Loading...
HomeMy WebLinkAboutPermit D96-0013 - US COURTS - TENANT IMPROVEMENTCERTIFICATE OF OCCUPANCY CITY OF TUKWILA 6300 SOUTHCENTER BOULEVARD, SUITE 100 TUKWILA, WASHINGTON 98138 THIS CERTIFICATE ISSUED PURSUANT TO THE REQUIREMENT'S OF SECTION 307 OF THE UNIFORM BUILDING CODE .ICERTIFYING .THAT AT THE TIME OF ISSUANCE THIS STRUCTURE WAS IN COMPLIANCE WITH THE .VARIOUS ORDINANCE'S OF THE CITY' REGULATING BUILDING CONSTRUCTION OR USE AND ALL APPLICABLE CITY FIRE CODES: FOR. THE FOLLOWING: Ten.arnt: U.S:COURTS` Building Address: 14210 INTERURBAN AV S Parcel #:,3.36590 -188 Owner `FAIRWAY CENTER ASSOC. Occupancy: _OFFICE Occupancy Group: B Permit No: D96 -0013 Suite No: Occupant Load: "34 Type of Const: V -N TENANT' }EMPROVEMENT TO OFFICE WHICH.: ,INCLUDES ' CONSTRUCTION OF DEMISING WALLS SAND CONSTRUCTION OF' Eui BATHRO. M BUILDING FFICIAL //-,11-1‘ DATE THIS CERTIFICATE MUST BE CONSPICUOUSLY POSTED ON THE PREMISE; AAAAA *A*AAAAAAA* AAA** AAA *AAAAAA*AkAAA AltitAAAAAAA **AAAAAAAAAAAAAAA City of Tukwila (206) 431 -3670 Community Development / Public Works • 6300 Southcenter Boulevard, Suite 100 • Tukwila, Washington 98188 DEVELOPMENT PERMIT WARNING: IF CONSTRUCTION BEGINS BEFORE APPEAL PERIOD EXPIRES, APPLICANT IS PROCEEDING AT THEIR OWN RISK. Parcel No: Address: Suite No: Location: Category: Type: Zoning: Const Type: Gas /Elec.: • Units: Setbacks: Water: Wetlands: 336590 -1881 14240 INTERURBAN AV S ACOM DEVPERM C2 V -N 001 North: N/A .0 South: Sewer: Slopes: .0 N/A Y Contractor Licence No: MMISEI *094P5 Permit No: Status: Issued: Expires: D96 -0013 ISSUED 10/02/1996 03/31/1997 Occupancy: OFFICE UBC: 1994 Fire Protection: SPRINKLERED /AFA East: .0 West: .0 Streams: OCCUPANT U.S. COURTS 14210 INTERURBAN AV S, TUKWILA WA 98168 OWNER FAIRWAY CENTER ASSOC. C/0 R J HALLISSEY CO INC., 12835 BEL -RED RD STE 140, BELLEVUE WA CONTACT FRANK HEFFERNAN Phone: 206 821 -3383 12277 134 CT NE, REDMOND WA 98052 CONTRACTOR M M I SERVICES INC. Phone: 206 882 -3034 14907 NE 40, REDMOND WA 98052 ***************************************************** * * * * * * * * * * * * * * * * * * * * * * * * * * * * * *1 Permit Description: TENANT IMPROVEMENT TO OFFICE WHICH INCLUDES CONSTRUCTION OF DEMISING WALLS AND CONSTRUCTION OF A NEW BATHROOM FACILITY. ***************************************************** * * * * * * * * * * * * * * * * * * * * * * * * * * * * * *i Construction Valuation: $ 48,000.00 PUBLIC WORKS PERMITS: *(Water Meter Permits Listed Separate) Eng. Appr: Curb Cut /Access /Sidewalk /CSS: N Fire Loop Hydrant: N No: Size(in): .00 Flood Control Zone: N Hauling: N Start Time: End Time: Land Altering: N Cut: Fill: Landscape Irrigation: N Moving Oversized Load: N Start Time: End Time: Sanitary Side Sewer: N No: Sewer Main Extension: N Private: N Public: N Storm Drainage: N Street Use: N Water Main Extension: N Private: N Public: N ***************************************************** * * * * * * * * * * * * * * * * * * * * * * * * * * * * * *1 TOTAL DEVELOPMENT PERMIT FEES: $ 923.14 ***************************************************** * * * * * * * * * * * * * * * * * * * * * * * * * * * * * *i Permit Center Authorized Signature: Date do- --Ev - I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provision of any other state or local laws regulating construction or the performance of work. I am authorized to sign for and obtain this development permit. Signature: Print Name: Date: )6 j;-/ d, This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. CITY OF TUKWILA Address: 14240 INTERURBAN AV S Permit No: D96 -0013 Suite: Tenant: Status: I'S'SUED Type: DEVPERM Applied: 09/13/1996 Parcel #: 336590 -1831 Issued: 10/02 /1996 *•4* k*** k * * ** * **** k k•k****'k* k* * ******* ** k ** k*•k k** k* * *** k *•k * ** k* k k k k k+ k:k k A k* k k Permit Conditions: 1. No changes will be made to the plans unless approved by the Architect or Engineer and the Tukwila Building Division. 2. Plumbing permits shall be obtained •thr^ough the Seattle -King County Department of Public Health. Plumbing will be inspected by that -agency, including all gas piping (296- 4722).^ 3. Electrical permits shall, be obtained through the Washington State Division of Labor and Industries and all electrical work will • be inspected by that agency (248 - 6630). 4'. All mechanical work shall he•under separate permit issued by the City; of •Tukwila. 5. All permits, inspection records, and approved plans shall be avai fable: at the job site prior to the start of any con - struction.' These documents are to be maintained and avail- able until'final inspection approval is granted. 6. Any new.ceiiing grid and light fixture installation is. required to meet lateral bracing requirements for 'Seismic Zone 3. 7. Partition walls-attached to ceiling grid must be laterally braced if over'eight (S) • feet in length. 3. Any'exposed insulations backing Material shall have a Flame • Spread Rating of 25 or less, and material shall bear identi- fication.showing the fire performance rating thereof. 9. Provide illuminated exit sign at hallway door leading to stair enclosure. Also provide illuminated exit sign at door leading to waiting room. 10. All construction to be done in conformance with approved plans and requirements of the Uniform Building Code (1994 Edition) as amended,. Uniform Mechanical Code (1994 Edition), and Washington State Energy Code (1994 Edition). 11. There shall be 'no occupancy of the building(s) until the final inspection has been completed by the Tukwila Building Inspector. '• 12. A CERTIFICATE OF•OCCUPANCY WILL BE REQUIRED FOR THIS PERMIT. 13. Validity of Permit. The issuance of a permit or approval of plans, specifications,' and computations shall not be con- strued to be a permit for,, or an approval of, any violation of any of the provisions of the building code or of any other ordinance of the jurisdiction. No permit presuming to give authority to violate or cancel the provisions of this code shall be valid. CITY OF 'rUKWILA Permit Center 6300 Southcenter Boulevard, Suite 100 Tukwila, WA 98188 (206) 431 -3670 FOR STAFF USE ONLY Prod tct Nun' r: Permit Nurttbcr:, :DC4, " e c; j 3 Commercial / Multi - Family Tenant Improvement / Alteration Permit Application Application and plans must be complete In order to be accepted for plan review. Applications will not be accepted through the mall or facsimile. Project Name/Tenant: 0 C C)L 4 2L Valu of Construction: 4�: Site Address: City State/Zip: %4z 4c 11LLTG-l211 '13 ).- AVE S -rck 11A,53(or510 Tax Parcel Number: - et pb2P0 -cod • Phone: (2r.7.04-5,5 • q 2_C7 Fax #: 4r . 2_cr) LQ-j Property Owner/ arc -yin r : R.. n . l-kA(..ii f Street Address: City State/Zip: J) 5 Cam • I(t? EI.1_D. t2letiVie 9ftcC5 Contact Person: p.A is t-i. ill Phone: 571 • ?