Loading...
HomeMy WebLinkAboutPermit 0087-M - Egbert ResidenceCITY OF TUKWILA (- Building Division 6200 Southcenter Boulevard Tukwila, Washington 98188 (206) 433 - 184-9 BUILDING PERMIT Control # 88 -088 -M PERMIT # 60 �-r —Al Work to be done Site Address Building Use Property Owner Address Contractor Address HVAC (CHIMNEY INSTALLATION) 5612 S. 133RD Suite # Tenant TERFSA FIRERT RESIDENTIAL Assessors Account # A Phone #t 839 -1672 DAN & TERESA EGBFRT 29043 59TH PL_ S. (SELF) FOR BUILDING PERMIT ONLY AIIRUURN, WA S Ft. Sq. • Office St Warehoorage/ use Retail Other Occ. Load si t FT. 2nd FT. 3rd FT. Total _ , Fire Protection: ❑ Sprinklers ❑ Detectors Zoning Type of Construction Special Conditions THIS PERMIT APPLIES TO INSTALLATION OF METAL CHIMNEY. IT DOES NOT INCLUDE E, Phone # Zip 98001 Zip Fees sq. ft. @ 1st F1. $ sq. ft. @ 2nd F1. $ sq. ft. @ other $ sq. ft. @ other $ Total Valuation of Construction $ 200.00 Bldg. Permit Fee Receipt #4240 $ 15.00 Plan Check Fee Receipt #1,24,0 $ 4.50 Demolition Receipt # $ Surchanggl,„ Receipt # $ Other Receipt #4.2-4.0 $ 19.50 Other Receipt # $ Completed work without a permit 39,00 TOTAL $ FOR SIGN PERMIT ONLY ❑ Permanent ❑ Temporary 0 Single Face 0 Double Face [] Wall Mounted ❑ Free Standing ❑ Other Building face Setbacks: Front Side Side Rear Square Footage of each sign face Total square footage of sign ISpecial Conditions ■ THIS PERMIT BECOMES NULL AND VOID IF WORK OR CONSTRUCTION AUTHORIZED IS NOT COMMENCED WITHIN 180 DAYS, OR IF CONSTRUCTION OR WORK 15 SUSPENDED OR ABANDONED FUR A PERIOD OF 180 GAYS AT ANY TIME AFTER WORK IS COMMENCED. I HEREBY CERTIFY THAT 1 HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE AND CORRECT. ALL PROVISIONS OF LAWS AND ORDINANCES GOVERNING THIS TYPE OF WORK WILL BE COMPLIED WITH WHETHER SPECIFIED HEREIN OR NOT. THE GRANTING Of A PERMIT DOES NOT PRESUME TO GIVE AUTHORITY TO VIOLATE OR CANS CEL THE PROVISIONS I OTj�R STATE, OR LOCAL LAW REGULATING CONSTRUCTION OR THE �E@�ORMANCE OF CONSTRUCTION. Sigrte "_� i.%C�er�e ,,,17.-7— '�' Date / (} LICENSED CONTRACTORS DECLARATION 1 hereby affirm that 1 am licensed under provisions of the Business and Professions Code, and my license is in full force and effect. Date Contractor (signature) OWNER- BUILDER DECLARATION ( ) I, as owner of the property, or my employees, with wages as their sole compensation, will do the work, and the structure is not Intended or offered for sale. ( ) 1, as owner o th roperty, am exclusive' ' ont[ tilSensed contractor's construct tile Owner (signature) ��' , CITY OF TUKWILA Building Division 6200 Southcenter Boulevard Tukwila, Washington 98188 (206) 433 -VW ESQ BUILDING PERMIT Control # 88 -088 -M PERMIT # 7- 4j Work to be done Site Address Building Use Property Owner Address 29043 59TH.PL_ S. Contractor (SELF) Address HVAC 5612 S. 133RD RESIDENTIAL DAN & TERESA EGBERT (CHIMNEY INSTALLATION) uite enant TFRFSA_EGRERT Assessors Account N NSA Phone #► 839 -1672 FOR BUILDING PERMIT ONLY AIIRIIRH, WA Phone # ZTp —'001 Zip Sq. Ft. St . Office Storage/ Warehouse Retail Other Occ. Load 2nd F1. 