HomeMy WebLinkAboutPermit D06-387 - Southcenter Square - Building N - SlabSOUTHCENTER SQUARE N BUILDING 17200 SOUTHCENTER PY D06 -387 City of Tukwila Parcel No.: 2623049081 Address: 17200 SOUTHCENTER PY TURW Suite No: Tenant: Name: SOUTHCENTER SQUARE - BLDG N Address: 17200 SOUTHCENTER PY, TUXWWILA WA Owner: Name: WIG PROPERTIES LLC -SS Address: 4811 134 PL SE , BELLEVUE WA 98006 Phone: Contact Person: Name: LESITYA WIG Address: 4811 134 PL SE , BELLEVUE WA 98006 Phone: 425 - 957 -4774 DESCRIPTION OF WORK: POUR SLAB ONLY FOR BUILDING 'N. Value of Construction: Type of Fire Protection: Type of Construction: Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us Contractor: Name: WIG PROPERTIES LLC -SS Address: 4811 134Th PL SE , BELLEVUE WA 98006 Phone: (425)641 -2044 Contractor License No: WIGPRPL945N3 $90,000.00 DEVELOPMENT PERMIT Fees Collected: $1,894.05 International Building Code Edition: 2003 Occupancy per IBC: 0019 * *continued on next page ** Permit Number: D06 - 387 Issue Date: 10/27/2006 Permit Expires On: 04/25/2007 Expiration Date: Steven M. Mullet, Mayor Steve Lancaster, Director doc: IBC-10 /06 006 -387 Printed: 10 - 2006 Public Works Activities: Channelization / Striping: N Curb Cut / Access / Sidewallc / CSS: N City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 -431 -3665 Web site: http: //www.ci.tukwila.wa.us Fire Loop Hydrant: N Number: 0 Size (Inches): 0 Flood Control Zone: Hauling: N Start Time: End lime: Land Altering: Volumes: Cut 0 c.y. Fill 0 c.y. Landscape Irrigation: Moving Oversize Load: Start Time: End Time: Sanitary Side Sewer: Sewer Main Extension: Private: Public: Storm Drainage: Street Use: Profit: N Non - Profit: N Water Main Extension: Private: Public: Water Meter: N Permit Center Authorized Signature: I hereby certify that I have read and governing this work will be compile Signature: Permit Number: DO6 -387 Issue Date: 10/27/2006 Permit Expires On: 04/25/2007 Date: (0124 40te permit and know the same to be true and correct. All provisions of law and ordinances , w1 tier specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the perfoynance of work. I am authorized to sign and obtain this development permit. Date: 117 / 2 R - /t Steven M. Mullet, Mayor Steve Lancaster, Director Print Name: /ACS' q w ` — 1 This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. dm: IBC-10/06 D06 -387 Printed: 10 -27 -2006 Parcel No.: 2623049081 Address: Suite No: Tenant: City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 - 431 -3665 Web site: httn: / /www.ci.tukwila.wa.us 17200 SOUTHCENTER PY TUHW SOUTHCENTER SQUARE -BLDG N 1: ** *BUILDING DEPARTMENT CONDITIONS * ** PERMIT CONDITIONS Permit Number: Status: Applied Date: Issue Date: D06 -387 ISSUED 10/13/2006 10/27/2006 2: No changes shag be made to the approved plans unless approved by the design professional in responsible charge and the Building Official. 3: All permits, inspection records, and approved plans shall be at the job site and available to the inspectors prior to start of any construction. These documents shall be maintained and made available until final inspection approval is granted. 4: The special inspections and verifications for concrete construction shall be required. 5: The special inspections for steel elements of buildings and structures shall be required. All welding shall be done by a Washington Association of Building Official Certified welder. 6: When special inspection is required, either the owner or the registered design professional in responsible charge, shall employ a special inspection agency and notify the Building Official of the appointment prior to the first building inspection. The special inspector shall furnish inspection reports to the Building Official in a timely manner. 7: A final report documenting required special inspections and correction of any discrepancies noted in the inspections shall be submitted to the Building Official. The fatal inspection report shall be prepared by the approved special inspection agency and shall be submitted to the Building Official prior to and as a condition of final inspection approval. 