-)34o-Lal Street Address: City State/Zip: 17-9 - 13A- OP T , ME:, . Yz.lC�b•tXl(�.11D WA ciAnNa Fax #: ev7 I. zz 1 Contractor: MITYI 1 sp y I L� Phone: e z - 5034-- Street Address: City State /Zip: I(o 533 N e » T. 12EZ1v16,1►1 S2,., Fax #: 9 Z • ,r v?) Architect: Phone: Street Address: City State /Zip: _ ) 22. - 134 CJ T. t P�rw•�1� Fax #: 1 • 3Z l 3 Engineer: t.i 06, Phone: Street Address: City State /Zip: Fax #: Description of work to be done: 3)Th-! E F o1F1( E "1-E1- 1A14.T 1UAil iF A 4T• Existing use: ❑ Retail ❑ Restaurant ❑ Multi- family ❑ Warehouse El Hospital ❑ Church ❑ Manufacturing ❑ Motel /Hotel Office ❑ School /College /University ❑ Other Proposed use: ❑ Retail ❑ Restaurant ❑ Church ❑ Manufacturing ❑ School /College /University ❑ Multi- family ❑ Warehouse ❑Hospital ❑ Motel /Hotel gOffice ❑ Other Will there be a change of use? ❑ yes ,gk no If yes, extent of change: (Attach additional sheet if necessary) Will there be rack storage? ❑ yes Xkno Existing fire protection features: 71.,prinkiers automatic fire alarm ❑ none ❑ other (specify) Building Square Feet: [04-bc O5 existing Area of Construction: (sq. ft.) 3 t Will there be storage of flammable /combustible hazardous material Attach list of materials and storage location on separate 8 1/2 In the building? ❑ yes X 11 paper indicating quantities & Material Safety Data Sheets APPLICANT REQUEST FOR PUBLIC WORKS SITE/CIVIL PLAN REVIEW OF THE FOLLOWING: (Additional reviews may be determined by the Public Works Department) ❑ Channelization /Striping ❑ Land Altering 0 Cut cubic yds. ❑ Sanitary Side Sewer #: ❑ Storm Drainage ❑ Street Use ❑ Water Meter /Exempt #: Size(s): ❑ Water Meter /Permanent # Size(s): ❑ Water Meter Temp # Size(s): ❑ Miscellaneous ❑ Curb cut/Access /Sidewalk ❑ Flood Control Zone ❑ Hauling 0 Fill cubic yds. ❑ Landscape Irrigation ❑ Sewer Main Extension 0 Private 0 Public ❑ Water Main Extension 0 Private 0 Public 0 Deduct 0 Water Only Est. quantity: gal Schedule: Value of Construction - In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review - Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The building official may extend the time for action by the applicant for a period not exceeding 180 days upon written request by the applicant as defined In Section 107.4 of the Uniform Building Code (current edition). No application shall be extended more than once. Date application accepted: q- 13 q, Date application expires: 13 - ti-7 Application taken by: (Initials) CTPERMIT.DOC 7/9/96 ALL COMMERCIAL /MULTI -FA Y TENANT IMPROVEMENT /ALT MU E SUBMITTED WITH THE FOLL •� TION PERMIT APPLICATIONS ING: ➢ ALL DRAWINGS TO BE STAMPED BY WASHINGTON STATE LICENSED ARCHITECT, STRUCTURAL ENGINEER OR CIVIL ENGINEER N/A CI ALL DRAWINGS SHALL BE AT A LEGIBLE SCALE AND NEATLY DRAWN BUILDING SITE PLANS AND UTILITY PLANS ARE TO BE COMBINED SUBMITTED 71 Complete Legal Description ❑ Metro: Non - Residential Sewer Use Certification if there is a change in the amount of plumbing fixtures (Form H -13). Business Declaration required (Form H -10). Five (5) sets of working drawings, which include : ❑ Site Plan (including existing fire hydrant location(s) 1. North arrow and scale 2. Property lines, dimensions, setbacks, names of adjacent roads, any proposed or existing easements 3. Parking Analysis of existing and proposed capacity; proposed stalls with dimensions 4. Location of driveways, parking, loading & service areas 5. Recycle collection location and area calculations (change of use only) 6. Location and screening of outdoor storage (change of use only) 7. Limits of clearing /grading with existing and proposed topography at 2' intervals extending 5' beyond property's boundaries 8. Identify location of sensitive area slopes 20% or greater, wetlands, watercourses and their buffers (change of use only) 9. Identify location and size of existing trees that are located in sensitive areas and buffer (TMC 18.45.040), of those, identify by size and species which are to be removed and saved 10. Landscape plan with irrigation and existing trees to be saved by size and species (exterior changes or change of use only) 11. Location and gross floor area of existing structure with dimensions and setback 12. Lowest finished floor elevation (if in flood control zone) 13. See Public Works Checklist for detailed civil /site plan information required for Public Works Review (Form H- 9). Floor plan: show location of tenant space with proposed use of each room labeled Overall building floor plan with adjacent tenant use; identify tenant space use and location of storage of any hazardous materials; dimensions of proposed tenant space. Vicinity Map showing location of site Rack Storage: If adding new racks or altering existing rack storage, provide a floor plan identifying rack layout and all exit doors. Show dimensions of aisles, include dimensions of height, length, and width of rack. Structural calculations are required for rack storage eight feet and over. Indicate proposed construction of tenant space or addition and walls being demolished Construction details Sprinkler details - details of sprinkler hangers, specifically penetrations in structure, i.e., roof; size of water supply to sprinkler vault with documentation from contractor stating supply line will meet or exceed sprinkler system design criteria as identified by the Fire Department. Washington State Non - Residential Energy Code Date shall be noted on the construction drawings. SEPA Checklist - if intensification of use (check with Planning Department for thresholds). Attach plans, reports or other documentation required to comply with Sensitive Area Ordinance or other land use or SEPA decisions. Food service establishments require two (2) sets of stamped approved plans by the Seattle -King County Department of Public Health prior to submitting for building permit application. The Department of Public Health is located at 201 Smith Tower, Seattle, WA or call (206) 296 -4787. (Form H -5) Copy of Washington State Department of Labor and Industries Valid Contractor's License. If no contrac • i . s been selected at time of application a copy of this license will be require • OR submit Form H -4, "Affidavit in Lieu of Certificate of Contractor ". Building Owner /Authorized Agent If the applicant is other than the owner, registered architect/engineer, or contractor licensed by the State of Washington, a notarized letter from the property owner authorizing the agent to submit this permit application and obtain the permit will be required as part of this submittal I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND 1 AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER 0 A HO; 4 D AGENT: Date: cf 13 CJ Signature: ;' -" 'F Print name: lizALttc r- - - . Phone: gz 3393 Fax #: g2.1 3Z' Zoo Address car? 134, er hie -44.2.10 cu RE�CFETt�KWILA City /State /Zigiaxy r .e 1605 CTPERMIT.DOC 7/9/96 SEP 1 3 1996 PERMIT CENTER City of Tukwila John W. Rants, Mayor Fire Department TUKWILA FIRR !APARTMENT FINAL APPROVAL FORK Project Name L/• S- C o✓,-i S Thomas P. Keefe, Fire Chief Permit No. 096-00/3 Address L/ Q T Suite # a S �. Retain current inspection schedule Needs shift inspection Approved without correction notice Approved with correction notice issued Sprinklers: Fire Alarm: ' -+p.,, Hood & Duct: ^� Halon: Monitor: Pre -Fire: Permits: ized Si natur Author g ///lx 9c Date FINALAPP.FRM T.F.D. Form F.P. 85 Headquarters Station: 444 Andover Park East • Tukwila, Washington 98188 • Phone: (206) 575-4404 • Fax (206) 5754439 ****A**A*'****** A**• k***4*********• A*** 4 * * * * *:4 **tt * * * *:4* ** *k *4AAAi CITY OF TUKWILA, NA a � �O TRANSMIT * * * *A *A ** * *% * * *k * * ** *4 * * * * :4 * �l3*•:***: 5 *$4 * *,A* * *A$ * *'*•A**4 **4*4* **** TRANSMIT Number: 8960047/ Ama'.tnt: 361.89 09/13/96 16 :20 Payment Method: CHECK Notation: FERRARI DESIGN Init: Permit No: 096 -0013 Type: DEVPERM DEVELOPMENT PERMIT Parcel No: 336590.1891 Site Address: 14240 INTERURBAN AV S Total Fees: 923.14 This Payment 361.89 Total ALL Pmts: e361.99 Balance: 561.25 * ** **. 44*** k• k*** 4**.* 4*• kA*• k: l**** k*44** A * * * * *#**:t **•*•:S * * **k4A*4 *•4 ** Account Cods 000/345.830 Decription Amount PLAN CHECK - NONI ES 361.89 3174 09/16 9617 TOTAL 361.89 O *AA ** * *** AAA* ****'***•******4**•** A* 4 * *i *A* ** * ** *** * * * * * *AA* *AA* *4% CITY OF TUKWILA, WA TRANSMIT 4** 4**** * *4* **4 *t4 *A *•A *44*A4*44 * *4 * *AA *AAA **4A *A* *4k44444*4k* *i4** TRANSMIT Number: R9600487 Amount: 561,.25 10/02/96 11:23 Payment Method: CHECK Natation: MMI. SERVICES INC Init: SL.B 7 - Permit No: 096-0013 Type: DEVPERM DEVELOPMENT PERMIT Parcel No: 336590• -1881 Site Address: 14240 INTERURBAN AV S Total Fees: 923.14 This Payment 561.2; Total ALL Pints: 923.14 Balance: .00 ****4* 4•k ** *** *4 *4* *4 * * ** ** * * * * * * **4 *4444 **4* *44 ** *A *ttth t4 *�t• * *4A*** (account Code 000/322.100 ' 000!386.904 Description BUILDING - NONRES STATE BUILDING• SURCHARGE Amount '656../5 4.50 3640 10/02 9617 TOTAL 561.25 '--- 1 INSPECTION RECORD Retain a copy with permit INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98 Doi(0- Ooi3 PERMIT NO. 8 06)-43 -3670 Proiftet (1ovo1 5 Type of inspec sDate called: n:Fiit. i i _ 22.14, itirm iti_ra2Riz.8A4 Av Special instructions: Date wanted: 1 26 96 421.rn. Reuester:_f Ati_ed Phone No.: 'Approved per applicable codes. Corrections required prior to approval. Inspector: Date: I IS 5 $42.00 REINSPECTION FEE REQUIRED. Prior to inspec ion, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: Date: c 1 INSPECTION RECORD I Retain a copy with permit INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 PERMIT NO. 206) 431 -3670 Project:, l ` �,7.