Loading...
HomeMy WebLinkAboutPermit 6952 - Questar Center - Retaining WallJESTFR U1LD1G PERMIT (POST WITH INSPECTION CARD AND PLANS IN A CONSPICUOUS LOCATION) CITY OF TUKWILA Dept. of Community Development- Building Divisio 6300 Southcenter Boulevard, Tukwila WA 98188 (206) 431 -3670 BUILDING PERMIT NO. DATE ISSUED: L SITE ADDRESS DESCRIPTION BUILDING PERMIT FEE . PLANCHECK FEE. BUILD.ING:SURCHARGE< AMOUNT RCPT:# 631` 00 410:'.00 4051 DATE PLAN CHECK NO.: 91 -464 PROJECT INFORMATION 15425 53 Av S SUITE # PROJECT NAME/TENANT Questar Center VALUE OF CONSTRUCTION - $ 98, 257.00 ASSESSOR ACCOUNT # 115720 - 0033 -30 TYPE OF ❑ New Building LjAddition JTenant Improvement (commercial) U Demolition (building) U Grading/Fill WORK: ❑ Rack Storage 0 Reroof ❑ Remodel (residential) ❑x Other: Retaining Wall DESCRIBE WORK TO BE DONE: Erect a crib —bin retaining wall (120 linear feet in length, 15 feet in height) to replace existing rockery. PR•P R *INNER First Capital Partners Ltd. PH •N 383 -7111 ADDRESS 1450 First Interstate Plaza, Tacoma, WA ZIP 98402 CONTRACTOR Retaining Walls Northwest, Inc. PHONE 747 -0956 ADDRESS 1299 156th Avenue N.E. # #150, Bellevue, WA ZIP 98007 WA. ST. CONTRACTOR'S LICENSE # RETAIWN1150.T EXP. DATE 8 -29 -92 ARCHITECT PHONE ADDRESS FL CODE COMPLIANCE• ~• • ZIP SQUARE FEET OCC. LOAD SQUARE FEET OCC. SQUARE OCC. LOAD FEET LOAD SQUARE FEET OCC. SQUARE OCC. LOAD FEET LOAD .................. TOTAL SQUARE FEET TOTAL OCC, LOAD :: W- r PROTECTION: 0 NA UTILITY PERMITS r r M Yes 0 No ZONING: BAR /LAND USE CONDITIONS? ❑ Yes ®No CONDITIONS (other than those noted on or attached to permit/plans) APPROVED FOR ISSUANCE BY: BUILDING OFFICIAL DATE: 3 - CIS I hereby certify that l have read and examined this permit and know the same to be true and correct. All provisions of lave and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. 1 am authorized to sign for and obtain this building permit. SIGNATURE: /LA_- a 6 PRINT NAME: r. A G.0 /1S This: permit shall bocome null and void tf the work is not commenced within : 80 days from the issuance, or f the work is <suspended or abandoned for a perrod of 180 days from the last ins DATE: LI 7 t q COMPANY: eekuv1tri CERTIFICATE OF OCCUPANCY NO. DATE ISSUED: it BUILDING ',PERMIT APPLICATION TRACKING PLAN CHECK NUMBER 9t--1-4(0-1 PROJECT NAME UJf3k o C2 i "-eY SITE ADDRESS . ! SUITE NO. 5 55 -) INSTRUCTIONS TO STAFF • Contacts with applicants or requests for information should be summarized in writing by staff so that any time the status of the project may be ascertained. • Plan corrections shall be completed and approved prior to sending on to the next department. • Any conditions or requirements for the permit shall be noted on the plans or summarized concisely in the form of a formal letter or memo, which will be attached to the permit. • Please fill out your section of the tracking chart completely. Where information requested is not applicable, so note by using "N /A ". BUILDING SQUARE FOOTAGE/OCCUPANCY INFORMATION (to be filled out by Plan Checker) SQUARE FEET OCC. LOAD SQUARE FEET OCC. LOAD SQUARE FEET OCC. LOAD SQUARE FEET OCC. LOAD SQUARE FEET OCC. LOAD TOTAL. SQUARE FEET TOTAL OCC. LOAD DEPARTMENTAL REVIEW "X" in box indicates which departments need to review the project. BUILDING - initial review 0 FIRE (I- 15-a1R ROUTED INIT: 5-) INrr: 4/96z INIT: UIREME DM.liKEO T CONSULTANT: Date Sent - Date Approved - FIRE PROTECTION: S • rinklers ■Detectors ■ N/A FIRE DEPT. LETTER DATED: INSPECTOR: ZONING: IBAR/LAND USE CONDITIONS? ( ]Yes REFERENCE FILE NOS.: MINIMUM SETBACKS: N- UTILITY PERMITS REQUIRED? s- Ad Yes ( No �o PUBLIC WORKS LETTER DATED: .3/4/901- jJ TYPE OF CONSTRUCTION: UBC EDITION (year): REVIEW COMPLETED PERMIT NO. CONTACTED DATE NOTIFIED Lam -`' 1Y\ l _ (� �� ll �� `Ic- t55 J (init.). DATE READY PERMIT EXPIRES 2nd NOTIFICATION BY: (init.) AMOUNT OWING (f) 3 5 0 so 3RD NOTIFICATION BY: (init.) CITY OF TUKWILA Department of Community Development - Building Division BUILDING PERMIT APPLICATION MAW Joumcenrer DOUI&VelfU, 1 uKwna vvn V0100 (206) 431 -3670 :)..∎ to t n DESCRIPTION A OUN RCPT LATE BUILDING PERMIT FEE op Q :' PLAN CHECK , t J 1� NUMBER l — L j i( :APPLICATION. MUST BE . • FILLED ..OUJT..:COiViPLETEL Y PLAN CHECK FEE 4 00 Me - Al` BUILDING SURCHARGE .'F,0 OTHER. TOTAL • t7 ' SITE ADDRESS SUITE # 15425 53rd Ave. S. Tuk ._iL_. VALUE OF CONSTRUCTION - $ $95,257.05 PROJECT NAME/TENANT ASSESSOR ACCOUNT # 115720- 0033 -30 TYPE 0 • New Building • Addition • Tenant Improvement (commercial) • Demolition (building) WORK: 0 Rack Stora•e 0 Reroof O Remodel residential !!!. Other•Exterior retaining wall insta DESCRIBE WORK TO BE DONE: ;sect a Crib -bin retaining wall (120 lin. ft. length, 15 ft. height) Replacing existing rockery BUILDING USE (office, warehouse, etc.) Office NATURE OF BUSINESSt;ro • . mana:ement com outer demonstration /showroom WILL THERE BE A CHANGE IN USE? ® No 0 Yes If Yes, new building requirements may need to be met. Please explain: SQUARE FOOTAGE - Building: 10,000 Tenant Space: 10,000 Area of Construction: behind buildin WILL THERE BE STORAGE OR USE OF FLAMMABLE, COMBUSTIBLE OR HAZARDOUS MATERIALS IN THE ':T D g No 0 Yes IF YES, EXPLAIN: Pii9PF1'itNW FRRof Op. Eng.'s [,Deal. 701 Pension Trust c/n First PHONE 383 -7111 ADDRESS Partners ltd. 1450 First Interstate Plaza, Tacoma, WA Z1P93402 CONTRACTOR Retaining Walls Northwest, Inc. PHONE 747 -0956 ADDRESS 1299 156th Ave. N.B. #150 Bellevue, WA ZIP 98007 WA. ST. CONTRACTOR'S LICENSE # RTT -AI - WN115OJ EXP. DATE 8 -29 -92 ARCHITECT PHONE ADDRESS ZIP HEREBY: CERTIFY THAT D:.H _... E TAUE.AND.CORRECT, 1ND 1 BUILDING OWNER SIGN UREj OR 1,, AUTHORIZED PRI T NAME Gregory Rich -- 40 EXAMINED Th. ORtZED .'Tt :APP.L' #.P.LICAT IG' °Fi'li DATE 10. (- zlicl) PHONE383 -7111 AGENT ADDRESS 1450 First Interstate Plaza CITY/ZIR'acoma, WA 98402 CONTACT PERSON Gregory Rich 1 se 5 �' i G> PHONE 383 -7111 I 1U`�4�,5(D APPLICATION SUBMITTAL In order to ensure that your application is accepted for plan review, please make sure to fill out the application completely and follow the plan submittal checklist on the reverse side of this form. Handouts are available at the BVI..I.IIa coL...er l,vhwh p. viluC m.'3iC uvtul.i.; .ii.vrCGuvn an iaj+p,..iu.wri Gifu jr.a.. cubmIttai icMu..uf.lv.l.u. Application and plans must be complete in order to be accepted for plan review. VALUATION OF CONSTRUCTION Valuation for new construction and addtions are calculated by the Department of Community Development prior to application submittal. Contact the Permit Coordinator at 431 -3670 prior to submitting application. In all cases, a valuation amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Building Division to comply with current fee schedules. BUILDING OWNER / AUTHORIZED AGENT If the applicant is other than the owner, registered architect/engineer, or contrac'or licensed by the State of Washington, a notarized letter from the properly owner authorizing the agent to submit this , permit application and obtain the permit will be required as part of this submittal. EXPIRATION OF PLAN REVIEW Applications for which no permit is issued within 180 days following the date of application shall expire by limitations. The building official may extend the time for action by the applicant for a period not exceeding 180 days upon written request by the applicant as defined in Section 304(d) of the Uniform Building Code (current edition). No application shall be extended more than once. if you have any questions about our process or plan submittal requirements, please contact the Department of Community Development Building Division at 431 -3670. DATE APPLICATION ACCEPTED Rs— I -R) DATE APPLICATION EXPIRES RECEIVED 11(:1- 2 2 1991 SUBMITTAL CHECKLIST • .SpeifIcadons.. • Struotural•Celcuiations stamped by.kWashlitgton.Stire ......... SoHs report stamped by a Washingte.n•Stete:ligerreed'enilrteer.:, E ...., „: ,...... ,.„.. ...„ •.ri Energy calculations stamped by a Washington State ilcenaod engineer or archttact [J Legal desciiption p.Wericing:drawings; stamped by a Washington State Iicensed ' pittrt • • . Structural drawlngs ' • •••‘"' • • ElevetiOns, * Landscape plan . . • ,,,...... oormit.apptlo4floo„.(ene,,..feC:entire.:pro,... SIx (6) Bets of civil drawings NOTE See utility permt applica silbmittir) • te4iireirrenta.• RACK STORAGE : I : ,;_;; • • .• Completed lounging permit application:,•:::::: Assessor Account Nunibor ................ * Existing and proposed par$dng ',.,',•:',■..f.rindiaaPe••0.1ar)• (if •Siiii)litiebie;•f.e:;:Changeof•Ota)",..::::::..... . . . .• .... :0yeraft . „.„ ••••••••••••••••••••''''''''''''''••••••••" • ••"•:'-'••• • •••••• • • • .• • • • jj j1) ... • • •••• '••••••• • building or sOtiaM.fOotage•-• •••••••••• s" • sPtioe'planliathi•Osi.p.of.each „... room ••••:,••••••.,„..Exit.doors, egteta! patterns.: ,..„ •••••••■ New wall* existing imtill,,and walls to be dernolishod;, : • •••••••:::::::*...orOst:stiCiltintitihaiVirig *jar constructton and mothod of . . . •••. . .....•••••-•••• •-••••• ••••••••••• • •••• —...•••••••-•••••• ..••••••........".•••••.••••••-•...•:--•...•••••••.-•-•• • • • •-•••••• .. . ... ....StruCteral:01CtitatiOnii stamped by Washington State Ucensed : : : : ••• . . . : • •• • .• . ... Comptetod .„, 1—Nartatilie.desCribingi•existingrpof,' material being rentOVed, . i . Prier:to firiei:Inspeodon'and • o if f „ • . • ,.....,.,..... . ,..:..•,•:••••••••••••••.• ..'"•'• • ••••••••••.: . .. .. .. ......,.....: Legal cles AssessorAg.:ount um.. ,. 644' TWOISets:(4)1•Ofyroriting •• • • : ••••••••• ••••••••••;•: ;••••'; ';';'•";•••:•••"•.;••:::•.:,F : : ".. ........ ........ 8 Floor plan 'Root plan Building eli■ratIor)s (alt views) Building,Cross-segOony. • ' I: • Structural framing plans.: • Site Plan :••••••—••;—•■•• K:kr plan,: show dossat hytkant • Foundation plan .• r.. Include acces:nrobuildat showins$9.:. • Floor plan WM • d • Roof plan , • • Building elevations (all views) • Building cross-section • Structural framing plans • . Washington State Energy Code data Completed utility permit application El Six (6) sets of site plans showing utilities NOTE: Building site plan and utility site plan may be combined. See • utifity permit application and checklist for specific submittal requirements. Additional topographical and soils information may be required if unique site conditions. NOTE: If any utility work Is to be done provide permit application and plena must be submitted. • . • ; . REFIOOFS . . . • • ECompleted building permit application (one for each structure) inAssessor Account Number • • . •: 1-1 Narrative describing existing roof, material being removed, and material being installed. • NOTE: A certification letter is required prior to final Inspection and sign- off of the permit. • I41005 11%18%91 16 :18 FAX 20(-383_ 7112 ,,,1ST uCA I�Tf1LLHNu 14u MU tuliowinu UU$'I Wsa prurnises situated within the County of Kind State of Washington / , and being That certain space (approximately 4300 sq. ft.) located on the east end of the building situated on the ground legally described as follows; That portion of the East 300 feet of Lot 3, Brookvale Garden Tracts, according to plat recorded in Volume 10 of Plats, page 47, in King County, Washington, lying North of the following described line: Commencing at the Vest quarter corner of Section 23, Township 23 North, Page 4 East, W.M., thence South 0.42'00" West a distance of 993.00 feet; thence South 88"12'00" East a distance of 642.00 feet; thence North 0"42100" E$st a distance of 184.20 feet to the true point of beginning of said lino; thence North 8812100" West a distance of 300 feet and the terminus of said 1 • WAC 197 -11 -970 MITIGATED DETERMINATION OF NONSIGNIFICANCE Description of Proposal A 15 -foot high Crib - Wall /Retaining Wall to replace.an existing Rockery. The poject would involve 400 cubic yards of cut and 400 cubic yards of import fill. Proponent First Capital Partners, LTD./ Gregory Rich Building Manager. Location of Proposal, including street address, if any 15425 53rd Avenue South. Lead Agency: City of Tukwila File No. EPIC -58 -91 ** See required Mitigation Measures Attached The lead agency for this proposal has determined that it does not have a probable significant adverse impact on the environment. An environmental impact statement (EIS) is not required under RCW 43.21C.030(2)(c). This decision was made after review of a completed environmental checklist and other information on file with the lead agency. This information is available to the public on request. (X There is no comment period for this DNS (J This DNS is issued under 197 -11- 340(2). Comments must be submitted by . The lead agency will . not act on this proposal for 15 days from the date below. ,Responsible Official Rick Beeler Position /Title Planning Director Phone 433 -1846 6200 Southcenter Boulevard, Tukwila,_ WA. 8188 Z. Signature_ Address You may appeal this determination to the City Clerk at City Hall, 6200 Southcenter Boulevard, Tukwila, WA 98188 no later than 10 days from the above date by written appeal stating the basis of the appeal for specific factual objections. You may be required to bear some of the expenses for an appeal. Copies of the procedures for SEPA appeals are available with the City Clerk and Planning Department. FM.ONS ` EPIC -58 -91 The Questar Center REQUIRED MITIGATION MEASURES A landscape plan shall be submitted to and approved by the Department of Community Development prior to the issuance of a building permit. Landscaping shall include the following: 1. Hydroseed 2. Ivy planted along the top of the proposed crib /retaining wall. • City of Tukwila 6200 Southcenter Boulevard • Tukwila, Washington 98188 John W. Rants, Mayor Plan Check #91 -464: Questar Building 15425 53 Av S THE FOLLOWING COMMENTS APPLY TO AND BECOME PART OF THE APPROVED PLANS UNDER TUKWILA BUILDING PERMIT NUMBER Lpq qz, 1. No changes will be made to the plans unless approved by the Engineer and the Tukwila Building Division. 2. All permits, inspection records, and approved plans shall be posted at the job site prior to the start of any construction. 3. Subgrade preparation including drainage, excavation, compaction, and fill requirements shall conform strictly with recommendations given in the soils report, and as specified in "Standard Specifications for Criblock ". The Geotechnical Engineer shall inspect subgrade prior to wall construction. A record of this inspection shall be made available to the Building Inspector upon call for final inspection approval. 4. All construction to be done in conformance with approved plans and requirements of the Uniform Building Code (1988 Edition). 5. Validity of Permit. The issuance of a permit or approval of plans, specifications and computations shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of this code or of any other ordinance of the jurisdiction. No permit presuming to give authority or violate or cancel the provisions of this code shall be valid. Phone: (206) 433.1800. • City Hall Fax (206) 433.1833 PLAN CHECK NUMBER ROUTING PROJECT N UTILITY PROJECT " TRACKING �HECKLIST SITE ADDRESS 1 SUITE NO. DATE PLANS RECEIVED TYPE OF REVIEW DATE ROUTED TO PWD DATE PLANS APPROVED DATE RESUB. REQUESTED COMMENTS DATE ISSUED Channelization /Striping /Signing Curb Cut/Access /Sidewalk Fire Loop /Hydrant Flood Zone Control PERMITS REQUIRED 'XI PERMITS PERMIT NUMBER APPROVED PLAN /LETTER DATE ISSUED Channelization /Striping /Signing Curb Cut/Access /Sidewalk Fire Loop /Hydrant Flood Zone Control X Grade /Fill eor Ad Fg, d G 61 ?-- 6 -72 4.7 - G%a2 Hauling fd 4.1 -qv Pit)f7 -va �3 44--k Landscape Irrigation 0 Moving an Oversized Load Sanitary Side Sewer Sewer Main Extension (private) Sewer Main Extension (public) Storm Drainage "1, fW 9� »u0 <v 3- 6 - ?.z- ,I 4 -7- 9.9 Water Main Extension (private) Water Main Extension (public) Water Meter (exempt) size: No.: a Deduct 0 Water Onk. Water Meter (permanent) size: No.: Water Meter (temporary) size: No.: Other: Other: CONDITIONS OF PERMIT ISSUANCE OR FINAL SIGN -OFF OF PROJECT 3ITY OF TUKWILA e ntra I Permit System - Engineering Division 7300 Southcen(er Blvd., Tukwila, WA 96188 'none: (206) 433-0179 )ROJECT:: . Site Address: NFORMATION Name of Project: 779.e- 729/2 UTILITY PERMIT APPLICATION PLAN CHECK NUMBER: rope rty Owner: 4W c 2J/v/a/1/0," 0/c', 's 70/ /e 7: Phone No.: ,?8.y 2//.1 CVO ,-/sr /04,4:7-4..ans ..47-40 • 3treet Engineer: City/State/Zip: Phone No.: Street Address: City/State/Zip: ntractor: _,W/.7* ="7-1/6 Street Address: Az?, : <ing County Assessor Account Number: /7.6-7,2.0 Channelization/Stripino/Sioning REQUESTEII.. 0 Curb Cut/Access/Sidewalk 0 Fire Loop/Hydr, (main to vauit) - No.: O Flood Zone Control kg) Land Attering 700 whiz: yards IS Hauling , o Landscape Irrigation o Moving an Oversized Load Sanitary Side Sewer No.: O Sewer Main Extension Private 0 Publi:: Phone No.: City/StateiZip: '7800 7 1.,t2/11 AS 0 i/J-,/ Ek Storm Drain O Street Use Sizes: 0 Water Main Extension Private 0 Publk; O Water Meter / Exempt: - No: Sizes' Deduct E Water Only 0 O Water Meter / Permanent - No.: Sizes' O Water Meter /Temporary:- No.: — Sizes •_ 4/0 4X Other: VIATE.R•:;:METERM:;; Name: P.,-7FUNi)!BILL'ING:i:::: Street Phone No.: City/State/Zip: MONTHLYi EILLINGS TO:. 0 Water Name: Street O Sewer 0 Metro 0 Standby Phone No.: City/State/Zip: ..11111••••■••■!■ DESCRtPTION OF PROJECT O Single-Family Residential O Multiple-Famil DetIin No. of Units: O Commercial/Industrial ' O Hotel O Mot& El Office O Retail 0 Duplex O Triplex O Warehouse O Manufacturing O Apartments O Condominiums • Church O Hospital O Other: 0 School/College/University O Other: New Building 0 Remodel/ Square footage of original building space: Square INFORMATION ' Addition Square footage of additional building space: Footage: King County Assessors valuation of existing structures: $ Valuation of work to be done: $ /00, 0. 00 1.HEREBY:CERTIFY7 ipoiRfFiEcno:. f".1 Applicant/Authorized Contact Person t.oent Sionajure: ('J/ Print Name: AnIS PlEiS (print name): Address: Date: -a q Phone: 87-4/ Date Application Accepted: /4,1O Phone: Date Application Expires: cmy NyCAALIN 12/31/91 PERMIT CENTER HAULING Permit No: PW92 -0063 Status: ISSUED Parcel No: 115720 -0033 Site Address: Location: 15425 53RD AVE S TUKWILA Start Time: Bond Number: End Time: Issue Date: 04/20/1992 Approval Letter: 03/06/1992 Expires: 06/19/1992 TENANT THE QUESTAR CENTER Phone: 206- 383 -7111 15425 53RS AV S , TUKWI,L "A` ,':WA`f.:' 98,:188; OWNER CAPITAL CONSULTANTS,AE:-:' 2300 SW 1ST AVE, ;;':.PORTLAND OR , 97201 CONTRACTOR RETAINING WALLS NORTHWEST;, INC. Phone: 206- 747 -0956 1299 156TH AVE N. E. #:150 ,',.:BELLEVUE , .WA ,,9800.7: CONTACT DENNIS ELLIS ` Y Phone 206 -747 -0956 RETAININ''> ,G'WALLS NORTHWEST 1299 156TH AV NE # 150 BELLEVUE WA ******** *** * * *'* * * * * * * * * ** * * * * * * * * * * ** **** ** * * *•k***•k** ** *•k * ***** *•k *•k *•kit ** ** Plan;,Check: :Fee: 10::0,0 Inspection Fee 15'.:00-/ 'tiff Other Fee: `i'`,1 , '� .00 ;r°: 1.T0TAL='FEES - :' ';, '25.00`, **********,'*********•*****************;****.***,******* * * * * * * * * * *'•k * * * * * ** * *•k * * * * ** The undersigned hereby applies for- `'permissi'on to perform hauling per attached map in accordance. `with the :following''., condi'ti'ons: �� 1- Flaggisng, signing and coning sh`a11, be in accordance with MUTCD for traffic control.; 2- Contractor shall provide c e'rt i fie d flagmen. for. traffic c.ontrol . . ,,, 3- Sweep o otherwi se clean •stre'ets,' ,to thel;satisfact i on of ,Public` Workt s each night jaround'haulingroute i(notflushing allowed) . 4- Notify+t;clity inspector befor^e, 412 :00,noon „on;.:�.friday preceding any weekend work. 5- Permi ts�,, s valid between the weekdays, hpurs "ot,..,7c "00, a.m. and,, 3 :30 .p: `m. only 6- Clean and remove debris from city catch- -bas i ns i nand aroun•cj hau l',i'ng routes. 7- Provide „a'dequafte; temporary access as .knot' 'to 'i=nterfere • with. other.'.veh i cl e movement,or cause trucks to travel over curbs'•' 8- All vehiczles must make complete stop prior to'enter; "ing public/'right -of -way. v '\ . 1 ;, 1. CERThFICATE;'OF INSURANCE ($1", 000, 000 $2 ,'O;QO }4, B ON D; `�' ROUTE01,AQ fi.. ,, 2. $ 2, 0 0 0;,Q,ON Q 3. ROUTE MAPS', �t' ri r_ -:*--1M THE APPLICANT MUST NOTIFY -. "THE .INSPECTOR' OF COMMENCEMENT' AND COMPLETION OF WORK AT LEAST HOURS IN ''ADVAN _ CE- 433- .0.1.79 Signature: _ Date: _J zo q� * * * * * * * * * * * * * * * * * * * * * * * * * * * * ** * * * * * * * * * * * * * * * * * * * * * * * * ** APPROVED FOR ISSUANCE BY: JAP Issued By: tli. af Authorized Permit Center Signature Date ************************************************ * * * * * * * * * * *•k * * * * * * * * * * * * * * *•k* I hereby certify that the permit holder whose name and address appears on this record has satisfactorily met the standards and conditions for the project approved herein. Final Inspection Approved By: Inspector Signature Date Permit No: Status: Project: Address: Location: Parcel #: Wetlands: Slopes: LAND ALTERING PW92 -0064 ISSUED QUESTAR CENTER 15425 53 AV S WEST SIDE OF PROPERTY 115720 -0033 0 Watercourse: 0 X TENANT THE QUESTAR CENT;E 15425 53RS A•V a rYTUKWILA ,,' ,'.. ?98,;1:8$ › -. OWNER CAPITAL COt U' TAN75 i�RE ,� , ,y u 2300 SW`'STTAVE , PCR ' LAAND 0�2 , , 9'7201 �A; h`` CONTRACTOR ° .a:�• '. 1 �„x ,;;..,:N �l ''' RETAIN:1 WALLS `NOR`i:HET " }INC ., ,. Rfioh.e • 206- 747 -0956 129 �Th6TH...AWE'».NI .`E. +�# 150 BELLEVU= f fWA•^ 9860 ** * ** k * * ** kk k• *'k*,* k�k* * & ** *yi'kalt•k, k k'�i, '#ilktilt k k k L'k;t"f ,ilk 'k1t k* WA.' Issued: 04 /07/1992 Approval Letter: 03/06/1992 Expires: 10/04/1992 Phone: 206 -383 -7111 ,. dv . -�, . k * *'k * * * *** ** ** sett ti3on Additional %3. { r RETAINING WALG, /FILL�•EXPORTA OAF; ?.LL � r Grad i ng /F i l����,�Yards)-Cut: , 4j�, •:4 i bd kw4. Perms t,i F ;fee. :Tnr: '',�b �:, g5,, -50 Plan C h e c�}F' e e:� 2I! 5 0 --... r r, fO,t'ih e r��.i'i y .!V ''J �,..4.•/ ,'N. , a: Total ;ees: v f r + fA^ •k * * ** * * *, * Sk' k* * * *(* *tk *. *':at ** *•k"'k.kc*aikk k * *, *'k ,k • * t143 **ct ****** * *'+h, *t, *ask *ikkak-.1� °:k * **k *k * *• 'r;T o t a 1, X700 Account No: '0017/,32`2.1tid0', Account No: �000/3'�45.. B3 Oi\ /'s'S'y Acc.o,unt No 000!'3L�6.9134:��, %r 10 40 '.;;' Via l,lj a tiro n : 100,0p0.00 '' I hereby c'1rtif (th'a �I - v _ fn v s, /f r C, , ..r^ ,,, r .. k', 'e �y. t h e�rea 11�and eI,amine•d tnJs permit ,and" ,now;;kthe same M to be trae and correct '` ALY,.p'ravW,9ns( oflFflarn -`�or d ordinances.go.vern'�i g this work wi 1 1 , ce icump 1 i ed withr,/wliert�h �� er �speo.if:•ie.d, he'r ein or not'. the �grarlt'.ing of this perm does not' pre''sume_,,.t'o..'g i ve aut,h'oe'j. t.y:1to ,,violate ;or ,!can`Ge 1 the provisions ft,arly oeber state or locaaws regurl•a•ting constr•u..et�� or' {Ir the performan eofwCir °;., I am authorized .o,rs;igrl, for ~ and obt,ain" thyis L {and Altering p rp� ii t ‘{Tlfi,i s Fpermi t shall becoi e ]fp ani1';ti i d. i'f ;theT- 'wor7J �`i s not commenced w1'1� in 1x30 days from the datf o of isuaric,e;`or cif tli "a "'work tis suspended o �; andoned f:or a period o f 1�'0 days • ronta t'Rie last ins'p`ection . t iw. \ i d.;�,j7'�,t ,+,r�fiYY A'b yjr.J vr1 THE APPLICANTS, UST NOM( THE CITY INSPECTOR OF COMCNCE.MENT AND G•OMPLETION OF WORK AT LEA Signature: 'k * * * *•k* * *k * *** APPROVED FOR Issued By: �24 MOORS IN ADVANCE. FOR AN I,jVSPECTIONCALL ,/4;3 =0179, Yd '� r * � � i =• ;;� iii• c'; ay A,: - ..Date. „c;.: %- �Z *** *k: *** * *k** *'k; * *ik 440, *k** * * ***kk'•k•' * **** *** *** * * **** SUANCE:`�` { -i '' Authori zed Permit C/ rYte1^ r15;.10a05.ie ********************• k*' k' k' k***-k*********' k' k************' k'k** * * * *'k * *'k* *'k ** ** * * * * *'k* I hereby certify that the permit holder whose name and address appears on this record has satisfactorily met the standards and conditions for this project approved herein. Final Inspection Approved By: Inspector Signature Date: ' STORM DRAINAGE Permit No: PW92 -0065 Status: ISSUED Project: QUESTAR CENTER Site Address: 15425 53 AV S Location: WEST PORTION OF PROPERTY Parcel #: 115720 -0033 Watercourse: 0 Wetlands:0 Slopes: X Sewer: N/A Water: N/A TENANT THE QUESTAR CENTER Phone: OWNER CAPITAL CONSULTAN,TS'.REM 2300 SW 1ST AVE.', `PORTLAND OR , 97201 CONTRACTOR RETAINING WALLS:-NORTHWEST' INC.; Phone 206 -747 -0956 1299 156TH 'AVE N. E'. # ;150 `, '.BELLEVUE , 'WA', , 98007`,;;,, * * * * * * * * * * * * * * * * ** **; * * ** * *k* * ** '. * *' * * * * * * * * * * * * ** , * ** ** *: *;�• * * * * * * ** * * * *,r *** ).Le Issued: 04/07/1992 Approval Letter: 03/06/1992 Expires: 10/04/1992 206 -383 -7111 Additional Permit'vDescript.ion• ,("r'' "�`° i72' "n' - RETAINING WALL" : %` Existing Squa,rle. Feet: New Square:Feet: Inspect';i'on F`ee: '15.00 J "- • Plan C �le'dk Fee i _• y '-'"'1:0•..00% II: TOTAL FEES. = 425.00.. 