Loading...
HomeMy WebLinkAboutPermit 2923 - Patton Residence - HeatersPERMIT TUKWIILA THIS BUILDING ERMIT MUST BE P STED CONSPICUOUSLY ON BUILDING PERMIT NUMBER ;29°7-5 Control Number 84 -332 Job Address h 13930 56 P1 So. Tenant /Owner Jim & Marilyn Patton Occ. Date f Issgan9e /) " //- Z Description of Work Install 2 wood heaters Legal Description D Attadhed Property Owner Address 13930 56th P1. So. Rebar Phone Jim & Marilyn Patton Tukwila, WA 98188 Footing 655 -9882 Engineer /Architect Address Fdtn. Phone Contractor Address 4322 So. 179th 18.00 Phone Rainier Masonry Seattle, WA 98188 Frame 854 -9881 Authorized Agent License No. tValue of Work RA- IN- IM -196PG i 1,000 Fire Protection Use Zone Type of kff0F9Ofeeefftelt4y R -1 Construction _ Issued By: .. -. lim Sprinklers El Detectors Size of Unit or Building Uses Sq.Ft. Occ. Occ Load Fees Amt. Date Rec. 4# Rebar VA.-- Footing 2nd F1. Fdtn. Bldg. 18.00 ,o-7 j-/ T Frame Demo. Bond Wall Bd. Total Tot. Tot. Total 30.00 Special Conditions Approved for Issuanc NOTICE THIS PERMIT BECOMES NULL AND VOID IF WORK OR CONSTRUC- TION AUTHORIZED IS NOT COMMENCED WITHIN 180 DAYS, OR IF CONSTRUCTION OR WORK IS SUSPENDED OR ABANDONED FOR A PERIOD OF 180 DAYS AT ANY TIME AFTER WORK IS COMMENCED. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE AND CORRECT. ALL PROVISIONS OF LAWS AND ORDINANCES GOVERNING THIS TYPE OF WORK WILL BE COMPLIED WITH WHETHER SPECIFIED HEREIN OR NOT. THE GRANTING OF A PERMIT DOES NOT PRESUME TO GIVE AUTHORITY TO VIOLATE OR CANCEL THE PROVISIONS OF ANY OTHER STATE OR LOCAL LAW REGULATING CONSTRUCTION OR THE PERFORMANCE OF CONSTRUCTION. ,.,r ` ,...� -. ` . .. y . /mil % L Sign �ature of Contactor or Authorized Agent Date\ /��. -/_ <9 INSPECTION RECORD - 433 -1845 Type Insp. Date Notes Setback Rebar Footing Fdtn. Slab Frame Wall Bd. Dept. Approvals Req'd Insp.I Date Planning 'Div. Health Dept. Public Works Dept. Plumbing Electrical -tert. of-Occupancy _ I FINAL APPROVALS: Fire Dept. Date Bldg. Official Date THESE PREMISES SHALL NOT BE OCCUPIED UNTIL ALL APPROVALS HAVE BEEN SIGNED. CPS No. I BUILDING PERMIT CITY OF TUKWILA THIS ERMIT MUST BE POSTED CONSPICUOUSLY ON BUILDING PERMIT NUMBER 67 C) -) Control Number ro._;m Job Address 13:330 56th P1. So. Tenant /Owner I Jim t' i4arilyn Patten Date ,of Issuance '0 ,'- `: � c. Description of Work Install 2 wood heaters Legal Description L=3 Attached Property Owner Address .13 .3U both I' I. 5O. Phone Jim & Marilyn Patton Tukwila, WA 98181; G55-9682 Engineer /Architect Address Phone Contractor