Loading...
HomeMy WebLinkAboutPermit D06-351 - Wig Properties - South Building - Slab and FootingsWIG PROPERTIES S BUILDING 17200 SOUTHCENTER PY D06 -351 City bf Tukwila Parcel No.: 2623049081 Address: 17200 SOUTHCENTER PY TUKW Suite No: Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: ci.tukwila.wa.us Tenant: Name: SOUTHCENTER SQUARE - BLDG S Address: 17200 SOUTHCENTER PY, TUKWILA WA Owner: Name: WIG PROPERTIES LLC-SS Address' 4811 134 PL SE, BELLEVUE WA, 98006 Phone: Contact Person: Name: LESITYA WIG Address: 4811 134 PL SE, BELLEVUE WA, 98006 Phone: 425 9574774 Contractor: Name: WIG PROPERTIES LLC-SS Address: 4811 134TH PL SE, BELLEVUE WA 98006 Phone: (425)641 -2044 Contractor License No: WIGPRPL945N3 Value of Construction: $90,000.00 Type of Fire Protection: Type of Construction: DEVELOPMENT PERMIT "continued on next page" Expiration Date: Steven M. Mullet, Mayor Steve Lancaster, Director Permit Number: D06 -351 Issue Date: 10/20/2006 Permit Expires On: 04/18/2007 DESCRIPTION OF WORK: POUR SOUTH BUILDING SLAB (APPROX 50,000 SF) ON GRADE ONLY AND DO INTERIOR PAD FOOTINGS. Fees Collected: $1,894.05 International Building Code Edition: 2003 Occupancy per IBC: 0019 doc: IBC - PERMIT 006 -351 Printed: 10 -20 -2006 Public Works Activities: Channelization / Striping: N Curb Cut / Access / Sidewalk / CSS: N Fire Loop Hydrant: Flood Control Zone: Hauling: Land Altering: Landscape Irrigation: Moving Oversize Load: City bi Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: ci.tukwila.wa.us N N Permit Number D06 -351 Issue Date: 10/20/2006 Permit Expires On: 04/18/2007 Number: 0 Size (Inches): 0 Start Time: End Time: Volumes: Cut 0 c.y. Fill 0 c.y. Start Time: End Time: Sanitary Side Sewer: Sewer Main Extension: Private: Public: Storm Drainage' Street Use: Profit: N Non - Profit: N Water Main Extension: Private: Public: Water Meter: N Permit Center Authorized Signature' doc: IBC- PERMIT Steven M. Mullet, Mayor Steve Lancaster, Director Date: �III�(lAp I hereby certify that I have read and x I ed his permit and know the same to be true and correct. All provisions of law and ordinances goveming this work will b mp with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction performance of work. I am authorized to sign and obtain this development permit. Signature / � Date: /e /.2o t; o / Print Name: AZ itia4 This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. D06 -351 Printed: 10 -20 -2006 City W Tukwila Parcel No.: 2623049081 Address' 17200 SOUTHCENTER PY TUKW Suite No: Tenant: SOUTHCENTER SQUARE - BLDG S 1: ' "BUILDING DEPARTMENT CONDITIONS*** doc: Conditions Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: ci.tukwila.wa.us PERMIT CONDITIONS "continued on next page** 4: The special inspections and verifications for concrete construction shall be required. Steven M. Mullet, Mayor Steve Lancaster, Director Permit Number D06 -351 Status: ISSUED Applied Date: 09/25/2006 Issue Date: 10/20/2006 2: No changes shall be made to the approved plans unless approved by the design professional in responsible charge and the Building Official. 3: All permits, inspection records, and approved plans shall be at the job site and available to the inspectors prior to start of any construction. These documents shall be maintained and made available until final inspection approval is granted. 5: When special inspection is required, either the owner or the registered design professional in responsible charge, shall employ a special inspection agency and notify the Building Official of the appointment prior to the first building inspection. The special Inspector shall fumish inspection reports to the Building Official in a timely manner. 6: A final report documenting required special inspections and correction of any discrepancies noted in the inspections shall be submitted to the Building Official. The final inspection report shall be prepared by the approved special inspection agency and shall be submitted to the Building Official prior to and as a condition of final inspection approval. 