Loading...
HomeMy WebLinkAboutPermit D06-369 - Best Western - FrontageBESTWESTERN 15901 WEST VALLEY HY D06 -369 Value of Construction: $173,000.00 Type of Fire Protection: Type of Construction: City dr'Tukwila Parcel No.: 0005800030 Address: 15901 WEST VALLEY HY TUKW Suite No: Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: ci.tukwila.wa.us Tenant: Name: BEST WESTERN Address: 15901 WEST VALLY HY, TUKW ILA WA DEVELOPMENT PERMIT Owner: Name: LIU SHUH -WEN +KIN -LUAN CHEN Address' NENDELS SOUTHCENTER, 15901 W VALLEY, TUKWILA WA 98188 Phone: Contact Person: Name: SOOZEE KIM Address: 16212 BOTHELL EVERETT HY, F271, MILL CREEK WA, 98012 Phone: 253 970 -9565 "continued on next page" Permit Number: D06 -369 Issue Date: 10/18/2006 Permit Expires On: 04/16/2007 Contractor: Name: DELTA WORLD LLC Address: 16212 BOTHELL EVERETT HWY F 271, MILL CREEK WA 98012 Phone: 425 835 -0002 Contractor License No: DELTAWL941BR Expiration Date:02 /28/2008 Steven M. Mullet, Mayor Steve Lancaster, Director DESCRIPTION OF WORK: NEW FACE FOR FRONT OF BUILDING, STUCCO FINISH, NEW PAINTING, WINDOWS, NEW SIDEWALK, AND NEW ROOFTO ENCLOSURE. Fees Collected: $4,023.19 International Building Code Edition: 2003 Occupancy per IBC: 0020 doc: IBC - PERMIT D06 -369 Printed: 10-18 -2006 Public Works Activities: Channelization / Striping: N Curb Cut / Access / Sidewalk / CSS: N Fire Loop Hydrant: Flood Control Zone: Hauling: Land Altering: Landscape Irrigation: Moving Oversize Load: Sanitary Side Sewer: Sewer Main Extension: Storm Drainage: Street Use: Water Main Extension: Water Meter: Permit Center Authorized Signature:, I hereby certify that I have read and ordinances governing this work will b Print Name: doc: IBC - PERMIT City isiti Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 - 3670 Fax: 206 - 431 - 3665 Web site: cttukwila.wa.us N N N Permit Number: D06 -369 Issue Date: 10/1812006 Permit Expires On: 04/16/2007 Number: 0 Size (Inches): 0 Start Time: End Time: Volumes: Cut 0 c.y. Fill 0 c.y. Start Time: End Time: Private: Public: Profit: N Non - Profit: N Private: Public: Steven M. Mullet, Mayor Steve Lancaster, Director Date: ID( 1 is permit and know the same to be true and correct. All provisions of law and with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this development permit. Signature: , Date: In It j - (d "j — SCIZEr This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. 006 -369 Printed: 10-18 -2006 Cr/ 10 : :TO; -. -;\ :ENT OEPT.OFG.::'.: :.i1 C 6300 £.,U ([ „ " D. TUKVAL.A, VIA h • .3 PERMIT CONDITIONS Parcel No.: 0005800030 Permit Number: D06 -369 Address: 15901 WEST VALLEY HY TUKW Status: ISSUED Suite No: Applied Date: 10/03/2006 Tenant: BEST WESTERN Issue Date: 10/18/2006 1: ***BUILDING DEPARTMENT CONDITIONS*** PERMIT CENTER 2: All permits, inspection records, and approved plans shall be at the job site and available to the inspectors prior to start of any construction. These documents shall be maintained and made available until final inspection approval is granted. 3: All construction shall be done in conformance with the approved plans and the requirements of the International Building Code or International Residential Code, International Mechanical Code, Washington State Energy Code. 4: All electrical work shall be inspected and approved under a separate permit issued by the Washington State Department of Labor and Industries (206/248- 6630). 5: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. 6: ***FIRE DEPARTMENT CONDITIONS*** 7: The attached set of building plans have been reviewed by the Fire Prevention Bureau and are acceptable with the following concerns: 8: Maintain sprinkler coverage per N.F.P.A. 13. Addition/relocation of walls, closets or partitions may require relocating and /or adding sprinkler heads. (IFC 901.4) 9: All new sprinkler systems and all modifications to existing sprinkler systems shall have fire department review and approval of drawings prior to installation or modification. New sprinkler systems and all modifications to sprinkler systems involving more than 50 heads shall have the written approval of the W.S.R.B., Factory Mutual, Industrial Risk Insurers Kemper or any other representative designated and /or recognized by the City of Tukwila, prior to submittal to the Tukwila Fire Prevention Bureau. No sprinkler work shall commence without approved drawings. (City Ordinance #2050) 10: Means of egress, including the exit discharge, shall be illuminated at all times the building space served by the means of egress is occupied. The means of egress illumination level shall not be less than 1 foot - candle (11 lux) at the floor level. The power supply for the means of egress illumination shall normally be provided by the premise's electrical supply. In event of a power failure an emergency power system shall provide power for a duration of not less than 90 minutes and shall consist of storage batteries, unit equipment or on -site generator. (IFC 1006.1, 1006.2, 1006.3) 11: Maintain square foot coverage of detectors per manufacturer's specifications in all areas including: closets, elevator shafts, top of stairwells, etc. (NFPA 72- 5.5.2.1) 12: Maintain