Address C12.Z So. i / 'ith Phone Rainier iflasonry Seattle, WA 98188 854• -9881 Authorized Agent License No. Value of Work .) :4 / RA-1M- IM -196PG 1,000 Fire Protection Use Zone Type of App1: ='Attepttd=By D Sprinklers co Detectors R-1 Construction Issued By: -' Size of Unit or Building = Uses Sq.Ft. Occ. Occ,. Load - Fees Amt. Date - Rec. 1st Fl. Rebar t� -.: "> /I• P.C. i�'.0u 9 -2t 3��71 2nd Fl. - Bldg. 10.00 /0 -1 .) :4 / Frame Demo. Bond Wall Bd. -- �,Q -/ pae.Y1irh ;%id- i Total Tot. Tot. Total 30.00 Special Conditions Type Insp. Date Notes Setback Rebar Footing Approved for Issuance 8' i' 5'- NOTICE THIS PERMIT BECOMES NULL AND VOID IF WORK OR CONSTRUC- TION AUTHORIZED IS NOT COMMENCED WITHIN 180 DAYS, OR IF CONSTRUCTION OR WORK IS SUSPENDED OR ABANDONED FOR A PERIOD OF 180 DAYS AT ANY TIME AFTER WORK IS COMMENCED. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE AND CORRECT. ALL PROVISIONS OF LAWS AND ORDINANCES GOVERNING THIS TYPE OF WORK WILL BE COMPLIED WITH WHETHER SPECIFIED HEREIN OR NOT. THE GRANTING OF A PERMIT DOES NOT PRESUME TO GIVE AUTHORITY TO VIOLATE OR CANCEL THE PROVISIONS OF ANY OTHER STATE OR LOCAL LAW REGULATING CONSTRUCTION OR THE PERFORMANCE OF CONSTRUCTION. L Signature of Contractor or Authorized Agent. Date =, /0`/ 1'c INSPECTION RECORD - 433 -1845 Type Insp. Date Notes Setback Rebar Footing Fdtn. Slab Frame Wall Bd. -- �,Q -/ pae.Y1irh ;%id- i Dept. Approvals Req'd Insp. Date Planning 'Div. Health Dept. Public Works Dept. Plumbing Electrical Cert. of Occupancy( FINAL APPROVALS: Fire Dept. — Date Bldg. Offici D at /Lz'43- THESE PREMISES SHALL NOT BE OCCUPIED UNTIL ALL APPROVALS HAM BEEN SIGNED. CPS No. 1 CITY OF TUK'WRA APPROVED. SEP28 1964 COMBUSTIBLE WA MASONRY PAD (HEARTH EXTENSION) F.IGURE 1 MINIMUM CLEARANCES CITY OF TUKINILA APPROVED SEP 281984 NNUIEU BUILDING DIVISION 21 min 31 min CO LBUSTIBLE WALL 27 ii MASONRY PAD / \ (HEARTH /EXTENSION FOR ALTERNATIVE FIGURE 2 INSTALLATIONS RECEIVCI O crry OF TUK+viLA SEP 27 19 8UILU1NGi DLiP(. 27' TYPICAL CHIMNEY INSTALLATIONS USE ONLY U.L. LISTED, INSULATED, LOW HEAT, OR CLASS "A" CHIMNEY SYSTEMS THROUGH CEILINGS, ATTIC, ROOF OR WITHIN CLOSED AREAS. A 2" CLEARANCE TO ADJACENT COMBUSTIBLES MUST BE MAINTAINED WITH CLASS A CHIMNEYS. THE CHIMNEY MUST EXTEND A MINIMUM OF 2 FEET ABOVE ANY ROOFLINE WITHIN TEN FEET OF THE PIPE HORIZONTALLY. THE CHIMNEY MUST EXTEND ABOVE THE ROOF BY 3 FEET MINIMUM. KEEP SCREENED CAP FREE FROM PITCH BUILD UP AT ALL TIMES. page 2 GENERAL As THE NEW OWNER OF AN AIR -TIGHT STEPDOWN