7: All construction shall be done in conformance with the approved plans and the requirements of the International Building Code or International Residential Code, International Mechanical Code, Washington State Energy Code. 8: Notify the City of Tukwila Building Division prior to placing any concrete. This procedure is in addition to any requirements for special inspection. 9: All wood to remain in placed concrete shall be treated wood. 10: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. D06 -351 Printed: 10-20 -2006 City &' Tukwila I hereby certify that I have read these conditions and will comply with them as outlined. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provision of any other work or local laws regulating construction or the performance of work. Signat re: Print Name'7: /& J& doc: Conditions Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: cttukwila.wa.us Steven M. Mullet, Mayor Steve Lancaster, Director Date: /b /ao D06 -351 Printed: 10-20 -2006 Tenant Name: Property Owners Name: Mailing Address: Company Name: Mailing Address: Contact Person: E-Mail Address: Company Name: CITY OF TUKWILA * Public Works Department Permit Center 6300 Southcenter Blvd., Suite 100 'Tukwila, WA 98188 htto://www.ci.tukwila.wa.us Company Name: CS KW PUBLIC WORKS PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. "Please Print** King Co Assessor's Tax No.: 2-1, - 3)4 1011 Site Address: 200 S eat Va.) a t t Suite Number. Floor: New Tenant: ❑ .... Yes 0 LA t ft of ickec. LLC -SS �{f11 nti \-`A f ltcvt cy Name: tl \\(4o L )e cAert o f St W i Mailing Address: (J E -Mail Address: r keAC CC S Pxf . Cn re Col t✓l c t c.‘o01/4f t° c s cJ. ov e V e \.to,k k ' Q:UpplicmlauWamrApplicatiaa On LineV•2006 • Public Wale Pamit Application/Ix Revised: 42006 bb LLC - SS It .'A State Zip Day Telephone: $ / 5 S 14 - 26 a qis/ In—q Al City SMe Tip Fax Number. �i 2 7 �6 5 - 8 6`t City Day Telephone: Fax Number. Contractor Registration Number. Expiration Date: State Zip Mailing Address: GAM Person: h ` t 3 r d u.r A ik of Sin n i O V t nt. et 3 Day Telephone: 425/ & 2 - 2\ tO E -Mail Address: 'S kil a to r r s c- M ) H.30 Mk(' \k. r,� M Fax Number: State hip Mailing Address: 1 1, City Contact Person: Ron Crno1C'Sr c'r Sql� te C Pr Day Telephone: 2_06 / 323 - 9 E -Mail Address: 'i c\ Q0 1 ;Act n C . Cr) on Fax Number. State Zip Page 1 of 3 Valuation of Project (contractor's bid price): S QO , Ono Scope of Work (please provide detailed information): e t, p,r Will there be new rack storage? ❑ ..Yes ❑.. No (If yes, a separate permit and plan submittal will be required) PLANNING DIVISION: Single family building footprint (area of are foundation of as structures, plus any decks over to Indus and overhangs greater than IS inches *For an Accessory dwelling, provide the following: Lot Area (sq ft): Floor area of principal dwelling: Floor area for accessory dwelling: 'Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard: Compact: Handicap: Will there be a change in use? ❑ ....Yes ❑ ..No If "yes ", explain: FIRE PROTECTION/HAZARDOUS MATERIALS: D.. Sprinklers ..Automatic Fire Alarm ❑..None ❑. Other (specify) Will there be storage or use of flammable, combustible or hazardous materials in the building? 0.. Yes ❑..No If "yes", attach list of materials and storage locations on a separate 8 -1f2 x 11 paper Indicating quantities and Material Safety Data Sheets. SEPTIC SYSTEM: On -site Septic System — For on -site septic system, provide 2 copies of a current septic design approved by King County Health Department. Q Uppautia sWornu-Appantime On t.ineU30a6 -Permit Applicaren.t .c Revved: 4-2006 s6 Existing Building Valuation: S Page 2 of 6 tk is imli � T i4n no Y � �tlY nt�� t Y �t{`5'!