8: All construction shall be done in conformance with the approved plans and the requirements of the International Building Code or International Residential Code, International Mechanical Code, Washington State Energy Code. 9: Notify the City of Tukwila Building Division prior to placing any concrete. This procedure is in addition to any requirements for special inspection. - - 10: All wood to remain in placed concrete shall be treated wood. 11: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. doc: Cond -10/06 * *continued on neat page ** D06 -387 Printed: 10 -27 -2006 Signature: Print Name: / itk '^_2 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila,wa.us I hereby certify that I have read these conditions and will comply with them as outlined. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provision of any other work or local laws regulating construction or the performance of work. Date: ! L'/' 4-/ot doc: Cond -10/06 D06 -387 Printed: 10-27 -2006 CITY OF MIMIC Community Developftwolt Department Public Works Department Permit Center 8300 SoufreenterBlvd, Suite 100 Tukwila, WA 98188 f)tto : /Mwss d.lukwfa.wa.us Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax **Please Print" SITE LOCATION I Site Address: 17200 Southcenter Parkway Tenant Name N/A Pmperty Chita' Name; Wig Properties, LLC Mailing Address: 4811 134th" Plate SE CONTACT PERSON I Name: Leshya Wig Mailing Address: 4811 I34thiPlada SE E-Mail Address: Leshvawig@wigproperties.com I GENERAL CONTRACTOR INFORMATION — (Contractor Information for M«banical (pg 4) for Plumbing and Ca Piping (pg 6)) I Company Nant Unknown Mailing Address: Contact Person: E-Mail Address: Contractor Registration Number: I ARCHITECT OF RECORD — plans must be wet stamped by Architect efRecord I CompenyName: Freiheit& Bo Architects, Inc. P.S. Melling Address; 10230 NE Points Drive, #300 Contact Person: Arthur Chang E- Mail . AChangefhoarch. coo I ENGINEER OF RECORD — All plans must be wet stamped by Engineer if taco i'd CompaayName: Bush. Roed & Bitchings, MatlingAddress: 2009 Minor Avenue East ContactPersoa: Jav Decker. PE E•MailAddresa: faytlfdh ¢Weies++ramanac+ontbat a•P aanw+++ Mtn* sun a Ire. Building Pen flgo. (7n(D- Mechanical Permit No. Plumbing/Gas Permit No. Public Works P7 h 1tt0 No. Project No. (Fo use of King Co Assessor's TaxNo.:, 962104 -9080. —90A 1. —9117 Suite Number. Floor New Tenant: ❑...„Yes Bellevue Civf Seattle car Day Telephone: Fax Number, WA see. ❑S 98006 ye • Day Telephone: 47C-057-4774 Bellevue WA 98006 ow awe r Fax Number: 425 - 865 -8648 c a rer r Day Telephone: Fax Number: Expiration Date: Kirkland WA 98033 ow are nr Day Telephone. 425 827 - 2100 Fax Number: 425 -828 -6899 WA 98102 Sea r+r 206 - 323 -4144 206 -323 -7135 Page 1ef6 Tra Valuation of Project (contractor's bid price): S Ro • 00(2 Existing Building Valuation: S / Scope of Work (please provide detailed ihforniation) :. - e n DT (le;c. Will there be new rack storage? ❑ ..Yes [].. No . (If yes, a separate permit and plan submittal will be required) PLANNING DIVISION: Single - family building footprint (area of the foundation of all anuaures, plus any decks ova II Indies and overhangs greater than III kwfies *For an Accessory dwelling, provide the following: . Lot Area (sq ft): . Floor area of principal dwelling: Floor area for accessory dwelling: *Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard: Compact: Handicap: Will there be a change in use? ❑ ....Yes ❑ ..No If "yes ", explain: FIRE PROTECTION/HAZARDOUS MATERIALS: ❑..Sprinklers ❑ -Automatic Fire Alarm ❑ O: Other (specify) Will there be storage or use of flammable, combustible or hazardous materials in the building? ❑..Yes ❑..No If "yes", attach list of materials and storage locations on a separate 8-1/2 s /J paper Indicating quantities and Material Safety Data Sheets. SEPTIC SYSTEM: ❑ On -site Septic System — For on -site septic system, provide 2 copies of a current septic design approved by King County Health Department. o:Wotw ff saas-Applicaasas On u„.134006- rasa Applicatialae Reeked: 4 -2006 M