� Type of inspection: m ILJZ : � ,k , , I s Date called: 1'r Special inst uctions: Date wanted: Requester o A^ ,J-E1\. 3 Approved per applicable codes. Corrections required prior to approval. COMMENTS: 1 Q bPk 0 F11(44- Fi NPCI_- z Pr1 V■1247-' t CIF Snr -,4: Gt.A2, .JC, FoL gt t I G F1-1-S . OM( CAO-AFL- S f4€ WS 6 K.i i 14.cr (MA >L cS) Art..( 45 w ✓Lr Vp UN O.&" --- v..111 1.1P "gym• Ok -IN yv\■`,C IIJ rule/1,4-4.A 4...E. Eri .... f CA* (-(3) - 3tn(DS Inspector: �.it $42.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. CaII to schedule reinspection. Receipt No.: Date: INSPECTION RECORD Retain a copy with permit IN TION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 of, 0 PERMIT NO. (206) 431-3670 Projectoc 09 1......tf. C., Type of inspectiorhogitz Date called: Address: """ Special instructions: Date wanted: #... e4,9c (1:0 Requester: Phone No.: toApproved per applicable codes. MENTS: Corrections required prior to approval. Inspector: Date: //qc $42.00 REINSPECTIO r FEE REQUIR D. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: Date: INSPECTION NO. INSPECTION RECORD Retain a copy with permit CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 1 Oto -0D13 PERMIT NO. =�.+ (206) 431 -3670 Project' /1 :OlikaJ Type of inspectiormAm AEI ov ' mot) 4v s Date called: II_ --7_10 Special instructions: 6-TE, Z67.. Fl -I `, /ly_..P;, j� Date wanted: p _ C' " a.m: `_ D p.m. Requester. A` A Phone No.: td4g O pir4 Approved per applicable codes. C. +MENTS: Corrections required prior to approval. $42.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. CaII to schedule reinspection. Receipt No.: Date: INSPECYION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 INSPECTION RECORD Retain a copy with permit D .76-60/3 PERMIT NO. (206) 431 -3670 Pro'e t i� r� pe of i spection: _l, ( 11 Q ��•` Ad res -- ate called: Special instructions: €CQ,U. 51 CtS {°55iO�. ll 2,S2- I CS.-C"C.. CZS Date to :� to(69 a.m. p.m. R st r. erY:l /41le& PoneNo.:/ ((LL Approved per applicable codes. Corrections required prior to approval. COMMENTS: Inspecto //—d Add rots $42.00 REINSPEC ION FEE REQUIRED. Prior to inspection, fee must be praid at 6300 Southcenter Blvd., Suite 100. CaII to schedule reinspection. Date: Receip# No.: Date: .I • INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 INSPECTION RECORD Retain a copy with permit (206) 431 -3670 Pro ec • E) elk e f ' s c I Typit P p N ib F )1A67 dre Zo lortatesiw i S Date called: f 0- 28— 16 Special instructions: 2 5 2 Date wanted: G �j> to - Z f- 14O t1=y' Requester: K e-\ Phone No.: /Do — of ( proved per applicable codes. Corrections required prior to approval. COMMENTS: Inspector: Date: tqc:, $42.00 REINSPECTION FEE REQUIRED. Prior to Inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: Date: INSPE TIO �VO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 INSPECTION RECORD i� Retain a copy with permit S/ t (? 6)1'3 PERMIT NO. (206) 431 -3670 Project: i 6 n Ot& r Type of 'ns ctq, ignf g Address:' , (7.40 ,�0 vuV Date cal ed: /01 ?i 3 Special instructions: Date wanted: /2415, m. Requester: t/ „ 4 f -... Phone No.: cp47 _ -50E3 Approved per applicable codes. 1:g1 Corrections required prior to approval. COMMENTS: Inspector: Ow Date: 001 24((q(.0 $42.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Soutlicenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: Date: INSPECTION NO. INSPECTION RECORD Retain a copy with permit CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 Proiq y5 Coot/1-5 Type ' YPeo f Adore L/6 I /v5_ Special instructions: D910-o6►3 PERMIT NO. (206) 431 -3670 I rrt ii)G; Date called: /V - /7„ 96 Date wanted: Requester: orti Irr6oti-305.-3 Approved per applicable codes. [Corrections required prior to approval. COMMENTS: ) rtco11) Ihi ( 1 S St,l k ► P Lu14.13/ niC7 AN' 0 C� .-111-4 C.41..... APrW c. . z) LJJA -o— &LA Gc47T W /L'(1 u t OD,. is __1) 1- kA-11-'0 2-4 9 f- lit— Cb •Oo rL. 13T1 1 9 TUA AO f ,7741-)3vvi-7 onig kJ F-z,itid fl...- P I ,i J M jl4 f=r (Le sTd P . r• Inspector: Date: �u 21196 $42.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. CaII to schedule reinspection. Receipt No.: Date: 4 intmr•TAO Non- Residential Sewer Use Certification (To be completed for all new sewer connections, reconnections or change of use of existing connections. This form does not apply to repairs or replacements of existing sewer connections.) Pursuant to Metro Council Resolution Nos, 5719 and 5968, all sewer customers who establish a new service which uses metropolitan sewage facilities after February 1, 1990 shall be subject to a capacity charge. The Metro Council has established the amount of the charge at seven dollars ($7.00) per month per residential customer or residential customer equivalent for a period of fifteen years. The purpose of the charge 1t to recover costs of providing sewage treatment capacity for new sewer customers. The charge is collected semi•annuatly. All future billings can be prepaid at a discounted amount. Questions regarding the capacity charge or this form should be referred to Metro at 684.1740. vqi1 0013 (Please print or Owner's Nam Property Legal Address: Subdivision . Plat Alloy street l4 f -RUe Au S— 6 pe) E (Last, first. Mlddie Ini11 City, Stale, 2Ip. �i A Y t a.C�11 Q 1��► - - -- Owner's Phone Number .a.) ASS • ` Q2 Owner's Mailing Address: (if different from above) 12.5 �FzCJ �D A,o A. Fixture Units Number of Fixtures x Fixture Units =Total Fixture Units (Public or Private) Kind of Fixture Finyrp WA, — No. of Fixtures Taal Future Unite Public Ptlrete Public Private Bathtubs and /or shower 4 2 Dental units or lavatory 1 — Dishwasher, oommerciel 4 — Drin� king lountain (each head) 1 — _ HorA bibb or 6H1 cock 0 3 Laundry tub or clotheswasher 4 2 Sink, bar or lavatory 2 Sink, clinic, hushing 10 -. Sink, kitchen 4 2 l 4 Sink, other 4 2 91uh wsuch, ulrolsr bjray 4 - Urinal, flush tank 3 — Urinal, pedestal 10 — Urinal, wall or stall 5 — Water closet tank • 5 3 l `j -ffileTaloset, flush valve 10 . t3 Total Fixture Units 1 1 Residential Customer Equivalents (FICE) 20 fixture units equal 1.0 RCE Total No. of Fixture Units 20 .55 RCE AvaNiNY AWN f'y�jy.X. Party to be Billed (if different from owner) t.7 Party's Mailing Address: (if different horn properly address) uIPt City or Sewer District 0 t 1 A Date of Connection Side Sewer Permit # U. Other Wastewater Flow ('...) (in addition to Fixture Units identifi Type of Facility/Process: d in Section A) Estimated Wastewater Discharge: Gallons/day Residential Customer Equivalents (RCE): 187 gallons per day equals 1.0 RCE Total Discharge sgal/day) 187 RCE C. Total Residential Customer Equivalents: (add A & B) A B .55 . 55 ] RCE 1 certify that the information given is correct. I understand that the capacity charge levied will be based on this irformation and arty deviation will require resubmission of corrected data for determination of a r;v'sed capacity charge. Signature of Own Representative Print Name of Owner/ Representative ¶IG j• Ag �. Date 1'3 1110 Envelope Summary 1994 Waskington State Nonresidential Energy Code Compliance Forms Climate Zone ENV -SUM June, 1995 Project Info Project Address Date g A I i (eD For Building Depar me Use IYI(O.00' s 149 44:11- 1 14;.V.,444 AAvE 5. r UIr W` LP, • • Concrete/Masonry Option � paL p Applicant Name: 1:)%G.]