Loading...
HomeMy WebLinkAboutPermit 0109-M - Southcenter Mall - Squire ShopCITY OF TUKWILA (7 Building Division 6200 Southcenter Boulevard Tukwila, Washington 98188 (206) 433 -W* 18.4-9 BUILDING PERMIT f Work to be done HVAC Site Address 852 SOUTHCENTER MALL uite enant SQUIRE SHOP Building Use RETAIL Assessors Account # N/ Property Owner CENTER RIDGE CORP Phone N 246 -7400 Address 633 SOUTHCENTER MALL TIIKWIIA, WA Zip gRIRR Contractor CASCADE AIR CONDITIONING_ HASCAAC1g7C$ 1 Pho e # 784 -3135 Address 1544 N.W. BALLARD WAY S.EATIIiFI, WA (' () n TP 98107 PERMIT # D /d9 -"1 Control # 89 -005 -M /A1 FOR BUILDING PERMIT ONLY Approved for Issuance By: Sq. Ft. s`i`t FT. Office Storage/ Warehouse Retail Other Occ. Load Znd Fl. -3rd Fl. Total INV Fire Protection: [] Sprinklers [] Detectors Zoning Type of Construction Special Conditions w. J Fees Date:/-- sq. ft. @ 1st Fl. S sq. ft. @ 2nd Fl. $ sq. ft. @ other S sq. ft. (0 other $ Total Valuation of Construction S 12,500 Bldg. Permit Fee Plan Check Fee Demolition Surcharges Other Other TOTAL Receipt # 75g'/ S. 24.00 Receipt #75-(.3'4/ Receipt I S Receipt I S_ Receipt M S Receipt N S w - $ 30.00 FUR SIGN PERMIT ONLY ❑ Permanent [] Temporary ❑ Single Face [] Double Face [] Wall Mounted [] Free Standing ❑ Other Building face Setbacks: Front Side Side Rear Square Footage of each sign face Total square footage of sign Special Conditions THIS PERMII VECUMES NULL ANU VOID IF WORK OR CONSTRUCTION AUTHORIZED IS NOT COMMENCED WITHIN 180 DAYS, OR IF CONSTRUCTION OR MURK IS •,YEMJEO OR A8ANDONEU FUR A PERIOD OF 180 DAYS AT ANY TIME AFTER WORK 15 COMMENCED. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW Tad SAME TO RE TRUE AND CORRECT. ALL PROVISIONS OF LAWS ANU JuotssNCE5 GOVERNING THIS TYPE OF WORK WILL RE•COMPLIED WITH WHETHER SPECIFIED HEREIN DR NOT. THE GRANTING OF A PERMIT DOES NOT PRESUME TO GIvE To VIOLATE U*....CANCEL THE PROVISIONS OF ANY OTHER STATE OR LOCK LAW REGULATING CONSTRUCTION OR THE PERFORMANCE OF CONSTRUCTION. Signed Date / -V-Sr7 LICENSED CONTRACTORS DECLARATION I hereby affirm that I M ensed u der provisions of the lusiness and Professions Code, and •y license is in full force and effect. Contractor (signature) Date I.3 / —t t OWNER - BUILDER DECLARATION ( ) I. as owner of the property, or •y employees, with wages as their sole canonisation, will do the work, offered for sale. I ) I, as owner of the Owner (signature) and the structure Is ^n, - .'n?o or property. an exclusively Contracting with licensed contractor's to construct the project. Oats CITY OF TUKWILA Building Division 6200 Southcenter Boulevard Tukwila, Washington 98188 (206) 433 - 1541 BUILDING PERMIT Work to be done HVAC Site Address 852 SOUTHCENTER MALL Building Use RETAIL Property Owner CENTER RIDGE CORP Address 633 SOUTHCENTER MALL Contractor CASCADE AIR CONDITTONINr Address 1544 N.W. BAI LARIZ WAY PERMIT f G /6 -� Control 0 89 -005 -M Suite 0 Tenant SQUIRE SHOP Assessors Account li N/A Phone N 246 -7400 FUR BUILDING PERMIT ONLY Approved for TIIKWTI A, WA 4CASCAAf.197rR SEATTLE,-WA Issuance By: -1. %,. , Zip 9R1RR Phone 0 784 -3135 lip 48107 Date: / 7 Sq. Ft. Office