3rd Fl. Total Fire Protection: ❑ Sprinklers ❑ Detectors Zoning Type of Construction Fees sq. ft. @ 1st F1. E sq. ft. @ 2nd Fl. $ sq. ft. @ other $ sq. ft. @ other $ Total Valuation of Construction $ Bldg. Permit Fee Receipt #IG 2Cu $ Plan Check Fee Receipt #L2 4. $ Demolition Receipt # $ Surchanggl, Y Receipt # $ Other Receipt #I,. o $ 19.50 Other Receipt # $ Complete workwwi without a permit TOTAL $ 39.00 200.00 15.00 4.Sn =Mali IIIIMAC1==11111MIS Special Conditions THIS PERMIT APPLIES TO INSTALLATION OF METAL CHIMNEY. IT DOES NOT INCLUDE INSTALLATION OF STOVE FUR SIGN PERMIT ONLY ❑ Permanent [] Temporary ❑ Single Face ❑ Double Face [] Wall Mounted ❑ Free Standing ❑ Other Building face Setbacks: Front Side Side Rear Square Footage of each sign face Total square footage of sign Special Conditions THIS PERMIT BECUMES NULL AND VOID IF WORK OR CONSTRUCTION AUTHORIZED IS NOT COMMENCED WITHIN 180 DAYS, OR IF CONSTRUCTION OR WORK IS SUSPENDED OR ABAN00Nt,U FUR A PERIOD OF 180 DAYS AT ANY TIME AFTER WORK IS COMMENCED. 1 HEREBY CERTIFY THAT 1 HAVE READ ANO EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE ANO CORRECT. ALL PROVISIONS OF LAWS AND ORDINANCES GOVERNING THIS TYPE OF WORK WILL BE COMPLIED WITH WHETHER SPECIFIED HEREIN OR NOT. THE GRANTING OF A PERMIT DOES NOT PRESUME TO GIVE AUTHORITY TO VIOLATE OR/ CANCEL PROVISIONS 0 (/ STATE, OR LOCAL LAW REGULATING CONSTRUCTION OIt�THE �E MANCE OF CONSTRUCTION. °� LICENSED CONTRACTORS DECLARATION I hereby affirm that I am licensed under provisions of the Business and Professions Code, and my license is in full force and effect. Contractor (signature) Date OWNER- BUILDER DECLARATION with wages as their sole compensation, will do the work, and the structure is not intended or ontractin with "eased contractor's to construct the proje t /r2L2 �! oat. // 7 - ( ) 1, as owner of the property, or my employees. offered for sale. ( ) I, as owner of th /roPerty, am exclusive' Owner (signature) l- {� 3bYtMranuat tW1 `rate- l?6Ufli2Ytiwiaxi! CITY OF TUKWILA Building Division Boulevard (206) 433 -1849 n++m rxr v+0.000.. ,0.0.w.400.0•.. 0.040.nwoa 040000Mw.e v.•wuw,000.0 a004 .eavw.........w..w.,00•4.....,+, 0.0 000 0401... 7 .010u000tYAX:id*20MS,,22,!1MSCI 40i.:.. INSPECTIle RECORD PERMIT # 00/ 7-/11 Date //— g—gX //:30,1„, ype of Inspection • Date Wanted 7-1/444,2_ //40.11 .m. p•m• i to Address SO, /'_. ,S Yf y ref( Project 7 ire- c equestor %pJti� lc Phone # 8i /..-- /e 7 z pedal Instructions Inspection Results /Comments: 0M T2 f';41497__. /44f14/' / Mh/ i // 4M A4.' kt/ /f, ,i0A4 al a /7//kt�it//.� Inspector Date /C,. 2100° The ultimate in chimney safety with exclusive snap-lock installation ease. Our : ,# tweighty eas - to- IPistall desi * wakes It "snap" " to use P Air -Jet 2I;0 the ultimate in chimney safety rrFt 3 r . The true beauty of your AIR -JET chimney system is not only in its high temperature design, but also its ease of installation and Tong -term safety. An AIR -JET chimney system can be fitted to your particular needs and design plans. It's useful for all types of heating equipment — stove, fireplace, furnace, water heater —and for all types of fuel —coal, oil, gas, wood. It's versatile, can be installed inside or out, and can be used in multi- story applications. It's a one -man Job. AIR -JET pipe and fittings are so lightweight and simple to install, you can do the job alone. Complete instructions are packed with every handy carton. Parts snap -lock together easily to form a safe, rigid installation. You can get a complete range of special purpose parts and finishing accessories. Extra - strong, triple -wall, air - insulated construction is your assurance of long service and safety. 