HomeMy WebLinkAboutPermit B93-0108 - BARGHAUSEN RESIDENCE - MASTER BEDROOM AND HALLWAYBARGHAUSEN REMODEL
B93-0108
City of 7iukwi16. ,
(206) 431-3670
Community Development / Public Works • 6300 Southcenter Boulevard, Suite 100 • Tukwila, Washington 98188
BUILDING PERMIT
Permit No: B93 -0108
Type: B -BUILD
Category: ASFR
Address: 16440 53 PL S
Location:
Parcel #: 779640 -0140
Zoning:
Type Const: V -N
Gas /Elec: ELEC
Wetlands:
Water: TUKWILA
Contractor License No.: SILVEHI104C3
TENANT
OWNER
CONTRACTOR
CONTACT
Status: ISSUED
Issued: 05/20/1993
Expires: 11/16/1993
Type of Occupancy: DWELLING
Slopes: Y
Sewer: TUKWILA
BARGHAUSEN REMODEL
16440 53 PL S, TUKWILA, WA 98168
BARGHAUSEN THOMAS A
16440 53 PL S, TUKWILA, WA 98168
SILVERSTAR HOMES
18215 72 AVENUE SOUTH, KENT, WA 98032
DANIEL B. GOALWIN
18215 72 AVENUE SOUTH, KENT, WA 98032
•
Phone: 206 251 -6222
Phone: 206 251 -9488
Phone: 206 251 -6222
***** *k ** ** **** ****• *** *** **** * *** * ***** * * * **** *•k**** ******* **** *fir *** ***•kk**
Permit Description:
ADDITION TO EXISTING MASTER BEDROOM, ADD HALLWAY
Units: 001
Buildings: 001
Fire Protection: DETECTORS
UBC Edition: 1991
SETBACKS
Front: .0 Back: .0
Left: .0 Right: .0
Valuation: 16,800.96
Total Permit Fee: 301.50
* * *• ***** k******************************** * * * * * * * * * * *•k * * * * * ** * * * * ** *** **
41,
rm t Center Authori d Signature �> y
Date
I hereby certify that I have read and examined this permit and know the
same to be true and correct. All provisions of law and ordinances
governing this work will be complied with, whether specified herein or not.
The granting of this permit does not presume to give authority to violate
or cancel the provisions of any other state or local laws regulating
construction or the performance of work. I am authorized to sign for and
obtain this ping permi
- -� —
Date: -- ,� 03
Tit 1 e :. /451 f,KY
This permit shall become null and void if the work is not commenced within
180 days from the date of issuance, or if the work is suspended or
abandoned for a period of 180 days from the last inspection.
Signature:
Print Name: fK
MP" sex: F' fiCW,isbSY!tTir7:i!rwaG:"':w,+A n tVA,A`, 1wltM1r�ffC'',r'�,s`�,z,"!,1' F9:v,���k"f!:!1»; 1°• S�';M,7:a'ax.;�„��4'�atr�tu�wt�, ,.. �;1,'�!,4+at:txtn'Lr:,.�1,
z
w
6
-I
U0
U0
CD uJ
J=
w0
gQ
N
=d
w
z�
zI-
L1.1
w
n
O -
O F-
WW
H 17-
LL'O
wz
U=
O~
z
CITY OF TUKWILA
Address: 16440 53 PL S
Permit No: B93 -0108
Tenant: BARGHAUSEN REMODEL Status: ISSUED
Type: B -BUILD Applied: 03/23/1993
Parcel #: 779640 -0140 Issued: 05/20/1993
*• k** k*k**************• kQ• k*** k•kk****-k*****k *kkkkk*kkk*•kl kkkkk ******k•kk**kkk*
Permit Conditions:
1. No changes will be made, to:the plans unless approved by the
Tukwila Building Division,
2. Electrical permit shall be obtained. through the Washington
State Division of Labor a'nd`Industries and all electrical
work will be.inspected by that agency (248- 6657). •
3. All permits, .inspection_records,.and approved plans shall be
maintained available at the job site prior to the start of
any construction. These documents are to be maintained
available until final inspection approval is granted.
4. Any exposed insulations backing material shall have a Flame
Spread Rating of 25 or less, and material shall bear identi-
fication showing the fire performance rating thereof.
5. All new windows to be installed shall have a tested U -value
of 0..58 (or less) and shall bear the manufacturers label.
6. A11 c•onstruction to be done in.conformance with approved
plans, and requirements of the Uniform Building Code (1991
Edition) as amended by the Washington State Building Cod,
Uni:fo`rm Mechanical Code (1.991 Edit;ion), and Washington State
Energy Code (1991 Second Edition).
7. Validity . of Permit:. The issuance of a permit or approval . of
plans, specifications and computations shall not be con -
strued to be a permit for, or an. approval of,•any violation
of any of the provisions of this code or of any other
ordinance of the jurisdiction. No permit' presuming to :,give
authori,tyor violate or cancel the provisions of this code
shall bee valid.
it`i zf.A7 '�?�rett !b7tw" kYY..al a samideeogsfiXdYRIG
z
z
rew
6U
00
w
J F=-
rnw
wo
�Q
=d
� w
z=
H
zo
w
w
U �
O D-
o e -
-
w W
LL- 0
W
• =
O 1-
z
BUILDIN PERMIT
APPLICATION
CITY OF TUKWILA
Department of Community Development - Building Division
6300 Southcenter Boulevard, Tukwila WA 98188
(206) 431 -3670
PLAN CHECK
NUMBER
- c)/0
iiir.'or.:: '•Yh 'r: : iY .•5:1ff;.::'• /:i/i %����• ',•.'..: ` 7.::%1.,:.`::r %f:
DESCRIPTION
AMOUNT
RCPT #
DATE
BUILDING PERMIT FEE
PLAN CHECK FEE
/ W. CO
SO
BUILDING USE (office, warehouse, etc.) �
- -c
BUILDING SURCHARGE
5�i
SQUARE FOOTAGE - Building: . ia(),{ , Tenant Space:
Area of Construction: 0, ./S;,L-
OR HAZARDOUS MATERIALS IN THE BUILDING?
WILL THERE BE STORAGE OR USE OF FLAMM • BLE, COMBUSTIBLE
No ❑ Yes IF YES, EXPLAIN:
OTHER:
TOTAL -
)1,5 )
SITE ADDRESS SUITE #
/ &��o 63 /-1 /-- ep e,e��t
VALUE OF CONSTRUCTION - $
(, ',,, c & di,„1 O
PROJECT NAME/TENANT
/e: -/
94-e', AZki
ASSESS• - • CCOUNT # , :•• i : 'trirrr''/7' "V
779m49-710
(commercial) ❑ Demolition (building)
❑ Other.
TYPE F ❑ New Building N. Addition ❑ Tenant Improvement
WORK: ❑ Rack Storage ❑ Reroof ❑ Remodel (residential)
DESCRIBE WORK TO BE DONE:
G ea( /0 Xis / /'44 4,e�vcvOit �r/ vet v • ✓�2 c� iu vZ
BUILDING USE (office, warehouse, etc.) �
NATURE OF BUSINESS: A_
requirements may need to be met. Please explain:
WILL THERE BE A CHANGE IN UST-?-21 No ❑ Yes If Yes, new building
SQUARE FOOTAGE - Building: . ia(),{ , Tenant Space:
Area of Construction: 0, ./S;,L-
OR HAZARDOUS MATERIALS IN THE BUILDING?