Page 2 of 6 88/23/2006 14 :26 4250650648 9s9o SEATAC DEUELE'hENT PAGE 02/02 w lottat «s_aWreS4.swwrseomorewaSIPnte •.tatxzisnil.tt03A1davo anclic einv VW 1catrw3smmlPYMaoazvas Hl a0SIAY7 WAVE= SIASIVX341 win aim se: O1 37[YPBFu & CI 0IWNO ItV0nd4YBffi1Q9NI IIMfdOrtYCY+IM Urn iSVaL sto AIU!RI * Nn. Minn) °P°, SWIM mu mon TaAOaa°anP Dario olga$Baafpp Papal al Fasorbos°quns :opus ogl• aa9a ..paper ptiog59taxi°apy99o(um * amaidA9PP1V0 'SIM Kt •( m! np Swap) WO t? cannaepwu..,4Pla Sunni Tarim heitp4 cops ma ice sap ofl J cepa mows xisappioogwres'aw oungs.4SntePBb!nnn8at1. SIGEBTFWEETWITWEVIPIT vermin gultbs Int 10 3aaPP°g► 00 gePPA Virg r" airs units swift vorreps Pal 14Pa9 Pains►+° 9ILL Swell km estimatk°gtA47s>epsaalp7 i amvimins3* '$fi s°Pa , a+4sA • . Receipt No,: R06 -01730 Initials: JEM User ID: 1165 Payee: WIG PROPERTIES, LLC -SS Payment Check 1461 ACCOUNT ITEM LIST: Description doc: Receipt -06 BUILDING - NONRES STATE BUILDING SURCHARGE City of Tukwila Parcel No.: 2623049081 Address: 17200 SOUTHCENTER PT TUICW Suite No: Applicant: SOUTHCENTER SQUARE - BLDG N Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.cttukwila.wa.us RECEIPT TRANSACTION LIST: Type Method Description Amount 1,149.68 Account Code Current Pmts 000/322.100 1,145.18 000/386.904 4.50 Total: $1,149.68 Permit Number: D06 -387 Status: APPROVED Applied Date: 10/13/2006 Issue Date: Payment Amount: $1,149.68 Payment Date: 10/27/2006 02:38 PM Balance: $0.00 1207 10/27 9716 TOTAL lf4Sd3 10 -27 -2006 City of Tukwila 6300 Southcenter BL, Suite 100 / Tukwila, WA 98188 / (206) 431 -3670 Parcel No.: 2623049081 Permit Number: D06 -387 Address: 17200 SOUTHCENTER PY TUKW Status: PENDING Suite No: Applied Date: 10/13/2006 Applicant: SOUTHCENTER SQUARE - BLDG N Issue Date: Receipt No.: R06 -01638 Payment Amount: 744.37 Initials: BLH Payment Date: 10/13/2006 03:31 PM User ID: ADMIN Balance: $1,149.68 Payee: WIG PROPERTIES LLC TRANSACTION LIST: Type Method Description Amount Payment Check 1449 744.37 ACCOUNT ITEM LIST: Description Current Prate PLAN CHECK - NONRES RECEIPT Account Code 000/345.830 744.37 Total: 744.37 0796 10/16 9710 TOTAL 744.37 doc: Receipt Printed: 10 -13 -2006 Project: /�y�Tpype fir / W C of Inspec on: y v Ad ress: 1 1 ?r) iSO a.- 1-4--t/ Date Called: Special Instructions: / Date Wanted. 777:17 pm, Requester: Phone No: 2 -- INSPECTION NO. INSPECTION RECORD Retain a copy with permit PERMI / CITY OF TUKWILA BUILDING DIVISION it 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 {36 (Date, 0 $513. INSPECTION P REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call the schedule reinspection. a pproved per applicable codes. Ei Corrections required prior to approval. COMMENTS: 61 79 P/At � � 44 7 'Receipt No.: 'Date: Pr ( g � e _ cf: ,�J 7.t al L, Mi, (' tie 7Q ! i ' r c r� g of Inspection: . 7az /AJ Called: / . / c-117,/. Address: k / 72 A9 Special Instructions: DAtE Wanted: / y �--y // — -?--Cg la m P.m. Requester: Phone No: INSPECTION RECORD /yy Retain a copy with permit y..�-3g INSPECTION NO. PERMIT N CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206) 3670 Approved per applicable codes. COMMENTS: PA i• v -P✓ /N� - /i /%9/H 40 4- A a )'eI Inspector; Date: // 7_0/ $58.00 REIySPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 63 Southcenter Blvd., Suite 100. Call to sechedute reinspection. Receipt No.: Date: Corrections required prior to approval. 09/11/2007 15:16 2067232221 OTTO ROSENAU & ASSOCIATES, INC. August 15, 2007 City of Tukwila Building Department 6200 Southcenter Boulevard Tukwila, Washington 98188 OTTO ROSENAU PAGE 01/02 Sincerely, OTTO ROSENAU & ASSOCIATES, INC. .31,00an &Denali - nWed- Susan Rosenau -Moser Vice President GeotechnIcat Engineering, Cored/Wien Inspection & Materials Testing 6747 M. L King Way South, Seattle, Washington 98118.3218 USA Tel: (206) 725-4600 • Toll Free: (888) OTTO-4-US • Fax (209) 723 WUE w2F6913684 • WABO RegIsteed Agency • %bade: www.cacrosenau.com Project: Southcenter Square Building N Permit Number(s): 1)06 008 - 457 Address: 17200 Southcenter Parkway, Tukwila Job Number. 