Loading...
HomeMy WebLinkAboutPermit D06-464 - Westfield Southcenter Mall - Gamestop - WallGAMESTOP 1068 Southcenter mall D06 -464 Parcel No.: 2623049023 Address: 1068 SOUTHCENTER MALL TUKW Suite No: Contact Person: Name: AMY BOUWMAN Address: 75 60 ST SW , WYOMING MI 49548 Phone: 800 285 -7866 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite 11100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us Tenant: Name: GAMESTOP Address: 1068 SOUTHCENTER MALL , TUKWILA WA Owner: Name: WESTFIELD CORPORATION LLC Address: 11601 WILSHIRE BL , LOS ANGELES CA 90025 Phone: Contractor: Name: L & L RETAIL CONSTRUCTION LLC Address: 3750 W MAIN ST STE 4A , NORMAN OK 73072 Phone: 405 360 -2775 Contractor License No: LLRETCL954QQ DEVELOPMENT PERMIT DESCRIPTION OF WORK: TENANT IMPROVEMENT: MOVING DEMISING WALL TO CREATE SMALLER TENANT SPACE Value of Construction: 928,000.00 Fees Collected: $825.38 Type of Fire Protection: SPRINKLERS International Building Code Edition: 2003 Type of Construction: IIB Occupancy per IBC: 0019 * *continued on next page ** Permit Ntunber: D06 -464 Issue Date: 01/18/2007 Permit Expires On: 07/17/2007 Expiration Date: 11/18/2007 Steven M. Mullet, Mayor Steve Lancaster, Director doc: IBC -10/06 D06 -464 Printed: 01 -18 -2007 Public Works Activities: Cltannelization / Striping: N Curb Cut / Access / Sidewalk / CSS: N City of Tukwila Department of Community Development Steve Lancaster, Director 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us Fire Loop Hydrant: N Number: 0 Size (Inches): 0 Flood Control Zone: Hauling: N Start Time: End Time: Land Altering: Volumes: Cut 0 c.y. Fill 0 c.y. Landscape Irrigation: Moving Oversize Load: Start Rime: End Time: Sanitary Side Sewer: Sewer Main Extension: Private: Public: Storm Drainage: Street Use: Profit: N Non - Profit: N Water Main Extension: Private: Public: Water Meter: Permit Center .Authorized Signature I hereby certify that I have read an governing this work will be compli N LA 1-ILA The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the - rfonnance • work. . thorized to sign and obtain this development permit. Signature: Date: / ^ /2 - O Permit Number: D06 - 464 Issue Date: 01/18/2007 Permit Expires On: 07/17/2007 Date: 01 V t' t't - Steven M Mullet, Mayor permit and lmow the same to be true and correct. All provisions of law and ordinances er specified herein or not. Print Name: i / 4\ rS f e u> a ✓'I This permit shall become null and void if the work is not commenced within 180 days front the date of issuance, or if the work is suspended or abandoned for a period of 180 days front the last inspection. doc: IBC -10 /06 D06 -464 Printed: 01 -18 -2007 Parcel No.: 2623049023 Address: 1068 SOUTECENTER MALL TUI{W Suite No: Tenant: GAMESTOP 1: ** *BUILDING DEPARTMENT CONDITIONS * ** City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us PERMIT CONDITIONS Permit Number: D06 - 464 Status: ISSUED Applied Date: 12/14/2006 Issue Date: 01/18/2007 2: No changes shall be made to the approved plans unless approved by the design professional in responsible charge and the Building Official. 3: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center (206/431 - 3670). 4: All permits, inspection records, and approved plans shall be at the job site and available to the inspectors prior to start of any construction. These documents shall be maintained and made available until final inspection approval is granted. 8: New suspended ceiling grid and light fixture installations shall meet the non - building strictures seismic design requirements of ASCE 7. 6: Partition walls that are tied to the ceiling and all partitions greater than 6 feet in height shall be laterally braced to the building structure. 7: All construction shall be done in conformance with the approved plans and the requirements of the International Building Code or International Residential Code, International Mechanical Code, Washington State Energy Code. 8: There shall be no occupancy of a building until final inspection has been completed and approved by Tukwila building inspector. No exception. 9: Ventilation is required for all new rooms and spaces of new or existing buildings and shall be in conformance with the International Building Code and the Washington State Ventilation and Indoor Air Quality Code. 10: Water heaters shall be anchored or strapped to resist horizontal displacement due to earthquake motion Strapping shall be at points within the upper one -third and lower one -third of the water heater's vertical dimension. A minimum distance of 4- inches shall be maintained above the controls with the strapping. 11: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the Cityof'lwkwila Permit Center. 12: All electrical work shall be inspected and approved under a separate permit issued by the Washington State Department of Labor and Industries (206/248 - 66330). 13: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. 14: ** *FIRE DEPARTMENT CONDmONS * ** 15: The attached set of building plans have been reviewed by the Fire Prevention Bureau and are acceptable with the doc: Cond -10 /06 006 -464 Printed: 01 -18 -2007 following concerns: City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite /1100 Tukwila, Washington 98188 Phone: 206- 431 -3670 Fax: 206 - 431 -3665 Web site: http.: / /www.ci.tukwila.wa.us 16: The total number of fire extinguishers required for an ordinary hazard occupancy with Class A fire hazards is calculated at one extinguisher for each 1,500 sq. ft. of area. The extinguisher(a) should be of the "All Purpose" (2A, 20B:C) dry chemical type. Travel distance to any fire extinguisher must be 75' or less. (IPC 906.3) (NFPA 10, 3 -2.1) 17: Portable fire extinguishers, not housed in cabinets, shall be installed on the hangers or brackets supplied. Hangers or brackets shall be securely anchored to the mounting surface in accordance with the manufacturer's installation instructions. Portable fire extinguishers having a gross weight not exceeding 40 pounds (18 kg) shall be installed so that its top is not more than 5 feet (1524 nun) above the floor. Hand -held portable fire extinguishers having a gross weight exceeding 40 pounds (18 kg) shall be installed so that its top is not more than 3.5 feet (1067 mm) above the floor. The clearance between the floor and the bottom of the installed hand -held extinguishers shall not be less than 4 inches (102 nun). arc 906.7 and 1FC 906.9) 18: Fire extinguishers shall not be obstructed or obscured from view. In rooms or areas in which visual obstruction cannot be completely avoided, means shall be provided to indicate the locations of the extinguishers. (IFC 906.6) 19: Extinguishers shall be located in conspicuous locations where they will be readily accessible and immediately available for use. These locations shall be along normal paths of travel, unless the fire code official determines that the hazard posed indicates the need for placement away from normal paths of travel. (IFC 906.5) 20: Fire extinguishers require monthly and yearly inspections. They must have a tag or label securely attached that indicates the month and year that the inspection was performed and shall identify the company or person performing the service. Every six years stored pressure extinguishers shall be emptied and subjected to the applicable recharge procedures. If the required monthly and yearly inspections of the fire extinguisher(s) are not accomplished or the inspection tag is not completed, a reputable fire extinguisher service company will be required to conduct these required surveys. (NFPA 10, 4 -3, 4-4) 21: Egress doors shall be readily openable from the egress side without the use of a key or special knowledge or effort. (IFC 1008.1.8.3 subsection 2.2) 22: Dead bolts are not allowed on auxiliary exit doors unless the dead bolt is automatically retracted when the door handle is engaged from inside the tenant space. (IFC Chapter 10) 23. Door handles, pulls, latches, locks and other operating devices on doors required to be accessible by Chapter 11 of the International Building Code shall not require tight grasping, tight pinching or twisting of the wrist to operate. (1FC 1008.1.8.1) 24: Exit hardware and marking shall meet the requirements of the International Fire Code. (WC Chapter 10) 25: Maintain sprinkler coverage per N.F.P.A. 13. Addition/relocation of walls, closets or partitions may require relocating and/or adding sprinkler heads. (IFC 901.4) 26: All electrical work and equipment shall conform strictly to the standards of the National Electrical Code. (NFPA 70) 27: New and existing buildings shall have approved address numbers, building numbers or approved building identification placed in a position that is plainly legible and visible from the street or road fronting the property. These numbers shall contrast with their background. Address numbers shall be Arabic numbers or alphabet letters. Numbers shall be a minimum of 4 inches (102mm) high with a minimum stroke width of 0.5 inch (12.7mm). (IFC 505.1) 28: Per Westfield, this is a temporary space for Gamestop. Therefore, fire alarm notification upgrade not required. 29: Contact The Tukwila Fire Prevention Bureau to witness all required inspections and tests. (City Ordinances #2050 and #2051) doc: Cond -10/06 D06-464 Printed: 01 -18 -2007 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Fax: 206 - 431 -3665 Web site: http: / /www.cttukwila.wa.us 30: Any overlooked hazardous condition and/or violation of the adopted Fire or Building Codes does not imply approval of such condition or violation. 31: These plans were reviewed by Inspector 511.1f you have any questions, please call Tukwila Fire Prevention Bureau at (206)5754407. * *continued on next page ** doc: Cand -10/06 006-464 Printed: 01 -18 -2007 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us I hereby certify that I have read these conditions and will comply with them as outlined. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provision of any other work or local laws regulating construction or the performance of work. Signature: Print Name: it— ef , , s71 9 4_7 A Date: / /9 'a 7 doc: Cond -10 /06 1306.464 Printed: 01 -18 -2007 SITE LOCATION King Co Assessor's Tax No.: Site Address: IOIO'R :Ca 111'1 (Teflkv )Jl i 1 ' Suite Number. g06 Tenant Name: 6Yt.t't'1PS'(-ekt V�p /� 1 i Property Owners Name: St- 1 A 12 mom -14 Cr' Mailing Address: 1 1 1001 W 1.SIni ce Lim l/ ) Q CONTACT PERSON - who do we contact when your permit is ready to be issued CITY OF TUKWILk. Community Development Department Public Works Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 htp: / /www.ci.tukwila.wa.us Name: 'f-)I/i(.j PA, D/17&Mm Day Telephone: -c4 state 41.019 Zip E -Mail Address: girn6b& ,,' (S‘tOr )fc'M S. Corn Fax Number: Lolfo /93 -936 Mailing Address: " 76 - - 50,1 Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. **Please Print" GENERAL CONTRACTOR INFORMATION — (Contraetor Information for Mechanical (pg 4) for Plumbing and Gas Piping (pg 5)) Company Name: Mailing Address: Contact Person- E-Mail Address: Contractor Registration Number: ARCHITECT OF RECORD - All plans must be wet stamped by Architect of Record 1 Company Name: - Fit'- E.LKIS f 7 • 0tsk■ 0. Mailing Address: V1W) etts ) Q rb rQ E • 3f-U Contact Person: XCICNX.Ctri 9(YN.V c t E -Mail Address; NY if ✓ e o1,YcV. w rl Contact Person: E-Mail Address: Q:UpplieariaosWam.•Applia6me Qs linel7 -2006 - Permit Applivaon :doe Revised: 9.1006 bh 4 / 1- 1 M. (0 -- I Plumbing/Gas Permit No. 1`I i af' - `L�n Building PerStNo. Mechanical Permit No. Public Works Permit No. Project No. (For office use only) New Tenant: /sa Floor: State City Day Telephone: Fax Number: Expiration Date: State Qty State Zip Day Telephone: 8N- 41s '.an Fax Number: 31y't// -- ENGINEER OF RECORD - All plans mast be wet stamped by Engineer of Record Company Name: Mailing Address: City Day Telephone: Fax Number: State Yes ❑.. No qa- Zip Zip Page 1 of 6 BUILDING PERMIT INFORM.,./ION — 206 - 431 -3670 ‘ Valuation of Project (contractor's bid price): $ ale I ix1O __ 1 ` Existing Building Valuation: $ Scope of Work (please provide detailed information): —k hit 1C`tl- eJr G, 4 n , , Js _ t un4 Q-n fiJ na ' (S SF) , 1- ouldlortQ I's re dem; si'n5 1-1- to Moo sr .4.)r our5 2ct„ `fhe_ res+ k»11 baome JcPenri -ey storetyc, Will there be new rack storage? ❑ Yes ®.. No If yes, a separate permit and plan submittal will be required. Provide All Building Areas in Square Footage Below PLANNING DIVISION: Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) *For an Accessory dwelling, provide the following: Lot Area (sq ft): Floor area of principal dwelling: Floor area of accessory dwelling: *Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard: Compact: Handicap: Will there be a change in use? ❑ Yes No If des ", explain: FIRE PROTECTION/HAZARDOUS MATERIALS: Sprinklers ❑ Automatic Fire Alarm ❑ None ❑ Other (specify) Will there be storage or use of flammable, combustible or hazardous materials in the building? ❑ Yes No If 'yes', attach list of materials and storage locations on a separate 8 -1/2 "x 11" paper including quantities and Material Safe Data Sheets. SEPTIC SYSTEM ❑ On -site Septic System — For on -site septic system, provide 2 copies of a current septic design approved by King County Health Department. QUpplic do sTmms -Appli miens On LioeV -2006 - Permit Apyacstim.doc Revised: 9-2006 bb Page 2 of 6 PUBLIC WORKS PERMIT INRMATION — 206- 433 -0179 Scope of Work (please provide detailed information): - atPfry). n )v' t& F%fl\ a L t i ni 5 L014 QAA eAGVfin q 61:0 s4 —I ItC: S -c-h ' Sici lac 'b Iboo S *r our c:cc.. ` n- c- 're tt \\ t e(o tyv jekr\Ita9 n ra c W ter Dis i t ...Tukwila ❑...Water District #125 ❑ .. Highline ❑ ...Water Availability Provided werDs it ...Tukwila ❑... ValVue ❑ .. Renton 0.. Seattle ❑...Sewer Use Certificate ❑...Sewer Availability Provided Septic System: L,J On -site Septic System — For on - site septic system, provide 2 copies of a current septic design approved by King County Health Department ubmitted with Application (mark boxes which apply): all ...Civil Plans (Maximum Paper Size — 22" z 34 ") ❑ ...Technical Information Report (Storm Drainage) ❑ .. Geotecbnical Report ❑ ...Bond ❑ .. Insurance ❑ .. Easement(s) ❑ .. Maintenance Agreement(s) Pr nosed Activities (mark boxes that apply): ...Right-of-way Use - Nonprofit for less than 72 hours ❑ ...Right-of-way Use - No Disturbance ❑ ... Construction /Excavation/Fill - Right-of-way Non Right -of-way ❑ ...Total Cut ❑ ...Total fill Please refer to Public Works Bulletin #1 for fees and estimate sheet. cubic yards cubic yards ❑...Sanitary Side Sewer ❑ ❑...Cap or Remove Utilities ❑ ❑...Frontage Improvements ❑ ❑ ...Traffic Control ❑ ❑ ...Backflow Prevention - Fire Protection Irrigation Domestic Water ❑...Permanent Water Meter Size... ❑ ...Temporary Water Meter Size .. " ❑ ...Water Only Meter Size " ❑ ...Sewer Main Extension Public _ ❑...Water Main Extension Public Q:Uppticadaaa'ams-Appaeadaa On Iinep -206 - Permit Appaeadan.doc Revised. 9-2006 bb .. Abandon Septic Tank .. Curb Cut .. Pavement Cut .. Looped Fire Line Call before you Dig: 1400 -424 -5555 ❑ .. Renton ❑ .. Right-of-way Use - Profit for less than 72 hours ❑ .. Right-of-way Use — Potential Disturbance ❑ .. Work in Flood Zone ❑ .. Storm Drainage WO # WO # WO # ❑...Deduct Water Meter Size Private Private 0... Traffic Impact Analysis 0... Hold Harmless — (SAO) ❑...Hold Harmless — (ROW) ❑ .. Grease Interceptor ❑ .. Channelization ❑ .. Trench Excavation ❑ .. Utility Undergrounding FINANCE INFORMATION Fire Line Size at Property Line Number of Public Fire Hydrant(s) ❑...Water ❑...Sewer 0 ...Sewage Treatment Monthly Service Billine to: Name: Day Telephone: Mailing Address: Water Meter Refund/Billing: Name: Mailing Address: city Day Telephone: City State State Zip Zip Page 3 of 6 Unit Type: Qtv Unit Type: Qty Unit Type: Qty Boiler /Compressor: Qty Fumace<100K BTU Air Handling Unit >10,000 CFM Fire Damper 0-3 HP /100,000 BTU Furnace>100K BTU Evaporator Cooler Diffuser 3 -15 11P /500,000 BTU Floor Furnace Ventilation Fan Connected to Single Duct Thermostat 15 -30 HP /1,000,000 BTU Suspended/WalliFloor Mounted Heater Ventilation System Wood/Gas Stove 30-50 HP/1,750,000 BTU Appliance Vent Hood and Duct Emergency Generator 50+HP /1,750,000 BTU Repair or Addition to Heat/Refrig/Cooling System Incinerator - Domestic Other Mechanical Equipment Air Handling Unit <10,000 CFM 1 1 Incinerator — Comm/lnd MECHANICAL PERMIT INFb fATION - 206 -431 -3670 49 MECHANICAL CONTRACTOR INFORMATION Company Name: Mailing Address: City State Zip Contact Person: Day Telephone: E -Mail Address: Fax Number: Contractor Registration Number: Expiration Date: Valuation of Mechanical work (contractor's bid price): S t Oft) Scope of Work (please provide detailed information). ';-PXlet v n )a e Yet 4 \on Use: Residential: New .... ❑ Replacement.... Commercial: New .... ❑ Replacement Type: Electric ❑ Gas....❑ Other: =ICI'AA 0 Indicate type of mechanical work being installed and the quantity below: Q: ApplicetiaaWams- Applications Oit 17mU -3006 - Permit MNieetio doe Rtri ed: 9-2006 bb Page 4 of 6 Fixture Type: Qty Fixture Type: Qty Fixture Type: Qty Fixture Type: Qty Bathtub or combination bath/shower Drinking fountain or water cooler (per head) Wash fountain Gas piping outlets Bidet Food -waste grinder, commercial Receptor, indirect waste Clothes washer, domestic Floor drain 1 Sinks Dental unit, cuspidor Shower, single head trap Urinals Dishwasher, domestic, with independent drain Lavatory i Water Closet 1 Building sewer or trailer park sewer Rain water system — per drain (inside building) Water heater and/or vent Additional medical gas inlets/outlets — six or more Industrial waste pretreatment interceptor, including its trap and vent, except for kitchen type grease interceptors Repair or alteration of water piping and/or water treating equipment Repair or alteration of drainage or vent piping Medical gas piping system serving one to five inlets/outlets for specific gas PLUMBING AND GAS PO'INeSERMIT INFORMATION — 206- 431*670 PLUMBING AND GAS PIPING CONTRACTOR INFORMATION Company Name: Mailing Address: Coy atek za Contact Person: Day Telephone: E -Mail Address: Fax Number: Contractor Registration Number. Expiration Date: Valuation of Plumbing work (contractor's bid price): $ 55 pm Valuation of Gas Piping work (contractor's bid price): $ Scope of Work (please provide detailed information): AY MCA A )Mrce -I , y \' S vaS an cc ( fi t tot s � scoot l.s e M • °1/4\--c 1-tx ni� lhat g > e_- �1tnewt n 'i i 1006 �P J �0 t ( e « \\ \ e Writ -1C- - crl1leA- er v y Building Use (per Int'I Building Code): 'M Occupancy (per Int'l Building Code): N% Utility Purveyor: Water: Sewer: Indicate type of plumbing fixtures and/or gas piping outlets being installed and the quantity below: Q: MpplleeriaaWonorAppliaeae On Beau -x006 -Pamir Applimice.dec Revised: 9-2006 bi Page 5 of PERMIT APPLICATION NOTES — Applicable to all permits in this application Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. Building and Mechanical Permit The Building Official may grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). Plumbing Permit The Building Official may grant one extension of time for an additional period not exceeding 180 days. The extension shall be requested in writing and justifiable cause demonstrated. Section 103.4.3 Uniform Plumbing Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND 1 AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING O R OR AUTHORIZED AGENT: Signature: nn,{ e-tui 1}3'zL -- �"N Print Name: - etuwr - tn Mailing Address: 15 - to ' - le l I Date Application Accepted: Q: MppliatimeWame- Appliatiau On IiaU -2106 - Penult Appl iatimdec Revised: 9-2006 lb Date: 1- 19 - D(o Day Telephone: l`{fr r91Fr 7M(0le \nk 4pml it l y C 3 ►M( - IQs State Zip Date Application Expires: Staff Initials: 1 Page 6 of 6 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Fax: 206 -431 -3665 Web site: http: //www.cttukwila.wa.us RECEIPT Parcel No.: 2623049023 Permit Number: D06 -464 Address: 1068 SOUTBCENTER MALL TUKW Status: ISSUED Suite No: Applied Date: 12/14/2006 Applicant: GAMESTOP Issue Date: 01/18/2007 Receipt No.: R07 -00108 Initials: JEM Payment Date: 01/25/2007 02:34 PM User ID: 1165 Balance: 50.00 Payee: RAY STEWART TRANSACTION LIST: Type Method Description Amount Payment Cash 58.00 ACCOUNT ITEM LIST: Description PLAN CHECK - NONRES Account Code Current Pmts 000/345.830 58.00 Total: $58.00 Payment Amount: 558.00 2 01/25 9716 TOTAL. 