Loading...
HomeMy WebLinkAboutPermit D06-423 - L & R Services - Storage and Mixing RoomL & R SERVICES INC 4712 S 134 PL D06 -423 Parcel No.: 2616600071 Address: 4712 S 134 PL TUKW Suite No: Tenant: Name: L&R SERVICES INC Address: 4712 S 134 PL , TUKWILA WA City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: httn: / /www.ci.tukwila.wa.us Owner: Name: SCKWEIGER ERIC M Address: 4712 SOUTH 134TH PL , SEATTLE WA 98168 Phone: Contact Person: Name: RUBEN PENA Address: 4712 S 134 PL , SEATTLE WA 98168 Phone: 206 391 -8282 Contractor: Name: OWNER AFFIDAVIT- ERIC M SCRWEIGER Address: , Phone: Contractor License No: DEVELOPMENT PERMIT * *continued on next page** Permit Number: D06 -423 Issue Date: 01/29/2007 Permit Expires On: 07/28/2007 Expiration Date: DESCRIPTION OF WORK: CREATE NEW PAINT STORAGE AND MDCING ROOM WITH FIRE EXTINGUISHING SYSTEM. Steven M. Mullet, Mayor Steve Lancaster, Director Value of Construction: $1,868.00 Fees Collected: $139.67 Type of Fire Protection: AFA International Building Code Edition: 2003 Type of Construction: VB Occupancy per IBC: 0025 doc: IBC -10/06 1306 -423 Printed: 01-29-2007 Public Works Activities: Channelization / Striping: N Curb Cut / Access / Sidewalk / CSS: N Fire loop Hydrant: N Number: 0 Size (Inches): 0 Flood Control Zone: Hauling: N Start Time: End Time: Land Altering: Volumes: Cut 0 c.y. Fill 0 c.y. Landscape Irrigation: Moving Oversize Load: Start Time: End Time: Sanitary Side Sewer: Sewer Main Extension: Private: Public: Storm Drainage: Street Use: Profit: N Non - Profit: N Water Main Extension: Private: Public: Water Meter: N Permit Center Authorized Signature I hereby certify that I have read and e governing this work will be complie The granting of construction or Print Name: doc: IBC-10 /06 Signature: rmit does not p erformance of w City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: httn: //www.ct.tukwila.wa.us Permit Number: DO6 -423 Issue Date: 01/29/2007 Permit Expires On: 07/28/2007 Date: a 121 Steven M. Mullet, Mayor Steve Lancaster, Director permit and know the same to be true and correct. All provisions of law and ordinances her specified herein or not. ume to give authority to violate or cancel the provisions of any other state or local laws regulating I am authorized to sign and obtain this development permit. nt Date: / d 9-to 7 This permit shall become null and void if the work is not conunenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. 006 -423 Printed: 01 -29 -2007 Parcel No.: 2616600071 Address: 4712 5 134 PL TUB:W Suite No: Tenant: L&R SERVICES INC 1: ** *BUILDING DEPARTMENT CONDmONS * ** City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http : / /www.cttukwila.wa.us PERMIT CONDITIONS Permit Number: D06 - 423 Status: ISSUED Applied Date: 11/13/2006 Issue Date: 01/29/2007 2: No changes shall be made to the approved plans unless approved by the design professional in responsible charge and the Building Official. 3: All permits, inspection records, and approved plans shall be at the job site and available to the inspectors prior to start of any construction. These documents shall be maintained and made available until final inspection approval is granted. 4: All construction shall be done in conformance with the approved plans and the requirements of the International Building Code or International Residential Code, International Mechanical Code, Washington State Energy Code. 5: There shall be no occupancy of a building until final inspection has been completed and approved by Tukwila building inspector. No exception. 6: Remove all demolition rubble and loose miscellaneous material from lot or parcel of ground, properly cap the sanitary sewer connections, and properly fill or otherwise protect all basements, cellars, septic tanks, wells, and other excavations. Final inspection approval will be determined by the building inspector based on satisfactory completion of this requirement. 7: Manufacturers installation instructions shall be available on the job site at the time of inspection. 8: All electrical work shall be inspected and approved under a separate permit issued by the Washington State Department of Labor and Industries (206/248- 6630). 8: VALIDITY OF PERMIT The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. 