's ft i;, l u t on . ' s N Value-of . Construction: 100, 000.00 King County,Va a i • ' �- ************:******.********._***********.*****.**.***** k** * * * * * * * * * * * * * * *. * * * * * * * * * * * * ** I hereby accept this permit and agree to `abide all applicable sections of the City of Tukwila Municipal Code..' We agree. that the ,City of Tukwila shall be held harmless or of all or any claims erisingas'a' result of this project. Permits which have. ` l apsed beyond the exp i''r-a.t i on_..date 'sha 1 1: ' re`qui re a ,: y..:r reapplication and�re,issuance of the perm:i't ;,through 'the City .a�tfan additional fee. z`.:, ;h, I 1.1 '., �; ;,,, l 4 ^�•' , •, S"4 Ie lj 't 4 •. yr. THE APPLICANT:'.MUST NOTIFYTHE CITY INSPECTOR•:OF..COMMENCEMENT AND,,COMPLETION OF WORK AT LEAST 24 HOURS IN,.ADVANCE.� TO SCHEDULE -`AN INSPECTIONf'i'CALL 433 -0179. \'-'' r ;, e ›�, Additional - '.Square Feet :, Acct' Na:.; 4,12, 3.4`2.400 Acct,No /000 /34'5 {.830 Signature. Title: Date: 1/1 `, _ Company: &'2It..LhII0411 **************************;****** * * * * * * * * * * * * * * * * * * *. * * ** * * * * * * * * * * * * * * * * * * * ** APPROVED F, R ISSUANCE _BY:''' Issued By: Date: Authorized Permit * * * * * * * * * * * * * * * * * * * * * * * * * * ** enter Signature ****************** * * * * * * * * * * * * * * * * * * * * * * * * * * * * * ** I hereby certify that the permit holder whose name and address appears on this record has satisfactorily met the standards and conditions for the project approved herein. Final Inspection Approved: INSPECTOR SIGNATURE DATE *************** * * **** * * * **** *** **** ****** * * *** *fie * *** *•** ** *h* **** CITY,OF .TUKWILAI WA TRANSMIT k * * ** *'**** * ** *.******** k********* * *k * ** ** * * *** ** *k * * * * ** * * ** ** ** TRANSMIT..Number: 32000202 Amount: 25.00 04/07/92 10:42 fermit No: PW92• -00(3 Type: PW -MAUL HAULING Parcel 4No: 115720 -0033 °`Site Address: 15425 53 AV 5 Payment Method: CHECK Notation: RETAING WALL NW Iriit: DLM ******.*****•*************.********* * * ** ** * * * * * * * * ** * *** * * * ** * * * * ** Account Code Description Paid 000/345.2330 PLAN CHECK— UTILITY 10.00 000/342.400 INSP FEE - UTILITY 15.00 Total (This Payment): 25.00 Total Fees: Total•All Payments: Balance: 25.00 25.00 .00 !±Y **.******************************* ***** *A***A***k** **k******* *k** CITY OF TUKWILA, WA TRANSMIT ****************** h**** k******* k* * * * * * * *k * * * *Ah * * * * * ** * * * * * * * * ** TRANSMIT Number: 92000281 Amount: 108.00 04/07/9,10:41 Permit No: IW92•-0064 Type: PW-LA LAND ALTERING PERMIT Parcel No: 115720-0033 Site Address: 15425 53 AU S Location: WEST SIDE OF. PROPERTY Payment Method: CHECK Notation: RETAXNG WALL NW Init: DLM• ** ******************************* * * * * * * * * * * * * * * ** * * * * * * * * * * * * * ** Account Code 000/322.100 000/345.830 Description Paid BUILDING - NDNRES 85.50 PLAN CHECK - NUNRE$ 22.50 Total (This Payment): 108.00 Total Fees: Total All Payments: Balance: 108.00 108.00 .00 ', A. if**+***+* **A.***** ********+**++** it* *a if +* *+***++**** **+*Alt ******* -CITY OF TUKW%LA NA ' � . TRANSMIT . � +��******��**********+**********A************************�**** * :TRANSMIT :Number: 92000283 Amount: 25"00 04/07/92 10:43 +* Permjt No PN92_0865 Type PW-SD STORM DRAINAGE :� ^� 'Parcel No: 115720-0033 ,:-':','Site Address: 15425 53 AV S , � !`�' ^ Location: WEST PORTION OF PROPERTY `.'' 'yment Nethodx CHECK Notation: RE.A%NG _.ALL- NW %n1t: ^DLM '******+*a******a************+********'*************.****+****** Account Codo Description Paid 000/345.830 PLAN CHECK UTILITY _ - 1�~O0 '' 412/342.400 INSP FEE - STORM DRAIN 15°00 ' Total (This Payment): 25.00 Total Fees: Total All Payments: Balance: 3L r‘. 35.00 25.00 .00 -_` *** kkkkh***** hh* k********** h****** ****4***k***h•k*4*kk*A*******k* CITY OF TUKWILA, WA 1'RANSMII' +4 ***k***** *** ***4** h* 4 k** JF*** *** *** **k * * * ***** ****44**** **k* ** TRANSMIT Numbers 92001468 Amount: 2.00 12/29/1 /2dfj�'c 17 Permit No: 6952 Type HISTORY HISTORY PERMITS Location: OUESTAR CENTER Payment Method: CASH Notation: (UESTA1 CENTER Inits SAO ***** A * * * * * * *** **4 * ** * * ** * *4 * * * * * * ** *Ark * * * * *4* * *4* * * * * * * * * ** * * ** Account Code 000/341.600 Description COPIES /PRINTING /WP Total (This Payment); Total Fees: Total All Payments: Balance: 2.00 2.00 .00 Paid 2.00 2.00 GENERA TOTAL CASH CHANGE 6387A000 2.00 2.00 2.00 0.00 16 :03 PRODUCER EMERY & KARRIGAN, 9780 SW, Shady Lane Portland, OR 97223-5479 INSURED Retaining Walls Northwest, Inc. . 128O166th Ave. NE#U5O BoUmmo.VYA 08004 INC. , THIS CERTIFICATE IS ISSUED AS A MATTER OF INFORMATION ONLY AND CONFERS NO RIGHTS UPON THE CERTIFICATE HOLDER. THIS CERTIFICATE DOES NOT AMEND, EXTEND OR ALTER THE COVERAGE AFFORDED BY THE POLICIES BELOW. COMPANIES AFFORDING COMPANY LETTER A West American !no ' Co. COMPANY r, u//"« - LETTER " ooumuY LETTER " xoumwY ^ COVERAGE - _ .--_ --- `"^~ — :::;;:::11::t::LTR CO um THIS IS TO CERTIFY THAT THE INDICATED NOTWITHSTANDING CERTIFICAYE MAY BE ISSUED EXCLUSIONS AND CONDITIONS TYPE POLICIES OF INSURANCE LISTED ANY REOUIREMENT, TERM OR OR MAY PERTAIN THE INSURANCE OF SUCH POLICIES. LIMITS SHOWN POLICY NUMBER BELOW CONDITION AFFORDED MAY HAVE BEEN ISSUED OF ANY CONTRACT BY THE POLICIES HAVE BEEN REDUCED «u EFFECTIVE DAm(MwmonY) TO THE INSURED NAMED OR OTHER DOCUMENT DESCRIBED HEREIN BY PAID CLAIMS. POLICY EXPIRATION DAm(MmmDNY) ABOVE FOR THE POLICY PERIOD WITH RESPECT TO WHICH THIS IS SUBJECT TO ALL THE TERMS, LIMITS A .AmX GENERAL �4 m «—m~w'nxuoowm^CTonxmor LIABILITY —ooww EnomLueEpmLuAmun 1xm/mouxoE � X 50 150488 03/15/91 03/15/92 GENERAL AGGREGATE m000mu'xow,mp«uox. PERSONAL & Aov.mmxv EACH OCCURRENCE FIRE DAMAGE (Any one fire) MED. EXPENSE (Any one percon) : 8/000.000 5 2/000.000 5 1,000/000 $ 1,000/000 5 50,000 v 5.000 A AUTOMOBILE X X °' LIABILITY ANY AUTO Alt. OWNED AUTOS m SCHEDULED HIRED AUTOS w��wxmxoma GARAGE LIABILITY } . � 50 15 04 39 03/15/81 03/15/82 COMBINED umcus BODILY NJom V�,,=mm BODILY INJURY (�,**mmm) PROPERTY DAMAGE $ 1,000,000 ` « « EXCESS LIABILITY UMBRELLA FORM OTHER THAN UMBRELLA FORM EACH OCCURENC AGGREGATE INIEWSOBENER v 5 Ifildnifien WORKER'S COMPENSATION AND EMPLOYERS' I STATUTORY LIMITS EACH ACCIDENT DISEASE-POLICY LIMIT DISEASE-EACH EMPLOYEE ViV.:MIti;Iiii;:;1011';:;:kiiiiiiitIiiiii: i $ |� $ OTHER DESCRIPTION OF ITEMS RE: OPERATIONS OFTHE NAMED INSURED CITY OF TUKWILA 6300 S. CENTER BLVD. SUITE 100 SHOULD ANY OF THE ABOVE DESCRIBED POLICIES BE CANCELLED BEFORE THE EXPIRATION DATE THEREOF, THE ISSUING COMPANY WILL ENDEAVOR TO MAIL _IIL. DAYS WRITTEN NOTICE TO THE CERTIFICATE HOLDER NAMED TO THE LEFT, BUT FAILURE TO MAIL SUCH NOTICE SHALL IMPOSE NO OBLIGATION OR LIABILITY OF ANY KIND UPON THE COMPANY, ITS AGENTS OR REPRESENTATIVES. ii1.4 AUTHORIZED REPRESENTATIVE . ' ' r- FF-:'.- 08 -193G 13:14 FROM REDMOND GENERAL INS. .... .. .. •. ..,•f•: :—!, • e.•we; .: n: .rn,,.x..:aq.:.....N...F•; ^;'.; .... ...•:...., I' 1i1:�1:+ .ij ..;..: �. .. 1, .;a .. .i.1 ,.,• ' ..,.:ex�,�N.r:i:.i.:l: %',�h'••i 0•Ipi1M,M•1dlFl.jf: .. ..... t 1 ye:1'r■, ' 1 I M1 1. .:.n• 1 ,:. ■��,,7,�N� ) ■ /OI „t,' ..' Alp RD. iiiiti�.Y•: � i11i.�. W „...,. r :, •t•N•JI •;•.:.I :i... •1:••!.ii. F111::.:1 y.t••v y•1•:.y:..1.n• ::,.,, I•• , r 1•r..t . • • tl, Itl.;. i,,, • • dM1d•• 1.. 1..: en• V• . II• I•. t.. A• INI •y•l,.t•.1•.••Fq..Inl•.•,Rt:t 1..:•q.,.t•rY.h..'..;..hl ♦.,n� rh •F, .. ::n �.r�••.•• rr: �:..rt::t . . 1....... M1..• r.... �..,,..•..•..•. .,..,..,...•.r.:..,....�...i.,. .. r... ...r..:... n.l,..l. :.:, -0.• ::.:•. PROOUOEA REDMOND GENERAL INS & SMITH MARTIN LEWIS INC P 0 BOX 847 REDMOND WA 98073 ' ROMEO NELSON L LAYMAN JR TRUCKING & EXCAVATING XNC 34930 NE 14TH CARNATION WA 98014 � n.rr.'rxLw- Jwn•:.- A:AA.x'1 tJt►wt a :..t..v: 1,tA•n. ten.. n,• nn.•nwntJl.F•Irn:;.nWJF•p't" .f :N .[Y•:: ..x. ,r.):.)t•1: :t.:l:f:ff`.:rt: Till: !i l•:J.1Fw.x.N.•......... :I .1 ,A:It iti;l%;W; ..•II<e:l ivn ta�N•MUhx�il•::,i1nAtYA:• 19 ;,!. �11.....t,,.t.N.x.x•fF.:.1Fr, 1.., 108UE DAZE /JAI', . iiei.o �:i...:.i..i �i:iiaiiiii.IM�i�. i:iv :iii ii ilii '.,r ••• , y n ,r IN.N•NtrtM••1 •x•rt••fF /tM rN....... ., 1 •. t•I.Ilnln .:�L:.I:,.: I:w.n.tl:,x;n 1 .. Npf•MMOyIwUxyt I ( '•.il r..l:p ;.: ... .. .•.., .:...: .1.. • n.{..f: 11�:..11.r:•rw..l.w.l•.11.,1 1 1.. 1,• w• xN. IF'• .V.Nir;nl•�t��lt{IN:rI•i:..;r:r . ..•. C;1i 1, v. p141A+DDiYY) 4 08 92 THIS CERTIFICATE IS ISSUED AS A MATTER OF INFORMATION ONLY AND CONFERS NO RIGHTS UPON THE CERTIFICATE HOLDER. THIS CERTIFICATE DDOES NOT AM AMEND. EXTEND OR AR THE COVERAGE AFFORDED BY THE W. COMPANIES AFFORDING COVERAGE CoMPANY A p C N A COMPANY n. so R C N A COMPANY C LETTER : COMPANY D izrrEst i. s COMPANy E 9- ,L6 A'�y %JI ;Ii1M•;••11;1'• �•�n•n.., n,n'•1� r' wy:N:x: 1:IM�'/i:.:Ir'.I::al IN If�Y:; ,. kN:N♦ All. MV4 ;a:rit. •I.1. AF11: tAA:N•I••M A.ttItAP. 'N•YlJ:xir1Al�Yi:•ti•9,:x Iyl.t.:A:l� 4•M t/,• lV1 I'll t1•gfJ: �,�A/,��r� ,1JG�7.;1: .I.x�N,.tJ. 1�.1.t111./�1�: *.11 1< •JI y�{1!Ir1..11N, ,f<..11: , x.A• M I M M:rt:1x l:/•x•J 1%11) p l ,f�i�:! Ir�.p ` `IN�x�.11, ,' 0••t•.fll 1 ;. .l .x.IFf:• ►!v . .56. : ,.... x gl.Ai• U,, ,,J 1n:xtN; P :oNIN.YnhN. i;!..bAAM A•N l,l .p , ..,yNIyM Ir p'IjiA,' :j►litti :pi.t.Nr.tiSji:r:A;i Nly, r!y t f.,:i:F rgl n..�a t:rN iirfr:iroxg.; i..:lt.•r:.r •..., n n ......... M... i.. ���:' li..[. �: C��K' xrP' �1.' �. Yn..•. w., �...•. YwwYI. aL�.• n.. Y.,•.,..,.. Y.,. r4' �fJA• IV' ii• I: q. Yh. lo.:.•:.. N.. N• x. xw1. N. I. x.xJrixltr,TW'NWM•xA1CN•NM�:AWA �:! M Atix ��l;yA!:IY✓<:NIYI,I:Ax A1,11NP °f kxiMil.'N R'i17iwN�Y•w(IN rr!{ Tics IS 't0 OERT1FY THAT THE POLICIES OF INSURANCE USTED BELOW HAVE BEEN ISSUED TO ThE INSURED NAMED ABOVE FOB THE POUCY PERIOD INDICATED. NOTWITHSTANDING ANY REQUIREMENT. TERM OR CONDITION OF ANY CONTRACT OR OTHER DOCUMENT WITH RESPECT TO WHICH THIS CERTIFICATE MAY BE ISSUED OR MAY PERTAIN, THE INSURANCE AFFORDED BY THE POUCIES DESCRIBED HEREIN IS SUBJECT TO ALL THE TERMS, EXCLUSIONS AND CONDRiON8 OF SUCH POUCIES. UMrrS SHOWN MAY HAVE BEEN REDUCED BY PAID CLAIMS. `POIJCY EFFECTIVE I POL3CY EXWRATION i • co TA : TYPE OF INSURANCE FOUOV Ta1MsTI ; DATI pAMbDm7 ; oATE savoorm ; UM'S & i OENEIURLLL*YNIW i X i COMMERCIAL OCHERAL UABILIrY ',I'll', I C4AUS MADE' X I must I ; OWNER'S A coNTRACTOR'S PROT. 1 ; 807702463 , 7/16/91 i 7/16/92 IoNF.AALAGOREOATE ;$1,000,000 I I 1 PIWDUCTB.cOMP/OP AoG, I $1 I 0 00 1 0 0 0 «PERaoN& 4, ADV. INJURY :$3.10001000 ; I ; ■ EACH OCCURRENce ' $1 1 0 00 / 0 0 0 1 I t' I FIRE DAMAGE y urw its) ! 45 0, 0 00 I l i WIC, maw siy on. MK+oN 1 4 5 0 0 0 8 `AXJTOMOWLE u48ur v 1 300574747 7/ 16 / 91 L7/16/92 I� o a�Npt>: ; 1 ; I i I` 1 ALL CWNW AuTOa I 1 JOWLY INJURY 1 X ! SCAM= AUTOS I I (PH pHs ll X ;HIRED AUTDB I ; , 9004.Y *WRY X ; NON-OWNED AUTOS I I Ioo14K+0 I I I GARAGE LIABILIT , I I PRoPER TY DAMAGE 11 000,, 000 j S 1$ 1 I EXCUS L1AbLTtY I I i i EACI1 OCd►RRPlJOB ; j ■ i 1 Lwow: LA PQRM i i I I A:oGREGATE 1$ I • mica THAN UMBRELLA FORM I .Ty , rt,A' ' k^it ri ”, �'{1{{{{'{ ram e.rintti"r "�i ;�;"'.s;+ ?. 1 N t .M •1 .AI.1: IA .1;'( YIN IWN. NN 11x, II NT... T111 yWWIrl•r• • WORKER'S V,VI.IPMVAI /N. 1 GrAIVroRt LIMIIY I1&...1.Yq(•1.NxMY�I �1••;1•,•i .. •;Ir., .1 N• N MV:t.•111•Ixl j I I 11� �/A�/� I,X Titre ..Z...8V.6:Y1r..!!II•SN111Mt AND 1 I I I EACH ACceO / F./APLOMB' UAOE TY 1 DISEASE -POLICY UMR I S ! I i 10 E -CA014 CM't.OYEE i$ ■ I i ; I 1 DESCRIPTION OP OPERAMN:AACA Mimi RE: QUESTAR CERTIFICATE HOLDER IS ADDED AS ADDITIONAL INSURED AS RESPECTS THEIR INTEREST IN WORK PERFORMED BY THE NAMED INSURED }��'�'y� • 4n��j. AA.. 1 'Y �i/ IA' AA11N:wiM1Y. :I:N1 }II IIIN�• II�fYY1 .1►:�Y: /h11•Itl.l'•Iil.l•AI•M 1:' .9k,.lN, 1GTt; :1•N NIN .,:g:x:NINAtllxlx.M wA.A:NIA0.1i., /t:.?;I: 111;101 NY J,Y•IINI;IwAt•I ........................ i...... �....... r.... �....;, rr. r.. Y.. r., Y.,... r....,.,. r. e....• F,, r... ...r.,..Y.Y... :r.,...r.....l..r CITY OF TUKW LA ATTN: aOHN PIEROG TUEIWILA WA 98188 } ...w..,r,;w........,..rr.....,. w..wn. ..w.•+,.n ,[t,:c��(p. Yi5 /'p. /o • ,:i�tiitN-MA. :M:�i4 Y��AiVAI wlt vAwlMl.tll.1•.i, u.' x•.. Y ItNJF,I•N•MVIIIIY•%J111r1•IF.WI I.VV' {l�•'.i.JVM� •,/-V •:x W ,1•• ! ^VMIIt4h• •111.11 /1"II.VII•AJrI.N 1.: I.N911.1..,r1✓.�y...Sh�•I.yl,�i y • UA.Iltlt ►YfA 1:1111/1►YtN IIxN V.hl•Ilil'Y,..It1•)I ` x:A:l1•N1)IIiYN INl,111�II.r�ltt•1yY11..:It:1;11� •yyI �t C.W„„. ,..„, .,t 11 ►1•I,VFIF4•IIV :,YIM;AIAMtY111 WIAW, Vl:► Iw: 1•: ItIIINININ.,1 1.1 4. .A YJ.........•. �...•,....,....., r....... r, ��r..( rtYA•". 1). i�' tr>'•.. �t..!.... r., �. r....•. i.. Y, Y.. M., Y. �s....... Y. Yr,.. r,,., k......... �......... u SHOULD ANY Or THE ABOVE DESORIBI:D POLICIES BE CANCELLED et EXPIRATION DATE THEREOF, THE ISSUING COMPANY WILL MAIL I0 DAYS WRITTEN NOTICE TO THE CERTIFICATE HOLDER {Ijll I x •1'1•/:N:1A'1 :rtii; I�NrM••III�IIt N. r1l• 11' AIr111NIt11 (Alai.1At:lA:a,.1:11tN: .Y.Y.......r......vs...,...,... BEFORE me ENDEAVOR TO NAMED TO THE NO oBUGATION OR REP - - ATTVES. "''I w LEFT, BUT FAILURE TO MAIL SUCH NoTIC@ sHtALL IMPOSE 7;1 UABIUTY OF ANY KIND UPON THE COMPANY, = GENTS OR .IA i •BH AUTHORIZED IW.PRESE TATIVE f f iii . 'tl' KEITH W BREWS CPCU ihJ I ,�►�l.. O ,I �1 ,. ;;;;;ffEit '7 6... i1, E0,7' iMN: YMliii yr.pdt.y.4 % ►iMMM7iiyiiiA:/kA rd OJI. '��•ty�� y^1'r'yyyy� •y{�����yyyYYY.y1N1�wn 'y�//y1�.� 7 gyp p(w•tl 1/.I,NIIt,Ji! Y t �I1V.V i•r��'MM.I.t2.x Jl.tl I ..I.WY•,WMI•N.N . xJ•JArIH AJYI .N•I,��V.H,�Y..•VV�.!�,lV,R.� �.1.V.D- .FRO 1 :CBIC SEA 2 TO: EMERY -KARR MAR 20, 1992 3:49PM 14944 P.02 CBIC CONTRACTORS BONfhNO AND INSURANCE COMPANY LICENSE OR PERMIT BOND KNOW ALL MEN l'SY THESE PRESENTS, that we Home Office: 1213 Valley Street, PA. Box 9271 Seattle, WA 981090171 (206)622.703. (800) 552.7264 (2A6)3624613 PAX National WATS: (800)426.9949 BOND NUMBER 705461 RETAINING WALLS NORTHWEST, INC. 1 6th Ave. N.E. #156 Bellevue Washin•ton 98007 as principal, and the CONTRACTOR'S BONDING AND INSURANCE COMPANY with its principal office in Seattle, Washington , as Surety, are held and firmly bound unto CITY OF TUKWILA, 6300 Southcenter Blvd., Suite #100, Tukwila, Washington 98188 hereinafter called Obliges, in the penal sum of Two Thousand and no /100ths dollars, for the payment of which well and tmly to be made we do hereby bind ourselves, our heirs, executors, administrators, successors and assigns, jointly and severally, firmly by these presents. 2,000.00 SIONED AND SEALED THE 23 rd DAY OF March 19 92 WHEREAS, the said Obligee has granted or is about to grant to the said Principal a License or Permit to engage in the businessof Erectin• a Crib -bin retaining wall, replacing existing rockery, 15425 53rd Ave.,S. Tukwila, WA NOW THEREFORE, if the said Principal shall indemnify the Obligee against any loss directly arising by reason of the failure to comply with the laws and ordinances governing the business of Erecting a Crib -bin retaining: wall in said City of Tukwila, Washington then this obligation shall be void, otherwise to be and remain in hill force and effect. REGARDLESS of the length of time this bond shall continue to be in effect, the aggregate liability of the Surety hereunder shall in no event exceed the amount of the bond. PROVIDED, IHOWEVER, that the Surety shall have the right to terminate its liability hereunder by serving written notice upon the Obligee ten (10) days in advance of its intention to do so. TERM OF FOND: March 23 , RETAINING WALLS NORTHWEST, INC. 09 92 •ip March 23, ,19 93 . PRCWCIPAL BY: SIGNATURE CONTRACTOR'S BONDING AND INSURANCE COMPANY BY: SURETY ATTORNEY-IN-FACT , • Gail Custer fl.4 OPa0l- WAW,2069 ... LiM • fTED POWER OF ATTORNEY READ CAREFULL7 . ..:... :. .. .:. cONtRACTORS8ONDitiel AND INSURANCE COMPANYISRE9PONSIBLE ONLY. FORi' HE. BONDDESCAiBED AND UP .TO. THE •AMOUKTSE 10RT 1IN•THIB;,: •' .LNMIfTED POWER OF ATTORNEY: ANY ERASURE WILL 1/01S THIS POWER OF, ATTORNEY IF YOU ,HAVE ANY QUESTIONSABOUi :OR K'ANTTO VERIFY THIS. • ':: ' `• ' : ;POWER OF ATTORNEY CALL CONTRACTORS :BONDLYG AND INSURANCE CiGNPANYTOf a:F)TEEAT'1(800)76i,2242 ...: •'• •'.. • • • . • Pertal.5tin i•• t ..: 4.2.i.:410:0:; :041 :: • : • •.: Attortey No;: O R 0 0:9: : ••3ppwer NQ -VA•0 4 4.3:. .. :: : ••••g;)hd Na:' :.7::p :5:4 6'I ' .: •:: •..: • ••• Lieiiteid Oower'i Atlernev Expires,' : • . • : :. 6 / 2 3 / 9.2 .: ' • •• • :: Dotc•Approved :: • : • : 3 / 2 3 /9 2 .: • roved bY: • • • ....... r— y� -�.L`- • .. ;.: i':: I>tmealPrincipel: ETA: 4`NING. :W A3, S% RO�tTHGiE.S'1; .IIIC ''NimeotoWipe6 :`C•1•TY'•O• •- •;TUKW' :ILA`. ; :.;.: • : :.. ,. .. .: • . . :;.fJdaatipHori(e� : :: 2 ; 0:4 0 ENS E: AND .P.E•RM I T': :•BOND .. •...... :..;, :' :. :' : : :....: :. :., : : : :• :s .: • :: •.., :< : :.' :.; KNOW ALL hEN BYTHE SEPRESENTSthatCONTRACTCRSBON CING AID INSURANCE COMM NY,acaporetiandulyoryun ®d and existirq up:tattle laws of the Stdo Weshinran, and tering its prircipal office in Sae* tang CournKWmhitx�on, dasbythnapreawto make, cornttYtte and appdnt GAIL CUSTER 01 PORTLAND , OR Ya true end Intel dtamepin4sct. With tul polder and authority hereby conferred in b name, place and stead, to execute, adnorledge and deliver the bordlsl described above: end to bind the Company thereby en fully end tomosearoanontnieechsuchbondwee,at gndtrytMPMWert, weldwithte corporateaeeidtheCo mpenyanddulye: mradbyhSbaarey; herebyretryingaralconrrn ,gehthattheseal rttornoy+ntoct = ydsinthepreminm, Sudappointmentis madeunderendbyauthaityofthefdloningresolutiones000fedbyOwE end c( Diect000fCONTRACfOR SSBOADAGAPDINSURANCECONI4WYon 6/ 0 6 / 9.0 mecum dud the Rwidendbsurhoriesdto appoints ehomey- Waudti4Company GA 1 L CUSTER with power end eutfrorityto sign on NNW atilt* Comoeny thole miealleneoue .tianaeendpaint tows which moyfromlirnotam be approved by Eked Roberti and Cindy Elfin, in etch penal sums and mending to ouch conotiono ao may M approved byBred Roberts and CindyGriffin. RESOLVED FURTHER that each Power of Attorney must set forth the specific description of the bond to which it applies, the eerie of the principal, the name of the obligee. the penal sum, the bond number. the Identifying number of the attorney- Indact.the Identifying number of the Power of Attorney. and the, name end signature of Bred Roberta and Cindy Griffin; end may vet forth the description and amount of additional reinsurence or collateral, if any. RBSOt.V® FURTHER that Brad Roberts and Cindy Griffin are authorised to establish a apecifia expiration date for the Power of Attorney end to modify that date from time to throe es Bred Roberts and Cindy Griffin deems necessary in hisiharsol. discretion; the'ppliabia expiration data to be clearly set fortn in any written Power of Attorney. RESOLVED FURTHER that. except es ettierwiae provided in the immediately succeeding resolution, under no circumstance. mall the penal sum tor any bond exceed E10C,000. RESOLVED FURTHER the above namedAttomey.inded is granted power and authority to exceed the applicable penal limits set forth in the immediately preceding resolution fur any bond In an amount equal to the amount of any additional reinsurance or of any chh, letter of credit or other security received as collateral security by the Company as inducement to issue thobond, so long as the description and amount of additional reinsurance or collateral are oat forth in the Power of Attorney, RESOLVED FURTHER that the authority of th. Secretary of the Company to entity the authenticity and effectiveness of the foregoing resolutions in any Limited Rawer of Attorney la hereby delegated to the following persons, the signsture of any of the fallowing to bind the Conpany with respect to the authenticity end etfectiveneas of the foregoing resolutions as if signed by the Secretary of the Compeer Brad Roberts and Cindy Griffin. RESOLVED FURTHER thet the signatures (including certification that the Power of Attorney Is still In force Ind effect) of Bred Roberta, Cindy Griffin and Notary Public. and the corporate and Notary -seas appearing on any Limited Parer of Attorney coataindog this and the foregoing resolutions may be by facsimile. RIMMED FURTHER that all resolutions adopted priar to today appointing the above named as attorney -In-act for the Company errs hereby superseded. IN WiTNEMI WHE ' crpaCTORS BONDING AND INSURANCE COMPANY ha. caused these presents to be signed by Bred Roberta and Cindy Griffin end its corporate na1 to be hereto affixed O•Vh!! y �vM�M� CONTRACTOBt tHG. ,`p INSURANCE COMPANY } SEAL • y • f, � CI dyGritfin By: Brad Roberts .4d11//141.9i- 410 STATE OF WASHINGTON — COUNTY OF KING On 6 / 0 6 / 9 0 ,personalty oppeared BRAD ROBERTS and CINDY GRIFFIN, to me knorm to be the representatives of the corporelion that executed the foregoing Limited Power of Attorney and acknowledged acid Limited Power at Attorney to be the tree and rotatory act and dodo} said corporation, for the uaee and purposes therein menlioned, and on oath amid that they are authored to execute tea said tin td Power of Allem.* K oig IN WITNESS WHEREOFIha ve hereuntosMmyhandandaffixed myofficia eali.f.rdigars11431Nit '. r92 44;:o The undersigned, wing under seniority of the Bard of Directors of CONTRACT e ' e INSURANCE COMPANY, hereby certifies, as or in lieu of Certificate of the Socretery of CONTRACTORS BONDNG AND INSURANCE COMPANY that the above and forgoing is a full, Inc. end correct copy of the Original Pourer of Attorney issued by said Company, and does hereby further artily i1M the said Pouwr of Attorney's still in fora end effect. Notary Prbllc In and for the Sate of Washington, residing atSeetda GNEN ender my hand, at S e at t 1 e WA this 23 dayof MAR 1992. 1.1)%1500) INSPECTION RECORD Retain a copy with permit INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206) 431 -3670 Project: c.0C Type of Inspect n: /—;,),,‘„? Address: /6— Y:7-5 '--s- Ae� Date Called: Special Instructions: • Date Wanted:3 _ e 7� a p. Requester: Phone No.: Approved per applicable codes. COMMENTS: ❑ Corrections required prior to approval. Inspector: Date: ?4 ❑ x.00 REINSPECTION FEE REQUIRED. Prior to reinspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. ecept No.: i INSPECTION RECORD Cr Retain a copy with permit CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 952 PERMIT NO. (206) 431 -3670 ro act: , LP Ca4 A f'pe o nspe M R O /.,. ,4. 6) Address: lam. L(2 C7—S4 1 Date Called: Special Instructions: Date Wanted: 3''.6"' yi am.�i.m Requester: Phone No,: Approved per applicable codes. ❑ Corrections required prior to approval. COMMENTS: Lector: ❑ $30.00 REINS I CTION FEE REQUIRED. Prior to reinspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Date: C INSPECTION RECORD Retain a copy with permit CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 • .:. ype o nspect • n. ,W, 77 / • r: : v 1: Special nstructions: Date Wanted; `— 9 am p.m., Requester: ' `% Phone No,: F _ ❑ Approved per applicable codes. COMMENTS: • Corrections required prior td`'approvai. 2-) la t /L-72-ct ( fr--/-7At ye, /L A l%,J 770 SA" Zl- 6 0'' r, c1° -7 �� fr'a 4:7 `Z,� 46 / "5447, 3) ,?-' . le //et, � <« /z -4f;---eo ee,:a 4 /-",,,asy O ' Date: j ❑ $30.00 REINSPECTION FEE REQUIRED. Prior to reinspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. j Receipt No S CTi4N N0. INSPECTION RECORD Retain a copy with permit CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (vgSc PERMIT NO. (206) 431 -3670 ro , qU.v�- -k•C�r C.Q►�� =ev ons fo 0 UrM) -'t Rd, I Address: 16 c s r L�U : e ailed: I - 4-'7' n Special Instructions. - QVQ,Irl l 1W aA'' Date Wanted: p.m. Requester: )- enrvt5 Rtlt5 Phone No.: —1(-4-1- O CI S in Approved per applicable codes. ❑ Corrections required prior to :approval. COMMENTS: ) ;11 A ' A. V' ❑ $30.00 REINSPECTION E REQUIRED. Prior to reinspection, fee must be paid at 6300 Soutticenter BIvd., Suite 100. Cali to schedule reinspection. eceipt No.: (:) INSPECTION RECORD Retain a copy with permit o. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206) 431 -3670 iiiio 1,,E . � ' .It U .S ,� --- • : •.: ' ctlons: eI , itt.(.�at,c.vr.0) (�(� n ( — 1 Date anted. 1 / -- --9 � 2— - u •.m. Requester: ;- ✓"-- 41-4l -c,.. Approved per applicable codes. ❑ Corrections required prior to approval. COMMENTS; ' youi oikc Inspector: Vag Date. 5,-44-92- 2- ❑ $30.00 REIN PECTION FEE REQUIRED. Prior to reinspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. CaII to schedule reinspection. BUILD1F PERMIT INSPECTION RECORD (Post with Building Permit In conspicuous place) CITY OF TUKWILA Department of Community Development - Permit Center 6300 Southcenter Boulevard, Tukwila WA 98188 (206) 431 -3670 SITE ADDRESS: 15425 53 Av S BUILDING (29!2 PERMIT NO. DATE ISSUED: SUITE NO.: PROJECT: Questar Center CALL FOR INSPECTIONS AT LEAST 24 HOURS IN ADVANCE "X" REQUIRED INSPECTIONS • PHONE DATE APPROVED INSPECT. INITIALS DATE(S) CORRECTION NOTICE ISSUED 1 Footings 431 -3670 2 Foundation 431 -3670 3 Slab and/or Slab Insulation 431 -3670 4 Shear Wall Nailing 431 -3670 5 Roof Sheathing Nailing 431 -3670 6 Masonry Chimney 431 -3670 7 Framing 431 -3670 — 8 Insulation 431 -3670 9 Suspended Ceiling 431 -3670 10 Wall Board Fastening 431 -3670 11 12 13 14 FIRE FINAL Insp: 575 -4407 X 15 PLANNING FINAL 431 -3670 X 16 PUBLIC WORKS FINAL 431 -3670 X 17 BUILDING FINAL 431 -3670 (INSPECTOR COMMENT SECTION ON REVERSE) INSPECTION PROCEDURES AND REQUIREMENTS All approved plans and permits shall be maintained available on the site in the same location. 