STOVE, YOU CAN EXPECT MANY YEARS OF COMFORTABLE HEAT AND SAVINGS AS COMPARED TO A CONVENTIONAL HEATING SYSTEM, TO ASSURE THAT YOUR STOVE OPERATES PROPERLY AND SAFELY, THOROUGHLY READ THROUGH THESE INSTRUCTIONS BEFORE PROCEEDING WITH THE INSTALLATION, THIS STOVE HAS BEEN TESTED TO RIGID UNDERWRITER'S LABORATORIES STANDARDS BY WARNOCK HERSEY PROFES- SIONAL SERVICES LIMITED AND IS LISTED TO U,L., U.L.C. AND 1.C.B4O. SPECIFICATIONS. THE INSTALLATION OF A WOODBURNING STOVE MUST ALSO MEET LOCAL BUILDING CODES AND ORDINANCES, BE SURE TO CHECK ON THE SPECIFIC CODES IN YOUR CITY AND /OR STATE BEFORE INSTALLING YOUR STOVE. MATERIALS MOST HARDWARE OR BUILDING MATERIAL STORES CARRY THE PROPER STOVE INSTALLATION MATERIALS WHICH ARE APPROVED FOR THAT PURPOSE, CONSULT YOUR DEALER FOR ASSISTANCE IF YOU HAVE ANY QUESTIONS, THE FOL- LOWING MATERIALS ARE REQUIRED TO PROPERLY AND SAFELY INSTALL YOUR NEW STEPDOWN STOVE: ITEM 1: (1) - 8" SINGLE WALL PIPE SYSTEM (FROM STOVE TO CEILING), 24 GAUGE MINIMUM THICKNESS STEEL, ITEM 2: (1) - U.L. LISTED, INSULATED, LOW-HEAT CHIMNEY SYSTEM (THROUGH COMBUSTIBLE WALLS, CEILINGS, ATTIC AND ROOF). ITEM 3: (1) - HEARTH EXTENSION, WHICH MUST BE MOUNTED UNDER THE STOVE, MADE FROM A MINIMUM OF 3/8 . INCH THICK ASBESTOS, MILLBOARD, MASONRY OR EQUIVALENT NON-COMBUSTIBLE MATERIAL, 48" X 48" IN SIZE (SEE FIGURE 1). CITY OF 710, INSTALLATION SEP 2 u STEP 1: REMOVE THE STOVE FROM ITS CARTON AND CHECK TO BE SURE IT IS COMPLETE AND THAT THE EIHASiv Ote!" BEEN NO DAMAGE FROM SHIPPING. IF YOU DISCOVER DAMAGE, REPORT IT TO THE FREIGHT LINE THAT DELIVERED YOUR STOVE. IF YOUR STOVE WAS PICKED UP FROM A DEALER'S STORE, OR DELIVERED BY HIM, MAKE ANY CLAIMS DIRECTLY TO THE DEALER AS SOON AS POSSIBLE, INSPECT YOUR STOVE AND MAKE SURE ALL PARTS ARE IN-PLACE AND OPERATE PROPERLY PER THE OPERATION INSTRUCTIONS. STEP 2: LOCATE THE AREA WHERE THE STOVE IS DESIRED, DETERMINE WHERE THE CEILING JOISTS ARE LOCA- TED AND POSITION YOUR STOVE SO THAT THE CHIMNEY PENETRATION THROUGH THE CEILING AND ROOF WILL BE BETWEEN CEILING JOISTS, MINIMUM CLEARANCES MUST BE MAINTAINED BETWEEN THE STOVE AND ANY COMBUSTIBLE WALL. THE MINIMUM CLEARANCES FROM THE STOVE TO COMBUSTIBLE WALLS ARE SHOWN IN FIGURE 1, PAGE 2, STEP 3: SET YOUR HEARTH EXTENSION AND STOVE IN POSITION, MAKING SURE THE HEARTH EXTENSION EXTENDS 8" FROM THE BACK OF THE STOVE, 18" FROM THE FRONT OF THE STOVE, AND.B" FROM EITHER SIDE, AS SHOWN IN FIGURE 1, PAGE 2. STEP 4: LOCATE THE POSITION OF THE HOLE IN YOUR CEILING AND ROOF BY USING A STRING AND