1 4 1 1 .;:■‘ 4 1 • ft • \ I', =2. • • • () :::LfJ llimn-"•-.77',/ .70 -. z WED s'l -LLY . 1 • l 0.. ZeicS ,.--Q,ali Sw= 0c ' cp = ..404111 j11: g '5= (-5 ;,• 1 (.) • • • 11 (r); • • • Li (1' Pog C— 411 , ::„,, .,_: .. 75 :: . • • ... . ' , J., ,ii., . :3 ,,, 4 k; 0 6) 13 ''.. . • • . .: , z: ,- 1 ,--) c.,,-En- . , E.,-, ,, 52 E 'i • t L-13) 8 .........: • ..., . „ ir ,._ < !•‘• c. -C 0 0 Li a) c = (E) E a) a) co — 1- (11 (1) o +- C c.) Dczo).5..zwiza) • „„a3 o_ 0 a) 0 _c •-• Et -o >, C u) 6 S c) Ez o (..) 1-03 (Z) (Ef3 r) _ — En En c _o .c as .— En 0)•— 0 u) ,U) 0 a) ova- •c •- u) .- (1) 0 ..., lii FD L'.). T5 S3 t) 1— •-• 1-6 . — -6 8- -o (..) E1.2 RS • - 0 75 . -c -0 o {1 if a) ) u) -o c.) c 0 .a) .6 .174 .601.1.r.7a4.77.711RIVIIM a zh ....., .0 (t; r2m 6 _i ._ •... Ela a) a) E 7: (7) vi i 15, iii E2 .0') 0..-- oo i 4 a ) > MS 0 • a) 1:3 .1-.' E 6' . 0 a 5 a) '0-) Ea m5 0 Cni 1:3 c C -■-■ 0 > . 178 005 ...= c) E , 17; cz 2,..cri s 8 0 ,... .0 ,,, _. c E ca 15 = .a w 000.--• oU ,5 ..- .4-C3C-3:c- 0 • c 0 0 a) co 0) a) Cr (I) •—• -C .... , Ets al ..c ci) ti3 E c ..„..9- 2- "0 0 a)) c!' c') E .0.Caic00.•-• I I c 1.;D: 1 ::" 11 um °>" 2 >ti9 2E (10) 2 -C 03 •C Wou) '0 CL -0 .0) C = E Et_i a' .0 c 0 E 2 `al g a) as (..) Ezi a) 177). . 0 o r, .-• .c o o .. N .. ,`.-. -- > , . ;...-.•; o 7. 3 fel -C 1:2 Z 0 0 CC (..) I— '..= ° '4"--.- V' c u) If) 13 al 2 6. Ask your dealer for special code requirements. One -oft -kin Air -Jet 21 , O° w ffers these unmatched features. Lightweight Design. Ideal weight for handling and installa- tion. Loss than half the weight of most 21000 pipe. Exclusive Snap -Lock System. Assembly is quick and easy. Just line up outside seams and push down until pipe "snaps" into place. To disassemble, simply twist counterclockwise and lift. Easy Framing Dimensions. No cutting of ceiling or wall joists necessary. Unique Telescoping Through - the -Wall Tee Assembly. Only tee assembly of its kind that fits between standard joists (16" O,C.). The result: a flush inside wall connection without a chimney extension in the room. £-aclusive Dripless Connectors. Integral dripless connectors are built right into the starter section or tee. This eliminates the micd for "stove pipe adaptors" to connect the single -wall stove !o the Air -Jet 2100° system. t.engths. Available in 4', 3', 2' and 1' lengths. toot Flashing. Unlike many systems, the Air -Jet ,,,ning is designed without ventilation holes to prevent or entry of unwanted animals or debris. -tple Air Insulated Design. The Air -Jet 2100° ,`;es all three methods of heat dissipation— convec- iection and radiation to safely eliminate heat build -up .,.a your home. c:icer Inner Flue Liner. Provides an extra margin of NEW LUM8U HAADWARE co. 30854 • Pacific Highway So. at Fudorai Way, WA 98002 Quality and Service For Over 35 Years AIRMET General Products Company, Inc. P.O. Box 7387. Fredericksburg, VA, 22404 Phone 703/898-5700 CM -31 5/88 20 The ultimate in chimney safety with exclusive snap -lock installation ease. 41 _---1-IRET Exc.( Snap-Lock Speed No twisting, no screws. Just line up seams, sn tightly locked by AIR-JET's exclusive design. install a chimney quickly and economically. r. we Features s together. They are the job. One man can Itive 1 Housing in -ctionai Kit ;; togethei for ••-olarl assenibly cifl tooft; 17" x 1/ red nr :t(?