+'3)�idb s� � 1odeI x T w �1110(}GF 4saJ ";IPM * y� �dt 6��„.?t.0 �a xi ti y.,;:. �§ a �'f+u�i'e�4#�2 2 :., 444 y K+,ML .Y/ P i k .J S�yy -:Utrar�`s% D`k4* Valuation of Project (contractor's bid price): S QO , Ono Scope of Work (please provide detailed information): e t, p,r Will there be new rack storage? ❑ ..Yes ❑.. No (If yes, a separate permit and plan submittal will be required) PLANNING DIVISION: Single family building footprint (area of are foundation of as structures, plus any decks over to Indus and overhangs greater than IS inches *For an Accessory dwelling, provide the following: Lot Area (sq ft): Floor area of principal dwelling: Floor area for accessory dwelling: 'Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard: Compact: Handicap: Will there be a change in use? ❑ ....Yes ❑ ..No If "yes ", explain: FIRE PROTECTION/HAZARDOUS MATERIALS: D.. Sprinklers ..Automatic Fire Alarm ❑..None ❑. Other (specify) Will there be storage or use of flammable, combustible or hazardous materials in the building? 0.. Yes ❑..No If "yes", attach list of materials and storage locations on a separate 8 -1f2 x 11 paper Indicating quantities and Material Safety Data Sheets. SEPTIC SYSTEM: On -site Septic System — For on -site septic system, provide 2 copies of a current septic design approved by King County Health Department. Q Uppautia sWornu-Appantime On t.ineU30a6 -Permit Applicaren.t .c Revved: 4-2006 s6 Existing Building Valuation: S Page 2 of 6 Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. )fuilding and Mechanical Permit The Building Official may grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be requested in writing and justifiable cause demonstrated Section 103.32 Intonational Building Code (current edition). Plumbinn Permit The Building Official may grant one extension of time for an additional period not exceeding 180 days. The extension shall be requested in writing and justifiable cause demonstrated. Section 103.4.3 Uniform Plumbing code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNE O3AUTHORIZED AGENT: Signature: Print Name: L e3 t 9 Q 1.1 Mailing Address: S a q9 0 - ct o.. cierrt Date Application Accepted: 61. frzet n QMpplk:uimdF«vu- Applieniau On LineU -1006 - Peril Applieuion.due Revised: 4-2006 bh Date Application Expires: 513 j2 J Date: ) !Lb/ .L. Day Telephone: ? 2-Si G S 4 1 11 1 V City sure Tap Staff Initials: Page 6 of 6 • (tiFe 3 pq ! t2ty - : Figute;Ti l 5 u! a 9p i' Qt) ='. ' ' _ , eo- Bathtub or combination bath/shower Drinking fountain or water cooler (per head) Food-waste grinder, commercial Wash fountain Receptor, indirect waste Gas piping outlets Bidet Clothes washer, domestic Floor drain Sinks Dental unit. cuspidor Shower, single head trap Urinals Dishwasher, domestic, with independent drain Lavatory Water Closet Building sewer or trailer park sewer " Rain water -system — per drain (inside building) Water heater and/or vent Industrial waste pretreatment interceptor, including its trap and vent, except for kitchen type grease interceptors Repair or alteration of water piping and/or water treating equipment Repay or alteration of drainage or vent piping Medical gas piping system serving one to five inlets/outlets for specific gas Additional medical gas inlets/outlets — six or more - PLUMBING AND GAS PIPING CONCrOR INFORMATION Company Name: Mailing Address: city state Contact Person: Day Telephone: E-Mail Address: Fax Number: Expiration Date: Contractor Registration Number. Valuation of Project (contractor's bid price): S Scope of Work (please provide detailed information): Indicate type of plumbing fixtures and/or gas piping outlets being installed and the quantity below: Q1Applic i Fams- Applicni0a On Line U -2006-Permit Appliatioe.doe Raised: 4 -2006 bb ZiP Page 5 of 6 ACCOUNT ITEM LIST: Description Current Pmts City of Tukwila 6300 Southcenter BL, Suite 100 / Tukwila, WA 98188 / (206) 431 -3670 Parcel No.: 2623049081 Permit Number: D06 -351 Address' 17200 SOUTHCENTER PY TUKW Status: APPROVED Suite No: Applied Date: 09/25/2006 Applicant: SOUTHCENTER SQUARE - BLDG S Issue Date: Receipt No.: R06 -01683 Payment Amount: 1,149.68 Initials: JEM Payment Date: 10/20/2006 09:26 AM User ID: 1165 Balance: $0.00 Payee: WIG PROPERTIES, LLC - SS TRANSACTION LIST: Type Method Description Amount Payment Check 1453 1,149.68 BUILDING - NONRES STATE BUILDING SURCHARGE RECEIPT Account Code 000/322.100 1,145.18 000/386.904 4.50 Total: 1,149.68 0943 10/20 9710 TOTAL 1149.68 doc: Receipt Printed: 10 -20 -2006 City