06 -683 We state that the work requiring special inspection was, to the best of our knowledge, in conformance with the approved plans and specifications and the applicable workmanship provision of the building code. Our knowledge Is limited to our reports. All typewritten reports have been mailed to your office or are enclosed. All reports appear to be complete. This report should not be considered as a warranty for conditions and/or details of the building. Items inspected are: 1. Reinforcing steel 2. Reinforced concrete 3. Reinforced masonry 4. Structural steel erection to include welding and high strength bolts 5. Epoxy grouting 6. Anchor bolt installation 7. Lateral framing 8. Grout under panels/columns Email a Wig Properties Attn: Mike Weflen GEOTECH CONSULTANTS, INC. Wig Properties 4811 — 134th Place Southeast Bellevue, Washington 98006 Attention: M.K. Wig Subject: Summary of Geotechnical Observations and Testing During Building Pad Preparation North Building (Permit Nos. D06 -387 and D06 -457), South Building (Permit Nos. D06 -351 and D06 -416) and East Building (Permit Nos. D06 -377 and D06 -384) Southcenter Square 17200 Southcenter Parkway Tukwila, Washington Dear Mr. Wig via email monwig @wigproperties.com This letter summarizes the geotechnical observations and testing that our firm completed during the preparation of the foundation and slab subgrades for these three buildings on the Southcenter Square project. Our personnel observed the excavation for the subgrade areas, and placement and compaction of structural fill, in addition to conducting density tests on the structural fill. In accordance with the recommendations of our previous geotechnical report, the foundations for the new buildings were supported on at least 2 feet of structural fill compacted to a minimum 95 percent of the maximum Modified Proctor (ASTM D -1557) dry density. The lower one foot of this structural fill consisted of on -site soils, while the upper one foot was compacted crushed concrete. The structural fill was compacted in lifts to a dense condition. Underlying the structural fill was the previously placed, well - compacted fill that covers the entire project site. Based on our observations, and density tests, the building pads for these two buildings were prepared in conformance with our recommendations and are acceptable for support of both foundations and floor slab cc: Mike Wefflen via facsimile (206) 575 -6680 � EXPIRES . d_ -. -. _. ___10125107 1 Respectfully submitted, GEOTECH CONSULTANTS, INC. 9 /S�� Marc R. McGinnis, P.E. Principal GEOTECH CONSULTANTS, INC. 13256 Northeast 20th Street, Suite 16 Bellevue, Washington 98005 (425) 747 -5618 FAX (425) 747 -8561 September 5, 2007 JN 04318 OTTO ROSENAU & ASSOCIATES, INC. Geotechnical Engineering, Construction Inspection & Materials Testing Report Number. 60879 Description: Lateral Framing and Structural Steel Erection CONSTRUCTION INSPECTION REPORT DOr. -387 Project Southcenter Square Permit Number. 096467_DfdgrN Address: 17200 Southcenter Parkway, Tukwila Job Number. A6 - 693. Client Wig Properties LLC - SS Client Address: 4811 134 Place SE, Bellevue Inspector and Date Remarks Isaac Ruoff Anived on site to inspect the welds on the C channel bracing for the angled walls on roof. Welds 4/23/2007 were made using theSMAW and performed by Christopher L. Mansfield WABO# W0724 with an expiration date of July 1, 2007. Welds were as per approved plans and AWS D1.1. Also while on site I inspected the pan deck at the angled roof walls. Pan decking was screwed as per approved plans and engineer RFI's. Conform Copies to: Owner X Contractor X Architect X Building Dept. Technical Responsibi X Engineer David Lyal, Technical Director This report applies only to the Items tested or reported and Is the exclusive property of Otto Rosenau & Associates, Inc. Reproduction of this report, except in full, without written permission from our firm Is strictly prohibited. Page 1 of 1 6747 M.L. King Way S., Seattle, Washington 98118 - Phone (206) 725 - 4800 or 1 888 OTTO - Fax (206) 723 - 2221 Form No.: ADMIN -63-01 (Rev 05(03) GIL /4 