WILL THERE BE STORAGE OR USE OF FLAMM • BLE, COMBUSTIBLE
No ❑ Yes IF YES, EXPLAIN:
PROPERTY OWNER r iewea A 2,�� /ee,e5e fr PHONE ZS-� (.z7 Z
6 ADDRESS / q3rcl i r, ��! /(fit
IZIP
PHONE � �
CONTRACTOR cJl1(.,C/15h°y! ���/ 2., —L, - hke..�r r
`,
ADDRESS /g- 7ZNa Ae .5;ezi 4 / iaf
ZIF30 5 2
WA. ST. CONTRACTOR'S LICENSE # v/L V6// le4G
EXP. DATE ,c Z�� /9//
ARCHITECT i\/14
PHONE /
ADDRESS
ZIP
HEREBY : CERTIFY: THAT 1; HAVE = AD: AND'EXAMIN D: •THIS;;APPLICATION;AND. KNOW: THE SAME TO
BE <TRUE'.AND: CORRECT; 'AND' .:AM • UTHORIZED' T AAPPLY FOR THIS;:P.ERMIT,
BUILDING OWNER
OR
AUTHORIZED
AGENT
SIGNATUR , �A' c_.- --L_____\"__
DATE 5/2-3 jI 3
PHONE /
2� / 6Z z Z
PRINT NAME /
Jaw / /�. e'= .6CC2�l�L
ADDRESS/ ,is 2" �e .
i
CITY/ZIP Z. Aa 3Z
CONTACT PERSON c / .4e / / / e /Ar
PHONE0.s ./_vZZ Z
APPLICATION SUBMITTAL In order to ensure that your application is accepted for plan review, please make sure to fill out the
application completely and follow the plan submittal checklist on the reverse side of this form. Handouts are available at
the Building counter which provide more detailed information on application and plan submittal requirements.
Application and plans must be complete in order to be accepted for plan review.
VALUATION OF CONSTRUCTION Valuation for new construction and additions are calculated by the Department of
Community Development prior to application submittal. Contact the Permit Coordinator at 431 -3670 prior to submitting
application. In all cases, a valuation amount should be entered by the applicant. This figure will be reviewed and is
subject to possible revision by the Building Division to comply with current fee schedules.
BUILDING OWNER / AUTHORIZED AGENT If the applicant is other than the owner, registered architect/engineer, or contractor
licensed by the State of Washington, a notarized letter from the property owner authorizing the agent to submit this
permit application and obtain the permit will be required as part of this submittal.
EXPIRATION OF PLAN REVIEW Applications for which no permit is issued within 180 days following the date of application shall
expire by limitations. The building official may extend the time for acti;ab _,i 'ad not exceeding 180
days upon written request by the applicant as defined in Section 304( )rof ode (current edition).
No application shall be extended more than once.
If you have any questions about our process or plan submittal requirements, please
contact the Department of Community Development Building Division at 431 -3670.
DATE APPLICATION ACCEPTED
yR 2 3 1993
DATE APPLICATION EXPIRES
- 9:j
03/ 16/01
z
�Z
CL w
JU
000
W=
F-
LL
w0
u_ Q
1. a
in
z=
w1-
• w
U�
O —
CI—
LL! uj
• ci
LI Z
w
U=
O ▪ 1-
z
L
COMMERCIAL
SUBMITTAL CHECKLIST
NEW. COMMERCIAL BUILDINGS /ADDITIONS
Completed building permit application (one for each structure)
'Assessor Account Number
Two sets (2) of the following
:Specifications.
Structural: calculations stamped by a Washington State licensed,
.,engineer.
Soils report stamped by a: Washington State licensed engineer
:Topographical survey.
El
.Energy calculations stamped by a Washington State licensed .
engineer or.architect
[Legal description
Working drawings, stamped by a Washir.gton State licensed
architect,: which. include:
•:Site elan
• ..Architectural drawings
Structural drawings
Mechanical drawings
• Elevations .: •
.7 Civil drawings
Landscape plan
Completed utility permit application one for entire project)
Six (6) sets of civil drawings
NOTE .See Utility permit application and checklist for specific utility
submittal requirements
}
RACK STORAGE
Completed building permit application
Assessor Account Number
wo (2) sets of plans which include
Building•floor plan showing
Entire space where racks will be located.
• Exit 'doors
• Dimensions: of all aisles
:Tenant space floor plan showing rack storage layout, aisles and
exits •• . •
NOTE Include dimensions of racks (height :width and length).; aisles:.
and exit ways on plan..
•
:Structural calculations stamped by a Washington State license
engineer (rack storage 8` and over)
RESIDENTIAL
COMMERCIAL TENANT IMPROVEMENTS
Completed building permit application (one for each structure or
tenant)
Assessor Account Number
Two (2) sets of construction plans, which include:
Site plan
• Location of tenant space
• Existing and proposed parking
• Landscape plan (if applicable, i.e., change of use).::
Overall building plan ..
• Tenant location
• Use of adjacent (common wall) tenant
•.Overall dimensions of building or square footage
Floor plan of proposed tenant space.
• Tenant space plan with use of each room labelled..
• Exit doors, egress patterns: •
• New walls, existing wall, and walls to be demolished:
Construction: details
• Cross sections showing wall construction and method of
:.attachment for floor and ceiling
Structural calculations stamped by. a Washington State licensed
engineer may be required if structural work is to be:done •(2 sets)
NOTE :: /1 any utility work is to be done; submit separate utility permit
:application and. plans
REROOF. •
Completed building permit application (one! for each structure
Assessor Account'Number
Narrative describing` existing roof, material being removed, an'
material being installed
NOTE: .A certification letter is required prior to final inspection and sign-
off of the permit
it
ANTENNA/SATELLITE'DISHES
Completed building permit application.
Assessor Account Number :•
Two (2) sets'of.plans which include
Site Plan - (showing building and location of antenna/satellite •
Detalis.antenna/satellite dish and method:of attachment:
Structural calculations stamped by a <Washington State license
engineer may be required
EW .SINGLE - FAMILY.: DWELLINGS /ADDITIONS:'
Completed building permit application one
for.each'structure
RESIDENTIAL: REMODELS
Legal description;;
Assessor Account Number:
wo sets (2) of. working; drawings which.include ::
Site plan a>~. ion plan show.closesthydranrbcation:
Foundation plan • tndude access. to building; showing
• Floor . plan width and length of access:):
• Roof plan
•• •Buildingelevations(all views
• Building cross- section
tnictural; framing plans
Washington`StateEnergy Code data
onipleted utility permit applicati'
Six (6) sets of site plans showing titilitiec`.
NOTE: Building site plan and utility site plan may be combined.: See
utility. permit application and checklist for specific submittal requirements.
Additional topographical and soils information maybe required if unique
site; conditions
Completed building .permit application:
Assessor :Account Number:
one for each
structure
Two (2) sets`of working drawings; whichi include:
• Site plan
• 'Foundation. plan
Floor plan
Roof plan
Building elevations (all views
Building cross - section
Structural framing plans
NOTE if any utility work is to be done provide utility permit application:.
and plans must be submitted.
: REROOFS
Completed building permit application
Assessor. Account Number
Narrative, describing existing roof, material being removed, and,
material being installed.. :. `' •
NOTE: A certification letter is required prior to final inspection and •sign: •`:
off of the permit,.
41111111
CITY OF TUKWILA _ g
Department of Corr;., 'unity Development — Permit Center
6300 Southcenter Boulevard - #100, Tukwila, WA 98188
(206) 431 -3670
Building Permit Application
PLAN CHECK
NUMBER
1393-
PR JECT NAME ( f
Ac �PrU.SE 0c E. L
SITE ADDRESS
f (p #-O I) C5
INSTRUCTIONS TO STAFF
• Contacts with applicants or requests for information should be summarized in writing by staff so
that the status of the project may be ascertained at any time.
• Plan corrections shall be completed and approved prior to sending to the next department.