of Tukwila 6300 Southcenter BL, Suite 100 / Tukwila, WA 98188 / (206) 431 -3670 Parcel No.: 2623049081 Permit Number: 006 -351 Address' 17200 SOUTHCENTER PY TUKW Status: PENDING Suite No: Applied Date: 09/25/2006 Applicant: WIG PROPERTIES - SOUTH BUILDING SLAB Issue Date: Receipt No.: R06 -01502 Payment Amount: 744.37 Initials: JEM Payment Date: 09/25/2006 04:27 PM User ID: 1165 Balance: $1,149.68 Payee: WIG PROPERTIES, LLC -SS TRANSACTION LIST: Type Method Description Amount RECEIPT Payment Check 1405 744.37 ACCOUNT ITEM LIST: Description Current Pmts PLAN CHECK - NONRES Account Code 000/345.830 744.37 Total: 744.37 0131 09/26 9716 TOTAL 744.37 doc: Receipt Printed: 09 -25 -2006 Project: J/� c, . ( re.Lr& /,y /� -C/u/� Type of Inspe lly o.�,, "� 1� r i Address: � , r �� Date Called: Spe u : ial Ins Date Wanted 9— J/— 0� P.m. equester: Phone No: -• 3 INSPECTION NO. INSPECTION RECORD Retain a copy with permit PERMIT NO. r CITY OF TUKWILA BUILDING DIVISION r 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431-3 tiZI Approved per applicable codes. El Corrections required prior to approval. COMMENTS: te, 7, Inspecto Ott <J /Cv (Date: 7 $58. EINSPECTION }tE E REQUIRED. Prior o inspection. fe u / st be paid at 6300 Southcenter Btvd., Suite 100. Call the schedule reinspection. (Receipt No.: Date: Project: �'' Sf // /T/ J � . Z1 /F ?/ Type of Inspection: / ' -5.-A-5.-A. 171/2:9 ' ,pP/1 /! / ,nrilyT Address: /720r, Send/re-,t/r,- »y Date Called: Special Instructions: Date Wanted: //— / O � Lams, . p.m. Requester: Phone No: 5'o5 -9 -2 z- INSPECTION RECORD Retain a copy with permit INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 0 Approved per applicable codes. El Corrections required prior to approval. COMMENTS: (9 ri O /1r)SAi✓9?/ CA/ />- . r 2 s/- / ri .00 REINSPECTION FE: REQUIRE ) . or to inspection, fee must be • aid at 6300 Southcenter B d., Suite 100. Call to sechedule reinspection. Receipt No.: Date: Project: / ¶ch,l ,',� -/ ,S 2 /A Type of Inspection: - Pre/' / a / < -Vr // T 1 Address: .( /n� r (_ /72 541t14'P.v Y Date Called: Special Instructions: Date Wanted: //- /— CI C"" a.m. P.m. Requester: Phone No: .565' -953- 2631 INSPECTION RECORD Retain a copy with permit /oG -3s / INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)4 -3670 El Approved per applicable codes. PERMIT N Corrections required prior to approval. COMMENTS: P �- OTTU /2C?SGn/rr4., ,tn/ Sr rs >C r r ` Jd1G . 8.00 REINSPECTIO EE REQUIREior to inspection, fee must be paid at 6300 Southcenter Blvd., Su t S: Pro 100. Call to sechedule reinspection. Receipt No.: Date: 09/11/2007 15:16 2067232221 August 15, 2007 City of Tukwila Building Department 6200 Southcenter Boulevard Tukwila, Washington 98168 Project: Southcenter Square Building 5 Address: 17200 Southcenter Parkway, Tukwila Sincerely, OTTO ROSENAU & ASSOCIATES, INC. 5G Susan Rosenau -Moser Vice President Email c: Wig Properties Attn: Mike Weflen OTTO ROSENAU PAGE 02/02 OTTO ROSENAU & ASSOCIATES, INC. Geotechnlcal Engineering, Construction Inspection & Materials Testing 6747 M. L. King Way South, Seattle, Washington 961183216 USA TN: (206) 725-4600 • TcIt Free: (888) OTTO-4-US • Fax: (206) 723 - 2221 WBE W2F5913554. WADO Registered Agency • Wabsfs: www.attarasendu.com Permit Number(s): DO6 -351, D06 -416 Job Number: 06 -683 We state that the work requiring special inspection was, to the best of our knowledge, in conformance with the approved plans and specifications and the applicable workmanship provision of the building code. Our knowledge is limited to our reports. All typewritten reports have been mailed to your office or are enclosed. All reports appear to be complete. This report should not be considered as a warranty for conditions and/or details of the building. Items inspected are: 1. Reinforcing steel 2. Reinforced concrete 3. Reinforced masonry 4. Structural steel erection to include welding and high strength bolts 5. Epoxy grouting 6. Anchor bolt installation 7. Lateral framing 8. Grout under panels/columns GEOTECH CONSULTANTS, INC. Wig Properties 4811 — 134th Place Southeast