HomeMy WebLinkAboutPermit 0225 - Frey & Haertel - Overmeyer Building AdditionBUILDING PERMIT
CIT OF TU KWI LA BUILDING P ,MIT
14475 - 59th Ave. So. / Tukwila, Washington 98067
Applicant to complete numbered spaces only.
BUILDING
PERMIT NO7
N2 225
JOE ADDR ES5
305 Overmyer Drive
GATE
5/14/73
LEGAL
1 DESCR.
LOT NO
BLK 1 TRACT
(SEE ATTACHED SHEET)
OWNER pv- cianA2 4.1-" Alai MAIL ADDRESS ZIP PHONEZ4� _ ggvD
2 Frey & I- aertel 305 Overmyer Dr. Seattle 98188
CONTRACTOR MAIL ADDRESS PHONE LICENSE NO.
3 Self
ARCHITECT OR DESIGNER MAIL ADDRESS PHONE LICENSE NO.
4
ENGINEER MAIL ADDRESS PHONE LICENSE NO.
5
LENDER MAIL ADDRESS BRANCH
Fick. c? a �vt p Cot c- tf o - a o F 3 7
USE OF BUILDING
7
8 Class of work: • NEW J ADDITION • ALTERATION • REPAIR 10 MOVE • REMOVE
9 Describe work: Add offices for sales use
10 Change of use from
Change of use to
11 Valuation of work: $ 5,000.00
PLAN CHECK FEE 14.50
, „f
const. III —N
Occupancy
Group
PERMIT FEE
F
29.00
Division 2
SPECIAL CONDITIONS: Provide exit sigris per UBCy prow
nonabsorbent finish and backings for restroom
walls and floors. Provide items listed in
Size of Bldg. Ft 20, 000
s o. of 1
Max. Load 60
Fire Dept. letter dated May 11, 1973•
1\
Fire
Zono III
Use
Zone C —M
Fire Sprinklers
Required 4 ves •No
APPLICATION
k
ACCEPTED BY
�
Alb—
PLANS CHECKED BY
AP 'R
%
RVED FOR ISS ANC
�''
11�_J e, A �,
BY
No. or
Dwelling Units
OFFSTREET PARKING
Covered
SPACES:
Uncovered
NOTICE
SEPARATE PERMITS ARE REQUIRED FOR ELECTRICAL, PLUMB-
ING, HEATING, VENTILATING OR AIR CONDITIONING.
THIS PERMIT BECOMES NULL AND VOID IF WORK OR CONSTRUC-
TION AUTHORIZED IS NOT COMMENCED WITHIN 60 DAYS, OR IF
CONSTRUCTION OR WORK IS SUSPENDED OR ABANDONED FOR A
PERIOD OF 120 DAYS AT ANY TIME AFTER WORK I$ COM-
MENCED.
I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS
APPLICATION AND KNOW THE SAME TO BE TRUE AND CORRECT.
ALL PROVISIONS OF LAWS AND ORDINANCES GOVERNING THIS
TYPE OF WORK WILL BE COMPLIED WITH WHETHER SPECIFIED
HEREIN OR NOT, THE GRANTING OF A PERMIT DOES NOT
PRESUME TO GIVE AUTHORITY TO VIOLATE OR CANCEL THE
PROVISIONS OF ANY OTHER STATE OR LOCAL LAW REGULATING
CONSTRUCTION OR THE PERFORMANCE OF CONSTRUCTION.
Special Approvals
Required
Not Required
Approved
ZONING
HEALTH DEPT.
FIRE DEPT.
SOIL REPORT
OTHER (Specify)
FOUNDATION
FRAMING
SIGNATURE Or OWNER Ilr OWNER BUILDER)
LJ ✓
FINAL
SIGNAT 'E OR AUTHORIZE, ail�� •ATE)
WH
PLAN CHECK VALIDATION
N
P
OPERLY X/ALIDATED (IN THIS SPACE) THIS IS YOUR PERMIT
CK.
M.O. CASH PERMIT VALIDATION
OCCUPANCY PERMIT REQUIRED
M.O. CASH
DUILDPNG PERMIT
C
CITY OF TUKWILA BUILDING ERMIT
14475 • 59th Ave. So. / Tukwila, Washington 98067
Applicant to complete numbered spaces only.
r JOS ADDn ESS
:5"
3 t: J 5 VU e r VIA .e t 1— 0 N.