automatic fire detector coverage per N.F.P.A. 72. Addition /relocation of walls, closets or partitions may require relocating and /or adding automatic fire detectors. doe: Conditions D06 -369 Printed: 10 -18 -2006 CIO' O:TO; 7 "A DEPT. OF CC :... - iYC.:�. ^ 2 7 .:IT 6300 C ,UfFI: 4iL2CLVD. TUKWILA, WA 93188 PERMIT CENTER 13: Maintain fire alarm system audible/visual notification. Addition /relocation of walls or partitions may require relocation and /or addition of audible/visual notification devices. (City Ordinance #2051) 14: All new fire alarm systems or modifications to existing systems shall have the written approval of The Tukwila Fire Prevention Bureau. No work shall commence until a fire department permit has been obtained. (City Ordinance #2051) (IFC 104.2) 15: Contact The Tukwila Fire Prevention Bureau to witness all required inspections and tests. (City Ordinances #2050 and #2051) 16: Any overlooked hazardous condition and /or violation of the adopted Fire or Building Codes does not imply approval of such condition or violation. 17: These plans were reviewed by Inspector 511. If you have any questions, please call Tukwila Fire Prevention Bureau at (206)575 -4407. 18: ***PLANNING DIVISION*** 19: The City is NOT approving the removal of any trees within the shoreline zone under this permit. If the applicant wishes to remove trees, a tree clearing permit will be required by the Department of Community Development. doc: Conditions * *continued on next page** 006 -369 Printed: 10 -18 -2006 6i W ,JiIIJ.JdiLkL TUKWILA. WA 98188 I hereby certify that I have read these conditions and will comply with them as outlined. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provision of any other work or local laws regulating construction or the performance of work. Signature: Print Name: OVZ < Wm `, PERMIT CENTER Date: \'O A ( o — 6 doc: Conditions D06 -369 Printed: 10-1 8-2006 SITE LOCATION TION Company Name: VITA_ 1l,30vtok (' C Mailing Address: ( A i "Ertk rest-* Wot t Contact Person: cat I. Pee E -Mail Address: bXI p4c,%% 6 COka Contractor Registration Number: trt 'AL0 L 943 BP- Company Name: - 412y c Mailing Address: 'SO 44-h /'t'le S Contact Person: E -Mail Address: ' Company Name: Mailing Address: CITY OF TUKWILA Community Developmercw)epartment Public Works Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http: / /www. c i. t ukwi l a. wa. us Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. •'Please Print'• -r—Ate,nytt A-6604— King Co Assessor's Tax No.: Circle - 00 Site Address: t l)1 V) V G J1e 41- �UI) C Loehr ,4 Nmber: Tenant Name: V `i`C i t New Tenant: Property Owners Name: yr,rt9- c'14-0 • Mailing Address: ttint si V11.1.1-- Sent P �1JT cri��R' - ty State Floor: ....Yes El ..No CONTACT PERSON = who do we contact when your permit is ready be liiaed Name: :source vi. l Day Telephone: 2. - a ✓ -c i9D "1-. Mailing Address: thala en .he(% A 1- F711 MVl (tact (ifS- /eel �. City State Zip E -Mail Address: t rTPrDO f TlO MOt$i- t t•tc - 1 - Fax Number: . GENERAL CONTRACTOR INFORMATION - • - ;. (Contractor Information' for Mechanical (pg 4).for Plumbing and Gas Piping (pg 5)) M2U C P t — e k c w i - cj t t City State Zip Day Telephone: 2bS - 97o -` it Fax Number: Expiration Date 1 ARCIIITECTOF RECORD All plans must be wet stamped by Architect of Recoil (.JA 9 R l3 q City State Zip Day Telephone: D. mec / , Fax Number: Zob- - 9 3 ENGINEER OF RECORD - All plans must be wet stamped by Engineer otRecord State Zip Zip City Contact Person: Day Telephone: E -Mail Address: Fax Number: Q:UppliationsWo,ms- Appliations On Lin63.2006 - Permit Appliation.doe Revised. 9-2006 bh Page 1 of 6 �, ti ' a E s lnterlorRemodel, Addttton Io xisaag .. „Structure . ` n f j t i "ype of C,onstru riper Ili ." !, ' ge of Occupancy ;IEC Basemeut Armory Sun x "•,''' Y ��i �vW �' fk$y F4 l+f'Pf°X _ h Attached Garage httacted C x 4 i t Detached prt ° ! F i Covered ek' s'" t ! iy Uncovered Deck t rt Valuation of Project (contractor's bid price): $ I1 , 0 .. _ , __ _ Existing Building Valuation: $ Scope of Work (please provide detailed information): pta r-e �,r Ftten tzl.,l lot ;i cco P n7 t 5'11- • — Will there be new rack storage? ❑.... Yes p2 ostlY - Number of Parking Stalls Provided: Standard: Q:Upplicetiotu\Fonms- Application On Line V -2006 - Permit Applicationdoc Revised: 9 -2006 bh w 4.. No If yes, a separate permit and plan submittal will be required. PLANNING DIVISION: Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) For an Accessory dwelling, provide the following: Lot Area (sq ft): Floor area of principal dwelling: Floor area of accessory dwelling: *Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Compact: Handicap: Will there be a change in use? ❑ Yes ❑ No If "yes ", explain: FIRE PROTECTION/HAZARDOUS MATERIALS: g Sprinklers g Automatic Fire Alarm ❑ None ❑ Other (specify) Will there be storage or use of flammable, combustible or hazardous materials in the building? ❑ Yes ❑ No If "yes', attach list of materials and storage locations on a separate 8 -1/2 "x 11" paper including quantities and Material Safety Data Sheets. SEPTIC SYSTEM ❑ On -site Septic System — For on -site septic