58.00 rine• RRrnint -OR Printed. 01- 25.2007 Parcel No.: 2623049023 Permit Number: D06 -464 Address: 1068 SOUTHCENTER MALL TUHW Status: APPROVED Suite No: Applied Date: 12/14/2006 Applicant: GAMESTOP Issue Date: Receipt No.: R07 -00076 Payment Amount: 5502.00 Initials: JEM Payment Date: 01/18/2007 12:20 PM User ID: 1165 Balance: 50.00 Payee: L & L RETAIL CONSTRUCTION, LLC TRANSACTION LIST: Type Method Description Amount Payment Check 2623 502.00 ACCOUNT ITEM LIST: Description BUILDING - NONRES STATE BUILDING SURCHARGE City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.cttukwila.wa.us RECEIPT Account Code Current Pmts 000/322.100 497.50 000/386.904 4.50 Total: $502.00 3857 01/18 9716 TOTAL 502.00 dnr.• Rernint -OR Printed- 01.18 -7007 RECEIPT NO: R06 -01962 Initials: User ID: Doc: RECSEIS - 06 JEM 1185 SET TRANSACTIONS: Set Member Amount ACCOUNT ITEM LIST: Description PLAN CHECK - NONRES City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us Payee: PRECISION PERMIT SERVICE D06 -464 I 323.38 M06 -281 45.61 TOTAL: 368.99 SET RECEIPT TRANSACTION LIST: Type Method Description Amount Payment Check 3891 - 368.99 TOTAL: 368.99 Account Code Current Pmts Payment Date: 12/14/2005 Total Payment: 368.99 SET ID: S000000654 SET NAME: Tmp set/Initialized Activities 000/345.830 368.99 TOTAL: 368.99 Project: G/9/27F _11 Type of Inspection: F Address: /o/),) 5))//44 Date Called: Special Instructions: Date Wanted: c ,2 -- / - C o 7 Requester: Phone No: (0/9 ' ,riZ - r tee 7 3 M Approved per applicable codes. INSPECTION RECORD Retain a copy with permit INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 ' Corrections required prior to approval. COMMENTS: 17 $58.00 REINSPECTION FE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to sechedule reinspection. Receipt No.: Date: Project: 4pn /4) A % /-t/, - Type of Inspection: A.c ini/m/6 Address: 3.3/y 5 / /Gs/ Date Called: Special Instructions: Date Wanted: i - ca 4—:: P.m. Requester: Phone No: a ct 4 - S/ O - is35 0 Approved per applicable codes. INSPECTION RECORD Retain a copy with permit INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 El Corrections required prior to approval. COMMENTS: / G✓o �� r " 3 ()I-3-41# r $58.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must 5e paid at 6300 Southcenter Blvd., Suite 100. Call to sechedule reinspection. Receipt No.: Date: Project: t: L bh1 Y'� Type o ' %!/, x..? 17/ Address: ' �t�t g ct nit 1,j// Date Called: Special Instructions: t Date Wanted: /---2..-07 -O7 P.m. Requester: Phone No: _ C.C /a1 Z INSPECTION RECORD Retain a copy with permit INSPECTION NO. CITY QF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3 Approved per applicable codes. El Corrections required prior to approval. I i ArLI 41 1 S58. r i • EINSPECTION E REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to sechedule reinspection. Receipt No.: Date: INSPECTION RECORD Retain a copy with permit 0 INSPECTION NO. PER CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 206)431 -367f Project: Type of I�ection: GfJmE,SIayJ I f— ,�fJrrli�✓ I Address: Date Called: Special Instructions: Date Wanted: Z S O'> m. Requester: Phone No_ I Approved per applicable codes. �uli Melons required prior to approval. COMMENTS: Inspec r�� IDase_ 2 5 d r 00 REINSPECTION FEE EQUIRED,lrior to inspection, fee must be id at 6300 Southcenter Blvd., Suit 100. Call to sechedule reinspection. I Receipt No.: IDate: .2YECfa3Se a:exerYiuYbn_, •t:^ n.... a Project: G Aw c STC p Type of Inspection: i 1 II - ,-,,t Address: 1 to S C . MALL Suite #: Contact Person: Special Instructions: Phone No.: Needs Shift Inspection: Sprinklers: Fire Alarm: Hood & Duct: Monitor: Pre -Fire: Permits: Occupancy Type: INSPECTION NUMBER 1 pproved per applicable codes. INSPECTION RECORD Retain a copy with permit CITY OF TUKWILA FIRE DEPARTMENT 70 (a - 6�1 PERMIT NUMBERS 444 Andover Park East, Tukwila, Wa. 98188 206- 575 -4407 Word /Inspection Record Form.Doc 1/13/06 Corrections required prior to approval. COMMENTS: Date: //3 // 3 Hrs.: / Inspector: il wiS t �/ n $80.00 REINSPECTION FEE REQUIRED. You will receive an invoice from 4 he City of Tukwila Finance Department. Call to schedule a reinspection. T.F.D. Form F.P. 113 Project Info Project Address GA6u9ToF Date 12/1/2006 1068 909TH CENTER -SPACE 400 For Building Department Use FILE Copy • TOENILA, WASHINGTON 98188 Applicant Name: FRED GOGLIA Applicant Address: 1950 CRAIG RD. SUITS 300, ST. LOUIS, NO 63146 Applicant Phone: (314) 415-2400 .. ,, r Project Description ❑ New Building ❑ Addition ] Alteration Indicate controls (Sections 1513) includ(ng commissioning 1.50 51 Plans Included . , requirements on plans. Compliance Option 0 Prescriptive Q Lighting Power Alldvrance (See Qualification Checklist (over). Indicate Prescriptive & LPA 0 Systems Analysis spaces clearly on plans.) Alteration Exceptions (check appropriate box - sec. 1132.3) 639.0 • No changes are being made to the lighting • Less than 80% of the fixtures new, installed wattage not Increased, & space use not changed. Location Fixture Description Number of Fixtures Watts/ Fixture Watts Proposed RETAIL RETAIL 1.50 1000.0 ,1500.0 RETAIL RETAIL DISPLAY FOOTNOTE 810 1.50 MI e a b D UM LTG 9 Location (floor /room no.) Occupancy Description Allowed Watt per ft •• Area in ft Allowed x Area RETAIL RETAIL 1.50 1000.0 ,1500.0 RETAIL RETAIL DISPLAY FOOTNOTE 810 1.50 1000.0 1500.0 D UM LTG 9 71.0 639.0 — From From Table 15-1 (over) - document all exceptions on form LTG -LPA Total Allowed Watts 3000.0 Location (floor/room no.) Fixture Description Number of - Fixtures Watts/ Fixture Watts Proposed A 212 LTG 18 69.0 1242.0 c 2E4 LTG 3 62.0 386.0 D UM LTG 9 71.0 639.0 F DONN LTG 11 75.0 825.0 E LIGHT YAW COMBO 1 75.0 75.0 C � Total Proposed Watts may not exceed Total Allowed Watts for Interior Total Proposed Watts 2967.0 Location CQgQMPLIANCE Mowed Watts per ft or per If Area in tl (or If for perimeter) Allowed Watts x fe (or x If) Covered Parking (standard paint) _ . $ tnlnn irf ( � 0.2 W/ft Covered Parking (reflective paint) utu 2 8 2008 0.3 W/It - �� RE I+ BiIED FTUKWIL# Open Parking 0.2 W� UTY Outdoor Areas ( � �ik DIVT JON R2 0.2 W/fl 0.25 / C � EC 14 ?006 I�+EN� iTt/6- tY1G1'1 Bldg. (by facade)' Bldg. (by penm) BUILDING - - ._ 7.5 W /If 1. Choose either the facade area or the perimeter method, but not both) Total Allowed Watts 2004 Washington State Nonresidential Energy Code Compliance Pomp 2004 Washington State Nonresidential Energy Code Compliance Form Lighting Summary LTG -SUM Maximum Allowed Lighting Wattage (Interior Proposed Lighting Wattage (Interior Maximum Allowed Light)ng 4tk()¢r ) Revised May2005 Notes: 1. Use manufacturer's listed maximum input wattage. For hard -wi ed ballasts only, the default table in the NREC Technical Reference Manual may also be used 2. Include exit lights unless less than 5 watts per fixture. 3. List all fixtures. For exempt lighting, not exception and leave Watts /Fixture blank. Use m listed maximum input wattage. For Oxr wim hard - it a oar iy, Proposed Lighting Wattage (Exterior) the default table in the NREC Technical Reference Manual may also be used. 77'tS5)C Use' LPA` (W /sf) Use' LPA` (Wlsf) Painting, welding, carpentry, machine shops 2.3 Office buildings, office/administrative areas in facilities of other use, types (including but not limited to schools, hospitals, institutions, museums, banks, churches) r 1.0 Barber shops, beauty shops 2.0 Police and fire stations 1.0 Hotel banquet/conference /exhibition hal'' 2.0 Atria (atriums) 1.0 Laboratories 1.8 Assembly spaces", auditoriums, gymnasia ° , heaters 1.0 Aircraft repair hangars 1.5 Group R -1 common areas 1.0 Cafeterias, fast food establishments 1.5 Process plants 1.0 Factories, workshops, handling 1,5 Restaurants/bars' 1.0 Gas stations, auto repair shops 1.5 Locker and/or shower facilities 0.8 Institutions 1,5 Warehouses ", storage areas 0.5 Libraries' 1.5 Aircraft storage hangars 0.4 Nursing homes and hotel/motel guest rooms 1.5 Retail' ° , retail banking 1.5 Wholesale stores (pallet rack shelving) 1.5 Parking garages (see exterior lighting) Section 1532 Mall concourses 1.4 Schools buildings (Group E occupancy only), school classrooms, day care centers 1.35 Plans Submitted for Common Areas Only' Laundries 1.2 Main floor building lobbies' (except mall concourses) 1.2 Medical Offices, Clinics" 1.2 Common areas, corridors, toilet facilities and washrooms, elevator lobbies 0.8 Prescriptive Spaces Occupancy: 0 Warehouses, storage areas or aircraft storage hangers QOther Qualification Checklist Note: If occupancy type Is "Other and fixture answer is checked, the number of fixtures M the space is not limited by Code. Clearly indicate these spaces on plans. It not qualified, do LPA Calculations. Lighting Fixtures: (Section 1521) Check if all fixtures are ballasted and at least 95 %" of fixtures are either: 1. Fluorescent fixtures which a) are non - lensed. b) have 1 or 2 two lamps c) have 5-60 watt T -1, T -2, T-4, T -5, T-8, T-8 lamps. d) have hard -wired electronic dimming ballasts. Screw -in compact fluorescent fixtures do not qualify. 2. Metal Halide with a) reflector b) ceramic MH lamps <= 150w c) electronic ballasts • - Exit and LEO lights can be excluded from count if < 5 watts/fixture. Lighting Summary (back) LTG -SUM 2004 Weshlrpton State Nonresidential Energy Code Compliance Forms 2004 Washington State Nonresidential Energy Code Compliance Form Revised May 2005 TABLE 15 -1 Unit Lig hting Power Allowance (LPA Footnotes for Table 15-1 1) In cases in which a general use and a specific use are listed. the specific use shall apply. In cases in which a use is not mentioned specifically, the Unit Power Allowance shall be determined by the building official. This determination shall be based upon the most comparable use specified In the table. See Section 1512 for exempt areas. 