�� 'Applicant Address:122 1341C -T 14 ,Nip Applicant Phone: C2.0( di , Ap (Project Description J❑ New Building 0 Addition Iteration ❑ Change of Use Compliance Option 0 Prescriptive 0 Component Performance (See Decision Flowchart (over) for qualifications) D ENVSTD D Systems Analysis Space Heat Type Q Electric resistance 0 All other (see over for definitions) Glazing Area Calculation Note: Below grade walls may be included in the Gross Exterior Wall Area if they are insulated to the level required for opaque walls. Total Glazing Area Electronic version: these values are automatically taken from ENV -UA -1. (rough opening) Gross Exterior (vertical & overhd) divided by Wall Area times 100 equals % Glazing — X 1 00 = • Concrete/Masonry Option Q yes Check here if using this option and if project meets all requirements for the Concrete/Masonry Option. See Decision Flowchart (over) for qualifications. Enter requirements for each qualifying Q no assembly below. Envelope Requirements (enter values as applicable) Fully heated/cooled space Minimum Insulation R- values Roofs Over Attic All Other Roofs Opaque Walls Below Grade Walls Floors Over Unconditioned Space Slabs -on -Grade Radiant Floors Maximum U- factors Opaque Doors Vertical Glazing Overhead Glazing Maximum SHGC (or SC) Vertical /Overhead Glazing Semi- heated space` Minimum Insulation R- values Roofs Over Semi- Heated Spaces` 'Refer to Section 1310 for qualifications and requirements Notes: E ./e,..0pe_ 15 E i asi-I DACr1 Tb (C-'- fllttt t,.l L w_i_.\ i 4.(nez t3� 2Y— u413129— m- IS pa-r. Opaque Concrete /Masonry Wall Requirements Insulation on interior - maximum U- factor Is 0.19 Insulation on exterior or integral - maximum U- factor is 0.25 If project qualifies for Concrete /Masonry Option, list walls with HC 2 9.0 Btu /ft=-°F below (other walls must meet Opaque Wall requirements). Use descriptions and values from Table 20 -5b in the Code. Wall Description (Including insulation R -value & position) U- factor • nvelope Summary (b.ck) 1994 Washington State Nonresidential Energy Code Compliance Forms 1994 Washington State Nonresidential Energy Code Compliance Form Climate Zone 1 ENV -SUM June, 1995 Decision Flowchart for Prescriptive Option Use this flowchart to determine if project qualifies for the optignal Prescriptive Option. If not either the Component Performance or Systems Analysis Options must be used. 1302 Space Heat Type: For the purpose of determining building envelope requirements, the following two categories comprise all space heating types: Other: All other space heating systems including gas, solid fuel, oil, and propane space heating systems and those systems listed in the exception to electric resistance. (continued at right) Electric Resistance: Space heating systems which use electric resistance elements as the primary heating system including baseboard, radiant, and forced air units where the total electric resistance heat capacity exceeds 1.0 W/ft2 of the gross conditioned Floor area. Exception: Heat pumps and terminal electric resistance heating In variable alr volume distribution systems. Electric Resistance Heat? , All walls R -11 sulation? Masonry all Criteria OK? (below) no Masonry all Criteria OK? (below) All walls R -19 sulation2 no <40% lazing yes no <25% lazing <20% dazing no All Insulation installed? Opaque Walls R -11 Below grade walls (ext) R -10 Below grade walls (othr) R -11 Roofs over attics R -30 All other roofs R -21 Floors over uncond.sp. R -19 Slabs-on-grade R -10 Radiant floors R -10 Opaque doors U -0.60 Glazing Criteria Met? Glazing Vert OH Area % U U SHGC 00.15% 0.90 1.45 1.00 15-20% 0.75 1.40 1.00 20.30% 0.60 1.30 0.65 30.40% 0.50 1.25 0.45 no yes Alt insulation installed? Opaque Walls R -11 Masonry walls(int) U -0.19 Masonry walls(other) U -0.25 Below grade walls (ext) R -10 Below grade walls (otter) R -11 Roofs over attics R -30 All other roofs R -21 Floors over uncond.sp. R -19 Slabs-on-grade R-10 Radiant floors R-10 Opaque doors U -0.60 Glazing Criteria Met? Glazing Vert OH Area •% U U SHGC 00.10°% 0.90 1.45 1.00 10.15% 0.75 1.40 1.00 15-20% 0.65 1.30 0.80 20-25% 0 60 1.30 0.65 yes All Insulation Installed? Opaque Walls R -19 Masonry walls(int) U•0.19 Masonry walls(other) U -0.25 Below grade walls (ext) R -10 Below grade walls (otter) R -19 Roofs over attics R -38 All other roofs R -30 Floors over uncond. R -30 Slabs-on-grade R -10 Radiant floors R -10 Opaque doors U-0.60 Glazing Criteria Met? Glazing Vert OH Area % U U SHGC 00-20% 0 40 0.80 1.00 yes Alt Insulation Installed ?' Opaque Walls R -19 Below grade walls (ext) R-10 Below grade walls (otter) R -19 Roofs over attics R -38 AIt other roofs R -30 Floors over uncond. R -30 Stabs -on -grade R -10 Radiantfloors R -t0 Opaque doors U -0.60 Glazing Criteria Met? Glazing Vert OH Area % U U SHGC 00.20% 0.40 0.80 1.00 1r Prescriptive Path Allowed Component Performance or Systems Analysis Required no Concrete/Masonry Option* Wall Heat Capacity (HC) Assembly Description Assy.Tag HC** Area (sf) HC x Area Totals Area weighted ;(C: divide total of (110 x area) by Total Area if the area weighted heat capacity (HC) of the total above grade wall is a minimum of 9.0, the Concrete Masonry Option may be used. For framed walls, assume HC =1.0 unless calculations are provided; for all other walls, use Section 2009. 1994 Washington State Nonresidential Energy Code Compliance Form Envelope UA Calculations Climate Zonel ENV -UA 1994 Washington Stab Nonresidential Energy Code Compliance Forms June, 1995 Project Address Date . Space Heat Type 0 Electric resistance 0 All other For Building Department Use Glazing Area as % gross exterior wall area Prop. I Max.Target Concrete/Masonry Option 0 Yes 0 No Notes: If glazing area exceeds maximum allowed In Table, then calculate adjusted areas on back (over). If Concrete/Masonry Option Is used, Target U- factors, SHGC and Glazing % will be different than shown below. Refer to Table 13-1 for correct values. Building Component List components by assembly ID & page # Proposed UA U- factor x Area (A) = UA (U x A) Target UA U- factor x Area (A) = UA (U x A) DI € 'g > 5 U= Plan ID: U= Plan ID: U= Plan ID: U= Plan ID: U= Plan ID: U= Plan ID: U= Plan ID: Glazing % Electric Resist Other Heating 0.15% :::...:: : ,: 0.40 ...............::::0.90: >154096: 0.'40 ' :::::::::0.75:::.:: 20-30% not allowed ........... 0.60 ' ' >30-40%:-• not 'allowed 0.50 .................. ............................... ::(see Table 13=1. for Conc/Masonry :values) I Overhead Glazing Over Attics U= Plan ID: U= Plan ID: U= Plan ID: U= . Plan ID: Glazing %:Electric Resist.:: Other Heating :'0-1596':: :; 0.80. 1.45 :::.. :. �15 =20% ::. :: 0.80 ::.::.::.: : „.140, . ; i. ?20 -30% r ::not allowed :.:1..30 530- 40 %... not allawed 1.25.:.. (see : Table13- 1' for Conc/Masonry values) ::. Oth.Roofs U= Plan ID: U= Plan ID: U= Plan ID: U= Plan ID: w a 8 0 U= Plan ID: U= Plan ID: U= Plan ID: _ Electric:Resist.....Other Heating ................. :.:::..:.:.0.60 0.60 :: : w 8 t> o: R= Plan ID: R= Plan ID: R= Plan ID: :.:Electric:ResiSt : Other Heating . :::::: :::0.031 0.036 •:: N 8 0 cc R= Plan ID: R= Plan ID: R= Plan ID: Electric.Resist. • Other :Heating, : 0. 034 :: ,,::::.:.0.050 :::. IOpaque Walls* R= Plan ID: R= Plan ID: R= Plan ID: R= Plan ID: R= Plan ID: R= Plan ID: R= Plan ID: * *Note: sum of Target Areas here should equal Target Opaque Wall Area (see back) ** ** ** :.:: Electric Resist. Other Heating Ordinary :: :: 0.062 ..................0:14........ Metal stud '.. ": " 0,1:1 0 :14. Conc(int), : :..: 0.1.9 0.19 Conc(oth) • • ' 0.25 ” " " " "' . "'0.25 :1:::::: in o g Plan m 0 R= Plan ID: R= Plan ID: R= ID: Note: If insulated to levels required for opaque walls, list above with opaque walls t;Iectric Resist, Other Heating: ;Ordinary 0.062. 