIMt]i ra11011111911•1111.ca•11111•ria■•r1a MR11111 20•x12 ;TYT+FOR 6, 1 _1y I stlINIM9aNF3s 11111110 ;; I= NINIX/• 100.Wi411101iN tafR, _aT� Rarer+:, EXISTING j -- ON ROOF - ROOM' W - . ... H�EfI�iC��.�.�lH�Y'i>b>i!•tE`1� STOCK AREA oovi trYP FOR 160 5/r SALES AREA 10021 '-.'1,111_:.,.._ _ ,- 10.0 RETURN AIR TRANSFER GRILLE n (i5 - ba VESTIBULE pECO CITY OF TENUEKWIUI DEC 1- 8 1995 PERMIT CENTER immtwamisra ail?, m d, y Nu O - 3 5 O U PROJECT NO. - 95141. DATE, _12/7/95 DRAWN BY. :- ES STORE NUMBER, -_ :0469 SCALE= . AS NOTED FILE, LT0469L.DW6 GROSS AREA- 401095',0 SALES AREA". , 36,420* STOCK. AREA -- 2,6.04* OFFICE AREA = �26a* BREAK ROOM 3)2+,0 TOILET /CORRIDOR 490* REVISIONS ': SHEET TITLE, HVAC PLAN oes,EA4 AREA avrER OUT VE I H.MMER M OE HUNTER OUTSIDE WIRER INSIDE 9b ! No ! Db % HMIDITY Pb Db % MJMIDITY SAE= P LOGR 65 1 68 j 75 50 22 72 WA S:OG:R.r.OM 35 bB i 75 50 22 12 WA 0E'Ir C U LtTVGH ROOM 85 68 I 75 50 22 72 WA I!9 ! AIR CONDITIONING DESIGN DATA 51113°L MODEL NO GFM S.P. WATTS VOLTAGE REMARKS MARK EF -U GOOK GYMINI 5-15 500 5'15^ 155 115V. Im TOILET ROOM EXHAUST EF-3 COOK LITTLE GEM -NH 100 OS° 115 IISV. 14, JAN. ROOM EXHAUST ..—.. FAN SHALL BE FURNISHED WITH SAGKDRAFT DAMPER EXHAUST FAN SCHEDULE ID. KNIKIN TOTAL MINIMM SENSIELE AMBIENT COL EAT AIRFLOW EXT. S.P. MAX VOLTS/ UNIT TOTAL HEATING CAP. MEN GAP. (BTIM) CAP. (31tH) TEMP Cr) (CFM) (IN. WC) H.P. PHASE MAWFACTURER 6 MODEL NO. REMARKS TA$ °F 4P °F wb MCA FUSE INPUT OUTPUT RTU-! - - - - - - - - - - - - - TRANE YGD360 EXISTING MU-2 - - - - - - - - - - - - - TRANE YCD3b0 EXISTING RTU3 _ _ - - - - - _ _ _ - _ - TRANE YGD300134 EXISTING R1V-4 - - - - - - - - - - - - - TRANE YGD30054 EXISTING I THIS 6 THE STATIC PRESSURE EXTERNAL TO THE UNIT. IT DOES NOT INCLUDE COIL, CASING, FILTER OR HEATER LOSSES. 2 PROVIDE UNIT NOM ENTHALPY CONTROLLED ECONOMIZER SYSTEM, POPES EXHAUST FAN RELIEF. 3. PROVIDE SHOD DETECTOR IN THE SUPPLY AIR DUCT FOR EACH UNIT. SMOKE DETECTOR SHALL SR)T DONCN THE SUPPLY FAN WHEN ACTIVATED. 4. ThE UNITS SHALL HE MSTN, ON ROOF NTH FACTORY CURB. 5. ECONOMIZER 4 SMOKE DETECTORS NOT REQUIRED ON RTU-I. EXISTING AIR CONDITIONING UNIT SCHEDULE W-. WA! m�oP mommieurrion gUCg • DESCRIPTION MAN)FACTURER MARK _ MODEL No. ® 5110E4ALI., DOUBLE DEFLECTION, AIR FOIL BLADE, SUPPLY REGISTER WITH OPPOSED BLADE DAMPER TITUS 300 RL - PERFORATED SUPPLY DIFFUSER WITH FORWAY PATTERN CONTROLLED AND OPPOSED BLADE DAMPER TITUS P55 AA PERFORATED FACE CEILING RETURN AIR GRILLE TINS PAR / SIDEWALL RETURN AIR TRANSFER GRILLE TITUS 35ORL CONCENTRIC SUPPLY/RETURN DIFFUSER GAN FAB /GF4850DJ036 -72 ADAPTOR GROUP CONGEdTRIG 51PPLY / RETURN DIFFUSER CAN FAR /GF4850DJ08 -09. ADAPTOR GROUP EM LINED SUPPLY A'RH GT ROOF STRUCTURE LINED RETURN AIR DUCT N' i ROOF • I /2' MESH. MIRE. SCREEN AT RETURN AIR DUCT OPENING. SEE FLOOR PLAN FOR DIMENSIONS NOTE: ALL DUGTNORK SHALL BE INSTALLED TIGHT TO UNDERSIDE OF ROOF STRUCTURE SECTION (RIU -45•b AND RTU -II) AIR DISTRIBUTION SCHEDULE MRF. M MODEL NO R FURNISHED EY I INSTALLED BY REMARKS TENANT b bt. T TENANT M MECH. RTU- -I THRU RTU-4 T TRANE S SEE SOH. - • • • • E EXISTING ON ROOF EF- I,EF -2 W WREN GOOK S SEE SOH. • • ' • • O ONE PER TOILET ROOM EF -3 L LO NI GOOK S SEE SOH. • • • • THERMOSTAT - S SEE M-502 S SEE M -502 • • • • - - S SEE SHEET M -8O2 AIR CONDITIONING DESIGN DATA 51113°L MODEL NO GFM S.P. WATTS VOLTAGE REMARKS MARK EF -U GOOK GYMINI 5-15 500 5'15^ 155 115V. Im TOILET ROOM EXHAUST EF-3 COOK LITTLE GEM -NH 100 OS° 115 IISV. 14, JAN. ROOM EXHAUST ..