2) The watts per square foot may be increased, by two percent per foot of ceiling height above twenty feet. unless specifically directed otherwise by subsequent footnotes. 3) Watts per square foot of room may be increased by two percent per foot of ceiling height above twelve feet. 4) For all other spaces, such as seating and common areas, use the Unit Light Power Allowance for assembly. 5) Watts per square foot of room may be increased by two percent per foot of ceiling height above nine feet. 6) See Section 1532 for exterior lighting. 7) For conference rooms and offices less than 150ft' with full height partitions, a Unit Lighting Power Allowance of 1.20 w/ft may be used. 8) For the fire engine room, the Unit Lighting Power Allowance Is 1.0 watts per square foot. 9) For Indoor sport toumament courts with adjacent spectator seating, the Unit Lighting Power Allowance for the court area is 2.6 watts per square foot. 10) Display window illumination installed within 2 feet of the window, provided that the display window is separated from the retail space by walls or at least three- quarter - height partitions (transparent or opaque). and lighting for free- standing display where the lighting moves with the display are exempt. An additional 1.5 w/f9 of merchandise display luminaires are exempt provided that they comply with all three of the following: a) located on ceiling- mounted track or directly on or recessed Into the ceiling itself (not on the wall). b) adjustable In both the horizontal and vertical axes (vertical axis only is acceptable for fluorescent and other fixtures with two points of track attachment). c) fitted with LED, tungsten halogen, fluorescent, or high intensity discharge lamps. This additional lighting power Is allowed only if the lighting is actually installed. 11) Provided that a floor plan, indicating rack location and height, is submitted. the square footage for a warehouse may be defined, for computing the interior Unit Lighting Power Allowance, as the floor area not covered by racks plus the vertical face area (access side only) of the racks. The height allowance defined In footnote 2 applies only to the floor area not covered by racks. 12) Medical and clinical offices include those facilities which, although not providing ovemight patient care, do provide medical, dental, or psychological examination and treatment. These spaces include, but are not limited to , laboratories and treatment centers. Lighting Permit Plans Checklist LTG -CHK 2004 Washington State Nonresidential Energy Code Compliance Forms Revised May 2005 Project Address - ougSTOP 'Date 12/1/2006 The following information is necessary to check a lighting permit application for compliance with the lighting requirements in the 2004 Washington State Nonresidential Energy Code. Applicability (yes, no, n.a.) Code Section Component Information Required Location on Plans Building Department Notes LIGHTING CONTROLS (Section 1513 yes 1513.1 Local control /access Schedule with type, indicate locations E2 yes 1513.2 Area controls Maximum limit per switch - E2 n.a. 1513.3 Daylight zone control Schedule with type and features, indicate locations n.a. vertical glazing Indicate vertical glazing on plans n. a. overhead glazing Indicate overhead glazing on plans yes 1513.4 Display /exhib/special Indicate separate controls E2 1513.5 Exterior shut-off Schedule with type and features, indicate location n, a. (a) timer w /backup Indicate location n.a. (b) photocell. Indicate location 1513.6 Inter. auto shut-off Indicate location n. a. 1513.6.1 (a) occup. sensors Schedule with type and locations n. a. 1513.6.2 (b) auto. switches Schedule with type and features (back -up, override capability) Indicate size of zone on plans n.a. 1513.7 Commissioning Indicate requirements for lighting controls commissioning yes Lighting Sum. Form Completed and attached. Schedule with fixture types, lamps, ballasts, watts per fixture E2 a. a. 1437 Elec motor efficiency MECH -MOT or Equipment Schedule with hp, rpm, efficiency 2004 Washington State Nonresidential Energy Code Compliance Form If "no" Is circled for any question, provide explanation: Lighting Permit Plans Checklist rw Rn rl 2004 Washin •ton State Nonresidential Ene Lighting - General Req uirements in a tiohti51 , sha co. ly with this . Where occupancy o c up a nc 1512, shall comply cited, they shall have the features occupancy sensors are cited, listed t in h they Section 1513.6.1. ve the fea listed In Section 1513.6 2. cited, tey wails or ceiling-height partitions, shall be provided 1513.1 Local Control and Accessibility: Each space, enclosed by controls located within that space. The fighting controls, whether one or more, with righting shall be c a p able of taming off all l within the The o exit, t personnel o reoccupying or s shall be accessible, ble, at the point oint o of entry /exit, the space. EXCEPTIONS: The following lighting controls may be centralized In remote locations: 1 Lighting orttrols for spaces which must be used as h 2. Automatic controls. operators. 3. Controls requiting rdo and security. 4. Controls for safety haze aids power that may controlled Area Controls: Tee wax, Ito ere circuit controlled from a sir switch or automatic twenty amp cir shall not exceed that o Is provided by by rcent. A master control may loaded to not t more than eighty pa be installed t o son independently. me individual ndenUYe Circuit breakers may not be used capability 0 sole be used 11h of switching. EXCEPTIONS: 1. Industrial or manufacturing process areas, as 2. may Areas less 11101 five percent of footprint for footprints over 100,000 square feet. 1513.3 light defined Day Chapter . both under overhead glaz ng and as adjacent o r d -or occupant-sensing automatic controls, controls, or caul 9 independent of general area lighting. which control the tights t zopa adj Contiguous daylight w zones ing eacontroitin device provided dye allowed to be o incli by more than two adjacent that anal orientations not include (i.e. north, r easg west). Daylight zones l der overhead d gla mo east, south, 15 feet from thees zoost rsr shall b cons perimeter shall be controlled separately from daylight adjacent to vertical glazing. EXCEPTION: cgs enclosed walls or Calling De eater. Daylight spa d b r 1 ht whichever is g hetu t aretio not eq t h 2 s fewe switch for 1513.7 Commissioning Requirements: r lighting t controls, controls r s coaing general ere not hung. which include daylight or occupant required to have a sap _ genera Erea bighting. a utomatic shutoff controls, occupancy sensors, or automatic Exhibition, exhibition, and Specialty Lighting controls shell be tested ed systems era 1o13.4 ed inlay, or area lighting shall be time switches, the S, lighting on ents. equipment with s ar general area lightln9. that control devices, w P 3 operate in accordance 1513. A All .tic Shut-Off t f i Co calibrated, not t Intended Oor co nt in onus use hal be alibrated, adjusted and o ans an d sp ecifications. Sequences of operation a o h be 1513.5 Automatic switched by to ensure they operate ate report 6 test lighting switc or a combination of functionally e plans a specifications. A comp) not Intended for 24 -hour continuous use shall e o mat1ca11Y switched by timer, photocell, ti c Um0 switches must also have p rocedures and results shall a prepared an filed w ith the Sur timer and photocell. oc h t ics, which prevent the loss o program back -UP saps program and time settings for at least 10 hours, if power is Interrupted. 4. Hospitals and laboratory spaces. 5. Areas performed are exempt t from theeoccupancy which sensor requirement. 1513.6.1 Occupancy Sensors: O ag light se sn tS hall bee capable of automatically turning off more than 30 minutes after the area shall have a vacated. Light fixtures controlled ual switch capable of turning off lights when Me e mounted, d, Code Compliance Form greater Autom0 Shut an d ati school be erecter than h separate automatic controls to shut off the lig hting d during sno ied hours. Within these buildings, all lighting during s than 300 walls or ceiling_ office p ass less than a e e tin an by all school of c and alt s meeting d with occupancy and conference rooms, all sensors ool classrooms, shall be equipped Ume switch, automatic is ct comic may be a1513.6. occ ancy sensor, s time s automatid controls of automatically shutting off lighting. or other device capable EXCEPTIONS: 1. Areas that must be continuously illuminated e.g., m4anner requiring manual operation of the ed in a 2-hour convenience stores), or lighting. lighting systems. 2. Emergency g process 3, collides for as may b e industrial or for f productti n. facilities ay 1513. is occupied. clock and be capable of being set 1513.6.2 Automatic Time Switches: Automatic time switches shall have a minimum 7 day for 7 automatic hot day t iday " shut per week e which incorporate ss all loads for automatic holiday feature, at east 24 hours and then resumes normally scheduled revent the toss of program and operations. Automatic time switches Shall also have program back-up capabilities, 0 P if wer is interrupted. Ume settings for r least ast 1 10 a, Po an over -ride Automatic time switches S shall shall switching device which: a) is readily lights accessible; a�n using the device can see We b) is h s or t e areas that a p controlled the switch, or so that the area being illuminated Is an Is an by Is manually operated; and allows the lighting to remain on for no more than two tours when an over -ride is Initiated; and controls an area not exceeding 5,000 square feet or 5 rcent of footprint for footprints over 100,000 square feet, d) e) owner. Drawing notes s accordance with this Paragraph. Mechanical - Complex Systems Checklist MECH -COMP 2004 Washington Stale Nonresidential Energy Code Compliance Forms Revised May 2005 Project Address Camaco? e Date 12/4/2006 The following additional information is necessary to check a mechanical permit application for a complex mechanical system for compliance with the mechanical requirements in the Washington State Nonresidential Energy Code. Use the checklist as a reference for notes added to the mechanical drawings (see the MECH- CHK checklist for additional system requirements). This information must be on the plans since this is the official record of the permit. Having this information in separate specifications alone is NOT an acceptably.,,,,.