0.1.4 Metal stud 0.11 0.1.4 IFloors Over Uncond. Sp. R= Plan ID: R= Plan ID: R= Plan ID: R= Plan ID: E.ectrio.Resist.. Other:Heating; 0.029 ' 0.056 ... g N o, R= Plan ID: _ Plan ID: R= Plan ID: R= Plan ID: Electric Resist. Other Heating F=0.54 F =0.54...:. ""(see Table .130: for radlant :floor .Values) *For CMU walls, indicate core Insulation material. For compliance: Totals Totals) 1) Proposed Total Area shall equal Target Total Area, and 2) Proposed Total UA shall not exceed Target Total UA. 1994 Washington State Nonresidential Energy Code Compliance Form Climate Zone 1 ENV -SHGC 1994 Washington State Nonresidential Energy Code Compliance Forms June, 1995 Vertical Glazing Ust components by assembly ID & page 0 Proposed SHGC SHGC' x Area (A) = SHGC x A Target SHGC SHGC x Area (A) = SHGC x A rn 2 ID: ID: ID: ID: ID: ID: Glazing % 0-20% .:.:...........1:Q0::: >20- 30% ..... >30;40% .....not (see:Table:13 Electric Resist, :;:' not allowed ;:::r allowed :::.:'' -1 for ConclMasonry Other Heating ::::::1.00.: :: 0.65 ': ' 0.45 values) 'Note: Manufacturer's SC may be used in lieu of Totals For compliance: 1) Proposed total area shall equal Target Total Totals shall Area, and 2) Proposed Total SHGC not exceed Target Total SHGC. Overhead Glazing List components by assembly ID & page 0 Proposed SHGC SHGC' x Area (A) = SHGC x A Target SHGC SHGC x Area (A) = SHGC x A Overhead Glazing • ID: ID: ID: ID: ID: ID: - ' _ Glazing % Electric Resist. ;Other. Heating. .... a2o�:; :` :. �;oo ; : ; :: 1.00 >20 -30% : : not allowed :::..: 0.65 ?'30-40°16 : :::: not allowed ; ;:.:::::0.45 (see Table:13 -1 for ConclMasonry values) 'Note: Manufacturer's SC may be used in lieu of SHGC. Totals' For compliance: Totals' - 1) Proposed total area shall equal Target Total Area, and 2) Proposed Total SHGC shall not exceed Target Total SHGC. Target Area Adjustment Calculations If the total amount of glazing area as a % of gross exterior wall area (calculated on ENV•SUM1) exceeds the maximum allowed in Table 13-1, then this calculation must be submitted Use the resulting areas in the Target UA and SHGC calculations above. Glazing Area Opaque Area Proposed Areas: Numbered values are used in calculations below. Roofs over Attics Other Roofs Walls OG= OG= VG= Gross Exterior Wall Max Glazing Area Area X (Table 13.1) 40.03 l 100 Target OG Area in Roofs over Attics Roofs over Attics Other Roofs Walls ti' lesser Max OG Remaining 1 Maximum Target Glazing Area Target OG Area in Other Roofs lesser a ue Area �l Target OG Area Opaque p q + Proposed OG Area Note: OG = overhead glazing VG = vertical glazing Target VG Area =1 I Target O a ue Area Proposed Opaque Area Proposed VG Area Target VG Area Target Opaque Area lTarget Areas OK Note: If there is more than one type of wall, the Target VG Area may be distributed among them, and separate Target Opaque Areas found. If the Target Areas for Opaque Walls listed on the front must equal the total calculated here. For Target OG's. the lesser values are used both here and below. + Target values in shaded boxes are used in the applicable Target UA calculations on the front. Target VG Area and Total Target OG Area are also used in the applicable Target SHGC calculations above. 1994 Washington State Nonresidential Energy Code Compliance Form Building Permit Plans hecklist 1994 Washington State Energy Code Compliance Forms ENV -CHK June, 1995 Project Address . 'Date The following information is necessary to check a building permit application for compliance with the building envelope requirements in the Washington State Nonresidential Energy Code. Applicability , I (yes, no, n.a.) Code Section Component Information Required q Location I on Plans 1 Building Department Notes GENERAL R EQUIREMENTS (Sections 1301 -1314) 1301 Scope Unconditioned spaces identifed on plans it allowed 1302 Space heat type: If "Other", indicate on plans that electric resistance heat is not allowed 1310.2 Semi - heated spaces Semi - heated spaces identified on plans if allowed 1311 Insulation 1311.1 Insul. installation Indicate densities and clearances 1311.2 Roof /ceiling insul. Indicate R -value on roof sections for attics and other roofs; Indicate clearances for attic insulation; Indicate baffles if eave vents installed; Indicate lace stapling of faced batts 1311.3 Wall insulation Indicate R -value on wall sections; Indicate face stapling of faced batis; Indicate above grade exterior insulation Is protected; Indicate loose -fill core insulation for masonry walls as necoss; Indicate heat capacity of masonry walls if masonry option is used or if credit taken in ENVSTD; ' 1311.4 Floor insulation Indicate R -value on floor sections; Indicate substantial contact with surface; Indicate supports not more than 24" o.c.; Indicate that insulation does not block airflow through foundation vents 1311.5 Slab-on-grade floor Indicate R -value on all section or foundation detail; Indicate slab insulation extends down vertically 24" from top; Indicate above grade exterior insulation is protected 1311.6 Radiant floor Indicate R -value on wall section or foundation detail; Indicate slab insulation extends down vertically 36" from the top; Indicate above grade exterior insulation is protected; Indicate insulation also under entire slab where req'd. by Official 1312 Glazing and doors Provide calculation of glazing area (including both vertical vertical and overhead) as percent of gross wall area 1312.1 U- factors Indicate glazing and door U- factors on glazing and door schedule (provide area - weighted calculations as necessary); Indicate if values are NFRC or default, if values are default then specify frame type, glazing layers, gapwidth, low -e coatings, gas fillings 1312.2 SHGC & SC Indicate glazing solar heat gain coefficient or shading coefficient on glazing schedule (provide area - weighted calculations as necessary) 1313 Moisture control 1313.1 Vapor retarders Indicate vapor retarders on warm side 1313.2 Roof /ceiling vap.ret. i Indicate vapor retarder on roof section; Indicate vap. retard. with sealed seams for non -wood struc. 1313.3 Wail vapor retarder Indicate vapor retarder on wall section 1313.4 Floor vapor retarder Indicate vapor retarder on floor section 1313.5 Crawl space vap. rel. Indicate six mil black polyethylene overlapped 12" on ground 1314 Air leakage 1314.1 Bldg. envel. sealing Indicate sealing, caulking, gasketing, and weatherstripping 1314.2 Glazing /door sealing Indicate weatherstripping 1314.3 Assemb. as ducts Indicate sealing, caulking and gasketing PRESCRIPTIVE /COMPONENT PERFORMANCE (Sections 1320 -23 or 1330 -34) Envelope Sum. Form 'Completed and attached. Provide component performance worksheet if necessary Provide ENVSTD screen 1 output if necessary It "no" is shown for any question, provide explanation: 1994 Washington State Nonresidential Energy Code Compliance Form Building Permit Plans Checklist ENV -CHK 1994 Washington State Energy Code Compliance Forms June, 1995 Envelope - General Requirements 1311 Insulation 1311.1 Installation Requirements: All insulation materials shall be installed according to the manufacturer's instructions to achieve proper densities, maintain clearances, and maintain uniform R- values. To the maximum extent possible, insulation shall extend over the full component area to the Intended R- value. 1311.2 Roof /Ceiling Insulation: Open -blown or poured loose -fill insulation may be used In attic spaces where the slope of the ceiling Is not more than 3/12 and there is at least thirty inches of clear distance from the top of the bottom chord of the truss or ceiling joist to the underside of the sheathing at the roof ridge. When eave vents are installed, baffling of the vent openings shall be provided so as to deflect the incoming air above the surface of the insulation. Where lighting fixtures are recessed into a suspended or exposed grid ceiling, the roof /ceiling assembly shall be insulated in a location other than directly on the suspended ceiling. Exception: Type IC rated recessed lighting fixtures. Where installed in wood framing, faced batt Insulation shall be face stapled. 