• Any conditions or requirements for the permit shall be noted in the Sierra system or summarized
concisely in the form of a formal letter or memo, which will be attached to the permit.
• Please fill out your section of the tracking chart completely. Where information requested is not
applicable, so note by using "N /A ", date and initial.
DEPARTMENTAL REVIEW
"X" in box indicates which departments need to review the project.
DEPARTMENT ' DATE IN
DATE
APPROVED REQUIREMENTS / COMMENTS
BUILDING -
initial review
' Z3�3
730/1:13K.
(ROUTED)
CONSULTANT: Date Sent - Date Approved -
BY:
(init.)
O FIRE
BY:
(init.)
FIRE PROTECTION: [ j Sprinklers J Detectors LJ N/A
FIRE DEPT. LETTER DATED: INSPECTOR:
INIT:
LANNING
3f 113 (ZONING:
E1
AR/LAND USE CONDITIONS? 'Yes No
REFERENC FILE NOS.:
/ j
INIT:
MINIMUM SETBACKS: N- S- E- W-
OPUBLIC �
WORKS /
,,L.yt /p„.
UTILITY PERMITS REQUIRED? ( ) Yes U No
PUBLIC WORKS LETTER DATED:
, !
INIT:
I
O OTHER
INIT:
BUILDING -
final review
of +WW • 02
lib o
TYPE OF CONSTRUCTION:
04 04
CERT. OF OCCUPANCY?
Oyes XNo
UBC EDITION (year):
199 1
IINI .. � dial
5 BUILDING
• FFICIAL
;.:
•
INIT: / ..
REVIEW COMPLETED
AMOUNT
OWING:�k
11
l $'.Q
CONTACTED vim
1 , 1P7�1
t? Ci
BY:
(init.) _WD
DATE NOTIFIED
2nd NOTIFICATION
BY:
(init.)
3RD NOTIFICATION
BY:
(init.)
01/08/93
FFF
* * *:k ** k:k ***4 *:k * * * *k k *:k * * ** * * * * *4k *** hh** **k *:k *•k *•k•A ** k k *k *•A ** A* k*
CITY OF TUKWILA, WA TRANSMIT
***4*•k*kk•k***** *4** * *k:1 *4k•kk**•A *, k ***k****:k***k****4 **4•k**k**4*
TRANSMIT Number: 94000512 Amount: 180.00 05/0.1/9 / x.40
Permit No 893-0108 Type: 0 -BUILD BUILDING PERM
Parcel No: 779640-0140
Site Address: 16440 53 PL 5
Payment Method: CHECK Notation: BARGHAUSEN, TOM Init: DLM
** k•*** k• k** k* k************** **** *kA* ***** * *** * *•k * *•k *A*kk* * * *k * **
Paid
Account Code Description
000/322.100 BUILDING •- RES
Total (This Payment):
Total•Fees:
Total All Payments:
Balance:
•
;:haUi zAia'.i:�.e�oYS idrtirlt}ii"�'4�+"C
481.50
481.50
.00
180.00
180.00
GENERA 180.00
TOTAL 180.00
CHECK 180.00
CHANGE 0.00
1667A000 0908
'•idi" �3ff5� i5A.
'mssE .t•= ,
g�LkR;�Rr�!"v
XF
z
~ W
6
-JU
UO
NO
J
F-
N u.
WO
u-Q
co
= Ci
�w
z=
I— O
I-
w
U�
O -
o ff
U
L"O
w z
U=
O I•-
z
..r. c.r1m.4-•kv:K•r, rrr„rfi!a „arwr T^ fit•' ,. :, tie -'
***** *****•k** **** ********k* ** ****;l * *4***h*** ** ****** * ** * *4 *•k ** **
CITY OF 1'UKWILA, WA TRANSMIT
* ** * ** * * ** * ** *** * *: ************** * ** ** ** * * * * * ** *** * *** * * * ** *4 * **
TRANSMIT Number: 93000624 Amount: 184.50 05/20/93 12:16
Permit No: B93-0108 Type: B--BUILD BUILDING PERMIT
Site Address: 16440 53 PL S
Payment Method: CHECK Notation: T. BARGHAUSEN IntlEapi 0
*•*** ** * **•k* * ** * ***•k * ***** heir*** **** *** *** ** * ********* ** *fie *** ***fie*
Paid
180.00
4.5()
184.50
Account Code
000/322.100
000/386.904
Description
BUILDING - RES
STATE BUILDING SURCHARGE
Total (This Payment):
Total Fees:
Total All Payments:
Balance:
301.50
301.50
.00
GENERA 180.00
GENERA 4.50
TOTAL 184.50
CHECK 184.50
CHANGE 0.00
0880A000 15:00
z
I- Z
w
QQ �
—.1 C.)
00
(/)O
W
LUX
W 0
ga
co
I
�w
z
I-0
z 1-
W
• W
O • N
CI 1-
ww
1-
O
w z
0 I
z
***•**********•*• k********•*: k*********• ********k**** *****k**** **k *h:k*
CITY OF TUKWILA, WA TRANSMIT
*** ** ***** * ** **** * ** *** ** *** ******** * **h•****•. .fk******k*** **** **•*
TRANSMIT Number:. 93000364 Amount: 117,00 03/23/93,�,)�. 15
Permit No B93 -0108 Type: B -BUILD BUILDING PER fZ'i�Y/ `
Site Address: 16440 53 PL 5
Payment Method: CHECK Natation: DANIEL GOALWIN Init: SAO
** ** * * * * * * * **4 *** * * * * * * * * *** **** *fir ***•kit * * * *• *• * *•k *A •k* *** *•k *** * ** *•k
Account Code
000/345 . 830
Description
PLAN CHECK - RES
Total (This Payment):
Total Fees:
Total All Payments:
Balance:
301• . 50
117.00
184.50
Paid
117.00
117.00
;:t,k.,r,h..�,+:.
•
!:i�! ,`i=�9 •irr•k7iiu c�Yu�y ,i„1; 'r.i:ghlrrlcud ifi4{4hid'adtiv414f +:a avkiz'.ia:ii li 4d:a`l:i
GENERA 117.00
TOTAL 117.00
CHECK 117.00
CHANGE 0.00
9i.17A000 17.16
4
Z
W
ce
JU
00
co 0
J=
W • O
LLQ
=a
1.. W
z=
I-
Z I—
W
W
U�
O D.
O H
WW
z
1—
uO
z
U=
O
z
Oct 03, 1994
City of Tukwila John W. Rants, Mayor
Department of Community Development Rick Beeler, Director
DANIEL B. GOALWIN
18215 72 AVENUE SOUTH
KENT, WA
98032
RE: BARGHAUSEN REMODEL
Dear Permit Holder:
i
Our records indicate that on Nov 16, 1994, one hundred and eighty days will
have passed with no inspections having been called for under Tukwila
Building Permit Number B93 -0108. Unless you call for an inspection,
or obtain a written extension from the Tukwila Building Official prior to
that date, your above referenced permit will become null and void on
Nov 16, 1994.
If your project has been completed please call for final. If you are
actively working on it please notify our office.
If you have any questions or need further information.to obtain an
extension on your permit, please call the Tukwila Building Divison at
431 -3670.
Sincerely,
She( lie Bates /Sylvia dsby
Permit Technicians
Department of Community Development
6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • (206) 431 -3670 • Fax (206) 431-3665
'sk''SIS?i. .F`A- a a :44i1itOdszlw'lf'ita'k+a"
mSv,gfr,r,. WIT,,,
z
Z
00
CO
cn w
1
�LL
w0
H
0-
CI
f-
ww
�
u O
wz
=
F.
z
Ms. Denise Millard
City of Tukwila
6200 Southcenter Boulevard
Tukwila, WA 98188
CIVIL ENGINEERING, LAND PLANNING, SURVEYING, ENVIRONMENTAL SERVICES
May 2, 1994
RE: Building Permit Extension for Barghausen Remodel
Dear Ms. Millard:
Pursuant to your letter of April 15, 1994, I am pleased to enclose a check in the
amount of $180 to extend the above - referenced permit. I understand this will be the final
extension for this permit. If the work is not started, we will resubmit the application again
for a new review. Thank you.