„ alternative. For Building Department Use �rG FILE COPY , r ` -�• , _ _ Applicability (yes, no, n.a.) Code Section Component • Information Required Location on Plans Building Departmen Notes . . ADDITIONAL CHECKLIST ITEMS FOR COMPLEX SYSTEMS ONLY 1431.1 Field assem. sys. Provide calculations 1432.1 Setback & shut -off Indicate separate systems or show isolation devices on plans 1432.2.1 Air system reset Indicate automatic reset - .... , 1432.2.2 Hydr. system reset Indicate automatic reset 1433 Air Economizer Indicate economizer on equipment schedule or provide calculations to justify exemption and demonstrate 10% higher efficiency for equipment with out economizer. 1433 Water Economizer Indicate water economizer and provide calculations if 1433 Exception 2 is utilized CO/pp r J_ W _� / 1434 Separate air sys. Indicate separate systems on plans 1 � r FQ{� LIAIVC, 1435 Simul. htg. & clg. Indicate that simultaneous heating and cooling is prohibited, unless use of exception is justified 1 t firm , �^1t- 1436 Heat recovery Indicate heat recovery on plans; complete and attach heat recovery calculations JEC I 11(Ib 1437 Elec. motor effic. MECH -MOT or Equip. Schedule with hp, rpm, efficiency 1438 Variable flow sys. Indicate variable flow on fan and pump schedules Cf CI yjla 1439.1 KRChen Hoods Indicate uncooled and unheated make -up air RU J LD Nr n 1 ��� 1439 Fume Hoods Indicate VAV, unheated / uncooled or heat rec. makeup no 1s circled for any question, provide explanation: Decision Flowchart Use this flowchart to determine how the requirements of the Complex Systems Option apply to the project. Refer to the indicated Code sections for more complete information on the requirements. Start Here • Section 1411.1 Equipmen Efficiency Shall Meet Tables 14 -1A through 14-1G Section 1432.2.1 Supply Jr A Reset Controls Required Yes 3 1411,1 Intermittent Ignition Device & Power Venting or Damper, 0.75% Maximum Jacket Loss 1412.6 Modulating or Staged Combustion Controls Required 2004 Washing ton State Nonresidential Energy Code Compliance Form Yes 3 Section 1431.1 Calculations of Total On-Site Energy Input 8 Ouput Required (continued on back) RECEIVED CINn TUKWIIA DEt; 14 2006 ITCENTER Yes No Section 1432.2.2 Hot Water Supply Temperature Reset Required pot, 404 Mechanical - Complex Systems (back) MECH -COMP Revised May 2005 2004 Washington State Nonresidential Energy Code Compliance Forms 1 0% Air Econ Provided? Section 1413 Water Cooled wMater Econo? Yes Total Clg Capacity w/ Water Econo 500 Tons Yes pply Air >5, cfm & OSA > 70% otor Incl.l qpmt. Covr'd by Tbl 14- 1A -14- 1G? EER 10% Better than Code tal Cap. cono <= 480,00 Btuh or 20% of otal Cap. Section 1436 50% Effective Heat Recovery Required Multi -speed Motor in Mufti - system? Yes 2004 Washington State Nonresidential Energy Code Compliance Form Yes No 0 DONE Section 1435 Zone Controls Must Reduce Supply Air Quantity Before Reheating/Recooling o No Section 1439.1 No Heating or Cooling for at Least 50% of Make -up Air 0 No-* Section 1433 Air-Side Economizer Required Yes Section 1437 Motors Must Meet Efficiencies in Table 14-4 stem or Zon w/ Simultaneous Htg. & Clg.? Section 1438 Variable Flow Devices Required Section 1439.2 One Required: a. 50% VAV Exhaust & Make -up b. 75% Direct Makeup w/ Tempering Only c. Heat Recovery per 1436 d. Constant Volume w/ < 50fpm Face Velocity Yes Mechanical Permit Plans 2004 Washington State Nonresidential Energy Code Compliance Checklist MECH -CHK Forms Revised May 2005 Project Address oaaescop (Date 12/4/2006 The following information is necessary to check a mechanical permit application for compliance with the mechanical requirements in the Washington State Nonresidential Energy Code. Applicability (yes, no, n.a.) Code Section I Component I Information Required I Location on Plans I Building Department Notes HVAC REQUIREMENTS (Sections 1401 -1424) 1411 Equipment performance yes 1411.4 Pkg. elec. htg.& clg. List heat pumps on schedule en. yes 1411.1 Minimum efficiency Equipment schedule with type, capacity, efficiency Nt o.+. 1411.1 Combustion htg. Indicate intermittent ignition, flue /draft damper & jacket loss 1412 HVAC controls yes 1412.1 Temperature zones Indicate locations on plans M1 /N2 yes 1412.2 Deadband control Indicate 5 degree deadband minimum M2 o. a. 1412.3 Humidity control Indicate humidistat yes 1412.4 Automatic setback Indicate thermostat with night setback and 7 diff. day types 142 yes 1412.4.1 Dampers Indicate damper location and auto. controls & max. leakage 1422 a. a. 1412.4.2 Optimum Start Indicate optimum start controls yes 1412.5 Heat pump control Indicate microprocessor on thermostat schedule M1 0.a. 1412.6 Combustion htg. Indicate modulating or staged control yes 1412.7 Balancing Indicate balancing features on plans 122 yes 1422 Thermostat interlock Indicate thermostat interlock on plans 142 o. s. 1423 Economizers Equipment schedule 1413 Air economizers o.a. 1413.1 Air Econo Operation Indicate 100% capability on schedule n.a. 1413.1 Wtr Econo Operation Indicate 100% capacity at 45 degF db & 40 deg F wb n.a. 1413.2 Water Econo Doc Indicate dg load & water e:wnoe & clg tower performance a. s. 1413.3 Integrated operation Indicate capability for partial cooling no 1413.4 Humidification Indicate direct evap or fog atomization w/ air economizer 1414 Ducting systems yes 1414.1 Duct sealing Indicate sealing necessary 112 yes 1414.2 Duct insulation Indicate R -value of insulation on duct 111/112 yes 1415.1 Piping insulation Indicate R -value of insulation on piping 122 1416 Completion Requirements yes 1416.182 Drawings & Manuals Indicate requirement for record drawings and operation does N2 yell 1416.3.2 Air Balancing Indicate air system balance requirements 112 o.a. 1416.3.3 Hydronic Balancing Indicate hydronic system balance requirements yes 1416.4 Commissioning Indicate requirements for commissioning and prelim. Report 111 a. a. 1424 Separate air sys. Indicate separate systems on plans yes I (Mechanical summary Forrn Completed and attached. Equipment schedule with types, input/output, efficiency, afro, hp, economizer SERVICE WA ER HEATING AND HEATED POOLS (Sections 1440 -1454) 1440 Service water Mg. yes 1441 Elec. water heater Indicate R -10 insulation under tank N2 yes 1442 Shut -off controls Indicate automatic shut-off 112 yes 1443 Pipe Insulation Indicate R -value of insulation on piping 112 n. a. 1452 Heat Pump COP Indicate minimum COP of 4.0 a. et. 1452 Heater Efficiency Indicate pool heater efficiency n.a. 1453 Pool heater controls Indicate switch and 65 degree control n. a. 1454 Pool covers Indicate vapor retardant cover a. a. 1454 Pools 90+ degrees Indicate R -12 pool cover 2004 Washington State Nonresidential Energy Code Compliance Form 2004 Washington State Nonresidential Energy Code Compliance Form Mechanical Permit Plans Checklist MECH -CHF( 2004 Washington State Nonresidential Energy Code Compliance Forms Revised May 2005 Mechanical - General Requirements 1411.1 General: Equipment shall have a minimum performance at the specified rating conditions not less than the values shown in Table 14 -1A through 14 -1G. If a nationally recognized certification program exists for a product covered in Tables 14 -1A through 14-10, and it includes provisions for verification and challenge of equipment efficiency ratings. then the product shall be listed In the certification program. Gas -fired and oil -fired forced air furnaces with Input ratings > 225.000 Btu /h (65 kW) shall also have an Intermittent Ignition or Interrupted device (11D ), and have either mechanical draft (including power venting) or a flue damper. A vent damper is an acceptable alternative to a flue damper for furnaces where combustion air Is drawn from the conditioned space. All furnaces with input ratings > 225,000 Btu /h (65 kW), including electric furnaces, that are not located within the conditioned space shell have jacket losses not exceeding 0.75% of the input rating. 1411.2 Rating Conditions: Cooling equipment shall be rated el ARI test conditions and procedures when available. W here no applicable procedures exist. data shall be furnished by the equipment manufacturer. 1411.3 Combination Space and Service Water Heating: For combination space and service water heaters with a principal function of providing space heat, the Combined Annual Efficiency (CAE) may be calculated by using ASHRAE Standard 124 -1991. Storage water heaters used In combination space heat and water heat applications shall have either an Energy FActor (EF) or a CAE of not lees than the following: 1411.4 Packaged Electric Heating and Cooling Equlpmen : Packaged electric equipment providing both heating and cooli g with a total cooling capacity Brea er than 20.000 Btu /h shall be a hest ump. Exception: Unstaffed equipment shaelter or cabinets used solely for personal wireless service facilities. 1412 Controls 1412.1 Tempeeeeeee Controls: Each system shall be provided with at least one temperature control device. Each zone shall be controlled by Individual thermostatic controls responding to temperature within the zone. At a minimum, each floor of a building shall be considered as a separate zone. 1412.2 Headband Controls: When used to control both comfort heating and cooling, zone thermostatic controls shall be capable of a deadband of at least 5 degrees F within which Me supply of heating and cooling energy to the zone Is shut off or reduced to a minimum. Exceptions: 1. Special occupancy, special usage, or code requirements where deadband controls are not appropriate. Buildings complying with Section 1141.4, if in the proposed building energy analysis, healing and cooling thermostat setpoints are set to the same temperature between 70 degrees F and 75 degrees F Inclusive, and assumed to be constant throughout the year. Thermostats that require manual changeover between heating and cooling modes. 