(.11 t)I t„ 1 whIff.• rH1 •)••:•.,;•,,%;ith ,•• ri 4. • • 1Nith strips of plumbees.tppe, , centerthe Chimney sections in the roof- opening.' ' • , position'. Oa not twist " ,e,:uniess you intend to mble. Exclusive i-eatures Snap -Lock Speed No twisting, no screws. Just line up seams, snap pieces together. They are tightly locked by AIR -JET's exclusive design. Faster on the job. One man can install a chimney quickly and economically. Decorative AIR JET Housing in Conventional Kit Parts snap together for quick. one -man assembly with no special tools. Measures 17" x 17 ". Available in plain red or bu'' ,imulated red brick or iulated white hry , Ilse with H. iI .. *exception . of the starter section, all pipe US be. installed: with 2" clearance to combustibles nIee prq acted by joist shields. Installin • Chimn 'Insert the ceiling cover/base sup- port from befbw the opening and raise until the flanges are in contact mith the ceiling. Drive 8d nails through the pre-punched holes. Install the stainless steel all- fuel cap, making sure that it .is locked securely to the top of the final pipe SeCtion. with the ceiling. Drive 8d nails through the pre-punched holes. Install thqstainless steel all- fuel cap, making.sure that it is •locked securely to the op of the final pipe section. The safe way to save energy and installation costs—burn wood, oil or gas The only 210Q0 triple- wall, air - insulated metal chinnney. Built -in quality and safety for all fuels. The improved technology behind the Air -Jet 2100° triple -wall, air - insulated metal chimney system qualifies it for safe use with all fuels — solid, liquid or gaseous — used to fire: • wood stoves • free - standing fireplaces • masonry fireplaces • oil- or gas -fired appliances • light commercial and industrial appliances • domestic incinerators Considered the ultimate in high - temperature chimney safety, Air - Jet's 2100° system offers the same convenient dimensions and unique locking system as the original all -fuel design, yet pro- vides increased margins of safety to meet national code requirements. 2 • Air -Jet 2100° starter section. An integral part of the Air -Jet 2100° system, the starter section acts as a safety valve at extremely high temperatures. Above these critical flue temperatures, the starter section inhales cool air from outside the chimney to help maintain a safe, even temperature inside. Exclusive dripless connectors are built right into the starter section, eliminating the need for "stove pipe adapters" to connect single -wall Starter sections required with CKS, stove pipe to the Air -Jet 2100° RSK and HL kits (not required with system. OTK kit). See page 4 for details. Exclusive Snap -Lock system. • Static air system during low firing conditions. Thermo- Syphon air action during high temper- ature conditions, including chimney fire, insures complete safety. Uniform protection throughout (no hot spots). Four pipe lengths, including exclusive 4' lengths. Lightweight design for easy handling and installation. Easy framing dimensions require no cutting of ceiling or wall joists, in either 6" or 8" diameters. Galvanized outer wall to resist atmospheric /corrosion (018" thickness). Aluminized steel intermediate wall to reflect heat Inward. Stainless steel inner wall to withstand maximum temperatures and to resist solid fuel corrosive .015 thickness thickness for extra margin of safety. Rolled male end. UL 103HT listed. Tested by Underwriters Laboratories. Listed to UL 103HT which has temperature requirements as follows: 2100° for three 10 minute intervals 1700° for 10 minutes 1400° for 1 hour 1000° for continuous burn Engineered for efficiency in operation and installation. Prefabricated metal all -fuel chimneys save substantial money and space when compared to conventional chimneys. And they are simple to install. Unitized construction. Multiple wall design makes use of air insulation and also creates a better draft action. Walls are bonded together as a single unit, designed to slip easily into its companion section. Lightweight for one -man installation. Engineered for labor savings, Air -Jet chimneys are light- weight. One person can install the chimney quickly and economically. Unique Snap -Lock design. An exclusive Air -Jet feature. Assembly is quick and easy. Just line up outside seams and push down until pipe "snaps" into place. To disassemble, simply twist counterclockwise and lift. Special 2100° features. Exclusive adjustable snout tee. The Air -Jet adjustable snout tee, in 6" and 8" diameters, is the only tee assembly of its kind that fits between standard joists (16" O.C.). The result: a flush wall connection without a chimney extension in the room interior. Accommodates approx- imately 41/2" -81/2" wall thicknesses. For thicker dimensions, simply add extra pipe. Includes dripless connector. "Closed" roof fleshing. Unlike many systems, the Air -Jet 2100° flashing is designed without ventilation openings to prevent rain Teaks or entry of unwanted animals or debris. 3 Packaged kits save time and mone y. All accessories conveniently packed in cartons. Easy to order, inventory and store. So handy on the job! CKSCeiling and Roof Order: CHASE KIT & HTK KIT CS1 Storm Collar Starter Sect on (Contained In HTK KII Round Termination Cap Boot Flashing W12to 6112 Pitch Ceiling Cover Base Support Matte Black RSK"A" Frame Order: ROOF SUPPORT KIT Round Termination Cap Attic Insulation Shield (Contained in HTK Kd) Storm Caw Starter Sect on Root Support 4 Boot Flashing (High pitch available on order) OTKThrough- the -Wall Order: OUTSIDE WALL KIT 3 Wall Bands Round Termination Cap Weather Shield Adtustable Wall Thimble Matte Black Face Plate Matte aleck H L Decorative Housing Order: CHIMNEY HOUSING KIT & HTK KIT Top Cap t8 Stainless Steel Telescoping Section Boot Fleshing Attic Inset/Mon Shleid (Contained M HTK Ka) Ceiling Cover Bas. Suppor t Matti Black Starter Section Contained in HTK Kit) Its easy to order Air-Jet® 21000 Air -Jet 2100° all -fuel chimneys are easy to all -fuel cIhiIIllrleys. stove, when h you ore venting a furnace, stove, �r�ater heater or fireplace burning oil, gas or wood. To determine number of chimney sections necessary for a chimney height of 25' or less, use chart below. NOTE: When using starter section, subtract 1' from your chimney height to get total amount of pipe needed. • 1. Select a kit. Determine what type of installation you need (see CKS, OTK, RSK and HL Page 4.) You will get all needed accessories packaged as a kit. The kit does not contain pipe sections. 