Watrehous! Retail Other IOcc. Load 1st Fl. 2nd Fl. '3rd Fl. 1 14 • Total Fire Protection: ❑ Sprinklers ❑ Detectors Zoning Type df Construction Special Conditions Fees sq. ft. A sq. ft. e sq. ft. @ sq. ft. A Total Valuation of Construction S 12 500 Bldg. Permit Fee Receipt N 7,/v S 24.00 Plan Check Fee Receipt # 7 —s-om S � nn Demolition Receipt 0 S Surcharges Receipt N S Other Receipt N S Other Receipt N S 1st Fl. $ 2nd Fl. $ other $ other $ I TOTAL S 30.00 FUR SIGN PERMIT ONLY ❑ Permanent [] Temporary ❑ Single Face ❑ Double Face [I Wall Mounted ❑ Free Standing ❑ Other Building face Setbacks: Front Side Side Rear Square Footage of each sign face Total square footage of sign Special Conditions. THIS PERMIT BECOMES NULL AND VOID IF WORK 00 CONSTRUCTION AUTHORIZED IS NOT COMMENCED WITHIN 180 DAYS, OR IF CONSTRUCTION UR MURK IS . ;%(4)(0 OR ABANOONEU FUR A PERIOD OF 180 DAYS AT ANY TINE AFTER WORK IS COMMENCED. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KIM THE SAME TO K TRUE AND CORRECT. ALL PROVISIONS Of LAWS AhU JRONAhCES GOVERNING WORK WITH WHETHER SPECIFIED INA GRANTING WT NOT PRESUME U y 1,'40RITy TO VIOLATE CANCEL THE PROVISIONS OF ANY OTHER STATE IOC LLW RGULATINGCOTRUCTION ON THE PERFORMANCE OFC,,StauCTION. ' Signed Oat., / —c3/ 27 LICENSED CONTRACTORS DECLARATION I hereby affirm that I M ' ense/ uu der provisions of the 'witness and Professions Code, and sty license Is in full force and effect. Contractor (signature) �!dH Date i'—/—gel OWNER- BUILDER DECLARATION property, or ny employees, with wages as their sole compensation, rill do the work, and the structure property, M esClYttvely contracting with licensed contractor's to construct the project. Date ( ) 1, as owner of the offered for sale. ( ) I, as owner Of the Owner (signature) ,s n, , ;age Or d3U'. 9Sf' : IO11. i11fY1'iilSC.tlMllek�SOltklY+Pu� zGfo�.xw�.'cwanu+n.v+w..rr• aEY OF TUKWILA Building Division &2n0 Southcenter Boulevard' Tukwila, Washlnaton. 98188: (206) 433 -1849 ...,..............,,.,,,,,. ..........ww- r..w.wwwx.r +avxr.. INSPECTION RECORD PERMIT # Date Type of Inspectio Site Address 2 jam. Requestor -L ( la&Y Special Instructions to Wanted _ .3 Project Phone bye. 3:30 a.m. Inspection Results /Comments: Inspector. Date ...,...�..a,.«...... -... .-..-. �. ee. r. w_.- w,.......' w,.,..,.........,. ..«. .............. ......�. -..L. r.. w+ n• nw+. �., a. o. �naxlt+ etawiMAx� ,YRL'nlnikr3.CM'JiAK::: �,.I' TT OF TUKWILA Building Division A200 Southcsnter Boulevard Tukwila, Washington 98188 (206) 433 -1849 Type of Inspection. Site Address Requestor Special Instructions INSPECTION RECORD PERMIT # Date -elf' Date Wanted Project .9.47wi%*46 9 Phone # r 10. Inspection Results /Comments: ,,& a/ Inspector Date . THE FOLLOWING COMMENTS APPLY TO AND BECOME PART OF. THE APPROVED PLANS UNDER TUKWILA BUILDING PERMIT NUMBER O to 9 - M 1. No changes will be made to plans unless approved by Architect and Tukwila Building Department. • Electrical work to be inspected by State Electrical Inspectors and all required electrical permits obtained through that agency. • All permits to be posted at job site prior to start of