Loading...
HomeMy WebLinkAboutPermit 0302 - SeaTac MedicalCI1 >r OF TUKWILA BUILDING PtRMIT BUILDING PERMIT 14475 - 59th Ave. So. / Tukwila, Washington 98067 Applicant to complete numbered spaces only. a BUILDING PERMIT NO. NR 302 JOB ADDRESS 1145 Andover Park West DATE 9/28/73 LEGAL 1 DESCR. LOT NO. BLK TRACT ( ISEE ATTACHED SHEET) OWNER MAIL ADDRESS ZIP PHONE 762 -2555 2 Bruce E. McCann 8013 Perimeter Rd. So. Seattle, Wa. 98108 CONTRACTOR MAIL ADDRESS PHONE 762 -2555 LICENSE NO. McCann Construction Co., Inc. 8013 Perimeter Rd. So. 233 - 012283 ARCHITECT OR DESIGNER MAIL ADDRESS PHONE LICENSE NO. McCann Construction Co., Inc. ENGINEER MAIL ADDRESS PHONE 624-7045 LICENSE NO. Olsen and Ratti 1411 Fourth Avenue Building Seattle, Wa. LENDER MAIL ADDRESS BRANCH 6 UGC OF BUILDING Warehouse 8 Class of work: 0 NEW JPKADDITION 0 ALTERATION • REPAIR 0 MOVE • REMOVE s Describe work: Tenant Improvements 10 Change of use from Change of use to 11 Valuation of work: $ 20 000. PLAN CHECK FEE 2 9.5o PERMIT FEE 59.00 SPECIAL CONDITIONS: Type of const. III —N Occupancy Group F Division 2 1. This improvement- 214 "N" — 19,157 sq. ft. 64 Occ. I (Total) Sq. 5, 810 (Fire Zone III S . of ] Use Zone CM Max. Load 6 64 Fire Sprinklers Required Eyes ❑No 2. Requirements of Fire Dept. letter 9/25/7; apply. APPLICATION ACCE' ED B I ' 1.... ,, `�.....di ai. SEPARATE PERMITS ING, HEATING, VENTILATING THIS PERMIT BECOMES TION AUTHORIZED IS CONSTRUCTION OR PERIOD OF 120 DAYS MENCED. I HEREBY CERTIFY APPLICATION AND KNOW ALL PROVISIONS OF TYPE OF WORK WILL HEREIN OR NOT, THE PRESUME TO GIVE PROVISIONS OF ANY CONSTRUCTION OR �Lo7V PLAVE ARE NULL NOT WORK THAT LAWS BE AUTHORITY OTHER THE CHEC . aY 1 N •I CE REQUIRED OR AIR AND VOID COMMENCED IS SUSPENDED AT ANY TIME I HAVE THE SAME AND ORDINANCES COMPLIED GRANTING TO STATE PERFORM \\ / FOR CONDITIONING. READ TO WITH OF VIOLATE 0 ELECTRICAL, IF WORK WITHIN OR AFTER AND BE A L AL AP' ABANDONED TRUE GOVERNING WHETHER PERMIT LAW OF ED F.' OR CONSTRUC- 60 DAYS, WORK EXAMINED AND OR CANCEL REGULATING CONSTRUCTION. UA 1 ( - PLUMB- OR FOR IS COM- THIS CORRECT. THIS SPECIFIED DOES NOT THE Y. ,. IF A No. of Dwelling Units OFFSTREET PARKING Covered SPACES: Uncovered Special Approvals Required Not Required Approved ZONING HEALTH DEPT. FIRE DEPT. SOIL REPORT OTHER (Specify) FOUNDATION FRAMING FINAL SIG - OF OWNS NE Ch) SIGNA E OR AUTHORIZED AGENT (OATEI WHE ROPERLY VALIDATED ON THIS SPACE) THIS IS YOUR PERMIT, PLAN CHECK VALIDATION CK. M.O. CASH PERMIT VALIDATION c1 y (011 13 OCCUPANCY PERMIT REQUIRED u 5C M.O. CASH /4- H • tf 47 ELath ; .va. Co. / . ,.i;w;la, JOB ADGR ES� 0 DATE Se.tember 25 1971 Fic `� A4. „ 1 LEG DESAL CR. 4 O NO. BLK TRACT (tSEE ATTACHED 'SHEET) OWNER MAIL ADDRESS O PHONE 2 Bruce E. McCann 8013 Perimeter Road Sou - Seattle 98108 762 -2555 CONTRACTOR MAIL ADDRESS PHONE LICENSE NO. 3 McCann Construction Company, Inc. 8013 Perimeter Road South 762 -2555 _' 283 ARCHITECT OR DESIGNER MAIL ADDRESS PHONE filiiiPP `, McCann Construction Co., Inc. 8013 Perimeter Road South 762 -2555 ENGINEER MAIL ADDRESS P,. 0. 