1. FOOTING - When survey stakes and forms are set and rebar is tied in place. 2. FOUNDATION - When forms and rebar are in place. 3. SLAB - If structural slab or if underslab insulation is required. 4. SHEARWALL NAILING - Prior to cover. 5. ROOF SHEATHING NAILING - Prior to cover. 6. MASONRY CHIMNEY - Approximately midpoint. 7. FRAMING - After rough -in inspections such as mechanical, plumbing, gas piping, electrical and fire stopping is in place. 8. INSULATION - After framing approval, but before Installation of wallboard. Baffles must be Installed to keep attic ventilation points clear. 9. SUSPENDED CEILING - Fasten diffusers, lights and seismic bracing. 10. WALL BOARD FASTENING - Prior to taping (see UBC Chap. 47 and Table 47G). 11. 12. 13. 14. FINAL FIRE INSPECTION - Contact Fire Department for their requirements. 15. FINAL PLANNING INSPECTION - Contact Planning Department for their requirements. 16. FINAL PUBLIC WORKS INSPECTION - Contact Public Works Department for their requirements. 17. FINAL BUILDING INSPECTION - When all work, corrections, reports and other inspections are complete. OTHER AGENCIES: Plumbing (including gas piping) — King County Health Department -- 296 -4732 Electrical — Washington State Department of Labor and Industries — 277 -7272 A preconstruction meeting with the Building Inspector may be scheduled prior to starting the job by contacting the Department of Community Development, Building Division at 431 -3670. Although not required, a meeting of this type can often eliminate problems, delays and misunderstandings as the 09114103 project progresses. 09114103 I DATE INIT. d !..1‘' f l , ! 1 ir L iC i.I Y I J!w:' LOG COMMENTS D-7) � ,�► (A �� �,, C C' A , 10' _ 7)l a?.0 � _ -• c 1�1 ), r, V C t� :. „4 ,0 (� 1. r o (', fA3.x_. ■ ,:� • ,'�. • 1A \, MININENNISMINNWRINANIMM rt l f' . A ll.E / K . J . 1/10 ME..► , MA 1 . /A 4 A OM .0 I • 1 (# .�.+Oti 1: . . ik 9V1 cC .1� a�� 1 i I 0 1J,► +� l ; i.. , ; its t,�� ... � 1. � f. � ;�.1; ` � S 1.' ► i1 ..11 ►;►1 1 \ : i./ L, i)' /,�I.Ii :1L!�_.�•. 1) El G �l,4 i (4. • t •4,401K.. c '5 1 el? yr PL )(, &..... Cr 1)V)r W 5 \ 1N �► !�- lift W •_ i0.-.J� &OA ! v►p'noN 1610 0 IA* • '.i•...�. /i%.inl:: (� J / ._ ♦� of �. I 1 ! 41 . / J r....L O... ...: � - • r1...1�' . i/ ISO ..u. , 1 I .r. .__. .4 II .,..:s .:.4. • it ....d.. 0 g . • • ' �':/. /.. . 4 . •.'►,. '. Ai' ?. ,.l . #.4 4 +J v.' / 1 mil_. 1.►.►.�:.1 .'IL _ _. A ♦: ... . /!J. /`i./ 1... 1• .... _.1 1 -. .i_...:. .. _r Y * I + ,s Fr. L I .1. r1 <�... • Nowa._: _ .4 /.rJ .A 311 L 6 A U. s Y . ..' 1 — IMPOPINEMEMMINIMMORMISIM La i ,tell! March 6, 1992 City of Tukwila Department of Public Works Dennis Ellis Retaining Walls Northwest, Inc. 1299 156th Avenue N.E., # 150 Bellevue, WA 98007 SUBJECT: Dear Mr. John W. Rants, Mayor Ross A. Earnst, P. E., Director Questar Center (Retaining Wall), 15425 53rd Avenue South Utility Permit Approval (PC No. 91 -464) Ellis: The Public Works Department has reviewed and hereby approves the enclosed site plan for the subject development with changes as noted. Please contact the Permit Coordinator at 431 -3672 to have the following permits prepared for pickup: 1. Hauling Permit (Permit Fee = $25.00) The following documents shall be provided to Arline McCready in Public Works prior to any hauling activity: A. A copy of the Certificate of Insurance coverage (minimum of $1,000,000) naming the City of Tukwila as insured. B. A $2,000 bond made out to the City for possible property damages caused by activities. C. A map which shows the haul route. 2. Land Altering Permit (Permit Fee = $108.00) This fee was calculated using 700 cubic yards of imported fill as the measure of land altering activity. The permit fee breaks down as follows: Plan Review Fee = $ 22.50 Permit Fee - 85.50 Total $108.00 3. Storm Drainage Permit (Permit Fee = $25.00) 6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone: (206) 433.0179 • Fax (206) 431-3665 You are referred to other City agencies, including the Fire Department and the Building and Planning Divisions, for other requirements and approvals which may affect the commencement of this work. The above permits are being approved in accordance with the work shown on the enclosed approved plan. Any deviations from this plan should be submitted for additional review and approval prior to construction. If you have any questions or need clarification on any issue, please' call me at 433 -0179. Sincerely, • John A. Piero, P.E. Associate Engineer xc: City Utilities Inspector (w /copy of approved plan) Permit Coordinator Development File: Questar Center Read File Enclosure a/s JAP:amc:11:ellis RECEIVED ' 3 1992 NELSON L. LAYMAN JR. TRUCKING & EXCAVATING, INC. 34930 N.E. 14TH STREET CARNATION, WASHINGTON 98014 PH. # (206) 392 -9386 FAX # (206) 391 -5356 April 1, 1992 RETAINING WALLS NORTHWEST INC 1299 156TH AVENUE NE, #L -150 BELLEVUE WASHINGTON 98007 ATTN: Dennis Ellis RE: ROUTE MAP - QESTAR PROJECT From Burien: Hwy 518 - Use S. 154th St. ramp - 154th St. to Southcenter Blvd. & turn right into jobsite. (53rd Ave. S.) From Seattle: 1 -5 - Use Southcenter Blvd ramp & go straight into jobsite. (53rd Ave. S.) From Renton: 405 & Grady Way - Use W. Valley Hwy ramp - W. Valley Hwy to Southcenter Blvd. then west to 53rd Ave. S. & turn left into jobsite. From Federal Way: I -5 - Use Southcenter Pkwy. ramp, then north on Southcenter Pkwy & turn left up to Southcenter Blvd., then west on Southcenter Blvd. to 53rd Ave. S. & turn left into jobsite. . M:1570PITM • t•■• dYN 99 33S PL A.a REVIEW COMMEN1 Plan Check No..: " 1 I "" 44 REQUIRED INSPECTIONS ;311, 8 3 _ '' O -' tt si O - 420 a-, \D S 41 -5' Cra ..4) S •Y 3b -1°- girt! 1 g‘R .11 Project: No changes will be made to the plans unless approved by theAtte4iteet■ and the Tukwila Building Division. girt, I NEE . 2. Plumbing permit shall be obtained through the King County Health Department and plumbing will be inspected by that agency, including all gas piping (296- 4722). 3. Electrical permit shall be obtained through the Washington State Division of Labor and Industries, and all electrical work will be Inspected by that agency (277- 7272). 4. All mechanical work shall be under separate permit through the City of Tukwila. All permits, inspection records, and approved plans shall be posted at the job site prior to the start of any construction. 6. When special inspection is required, either the owner, architect or engineer shall notify the Tukwila Building Division of appointment of the inspection agencies prior to the first building inspection. Copies of all special inspection reports shall be submitted to the Building Division in a timely manner. Reports shall contain address, project name and permit number of the project being inspected. • 7. All structural concrete to be special inspected (Sec. 306, UBC). 8. All structural welding to be done by W.A.B.O. certified welder and special inspected (Sec. 306, UBC). 9. All high - strength bolting to be special inspected (Sec. 306, UBC). 10. Any new ceiling grid and light fixture installation is required to meet lateral bracing requirements for Seismic Zone 3. 11. Partition walls attached to ceiling grid must be laterally braced if over eight (8) feet in length. 12. Readily accessible access to roof mounted equipment is required. 13. Engineered truss drawings and calculations shall be on site and available to the building inspector for inspection purposes. Documents shall bear the seal and signature of a Washington State Professional Engineer. 14. Any exposed insulations backing material to have Flame Spread Rating of 25 or less, and material shall bear identification showing the fire performance rating thereof. ubgrade preparation including drainage, excavation, compaction, and ill requirements shall conform strictly with recommendations given in the soils repo p er4e- fineHns 16. A statement from the roofing contractor verifying fire retardancy of roof will be required prior to final inspection (see attached procedure). All construction to be done in conformance with approved plans and requirements of the Uniform Building Code (1988 Edition), All food preparation establishments must have King County Health Department sign -off prior to opening or doing any food processing. Arrangements for final Health Department inspection should be made by calling King County Health Department, 296 -4787, at least three working days prior to desired Inspection date. On work requiring Health Department approval, it Is the contractor's responsibility to have a set of plans approved by that agency on the job site. 19. Fire retardant treated wood shall have a flame spread of not over 25. All materials shall bear identification showing the fire performance rating thereof. Such identification shall be issued by an approved agency having a service for inspection at the factory. 20. Notify the City of Tukwila Building Division prior to placing any concrete. This procedure is in addition to any requirements for special Inspection. 21. All spray applied fireproofing, as required by U.B.C. Standard No. 43 -8, shall be special inspected. 22. All wood to remain in placed concrete shall be treated wood. 23. All structural masonry shall be special inspected per U.B.C. Section 306 (a) 7. Validity of Permit. The issuance of a permit or approval of plans, specifications and computations shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of this code or of any other ordinance of the Jurisdiction. No permit presuming to give authority or violate or cancel the provisions of this code shall be valid. 25. A Certificate of Occupancy will be required for this permit. 1. Footings 2. Foundation 3. Slab /Slab Insulation 4. Shear Wall Nailing 5. Roof Sheathing Nailing 6. Masonry Chimney 7. Framing 8. Insulation 9. Suspended Ceiling 10. Wall Board Fastening 11. 12. 13. 14. Fire Final 15. Planning Final 16. Public Works Final 17. Building Final ;311, 8 3 _ '' O -' tt si O - 420 a-, \D S 41 -5' Cra ..4) S •Y 3b -1°- girt! 1 g‘R .11 Project: No changes will be made to the plans unless approved by theAtte4iteet■ and the Tukwila Building Division. girt, I NEE . 2. Plumbing permit shall be obtained through the King County Health Department and plumbing will be inspected by that agency, including all gas piping (296- 4722). 3. Electrical permit shall be obtained through the Washington State Division of Labor and Industries, and all electrical work will be Inspected by that agency (277- 7272). 4. All mechanical work shall be under separate permit through the City of Tukwila. All permits, inspection records, and approved plans shall be posted at the job site prior to the start of any construction. 6. When special inspection is required, either the owner, architect or engineer shall notify the Tukwila Building Division of appointment of the inspection agencies prior to the first building inspection. Copies of all special inspection reports shall be submitted to the Building Division in a timely manner. Reports shall contain address, project name and permit number of the project being inspected. • 7. All structural concrete to be special inspected (Sec. 306, UBC). 8. All structural welding to be done by W.A.B.O. certified welder and special inspected (Sec. 306, UBC). 9. All high - strength bolting to be special inspected (Sec. 306, UBC). 10. Any new ceiling grid and light fixture installation is required to meet lateral bracing requirements for Seismic Zone 3. 11. Partition walls attached to ceiling grid must be laterally braced if over eight (8) feet in length. 12. Readily accessible access to roof mounted equipment is required. 13. Engineered truss drawings and calculations shall be on site and available to the building inspector for inspection purposes. Documents shall bear the seal and signature of a Washington State Professional Engineer. 14. Any exposed insulations backing material to have Flame Spread Rating of 25 or less, and material shall bear identification showing the fire performance rating thereof. ubgrade preparation including drainage, excavation, compaction, and ill requirements shall conform strictly with recommendations given in the soils repo p er4e- fineHns 16. A statement from the roofing contractor verifying fire retardancy of roof will be required prior to final inspection (see attached procedure). All construction to be done in conformance with approved plans and requirements of the Uniform Building Code (1988 Edition), All food preparation establishments must have King County Health Department sign -off prior to opening or doing any food processing. Arrangements for final Health Department inspection should be made by calling King County Health Department, 296 -4787, at least three working days prior to desired Inspection date. On work requiring Health Department approval, it Is the contractor's responsibility to have a set of plans approved by that agency on the job site. 19. Fire retardant treated wood shall have a flame spread of not over 25. All materials shall bear identification showing the fire performance rating thereof. Such identification shall be issued by an approved agency having a service for inspection at the factory. 20. Notify the City of Tukwila Building Division prior to placing any concrete. This procedure is in addition to any requirements for special Inspection. 21. All spray applied fireproofing, as required by U.B.C. Standard No. 43 -8, shall be special inspected. 22. All wood to remain in placed concrete shall be treated wood. 23. All structural masonry shall be special inspected per U.B.C. Section 306 (a) 7. Validity of Permit. The issuance of a permit or approval of plans, specifications and computations shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of this code or of any other ordinance of the Jurisdiction. No permit presuming to give authority or violate or cancel the provisions of this code shall be valid. 25. A Certificate of Occupancy will be required for this permit. CITY OF TUKWILA BUILDING DIVISION MEMO TO: FILE # 91 -464 FROM: RSB DATE: 3/11/92 SUBJECT: QUESTAR BLDG. RETAINING STRUCTURE. ***************************** * * * * * * * * * * * * * * * * * * * * * * * * * * * * * ** RETAINING STRUCTURE DESIGN WAS PRODUCED BY DESIGN EDGE SERVICES, INC. OF PORTLAND OREGON. THE ENGINEER OF RECORD WAS JOEL K. DEAN, P.E. STATE OF WASHINGTON. THE ORIGINAL SOILS INVESTIGATION AND REVISED DESIGN PERAMETERS WAS DONE BY CREATIVE ENGINEERING OPTIONS,INC. (GEOTECHNICAL ENGINEERS) OF BELLEVUE, WA. THE RETAINING STRUCTURE TO BE CONSTRUCTED IS COMPOSED OF PRECAST CONCRETE (INTERLOCKING) MEMBERS MANUFACTURED BY "CRIBLOCK" AND DISTRIBUTED BY RETAINING WALLS NORTHWEST,INC. OF BELLEVUE, WA. AND TO BE INSTALLED BY SAME. DESIGN IS CERTIFIED BY A WASHINGTON STATE LICENSED ENGINEER. AN INSPECTION OF THE SUBGRADE PRIOR TO BEGINING INSTALLATION OF THE "CRIBLOCK" WAS A CONDITION OF THE DESIGN PERAMETERS AND RECOMMENDED BY THE GEOTECHNICAL ENGINEER. THEREFORE, THIS CERTIFICATION OF THE SUBGRADE WILL BE MADE A CONDITION OF FINAL INSPECTION APPROVAL. CITY OF .:rwIL4 6200 Sotuhcenter Boulevard, Tukwila, Washington 98188 (206) 433 -1800 TO. 0-4//v./ . Sf✓• 'FiQ//V FROM: t/0/Y/ / DATE. z/.2/.2 SUBJECT: MEMORANDUM • t . a- .. • • _ � r 4 - - :. 4 / 1 • i r /az/R Fv ,-rA' ' z'gY/ h/_ T�FRL-- /7_,,w- f.' 4.'"1-1/ Pvd! i, !-/DRIBS" /JJ r lbw /c// lit R .SO /YE' PL.17/2/4/ //Y4' i sr'vES "WYE' ArP/S,EN 14'd4l /c// YOU / a4/7". 727 /1E' hr.�✓.EN A If i 4 .: +.1.J • /I i 1 • _.I _ /�✓¢ /4l!/O21///1/0' SE/2/S /7 ».E SIJ 5. sEGON)2..5 /4r"r %14 /TY 14/ 4.L I/4 rte T7/ /k'C/`- /d;e4L, o.- A a f'/I!/E' .41Y /; 1x" .2 /P.0 411 r et -cTL.Y ARoM e "? E [ D 7"' /P GL4/�l.4e 782 ?8.4' , 77 a4/4"' Y-,"& ..c4os.6-eY ;: {'. j1..r.7� +,1�1 ^t1:•�.y.. ............ . i ... 77,1ES.' /717`75 .gNa &LO f1Zr" ca/t/- 4EA'O'D JNH /.c-L /0e,ez /c n /a/PAkS C 4/C ?,VJ AeF A7-7AG4Mb/VTs (z) f4s. 08:' ` $w'N".D /7?, OBI! M /i" .e,44 r -/1.E t CITY OF TUKWILA BUILDING DIVISION MEMO TO: QUESTAR CENTER FILE # 91 -464 FROM: RSB DATE: 2/18/92 SUBJECT: PLAN REVIEW COMMENTS ***************************** * * * * * * * * * * * * * * * * * * * * * * * * * * * * * ** CALLED DENNIS ELLIS TO CONFIRM THE PROPOSED REQUIRED DRAIN LINE THAT IS TO BE INSTALLED BEHIND "CRIBLOCK ". ALSO, RECEIVED NEW PLAN TODAY WHICH SHOWS THE LOCATION OF RETAINING WALL IN RELATION TO EXISTING BUILDING. PLAN CALLS FOR THE INSTALLATION OF NEW DRAIN LINE BEHIND WALL AND CONNECTION OF THIS LINE TO EXISTING DRAIN LINE. A 4" DIA. PERFORATED PIPE WILL BE INSTALLED UNLESS EXCAVATION SHOWS THAT THE EXISTING LINE IS LARGER. IN THIS CASE AN EQUIVALENT SIZE LINE WILL BE INSTALLED. PLAN AND SPEC AND SOILS REPORT IS ADEQUATE FOR BUILDING DIV. PURPOSES. SOILS REPORT CALLS FOR INSPECTION OF EXCAVATION BY GEOTECH. ENGR. TO CONFIRM SOIL CONDITIONS PRIOR TO PROCEEDING WITH THE CRIBLOCK INSTALLATION. "CRIBLOCK" SPEC CALLS FOR SPECIAL INSPECTION BY RETAINING WALLS NORTHWEST, INC.. STAFF AND WRITTEN APPROVAL OF THE INSTALLATION PRIOR TO ACCEPTANCE OF ANY RESPONSIBILITY FOR THE PERFORMANCE OF THE "CRIBLOCK" WALL. WILL MAKE CONDITION OF PERMIT APPROVAL. ROUTE TO PUBLIC WORKS FOR REVIEW, THIS DATE. CITY OF T UKWILA 6200 SOUTHCENTER BOULEVARD, TUKWILA, WASHINGTON 98188 November 25, 1991 Mr. Gregory Rich 1201 Pacific Avenue, Suite 1450 Tacoma, WA 98402 PHONE q (206) 433.1800 Gary L. VanDuscn, Mayor RE: Plan Check No. 91 -464, Crib Wall Construction at 15425 53rd Av S., Tukwila, WA. Dear Mr. Rich: As we discussed today, SEPA (State Environmental Protection Act) review would be required for the proposal described above. A copy of the geotechnical analysis, recommendations and related materials should accompany the checklist in addition to the $225.00 fee. It is anticipated that upon receipt of the completed checklist, the SEPA process would take approximately two weeks. Feel free to contact me at 431 -3663 if you have any questions. Sincerely, Denni Shefrin, Associate Planner Enclosure. CC: 91-464 Permit File TO: FROM: DATE: SUBJECT: Rick Denni November 20, 1991 Planning Director Interpretation Requested... I am currently reviewing an application for a building permit for the construction of a crib wall to replace an existing rockery located at 15425 53rd Ave. S (see photos attached). The site is zoned C -2. TMC requires BAR review for exterior repair, reconstruction, or improvements, where the "cost exceeds ten percent of the building's assessed valuation... ". Based upon information provided by King County, the cost of improvements would exceed 10 %. Crib walls are commonly used for retaining walls in California which I'm sure you're familiar. Their appearance can be unsightly if not adequately vegetated. The applicant informed me that the replacement is in response to wall deterioration. In a letter dated April 12, 1991 from the applicant's geotechnical engineer, there is acknowledgement that the rockery is subject to ongoing distortion from tree growth, however, the degree of destabilization is unclear (see letter attached). The engineer observed additional signs of movement. What is unclear is the need to expedite the restoration /replacement because of safety concerns. Chapter 18.70 of the Zoning Code (Nonconforming Lots, Structures and Uses) provides for allowing for alterations or expansions of a nonconforming use if deemed unsafe. It appears from the information provided that the structural soundness of the existing wall may not pose an immediate threat and there may be opportunity for BAR review. Is there another way to ensure the wall is landscaped? The applicant argues the wall is behind the building and not visible. I disagree. The wall at a minimum is visible to tenants. The applicant also argues that the assessed value should be based on the entire project which site on 3 lots rather than the value of the lot where the wall is located. I have the geotech report. I would like direction on how to proceed. Thank you! encl: Photos Letter Dated April 12, 1991d from Glen Mann, Creative Eng. 'Ow 116116. REC. E' Creative Engineering Options INC. Geotechnical Engineers, Geologists & Environmental Scientists November 4, 1991 Mr. Dennis Ellis Retaining Walls Northwest 1299 - 152nd Avenue N.E. Bellevue, Washington 98007 Subject: Revised Crib Lock Wall Design Parameters Questar Center Rock Wall Replacement Tukwila, Washington 90 -1023 Reference: 1. Design Edge Services, Inc., memo regarding criblock retaining wall design criteria, dated 8/21/91. 2. Creative Engineering Options, Inc., letter regarding Criblock Wall Design Parameters, dated October 23, 1991. 3. Design Edge Services, Inc., memo regarding modified criblock retaining wall design criteria, dated 10/30/91. Dear Dennis: As requested, I have reviewed the geotechnical aspects of the modified criblock retaining wall design summarized on the referenced Design Edge Services memo (reference 3) for the subject project. These modifications are based on our comments (reference 2) derived from a review of the original memo, reference 1. My comments and conclusions are presented below. It is clear from this modified series of wall design criteria that the potential surface vehicle load surcharge has been accommodated into the original design. I had already assumed that the slope surcharge was included in the original design. The data on the Preliminary Design Table indicates that the factors of safety are all in excess of 1.93. Further, according to this table, with three minor exceptions, the toe and heel pressures are all within the allowable soil bearing pressure of the supporting site soil and, as such, are RECEIVED acceptable. CITY OF TUKWILA NOV 1 4 1991 PERMIT CENTER 5418 159th Place NE • Redmond, WA 98052 • (206) 883 -6889 • (206) 953 -1173 • FAX 881-3592 r Geotechnical Consultation Services 904081 Questar Center - Criblock Wall November 4, 1991 • Page 2 The minor exceptions occur where the wall height is fifteen (15) feet, or more. Here, the toe pressures presented on the table are 3,427 and 3052 psf. In addition, at the highest wall section, there is apparently a heel pressure of 3068 psf. As indicated in reference 2, considering that the real in -situ bearing pressure provided by the site soil is significantly greater than three thousand (3,000) psf, we do not see this as detrimental to the wall design or its long term integrity. H w. zwe;dotecoththend thaf:the • w " all, subgrade e t a aria otallest s e Ct101beCX111Cd: ;u heft ;exposed' tol,venfy that``adegifate .,bearingLis y`available If the soil appears to be soft or unstable, we will provide geotechnical recommendations for remedial treatment at that time. We appreciate the opportunity to be of continued services on this project and for the opportunity to review the modified criblock wall design criteria for this project. As indicated in reference 2, our comments and conclusions have been derived in a manner consistent with that level of skill, care and competence ordinarily exercised by other members of the profession in good standing currently practicing under similar conditions in this area. No other warranty, express or implied, is made. Should you have any questions about any point raised in this letter, or about any other geotechnical aspect of the project, please call. Very truly yours, CREATIVE ENGINEERING OPTIONS, INC. Glen Mann, P.E. President c.c.: gm /qucstar2 /cb 1 Mr. Greg Rich; Pacific Cities dream vba.ii6v , IVrf OCT 2 5 1991 Creative Engineering Options INC. Geotechriical Engineers, Geologists & Environmental Scientists October 23, 1991 Mr. Dennis Ellis Retaining Walls Northwest 1299 - 152nd Avenue N.E. Bellevue, Washington 98007 Subject: Crib Lock Wall Design Parameters Questar Center Rock Wall Replacement Tukwila, Washington 90 -1023 Reference: 1. Design Edge Services, Inc., memo regarding criblock retaining wall design criteria, dated 8/21/91. Dear Dennis: As requested, I have reviewed the geotechnical aspects of the criblock retaining wall design summarized on the referenced Design Edge Services memo for the subject project. My comments and conclusions are presented below. From the information presented on the Preliminary Criblock Retaining Wall Design Criteria sheet the values used appear to be generally conservative and in general accord with our earlier oral recommendations. The equivalent fluid pressure is omitted but, given the phi angle of 30°, this should be on the order of forty (40) pcf. Since there is a short slope above the top of the wall, and considering that there is a paved parking lot atop the slope, we also suggest that you include a surcharge loading to accommodate these conditions. In our professional opinion, a surcharge of fifty (50) psf acting over the full wall height should be adequate. The data on the Preliminary Design Table indicates that the factors of safety are all in excess of 1.99. Further, according to this table, with one minor exception the toe and heel pressures are all within the allowable soil bearing pressure of the supporting site soil and, as such, are acceptable. The minor exception is for a toe pressure of 3,006 psf. Considering that the real bearing pressure in the site soil is significantly greater than three thousand (3,000) psf, we do not see this as detrimental to the wall design or its long term integrity. 