—.. FAN SHALL BE FURNISHED WITH SAGKDRAFT DAMPER EXHAUST FAN SCHEDULE ID. KNIKIN TOTAL MINIMM SENSIELE AMBIENT COL EAT AIRFLOW EXT. S.P. MAX VOLTS/ UNIT TOTAL HEATING CAP. MEN GAP. (BTIM) CAP. (31tH) TEMP Cr) (CFM) (IN. WC) H.P. PHASE MAWFACTURER 6 MODEL NO. REMARKS TA$ °F 4P °F wb MCA FUSE INPUT OUTPUT RTU-! - - - - - - - - - - - - - TRANE YGD360 EXISTING MU-2 - - - - - - - - - - - - - TRANE YCD3b0 EXISTING RTU3 _ _ - - - - - _ _ _ - _ - TRANE YGD300134 EXISTING R1V-4 - - - - - - - - - - - - - TRANE YGD30054 EXISTING I THIS 6 THE STATIC PRESSURE EXTERNAL TO THE UNIT. IT DOES NOT INCLUDE COIL, CASING, FILTER OR HEATER LOSSES. 2 PROVIDE UNIT NOM ENTHALPY CONTROLLED ECONOMIZER SYSTEM, POPES EXHAUST FAN RELIEF. 3. PROVIDE SHOD DETECTOR IN THE SUPPLY AIR DUCT FOR EACH UNIT. SMOKE DETECTOR SHALL SR)T DONCN THE SUPPLY FAN WHEN ACTIVATED. 4. ThE UNITS SHALL HE MSTN, ON ROOF NTH FACTORY CURB. 5. ECONOMIZER 4 SMOKE DETECTORS NOT REQUIRED ON RTU-I. EXISTING AIR CONDITIONING UNIT SCHEDULE W-. WA! m�oP mommieurrion gUCg • DESCRIPTION MAN)FACTURER MARK _ MODEL No. ® 5110E4ALI., DOUBLE DEFLECTION, AIR FOIL BLADE, SUPPLY REGISTER WITH OPPOSED BLADE DAMPER TITUS 300 RL - PERFORATED SUPPLY DIFFUSER WITH FORWAY PATTERN CONTROLLED AND OPPOSED BLADE DAMPER TITUS P55 AA PERFORATED FACE CEILING RETURN AIR GRILLE TINS PAR / SIDEWALL RETURN AIR TRANSFER GRILLE TITUS 35ORL CONCENTRIC SUPPLY/RETURN DIFFUSER GAN FAB /GF4850DJ036 -72 ADAPTOR GROUP CONGEdTRIG 51PPLY / RETURN DIFFUSER CAN FAR /GF4850DJ08 -09. ADAPTOR GROUP EM LINED SUPPLY A'RH GT ROOF STRUCTURE LINED RETURN AIR DUCT N' i ROOF • I /2' MESH. MIRE. SCREEN AT RETURN AIR DUCT OPENING. SEE FLOOR PLAN FOR DIMENSIONS NOTE: ALL DUGTNORK SHALL BE INSTALLED TIGHT TO UNDERSIDE OF ROOF STRUCTURE SECTION (RIU -45•b AND RTU -II) AIR DISTRIBUTION SCHEDULE MRF. M MODEL NO R FURNISHED EY I INSTALLED BY REMARKS TENANT b bt. T TENANT M MECH. RTU- -I THRU RTU-4 T TRANE S SEE SOH. - • • • • E EXISTING ON ROOF EF- I,EF -2 W WREN GOOK S SEE SOH. • • ' • ..—.. FAN SHALL BE FURNISHED WITH SAGKDRAFT DAMPER EXHAUST FAN SCHEDULE ID. KNIKIN TOTAL MINIMM SENSIELE AMBIENT COL EAT AIRFLOW EXT. S.P. MAX VOLTS/ UNIT TOTAL HEATING CAP. MEN GAP. (BTIM) CAP. (31tH) TEMP Cr) (CFM) (IN. WC) H.P. PHASE MAWFACTURER 6 MODEL NO. REMARKS TA$ °F 4P °F wb MCA FUSE INPUT OUTPUT RTU-! - - - - - - - - - - - - - TRANE YGD360 EXISTING MU-2 - - - - - - - - - - - - - TRANE YCD3b0 EXISTING RTU3 _ _ - - - - - _ _ _ - _ - TRANE YGD300134 EXISTING R1V-4 - - - - - - - - - - - - - TRANE YGD30054 EXISTING I THIS 6 THE STATIC PRESSURE EXTERNAL TO THE UNIT. IT DOES NOT INCLUDE COIL, CASING, FILTER OR HEATER LOSSES. 2 PROVIDE UNIT NOM ENTHALPY CONTROLLED ECONOMIZER SYSTEM, POPES EXHAUST FAN RELIEF. 3. PROVIDE SHOD DETECTOR IN THE SUPPLY AIR DUCT FOR EACH UNIT. SMOKE DETECTOR SHALL SR)T DONCN THE SUPPLY FAN WHEN ACTIVATED. 4. ThE UNITS SHALL HE MSTN, ON ROOF NTH FACTORY CURB. 5. ECONOMIZER 4 SMOKE DETECTORS NOT REQUIRED ON RTU-I. EXISTING AIR CONDITIONING UNIT SCHEDULE W-. WA! m�oP mommieurrion gUCg • DESCRIPTION MAN)FACTURER MARK _ MODEL No. ® 5110E4ALI., DOUBLE DEFLECTION, AIR FOIL BLADE, SUPPLY REGISTER WITH OPPOSED BLADE DAMPER TITUS 300 RL - PERFORATED SUPPLY DIFFUSER WITH FORWAY PATTERN CONTROLLED AND OPPOSED BLADE DAMPER TITUS P55 AA PERFORATED FACE CEILING RETURN AIR GRILLE TINS PAR / SIDEWALL RETURN AIR TRANSFER GRILLE TITUS 35ORL CONCENTRIC SUPPLY/RETURN DIFFUSER GAN FAB /GF4850DJ036 -72 ADAPTOR