system, provide 2 copies of a current septic design approved by King County Health Department. Page 2 of 6 Fixture Type: Qty Fixture Type: Qty Fixture Type: Qty Fixture Type: ` Qty Bathtub or combination bath/shower Drinking fountain or water cooler (per head) Wash fountain Gas piping outlets Bidet Food -waste grinder, commercial Receptor, indirect waste Clothes washer, domestic Floor drain Sinks Dental unit, cuspidor Shower, single head trap Urinals Dishwasher, domestic, with independent drain Lavatory Water Closet Building sewer or trailer park sewer Rain water system — per drain (inside building) Water heater and/or vent Additional medical gas inlets/outlets — six or more Industrial waste pretreatment interceptor, including its trap and vent, except for kitchen type grease interceptors Repair or alteration of water piping and/or water treating equipment Repair or alteration of drainage or vent piping Medical gas piping system serving one to five inlets/outlets for specific gas PLUMBING AND GAS PIPING °ERMIT INFORMATION - 2064311 - ; PLUMBING AND GAS PIPING CONTRACTOR INFORMATION Company Name: Mailing Address: City State Zip Contact Person: Day Telephone: E -Mail Address: Fax Number: Contractor Registration Number: Expiration Date: s Valuation of Plumbing work (contractor's bid price): $ Valuation of Gas Piping work (contractor's bid price): $ Scope of Work (please provide detailed information): Building Use (per Int'I Building Code): Occupancy (per Int'I Building Code): Utility Purveyor: Water: Sewer: Indicate type of plumbing fixtures and/or gas piping outlets being installed and the quan ity below: Q:tApplicetknaonn - Application On LineU -2006 - Permit Application doc Reviled: 9-2006 bit Page 5 of 6 Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. Building and Mechanical Permit The Building Official may grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). Plumbing Permit The Building Official may grant one extension of time for an additional period not exceeding 180 days. The extension shall be requested in writing and justifiable cause demonstrated. Section 103.4.3 Uniform Plumbing Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OR _ HORIZED AGENT: Signature: Mailing Address: Print Name: I Date Application Accepted: Q. Applications\Fmms- Applications On Line\3 -2006 - Permit Appliation.doc Revised: 9-2006 bh City Date: Day Telephone. r)0 State Zip Date Application Expires: to-1fiO Staff Initials: Page 6 of 6 Payee: ACCOUNT ITEM LIST: Description Current Pmts City of Tukwila 6300 Southcenter BL, Suite 100 / Tukwila, WA 98188 / (206) 431 -3670 Parcel No.: 0005800030 Permit Number: D06 -369 Address: 15901 WEST VALLEY HY TUKW Status: APPROVED Suite No: Applied Date: 10/03/2006 Applicant: BEST WESTERN Issue Date: Receipt No.: R06 -01671 Payment Amount: 2,193.10 Initials: JEM Payment Date: 10/18/2006 02:42 PM User ID: 1165 Balance: 50.00 .as BANE( li e jUb Iu TRANSACTION LIST: Type Method Description Amount Payment Check 50364851 2,193.10 BUILDING - NONRES PW PERMIT /INSPECTION FEE STATE BUILDING SURCHARGE RECEIPT Account Code 000/322.100 000/342.400 000/386.904 1,738.60 450.00 4.50 Total: 2,193.10 0860 10/18 9716 TOTAL 2193.10 doc: Receipt Printed: 10-18 -2006 ACCOUNT ITEM LIST: Description Current Pmts City of Tukwila 6300 Southcenter BL, Suite 100 / Tukwila, WA 98188 / (206) 431 -3670 Parcel No.: 0005800030 Permit Number: D06 -369 Address' 15901 WEST VALLEY HY TUKW Status: PENDING Suite No: Applied Date: 10/03/2006 Applicant: BEST WESTERN Issue Date: Receipt No.: R06 -01552 Payment Amount: 1,830.09 Initials: JEM Payment Date: 10/03/2006 11:32 AM User ID: 1165 Balance: 52,193.10 Payee: DELTA WORLD, LLC TRANSACTION LIST: Type Method Description Amount Payment Check 7126 1,830.09 PLAN CHECK - NONRES PW BASE APPLICATION FEE PW PLAN REVIEW RECEIPT Account Code 000/345.830 000/322.100 000/345.830 1,130.09 250.00 450.00 Total: 1,830.09 0344 10/03 9716 TOTAL 1830.09 doc: Receipt Printed: 10 -03 -2006 Projec k 19, W ✓ilk Type of Inspection: / - . / n/.7 Address: /57 /( /,5 109 // may Date Called: /lt Special Instructions: / Date Wraht5dz� c f > / — e C7 Ca Vim. Requester: '2OL ,, — g5/ S INSPE ION NO. INSPECTION RECORD Retain a copy with permit CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., E 00, Tukwila, WA 98188 v0‘- pproved per applicable codes. ❑ Corrections required prior to approval. COMMENTS: ,de° K r / . U*9 / .00 REINSPECTIONIFEE REQUIR Prior to inspection. fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call the schedule reinspection. 'Receipt No.: 'Date: COMMENTS: i ) /& &rl // --SA,-,414r,?, _. /-2/7/7!✓c/ Type of Inspection: elx7/. GJ�i /e� :2 2 FP An u /rtf, — r7/9"//✓Y 11/9 __ J f -. 