DATE
(-5/ // 73
LEGAL
1 DeCR.
LOT NO.
SLR'
TRACT
(IIL'LE ATTACHED SHEET)
OWNE(01 MAIL ADDRESS ZIP PHONE
2 6-C w- 164e.r4 e L 3�sr C70Crmeycr r- /�
t'c, /
,�
CONTPACTOR MAIL ADDRESS PN L LICENSE 110.
WW1
3 5-e t -C
ANCHITECT 011 DESIGNER MAIL ADDRESS PHONE LICENSE NO.
4 11
RNGINE.ER MAIL ADDRESS PHONE LICENSE NO.
J
� Jv\ `
LENDER MAIL ADDRESS
BRANCH •
,. G L.A.) to ^ e N 0 Li i C� 'LN1i
c t
USI. Or BUILDING
l
8 Class of work: ❑ NEW )ADDITION ■ ALTERATION 0 REPAIR ❑ MOVE ■ REMOVE
9 Describe work: Q 4 J. C ?BI..(4`0 A S e--Q 1-4-49-
10 Change of use from
Change of use to
11 Valuation of work: $ ` C7 °b c�+
PLAN CHECK FEE /4 °
PERMIT FEE `i
ELL
SPECIAL CONDITIONS: r�lovi✓l - t x t LL6�1c )rye ()er,
Typo of
Const. ..7.1r —W 1
Occupancy
Group V.
Division
PLOV I e NOt•1AR O12 . aJ - it* P CIC IN •cam •.
}log &'.. V,01 LLS Ji049 i•-ta k Q . prtaIJ(Pt?,. 1 t 1AA1 /45 -O
Size of Bldg.
(Total) Sq. Ft.2011�Q
No. of ,/
Stories 6Pri�
Max. (�,1
Occ. Load `sv
144. En ft& pc -00 4 ( Lr'11eit rj% , •� ►loaf !// ))7 ?,
Fire i
Zona -,. r,.,....
Use
Zone G
Fire Sprinklers r-T
Required OS L..INo
APPLICATION ACCEPTED BY:
��i /�;
_,V -
PLANS CHECKED BY'
APPROVED FOR ISSUANCE BY.
Nn. of
Dwelling Units
OFFSTREET PARKING
Covered
SPACES:
Uncovered
NOTICE
SEPARATE PERMITS ARE REQUIRED FOR ELECTRICAL, PLUMB-
ING, HEATING, VENTILATING OR AIR CONDITIONING.
THIS PERMIT BECOMES NULL AND VOID IF WORK OR CONSTRUC-
TION AUTHORIZED IS NOT COMMENCED WITHIN 60 DAYS, OR IF
CONSTRUCTION OR WORK IS SUSPENDED OR ABANDONED FOR A
PERIOD OF 120 DAYS AT ANY TIME AFTER WORK IS COM-
MENCED.
I HEREBY CERTIFY THAT 1 HAVE READ AND EXAMINED THIS
APPLICATION AND KNOW THE SAME TO BE TRUE AND CORRECT.
ALL PROVISIONS OF LAWS AND ORDINANCES GOVERNING THIS
TYPE OF WORK WILL BE COMPLIED WITH WHETHER SPECIFIED
HEREIN OR NOT, THE GRANTING OF A PERMIT DOES NOT
PRESUME TO GIVE AUTHORITY TO VIOLATE OR CANCEL THE
PROVISIONS OF ANY OTHER STATE OR LOCAL LAW REGULATING
CONSTRUCTION OR THE PERFORMANCE OF CONSTRUCTION.
Spacial Approvals
Required
• Not Required
Approved
ZONING
HEALTH DEPT.
FIRE DEPT.
SOIL REPORT
OTHER (Specify)
FOUNDATION
FRAMING
SIGNATURE or OWNER lir OWNER SLIME/CRT
CZ" c
FINAL
.
SIGNATURE OR AUTHORIZED AGENT /(DATE)
PLAN CHECK VALIDATION
H
OPERLY VALIDATED (IN THIS SPACE) THIS IS YOUR PERMI
M.O. CASH PERMIT VALIDATION
/ —n3 CTCCUPANCY PERMIT REQUIRED
M.O. ,7 CASH
g/
Mr. John Richards
6230.Southcenter Blvd.