10: ** *FIRE DEPARTMENT CONDITIONS * ** 11: Extinguishers shall be located in conspicuous locations where they will be readily accessible and immediately available for use. These locations shall be along normal paths of travel, unless the fire code official determines that the hazard posed indicates the need for placement away from normal paths of travel. (IFC 906.6) 12: Fire extinguishers shall not be obstructed or obscured from view. In rooms or areas in which visual obstruction cannot be completely avoided, means shall be provided to indicate the locations of the extinguishers. (IFC 906.6) 13: Portable fire extinguishers, not housed in cabinets, shall be installed on the hangers or brackets supplied. Hangers or brackets shall be securely anchored to the mounting surface in accordance with the manufacturer's installation instructions. Portable fire extinguishers having a gross weight not exceeding 40 pounds (18 kg) shall be installed so that its top is not more than 5 feet (1524 nun) above the floor. Hand -held portable fire extinguishers having a gross weight exceeding 40 pounds (18 kg) shall be installed so that its top is not more than 3.5 feet (1067 nun) above the floor. The clearance between the floor and the bottom of the installed hand -held extinguishers shall not be less than 4 doc: Cond -10/06 D06.423 Printed: 01 -29 -2007 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: httn : / /www.ci.tukwila.wa.us inches (102 mm). (WC 906.7 and IFC 906.9) 14: Fire extinguishers require monthly and yearly inspections. They must have a tag or label securely attached that indicates the month and year that the inspection was performed and shall identify the company or person performing the service. Every six years stored pressure extinguishers shall be emptied and subjected to the applicable recharge procedures. If the required monthly and yearly inspections of the fire extinguisher(s) are not accomplished or the inspection tag is not completed, a reputable fire extinguisher service company will be required to conduct these required surveys. (NFPA 10, 4 -3, 4-4) 18: An approved automatic fire-extinguishing system is required for this project. 16: There can be no storage under stairs unless the following conditions are met. The walls and soffits within enclosed usable space under enclosed and unenclosed stairways shall be protected by 1 -hour fire - resistance -rated construction, or the fire- resistive rating of the stairway enclosure, whichever is greater. Access to the enclosed usable space shall not be directly from within the stair enclosure. There shall be no enclosed usable space under exterior exit stairways unless the space is completely enclosed in 1 -hour fire-resistance-rated construction. The open space under exterior stairways shall not be used for any purpose. (IFC 1019.1.8) 17: Each door in a means of egress from an occupancy of Group A or E having an occupant load of 100 or more and any occupancy of a Group 11 -1, 11-2, 11-3 or 11-8 shall not be provided with latch or lock unless it is panic hardware or fire exit panic hardware on rated fire doors. (IFC 1008.1.9) 18: Fire doors shall be maintained in operative condition at all times, including complete closure and latching of the assembly. (IFC 1019.1.1) 19: Manually operated flush bolts or surface bolts are not permitted. (IFC 1008.1.8.4) 20: U.L. central station supervision is required. (City Ordinance #2050) 21: Fire detection, alarm and extinguishing systems shall be maintained in an operative condition at all times, and shall be replaced or repaired where defective. Non - required fire protection systems and equipment shall be inspected, tested and maintained or removed. (IFC 901.6) 22: The installation of wiring and equipment shall be in accordance with N.F.P.A. T0, Article 760, Fire Protective Signaling Systems. (NFPA 72 -L13) 23: All new fire alarm systems or modifications to existing systems shall have the written approval of The Tukwila Fire Prevention Bureau. No work shall commence until a fire department permit has been obtained. (City Ordinance #2051) (IFC 104.2) 24: Emergency alarm signaling devices required as a result of hazardous materials storage, use and/or handling shall be tied into a fire alarm panel and monitored by a City approved U.L. central system. (City Ordinance #2051) 25: Key box - When access to or within a structure or an area is unduly difficult because of secured openings or where immediate access is necessary for life- saving or fire- fighting purposes, the Chief may require a key box to be installed in an accessible location. The key box shall be a type approved by the Chief and shall contain keys to gain necessary access as required by the Chief. (IFC 506.1) 26: The Tukwila Fire Department has changed keybox manufacturers from Supra to Knox. Install a fire department Knox Box. Contact the Tukwila Fire Department Prevention Office at 206 - 578.4407 for ordering information. 