GROUP CONGEdTRIG 51PPLY / RETURN DIFFUSER CAN FAR /GF4850DJ08 -09. ADAPTOR GROUP EM LINED SUPPLY A'RH GT ROOF STRUCTURE LINED RETURN AIR DUCT N' i ROOF • I /2' MESH. MIRE. SCREEN AT RETURN AIR DUCT OPENING. SEE FLOOR PLAN FOR DIMENSIONS NOTE: ALL DUGTNORK SHALL BE INSTALLED TIGHT TO UNDERSIDE OF ROOF STRUCTURE SECTION (RIU -45•b AND RTU -II) AIR DISTRIBUTION SCHEDULE MRF. M MODEL NO R FURNISHED EY I INSTALLED BY REMARKS TENANT b bt. T TENANT M MECH. RTU- -I THRU RTU-4 T TRANE S SEE SOH. - • • • • E EXISTING ON ROOF EF- I,EF -2 W WREN GOOK S SEE SOH. • • ' • • O ONE PER TOILET ROOM EF -3 L LO NI GOOK S SEE SOH. • • • • THERMOSTAT - S SEE M-502 S SEE M -502 • • • • - - S SEE SHEET M -8O2 I THIS 6 THE STATIC PRESSURE EXTERNAL TO THE UNIT. IT DOES NOT INCLUDE COIL, CASING, FILTER OR HEATER LOSSES. 2 PROVIDE UNIT NOM ENTHALPY CONTROLLED ECONOMIZER SYSTEM, POPES EXHAUST FAN RELIEF. 3. PROVIDE SHOD DETECTOR IN THE SUPPLY AIR DUCT FOR EACH UNIT. SMOKE DETECTOR SHALL SR)T DONCN THE SUPPLY FAN WHEN ACTIVATED. 4. ThE UNITS SHALL HE MSTN, ON ROOF NTH FACTORY CURB. 5. ECONOMIZER 4 SMOKE DETECTORS NOT REQUIRED ON RTU-I. EXISTING AIR CONDITIONING UNIT SCHEDULE W-. WA! m�oP mommieurrion gUCg • DESCRIPTION MAN)FACTURER MARK _ MODEL No. ® 5110E4ALI., DOUBLE DEFLECTION, AIR FOIL BLADE, SUPPLY REGISTER WITH OPPOSED BLADE DAMPER TITUS 300 RL - PERFORATED SUPPLY DIFFUSER WITH FORWAY PATTERN CONTROLLED AND OPPOSED BLADE DAMPER TITUS P55 AA PERFORATED FACE CEILING RETURN AIR GRILLE TINS PAR / SIDEWALL RETURN AIR TRANSFER GRILLE TITUS 35ORL CONCENTRIC SUPPLY/RETURN DIFFUSER GAN FAB /GF4850DJ036 -72 ADAPTOR GROUP CONGEdTRIG 51PPLY / RETURN DIFFUSER CAN FAR /GF4850DJ08 -09. ADAPTOR GROUP EM LINED SUPPLY A'RH GT ROOF STRUCTURE LINED RETURN AIR DUCT N' i ROOF • I /2' MESH. MIRE. SCREEN AT RETURN AIR DUCT OPENING. SEE FLOOR PLAN FOR DIMENSIONS NOTE: ALL DUGTNORK SHALL BE INSTALLED TIGHT TO UNDERSIDE OF ROOF STRUCTURE SECTION (RIU -45•b AND RTU -II) AIR DISTRIBUTION SCHEDULE MRF. M MODEL NO R FURNISHED EY I INSTALLED BY REMARKS TENANT b bt. T TENANT M MECH. RTU- -I THRU RTU-4 T TRANE S SEE SOH. - • • • • E EXISTING ON ROOF EF- I,EF -2 W WREN GOOK S SEE SOH. • • ' • • O ONE PER TOILET ROOM EF -3 L LO NI GOOK S SEE SOH. • • • • THERMOSTAT - S SEE M-502 S SEE M -502 • • • • - - S SEE SHEET M -8O2 LINED SUPPLY A'RH GT ROOF STRUCTURE LINED RETURN AIR DUCT N' i ROOF • I /2' MESH. MIRE. SCREEN AT RETURN AIR DUCT OPENING. SEE FLOOR PLAN FOR DIMENSIONS NOTE: ALL DUGTNORK SHALL BE INSTALLED TIGHT TO UNDERSIDE OF ROOF STRUCTURE SECTION (RIU -45•b AND RTU -II) AIR DISTRIBUTION SCHEDULE COMPONENT M MRF. M MODEL NO R FURNISHED EY I INSTALLED BY REMARKS TENANT b bt. T TENANT M MECH. RTU- -I THRU RTU-4 T TRANE S SEE SOH. - • • • • E EXISTING ON ROOF EF- I,EF -2 W WREN GOOK S SEE SOH. • • ' • • O ONE PER TOILET ROOM EF -3 L LO NI GOOK S SEE SOH. • • • • THERMOSTAT - S SEE M-502 S SEE M -502 • • • • - - S SEE SHEET M -8O2 1. SGT OF WORK: BE THE MECHANICAL CONTRACTOR'S R RESPONSIBILITY TO FURNISH L Lt .E6 OTHERHUSE NOTED, IT SMALL B CONTRACTORS RESPONSIBILITY TO F EQUIPMENT RESPONSIBILITY SCHEDULE EXISTING ROOF PROJECT NO.... -. -. :.95141 DATE _ 12/7i45 DRAWN BY _ - "_.E;C STORENUdBER. 