5 Olsen and Ratti 1411 Fourth Avenue Building - Seattle 624. -7045 LENDER MAIL ADDRESS BRANCH 6 UEL OF BUILDING 7 Warehousing 3 Class of work: • NEW aADDITION • ALTERATION ❑ REPAIR ❑ MOVE • REMOVE 9 Describe work: Tenant Improvements 10 Change of use from Change of use to 1 Valuation of Work: 20,000 ' PLAN CHECK FEE 29.50 PERMIT FEE 59.00 SPECIAL CONDITIONS: Typo of Const. IIIN Occupancy Group F* No. of Stories 1 Division �2 Max, • Occ. Load ,• IyrtiS /f4pF-o mfr: ZI4 "N�) - * //� 151 'h 4 dC-G' /f - _Iffy . Sizo of Bldg. (Total) Sq. F�;� I if: - .'.r.)f Q.y .i /J !(' r. !(.. ('k A/, C. 111(e. i2 ` /i Qe e� , Fire Zone i ! Uso /�� Zone J4 Firo Sprinklers Required gYDs • No APPLICATION ACCEPTED BY PLANS CHECKED BY: APPROVED FOR ISSUANCE BY: No. of Dwelling Units none OFFSTREE T PARKING Covered SPACES: Uncovered 10 NOTICE SEPARATE PERMITS ARE REQUIRED FOR ELECTRICAL, PLUMB• ING, HEATING, VENTILATING OR AIR CONDITIONING. THIS PERMIT BECOMES NULL AND VOID IF WORK OR CONSTRUC- TION AUTHORIZED IS NOT COMMENCED WITHIN 60 DAYS, OR IF CONSTRUCTION OR WORK IS SUSPENDED OR ABANDONED FOR A PERIOD OF 120 DAYS AT ANY TIME AFTER WORK IS COM- MENCED. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE AND CORRECT. ALL PROVISIONS OF LAWS AND ORDINANCES GOVERNING THIS TYPE OF WORK WILL BE COMPLIED WITH WHETHER SPECIFIED HEREIN OR NOT, THE GRANTING OF A PERMIT DOES NOT PRESUME TO GIVE AUTHORITY TO VIOLATE OR CANCEL THE PROVISIONS OF ANY OTHER STATE OR LOCAL LAW REGULATING CONSTRUCTION OR THE PERFORMANCE OF CONSTRUCTION. Spocial Approvals Required Not Required Approvod ZONING HEALTH DEPT. FIRE DEPT. SOIL REPORT OTHER (Specify) FOUNDATION FRAMING FINAL SIGNATURE Of OWNER (IF OWNER BUILDER) • SIGNATURE OR AUTHORIZED AGENT (DATE) W -PflOPERLY VALIDATED (IN THIS SPACE) THIS IS YOUR PERM JAI PLAN CHECK VALIDATION CK. M.O. 0., 1i CASH PERMIT VALIDATION OCCUPANCY PERMIT REQUIRED fCK. M.O. CASH 4?-1 -06 That portion of the Southwest a of the Southeast of Section 26, and of the Northwest 14- of the North- east 14 of Section 35, Township. 23 North, Range 4 East, W.M., in the City of Tukwila, King County, Washington, described as follows: Beginning at the Northeast corner of said North - west 1 of the Northeast-1/4 of Section 35; Thence North 87 °44'08" West along the North line of said Northwest h of the Northeast 14 a distance of 30.00 feet to the West margin of Andover Park West; Thence: North'O1 °47'29" East along said West margin a dis- tance of 115.66 feet; Thence North 87 °55'02" West a distance of 494.10 feet to the True Point of Beginning. Thence South O1 °51'03" West a distance of 797.00 feet Thence North 87 °55'02 "•West a distance of 216.60 feet; Thence North 01 °51'03" East,a distance of 797.00 feet; Thence South 87 °55'02" East a distance of 216.60 feet to the True Point of Beginning. S'.-,/l. • �,.. ..... ... .... L'::a, I, ti. c........., .C,. L.. ,..1 Applicant to completa numbP.red spaces on /y. Boa Ao:,A t5s 1 1 DZSCA. ..OT NO. eLK TRACT ;2 Bruce E. McCann MAIL ADDRESS ZIP 14 -M" DATE :September 25,197 (3SEC ATTACHED SHCCT) PHONE 8013 Perimeter Road South - Seattle 98108 762 -2555 CONTRACTOR MAIL ADDRESS PHONE LICENSE NO. McCann Construction Company, Inc. 8013 Perimeter Road South 762 -2555 233 - 012283 AR:n1 TLC! OH DESIGNER .• MAIL ADbRE59 4 McCann Construction Co., Inc. PnONE 8013 Perimeter Road South 762 -2555 Er.GI:._ER o Olsen and Ratti V MAIL ADDRESS P, 1411 Fourth Avenue Building - Seattle LCNOZR MAIL AOaRE59 .. ..:. of OJI'...DING 7 Warehousing 624 -7045 3 Cl?. of work: 9 Dascriba work: Tenant Improvements ❑ NEW RADOITION ❑ ALTERATION LICENSE NO, LICENSE NO. SRAIICH ❑ REPAIR ❑ MOVE ❑ REMOVE 10 Change of use from Champ of use to 11 Valuation of work: $ 20.000 SPECIAL CONDITIONS: PLAN CHECK FEE 29.50 PERMIT FEE . 