27: Fire Department lock boxes shall be provided for access to all fire alarm panels and sprinkler risers. The appropriate key(s) for access shall be placed in the lockbox. Lockbox order forms must be obtained from the Tukwila Fire Department. The lockbox should be mounted so that it is readily visible and not over 60 inches high. (City Ordinance #2051) doc: Conti DO6.423 Printed: 01-29-2007 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206431 -3670 Fax: 206431 -3665 Web site: http: / /www.ci.tukwila.wa.us 28: An electrical permit from the Washington State Department of Labor and Industries is required for this project. 29: All electrical work and equipment shall conform strictly to the standards of the National Electrical Code. (NFPA 70) 30: Spill containment systems or means to render a spill harmless to people or property shall be provided where a spill is determined to be a plausible event and where such an event would endanger people or property. (IFC 2701.3.3.4) 31: Required fire resistive construction, including occupancy separations, area separation walls, exterior walls due to location on property, fire resistive requirements based on type of construction, draft stop partitions and roof coverings shall be maintained as specified in the Building Code and Fire Code and shall be properly repaired, restored or replaced when damaged, altered, breached, penetrated, removed or improperly installed. (IFC 703.1) 32: When walls and ceilings are required to be of fire resistive or noncombustible construction, interior finish materials shall meet the requirements of International Building Code 803. 33: The maximum flame spread class of finish materials used on interior walls and ceilings shall not exceed that set forth in Table No. 803.8 of the International Building Code. 34: When fire resistive floor or floor ceiling assemblies are required to prevent the vertical and horizontal spread of fire and smoke, the assembly shall be maintained. (IBC 712.4.2) 35: There shall be no enclosed usable space under stairways in an exit enclosure, nor shall the open space under such stairways be used for any purpose. (IBC 315.2.4) 36: Maintain coverage and operability of portable fire extinguishers, sprinkler systems and fire alarm systems during demolition and construction. 37: Contact The Tukwila Fire Prevention Bureau to witness all required inspections and tests. (City Ordinances #2050 and #2051) 38: Any overlooked hazardous condition and/or violation of the adopted Fire or Building Codes does not imply approval of such condition or violation. 39: These plans were reviewed by Inspector 512. If you have any questions, please call Tukwila Fire Prevention Bureau at (208)878 - 4407. doe: Cond -10/06 * *continued on next page ** 006-423 Printed: 01 -29 -2007 Signature: Print Name: City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 - 431 - 3665 Web site: http: / /www.ci.tukwila.wa.us I hereby certify that I have read these conditions and will comply with them as outlined. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provision of any other work or local laws regulating construction or the performance of work. r\ 11h17 Ate Date: / a '-o 7 doc: Cond -10/06 D06-423 Pdnted: 01 -29 -2007 E -Mail Address ( (r� �ITGtl 0.� aD�• ('ptt� Company Name: Mailing Address: Company Name: Mailing Address: CITY OF TUKWILA Community Developmen' impartment Public Works Department'✓ Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www.ct tukwila. wa. us Contact Person: E -Mail Address: Contractor Registration Number: Contact Person: E-Mail Address: Q: Applicatiomtrotme- Applications On Line- 2096 - Permit Application doc Reviead 9-2006 bh Building Permit No. Mechanical Pbrtiit No Plumbing/Gas Permit No Public Works Permit No Project No. (For offlCe e only) Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. "Please Print** 1 King Co Assessor's Tax No.: (P.0- 033 5(0 ac, Site Address: '1 r1 l 1 1 .I— I )Y S s (J4 Suite Number: 4t 8 Floor: ,pp Tenant Name: I� .� C vA 1 )I tOy• LA. � AYlto$ , New Tenant: 0 .... Yes IThNo Property Owners Name: E r i C. S C .-. 