5418 159th Place NE: • Redmond, WA 98052 • (206) 883.6889 • (206) 953 -1173 • FAX 881 -3592 c Geotechnical Consultation Services 90 -1081 Questar Center - Criblock Wall October 23, 1991 • Page 2 The sketch provided on the Design Criteria sheet indicates that the drainage system is to be "by others ". While general recommendations were provided orally, it is clearly the responsibility of the contractor to install the drainage system and, as such, it must be part of the design. We appreciate the opportunity to review the criblock wall design criteria for this project. Our comments and conclusions have been derived in a manner consistent with that level of skill, care and competence ordinarily exercised by other members of the profession in good standing currently practicing under similar conditions in this area. No other warranty, express or implied, is made. Should you have any questions about any point raised in this letter, or about any other geotechnical aspect of the project, please call. Very truly yours, CREATIVE ENGINEERING OPTIONS, INC. Glen Mann, P.E. President c.c.: Mr. Greg Rich; Pacific Cities gm/questar /eb l 11/141/91 16:46 FAX 20(-'{83 7112 1ST CAPITAL 04cs11k mow► Creative Engineering Options INC. Geotechnical Engineers, Geologists & Environmental Scientists April 12, 1991 Mr. Greg Rich Pacific Cities P.O.Box 1193 Tacoma, Washington 98401 Subject: MAY 141991 Rockery Condition Questar Commerce Center Building Number 2 Tukwila, Washington Reference: CEO Inc., Letter regarding Rockery Construction Guidelines,. dated July 24, 1990. Dear Mr. Rich: [1002 90 -1081 As requested we have re- visited the subject site to evaluate the potential need for immediate rockery replacement. We visually examined the rockery along the west side of the site specifically noting the degree of visible damage or deterioration. Our comments and conclusions are presented below. From our visual examination of this rockery it is clear that the structure is currently subject to ongoing distortion from tree growth through the rockery face. This has resulted in lateral displacement of several rocks. What is unclear is the degree of destabilization that has occurred. In our professional opinion, this displacement is sufficient to be of concern and poses a potential threat to the building. Should this part of the rockery fail, it will almost certainly damage the building wall. We also noted some displacement of several rocks at the base of the highest part of the rockery in the southwest corner of the site. Apparently, these rocks have been moved laterally since construction. This movement has Ieft a void behind the rocks. Because of the height of the wall, we estimate about fifteen (15) feet high, we believe this too is a dangerous situation that, should the wall fail, could also lead to building darnage. 5418 159th Place NE • Redmond, WA 98052 • (206) 883.6889 • (206) 9534173 • FAX 881.3592 11/19/91 16:47 FAX 2 89 7112 1ST CAPITAL Geotechnical Consultation Services 90.1081 Questar Commerce Center Rockery April 12, 1991 U1003 Page 2 In addition, we noted that several individual rocks within the rockery structure are in the process of deteriorating. In time, these rocks will decay into a soil -like material and will lost their ability to support load. In this event, which may take several years, portions of the rockery may well collapse. In summary, there is in our opinion sufficient reason to be concerned about the stability and structural integrity of this rockery in the immediate future. While it is possible that, in spite of the visible distortion and deterioration, this rockery may last for several years in its present condition, it is equally likely that it will not. If it were to collapse or suffer localized failures there is a strong likelihood that as a result there will be damage to the building. It is also possible that such failure might also injure a passer by. We trust that this clarifies the situation for you regarding the need for rookery reconstruction. Should you have any questions about any point in this letter, or any other geotechnical aspect of the project, please call. Very truly yours, CREATIVE ENGINEERING OPTIONS, INC. k„,„ Glen Mann, F.E. President ,gnn/questar/b 10 11/10/01 16:47 FAX 20(183 7112 1ST CAPITAL 16001 The King County Assessor has assessed the subject for 1987 and 1988 as follows: 1987 1988 Land $ 146,400 $ 150,800 Improvements 647,200 642,800 Total Assessed Value $ 793,600 $ 793,600 The method used in this appraisal is to discount the projected future annual cash flows for an eleven year period through 1999. The basis of these projections is the lease with Radio Shack, a division of Tandy Corporation, and Cop - pinger Affiliates. Coppinger Affiliates originally signed a one -year lease commencing September 1, 1987, for 5,587 square feet. This lease was renewed last fall for an addi- tional one year term with a three-year option. The present rent is $7.41 per square foot per year on a fully serviced basis except for tenant janitorial service. A recent inspection of the subject facility indicates, that it is in fair condition. Conversations with Radio Shack in- dicate that new tenant improvements (carpeting, partition- ing) are scheduled soon as part of the lease renewal. The present carpet is worn in spots. Coppinger reports a prob- lem with sewer gas in the back rooms. Conversations with Radio Shack personnel indicate sales have been good. Radio Shack employs outside salesmen and thus does not rely solely on walk -in trade for sales. The sub- ject's highest and best use is as a retail outlet. Radio Shack has 4,151 square feet of space and the rent presently is $11.25 per square toot through the remainder of the lease, expiring September 30, 1990. The Coppinger Af- %s , z_ frOc_ Creative Engineering Options INC. A firm practicing in the geosciences May 26, 1992 First Interstate Plaza c/o First Capital Partners, Ltd. P.O.Box 1193 Tacoma, Washington 98401 Attention: Mr. Greg Rich Subject: Gentlemen: Introduction 90 -1081 Geotechnical Construction Monitoring Services Questar Center - Wall Replacement 15425 - 53rd Avenue South Tukwila, Washington As requested, and as part of our original scope of services, we have been providing geotechnical construction monitoring services at the subject site during the recent wall replacement operations. The primary purpose of our services has been to verify that the replacement criblock wall has been built in general accordance with the design/build contractors specifications and our original geotechnical design parameters. Our monitoring services were performed over the period of April 27, 1992 through May 22, 1992. During this period the contractor removed an existing partially failed rockery, excavated down to a firm and competent subgrade and cut back into the soil bank to provide room for a replacement wall. After the excavation was completed, the contractor erected a criblock wall that extended along the full length of the western side of the site. 5418 1591h Place NE • Redmond, WA 98052 • (206) 883.6889 • (206) 953.1 173 • FAX 867.9664 Geotechnical Construction Monitoring Services 90 -1081 Questar Center Replacement Wall May 26, 1992 Site Soil Conditions Page 2 The excavation exposed a firm and competent blue -gray silty sand to sandy silt from about the mid - height of the excavation to below the wall subgrade elevation. Above this, and extending up to the pre - construction ground surface, is a dense silty sand with rounded gravel. This upper layer is partially cemented -in- place. Wall Construction The subgrade excavation was sloped back into the cut face and was tamped before any of the concrete wall elements were placed. As the wall was constructed, from south to north, the cells were backfilled with a generally granular backfill material. The majority of this wall built along the west side of the site is of double cell construction. At the north end, where the wall height is significantly reduced, it becomes a single cell wall. The replacement wall measured approximately one hundred and thirty (130) feet in length. It varied in height between about two feet ant the northeastern end to approximately fourteen (14) feet at the southern end. The backfill material was periodically tested by a representative of Otto Rosenau & Associates. Copies of the field in -situ density test results and the laboratory optimum moisture and maximum dry density values are attached to this letter for your information. A total of forty -two (42) in -place density tests were performed in the cell backfill at randomly selected locations. In addition, five laboratory proctor tests were performed and formed the basis of the field fill testing program. On the basis of the in -place fill tests, it is evident that the cell fill has been compacted to at least 95 percent of the materials maximum dry density, as determined by ASTM D- 1557 -78 (Modified Proctor). This meets, or exceeds, the original project recommendations. When the criblock wall was completed, a rockery contractor was brought in to rebuild a small section of rock wall between the south end of the criblock wall and the pre- existing rockery. This reconstruction appears to have been done in a competent and professional manner, with suitable rock materials and in general accordance with the Associated Rockery Contractors Standard Rockery Construction Guidelines. EXPIRES 44 14,3 1 Geotechnical Construction Monitoring Services 90 -1081 Questar Center Replacement Wall May 26, 1992 Page 3 From our visual monitoring of the wall construction, it is evident that the wall has been constructed in general accordance with the original Retaining Walls Northwest, Inc., design/build recommendations. Summary In summary, based on our field observations and the in -place cell backfill test results, it is our professional opinion that this wall has been constructed in general accordance with the original geotechnical design parameters and the design/build contractor's recommendations. The construction is of a competent and professional finish, and is of materials specified in the contractor's design. In our opinion, this wall should be expected to function as originally intended throughout the lifetime of this project. Closure We trust this information is sufficient to allow you to complete this project without further hindrance. Our work has been performed in a manner consistent with that level of skill, care and competence ordinarily exercised by other members of the profession in good standing currently practicing under similar conditions in this area only. No other warranty, expressed or implied, is made. Should you have any questions about any point raised in this letter, or the attachments, or if we can be of further assistance to you, please call. Very truly yours, CREATIVE ENGINEERING OPTIONS, INC. Glen Mann, P.E. President Attachments: Field Construction Inspection Reports (6) Fill Test Result Sheets (10) gm/questar /eb4 QUESTAR CENTER TUKWILA, WASHINGTON RETAINING WALLS NORTHWEST, INC. 1299 156th AVE. NORTH L170 BELLEVUE, WASHINGTON 98007 DESIGN EDGE SERVICES, INC. 4520 SE BELMONT, SUITE 330 PORTLAND, OREGON 97215 NOVEMBER 11,1991 RECEIVED CITY OF TUKWILA NOV 14 1991 PERMIT CENTER SECTION 1 SECTION 2 SECTION 3 SECTION 4 GENERAL NOTES and DESIGN TABLES TYPICAL DETAILS CALCULATIONS STANDARD SPECIFICATIONS ■13•11111 GENERAL NOTES, 1.0 DESIGN CRITERIA 1.1 Average density of cribwall in place is taken to be 125 pounds per cubic foot. 1.2 Soil within the wall is to be compacted to obtain a density of 120 pounds per cubic foot. Compaction procedures are to be in accordance with the project soils engineers recommendations or Retaining Walls Northwest Incas. recommendations titled "STANDARD SPECIFICATION FOR CRIBLOCK CONCRETE WALL." 1.3 Backfill behind the wall is to be compacted to obtain a density of 120 pounds per cubic foot. Compaction procedures are the same as in item 1.2 above. 1.4 Sliding resistance is generated by internal soil friction with a coefficient of friction of TAN(30)= 0.577. 1.5 Lateral earth pressures are calculated based on Coulomb's equation for active earth pressure for cohesionless soils, 0 =30 °. 1.6 Maximum allowable soil bearing pressure is 3,427 p.s.f.. 1.7 A drainage system is to be provided that eliminates hydrostatic pressure on the wall. 1.8 The wall subgrade is to be inspected by Geotechnical Consultation Services prior to wall construction. 1.9 This analysis includes retaining wall stability only, it does not consider stability of the soil beyond the interface of the soil and the wall. 2.0 CONSTRUCTION 2.1 False headers are not allowed at ends of walls or in the top course of the wall. 2.2 Unsupported height at ends of the walls not to exceed 4 feet. 2.3 Refer to Retaining Walls Northwest, Inc's. STANDARD SPECIFICATION FOR CRIBLOCK CONCRETE CRIBWALL" and "CRIBLOCK" Standard Plans for further information. 3.0 DESIGN TABLE FOR 4' -6" HEADERS TOTAL WALL HEIGHT WALL TYPE Hi H2 TOE BEARING PRESSURE 8' -0" * Single Cell 8' -0" 2208 psf 9' -0" Double Cell 6' -0" 3' -0" 2379 psf 10' -0" Doable Cell 7' -0" 3' -0" 2841 psf 11' -0" Double Cell 3' -0" 8' -0" 2916 psf 12' -0" Double Cell 12' -0" 2126 psf. 13' -0" Double Cell 13' -0" 2512 psf 14' -0" Double Cell 14' -0" 2944 psf 15' -0" Double Cell 15' -0" 3427 psf * Maximum single cell height, see Section 3 for computations. ( 1. FIN. GRADE 1' -0". SOILS ENGINEER TO CONFIRM 4' -6" HEADER 12" i 2' ?RAMC SURCHARGE FIN. GRADE FRONT STRETCHER 4, 4 2 1 ‘.101)Ii‘to.r.% FALSE HEADER GRANULAR FILL 12" MIN. BACK STRETCHER DRAINAGE SYSTEM BY OTHERS „ SINGLE CELL DESIGN : EDGE SERVICES 4520 S.E. BELMONT PORTLAND, OREGON INC Drown SDC Chooic a JKD Job No. 2103591 Date 10 15 91 1 2' TRAFFIC SURCHARGE; 2 FIN. 11:7 GRADE FRONT STRETCHER 4' -6" HEADER FIN. GRADE 1 -0" . SOILS ENGINEER TO CONFIRM 12" MIN. DRAINAGE SYSTEM BY OTHERS DESIGN EDGE SERVICES, INC 4520 S.E. BELMONT PORTLAND, OREGON prawn SDI Cheok.d JKD Job No, 9103$91 Dot* • 10 15' 91 ***********************(A****************** * * * CNI BLOCK GRAVITY RETAINING WALL SYSTEM * * COULOMB METHOD OF ANALYSIS * * ************* * * * * * * * * * * * * * * * * * * * * * * * * * * * * * ** dU)II NAME / NUMBER: Questar Center / 2 L 03 91. INPUT CRITERIA: 11 -07 -1991 COMPOSITE DENSITY OF CRIBWALL SYSTEM. • 125 fIt) I I, DENSITY • 120 SOIL ]INTERNAL ANGLE OF FRICTION • 30 NUMBER OF CELL DEPTHS • 2 CELL HEIGHT H 1 • 7 CELL HEIGHT H 2 • 3 CELL DEPTH D 1 • 3.96 CE LL DEPTH D 2 • 7.67 WAI.,1., SLOPE (RATIO VERT:1) • 4 INITIAL BACKFILL SLOPE (RATIO HORIZ:1) ( NO'1'H1: '0' INDICATES LEVEL BACKFILL) 0 F1IE;CONI) BACKFILL SLOPE (RATIO HORIZ:1) (NOTE '0' INDICATES LEVEL BACKFILL).. 2 ()N'$' I NUOUS BACKFILL SLOPE (RATIO HORI I,1 I ) (N()'.1'n) I '0' INDICATES LEVEL BACKFILL) . • 2 1.NT CHANGE IN BACKFILL SLOPE FROM FRONT OF WALL • 1 2N1) CHANGE IN BACKFILL SLOPE FROM FRONT or WALL • 10 SURCUARGE IN FEET OF SOIL • 2 GRAVITY LOADS: LOAD MAGNITUDE ARM TO '0' MOMENT W 0 242.2687 5.319866 1288.837 W 1 3465 3.497364 12118.37 W 2 2876.25 4.0843 11747.47 W 3 221.3873 4.986533 1103.955 W 4 1558.2 6.335031 9871.245 (NO'VIt ALL LOADS CONTRIBUTE TO RESIST]NA OVERTURNING) SOIL PRESSURE LOADS: (CALCULATIONS BASED ON C1 LOMB' S METHOD) LOAD • MAGNITUDE ANGLE TO HORIZONTAL P 0 120.2778. 20 P 1 6367.809 33.88735 P 2 1828.673 5.963749 BOIL (PRESSURE LOCATION VECTORS FROM 'O' t VECTOR n 0 n 1. R 2. MAGNITUDE. ANGLE TO HORIZONTAL 10.93997 8.516694 7.806874 55.04979 30.00617 - 3.291497 SOIL PRESSURE INDUCED MOMENTS ABOUT 1011 LOAD MOMENT P 0 P 1 1' 2 1013.482 - 257.8132 22514.43 - 26185.31 - 815.2451 - 1480.841 (NOTE : POSITIVE MOMENT INDICATES LOAD CON'T'RIBUTES TO OVERTURNING, NEGATIVE MOMENT INDICATES LOAD CONTRIBUTES TO RESISTING) TOTAL, RESISTING MOMENT • 64053.83 TOTAL OVERTURNING MOMENT 1 22712.67 FACTOR OF SAFETY AGAINST OVERTURNING 1 2.8 20181 NORMAL REACTION AT BASE 1 .13532.69 '1'ANOHN'CIAL REACTION AT BASE 1 4000.914 1F'A1!'I'11I1 OF SAFETY AGAINST SLIDING 1 1 . ')2',173 MOIL (PRESSURE REACTION AT TOE 1 2114 I .05 ROM 1i (PRESSURE REACTION AT HEEL 1 607,6615 ********** *dk**** * * * * ***L * ** *** ** * **** *** ** * * * CYI1 I BLOCK GRAVITY RETAINING WALL SYSTEM * * COULOMB METHOD OF ANALYSIS * * ************* * * * * * * * * * * * * * * * * * * * * * * * * * * ** *** i1O13 NAME / NUMBER: Questar Center / 21.0:3391 INPUT CRITERIA: 11 -07 -1991 COMPOSITE DENSITY OF CRIBWALL SYSTEM • 125 SOIL DENSITY ▪ 120. SOIL INTERNAL ANGLE OF FRICTION • 30 NUMBER OF CELL DEPTHS • 2 CELL HEIGHT H 1 • 3 (:ELL HEIGHT H 2 • 8 CIgI II I I1EPTH D 1 • 3.96 C'PII J, DEPTH D 2 • 7.67 WAl Ila f1 t,OPE (RATIO VERT:1) • 4 INITIAL BACKFILL SLOPE (RATIO HORIZ :1) ( NO'I'P! e 101 INDICATES LEVEL BACKFILL) • 0 fiP N)ND BACKFILL SLOPE (RATIO HORIZ :1) (NOTE '01 INDICATES LEVEL BACKFILL) .. • 2 CONTINUOUS BACKFILL SLOPE (RATIO HORIZ :1) (NOTE: '0' INDICATES LEVEL BACKFILL) • 2 1ST CHANGE IN BACKFILL SLOPE FROM FRONT OF WALL • 1 2ND CHANGE IN BACKFILL SLOPE FROM FRONT OF WALL • 10 SURCHARGE IN FEET OF SOIL • 2 GRAVITY LOADS: 1LOAD MAGNITUDE ARM TO '0' MOMENT W 0 242.2687 5.562402 1347.596 W 1. 1485 4.224971 6274.082 W 2 7670 4.690639 35977.2 W 1 221.3873 5.229069 1157.649 W 4 667.8 7.224328 41124.406 (NO'1'PIt ALL LOADS CONTRIBUTE TO RESIST]NCi OVERTURNING) SOI1. PRESSURE LOADS: (CALCULATIONS BASED ON COILMB' S METHOD) LOAD MAGNITUDE ANGLE TO HOf 17,t)N''AL P 0 120.2778 • 20 P 1 6806.545 . 57.00388 P 2 4442.131 5.963754 M M-. +1 Sono PII MI3SURE LOCATION VECTORS FROM '0'3 VECTOR MAGNITUDE • ANGLE TO HORIZONTAL ?,UN't'A1.. R 0 R .1. R2 11.87945 11.10353 8.495211 56.77173 42.96903 11.42694 SotL PRESSURE INDUCED MOMENTS ABOUT '0'3 LOAD. P 0 P 1. P 2 MOMENT 1123.131 - 267.7905 28053.22 - 46381.45 7435.892 - 3843.113 (NU'!'t'I 1 POSITIVE MOMENT INDICATES LOAD <'OI1'1'11tTu TE5 TO OVERTURNING, NEGATIVE MOMENT INDICATES LOAD Ct)N'I'R,Lt1UTES TO RESISTING) '.1'C)'i'AI4 RESISTING MOMENT • 100073.3 TOTAL OVERTURNING MOMENT • 1A(112,24 11'Ac:'1'0fl OP SAFETY AGAINST OVERTURNING.: 2.733379 NORMAL ItMACTION AT BASE • 1.1)003.21 TANt1MN'I' 1 AL REACTION AT BASE 0 1990.565 FACTOR t* SAFETY AGAINST SLIDING • 2.604683 SOIL P1tPI?SURE REACTION AT TOE 291.6.463 SO1.L Plti';I3SURE REACTION AT HEEL 1777.986 * CRIBLOCK GRAVITY RETAINING WALL SYSTEM * COULOMB METHOD OF ANALYSIS * * ************* * * * * * * * * * * * * * * * * * * * * * * * * * * * * * ** Jon NAME / NUMBER: Questar Center / 21035391 INPUT! CRITERIA: COMPOSITE DENSITY OF CRIBWALL SYSTEM... SOIL, DENSITY SOIL INTERNAL ANGLE OF FRICTION NUMBER OF CELL DEPTHS ,.II.••. CELL HEIGHT H 1 Cf'31.L, DEPTH D 1 WALL SLOPE (RATIO VERT:1) 11 -07 -1991 125 120 30 1 • 12 • 7.67 • 4 INITIAL BACKFILL SLOPE (RATIO HORIZ:1) ( NOTES '0' INDICATES LEVEL BACKFILL). • 0 SECOND IACKFILL SLOPE (RATIO HORIZ:1) (NOTE '0' INDICATES LEVEL BACKFILL) • 2 CONTINUOUS BACKFILL SLOPE (RATIO HORIZ:1) (NOTE: '0' INDICATES LEVEL BACKFILL) • 2 1ST CHANGE IN BACKFILL SLOPE FROM FRONT OF WALL • 1 2ND CHANGE IN BACKFILL SLOPE FROM FRONT OF WALL • 10 SURCHARGE IN FEET OF SOIL • 2 GRAVITY LOADS: Lt1AD MAGNITUDE W (1 W I W 2 ARM TO '0' 1244.592 11505 830.5256 8.204423 5.17571 7.87109 (NOTE: ALL LOADS CONTRIBUTE Mon PRESSURE SSURE LOADS : M11M rwr 1()211.16 50c0:6.55 6'S37.142 TO RESISTING OVERTURNING) (t'A I d'I I I CATIONS BASED ON COULOMB'S METHOII) LOAD MAGNITUDE ANGLE TO HORIZONTAL P 0 P 1 547.8841 6228.871 20 5.963756 SOIL PU V SURE LOCATION VECTORS FROM '01: VECTOR 'MAGNITUDE ANGLE TO HORIZONTAL R 0 14.70011 R 1 9.245979 45.23724 19.91124 SOIL PRESSURE tSURE INDUCED MOMENTS ABOUT 'Of: LOAD MOMENT P 0 P 1 5373.669 1939.726 19507.61 -5626.07 (NOTE ! POSITIVE MOMENT INDICATES LOAD CUN'Vn.t f11TES TO OVERTURNING, NEGATIVE MOMENT INDICATES LOAD C(NTRIEUTES TO RESISTING) TOTAL RESISTING MOMENT • it a It li (1 . F 5 'l'(YI'AL OVERTURNING MOMENT • ;14I1t11., 28 FACTOR OF SAFETY AGAINST OVERTURNING.: 1,170432 NORMAL, REACTION AT BASE • 1.!1611 , 11 TANGENTIAL REACTION AT BASE • 1013,895 FACTOR OF SAFETY AGAINST SLIDING 2,990931 SOIL PRESSURE REACTION AT TOE 2t26054 SOIL PRESSURE REACTION AT HEEL 1944.496 * * * * * * * * * * * * * * * * * * * * * * * * *4 * * * * * * * * * * * * * * ** * * * Cf1RIACK GRAVITY RETAINING WALL SYSTEM * * COULOMB METHOD OF ANALYSIS * * * ************* * * * * * * * * * * * * * * * * * * * * * * * * * *h ** ** 11011 NAME / NUMBER: Questar Center / 2101'1'11. INPt1'I' ('IIIT'ERIA: 11 -07 -1991 COMPOSITE DENSITY OF CRIBWALL SYSTEM • 125 SOIL DENSITY • 120 SOtl, ;INTERNAL ANGLE OF FRICTION • 30 NUMBER OF CELL DEPTHS • 1 CELL HEIGHT H 1 • 15 CELL DEPTH D 1 • 7.67 WALL SLOPE (RATIO VERT:1) • 4 INITIAL BACKFILL SLOPE (RATIO HORIZ:1) ( NOTE: '0' INDICATES LEVEL BACKFILL) • 0 SECOND BACKFILL SLOPE (RATIO HORIZ:1) (NOTE '0' INDICATES LEVEL BACKFILL) ▪ 2 CONTINUOUS BACKFILL SLOPE (RATIO HORIZ:1) (NOTE: '0' INDICATES LEVEL BACKFILL) • 2 1ST CHANGE IN BACKFILL SLOPE FROM FRONT Or WALL • 1 2ND CHANGE IN BACKFILL SLOPE FROM FRONT Olr WALL • 10 SURCHARGE IN FEET OF SOIL 2 GRAVITY LOADS: LOAD MAGNITUDE ARM TO '0' MOMENT W 0 1244.592 8.93203 11116.73 W 1. 14381.25 5.539514 79665.13 W 2 830.5256 8.598697 7141.438 (NOTE: ALL LOADS CONTRIBUTE TO RESISTING OVERTURNING) SOIL PRESSURE LOADS: (CALCULATIONS BASED ON COULOMB'S METHOD) LOAD MAGNITUDE ANGLE TO HORIZONTAL P 0 547.8841 20 P 1. 8600.455 5.963756 SOIL PRESSURE LOCATION VECTORS FROM '0': VECTOR MAGNITUDE' ANGLE TO HORIZONTAL R 0 R 1 17.34681 9.936078 50.3067 25.43585 50IY, PRESSURE INDUCED MOMENTS ABOUT '0': LOAD P 0 P .1 MOMENT 6872.08 - 2076.07 36504.21 - 8018.055 (Nt)TR t POSITIVE MOMENT INDICATES LOAD Ct)N'I'I2.I I1ttTFS TO OVERTURNING, NMGATIVE MOMENT INDICATES LOAD CONTRIBUTES TO RESISTING) TOTALS MISTING MOMENT 11)11017.4 TOTAL OVHRTURNING MOMENT 4:1376.29 FACTOR OF SAFETY AGAINST OVERTURNING.: 2,490241 NORMAL, REACTION AT BASE • 19213.21 TANGENTIAL REACTION AT BASE • 4544.552 FACTOR OF SAFETY AGAINST SLIDING • 2.44089 SOIL PRESSURE REACTION AT TOE • 3427.135 SOIL PRESSURE REACTION AT HEEL • 1582.829 ,CRIBL.QCK TYPICAL NOMENCt.A1URE (1 ern SYSTEM SI TOWN COUL Mlt" UNIFORM WALL SLOPE —� PT' O' --� JRCHARGE 1 BACKFILL SLOPE (c)) eRs P,1 AN(W N I IAL REACTION NO?ESs 1OE PRESSURE 1. EARTH PRESURE CALCULATIONS BASED ON COULOMB'S EQUATION FOR ACTIVE PRESSURE FOR COHESIONLESS SOILS, 2, P= KAVH2 /2 3, KA COS' ($ -p) cosv cos(d+p)`1+ SIN t +8 SIN -w)�j LL COS a +/3 COS w- 4, = IN1EIZNAL ANGLE OF FRICTION w = BACKFILL SLOPE 6 = WALL BACKFILL FRICTION =2/3 $ a ANALYSIS PLANE ANGLE TO VER 1 ICAL, COUNTERCLOCKWISE POSITIVE. y say 5 BACKFILL OM 6 =2/3$ TYP �-- ANALYSIS PLANE ��— HEEL PRESSURE NORMAL REACTION r �ti Ira NTAIP91 r1161%0 (-5? /2(-- Creative Engineering Options INC. Geotechnical Engineers, Geologists & Environmental Scientists October 23, 1991 Mr. Dennis Ellis Retaining Walls Northwest 1299 - 152nd Avenue N.E. Bellevue, Washington 98007 Subject: Crib Lock Wall Design Parameters Questar Center Rock Wall Replacement Tukwila, Washington 90 -1023 Reference: 1. Design Edge Services, Inc., memo regarding criblock retaining wall design criteria, dated 8/21/91. Dear Dennis: As requested, I have reviewed the geotechnical aspects of the criblock retaining wall design summarized on the referenced Design Edge Services memo for the subject project. My comments and conclusions are presented below. From the information presented on the Preliminary Criblock Retaining Wall Design Criteria sheet the values used appear to be generally conservative and in general accord with our earlier oral recommendations. The equivalent fluid pressure is omitted but, given the phi angle of 30°, this should be on the order of forty (40) pcf. Since there is a short slope above the top of the wall, and considering that there is a paved parking lot atop the slope, we also suggest that you include a surcharge loading to accommodate these conditions. In our professional opinion, a surcharge of fifty (50) psf acting over the full wall height should be adequate. The data on the Preliminary Design Table indicates that the factors of safety are all in excess of 1.99. Further, according to this table, with one minor exception the toe and heel pressures are all within the allowable soil bearing pressure of the supporting site soil and, as such, are acceptable. The minor exception is for a toe pressure of 3,006 psf. Considering that the real bearing pressure in the site soil is significantly greater than three thousand (3,000) psf, we do not see this as detrimental to the wall design or its long term integrity. 