1412.3 Humidity Controls: If a system Is equipped with a means for adding moisture, a humidistat shall be provided. 1412.4 Setback and Shut -Off: HVAC systems shall be equipped with automatic controls capable of accomplishing a reduction of energy use Through control setback or equipment shutdown during periods of non -use or alternate use of the spaces served by the system. The automatic controls shall have a minimum seven -day clock and be capable of being set for seven different day types per week. Exceptions: 1. Systems serving areas which require continuous operation at the same temperature setpoint. 2. Equipment with hill load demands of 2 kW (8.826 Btu /h) or less may be controlled by readily accessible manual off -hour controls. 1412.4.1 Dampen: Outside sir Intakes, exhaust outlets and relief outlets serving conditioned spaces shall be equipped with dampers which close automatically when the system Is off or upon power failure. Excaptlon•: 1. Systems serving areas which require continuous operation. 2. Combustion air intakes. 3. Gravity (nonmotorized) dampers are acceptable in buildings less than 3 stories in height. Gravity (nonmotorized) dampers are acceptable in exhaust and relief outlets in the first story and levels below the first story of buildings three or more stories In height. 1412.4.2 Optimum Start Controls: Heating and cooling systems with design supply air capacities exceeding 10,000 cfm shall have optimum start controls. Optimum start controls shall be designed to automatically adjust the start time of an HVAC system each day to bring the space to desired occupied temperature levels immediately before scheduled occupancy. The control algorithm shall, as a minimum, be a function of the difference between space temperature and occupied setpoint and the amount of time prior to scheduled occupancy. 1412.5 Heat Pump Controls: Unitary air cooled heat pumps shall Include microprocessor controls that minimize supplemental heat usage during start-up, eel -up, and defrost conditions. These controls shall anticipate need for heat and use compression heating as the first stage of heat. Controls shall indicate when supplemental healing is being used through visual means (e.g., LED indicators). 1412.6 Combustion Heating Equipment Controls: Combustion heating equipment with a capacity over 225,000 Btu /h shall have modulating or staged combustion control. Exceptions: 1. Boilers. 2. Radiant Heaters. 1412.7 Balancing: Each air supply outlet or air or wafer terminal device shall have a means for balancing, including but not limited to, dampers, temperature and pressure test connections and balancing valves. 1413 Air Economizers 1413.1 Operation: Air economizers shall be of automatically modulating outside and return air dampers to provide 100 percent of the design supply alr as outside sir to reduce or eliminate the need for mechanical cooling. Water economizers shell be capable of providing the total concurrent cooling load served by the connoted terminal equipment lacking airside economizer, at outside air temperatures of 45 ° F dry - bulb /40 ° F wet -bulb and below. For this calculation, all factors including solar and internal load shall be the same as those used for peak load calculations, except for the outside temperatures. Exception: Water economizers using air - cooled heat rejection equipment may use a 35 ° F dry -bulb outside air temperature for this calculation. This exception is limited to a maximum of 20 tons per building. 1413.2 Documentation: Water economizer plans submitted for approval shall include the following information: 1. Maximum outside air conditions for which economizer is sized to provide full cooling. Design cooling load to be provided by economizer at this outside air condition. Heal rejection and terminal equipment performance data including model number. flow rate, capacity, entering and leaving temperature in full economizer cooling mode. 1413.3 Integrated Operation: Air economizers shall be capable of providing partial cooling even when additional mechanical cooling is required to meet the remainder of the cooling load. Exceptions: 1. Individual, direct expansion units that have a rated capacity less than 85,000 Btu /h and use nonintegrated economizer controls that preclude simultaneous operation of the economizer and mechanical cooling. 2. Water-cooled water chillers with waterside economizer. 1413.4 Humidification: If an air economizer is required on a cooling system for which humidification equipment is to be provided to maintain minimum indoor humidity levels. then the humidifier shall be of the adiabatic type (direct evaporative media or fog atomization type). Excaptlons: 1. Health care facilities where WAC 248- 320 -525 allows only steam Injection humidifiers in ductwork downstream of final filters. 1412.6 Combustion Healing Equipment Controls: Combustion heating equipment with a capacity over 225.000 Btu /h shall have modulating or staged combustion control. 2. Systems with water economizer 3. 700% outside air systems with no provisions for air recirculation to the central supply fan. Nonadiabatic humidifiers cumulatively serving no more than 10% of a building's air economizer capacity as measured in cfm. This refers to the system cfm serving rooms with stand alone or duct mounted humidifiers. 1414 Ducting Systems 1414.1 Sealing: Duct work which is designed to operate at pressures above 1/2 inch water column static pressure shall be sealed in accordance with Standard RS -18. Extent of sealing required is as follows: 1. Static pressure: 1/2 inch to 2 inches; seal transverse joints. 2. Static pressure: 2 Inches to 3 inches: seal all transverse joints and longitudinal seams. 3. Static pressure: above 3 inches; seal all transverse joints, longitudinal seams and duct wall penetrations. Duct tape and other pressure sensitive tape shall not be used as the primary sealant where ducts are designed to operate at static pressures of 1 inch W.C. or greaser. 1414.2 Insulation: Ducts and plenums that are constructed and function as part of the building envelope. by separating interior space from exterior space, shall meet all applicable requirements of Chapter 13. These requirements include insulation installation. moisture control, air leakage, and building envelope insulation levels. Unheated equipment rooms with combustion air louvers must be Isolated from the conditioned apace by Insulating interior surfaces to a minimum of R -11 and any exterior envelope surfaces per Chapter 13. Outside air ducts serving individual supply air units with Isas than 2,800 cfm of total supply air capacity shall be Insulated to • minimum of R -7 and are not considered building envelope. Other outside air duct runs are considered building envelope until they, 1. connect to the heating or cooling equipment, or 2. are isolated from the exterior with an automatic shutoff damper complying with Section 1412.4.1. Once outside air ducts meet the above listed requirements, any rune within conditioned space shall comply with Table 14 -5 requirements. Other dude and plenums shall be thermally insulated per Table 14 -5. Exception•: 1. Within the HVAC equipment. 2. Exhaust air ducts not subject to condensation. 3. Exposed ductwork within a zone that serves that zone. 1415 Piping Systems 1415.1 Insulation: Piping shall be thermally insulated in accordance with Table 14 -6. Exception: Piping installed within unitary HVAC equipment. Water pipes outside the conditioned space shall be insulated in accordance with Washington State Plumbing Code (WAC 51 -26) 1416 Completion Requirements (Refer to NREC Section 1416 end the Building Commissioning Guidelines, published by the Building Commissioning Association, for complete text and guide lines for building completion and commissioning requirements.) EF CAE < 50 gal storage 0.58 0.71 50 to 70 gal storage 0.57 0.71 > 70 gal storage 0.55 0.70 2004 Washington State Nonresidential Energy Code Compliance Form Mechanical Permit Plans Checklist MECH -CHF( 2004 Washington State Nonresidential Energy Code Compliance Forms Revised May 2005 Mechanical - General Requirements 1411.1 General: Equipment shall have a minimum performance at the specified rating conditions not less than the values shown in Table 14 -1A through 14 -1G. If a nationally recognized certification program exists for a product covered in Tables 14 -1A through 14-10, and it includes provisions for verification and challenge of equipment efficiency ratings. then the product shall be listed In the certification program. Gas -fired and oil -fired forced air furnaces with Input ratings > 225.000 Btu /h (65 kW) shall also have an Intermittent Ignition or Interrupted device (11D ), and have either mechanical draft (including power venting) or a flue damper. A vent damper is an acceptable alternative to a flue damper for furnaces where combustion air Is drawn from the conditioned space. All furnaces with input ratings > 225,000 Btu /h (65 kW), including electric furnaces, that are not located within the conditioned space shell have jacket losses not exceeding 0.75% of the input rating. 1411.2 Rating Conditions: Cooling equipment shall be rated el ARI test conditions and procedures when available. W here no applicable procedures exist. data shall be furnished by the equipment manufacturer. 1411.3 Combination Space and Service Water Heating: For combination space and service water heaters with a principal function of providing space heat, the Combined Annual Efficiency (CAE) may be calculated by using ASHRAE Standard 124 -1991. Storage water heaters used In combination space heat and water heat applications shall have either an Energy FActor (EF) or a CAE of not lees than the following: 1411.4 Packaged Electric Heating and Cooling Equlpmen : Packaged electric equipment providing both heating and cooli g with a total cooling capacity Brea er than 20.000 Btu /h shall be a hest ump. Exception: Unstaffed equipment shaelter or cabinets used solely for personal wireless service facilities. 