0469 SCALE. ,,AS ..NOTED FILE - 0461M701DAS 11.11111111111111.11011111. - GROSS AREA 40,045* SALES AREA 36,420* STOCK AREA 2,604*" OFFICE. AREA 269* BREAK ROOM 312* TOILET /CORRIDOR -490* REVISIONS SHEET TITLE. MECHANICAL DETAL AND 8 DULES 3/8' ROD HANSER SECURE TO EXISTING ROOF STRUCTURE WITH ANGLE IRON It 2" BOLT. BOTTOM OF HEATER • 14' -0'x AFF • CEILING MOUNTED - EXHAUST FAN UNIT HEATER. RECE Cf(Y OFTUKNED WIIA DEC 1 8 1995 PERMIT CENTER TENANT SHALL INSTALL CUSTOMER (LINENS N THINGS) PURCHASED AUTOMATION 5,5794 WITH THE EQUIPMENT AND MATERIALS PROVIDED AS FOLLOWS: WEIR-ENT AND MATERIALS PROVIDED BY MELVILLE CORPORATION FOR INSTALLATION CONTRACTOR UNITARY GONTRoLLER (87v -2) PER ROOFTOP. A/C UNIT LAITARY CONTROLLER URN -2) FOR LIGHTING CONTROL STAND ALONE CONTROL PANEL WITHOUT SCREEN AND KEYPAD (SCP3-15) 5L2K8 FLASH BALK -UP GARD AKA PGMCIA CARD (SOP -MEC) Y AIR DUCT TEMPERATURE SENSOR PER ROOFTOP UNIT RETI. R4 AIR DUCT TEMPERATURE SENSOR PER ROOFTOP UNIT CUTS RDE AR TEMPERATURE SENSOR MUST BE COWEGTED TO THE 4 UNITARY CONTROLLER (8744 -2) AIR DIFFERENTIAL PRE SWITCH PER ROOFTOP UNIT CONTROL TRANSFORMER I20V/24VAC PER UNITARY CONTROLLER (RTU -2) CONTROL TRANSFORMER I2OV /24VAG FOR SGP -815 PANEL POWER RELAY I20V/24VAC FOR LIGHTIHS CONTROL CONTACTOR FOR LIGHTING CONTROL ENG.OSUIE FOR POYER RELAY AND CONTACTOR 2 Mo./VARY CONTACT SWITGHIES HIS RMOT CS 14.4 7ELERiDiE MODEM I R40NE LIE INTERFACE FLU 1 SERIAL CGN4M4IGATIONF GABLE W/ GENDER CHANGER • ALL CGM JNICATONE AND SENSOR ARE REQUIRED B. ALL OTHER MSLELLANEOUS MATERIALS SUCH AS WIRE TIES, MOUNTING HARDWARE,'WIRE NETS, CONELTORa AND MISGELLANEDUS ELECTRICAL BOXES SHALLBE PROVIDED BT THE CONTRACTOR. G. AL. UNTARY GCNTROLLHRS (RTU-2) MCUTED ON ROOFTOP IG UNITS SHALL !3E METALLED IN THE ROOFTOP UNT CONTROL BOX. THE LOCATION SHALL ALLOW CLEAR AGCE55 70 THE UNITARY CONTROLLER (RTU -2). D. THE WP-575 PANEL SHALL BE MOULDED ADJACENT TO TE INCOMING BUILDING TELL. DIVE SYSTEM PANEL. CONTRACTOR SHALL BE RESPONSIBLE FOR PROViDNTG AND GONEGTING 3 MIRE (NOT, NEUTRAL, GROUND), 120V, AC POWER TO SGP -5 T5 AS ULDTGATED a4 TIE DRAWN55. E. ALL COM4MOATIONS LIES SWAN BE INSTALLED FROM UNIT TO UNIT AS ILLUSTRATED ON THE GRAMME WITH A CON TILIOUS CABLE. NO SPLICINS OF GOMM)WCATIONS LINES M BETIEEN ROOFTOP UNITS IS ALLOWABLE. P. ALL GOMMUNCATIDS LINES MST BE PAIRED IN A DAISY GRAIN GONFI6LRATION, FROM ONE R7U-2 TO THE NEXT. THE ORDER IN W IN1 THE GABLE 15 WR4 TO THE ROOFTOP UNITS 15 NOT FU® AS LONG AS TIE CONFIGURATON IS DAISY CHAFED (LE. CAN RIM FROMT tMT 5 TO OAT I TO LMT 5 TO UNIT 4 TO UNIT 2). 6. TE CONTRACTOR SHALL INSTALL CGHMMICATON LINES AND SENSOR WIRES IN A (EAT - MD ORDERLY MORN USING, SUFFICIENT WIRE TIES AND OTHER HARDWARE TO PREVEjr 5AG4LN5 CR EXPOSURE TO ALLOW DAMAGE. N. ALL CCMAMCATION LINES SHALL Be LABELED AT EACH RTU-2 TO INDICATE WREN' CPMMCATON L0E IS INOCMIN6 FROM PREVIOU5 RTU-2 AID WHICH. LINE 15 GOING OUT TO TIE NEXT RTU-2 TIE LAST NNMBERLD UNITARY CONTROLLER (RVU-2) 5IAL.L BE ILWSTRATED :N THE DRMOL65 FOR LIGMTMG CONTROL. ALL UNITARY CONTROLLERS (RTU -2) PALL EE SNIPPED TO TE JOBBITE NTH DESIENATED MASERS ON THEM. THE RT. ARE TO BE MOUNTED M THE CORRESPONDING NUMBERED ROOFTOP UNIT AS INDIGATESD IN THE BID - CRAPPIES. THE ONE RTU-2 NOT DESIGNATED: WITH A 1043ER BUT VAIN THE LETTERS .LC.