5418 159th Place NE • Redmond, WA 98052 • (206) 883 -6889 • (206) 953 -1173 • FAX 881.3592 Geotechnical Consultation Services 90 -1081 Questar Center - Criblock Wall October 23, 1991 Page 2 The sketch provided on the Design Criteria sheet indicates that the drainage system is to be "by others ". While general recommendations were provided orally, it is clearly the responsibility of the contractor to install the drainage system and, as such, it must be part of the design. We appreciate the opportunity to review the criblock wall design criteria for this project. Our comments and conclusions have been derived in a manner consistent with that level of skill, care and competence ordinarily exercised by other members of the profession in good standing currently practicing under similar conditions in this area. No other warranty, express or implied, is made. Should you have any questions about any point raised in this letter, or about any other geotechnical aspect of the project, please call. Very truly yours, CREATIVE ENGINEERING OPTIONS, INC. I�- Glen Mann, P.E. President c.c.: Mr. Greg . Rich; Pacific Cities gm/questar /eb 1 Creative Engineering Options INC. Geotechnical Engineers, Geologists & Environmental Scientists November 4, 1991 Mr. Dennis Ellis Retaining Walls Northwest 1299 - 152nd Avenue N.E. Bellevue, Washington 98007 Subject: RECEIVED JAM 2 8 1993 COMMUNITY OEVELOPIVMENT Revised Crib Lock Wall Design Parameters Questar Center Rock Wall Replacement Tukwila, Washington 90 -1023 Reference: 1. Design Edge Services, Inc., memo regarding criblock retaining wall design criteria, dated 8/21/91. 2. Creative Engineering Options, Inc., letter regarding Criblock Wall Design Parameters, dated October 23, 1991. 3. Design Edge Services, Inc., memo regarding modified criblock retaining wall design criteria, dated 10/30/91. Dear Dennis: As requested, I have reviewed the geotechnical aspects of the modified criblock retaining wall design summarized on the referenced Design Edge Services memo (reference 3) for the subject project. These modifications are based on our comments (reference 2) derived from a review of the original memo, reference 1. My comments and conclusions are presented below. It is clear from this modified series of wall design criteria that the potential surface vehicle load surcharge has been accommodated into the original design. I had already assumed that the slope surcharge was included in the original design. The data on the Preliminary Design Table indicates that the factors of safety are all in excess of 1.93. Further, according to this table, with three minor exceptions, the toe and heel pressures are all within the allowable soil bearing pressure of the supporting site soil and, as such, are acceptable. 5418 159th Place NE.. Redmond, WA 98052 • (206) 883 -6889 • (206) 953 -1173 • FAX 881 -3592 Geotechnical Consultation Services 90 -1081 Questar Center - Criblock Wall November 4, 1991 Page 2 The minor exceptions occur where the wall height is fifteen (15) feet, or more. Here, the toe pressures presented on the table are 3,427 and 3052 psf. In addition, at the highest wall section, there is apparently a heel pressure of 3068 psf. As indicated in reference 2, considering that the real in -situ bearing pressure provided by the site soil is significantly greater than three thousand (3,000) psf, we do not see this as detrimental to the wall design or its long term integrity. However, we do recommend that the wall subgrade in the area of the tallest section be examined when exposed to verify that adequate bearing is available. If the soil appears to be soft or unstable, we will provide geotechnical recommendations for remedial treatment at that time. We appreciate the opportunity to be of continued services on this project and for the opportunity to review the modified criblock wall design criteria for this project. As indicated in reference 2, our comments and conclusions have been derived in a manner consistent with that level of skill, care and competence ordinarily exercised by other members of the profession in good standing currently practicing under similar conditions in this area. No other warranty, express or implied, is made. Should you have any questions about any point raised in this letter, or about any other geotechnical aspect of the project, please call. Very truly yours, CREATIVE ENGINEERING OPTIONS, INC. Glen Mann, P.E. President c.c.. gm/questar2/eb 1 Mr. Greg Rich; Pacific Cities healv Retaining Walls Northwest, Inc. March 2, 1993 Dave Larson Building Department City of Tukwila 6300 Southcenter Blvd Tukwila, WA 98188 RE: Qestar Center Rockery Replacement Ntanufacturcr's Final Letter Dear Mr. Larson, ?4R ' 1993 ( f`�L�71aA7t:I�tt This letter is to confirm that the CRIBLOCK retaining wall located,at 15425 53rd Ave S. was constructed in compliance with the manufacturer's standards and procedures for installing this wall system. Enclosed is a copy of the "Standard: Specification for Concrete Cribwalls" for your review. The cribwall was founded can soil deemed' competent by the geOtechnical engineers. The backfilling and compaction+lang with the material used for backfilling, were carried out in accordance with the recommendation of the geotechncal.,report and the on -site investigator. sx' :`': 1i 1t.�; .,,rftr:.i. �r.:; �. q. M1::� In addition, the retaining w I1('as constructed rnd,tf a .perfo `ated drain pipe was installed per the design of Dcsign;Edge Services, Inc . tw,,,, Should you have by quest anssregarding this please;.,c l r ne. nos . ,.. � ;1' Since:eiy Dennis A. Ellis Retaining Walls Northwest, Inc. 1299 156th Ave. N,E, #L -150 • Bellevue, WA 98007 (206) 747-0956 • 1- 800 -877 -0956 • Fax (206) 747 -5892 Creative Engineering Options INC. Geotechnical Engineers, Geologists & Environmental Scientists April 12, 1991 Mr. Greg Rich Pacific Cities P.O.Box 1193 Tacoma, Washington 98401 Subject: Rockery Condition Questar Commerce Center Building Number 2 Tukwila, Washington Reference: CEO Inc., Letter regarding Rockery Construction Guidelines, dated July 24, 1990. Dear Mr. Rich:. 90- 1081 As requested we have re- visited the subject site to evaluate the potential need for immediate rockery replacement. We visually examined the rockery along the west side of the site specifically noting the degree of visible damage or deterioration. Our comments and conclusions are presented below. From our visual examination of this rockery it is 'clear that the structure is currently subject to ongoing distortion from tree growth through the rockery face. This has resulted in lateral displacement of several rocks. What is unclear is the degree of destabilization that has occurred. In our professional opinion, this displacement is sufficient to be of concern and poses a potential threat to the building. Should this part of the rockery fail, it will almost certainly damage the building wall. We also noted some displacement of several rocks at the base of the highest part of the rockery in the southwest corner of the site. Apparently, these rocks have been moved laterally since construction. This movement has left a void behind the rocks. Because of the height of the wall, we estimate about fifteen (15) feet high, we believe this too is a dangerous situation that, should the wall fail, could also Lead to building damage. RECEIVED CITY OFTUKWILA NOV 1 4 1991 PERMIT CENTER 5418 159th Place NE • Redmond, WA 98052 • (206) 883 -6889 • (206) 953.1173 • FAX 881 -3592 Geotechnical Consultation Services 90 -1081 Questar Commerce Center Rockery April 12, 1991 Page 2 In addition, we noted that several individual rocks within the rockery structure are in the process' of deteriorating. In time, these rocks will decay into a soil -like material and will lost their ability to support load. In this event, which may take several years, portions of the rockery may well collapse. In summary, there is in our opinion sufficient reason to be concerned about the stability and structural integrity of this rockery in the immediate future. While it is possible that, in spite of the visible distortion and deterioration, this rockery may last for several years in its present condition, it is equally likely that it will not. If it were to collapse or suffer localized failures there is a strong likelihood that as a result there will be damage to the building. It is also possible that such failure might also injure a passer by. We trust that this clarifies the situation for you regarding the need for rockery reconstruction. Should you have any questions about any point in this letter, or any other geotechnical aspect of the project, please call. Very truly yours, CREATIVE ENGINEERING OPTIONS, INC. Glen Mann, P.E. President gm/questar/b10 ti Creative Engineering Options INC. Geotechnical Engineers, Geologists & Environmental Scientists July 24, 1990 Capital Consultants Capital Center 2300 S.W. First Avenue Portland, Oregon 97201 Attention: Ms. Karen I. Blomquist Subject: Rockery Construction Guidelines Questar Commerce Center Building Number 2 Tukwila, Washington Reference: Plot Plan and Legal Description for Questar Commerce Center, Building No. 2 undated, provided by NDT Engineering Corp. Seattle, Washington. Dear Ms. Blomquist: 90 -1081 Introduction As requested, this letter provides our recommendations and construction guidelines for a replacement rockery along the west side of the subject site in Tukwila, Washington. We understand that you are concerned because the existing rockery is suffering some minor distress due to tree growth, and also that there is little space currently available between the existing building and the rockery. We also understand that there are several potential rockery construction options being considered regarding the space between the rockery and the building. We are proceeding with our services on the basis of your written of July 17, 1990 authorization. Project Description From our discussions, we understand you wish to remove an existing rockery which was constructed along the west side of the subject site about four to five feet away from the existing building's wall. This rockery is currently suffering some minor distress because of recent 5418 159th !'lace NE • Redmond, WA 9f3052 • (206) 883.6889 • (206) 953.1173 • FAX 881.3592 • Geotechnical Consultation Services 90 -1081 Questar Commerce Center - Building 2 Rockery July 24, 1990 Page 2 tree growth which is occurring through and within the rockery structure. Once the existing rockery has been removed, you wish to replace it with another. You are also considering several options that will reduce the somewhat claustrophobic feeling that exists between the existing rockery and building and, if possible, you wish to increase the space between the rockery and building. You would like to create sufficient space to allow for truck loading /unloading. The height of the existing rockery varies between approximately twelve (12) feet at the south end to seven feet at the north end. There is an approximately 2:1 (horizontal:vertical) slope above the rockery which extends to the property line. The rockery is approximately one hundred and twenty (120) feet long in a south to north direction. This structure also connects to another rockery extending onto adjacent property to the south. Development Options As indicated above, you are considering three rockery options for this space. According to the referenced Plot Plan, there is about twenty - three (23) feet between the building and the property line in which to reconstruct the rockery or build a new system. The potential options currently under consideration are: 1. Remove and replace the existing rockery with a similar rockery construction in the same location, 2. Remove and replace the existing rockery with a two stage rockery to create a more open area next to the building. or 3. Remove the existing rockery, excavate back toward the property line and build a new single stage rockery to create a load /unload area. On the basis of the space available (twenty -three [23) feet) and the approximate height of the ultimate excavation (about fourteen [14] to nineteen [19) feet) there does appear to be sufficient space to either reconstruct the existing rockery or to overexcavate and construct a new single stage rockery. 'Geotechnical Consultation Services 90 -1081 Questar Commerce Center - Building 2 Rockery July 24, 1990 Page 4 Rockery Construction Guidelines, by virtue of the mass of the rocl: used and its mechanically interlocking nature, some undetermined degree of gravity retention is achieved. Hence, the larger the rock used the greater the in -place mass and therefore the greater degree of retention that will exist. In our experience, it has been proven that sound construction practice typically results in the production of a competent and long lasting rockery. To help achieve this goal, we recommend the ARC Standard Rockery Construction Guidelines be closely adhered to during construction. A copy of these guidelines is attached for your information and use. If there should be a conflict between the recommendations in the guideline and this letter, this letter will govern. We have also provided a pictorial representation of the rockery's approximate location as Sheet 1 of 3. A sectional view of the higher section of the replacement rockery is provided on Sheet 2 of 3, and the set -back rockery on Sheet 3 of 3. These sketches are attached for your, and your contractor's, information and use. Keyway Once the appropriate excavation has been completed into the soil face to be protected, your contractor must provide an adequate keyway for the rockery. The keyway should extend at least twelve (12) inches down into the underlying competent native soil. It should be wide enough to place the basal rock and the filter drain rock layer, typically a distance of about five to six feet. The surface should slope very gently,back to the rear of the keyway where a perforated or slotted drain line should be installed. The keyway subgrade should be proofrolled to tighten up the exposed surface. A walk- behind, twin vibrating drum steel wheel roller is adequate for this purpose. Such a roller can be found at most local, rental stores. Any soft or potentially unstable areas should either be overexcavated and replaced with a compacted structural fill (described later in this letter) or, the area should be overlain with a layer of about ten-(10) to twelve (12) inches, or more, of quarry spalls (two to four inch size). The spalls should then be tamped firmly into the subgrade to tighten it sufficiently to support the rockery load. Geotechnical Consultation Services 90 -1081 Questar Commerce Center - Building 2 Rockery July 24, 1990 Basal Rocks Page E Once the keyway has been prepared, the basal row of rock should be firmly tamped into place. Because of the nature of this site, and given the height of the rockery, we recommend that the basal row of rock consist of six -man size rocks only. As each rock is placed onto the keyway subgrade it should be tamped with the rock placement crane to firmly seat it into the underlying subgrade soil. Each rock should be placed in a manner that will achieve the best rock -to -rock fit and leave as little interstitial void space as possible. Rockery Construction Once the basal row of rock has been placed under either option, the construction of the rockery wall can continue. We recommend that for option 1 six -man size rock be used in the lower one third of the rockery, we estimate at least one to two rows from the keyway subgrade. Above this point, there should be one row of five man rock then the remainder should be of no less than four man -sized rock. For option 3, we recommend approximately the lower one half be of six - man sized rocks, an estimated three rows of rock. Above this should be one row of five -man rock with the remainder of four -man rock. All rockery rock should be placed so that the larger rocks are towards the base of the rockery and the smaller rocks towards the top. Wherever possible, the rocks should be placed with the longest rock dimension set back towards the soil face being protected. This will result in less face area of rock being presented, but a more structurally competent wall. It is also important that the rocks be placed in such a manner as to achieve the closest possible rock -to- rock contact both vertically and horizontally, and to leave as little void space as possible. Face Batter We recommend that the inclination, or batter, of the face of the rockery be set at 1:5 (horizontal:vertical). This should provide :. clean, stable, and structurally sound rockery face. By generating a slightly flatter face it should also be possible to reduce the "chasmlike" effect next to the building and make the space lighter. 'Ceotechnical Consultation Services 90 -1081 Questar Commerce Center - Building 2 Rockery July 24, 1990 Filter Rock Layer Page 6 As the rockery is raised, a layer of crushed filter rock must be placed between the rear face of the rocks and the soil face being protected. This rock should be about two to four inch sized crushed rock and should be soil free. As it is placed behind the rock, it should be tamped with the crane bucket to achieve as tight a fit as possible. The filter layer is raised contiguously with the rockery. The surface of the filter layer should be covered with an impermeable layer, such as visqueen, filter fabric or building paper. We recommend you backfill over this with a compacted impermeable soil fill in which a new vegetative cover can be grown. This will prevent surface water from seeping through into the rockery's filter layer. For this rockery we recommend that the filter rock layer be no less than eighteen (18) inches thick. Soil Slopes While it is preferable to have an essentially level soil surface above a rockery, in this case there will be a slope between the top -of- rockery and the property line. We, therefore, recommend that any sloping soil surface above a rockery be kept to a gradient of 2H:1V, or flatter. Achievement of this slope gradient will'probably govern the actual maximum height of the rockery. A surface with this slope can be easily constructed or, in the case or an existing native slope. can be easily recompacted to provide a competent surface. We also recommend that any soil surface above a rockery be seeded with a rapid growth, deep rooted vegetative mat as quickly after construction is completed as possible. This will tend to help seduce the potential for surface erosion, the rate of surface water infiltration and raindrop impact. You may also wish to use a pegged in -place jute matting, or other geotechnical fabric, to help maintain the seed and mulch in -place until the root mat has had an opportunity to germinate and take hold. Precautionary Measures As indicated above, a rockery is not a retaining wall. It is more susceptible to damage from exterior causes than, for example, cr.e would expect a reinforced concrete wall to be. Therefore. to achieve a stable and long lasting rockery structure we recommend that certa:::, Ceotechnical Consultation Services 90 -1081 Questar Commerce Center - Building 2 Rockery July 24, 1990 Pape practices be totally avoided once the rockery is complete. Where:•:::_ possible, excavation work should be performed before the rockery reconstruction gets underway. We recommend that no excavation be performed within five feet of the top of any rockery. This will help prevent the potential for co:' ap:.: back into the excavation area of the upper rockery rocks should sail support be removed. More importantly, no excavation work should be conducted between L.ha toe of the rockery and the existing building, nor should any excavation penetrate into an area defined by a 1H:1V line extended down from the front edge of the basal rock of the rockery. This will help prevent the possibility of undermining any rock and thus eliminating some portion of the rockery's foundation support. Drainage As indicated earlier, a perforated or slotted drain line is placed at the back edge of the keyway to collect any keyway subgrade seepage•or surface water flow that filters down through the filter rock laye=r. The pipe should have a minimum diameter of four inches, be bedded on a free - draining material (such as coarse sand or pea - gravel) with the perforations or slots facing down. It should be tightlined to a positive and permanent discharge, such as a nearby storm drain. Use of Fabric There are wide variations of opinion regarding the use of fabric in rockery construction to "prevent" fines being flushed from the protected soil face out through the rock filter layer. In our opinion, and after detailed discussions with several f brig• manufacturers representatives, fabric should not be used in rockery. construction of this nature. For a geotechnical drainage fabric to function as designed. the manufacturer recommends that the interface between the soil fa :-e. fabric and backfill (the rockery filter rock in this case) should he such that the fabric is very tightly sandwiched between th= hackfill. This sandwiching effect keeps the filter cloth flat an: in close contact with the surrounding soil which is what prevents soil particles from moving. 2 3 4 5 8 7 8 9 10 11 12 13 14 15 18 17 18 19 20 21 22 23 24 25 28 27 28 29 30 31 32 33 34 35 as 37 38 39 40 41 42 43 44 45 Creative Engineering Options INC. Geotechnical Engineers, Geologists & Environmental Scientists PROJECT QVes4'ar B%1 2 R.ockcry SUBJECT Roc.li.ern LoL�+ion Sk,e�ah PROJECT NO. 90 -108% SHEET 1 OF g COMPUTED BY (rAq DATED ,12.4-T90 CHECKED BY DATED 5chemorf is Con y - tJo♦ To Se-a Approxi,Mfe 6oc.w•1170n - 0e4i•►, 3 roc.iwry 1 r • • • r y .l 'Pro Qr ( AWeitit%ate IOGA4i•N -Ophen t rncker3 Line 'Z,_�,a� - -E ; ins rvc •ry • i RAVIo SHAck) --�� . 60 i 53rd ftvenoe Sow crh 3 , 'r41H Mot Mau, NI • Redmond, WA 98057 • (2O', IR11(rIMII9 • 170619r, 1173 I'Ii* EIM-3591 1 2 3 4 5 7 8 9 10 11 12 13 14 15 1e 17 18 19 20 21 22 23 24 25 28 27 28 29 30 31 32 33 34 35 36 37 38 31 4 4 4 4 4 4 Creative Engineering Options INC. __ PROJECT NO. 50 -10E11 rcn ..'cyho SHEET 2 OF 3 Geologists A Environmental Scientists Ceolechnical Engineers. PROJECT Giules +ar 1314.2. - ►2oclt,ery COMPUTED BY GM DATED 9-124190 SUBJECT OrViov 1 Ro ckef�- Sec*ion CHECKED BY DATED • +I _. N.. ±:. II t 3-_- . L.9.1—e- .n III SEM Itralli al 11111011A 1� ligl_ t o s � i a %, fi■■■iirr■ ■ ■ a "WI ■rr�rin V 1 n !lig% ( f ■■IE /m . i r ■ r7 + V44I # ■ WWII ■r■r n �► WARM MM ■ OM ■ ■ `*iii_ ��' r �U ■ ■■■ ■■ ■■ ILa��►.�1 ■r ■■�■� Imo ■ ■r r:� Nif ill■■■ %■r ■ ■■■ 91■ I ■�■■■ - -, r O�:� � A. 1::!,:.i !.A� �■■U■■ • F-'-IiIiflhiIhOhIIIIflIUIII ■■ ■■r ■ ■rn�r■■■�■ li.���;r■r ■ ■■■■■■ ■■■■�■■■■r■ ■■ r; ■■11 ■■■N ■■■e■rr k — �- - o >Siw,j1 -v►, e. Ai_k r,.w r► 4 h. M! e. - rr'•• f'lil'I•e . __ .� t C ,v4 -MISR Mal • '�o_ -__re - ■ In1YY1low% (•% P�e� U_,. m !a ,W _. �s1 I 14.1a �� fi'yAf,Te VA1 •die iz. 4 60. __ .- ..1..- .4- -_1_.. _ �� s f rsji_le.Ape ... . _...,........... 4._,I. 1.,1 1 i !I .._ +..........., 1 L 1 « i 1-1-------- ' - i ' ,....._......... -! .._,......... .... _.. -i--t _ -- --- .... c i IT 5418 159111 Place NE • Redmond. WA 98052 • I1(X,1 883 NUN • I20(J 95.1.1173 • FAX 881.3597 2 3 4 5 e 7 8 9 10 11 12 13 14 15 18 17 18 19 20 21 22 23 24 25 28 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 54111 159th Place NI-. • Redmond, WA 98057 . 17(36181)3 (8119 • 17(6) 953 1173 FAX 881.v" Creative Engineering Options INC. PROJECT CHECKED NO. So -1081 0'08"11 %.cv PROJECT SUBJECT MINIE1011111.1111111WIlli Geotechnlcal Engineers. Geologists � Emlronmental krenusts QNeS4- r '81ds , 2- 12.0 cl.kery SHEET COMPUTED 3 OF 3 BY BY GM DATED $12059 O J4jor%3 2ackery - $V.AjoA DATED _ _.._ IIIIL 5 e_m.c� . ._!_ ki_l = N. ' ` Ih� 1:- r Sco, Ceaillil I>11 - e e �L�e s3 e • 1 ').. •, Deb •, :- .....„.... - ... r N. - ---; si d 4 40111110., N C 1111/. 111111I'L4!PJ1L.HVJ 1161 KARAM' MIN NI rII1Ii1L:IwIu1I ■ �■:� FE 11 ■er 1 I tr MM. isrularr-arguma- ■ ammo . ■■r■■Er■AI■■ ■ II immaialorioRacmgmmImm ■■■■ ■i.. ■■■■■■■ 1 •■■■■■■■ ■ ■ ■ ■■■ NM • m ■ ■ N • �' t S :_ ■■ ■ ■■ ■ ■■■■� ....::■r _. . 1. -__-. 1 • _'_.MInl ` _ m mwxi IM!!Xt Q px1 Dt„.� ' I ;_... v ylA!1 .V_ __�lw►. _ ._ ._ �livrt~ g . s m... 'EirM1�'�'��. lihaIv +-I-f-II Wi. si q _ ro t: .f' ck Hi'- _ u'4_ (��c si y, ^ _. - • . kh- ■ ■■r . ■� EMS S tel ! ' k e,Att'ri av . _ }} -_ ___,.._.. ._- _.._._ 10 �.... .. AMINIMINIMMIN .__ 54111 159th Place NI-. • Redmond, WA 98057 . 