1,0 P i ry Mailing Address: y a Sa L. 34 S P t• l �a 9BI(�S City State Zip CONTACT PERSON - who do we contact when your permit is ready to be issued Name: 1Aiil P n "FP.h (.t Day Telephone: ao - j91- 5.2.52 Mailing Address: 41 I . '—o t.1 i I &- "- S e Lo i J GZ • `7' R /IA City State Zip Fax Number: lvlo - ' - 1 L 4 - Li _I I 1 GENERAL CONTRACTOR INFORMATION - (Contractor Information for Mechanical (pg 4) for Plumbing "and Gas Piping (pg 5)); City State City Day Telephone: Fax Number: Expiration Date: ARCHITECT. OF RECORD - All plans must be wet stamped by Architect ofRecord State Zip Zip City Day Telephone: Fax Number: ENGINEER OF RECORD - All plans must be wet stamped by Engineer of Record Company Name: Mailing Address: 2 6 Zl 4s& kt/6-S KeM w 11 03 a. State Zip Contact Person:Ghl-ka[,65 7- De Thowz!G Day Telephone: X753- RS 4 -t.Z 4' E -Mail Address: G.v( monfttwo Z a. MSA/ • Co rs Fax Number: a K 3 - SS 4 -ZZA -I Page 1 of 6 BUILDING PERMIT WORMATIUN ZOf -43' Valuation of Project (contractor's bid price : $ , / c34, g Existing Building Valuation: $ Scope of Work (please provide detailed information): C ,Q to iC ,v iw 1/1- t u 41 u (L/a -Gi G ', rn /A r "- 4 1 - g Objl\ bu I7"li frt1E- (tir issi A./ 51 ' - Will there be new rack storage? 0.... Yes (�tNo If yes, a separate permit and plan submittal will be required. ()vide Alt Ildmg Areas in Square rootage Below` at. 1 F,1 `Attached ched G �!A ch etaeheil G 3 5 V 5 PLANNING DIVISION: Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) _ *For an Accessory dwelling, provide the following: Lot Area (sq ft): Floor area of principal dwelling: Floor area of accessory dwelling: *Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard: Compact: Handicap: Will there be a change in use? ❑ Yes ❑ No If "yes ", explain: FIRE PROTECTION/HAZARDOUS MATERIALS: ❑ Sprinklers ❑' Automatic Fire Alarm ❑ None ❑ Other (specify) Will there be storage or use of flammable, combustible or hazardous materials in the building'? ❑ Yes ❑ No If 'yes', attach list of materials and storage locations on a separate 8-1/2" 11 "paper including quantities and Material Safety Data Sheets. SEPTIC SYSTEM ❑ On-site Septic System —.For on -site septic system, provide 2 copiesAf a current septic design approved by King County Health Department. Q:Upplications\Fonns- Applications On Line\3 -2006 - Permit Application.doc Revised: 9 -2006 bh Page 2 of 6 . PERMIT _APPLICATION NOTES"IApplicable to all permits in this Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply witb current fee schedules. Expiration of Plan Review — Applications for which no permit b issued within 180 days following the date of application shall expire by limitation. Building and Mechanical Permit The Building Official may grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be requested in writing and justifiable cause demonstrated Section 103.32 International Building Code (current edition). Plumbing Permit The Building Official may grant one extension of time for an additional period not exceeding 180 days. The extension shall be requested In writing and justifiable cause demonstrated. Section 103.4.3 Uniform Plumbing Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OW R OR AUTH� GENT: Signature: l • �� Print Name: eg IC /W Sc_ LA/ t I y e2 Mailing Address: I Date Application Accepted IlivActi9 Q:wNio.u'smMPPamlon o.Line13-20 6 Permit Application.doe twist 94.006 bh Day Telephone: ?0 e D i 3 t City a tion e`er r Date: Wee Lp Date Application Expires: ic(lg7 Staff Initials: n — 1 Page 6 of 6 1 Parcel No.: 2616600071 Address: 4712 S 134 PL TURW Suite No: Applicant: L&R SERVICES INC Receipt No.: R06 -01809 Payee: L & R SERVICES, INC. ACCOUNT ITEM LIST: Description doc: Receipt -06 BUILDING - NONRES PLAN CHECK - NONRES STATE BUILDING SURCHARGE City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206-431-3665 Web site: http: //www.ci.tukwila.wa.us RECEIPT Initials: JEM Payment Date: 11/13/2006 11:48 AM User ID: 1165 Balance: 30.00 TRANSACTION LIST: Type Method Description Amount Payment Check 2849 139.67 Account Code Current Pmts 000/322.100 000/345.830 000/386.904 Permit Number: D06 -423 Status: PENDING Applied Date: 11/13/2006 Issue Date: Payment Amount: $139.67 81.92 53.25 4.50 Total: $139.67 1681 11/13 9716 TO1AL. fl?ted7711 -13 -2006 COMMENTS: 0 ) i — ApprOVeto C 2-) ( i A 11100.4-ve - Ap e tin 10 Date Called: Special Instructions: r- 5 ) ' - 1 ) Pr vvCrt - (' t ? te-fe/COAjA f Requester: Phone No a0G-3cl-C?s N Project: LiPQ. SorVitr og- Type cAinvection; F p■JA I Address: ? S ( 3 Li f 1/4..... Date Called: Special Instructions: Date Want ed: 1. ... l 0 ..."