Seattle, Washington
Subject: Overmyer Building
Dear Mr. Richards:
Attached please find a wall section diagram and a
floor plan layout for proposed office layout for our
new facility.
We hereby guarantee that all construction will be
performed in compliance with all prevailing codes and
in full compliance with the fire protection requirements.
the basis of the above please issue a building
May 3, 1973
for this construction.
Sincerely,
FREY & HAERTEL
( FIRE DEPARTMENT
CITY oF TUKWILA
• John Richards
Building Department
City of Tukwila.
Dear John:.
Frank Todd, Mayor
5900 SO. 147TH ST.
TUKWILA, WASHINGTON 98067
Fire Prevention Bureau
May 11, 1973
Re: Frey & Haelttel
Office Remodel
Tn,:xegard tO,thib project at 305 Overmyer Drive, the follow
:ing requirements are to' be met regarding fire preventiOnr
• 1. All doors (including exits) to be
(signs) per OSHA Sec. 1910.37(q).
2. Extinguishers will be required per
These shall be hung and identified
requirements in Sec..1910.157.
3. Fork lift trucks must have a dry chemical exting-
uisher (at least 2-3/4 pound) mounted on the truck.
4. Drawings for sprinkler system modification to be
approved by the Washington Survey and Rating
Bureau and the Tukwila Fire Department.
Thank you,
identified
NFPA #10.
per OSHA
•
•
•
•
•
JN:vma
cc: T.F.D. file
James Hoel
Fire Prevention Officer
[I:- tit.
NAY 1 •.11973.
CITY. o';''',TUKWILA..:
PUE3LIC .WORKS DEPT
• ' 242.2177
5230' Sc uthaentor Blvd
27'
.; Exterior wa11's :of Type III buildings should be incombuativle'construc-
tion.. Section 2001. :. .
A property'line should be assumed between'court rialls.to determine
wall and opening protection. Section 504 (c). Also see definition of
court. Section 404. '
T
Exterior (court),walle; within feet of lines should be of
-hour construction. Section '03 (a)•. '
�+
Openings. in exterior (court)' walla within' feet of property .
lines should be protected with three - fourths -hour fire assemblies.
Section-: 03 (b). •
a('
31.
Usable space under the first floor except in Group 1 .(J) 'Occupancies
should be'enclosed as required in Section 1703. .
•
W.
32
0:Fire- resistive construction for structural elements in the exterior.
.walls should comply with Footnote No. 1 of Table No.'17 -A and
clarif ication.
33
`Structural members carrying masonry or. concrete walls in'bttildings
over one`story in height should be protected with'•minimum one -hour
fire protection. Section 1706. ,
IA IN
34'
•
Sufficient details are necessary to show that the. building is at least
one -hour fire - resistive construction throughout in accordance with
Section ' .
i0 -.
35•
Enclosures for floor openings should comply with Table No. 17-A,
Section 1706, and Chapter 30. Details should clearly. indicate this.
.36.
. Building; paper should be applied to exterior walls as specified 'in -
Section :1707 (a). ,
0
37.'
Temporary partitions should conform to the minimum construction
requirements of Section 1705 (a). •
36.
' Nonabsorbent finish and backing for toilet room walls and floor should
Conform to Section 1711 (a). '
39
.Smoke stop partitions. See NFPA 101 required construction 10 -1311 to
10 -1314 including fire stop partitions NFPA 101,' 10- -1316. ' ,
\AV40
.
1 •
Fire and smoke automatic detection system. 'NFPA 101, 10-1316. Fire .
Marshal. Fire Alarm Standard No. F-70-2.
,+11)',
41
•
.Fire retardant treated wood. Section 407. ' Fire Resistance.. , Section
1705, 1801, 1901,,2502 and UBC Standards. s'
cJ
42
'
' Parapet'walls not less than 30 inches in height are 'required. Section
1709. . . •
,'
43
Eave.overhangs and similar architectural projections should'comp.ly
with Section 1710. -
i k/
44
. Metal roofing'(siding) should be bonded and grounded in conformance
with the local electrical code.. Section 1715. •
0
.45 .
•:.Projections beyond the exterior wall.should•not extend.beyondt ,
(a);- A ,point one -third the distance to 'the. property, line from an ex-. •
',terior wall. :Section 504 (b). ' ',
J l • . '.'