2. Determine the diameter of pipe. NOTE: The appliance, stove or fireplace will recommend a pipe size. Inside diameter of Air -Jet pipe should match diameter of single wall pipe coming off your appliance, stove or fireplace. 3. Determine total length of pipe. To determine triple wall chimney requirements, measure from the hole in the ceiling or wall (first combustible surface) to the top of the installation as follows. Top of pipe must be 2 ft. higher than anything within 10 ft. of the chimney, and a minimum of 3 ft. above roof. Order longest sections available. Ex. You need 9 feet of pipe. Get two 4 -ft, sections and one 1 -ft. section. 4. Determine chimney offset needs. When calculating amount of offset needed, include radius of pipe (45/16" for 6" and 65/16" for 8 ") PLUS 2" clearance for total offset from center line of 65/16" for 6" and Vie" for 8 ". NOTE: Dimensions shown are theoretical. Manufacturing tolerance and installation variance can combine to create a total tolerance of + or - approximately 5. Select your Air-Jet roof flashing. Determine the pitch of your roof by using one of the methods listed below. 'Then use the handy chart to see where your roof pitch falls. Example a 4/12 pitch roof falls into the 0/12 to 6/12. A. Rise over Run A 4/12 roof Is determined by measuring the vertical rise (4 feet), over the horizontal run (12 feet) to get to this rise. This method is always expressed X /12. B. Pitch This method is expressed as a fraction of a full pitch (24/12). A 4/12 rise /run roof is expressed as a 1/6 pitch (4/12 divided by 24/12 s 4 divided by 24 or 1/8). C. Degree Measure A 4/12 rise over run, or 1/6 pitch roof Is also an angle of 18.4 degrees. Chimney Height Plpe Length 4 3 2 1 6' 1 1314' 1 101/4' 7' 1 1 341/4" 3' 8' 2 4' 283" 541/4," 9' 2 851/4" 6' 1 10' 2 46114" 1 6' Pxaoburn dis.i) 11' 2 1 12' 3 13' 3 1 14' 3 1 15' 3 1 Chimney Height 18' 17' 18' 19' 20' 21' 22' 23' 24' 25' Pipe Leng h 3 2 1_ 4 4 4 4 1 5 5 1 5 1 5 1 6 a Chimney Offset Chart 30° Elbow (Offset) (6S30, 8S30) A - Amount of pipe In between pair of oflu elbows. B - Amount of offset centerline to centerline realized by pipe and ells. C - Amount of actual height added by pipe and ells. This is the actual height added excluding locks. Minimum 3 ft. 1110' or less chimney must extend 2' above peak. 6' Diameter Chimney A Dimension No. 01 Ft. of Pipe B Dimension Amount of Offset C Dimension Amount of Rise 0 glad m 9.c■ axwnl 414" 1314' 1' 101/4' 2314" 2' 163" 341/4" 3' 221/4" 441/2" 4' 283" 541/4," 5' 343" 851/4" 6' 401/4" 751/4," 7' 46114" 66" 6' Pxaoburn dis.i) 523/4" 9634" a' DIem.ter Chimney A Dimension No. of F1, of Pipe B Dimension Amount of Offset C Dimension Amount of Rise 0 (Back la Back .Iba..) 5" 17" 1' 11' 27415" 2' 17" 373" 3' 23" 481/4• 4' 29" 581/2" 5' 35" 86/4" 6' 41' 7911' 7' 47" 69%" 8' (ua,uwm awn 53' 100" Putt Pltoh 14 Pilch 1h Pitch V, Poch 15 Poch V, Pilch ;4 Pilch Rise /Run 24112 18112 18112 Degree Angle 835 19/12x24112 5,9 1311210 10/12 12112 45 0(12 8112 •Fx 4112 114 9112 10 8112 MF\Flai 1 Roo/10(12) t2 5 1 Components and accessories —'I la Offsets "—'D� —A —N 4.. ,,._ ^,, � o �I��;s .. I*. '. j'' —'A 1• T . B Ai .Stainless Steel Lined Ch mney Pip Sections All chimney sections are engineered for fast installing with no -twist Snap -Lock design. • Light weight. Meets all National Code Requirernents. _� — _ A ,,s . =" a� —{- C Starter Section Available in HTK kit 1 J 30° Offset One 30° Elbow (2 30° Elbows) See offset chart on page 5. only. A Length B Outside Dia. 6SS 8SS A B C 0 A B C 8%" 12" 11/4" 125/6" 12" 11/4" 6S 1,2, 3, 4 8S 1.2, 3, 4 10J 2. 