Respectfully,
�JC
Thomas A. Barghausen, P.E.
President
TAB /ps
055
enc: As Noted
cc: Daniel B. Goalwin, Barghausen Consulting Engineers, Inc.
RECEIVED
MAY 0 51994
DEVE OPMENT
18215 72ND AVENUE SOUTH KENT, WA 98032 (206) 251 -6222 (206) 251 -8782 FAX
.,. 9.:Si6 ii: ;.ba1�;.'.•X i ij:N +diti s:i�.�irt+ :+z47'�%'i�F1r, . + ti, `� u,� ;�r Nt-
u�.�S{is15. ^�G,�i.4 `�llsst�1!LCRS'�e26114: ".'�:'�' 1�3. iw�'? fr`. ti��+`f' Si1: ��t.. yY .,' « °,�...�1�t5�t':d,"ir�?'��
z
~ w
cQQ�
JU
00
W
J =
• LL
W O
2
�a
=a
w
z�
I- O
z
w
W
O ▪ Y2 .
oI-
wW
• 0.
O
uiz
0 22
t=
O~
z
City of Tukwila John W Rants, Mayor
Department of Community Development Rick Beeler, Director
April 15, 1994
Mr. Thomas Barghauscn
Barghauscn Engineering
1821572AVS
Kent, , WA 98032
Dear Mr. Barghausen:
Our records indicate a request for extension was granted November 19, 1993. Your request for an
additional six month extension will be granted under the following conditions:
1. A fee of $180.00 is required for this extension.
2. This extension will expire November 16, 1994. No further extensions shall be granted.
3. If work is not commenced within 180 days or your project is abandoned you must
apply for new permit. Resubmittal of plans, application and fees will be required.
If you have any questions or concerns please contact me at 431 -3672.
Sincerely,
,&ZG'e /7.
Denise Millard
DLM/dlm
6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • (206) 431-3670 • Fax (206) 431-3665
z
re w
QQ=
J0
00
0
CO Ill
a=
w0
LQ
2d
H w
z=
F- 0
w~
• w
U 0
O N
O H
W W'
u-O
wz
0=
O ~
z
CITY OF TUKWILA Id: MISC120 Keyword: UACT User: 1672
Comments regarding an Activity
Permit No: B93 -0108 Tenant: BARGHAUSEN REMODEL
Status: ISSUED Address: 16440 53 PL S
04/15/94
BUILDING PERMIT
Line User Id Text
1 1671 REVISED ENERGY CALCS SUBMITTED 5 -14 -93 BY DANIEL GOALWIN.
2 1672 LETTER MAILED REQUESTING EXTENSION DATED 10- 19 -93. DUE
3 1672 TO FINANCIAL REASONS. ONLY ONE EXTENSION IS GRANTED NO OTHER
4 1672 EXTENSIONS WILL BE ALLOWED THIS PERMIT HAS BEEN MOVED BACK
5 1672 TO EXPIRE IN MAY ON THE 16TH 1994. SEE FILE FOR LETTER. DLM
Enter Option: A =Add, C= Change, D= Delete, I= Inspect
Up /Down= Select, PgUp /PgDn(F2) =Page, F3 =First 12, ESC =Exit
-to&
Ms. Denise Millard
Permit Coordinator
Department of Community Development
City of Tukwila
6200 Southcenter Boulevard
Tukwila, WA 98188
CIVIL ENGINEERING, LAND PLANNING, SURVEYING, ENVIRONMENTAL SERVICES
April 11, 1994
RE: Extension for Barghausen Remodel Permit No. B93 -0108
Dear Ms. Millard:
Pursuant to your letter of April 5, 1994, I would like to request another 6 -month
extension for the above - referenced building permit application. We need to wait until the
dry summer months to begin work on this project because of the potential for rain damage
while the remodel is ongoing.
Please let me know if a fee is required for this extension. Thank you for your
consideration.
Respectfully,
Thomas A. Barghausen, P.E.
President
TAB /ps
051
cc: Mr. Daniel B. Goalwin, Barghausen Consulting Engineers, Inc.
RECEIVED
APR 1 2 1994
COMVIIVIUNITY
DEVELOPMENT
18215 72ND AVENUE SOUTH KENT, WA 98032 (206) 251 -6222 (206) 251 -8782 FAX
QQ�
JU
00
co
UJ
J �.
w0
�w
zI
I- 0
zH
w uj
U�
aF-
w w.
H1-
U. 0
wz
0E-
z
Apr 05, 1994
City of Tuk v la John W. Rants, Mayor
Department. of Community Development Rick Beeler, Director
DANIEL B. GOALWIN
18215 72 AVENUE SOUTH
KENT, WA
98032
RE: BARGHAUSEN REMODEL
Dear Permit Holder:
Our records indicate that on May 16, 1994 one hundred and eighty days will
have passed with no inspections having been called for under Tukwila
Building Permit Number B93 -0108. Unless you call for an inspection,
or obtain a written extension from the Tukwila Building Official prior to
that date, your above referenced permit will become null and void on
May 16, 1994.
If your project has been completed please call for final. If you are
actively working on it please notify our office.
If you have any questions or need further information to obtain an
extension on your permit please call the Tukwila Building Divison at
431 -3670.
Sincerely,
Denise Millard
Permit Coordinator
Department of Community Development
6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • (206) 4313670 • Fax (206) 431-3665
Ms. Denise Millard, Permit Coordinator
City of Tukwila
Department of Community Development
6300 Southcenter Boulevard, Suite 100
Tukwila, WA 98188
CIVIL ENGINEERING, LAND PLANNING, SURVEYING, ENVIRONMENTAL SERVICES
October 19, 1993
RE: Building Permit No. B93 -0108 - Barghausen Residence Remodel
16440 53rd Place South, Tukwila, Washington
Dear Ms. Millard:
On behalf of Mr. Tom Barghausen, the owner of the residence, I am formally requesting an extension
on Building Permit No. B93 -0108. The owner still intends to perform the remodel once economic factors
allow. Would you please extend the permit the maximum of 180 days, which I believe is May 16, 1994.F)'
tip). }t_ 101
If you have any questions, comments or need any additional information, please feel free to contact me
at (206) 251 -6222.
DBG /sm
C.385
Daniel B. Goalwin
Architect /Project Manager
RECEIVED
OCT 2 1 1993
COMMUNITY
DEVELOPMENT
18215 72ND AVENUE SOUTH KENT, WA 98032 (206) 251 -6222 (206) 251 -8782 FAX
z
w
000
N
1• _
cn u.
w0
Id
_
z�.
t— 0.
Z F-
w
w
U O
O C
O 1-
w• w
I-
LL. z
ui
O
z
Oct 07, 1993
City of Tukwila
John W. Rants, Mayor
Department of Community Development Rick Beeler, Director
DANIEL B. GOALWIN
18215 72 AVENUE SOUTH
KENT, WA
98032
Dear Permit Holder:
Our records indicate that on Nov 16, 1993 one hundred and eighty days will
have passed with no inspections having been called for under Tukwila
Building Permit Number B93 -0108. Unless you call for an inspection,
or obtain a written extension from the Tukwila Building Official prior to
that date, your above referenced permit will become null and void on
Nov 16, 1993.
If your project has been completed please call for final. If you are
actively working on it please notify our office.