PUE3LIC .WORKS DEPT
• ' 242.2177
5230' Sc uthaentor Blvd
1
r
96
.'i occupancies all floors - ward 'for' insbitutional•eleeping shall be
divided into two 'areas, see Section 10.1311 'NFPA. .'10-2311 NFPA but
may not exceed 150,travel distance. 7
97
;Ramp D Occupancies shall not exceed 1,3/16" to 12:', see NFPA Section
5,6121. ,
98 •
. Handrails. for. nursing homes refer to D.S.M. requirements.
99
For. flammable liquids 'storage see SeCti'on 808 and 908 for b Occupancy.
. . '
100;
,. ;.The question of opening or fixed windows has arisen froth time to time
: “for hospital patient rooms. . Because UBC allows fixed windows when a
. building'is mechanically ventilated the Fire Marshal believes because
UBC takes, precedence over NFPA this opening'requirement would not be,
a Fire Marshal requirement, however, it will be prudent to include
opening provisions because of the Federal requirements under NFPA
parts; of life safety code 101. Refer to Section 16- 41.for automatic
' sprinkler requirements and, for 'windowless buildings, also to 1604111
and theappendix notes. ., 1• •
101
•
,For fire stop' partitions nee NFPA 10- 1315. _ . ,' •
•
fir 1 ,. x., +
GROUP r , ,
. ;...._.� �,..
a(
105
'
...
'Notor•vehicle service stations should be of non-oombustible.or,one-
hour. fire- resistive construction.' Section 1102 (b). Heavy timber
-roofs roofs for :one- -story service stations are aiao allowed.
tik
106
. Floors of storage garages should be entirely protected against
saturation. Section 1102 (b) . Asphaltic concrete does not comply.
107
, Storage areas in excess of 1000 square feet in connection with whole,
sale or retail'sales should be separated from the public areas by a
:One-hour fire - resistive occupancy separation.; :Section'1102 (b).
108,
' Light and Ventilation'should comply with Section.1105. • See NFPA 101,
16,4111 Windowless 'Building Requirements. ' •
wkj
109
Exhaust.ventilation at or near floor level io required by Section 1105.
pj .►
110
' A one-hour fire- resistive occupancy.separation'is :required between a
•• boiler room 'or.:central' heating plant and the. rest; of the building.
Section 1108.
•
1 I iI' 1 1 iY 1 f,
'
PUBLIC . WORKS DEPT
242-2177
6230 Southaenter' E31vd
ETTI
GROUP .J
130 Group J Occupancies era Limited to 1000 (3000):square'foot'in floor
.area and ona story in height. Section 1502.
131
132
Exhaust:ventilation,.o,ienings in a garage are required.ny.Section 1504.
Garages ehould,not•open directly into a room.u§ed, for eleepin4 purposes.
Section 1504.
• 133 An approved noncombustible material is required for'garage,floor.
surfaces:.' Sectiori,.1506. ' .Asphaltic concrete. does not comply.
135
EXIT RiQUIRh24ENTS
An o
having
See
ccu�.�ant, load sign,is` required in classrooms, ca�embly areas, etc.,
.an,oedupant load of more than 50. Section 3301 (,j). ►
136 Conforming exits are required from the areas be ow as specified in
Section 3302 (a).
137. Exits should have a minimum separation .of one -fifth the perimeter oi'
the room or area served. Section 3302 (c)'. 'Note that "perimeter" is
along the outer boundary of the room or area served.
134 :wo point in the building should be more than 150 (200) 'feet from an
exterior exit, horizontal exit, enclosed stairway, or exit passageway,
measured in the direction of travel. Section 3302 (d).
139 ' Exit doors should swing in the direction of egress. Section 3303 (b)
serving occupant load of 50 or more 'and hazardous areas.
• 140 Double acting doors aroma allowed where . aervinti a tributary.
occupant load of more than 100. Section 3303 (b).
11+1. Exit doors should be openable from the inside without the use of.a
key,'special knowledge, or effort. Section 3303 (c). Note also that
/ flush bolts or surface bolts are prohibited.
142 , Exit doors should be a minimum size of 3' x 6'8" with a minimum ' door
' swing of 90 degrees.' Section 3303 (d)..
143 . The net dimension (clear width) at doorways should be used in deter-
mining exit widths required by Section 3302 (b). Section 3303 (d). Elms
In consideration of door thicknesses, panic hardware, door swing, etc.
the required exit widths have not been furnished. See door
144 A floor Or landing not more than 2- inches below the threshold is
required on each aide of an exit door. Section' 3303 (h).