Bellevue, Washington 98006 Attention: M.K. Wig Subject: Summary of Geotechnical Observations and Testing During Building Pad Preparation North Building (Permit Nos. D06 -387 and D06 -457), South Building (Permit Nos. D06 -351 and D06 -416) and East Building (Permit Nos. D06 -377 and DO6 -384) Southcenter Square 17200 Southcenter Parkway Tukwila, Washington Dear Mr. Wig This letter summarizes the geotechnical observations and testing that our firm completed during the preparation of the foundation and slab subgrades for these three buildings on the Southcenter Square project. Our personnel observed the excavation for the subgrade areas, and placement and compaction of structural fill, in addition to conducting density tests on the structural fill. In accordance with the recommendations of our previous geotechnical report, the foundations for the new buildings were supported on at least 2 feet of structural fill compacted to a minimum 95 percent of the maximum Modified Proctor (ASTM D -1557) dry density. The lower one foot of this structural fill consisted of on -site soils, while the upper one foot was compacted crushed concrete. The structural fill was compacted in lifts to a dense condition. Underlying the structural fill was the previously placed, well - compacted fill that covers the entire project site. Based on our observations, and density tests, the building pads for these two buildings were prepared in conformance with our recommendations and are acceptable for support of both foundations and floor slab cc: Mike Wefflen via facsimile (206) 575 -6680 LEA@ 10125!., 1 via email monwig @wigproperties.com Respectfully submitted, GEOTECH CONSULTANTS, INC. 0 9 � S Marc R. McGinnis, P.E. Principal GEOTECH CONSULTANTS, INC. 13256 Northeast 20th Street, Suite 16 Bellevue, Washington 98005 (425) 747 -5618 FAX (425) 747 -8561 September 5, 2007 JN 04318 ULF LI, turf u0:3( GEOTECH CONSULTANTS, INC. Wig Properties 4811 — 134th Place Southeast Bellevue, Washington 98006 MRM: jyb 447 /4!0701 l]CU t CU" If any questions, please contact me at (425) 747-5618 t.ggspectfuly submitted, GEOTECH CONSULTANTS, INC. . Marc R. McGinnis, P.E. slat /. Principal c 7 GEOTECH CONSULTANTS, INC. 13256 Northeast 206 Street, Suite 16 Bellevue, Washington 98005 (425) 747 -5618 FAX (425) 747 -8561 February 28, 2007 .IN 04318 1:0(0 St 3� �- 3 LIG+ 3G '1Ib Attention: M.K. Wig Subject Foundation Drains Southcenter Square 17200 Southcenter Parkway Tukwila, Washington Dear Mr. Wig: via email We understand that the City of Tukwila is requesting a clarification regarding the potential need for footing drains around the proposed buildings. Per our Geotechnical Engineering Report dated June 20, 2008, Page 12: 'Foundation drains should be used where (1) crawl spaces or basements will be below the structure, (2) a slab is below the outside grade, or (3) the outside grade does not slope downward from a building. A drain on the outside of the foundation must be Installed where there are truck wells to collect drainage flowing under the granular fill below the pavement. Drains should also be placed at the base of all earth - retaining wails...' Based on the above Information, a footing drain should not be required around the perimeter at most, or all, locations, as we understand the finished floor slab elevations are above the surround- ing finished grades. RECEIVED FEB c 7 2007 DEPARTMENT T 08 -30 -2007 LESHYA WIG 4811 134 PL SE BELLEVUE WA 98006 RE: Permit No. D06 -351 17200 SOUTHCENTER PY TUICW Dear Permit Holder: In reviewing our current records the above noted permit has not received a final inspection by the City of Tukwila Building Division. Per the International Building Code and/or the International Mechanical Code, every permit issued by the Building Division under the provisions of this code shall expire by limitation and become null and void if the building or work authorized by such permit is not commenced within 180 days from the date of such pennit, or if the building or work authorized by such permit is suspended or abandoned at any time after the work is