If you have any questions or need further information to obtain an
extension on your permit please call the Tukwila Building Divison at
431 -3670.
Sincerely,
Denise Millard
Permit Coordinator
Department of Community Development
6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • (206) 431-3670 • Fax (206) 431 -3665
C;`..'f:!'.�sr?`ti'' Yip:' 7ji>.. '.� +w °r::r:i1r,;;t.�u?t.SYt'!. :�;� /.',r�a,•,Ir,to.,ta�
z
• w
ce
.J U
O 0
u) o
• w
wJ =
w • 0
u.
cr)�
Ec
1- w
z =
z0
U.1
• w
O • N
c u--
wW
- 0
wz
U=
O
z
CITY OF TUKWILA
6300 SOUTHCENTER BOULEVARD
TUKWILA, WA 98188
* `~ REVUE ON SUS a TTAL * *
DATE 5/ ///9 3
RECEIVED
CITY OF TUKWILA
MAY 1 4 1993
PERMIT CENTER
PROJECT NAME 25749 47.1,, /� )+J�GPI`,e" 4 8 %3 ' 42,40g
ADDRESS
CONTACT PERSON
ARCHITECT OR ENGINEER
PHONE Z 5I -6.7 z
PLAN CHECK/PERMIT NUMBER 'eIevo
TYPE OF REVISION: ) If € -Gc /lush ) f'ek u ~' '���'S'L®
y
1.e & -/
17" it ,.� V,t VA/ /9 3—
SHEET NUMBER(S) G' S
"Cloud" or highlight all a rea ons and date revisions.
SUBMIT IIbD TO:
MMONS
Wag)
'Do►Nleyr Fiau.GI compt9
NAVE MGR AREA < 760 'SF
3{-},d,.L E ,ZS,W DOED • Pco 1 DEt AT
I. (MPRa0EM6tt'[S (312,2, MpDE ID 741. -a F -ASTI Nc
Cc-co 9,400(A CompoN5A(TE -1-Wo)
4cbEFIGIA ES IN 140.0 AooMON
z. V0f4 CuAFORmnmic AvDtrioN 4
uw/pyrDEp exis-t-cccct cm) Rawki 514aLc.
cizt4OE AN �E-teloci ZzXner a2 -0-E0.T z.oss
(oAt cg is G 744-E. cJ N I M pg-0cJED i= aclSTit�
12-LicLott\ti . WITA-It-E.-74DDiTioN V1_24,&oftrz3
Comeil tit)/ 4-4416 Ce5Pg,
.H4i/u5D ctwiL 1
c&awis
83 %C�•e' z+N. rJ.Co. wio CAUL
THERMAL PERFORMANCE CRITERIA
AREA
TABLE 4.2U
TOTAL UoxAo
FLOOR
Exist.
2025
.055
111.37
Prev. Add.
452
.055
24.86
New Add.
258
.055
14.19
CEILING /ROOF
Exist.
2025
.035
70.87
Prev. Add.
452
.035
15.82
New Add.
258
.035
9.03
WALL .
Exist.
2916
.203
591.95
Prev. Add.
700
.203
142.10
New Add.
692.5
.203
140.58
1084.77 SF
i" �AS; t• kt.:' fv" iCt�2��a� +ut'ah7;til��.da�1'.tit X ' r "ti:et„
MAR 2 3 1994
M.136 [DBG /cbjl
Z
w
J0
0 0
NO
J=
�w
w0
maw' a
D. 2d
w
Z�
I— 0
Zi--
w
• w
O co
0-
0—
W W
HI-
-0
W
.. Z
U=
0
Z
-2-
.;h1..- `ttiNWOxr. * AlgiNPO 4401i'■,;:,f on- V:t40a,'
?4AR 2 3 193
M.I36 [DBG /cbj]
DESIGN CRITERIA
Assume Existing Area from Original Plan
lAREA
I TABLE 4.2U
f TOTAL Uo x Ao
[ (Exist) 813.55 SF
FLOOR
Prev. Add.
452
.05
22.6
New Add.
258
.05
12.9
CEILING /ROOF
Prev. Add.
452
.033
14.92
New Add.
258
.033
8.51
WINDOWS
Prev. Add.
102.5
.58
59.45
New Add.
116.0
.58
67.28
GLASS DOOR
Prev. Add.
18
.58
10.44
New Add.
-0-
-0-
-0-
WALLS
Prev. Add.
579.5
.05
28.98
New Add.
576.5
.05
28.83
TOTAL Uo x Ao Added
253.91 SF
TOTAL COMBINED
1067.45 SF
-2-
.;h1..- `ttiNWOxr. * AlgiNPO 4401i'■,;:,f on- V:t40a,'
?4AR 2 3 193
M.I36 [DBG /cbj]
ENERGY CODE COMPLIANCE REPORT FOR:
Additions for Tom &.Sandy Barghausen
Lot 14, Silverview
Ring County, Washington
PROJECT DESIGNER:
REPORT PREPARED BY:
Felix L. Touza, P.E.
& S Consulting Engineers
175 E. Olive Ave. # 202
Burbank, CA 91502
(818) 841 0303
Job Number:
Date: 5/13/1993
RECEIVED
CITY OF TUKWILA
MAY 1 4 1993
PERMIT CENTER
The COMPLY 24 computer program has been used to perform the calculations
summarized in this compliance report.
z
w
UO
UD
UW
F=-
W LL.
WO
LL j.
co
=
i- _ W
Z
O
w
w
O ▪ —
O I-
ww
IL. ~O
li l z
• U
O I-;
O
z
WASHINGTON STATE ENERGY CODE
COMPONENT PERFORMANCE APPROACH ANALYSIS FORM
Residential Occupancies
Based on Table 5 -1 of chapter 55 -11 WAC (Washington Energy Code)
For climate Zone 1, Heating with fuels other than electrical
Project: Addition to Tom & Sandy Barghausen's Residence
Compliance based on Section 101.3.2.1 WAC
Conditioned Floor Area:
Component/
Assembly Name
GLAZING
Exercise Room Windows
2nd Flr Addtn Windows
Max. Allowed glazing:
(15% of Addtn.Flr.Area)
Existing Windows
Glass removed by Ex.Rm.
Glass rem'd by 2ndFlr.A
WALLS
Excess glazing( >15% CFA)
Existing Walls
Exercise Room Walls
Walls removed by above
2nd Fl. Addtn Walls
Walls removed by above
DOORS
Main Entry Door
CEILINGS /ROOFS
Existing Roof
Skylight
Exercise Room Roof
2nd Fl. Addtn Roof
2025 SF Existing
452 SF First Addition
258 SF Second Addition
710 SF Total Additions
EXISTING
PLUS CODE - COMPLYING
ADDITION
Area U -Val. UxA
120 - -- - --
264 - -- - --
107 0.650 69.23
813 0.580 471.54
-6 - -- - --
-78 - -- - --
278 0.062
2916 0.059
551 0.062
-230 0.059
344 0.062
-260 0.059
33 0.400
2021 0.035
24 0.580
452 0.034
258 0.034
FLOORS
Existing floor 2025 0.049
Exercise Room floor 452 0.041
2nd F1. Addtn floor 258 0.041
>pv-Ivh?m7ltm kii ra
17.21
172.04
34.16
-13.57
21.33
-15.34
3.3.2
70.74
13.92
15.37
8.77
99.23
18.53
10.58
EXISTING
PLUS NON - COMPLYING
ADDITION
U -Val. UxA
Total Area(Ao): 9957 Tot.0 *A: 1006.92
Standard Uo: 0.1011
Proposed Uo: 0.0966
Standard Uo> Proposed Uo: Building Complies
n;gur�+ kJ.th
0.5800
0.5800
0.5800
0.5800
0.5800
0.0590
0.0590
0.0590
0.0590
0.0590
0.3870
0.0350
0.5800
0.0350
0.0290
0.0000
0.0000
0.0000
Tot.0 *A:
ck i.'`"#�. �.. iepf ,,.1+ _4 . s.a�,. G >K, uyNIiie
69.60
153.12
471.54
-3.48
-45.24
172.04
32.51
-13.57
20.30
-15.34
12.77
70.74
13.92
15.82
7.48
0.00
0.00
0.00
962.21
1
z
w
ce
JU
0
co
CJ
J =
�LL
w o
2
LLj
PROPOSED CONS`T'RUCTION ThSEMBLY
Project Name: Additions for Tom & Sandy Barghausen
Documentation: J & S Consulting Engineers Inc.