• (I occupancies excepted)
145 ,',Doors;should.not project more than 7- inches into the required corridor.
. 'Width wheri..fu11y opined or more than, one -half into. the required, ' ,
PUBLIC WORKS DEPT
242 -2'177
6230 Bouth center Blvd
eot
des by
:ri.
Ots-
i
tA
ofr
•
.r*.rtiti.rrrw.wmwth.Iwnw......e .flY.w++rw►�w.,* 4r 4t.Ke4U.r Ue*.', 34.
.wWr....ri. r
x�+ 411.44aa:4/
corridor width when in any position. Section 3304 (c). 1
Revolving (sliding) '(overhead) doors are not permitted as exit doors.
Section 3303 (f).
Exit doors should provide immediate access to an approved means of
:egress. Seetion 3303 (g). Exiting through another room does not
comply.
For exits through adjoining or accessory rooms'or areas see Section
3302 (e).
Corridors should have a minimum width of 44 inches.
except C.and D occupancies.
Corridors serving'nonarnbulatory persons should have an .8 foot minimum
width. Section 3318 (c).
Section 3304 (b)
Dead end of corridors and exit balconies are limited to 20 feet.
Section 3304 (f). -1�.
Walls and ceilings of corridors should be on one -hour fire - resistive
construction. Section 3304 (g). An architectural section through •
the corridor is necessary to determine how this is accomplished.
Interior openings into corridors should be protected as set'forth in
Table No. '33-Ii and Section 3304 (g) •
Openings, located between the end of an exterior, exit balcony and the
nearest stairway should be protected as required for corridors. ..
Section 3304 (g).
Stairway -' should have a,minimum width•of:
inches. Trim and handrails should not project more.than 3;s inches
into the required width. Section 3305 (b).' r,.
• Risers on .stairways should not exceed 7 • inches and runs should not be Vi,
leas than 10 inches. Section 3305 (c).
' Landings' on stairways should have dimension in the direction of.
travel equal to the.width of the stairway but need not exceed 4 feet.
Section 3305 (f).
Basement 'portion of stairways should have an approved barrier where
continuous to upper floors in an exit enclosure.. Section 3305 (g).
Vertical distances between stairway landings are limited to 12 feet.
.Section 3305 (h).
Aandraile should be placed not'less than 30 inches nor more than 31.
inches above the tread. Section 3305 (i). Two handrails are required
`where stairways exceed 44 inches in width. No handrails.if less than
four risers.
' Guardrails for: stairs, balconies, and landings should conform with
',Section 1714. .Note that maximum clearance between intermediate rails
i
is 9 inches. ' .
Openings in exterior walls'within 10 feat or exterior stairways should
be protected 'with self - closing, three -- fourths -hour fire -- resistive
'assemblies. Section.3305 (k). ;
Enclosed. usable :epace under interior stairways .should :be. protected : on
. :projeot ;title
•
PUDLIC WORKS DEPT
242 2177
6230 6outhoenter Blvd
I I the • enclosed 'side., as required for .one -.hour.. fare - resistive Construction.
Section 3305 (m).'
•
, 164 Noncombustible exterior stairs are required.', Section 3305 (m). See
exception Type -3 and 5.
I '165. Exterior stairs should not project into,an area (yards er,,counts)
where' wall openings must be protected...Soction'3305
166 One stairway should extend to. the roof. Section•3305 (n). 'It'must be.
• . in a smokeproof enclosure in buildings of.floor 75'. above highest '
'grade. For details see. Section 3309 (b)..
jtv • 167 Six toot 6 inch minimum headroom clearance for stairways should be
indicated on plans. Section 3305 (0). Note that this is from a plan Elmm
tangent to the stairway tread nosings. ^,
NA- 168 Ramp slopes should not, exceed one foot in eight 4fee feet. 3306c,d.
,,, 169 Surface of ramps should be roughened, or of a ,nonslip material..
Section 3306 (f).
170 Stairways should be enclosed as specified in Section 330E3.
(b):'One (two) -hour fire- resistive walls are required.'
. c; Only exit doors are allowed to open into exit enclosures. boors
should be labeled one (one-and-one-half)-hour fire assemblies.