3 12 ", 24 ", 36 ", 48" 12 ". 24". 36 ". 48" 24", 36" 85 /e" 125 /e" 1514' 30° 6S30 8S30 10J30 45!16° 35/16" 35 /e" 27/e" 49he" 7V2" 133/6" 17" 20 "/16" 43/e" 5" 513/6" t k fin•' v• :;ar.;.",• fi"• lY li .9 A I i t F`-- ,.,0 Trim to roof slops Y4 III 1 1I I I 1 Support (10 ") l C 4W7 /� /—L Tee I Pr Support (6 ", 8 ") Wall ', .''" L B _'1 Roof Support T Ceiling Cover J Base Support (6 ", 8 ") Base Support (10 ") 6" and 8" bases are designed for easy Instal - lation In standard 16" on center joist spacing. 8SWS 8SWS 10JWS 6SCCB 8SCCB 10JBS 6SRS 8SRS 10JRS A B 16'14" 1254" 16'14" 15'4' 22" 19" A B 125 /e' 4" 14'/4" 4" 19" 4" A B 18" 12 "/16" 18" 145/16• 18" 191/,6" .. 16 -A -4j Storm Secondary flashing helps Installation. A Round Termination Stainless steel cap protects dralts. Collars assure leakproof Cap against down �—C —� Attic Insulation Shield Available in HTK kit only. • ISIS ISIS 6SSC 8SSC 1OJSC 6SU 8SU 10JU A B C 121/2" 111/2" 14%" 161/2 11'h" 18%" A B 1254" 2'a" 163'/34" 3'14" 19'/4" 4" A B 11" 5' 4" 15" 11)G" 25" 14'/16" Extra - ing ad)usts j'r . High Pitch Flashing* [..._ A --4 Tall Cone Flashing (Flat Roof) Should be used on all flat roofs to protect from standing water or snow. Its 12" height greatly reduces chance of leakage. 0 --44 Ad)ustable Boot Flashing strong, leakproof flashing. Standard flash• from 0/12 to 6/12. SUFI I8BFT tOJBFT 6SBF ISBF r 10JBF BFX BFY BFZ Specify pipe size and pitch of roof 7/1210 12/12 13/12 to 18/12 19/12 to 24/12 A 8 12" 12" 145 /6" 12" 16'/4" 12" A B 55/5" 13/4" 7 14' 16'/4" 5" 20" 6 • • • .....- • ,, ... ...:, 1-- -I ,(:.,,V . hi-- A---d Joist Shield For multi•story applications. Install on under- side of ceiling joists. Adjustable Snout Tee For through-the-wall installation, ,...._ --44 Firestop Assembly For multi-story applications, install on under- side of ceiling joists. 6ST 8ST 10JT 6SJS 8SJS IOJFS A B C 145/e" 61/4" adjustable 201/2" [ 93/ie 259/i 6" 1 12.66. A B C 145/e" 12" 125/e 16'12" 12" 1431e Dia. A B 2134" 1" . Wall Thimble For use in passing through a wall. accommodate different wall depths. ,:.... . . . ,.,,,.... , • '','-‘„'••--- , ' - '-.- <Dm *lather Shield For weather-tight protection in through-the-wall Installation. Place against wall around tee and caulk for sealing. Adjustable to F ace Matte Plate Black 6SWT NWT I 10JWT ISSFP 8SFP A 8 C " " 13' 143e 21 16'4 Ag adjustable from 4%2" to 8" 12%" I 13" 1 171/e 6SW8H SSWSH 10JWSH A 6 1/2" 8“1,6- 'h.. 1211/16.. A 14%" 161/2" 2115/4' Inside-Outside Diameters .441111631raintr Ii%',Is'-.)• Rona - ,„.,, i'fit 1:ifirm e '' - • .; :cif • '.'..t', - 4 l • •-• 0,41 ;f:: '4( c.."4,...t — ' • , :.;;;..., .. , Chimnity Housings For 6"and 8" diameter pipes, these decorative housings are available with rancher top In red brick pattern or solid off-white. Sizels17" x 17". For 10" pipe, the housing size Is 22" x 231/2", All housings are 3' or 4' in height. Kit Includes base support, flashing, 18" telescoping connector, four panels 8 top cap. -4.i --<.