1311.3 Wall Insulation: Exterior wall cavities isolated during framing shall be fully insulated to the levels of the surrounding walls. When installed in wood framing, faced batt insulation shall be face stapled. Above grade exterior insulation shall be protected. 1311.4 Floor Insulation: Floor insulation shall be installed in a permanent manner in substantial contact with the surface being insulated. Insulation supports shall be installed so spacing is not more than twenty - four inches on center. Installed Insulation shall not block the airflow through foundation vents. 1311.5 Slab-On-Grade Floor: Slab -on -grade insulation installed inside the foundation wall shall extend downward from the top of the slab a minimum distance of twenty-four inches or to the top of the footing, whichever is less. Insulation installed outside the foundation shall extend downward a minimum of twenty-four inches or to the frostline, whichever Is greater. Above grade insulation shall be protected. Exception: For monolithic slabs, the insulation shall extend downward from the top of the slab to the bottom of the footing. 1311.6 Radiant Floors (on or below grade): Stab -on -grade insulation shall extend downward from the top of the slab a minimum distance of thirty-six inches or downward to the top of the footing and horizontal for an aggregate of not less than thirty-six inches. If required by the building official where soil conditions warrant such Insulation, the entire area of a radiant floor shall be thermally isolated from the soil. Where a soli gas control system Is provided below the radiant floor, which results in increased convective flow below the radiant floor, the radiant floor shall be thermally isolated from the sub -floor gravel layer. 1312 Glazing and Doors 1312.1 Standard Procedure for Determination of Glazing and Door U- Factors: U- factors for glazing and doors shall be determined, certified and labeled in accordance with Standard RS -31 by a certified Independent agency licensed by the National Fenestration Rating Council (NFRC). Compliance shall be based on Model Size AA or BB. Product samples used for U- factor determinations shall be production line units or representative of units as purchased by the consumer or contractor. Unlabeled glazing and doors shall be assigned the default U- factor In Section 2006. 1312.2 Solar Heat Gain Coefficient and Shading Coefficient: Solar Heat Gain Coefficient (SHGC), shall be determined, certified and labeled in accordance with the National Fenestration Rating Council (NFRC) Standard by a certified, Independent agency, licensed by the NFRC. Exception: Shading coefficients (SC) shall be an acceptable alternate for compliance with solar heat gain coefficient requirements. Shading coefficients for glazing shall be taken from Chapter 27 of Standard RS-27 or from the manufacturer's test data. 1313 Moisture Control 1313.1 Vapor Retarders: Vapor retarders shall be installed on the warm side (in winter) of insulation as required by this section. Exception: Vapor retarder installed with not more than 1/3 of the nominal R -value between it and the conditioned space. 1313.2 Roof /Ceiling Assemblies: Roof /ceiling assemblies where the ventilation space above the Insulation is less than an average of twelve inches shall be provided with a vapor retarder. Roof /ceiling assemblies without a vented airspace, where neither the roof deck nor the roof structure are made of wood, shall provide a continuous vapor retarder with taped seams. Exception: Vapor retarders need not be provided where all of the insulation is installed between the roof membrane and the structural roof deck. 1313.3 Walls: Walls separating conditioned space from unconditioned space shall be provided with a vapor retarder. 1313.4 Floors: Floors separating conditioned space from unconditioned space shall be provided with a vapor retarder. 1313.5 Crawl Spaces: A ground cover of six mil (0.006 inch thick) black polyethylene or approved equal shall be laid over the ground within crawl spaces. The ground cover shall be overlapped twelve inches minimum at the joints and shall extend to the foundation wall. Exception: The ground cover may be omitted In crawl spaces it the crawl space has a concrete slab floor with a minimum thickness of three and one -half inches. 1314 Air Leakage 1314.1 Building Envelope: The requirements of this section shall apply to building elements separating conditioned from unconditioned spaces. Exterior joints around windows and door frames, openings between walls and foundation, between walls and roof and wall panels; openings at penetrations of utility services through walls, floors, and roofs; and all other openings in the building envelope shall be sealed, caulked, gasketed, or weatherstripped to limit air leakage. 1314.2 Glazing and Doors: Doors and operable glazing separating conditioned from unconditioned space shall be weatherstripped. Fixed windows shall be tight fitting with glass retained by stops with sealant or caulking all around. Exception: Openings that are required to be fire resistant. 1314.3 Building Assemblies Used as Ducts or Plenums: Building assemblies used as ducts or plenums shall be sealed, caulked, and gasketed to limit air leakage. 1994 Washington State Nonresidential Energy Code Compliance Form Mechanical Summary MECH -SUM 1994 Washington State Nonresidential Energy Code Compliance Forms June, 1995 Project Info Project Address 42.46 1 `► 1 AVER tJ � V►► Date 97i /q Co IC_ L.I i For Building Dept. Use Total CFM Applicant Name: 1( flu C2 (l LAP ApplicantAddress:122..44- 1. 14CpT utu Applicant Phone: R-e AYVILr ln W A E5ZI • 2 :_?% - Project Description Briefly describe mechanical system type and features. Tb 1! G Y%- 11 t 1�' paatt„ lT. Compliance Option Q Simple System Q Complex System Q Systems Analysis (See Decision Flowchart (over) for qualifications. Use separate MECH -SUM for simple & complex systems.) Equipment Schedules The following information is required to be incorporated with the mechanical equipment schedules on the plans. For projects without plans, fill in the required information below. Cooling Equipment Schedule Equip. ID Brand Name' Model No.' Capacity2 Btu/h Total CFM OSA CFM or Econo? SEER or EER IPLV3 Location • • Heating Equipment Schedule Equip. ID Brand Name' Model No.' Capacity2 Btu /h Total CFM OSA cfm or Econo? Input Btuh Output Btuh Efficiency' • Fan Equipment Schedule Equip. ID Brand Name' Model No.' CFM SP' HP /BHP Flow Controls Location of Service • 'If available. 2 As tested according to Table 14-1, 14-2 or 14-3. ' If required. ' COP, HSPF, Combustion Efficiency, or AFUE, as applicable. 5 Flow control types: variable air volume(VAV), constant volume (CV), or variable speed (VS). 1994 Washington State Nonresidential Energy Code Compliance Form Mechanical Summary back) MECH -SUM System Description See Section 1421 for full description of Simple System qualifications. If Heating/Cooling or Cooling Only: • Constant vol? 0 Air cooled? .Q Packaged sys? E] <54,000 Btuh 0 Economizer Included? or 1900 cfm? II Split system? If Heating Only: 0 <5000 cfm? 0 <70% outside air? Decision Flowchart Use this flowchart to determine if project qualities for Simple System Option. If not, either the Complex System or Systems Analysis Options must be used. System Type eating/Cooling or Cooling Only onstan olume Heating Only it Cooled? <5000 cfm? no Reference Sec. 1421 <70% OA no ackage• yes tem no 54,000 Btu 1900 cfm Split tem? 54,000 Btuh 1900 cfm Simple System Allowed Reference Sec. 1420, Use Complex System Reference Sec. 1430 Complex Systems Refer to MECH -COMP Mechanical Complex Systems for assistance in determining which Complex Systems requirements are applicable to this project. • 1994 Washington State Nonresider'' ' Energy Code Compliance Form Lighting Summary LTG -SUM 1994 Washington State Nonresidential Energy Code Compliance Forms June, 1995 Project Info Project Address 14.Z4c) 1Lor elit .L A j, �-! . Date q Ai i `i co T11V- 4.1 1, LiNc WA Covered Parking For Building Department Use 0.2 W/ft2 'Applicant Name: p L t(. caecuip, Open Parking Applicant Address: 12.244- 1 ", 1 me top \\ Applicant Phone: Z/I.