„ WILL BE USED FOR LI6HTIN6 CONTROL As DESCRIBED ABOVE.:' J AL SENSORS AND AIR DIFFERENTIAL PRESSURE SWITCHES ARE TO BE MQRLTED ft ELII/STRATED ON THE DRAWINGS. TIC PRESSURE SWITCH 15 TO BE LOCATED DOME27TREAM PROM THE NEAREST DUCT ELBOW OR TEE AT A DISTANCE SLEFIGIENT ENOUGH TO PROPERLY ACTIVATE ME PRESSURE EATCH WPM TE ROOFTOP UNIT AHU 15.PUNNING, AM DE- ACTIVATE TIE CONTACTS WHEN THE ROOFTOP MIT AH),IS HOT RUNUN6. THE -.. . CONTRACTOR SHALL TEST THE PRESSURE SWITCH FOR PROPER OPERATION AND SHALL BE RESPOBsl&.E FOR MAKIN 5 SURE IT IS OPERATING PROPERLY. TIE TEST SH011L.D VOICATE A CONTACT CLOSURE BETYEL54 PRESSURE TERMINAL$ R t Y 141E1 THERE IS AIR FLOW IN THE DUCT AND 9HOLD BE IN AND OPEN CIRCUIT (OPEN CONTACTS/ STATE NTN NO AR PLOPL NOTE. AN ADJFTNSNT SCREW IS PRESENT ON EACH AIR DIFFERENTIA. PRESSURE SWITCH N41O44 ADJ5T5 THE PRESSURE LEVEL. REWIRED TO ACTIVATE AND DE- ACTIVATE TIE SNITCH. .: K ALL SENSOR NRE SHALL BE TAGGED ON BOTH ENDS (AT THE SENSOR AND THE UNITARY). 11E RETURN AIR DUCT TEMPERATURE SENSOR SHALL BE TAGGED AS 517 TE RIPPLY AIR DUCT TEMPERATURE SENSOR SHALL BE TAGGED AS 52; 11E AIR DIFFERENTIAL PRESSURE 9NTCN SHALL BE TAGGED A$ 53; AND THE OUTSIDE AIR TEMPERATURE SENSOR CONNECTED TO RR! AI SHALL BE TAGGED OA. L NARK TE ROOFTOP LMT N1M1BHt CORRESPONDING TO TIE DRAWING AND TE RTU-2 WEER ON 71E EXTERIOR OF THE ROOFTOP UNIT IN A NEAT LEGIBLE MANNER USING A E9.ACCK FORNIAAMITMARKER. M. 11E CpNTRACTOR SHALL IDENTIFY TIE LAST LINE ON THE TELEPHONE SYSTEM BY 55SCTNG TIE LINE AND CALLITK THE APPROPRIATE TELEPHONE NUMBER TO SEE IF TE LINE RN465 BUS, ONCE THE LAST LINE HAS BEEN DETERMINED, THE CONTRACTOR WILL THEN CONTACT HIGROTE. AUTOMATON SYSTEMS (HAS) PATH THE CORRECT TELEPHONE Num5EFR FOR SETUP PUPOSES. T. CONTRACTOR WILL THEN INSTALL_ THE MODEM AND PHONE LPE INTERFACE (PLO AS ILLUSTRATED ON THE DRARINIGS. AFTER INSTALLATION $4555 MEN PERFORMED, THE CONTRACTOR WILL CONTACT HAS AGAIN TO CHECK THE MODE4 AND PLI 70 MAKE SURE THEY ARE FUNCTIONING PROPERLY:. K TIE SNITCH 5ET1IN&S FOR TIE US ROBOTICS MODEM NEED TO BE SET E4 THE FOLLOPING MTANER IF TEY ARE NOT SET ACCORDM&LY, WE WLL BE UNABLE TO COMIMUNOATE NTH THE SYSTEM. .. MDOW4 2-UP 8-UP 4-DOWN SUP 4441• 7420.4 /3 DOLN THE 686t, REQIREENT5, OTHER GONDITIONS, SECTIONS AND DIVISIONS, AS AFR07PRATE, APPLY TO WORK SPEGFlED IN THIS DIVISION. ALSO; ALL MEGF.AECAL-./ONS' SHALL EE PROVIDED M- STRICT KGORDANCE WITH STATE AND LOCAL CODES EPA STANDARD ROA AND WITH TIE STANDARDS AD DETAILS OF TENANTS GOFL•F.L'TION •AR.TIENT. 2 THE MEG/ NC, DRNSSATS ARE DIASRASMATIG, MENDED TO SHOW GENERAL ARRA.6'ENT A V SIZES OF SYSTEM COMPOI8R5, AND SHALL NOT BE SCALED. RATTER Tie ARCHITECTURAL AND STRUCTURAL DRAWINGS, AND EXIST. CCKMIORS SSHAJ. 6OVEF N SPACE CONSTRAINTS, KTUAL CONNECTION ARRANGEMENTS, MENSIONS AND FIMS, . CONTRACTOR SHALL VISIT Tie PRO,ECT SITE, TNOROJ6H.Y RESTI6ATE AND BE FAMILIAR WITH ALL EXJSTWG CONDITIONS MICH WILL AFFECT THEIR RORK. TIE EQUIPMENT LOCATIMS SHOWN ARE APPROXIMATE AND M15T BE APPROVED BY EON LE55' N THIY65 AND THE LANDLORD. ALL OFFSETS AND PITTIN.5 WHICH WILL BE 5eCE55ARY TO ACCOMPLISH THE FINISHED PETALLATO5 SHALL EE FRONDED AT NO ADDITIONAL 5057 OR INCREASE IN THE CONT.,. AU_ EGUI,E4T AND MATEQIALS SHALL BE NEW UNFSF NOTED OR S OT1H315E PROTECT ALL EQUIP534T AND MATERIALS FROM DAMAGE. PROVISIONS MALL. EE MADE TO PREENT NOISE AND VIBRATION 3. LANDLORD AND/OR. CONTRACTOR S4ALL SECURE AND PAY ALL FEES An0c,IATED WITH AU_ PERMITS AND H 540555 REWIRED FOR E600505 OF TIE GONTRKT. ARRANGE FOR ALL INSPEC5055 REQUIRED BE LOCAL, CITY, COUNTY, STATE, AND OTIE R AUHi0R1TTF5 HAVE. LRISDIGTION 4. - THREE WEDIF.4110!5 AND TIE ACCOMPANYING DRAWINGS COVER TIE PROVISION OF ALL LABOR 52RFMS5T, APPLJ55555 AND MATERIALS AND PERFDRMIN6 ALL OPERATIONS IN CONVECTION WTI THE GOSTRUCTON OF THE AIR CONDITONIN6, VHatATio / AND 5FA1158 575785 AS 5PEEFIED HEREIN AID AS 540Y4. 