61 /7dh rtf r 4 fr i p 7 to Date Called: /c -5 Special Instructions: Date WantJed: G.rtk / c — / " c7 p.m. Requester: Project: 6 -5 -/ CJisli�n/ Type of Inspection: elx7/. GJ�i /e� Address: A..5 0 / 4-2.3 11/9 /. y pi Date Called: /c -5 Special Instructions: Date WantJed: G.rtk / c — / " c7 p.m. Requester: Phone No 2o 6- 3°r -Y� /S INSPECTION RECORD Retain a copy with permit INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 ED Approved per applicable codes. ctor: El Corrections required prior to approval. Date: / 7 ' / - 0' $58.00 REINSPECT! CIN FEE REQUIRED. Prior o inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call the schedule reinspection. (Receipt No.: 'Date: (206)431 -3 Proje t: gi x°5 11 Oti ° stt°rn/ Type of Inspection: pxi. CJ.I// del A PA Address: iSSo/ wets] (J,9 / /ft. Date Called: Special Instructions: Date Wanted: /7- a.m. p. Requester: Phone No: 7 INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERM CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3 Approved per applicable codes. /JO -y(29 Corrections required prior to approval. COMMENTS: 7 ; ) 5 7 2' ; F o / L/4- lie" s1 e -ells O 6 Ot i /fin / t ) /. w dy/ - ��? 58.00 REINSPECTION FE REQUIRED(Prior to inspection, fee must be paid at 6300 Southcenter vd., Suite 100. Call to sechedule reinspection. (Receipt No.: Date: 1 Project: IS /(45f�iN Type of In pection: g�I. W9 /Gdh Address: /5 g in / ws [ l l , 4 /e� Ny Date Called: Special Instructions: Date Wanted: c� /07-- /9-o4* p.m. Requester: Phone No: a 53- 5' 7v 9S65 6 INSPECTION RECORD Retain a copy with permit 0 Approved per applicable codes. INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (2 PERM 6)431 -367 El Corrections required prior to approval. COMMENTS: 80hce. -, sA,gj eel/ ed 77i to f z t - O45T lnsp Date: /2• (2_6, $j8,40 REINSPECTION FEE REQUIRED�or to inspection, fee must be p d at 6300 Southcenter Blvd., Suite 100. Call to sechedule reinspection. Receipt No.: !Date: Projeft: /7 f�jfGf%r� �f / /j� Type of Inspection : 7 7 \ 4 Address• / � ( —tr., /a4/4 Date Called: Special Instructions: Date Wa ted: a.m. Requester: Phone No: Approved per applicable codes. INSPECTION RECORD Retain a copy with permit /90 C INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -367 PERMIT NO. Ej Corrections required prior to approval. COMMENTS: O C fr- /7 P✓ 5-<ie1 /,_),, I ,'h 7e / /_ A - h A - <f' , 4 .7) 7i) /mi." - pzeLad Date: /Z /Z' 58.00 REINSPECTION FEE REQUI . Prior to inspection, fee must be paid at 6300 Southcenter Blvd., ite 100. Call to sechedule reinspection. Receipt No.: (Date: COMMENTS: ` /i,� r4 , 57 ._ 5T - ie if//S ) '��y( 1 /� if -U 6 r t on 5 A-- er to ogelc/ s -� .*P, S Ate/ P ev 41`41/4/3 t Date Called �te- C 4.'4-14 iLv / 2) (P0 0 F'/a /1 144,c/-0 i t r -to Phone No: an - 9 o- -ysti Project - Type of Inspection: v Add / 64/,' .4A-1 Date Called Special Instructions: / Date Wanted: Vim //- 7..i �l �"n' Requester: Phone No: an - 9 o- -ysti INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 Approved per applicable codes. n ect r 1444. t, f A.d=L 0 8.00 REINSPECTIbN FEE RE RED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to sechedule reinspection. !Receipt No.: INSPECTION RECORD Retain a copy with permit (206)431 -3 M e Corrections required prior to approval. Date: /l. z; Date: Project: e�Si Gc1rS /-r,- Type of Inspection: �-' / A An A Al 4 Address: /590/ eci <5-I v? // y be Date Called: 9 Special Instructions: Date Wanted: /7- VG - L a�.m "'�• Requester: Phone No: 53— c 320 — S 565 INSPECT O NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -'6 0 Approved per applicable codes. INSPECTION RECORD Retain a copy with permit .Gb6- 36 S PERMIT NO. Corrections required prior to approval. COMMENTS: 7i — All (c✓/ fiti /l Grtu. 1 specto . 0 $ f . REINSPECTION FEE QUIRED. or to inspection, fee must be d at 6300 Southcenter Blvd., Suite 100. Call to sechedule reinspection. }Receipt No.: Date: COMMENTS:. n .4 P. Type of Inspection: / r / - l/- 7//6d4 e 6 ) 11 /S7 2 r /rB s c,17t/ - apPPwP/) Special Instructions: / Date Wanted: // - /3 (A // rev 4,,..a a eve 3./ / /ctn/ Phone No: a 53 570 -9S& r Project: % ✓ ect: ! G/ / /Piv 4Fs rs P. Type of Inspection: / r / - l/- 7//6d4 e Address: /S90/ Gt/r3 !/19/16 /1? Date Called: Special Instructions: / Date Wanted: // - /3 -0 G p.m. Requester: Phone No: a 53 570 -9S& CITY OF TUKWILA BUILDING DIVISIO 6300 Southcenter Blvd., #100, Tukwila, WA 98188 El Approved per applicable codes. Receipt No.: Date: INSPE TCNO. INSPECTION RECORD Retain a copy with permit (206)431 -$1570 El Corrections required prior to approval. Date: / / /3 — d /_ .00 REINSPECTION FE1r REQUIRE or to inspection, fee must be id at 6300 Southcenter Blvd., Suite 100. Call to sechedule reinspection. Project: if -s-{ t "� esAo,,/ Type of In ection: WrinNr '7'd 41m-'t Address: /550, actiGrimy Date Called: Special Instructions: / ate Wanted: : m. /O — /9 - 6 m. Requester: Phone No: o2S SM -S s6S. INSPECTION RECORD Retain a copy with permit INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 Do 6- 362 PERMIT NO. Approved per applicable codes. El Corrections required prior to approval. COMMENTS: a Stoic W vic t i2e fr a1 el Date: _ OC .00 REINSPECTION FEE \EQUIRED. ' r to Inspection, fee must be paid at 6300 Southcenter Bl., Suite 100. Call to sechedule reinspection. !Receipt No.: !Date: wr. 1 'IS SWENSON SAY FACET A STRUCTURAL ENGINEERING CORPORATION 932 Broadway • Tacoma • WA 92902 Office: 253.284-9970 fax: 253.284.9971 F112 COPY Perrit r!". 54. 