it zott YJG: J/ GEOTECH CONSULTANTS. INC. Wig Properties 4811 -134th Place Southeast Bellevue, Washington 98006 4LD /4 /WOW. ILtJ ICLCI Attention: M.K. Wig Subject: Foundation Drains Southcenter Square 17200 Southcenter Parkway Tukwila, Washington Dear Mr. Wig: via email We understand that the City of Tukwila is requesting a clarification regarding the potential need for footing drains around the proposed buildings. Per our Geotechnical Engineering Report dated June 20, 2006, Page 12: 'Foundation drains should be used where (1) crawl spaces or basements will be below the structure, (2) a slab is below the outside grade, or (3) the outside grade does not slope downward from a building. A drain on the outside of the foundation must be installed where there are truck wells to collect drainage flowing under the granular fill below the pavement. Drains should also be placed at the base of all earth - retaining Based on the above information, a footing drain should not be required around the perimeter at most, or all, locations, as we understand the finished floor slab elevations are above the surround- ing finished grades. If any questions, please contact me at (425) 7475618 +tspectfully submitted, GEOTECH CONSULTANTS, INC. MRM: jyb . Mare R. McGinnis, P.E. 'Age, Principal `. 10/2S/07 t GEOTECH CONSULTANTS, INC. 13256 Noz heat 20th Street, Suitt 16 Bellevue. Washington 98005 (425) 747 -5618 FAX (425) 747 -8561 February 26, 2007 JN 04318 1,79(0 31- iS: RECEWED FEB 2 7 20137 BUILDING DEPARTMENT RICHARD HUDSON & ASSOCIATES, INC. Rick Hudson, P.E. CONSULTING ENGINEERS Chuck Moms, P.E. 1605 12 AVENUE • SUITE 18 SEATTLE, WASHINGTON 98122 206 - 324 -6160 Par colt FAX 206 - 324 -6248 EMAIL: cmorris @hudsonengineers.com o%, • c1 mit No. Structural Calculptions For t Interior Foundation of Souti►center Square Bldg N Tukwila, WA =r1ae ;pt Code: I.B.C. 2003 Loads: Roof Snow (uniform) 25 PSF Foundation: Foundation designed per report Geotech Consultants, Inc. # JN04318. Allowable soil bearing 3000 PSF. This peat is for the interior pad footings and concrete slab on grade only. Calculations include the roof framing design for vertical load run down. The lateral system will be concrete shear walls at the exterior of the building and will not have an impact on the interior footing design. r REVIEWED FOR CODE COMPLIANCE f $ nnnn'/Cn OCT 2 6 2006 f(4& ICi/ City Of Tukwila BUILDING DIVISION RECEIVED CITY OFT(JKWILP OCT 13 ?OH PERMIT CENTER riAa (0 RICHARD HUDSON & ASSOCIATES, INC. CONSULTING ENGINEERS 1605 12TH AVENUE • SUITE 18 SEATTLE, WASHINGTON 98122 206 - 324 -6160 • Fax 206 - 324 -6248 rhudson@hudsonengineers.com JOB S ip j '4t110t Sant 11. SHEET NO. / OF ,A CALCULATED BY 611V1 • DATE /fi // 3 AC, 0 0 O 0 O O 0 O O 0 0 0 u ," r r 5 I4. w . J I S. 7 0. 14 S. r J ■. 1 Is .. 1 0 J A O 0 0 0 0 0 RICHARD HUDSON & ASSOCIATES, INC. J08 wit. `, )WC01-. _ CONSULTING ENGINEERS SHEET NO / OF 1605 12TH AVENUE • SUITE 18 SEATTLE, WASHINGTON 98122 CALCULATEDSV DATE /Oh 5 ,btu 206 - 324 -6160 • Fax 206 - 324 -6248 rhudson@hudsonengineers.com Ftc.i anc,oun,oU OnitytiK, Tw 6vr A=e-- Tara. F $ICE. Ana-, to ►e6 608 „.!. 2 tS . 3 941 1t 88/ 6 --} i231 /484 8 Itry zorgi to »et- it /: o -a-o l2 /.3a5 13 /9;1 44. 1120 15 /1. 2o 11. fig to tl /b to IS . . _ . , It 33 tq /1`y so /tor '. 444 �` o ) t- " 9! 2 r a ,s9 fir l- 4.">e 2 '/ @ � 4/44 ! 1j :514, �t � prate/milt leatztzeic *a cie 1sive 91 0 c Crte • 8 K c- obis) /z + �9t93 70 G " A5 ` c nitA �r *al 6- er g. 08 -30 -2007 LESHYA WIG 4811 134 PL SE BELLEVUE WA 98006 RE: Permit No. 006 -387 17200 SOUTHCENTER PY TUKW Dear Permit Holder: Thank you for your cooperation in this matter. Sincerely, ctutveuta Permit Technician xc: Permit File No. D06 -387 City of Tukwila Steven M. Mullet, Mayor Department of Community Development Steve Lancaster, Director In reviewing our current records the above noted pemrit has not received a final inspection by the City of Tukwila Building Division. Per the International Building Code and/or the International Mechanical Code, every permit issued by the Building Division under the provisions