Date: 5 /13/1993
COMPLY 24 User 2936
COMPONENT DESCRIPTION
Sketch of Construction Assembly
ASSEMBLY U- VALUE
Construction Components
Assembly Name: R -19 Resdn'tl Wall
Assembly Type: Wall
Assembly Tilt: 90 deg (Vertical)
Framing Material: Wood
Framing Spacing: " O.G.
Framing Percent: 15.0 %
Absorptivity: 0.70
Roughness: Stucco, Wood Shingles
Th R -Value
Fr (in) Cavity Frame
outside Air Film
1. Siding, Wood Shingles 7 1/2" Exposure
2. Plywood
3. Insulation, Mineral Fiber, R- -17.8
4. Gypsum or Plaster Board
5.
6.
7.
8.
9.
Inside Air Film
0.17
0.750 0.87
0.500 0.62
* 5.500 17.80
0.500 0.45
0.17
0.87
0.62
5.45
0.45
0.68 0.68
Unadjusted R- Values
ADIYUSTMENT Piet PRAM /NG
(1 /20.59) x (0.85) + (1 / 8.23) x (0.15) = 0.059
Weight: 8.1 lb /sgft
Heat Capacity: 2.55
;;;;• " •
tAl'ii4ri3i �iFtattiex'�'y'G
20.59 8.23
TOTAL U -VALUE
TOTAL R -VALUE =
.r.�14C3 �'dY' £: 'e?l "y7 :`St'diYi'nII 4 3'4kikS,` S '1 £Q. 1. b"'
Snr
0.059
= = = ==
16.81
z
~
1
w
r QQL
JU
00
CO 0
W =
H
WO
2
1— W
Z
F- O
Z f—
W
W
U �
O N
H
W w
H I-
- O
wz
U -
H
z
PROPOSED CONSTRUCTION ASSEMBLY
Project Name: Additions for Tom & Sandy Barghausen
Documentation: J & s Consulting Engineers Inc.
Date: 5/13/1993
COMPLY 24 User 2936
COMPONENT DESCRIPTION
Sketch of•Construction Assembly
ASSEMBLY U- VALUE
Construction Components
Assembly Name: R -30 Shingle Roof
Assembly Type: Roof
Assembly Tilt: 22 deg (Tilted Up)
Framing Material: Wood
Framing Spacing: " O.C.
Framing Percent: 10.0 %
Absorptivity: 0.70
Roughness: Concrete, Asph. Shingles
Th R -Value
Fr (in) Cavity Frame
Outside Air Film
1. Roofing, Wood Shingles
2. Membrane, Vapor - Permeable Felt
3. Plywood
4. Insulation, Mineral Fiber, R -30
5. Gypsum or Plaster Board
6.
7.
8.
9.
Inside Air Film
0.17
0.750 0.94
0.010 0.06
0.625 0.77
* 9.250 30.00
0.625 0.56
0.17
0.94
0.06
0.77
9.16
0.56
0.61 0.61
Unadjusted R-- Values
ADJUSTMENT FOR FRAMING
(1 /33.12) x (0.90) + (1 /12.27) x (0.10) =
Weight:
9.5 lb /sgft
Heat Capacity: 2.95
0.035
33.12 12.27
TOTAL U -VALUE =
TOTAL R -VALUE =
!UtitfiiFv,�•.TMSf: ic•?ifi':?t tAVVIIVAMISIV
0.035
28.31
z
~ w
re
JU
00
U) 0
J =
H
U) u_
w0
2
�_
(f)d
=w
I- _
Z_
1- 0
Z 1-
(11
W
0
0-
0 1-
ww
u' O
w
..z
co
01—
z
PROPOSED CONSTRUCTION ASSEMBLY
Project Name: Additions for Tom & Sandy Barghausen
;Date: 5/13/1993
Documentation: J & S Consulting Engineers Inc. ;COMPLY 24 User 2936
COMPONENT DESCRIPTION
Sketch of Construction Assembly
ASSEMBLY U -VALUE
Construction Components
Assembly Name: R-38 Shingle Roof
Assembly Type: Roof
Assembly 'tilt: 22 deg (Tilted Up)
Framing Material: Wood
Framing Spacing: " O.C.
Framing Percent: 10.0 %
Absorptivity: 0.70
Roughness: Concrete, Asph. Shingles
Th R -Value
Fr (in) Cavity Frame
Outside Air Film
1. Roofing, Wood Shingles
2. Membrane, Vapor - Permeable Pelt
3. Plywood
4. Insulation, Mineral Fiber, R -38
5. Gypsum or Plaster Board
6.
7.
8.
9.
Inside Air Film
0.17
0.750 0.94
0.010 0.06
0.625 0.77
* 11.500 38.00
0.625 0.56
0.17
0.94
0.06
0.77
11.39
0.56
0.61 0.61
Unadjusted R- Values
ADJUSTMENT FOR PRAMING
(1 /41.12) x (0.90) + (1 /14.50) x (0.10) _
Weight:
10.3 lb /sqft
Heat Capacity: 3.22
0.029
41.12 14.50
TOTAL U -VALUE _
TOTAL R- -VALUE _
0.029
34.74
PROPOSED CONSTRUCTION ASSEMBLY
Project Name: Additions for Tom & Sandy Barghausen
Documentation: J & S Consulting Engineers Inc.
Date: 5/13/1993
COMPLY 24 User 2936
COMPONENT DESCRIPTION
Sketch of Construction Assembly
ASSEMBLY U--VALUE
Construction Components
Outside Air Film
1. Insulation, Mineral Fiber,
2. Plywood
3. Flooring, Carpet and Fibrous
4.
5.
6.
7.
8.
9.
Inside Air Film
6
Assembly Name: R -19 Floor(F.19.2x8.16)
z
Assembly Type: Floor = H
Z
Assembly Tilt: 180 deg (Horizontal Floor) c
JU
Framing Material: Wood 0 0
cnw
Lux
Framing Spacing: O.C.
O.C.
co u_
Framing Percent: 10.0 % w 0
Absorptivity: 0.70
Roughness: Stucco, Wood Shingles
�0
zI-
Th R- Value. LLJ
Fr (in) Cavity Frame
O • S2
0.17 0.17 01_
R -19 * 6.000 19.00 5.94 w w
0.625 0.77 0.77 2
Pad 0.250 2.08 2.08 • Z
w
U=
O F-
0.92 0.92
Unadjusted R- Values
22.95 9.89
ADJUSTMENT FOR FRAMING
(1 /22.95) x (0.90) + (1 / 9.89) x (0.10) = 0.049
TOTAL U -VALUE = 0.049
Weight:
Heat Capacity: 1.27
TOTAL R -VALUE = 20.27
3.9 lb /sgft
A
z
PROPOSED CONSTRUCTION ASSEMBLY
Project Name: Additions for Tom & Sandy Barghausen
Documentation: J & S Consulting Engineers Inc.