17(36181)3 (8119 • 17(6) 953 1173 FAX 881.v" ARCR a sso•m. o4aaoelated ?2oeker, eo#ttactara P.O. Box 1794 Woodinville, Washington 98072 (206) 481 -3456 or (206) 481 -7222 ASSOCIATED ROCKERY CONTRACTORS STANDARD ROCKERY CONSTRUCTION GUIDELINES 1.01 Introduction: 1.01.1 Historical ilackeround: These standard rockery construction guidelines have been developed in an effort to provide a more stringent degree of control on rockery materials and construction methodology in the Pacific Northwest. They have been assembled from numerous other standards presently in use in the area, from expertise provided by local geotechnical engineers, and from the wide experience of the members of the Association of Rockery Contractors (ARC). 1.01.2 Goal: The primary goals of this document are to standardize the methods of construction for rockeries over four feet in height, and to provide a warranty for the materials used in construction and the workmanship employed in construction. This standard has also been developed in a manner that makes it, to the best of ARC's knowledge, more stringent than the other standards presently in use by local municipalities. 2.01 Materials: 2.01.1 Rock °utility: All rock shall be sound, weathering resistant, angular ledge rock. The longest dimension of any individual rock should not exceed three times its shortest dimension. Acceptability of rock will be determined by laboratory tests as hereinafter specified, geologic examination and historical usage records. All rock delivered to and incorporated in the project shall meet the following minimum specifications: a. Absorption Not more than 2.0% for igneous and metamorphic rock types. Not more than 3.0% for sedimentary rock types. b. Accelerated Expansion (15 days) (CRD -C -148) *1, *2 Not more than 15% breakdown Not greater than 5% loss c. Soundness (MgSO4 at 5 cycles) (CRD -C -137) . d. Unconfined Compressive Strength Intact strength of 15,000 psi, or greater for igneous and ASTM D 2938 -79 (reapproved 1979) metamorphic rocks, and 8000 psi or greater for sedimentary rock. *1. The test sample will be prepared and tested in accordance with Corps of Engineers Testing procedure CRD -C- 148, "Method of Testing Slone for Expansive Breakdown on Soaking in Ethylene Glycol." Test requirements of not more than 15 percent breakdown will be computed by dividing the number of individual pieces of initial sample suffering breakdown (that is, separating into two or more pieces) by the total number of initial pieces in the sample. *2. Accelerated expansion tests should also include analyses of the fractures and veins found in the rock. Many problems associated with rockery failures are related to the rock fractures and veins found within the rock and not the rock itself. 4/4/89 Page 1 1 Geotechnical Consultation Services 90 -1081 Questar Commerce Center - Building 2 Rockery July 24, 1990 Page F Unfortunately, it is difficult, if not impossible, to achieve th;z form of contact in rockery construction. As a result, it is often possible for soil particles to be flushed from the face of the soil into the fabric. Over time, and this is often a short period, large portions of the fabric become clogged and this, coupled wit.'. subsurface seepage, can lead to buildup of hydrostatic pressure behind the rockery. Naturally, the rockery cannot withstand such pressures, and it moves and /or fails. In our opinion, this scenario can generally be avoided if the filter rock material is placed careful:: - so that the soil face is suitably protected. Construction Monitoring Because rockery construction is a craft, and one that it is so heavily dependant on the contractors staff and equipment, it is imperative that the construction process be monitored periodically throughout. By so doing, it is possible for us to verify that the recommendation: contained in this letter and the ARC Standard Guidelines are being followed, that the rock•is suitable, and the construction procedure appropriate. It also provides an opportunity to make modifications to the recommendations in the field should unexpected conditions be encountered. This avoids hindering the schedule and helps keep the project within budget. Your contractor has indicated that he expects the rockery construction to take approximately seven to ten working days to complete. Based on this schedule, we estimate that a visit of relatively short duration should be made every other day. This should result in about three to four visits to the site. At each visit a Rockery E:;aminati Record sheet will be completed summarizing the progress and the quality and form of construction. Following completion of the rockery, a written summary report will be provided to you and the City of Tukwila. Copies of the Roc•:e y Examination Records will be attached for your information. C1 osure • The recommendations contained iii this letter pertain to t'ae rockery and are for the exclusive use of Capital Consultants and other consultants only. The recommendations have been made in manner. consistent with that level of .are and skill ordinarily Geotechnical Consultation Services 90 -1081 Questar Commerce Center - Building 2 Rockery July 24, 1990 Papa 9 exercised by other members of the profession currently practicing under similar conditions in this area. No other warranty is expressed or implied. Providing the recommendations contained in this letter and the 7'RC Standard Guidelines are closely followed during construction, and the. construction process is monitored, the completed rockery sh, :.;:d function as required for the lifetime of the project. We trust this information is sufficient to allow you to proceed with construction. Should you have any questions about any point in this letter or the ARC Guidelines, please call. Very truly yours, CREATIVE ENGINEERING OPTIONS, INC. Glen Mann, P.E. President c.c. Ms. Melisse Dynan; Pacific Cities Attachment: ARC Standard Rockery Construction, Guidelines Sheet 1 of 3, Rockery Location Sketch Sheet 2 of 3, Option 1 Rockery - Section Sheet 3 of 3,. Option 3 Rockery - Section 1 2.01.2 Frequency of Testing: Quarry sources for rockery rock shall begin a testing program when either becoming a supplier or when a new area of the source pit is opened. The tests described in Section 2.01.1 shall be performed for every four thousand (4000) tons for the first twelve thousand (12000) tons of material blasted and removed to establish that specific rock source. The tests shall then be performed once a year or at an apparent change in material. If problems with a specific area in a pit or with a particular material are encountered, the initial testing cycle shall be restarted. 2.013 Rock Density: Recognizing that numerous sources of rock exist, and that the nature of rock will vary not only between sources but also within each source, the density of the rock shall be greater than one hundred fifty - five (155) pcf. Typically, rocks used for rockery construction shall be sized approximately as follows: Mock Size Small to large one man Small to large two man Small to large three man Small to large four man Five Man Six Man Rock Weight 50 -200 pounds 200 -700 pounds 700 -2000 pounds 2000 -4000 pounds 4000 -6000 pounds 6000 -8000 pounds Two and one -man rock, and sometimes smaller, are often used to fill surface gaps along the top of the completed rockery to create an aesthetically pleasing surface. This is an acceptable practice provided none of the events described in Section 3.01.5 occur, and that the owner prevents people from climbing or walking on the completed rockery. In rockeries over eight feet in height, it should not be possible to move the large sized rocks (four to six-man size) with a prybar. If these rocks can be moved, the rockery should not be considered capable of restraining any significant lateral load. However, it is both practical and even desirable that smaller rocks, particularly those used for "chinking" purposes, can be moved with a prybar to achieve the "best fit ". 2.01.4 Submittals: The rock source shall present current geologic and test data for the testing for the minimum guidelines described in Section 2.01.1 on request by either the rockery contractor, the client, or the applicable municipality. 3.01 Rockery Construction: 3.01.1 General: Rockery construction is a craft and depends largely on the skill and experience of the builder. ' A rockery is a protective system which helps to retard the weathering and erosion process on an exposed cut or fill soil face. While by its nature (the mass, size and shape of the rocks) it will provide some degree of reten- tion, it is not a designed or engineered system in the sense a reinforced concrete retaining rockery would be considered designed or engineered. The degree of retention achieved is dependant on the size of rock used; that is, the mass or weight, and the height of the rockery being constructed. The larger the rock, the more competent the rockery. To accomplish this, all rockeries in excess of four feet in height should be built on a "mass" basis. To provide a competent and adequate rockery structure, all rockeries constructed in front of either cuts or, fills in excess of tight feet in height should be bid and constructed in accordance with these standard guidelines and the gcotcchnical engineers supplemental recommendations, Both the standard guidelines and the supplemental gcotcchnical recommendations should be provided to prospective bidders before bidding and the start of construction. 4/4/89 Page 2 The same geotechnical engineer should be retained to monitor rockery construction and to verify, in writing, that the rockery was constructed in general accordance with this ARC standard and with his supplemental recommenda- tions, in a professional manner and of competent and suitable materials. 3.01.2 Geotectrnicnl Enttineer: The geotechnical engineer retained to provide necessary supplemental rockery construction guidelines shall be a practicing geotechnical /civil engineer licensed as a professional civil engineer in the State of Washington who has at least four years of professional employment as a geotechnical engineer in responsible charge, including experience with fill construction and stability and rockery construction. The geotechnical engineer should be hired either by the rockery contractor or the client. 3.013 Responsibility: The ultimate responsibility for rockery construction should remain with the rockery builder. However, rockeries protecting moderate to thick fills, with steep sloping surfaces above or below them, with multiple steps, with foundation or other loads affecting them, protecting sandy or gravelly soils subject to ravelling, with seepage or wet conditions, or that are more than eight feet in height, all represent special conditions and require consultation and /or advice from qualified experts. 3.01.4 Workmanship: All workmanship is guaranteed by the rockery contractor and all materials are guaranteed by supplying quarry for a period of six years from the date of completion of erection, providing no modification or changes to the conditions existing at the time of completion are made. 3.01.5 Changes to Finished Product: Such changes include, but are not necessarily limited to, excavation of ditches or trenches within a distance of less than 1.5 times the rockery height measured from the toe of the rockery, removal of any material from the subgrade in front of the rockery, excavation and /or removal of material from any location behind the rockery within a distance at least equal to the rockery's height, the addition of any surcharge or other loads within a similar distance of the top of the rockery, or surface or subsurface water forced, directed, or otherwise caused to flow behind the rockery in any quantity. 3.01.6 Stones: Slopes above rockeries should be kept as flat as possible, but should not exceed 2:1 (Horizon - tal:Vertical) unless the rockery is designed specifically to provide some restraint to the load imposed by the slope. Any slope existing above a completed rockery should be provided with a vegetative cover by the owner to help reduce the potential for surface water flow induced erosion. It should consist of a deep rooted, rapid growth vegetative mat and typically will be placed by hydroseeding and covered with a mulch. It is often useful to overlay the seed and mulch with either pegged in -place jute matting, or some other form of approved geotechnical fabric, to help maintain the seed in -place until the root mat has an opportunity to germinate and take hold. 3.01.7 Monitoring: All rockeries constructed against cuts or fills in excess of eight feet in height shall be periodically monitored during construction by the geotechnical engineer to verify the nature and quality of the materials being used are appropriate, that the construction procedures are appropriate, and that the rockery is being constructed in a generally professional manner and in accordance with this ARC standards and any supplemental recommendations. On completion of the rockery, the geotechnical engineer shall submit to the client, the rockery contractor, and to the appropriate municipality, copies of his rockery examination reports along with a final report summarizing rockery construction. 3.01.8 Fill Comnnction: Where rockeries are constructed in front of a fill, it is imperative that the owner ensure the fill be placed and compacted in a manner that will provide a competent fill mass. To achieve this goal, all fills should consist of relatively clean, organic and debris free, granular materials with a maximum size of four inches. Ideally, but particularly if placement and compaction is to take place during the wet season, they should contain no more than five percent fines (silt and clay size particles passing the number 200 mesh sieve). All fills should be placed in thin lifts not exceeding ten inches in loose thickness. Each lift should be compacted to at least 95 percent of the maximum dry density, as determined by ASTM Test Method D- 1557 -78 (Modified Proctor), before any additional fill is placed and compacted. In -place density tests should be performed at random locations within each lift of the fill to verify this degree of compaction is being achieved. 4/4/89 Page 3 3.01.9 frill Construction and Reinforcement: There are two methods of constructing a fill against which to build a rockery. The first, which typically applies to rockeries of Icss than eight feet in height, is to overbuild and then cut back the fill. The second, which applies to all rockeries in excess of eight feet in height, is to construct the fill using a geogrid or geotechnical fabric reinforcement. Overbuilding the fill allows for satisfactory compaction of the fill mass out beyond the location of the fill face to be protected. Overbuilding also allows the earthwork contractor to use larger and more effective compaction equipment in his compactive efforts, thereby typically achieving a more competent fill mass. Cutting back into the well compacted fill also typically results in construction of a competent near vertical fill face against which to build the rockery. For the higher rockeries the use of a geogrid or geotechnical fabric to help reinforce the fill results in construction of a more stable fill face against which to construct the rockery. This form of construction leads to a longer lasting and more stable rockery and helps reduce the risk of significant long term maintenance. This latter form of construction requires a design by the geotechnical engineer for each specific case. The vertical spacing of the reinforcement, the specific type of reinforcement, and the distance to which it must extend back into the fill, and the amount of lapping must be determined on a rockery-by- rockery basis. 3.01.10 Rockery Keyway: The first step in rockery construction, after general site clearing and /or general excavation, is to construct a keyway in which to build the rockery. The keyway shall comprise a shallow trench of between twelve (12) and eighteen (18) inches in depth, extending for the full length of the rockery, and inclined back slightly towards the face being protected. It is typically dug as wide as the rockery (including the width of the rock filter layer). If the condition of the protected face is of concern, the keyway should be constructed in sections of manageable length, that is .of a length that can be constructed in one shift or one days work. The competency of the keyway subgrade to support the rockery shall be verified by probing with a small diameter steel rod. The rod shall leave a diameter of between three - eights and one -half inch, and shall be pushed into the subgrade in a smooth unaided manner under the body weight of the prober only. Penetration of up to six inches, with some difficulty, shall indicate a "competent" keyway subgrade unless other factors in the geotechnical engineer's opinion shall indicate otherwise. Penetration in excess of six inches, or of that depth with ease, shall indicate a "soft" subgrade and one that could require treatment. Soft areas of the subgrade can be "firmed up" by tamping a layer of coarse quarry spalls into the subgrade. 3.01.11 Keyway and Rockery Drainage: On completion of keyway excavation, a shallow ditch or trench, approxi- mately twelve (12) inches wide and deep, should be dug along the rear edge of the keyway. A minimum four - inch diameter perforated or slotted ADS drain pipe, or equivalent approved by an engineer, should be placed in this shallow trench and should be bedded on and surrounded by a free- draining crushed rock. Burial of the drain pipe in this shallow trench provides protection to the pipe and helps prevent it from being inadvertently crushed by pieces of the rockery rock. This drain pipe should be installed with sufficient gradient to initiate flow, and should be connected to a positive and permanent discharge. Positive and permanent drainage should be considered to mean an existing, or to be installed, storm drain system, a swale, ditch or other form of surface water flow collection system, a detention or retention pond, or other stable native site feature or previously installed collection system. 3.01.12 Rockery Thickness: The individual rockery thickness, including the rock filter layer, should be at least 40 percznt of the rockery height. Unless otherwise specified in writing by the rockery "designer" the individual rocks should be arranged in a single course which, when measured to include the filter layer, is equal to the required rockery thickness. 4/4/89 Page 4 3.01.13 Rock Selection: The contractor should have sufficient space available so that he can select from among a Number of stockpiled rocks for each space in the rockery to be filled. Rocks which have shapes which do not match the spaces offered by the previous course of rock should be placed elsewhere to obtain a better fit. Rock should be of a generally cubical, tabular or semi - rectangular shape. Any rocks of basically rounded or tetrahedral form should be rejected or used for filling large void spaces. Smaller rocks (one to two -man size, or smaller) are often used to create an aesthetically pleasing "top edge" to a rockery. This is acceptable provided none of the events described in Section 3.01.5 occur, and that people are prevented from climbing or walking on the finished rockery. This is the owner's responsibility. 3.01.14 Rock Placement: The first course of rock should be placed on firm unyielding soil. There should be full contact between the rock and soil, which may require shaping of the ground surface or slamming or dropping the rocks into place so that the soil foundation conforms to the rock face bearing on it. As an alternative, it is satisfactory to place and tamp crushed rock into the subgrade to tighten it up. The bottom of the first course of rock should be a minimum of twelve (12) inches below the lowest adjacent site grade. As the rockery is constructed, the rocks should be placed so that there are no continuous joint planes in either the vertical or lateral direction. Each rock should bear on at least two rocks below it. Rocks should be placed so that there is some bearing between flat rock faces rather than on joints. Joints between courses should slope downward towards the material being protected (away from the face of the rockery). 3.01.15 Face Inclination: The face of the rockery should be inclined at a gradient of about 1:6 (Horizontal: - Vertical) back towards the face being protected. The inclination should not constructed flatter than 1H:4V. 3.01.16 Voids: Because of the nature of the product used to construct a rockery, it is virtually impossible to avoid creating void spaces between individual rocks. However, it should be recognized that voids do not necessarily constitute a problem in rockery construction. Where voids of greater than six inches in dimension exist in the face of a rockery they should be visually examined to determine if contact between the rocks exists within the thickness of the rockery. If contact does exist, no further action is required. However, if there is no rock contact within the rockery thickness the void should be "chinked" with a smaller piece of rock. If a void of greater than six inches exists in the rear face of the rockery, it should be "chinked" with a smaller rock. 3.01.17 Filter Laver: In order to provide some degree of drainage control behind the rockery, and as a means of helping to prevent loss of soil through the face of the rockery, a drainage filter shall be installed layer between the rear face of the rockery and the soil face being protected. This filter layer should be at least twelve (12) inches thick; and for rockerys in excess of eight feet in height, it should be at least eighteen (18) inches thick. It should be composed of four inch minus crushed rock, or other material approved by the geotechnical engineer. If one of the rockery rocks extends back to the exposed soil face, it is not necessary that the filter rock layer extend between it and the soil face. In the event seepage is encountered emanating from a protected face, we recommend the use of a well - graded filter layer. We do not recommend the use of a geotechnical fabric for other than coverage of relatively small and isolated seepage areas because it has been the industry's experience that the filter fabric tends to clog rapidly. This quickly leads to a buildup of hydrostatic pressure which can subsequently cause failure and collapse of the rockery and is to be avoided. This clogging is apparently due to the virtual impossibility of achieving full contact between the soil face, fabric and rock filter material. If full surface contact cannot be achieved, there is often a tendency for the soil materials to flush from the protected face into the "pockets" in the fabric which leads to the aforementioned clogging. 4/4/89 Page 5 3.01.18 Surface Drainage: It is the owner's responsibility to intercept surface drainage from above the rockery and direct it away from the rockery to a positive and permanent discharge well below and beyond the toe of the rockery. Use of other drainage control measures should be determined on a case -by -case basis by the geotechnical engineer prior to bidding on the project. Page 6 • LEGEND Crushed rock filter material ranging between 4 and 11/2 inches in size and free of organics, with less than 5 percent fines (silt and clay size particles passing the No. 200 mesh sieve). Compacted structural fill consisting of free - draining, organic -free material with a maximum size of 4 inches. Should contain no more than 5 percent fines (described above), compacted to at least 95 percent of ASTM D- 1557 -78 maximum density. _ Tenser SS -1 geogrid, Mirafi, or equivalent reinforcement approved by geotechnical engineer. OPerforated or slotted drain pipe with 4 inch minimum diameter bedded on and surrounded by crushed rock filter material, described above. ® Designates size of rock required, i.e. 4 man. NOTES • All fill should be placed In thin lifts not exceeding 10 inches in loose thickness. Each layer should be compacted to no less than 95 percent of maximium dry density, as determined by ASTM D- 1557 -78 (Modified Proctor), • With exception of upper layer, geofabric reinforcement should be wrapped around exposed fill face and lapped back beneath overlying fill layer a distance of at least 2 feet. • Thickness of crushed filter rock layer, B, should be no Tess than 18 inches, • Depth of burial of basal layer of rock, D, should be no less than 18 inches. • Length of reinforcing geofabric, Lfl, shall be feet. • Geofabric reinforcement layer spacing Z, and Z2, shall be and feet, respectively. • Height of rockery, H, should not exceed feet. TYPICAL DETAIL FILL CONSTRUCTION ROCKERY MORE THAN 8 FT. HEIGHT. LEGEND Crushed rock filter material ranging between 4 and 11/2 inches In size and free of organics, with Tess than 5 percent fines (slit and clay size particles passing the No. 200 mesh sieve). Compacted structural fill overbuild. Compacted structural fill consisting of free - draining, organic -free material with a maximum size of 4 inches. Should contain no more than 5 percent fines (described above), compacted to at least 95 percent of ASTM D- 1557 -78 maximum density. OPerforated or slotted drain pipe with 4 Inch minimum diameter bedded on and surrounded by crushed rock filter material, described above. 