3176 ` NAL W BrgiEiiTlie 1.41A ''S 'tgo)airl • Awl-Len' • _ d€ ±4 • l e•=e Protect REVIEWED FOR CODE COMPLIANCE ,s000nuto OCT 1 3 2006 __fi54t;r City Of TUkwila BUILDING DIVISION ofr Da PP* tea Design Sheet ae TUKWILA BEST WESTERN PORTE' COCHERE GENERAL STRUCTURAL NOTES (The following apply unless shown otherwise on the plans) CRITERIA S1A. ALL MATERIALS, WORKMANSHIP, DESIGN, AND CONSTRUCTION SHALL CONFORM TO THE DRAWINGS, SPECIFICATIONS, THE 2003 SEATTLE BUILDING CODE. 1B. ALL MATERIALS, WORKMANSHIP, DESIGN, AND CONSTRUCTION SHALL CONFORM TO THE DRAWINGS, SPECIFICATIONS, AND THE INTERNATIONAL BUILDING CODE (2003 EDITION). 2. DESIGN LOADING CRITERIA ROOF LIVE LOAD 25 PSF FLOOR LIVE LOAD (RESIDENTIAL) 40 PSF SNOW Pf =25 PSF WIND Iw =1.0, GCpi =0.18, 85 MPH, EXPOSURE "B" EARTHQUAKE . . . ANALYSIS PROCEDURE: EQUIVALENT LATERAL FORCE PROCEDURE LATERAL SYSTEM: LIGHT FRAMED SHEAR WALLS, Vs = 3.29 KIPS SITE CLASS =D, Ss =1.42, Sds =.948, S1 =.486, SD1 =0.49, Cs =0.167 SDC D, Ie =1.0, R =6.5 SEE PLANS FOR ADDITIONAL LOADING CRITERIA 3. STRUCTURAL DRAWINGS SHALL BE USED IN CONJUNCTION WITH ARCHITECTURAL DRAWINGS FOR BIDDING AND CONSTRUCTION. CONTRACTOR SHALL VERIFY DIMENSIONS AND CONDITIONS FOR COMPATIBILITY AND SHALL NOTIFY ARCHITECT OF ANY DISCREPANCIES PRIOR TO CONSTRUCTION. 4. CONTRACTOR SHALL VERIFY ALL EXISTING DIMENSIONS, MEMBER SIZES, AND CONDITIONS PRIOR TO COMMENCING ANY WORK. ALL DIMENSIONS OF EXISTING CONSTRUCTION SHOWN ON THE DRAWINGS ARE INTENDED AS GUIDELINES ONLY AND MUST BE VERIFIED. 5. CONTRACTOR SHALL PROVIDE TEMPORARY BRACING FOR THE STRUCTURE AND STRUCTURAL COMPONENTS UNTIL ALL FINAL CONNECTIONS HAVE BEEN COMPLETED IN ACCORDANCE WITH THE PLANS. 6. CONTRACTOR SHALL BE RESPONSIBLE FOR ALL SAFETY PRECAUTIONS AND THE METHODS, TECHNIQUES, SEQUENCES OR PROCEDURES REQUIRED TO PERFORM THE CONTRACTORS WORK. THE STRUCTURAL ENGINEER HAS NO OVERALL SUPERVISORY AUTHORITY OR ACTUAL AND /OR DIRECT RESPONSIBILITY FOR THE SPECIFIC WORKING CONDITIONS AT THE SITE AND /OR FOR ANY HAZARDS RESULTING FROM THE ACTIONS OF ANY TRADE CONTRACTOR. THE STRUCTURAL ENGINEER HAS NO DUTY TO INSPECT, SUPERVISE, NOTE, CORRECT, OR REPORT ANY HEALTH OR SAFETY DEFICIENCIES TO THE OWNER, CONTRACTORS, OR OTHER ENTITIES OR PERSONS AT THE PROJECT SITE. 7. CONTRACTOR- INITIATED CHANGES SHALL BE SUBMITTED IN WRITING TO THE ARCHITECT AND STRUCTURAL ENGINEER FOR APPROVAL PRIOR TO FABRICATION OR CONSTRUCTION. CHANGES SHOWN ON SHOP DRAWINGS ONLY WILL NOT SATISFY THIS REQUIREMENT. 8. DRAWINGS INDICATE GENERAL AND TYPICAL DETAILS OF CONSTRUCTION. WHERE CONDITIONS ARE NOT SPECIFICALLY INDICATED BUT ARE OF SIMILAR CHARACTER TO DETAILS SHOWN, SIMILAR DETAILS OF CONSTRUCTION SHALL BE USED, SUBJECT TO REVIEW AND APPROVAL BY THE ARCHITECT AND THE STRUCTURAL ENGINEER. TUKWILA BEST WESTERN PORTE' COCHERE GENERAL STRUCTURAL NOTES 10. SHOP DRAWINGS FOR THE FOLLOWING ITEMS SHALL BE SUBMITTED TO THE ARCHITECT AND STRUCTURAL ENGINEER FOR REVIEW PRIOR TO FABRICATION OF THESE ITEMS. GLUED LAMINATED MEMBERS REINFORCING STEEL (FOR BOTH CONCRETE AND MASONRY CONSTRUCTION) STRUCTURAL STEEL APPROVED SETS OF ALL SHOP DRAWINGS SHALL ALSO BE SUBMITTED TO THE BUILDING DEPARTMENT. 11. SHOP DRAWING REVIEW: DIMENSIONS AND QUANTITIES ARE NOT REVIEWED BY THE ENGINEER OF RECORD, THEREFORE MUST BE VERIFIED BY THE CONTRACTOR. CONTRACTOR SHALL REVIEW AND STAMP DRAWINGS PRIOR TO REVIEW BY ENGINEER OF RECORD. CONTRACTOR SHALL REVIEW DRAWINGS FOR CONFORMANCE WITH THE MEANS, METHODS, TECHNIQUES, SEQUENCES AND OPERATIONS OF CONSTRUCTION, AND ALL SAFETY PRECAUTIONS AND PROGRAMS INCIDENTAL THERETO. SUBMITTALS SHALL INCLUDE A REPRODUCIBLE AND ONE COPY; REPRODUCIBLE WILL BE MARKED AND RETURNED WITHIN TWO WEEKS OF RECEIPT WITH A NOTATION INDICATING THAT THE SUBMITTAL HAS BEEN FOUND TO BE IN GENERAL CONFORMANCE WITH THE DESIGN OF THE BUILDING. THE SUBMITTED ITEMS SHALL NOT BE INSTALLED UNTIL THEY HAVE BEEN APPROVED BY THE BUILDING OFFICIAL. SHOP DRAWING SUBMITTALS PROCESSED BY THE ENGINEER ARE NOT CHANGE ORDERS. THE PURPOSE OF SHOP DRAWING SUBMITTALS BY THE CONTRACTOR IS TO DEMONSTRATE TO THE ENGINEER THAT THE CONTRACTOR UNDERSTANDS THE DESIGN CONCEPT, BY INDICATING WHICH MATERIAL IS INTENDED TO BE FURNISHED AND INSTALLED AND BY DETAILING THE INTENDED FABRICATION AND INSTALLATION METHODS. IF DEVIATIONS, DISCREPANCIES, OR CONFLICTS BETWEEN SHOP DRAWING SUBMITTALS AND THE CONTRACT DOCUMENTS ARE DISCOVERED EITHER PRIOR TO OR AFTER SHOP DRAWING SUBMITTALS ARE PROCESSED BY THE ENGINEER, THE DESIGN DRAWINGS AND SPECIFICATIONS SHALL CONTROL AND SHALL BE FOLLOWED. QUALITY ASSURANCE 14. SPECIAL INSPECTION SHALL BE PROVIDED IN ACCORDANCE WITH THE PROJECT SPECIFICATIONS AND SECTIONS 109 AND 1704 OF THE INTERNATIONAL BUILDING CODE BY A QUALIFIED TESTING AGENCY DESIGNATED BY THE ARCHITECT, AND RETAINED BY THE BUILDING OWNER. THE ARCHITECT, STRUCTURAL ENGINEER, AND BUILDING DEPARTMENT SHALL BE FURNISHED WITH COPIES OF ALL INSPECTION AND TEST RESULTS. SPECIAL INSPECTION OF THE FOLLOWING TYPES OF CONSTRUCTION STRUCTURAL STEEL FABRICATION AND ERECTION CONCRETE CONSTRUCTION SOIL CONDITIONS, FILL PLACEMENT, AND DENSITY EXPANSION BOLTS AND THREADED EXPANSION INSERTS EPDXY GROUTED INSTALLATIONS PER TABLE 1704.3 PER SECTION 1704.4 PER SECTION 1704.7 PER MANUFACTURER PER MANUFACTURER TUKWILA BEST WESTERN PORTE' COCHERE