Date: 5/13/1993
COMPLY 24 User 2936
COMPONENT DESCRIPTION
Sketch of Construction Assembly
ASSEMBLY U -VALUE
Construction Components
Outside Air Film
1. Softwood, Douglas Fir -Larch
2.
3.
4.
5.
6.
/.
8.
9.
Inside Air Film
Assembly Name: Solid Wood Door
z
Assembly Type: Door 1 z
w
Assembly Tilt: 90 deg (Vertical) �
Framing Material: None 0 0
co LU
Framing Spacing: " O.C. _I Ill F-
a) w
Framing Percent: 0.0 % w O
2
Absorptivity: 0.70 g Q
Roughness: Glass, Paint on Pine H
z=
1- O
Z I-
Th R -Value w
Fr (in) Cavity Frame 0 o
ON
0.17 0.17 at-
1.750 1.73 1.73 w w
11 0
.Z
U=
0 O ~
0.68 0.68
Unadjusted R- Values
2.58 2.58
ADJUSTMENT FOR FRAMING
(1 / 2.58) x (1.00) + (1 / 2.58) x (0.00) = 0.387
TOTAL U -VALUE =
Weight: 5.1 lb /sgft
Heat Capacity: 1.99
TOTAL R -VALUE =
0.387
2.58
z
HVAC ZONE HEATING & COOLING LOAD SUMMARY
Project Name: Additions for Tom & Sandy Barghausen
Documentation: J & S Consulting Engineers Inc.
;Date: 5/13/1993
i
;COMPLY 24 User 2936
HVAC ZONE DESCRIPTION
HVAC Zone Name:
Heating System Name:
Cooling System Name:
System Multiplier:
Fan Schedule:
Peak Load Method:
Relative Humidity:
SPACES IN THIS ZONE
Existing Residence
Exercise Room
Addition to 2nd Story
Whole House
YORK B2CH060A06
1
All On Load Calcs
COINCIDENT
50 %
COOLING
PEAK HEATING PEAK SENSIBLE LATENT
(Jan 12am)
(Jan 12am)
(Jan 12am)
67997 (Aug 2pm)
12571 (Aug 2pm)
10156 (Aug 2pm)
TOTAL SPACE LOAD 90724
40458
8184
13918
4158
928
530
62560 5616
Duct Gains & Losses: 9072 6256
Return Air Lighting Gain 0
TOTAL SYSTEM LOAD 99796
SYSTEM OUTPUT AT DESIGN CONDITIONS 55330
68816 5616
46430 18627
NOTE: The TOTAL SYSTEM LOAD shown represents the minimum size equipment
which will heat or cool this zone during the design conditions indicated.
These numbers include no safety factor, and the HVAC contractor should
oversize by a reasonable margin to account for variations in weather
conditions and the pick -up capacity required to bring the zone to temper-
ature as a result of a setback thermostat. Those responsible for final
equipment selection should note that Sensible and Latent Cooling Loads are
indicated to allow for accurate comparison with manufacturer's output data.
vfit,,.;:,.tt 11.514 .I'i'li t? i ?4%i "ent' f•1;4`�cwF:J « +��i" r),Xa}.�i+ "y; ,b'yh�, � i1t S'Sit °
?attt},".!ty*.m.I.'Y 3}Sl:Ytai i�
z
~ w
6
00
co
Ww
J F
w • 0
u.
=• d
z1._
I- 0
z I-
LL'
w
Uo
0—
o-
wW
u. O
wz
U2
P. _
O~
z
RESIDENTIAL SPACE HEATING LOAD SUMMATW
Project Name: Additions for Tom & Sandy Barghausen
Documentation: J & S Consulting Engineers Inc.
Space Name:
Date: 5/13/1993
COMPLY 24 User 2936
Design Indoor Dry Bulb Temperature:
Design Outdoor Winter Dry Bulb Temperature:
Design Temperature Difference:
Conduction
R -19 Resdn'tl Wall
Solid Wood Door
Double Clear (NR Std)
Double Clear (NR Std)
R -30 Shingle Roof
R -19 Floor(F.19.2x8.16)
Infiltration: 1.00 x 0.018 x
Ventilation: 1.072 x
Heating AirFlow:
Existing Residence
Area U -Value
2916.0 x 0.0595
33.0 x 0.3872
740.0 x 0.8800
73.0 x 0.7200
2025.0 x 0.0353
2025.0 X 0.0493
2025 sf x 9.0 ft x 0.50 AC
2025 sf x 20.0 cfm / 100.0
x
x
x
x
68 F
27 F
41 F
�ru
NIP .. T.
41.0
41.0
41.0
41.0
41.0
41.0
x 41.0
x 41.0 =
TOTAL HOURLY HEAT LOSS FOR SPACE
Btu /hr
7113
524
26699
2155
2933
4095
6676
17802
67997
67997 Btu /hr / (1.07 x 37 F DeltaT)] 1714 cfm
RESIDENTIAL SPACE COOLING LOAD SUMMARY
Project Name: Additions for Tom & Sandy Barghausen
Documentation: J & S consulting Engineers Inc.
Date: 5/13/1993
COMPLY 24 User 2936
Space Name:
Existing Residence
Design Indoor Dry Bulb Temperature: 78
Design Outdoor Summer Dry Bulb Temperature: 82
Design Temperature Difference: 4
Conduction
R -19 Resdn't1 Wall
Solid Wood Door
Double Clear (NR Std)
Double Clear (NR Std)
R -30 Shingle Roof
R--19 Floor(F.19.2x8.16)
Infiltration: 0.00 x 0.018 x 2025 sf
Ventilation: 1.072 x 2025 sf
Solar Gain
Orient.
*Double Clear
Double Clear
Internal Gain
(NR Std) North
(NR Std) North
Lighting
Equipment
Occupants
Latent Gain
Equipment
Occupants
Infiltration:
Ventilation:
Op Frac.
1.00
0.00
1.00
Area
2916.0
33.0
740.0
73.0
2025.0
2025.0
F
U -Value DETD Btu /hr
x 0.0592, x 5.1 = 885
x 0.3872 x 5.1 = 65
x 0.8800 x 4.0 = 2605
x 0.7200 x 4.0 - 210
x 0.0353 x 25.5 = 1824
x 0.0493 x 0.0 = 0
x 9.0 ft
x 20.0 cfm
Shaded
Area SGF
0.0 x 15 +
0.0 x 15 +
Area
x 2025.0
x 2025.0
x 2025.0
x 0.50 AC x 4.0 - 0
/ 100.0 x 4.0 = 1737
Unshaded
Area SGF SC
740.0 x 15] x 0.55 = 6105
73.0 x 15] x 0.88 = 964
Heat Gain Cony.
x 3.000
x 0.000
x 225
x
x
3.413
3.413
100
TOTAL HOURLY SENSIBLE HEAT GAIN FOR SPACE
Op Frac. Area Heat Gain Cony.
0.00 x 2025.0 X 0.000 x 3.413
1.00 x 2025.0 x 225 / 100
0.00 x 0.018 x 2025 sf x 9.0 ft x 0.50 AC x -0.8
1.072 x 2025 sf x 20.0 cfm / 100.0 x -0.8
TOTAL HOURLY LATENT HEAT GAIN FOR SPACE
20734
0
4556
40458
Btu/hr
0
4556
-0
-366
4158
Cooling AirFlow: 40458 Btu /hr / [1.07 x 23 F Delta'r)) = 1641 cfm
RESIDENTIAL SPACE HEATING LOAD SUMMARY
Project Name: Additions for Tom & Sandy Barghausen
Documentation: J & S Consulting Engineers Inc.