° PI cfLet: Requester: Phone No a0G-3cl-C?s tus,crioN NO. INSPECTION RECORD Retain a copy with permit CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 at&-qz3 PERMIT NO. re. (206)431-3670 RI Approved per applicable codes. Corrections required prior to approval. n ector: $ paida 'Receipt No.: INSPECTION FEE I1EOJJIRED. Pcior o inspection, fee must be 00 Southcenter Blvd., Suite 100. Cal the schedule reinspection. I i Date: Project/ n e ,' - - ' -4V4J-rcl Type of Inspection: i V - . t / Addrees: 4 /7/2_ • cl / 3 I V - ) Date Ca ---..._ nt . _ Special I7structions: Date Wanted: n c , • ea Requester: n Phone No: . '- l .7-41-197 C7S7 Approved per applicable cotles,/ gi Corrections required prior to approval. i COMMENTS: /) #4 eie • te 7 --.1-4-e-., 1 2 )-4,e4i , c .„ /i i 7 f 6 Cf.f.ei, /2-7,- «6i (-24. rs )) /1-dd 44die .4 /1-47. 4,17, -66 i 7 7 /o 5 /7 Sc 39 in i>g I e v hater '4 ./.---t-eA.mi 7 .n" Ai i . At do _.,... . INSPECTION RECORD Retain a copy with pegnit is _ INSP CTION NO. PERMIT Not crof_ OF,TUKWILA BUIpING DIVISION Ve 6o6 Sotthcenter B vd., #100, Tukw la, WA 98188 (206)431 r eceiPt No.: Inspector: • 'Date: IDate: 7/167 $58.00 REINSPECTION FEE REQUIRED. Prior o inspection. fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call the schedule reinspection. ' Proj ct: - FC -9/0 P /AC Type of In ectlon: V /= A/4 / Address: 5 /J t-/ D Date Called: Special Instructions: Date Wanted: / 07 Requester: Phone No X06 - 3 9 / - 573 7 Approved per applicable codes. corrections required prior to approval. COMMENTS: / /- — A/r-1 c� Aieir , • (,✓ni /S r /�c2;/:(1/ - /J -iv/ +svii, - G ./i1 / /�09✓f/ i ts oon 'rt— 7C N ns dT tor: / -1 Receipt No.: INSPECTION RECORD Retain a copy with permit INSPECTION NO. CITY OF TUKWII.A BUILDING DIVISION 6300 Southcenter Blvd.; #100, Tukwila, WA 98188 558.00 REINSPEC IO E REQOIRED. Prior o inspection, fee must be paid at 6300 Southcen r Blvdd Suite 100. Call the schedule reinspection. (Date: IDT1 r1 Project L I' ? S t ✓iet S Type of Inspection: FA 1-i4AL Address: 4/9/2 5. Suite #i / 3 Contact Person: 4 Special Instructions: Permits: Phone No.: Needs Shift Inspection: Sprinklers: e Fire Alarm: Hood & Duct: Monitor: Pre -Fire: Permits: Occupancy Type: CITY OF TUKWILA FIRE DEPARTMENT 444 Andover Park East, Tukwila, Wa. 98188 206 - 575 -4407 - Approved per applicable codes. COMMENTS: 0 cuvvi21; ,1* 9460. Ok (9 P a 014 h )y Inspector: Date:gll6 /07 Hrs.: /, INSPECTION NUMBER INSPECTION RECORD Retain a copy with permit Word /Inspection Record Form.Doc 1/13/06 PERMIT NUMBERS n Corrections required prior to approval. $80.00 REINSPECTION FEE REQUIRED. You will receive an invoice from ity of Tukwila Finance Department. Call to schedule a reinspection. T.F.D. Form F.P. 113 01 -08 -2008 RUBEN PENA 4712 S 134 PL SEATTLE WA 98168 RE: Permit No. 006-423 4712 S 134 PL TUKW Dear Permit Holder: In reviewing our current records the above noted permit has not received a final inspection by the City of Tukwila Building Division. Per the International Building Code and/or the International Mechanical Code, every permit issued by the Building Division under the provisions of this code shall expire by limitation and become null and void if the building or work authorized by such permit is not commenced within 180 days from the date of such permit, or if the building or work authorized by such permit is suspended or abandoned at any time after the work is commenced for a period of 180 days. Based on the above, you are hereby advised to: Call the City of Tukwila Inspection Request Line at 206431 -2451 to schedule for the next or final inspection. This inspection is intended to determine if substantial work has been accomplished since issuance of the permit or last inspection; or if the project should be considered abandoned. If such determination is made, the Building Code does allow the Building Official to approve one or more extensions of time for additional periods not exceeding 90 days each. Extension requests must be in wriina and provide satisfactory reasons why circumstances beyond the applicants control have prevented action from being taken. In the event you do not call for the above inspection and receive an extension prior to 02/23/2008 , your permit will become null and void and any further work on the project will require a new permit and associated fees. Thank you for your cooperation in this matter. Sincerely, er Marshall, Permit Technician xc: Permit File No. 006-423 City of Tukwila Jim Haggerton, Mayor Department of Community Development Jack Pace, Director 6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone: 206- 431 -3670 • Fax: 206- 431 -3665 06-04-2007 RUBEN PENA 4712 S 134 PL SEATTLE WA 98168 RE: Permit No. 1306-423 4712 S 134 PL TUKW Dear Permit Holder: In reviewing our current records the above noted permit has