any construction. ▪ Any exposed insulation backing material to have Flame Spread Rating of 25 or less. All construction to be done in conformance with approved plans and requirements of the Uniform Building Code (1985 Edition), Uniform. Mechanical Code (1985 Edition), Washington State Energy Code (1986 Edition), and Washington State Regulations for :Barrier Free Facility (1986 Edition). CITY OF TUKWILA Building Division 6200 southeenter Boulevard MECHANICAL PERMIT APPLICATION Tukwila, Washlnotnn amiss (206)- 433 -1849 ?5-2 Site Address 6007/ GENTLER /Y) CU..-(. Project Name /Tenant»SQL) I R&—. '/Y P Valuation of work /Z,, OO Property Owner eftetkei7 COY 0 . Address 69g6 501Anicenitai Appl i canteASCA DE /}(Q ccIUDiTioNIA1 . Address /54y N14-) BALLJ' RD LAY CONTROL# 0 Oo5 nl- e/A,YTgg Suite# Floor# Assessors Account # tAli /- Phone at-l(p -IL/00 Zip QM8 LpAt1L d LTV) Phone 7841—t?/,75- Zip ' %D7 Architect /Engineer Address Zip Contractor G4.. AIR eiA/ O% T/Ujl%OLicense #C,.',.Se/MC /q %C Phone y -�/�3� Address /5'L/4w1/1'41 sAti./,'& 4144Y, ! Zip 98/d7 Describe work to be done 'L4 . itwr ♦ . .; G. Oa./ _, /4_ j.NST79Lc. N ' PaG-7"I Rte J /1LS'0- faerhaVA Er/5`rl /N 9R O/V/7- Phone Indicate the type of equipment to be installed, rating /size of equipment, and number of each: TYPE RATING /SIZE NUMBER r;/4RROZ /0 7 .-3• o/2 Two (2) sets of plans must be submitted meeting the application requirements of Section 302(b) and (c), 1985 Uniform Mechanical Code. Roof -top equipment work requires submission of building elevations. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE AND CORRECT AND THAT I HAVE THE PROPERTY OWNER'S AUTHORIZATION TO DO THIS WORK. Applicant /Authorized Agent (signature) Mot.. Date 1267- 1 (print name) %.i4lf e)44,676/ Contact Person (please print) pAck. oz6a/ Phone? 949 s /LKS' OFFICE USE ONLY ►Q'cL /-a5--87 FEES: Basic Permit Fee (000/322.100) $ 15,00 Receipt# -7:P9te Date Paid t_ 3,_1-9 Unit Fee (000/322.100) „x,00 Receipt# •95Sy Date Paid , 31 - Y, Plan Check Fee (000/345.830) (a on Receipt# -7; I4 Date Paid / 3 r _ 5-7 Other ( / ) Receipt# Date Paid TOTAL (OWES: $ 30, 00 ) TRACKINQ DEPT. ATE IN DATE I5DT BLDG PLNG COMMENTS Approved for Issuance / -3o -SI Approved (Initials) M1.':...,. ,.,.... . t43 Vita)' 11/416W aellwaug) .,! /67 tC,T,'' . , .Th /c Row- r i:"-JJ 156-£161 AHU I Nal/ Aoa rhyme) Cam.. N�' F.,Fi k ache /5T/ ,q 2p C3-r�ylN L 0.41.1h. � „M,e.>o. REH0 VV £X /gT // WA/ C? N,64 GP „4/ / /- Ftaovio,, New i" coNop..dkrra p13,41/4 ,erne ex/ g rl/'f 41•/11 -1 exfsr/, cc I cW /TAr . s72110,17* ,a r 5w c w P; O, anir -7 /'-Er , ,j.s.*..t$..' a✓ Lek rs►.a •0► .1„4/P/... 5T /C J!►'SA INA' r/6 T OuCT --�-- 7.761,47* ra . fiuC ;/ 24x/2" ,_-- AIR' tAcwpt,i1A GApccI' t4, 'R »QO‘(2E. Ptu OMATIC> 45 . taad K4(b) gx /577/4 f1.4.a17O ' U/la! / Jar MOu /Jri,1y PAN-P7 ✓ -.k i :Xrl r 5/ Ee wc.4T /Obi X/ 7 /NCB 4NVa - - CLEAit/ 08AL:4/N1 -)tii5771.14 FAN Wile g :MMVE1 EX/ 57 11./ 156,41 / F,5tX4I -ANC 3000 CFM -;c /l -..fir 24° ro ,x/ 9T //14 42"X/ ' F /Lc.o 'vec Y t 4CT $ /ZE - LQG47i' 1. Mechanical contractor shall be responsible for prorer rough -i'n and coordination of mechanical components with other trades and shall maintain architectural elements and finishes. 