1412 Controls 1412.1 Tempeeeeeee Controls: Each system shall be provided with at least one temperature control device. Each zone shall be controlled by Individual thermostatic controls responding to temperature within the zone. At a minimum, each floor of a building shall be considered as a separate zone. 1412.2 Headband Controls: When used to control both comfort heating and cooling, zone thermostatic controls shall be capable of a deadband of at least 5 degrees F within which Me supply of heating and cooling energy to the zone Is shut off or reduced to a minimum. Exceptions: 1. Special occupancy, special usage, or code requirements where deadband controls are not appropriate. Buildings complying with Section 1141.4, if in the proposed building energy analysis, healing and cooling thermostat setpoints are set to the same temperature between 70 degrees F and 75 degrees F Inclusive, and assumed to be constant throughout the year. Thermostats that require manual changeover between heating and cooling modes. 1412.3 Humidity Controls: If a system Is equipped with a means for adding moisture, a humidistat shall be provided. 1412.4 Setback and Shut -Off: HVAC systems shall be equipped with automatic controls capable of accomplishing a reduction of energy use Through control setback or equipment shutdown during periods of non -use or alternate use of the spaces served by the system. The automatic controls shall have a minimum seven -day clock and be capable of being set for seven different day types per week. Exceptions: 1. Systems serving areas which require continuous operation at the same temperature setpoint. 2. Equipment with hill load demands of 2 kW (8.826 Btu /h) or less may be controlled by readily accessible manual off -hour controls. 1412.4.1 Dampen: Outside sir Intakes, exhaust outlets and relief outlets serving conditioned spaces shall be equipped with dampers which close automatically when the system Is off or upon power failure. Excaptlon•: 1. Systems serving areas which require continuous operation. 2. Combustion air intakes. 3. Gravity (nonmotorized) dampers are acceptable in buildings less than 3 stories in height. Gravity (nonmotorized) dampers are acceptable in exhaust and relief outlets in the first story and levels below the first story of buildings three or more stories In height. 1412.4.2 Optimum Start Controls: Heating and cooling systems with design supply air capacities exceeding 10,000 cfm shall have optimum start controls. Optimum start controls shall be designed to automatically adjust the start time of an HVAC system each day to bring the space to desired occupied temperature levels immediately before scheduled occupancy. The control algorithm shall, as a minimum, be a function of the difference between space temperature and occupied setpoint and the amount of time prior to scheduled occupancy. 1412.5 Heat Pump Controls: Unitary air cooled heat pumps shall Include microprocessor controls that minimize supplemental heat usage during start-up, eel -up, and defrost conditions. These controls shall anticipate need for heat and use compression heating as the first stage of heat. Controls shall indicate when supplemental healing is being used through visual means (e.g., LED indicators). 1412.6 Combustion Heating Equipment Controls: Combustion heating equipment with a capacity over 225,000 Btu /h shall have modulating or staged combustion control. Exceptions: 1. Boilers. 2. Radiant Heaters. 1412.7 Balancing: Each air supply outlet or air or wafer terminal device shall have a means for balancing, including but not limited to, dampers, temperature and pressure test connections and balancing valves. 1413 Air Economizers 1413.1 Operation: Air economizers shall be of automatically modulating outside and return air dampers to provide 100 percent of the design supply alr as outside sir to reduce or eliminate the need for mechanical cooling. Water economizers shell be capable of providing the total concurrent cooling load served by the connoted terminal equipment lacking airside economizer, at outside air temperatures of 45 ° F dry - bulb /40 ° F wet -bulb and below. For this calculation, all factors including solar and internal load shall be the same as those used for peak load calculations, except for the outside temperatures. Exception: Water economizers using air - cooled heat rejection equipment may use a 35 ° F dry -bulb outside air temperature for this calculation. This exception is limited to a maximum of 20 tons per building. 1413.2 Documentation: Water economizer plans submitted for approval shall include the following information: 1. Maximum outside air conditions for which economizer is sized to provide full cooling. Design cooling load to be provided by economizer at this outside air condition. Heal rejection and terminal equipment performance data including model number. flow rate, capacity, entering and leaving temperature in full economizer cooling mode. 1413.3 Integrated Operation: Air economizers shall be capable of providing partial cooling even when additional mechanical cooling is required to meet the remainder of the cooling load. Exceptions: 1. Individual, direct expansion units that have a rated capacity less than 85,000 Btu /h and use nonintegrated economizer controls that preclude simultaneous operation of the economizer and mechanical cooling. 2. Water-cooled water chillers with waterside economizer. 1413.4 Humidification: If an air economizer is required on a cooling system for which humidification equipment is to be provided to maintain minimum indoor humidity levels. then the humidifier shall be of the adiabatic type (direct evaporative media or fog atomization type). Excaptlons: 1. Health care facilities where WAC 248- 320 -525 allows only steam Injection humidifiers in ductwork downstream of final filters. 1412.6 Combustion Healing Equipment Controls: Combustion heating equipment with a capacity over 225.000 Btu /h shall have modulating or staged combustion control. 2. Systems with water economizer 3. 700% outside air systems with no provisions for air recirculation to the central supply fan. Nonadiabatic humidifiers cumulatively serving no more than 10% of a building's air economizer capacity as measured in cfm. This refers to the system cfm serving rooms with stand alone or duct mounted humidifiers. 1414 Ducting Systems 1414.1 Sealing: Duct work which is designed to operate at pressures above 1/2 inch water column static pressure shall be sealed in accordance with Standard RS -18. Extent of sealing required is as follows: 1. Static pressure: 1/2 inch to 2 inches; seal transverse joints. 2. Static pressure: 2 Inches to 3 inches: seal all transverse joints and longitudinal seams. 3. Static pressure: above 3 inches; seal all transverse joints, longitudinal seams and duct wall penetrations. Duct tape and other pressure sensitive tape shall not be used as the primary sealant where ducts are designed to operate at static pressures of 1 inch W.C. or greaser. 1414.2 Insulation: Ducts and plenums that are constructed and function as part of the building envelope. by separating interior space from exterior space, shall meet all applicable requirements of Chapter 13. These requirements include insulation installation. moisture control, air leakage, and building envelope insulation levels. Unheated equipment rooms with combustion air louvers must be Isolated from the conditioned apace by Insulating interior surfaces to a minimum of R -11 and any exterior envelope surfaces per Chapter 13. Outside air ducts serving individual supply air units with Isas than 2,800 cfm of total supply air capacity shall be Insulated to • minimum of R -7 and are not considered building envelope. Other outside air duct runs are considered building envelope until they, 1. connect to the heating or cooling equipment, or 2. are isolated from the exterior with an automatic shutoff damper complying with Section 1412.4.1. Once outside air ducts meet the above listed requirements, any rune within conditioned space shall comply with Table 14 -5 requirements. Other dude and plenums shall be thermally insulated per Table 14 -5. Exception•: 1. Within the HVAC equipment. 2. Exhaust air ducts not subject to condensation. 3. Exposed ductwork within a zone that serves that zone. 1415 Piping Systems 1415.1 Insulation: Piping shall be thermally insulated in accordance with Table 14 -6. Exception: Piping installed within unitary HVAC equipment. Water pipes outside the conditioned space shall be insulated in accordance with Washington State Plumbing Code (WAC 51 -26) 1416 Completion Requirements (Refer to NREC Section 1416 end the Building Commissioning Guidelines, published by the Building Commissioning Association, for complete text and guide lines for building completion and commissioning requirements.) Equipment Schedules The following information is required to be incorporated with the mechanical equipment schedules on the plans. For projects without plans, fill in the required information below. C ameatoP Cooling Equipment Schedule Equip. ID Brand Name' Model No. Capacity Btu/h Total CFM OSA CFM or Econo? SEER or EER IPLV Location eP -1 Trans 2TWA3036A3 33200 1100 325 12.75 Roof Heating Equipment Schedule Equip. ID Brand Name' Model No.' Capacity Btu /h Total CFM OSA cfm or Econo? Input Btuh Output Btuh Efficiency 7.8 HSPF Re - 1 Trene 27WA3036A3 30800 1100 325 Fan Equipment Schedule Equip. ID Brand Name' Model No. CFM SP' HP /BHP Flow Control Location of Service PC -1 Trans TW8036P13 1100 0.50 0.33 cv Project Info Project Address C ameatoP Date 12/4/2006 Westfield Southcenter Space 400 For Building Dept. Use Tukwila, WA 98188 Applicant Name: Applicant Address: Applicant Phone: Mechanical Summary MECH -SUM 2004 Washington State Nonresidential Energ Code Compliance Forms Project Description Briefly describe mechanical system type and features. to Includes Plans 2004 Washington State Nonresidential Energy Code Compliance Form 3 ton split system heat pump Drawings must contain notes requireing compliance with commissioning requirements - Section 1416 'If available. 