not received a final inspection by the City of Tukwila Building Division. Per the International Building Code and/or the International Mechanical Code, every permit issued by the Building Division under the provisions of this code shall expire by limitation and become null and void if the building or work authorized by such permit is not commenced within 180 days from the date of such permit, or if the building or work authorized by such permit is suspended or abandoned at any time after the work is commenced for a period of 180 days. Based on the above, you are hereby advised to: Call the City of Tukwila Inspection Request Line at 206-431 -2451 to schedule for the next or final inspection. This inspection is intended to determine if substantial work has been accomplished since issuance of the permit or last inspection; or if the project should be considered abandoned. If such determination is made, the Building Code does allow the Building Official to approve one or more ex tensions of time for additional periods not exceeding 90 days each. Extension requests must be to writing and provide satisfactory reasons why circumstances beyond the applicants control have prevented action from being taken. In the event you do not call for the above inspection and receive an extension prior to 07/28/2007 , your permit will become null and void and any further work on the project will require a new permit and associated fees. Thank you for your cooperation in this matter. Sincerely, fer Marshall, Permit Technician xe: Permit File No. D06-423 City of Tukwila Steven M. Mullet, Mayor Department of Community Development Steve Lancaster, Director 6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone: 206 -431 -3670 • Fax: 206 - 431 -3665 ACTIVITY NUMBER: D06 -423 DATE: 11 -13 -06 PROJECT NAME: L & R SERVICES INC. SITE ADDRESS: 4712 S 134 PL X Original Plan Submittal Response to Incomplete Letter # Response to Correction Letter # Revision # After Permit Issued DEPARTMENTS: 6 V BGAding Di3(sio�w P bli Worfci DE TERMINATION COORD COPY PLAN REVIEW /ROUTING SLIP IZ m fi 140-07 Fire revention Structural ION OF COMPLETENESS: (Tues., Thurs.) Complete Incomplete ❑ Comments: Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: TUES/THURS ROUTING: Please Route Structural Review Required ❑ No further Review Required DATE: Approved ❑ Notation: Documents/routing slip.doc 2 -28-02 REVIEWER'S INITIALS: APPROVALS OR CORRECTIONS: REVIEWER'S INITIALS: Approved with Conditions E Ala ii.1114 PPanning Division Permit Coordinator ❑ DUE DATE: 11-14 -06 Not Applicable ❑ DUE DATE: 12-12 -06 Not Approved (attach comments) ❑ DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: CITY OF TUKWILA Community Development Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 Permit Center /Building Division: 206 -431 -3670 Public Works Department: 206 - 433 -0179 Planning Division: 206 -431 -3670 STATE OF WASHINGTON) ss. COUNTY OF KING AFFIDAVIT IN LIEU OF CONTRACTOR REGISTRATION Er 1 /W1 S c )1 (please print 1. I have made application for a building permit from the City of Tukwila, Washington. 2. I understand that state law requires that all building construction contractors be registered with the State of Washington. The exceptions to this requirement are stated under Section 18.27.090 of the Revised Code of Washington, a copy of which Is printed on the reverse side of this Affidavit. I have read or am familiar with RCW 18.27.090. 3. 1 understand that prior to issuance of a building permit for work which is to be done by any contractor, the City of Tukwila must verify either that the contractor is registered by the State of Washington, or that one of the exemptions stated under RCW 18.27.090 applies. 4. In order to provide verification to the City of Tukwila of my compliance with this requirement, I hereby attest that after reading the exemptions from the registration requirement of RCW 18.27.090, 1 consider the work authorized under this building permit to be exempt under No. /1/ and will therefore not be performed by a registered contractor. I understand that I may be waiving certain rights that I might otherwise have under state law in any decision to engage an unregistered contractor to perform construction work. \applications\8.2004 affidavit In lieu of contractor registration states as follows: A PLICAN JJ PERMIT NO.: e- [r-g Signed and swom to before me this 294 day of Vanuuary ali-et 42 btu NOTARY PUBLIC in and for the t o of Washington, 2007 . Residing at Ain1 q County. Name as commissioned: Alice A. Deacy My commission expires: 6-/6- 48 18.27.090 Exemptions. This chapter shall not apply to: 1. 