2. General: All work shall be installed in Complete accordace with local health department requirements. Provide all mechanical work in accordance with Uniform Mechanical Code Uniform Building Code, and Uniform Plumbing code,;_ National Fire Protection Association .13 (latest edition). Washington State Energy Code, and further.requirements of the `local build' ing, mechanical, plumbing, fire and health officials. year commenting be guaranteed parts. and labor for one full 3. All work shall ' y g date of final acceptance in writing. Ductwork', shill be 'construc'ted of galvanized sheet metal materials, gauges and details.as,'recommended in ,SMACNA HVAC Duct .Construction. Standards Metal and Flexible Manual.. Flexible ductwork wall be 11mited to 'five "feet `in- length and just prior to diffusers pr ,gril,las, . suppoitecl every three ";feet as'- recommended`in the SMACNA IJVACDCSM &FI4 manual'. 5. Contractor , `shall submit six copiee of ' catalog' cuts , with specific`in'formation regarding fixtures and equipment proposed and shall, not purchase,, or install any equipment or materials until approval of same 'is received in writing from' Owner. 6. PERMITS: Paid for and obtained by'the Contractor.' Submit ,copies of= 's'igned, approved permits to the Owner's T. Cutting nand,iPatching: All construction materials damaged . g or cut into' during the 'installation' of this work muet>,be, repaired or 'replaced with m ' kis of . like kip and e int as origal ls by skilled labor ex erienced in t h at P i building trade. 8. Penetrations of fire rated elements must' be made Bauch as to retain' fire' rating. (Include Fire Dampers and access doors where, necessary when crossing fire walls, ceilings, etc With ductwork). mgric HANNX CAL MARK ITEM CU--1 Condensing Unit 7EQt7x P'MzTTT MFR'MODEL Existing HC -1 Duct Coil 1 °23M8H. TC, % 7Kwb 8 , 65EER e6MBH ;SC@ 86 F/67 Fwb EAT, b /a "liq, 1= �3 /8 "g1s,, 732 lb. oper.' weight, • 203- 230V•=lph -60Hz 3000cfm .5" Sp (Refurbish co11, blower wheel bearings) 10Kw, 26 x 14 ", 2 stage 208V- 3pb -6OHz , w/4 ,V :.;. switch, thermal cutouts, airflow switch and fuses. !,;1/42/1v rim,//FlenitirM v 9. Record Drawings: Record field changes on record drawing print set prior to each pay request. 10. Clean • u Continuall` remove apparatus, P - y ' equipment, debris, cuttings, crates, cartons, etc:' from site and dispose of in approved waste sites: as directed by Owner. Carefully clean diffusers, grilles, thermostats, etc. 11. Substitution nf Materials 'shall' be made'` only with written' a _ --=t oV /per /CM W- �8V -5 A asocir 424/ TC0 /4. !y 577 26',(1.1" ' z.7 z.7 wav . ACV- 471 Ale 3l. / CUAM CV] -1441q9 V eV/\Tlt4i To cer r 1 f RDI/ /t7o r"' 04r C) RA/ /it/A8 J c7P,Qf // . / -17-/E/2,004W:47- t L.f� c4VE6p) 7'C7 Ex /5T / //6 4//U =/ ' WIT = 't4iii eQv 7 . vo) 14ifiing . ^4fipait t nfv. shai c lih X2 C mar d,r 'in 'Shipment prior :'to "1 installation. paint- `. inside of ` all'°' diffusers and,griilea flat':.black. ' 13 The contractor shall provIde all blocking, curbs, sleepers; and penetrations em required. 