Date: 5/13/1993
COMPLY 24 User 2936
Space Name: Exercise Room
Design Indoor Dry Bulb Temperature:
Design Outdoor Winter Dry Bulb Temperature:
Design Temperature Difference:
Conduction
R -19 Resdn'tl Wall
Double Clear (NR Std)
Double Clear (NR Std)
R-38 Shingle Roof
R -19 Floor(F.19.2x8.16)
Infiltration: 1.00 x 0.018 x
Ventilation: 1.072 x
'Heating AirFlow:
452 sf
452 sf
68 F
27 F
41 F
Area U -Value TD Btu /hr
579.0 x 0.0595 x 41.0 = 1412
103.0 x 0.8800 x 41.0 3716
18.0 x 0.7200 x 41.0 = 531
452.0 x 0.0288 x 41.0 = 533
452.0 x 0.0493 x 41.0 914
x 9.0 ft x 0.50 AC x 41.0 = 1490
x 20.0 cfm / 100.0 x 41.0 = 3974
TOTAL HOURLY HEAT LOSS FOR SPACE 12571
12571 Btu/hr / [1.07 x 37 F DeltaT)) = 317 cfm
RESIDENTIAL SPACE COOLING LOAD SUMMARY
Project Name: Additions for Tom & Sandy Harghausen
Documentation: J & S Consulting Engineers Inc.
1Date: 5/13/1993
i
;COMPLY 24 User 2936
Space Name:
Exercise Room
Design Indoor Dry Bulb Temperature: 78
Design Outdoor summer Dry Bulb Temperature: 82
Design Temperature Difference: 4
Conduction
R -19 Resdn'tl Wall
Double Clear (NR Std)
Double Clear (NR Std)
R -38 Shingle Roof
R -19 Floor(F.19.2x8.16)
Infiltration: 0.00 x 0.018 x 452 sf
Ventilation: 1.072 x 452 sf
Solar Cain
Orient.
Double Clear
Double Clear
Internal Gain
(NR Std) North
(NR Std) North
Lighting
Equipment
Occupants
Latent Gain
Equipment
Occupants
Infiltration:
Ventilation:
Op Frac.
F
F
F
Area U -Value DETD Btu /hr
579.0 x
103.0 x
18.0 x
452.0 x
452.0 x
x 9.0 ft
x 20.0 cfm
Shaded
Area SGF
1.00 x
0.00 x
1,00 x
0.0 x 15 +
0.0 x 15 +
Area
X
0.0595
0.8800
0.7200
0.0288
0.0493
x 5.1 = 176
X 4.0 - 363
x 4.0 = 52
x 25.5 = 332
x 0.0 = 0
0.50 AC x
100.0 x
4.0 - 0
4.0 = 388
Unshaded
Area SGF SC
103.0 x 153 x 0.55 = 850
18.0 x 15] x 0.88 = 238
Heat Gain Conv.
452.0 x 3.000 x 3.413
452.0 x 0.000 x 3.413
452.0 x 225 / 100
TOTAL HOURLY SENSIBLE HEAT GAIN FOR SPACE
Op Frac. Area Heat Gain Conv.
0.00 x 452.0 x 0.000 x 4.413
1.00 x 452.0 x 225 / 100
0.00 x 0.018 x 452 sf x 9.0 ft x 0.50 AC x -0.8
1.072 x 452 sf x 20.0 cfm / 100.0 x -0.8
Cooling AirFlow:
.:2t4,,S-;; sly z '0:,44',, ihr1 .;;l V UN',.'i4a4n.Si +J.:t
TOTAL HOURLY LATENT HEAT GAIN FOR SPACE
4628
0
• 1017
8184
Btu /hr
0
• 1017
-0
• -82
928
8184 Btu /hr / [1.07 x 23 F DeltaT) ] = 332 cfm
Iu
z
1
w
ct 3_
00
-
t-
cu.
w0
2
g<
I
z
z1-
w
U�
O -
• H
wW
• O
wz
U=
O~
z
RESIDENTIAL SPACE HEATING LOAD SUMMARY
Project Name: Additions for Tom & Sandy Barghausen
Documentation: J & S Consulting Engineers Inc.
Date: 5/13/1993
COMPLY 24 User 2936
Space Name:
' Z
Design indoor Dry Bulb Temperature: 68 %27 F
Design Outdoor Winter Dry Bulb Temperature: 41 F F-w
Design Temperature Difference: Waa z
JU
Conduction Area U -Value TD Btu /hr
U0
- - --
16 629.0 X 0.0792 x 41.0 = 2042 N z
R -13 ShearWall(W2x4. )
Double Clear (NR Std) 116.0 x 0.8800 x 41.0 _ 4185 w o
R -42 Shingle Roof 258.0 x 0.0273 x 41.0 = 288
258.0 x 0.0493 X 41.0 522 5
R -19 Floor(F.19.2x8.16) u.
Infiltration: 1.00 x 0.018 x 258 sf x 9.0 ft x 0.50 AC x 41.0 = 851 = w
Ventilation: 1.072 x 258 sf x 20.0 cfm / 100.0 x 41.0 = 2268 F._
zi._
TOTAL HOURLY HEAT LOSS FOR SPACE 10156 Z 1-0
w
Heating AirFlow:
10156 Btu /hr / (1.07 x 37 F DeltaT)] = 256 cfm D 0
0I-
wW
~E=
�O
aim
U=
0 I-
z
Addition to 2nd Story
RESIDENTIAL SPACE COOLING LOAD SUMMARY
Project Name: Additions for Tom & Sandy Sarghausen
Documentation: J & S Consulting Engineers Inc.
bate: 5/13/1993
COMPLY 24 User 2936
Space Name:
Design Indoor Dry Bulb Temperature:
Design Outdoor Summer Dry Bulb Temperature:
Design Temperature Difference:
Conduction
R -13 ShearWall(W2x4.16)
Double Clear (NR Std)
R -42 Shingle Roof
R -19 Floor(F.19.2x8.16)
Infiltration: 0.00 x 0.018 x 258 sf
ventilaticn: 1.072 x 258 sf
Addition to 2nd Story
78 F
82 F
4 F
Area U-Value DETD
629.0 x 0.0792 x 5.1
116.0 x 0.8800 x 4.0
258.0 x 0.0273 x 25.5
258.0 x 0.0493 x 0.0
x 9.0 ft x 0.50 AC x
x 20.0 cfm / 100.0 X
Shaded
Solar Gain Orient. Area SGF
Double Clear (NR Std) West [ 0.0 x 15
Internal Gain
Lighting
Equipment
Occupants
Latent Gain
Equipment
occupants
Infiltration:
Ventilation:
4.0
4.0
Unshaded
Area SGF SC
Btu /hr
254
408
179
0
0
221
+ 116.0 x 73) X 0.55 = 4657
Op Frac. Area Heat Gain Conv.
1.00 x
1.00 x
1.00 x
258.0
258.0
258.0
x 0.457 x 3.413
x 8.000 x 3.413
x 225 / 100
TOTAL HOURLY SENSIBLE HEAT GAIN FOR SPACE
Op Frac. Area Heat Gain Conv.
1.00
1.00
0.00 x 0.018 x 258
1.072 x 258
x 258.0 x 0.000 x 3.413
x 258.0 x 225 / 100
sf x 9.0 ft x 0.50 AC x -0.8
sf x 20.0 cfm / 100.0 x -0.8
TOTAL HOURLY LATENT HEAT GAIN FOR SPACE
403
7044
581
13918
Btu/hr
0
581
-0
-47
Cooling AirFlow: 13918 Btu /hr / (1.07 x 23 F DeltaT)j = 564 cfm
530
z
ce w
QQ�
JU
O 0
co
J z
F-
w 0
d
1- w
z=
w1-
U• �
O -
O E-
w W
11O
wz
U=
0
z