2. An authorized representative of the United States Govemment, the State of Washington, or any incorporated city, town, county, township, irrigation district, reclamation district or other municipal or political corporation or subdivision of this state; 3. Officers of the court when they are acting within the scope of their office; 4. Public utilities operating under the regulations of the utilities and transportation commission in construction, maintenance, or development work incidental to their own business; 5. Any construction, repair or operation incidental to the discovering or producing of petroleum or gas, or the drilling, testing, abandoning, or other operation of any petroleum or gas well or any surface or underground mine or mineral deposit when performed by an owner or lessee; 6. The sale or installation of any finished products, materials, or articles of merchandise which are not actually fabricated into and do not become a permanent fixed part of the structure; 7. Any construction, alteration, improvement or repair of personal property, except this chapter shall apply to all mobile, manufactured housing. A mobile /manufactured home may be installed, set up, or repaired by the registered or legal owner, by a contractor licensed under this chapter, or by a mobile /manufactured home retail dealer or manufacturer licensed under chapter 46.70 RCW; 8. Any construction, alteration, improvement, or repair carried on within the limits and boundaries of any site or reservation under the legal jurisdiction of the federal government; 9. Any person who only fumished materials, supplies, or equipment without fabricating them into, or consuming them in the performance of, the work of the contractor, 10. Any work or operation on one undertaking or project by one or more contractors, the aggregate contract price of which for labor and materials and all other items is less than $500.00, such work, or operations being considered as of a casual, minor, or inconsequential nature. The exemption prescribed in this subsection does not apply in all instance wherein the work or construction is only a part of a larger or major operation, whether undertaken by the same or a different contractor, or in which a division of the operation is made into tapplications\8 -2004 affidavit in lieu of contractor registration 11. Any construction or operation incidental to the construction and repair of irrigation and drainage ditches of regularly constituted irrigation districts or reclamation districts; or to farming, dairying, agriculture, viticulture, horticulture, or stock or poultry raising; or to clearing or other work upon land in rural districts for fire prevention purposes; except then any of the above work is performed by a registered contractor; 12. An owner who contracts for a project with a registered owner; contracts of amounts less than $500.00 for the purpose of the evasion of this chapter or otherwise. The exemption prescribed in this subsection does not apply to a person who advertises or puts out any sign or card or other device which might indicate to the public that he is a contractor, or that he is qualified to engage in the business of contractor, 13. Any person working on his own property, whether occupied by him or not, and any person working on his residence, whether owned by him or not but his exemption shall not apply to any person otherwise covered by this chapter who constructs an improvement on his own property with the intention and for the purpose of selling the improved property; Owners of commercial properties who use their own employees to do maintenance, repair, and alteration work in or upon their own properties; 15. A licensed architect or civil or professional engineer acting solely in his professional capacity, an electrician licensed under the laws of the state of Washington, or a plumber licensed under the laws of the state of Washington while operating within the boundaries of such political subdivision. The exemption provided in this subsection is applicable only when the licensee is operating within the scope of his license; 16. Any person who engages in the activities herein regulated as an employee of a registered contractor with wages as his sole compensation; 17. Contractors on highway projects who have been prequalifled as required by chapter 13 of the Laws of 1961, RCW 47.28.070 with the department of transportation to perform highway construction, reconstruction, or maintenance work. x