of this code shall expire by limitation and become null and void if the building or work authorized by such permit is not commenced within 180 days from the date of such permit, or if the building or work authorized by such permit is suspended or abandoned at any time after the work is commenced for a period of 180 days. Based on the above, you are hereby advised to: Call the City of Tukwila Inspection Request Line at 206431 -2451 to schedule for the next or final inspection. This inspection is intended to determine if substantial work has been accomplished since issuance of the permit or last inspection; or if the project should be considered abandoned. If such determination is made, the Building Code does allow the Building Official to approve one or more extensions of time for additional periods not exceeding 90 days each. Extension requests must be in writine and provide satisfactory reasons why circumstances beyond the applicants control have prevented action from being taken. In the event you do not call for the above inspection and receive an extension prior to 10/24/2007 , your permit will become null and void and any further work on the project will require a new permit and associated fees. 6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone: 206 -431 -3670 • Fax: 206- 431 -3665 April 27, 2007 Leshya Wig Wig Properties, LLC 4811 134 P1 SE Bellevue WA 98006 RE: Request for Extension Development Permit No. D06 -351, D06 -359 & D06 -387 Wig Properties —17200 Southcenter Py Dear Ms. Wig: This letter is in response to your written request for an extension to Permit Numbers D06 -351, D06 -359, and D06 -387. The Building Official has reviewed your letter and considered your request to extend the above referenced permits. The City of Tukwila Building Division will be extending the expiration date of D06 -351 and D06 -387 for an additional 180 days (through October 24, 2007). Permit D06 -359 is not being extended at this time since the discussion provided in your request did not apply to this permit. If you should have any questions, please contact our office at (206) 431 -3670. Sincerely, File: Permit No. 1)06 -351, 359, 387 City of Tukwila Department of Community Development Steve Lancaster, Director P:Vmmiter ztmsion LetteraTemeb12006\D06- 351, 359, 387 Permit Extemioadoe Page I of 1 in Steven M. Mullet, Mayor 6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone: 206 - 431 -3670 • Fax: 206-431-3665 4811 134 Place SE, Bellevue WA 98006 Tel: 425- 747 -8540, Fax: 425- 865 -8648 April 12, 2007 NA- dfo ^. RE: Permit Extension for D06 -351 D06 -359, 06- 387 " 17200 Southcenter Parkway Tukwila, WA Mr. Bob Benedicto City of Tukwila Dear Mr. Benedicto, We recently received three letters from the City of Tukwila notifying us that the above referenced permits will expire later this month. I am writing to request an extension for these permits. Although the north and south slabs were poured many months ago, the pour strips at the perimeter of these buildings were left open. Most of the pour strip area on the north and south slabs were then poured at the end of March. Our concrete inspector waits 28 days after their last pour before issuing their inspection report. My understanding is that this inspection report is required to call in a final inspection to the City. For your information, the pour strips on the east end of these buildings (where the sewer line goes in) on the north and south buildings will not be poured until the time of completing the individual tenant improvements. Please let me know if the City prefers that we complete the finals on the north and south slab as soon as we receive the inspection report or if the City would like us to wait until the entire pour strips have been completed. Thank you for your help on this matter! Sincerely Leshya Wig Wig Properties, LLC (425) 957-4774 Wig Properties, LLC aR 0. aGed otea ew f -oo6 361 �s1 OSfro flu awst DOG -307 3 - rin- ( 04-tl - 2 00 7 1 "Mi tea 04 -05 -2007 LESHYA WIG 4811 134 PL SE BELLEVUE WA 98006 RE: Permit No. D06 -387 17200 SOUTHCENTER PY TUKW Dear