GENERAL STRUCTURAL NOTES 15. UNLESS OTHERWISE NOTED, THE FOLLOWING ELEMENTS COMPRISE THE SEISMIC- FORCE- RESISTING SYSTEM AND ARE SUBJECT TO SPECIAL INSPECTION FOR SEISMIC RESISTANCE IN ACCORDANCE WITH SECTION 1707 OF THE INTERNATIONAL BUILDING CODE. B. STRUCTURAL WOOD SHEAR WALL SYSTEMS REQUIRE PERIODIC INSPECTION FOR NAILING, BOLTING, ANCHORING AND OTHER FASTENING OF COMPONENTS WITHIN THE SEISMIC FORCE RESISTING SYSTEM INCLUDING DRAG STRUTS, BRACES AND HOLDOWNS. GEOTECHNICAL 18B. FOUNDATION NOTES: ALLOWABLE SOIL PRESSURE AND LATERAL EARTH PRESSURE ARE ASSUMED AND THEREFORE MUST BE VERIFIED BY A QUALIFIED SOILS ENGINEER OR APPROVED BY THE BUILDING OFFICIAL. IF SOILS ARE FOUND TO BE OTHER THAN ASSUMED, NOTIFY THE STRUCTURAL ENGINEER FOR POSSIBLE FOUNDATION REDESIGN. FOOTINGS SHALL BEAR ON FIRM, UNDISTURBED EARTH AT LEAST 18" BELOW ADJACENT FINISHED GRADE. UNLESS OTHERWISE NOTED, FOOTINGS SHALL BE CENTERED BELOW COLUMNS OR WALLS ABOVE. ALLOWABLE SOIL PRESSURE 2000 PSF COEFFICIENT OF FRICTION (FACTOR OF SAFETY OF 1.5 INCLUDED) 0 3 RENOVATION 21. DEMOLITION: CONTRACTOR SHALL VERIFY ALL EXISTING CONDITIONS BEFORE COMMENCING ANY DEMOLITION. SHORING SHALL BE INSTALLED TO SUPPORT EXISTING CONSTRUCTION AS REQUIRED AND IN A MANNER SUITABLE TO THE WORK SEQUENCES. DEMOLITION DEBRIS SHALL NOT BE ALLOWED TO DAMAGE OR OVERLOAD THE EXISTING STRUCTURE. LIMIT CONSTRUCTION LOADING (INCLUDING DEMOLITION DEBRIS) ON EXISTING FLOOR SYSTEMS TO 40 PSF. 22. EXISTING REINFORCING SHALL BE SAVED WHERE AND AS NOTED ON THE PLANS. SAW CUTTING, IF AND WHERE USED, SHALL NOT CUT EXISTING REINFORCING THAT IS TO BE SAVED. A. ALL NEW OPENINGS THROUGH SLABS SHALL BE ACCOMPLISHED BY SAW CUTTING WHEREVER POSSIBLE. B. CONTRACTOR SHALL VERIFY ALL EXISTING CONDITIONS AND LOCATION OF MEMBERS PRIOR TO CUTTING ANY OPENINGS. C. WHERE NEW REINFORCING TERMINATES AT EXISTING CONCRETE, DOWELS EPDXY GROUTED INTO EXISTING CONCRETE SHALL BE PROVIDED TO MATCH HORIZONTAL REINFORCING, UNLESS OTHERWISE NOTED ON PLANS. TUKWILA BEST WESTERN PORTE' COCHERE GENERAL STRUCTURAL NOTES 25. CONTRACTOR SHALL CHECK FOR DRYROT AT ALL AREAS OF NEW WORK. ALL ROT SHALL BE REMOVED AND DAMAGED MEMBERS SHALL BE REPLACED OR REPAIRED AS DIRECTED BY THE STRUCTURAL ENGINEER OR ARCHITECT. CONCRETE 26B. CONCRETE SHALL BE MIXED, PROPORTIONED, CONVEYED AND PLACED IN ACCORDANCE WITH IBC SECTION 1905, 1906 AND ACI 301, INCLUDING TESTING PROCEDURES. CONCRETE SHALL ATTAIN A 28 -DAY STRENGTH OF f'c = 2,500 PSI AND MIX SHALL CONTAIN NOT LESS THAN 5 -1/2 SACKS OF CEMENT PER CUBIC YARD AND SHALL BE PROPORTIONED TO PRODUCE A SLUMP OF 5" OR LESS. ALL CONCRETE WITH SURFACES EXPOSED TO STANDING WATER SHALL BE AIR - ENTRAINED WITH AN AIR - ENTRAINING AGENT CONFORMING TO ASTM C260, C494, and C618. TOTAL AIR CONTENT FOR FROST - RESISTANT CONCRETE SHALL BE IN ACCORDANCE WITH TABLE 1904.2.1 OF THE INTERNATIONAL BUILDING CODE. 29. REINFORCING STEEL SHALL CONFORM TO ASTM A615 (INCLUDING SUPPLEMENT S1), GRADE 60, fy = 60,000 PSI. WELDED WIRE FABRIC SHALL CONFORM TO ASTM A -185. 32B. DETAILING OF REINFORCING STEEL (INCLUDING HOOKS AND BENDS) SHALL BE IN ACCORDANCE WITH ACI 315 -92 AND 318 -02. LAP ALL REINFORCEMENTS IN ACCORDANCE WITH "THE REINFORCING SPLICE AND DEVELOPMENT LENGTH SCHEDULE." PROVIDE CORNER BARS AT ALL WALL AND FOOTING INTERSECTIONS. LAP ADJACENT MATS OF WELDED WIRE FABRIC A MINIMUM OF 8" AT SIDES AND ENDS. NO BARS PARTIALLY EMBEDDED IN HARDENED CONCRETE SHALL BE FIELD BENT UNLESS SPECIFICALLY SO DETAILED OR APPROVED BY THE STRUCTURAL ENGINEER. 33. CONCRETE PROTECTION (COVER) FOR REINFORCING STEEL SHALL BE AS FOLLOWS' FOOTINGS AND OTHER UNFORMED SURFACES CAST AGAINST AND PERMANENTLY EXPOSED TO EARTH 3" FORMED SURFACES EXPOSED TO EARTH OR WEATHER ( #6 BARS OR LARGER) 2" FORMED SURFACES EXPOSED TO EARTH OR WEATHER ( #5 BARS OR SMALLER) . . 1 -1/2" COLUMN TIES OR SPIRALS AND BEAM STIRRUPS 1 -1/2" SLABS AND WALLS (INT. FACE). . . .GREATER OF BAR DIAMETER PLUS 1/8" OR 3/4" 34. CONCRETE WALL REINFORCING -- PROVIDE THE FOLLOWING UNLESS DETAILED OTHERWISE: 6" WALLS 8" WALLS 10" WALLS 12" WALLS #4 @ 16 HORIZ. #4 @ 12 HORIZ. #4 @ 18 HORIZ. #4 @ 16 HORIZ. #4 @ 18 VERTICAL 1 CURTAIN #4 @ 18 VERTICAL 1 CURTAIN #4 @ 18 VERTICAL 2 CURTAINS #4 @ 18 VERTICAL 2 CURTAINS 35. CAST -IN -PLACE CONCRETE: SEE ARCHITECTURAL DRAWINGS FOR EXACT LOCATIONS AND DIMENSIONS OF DOOR AND WINDOW OPENINGS IN ALL CONCRETE WALLS. SEE ARCHITECTURAL DRAWINGS FOR ALL GROOVES, NOTCHES, CHAMFERS, FEATURE STRIPS, COLOR, TEXTURE, AND OTHER FINISH DETAILS AT ALL EXPOSED CONCRETE SURFACES. TUKWILA BEST WESTERN PORTE' COCHERE GENERAL STRUCTURAL NOTES 38. NON - SHRINK GROUT SHALL BE FURNISHED BY AN APPROVED MANUFACTURER AND SHALL BE MIXED AND PLACED IN STRICT ACCORDANCE WITH THE MANUFACTURER'S PUBLISHED RECOMMENDATIONS. GROUT STRENGTH SHALL BE AT LEAST EQUAL TO THE MATERIAL ON WHICH IT IS PLACED (3000 PSI MINIMUM). ANCHORAGE 42B. EXPANSION BOLTS INTO CONCRETE AND CONCRETE MASONRY UNITS SHALL BE WEDGE -ALL ANCHORS AS MANUFACTURED BY THE SIMPSON STRONG TIE COMPANY AND INSTALLED IN STRICT CONFORMANCE TO ICBO -ES REPORT NUMBER ER -3631, INCLUDING MINIMUM EMBEDMENT REQUIREMENTS. BOLTS INTO CONCRETE MASONRY OR BRICK MASONRY UNITS SHALL BE INTO FULLY GROUTED CELLS. SPECIAL INSPECTION IS REQUIRED FOR ALL EXPANSION BOLT INSTALLATION. 