5. TE ILEUM AND STATED IN'i84T OF TIE MARINES AND SPECIFICATIONS 15 TO E5TA81J34 MEW ACCEPTABLE STANDARDS FOR MATERIALS, EQUIPMENT AND YD 065 54 AND TO FROV.E OPERABLE 5ECMANICXL 6151EM5 COMPLETE M EVERY ALL PORK PROVIDED UDER THIS WC11ON SHALL BE 04.8SCT TO A MINIMUM ONE TEAR 5 RRANLY. TE WARRATY.SHALL 05UDE PRON4 T RE3�55R OR R131LAG854T OF ENVI 5OR 5YSTE M FAILURES AND SHALL INCLUDE ALL PARTS MD LABOR IN ADDITION ALL RFCFROGAT1NS AIR 4055555055555 45555 E550R5 SHALL GARRY AN AMMON . rout YEAR PAR75pEY MIARRATY. enTsioFS WARRANTEE SHALL EE PROMO ®ON ALL Ori$tEG 5565ff ISO SPECIFIED I ENAME, 1_ COORDINATE VOLTAGE AND 55555E OF EACH PIECE OF EO)IPM ENT PATH ELECTRICAL CONTRACTOR MFG.. OPERATNG. ALL MIR MRS AND FINAL CONEGTOI5 TO WILIRE47 SHALL BE PROVIDED wpm TE ELECTRICAL DIVISION: CONTROL COMPOeIT5 AID AL +4T550555 AD CONTROL MRM6 SHALL BE PROVIDED BY THE 555459 65 CONTRACTOR AS REDIIRED TO ACHIEVE PROPER CONTROL SEGE.55.. ALL CONTROL NM. 0VER 30. VOLTS SHALL BE METALLED BY A LICENSED EICIRIGAN Y ORCBLS FOR TMhE 4554455. CONTRACTOR . 8. ALL NFINWPC 50 EQUIPMENT, THAT REWIRES I18RICATON SHALL BE UJBRCAIED IN STRGT ACCORDANCE FM TE MUWJFACTURHRS REOCTREDATON S. ALL CONTROL EQIPM54T SHALL EE ADJETED -TO THE SETEN. R"OUI.D FOR 1IE FERFORMANCE 5RFLFIED. FANS S - EIS ADJ67ED TO TIE. EPIC INDICATED BY TE IAMIFAGT RER TO NMI THE INSTALLED FINAL SYSTEM 5856649E AT THE ARMORS INDICATED. MISCBLIIFCVS ADISTMENTS TO ELECTRICAL SPECIFICATIONS TO ALLOW PROPER BAS INSTALLATION t. A DEDICATED 120V AG CIRCUIT SHALL BE PROVIDED. FOR ROOFTOP UNIT CONTROL PANE IN A SLID JUNCTION BOX FOR CONNECTION TO 120VAG TRANSFORMERS. THE 420VAO GROUT IS TO BE PETD BY A 20 AMP 120 VAC CIRCUIT BREAKER - CLEARLY MJ.RIOED FOR BAS CONTROL IT SMALL NOT BE J)NGTIONED OFF OF A. CIRCUIT USED FOR OTER PLRPOS.zS. THE 120VAC BAS 'J" IEOXES MAY AU. BE SUPPLIED FROM THE SAME DEDICATED 120VAC CIRCUIT BREAKER, 2 A DEDICATED SIRE POT, NEUTRAL, GROUND), 120V CIRCUIT SHALL BE PROVIDED WITH A JJNOTION BOX AT THE SCP-575 CONTROLLER LOCATION IT SHALL HAVE A SEPARATE CIRCUIT BREMQ32 AND ENE LABELED AS MASTER BAS CONTROLLER POPPR. 3. A 420 VOLT LAY VOLTAGE TRANSFORMER POWER CIRCUIT SHALL BE PROVIDED AT THE GGHT1. GDNIROL RELAY PANEL. BUILDING AUTOMATION SPECIFICATIONS TEEING AND BALAMG4590F PE HVAC SYSTEM SHALL E 5055 IN ACCORDANCE . MTH THE 575550055' OF AABG AND 044400 88 PERFORMED BY AN 050551550840 CERTIFIED TEST AD BALANCE 9.I ES2 85654544+0055 FRONDED M STRICT ACCORDANCE MTH 11E FIRST EDITION - ,H85 CF TIE SM.K.NA wAC DUCT 40581 UCTON STAND ARDS 15TAL AND FLEXIBLE, UEFA NOWA AND LL IV.L CUGTMLOIRK SHALL BE CONSTRWTED FOR STANDARD I. PIG STATIC PRESSURE GLASS AT 2500 FR4 55TH GLA5GG 5FAL5. DUCTWORK SHALL BE FABR+CATED FROM LOCK - FORM. GRADE 640 -AST4 A 5.3 NOT DIP GA YARDED 5TEEL.EET5. SHEENWAL SHALL EE 6ALVANIED ON EACH SIDE WITH NOT LEE THAN 135 OIRKES OF ZINC FE R SCEJARE FOOT. DUCTWORK SHALL EE RMED AND FINNED PER TENANTS PANT SEC. ALL DUCTWORK SHALL BE RECTANSLLAR TYPE AND SMALL 85 THE PRODUCT OF UNITED MG61LL GOT80RATION, R.V. MONEY. OR AN 55550050 EQUAL. ALL DIETWORK MEN THIRTY FAT OF AN ENTRANCE SHALL BE LNTED MCGILL ALOVTI -K2"7. 12. AIL PQRnoNS OF DUCTWORK VISIBLE THROWN SUPPLY AND nruRN AIR GRILLE SHALL BE PANTED FLAT BLACK - - 53. DUCT LAM 5HAL EE 05E MGk THCX I I/2 LB. DENSTY FIBROUS GLASS PATH ONE FKE COATED mil/ A LSLACK FIRE RETARDANT COMPOUND. D. TE PERMANENT COHP051TE FIRE AND 942l.'E HAZARD RATE. OF THE OM SHALL EE STENCILED ON THE LEER FACE AND MALL M • P-AXE4,M FLAME S•READ 25 E- RAMS 4 SMOKE DEVELOPED 50 DUCT SIZE IDIGATED ON THE DRAWN. IS T. CLEAR INSIDE DIMENSION. MOT IN3AP.TO3 SHALL 6E t UY THICK WEEMS,. PATH AN ALUMNIM FOIL JACKET, RHIFORCED WTI FEE RNA55 SCRIM. TAPE SHALL BE ALUMINUM FOIL AND SHALL I5 SM5GNA L6TED AND LABELED. TIE COMPOTE 1FPA ROA, 55TM5E 4, AND UL RATE. OF TE MSTAi • ASP ELSULAT7CN S NOT EXCEED 25/50. 