0 Designates size of rock required, i.e. 4 man. rard t *iii• NOTES • All fill should be placed in thin lifts not exceeding 10 inches In loose thickness. Each layer should be compacted to no less than 95 percent of maximum dry density, as determined by ASTM D- 1557.78 (Modified Proctor). • Thickness of crushed filter rock layer, B, should be no Tess than 18 Inches. • Depth of burial of basal layer of rock, D, should be no Tess than 18 inches. • Height of rockery, H, should not exceed feet. TYPICAL DETAIL FILL CONSTRUCTION ROCKERY 8 FT. AND LESS IN HEIGHT. Proj. No Drwn. Checked Dated Plate Fig. A, ROCKERY SECTION Fig. B. ROCKERY ELEVATION SCHEMATIC ONLY -- NOT TO SCALE NOT A CONSTRUCTION DRAWING NOTES: Rockery construction is a craft and depends largely on the skill and experience of the builder. A rockery is a proteptive system which helps retard the weathering and erosion process on an exposed soil face. While by its nature (mass, size and shape of the rocks) it will provide some degree of retention, it is not a designed or engineered system In the sense a reinforced concrete retaining wall would be considered designed or engineered. The degree of retention achieved Is dependent on the size of the rock used; that is, the mass or weight, and the height of the wall being constructed. The larger the rock, the more competent the rockery should be. Rockeries should be considered maintenance items that will require periodic Inspection and repair. They should be located so that they can be reached by a contractor if repairs become necessary. Maximum Inclination of the slopes above and behind rockeries should be 2:1 (Horizontal:Vertical). Minimum thickness of rock filter layer B.12 inches. Minimum embedment D -12 inches undisturbed native soil or compacted fill placed in accordance with report recommendations. Maximum rockery height H A feet. Rockeries greater than 8 feet in height to be installed under periodic or full time observation of the geotechnlcal engineer. Unless otherwise specified in writing by the rockery "designer," all rocks placed in the lower two-thirds of the wall should be 5 to 6 man rock, 4000 lbs. or larger. Rocks placed above this level should gradually decrease in size with increasing wall height using 3 to 5 man rock, 700 to 6000 lbs, The long dimension of the rocks should extend back towards the cut or fill fence to provide maximum stability. Rocks should be placed to avoid continuous Joint planes in vertical or lateral directions. Each rock should bear on two or more rocks below it, with good flat -to -flat contact. All rockeries over 4 feet in height should be constructed on basis of wall mass, not square footage of face. Approximate Approximate Size Weight - lbs. Diameter 1 Man 2 Man 3 Man 4 Man 5 Man 6 Man 50.200 200-700 700 -2000 2000-4000 4000 -6000 6000 -8000 12.18" 18 -28" 28-36" 36-48" 48-54" 5450" Reference: Local quarry weight study using average weights of no less than six rocks of each man size conducted in January, 1988. LEGEND: ±ar r41„rY ltl 0 Drainage materials to consist of clean angular well- graded quarry spells, with 4 -inch maximum size, or other material approved by the geotechnlcal engineer. Surface seal; may consist of impervious soil or a fine tree draining granular material. Undisturbed firm Native Soil. Drain pipe; 4 -Inch minimum diameter, perforated or slotted rigid plastic ADS pipe laid with a positive gradient to discharge under control well away from the wall. Pro). No. Drwn. Date TYPICAL ROCKERY DETAIL NATIVE CUT, ANY HEIGHT OVER 4 FT. Checked Date SEQUENCE OF EVENTS FOR CONSTRUCTION OF CRIBLOCK RETAINING WALL. 1. Remove the existing rockery. 2. Excavate the footing for the CRIBLOCK retaining wall. The footing is prepared on a 1:4 batter. 3. Begin laying the base of the wall onto the native, dense material. 4. The wall is constructed in 2 1/2 foot vertical lifts. All backfill and drain material is placed and compacted. Then another lift is constructed, repeating the process until the wall is completed. 5. The backslope behind the wall is graded to meet the design specifications. 6. The wall face and the slope behind the wall are planted as specified in the drawings. , er.t. -1 .;:.Z...??.t‘,44ii.? :x DATE; iC�ll t Design Edgo Services, Inc. I 1520 S.F., gnimont /$i.►ite 330 Por tland, Orogon 97215 4S03) 238 -1112 Pt,csimile Tranamlt►sian Cover Street 'Ax MO. 'T'O: p T,..1r..v104,,, AJ.-, ....�r`7NVIFx••t >i,ptll is ..i-..► S FROM : it •.. r1;narent ('poss.-0..p. (.1?.).7•11:1.t,.. 'IP ci(1h 9( Quil JErittinot lY4,11,►1 • r et4 et,) r ^. k..isrcJ all 4011L1 . Pages to follow r.!►ver sheaLi_.__.L... I f Any pars war not recoivod or titers are Any questions, ,plead° inri r :eta voice radpones or call as soon (.0 pn':sible. r;ommcnt s S 1'h] V11t;s1 Q./: 1 a" lotl /Vil r► h t $ 1l" /n., /p 1 9 1 e t.) / ' ttt er. 1`\ \levy. rel wll % vt al 4.1.. w9 I) tksiS��•, Jo)), qi.J ci ci 81110,4 1 11-491' "1.1014 tr t i( ri ILA I c�tl a �rv�As�'� �y1,1"1\ + fly., T,ep fit,,, ,.,„111 ktiJ t. clove( ..4 y t // ;;le:hI'1 Mnriti , 11 I -kg vt (.la,,h Mom rit,tel.) `P11r 10 3 e 1, 14 c-.'t istl“ MY' p 1/4C 11 s r �as Alk/i e t?, . i O a ►t tt d Aivtc armor a t I,. �lril« 4.)1 t 10p 04100 tf) •Pta osign 139 geiv,isye m, Inc, 1 .!.w.RYM.014,4/1 WW. M4. w. M.. wr. n. w NNu. ��. �AM.pY1.YWNMWew...ur..•......., ,.. .... I.1 N I '11 :t 1I � ;_ is o. LSws fir. FtN_ h' — 2./6 .2,00 02,241 4 s: lit S '1,R2 1,93 .2841 4 86 11 :3 8 - 0.73 2.4c) .;Vt/c. / 778 ;2 IZ' 3.37 :R.11 :Z124 14.4 a 73 60 ;77 1175;6'3 15- ; ... 3 12� 3, 29 3,04 1:--,K51--.2] 2g40 1 15 ; + 1s 1,46 3,8s 913r 3p6 ?. MOO) t lr,I-Du !ict k L fl C�H I I t I_1 _ _I _ .L'i L. _ • S'+: v 1 I_ h ._ Design Edge Services, Inc. 4520 S,E, Belmont /Suite 330 Portland, Oregon 97218 cd$ # Facsimile Transmission Cover Sheet TO: ,ANI) FROM: 'L PROJECT: OtSTAa. (274717.S. FAX NO. ^�.1a3',.g( (803) 238.1)12 CONCERNING: T;LA0,04T 7✓131(obt--, Pages to•follow cover sheets. If any pages were not received or there are any questions, please indicate voice response or call as soon as possible. comments: Denoty, C. rectliVe- 1 tnt:W P1. Op 1 w,a. (»t 1-)y,t 64 art &.e. SOY is e i vte 1-e vreev x tie r � )r � 101 /4%rq Q4. i lra/,(7/0? �7 .1le "froj'ec./ V), ifte7 I 4 q)1rs a op ivetedj Ina / Esc rtrce.,-e. Design Edge Services, Inc. Signed _ //' .. PRELIMINARY CRIBLOCK RETAINING WAWA DESIGN CRITERIA DATE W2 I /91 PROJECT NAME CCl41.kg PROJECT NUMBER 2 /0 I� 447 T_? SOIL DENSITY SOIL, INTERNAL ANGLE OF FRICTION EQUIVALENT FLUID PRESSURE ALLOWABLE SOXL BEARING PRESSURE METHOD OF ANALYSIS 300 3000 P ;:i This 1s a preliminary analysis and 1s not to be used for construction, not consider stability of the soil beyond the interface of the soil and verified by a Professional Soils Consultant, Results of this review to for construction. This analysis includes retaining wall stability only, it does the wall. The above criteria and loading conditions are to be be delivered to Design Edge Services, Inc., prior to release NATIVE LltJDISTURSEP Soy L ptlAIPJAG& SYSTEM BY oTh &i1S AJ A L r. / _.r • • 4 DATE PROS ECT NAME G.) L� S jAIZ G E kJ re PROJECT NUMBER 324_ The following ate preliminary wall configurations and are to be used for construction, _ Eta_..... _JO._ _. E, ts. Sp.....ii.9] l 1 1 ` 141 2,31 z7 go 70S- 1.22 �Y 3' 6 2,2% oo 663 1 / +. 141 z 3.70 ac;t I2xo2 11: I s I 3,10 3,31 z4.11 24 s,3 F Criblockr ,,_ tabling Walls SOLUTIONS FOR EARTH RETENTION 02276 CRI BuyLine 4702 �i f Since its introduction to the United States over a decade ago, Criblock has gained nationwide acceptance and has con- structed walls from coast to coast. Over 1 million square feet was erected in 1988 alone. An interlocking, modular system, Criblock offers versatility in the application area as well as being a cost effective solution to your retaining wall needs. Using component technology, the Criblock system can pro- duce dramatic and imaginative results. Curves, angles, tiers or steps, the only limit is the designers imagination. From design to manufacture to construction, Criblock is a leader in the earth retention industry. 6" I 6' 10 -i - -i 17- 9.5" I FALSE HEADER 10" 0- 3' . i 3' HEADER T7,, FRONT STRECTHER 6" -I -1 I I BACK STRECHER 4' -6" HEADER 3, -9„ { CLOSED FACE PANEL 2' -7.5" .esi ...n Services SURCHARGE SLOPE ANGLE VARIES ..,\ i rrr STRECCHER (nP) i .4' -6 "HEADER i '" t (nP) !r FALSE u 110.61r10 HEADER i '' to‘I'MOnULE Q is1.11•11116 1-c' M 7r6 BACK STRETCHER W SINGLE DEPTH WALL Z DOUBLE DEPTH WALL 2 W TRIPLE DEPT W ALL -----"1 'EMBEDMENT (WIN) 2 FALSE HEADER FRONT STRECHER 4' -6" HEADER BACK STRETCHER In -house engineering capabilities allow Criblock to provide assistance at all phases of a project. Preliminary feasibility studies, cost estimates, plans, specifications, and construction detail drawings all contribute to the ability to carry a reten- tion need from concept to completed structure. The precast Cribicu r<t,o rust, •trr, nt,tnnt,rr, d dry -pack rneth(,(I c,rrrenor ,inci v ,!`r' nl,fln- tarned through ti u• ,r,r of foil∎ dui( ,n dttgl n,,rt huuv, A kircr,n inscvltury kept un h,lnri tr, tm,.rcit. ,t r,tpui rt,,,pur-,r• twie for c on"Uuc t ( r yck. We have a full staff of construction crews who use Criblock's component technology, and a philosopy of "one man, one block" k) construct an extremely cost efficient retaining wall in a minimum number of days, Because of their a,,.thetic bards( aping r ox,ilk .are being used more and more in various highway ,applir atuua�. The design flexibility afforded by crihwalls allows for both vertical and battered wall designs. Vertical crihwalls are most commonly used when there is limited right -of -way in which to place the wall. Typically, these walls utilize a closed face panel inserted inside the front of the wall to retain the soils within the wall. Several installations have made use of an acrylic rotor- coating applieri try the surface of the finished wall for ardtiter tuna! continuity with surrounding structures. lications When designed in consultation with a geotechnical engineer, Criblock retaining walls offer one of the most ver- satile and cost effective earth retention methods available for water applications. The precast, modular units can be con- structed in otherwise inaccessible locations. The simplicity of the system requires a minimum of heavy equipment. Numerous methods have been successfully used to prevent scouring of the face of the wall. Precast closure panels can be inserted into the front of the wall in areas where heavy water flow is encountered. Where flow rates allow, wire mesh can be placed in the front of the cells in lieu of the panels. When combined with a rock backfill and filter fabric, both of these methods have proven to be extremely versatile designs. 4 AmnonI ■ 1'"�'1�1 II = Ir- -r =I.— 1.--- I Because Criblock is an interlocking, modular system it is ideally suited for use on these higher, cut walls. Criblock re- taining walls do not require temporary shoring in most cut applications. The interlocking, modular crib components offer the advantage of the "slot -cut" method of construction. Slot- cutting eliminates the need for temporary shoring and requires no special equipment or conditions. The "slot- cutting" process involves the use of deep, but shorter cuts to provide the grades needed for wall construc- tion. When done under the supervision and direction of a qualified soils engineer, these short but deep cuts do not undermine the stability of the slope being excavated. Slot - cutting is done in phases that include both excavation and wall construction. The initial phase usually involves making a 50 -70 foot cut at one end of the wall. This cut resembles a sort of notch with a steep backslope. Criblock wall is then stacked and backfilled within this "slot" in a pyramid fashion. (See diagram "A ") Once the toe of the excavation has been stabilized with crib - wall, then another 40-50 feet of excavation is opened up. Each slot is stabilized with completed cribwall before the next is cut. Successive cuts allow earlier portions of the crib - wall to be topped out to finished grade elevations. 50' 1st OPEN CUT -NN • 2 ��,rw■ • 1.:�,,;�. ��1� 02276 CR! • f- f�� mm1 °l -gym- BuyLine 4702 /ff�ll�4l. • 25' 2nd OPEN CUT 1st CONSTRUCTION TYPICAL "SLOT CUT" CONTRUCTION PROCEDURE: 1) IMMEDIATELY AFTER 2nd CUT, AREAS A AND 13 ARE OPEN. 2) AFTER 1st CONSTRUCTION 15 COMPLETED, AREA B 15 OPEN. 3) NEXT STEP IS TO MAKE 3rd CUT, RESULTING IN AREAS 13 AND C BEING OPEN. THE 2nd AND 3rd CONSTRUCTION SHOULD PROCEED. 2nd CONSTRUCTION 3rd CONSTRUCTION NOTES: 1) 25' & 50' "SLOTS" ARE SHOWN ABOVE. ACTUAL LENGTH CAN VARY, AND MUST BE AS SPECIFIED BY SOIL ENGINEER. 2) STEPS IN WALL ALONG TERMINAL EDGE OF EACH CONSTRUCTION SEQUENCE CAN VARY IN CONFIGURATION (STEEPER OR SHALLOWER). 3' -0" HEADER EMBEDMENT SCALE: 1" - 6" FRONT STRETCHER FALSE HEADER OF REQUIRED) STEP OPTION .p■ CONCRETE 4' -6" HEADER PAD VERTICAL OPTION 5 Noise pollution has become one of the foremost concerns of roadway and commercial planners. The effect of noise on existing residential areas has become a major issue in many urban areas. The Sound Barrier uses the Criblock system's inherent qualities of quick construction and noise deadening face to address the need for a cost effective, sound atten- uation system. The Sound Barrier has been tested, using a FHWA perfor- mance model, to average an insertion loss (the difference in sound levels before and after the barrier is installed) of 17.5 dBA. Criblock engineers each cribwali for optimum design. The need for multiple depths depends upon several factors such as: wall height, type of surcharge and specific soils con- ditions. The number of wall depths is then adjusted to guarantee proper factors of safety for sliding and overturning, and to distribute the weight of the wall over a base width acceptable to the specific bearing capacity of the site material. In addition to varying the number of crib depths used, the height of each depth is adjusted to offer the most efficient use of the crib material and to distribute the weight of the struc- ture optimumly between the toe and the heel of the wall. For example, a wall 25 feet high might break out to require 15 feet of single depth, 6 feet of double, and 4 feet of triple depth. �°•� • ,� •� v rsr.4 P a 3t 1.+.��. -. 7... �r ^�..r ,~~„� ^tea . w Perhaps one of the most unique feature advantages of the Criblock system is the aesthetic value of being able to land- scape the face of the cribwali. The open cells that compose the face of the wall readily lend themselves to various land- scaping concepts. Because the wall is typically built on a batter of 4:1 (vertical:horizontal) the sloped face of the wall retains the recompacted soils at a slope condusive to sup- porting plant life. The battered face of the wall also simplifies the irrigation design should irrigation be called for, Criblock walls can be landscaped in almost any climate. Typically, native plant varieties that require little or no ad- ditional irrigation are used. Planting of the wall face is usually accomplished by "hydro-seeding" and /or handplanting 6 schemes that can include multiple growth stages that may allow for heartier, rapid growth plants to fill in during the initial stages while the more colorful plants have time to take root and develop. Numerous landscaping themes have been successfully used in cribwalls. These themes require that various constraints be considered, such as: walls in highly visable locations requiring colorful and dense growth; walls for highway projects that must utilize native plant varieties but cannot be irrigated; plantings that are low maintenance for use in areas with limited access; subterranean walls that receive little or no direct sunlite; and plantings designed to endure the rigors of extreme temperatures found at altitudes over 8,000 feet. PART I — SCOPE This Specification sets out requirements for the design, materials, manufacture and construction of pre -cast, reinforced - concrete cribwall systems. 'CRIBLOCKTM' cribwall units are the basis for this specification. 'CRIBLOCKTM' Standard Plan Sheet 1 is incorporated into and made a part of this specification. 1.1 — DESIGN OF WALL SYSTEM: The face of the wall shall consist of a grid of concrete members, with (ace inclined at a slope of 4 vertical to 1 horizontal, or as specifically designed for a particular job. Horizontal members are termed "Front Stretchers." Non - standard stretcher lengths required to complete the end of a wall, are termed "Closers ". The face members shall be connected by transverse members termed "Headers" to a similar grid of "Back Stretch- ers", parallel to the face and located so that the overall thickness of the wall Is not less than 3 feet. Additional spacers between the stretchers in the front and back grids may be used if the system requires it, and are termed "False Headers ", Headers shall be perpendicular to the face of the wall, The system may allow for the addition of one or more grids of members, parallel to the face and situated behind the structure described above, Such additional grids shall be connected to the grid in front of it by an interlocking header system. This constitutes a multiple -depth wall, as detailed on 'CRIB LOCKTM' Standard Plans. The space between the face and the back of the wall shall be filled with free draining rock, or well-compacted soil. The overall stability of the structure when assembled shall be such that this compaction may be carried out without displacing the members. These specifications do not purport to provide a basis for engineering analysis of the overall wall system.'CRIBLOCKTM' Standard Plans furnish some of the basic information used in analyses. A qualified Engineer can provide information as required. PART 2 — MATERIALS 2.1 — CEMENT: Cement shall conform to the requirements of ASTM C 150. Cement shall be either Type II or Type V, depending on ultimate use of product. 2,2. — AGGREGATES: Fine and coarse aggregates shall comply with the requirements of ASTM C 33. Aggregates failing to meet this specification but which have been shown by special test to produce concrete meeting requirements of "QUALITY OF CONCRETE" may be used. 2.3 — WATER: Water shall be potable and free from any substances deleterious to concrete or reinforcement. 2.4 -- ADMIXTURES: Air-entraining admixtures, if used shall comply with ASTM C 260. Chemical admixtures used, shall comply with ASTM C 494. 7 MEW "nom' air • am:imis• BUyLine 4702 2.5 — REINFORCEMENT: Steel reinforcements shall conform to one of the following ASTM stan- dards, as appropriate: A 615, A 616 or A 617. Yield strength of steel shall be 60,000 psi. minimum. The reinforcements shall be free from damage and contamination. 2.6 — CORROSION PROTECTION: Where units are to be used in maritime atmosphere or In direct contact with seawater, reinforcing steel shall be protected against corrosion by hot dip galvanizing at a rate of at least 2 ounces per square foot. The galvination shall be in accordance with ASTM A 123, Alternatives to galvanization to be submitted for approval on a case by case basis, in- clude chemical coating such as SCOTCHKOTE 2.7 - CONCRETE COVER TO REINFORCEMENT: The minimum cover to reinforcing steel shall be 1 -1/4 Inches (See ACI 318 -77, Section 7.72). 2.8 — DRY MIX CONRETE: Concrete for use in the dry-mix press process shall yield an end pro- duct with a minimum concrete compressive strength at 28 days of 3000 psi. and with a surface dry density equal to at least 95% of the density of a unit manufactured by a wet -mix process using the same type and source of aggregates. 2.9 — MANUFACTURE OF UNITS TOLERANCES FOR INDIVIDUAL UNITS: The length and width of all units shall be within ± 1/8 inch of the specified design dimension. 2.10 — FORMED SURFACES All surfaces of units shall have a uniform appearance free from honeycombed areas, 2.11 — TESTING AND INSPECTION: Acceptability of the cribbing units will be determined on the basis of compression tests and visual inspection. The precast units shall be con- sidered acceptable when compression test results indicate strength will conform to 28-day specifications. The contractor or his supplier shall fur- nish facilities and perform all necessary sampling and testing in an ex- peditious and satifactory manner. Units shall be considered acceptable for placement in the wall when 7-day strengths exceed 65% of 28-day requirements. PART 3 — CONSTRUCTION 3.1 — EXCAVATION A bench of excavation to sound material shall be made for the base of the cribwall. Unless shown otherwise on the project plans, the benches shall be horizontal in the line of the wall and have a fall of 1 to 4 from the front to the back of the excavation. The depth of the excavation shall be a minimum of 1.0 feet below the proposed finished ground level at the front face of the wall, or as shown on the project plans. Finished base excavation to within 0.5 inches of base elevation shall include vertical steps where plans indicate base of wall is to step, Unless shown on the plans, a concrete base slab shall not be required. After verification by the Soils Engineer for base -soil adequacy, wall is initiated by placing first course of stretchers directly onto base soil. A maximum of 2 inches of sand or fine gravel may be used for bedding material below the bottom source of stretchers, if the contractor desires. CRIBWALL CONSTRUCTION The cribwall shall be placed in horizontal lifts. No more than 3 lifts shall be placed before backfilling. The units shall be placed in a uniform pattern as shown on the draw- ings or as approved by the Engineer. Walls shall be provided with back stretchers for the full height of the wall, except top course. Refer to 'CRIBLOCKTI Standard Plans. Top course of headers shall consist of full headers only. 3.5 — BACKFILLING MATERIAL: Back(ill material shall consist of either a well - graded crushed rock of at least 1 -inch diameter, or a soil reasonably free from organic and other- wise deleterious materials and conforming to the following gradation limits as determined by AASFITO T -27: Sieve size Percent Passing 3 inches 100 No. 200 10-25 In addition, if the fraction finer than the 4200 mesh sieve is between 15% and 25 %, the backfill must conform to the following requirements. a. The Plasticity Index (P.I.) as determined by AASHTO T -90 shall not exceed 15 unless approved in writing by the Engineer. But in any event shall never be greater than 22. b. The fraction fanner than 15 microns (0.0015 mm) as determined by AASHTO T -88 shall not exceed 15 %. c. The material when compacted to 90% of AASTO T -99 at optimum moisture content shall exhibit an internal angle of friction of not less than 30 degrees as determined in a standard direct shear test. (AASHTO T -236). d. The cohesion as determined by Standard Direct Shear or Triaxle Shear tests shall fall within the range of 50 to 150 psf. Intent of this specification is that backfill material within the wall shall be structurally strong and in addition exhibit sufficient cohesion to effec- tively resist wind and rain erosion, but that cohesion not be so excessive as to create problems with compaction. Wall backfilled with sand need closed faced panels or UV rated filter fabric to prevent erosion, 3.3 — PLACING No more than 2 -1/2 courses of crib framework shall be unfilled before backfill operations begin. Drainage of the areas behind and above the cribwalling should be con- sidered, taking care to insure that drainage is diverted from going over the face of the wall. 3.4 — COMPACTION Unless otherwise specified by soils report, compaction within the crib- bing framework shall be too minimum of 90% relative compaction per the standard proctor. For ingle -depth walls and for the front cell of multiple -depth walls, compaction tests shall be taken at the center of the crib cell, approximately one -third of the distance from back stretcher to front stretcher. For all other cells of multiple -depth walls, tests shall be taken centered in the cell. Minor chipping and cracking of units shall be acceptable with the approval of the Engineer, Criblocle Retaining Walls tQ Southern California 0 Northwest 1531 Grand Avenue 1863 Killarney Way San Marcos, CA 92069 Bellevue, WA 98004 1- 800 - 323 -CRIB 1. 800.323 {RIB 0 Central California 17151 Newhope Street Suite 202 Fountain Valley, CA 92708 1.800. 