commenced for a period of 180 days. Based on the above, you are hereby advised to: Call the City of Tukwila Inspection Request Line at 206 -431 -2451 to schedule for the next or final inspection. This inspection is intended to determine if substantial work has been accomplished since issuance of the permit or last inspection; or if the project should be considered abandoned. If such determination is made, the Building Code does allow the Building Official to approve one or more extensions of time for additional periods not exceeding 90 days each. Extension requests must be in writing and provide satisfactory reasons why circumstances beyond the applicants control have prevented action from being taken. In the event you do not call for the above inspection and receive an extension prior to 10/24/2007 , your permit will become null and void and any further work on the project will require a new permit and associated fees. Thank you for your cooperation in this matter. Sincerely, Je/nuifer Marshall, Permit Technician xe: Permit File No. D06-351 City of Tukwila Steven M. Mullet, Mayor Department of Community Development Steve Lancaster, Director 6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone: 206- 431 -3670 • Fax: 206- 431 -3665 April 27, 2007 Leshya Wig Wig Properties, LLC 4811 134 Pl SE Bellevue WA 98006 City of Tukwila Steven M. Mullet, Mayor Department of Community Development Steve Lancaster, Director RE: Request for Extension Development Permit No. D06 -351, D06 -359 & D06 -387 Wig Properties —17200 Southcenter Py Dear Ms. Wig: This letter is in response to your written request for an extension to Permit Numbers D06 -351, D06 -359, and D06 -387. The Building Official has reviewed your letter and considered your request to extend the above referenced permits. The City of Tukwila Building Division will be extending the expiration date of D06 -351 and D06 -387 for an additional 180 days (through October 24, 2007). Permit D06 -359 is not being extended at this time since the discussion provided in your request did not apply to this permit. If you should have any questions, please contact our office at (206) 431 -3670. Sincerely, 1•• ifek arshall t echnician File: Permit No. D06 -351, 359, 387 P:VennifevExnnsion LeUen\Pennits12006\1306 -351, 359, 387 Pemm Extensioadoc Page 1 of 1 6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone: 206 - 431 -3670 • Fax: 206- 431 -3665 % Wig Properties, LLC 4811 134 Place SE, Bellevue WA 98006 Tel: 425- 747 -8540, Fax: 425- 865 -8648 April 12, 2007 N /A- - D 4tila RE: Permit Extension for D06-351006-3;9)D06-387 D06 -387 17200 Southcenter Parkway Tukwila, WA Mr. Bob Benedicto City of Tukwila Dear Mr. Benedicto, We recently received three letters from the City of Tukwila notifying us that the above referenced permits will expire later this month. 1 am writing to request an extension for these permits. Although the north and south slabs were poured many months ago, the pour strips at the perimeter of these buildings were left open. Most of the pour strip area on the north and south slabs were then poured at the end of March. Our concrete inspector waits 28 days after their last pour before issuing their inspection report. My understanding is that this inspection report is required to call in a fmal inspection to the City. For your information, the pour strips on the east end of these buildings (where the sewer line goes in) on the north and south buildings will not be poured until the time of completing the individual tenant improvements. Please let me know if the City prefers that we complete the finals on the north and south slab as soon as we receive the inspection report or if the City would like us to wait until the entire pour strips have been completed. Thank you for your help on this matter! Sincerely // � ^A Leshya Wig Wig Properties, LLC (425) 957-4774 Yi 0(, S I 61 i tsfro al) 3ji r Rfi R .