15. LINED DUCT SHALL SE PROVIDED FOR THE FIRST IO FBROR THROUGH THE FIRST 8- 80555) OR AS 05405'405 INDICATED ON TE DRAWNGS, WHOEVER 15 6REA155 12MSTREAH OF THE AIR COMMON,. MT. DUCT LINER SHALL ALSO BE PROVIDED THRO:6HOJT ALL RETURN AR DWTYDRY. AND PLENUMS. ALL CONCEALED DUCTWORK WHICH 15 NOT LINED SHALL BE iNsLATED. ALL JOINTS SHALL BE SEALED WITH 2. WIDE SMK.NA TAPE. ANY CUTS OR -EARS SHALL BE SEALED WITH SMIAGNA TAPE. SPECIFICATIONS Ib. PROVIDE U.L. LISTED HEAVY ELMS FIBER FABRIC DUCT CONEGTOR AT FAN 505055CTORS, THE CONECT060 SHALL BE AT LEAST 4. LONG AND SHALL HAVE A NA=TAL STRAP AT EACH END. ALLOW I. OF SLACK FOR VIBRATOR ISOLATION ALL AIR DISTRIBUTION DEVICES SHALL BE SELECTED IN ACCORDANCE PAIN THE FOLLOWING MNIMIM CRITERIA: METHOD OF MOUNTING SHALL BE COMPATIBLE WITH THE CEILING, WALL OR DUCT SURFACE WO; IT MOUNTS ON CR IN; I.E. LAY -IN SURFACE MOUNTING, PLASTER FRAME, DUCT COLLAR, ETC. TIE ARCHITECTURAL DRAWINGS SHALL BE REFERENCED TO DETERMINE THE MOUNTING METHOD FOR EACH DEVICE. ALL FLANGES ON % AGE MOUNTED DEVICES SHALL BE PROVIDED WITH A GASKET. c. FINISH OF ALL GEL. MOUNTED DEVICES SHALL BE SELECTED TO MAT. THE COLOR OF THE ADJACENT GEL.. d. ACG55TABLE MANIFAGTuRER5 ARE ANEMOSTAT, GARNES, METAL -AIRS AND TITUS. e. . CEILING DIFFUSER. (CD) SHALL BE PERFORATED FAGS 01FFUSER5 EWIPPED WITH RACY ADCETABLE PATTERN CONTROLS, CAPABLE OF PROVIDING ONE - WAY, TWO- WAY, TWQ -W.AY CORNER, THREE -WAY, AND FOUR -WAY AIR PATTERNS; CARIES SPAR. DIFFUSER PERFORMANCE DATA SHALL SE IN ALGORDALE WITH ADG EQUIPMENT TEST CODE 16284. THE PERFORATED FACE SHALL BE HINGED FOR EASY ACCESS TO PATTERN CONTROLS AND DUCT AGGESSORIES. THE MAXIMUM MC LEVEL AT DESIGN AIRFLOW SHALL NOT EXCEED 35 WEN MEASURED IN A DIRECT FIELD 5' -01 FROM 114E FAGS OF THE DEVICE. P. RETURN AR GRILLES (RA6) SHALL BE HOLLOW GORE 24. X 24. PERFORATED PALE: NECK SIZE SHALL BE AS INDICATED ON THE DRAWING. ALL OTHER CHARAGIER5TTG5 SHALL BE EQUAL TO THE CEILING DIEM ER. g.. SUPPLY REGISTERED (RE6) SHALL 8E 5URFALE MOUNTED, 5TE5, ADJBTABLE DOL9LE- DEFLECTION TYPE OOM.PLETE WITH OPPOSED ELIDE DAMPER5 FOR BALANCING FURP05E5. THE OU5ERMO511 SET OF DEFLECTION ELADE5 SHALL BE PARALLEL TO THE LONG DIMENSON OF THE 5R THE REGISTERS SR, BE TESTED IN ACCORDANCE WITH ADC STANDARDS AND SHALL BE SB.EGTED TO PROVIDE DESIGN AIRFLOW AT A MAXIMM NC OF 55. 17. CONDENSATE DRAMS SHALL BE COPPER OR GUARANTEED PIPE NOT LEE THAN 11 NOMINAL. PIPE SIZE. DRAIN FIFES SHALL BE INSTALLED PER MANIFKTURER5 .. REGOt-4ENDATONS'.AND LOCAL CODES.. PROVIDE DEEP SEAL. P -TRAP AT THE I1N1T AND ROUTE TO APPROVED DRAIN RECEPTOR OR NEAREST ROOF DRAIN. 18. REFRIGERANT PIPING IF REQUIRED SHALL BE TYPE °L' HARD DRAWN COPPER TLBEB WITH SILVER BRAZED JOINTS AND SNAU- BE SIZED PER MMUFKNRERS RECOMMENDATIONS. REFR.BLA15 PIPM6 SHALL HAVE I/2. THICK ARHAFLEX 25/50 INCiLATON. IN.LATION INSTALLED OUTDOORS SHALL HAVE. ARMACOAT PROTECTIVE COATIS. I9. ENERGY' MAN./ ENT SYSTEM PROVIDED BY TENANT. 20. ALL REGIRGLAT5. AR SSYSTEM5 (PACKAGED ROOFTOP ours, ETC) HAVING A DESIGN AIRFLOW CAPACITY OF 2000 GFM OR GREATER SHALL HAVE SMOKE DETECTORS METALLED TO DETECT THE PRESENCE OF SMOKE AND AUTOMATICALLY STOP THE FANS).14 ACCORDANCE RUTH APPLIGABLE.CODES. 