43B. EPDXY - GROUTED ITEMS (THREADED RODS OR REINFORCING BAR) SPECIFIED ON THE DRAWINGS SHALL BE INSTALLED USING "SET" HIGH STRENGTH EPDXY AS MANUFACTURED BY THE SIMPSON STRONG TIE COMPANY. INSTALL IN STRICT ACCORDANCE WITH ICBO -ES REPORT NO. ER -5279. SPECIAL INSPECTION OF INSTALLATION IS REQUIRED. RODS SHALL BE ASTM A -36 UNLESS OTHERWISE NOTED. STEEL 54. STRUCTURAL STEEL DESIGN, FABRICATION, AND ERECTION SHALL BE BASED ON: 1. EITHER AISC -LRFD, AISC 355, OR AISC -HSS AND SECTION 2205.2 OF THE INTERNATIONAL BUILDING CODE. 2. MARCH 7, 2000 AISC CODE OF STANDARD PRACTICE FOR STEEL BUILDINGS AND BRIDGES, AMENDED AS NOTED IN THE CONTRACT DOCUMENTS AND BY THE DELETION OF PARAGRAPH 4.4.1. 3. SPECIFICATION FOR STRUCTURAL JOINTS USING ASTM A325 OR A490 BOLTS. 55B. ROLLED SHAPES INCLUDING PLATES, SHALL CONFORM TO ASTM A36, Fy = 36 KSI. STEEL PIPE SHALL CONFORM TO ASTM A -53, TYPE E OR S, GRADE 8, Fy = 35 KSI. STRUCTURAL TUBING SHALL CONFORM TO ASTM A500, GRADE B, Fy = 46 KSI. CONNECTION BOLTS SHALL CONFORM TO ASTM A307. 58. ALL ANCHORS EMBEDDED IN MASONRY OR CONCRETE SHALL BE A307 HEADED BOLTS OR A36 THREADED ROD WITH AN ASTM 563 HEAVY HEX NUT TACK WELDED ON THE EMBEDDED END. TUKWILA BEST WESTERN PORTE' COCHERE GENERAL STRUCTURAL NOTES 60. ALL WELDING SHALL BE IN CONFORMANCE WITH A.I.S.C. AND A.W.S. STANDARDS AND SHALL BE PERFORMED BY W.A.B.O. CERTIFIED WELDERS USING E70 XX ELECTRODES. ONLY PREQUALIFIED WELDS (AS DEFINED BY A.W.S.) SHALL BE USED. ALL COMPLETE JOINT PENETRATION GROOVE WELDS SHALL BE MADE WITH A FILLER MATERIAL THAT HAS A MINIMUM CVN TOUGHNESS OF 20 FT -LBS AT -20 DEGREES F AND 40 FT -LBS AT 70 DEGREES F, AS DETERMINED BY AWS CLASSIFICATION OR MANUFACTURER CERTIFICATION. WOOD 66. FRAMING LUMBER SHALL BE KILN DRIED OR MC -19, AND GRADED AND MARKED IN CONFORMANCE WITH W.C.L.B. STANDARD GRADING RULES FOR WEST COAST LUMBER NO. 17. FURNISH TO THE FOLLOWING MINIMUM STANDARDS: JOISTS (2X & 3X MEMBERS) HEM -FIR NO. 2 AND BEAMS: MINIMUM BASE VALUE, Fb = 850 PSI (4X MEMBERS) DOUGLAS FIR -LARCH NO. 1 MINIMUM BASE VALUE, Fb = 1000 PSI BEAMS: (INCL. 6X AND LARGER) DOUGLAS FIR -LARCH NO. 1 MINIMUM BASE VALUE, Fb = 1350 PSI POSTS: (4X MEMBERS) DOUGLAS FIR -LARCH NO. 2 MINIMUM BASE VALUE, Fc = 1350 PSI (6X AND LARGER) DOUGLAS FIR -LARCH NO. 1 MINIMUM BASE VALUE, Fc = 1000 PSI STUDS, PLATES & MISC. FRAMING: DOUGLAS- FIR -LARCH OR HEM -FIR NO. 2 67B. GLUE LAMINATED MEMBERS SHALL BE FABRICATED IN CONFORMANCE WITH ASTM AND AITC STANDARDS. EACH MEMBER SHALL BEAR AN A.I.T.C. IDENTIFICATION MARK AND SHALL BE ACCOMPANIED BY AN A.I.T.C. CERTIFICATE OF CONFORMANCE. ALL SIMPLE SPAN BEAMS SHALL BE DOUGLAS FIR COMBINATION 24F -V4, Fb = 2,400 PSI, Fv = 240 PSI. ALL CANTILEVERED BEAMS SHALL BE DOUGLAS FIR COMBINATION 24F -V8, Fb = 2400 PSI, Fv = 240 PSI. CAMBER ALL SIMPLE SPAN GLULAM BEAMS TO 3,000' RADIUS, UNLESS SHOWN OTHERWISE ON THE PLANS. 72. PLYWOOD SHEATHING SHALL BE GRADE C -D, EXTERIOR GLUE OR STRUCTURAL II, EXTERIOR GLUE IN CONFORMANCE WITH DOC PS 1. ORIENTED STRAND BOARD OF EQUIVALENT THICKNESS, EXPOSURE RATING AND PANEL INDEX MAY BE USED IN LIEU OF PLYWOOD. ROOF SHEATHING SHALL BE 1/2" (NOMINAL) WITH SPAN RATING 32/16. WALL SHEATHING SHALL BE 1/2" (NOMINAL) WITH SPAN RATING 24/0. REFER TO WOOD FRAMING NOTES BELOW FOR TYPICAL NAILING REQUIREMENTS. 74. ALL WOOD IN DIRECT CONTACT WITH CONCRETE OR MASONRY SHALL BE PRESSURE - TREATED WITH AN APPROVED PRESERVATIVE OR (2) LAYERS OF ASPHALT IMPREGNATED BUILDING PAPER SHALL BE PROVIDED BETWEEN UNTREATED WOOD AND CONCRETE OR MASONRY. 75. PRESSURE TREATED WOOD SHALL BE TREATED PER AWPA STANDARD C2 FOR LUMBER OR C9 FOR PLYWOOD. WOOD IN CONTINUOUS CONTACT WITH FRESH WATER OR SOIL SHALL BE TREATED TO A RETENTION OF 0.40 PCF. PRESSURE TREATED WOOD FOR ABOVE GROUND USE SHALL BE TREATED TO A RENTION OF 0.25 PCF. SODIUM BORATE (SBX) TREATED WOOD SHALL NOT BE USED WHERE EXPOSED TO WEATHER. FASTENERS AND TIMBER CONNECTORS IN DIRECT CONTACT WITH ACQ -A, CBA -A, CA -B, OR SBX TREATED WOOD SHALL BE G185 OR A185 HOT DIPPED OR CONTINUOUS HOT- GALVANIZED PER ASTM A653. FASTENERS AND TIMBER CONNECTORS IN DIRECT CONTACT WITH ACZA TREATED WOOD SHALL BE TYPE 304 OR 316 STAINLESS STEEL. 76. TIMBER CONNECTORS CALLED OUT BY LETTERS AND NUMBERS SHALL BE "STRONG -TIE" BY SIMPSON COMPANY, AS SPECIFIED IN THEIR CATALOG NUMBER C -2006. EQUIVALENT DEVICES BY OTHER MANUFACTURERS MAY BE SUBSTITUTED, PROVIDED THEY HAVE ICC -ES APPROVAL FOR EQUAL OR GREATER LOAD CAPACITIES. PROVIDE NUMBER AND SIZE OF FASTENERS AS SPECIFIED BY MANUFACTURER. CONNECTORS SHALL BE INSTALLED IN ACCORDANCE WITH THE MANUFACTURER'S RECOMMENDATIONS. ALL 2X JOISTS SHALL BE CONNECTED TO FLUSH BEAMS WITH "LUS" SERIES JOIST HANGERS. ALL TJI JOISTS SHALL BE CONNECTED TO FLUSH BEAMS WITH "ITT" SERIES JOIST HANGERS. ALL DOUBLE -JOIST BEAMS SHALL BE CONNECTED TO FLUSH BEAMS WITH "MIT" SERIES JOIST HANGERS. WHERE CONNECTOR STRAPS CONNECT BOLTS IN EACH MEMBER. ALL SHIMS SHALL BE SEASONED AS MEMBERS CONNECTED. 