� %�i� oft cw peovil4 kob 351 amt t o& -387 c4 -/7 -2W 7 Crty p wKw APR 1 3 2007 FERR cevriA 04 -05 -2007 LESHYA WIG 4811 134 PL SE BELLEVUE WA 98006 RE: Permit No. D06 -351 17200 SOUTHCENTER PY TUKW Dear Permit Holder: In reviewing our current records the above noted permit has not received a final inspection by the City of Tukwila Building Division. Per the International Building Code and/or the International Mechanical Code, every permit issued by the Building Division under the provisions of this code shall expire by limitation and become null and void if the building or work authorized by such permit is not commenced within 180 days from the date of such permit, or if the building or work authorized by such permit is suspended or abandoned at any time after the work is commenced for a period of 180 days. Based on the above, you are hereby advised to: Call the City of Tukwila Inspection Request Line at 206- 431 -2451 to schedule for the next or final inspection. This inspection is intended to determine if substantial work has been accomplished since issuance of the permit or last inspection; or if the project should be considered abandoned. If such determination is made, the Building Code does allow the Building Official to approve one or more extensions of time for additional periods not exceeding 90 days each. Extension requests must be in writing' and provide satisfactory reasons why circumstances beyond the applicants control have prevented action from being taken. In the event you do not call for the above inspection and receive an extension prior to 05/13/2007 , your permit will become null and void and any firrther work on the project will require a new permit and associated fees. Thank you for your cooperation in this matter. Sincerely, fer Marshall, Permit Technician xc: Permit File No. D06 -351 Steven M. Mullet, Mayor Department of Community Development Steve Lancaster, Director 6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone: 206-431-3670 • Fax: 206 - 431 -3665 ACTIVITY NUMBER: D06 -351 DATE: 09 -25 -06 PROJECT NAME: WIG PROP, SOUTH BLDG, FOUND ONLY SITE ADDRESS: 17200 SOUTHCENTER PY X Original Plan Submittal Response to Incomplete Letter # Response to Correction Letter # Revision # After Permit Issued DEPARTMENTS: �" Bu - g n ion Public Works N� 1 4- -DO DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete Comments: Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: TUES/THURS RONG: Please Route LE Structural Review Required REVIEWER'S INITIALS: APPROVALS OR CORRECTIONS: Approved ❑ Approved with Conditions Notation: REVIEWER'S INITIALS: Documents/routing slip.doc 2 -28-02 PERMIT COORD COPY '•-' PLAN REVIEW /ROUTING SLIP Fire Prevention I Structural Incomplete ❑ DUE DATE: 09-26-06 DATE: DATE: Plannin t ivision Permit Coordinator ❑ Not Applicable ❑ No further Review Required DUE DATE: 10-24-06 Not Approved (attach comments) ❑ Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: License Information License WIGPRPL945N3 Licensee Name WIG PROPERTIES LLC -SS Licensee Type CONSTRUCTION CONTRACTOR UBE 602392950 Ind. Ins. Account Id PARTNER/MEMBER Business Type LIMITED LIABILITY COMPANY Address 1 4811 134TH PL SE Address 2 City BELLEVUE County KING State WA Zip 98006 Phone 4256412044 Status ACTIVE Specialty 1 GENERAL Specialty 2 UNUSED Effective Date 8/23/2006 Expiration Date 8/23/2008 Suspend Date Separation Date Parent Company Previous License SEATADC016JH Next License Associated License Business Owner Information Name Role Effective Date Expiration Date WIG, MANMOHAN K PARTNER/MEMBER 08/23/2006 WIG, PRISCILLA P PARTNER/MEMBER 08/23/2006 Look Up a Contractor, Electrician or Plumber License Detail Page 1 of 2 Washington State Department of Labor and Industries General/Specialty Contractor A business registered as a construction contractor with L&I to perform construction work within the scope of its specialty. A General or Specialty construction Contractor must maintain a surety bond or assignment of account and carry general liability insurance. Bond Information Bond Bond Company Name Bond Account Effective Number Date Expiration Date Cancel Date Impaired Date Bond Amount Received Date TRAVELERS https: / /fortress wa.gov/lni/bbip / printer .aspx?License= WIGPRPL945N3 10/20/2006 x x x x