51.10KE DETECTORS SHALL BE FRONDED L DER 7415. DIVISION 15 M AGGORDANGE WITH NPPA 12E. ALL SMOKE DETECTORS SHALL BE PROVIDED IN ACCORDANCE WITH TIE REQUIRE/4MS OF THE NIFFA 5TANDARD5 (NEPA 11, 12A, 728,126 AND 120); AS APPLICABLE. NO SYSTEM SHALL RESTART UNTIL THE LOMROLS ARE MAWALLY RESET. 21. TENANT TO INSTALL ENERGY MANAGEMENT SYSTEM • WHiii1 WILL EE MAN FACTORED BY TRIANGLE MICRO SYSTEMS AND DISTRIBUTED BY MICRO TECH. AUTOMATION SYSTEMS INC. TEL: 513248 -GIRO JILLJAN HAUEPR PROJECT Ham. "=45141. DATE. I2/1/45: DRAWN BY. 56 STORE NUMBER. 0464 SCALE ''AS'NOTED FILE. L7M801:DW6 GROSS AREA 40 ,045* SALES AREA 36,4206 STOCK AREA' 2,6048 OFFICE AREA "' 2648` BREAK ROOM '. 5128 TOILET /CORRIDOR . 4408 REVISION& SHEET TITLE.: SPECIFICATIONS 1RPt 1.tvOS MR.0 <o.+R,.. SPRY M P... MINOR SPIRT ARlR01111 PM mitt tt '�a is'iTR3• • �f�c °rou°o e7L LOLAIIIM A.NwCR.wls 1 BRIM, MIMI. — �on.rRL <un�.s 11/Me06. RIOT M ROOPTCI 1T 31PrAM NAT / wr ed.e.eAT/,snaRCaaL Nur 1a 17°6 NW CONCCT TMS 1 FACILITEC BAS TYPICAL RTU 1000 —C INSTALLATION / WIRING DETAILS fig PAIR !ram, PLg✓1M CABLE PROVIDES wars - S EEA ADDITIONAL LILAC SWEETS NUTS - EC ADDITIONAL SWEETS BE LONELTIL BETA163. TYPICAL BE(Y@]1 ALL NUTS. RNt TO LOTTRO- OUTDOOR SON LIGIRYK AHD FUTURE 2000R 1.16HTIN5 CONNFOT.ONS - EXIST". (BREAKER MONT PAM, CRT@ECLOCK AND ADDS AS TTE LAST UNIT IN BE SYSTEM 1E, 8 Roam, NUTS - TE<5 APPRIMS T tjt 1 1{ L EPCJ�3 CONTPALER TO EE LOCATED NEXT TO PHWE PMF2. PAti9. �RiV -G ROOFTO WIT .1 °I' vec.n RTUL LOMR TURN IN LOMRq SECTIOi Or VHIT. RETURN AIR SECTION MAYBE US® AS A MOMTf.'S LOLATON. LEGATE NUT3 TO AVOID LINE VELTA6E DEVICES ARP WIRING.. ROOFTOP NUT M2 ROOFTOP UNIT RS ROOFTOP UNIT a4 ROOFTOP UNIT 5 IRS N? .76°P uuMu EMI uu R ADDRESS S.. IN BEGVEKTIAL ORDER - 4.11 THE ADDRESS EE M PHTSILAL ORDER TMS / FACLITEC BUILDING AUTOMATION SYSTEM RISER DIAGRAM RATVg TO ADDITIONAL ROOPTOP UNITS SAFE rfe - ADDRESS THE SAMIE A9 T1E UN T NUMBER ADDRESS TABLE RTU-C ADDRESS SMUT. SETTINGS ON ON 2 3 ON ON ON ON 4 ON 1 ON ON ON OFF OFF ON ON ON ON OFF TOFF ON ON OFF ON ON OFF ox ON ON OFF OFF ON ON ON OFF OFF ON OFF ON ON 10 ON ON ON OFF ON 12 ON OFF ON OFF IoF ON OFF OFF ON ROOF TOP UNIT RETURN DUCT SUPPLY DUCT PRTMOUNT FFERENTIAL AIR DUCTWORK DIWITH I LY. TUBOIN6 TTOM K1.1 CONNECTION <P. , AIR � IRI"DUG LOCA,ON TOO INSURE SOODAIR FLOW TLO RGTOFRGN,A r TMS / 67 �RN REGT,r v ReulEACmeRx ne L d None+ ..TAR,n cc:Avowal. 0 «M. ,1111 6� teJ{LSig6Fl O [MOR/Y % o g (J P1O•' JIL I cc.91 arA1e gAg MTM. i'ak° i'ee R�PTaP N,.� H�T, FALILITEC Mme« T,.>.. ,run.. T ol� III TO nRT RroFTOP MT iH LOOP FACLITEC BAS CONTROLLER AND LIGHTING RTU -1000 WIRING DETAILS w RifffINAMP"" 15 RL50TIL6 Noce+ I .nu sEnlues . tkJMN 5. L.r P DOW M e. Ov PLI TELEPHONE INI£RCIU EC Pongt PROJECT. NO: 45141 DATE.. (2/7/95 DRAWN BY. , ::. EG= STORE NUMBER, 0464 SCALE, AS NOTED LTM O2iDWG -. GROSS AREA `40,0454' SALES AREA 36,4209 STOCK AREA - 2,6049, OFFICE AREA 264* BREAK ROOM 3129E ' TOLET /CORRIDOR 440* REVISIONS, - SHEET TITLE, BUILD D AGRRAJ48 MOUNT SRACE SENSOR IN g OF RETURN AIR DUCT lWAG OTIERWISE NOTED ON WAG TD OWUI COMROLLER IN UNIT (1 PAIR R TO RN UNIVERSAL INPUT 3 TMS / FACILITEC BAS TYPICAL RTU 1000 —C ADDRESS TABLE & SENSOR INSTALLATION DETAILS EOM R46^i Q V EAOC US ePO TG MO PTO 5P49T3 RECENED CfIV OF TUKWILA DEC 1 8 1995 PERMIT CENTER' -,: TMS _1 FACILITEC ' BAS TELEPHONE ACCESS .MODEM CONNECTION EDTAIL S'