77. WOOD FASTENERS SIZE 8d 16d BOX TUKWILA BEST WESTERN PORTE' COCHERE GENERAL STRUCTURAL NOTES LENGTH 2 -1/2" 3 -1/2" TWO MEMBERS, PLACE ONE -HALF OF THE NAILS OR AND DRIED AND THE SAME GRADE (MINIMUM) A. NAIL SIZES SPECIFIED ON DRAWINGS ARE BASED ON THE FOLLOWING SPECIFICATIONS: DIAMETER 0.131" 0.131" IF CONTRACTOR PROPOSES THE USE OF ALTERNATE NAILS, THEY SHALL SUBMIT NAIL SPECIFICATIONS TO THE STRUCTURAL ENGINEER (PRIOR TO CONSTRUCTION) FOR REVIEW AND APPROVAL. NAILS - PLYWOOD (APA RATED SHEATHING) FASTENERS TO FRAMING SHALL BE DRIVEN FLUSH TO FACE OF SHEATHING WITH NO COUNTERSINKING PERMITTED. B. ALL BOLTS IN WOOD MEMBERS SHALL CONFORM TO ASTM A307. PROVIDE WASHERS UNDER THE HEADS AND NUTS OF ALL BOLTS AND LAG BOLTS BEARING ON WOOD. INSTALLATION OF LAG BOLTS SHALL CONFORM TO THE NATIONAL DESIGN SPECIFICATION FOR WOOD CONSTRUCTION (2001 EDITION) WITH A LEAD BORE HOLE OF 60 TO 70 PERCENT OF THE SHANK DIAMETER. LEAD HOLES ARE NOT REQUIRED FOR 3/8" AND SMALLER LAG SCREWS. 06-04 -2007 SOOZEE KIM 16212 BOTHELL EVERETT HY, F271 MILL CREEK WA 98012 RE: Permit No. D06 -369 15901 WEST VALLEY HY TUKW Dear Permit Holder: In reviewing our current records the above noted permit has not received a final inspection by the City of Tukwila Building Division. Per the International Building Code and/or the International Mechanical Code, every permit issued by the Building Division under the provisions of this code shall expire by limitation and become null and void if the building or work authorized by such permit is not commenced within 180 days from the date of such permit, or if the building or work authorized by such permit is suspended or abandoned at any time after the work is commenced for a period of 180 days. Based on the above, you are hereby advised to: Call the City of Tukwila Inspection Request Line at 206 - 431 -2451 to schedule for the next or final inspection. This inspection is intended to determine if substantial work has been accomplished since issuance of the permit or last inspection; or if the project should be considered abandoned. If such determination is made, the Building Code does allow the Building Official to approve one or more ex tensions of time for additional periods not exceeding 90 days each. Extension requests must be In wrllinr and provide satisfactory reasons why circumstances beyond the applicants control have prevented action from being taken. In the event you do not call for the above inspection and receive an extension prior to 07/16/2007 , your permit will become null and void and any further work on the project will require a new permit and associated fees. Thank you for your cooperation in this matter. Sincerely, J2adifer Marshall, Permit Technician xc: Permit File No. D06 -369 City of Tukwila Steven M. Mullet, Mayor Department of Community Development Steve Lancaster, Director 6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone: 206-431-3670 • Fax 206- 431 -3665 ACTIVITY NUMBER: D06 -369 DATE: 10 -03 -06 PROJECT NAME: BEST WESTERN SITE ADDRESS: 15901 WEST VALLY HY X Original Plan Submittal Response to Correction Letter # Response to Incomplete Letter # Revision # After Permit Issued DEPARTMENTS: Build g Did No li W ►M NAB, 4 A){0 DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete Comments: APPROVALS OR CORRECTIONS: Approved ❑ Notation: REVIEWER'S INITIALS: Documentshouting slip.doc 2 -28-02 PERMIT COORD COPY PLAN REVIEW /ROUTING SLIP Eli, 4 1A, 117 6'OU Fire Prevention Structural Incomplete ❑ TUES/THURS ROU ING: Please Route Structural Review Required REVIEWER'S INITIALS: Approved with Conditions go 10- Panning ivlsion Permit Coordinator ❑ DUE DATE: 10-05-06 Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: No further Review Required DATE: Not Applicable ❑ DUE DATE: 11-02-06 Not Approved (attach comments) ❑ DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: License Information License DELTAWL941BR Licensee Name DELTA WORLD LLC Licensee Type CONSTRUCTION CONTRACTOR UBI 602562168 Ind. Ins. Account Id 10137401 Business Type LIMITED LIABILITY COMPANY Address 1 16212 BOTHELL EVERETT HWY Address 2 F 271 City MILL CREEK County SNOHOMISH State WA Zip 98012 Phone 4258350002 Status ACTIVE Specialty 1 GENERAL Specialty 2 UNUSED Effective Date 2/28/2006 Expiration Date 2/28/2008 Suspend Date Separation Date Parent Company Previous License Next License DELTACG960CS Associated License Business Owner Information Name Role Effective Date Expiration Date KIM, SOOZEE PARTNER/MEMBER 02/28/2006 Look Up a Contractor, Electrician or Plumber License Detail Page 1 of 2 Washington State Department of Labor and Industries General/Specialty Contractor A business registered as a construction contractor with L&I to perform construction work within the scope of its specialty. A General or Specialty construction Contractor must maintain a surety bond or assignment of account and carry general liability insurance. Bond Information Bond # 2 Bond Company Name PLATTE RIVER INS CO Bond Account Number 41079028 Effective Date 08/15/2006 Expiration Date Until Cancelled Cancel Date Impaired Date Bond Amount $12,000.00 Received Date 08/17/2006 ACCREDITED https : / /fortress.wa.gov/lni/bbip/ printer .aspx7License= DELTAWL941BR 10/18/2006 x x x x x x x x x x x x x x x x x