59.00 Typo of Const. IIIN Division F -2 No. of Stories A.'PLICATION ACCEPTED BY; PLANS CHECKED BY: APPROVED FOR ISSUANCE BY: NOTICE SEPARATE PERMITS ARE REQUIRED FOR ELECTRICAL, PLUMB- INC, HEATING, VENTILATING OR AIR CONDITIONING, THIS PERMIT SECOMZ-S NULL AND VOID IF WORK OR CONSTRUC- TION AUTHORIZED IS NOT COMMENCED WITHIN 60 DAYS, OR IF CONSTRUCTION OR WORK IS SUSPENDED OR ABANDONED FOR A PERIOD OF 120 DAYS AT ANY TIME AFTER WORK tS' COM- MENCED. I HEREBY CERTIFY THAT 1 HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE AND CORRECT. ALL PROVISIONS OF LAWS AND ORDINANCES GOVERNING THIS TYPE OF WORK WILL BE COMPLIED WITH WHETHER SPECIFIED HEi:EIN OR NOT, THE GRANTING OF A PERMIT DOES NOT or :ESUME TO GIVE AUTHORITY TO VIOLATE OR CANCEL THE P.OVISIONS OF ANY OTHER STATE OR LOCAL LAW REGULATING CONSTRUCTION OR THE PERFORMANCE OF CONSTRUCTION. Di GAA7URE Of OWNER (I/ OWNER e'UIt.OEN) SIGNATURE OR AUTHORIZED AGENT {GATE) Fire Zone 2 No. of Dwelling Units none Special Approvals I— Required ZONING 1 Use Zone CM Max. Occ. Load 10 Piro SprInklers Required ®Yos ❑No OFFSTREET PARKING SPACES: Covered HEALTH DEPT. FIRE DEPT. Uncovered 10 Not Raquirad Approved SOIL REPORT FOUNDATION I FRAMING FINAL WEN PROPERLY VALIDATED (IN THIS SPACE) THIS tS YOUR PERMIT PLAN CHECK VALIDATION CK. M.O. CASH PERMIT VALIDATION cK. OCCUPANCY PERMIT REQUIRED M.O. CASH That portion of the Southwest 4 of the Southeast 4 of Section 26, and of the Northwest 4 of the North- east 4 of Section 35, Township 23 North, Range 4 East, W.M., in the City of Tukwila, King County, Washington, described as follows: Beginning at the Northeast corner of said North- west 4 of the Northeast-4 of Section 35; Thence North 87 °44'08" West along the North line of said Northwest 4 of the Northeast 4 a distance of 30.00 feet to the West margin of Andover Park West; Thence North.01 °47'29" East along said West margin a dis- tance of 115.66 feet; Thence North 87 °55'02" West a distance of 494.10 feet to the True Point of Beginning ;. Thence South O1 °51'03" West a distance of 797.00 feet; Thence North 87 °55'02 ".West a distance of 216.60 feet Thence North 01 °51'03" East, a distance of 797.00 feet; Thence South 87 °55'02" East a distance of 216.60 feet to the True Point of Beginning. TO McCann Construction Col, any, Inc. 8013 Perimeter Road South Boeing Field SEATTLE, WASHINGTON 98108 206 RO 2-2555 206 RO 2-8124 �. f 7"t., ?re_ GENTLEMEN: WE ARE SENDING YOU ❑ Shop drawings ❑ Copy of letter LET :OCR OF MaK611 aTP1TaR DATE JOD NO. - 73 ATTENTIO �c�l,c�rcfs RE: f 4J r ` � Q.r ! A �ut ldl�r �2j� /t ,,mote /, mc�` Attached ❑ Under separate cover via ❑ Prints ❑ Change order ❑ Plans the following Items: ❑ Samples ❑ Specifications ❑ COPIES DATE NO. DESCRIPTION 2- 2if 73 THESE ARE TRANSMITTED as checked below: ❑ For approval ❑ Approved as submitted ❑ Resubmit copies for approval ❑ For your use ❑ Approved as noted ❑ Submit copies for distribution As As requested ❑ Returned for corrections. ❑ Return corrected prints ✓ ❑ For review and comment ❑ ❑ FOR BIDS DUE 19 ❑ PRINTS RETURNED AFTER LOAN TO US REMARKS COPY TO SIGNED: Iwo NDD —N,. 