Permit Holder: Thank you for your cooperation in this matter. Sincerely, Ter Marshall, Permit Technician xc: Permit File No. D06.387 City of Tukwila Steven M. Mullet, Mayor Department of Community Development Steve Lancaster, Director In reviewing our current records the above noted permit has not received a final inspection by the City of Tukwila Building Division. Per the International Building Code and/or the International Mechanical Code, every permit issued by the Building Division under the provisions of this code shall expire by limitation and become null and void if the building or work authorized by such permit is not commenced within 180 days from the date of such permit, or if the building or work authorized by such permit is suspended or abandoned at any time after the work is commenced for a period of 180 days. Based on the above, you are hereby advised to: Call the City of Tukwila Inspection Request Line at 206431 -2451 to schedule for the next or final inspection. This inspection is intended to determine if substantial work has been accomplished since issuance of the permit or last inspection; or if the project should be considered abandoned. If such determination is made, the Building Code does allow the Building Official to approve one or more extensions of time for additional periods not exceeding 90 days each. Extension requests must be In writing and provide satisfactory reasons why circumstances beyond the applicants control have prevented action from being taken. In the event you do not call for the above inspection and receive an extension prior to 05/02/2007 , your permit will become null and void and any further work on the project will require a new permit and associated fees. 6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone: 206 431 - 3670 • Fax: 206 - 431 - 3665 ACTIVITY NUMBER: D06 -387 DATE: 10 -13 -06 PROJECT NAME: SOUTHCENTER SQUARE - BLDG N SITE ADDRESS: 17200 SOUTHCENTER PY X Original Plan Submittal Response to Incomplete Letter # Response to Correction Letter # Revision # After Permit Issued DEPARTMENTS: G ID " 6 51 nk la'► �e M) 41 0-0 �.. B d ng ivision Fire Prevention Planning Division `4 Pu Iic Morks F itfrito Structural ❑ Permit Coordinator U DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete [ Incomplete ❑ Comments: Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: TUES/THURS ROU ING: Please Route Structural Review Required REVIEWER'S INITIALS: Documents/cooling slip.doc 2-28-02 APPROVALS OR CORRECTIONS: PERMIT COORD COPY '' PLAN REVIEW /ROUTING SLIP DUE DATE: 10-1 7-06 Not Applicable ❑ No further Review Required DATE: DUE DATE: 11 -14 -06 Approved ❑ Approved with Conditions Not Approved (attach comments) ❑ Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: License Information License WIGPRPL945N3 Licensee Name WIG PROPERTIES LLC -SS Licensee Type CONSTRUCTION CONTRACTOR UBI 602392950 Ind. Ins. Account Id PARTNER/MEMBER Business Type LIMITED LIABILITY COMPANY Address 1 4811 134TH PL SE Address 2 City BELLEVUE County KING State WA Zip 98006 Phone 4256412044 Status ACTIVE Specialty 1 GENERAL Specialty 2 UNUSED Effective Date 8/23/2006 Expiration Date 8/23/2008 Suspend Date Separation Date Parent Company Previous License SEA TADC016JH Next License Associated License Business Owner Information Name Role Effective Date Expiration Date WIG, MANMOHAN K PARTNER/MEMBER 08/23/2006 WIG, PRISCILLA P PARTNER/MEMBER 08/23/2006 Look Up a Contractor, Electrician or Plumber License Detail Page 1 of 2 \ Washington State Department of Labor and Industries General/Specialty Contractor A business registered as a construction contractor with L&I to perform construction work within the scope of its specialty. A General or Specialty construction Contractor must maintain a surety bond or assignment of account and carry general liability insurance. Bond Information Bond Bond Company Name Bond Account Number Effective Date Expiration Date Cancel Date Impaired Date Bond Amount Received Date TRAVELERS https: // fortress .wa.gov /lni/bbip /printer.aspx ?License= WIGPRPL945N3 10/27/2006 x x x x