323 -CRIB 0 Bay Area, California 7080 Donlon Way Suite 212 Dublin, CA 94568 1- 800. 323 -CRIB Southwest Post Office Box 1157 Del Valle, TX 78617 1-800-323-CRIB 512- 389 -0270 Fax 512 - 385 -5462 0 Mid - Atlantic Route 925 North 165 Waldorf, MD 20601 1-800-323-CRIB 0 Southeast 6410 Atlantic Boulevard Suite 125 Norcross, GA 30071 1-800. 272.2742 404-242-1918 Fax 404-368-8051 Q Rocky Mountain 5320 West Quarles Drive Littleton, CO 80123 1-800-727.2600 303.933 -1133 Fax 303 - 933 -3442 Q Northeast A 9 Parker Road Morristown, NJ 07960 1-800-873-CRIB 201 - 285 -5195 Fax 201 - 644-0899 Retaining Walls Northwest, Inc. Lic N MT AI -WN 11501 S D SPEJCAVI#ON OCK FOR: 1299156th Ave, N.E. #L -150 • Bellevue, WA 98007 (206) 747 -0956 • 1-800-877-0956 • Fax (206) 747 -5892 I. SCOPE 2. DESIGN 3. MATERIALS 4. CONSTRUCTION 5. METHOD OF MEASUREMENT AND PAYMENT SCOPE This Specification sets out requirements for the design, materials, manufacture and construction of pre- cast, reinforced concrete cribwall systems. Bidder's attention is called the fact that "CRIBLOCK" cribwall units are the basis for this specification. " CRIILOCK" Standard Design Table & Dimension Packet is incorporated into and made a part of this specification. MI statements and values used in this STANDARD SPECIFICATION are for normal applications and may be changed as required by a qualified engineer. DESIGN The face of the wall shall consist of a grid of concrete members, with the face inclined at a slope of 4 feet vertical to 1 foot horizontal, or specifically designed for a particular job. Horizontal members of such a grid are termed "Front Stretchers ". Where non - standard stretcher lengths are required to complete the end of a wall, they are termed "Closers." The face members shall be connected by transverse members termed "Ileaders" to a similar grid of "Back Stretchers," parallel to the face and located so that the overall thickness of all is not less than 3 feet. Additional spacers between the stretchers in the front and back grids may be used if the system requires it, and are termed "False Headers." Headers shall be perpendicular to the face of the wall. The system may allow for the addition of one or more grids of members, parallel to the face and situated behind the structure described above. Such additional grids shall be connected to the grid in front of it be an interlocking header system. This constitutes a multiple -depth wall, as detailed on "CRIBLOCK" Standard Plans. The space between the face and the back of the wall shall be filled with free - draining rock or well - compacted soil. The overall stability of the structure when assembled shall be such that this compaction may be carried out without displacing the members. A minimum embedment of 1 foot below final grade is required. These specifications do not purport to provide a basis for engineering analysis of the overall wall system. "CRII3LOCK" Standard Plans furnish some of the basic information used in analysis. A qualified engineer can provide information as required. MATERIALS CEMENT: Cement shall conform to the requirements of ASTM C150 and shall be stored and handled so that it is protected against deterioration or contamination at all times. Cement shall be either Type III or Type II depending on the ultimate use of the product. AGGREGATES: Fine and coarse aggregates shall comply with the requirements of ASTM C33. Aggregates failing to meet this specification but which have been shown by special test to produce concrete meeting requirements of "QUALITY OF CONCRETE" may be used. See also "DESIGN MIX." WATER: Water shall be potable and free from any substances deleterious to concrete or reinforcement. ADMiXTURES: Under normal production methods adtnixtures are not used. however, air - entraining admixtures, if used, shall comply with ASTM C260. Chemical admixtures such as water reducing admixtures, retarding adtnixtures, accelerating adtnixtures, water - reduction and retarding admixtures, and water reducing and accelerating admixtures, if used shall comply with ASTM C494. REINFORCEMENT: Steel reinforcement shall conform to one of the following ASTM standards, as appropriate: A615, A616 or A617. Yield strength of steel shall be 60,000 psi minimum. The reinforcement shall be free from damage and contamination. It shall be clean and free from all loose mill scale, dust, loose rust, and coatings such as paint and oil immediately before use in concrete. DESIGN MIX A qualified materials laboratory shall prepare a design specifying relative quantities of cernent, water, aggregate and adrnixtures necessary to obtain required minimum concrete strength and durability. Manufacturer may use his own design mix which has been tested and proven to meet the strength requirernents. This mix design shall be specific to the aggregates in use and shall be available from the manufacturer. QUALITY OF CONCRETE DRY MiX CONCRETE: Concrete for use in dry-mix press process or normal wet -mix process shall yield an end product with a minimum concrete compressive strength at 28 days of 3,000 psi, or 2,400 psi at 7 days. MANUFACTURE OF UNITS TOLERANCES FOR INDIVIDUAL UNITS: The length of headers, stretchers and closer shall be within +/- 1/8 inch of the design value. The width of all units shall be within +/- 1/8 inch of the approved design value. FORMED SURFACES The sides of the units which bear against other units shall be constructed so that the finished units will meet the tolerances specified in "TOLERANCES FOR INDIVIDUAL UNITS" and so that the units may be stripped without damage to the concrete. REINFORCING STEEL PLACING REINFORCEMENT: Reinforcement shall be placed and maintained in the design positions within +/- .50 inch, but without reducing the minimum cover specified. CONCRETE COVER TO REINFORCEMENT: The minimum cover to reinforcing steel shall be 1 -1/4 inches, in accordance with ACI 318. CORROSION PROTECTION: Where units are to be used in maritime atmosphere or in direct contact with seawater, reinforcing steel shall be protected against corrosion by hot dip galvanizing at a rate of at least 2 ounces per square foot. The galvanization shall be in accordance with ASTM A123. Alternatives to galvanizing, to be submitted for approval on a case -by -case basis, include chemical coatings such as SCOTCHKOIE. The above treatment shall be applied only after completion of any and all fabricating processed such as bending and welding. MARKING Each "pallet" of block shall be individually marked with its date of manufacture. Such marking shall be of sufficient durability to withstand a minimum of 12 months exposure to the elements. TESTING AND INSPECTION Acceptability of the cribwall units will be determined on the basis of compression tests and visual inspection. The precast units shall be considered acceptable regardless of curing age when compression test results indicate strength will conform to 28 -day specifications. The contractor or his supplier shall furnish facilities and perform all necessary sampling and testing in an expeditious and satisfactory manner. Units shall be considered acceptable for placement in the wall when 7 -day strengths exceed 65% of 28- clay requirements. ACCEPTANCE OF UNITS ON SITE MI units shall be subject to final acceptance on site. Where the contract includes the construction of the wall, it shall be the contractor's responsibility to ensure that all units are erected in an undamaged condition. The project engineer's representative may carry out such tests or measurements as he /she thinks fit to satisfy himself /herself that the units delivered to the site are equal in quality to the approved design. Where these tests arc of a destructive nature and units prove acceptable, the cost of the units as delivered to the site of testing will be an additional charge to the contract. CONSTRUCTION Cribwall construction shall be in reasonably close conformity to the lines, grades, design and dimensions shown on the plans and as established by the project engineer by means of surveyed staking. EXCAVATION A bench of excavation to sound material shall be made for the base of the cribwall. Unless shown otherwise on the project plans, the benches shall be horizontal in the line of the wall and have a fall or 1 in 4 from the front to the back of the excavation. Finished base excavation to within 0.5 inches of base elevation shall include vertical steps where plans indicate base of wall is to step. CRLOWALL CONSTRUCTION The cribwall units shall be handled and placed in such a manner that no damage is caused to the seating areas. The first course of units shall be stretchers (or closures) unless shown otherwise on the drawings. Care shall be taken in the placement to ensure finn bedding against the base soil. The cribwall shall be placed in horizontal lifts. The cribwall units shall be placed in a uniform pattern as shown on the drawings or as approved by the engineer, Walls shall be provided with back stretchers for the full height of the wall, except the top course. Refer to "CRIBLOCK" Standard Plans. The top course shall consist of full headers only. No back stretchers are required on top course. CORNERS: Where wall join at an angle, it may be necessary to saw -cut stretchers to provide a neatly joined corner. Walls greater than 5 courses high may require special treatment of headers. CURVED WALLS: Where a wall is curved in the plans to a radius of less than 100 feet, saw -cuts will be made where necessary to ensure that the gap between stretchers is uniform. BACKFILLING MATERIAL: Backfill material shall consist of either a crushed rock or a soil reasonably free from organic and otherwise deleterious materials. Backfill material within the wall shall he structurally strong and in addition exhibit sufficient cohesion to effectively resist wind and rain erosion, but that cohesion shall not be excessive as to create problems with compaction. PLACING: Care shall be taken not to disturb the alignment of the units during backfilling and compaction operations. The areas behind and above the cribwall shall be backfilled to the finished configuration shown on the project plans, taking care to insure that drainage is diverted from going over the face of the wall. COMPACTION: Unless otherwise specified by the soils report, compaction within the cribbing framework shall be a minimum of 90% relative compaction per ASTM I)1556. For single -depth walls and for the front cell of multiple -depth walls, compaction tests shall be taken at the center of the crib cell, approximately one -third of the distance from back stretcher to front stretcher. For all other cells of multiple -depth walls, tests shall be taken centered in the cell. EROSION CONTROL Measures must be taken to prevent erosion both during and after construction. Runoff must be channeled or diverted from the backslope of the wall to prevent the surface water from washing out the fill material. This is the responsibility of the owner unless otherwise specified in the contract documents. METHOD OF MEASUREMENT AND PAYMENT Where the contract includes construction of the wall the work will be measured and paid for by the area of the face of the wall (on the slope) measured from the bottom of the base stretcher to the top stretcher. Where the contract if for the supply of units only, payments shall be per unit delivered as ordered. NOTE: SPECIAL INSPECTION REQUIRED It is required, as a condition of these structural calculations, that a member of the Retaining Walls Northwest, Inc. staff field inspect and approve the construction of this cribwall project. Retaining Walls Northwest, Inc. will not accept any responsibility for any cribwall project designed and/or constructed without written final approval from a Retaining Walls Northwest, Inc. staff member. t" Retaining Walls Northwest, Inc. Lic # RET AI -WN 11501 TABLES 1299 156th Ave. N.E. #L -150 • Bellevue, WA 98007 (206) 747 -0956 • 1 -800- 877 -0956 • Fax (206) 747 -5892 DESIGN TABLE SURCHAgGE TOTAL HEIGHT MAXIMUM HEIGHTS (FEE F) WAIL TYPE HI 142 H3 H4 115 Id d 14 14' C•41 12' Id Id Id 19 14 17 I2' 18' 20 15' 15' C•42 gib Id IN I3' Is I' 15' 7' C -42 C -42 13 Id 1r 9' — • - 22 le' 1 1' 3' S' C-43 _ 20' II' II' 7' C-43 22' I r IN ---17- 3 3' 24 1 1' 22 3d 13' IN 10' Id 5' 7' 5' 26' I r 12' 3' 13' Id C• 43 'F 28' 11' 12' 5' 13 10 7' 2' 30' 1 1' 12' 7' 13' Id 7' 4' 32' 11' 12' 9' 1S Id 7' d 34 I I' 12' I r IN Id 7' 6' 36' 30' 1 I' I r 12 I2' 10' Id 3' 5 I d C • 4 4 7' 40' 1 1' 12' 10' 7' Id 7' 7' 42' 11' 12' Id 9' IC' 7' 7' 4 I r 11 10' 10' 44 46' 1 I' 1 1' 12' 12' Id Id 9 9' 2' 4' C -45 21 LEVEL iS 8' C -41 12 10' Id 14 14' 12' 12' 3' Id 19 14 2' 18' 20 15' 15' C•42 gib Id IN I3' 3' 5 22' 15' 7' C -42 2d 13 7' 15' 9' — • - 22 IN 9' 3' S' C-43 _ 24 IN II' 7' C-43 3d 22 IN ---17- 3 3' C•A4 CV 22 3d 13' IN 10' Id 5' 7' 5' 34 C -43 1d 31' 13' Id 8' 7' IN w' It --� _ 13 10 7' 2' 3' 10' 3' 34 13' Id 7' 4' 5' C -44 3d 1S Id 7' d 7' 38' IN Id 7' 6' 9' 4 d 4 0' 13' I d 7' 7' S 42' 13' Id 7' 7' 5' C -45 4 4 13' IC' 7' 7' 7' 21 LEVEL 8' Id d 10' C•AI 12 12' 12 14 14' 11' 3' Id I6' 1 r 2' 18' 20 15' 15' C•42 18' 11' 7' 22' 15' 7' ad 1 1' 9' 15' 9' — • - 22 24 11' 1 t 8' e' 3' S' C-43 -w 2d 11' d 7' C-43 3d 20' 11' 8' d 3' C•A4 15' 3d 1 r 8' d 5' 34 15' 1d 32 1 1' 8' 6' 7' IN w' It 3 4 1 1' 8' 6' 6' 3' 10' 3' 36' 11' d 6' 6' 5' C-45 38' 11' 8' d d 7' 4d 1 I' d 6' d 9' 21 LEVEL d Id 5 10' C-41 12 12' 14 14' Id 16' 18' 20 15' 15' 3' 5 C•42 22' 15' 7' 24 15' 9' 26' 15' I t 24 15 Id 3' C-43 3d 15' 10' S 32 15' Id 7' 34 15' 1d 9' 3d IN w' It 38' 15' Id 10' 3' C -44 40' IN 10' Id 5' 42' IN Id Id 7' 44 15' Id Id 9' 4 d 15' 10' 10' 11' WALL TYPES NOTE: SEE PAGE 2 FOR DESIGN ASSUMPTIONS SOUTHERN OFFICE 1531 GRAND AVENUE SAN MARCOS, CA 92069 (619) 471-2500 (800) FOR WALL Retaining Walls Company CRIB RETAINING WALL DESIGN TABLES NORTHERN OFFICE 800 E, GRANT LINE ROAD TRACY, CA 95376 (209) 832 -2600 (800) 540 CRIB DRAWING NO. 1 OF 6 REVISED 5/91, 11115 EDIEION SUPERSEDES ALL PREVIOUS EDITIONS PRC•911 r•f" I' IW 1z lid la 1 z l: a DESIGN NOTES: 1) A CRIBWALL ACTS AND MUST BE DESIGNED AS A GRAVITY -TYPE RETAINING WALL. A) SLIDING RESISTANCE IS GENERATED BY INTERNAL SOIL FRICTION (0), COEFFICIENT OF SLIDING ALONG BASE • TAN 0 B) AVERAGE DENSITY OF CRIBWALL IN PLACE IS TAKEN TO BE 125 POUNDS PER CUBIC FOOT (BASED ON 120 AND 150 FOR SOIL AND CONCRETE, RESPECTIVELY). C) A VERTICAL LOAD EQUAL TO 1/3 THE HORIZONTAL LOAD IS APPLIED AT THE REAR OF THE WALL (ALONG ANALYSIS PLANE). 2) EFFECTIVE DEPTH OF WALL IS FROM FRONT OF FRONT STRETCHER TO SURCHARGE BACK OF BACK STRETCHER. 3) TO ATTAIN NECESSARY BASE WIDTH FOR WALL STABILITY, HEADERS CAN BE INTERLOCK - STACKED TO CREATE A MULTI -UNIT BASE. (SEE TYPICAL MULTIPLE -DEPTH WALL CROSS- SECTION, SHEET 4 OF 6 ), 4) DRAINAGE BEHIND WALLS SHALL BE AS SPECIFIED BY SOILS ENGINEER, MANUFACTURER RECOMMENDS AS A MINIMUM THE FOLLOWING: 4" PERFORATED PVC PIPE ENCASED IN 3 CUBIC FEET /FOOT OF 3/4" CRUSHED ROCK WRAPPED IN FILTER FABRIC. w ; n. 5) AS SEEN BY EXAMINATION OF THE DESIGN TABLE, EACH WALL TYPE (C -41, C -42, ETC.) IS BUILT A MINIMUM OF 2 COURSES. FOR EXAMPLE, A 12- COURSE WALL COULD HAVE 12 COURSES OF C -41, OR 10 COURSES OF C -41 AND 2 OF C -42, BUT y2I II COURSES OF C -4I AND 1 OF C -42. 6) THE DESIGN TABLE INCLUDES DMA FOR SURCHARGE LOADING CONDITIONS, ASSUMPTIONS SPECIFIC TO EACH OF THESE ARE AS FOLLOW: A) 2' PLUS TRAFFIC EQUIVALENT FLUID PRESSURE • 30 PCF. 2' PLUS TRAFFIC • 4' LEVEL SURCHARGE. 0 • 30° TAN 0•.58 e) 2: I SLOPE EQUIVALENT FLUID PRESSURE • 43 PCF. (BASED ON RANKINE'S FORMULA, 0 • 30 °) TAN 0 • .58 ,_.C) liZ:l SLOPE EQUIVALENT FLUID PRESSURE • 55 PCF. (BASED ON RANKINE'S FORMULA, 0 ■ 33 °41') Id•34• TAN 0 • .67 D) 2' LEVEL EQUIVALENT FLUID PRESSURE • 30 PCF. 0. 30• TAN 0•.58 ALL DESIGN DATA ARE BASED ON IA:I WALL SLOPE. 7) ASSUMPTIONS NOTED IN 6) ABOVE ARE GENERAL, AS ARE DATA IN THE DESIGN TABLE, IN MOST CASES, IT IS APPROPRIATE TO RELY ON A SOIL INVESTIGATION FOR SPECIFIC ALLOWABLE FOUNDATION PRESSURES AND LATERAL LOADING, AS WELL AS OTHER SOIL PARAMETERS REQUIRED FOR DESIGN. 8) OVERALL STABILITY OF SLOPE WITH WALL IN PLACE MUST BE ANALYZED. (RETAINING WALLS, CO., DOES NOT OFFER THIS SERVICE. THIS IS TYPICALLY A RESPONSIBILITY OF THE SOILS ENGINEER). 9) IF GROUND SLOPES AWAY FROM TOE OF WALL, A REDUCTION IN ALLOWABLE FOUNDATION PRESSURE OR A MINIMUM HORIZONTAL SETBACK FROM FACE OF BANK MUST BE CONSIDERED. 10) DESIGN TABLE PROVIDES DESIGN DATA FOR WALLS UP TO 46 FEET HIGH. IF HIGHER WALLS ARE NEEDED, CUSTOM DESIGN 1S REQUIRED. I1) ALL WALLS AND DESIGNS ON THESE STANDARD PLANS ARE SHOWN AT •I /•I WALL SLOPE (BATTER), IF STEEPER SLOPES ARE NEEDED, CUSTOM DESIGN IS REQUIRED. SOUP IERN OFFICE 1531 GRAND AVENUE SAN MARCOS, CA 92069 (619) 471.250(3 (000) FOR WALL Retaining Walls Company CRIB RETAINING WALL DESIGN NOTES NORTHERN OFFICE 800 E. GRANT LINE ROAD TRACY, CA 95376 (209) 832 -2600 (800) 540 CRIB DRAWING NO. 2 OF 6 REVISED 5/91, TIIIS EDITION SUPERSEDES ALL PREVIOUS EDITIONS PRC•911 FRONT STRETCHER BACK STRETCHER FALSE HEAOE11 r81 JC STRETCHERS END VIEWS A 1'y• MIN. (TYP.) A HEADERS 1'!" MIN. RYP —) L TOP VIEWS �H. C END VIEWS SIDE VIEWS J. ID 1'4' MIN. (TYP.) NOTES: 1. STRENGTH OF MATERIALS A. COMPRESSIVE STRENGTH OF CONCRETE (lc " 3250 P81 B. YIELD STRENGTF OF STEEL f y - 00.000 PSI 2, MANUFACTURE A. GRIDLOCK UNITS ARE MANUFACTURED BY BOTH THE "DRYPACK" METHOD AND THE 'WETPOUR" METHOD. DEPENDING ON PLANT LOCATION. 8. MANUFACTURING SITES 1. RETAINING WALLS COMPANY 1025 GRAND AVE. SAN MARCOS, CA 2. RETAINING WALLS COMPANY 800 GRANT LINE ROAD TRACY, CA a ACTUAL MEMBER SIZES MAY CHANGE. CONTACT R.W.C. FOR CURRENT MEMBER DIMENSIONS. DIMENSIONS FALSE HEADER 5 FT. HEADER 3 FT. HEADER 4 FT. HEADER FRONT STRETCHER BACK STRETCHER (REDUCED FALSE HEADER OPENING) 41>i FT. HEADER (REDUCED OPENING) A B C ._. _ -__.._._.. _ D E F 0 H I K RE -BAR SIZES 10" 5' - 0" 3' — 0" 4' — 6" 5' — 0" 3' — 9" 10" 4'— 6" 7" 10" .... 1 %1i .... I" 8" — 4" — — — +" 9.5" 1.5" .75" B" 6" 4" 1.75" 1" 7„ II 7 1�i 4" 4" 7., 7" 11" 2%t K— .. I �e" 8" 6" 4" 24 " 1 it' 9.5" .__._ .. 1.5" .75" 6" 6" 8.6" 8.6" 1" 1" 1.25" 2.5" �." ado' 1.5" 1.5" 8" — — 5,6" 5.6" 6" 4" — — — 5.6" — — 4" 4" 1.75" — — — 1,5" I " - - - 1.5" *4 *4 #4 #4 *4 — # 4 UNIT WEIGHTS 30 LBS. 145 LBS. 95 LBS, 135 LBS. 125 LBS. 95 LBS. 25 LBS. 125 LBS. SOUII IERN OFFICE 1531 GRAND AVENUE SAN MARCOS, CA 92069 (619) 471 -2500 (800) FOR WAI.I. Retaining Wails Company CRIB RETAINING WALL MATERIAL NORTHERN OFFICE 800 E. GRANT LINE ROAD TRACY, CA 95376 (209) 832 -2600 (800) 540 CRIB DRAWING NO. 3 OF 6 REVISEI) 5/91, 11115 EDITION SUPERSEDES M.I. PREVIOUS EDITIONS PRC•911 FRONT STRETCHERS MP) PLANTING AREAS (TYPIA ?1P.1SAL It 2'6 2-6• BACK A OR IT YP) FALSE— HEADER IT fin,. ALTERNATING\ JOINTS (TYPI BACK STRETCHER HEADER (TYP) ELEVATION ITYPICAL) 0 .I n —FRONT STRETCHER ITYP) PLAN VIEW BASE COURSE (TYPICAL MULTIPLE DEPTH WALL) ryMGNVOICI.+ �'ANalt '. �1fIT_E IvAAnat '?S 1 RETAINED HEIGHT H I4 IF to •ROUN0 / LWEL • ice'' VM1[s 3+ DIN 1' 1313 101115 3'') 011_ CROSS SECTION (TYPICAL SINGLE DEPTH WALL) MO,NONIAI NOTE Mt A1431 YAOP(p •AN •A' AOL 31311 ,1t AOr11 ALL 013I11 ART 3AL1t ML A01o1 CONSTRUCTION NOTES: I) USE OF FALSE HEADERS A) FALSE HEADERS ARE NOT ALLOWED AT ENDS OF WALLS OR IN TOP COURSE Of WALLS. 6) FALSE HEADERS ARE NOT USED IN INTERIOR OF MULTIPLE -DEPTH WALLS. 2) UNSUPPORTED HEIGHT AT ENDS OF WALLS NOT TO EXCEED 4 PEET. 3) SPECIAL NOTE SHALL BE TAKEN OF ALTERNATING - JOIN1 CONSTRUCTION, AS SHOWN IN TYPICAL CROSS - SECTIONS, BASE COURSE PLAN VIEW, AND ELEVATION. *100? a1•CTCMLNIITPI. M1A010 11133) — RETAINED HEIQNT • N 1t•KoPu1! I1TP� GODU*0 1 l vlb. L ML/ 1'WN r!1TIOL ' vru' toot 1vMMt11 or _— .' -:.i awlit llYSl. E01. 1 �-- 0ACN ST3L3CML31,,11 005103 EFFEC)iVE'OEp''N .. 74103E 6HJ tot„ NI NQIIIIUIIT� tl CROSS SECTION (TYPICAL MULTIPLE DEPTH WALL) SOUTHERN OFFICE 1531 GRAND AVENUE SAN MARCOS, CA 92069 (619) 471.2500 (800) FOR WALL Retaining Walls Company CRIB RETAINING WALL ERECTION NORTI IERN OFFICE 000 E. GRANT LINE ROAD TRACY, CA 95376 (209) 032'2600 (800) 540 CRIB DRAWING NO. 4 OF 6 REVISED 5/91, TIIIS EDITION SUI'ERSEDES ALT. PREVIOUS EDITIONS PRC•91( M NS OTES : WS/04U CCO1 O10ot000 11MST0NTIAL IINOLT O TAU ER 00itlIA GR AM twl�� MWONID • MT0IL /O AT PROM/ INMNIIR. C0 MUM Rt0O CA LATER Tt TO M W, 04111.01001 MAMMAL. DRAINAGE BEHIND WALLS SHALL BE AS SPECIFIED BY SOILS ENGINEER, MANUFACTURER RECOMMENDS AS A MINIMUM THE FOLLOWING: 4" PERFORATED PVC PIPE ENCASED IN 3 CUBIC FEET /FOOT OF 3/4" CRUSHED ROCK WRAPPED IN FILTER FABRIC. DETAIL 1- DRAINAGE BEHIND WALL DETAIL 3- CURB a GUTTER NOTES: 1) ate MTI"il4(08 it 11 0*01I *to a', DITCH MUG MIT N MORT TW1 1' *08811 A LONG PRIKN 01 120(1. MAIL 84000(8 MORE To RAINIEST R 11111■011 0 0 *00011117, I) 80IC9K8 O0 DIVINE10N1 • DESIGN 00 V -DITCH MAT N VARIED 10 MOLT 11000114. $$$$$ OP 4IM111NCl0l1 M(NCT. 11 I0 11/47(1 18 CAR11M0 0000 010)1 DOWN A p1A1NAM 01700 AT 01I/I1 TO 101 COLLECTOR DITCH ON TOP OF WALL. A SPLASH GOARO ANRAI0IMINT 11 N10N010 TO *0010 OATEN (801141 MITT 010E 01 WALL. 110 S t RETAILED OM 0ROJK1 PLANS1 4) GRAIN ►401 01 0100 • !MEWS AS 0000,00 OT 0101100701E 108801. 111014011 0' DOMNIT0RI TRACT LOCATIONS 01 00CNAR01 POINTS 10 NE 10000 ON PROJECT PLANS. 0011 1101 DRAINAGE • 001111- PIPES ARE NOT O 10010(0 WIMRI COLLECTION DITCH DSCH00011 AT ON CON10111(8 MST ENO OF WALL. D I I0AN0181NT RANAGE 4 0108 70 '0' DETAIL 2 - BROW DITCH SOUTHERN OFFICE 1531 GRAND AVENUE SAN MARCOS, CA 92069 (8191 471 -2500 (800) FOR WALL. Retaining Walls Company CRIB RETAINING WALL DETAIL NORTHERN OFFICE 800 E. GRANT LINE ROAD. TRACY, CA 95376 (209) 832 -2600 (800) 540 CRIB REVISED 5/91, TIIIS EDITION SUPERSEDES Ml. PREVIOUS EDITIONS DRAWING NO. 5 OF 6 PRC -911 vA.af ruq� _. { vM1(f, DETAIL 4 - SIDEWALK NOTCD 11 1,001 0 114* HIA00 MAIL 010 00110/01 10100010 1,140 117 -C1 OR A1, -C*, 00 10/00810 10011. 71 C ^11, O'CCt N1111 1 0• 0 0000011. • NOTE 11110001 o1 9070140 war RANT TO Nllt 00■01010010T. *010000 11100101* 1, 1f -'I DETAIL .6 - GUARD RAIL 17 1,01 0111 , 0 NOTES: " t LI00 111 A) /000*C0 1 pN 0100* 1 1`110 *001. 71 00 i' 10 1111111 C1111111 0 0000111 DETAIL 5 -CHAIN LINK FENCE NOTE; AS -BUILT WALL SAFETY, SUCH AS INSTALLATION OF FENCING OR GUARDRAILS IN AREAS ACCESSIBLE TO PEDESTRIAN OR VEHICLE TRAFFIC, IS THE RESPONSIBILITY OF THE OWNER. SOUTHERN OFFICE 1531 GRAND AVENUE SAN MARCOS, CA 92069 (619) 471-2500 (800) FOR WALL Retaining Walls Company CRIB RETAINING WALL DETAIL NORTHERN OFFICE 800 E. GRANT LINE ROAD TRACY, CA 95376 (209) 832.2600 (800) 540 CRIB DRAWING NO. 6 OF 6 REVISED 5/91, THIS ED11I0N SUPERSEDES ALL PREVIOUS EDITIONS PRC•911 ' 1 1, 116111MW 43 7 7. c 8G ,z c A p asatcawaasswarboossammtiummoranuArmiareausEtulaumsloominniesammalingaga swalowwwwwisawswilwaggisawaxnakwailamolaammesnommear 0- --Powtg roLe ;, , ReNTON 11.1R ZE TReC Pr. R12. EXT.& R.M01.S " •-•.` •T ••••••••1•0 N \.• \MUD •■••■•••■•••••04•••■■•S•gt•••••■1'1■6•111MIONS601•• 11 'WOO" W ,. •blilomMilmilli ens gam .............•.....• (7/ cs • • - F = R.cc.KeiZs( Lzr4:70x..4.%rir,& & 12." FR F F F-' K I N RA E)(1 .5.41.11JGr gg.3 &Art OK) 6 rqcNr STRETCHER (TYP) (5• :RONr STRiFTCHER OPTIONAL) r — F7NiSHED GRADE BEHIND WALT --- 2111111111111111n11111r111111111.111111111101.11V .1111111f:, II 11ri ie1011111111•11711,011111111111111: MINIIVEVINIIII1111111110:1111121: 111111111111,1111C1111111 (r-•) R.CCkele-Y FALSE HEADER (TYR) TYDICAL WALL PROFILE risit7 r1 11441..- \--FLU HEADER (7111) FiNISHEO GRADE A r FRONT FACE N,)7 TO Satt.::: r IMPOINII•1■11=101■4.110:1•■•••••••■.•77•••••womelamosmaamoramomemnlomar•rormempwaromeraoul••••••a•••=am......rissmovas••••-■•••••••••••. WarnagNiMaNn••• tyMI OWW • •:•••MMO44•As.awai.i••••■•Ai1o0.•••Weser■Ii.v,.. •••••• ••••.,ffeonr9N.V./16"-* - • • • (70° ••■my" -Fuze 1-I'NT 1 PLANTIN(7 0:71. R.. I P 4". Rae- le-EY---, CITY P R 0 •--_ •11. 21510•3•Yea..... . • no....110••••••.104 •••••••PICIO.4..wcaosh••••••se , MARXN;J:, 14" A C — .......,,,,,A•arYs•saMMOnninsftWaram0.6.4•••malirastm* •••• *W., -14..• • ce,•••■• gymomm N eitYlf2,100" w .9 0 00 • 7 Lw3sclwe §311-121, aatALT: D 500 IVY atetRA.. Hew) ,OOO:4 5.(ati° Loo 6rot,i) 1-kiciroect 8 1C:A L (3 0,C. Top oPi....xx,k1 L._ N 0R 199Z 1" 10' UDoULuJ 0)412. peEpAtarj), 8.11 Reic,fni . NOSCAPING PLAN oJb nA.,.74%o V\A 49-e4cy:21111 OF 100 11$t Ave. SE Bellevue, WA 98004 Suite 4102 (206)455-6484 OATS 69110016661616011111161061661666.A..1..." , . . • • - • • • 111111 11 1 I 1 1 I 1 1 1 I 111111111111111 I 1 1 1 I 1111111 I 1 1 1 1,1.11 1 1 rl 0 16 THS INCH 1 2 3 lit 1jJ itintirri i M1111111111111111111 III !I 4 5 6 7 NOtE: if the microfilmed document is leus clear than this : i • ' notice it is due to the quality of the "original document 11111111 10 11 4DE "MI" 12 06 6Z 86 L 9Z GZ r CF ZZ I,F 0? at 0111111111111111111111111116411.111D1111111111111.41111111111111111111111111IIIIIIIIIPUL • . .. , - , . ' „, .. , •