PLUMB-BOB, LINING UP THE PLUMB -BOB WITH THE 8" STACK ON TOP OF THE STOVE. CUT THE HOLES PER THE CHIMNEY MANUFACTURER'S INSTRUCTIONS PROVIDED WITH THE CHIMNEY SYSTEM YOU HAVE SELECTED (ITEM 2). STEP 5: INSTALL THE CHIMNEY SYSTEM (ITEM 2) PER THE CHIMNEY MANUFACTURER'S INSTRUCTIONS. USE ONLY U,L, LISTED, INSULATED CHIMNEY THROUGH THE ATTIC, ROOF OR WITHIN CLOSED AREAS THROUGH TO THE CAP, TO MEET CODE, THE CHIMNEY MUST EXTEND ABOVE THE. ROOF A MINIMUM OF 3 FEET, AND A MINIMUM OF 2 FEET ABOVE ANY AREA OF THE ROOF WITHIN TEN FEET FROM THE PIPE (SEE FIGURE 2, PAGE 2). A 2" CLEAR- ANCE TO ADJACENT COMBUSTIBLES MUST BE MAINTAINED WITH A CLASS A CHIMNEY, STEP 6: INSTALL THE SINGLE WALL PIPE (ITEM 1), MALE END DOWN,' INSIDE THE STOVE STACK, MAINTAINING A MINIMUM CLEARANCE OF 18" TO COMBUSTIBLE MATERIALS, THIS PROCEDURE WILL PREVENT CREOSOTE OR TAR FROM SEEPAGE ON TO THE STOVE SURFACE. IF YOU INTEND TO INSTALL A DAMPER, POSITION THE DAMPER 18" ABOVE YOUR.STOVE, FASTEN EACH PIPE CONNECTION WITH AT LEAST (3) SHEET METAL SCREWS. Page ontrel• Nurlber 54---332 • APPLICATION FOR PERMIT BUILDING DEPARTMENT, CITY of TUKWI LA • 6200 SOUTHCENTER BOULEVARD. TUKWI LA, WASHINGTON 98188 433.1849 RECEv�: ) CITY OF TUK\N'ILA SEP2 le 19 BUILDING DEEM'. DATE 91 6- _ fs .4 . " • i JOB ADDRESS /3173 LEGAL DESCR. LOT NO. BLOCK TRACT ❑ SEE ATTACHED SHEET OWNER f n\ 4 PrIn L I i-YAi 'P4-T i 0 rte PHONE 5 -' c�a ADDRESS i ci 3-0 • • s6 d-L Pi- Su. ZIP CONTRACTOR fZ /3-iii, /F 2 vn itifa PP( PHONE R 5"-i- °0-.45- / ADDRESS 4-13,-2- g. l'79 f{- • ZIP 4'0"1S S' LICENSE NO /9.6 p 4 • 7.y ,. //Y,--' S ST NO. • BUILDING USE TENANT CLASS OF WORK 02 ❑ NEW ADDITION .REMODEL ❑ REPAIR iliOTHER (Specify) BLDG. AREA . 1st FL. 2nd FL. BASEMENT GARAGE DECK, MEZZANINE , # OF STORES TOTAL S.F. VALUATION X PLANNING/ SEPA A• BOND 114 OTHER pi j actl NAME OF APPLICANT (PLEASE PRINT) • . -rpm .D 6i 44 -Vi:--" et././let, c L- 14 I R r4 fN / ti'(k. tm Hs oN /2 y' ADDRESS ,4/S,; 5:c-. _ % 7 f SJ.A'T TA- E `r.f-t it f' • PHONE cc. 5.41 _9 3 I CERTIF.Y THAT THE INFORMATION FURNISHED BY ME IS TRUE AND CORRECT AND THAT THE APPLICABLE CITY OF TUKWILA REQUIREMENTS WILL BE MET. `, ^ iy i SIGNATURE OF APPLICANT' , DO NOT WRITE BELOW THIS LINE . SMOKE ' TYPE CONST. OCC. GROUP OCC. LOAD USE ZONE _ AUTO SPRINKLERS REQ. I DETECTOR • . ❑ YES ❑ NO r YES jJ NO PLAN RVW PLANS: SENT RETURNED APPROVED FEE DISTRIB. BUILDING PLAN RVW. FIRE DEPT. DEMOLITION PLANNING/ SEPA BOND OTHER PUBLIC WKS. TOTAL Bldg. .Div; / COMMENTS: • Amount Date Paid Recei•t 1/' PC:W iii &12 I II I