✓ i , 3Da..2, Project Description ❑ New Building ❑ Addition %Alteration Compliance Option 0 Prescriptive 0 Lighting Power Allowance 0 Systems Analysis (See Qualification Checklist (over). Indicate Prescriptive & LPA spaces clearly on plans.) Alteration Exceptions (check appropriate box) ❑ No changes are being made to the ighting Less than 60% of the fixtures are new, and installed lighting wattage is not being increased Maximum Allowed Lighting Wattage (Interior) Location (floor /room no.) Occupancy Description Allowed Watts per ft2 " Area in ft2 Allowed x Area Covered Parking 0.2 W/ft2 Open Parking 0.2 W/ft2 Outdoor Areas 0.2 W/fte " From Table 15 -1 (over) - document all exceptions on form LTG -LPA Total Allowed Watts Proposed Lighting Wattage (Interior) (May not exceed Total Allowed Watts for Interior) Location (floor /room no.) Fixture Description Number of Fixtures Watts/ Fixture Watts Proposed Covered Parking 0.2 W/ft2 Open Parking 0.2 W/ft2 Outdoor Areas 0.2 W/fte Total Proposed Watts may not exceed Total Allowed Watts for Interior Maximum Allowed Lighting Wattage (Exterior) Total Proposed Watts Location Description Allowed Watts per ft2 or per If Area in ft2 (or If for perimeter) Allowed Watts x ft2 (or x If) Covered Parking 0.2 W/ft2 Open Parking 0.2 W/ft2 Outdoor Areas 0.2 W/fte Bldg. (by facade) 0.25 W/ft2 Bldg. (by perim) 7.5 Wilf Note: for building exterior, choose either the facade area or the perimeter method, but not both) Total Allowed Watts Proposed Lighting Wattage (Exterior) (May not exceed Total Allowed Watts for Exterior) Location v Y Fixture Description Number of Fixtures Watts/ Fixture Watts Proposed Total Proposed Watts may not exceed Total Allowed Watts for Exterior Total Proposed Watts 1994 Washington State Nonresidential Energy Code Compliance Form Lighting Summary (back) LTG -SUM 1994 Washington Slate Nonresidential Energy Code Compliance Forms June. 1995 Prescriptive Spaces Occupancy: 0 Warehouses, storage areas or aircraft storage hangers 0 Othe • r Qualification Checklist Note: If occupancy type is 'Other and fixture answer is chocked, the number of fixtures in the space is not limited by Code. Clearly indicate these spaces on plans. If not qualified, do LPA Calculations. Lighting Fixtures: a Check here if at least 95% of fixtures in the space meet all four criteria: 1. Fixtures are fluorescent, non - lensed, with only one or two lamps, and 2. Lamps are T -5, T -6, T -8 or PL, and 3. Lamps are 5 -50 Watts, and 4. Ballasts are electronic ballasts Table 15 -1 Unit Lighting Power Allowance (LPA) for Interior Lighting Use' LPA2 (WIft2) Use' LPA2 (W/ft2) Painting, welding, carpentry, machine shops 2.3 Police and fire stations° 1.2 Barber shops, beauty shops 2 Atria (atriums) 1 Hotel banquet/conference/exhibition hal13.4 2 Assembly spaces °, auditoriums, gymnasia°, theaters 1 Laboratories 2 Process plants 1 Aircraft repair hangars 1.5 Restaurants /bars° 1 Cafeterias, fast food establishments° 1.5 Retail A'0 1 Factories, workshops, handling areas 1.5 Retail B10, Retail banking 1.5 Gas stations, auto repair shops° 1.5 Locker and /or shower facilities 0.8 Institutions 1.5 Warehouses '1, storage areas 0.5 Libraries° 1.5 Aircraft storage hangars 0.4 Nursing homes 1.5 Parking garages See Sewn 1502 Wholesale stores (pallet rack shelving) 1.5 Mall concourses 1.4 Plans Submitted for Common Areas Only' Schools buildings, school classrooms, day care centers 1.35 Common area. corridors, lobbies (except mall concourse) 0.8 Laundries 1.3 Toilet facilities and washrooms 0.8 Office buildings, office /administrative areas in facilities of other use types (including but not limited to schools, hospitals, institutions, museums, banks, churches)5•111 _ 1.2 Footnotes for Table 15 -1 1. In cases in which a use is not mentioned specifically, the Unit Power Allowance shall be determined by the building official. This determination shall be based upon the most comparable use specified in the table. See Section 1512 for exempt areas. 2. The watts per square foot maybe increased, by two percent per foot of ceiling height above twenty feet, unless specifically directed otherwise by subsequent footnotes. 3. Watts per square foot of room may be increased by two percent per foot of ceiling height above twelve feet. 4. For all other spaces, such as seating and common areas, use the Unit Light Power: allowance for assembly. 5. Watts per square foot of room may be increased by two percent per foot of ceiling height above nine feet. 6. Includes pump area under canopy. 7. In cases in which a lighting plan is submitted for only a portion of a floor. a Unit Lighting Power Allowance of 1.35 maybe used for usable office floor arca and 0.80 watts per square foot shall be used for the common areas, which may include elevator space, lobby area and rest rooms. Common areas, as herein defined do not include mall concourses. 8. For the tire engine room, the Unit Lighting Power Allowance is 1.0 watts per square foot. 9. For indoor sport tournament courts with adjacent spectator seating, the Unit Lighting Power Allowance for the court area is 2.6 watts per square foot. 10. For both Retail A and Retail B, light for free - standing display, building showcase illumination and display window illumination installed within two feet of the window are exempt. Retail A allows a Unit Lighting Power Allowance of 1.0 watts per square foot. Ceiling mounted adjustable tungsten halogen and HID merchandise display illuminaries are exempt. Retail B allows a Unit Lighting Power Allowance of 1.5 watts per square foot, including all ceiling mounted merchandise display luminaries. 11. Provided that a floor plan, indicating rack location and height, is submitted, the square footage for a warehouse may be defined, for computing the interior Unit Lighting Power Allowance, as the floor area not covered by racks plus the vertical face area (access side only) of the racks. The height allowance defined in footnote 2 applies only to the floor areaonot covered by racks. 11/25/1996 11:09 �.FMERALD GLASS EMERALD GLASS CYO., INC 15534 NE 96% 1 R.d,..n4 WA 91852 PHON?.? (206) 881 -0997 FAX: (206)118I -1906 _206 881 1906 P.01 Fax Cover Sheet Number ofpages including cover shed: 2 DATE: NOVEMBER 25,1996 7V: GARY S / 70M COMPANY: U.S. COURTS /M.M..1. SERVICES FROM: ROBB PROJECT: U.S COURTS MESSAGE: (ARE TI11NIS1f REGARDS 119) THR 71111'F.R2 UldISS THAT WAS INSTALLED.-JJJE lFOLLQIVINCIPAPERWQPA ISA $1GN D .SNIPPINGDd 4 J:l FROM OUR GLASS ,Sl1PJ'JJF'R. IF YOU NEED ANYTIHN2?4QRLr. PI.F.ASt: CALL AND LEIJ,L HELP JIOWEVISJl CAN, RECEIVED CITY OF TUKWILA NOV 251996 PERMIT CENTER CUSTOMER • ACCOUNT ' . • ' NO. , •, i • • 2486 WHOLESALERS OF FLAT GLASS MID:INSIA.ATING GLASS UNlFS ' . • . • 17830 West VMey Highway, Seale, WA 96188 • • - PHONE (206) 6562626 :'FAX: (206) 6562601 11- 8045522227 • ,r. EMERALD. GLASS • .•15334 NE : 96TH PLACE . . REDMIOPID ' WA ...98052 SHIP VIA: • • -SALES ORDER ORDER NO. • - • TOTAL WT. • • TOTAL SO FT. • EMERALD GLASS .• • • 15334 ..NE • 96:TH • PLACE REDMOND, WI... 9015E ' • . JOB a U. 6. 