*' 411M10. A -----. Wan Band Clearance to 0 I A 0°D. .O. combustIblesi --04 c Note- Maximum height for 6, 8 & 10" chim- neys- 50'. A A Inside Diameter 6" 8" 10" B ' Outside Diameter 85/e" 125/e" 151/4" GEMS • 8SWB 10JW5 A 105/4" 81/2" 1434" 121/2" 17'/4" 151/4" C Clearance to Comb. 2 _ r 2" NOTE: 6" + 8" Air-Jet chimney systems listed to 2100° UL 103HT 10" Air-Jet chimney systems listed to 1700° UL103 7 AIRJET From paint -of -sale to final installation, • Air-Jet °s 21000 program comes out on top. Air -Jet, along with A.J. Sweep, our easily recognizable symbol of quality and safety, support your sales efforts every step of the way. A full -size, attention - getting display provides customers with important decision - making facts. The handy take -with literature outlines the quality and installation ease of Air -Jet's 2100° chimney system. Plus, newspaper ad slicks are available to complement your merchandising program. Packaged kits: an extra convenience for you --and your customers. Air -Jet's 2100° kit accessories come conveniently packaged in informative cartons. • big time and money savers • simplifies inventory —fewer SKU's • easy to order • attractive, 4 -color graphics for greater consumer appeal Installation ease indoors and out. Top to bottom, Air -Jet 2100° chimney systems provide the ultimate in chimney safety with exclusive snap -lock installation ease. And thanks to the unique design of the starter section, you can expect a beautiful, drip -free connection with most conventional interior stove pipe. Distributed by: NEW l_U,'rir'r.,l • 6: ,-AROWARE CC). 30854 Pacific H- 14hway So. rat Federal Way, WA 98002 CH•66 5/87 15 Printed in U.S.A. Quality and Service For Over 35 Years AIRRET GOe. n Ucs 7307 • i"d" cliaburg, 22404 Mare 703/000.0700 CITY Of TUKWILA Building Division 6200 southcsntar Boulevard MECHANICAL PERMIT APPLICATION Tukwila, Washlnotnn oKIU (206)- 433 -1849 ti•. CONTROL# n - d 21 -' l Site Address „:;r67/02 6c) X33 77-e;_ic , k._ Suite# Floor# Project Name /Tenant .%%rte L .946e1-i Valuation of work 6 C C) A ssessors Account # Property Owner ;Dint) d /e/1 t5 Z 2 eY/ Phone 8, — /6. 72_ Address .2401/3 51 n io 4e,r-w GvW Zip 90C-) Applicant Same Phone Address Zip Architect /Engineer Address Zip Contractor 0l.2/169r License# Phone Address Zip Describe work to be done -)A1i%x)?e Phone Indicate the type of equipment to be installed, rating /size of equipment, and number of each: TYPE RATING /SIZE NUMBER Two (2) sets of plans must be submitted meeting the application requirements of Section 302(b) and (c), 1985 Uniform Mechanical Code. Roof -top equipment work requires submission of building elevations. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE AND CORRECT AND THAT I HAVE THE PROPERTY OWNER'S AUTHORIZATION TO DO THIS WORK. Applicant /Authorized Agent (signature) Ail p . 74 Date /1— 7-04 (print name) / :l�c°jL may, Contact Person (please print) r/we_ c Phone D�%� 7/60 % 7 OFFICE USE ONLY FEES: Basic Permit Fee (000/322.100) $ /5a`0 Receipt# 4,2C 0 Date Paid /r- 7 -Cr- Unit Fee (000/322.100) 51.6-0 Receipt#► Date Paid Plan Check Fee (000/345.830) Receipt# Date Paid Other ( / ) Receipt# Date Paid \/ -ir MAL -11 = 391Ja(OWES: S -% ) T I RA�K DEPT. ATE IN 1 BLDG PLNG DATE OUT COMMENTS Approved for Issuance Approved (Initials)