2 As tested according to Table 14 -1A through 14 -1G. If required. ° COP, HSPF Combustion Efficiency, or AFUE, as applicable. 5 Flow control types: variable air volume(VAV), constant volume (CV), or variable speed (VS). Revised May 2005 Compliance Option Q Simple System O Complex System O Systems Analysis (See Decision Flowchart (over) for qualifications. Use separate MECH -SUM for simple & complex systems.) Project Info Project Address Q a0eeiOp Date 12/4/2006 Westfield Southcenter Space 400 For Building Department Use Tukwila, WA 98188 Applicant Name: Applicant Address: Applicant Phone: 2004 Washington State Nonresidential Energy Code Compliance Form Project Summary PRJ -SUM 2004 Washington Stale Nonresidential Energy Code Compliance Forms Revised May 2005 2004 Washington State Nonresidential Energy Code Compliance Form Wstfie[c[ Westfield - Southcenter 633 Southcenter Seattle, WA 98188 PH (206) 444-4756 FX (208) 444 -4790 January 30, 2007 Mark Hilliard BNBuilders, Inc. 2601 Fourth Avenue, Suite 350 Seattle, WA 98121 Dear Mark, /9X7 4/Zy At this time Westfield Is not requiring a smoke duct detector or fire alarm panel for the space occupied by GameStop (Space 400) prior to occupancy. This work will be scheduled at a future date after the tenant has taken occupancy of the space and under a separate permit. Patrick Burns Director of Construction Westfield Southcenter RECEIVED -1 2007 BUILDING DEPARTMENT DEPARTMENTS: Bu in ivisio i Public Works '' PERMIT COORD COPY`- PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER: D06 -464 DATE: 01 -18 -07 PROJECT NAME: GAMESTOP SITE ADDRESS: 1068 SOUTHCENTER MALL Original Plan Submittal Response to Correction Letter # Response to Incomplete Letter # X Revision # 1 After Permit Issued Fire Prevention Structural DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete Comments: Please Route TUES/THURS ROUTING: Documents/routing slip.doc 2 -28 -02 REVIEWER'S INITIALS: APPROVAL CORRECTIONS: Incomplete ❑ Structural Review Required DATE: DATE: Planning Division ❑ Permit Coordinator No further Review Required DUE DATE: 01-23-07 Not Applicable ❑ Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: DUE DATE: 02 -20-07 Approved Approved with Conditions ❑ Not Approved (attach comments) ❑ Notation: REVIEWER'S INITIALS: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: PERMIT COORD COPY `,, PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER: D06 - 464 DATE: 12 -14 -06 PROJECT NAME: GAMESTOP SITE ADDRESS: 1068 SOUTHCENTER MALL X Original Plan Submittal Response to Correction Letter # Response to Incomplete Letter # Revision # After Permit Issued DEPARTMENTS: Bu �^ Bu I g'Div s ona air P Worts '2 t Structural DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete Comments: REVIEWER'S INITIALS: APPROVALS OR CORRECTIONS: Approved ❑ Notation: REVIEWER'S INITIALS: Documents/routing slip.doc 2 -28-02 50 Alpo v- -oc Fire Prevention Incomplete ❑ ❑ Permit Coordinator TUES/THURS ROUTING: Please Route Structural Review Required ❑ No further Review Required DATE: Approved with Conditions DATE: • l 124'! Panning Division IP hY A DUE DATE: 12-19-06 Not Applicable C Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: DUE DATE: 01 -16 -07 Not Approved (attach comments) ❑ Permit Center Use Only CORRECTION LETTER MAILED: • Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: REVISION NO. DATE RECEIVED STAFF INITIALS ISSUED DATE STAFF INITIALS STAFF INITIALS Summary of Revision: Received by: REVISION NO. DATE RECEIVED STAFF INITIALS ISSUED DATE STAFF INITIALS STAFF INITIALS Summary of Revision: Received by: REVISION NO. DATE RECEIVED STAFF INITIALS ISSUED DATE STAFF INITIALS STAFF INITIALS Summary of Revision: Received by: REVISION NO. DATE RECEIVED STAFF INITIALS STAFF INITIALS ISSUED DATE STAFF INITIALS Summary of Revision: Received by: Summary of Revision: ( i i Gro t '. no l E'hYaUJIn /vh e &ham at J1 Received by: Ira K, f"e t.04rt REVISION NO. DATE RECEIVED STAFF INITIALS ISSUED DATE STAFF INITIALS Summary of Revision: Received by: REVISION NO. DATE RECEIVED STAFF INITIALS ISSUED DATE STAFF INITIALS Summary of Revision: Received by: PROJECT NAME: SITE ADDRESS: REVISION LOG PERMIT NO: f law 0 — ' - I,t pL ORIGINAL ISSUE DATE: D (please print) (please print) (please print) (please print) (please print) Project Name: Ga a. a Project Address: Contact Person: 1tLi eakil Summary of Revision: City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3610 Fax: 206 -431 -3665 Web site: httn://www.citukwila.wa.us Revision submittals must be submitted in person at the Permit Center. Revisions will not be accepted through the mail, fax, etc. Date: / / 9 D f Plan Check/Permit Number: ❑ Response to Incomplete Letter # __ ❑ Response to Correction Letter # 111- # I after Permit is Issued ❑ Revision requested by a City Building Inspector or Plans Examiner t,9 ^m - (� �'na O -' Air J 6 h7 t n (MAW cia leppbalwns\orms- applications on line 1, submittal Created: 8 -13 -2004 Revised: h P tS&c �n� 1 e t 1 Phone Number: Sheet Number(s): "Cloud" or highlight all areas of revision including date of revision Received at the City of Tukwila Permit Center by: Entered in Permits Plus on 61( bpl(R- P541-v t S RECE JAN l '8 2001 PERMIT ce 5 P-Zg rr io 3 .4 a, J sitn L 1 r Steven M. Mullet, Mayor Steve Lancaster, Director vin r. 11 r�- Kind of Fixture Fixtur Units Na. of Fixtures Total Fixture Units Public Private Public Private Bathtub and Shower 4 4 Shower, per head 2 2 Dishwasher 2 2 Drinking fountain (each head) 1 .5 Hose bibb (interior) 2.5 2.5 Clolheswasher or laundry tub 4 2 — Sink, bar or lavatory 2 1 I Sink, Clinic flushing 8 8 Sink, kitchen 3 2 Sink, other (service) 3 1.5 Sink, wash fountain, circle spray 4 3 Urinal, flush valve, 1 GPF 5 2 Urinal, Bush valve, >1 GPF 6 2 Water closet, tank or valve, 1.6 GPF 6 3 I (o Water closet, tank or valve, >1.8 GPF 8 4 Non - Residential Sewer Use Certification King County (To be completed for all new sewer connections, reconnections or change of use of existing connections. This form does not apply to repairs or replacements of existing sewer connections within five years of disconnect.) Pursuant to King County Code 28.84, all sewer customers who establish a new sewer customers. The charge is collected semi - annually. All future new service which uses metropolitan sewage facilities shall be subject to a billings can be prepaid at a discounted amount. capacity charge. The amount of the charge is established annually by the King County Council at a rate per month per residential customer or residential customer equivalent for a period of fifteen years. The purpose of the charge is to recover costs of providing sewage treatment capacity for (Please print or type) /� Owner's Name VNe 21 Ulr aft 0►1 (Last, First, Mid Initial) Subdivision Name frovhconter Lot # 40() Subdiv. # Block # Building Name Of applicable) lcii`r iP �}T'l� Property Street Address %CAA v� o g( ?lArin Centr City, State ZiP t W A 9$ IS$ Owner's Phone Number (310 ) cis - 5407 Owner's Mailing Address (if different from above) )I I.DI WI IsN'ire- t1v& 11" "P oor Las MSckS f l gcr,s A. Fixture Units Fixture Units x Number of Fixtures = Total Fixture Units Residential Customer Equivalent (RCE) 20 fixture units equal 1.0 RCE Total No. of Fixture Units 20 1058 (Rev. 1/03) Total Fixture Units 1 2 1 .4 RCE Forting Chun Account # •: • Monthly Rate Six Month Due White – King County Department of Natural Resources and Parks Questions regarding the capacity charge or this form should be referred to King County's Wastewater Treatment Division at (206) 684-1740. Property Tax ID # Party to be Billed (if different from owner) l XT1 , ,:ft Party's Mailing Address: o 'weSlpmA- Pt u � 4tg*vIne `11¢D$) � � 1 City or Sewer District 1 v lA)v LCL Date of Connection Side Sewer Permit # or Property Contact Phone # ( ) Demolition of pre- existing building? 0 Yes 0 No htGl_ Type of building demolished Sewer disconnect date B. Other Wastewater Flow (in addition to Fixture Units identified in Section A) Type of Facility /Process: ho pea ii i&r +te -Ciou) Estimated Wastewater Discharge: Gallons/days Residential Customer Equivalents (RCE): 187 gallons per day equals 1.0 RCE Total Discharge (gaiday) _ C. Total Residential Customer Equivalents: (add A & B) AI• CnvFTJ RECEIVED A DLe 14 2006 PERMITCENTER 1 certify that the information given is correct. 1 understand that the capacity charge levied will be based on this information and any deviation will require resubmission of corrected data for determination of a revised capacity charge. Signature of Owner/ Representative 4 Z'ryt i..r. - -- Print of Owned Representative �UtQ 'f1fY1t.,� ,r Date i �— S - b(J 187 1. 1 RCE RCE Yellow – Local Sewer Agency Pink – Sewer Custo e i License Information License LLRETCL954QQ Licensee Name L & L RETAIL CONSTRUCTION LLC Licensee Type CONSTRUCTION CONTRACTOR UBI 602372596 Ind. Ins. Account Id #I Business Type LIMITED LIABILITY COMPANY Address 1 3750 W MAIN ST STE 4A Address 2 City NORMAN County OUT OF STATE State OK Zip 73072 Phone 4053602775 Status ACTIVE Specialty 1 GENERAL Specialty 2 UNUSED Effective Date 11/18/2005 Expiration Date 11/18/2007 Suspend Date Separadon Date Parent Company Previous License Next License Associated License Bond Information Bond Bond Company Name Bond Account Number Effective Date Expiration Date Cancel Date Impaired Date Bond Amount Received Date #I TRAVELERS CAS & SURETY CO 104644232 11/10/2005 Until Cancelled $12,000.00 11/18 /2005 Business Owner Information Name Role Effective Date Expiration Date LISCHKA, STEPHEN C PARTNER/MEMBER 11/18/2005 Look Up a Contractor, Electrician or Plumber License Detail Page 1 of 2 Washington State Department of Labor and Industries General/Specialty Contractor A business registered as a construction contractor with L&I to perform construction work within the scope of its specialty. A General or Specialty construction Contractor must maintain a surety bond or assignment of account and carry general liability insurance. https: // fortress .wa.gov /lni/bbip /printer.aspx ?License= LLRETCL954QQ 01/18/2007 x x x x x x x x x x x x x x x x x x