Exit enclosures should include a corridor on the ground floor
:,extending to the exterior. Fire - resistive construction should
be required for,the exit enclosure, including protected openings.
.Only exit doors are permitted to open into the corridor.
(e),.•An.approved barrier is required at the ground floor to prevent.
people from accidentally continuing to the lower level.,
(f) Usable space is not allowed under the stairs.' ;
171 One exit from the building requires a' smokeproo£•.enclosure.,See
,Section 3309. •
:1.72 ,Openings•into, exit courts less than 10 feet wide should be'protectedL
with labeled 45 minute fire assemblies. Section 3310.(d). .Also see,
"exit court ". definition in Section 3301 (e).. Openings. more than• 10
feet above the court floor are exempted.
000' J73 ' No .openings other. than required exits aro permitted ' in exit passage-
ways.. The passageways should be :of one or'two -hour fire - resistive
,construction. Section 3311 (a).
174
'.Exit illumination and 'signs should be
Suction 3312..
175 Aisle (cross Aisle) is auditorium should have a minimum width of
Section 3313 (b).' Section 3312 (c).
provided' in conformance. with
01'- 176
0 :177 Main and side•exitn'in conformance' with 'Section 3315 are required for
13 -2(1) Occupancies. • Section 3316 (a). '
178 , Corridors of 'Group C Occupancies should have'a width r .equired by
Section •3302' plus 2 £eet, but not less than 6 ,feet.' 'Section. p170).:.
•
Panic hardware is required on exit doors serving Group B Occupancies
having an occupant •load'of more than 100. Section'3316:(a). In lieu
of this, doors.shall'have no locks or latches. . '
PUE"LIC . WORKS DEPT
• ' 242 er 2177.
6230 Southoenter Ellvd
Date
MTO 11
FREY & HAERTEL ORDER WORK SHEET
Confirms to
Via (Phone or Telex)
Write S/O b
Direct Order ❑
Taxable O
Place Order ❑
Write P/o 0 11
D
Direct Sale ❑
Cr. OK ❑ Cust. P.O. 1l
Sold To:
To:
Ackn. ❑ to:
Confm ❑ to •
Ship To:
Ship To:
We delvr. ❑ Cust W/C ❑
Other
Frgt: Ppd. ❑ Coll. ❑ Ppd. & Chg. Cust. ❑
Taxable
D
Terms
To Ship Coll. ❑ Ppd. ❑
Other
Prices FOB:
We to pay Frt.
ra
Prepay & Chg. us ❑
Our Whs. ❑ Deld. ❑ Fact. ❑
Other
Terms:
Via
Shippg. Prom.
Shippg. Prom.
CREDIT INFORMATION
BANK
TRADE REF
OTHER
PIECES LIN /FT
WEIGHT
DESCRIPTION
CODE
S/O PRICE
P/0 PRICE
1
2
3
4
5
6
7
8
9
10
11
Trade discounts allowed Frey & Haertel:
Additional Comments see Reverse 0 (Jr( ite)
4.11.
v ky
3-7 is ,_
; 'I; 1--- 1J • t4
u
.-S 1(4 ,J 1
eS-
Date
MTO #
FREY & HAERTEL ORDER WORK SHEET
Write 5/0 N
Place Order ❑
Direct Order ❑
Taxable
Write P/0 ❑ 1!
Direct Sale ❑
Cr. OK ❑ Cust PO 11
Sold To:
To:
Ackn. ❑ to:
Confm ❑ to:
Ship To:
Ship To:
We delvr. ❑
Other
Cust W/C ❑
Taxable
0
Terms
Frgt: Ppd. ❑ Coll. ❑ Ppd. & Chg. Cust. ❑
To Ship Coll. ❑ Ppd. ❑
Other
Prices FOB:
Our Whs. ❑ Deld. ❑ Fact. ❑
We to pay Frt.
0
Prepay & Chg. us
Other
Terms:
Via
Shippg. Prom.
Shippg. Prom.
Confirms to
Via (Phone or Telex)
CREDIT INFORMATION
BANK
TRADE REF
OTHER
PIECES LIN /FT
WEIGHT
DESCRIPTION
CODE
S/O PRICE
P/O PRICE
1
2
3
4
5
6
7
8
9
10
.
11
Trade discounts allowed Frey & Haertel:
Additional Comments see Reverse 0 (i ,3te)
Signco
s "T