4[41 Woos S.wti.4... Nowt Wu It enclosures are not as noted, kindly notify at onc.. r- Tukwila, Waahin st®n 30087 talaphana C SOW) fi24E E177 September 27, 1973 2 ® McCann Construction Co., Inc. 8013 Perimeter Road So. Seattle, Washington 98108 Attention: Mr. Hal Blean he Re: Tenant "N" he EC Gentlemen: Q ®, The following items need to be clarified prior to issuance of a ipermit: uI w 1. Please assign a definite and permanent address to this space from the series of addresses assigned to this building in 1972. 2. The occupant load of this space is 64 occupants. Therefore, two (2) exits are required. These exits must be placed at least one —fifth the perimeter of the space apart, 1/5 p = 110 feet. UBC Table 33 —A, UBC Sec. 3302 (c). Because an exit pathway from the warehouse goes through the office area; the corridor, the general office area and the reception area must be made to comply with a one— hour enclosure. This would include ceilings, walls and labeled door and jamb assemblies. UBC Sec. 3304 (g). Please find enclosed one copy of the Tukwila Fire Department plans review of your project. F- After compliance with the above and enclosed comments, a buildin () permit may be issued. 2 2 IJ JER /ma Encl: 1 Very truly yours John E. Richards Off -e Engineer FIRE DEPARTMENT CITY or TUKWILA John Richards Building Department City of Tukwila Dear John: Frank Todd, Mayor 5900 SO. 147TH ST. TUKWILA, WASHINGTON 98067 Fire Prevention Bureau September 25, 1973 Re: Seatac Medical & Scientific Co. In reviewing the above mentioned project plans, please note the following items: 1. One additional exit is required per UBC Sec. 3302. 2. All doors, including exits shall be identified per OSHA Section 1910.37 (q). 3. Per UBC Sec. 3303, exit doors shall swing in the direction of travel when serving an occupant load of 50 or more. Per UFC Sec. 10.104 (b), "All doors in or leading to exits shall be maintained openable from the inside without the use of a key or any special knowledge or effort at all times when the build- ing or area served thereby is occupied". Sprinkler system shall be extended to cover all office areas. Hose station coverage shall be maintained per Ordinance #730. Areas around and in front of sprinkler risers and electrical power panels are to be kept clear of all materials for a distance of 3 feet. To assist this requirement, please paint a 4 inch wide RED stripe on the floor 3 feet in front of and 3 feet on each side of the risers and panels. Inside these red lines, paint 4inch.high letters stating "KEEP CLEAR". 5. Fire extinguishers shall be provided per NFPA #10, as a minimum requirement. When,in the opinion of the Fire Prevention Bureau, building contents or operations therein are of a hazardous nature, additional extinguishers ( in excess of NFRA requirements) may be required. Extinguishers shall be located so as to be in plain view (if at all possible). If not in plain view, they shall be identified with a sign stating, "FIRE EXTINGUISHER" with an arrow pointing. When extinguishers are hung on posts or columns, the post or- oolumn shall be painted bright red for a distance of 12 inches down from the ceiling (or roof). If the color of extinguishers is other than red, they shall be provided with a background or mounting board, red in color, not less than 2 square feet in size. Please include these comments in your review of the above mentioned project.