'COURTS. - PAGE 291951 MD-F ', • 289.95 • 109.98 • 9661 /SZ/IT . • 1 • • • Hartung Gina Industries ms barn no mu or illy far . a IMddany consequontla us of Ma p dew P oor r damages roduuctt not tota� by the buyrrr. . • . ORDER TOTAL IlocaWi Auonw..o.aYIIwH..1Y111MINI MIww/11. CUSTOMER COPY 9061 188 9 City of Tukwila Fire Department Fire Department Review Control #D96 -0013 (512) John W. Rants, Mayor Thomas P. Keefe, Fire Chief September 26, 1996 Re: U.S. Courts - 14240 Interurban Avenue South Dear Sir: The attached set of building plans have been reviewed by The Fire Prevention Bureau and are acceptable with the following concerns: 1. Maintain fire extinguisher coverage throughout. Clear access to fire extinguishers is required at all times. They may not be hidden or obstructed. (NFPA 10, 1 -6.5) 2. Exit doors shall be openable from the inside without the use of a key or any special knowledge or effort. Exit doors shall not be locked, chained, bolted, barred, latched or otherwise rendered unusable. All locking devices shall be of an approved type. (UFC 1207.3) Dead bolts are not allowed on auxiliary exit doors unless the dead bolt is automatically retracted when the door handle is engaged from inside the tenant space. Exit hardware and marking shall meet the requirements of the Uniform Fire Code. (UFC 1207.1 - 1212.8) Aisles leading to required exits shall be provided from all portions of buildings. Aisles located within an accessible route of travel shall also comply with the Building Code requirements for accessibility. (UFC 1204.1) Combustible material shall not be stored in exits or exit enclosures. (UFC 1103.3.2.3) Headquarters Station: 444 Andover Park East • Tukwila, Washington 98188 • Phone (206) 575-4404 • Fax (206) 575-4439 City of Tukwila Fire Department Page number 2 John W. Rang Mayor Thomas P. Keefe, Fire Chief 3. All new sprinkler systems and all modifications to existing sprinkler systems shall have fire department review and approval of drawings prior to installation or modification. New sprinkler systems and all modifications to sprinkler systems involving more than 50 heads shall have the written approval of the W.S.R.B., Factory Mutual, Industrial Risk Insurers, Kemper or any other representative designated and /or recognized by The City of Tukwila, prior to submittal to the Tukwila Fire Prevention Bureau. No sprinkler work shall commence without approved drawings. (City Ordinance #1742) Sprinkler protection shall be extended to all areas where required, including all enclosed areas, below obstructions and under overhangs greater than four feet wide. (NFPA 13 -4- 4.1.3.2.1) Contact The Tukwila Fire Prevention Bureau to witness all required inspections and tests. (UFC 10.503) (City Ordinance #1742) 4. Maintain square foot coverage of detectors per manufacturer's specifications in all areas including: closets, elevator shafts, top of stairwells, etc. (NFPA 72, 5- 1.3.4) All new fire alarm systems or modifications to existing systems shall have the written approval of The Tukwila Fire Prevention Bureau. No work shall commence until a fire department permit has been obtained. (City Ordinance #1742) (UFC 1001.3) Call the Tukwila Fire Department at 575 -4407 for approval of any system shut down. Have job site address, name and the Tukwila Fire Department Job Number available to confirm shut down approval. (City Ordinance #1742) 5. All electrical work and equipment shall conform strictly to the standards of The National Electrical Code. (NFPA 70) Headquarters Station: 444 Andover Park East • Tukwila, Washington 98188 • Phone; (206) 5754404 • Fax (206) 5754439 City of Tukwila Fire Department Page number 3 John W. Rants, Mayor Thomas P. Keefe, Fire Chief 6. Required fire resistive construction, including occupancy separations, area separation walls, exterior walls due to location on property, fire resistive requirements based on type of construction, draft stop partitions and roof coverings shall be maintained as specified in the Building Code and Fire Code and shall be properly repaired, restored or replaced when damaged, altered, breached, penetrated, removed or improperly installed. (UFC 701) This review limited to speculative tenant space only special fire permits may be necessary depending on detailed description of intended use. Any overlooked hazardous condition and /or violation of the adopted Fire or Building Codes does not imply approval of such condition or violation. Yours truly, The Tukwila Fire Prevention Bureau cc: TFD file ncd Headquarters Station: 444 Andover Park East • Tukwila, Washington 98188 • Phone (206) 575.4404 • Fax (206) 57$.4439 ::t.•.• ::, 1,7 Ybr':::i'i3liii2i.1 i'7i+3F '?f7;;'J, ' i`.?. Y� :�&Y3Y'Glt`F.Y1AS3tlMGS,i{rvw1:Y C City of Tukwila i C�V9f�'.YY'.9K[tlfC.is.(SS ?IYLR� i%S S4 1Wflt Sf.'� zCAM1YlVx' G?+ GH+ tMhIrMV+ wtl. nS+ Hxof.M.YO1uM�r.M.x.w+w� +ww.rvrc, FILE COPY John W. Rants, Mayor Department of Community Development Steve Lancaster, Director September 17, 1996 Mr. Frank Heffernan Ferrari Design Group 12277 - 134th Court Northeast Redmond, Washington 98052 Dear Mr. Heffernan: SUBJECT: Development Permit Application Number D96 -0013 U.S. Courts 14240 Interurban Av S This letter is to inform you that your permit application received at the City of Tukwila Permit Center on September 13, 1996, was reviewed at the September 17, 1996, plan review meeting. Your application was determined to be complete. Your permit has begun the plan review process, you will be notified of any corrections or when your plan is approved. If you have any concerns or questions please contact me at the City of Tukwila Permit Center at (206) 431 -3672. Sincerely, -7-$4.1c,(1) `7°.titi‘sor) Kelcie J. Peterson Permit Coordinator File: D96 -0013 6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • (206) 431-3670 • Fax (206) 4313665 46§P30.4E6807H! ;sr :4Aptipmpt.44A J79E1052 ;.. • '3 :OF LABOR'ANYINthJSIBIES , p_D. WALL MOUNTED I INCANDESCENT LIGHT EIKNRE MIRROR GRAB BAR a —} F (Enlarged Restroom Plan ( Restroom Elevation SCALE: 1/4" = 1' -D" Ddb -�13 a SCALE: NV = 1' -D' CKS JUSTAB6E SHELVES - y L � REF. I OWork Rm. Cabinet Elevation O Galley Cabinet Elevation SCALE 1/2' =R -D' SCALE 52' = 1-0' I S - 31/2" METAL STUD FOR LATERAL SUPPORT ATTATCH W/(2) H6 SCREWS TAB. EXTEND STUD TO ROOF STRUCT 3/4" PLYWOOD 61 WATER HEATER LOCATION S" X 20 GA MTL JOIST @) 15" O.C. ATTACH W/(3) A6 SCREWS 5/S" WATER RESISTANT GW B ON RESTROOM SIDE ONLY. ATTATCH W/ TYPE "S" SCREWS @ S" OC PANEL EDGES 812" O.C. PANEL FIELD 31/2 X25 GA METAL STUD 3112" SOUND BATT INSULATION ORestroom Wall NO SCALE / I COMMUNICATION GHILL ®- PASS THROUG 1 OWork Room Cabinet Elevation (Reception Counter Elevation SCALE 1/2' = 1' -O' SCALE 1/2' = Y -D' SECURITY GLASS Waging Area Counter Elevation a' SCALE 1/2" = P -D' CITY OF TURNIIA APPROVED SEP 2 7 1996 AS NDIED BUILDING 0:01;105 pt W° SEP 13 1996 P 2 c C 7 3 3 0 -3 C� H E J H Z O J J <B J � W CC W CC FERRARI DESIGN GROUP. ARCHITECTS, PS 'TELEPHONE 206. 821. 3383 A 12277 134TH COURT NE SUITE 203, REDMOND, WA 98052 -2433 SHEET A2 Dr 2 De Wo94040.11 -1\ / \ BACKSPLASH I / / - -__ \\ -- F AD.IHSTA6!E -_ SHELVES - - -\ / II ___ - -\� SCALE 52' = 1-0' I S - 31/2" METAL STUD FOR LATERAL SUPPORT ATTATCH W/(2) H6 SCREWS TAB. EXTEND STUD TO ROOF STRUCT 3/4" PLYWOOD 61 WATER HEATER LOCATION S" X 20 GA MTL JOIST @) 15" O.C. ATTACH W/(3) A6 SCREWS 5/S" WATER RESISTANT GW B ON RESTROOM SIDE ONLY. ATTATCH W/ TYPE "S" SCREWS @ S" OC PANEL EDGES 812" O.C. PANEL FIELD 31/2 X25 GA METAL STUD 3112" SOUND BATT INSULATION ORestroom Wall NO SCALE / I COMMUNICATION GHILL ®- PASS THROUG 1 OWork Room Cabinet Elevation (Reception Counter Elevation SCALE 1/2' = 1' -O' SCALE 1/2' = Y -D' SECURITY GLASS Waging Area Counter Elevation a' SCALE 1/2" = P -D' CITY OF TURNIIA APPROVED SEP 2 7 1996 AS NDIED BUILDING 0:01;105 pt W° SEP 13 1996 P 2 c C 7 3 3 0 -3 C� H E J H Z O J J <B J � W CC W CC FERRARI DESIGN GROUP. ARCHITECTS, PS 'TELEPHONE 206. 821. 3383 A 12277 134TH COURT NE SUITE 203, REDMOND, WA 98052 -2433 SHEET A2 Dr 2 De Wo94040.11