14.. All °, equipment ..shall ; be ,-isolated, from �" the structure ''; by vibration isolators and from `- the ductwork ° by : FLEXIBLE CONNECTIONS: 'Requirements: Waterproof, air tight, heat resistant, neoprene coated fabric, 32 ounce. Ventglae, Elgen. 15. Location of equipment shall be reviewed and approved by the Owner prior to installation. 16. The ''contractor shall :perform' an on -site Operation and Instruction Demonstration "for the Owner. or !Owner's agent, describing the -'location and operation `of all equipment 'including controls and demonstrating that the system meets the proposed designoonditions. 17. 'Final certification shall be b' Owner's agent, contractor Shall :be 'responsible for r adjustment, start up. and general balancing prior';to final certification, and prior to balancing and occupancy by Owner, ;tesst and adjust, fan, ,,dampers, temperature controls, etc.,?for proper operation," Recheck all equipment and systems after certification is`complets to confirm operation' of` all systems'is ".fn accordance" with plans and specifications. 18. Conflicts: Should conflict. occur, - either mechanical or electrical, due -to substitution of fixtures,' equipment'or materials ' from those which' the' mechanical ` design ` is based, the Contractor is responsible for all costs,` incurred. Any redesign :required shall '' be. ' at .,the Contractor's expense. Redesign: and /or" modification to. the`. contract documents will be by'Walnut "Hills Engineering'on a time And materials basis and paid for`by the Contractor. 19. F'LEnaLE DUCT.,- Requirements: UL, approved, 'complete with aluminum flexible interior liner,`1" insulation and exterior vapor, barrier." United Sheet. Metal, or Johns- Mantti lira equal ` to Cievaf lex models as follows: 'Low; Velocity: SFV 20. WIRING'General: install in accordance with requirements of the National'Electric Code. All' wiring shall be ;provided by Li : //3OV /O &.,410W /2 "0. r icr -SON T 7_ x/ 6. l7/N (r rP) WILA FILE COPY `. . inderstand "that the Plan Chock approvals are sublecf'tn errors a;id omissiof3 and approvai'of. plans does" not oi, ^ncrir, tlye vloiatiof of any , edapfezl cc a Pc-ceipt of contractor's copy of approved plans acknowlcti ed, Q,�.n �,� r,; it No. !. .,:. ."4..04 .,. v. ......cr leaWraeg3 "'Wa4a+'�..VaaWi?i.:. 'i;'�yJ � '''' ��` �. �%: �' �,. �iih`!- 7-+ �k��fi,a!•!;wns*- Ye!wr!,yw� ==�s I1 II1111 11Ii1II II1 !hIrli,Ili11111hI1JI,I1'II''II hIl'hII IIi11111II'I ,G THS INC• 1 2 • >:•4P Win, `p. ti •:r la-kw te yfi : Y •o L.i.b •�i I: I II1II1I` 111111 111111l illI 11I1I III1[1I1IIi1III {I IIII wI f ,t0 .... :microfilmed document i5' less, clear `C an this P,-- ► , i t 'is , due to the quality` of the original document ' �. +. , 'G, ' 6++s« s .airs .,s, ,I .. ,7 ' rd's.. a 2i4,.yaw; w+wuaJa. 1. 5l. *IL "ff £il (l `' t. G 9 s 7 e L ' ww o .al.:.; .,. ,;i „,,®, w» u. ,.:, ;:: M " :.� ,: , . 'ir, y -�" .,;. • ,. , ; . Bill linnIIIIIIIiilliiiiIIIIIIft iIIIII�Ii nliuii,iiInil1Inilliii��iiilii � Ii1l0111iill ��iIIIII 01111i(il1i�Iliikrilini1i1�i�I� I :I' l�nu IHimiliIil i oliliiiri iIi�rill' 11(1.06 (1ml